Loading...
HomeMy WebLinkAbout48000-Z �oyQs�EFO(,f�vG Town of Southold 8/2/2023 P.O.Box 1179 0 53095 Main Rd 01 `lapS�t Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44362 Date: 8/2/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 375 Tucker Ln., Southold SCTM#: 473889 Sec/Block/Lot: 59.41-7 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/23/2022 pursuant to which Building Permit No. 48000 dated 6/24/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Kessler,Emily of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48000 6/29/2023 /PLUMBERS CERTIFICATION DATED Au orizkj Signature TOWN OF SOUTHOLD o °aye BUILDING DEPARTMENT TOWN CLERK'S OFFICE 2. o W.P SOUTHOLD, NY 4,fpl `r BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48000 Date: 6/24/2022 Permission is hereby granted to: Kessler, Emily 405 Kerwin Blvd Greenport, NY 11944 To: Install roof mount solar to existing single family dwelling as applied for. At premises located at: 375 Tucker Ln., Southold SCTM #473889 Sec/Block/Lot# 59.-11-7 Pursuant to application dated 5/23/2022 and approved by the Building Inspector. To expire on 12/24/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector SO!/P,Ql 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlina-town.Southold.ny.us Southold,NY 11971-0959 QIycoUNTY,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Emily Kessler Address: 375 Tucker Ln city:Southold st: NY zip: 11971 Building Permit#: 48000 Section: 59 Block: 11 Lot: 7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 8.8kW Roof Mounted PV Solar Energy System w/ (22) QCELLgpeak duo blk400W Modules, AC Disconnect, IQ3 Combiner Notes: Solar Inspector Signature: P Date: June 29, 2023 S.Devlin-Cert Electrical Compliance Form OF SOUTyo v C)d J �r ---- # * TOWN OF SOUTHOLD B ILDIN DEPT. �o • �o `ycnurm��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) -[ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Ap DATE INSPECTOR so * TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 INSPECTION FOUNDATION 1ST ROUGH PL13G. FOUNDATION 2ND PSULATION/CAULKING FRAMING /STRAPPING FINAL so/,OLP--- FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL) CODE VIOLATION PRE C/O RENTAL_ REMARKS: OIL— La— L DATE INSPECTOR so * TOWN OF SOUTHOLD BUILDING DEPT. `ycourm,N�'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: s DATE INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS .►e FOUNDATION (1ST) ------------------------------------ C FOUNDATION (2ND) O y ROUGH FRAMING& PLUMBING -F r INSULATION PER N.Y. y STATE ENERGY CODE C' FINAL ADDITIONAL COMMENTSko in .b Elecksi ca ce-r+ �R o Z rn k � z x r� H x d m b y =o'o uFFocr°oGy TOWN OF SOUTHOLD —BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �y�o• �ao�� Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtowM.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: MAY 23 9097 Applications and forms must be filled out in their entirety. Incomplete BUILDING DEPT applications will not be accepted. Where the Applicant is not the owner,an TOWN OF SOUTHOLD Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPER : Name: GeSfLe BI. SCTM#1000- �� 7UU1lG'd�G Project Address: 67 3 7 /,-VC/�e7e/,f Phone#: �j TEmail: Mailing Address: 7f3 / S, SCom. CONTACT PERSON: Name:Danielle Rodger Mailing Address:7470 Sound Ave Mattituck NY 11952 Phone#:6317797993 Email:permits9e2sys.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:Element Energy LLC Mailing Address:7470 Sound Ave MattituCk NY 11944 Phone#:6317797993 Email:permits@e2sys.