Loading...
HomeMy WebLinkAbout48734-Z S1)FFOtX� Town of Southold 8/5/2023 P.O.Box 1179 o _ j? 53095 Main Rd 4,j �ao�rf Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44403 Date: 8/5/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 680 Private Rd 47,East Marion SCTM#: 473889 Sec/Block/Lot: 38.-1-28 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/28/2022 pursuant to which Building Permit No. 48734 dated 1/13/2023 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to an existing single family dwelling as applied for. The certificate is issued to Wills,Brian&Jaye of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48734 5/31/2023 PLUMBERS CERTIFICATION DATED f A or ed ig afore �o�suFFoc o TOWN OF SOUTHOLD a Kco�� BUILDING DEPARTMENT H z TOWN CLERKS OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48734 Date: 1/13/2023 Permission is hereby granted to: Wills, Brian 680 Private Rd #7 East Marion, NY 11939 To: Install roof mounted solar panels to an existing single family dwelling as applied for per manufacturers specifications. At premises located at: 680 Private Rd #7, East Marion SCTM #473889 Sec/Block/Lot# 38.-1-28 Pursuant to application dated 11/28/2022 and approved by the Building Inspector. To expire on 7/14/2024. Fees: SOLAR PANELS $50.00 CO-RESIDENTIAL $50.00 ELECTRIC $100.00 Total: $200.00 Building Inspector so�ryol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlina-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Brian Wills Address: 680 Private Rd #7 city:East Marion st: NY zip: 11939 Building Permit#: 48734 Section: 38 Block: 1 Lot: 28 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Empower Solar License No: 65990ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency StrobeHeat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 8.715kW Roof Mounted PV Solar Energy System w/ (21) Sunpower415W Modules, Combiner Panel 70A w/220x4, SunPower Monitor Notes: Solar Inspector Signature: Date: May 31, 2023 S.Devlin-Cert Electrical Compliance Form OF 50UTyo - - - -----—__ - * # TOWN OF OUTHOLD BUILDI DEPT. `yco 631-765-1.802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR OF SOUIyOlo f # TOWN OF SOUTHOLD BUILDING DEPT. °`y�nurm 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 5vJW [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]' RENTAL REMARKS: �06/ \ L)L/ DATE 3431INSPECTOR Gregory Sachs, PE 4589 Austin Blvd., Island (516)-544-4592 Park, NY 11558 permitting@empower-solar.com June 12th, 2023 } sv { Town of Southold `", ' ` r~• Building Department artment 1 � � 54375 Route 25 Southold, NY 11971 JUN 20 2023 Permit#:48734 680 Private Road 7 East Marion, NY ` Section:038.00 Block:01.00 Lot: 028.000 To Whom It May Concern: The Solar Electric installation at 680 Private Road 7, East Marion, NY 11939 (Wills Residence) has been inspected and meets the New York State Building Code standards for construction and the provisions of ASCE 7.The solar panels have been secured to the roof as per the manufacturer's attachment detail shown on the approved drawings, and are in compliance with the structural engineer's.requirements.The project is consistent with the specifications set forth in the permit application. Sincerely, YORK SAC 0 o�f� _ . to /CENSE D Pf?°�� Gregory Sachs, PE FIELD ]INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) ------------------------------------- r— cn FOUNDATION (2ND) � O G � ROUGH FRAMING& PLUMBING r r INSULATION PER N. Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS m . � b O x y - x d r� b SOffo(,t�OGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT co Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o ao�� Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT ' For Office Use Only ' ' e) q � lq' I L� 1 11'x'; PERMIT NO. /J Building Inspector: -NOV 2 Q 0 9M Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant isnot the owner,an Owner's Authorization form(Page 2)shall be completed. Date: 11/15/2022 OWNER(S)OF PROPERTY: Name: Brian Wills & Jay_e Dee_ SCTM#1090- 038.00-01.00_028.000 Project Address. 680 P_rivate_Road_7_,_East_Marion,_NY 11.9-3-9 Phone#: _63-1)_463=8429 Email: fly41iv2000@yahoo.com Mailing Address: 680 Private Road 7, East Marion, NY 11939 CONTACT PERSON: Name: Ines Fernandez (EmPower CES, LLC.) Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@empower-solar.com DESIGN PROFESSIONAL INFORMATION: Name: Gregory_D. Sachs Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@empower-solar.com CONTRACTOR INFORMATION: Name: EmPower CES, LLC. Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@empower-solar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: IXOther Roof mounted solar panels $$28,962.06 Will the lot be re-graded? ❑Yes DXNo Will excess fill be removed from premises? ❑Yes NNO 1 PROPERTY INFORMATION Existing use of property: Res idential-LF_amily Intended use of property: Residential 1 Family Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑YesXNo IF YES, PROVIDE A COPY. ISI Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by .Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print nam Fernandez WAuthorized A ent ❑Owner Signature of Applicant: 49 yv Ryan osor NOTARY PUBLIC,STATE OF NEW YORK STATE OF NEW YORK) Registration No.01M06412506 SS: Quallfied In Nassau County COUNTY OF ) Commission Expires December 28,2024 Ines Fernandez being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 23_day of Alb.uyjm tf- X r ,20 4 Notary Putlic PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I� Brian Wills &Jaye Dee residing at 680 Private Road 7, East Marion, NY 11939 do hereby authorize Ines Fernandez to apply on my b halfTown of Sout old Building Department for approval as described erein. 1p c}— ;/�� . Owner's Signature Date Print Owner's Name 2 VBUILDING DEPARTMENT-Electrical Inspector ON . Off' �GK4 TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631),765-1802 - FAX (631) 765-9502 .rogerrosoutholdtownnV.gov— sea nd(cD_southoldtown nv.qov_ APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: 1/11/2022 Company Name: , EmPower CES,_LLC. Name: Timothy Crotty License No.: ME-65990 email: Perm ifti ng(ED-em power-solar.com Address:--4589 Austin Blvd.,-Island-Park,-NY 11558 Phone No.: (516)-544-4592 JOB SITE INFORMATION (All information Required) Name: Brian Willis&,la)me Dee Address: _680:Private Road-T, East Marion,-NY-1-1939 Cross Street: it Phone No.: (63,1)463-8429 Bldg.Permit#: Lf email: fly4liv2000@yahoo.com i. Tax Map District:,- 1000 Section: a.Q0 Block. CLO—0 ----- - Lot: 028.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of roof mounted solar panels(21)§PR-415w ACPV modules, 8.72kW total system size Circle All That Apply: Is job ready for inspection?: YES NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size I.Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected -Underground - Overhead Underground Laterals 1 2 H Frame Pole Work done on Service? Y N "Additional Information;, PAYMENT-DUE-WITH APPLICATION Request for Inspection Form.xis it -----------. NYSIFPO sox 66699,Albany,NY 12206 New York State Insurance Fund I nyelf eom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE A A A A A A 522407627 0. � AMWINS BROKERAGE OF NEW YORK 200 ELWOOD DAVIS ROAD f SUITE 200 LIVERPOOL NY 13088 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER EMPOWER CES LLC TOWN OF SOUTHOLD 4589 AUSTIN BLVD 543A ROUTE Z5 ISLAND PARK NY 11558, SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2546 624-4 563452 05/01/2022 TO 05/0112625 04/12/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2546 624-4. COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS'COMPENSATION.LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPTAS INDICATED BELOW, IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY; -INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COWCERT/ CRT EVALASP..THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT' OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY AFFORDS,COVERAGE TO THE SOLEPROPRIETOR;.PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. DAVID SCHIEREN GREG SACHS EMPOWER CES LLC THIS CERTIFICATE IS ISSUED AS A MATTER. OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AMEND,EXTEND ORALTER THE COVERAGE AFFORDED BY THE POLICY. I NEW YORK STATE INSURANCE FUND DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 263370983 1111 0000000000 1 03333.885841111' FormWC.EBT*OPRW Vc.i=3(0&W2019)IWC Polley-2S166MI U-263 163 [ 011 ��+i1[;�zd]s�s�l[ast l �tr�Inl carol] EMPOCES-01 ABELLO ACORO" CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) 5/6/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0757776 CONTACT NAME: HUB International Insurance Services Inc. PHONE,Ext):(310)568-5900 FAX,No):(310)568-9098 600 Corporate Pointe Suite 600 ADDRESS: Culver City,CA 90230 INSURERS AFFORDING COVERAGE NAIC# INSURER A:Southwest Marine&General Insurance Company 12294 INSURED INSURER B:.)amen River Insurance Company 12203 EmPower CES LLC INSURER C: 4589 Austin Boulevard INSURER D: Island Park,NY 11558 INSURERE: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTRINSD WVD ID MM/DD A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE [X]OCCUR X PK202200006109 5/4/2022 5/4/2023 DAMAGE TO RENTU RENTED $ 500,000 PREMISESMED EXP(Any oneperson) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY[ JECT F—]LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident $ ANY AUTO BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY Per accident $ HIRED NOW PROPERTY AMAGE AUTOS ONLY AUTOS ONLY Per accident $ B UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 5,000,000 X EXCESS LIAB CLAIMS-MADE 001306870 5/4/2022 5/4/2023 AGGREGATE $ 5'000'000 DEC) I .RETENTION$ $ WORKERS COMPENSATION OTH- AND EMPLOYERS'LIABILITY Y/N SPTERATLITE ER OFFICERO/MEMBER EXCLUDED?ECUTIVE ❑ N/A E.L.EACH ACCIDENT $ (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule may be attached If more space Is required) The certificate holder is listed as additional insured per attached endorsement#61-0202 0218. