Loading...
HomeMy WebLinkAbout49847-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY Not W, BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49847 Date: 10/6/2023 Permission is hereby granted to: Kaplan, David 25 Woodgreen Ln East Hills NY 11577 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. At premises located at: 1700 Inlet Way, Southold SCTM # 473889 Sec/Block/Lot# 92.-1-7 Pursuant to application dated 9/19/2023 and approved by the Building Inspector.. To expire on 4/6/2025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 IN"(//" Building Inspector IF , ,a TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 httl2s://'W'W°W.SOLltholdtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only �D PERMIT NO. JKW7_ Building[nspec-tor: SB::u j 9 2023 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building Department Owner's Authorization form(Page 2)shall be completed. Town of Southold Date: OWNER(S)OF PROPERTY: Name: David Kaplan scTM#s000-092.00-01.00-007.000 Project Address:1700 Inlet Way, Southhold, NY 11971 Phone#: 516 680-6850 1 Email:djkaplan@optonline.net Mailing Address: 1700 Inlet Way, Southhold, NY 11971 CONTACT PERSON: Name: Ines Fernandez (EmPower CES, LLC.) Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@empower-solar.com DESIGN PROFESSIONAL INFORMATION: Name: Gregory D. Sachs Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email. permitting@empower-solar.com CONTRACTOR INFORMATION: Name: EmPower CES, LLC.. Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@empower-solar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: IXOther Roof mounted solar panels $30,914.25 Will the lot be re-graded? ❑Yes [XNo Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property: Residential 1 Family Intended use of property: Residential 1 Family Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑YesXNo IF YES, PROVIDE A COPY. IN Check Box AfterReading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name : Ines Fernandez C4Authorized Agent ❑Owner Signature of Applicant: Date: ps) Z3 STATE OF NEW YORK) SS: COUNTY OF ) Ines Fernandez being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Ryan M.Moser of 20 Z3 da sIn NagsAll --h' y NOTARY Re strati n No.STATE OF NEW YORK 01M06412506 OOmmissi ftpPW0Hr-nber 28,2024 PROPERTY I (Where the applicant is not the owner) I, David Kaplan residing at 1700 Inlet Way, Southhold, NY 11971 do hereby authorize Ines Fernandez to apply on my behalf to t 'TI'of Southold Building Department for approval as described herein. J23 O ignature Date vI — 4—'La— 1-� Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 " ro err southuoldtownn ov — seand southoldtownn . ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/11/2022 Company Name: EmPower CES, LLC. Name: Timoth" Crotty License No.: ME-65990 email: permi,tting@emp,ower-solar.com Address: 4589 Austin Blvd,, Island Park., NY 11558 Phone No.: (516)-544-4592 JOB SITE INFORMATION (All Information Required) Name: David Kaplan Address: 1700 Inlet Way, Southhold NY 11971 Cross Street: Phone No.: (516) 680-6850 Bldg.Permit#: email:d'ka lan o tonline.net Tax Map District: 1000 Section:092.00 Block: 01.00 Lot: 007.