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration El Repair ❑Demolition Estimated Cost of Project: EOtherSolar $ Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? Dyes RNo 1 Zoho Sign Document ID:NPOZB3F(iBUgUYOWMW9HUHPTXQTXLlG6UPVK84C;UC;ISW PROPERTY INFORMATION r Existing use of property: AJI Z _ Intended use of property! Zone or use district in which premises is situated: 'Are there any covenants and restrictions with respect to this property? ❑Yes"]No IF YES, PROVIDE A COPY. 4 Ac ECheck Box After Reading: The owner/contractor/design professlonal is responsible for all drainage and storm water Issues as provided by apter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Z) uthorized Agent []Owner Signature of Applicant: Date: F 1oo9 STATE OF NEW YORK) S: COUNTY OF being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the . (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of._ 1QJ _- 20 j,;)— A A 1 0 jtn Notary Public DEBRA A SEPULVEDA PROPERTY OWNER AUTHORIZ T10NW=yPuBuqsrAmoFmwy= (Where the applicant is not the ow er) Re&budonNo601SWi2W Qu olklin Covnv / MyCommis�i0n Ezpitq n1' / residing at > do hereby authorize _ 01 _ to apply on my behalf to the Town of Southold Building Department for approval as described herein. May 19 2022 Owner's Signature Date Print Owner'4 Name 2 BUILDING DEPARTMENT- Electrical I101- ELECTRICIAN or TOWN OF SOUTHOLD MAY 2 x" Town Hall Annex - 54375 Main Road - PO ox 1179 - 3 2022 ca Southold, New York 11971-0959 TowNoFsouEP7.- Telephone 631 765-1802 - FAX 631 765-9502 TioLo 4L rggeg(t�southoldtownny.gov---_seand@§6utholdtownnygov APPLICATION.FORELECTRICAL .INSPECTION INFORMATION (All information Required) Date: Company Name: �¢ v. ' Electrician's Name: .� j CGL License No.: Elec. email:. Elec. Phone No: 77 I request an email copy of Certificate of Compliance Elec. Address.: .JOB SITE INFORMATION (All Information Required) Name: Address: 3-7 Cross Street: Phone No.: o9, 3.. 7,,Ipf3 Bldg.Permit#: email:- - Tax.'Map.District: 1000 Section: j' 9 00 Block:. p Lot: `7- BRIEF -BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly); Square Footage: Circle All-ThatApply: Is job ready for inspection?: ❑ YES NO in Rough In ❑ Final Do you need a Temp Certificate?! ❑ YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph F- 13 Ph Size: A #Meters, Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead #'Underground Laterals. 1 _ 2 H Frame Pole Work done on Service? F1Y FIN Additional Information: PAYMENT DUE WITH APPLICATION BUILDING DEPARTMENT Electrical I;1O or Lr TOWN OF SOUTHOLD MAY 2- 3 102ITown Hall Annex - 54375 Main Road - ox BUILDING1179 Southold, New York 11971-0959 �owrd ooPr. � Telephone(631) 765-1802 - FAX (631) 765-9502 �c '` rogerr 0southoldtownny nov - seandCc-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: ,�� Electrician's Name: /{ IVI License No.: S' Elec. email: { Elec. Phone No: / 77 1 4 M I request an email copy of Certificate of Compliance Elec. Address.: U fr.�i � f - JOB SITE INFORMATION (All Information Required) Name: �a�iss/rpt Address: 37S• T61�? Cross Street: Phone No.: Y3 Bldg.Permit#: L q5 00 email Tax Map District: 1000 Section: S 7 Block: j p Lot: d d Cl BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): ���/cu/ C��- �Cil/ �-O�l�• ��° Square Footage: 7-1 Circle All That Apply: Is job ready for inspection?: YES NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES PNO Issued On Temp Information: (All information required) Service SizeF11 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[:]Flood Reconnect[:]Service Reconnect[]Underground❑Overhead #Underground Laterals 1 2 M H Frame D Pole.Work done on Service? Y MN Additional Information: PAYMENT DUE WITH APPLICATION � � 7ac� 2 � NYSIF New York State Insurance Fund 8 CORPORATE CENTER DR,3RD FLR,MELVILLE,NEW YORK 11747-3129 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) ' � D T J ^^"^^ 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 706281 07/13/2021 TO 07/13/2022 7/15/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:438572026 DATE(MM/DD/YYYY) A`oRL> CERTIFICATE OF LIABILITY INSURANCE 7/15/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: ROBERTS.FEDE INSURANCE AGENCY PHONE - - FAX - 23 GREEN STREET,SUITE 102 E-/MAILo Extl: AIC No HUNTINGTON,NY 11743 ADDRESS: ROBERT S.FEDE INSURANCE INSURERS AFFORDING COVERAGE NAIC# INSURER A: INSURED INSURER B:STATE INSURANCE FUND 523930 Element Energy LLC