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Town Route h ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD YORK Workers'lf- STATE Compensation CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured EMPOWER CES LLC DBA EMPOWER SOLAR 310-534-7994 4589 AUSTIN BOULEVARD ISLAND PARK,NY 11558 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 522407627 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"I a" Southold, NY 11971 DBL252634 3c.Policy effective period 05/10/2021 to 05/09/2023 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 5/9/2022 g 9 Y (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is.NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 46,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS)Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) III IIIP1°°°1°211°°1°1°(11�2°11°1)�IIIIIII Additional Instructions for Form 1313-120.1 By signing this form,the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1 a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law.The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage(Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier. This Certificate is issued as a matter of information only and confers no rights upon the certificate holder.This Certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand and twenty-one,the payment of family leave benefits, for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand eighteen, the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (12-21)Reverse 1�p �f �l J i a Suffolk County Dept.of Labor,Licensing&Consumer Affairs ! HOME IMPROVEMENT LICENSE ` Name tGREGORY SACHS i Business Name s certifies that the firer is duly licensed EMPOWER CES LLC DBA he County of suffolk i License Number:H-50211 `I Rosalie Drago Issued: 05/30/2012 Commissioner Expires: 5/1/2024 1' i i 1 Suffolk County Dept.of Labor,Licensing&Consumer Affairs I . MASTER ELECTRICAL LICENSE Name TIMOTHY M GROTTY Business Name This certifies that the Empower CES LLC DBA nearer is duly licensed �y the County of suffolk License Number:ME-65990 Rosalie Drago Issued: 11/12/2021 Commissioner Expires: 1 1101/2023 I C i t 1 Gregory Sachs, PE 4589 Austin Blvd, (516)-544-4115 Island Park, NY 11558 permitting@empower-solar.com November 17,2022 To Whom It May Concern: The purpose of this letter is to certify that the existing roof structure located at: 680 Private Road 7,East Marion,NY 11939 can support the additional load of the solar energy system, in addition to wind,snow and gravity. Portions of roof structure covered and not covered with photovoltaic panels are in compliance with R324.4.1.1. Furthermore, it has been determined that the structure complies with the 2020 Residential Code of New York State including the ASCE 7. Please see Table 1 below for specific data relating to the calculations for each roof structure involved in the solar energy system installation. Table 1 Rafter Snow Wind Max Span Layers of Roof Surface ft spacing Cross Section Load Speed Kneewall Collar Ties ( ) (in) (psf) (mph) Shingles South-East 1 11.00 16 Nominal 2x6 20 135 No No 1 Sincerely, Gregory Sachs, PE �-qd _ X1 OF NE,tV Y 0RY co 0 ti: * Q� . S r C7 W - '1 08453 ARO ss1oNP�, _Road APPROVED AS ',<�TED DATE I-13 �3 B.P. # q8_7�)Lf F420---0-0 BY&b_. _ Y BUILDING DEPAR:MIF-N 1 2 3 4 s 6 7 8 9 10 11 12 13 765-1302 8 AM TO 4 PM FOPri;L LL WING INSPECTIONS: EM_.GW-- FC UNDATION-TWO REQUIRED S.O.L A R FC R POURED CONCRETE 4589 AUSTIN BLVD ISLAND PARK,NY 115 RC JGH-FRAMING,PLUMBING, o TEL:516-837-3459 ST RAPPING,ELECTRICAL&CAULKING RESIDENTIAL FAX:516-706-17t? IN ULATION www.empower-solae 4CP1 AL-CONSTRUCTION&ELECTRICAL H SOLAR PROJECT H PROPERWOFEMHCFG/JERCES.LLC.C.UNA�UTQHOI1R T BE COMPLETE FOR C.O. MATERIAL IS SCTIOTRICTLY PROHISITE@'YIL7yT INSTRUCTION SHALL MEET THE PROJECT TEAM. PRIOR SPECIFIC WRITTEN PE s REMENTS OF THE CODES OF NEW PROFESSIONAL SEAL YORK TATE. NOT RESPONSIBLE FOR OWNER: Brian&Jaye Dee Wills DESfG OR CONSTRUCTION ERRORS. G G PSC�O�S p S�0C) Addki(mal ,Q� PHONE: (631)463-8429 4 t RECORD:ENGINEER OF �" Ce__� �.,cati0n F SOLAR INSTALLER: GREGORY SACHS,PE =� - May r EMPOWER SOLAR t May Be Required. 4589 AUSTIN BLVD 4589 AUSTIN BLVD ISLAND PARK,NY 11558 Y 1 ISLAND PARK,NY 11558 PHONE:516-837-3459 �ARp�SS1pNP� PHONE:516-837-3459 E ELECTRICAL INSPECTION REQUIRED D i p REV: DESCRIPTION: DATE: A dL5cOhrQG+ m1 e PROJECT LOCATION DATA: SHEET INDEX: PROJECT NAME: �A •'�:680.Pnvate Rdr#,7; IoCo'*d Oubac s / Brian&Jaye Dee Wills r East IVlanoii;:NY 11939 ADDRESS:68U Private Road 7,East ST-01 COVER SHEET y S-01 EQUIPMENT LOCATIONS of, and � ty � Marion,NY 11939 PROJECT LOCATION: ofQ i S-02 STRUCTURAL 680 Private Road 7,East c SE-01 ELECTRICAL c �' 3 Marion,NY 11939 SCTM:1000-038.00-01.00-028.000 PROJECT#. PROJ.PHASE PERMIT DATE: - j yB DESIGNED BY: ED `y CHECKED BY: GS SCALE: ` ��/�NTS MAP TILE: OMPLY �YIT ALL CODES OF ;.{ NEiN-fdAk STA E &TOWN CODES A A 'STREQUIRE D CONDITIONS OF SO OLD TOWN ZU 1 2 3 4 5 6 7 8 9 10 11 12 13 ?-.rf.y�,„�=,},.v: SOUTHOLD TOWN PLMNWNS BOARi# y:: SOUTHOLO TMN TRUSTS NYS.DEC 1 2 3 4 5 6 7 8 9 10 11 12 13 41 EMPOWER SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 o TEL:516-837-3459 FAX:516-706-1789 PRIVATE ROAD 7 www.empower-sol ar.com H DRIVEWAY H TPNREOP ODUC IO DISCLOSED DISTRIBUTION F TIZED HIS EQUIPMENT LEGEND. REPRODUCTION OR DISTRIBUTION OFTNIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL MODULES G � UTILITY METER 2 G g❑ INVERTERS QOXY S'q��-� F 4] SOLAR DISCONNECT 0 MAIN SERVICE PANEL — �O 084531 E E AROFESSIONP 5 4 D D REV: DESCRIPTION: DATE PROJECT NAME: SETBACK LEGEND WILLS RESIDENCE ® 36"CLEAR PATH PROJECT LOCATION: C C 680 PRIVATE ROAD 7 ® 18"RIDGE SETBACK EAST MARION,NY 11939 PROJECTik. ® ACCESS ROOF rH-EAST ROOF 1: PROD.PHASE: PERMIT 21 SUNPOWER 415W-ACPV PANELS DATE: 11/1712022 B TOTAL