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of roof mounted solar panels 26 SPR-400w ACPV modules 10.40kW totals stem size Circle All That Apply: Is job ready for inspection?: YES / Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Formals SURVEY OF PROPERTY CEDAR POINT DRIVE EAST SITUATED AT BAYVIEW TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-92-01-07 SCALE 1"=20' NOVEMBER 15, 2006 AUGUST 24, 2021 UPDATE SURVEY AND ADD PROPOSED ADDITIONS AREA = 16,744 aq. f6 - DO M UNE) D.384 cc. 1T IV W CERT7FfED TO. y BARBARA ANN KAPLAN BARBARA ANN KAPLAN. AS TRUSTEE OF THE TRUST AGREEMENT DATED MAY 15, 1986 - '•:,- KNOWN AS THE ROBERT AND BARBARA KAPLAN PERSONAL RESIDENCE TRUST No. 1 4. LOT NUMBERS SHOWN REFER TO MAP Na. 1 OF EDWIN H. BROWN, FILLED - IN THE OFFICE OF THE CLERK OF SUFFOLK COUNTY AS MAP No. 802 AND TO MAP OF CEDAR BEACH PARK, FILLED - - IN THE OFFICE OF THE CLERK OF SUFFOLK COUNTY AS MAP No. 90 es ¢ 1 ✓-X I 41 I for ,5 I ?I C1 90 r I I N 74.0, aY T 127.39, r = rE->f 1 sasa7 E �A y Nathan Taft Corwin III W-7 Land Surveyor 5u Te$lonl J.b ,JJ,LS. A. m L ' PPRP Fice rxP saroy,—suneP;Pbv—SN. nPP,— CePP0ve6PP La w PHONE(971)727-2080 Foc(631)727-1727 m IP.� yg 017KY7 IDGiED A7 NVUNO A90RF55 1599 N. 9vcd PA.Box 19 T d, Jameaparl,Nn Yark 119!7 Jnmmparl,Nn YaA 11917 E-YW:NConInJOod.com voRK Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured EMPOWER CES LLC DBA EMPOWER SOLAR 310-534-7994 4589 AUSTIN BOULEVARD ISLAND PARK,NY 11558 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 522407627 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 54375 ROUTE 25 3b.Policy Number of Entity Listed in Box"1 a" SOUTHOLD, NY 11971 DBL252634 3c.Policy effective period 05/10/2023 to 05/09/2024 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. B.Disability benefits only. E] C.Paid family leave benefits only. 5. Policy covers: ❑X A.All of the employers employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employers employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 5/12/2023 By hf (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 4B,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees, Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note;Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-1120.1 (12-21) 111111111 1111111 NYSIF PO Box 66699,Albany,NY 12206 New York State Insurance Fund nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE A A A A A A 522407627 r �... AMWINS BROKERAGE OF NEW YORK 200 ELWOOD DAVIS ROAD I' SUITE 200 LIVERPOOL NY 13088 '" µ SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER EMPOWER CES LLC TOWN OF SOUTHOLD 4589 AUSTIN BLVD 54375 ROUTE 25 ISLAND PARK NY 11558 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2546 624-4 256986 05/01/2023 TO 05/01/2024 04/25/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2546 624-4, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY AFFORDS COVERAGE TO THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. DAVID SCHIEREN GREG SACHS EMPOWER CES LLC THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,[ SURANCE FUND UNDERWRITING VALIDATION NUMBER: 1057999100 IUI1��1IRMO,0l0000N0B00011483569111�1�1u� �II� Form WC-CERT-NOPRINT Version 3(08/29/2019)[WC Policy-25466244] U-26.3 69 [00000000000114835691][0001-000025466244][##Z][16124-21][Cer NoP-CERT 1][01-00001] EMPOCES-01 TKARUN DATE(MMIDDIYYYY) CERTIFICATE OF LIABILITY INSURANCE 5/8/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. _ IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0757776 c AC'T Ana Bello HUB International Insurance Services Inc. mm ................._ _. 600 Corporate Pointe �1 N,,Ext )568-5977 Suite 600 � 11uIbinlerna Iona/Corn ana Bello , _ .................�.�.��� ....._. ..... �. Culver City,CA 90230 ._....... j1utVRER.(�1AFFORDING COVERAGE ......._� � _: rO......� INSURERA-Southwest Marine&General Insurance COm n 12294 INSURED � ................................ ._........m....� ...........m............