INSURERC:SHELTER POINT POINT ELEMENT ENERGY SYSTEMS INSURERD: 7470 SOUND AVENUE INSURER E: MATTITUCK, NY 11952 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR POLICY POLICY EXP LTR TYPE OF INSURANCE IVSD WVD SUER POLICY NUMBER MM DD/YYY MM/DDLIMITS COMMERCIAL GENERAL LIABILITY CL00275204 7/14/2021 7/14/2022 EACH OCCURRENCE $ 3,000,000 X X DAMAGE TO RENTED CLAIMS-MADE F`1_1 OCCUR PREMISES Ea occurrence) ccurrence $ 100,000 A MED EXP(Any one person) $ 5000 IMA389203 7/14/2021 7/14/2022 PERSONAL 8 ADV INJURY $ 3000000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 3,000,000 PPOLICY 1 PRO JECT F—] LOC PRODUCTS-COMP/OP AGG $ 3000000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ _ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident r $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY Y/N 124494445 7/13/2021 7/13/2022 STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 B OFFICER/MEMBER EXCLUDED9 7 N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1-000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1 non non NY State DBL DBL567527 1/01/2021 1/01/2022 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Rd THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 54375 Main R Southold NY1 d ACCORDANCE WITH THE POLICY PROVISIONS. AUTHO'RII_ZE,D-REPRESENTATIVE Raber1.S. Fede, ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD N� Efyo ORIK workers' CERTIFICATE OF INSURANCE COVERAGE S ATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c. Federal Employer Identification Number of Insured Work Location of Insured (Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e., Wrap-Up Policy) 823336604 2. Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Main Rd 3b.Policy Number of Entity Listed in Box 1 a" Southold, NY 11971 DBL567527 3c.Policy effective period 01/01/2021 to 12/31/2022 4. Policy provides the following benefits: 0 A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: ❑X A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/15/2021 By Midi, hf (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 4C or 513 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 11111111111°°1°°°°1°°1°°°111°11°°°�IIIIIII IRONRIDGE Flush Mount System r Built for solar's toughest roofs® IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified • All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. XR Rails O XR10 Rail XR100 Rail XR1000 Rail Bonded Splices 1 17 A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish • Clear anodized finish • Forms secure bonding Clamps & Grounding O UFOs Stopper Sleeves Grounding Lugs Microinverter Kits Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount MIs or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled &lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • Sized to match modules • Single tool installation • Kit comes assembled • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 Attachments O FlashFoot2 Conduit Mount Slotted L-Feet Bonding Hardware RN 07 -�k77M_ A�l ..4�� Alp__ A 4 - Flash and mount XR Rails Flash and mount conduit, Drop-in design for rapid rail Bond and attach XR Rails with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. • Twist-on Cap eases install • Twist-on Cap eases install • Secure rail connections - T&Square Bolt options • Wind-driven rain tested • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • Mill and black finish • Secures 3/a°or 1"conduit • Clear and black finish • Assembled and lubricated Resources _ Design Assistant P NABCEP Certified Training _ ��Roy --- Go from rough layout to fully �° Earn free continuing education credits, — engineered system. For free. NA— while learning more about our systems. _ — Go to IronRidge.com/design Go to IronRidge.corn/training Data Sheet Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7 MicroTM and Enphase IQ 7+ MicroTM IQ 7 and 17+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ EnvoyTM, Enphase IQ Battery'M, and the Enphase Enlighten TM monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple Faster installation with improved,lighter two-wire cabling ti f, Built-in rapid shutdown compliant(NEC 2014&2017) i Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed m • Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements - Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U� *The IQ 7+Micro is required to support 72-cell modules. n ENPHASE. To learn more about Enphase offerings,visit enphase.com Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235W-350W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60 V Peak power tracking voltage 27V-37V 27 V-45 V Operating range 16V-48V 16 V-60 V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15A 15A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240V/ 208V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connectortype(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.Seethe compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com EN PHASE. ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 powered by DUO ® ! i TOP BRAND PV ! �q EUROPE Warranty ,220 2/ O CELLS Pmdact&Pafmnmce Yield Security BREAKING THE 20%EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY (?; Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology,Hot-Spot Protect and Traceable Quality Tra.Q'M. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year l—„ linear performance warranty2. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96 h) a See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION Format 74.0 in x 41.1in x 1.261n(including frame) (1879mm x 1045mm x 32mm) 14'0•(127nimm) Ise 3as.smm) 42.e•(10aamm) I Weight 48.5 lbs(22.0 kg) Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with =a9r(12soaun) anti-reflection technology Ems 4x0-a49wmna019(4 mm) Back Cover Composite film 3sz(9aemm) Frame Black anodized aluminum ® 411•(1046mm) Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes Le°�� =49s•(nso ) Cable 4mm2 Solar cable;(+)2_49.2in(1250mm),(-)2_49.2in(1250mm) -.=7~ exDe ego naea 4x Ma .g doa(DETAIL A) _ Connector Steubli MC4;IP68 17s(22mm) DETMLA 0.83'(Samm) F-i CAV(24.5mm)I�I0.33.19.amm) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC1(POWER TOLERANCE+5W/-0W) Power at MPP' PMPP [W] 385 390 395 400 405 E Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14' 11.17 E Open Circuit Voltage' Vcc [V] 45.19 45.23 45.27 45.30 45.34 .E Current at MPP IMPP [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VMPP [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' q [%] 2_19.6 2_19.9 2_20.1 120.4 2_-20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PMPP [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Vcc [V] 42.62 42.65 42.69 42.72 42.76 c 2 Current at MPP IMPP [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMPP [V] 34.59 34.81 35.03 35.25 35.46 Weasurement tolerances PMPP±3%;Isc;Vcc±5%at STC:1000 W/m2.25±2°C,AM 1.5 according to IEC 60904-3.2800 W/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE m 0- -ocrius o ^Lt u0 --7-----f-----i----- ---- u- _ At least 98 h of nominal power during y I D I i Z 3 m.o �� first year.Thereafter max.0.5% Z ao 94------ ------------------------------ degradation per year.At least 93.5% w' of nominal power up to 10 years.At 4 z least 86%of nominalP ower u to w P �Z ------------- 25 years. g --r-----r-----r----i----- z I � I � o o e. All data within measurement toleranc- o ® --------------------- - es.Full warranties in accordance with eo a 200 aoo "a .oD woo the warranty terms of the Q CELLS 0 g IRRADIANCE Inv/m'I ti u m sales organisation of your respective o o w m 2a 24 country. 