Loading...
HomeMy WebLinkAbout49863-Z a TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE kyr SOUTHOLD, NY s;s BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49863 Date: 9/20/2023 Permission is hereby granted to: Zuckerman J Livin Trt 1510 E Gillette Dr East Marion, NY 11939 To: install hot tub as applied for. At premises located at: 1510 E Gillette Dr, East Marion SCTM # 473889 Sec/Block/Lot# 38.-3-25 Pursuant to application dated 10/10/2023 and approved by the Building Inspector. To expire on 4/10/2025. Fees: SWIMMING POOLS -IN-GROUND WITH FENCE ENCLOSURE $250.00 CO- SWIMMING POOL $50.00 Total: $300.00 --------------- Buy ding Inspector SWO .. TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 a Telephone (631) 765-1802, Fax (631) 765-9502 lit!ps://www.soi.itholdtow:�n . oar Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only � � � � EC-3 E__�l u PERMIT NO. I "` � Building Inspects 023 Applications and forms must be filled out in their entirety.Incomplete R 5 3L_a3 tions will not be accepted. Where the Applicant Is not the owner,an „ .. . I applications P � �, Pp p P � Owner's Authorization form(Page 2)shall be completed. Date:September 19, 2023 OWNER(S)OF PROPERTY: Name:Joe Zuckerman SCTM#1000-38-03-25 Project Address:1510 E. Gillette Drive East Marion Phone#:1-914-450-0147 A[Email.drz8103@gmail.com Mailing Address:1510 E. Gilletter Drive East Marion CONTACT PERSON: Name:Joan Chambers Mailing Address: PO Box 49 Southold NY 11971 Phone#: 631-294-4241 Emailloanchambers10@gmail.com DESIGN PROFESSIONAL INFORMATION: Name:Lou Schwartz Mailing Address:7 Ridgewood St, Bay Shore, NY 11706 Phone#: (631) 410-6838 Email:tiderunnereng@gmaii.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition WAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Hot Tub, _.. WIII the lot be re-graded? ❑Yes IN No Will excess fill be removed from premises? ❑Yes NNO 1 PROPERTY INFORMATION Existing use of property:R-40 Residence, Intended use of property:same Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? Dyes ❑No IF YES, PROVIDE A COPY. 11 Check Box After Reading: The der/d to nsponsibb for eu drainage and storm v*W bsues a:woad by Chapter 236 of the town Code. APPLICAT110Y IS HEREBY MADE to dee Bugdheg Department for the tssume of a Buildhta Permit pursuant to the Buldheg Zone CrdjrnrKs of tba Town of Southold.Su"lok County,Nm York and other appBrable Jews,ordinarecas or agpdadons.fordo construction at bu0fts% addhlons,atORadon s or for remeoval er donoBtlon as haroim dasaftA The applant agrees to comply with aQ appHadge Mrs,ordinances,building aide, hous ft coda and reguladorm and to admit authorised inspoctors an prranbes and In buH dWWsl for necessary bupecNaes.Fabe statements made heroin are punishable as#Can A ndsderneanor pursuult to Section 210AS of do New Yah State IRMO Law. Application Submitted By(print name):Joan Chambers @Authorized Agent ❑Owner q. v3 Signature of Applicant: -Lo Date: _t STATE OF NEW YORK) SS: COUNTY OF'bk>f-F01 K� ) Joan Chambers being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contracto Agen ,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief, and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this : "O day of�CLEk,no.bCL 20 2-3 otary Public TR"A l "Y L. DWYER NOTARY PUBLIC,STATE OF NEW YORK NO.01 DW6306900 PROPERTY OWNER AUTHORIZATION OQALIFIED IN SUFFOLK COUNTY (Where the applicant is not the owner) C Iv O SIGN EXP ER JUNF-30,2 J` (p Joe Zuckerman residing at 1510 E. Gillette ®rive E. Marion Joan Chambers do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. R • 2( ,23 Own is Signature Date J015 7.v 6FL-Mk(,J Print Owner's Name 2 Q��+a 1NOa-i NI ci QnwvA� lt4ca3 r• d� 'al 31MM � N u ��b• 1 I � � .�^� ,--o� :.may bc.• o i 3 � — �' o� a 1 l . r�L77' f ' lll 11 w �► t — 0 W r . o v - d - -°� � o �s•�r .