_.. - ... INsuRER B JamesIT River Insurance Companymmmmmmmmmmmm 12203 EmPower CES LLC „INSURER C: 4589 Austin Boulevard INSURER D". Island Park,NY 11558 INSURER E; _ INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION'NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADOL.SUER POLICY EFF POLICY EXP TYPE OF INSURANCE POLICY NUMBER LIMITS A X COMMERCIAL GENERAL LIABILITY 1,000,000 _ EACH OCCURRENCE � CLAIMS-MADE X OCCUR PK202300006109 5/4/2023 5/4/2024 DAMAGE TO RENTED 500,000 �.__ .... X MED EX,P An..one mersan $ 10,000 _...m PERSONAL&ADV INJURY. $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE, $ 2,000,000 �]P PODUCTSITIT M 2,,000,001 POLICY LOC OEP_ PER PROJECT AGG 5000,000 rR $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT ANY AUTO BODILY INJURY OWNED SCHEDULED AUTOS ONLY AUTOS BODILYINJURY Per acGdent $ ......., AUT OS ONLY AT .b "ieeOcEr..IR .rI AMA $ .. 000 5, 000 B UMBRELLALIAB OCCUR EACH OCCURRENCE ,$ ......,,. .................... „ ... X Excess UAB ', X CLAIMS-MADE 001306871 5/4/2023 5/4/2024 AGGREGATE $ 5,000 00000 . -DED.............m.. RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY YIN T..� - R__ --- � ANY PROPRIETOR/PARTNERIEXECUTIVE ❑ NIA E.l.EACH ACCIDENT $ WPNCERlUVVE:MBER EXCLUDED? ._.... andatory in NH) E,L DISEASE EA EMPLOYE $ If yes describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT .$ DESCRIPTION OF OPERATIONS.P LOCATIONS I VEHICLES (ACORD 101,AddIllonal Remarks Schod'ulle may be attached It more aca Is.required) The certificate holder is listed as additional insured per attached endorsements 620100413&#CG20�70413 CERTIFICATE,HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Town ACCORDANCE WITH THE POLICY PROVISIONS. Route Southold Southold,NY 11971 AUTHORIZED REPRESENTATIVE Av ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Pb Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name GREGORY SACHS R Business Name s certifies that the firer is duly licensed, EMPOWER CES LLC DBA :he County of suffolk License Number: H-50211 Rosalie Drago Issued: 05/30/2012 Corrin issioner Expires: 5/1/2024 Suffolk County Dept.of Labor,Licensing&Consumer Affairs i MASTER ELECTRICAL LICENSE Name TIMOTHY M GROTTY Business Name This certifies that the Empower CES LLC DBA nearer is duly licensed :,y the County of suffDlk License Number:ME-65990 Rosalie Drago Issued: 11/12/2021 Commissioner Expires: 11/01/2023 C z-l-I QCS mss 043 Gregory Sachs, PE 4589 Austin Blvd, (516)-544-4115 Island Park, NY 11558 permitting@empower-solar.com September 8, 2023 To Whom It May Concern: The purpose of this letter is to certify that the existing roof structure located at: 1700 INLET WAY,SOUTHHOLD, NY 11971 can support the additional load of the solar energy system, in addition to wind,snow and gravity. Portions of roof structure covered and not covered with photovoltaic panels are in compliance with R324.4.1.1. Furthermore, it has been determined that the structure complies with the 2020 Residential Code of New York State including the ASCE 7. Please see Table 1 below for specific data relating to the calculations for each roof structure involved in the solar energy system installation. Table 1 Rafter Snow Wind Span Layers of Roof Surface Maxx S spacing Cross Section Load Speed Kneewall Collar Ties Shingles (in) (psf) (mph) Flat 1 21.00 16 Nominal 2x12 20 130 No No 1 Sincerely, Gregory Sachs, PE y N E VV D. Sq �� N U (D O PROFESS�O� 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 o TEL:516-837-3459 RESIDENTIAL wwFAX:516-706-1789 w empower-solar.com H SOLAR PROJECT THEINFORMFEMPOWERCE.LLC UNNi THESOLE H PROPER DUCTIONO R DISTRIBUTION IST•LLC ION OF THIS ED REPROOU PRODUCTION OR OISTRI PROHIBITED OF THIS PROJECT TEAM. PRIOMATER SPECIS STRFIC CTLRITTE PERMISSION N PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL S OWNER: David Kaplan G G OF Q' CORY PHONE: (516)680-6850 ENGINEER OF RECORD: r C7 " s" _ _N a. F SOLAR INSTALLER: GREGORY SACHS,PE EMPOWER SOLAR m r - 4589 AUSTIN BLVD 2� 4589 AUSTIN BLVD ISLAND PARK,NY 11558 X34 5 3, ISLAND PARK,NY 11558 - PHONE:516-837-3459 110 064 E PHONE:516-837-3459 E e D REV: DESCRIPTION: DATE: f'l PROJECT LOCATION DATA: SHEET INDEX: PROJECT NAME: David Kaplan - ADDRESS:1700 Inlet Way,Southhold, ST-01 COVER SHEET ''• NY 11971 S-01 EQUIPMENT LOCATIONS S-02 STRUCTURAL PROJECT LOCATION: C SE-01 ELECTRICAL C 1700 Inlet Way,Southhold, NY 11971 SCTM:1000-092.00-01.00-007.000 PROJECT# - _•w - _r PROJ. PHASE: PERMIT DAT8/30/2023 B i - - - I B DESIGNED BY: ED CHECKED BY: GS SCALE: NTS MAP TITLE COVERSHEET A A SHEET: ST-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 " EMPOWER SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 o TEL:516-837-3459 FAX:516-706-1789 www.em power-s o ar.com SETBACK LEGEND ® THE INFORWTION DISCLOSED HEREIN IS THE SOLE H H PR OPERTYOFEMPCWER CES,LLC.UNAUTHORD:ED 36"CLEAR PATH z REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION T PROFESSIONAL SEAL 5 ® 18"RIDGE SETBACK 1 ' 1 i G 4 G ® ACCESS ROOF � ,� G� 2 C,l GORY S J- �. F O FLAT-1 ROOF: _ F 3 26 SUNPOWER 400W-ACPV-(WAR)PANELS Z TOTAL POWER: 10.40 kW N _ ORIENTATION:157°;PITCH:0° �O — O O O O TYPE 2:ROOFTECH `+ Aa SOLAR ACCESS:97°/D SSION�� E IIIIIHITIllO TSRF:81 E I i I i DRIVE WAY D REV: DESCRIPTION: DATE: m 0 —_ —_ PROJECT NAME: EQUIPMENT LEGEND: KAPLAN RESIDENCE 1 ia[iJ MODULES PROJECT LOCATION: C OO C 1700 INLET WAY SOUTHHOLD,NY 11971 UTILITY METER(EXTERIOR WALL) PROJECT# PROJ.PHASE: PERMIT 3❑ INVERTERS DATE: 09!0872023 DATE: B DESIGNED BY: ED CHECKED BY: GS 41 SOLAR DISCONNECT(EXTERIOR WALL) SCALE: NTS TITLE: 51 MAIN SERVICE PANEL(INTERIOR WALL) EQUIPMENT LOCATIONS A ROOF LAYOUT A NOT TO SCALE SHEET: S-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER S O L A R 4589 AUSTIN BLVD SUNPOWER MODULES ISLAND PARK,NY 11558 o ON INVISIMOUNT RACKING TEL:516-837-3459 FAX:516-706-1789 SHINGLES www.empower-soiar.cDm THE INFORMATION DISCLOSED HEREIN IS THE SOLE H RAFTERS H PROPER Y OFEMPOWERCES.LLC.UNAUTHORQED REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL S G G NF * �GORY� m F TYPICAL ROOF SECTION P N NOT TO SCALE SUNPOWER PANEL SPECS � n?�53 1 E MODULE POWER(Wdc) QTY MODEL# LENGTH WIDTH DEPTH WEIGHT TABLE S-1.1:MAX.ATTACHMENT SPACING E �SSIONP& SPR-400 26 SPR-M-SERIES-AC 73.7" 40.6" 1.57" 48.0 LB PORTRAIT: 5'-4" LANDSCAPE: SPR-A-SERIES-AC 72.2" 40.0" 1.57" 46.5 LB SPR-E/X-SERIES-AC 61.4" 41.2" 1.81" 42.9 LB D REV: DESCRIPTION: DATE: NOTES: PROJECT NAME 1. TOTAL SYSTEM DC POWER:10.40 kW David Kaplan 2.RACKING SYSTEM INSTALLED IN ACCORDANCE WITH CODE-COMPLIANT INSTALLATION MANUAL 3.ATTACHMENTS TO BE SECURED TO ROOF ASSEMBLY USING 5 mm STAINLESS STEEL SCREWS PROJECT LOCATION: AND/OR 5/16"STAINLESS STEEL LAG BOLTS SPACED ACCORDING TO TABLE S-1.1 C 1700 Inlet Way,Southhold, 4. ALL ATTACHMENTS TO ROOF, MOUNTING BRACKETS & HARDWARE MEET OR EXCEED NYS NY 11971 CODE REQUIREMENTS 5.INSTALLATION TYPICALLY MAINTAINS 7/8 INCH SPACING BETWEEN MODULES 6.SIZES OF STRUCTURAL MEMBERS THAT WERE NOT ACCESSIBLE FOR DIRECT MEASUREMENT PROJECT# ARE BASED ON OBSERVATIONS OF ACCESSIBLE MEMBERS, CONSTRUCTION DEPTH OR PROD.PHASE: PERMIT BOTH IN ADDITION TO KNOWLEDGE OF STANDARD CONSTRUCTION PRACTICES AT THE DATE: 8/30/2023 B B DESIGNED TIME OF CONSTRUCTION 7. THIS DOCUMENT CERTIFIES THAT THE ROOF STRUCTURE HAS BEEN CHECKED FOR WIND, CHECKED BYY:: GS ED SNOW, UNBALANCED SNOW, LIVE AND DEAD LOADS BASED ON ASCE 7-10 CHAPTER 30 - SCALE: NTs TITLe: WIND LOADS - COMPONENTS