9mvw a,.ea9�o-mmia,ireiow�mme. YEARS Typical module performance under low irradiance conditions in o comparison to STC conditions(25°C•1000W/m2) m TEMPERATURE COEFFICIENTS o Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Vcc P [%/K] -0.27 Temperature Coefficient of PMP, y [%/K] -0.34 Nominal Module Operating Temperature NMOT. [°F] 109±5.4(43±3°C) m 0 PROPERTIES FOR SYSTEM DESIGN w Maximum System Voltage Vacs [V] 1000(IEC)/1000(UL) PV module classification Class II a Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 Max.Design Load,Push/Pull' [lbs/ft2] 75(3600Pa)/55(2660Pa) Permitted Module Temperature -40'Fupto+185°F e Max.Test Load,Push/Pull' [IbS/ft2] 113(5400 Pa)/84(4000 Pe) on Continuous Duty (-40'Cupto+851C) m o, 'See Installation Manuel QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION Lv^�Jy m P O o UL 61730,CE-com Iiant, a3•� �'� Quality Controlled C61730Rheinlend, (Poor, 1o-o IEC61215:2016,IEC61730:2016,U.S.Patent No.9,893,215(solar cells), Tovabmw Horizontal 76.4in 43.3 in 48.0in 1656lbs 24 24 32 2QCPV Certification ongoing. Cpackaging 1940mm 1100mm 1220mm 751kg pallets pallets modules omma = UL B1T30 loiln2]a2n n Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Henwhe O CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1949 748 59 961 EMAIL inquiryQus.q-cells.com I WEB www.q-cells.us Zoho Sign Document ID:FOHNN7GHZFMYNGMBCWMKLSRWBYEDIMTVWQV4_DMRALE - Town of Southold May 16th, 2022 Building Department Town Hall Annex C Illi 2 54375 Main Road IV/ lS P.O. Box 1179 MAY 2 3 2092 Southold, New York 11971-0959 BUILDING DEPS TOWS!OF SOUTHOLD Subject: Roof Mounted Solar Panels at the Kessler Residence, 375 Tucker Ln. Southold, NY 11971 To Town of Southold: APPROVED 'C NOT 0 DATE: . -� B.P. 090 I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and s' 03-By': ;7 NOTIFY E��lLDING DEPARTMENT AT NFPA-70. These code requirements include the fact that the roof framing is adequate to support 765"1802 9 A.F0 TO 4 PNI FOR THE the additional loads from solar panels as well as roof ridge and peak access to first responders. iNISP ECTIO lS: REOUIRED I have evaluated the structural framing of the existing roof with the additional loading to account 2• f;.,, = •,,.5 :�, :9 �Y7:.� 1V� for the proposed solar panel application. Deflection and stresses of the structural components 3. iI-== ->.::J remain within the allowable for the existing roof for wind pressures from 140 mph, 3 second 4. ° ': 3 CO`•�`'��RUC T iON MUST EE:CCivi LE T v FOUR 0.0. gust, Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations h.i_:- , 01 N, ;r if C;10i SF1ALL It?IEET and methods are as indicated in the submitted plans. OF THE N.Y. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is _.,.:,,. ;ax :-,,.,;.;<< ;-.--y ;i lis Eta FOR my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also the wind analysis concluded that the mounting system as shown on the plans OCCUPANCY OR is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.9 pounds per square foot. USE IS UNLAWFUL Please contact me if you have any questions or comments about the above. WITHOUT CERTIFICATE NREQUIRED OF OCCUPANCY Sincerely, OF NEII,yCOMPLY WITH ALL.°CODES OF Gennaro Anthony Giustra. P.E. 0 A p� NEW YORK STATE&T6wN CODES Great Eastern Services, Inc. �� �P� c�G� AS REQUIRED.AN,D:CONDITIONS OF PO Box 240 * �_ 24 Harvey Rd 0 w Riverhead, NY 11901 2 �81tTHCLDTQWfPIPlANN1NG81 �o �034Q3 SOUi} LDTOWN;TRUSTEES Office: 631.543.9555A�OFESSIONt vY:S:OEC Mobile: 631.235.0189 Email: jerrygiustra@gmail.com RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. ?oho Sign Document ID:FOHNN7GHZFMYNGMBCWMKLSRW8YEDIMTVWQV4_DMRALE 5 C O P E Of WORK DE51GN t DRAFTING BY: ELEMENT ENERGY LLC TO INSTALL A 8.8 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE KESSLER RESIDENCE, GrtetlpOrt REVIEW BY J.M-NABGEP CERTIFIE LOCATED AT 375 TUCKERS LANE, SOUTHOLD, NY 1 1971. a� r West De O5 i 12-129 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID Horton Point Lighthouse Q THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. Nautical Museum ,.Shelter Isl: REVISIONS ® �• Heights DE5CRI1`r10N DATE REV is ;INAL 05- 6-2022 SYSTEM RATING kW DC STC ` Southold EQUIPMENT SUMMARY 22 QCELL Q.PEAK DUO BILK ML-G I O.A+ 400 WATT PV MODULES ��OF NEW Y Peconic M 22 ENPHASE IQ7PLUS-72-2-US MICRO INVERTERS RONRIDGE XR 100 MOUNTING SYSTEM �Q. O A G/ Q0 CONTRACTOR CO ���P��� 51-1 E ET INDEX * p � y ELEMENT ENERGY, L.L.C. PV-1 COVER PROJECT LOCATION 7470 SOUND AVE PV-2 SITE PLAN 2 -- Z MATTITUCK, NY 1 1952 PV-3 ROOF PV LAYOUT LICENSE # 43889-H PV-4 STRUCTURAL/DETAILS 4 SECTIONS �O X03443 �,� LICENSE# 52689-ME PV-5 3-LINE ELECTRICAL DIAGRAM A PV-6 LABELS R�FESSIONP� N GOVERNING CODES °° 2017 NATIONAL ELECTRICAL CODE. I 'r PROJECT NAME 2020 RESIDENTIAL CODE OF NEW YORK STATE. 