POWER:8.715 kW B DESIGNED B ED ORIENTATION:140°;PITCH:30° CHECKED BY: GS TYPE 1:FLASHLOC DUO SCALE: NTS SOLAR ACCESS:78% TITLE: TSRF:74% EQUIPMENT LOCATIONS ROOF LAYOUT A NOT TO SCALE A SHEET: S-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER. 1 S O.L A R 4589 AUSTIN BLVD SUNPOWER MODULES ISLAND PARK,NY 11558 ON INVISIMOUNT RACKING TEL:516-837-3459 SHINGLES FAX:516-706-1789 www.empower-solar.com H THTHE INFORMATION DISCLOSED HEREIN IS THE SOLE RAFTERS H PROPERTY OFEMPOAERCES,LLC,UNAUOflQED REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL G G 'Y �'<P GORY �• S�O Fcn TYPICAL ROOF SECTION ' - NOT TO SCALE SUNPOWER PANEL SPECS O C��n"D4 5 3 E MODULE POWER(WdC) QTY MODEL# LENGTH WIDTH DEPTH WEIGHT TABLE S-1.1:MAX.ATTACHMENT SPACING E �SS10tA SPR-415 121 SPR-A-SERIES-AC 72.2" 40.0" 1.57" 46.5 LB PORTRAIT: 5'-4'7--F— LANDSCAPE: 8'-0" SPR-E/X-SERIES-AC 61.4" 41.2" 1.81" 42.9 LB D D REV: DESCRIPTION: DATE: NOTES: PROJECT NAME: 1. TOTAL SYSTEM DC POWER:8.72 kW Brian&Jaye Dee Wills 2.RACKING SYSTEM INSTALLED IN ACCORDANCE WITH CODE-COMPLIANT INSTALLATION MANUAL 3.ATTACHMENTS TO BE SECURED TO ROOF ASSEMBLY USING 5 mm STAINLESS STEEL SCREWS PROJECT LOCATION: C AND/OR 5/16"STAINLESS STEEL LAG BOLTS SPACED ACCORDING TO TABLE S-1.1 C 680 Private Road 7,East 4. ALL ATTACHMENTS TO ROOF, MOUNTING BRACKETS & HARDWARE MEET OR EXCEED NYS Marion,NY 11939 CODE REQUIREMENTS 5.INSTALLATION TYPICALLY MAINTAINS 7/8 INCH SPACING BETWEEN MODULES 6.SIZES OF STRUCTURAL MEMBERS THAT WERE NOT ACCESSIBLE FOR DIRECT MEASUREMENT PRDJEcr1r ARE BASED ON OBSERVATIONS OF ACCESSIBLE MEMBERS, CONSTRUCTION DEPTH OR PROJ.PHASE: PERMIT BOTH IN ADDITION TO KNOWLEDGE OF STANDARD CONSTRUCTION PRACTICES AT THE DATE: B TIME OF CONSTRUCTION B DESIGNED BY: ED 7. THIS DOCUMENT CERTIFIES THAT THE ROOF STRUCTURE HAS BEEN CHECKED FOR WIND, CHECKED BY: GS SNOW, UNBALANCED SNOW, LIVE AND DEAD LOADS BASED ON ASCE 7-10 CHAPTER 30- SCALE: NTS WIND LOADS - COMPONENTS AND CLADDING (C&C)AND FOR CONFORMANCE WITH THE TITLE: 2020 RESIDENTIAL CODE OF NEW YORK STATE.THIS CERTIFICATION DOES NOT APPLY TO STRUCTURAL ANY ADDITIONAL ROOF ALTERATIONS AFTER THE DESCRIBED INSTALLATION A 8.THIS ROOF STRUCTURE AS SHOWN IS ADEQUATE TO SUPPORT THE PROPOSED LOADS A SHEET: 9.REFER TO STRUCTURAL LETTER FOR SITE SPECIFIC AND ROOF SURFACE DATA S-02 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER_ NOTES: S0 L w R 4589 AUSTIN BLVD ISLAND PARK,NY 11558 0 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR TEL:516-837-3459 ELECTRIC SYSTEM) FAX:516-706-1789 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN www.empower-solar.com STANDARD INVERTER ASSEMBLY: SERVICE PANEL USING'SPLIT-BOLT CONNECTOR' H 3.IN SOME CASES POWER FOR DATA MONITORING ENCLOSURE MAYBE THEINFORMATIONFEMPOWELCSS.LLC.ENISTHE SOLE H PROPERTY ATION DISCLOSED HEREIN ISTHORQED DERIVED FROM MAIN SERVICE PANEL REPRODUCTION OR OIOF THIS PROHIBITED MATERIAL IS STRICTLY PROHIBITEDED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION 4.CONNECT UTILITY SIDE TO PANEL LUGS PROFESSIONAL SEAL 5.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 6.SIZE GEC AND EGC AS PER NEC 250.66,NEC 250.122 RESPECTIVELY 7.PROTECT GEC AND EGC SUBJECT TO PHYSICAL DAMAGE AS PER NEC G SOAR 250.64(B),NEC 250.120(C) G 1 8.FINAL SCHEMATIC SPECIFIC TO THIS INSTALLATION AVAILABLE UPON �O ARRAY /� REQUEST Q� FtY D INVERTER(S) AC DISCONNECT FLl 2 84531 _SS1 E E STANDARD EXTERIOR INTERCONNECTION: STANDARD INTERIOR INTERCONNECTION: D D REV: DESCRIPTION: DATE: PROJECT NAME: INTERIOR EXTERIOR INTERIOR EXTERIOR Brian&Jaye Dee Wills PROJECT LOCATION: 680 Private Road 7,East C TAP I K MAIN c Marion,NY 11939 S ER ENCLOSURE O 1 PANEMAIN LETTE SERVICE O PANEL PANEL PROJECT7k. UTILITY UTILITY PROJ.PHASE PERMIT METER METER DATE: B B DESIGNED BY: ED 1 CHECKED BY: GS SCALE: NTS TITLE: ELECTRICAL A A SHEET: SE-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 ENCLOSURE UTILITY NEMA 3R METER EM'P OWER I SOLAR > 4589 BRANCH C BRANCH B BRANCH A O ISLAND AND AUSTIN BLVD 1558 (7)SPR-415W MODULES (7)SPR-415W MODULES (7)SPR-415W MODULES TO MAIN TO PARK,NY o TEL:516-837-345345 9 TOTAL DC STC POWER:2.905 kW TOTAL DC STC POWER:2.905 kW TOTAL DC STC POWER:2.905 kW SERVICE UTILITY (7)ENPHASE IQ7HS MICRO INV (7)ENPHASE IQ7HS MICRO INV (7)ENPHASE IQ7HS MICRO INV FAX:516-706-1789 TOTAL AC POWER:2.688 kW TOTAL AC POWER:2.688 kW TOTAL AC POWER:2.688 kW PANEL GRID www.em power-solar.com AC4 CONTINUEAS CONTINUEAS CONTINUE AS THE INFORMATION DISCLOSED HEREIN ISTHE SOLE H REQUIRED FOR INV.... REQUIRED FOR INV.... REQUIRED FOR INV.... SUNPOWER H PROPERTY OF EMPOWER CES,U.C.UNAUTHORIZED ITHOUT SPECIFIED STRINGING SPECIFIED STRINGING SPECIFIED STRINGING DATA REPRODUCTION OR DISTRIBUTION OF THIS AC DISCONNECT MATERIAL SPECIFIC WSSION MONITORING PRIOR SPECIFIC WRITTEN PERMISSION AC1 ACI ACI 60A,2P CB PROFESSIONAL SEAL Lt L2 N (1)SPR-415W MODULE (1)SPR-415W MODULE (1)SPR-415W MODULE n G 20A,2P CB (1)ENPHASE MICRO INV. INV.2 (I)ENPHASE MICRO INV. INV- (1)ENPHASE MICRO INV. INV.2 G n G 20A,2P CB ACI ACI AC1 AC3 O 1 SPR-415W MODULE ^ 20A,2P CB �� ORY D. S,4 () (1)SPR416W MODULE (1)SPR-415W MODULE , (1)ENPHASE MICRO INV. INV.1 (1)ENPHASE MICRO INV. INV.1 (1)ENPHASE MICRO INV. INV.1 .,.f LiLi ^ 20A,2P CB rr�^ All" y FV LLI AC1 AC1 AC1 LLJ 84531 E Ross). E AC2 TO RACKING G AC COMBINING MLO PANEL GROUNDNEMA 3R 1 -PHASE 120/240V ° ENCLOSURE D REV: DESCRIPTION: DATE: (1)#6 AWG,EGC PROJECTNAME: WILLS RESIDENCE LABEL DESCRIPTION LABEL DESCRIPTION PROJECT LOCATION: ACI SPR AC CABLE AC2 1-1/2"PVC C (2)#12 AWG (6)#10 AWG C 680 Private Road 7 (1)#10 AWG,EGC East Marion,NY 11939 AC3 3/4"PVC AC4 2"PVC (3)#10 AWG (3)#2/0 AWG PROJECT# (1)#10 AWG,EGC (1)#4 AWG,GEC PROJ.PHASE: PERMIT DATE: 11/17/2022 B B DESIGNED BY: IV CHECKED BY: XX SCALE NTS TITLE: NOTES: THREE LINE ELECTRICAL SCHEMATIC 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR ELECTRIC SYSTEM) 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN SERVICE PANEL USING IRREVERSIBLE SPLICE TOTAL SYSTEM SIZE:8.72 kW A 3.