�� � F � � X z n No i4lorrnaJ a � r N 0 a N .. ��N w a. 1p Id _ LL u w 1A V 3 rq )"I y. aJ Q V Cie M m w -z� 7I r cpog `s = FoI �Q ;z Awa W. wW &( a 41 ° • ` ° oil y� u u e F d 11, Li �4 u�1 30. kf N 64 51 10 E 81 .51 " I I Fff� �18'-81" 3 5'-0.1 I 2 4 I I r- 13'-0a" 3' ZCON " fl 00 IIEW O R SHOWER SHUT OFF z i o i I ° I LL I Z_ '"93`x83"x39'��,..• J I :•.COVERED` ;;, ' � � m ti MASTERSPAS:y,. a;.TWILGHT..7;2;,' I O I Iz I I _ EXIST. ! a EXISTING ONE STORY RESIDENCE STOOP I (LL Q O � W 30 m ''^^• ' m ' co u! NEW STAIRS&RAIL.— co AIL.co cc a f I T r z � EXIST.STOOP ADD NEW COMPOSITE '':•„-"'�� DECKING rn ADD NEW VINYL RAILS u i- ui O I RE..EXIST.STEPS { LU 1 I C E 0 00 I I M �-- ' uj ---._---.._.... .... ... .: ._._ .... .. -. .. � ... ,--EXISTOJGDRIVEWAY Lo N EXISTING STAIRS TO I CELLAR ENTRY I I N z I • I I W I I l l I I I I I NE ' o ' »Das rte' I I NOTE: PROPERTY LINE DIMENSIONS AND HOUSE PLACEMENT I ' TAKEN FROM SURVEY BY ELIZABETH MCKULKIN 2.23.2000 ' LIC. # 050211 I I - - - - - - - - - - - - - - - - - S 64 51 10 W 83. 22 ZUCKERMAN RESIDENCE. . Nw :c w > rn 1510 E. GILLETTE DRIVE EAST MARION c 1000-38.-3-25 J .s+SF �E j •-�r.-..r-.. w,t�-.+i a 4+.a .mac ��';. F ..w+..�-•-•+ d aha- P • , ,/ • A SAFETY INSTRUCTIONS DANGER: DIVING MAY NO DIVIN%3 RESULT IN SERIOUS INJURY OR DEATH. IMPORTANT SAFETY INSTRUCTIONS This spa is not intended for public/commercial use. When installing and using this electrical equipment, basic safety precautions should be observed including the following: READ AND FOLLOW ALL INSTRUCTIONS WARNING —To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. A wire conductor is provided on this unit to connect a minimum 6 AWG (13.302 MM2) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1 .5m) of the unit. (For cord-connected/convertible units) DANGER — Risk of injury. a) Replace damaged cord immediately. ' b) Do not bury cord. c) Connect to a grounded, grounding type receptacle only. (For units intended for indoor use only) WARNING — For indoor use only. This unit is not intended for outdoor use. (For units intended for outdoor use only) WARNING — For outdoor use only. This unit is not intended for indoor use. DO NOT DIVE. 3 p Model Listing Spa Dimensions Electrical Seating Water Capacity Dry Weight Full Weight Therapy Spa Z Number (in./cm) Requirements' Capacity' (gallons/m)' (lbs./kilos), (lbsJkilos)'-•" Pumps Control O TS 240 6200 78"x 78"x 34" Configuration#2 3 20510.78 7151324 2980/1352 2 Icon Spa 199 x 199 x 87 240V, 50A GFCI Touch r Fn TS,6,2 5300 78"x 78"x 34" Configuration#2 5 250/0.95 8401381 3850/1746 2 Icon Spa V1 199 x 189 x 87 240V,.50A GFCI Touch M M TS 67.25 8000 70"x 84"x 34" Configuration#2 5 245/0.93 760/345 3730/1692 2 Icon Spa n 178 x 214 x 87 240V, 50A GFCI Touch TI T517.2 5500 84"x 84"x 38" Configuration#2 6 305/1.15 8971407 4555/2066 2 Icon Spa C'1 214 x 214 x 97 240V, 50A GFCI Touch > TS 7.25 6400 84"x 84"x 38" Configuration#2 7 305/1.15 935/424 4775/2166 2 Icon Spa O 214 x 214 x 97 240V, 50A GFCI Touch Z TS:8.2 5700 94"x 94"x 38" Configuration#2 6 380/1.44 1065/483 5345/2424 2 Icon Spa N 239 x 239 x 97 240V, 50A GFCI" Touch TS 8.25 7700 94"x 94"x 38" Configuration#2 7 395/1.50 1100/499 5690/2581 2 Icon Spa W 239 x 239 x 97 240V, 50A GFCI Touch 'As configured from factory. See appropriate Electrical Requirements section for further details. 'Total bather capacity in spa. The number of bathers in spa should never exceed indicated seating capacity. Depending on spa size, water level and bather displacement; full seating capacity may not be achievable. Do not allow additional bathers to enter if bather displacement results in water levels overflowing or reaching the spa controls (air controls, diverters, spa topside control and etc.) as this will result in water leaking out of the spa shell and potentially in to the equipment area. 