27 °�U- 1 90° E +� r r ' A5CE 7-1 G AND NEPA-70. W 0l UNDERWRITERS LABORATORIES(UL)STANDARDS 240° 120° �• _ W 05HA 29 CFR 1910.269 2100 150° U W GENERAL NOTES 180° 1 . CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE W 0 z HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK AGREE THE SAME. AERIAL VIEW � 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED U � APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COM M ENT5 AND APPROVAL 5TAM P LL-j O INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES _ 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. LU � JURISDICTION. �L O I I 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB 51TE DURING THE THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND CONTINUE WITH THE WORK, HE SHALL A55UME ALL HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, 5HEET NAME 5. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY FABRICATED AND INSTALLED AS PER LATEST A.I.5.0 SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT SPECIFICATIONS. CONSTRUCTION. COVER IN BOARD OF FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND N ACCORDANCE WITH N.E.G. CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES REGULATIONS 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND COMMENCING WITH WORK. CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEERS DRAWING 5CALE 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON 8. THESE DRAWINGS AS INSTRUGMENTS OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. N •T•5 SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE EXTENSIONS TO THI5 PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF snT i EET IJU LP, 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS PV— RESULT OF HI5 WORK. — TAX MAP: 1000059001 100007000 ?oho Sign Document ID:F0HNN7GHZFMYNGMBCWMKLSRW8YED1 MTVWQV4_DMRALE LEGEND DESIGN&DRAFTING BY: EXISTING UTILITY METER ELEMENT ENERGY LLC MAIN LACE PANEL REVIEW BY J.M.NABCEP CERTIFIED NEW PV SUB-PANELS 051 1 12-129 A/C DISCONNECT COMBINER N INVERTERS GND ELECTRODE 0° REVISIONS PV MODULE DE5CRIPTION DATE REV j j X90°c ORGINAL OS-16-2022 RACKING RAIL ATTACHMENT POINT 1� RAFIERS /�/ j�/ Q ROOF PITCH ANGLE w jT 2400 SUNRUN METER a S VENT �> 4 2'-32" PLUMBING VENT �D /a SKY LIGHT /O CHIMNEY /N /N CONTRACTOR D y COMPOSITE SHINGLES GOOD CONDITION POTENTIAL SHADING ISSUES / 8°FIRE SETBACK @RDGE TRIMELEMENT ENERGY, LLC. /REMOVE AS NECESSARY 7470 SOUND AVE MATTITUCK, NY 1 1952 LICENSE # 43889-H LICENSE # 526(59-ME 12' 2a' / g / PROJECT NAME / 261- 1 4'I U z n z LUQ — �Q cn z im �m 20-6" C) %j � � O Icn _ I x'-74" 36"x 36"GROUND ACCESS TYP. I J LLJ z 0 I RE 5ETBACK/ACCE55 PAT " IN] " / 5HEET NAME I OF NEW 3-32 7 74 ��P��o A c,Gso�� SITE PLAN 'NOTE I .)THE ROOF SETBACK/PATHWAY SHALL NOT BE (fl DRAWING SCALE REQUIRED TO ROOFS WHEN OPPOSING OR 2 ADJACENT ROOF 15 ACCESS ROOF IN tPC�O 4 03443 �_� I/811 = I 1-011 ACCORDANCE WITH R324.G. I EXCEPTION OF OSS,ONP� 2020 NYS RESIDENTIAL CODE CONSTRUCTION NOTES 1 .