AND CLADDING (C&C) AND FOR CONFORMANCE WITH THE 2020 RESIDENTIAL CODE OF NEW YORK STATE.THIS CERTIFICATION DOES NOT APPLY TO STRUCTURAL ANY ADDITIONAL ROOF ALTERATIONS AFTER THE DESCRIBED INSTALLATION A 8.THIS ROOF STRUCTURE AS SHOWN IS ADEQUATE TO SUPPORT THE PROPOSED LOADS A SHEET: 9.REFER TO STRUCTURAL LETTER FOR SITE SPECIFIC AND ROOF SURFACE DATA S-02 1 2 3 4 1 5 1 6 I 7 I 8 9 10 11 12 13 I 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER NOTES: 1 S O L A R 4589 AUSTIN BLVD ISLAND PARK,NY 11558 0 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR TEL:516-837-3459 ELECTRIC SYSTEM) FAX:516-706-1789 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN www.empower-salar.com STANDARD INVERTER ASSEMBLY: SERVICE PANEL USING'SPLIT-BOLT CONNECTOR' THE INFORMATION DISCLOSED HEREIN IS THE SOLE H3. IN SOME CASES POWER FOR DATA MONITORING ENCLOSURE MAYBE H PROPER YOF EMPOWER CES,LLC.UNAUTHORRED REPRODUCTION OR DISTRIBUTION OF THIS DERIVED FROM MAIN SERVICE PANEL MAT ERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION 4.CONNECT UTILITY SIDE TO PANEL LUGS PROFESSIONAL SEAL 5.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 6.SIZE GEC AND EGC AS PER NEC 250.66,NEC 250.122 RESPECTIVELY 7.PROTECT GEC AND EGC SUBJECT TO PHYSICAL DAMAGE AS PER NEC G SOLAR 250.64(B),NEC 250.120(C) G 1 8.FINAL SCHEMATIC SPECIFIC TO THIS INSTALLATION AVAILABLE UPON -( N ARRAY /1 REQUEST (.0GORy O INVERTERS AC ( ) DISCONNECT 0 Fn Ln 5 31 E E STANDARD EXTERIOR INTERCONNECTION: STANDARD INTERIOR INTERCONNECTION: D REV: DESCRIPTION: DATE: D PROJECT NAME: INTERIOR EXTERIOR INTERIOR EXTERIOR David Kaplan PROJECT LOCATION: 1700 Inlet Way,Southhold, C TAP MAIN MAIN NY 11971 SERVICE ENCLOSURE O 1 PANELETTE SERVICE M PANEL PANEL PROJECT#.. UTILITY UTILITY PROJ.PHASE: PERMIT METER METER DATE: 8/30/2023 B DESIGNED BY: ED B CHECKED BY: GS 1 SCALE: NTS TITLE: ELECTRICAL A A SHEET: SE-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 UTILITY EMPOWER METER S O L A R O AUSTIN BLVD ISLANDAND PARK,NY 11558 o TO TEL:516-837-3459 UTILITY FAX:516-706-1789 GRID w w.em p o w e r-s oIar.com BRANCH C BRANCH B BRANCH A (7)SPR-40OW MODULES (9)SPR-40OW MODULES (10)SPR-40OW MODULES THE INFORMATION DISCLOSED HEREIN IS THESOLE H TOTAL DC STC POWER:2.80 kW TOTAL DC STC POWER:3.60 kW TOTAL DC STC POWER:4.0 kW H REPRODUCTIONO R DISTRIBUTION AN OF IS ENPHASE IQ7HS-66 MICRO INV 9 ENPHASE IQ7HS-66 MICRO INV 10 ENPHASE IO7HS-66 MICRO INV JLI REPRODUCTION OR DISTRIBUTION IT THIS (7) () ( ) MATERIAL IS STRICTLY PROHIBITED WITHOUT TOTAL AC POWER:2.688 kW TOTAL AC POWER:3.456 kW TOTAL AC POWER:3.84 kW AC4 PRIOR SPECIFIC WRITT PERMISSION PROFESSIO S CONTINUE AS CONTINUE AS CONTINUE AS REQUIRED FOR INV.... REQUIRED FOR INV.... REQUIRED FOR INV....SPECIFIED STRINGING SPECIFIED STRINGING SPECIFIED STRINGING GAC1 AC1 AC1 G O N�fw_(1)SPR-0OOW MODULE (1)SPR40OW MODULE (1)SPR400W MODULE TO(1)ENPHASE MICRO INV. INV.2 (1)ENPHASE MICRO INV. INV.2 (1)ENPHASE MICRO INV. INV.2HOUSELOADS ACI AC1 AC1 F F yW (1)SPR-40OW MODULE (1)SPR-40OW MODULE (1)SPR-40OW MODULE (1)ENPHASE MICRO INV. INV.1 (1)ENPHASE MICRO INV. INV.1 (1)ENPHASE MICRO INV. INV.1 _-"4-•`= t(/ MAIN SERVICE PANEL G•�� 3 AC1 AC1 AC1 1 -PHASE 120/240V _ 1 ��SS10NP� E SUNPOWER E DATA AC DISCONNEC- MONITORING ' 60A,2P CB LABEL DESCRIPTION LABEL DESCRIPTION L1 L2 N AC1 SPR AC CABLE AC2 1"PVC n G 15A,2P CB (2)#12 AWG (6)#10 AWG D REV: DESCRIPTION: DATE: D (1)#10 AWG,EGC n 20A,2P CB G AC3 PROJECT NAME: AC3 3/4"PVC AC4 1 1/4"PVC TO RACKING (3)#10 AWG (3)#6 AWG GROUND NEMA 3R n 20A,2P CB KAPLAN RESIDENCE (1)#10 AWG,EGC (1)#4 AWG,GEC (1)#6 AWG, EGC ENCLOSURE r^, 20A,2P CB PROJECT LOCATION: C C 1700 INLET WAY SOUTHOLD,NY 11971 AC2 PROJECT1k PROJ.PHASE: PERMIT DATE: 09/08/2022 NOTES: B B DESIGNED BY: IV 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR ELECTRIC SYSTEM) CHECKED BY: XX 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN SERVICE PANEL USING IRREVERSIBLE SPLICE 3.