'Full weight based on dry weight of spa, max seating capacity of spa, assumed average weight per person of 185 pounds and estimated water weight of 8.34 pounds per gallon. Rounded up in increments of 5. °Manufacturing tolerances along with other factors can result in variance in actual spa weight. If weight is a critical figure necessary for delivery, or final installation, we suggest a minimum of 15% be added to the listed weight when planning delivery or installation. SITE PREPARATION GENERAL GUIDELINES -Spa/Swim Spa Dimension+Minimum Service Clearance Spa/Swim Spa Dimension+Rough Opening *Spa/Swim Spa Dimension T-G"Minimum Service 6"Rough Opening Clearance All Sides Clearance All Sides FRD] Sump pit CY Access/Ventilation AccessNentilation HatchFD Hatch Minimum 3'x 3' Minimum Tx 3' ­ ------- FD =Floor Drain ------- 4-2.- Below Grade Pit/Deck Wall =Access/Ventilation Hatch (Min.3'x3') See"Model Specification"section of Owners Manual for applicable Spa/Swim Spa dimensions. DO NOT DIVE. 40 ELECTRICAL REQUIREMENTS CONFIGURATION 2-240V, 50A GFCI NOTE Electrical requirements by model is shown in Model Specifications.Only electrical configurations pertaining to the models referenced in this manual are shown. ELECTRICAL REQUIREMENTS HAVE YOUR ELECTRICIAN READ THE FOLLOWING INFORMATION BEFORE INSTALLATION BEGINS Electrical connections made improperly,or the use of wire gauge sizes for incurring power which are too small, may continually blow fuses in the electrical equipment box,may damage the internal electrical controls and components, may be unsafe and in any case will void your warranty. It is the responsibility of the spa owner to ensure that electrical connections are made by a qualified electrician in accordance with the National Electrical Code and any local and state electrical codes in force at the time of installation. These connections must be made in accordance with the wiring diagrams found inside the control box.This equipment has been designed to operate on 60Hz.alternating current only,240 volts are required. Make sure that power is not applied while performing any electrical installation.A copper bonding lug has been provided on the electrical equipment pack to allow connection to local ground points.The ground wire must be at least 8 AWG copper wire and must be connected securely to a grounded metal structure such as a metallic cold water pipe.Be sure to have a licensed electrician examine and ensure proper grounding is provided.All Master Spas equipment packs are wired for 240 VAC only.The electrical service for your spa must include a 50 AMP switch or circuit breaker to open all non-grounded supply conductors to comply with section 422-20 of the National Electrical Code.The disconnect must be readily accessible to the spa occupants, but installed at least five feet from the spa. A Ground-Fault Circuit Interrupter(GFCI) must be used to comply with section 680-42 of the National Electrical Code.A ground fault is a current leak from any one of the supply conductors to ground.A GFCI is designed to automatically shut off power to a piece of equipment when a ground fault is detected. Service to the spa must be dedicated 240V, 50A 3 wire plus ground (#6 AWG copper with minimum copper ground sized per NEC and local code requirements). Route service into the equipment area for final hook-up to terminals inside the spa control system.The spa must be hooked up to a"dedicated"240 volt, 50 amp breaker and GFCI.The term "dedicated" means the electrical circuit for the spa is not being used for any other electrical items (patio lights, appliances,garage circuits, etc.). If the spa is connected to a non-dedicated circuit, overloading will result in"nuisance tripping'which requires resetting of the breaker switch at the house electrical panel. 202207 DO NOT DIVE. 41 ' ELECTRICAL REQUIREMENTS CONFIGURATION 2 - 240V, 50A GFCI MAIN ELECTRICAL PANEL _` �• (HOUSE) Key 0 WHT-White Neutral _ 50 � BLK-Black Hot,Line 1 00 e RFD-Red Hot,Line 2 - u GND-Ground .,RFD Y - _ WHr:_"? ='GND - - = BLK SO AMP GFCI =cmc 50A a •.:a :.RED'.., wHT -�._ *SWIM SPA r` CONTROL SYSTEM CONFIGURATION 2 �` ^ _ RED 240V 50A GFCI ® *Refer to wiring diagram ND:; inside swim spa control T; j4 - system for proper power :r connection to terminals. DO NOT DIVE. 42