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 21 SPR-415W MODULES 4.SIZE GEC AND EGC AS PER NEC 240.66,NEC240.122 RESPECTIVELY ( ) SHEET: 5.USE MC ONLY IF INCLUDED GEC IS ADEQUATELY SIZED. (21)ENPHASE IQ7HS MICRO-INV. SE-02 1 2 3 4 15 6 1 8 9 10 11 12 13 M SUNP ®WER° 425-410 W Residential Black AC Module SunPower°Maxeon Technology Built specifically for use with the SunPower Equinox°system,the only fully integrated solution designed,engineered,and warranted by one company. Highest Power Density Available y The patented,solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest-efficiency all-black AC solar module available? Part of the SunPower i Equinox'Solar System E E ' . •Seamless aesthetics c e e i Mlarger •Compatible with mySunPower monitoring Highest Lifetime Energy and Savings L fA Designed to deliver 60% more energy over 25 years in real-world conditions like partial shade and high temperatures.2 R z a L 4h A t_ _ a 0 V . _ M 140% Factory-integrated 13045 Microinverter _0 170410 u to } 145 p 60Go • Highest-power inte rated 100% More t g v 9015 Lifetime C AC module in solar w 80% Energy Conventional Panel >, 7045 • Engineered and calibrated N r,°>5 by SunPower for SunPower 0 5 10 15 20 25 Years of Operation AC modules Best Reliability, Best Warranty With more than 42.6 million and 15 GW of modules deployed around the world, SunPower technology is proven to last.That's why we stand behind our module and microinverter with the industry's best 25-year Combined Power and Product Warranty, r�___�✓ - -- ---- including the highest Power Warranty in solar. M425-BLK I M415-BLK M410-BLK SunPower Residential Black AC Module AC Electrical Data Inverter Model:Type H(Enphase IQ7HS) @240 VAC @208 VAC Max.Continuous Output Power(VA) 384 369 Nom.(L-L)Voltage/Range3 M 240/211-264 208/183-229 Max.Continuous Output Current(A) 1.60 1.77 Max.Units per 20 A(L-L)Branch Circuit4 10 9 CEC Weighted Efficiency 97.0% 96.5% Nom.Frequency 60 Hz 60 Hz Extended Frequency Range 47-68 Hz 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A 4.82 A Overvoltage Class AC Port III III AC Port Backfeed Current 18 mA 18 mA Power Factor Setting 1.0 1.0 Power Factor(adjustable) 0.85(inductive)/0.85(capacitive) 0.85(inductive)/0.85(capacitive) DC Power Data Warranties,Certifications,and Compliance SPR-M425-BLK-H-AC SPR-M415-BLK-H-AC SPR-M410-BLK-H-AC •25-year limited power warranty e Warranties 25-year limited product warranty Nom.Power (Pnom)W 425 415 410 Power Tolerance +5/-0% +5/-0% +5/-0% UL 1741/IEEE-1547 UL 1741 AC Module Module Efficiency 22.0% 21.5% 21.2% UL 61730(Type 2 fire rated) Temp.Coef.(Power) -0.29%/°C -0.29%/°C -0.29%/°C UL 62109-1/IEC 62109-2 FCC Part 15 Class B Shade Tolerance Integrated module-level max.power point tracking ICES-0003 Class B CAN/CSA-C22.2 NO.107.1-01 CA Rule 21(UL 1741 SA)s Tested Operating Conditions Certifications (includes Volt/Var and Reactive Power Priority) Operating Temp. -40°F to+185°F(-40°C to+85°C) and UL Listed PV Rapid Shutdown EquipmentT Compliance Enables installation in accordance with: Max.Ambient Temp. 122°F(50°C) NEC 690.6(AC module) Max.Test Load' Wind:125 psf,6000 Pa,611 kg/m2 back NEC 690.12 Rapid Shutdown(inside and outside the Snow:187 psf,9000 Pa,917 kg/m2 front array) Wind:75 psf,3600 Pa,367 kg/m2 back NEC 690.15 AC Connectors,690.33(A)-(E)(1) Max.Design Load Snow:125 psf,5400 Pa,550 kg/m2 front When used with AC module Q Cables and accessories Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) (UL 6703 and UL 2238)7 •Rated for load break disconnect PID Test 1000 V:IEC 62804 Mechanical Data Solar Cells 66 Maxeon Gen 6 Front Glass High-transmission tempered glass with anti-reflective coating Packaging Configuration Environmental Rating Outdoor rated Modules per pallet 25 Frame Class 1 black anodized(highest AAMA rating) Packaging box dimensions 75.4 x 42.2 x 48.0 in.(1915 x 1072 x 1220 mm) Weight 48 lbs(21.8 kg) Pallet gross weight 1300 Ib(590 kg) Recommended Max. Pallets per container 32 Module Spacing 1.3 in.