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 1 Li NTS 4.SIZE GEC AND EGC AS PER NEC 240.66,NEC240.122 RESPECTIVELY TITLE: 5.USE MC ONLY IF INCLUDED GEC IS ADEQUATELY SIZED. THREE LINE AC COMBINING MLO PANEL ELECTRICAL SCHEMATIC TOTAL SYSTEM SIZE: 10.40 kW 1 -PHASE 120/240V A A (26)SPR-40OW MODULES SHEET: (26)ENPHASE IQ7HS-66 MICRO-INV. SE-02 1 2 3 4 5 6 7 8 9 10 11 12 13 ARM SERIES AREE WSMDi-395 to WSIVIDi-415 one with the Sun riBRFYA4 �� y/ Highest reliability& Better performance Split junction box Reduced power PID resistant Sustain heavy M6 Mono enhanced crack under all losses up to with long wind&snow loads PERC cells tolerant 9BB climatic conditions 114 times term reliability (2400 pa&5400 pa) module 14 VARIATION WITH IRRADIANCE Celli temp.•25•C tz mcweSt lmad.-f000 wm,• oB2w 10 Inctlenl Iniad.•am mw320 e - Ir,cWem lmd.-600 W]me 2�3 IncWeN irad.-dpp W/m* 15B.9W Inctlenl Iniad+200- ]].]W 1 °B ,o zo Bo do so voles m A®V VARIATION WITH TEMPERATURE E9 s - IBCNan,In-d..,BOB W/m• Pm -CeY.lemp-25 C,Pmpp+dB0.2 W Pmee-0]e.d w 2 Ceaf PmOB-303.0W 0 10 20 BB dY BO vo e9em The Graphs are for reference purpose only.Please consuh Waares technical team for further clarifications. maw aaAow INTERNATIONAL & ®Linear Performance Wan-anty stasw -- ❑Standard Performance Warranty NATIONAL CERTIFICATIONS " IEC 61215 I IEC 61730 UL61730 9 IEC TS 62804-1 ( c E LISTED g 5 it a/ ISO 9001:2015 1 ISO 14001:2015 1 ISO 45001:2018 Independent assessment of factories by BLACK&VEATCH www.waaree.com r ARKA SERIES IMAREE WSMDi-395 to WSIVIDi-415 One with the Sun ELECTRICAL CHARACTERISTICS Pmax(W) Vmp(VI Imp(A) Isc(A) Voc IV]Models Module Eff.(a/o) STC I NOCT STC NOCT STC NOCT STC NOCT STC I NOCT WSMD-395 395 296.8 37.77 34.70 10.47 8.55 11.24 9.08 45.00 42.10 19.78 WSMD-400 400 300.6 38.00 34.90 10.54 . 8.62 11.32 9.14 45.22 42.30 20.03 WSMD-405 405 304.4 38.22 35.10 10.61 8.66 11.40 9.21 45.44 42.50 20.28 WSMD-410 410 30B.2 38.44 35.30 10.68 8.74 11.48 9.27 45766 42.70 20.53 WSMD-415 415 312.1 1 38.66 1 35.40 1 10.75 8,81 1 11.57 1 9.34 1 45.88 42.90 20.78 'StandardTest Conditions(SIC)-1000 Wlm2 irradiance,Air Mass 1.5 and 25'13cell temperature.Nominal Operating Cell Temperature MOM-B00 W/m2 irradiance,-hr Mass 1.5,Ambient temperature 20'C and Wind speed 1 mis. Average power reduction of 4.5%at 200'Nfm2 as per IEC 60904-1.Measuring Uncertainty±3yo. System Voltage 1 1500 V Series Fuse Rating 22 A I MECHANICAL CHARACTERISTICS Length x Width x Thickness(L x W x Tl 1924 mm W x 1038 mm(W)x 35 mm(T) Weight 22 kgs Solar Cells per Module(Units)/Arrangement 132 cells/(11x6 I I 110 Solar Cell Type&Size Mono PERC,83 x 166 mm Front Glass 3.2 mm Low Iron and Tempered glass with ARC coating Encapsulate PID Free&UV Resistant Junction Box(Protection degree/Material l IP6B/Weatherproof PPO Cable&Connector(Protection degree/Type) IP6B rated/Staubli MC4 Connector Cable cross-section&Length 4 mm'&1200mm Frame Anodized Aluminium Alloy,Anodization thickness>_15 micron Fire rating Type 2 DESIGN SPECIFICATIONS I THERMAL CHARACTERISTICS Temperature coefficient of Current(Iscl,a(a/o/°Cl 0.055 g jl r} Temperature coefficient of Voltage(Voc),B Rlaffl -0.285 Temperature coefficient of Power(Pm),y(a/a/°Cl -0.365 I a NOCT(°Cl 43±2 s� I s= Operating temperature range('M -40 to 85 I la 1349AT1.00 40pD�100 I Waaree Energies Ltd.is amongst the top Solar Energy