(33 mm) Net weight per container 18,880 kg 73.7 In 1 Based on datasheet review of websites of top 20 manufacturers per IHS,as of July 2021. I 11872 mm]�I FRAME PROFILE 2 Maxeon 435 W,22.5%efficient,compared to a Conventional Panel on same-sized arrays(300 W,19%efficient approx.1.6 m2),7.9%more energy per watt(based on PVSyst pan files for avg.US climate),0.5%/yr slower T9 E degradation rate Gordan,et.al."Robust PV Degradation Methodology and Application."PVSC 2018). Grounding Holes E 3 Based on search of datasheet values from websites of top 10 manufacturers per IHS,as of June 2021. v 4 Limits mayvary.Refer to local requirements to define the number of microinverters per branch in your area. E -(- 5 Factoryset to IEEE 1547a-2014 default settings.CA Rule 21 default settings profile set during commissioning. e ry 6 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25'Q.All DC voltage is fully contained within the module. a o 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12;and C22.1-2015 Rule 64-218 Rapid (A)Long Side:1.3 in(32 mm) Shutdown of PV Systems,for AC and DC conductors;when installed according to manufacturer's instructions. I Short Side:0.9 in(24 mm) 8 Please read the safety and installation instructions for more information regarding load ratings and 1 mounting configurations. See www.sunpower.com/company for more reference information. Please read the safety and installation instructions for details. For more details,see extended datasheet:www.sunpower.com/solar-resources. Specifications included in this datasheet are subject to change without notice. ', 02022 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo and EQUINOX are o/l w registered trademarks of SunPower Corporation in the U.S.MAXEON is a registered trademark of Maxeon Solar L�8TED E478= 544400 ReVA Technologies,Ltd.For more information visit www.maxeon.com/legal. nba.l°r„e P°R°­­Typ.2 January 2022 1-800-SUNPOWER sunpower.com r . '4..R.. •.�" Y_.�/,%.� K.-. .Af'� ±it. ,"_S•'r S:F:, _' $ - _di' _ b 'P -- ,_!,°,�.�.tryc r_� _ ` - .r• it �& r ov- AA - •r Simple and Fast Installation Integrated module-to-rail grounding i Pre-assembled mid and end clamps Levitating mid clamp for easy placement —¢R = Mid clamp width facilitates consistent,even module spacing - UL 2703 Listed integrated grounding Flexible Design — Addresses sloped and low-sloped residential r? roofs Design in landscape and portrait with up to 8' rail span Pre-drilled rails and rail splice Rails enable easy obstacle management Elegant Simplicity Customer-Preferred Aesthetics SunPower° InvisiMountTM is aSunPower-designed Best-in-class system aesthetics Black anodized components rail-based mounting system. The InvisiMount system Low-profile mid clamps and capped,flush addresses residential sloped roofs and combines faster end clamps installation time, design flexibility, and superior aesthetics. i Part of Superior System Classic InvisiMount is specifically envisioned and engineered Best-in-class system reliability and aesthetics to pair with SunPower modules; Universal InvisiMount is Optional rooftop transition flashing,rail- mounted)-box,and wire management rail clips compatible with a wide range of modules. The resulting Combine with SunPower modules and system-level approach amplifies the installation and mySunPower`D monitoring app aesthetic benefits—for homeowners and for installers. sunpower.com �_- - m • • •" r ._.r, - Si'%*iC�=_---ted_=-_. _._ _♦ ..F SunPowe'rO InvisiMountTIMResidential . System • InviSiMount • • A_ woo Ground Lug Assembly Rail and Rail Splice Mid Clamp Ground Lug Assembly Rail and Rail Splice Universal Mid Clamp Row-to-Row Spacer Row-to-Row Grounding Clip End Clamp Row-to-row Grounding Jumper Universal End Clamp (DynoBond) InvisilMount Component Details InvisilMount Operating Conditions Classic mid clamp Black oxide stainless steel 300 series 63 g(2.2 oz) Temperature —40°C to 90°C(-40°F to 194°F) Universal mid clamp Black anodized aluminum 6000 series 60 g(2.1 oz) Classic end clamp Black anodized aluminum 6000 series 110 g(3.88 oz) RoofAttachrnept'Hardware Warranties Universal end clamp Black anodized aluminum 6000 series 103 g(3.63 oz) Refer to roof attachment hardware manufacturer's Rail Black anodized aluminum 6000 series 830 g/m(9 oz/ft) documentation. Rail splice Aluminum alloy 6000 series 830 g/m(9 oz/ft) Rail bolt M10-1.5 x 25 mm;custom T-head SS304 18 g(0.63 oz) InvisiMounte pone • Rail nut M10-1.5;DIN 6923 SS304 nominal Classic Uplift 664 Ibf Ground lug assembly SS304;A2-70 bolt;tin-plated copper lug 106.5 g(3.75 oz) Mid clamp Shear 540 Ibf Row-to-row grounding clip SS 301 with SS 304 M6 bolts 75 g(2.6 oz) Uplift 9621b Universal P Row-to-row grounding jumper Stainless steel 300 series 10 g(0.35 oz) Mid clamp Shear 4371b Row-to-row spacer Black POM-grade plastic Classic Uplift 899 Ibf Roof ® End clamp Shear 220 IbF InvisiMount Comp Shingle Attachment with Pegasus Universal Uplift 6051b InvisiMount Flat Tile Replacement Attachment with Pegasus End clamp Shear 242 Ib InvisiMount S-Tile Replacement Attachment with Pegasus InvisiMount W-Tile Replacement Attachment with Pegasus Moment:upward 548 lbf-ft Rail Moment:downward 580 Ibf-ft InvisiMount • Certifications Moment:upward 548lbf-ft 25-year product warranty Rail splice Warranties 5-year finish warranty Moment:downward 580 Ibf-ft Uplift 10001bf Certifications UL 2703 Listed L-foot Class A Fire Rated Shear 390 Ibf With Classic InvisiMount,a module frame that is compatible with the InvisiMount system is required for hardware interoperability;modules without this frame may be used with Universal InvisiMount. :SunPower recommends that all Equinox',InvisiMount',and AC module systems always be designed using the InvisiMount Span Tables#524734.If a designer decides to instead use the component capacities listed in this document to design a system,note that the capacities shown are Load and Resistance Factor Design(LRFD)design loads,and are NOT to be used for Allowable Stress Design(ASD)calculations;and that a licensed Professional Engineer(PE)must then stamp all calculations.Ifyou have any questions please contact SunPower Technical Support at 1-855-977-7867. sunpower.com Uc 2022 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo,EQUINOX,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. 509506 RevG All other trademarks are the property of their respective owners.Specifications included in this datasheet are subject to change without notice. D. M SUNP ®WER° 425-410 W Residential Black AC Module SunPower°Maxeon°Technology Built specifically for use with the SunPower Equinox°system,the only fully integrated solution designed, engineered, and warranted by one company. Highest Power Density Available y The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest-efficiency all-black AC solar module available? Part of the SunPower Equinox Solar System v E � E � � I •Seamless aesthetics j m�- N larger r � •Compatible with mySunPower monitoring ` I Highest Lifetime Energy and Savings oI Designed to deliver 60/o more energy over 25 years in LiI7 real-world conditions like partial shade and high temperatures.2 _ o 15045 - - - — - -- - — - --- - — — - - - - — - 140% -- - - - -- - - Factory-integrated v 130% f 1204✓ LI to Microinverter } 110% sono • Highest-power inte rated 700' More $ 9045 Lifetime AC module in solarw 4045 Energy Conventional Panel T 70b • Engineered and calibrated i N 6044 by SunPower for SunPower 0 5 10 15 70 25 Years of Operation AC modules Best Reliability, Best Warranty With more than 42.6 million and 15 GW of modules deployed i around the world, SunPower technology is proven to last.That's why we stand behind our module and microinverter with the industry's best 25-year Combined Power and Product Warranty, --- - i including the highest Power Warranty in solar. r M425-BLK M415-BLK M410-BLK SunPower Residential Black AC Module AC Electrical Data Inverter Model:Type H(Enphase IQ7HS) @240 VAC @208 VAC Max.Continuous Output Power(VA) 384 369 Nom.(L-L)Voltage/Range3 M 240/211-264 208/183-229 Max.Continuous Output Current(A) 1.60 1.77 Max.Units per 20 A(L-L)Branch Circuit" 10 9 CEC Weighted Efficiency 97.0% 96.5% Nom.Frequency 60 Hz 60 Hz Extended Frequency Range 47-68 Hz 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A 4.82 A Overvoltage Class AC Port III III AC Port Backfeed Current 18 mA 18 mA Power Factor Setting 1.0 1.0 Power Factor(adjustable) 0.85(inductive)10.85(capacitive) 0.85(inductive)/0.85(capacitive) DC Power Data Warranties,Certifications,and Compliance SPR-M425-BLK-H-AC SPR-M415-BLK-H-AC SPR-M410-BLK-H-AC Warranties •25-year limited power warranty Nom.Power6(Pnom)W 425 415 410 25-year limited product warranty Power Tolerance +5/-0% +5/-0% +5/-0% UL 1741/IEEE-1547 UL 1741 AC Module Module Efficiency 22.0% 21.5% 21.2% UL 61730(Type 2 fire rated) Temp.Coef.(Power) -0.29%/°C -0.29%/°C -0.29%/°C UL 62109-1/IEC 62109-2 FCC Part 15 Class B Shade Tolerance Integrated module-level max.povier point tracking ICES-0003 Class B CAN/CSA-C22.2 NO.107.1-01 CA Rule 21(UL 1741 SA)s Tested Operating Conditions Certifications (includes Volt/Var and Reactive Power Priority) and UL Listed PV Rapid Shutdown Equipment? Operating Temp. -40°F to+185°F(-40°C to+85°C) Compliance Max.Ambient Temp. 122°F(50°C) Enables installation in accordance with: NEC 690.6(AC module) Max.Test Loads Wind:125 psf,6000 Pa,611 kg/M2 back NEC 690.12 Rapid Shutdown(inside and outside the Snow:187 psf,9000 Pa,917 kg/m'front array) Max.Design Load Wind:75 psf,3600 Pa,367 kg/m2 back NEC 690.15 AC Connectors,690.33(A)-(E)(1) Snow:125 psf,5400 Pa,550 kg/M2 front When used with AC module Q Cables and accessories Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) (UL 6703 and UL 2238)7 •Rated for load break disconnect Mechanical Data PID Test 1000 V:IEC 62804 Solar Cells 66 Maxeon Gen 6 Front Glass High-transmission tempered glass with anti-reflective coating Packaging Configuration Environmental Rating Outdoor rated Modules per pallet 25 Frame Class 1 black anodized(highest AAMA rating) Packaging box dimensions 75.4 x 42.2 x 48.0 in.(1915 x 1072 x 1220 mm) Weight 48 lbs(21.8 kg) Pallet gross weight 1300 Ib(590 kg) Recommended Max. 13 i33 Pallets per container 32 Module Spacing . n.( mm) Net weight per container 18,880 kg 73.7 in 1 Based on datasheet review of websites of top 20 manufacturers per IHS,as of July 2021. I [1872 mm] I FRAME PROFILE 2 Maxeon 435 W,22.5%efficient,compared to a Conventional Panel on same-sized arrays(300 W,19%efficient, approx.1.6 m'),7.9%more energy per watt(based on PVSyst pan files for avg.US climate),0.546/yr slower T9 degradation rate 0ordan,et.al."Robust PV Degradation Methodology and Application."PVSC 2018). Grounding Holes E 3 Based on search of datasheet values from websites of top 10 manufacturers per IHS,as of June 2021. 