Companies and has the I I j country's largest Solar PV Module manufacturing capacity of 5 GW.In addition,it I `• 6 is committed to provide top notch EPC services,project development,rooftop j solutions,solar water pumps and also in an Independent Power Producer.Waaree has its presence in over 325+locations nationally and 68 countries globally. ' =o- \ If you need specific product certificates.and if module installations are to deviate from our guidance specified in our installation manual,please contact your local Waaree sales and technical representatives. 12 Years Product Warranty •27 Years Power Output Warranty •The electrical data given here is for reference purpose only. •Please confirm your exact requirements with the sales representative while placing your order. •Refer installation Manual instructionsS,Waaree warranty statement for terms&conditions. •Mares Reserves the rightto change the specifications without prior notice.z Www.waaree.corn WEUE&PD/395-415/132/MP/HC/CMZ/01/27.07.2022 Data Sheet Enphase Microinverters Pegion:AMEP,ICAS Enphase 1W7HS The high-powered smart grid-ready ic vertex Enphase IQ7EIS Micro inverter"' with integrated MC4 connectors dramatically simplify the installation process while achieving the highest system efficiency. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved,lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014,2017&2020) Efficient and Reliable "r/ i I - Optimized for high powered 66-cell*modules L: Highest CEC efficiency of 97.0% More than a million hours of testing ENPHASE0 Class II double-insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support,voltage and frequency - ride-through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) The IQ7HS is required to support 66-cell modules. To learn more about Enphase offerings,visit enphase.com EN HAS Enphase OQ7HS Micr®inverter INPUT DATA(DC) _ o _. IQ7HS-66-M-US �` �____ Commonly used module pam gs'rt 320 W-460 W+ Module compatibility 66-cell PV modules Maximum input DC voltage 59V Peak power tracking voltage 38 V-43 V Operating range 20 V-59 V Min/Max start voltage 30 V/59 V Max DC short circuit current(module Isc) 15A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTOUTDATA(AC) @240 VAC @208 VAC Peak output power 384 VA 369 VA Maximum continuous output power 384 VA 369 VA Nominal(L-L)voltage/rangez 240 V/211-264 V 208 V/183-229 V Maximum continuous output current 1.60 A(240V) 1.77 A(208V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 to 68 Hz 47 to 68 Hz AC short circuit fault current over 3 cycles 4-82A 4.82 A Maximum units per 20 A(L-L)branch circuit3 10 9 Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V CEC weighted efficiency 97.0% 96.5% MECHANICAL DATA Ambient temperature range _ -40°C to+60°C _ Relative humidity range 4%to 100%(condensing) Connector type Staubli made MC4 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 J Enclosure Class II,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA type 6/outdoor Altitude 2000m _ FEATURES Communication --_ -- Power Line Communication(PLC) Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. Compliance CA Rule 21 (UL 1741-SA),HECO v1.1 UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEG-2014,NEC- 2017 section 690.12,NEC 2020 and C22.1-2015 Rule 64=218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https7//`eni3hase.com/en-us/supi)ortZmodLile-comipatibiliiy. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com CO 2022 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc E P H A S 10-18-2022 �� Simple and Fast Installation - • Integrated module-to-rail grounding �"'•``�'� ��"�,' - . - G Pre-assembled mid and end clamps f Levitating mid clamp for easy placement Mid clamp width facilitates consistent,even - i -`_< module spacing UL 2703 Listed integrated grounding - Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait with up to 8' rail span Pre-drilled rails and rail splice Rails enable easy obstacle management Customer-Preferred Aesthetics #1 module and#1 mounting aesthetics Elegant Simplicity Best-in-class system aesthetics Premium,low-profile design SunPower' InvisiMountT" is a SunPower-designed Black anodized components rail-based mounting system.The InvisiMount system Hidden mid clamps and new capped,flush addresses residential sloped roofs and combines faster end clamps installation time, design flexibility, and superior aesthetics. Part of Superior System The InvisiMount product was specifically envisioned and Built for use with SunPower DC and AC modules engineered to pair with SunPower modules.The resulting Best-in-class system reliability and aesthetics New optional rooftop transition flashing, rail- system-level approach amplifies the aesthetic and mounted J-box,and wire management rail clips installation benefits—for homeowners and for installers. Combine with SunPower modules and SunPower EnergyLink monitoring app sunpower.com ;����, _Ill�f11111�►fiEllE��lllrllil_:_- ,r C r', i )�J Datasheet • i ® i 0 Jill Module'/Mid Clamp and Rail Module'/End Clamp and Rail t..» Mid Clamp End Clamp Rail 8 Rail Splice Ground Lug Assembly(for DC slysrems only) AMA moo �.ars ,u. 6.r� op,• ��a8°t m 'n'g"g c a F r.�� 'a n a r ,g s si�•�°r,�4, - Mid Clamp Black oxide stainless steel 300 series 63 s(2.2 oz) Temperature i -40°C to 90`C(-40°F to i 94'F) End Clamp Black anodized aluminum 6000 ser:es 110 g(3.88 oz) i Max.i.oad(LRFD) � ' 3000 Pa uplift Rail Black anodized aluminum 6000 series 830&'m(9 oz/ft) I 6000 Pa downforce Rall Splice Aluminum alloy 6000 series 830 g/m(9 oz/ft) j Ground Lug 304 sta-nless steel Go.S g/n.I(3.75 oz) Assembly (A2-70 bolt:un-plated copper lug) Composition Shingle Rafter Attacnment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile RoofAttachment Universal iiterface for other roof attachments • � 1. � 6 3@, m wed :�o e . Uplift 664 Ibf I,1id Clamp ' Shear 5401bf e v " �4y " Uplift 899 Ibf 25-year product warranty End Clamp Warranties Shear ZZO Ibf i 5-year finish`.n`arranty Moment-upward 548 Ibf-ft � Pall I UL 2703 Listed 7 moment:downward 580 Ibf-ft Certifications I Class A Fire Rated Moment.upward 548 Ibf-ft - Rail Splice Moment:downward 580 Ibf-ft Uplift 1000 Ibf L-foot Shear 390 Ibf Refer to roof attachment hardware manufacturer's documentation. Module frame that is compatible with the InvisiMount system required for hardware interoperability. 2 SunPovver recommends that all Equinox"',InvisiMount'",and AC module systems always be designed using the SunPower Design Tool.If a designer decides to instead use the component capacities listed in this document to design a system,note that the capacities shovvn are Load and Resistance Factor Design(LRFD) design loads,and are NOT to be used for Allowable Stress Design(ASD)calculations;and that a licensed Professional Engineer(PE)must then stamp all calculations. Should you have any questions please contact SunPower Technical Support at 1-800-SUNPOWER(1-800-786-7693). sunpower.com ,D 2017 SunPower Corporation.All R oats Reserved.SUNPCtAVEP„the SUNPOVVER logo,En,.:INO/,and INVISINICUNT are trademarks or registered trademark=-of SunPcr•ef Corporation. 509506 RevE All other trademarks are the Property of their respective owners Specifications included in this datasheet are subject to change without notice. D.