3 4 Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. E 5 Factory set to IEEE 1547a-2014 default settings.CA Rule 21 default settings profile set during commissioning. E InEl E 6 Standard Test Conditions(1000 W/mz irradiance,AM 1.5,25°Q.All DC voltage is fully contained within the module. p o 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12;and C22.1-2015 Rule 64-218 Rapid 7 (A)Long Side:1.3 in(32 mm) Shutdown of PV Systems,for AC and DC conduttors;when installed according to manufacturer's instructions. Short Side:0.9 in(24 mm) 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. See www.sunpower.com/company for more reference information. Please read the safety and installation instructions for details. For more details,see extended datasheet:www.sunpower.com/solar-resources. Specifications included in this datasheet are subject to change without notice. ', M 02022 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo and EQUINOX are u� „,•a o� 544400 RevA registered trademarks of SunPower Corporation in the U.S.MAXEON is a registered trademark of Maxeon Solar LISTED� Technologies,Ltd.For more information visit www.maxeon.com/legal. MMM,rr,°Nd-one:typo z January 2022 1-800-SUNPOWER : s •• • . . ® iija . MEL . . • Simple and Fast Installation t Integrated module-to-rail grounding Pre-assembled mid and end clamps • Levitating mid clamp for easy placement Mid clamp width facilitates consistent,even module spacing - UL 2703 Listed integrated grounding Flexible Design Addresses sloped and low-sloped residential roofs Design in landscape and portrait with up to 8' ` rail span Pre-drilled rails and rail splice Rails enable easy obstacle management Elegant Simplicity Customer-Preferred Aesthetics Best-in-class system aesthetics SunPower® InvisiMountTm is a SunPower-designed Black anodized components rail-based mounting system.The InvisiMount system Low-profile mid clamps and capped,flush addresses residential sloped roofs and combines faster end clamps installation time, design flexibility, and superior aesthetics. Part of Superior System Classic InvisiMount is specifically envisioned and engineered Best-in-sass system reliability and aesthetics to pair with SunPower modules; Universal InvisiMount is Optional rooftop transition flashing,rail- mounted J-box,and wire management rail clips compatible with a wide range of modules. The resulting Combine with SunPower modules and system-level approach amplifies the installation and mySunPower-'monitoring app aesthetic benefits—for homeowners and for installers. i 1 _ Vii. .. _ �(�lll ;;, sunpower.com _ i. i n - 7 Ll13 SunPowerO InvisiMountTIM Residential MountInvisi • •• Mid Clamp Ground Lu Rail and Rail Splice g Assembly Rall and Rail Splice Universal Mid Clamp Ground Lug Assembly P Row-to-Row Spacer Row-to-Row Grounding Clip End Clamp Row-to-row Grounding Jumper Universal End Clarnp (DynoBond) InVisiMount ComponentDetails- Classic e Classic mid clamp Black oxide stainless steel 300 series 63 g(2.2 oz) Temperature -40°C to 90°C(-40°F to 194°F) Universal mid clamp Black anodized aluminum 6000 series 60 g(2.1 oz) Classic end clamp Black anodized aluminum 6000 series 110 g(3.88 oz) Roof• • Universal end clamp Black anodized aluminum 6000 series 103 g(3.63 oz) Refer to roof attachment hardware manufacturer's Rail Black anodized aluminum 6000 series 830 g/m(9 oz/ft) documentation. Rail splice Aluminum alloy 6000 series 830 g/m(9 oz/ft) Rail bolt M10-1.5 x 25 mm;custom T-head SS304 18 g(0.63 oz) e • •• - ' ! .o Rail nut M10-1.5;DIN 6923 SS304 nominal Classic Uplift 6641bf Ground lug assembly SS304;A2-70 bolt;tin-plated copper lug 106.5 g(3.75 oz) Mid clamp Shear 540 Ibf Row-to-row grounding clip SS 301 with SS 304 M6 bolts 75 g(2.6 oz) Universal Uplift 9621b Row-to-row grounding jumper Stainless steel 300 series 10 g(0.35 oz) Mid clamp Shear 4371b Row-to-row spacer Black POM-grade plastic Classic Uplift 899 Ibf •• End clamp Shear 220 Ibf InvisiMount Comp Shingle Attachment with Pegasus Universal Uplift 6051b InvisiMount Flat Tile Replacement Attachment with Pegasus End clamp Shear 2421b InvisiMount S-Tile Replacement Attachment with Pegasus InvisiMount W-Tile Replacement Attachment with Pegasus Moment:upward 548 Ibf-ft Rail Moment:downward 580 Ibf-ft lnvl�iM• And • Moment:upward 548 Ibf-ft 25-year product warranty Rail splice Warranties Moment:downward 580 Ibf-ft 5-year finish warranty UL 2703 Listed Uplift 1000 Ibf Certifications Class A Fire Rated L-foot Shear 390 Ibf With Classic InvisiMount,a module frame that is compatible with the InvisiMount system is required for hardware interoperability;modules without this frame may be used with Universal InvisiMount. SunPower recommends that all Equinox',InvisiMount',and AC module systems always be designed using the InvisiMount Span Tables#524734.If a designer decides to instead use the component capacities listed in this document to design a system,note that the capacities shown are Load and Resistance Factor Design(LRFD)design loads,and are NOT to be used for Allowable Stress Design(ASD)calculations;and that a licensed Professional Engineer(PE)mustthen stamp all calculations.If you have anyquestions please contact SunPower Technical Support at 1-855-977-7867. sunpower.com 0 2022 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWERlogo,EQUINOX,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. 509506 RevG All other trademarks are the property of their respective owners.Specifications included in this datasheet are subject to change without notice. Datasheet