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE SHEET NUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. FV-2 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1000059001 1 00007000 ?oho Sign Document ID:FOHNN7GHZFMYNGMBCWMKLSRW8YED1 MTVWQV4-DMRALE LEGEND DESIGN 4 DRAFTING BY: `EXISTING UTILITY METER ELEMENT ENERGY LLC MAW SERO ICE PANEL REVIEW BY J.M.NABCEP CERTIFIED NEW PV SUB-PANELS N 051112-129 A/C DISCONNECT COMBINER INVERTERS REVISIONS GND ELECTRODE 1 (1 o DESCRIPTION DATE REV MMPRV MODULE RAIL 04 �9� ORIGINAL 05-1C-2022 KING Zo ATTACHMENT POINT �2'0 Q 120 RAFTERS / 2400 0 150 ROOF PITCH ANGLE SUNRUN METER j> VENT /a n PLUMBING VENT %n SKY LIGHT CHIMNEY �j CONTRACTOR COMPOSITE SHINGLES / OWN/z, 15"FIRE SETBACK @R DGE/ / GOOD CONDITION POTENTIALTIALSHADING ISSUES TRIM/REMOVE AS NECESSARY I I i I I i i I I I I I 1 ELEMENT ENERGY, LLC. I I I 7470 SOUND AVE MATTITUCK, NY 1 1952 LICENSE # 43889-11 // LICENSE # 52089-ME 3'- I 4 / PROJECT NAME 101 - - ARRAY#I I W 8 MODULES 1" _ _ _ ARRAY#3 W 300 PITCH 2 jo'o ( G MODULES U 192°AIZIMUTH %, TE2 3CP PITCH L 1 02°AZIMUTH LU Q Zm — �� _ I In LuLU z - w :D0 G" x 3G"GROUND ACCESS TYP. , - - - - - - - I � - - - - _311 ARRAY#2 -74 LL Cn D (5 MODULES I - — — - - — — — �L O G°PITCH 'NOTE 252'AZIMUTH 1 .)THE ROOF SETBACWATHWAY SHALL NOT BE <_ 30 FIRE 5ETBACK/ACCE55 PAT REQUIRED TO ROOFS WHEN OPPOSING OR — _ — — — — — — — ADJACENT ROOF IS ACCESS ROOF IN ACCORDANCE WITH R324.G.I EXCEPTION OF SHEET NAME 2020 NYS RESIDENTIAL CODE ��OF NE CONSTRUCTION SUMMARY - MAIN MOU5E O (22) QCELL Q.PEAK DUO BLK ML-GI O.A+ 400 WATT PV MODULES CP�Pg� A G/li���,F �00� DETAIL (DIMENSIONS: 74"X 41 .1"X 1 .3") * [� (22) ENPHASE IQ7PLU5-72-2-U5 MICRO INVERTERS (52) ATTACHMENT POINTS @ 72" O.C. MAX. C7 UJ (229.3) LF IRONRIDGE XR 100 MOUNTING SYSTEM. DRAWING SCALE m 2 ROOF TYPE = ASPHALT SHINGLES (SINGLE LAYER) CONSTRUCTION NOTES X03443 1/8', = I 1-011 A� 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE OFESSI�NP� CJ WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH SHEET NUMBER MINIMUM NEMA 3R RATING. 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE PV-3 FIELD VERIFICATION. TAX MAP: 1000059001 100007000 Zoho Sign Document ID:FOHNN7GHZFMYNGMBCWMKLSRWBYED1MTVWQV4_DMRALE HEAVIEST ITEM DESCRIPTION ARRAY#I t-3 ARRAY#2 DESIGN f DRAFTING BY: LOAD CALCULATION ARRAY ELEMENT ENERGY LLC (ARRAY#3) RB Rid e Beam/Board 2"X 8" D. FIR 2"X 8" D. FIR R Roof Rafter 2"X G" D. FIR 24" O.C. 2"X 8" D. FIR 24" O.C. REVIEW BY J.M.NABCEP CERTIFIE MODULE WEIGHT(Lbs) 48.5O5 1 1 12-129 (D) Deckin I"X 8"TONGUE $GROOVE I"X 8"TONGUE * GROOVE #OF MODULES G (J) Ceiling Joist 2"X G" D. FIR 24" O.C. 2"X 8" D. FIR P, 24" O.C. (P) P1tch 30o Go REVISIONS TOTAL MODULE WEIGHT(Lbs) 291.0 of: NiE"rteV. �' K) Knee Walls 2"X 4" D. FIR 24" O.C. N/A DESCRPiioN DATE REV TOTAL LENGTH OF RAIL(Ft) 74.5CO�P _a0 A G0�P, H) Horizontal Span of(R) 73" MAX. 144' MAX. ORIGINAL 05-I G-2022 RAIL WEIGHT PER FOOT(Lbs) O.G8 TOTAL RAIL WEIGHT(Lbs) 50.7 t— W n r W #Of 5TRANDOFFS I G WEIGHT PER 5TRANDOFF(Lbs) 2 �O 103443 TOTAL STANDOFF WEIGHT(Lbs) 32 A (R5 ���S TOTAL ARRAY WEIGHT(Lbs) 373.7 S1( NA (D) (w POINT LOAD(Lbs) 23.4 (w (RB) CONTRACTOR TOTAL ARRAY AREA(Sct Ft) 128.5 (D) ARRAY DEAD LOAD(Lb�(5ct Ft) 2.9 ELEM ENT EN ERGY, LLC. WIND DESIGN SUBJECT TODAMAGE FROM 7470 SOUND AVE GROUND SEISMIC VANTER ICE BARRIER ROOD AIR MEAN (K) () MATTITUCK, NY 1 1952 SNOW S �d Topographic Special Windborne DESIGN Frost DESIGN UNDERLAYMENT FREEZING ANNUAL p wind debris line Termite` h IIAZARDSE c) LICENSE # 43889-h LDAD (mph) effecak region) zone" caTEG°Rvt Weathering° depihh TEenp4 REquIRED IroDExi TEMPI LICENSE # 52689-ME 20 140 NO NO NO B SEVERE 3 FT HEAVY 15°F YES ZONE X 599 51'F lAANUAL)DESIGN CRITERIA^ (H) (� Wier Summer Altitude Inchon Design Heating (J)-/ ElevaSon Latitude heating Cooling correction factor to design re temperature Cooling temperature PROJECT NAME temperature 108 FT 41°N 15°F 86°F 1.00 70°F 75°F 55°F [ARRAY#21 Wind Wind [ARRAY#I] Cooling Coincident Deity Winter SummerW I� temperature difference velocity velocity wet bulb range humidity humidity r \ W ` heating cooling `J z (� 11'F 15 MPH W 7.5 MPH 72°F MEDIUM(M) 40% 32 GR @50%RH Z � F-11 = For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 mis. ROOF FRAMING DETAIL Q a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength I z required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined � LU from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. Q b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction U 21 shall fill in the frost line depth column with the minimum depth of footing below finish grade. MODULE MOUNTING CLAMP LU C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. Q J d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. SOLAR MODULEn n _ e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York STAINLESS STEEL 3/8" n F- D State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also BOLT AND NUT W see Figure R301.2(1).] m O f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. (� g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the NP.IDGE ALUMINUM RAIL Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: i.The accompanying Flood Insurance Rate Map(FIRM), ALUMINUM°L"BRACKET ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. ALUMINUM FLASHING SHEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. It. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." ST�U CT U ISA L I. The jurisdiction shall fill in this partof the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F):' A5PHALT 5HINGLE ROOF j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method 511 G"x G"5TAINIf55 (Base 32°F)." 5TEEL LAG BOLT WITH k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 2 1/2"MIN THREAD jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION SEALED DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL 4500 "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) mAS NOTED . In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. It. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. SHEET NUMBER (`) See Figure R301.2(4)B. TAX MAP: 1000059001 100007000 MOUNTING DETAIL Zoho Sign Document ID:FOHNN7GHZFMYNGMBCWMKLSRW8YED1 MTVWQV4-DMRALE DE51GN 4 DRAFTING BY: SOLAR ARRAY ON MAIN HOUSE 8.8 kW ELEMENT ENERGY LLC (22)QCELL Q.PEAK DUO BLK-ML G 10+ 400 PV MODULES REVIEW BY J.M.NABCEP GERTIFIE (1)STRING OF(1 2)MICRO-INVERTERS 4�(1)STRING OF(10)MICRO-INVERTERS '(2)STRINGS TOTAL OF NEbV O5I 112-129 TO UTILITY GRID A G7G 0,�j REVISIONS `w DESCRIPTION DATE REV STRING #I ` �� * ' N ORIGINAL OS-16-2022 I UTILITY 40 L m t- ------------------- _ _ Z(P `_ I �---- �----' ---- ---' ---- O 103 �� 1 N I [� 344A� POINT OF INTERCONNECTION cc,ON`' PER NEC 240.2 I(B)(1)k 650.64(A) VJ LENC'TIi OF TAP CONDUCTORS STRING #2 S A L NOT XCEED O FT - - - - - - - - - - MICRO-INVERTER ENPHASE IQ7PLUS-72-2-U5 1 _ 71 - 07.5% 240 VAC. 1.21 A AX.OUTPUT POWER 29C VA CEC-WEIGHTED EFF. NEMA G.UL LISTED CONTRACTOR TYPICAL MAIN SERVICE D15CONNECT 240 V.200 A IRCUIT ABLE TY ELEMENT ENERGY, LLC. I 1 BPANCh CIRCUIT CABLE TYPICAL - 1 7470 SOUND AVE I 1 MATTITUCK, NY 1 1952 AC DISCONNECT LICENSE # 43889-H 1 5Q D D223NRB 1 240 VAC.GOA LICENSE # 52689-ME I 1 I NEMA 3R.UL USTED LI �G N I- LI (2)40 AFU5E5 0 DA 40A !1 1 I I PROJECT NAME 1 MAIN SERVICE PANEL N M I-PH.3-W 240 VAC I r---------- t' --- -------- ---------- 200A AC COMBINER BOX I I N 1 240 VAC.80 A LLJ NEMA 3R.ILL U5TED I I G - --i G ' ` z V,LLl N 'I I2)20 A DOUBLE POLE BREAKERS I v n I 1 ; I I I EXISTING GROUNDING Z I I I I ELECTRODE SYSTEM W J CII n II I n (z Z I I I L.L_ L-------------------------------------- -------------- ., V WIRE CONDUIT SCHEDULE CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% -jO I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DERATE DISTANCE n Ln ♦- 310.15(5)(3) 310.15(B)(2a)0c) J) Il D O INVERTERS COMBINER PANEL AWG#12 1 4 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I" 559C 0.84 1 I O FT 1.8% LLJ L 0 OR EMT 0 \ / COMBINER PANEL AC DISCONNECT AWG#8 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45QC 0.95 25 FT 1.3% 3 AC DISCONNECT MAIN PANEL AWG#6 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45C?C 0.95 10 FT 0.1% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTOR5 I.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90QC WET ENVIRONMENT. 690.8(B)(I)]: (Isc)'(#of 5trin s (I.56 19.GG A 3-LINE DIA. 3.)WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY [NEC g )' ) = Modules per String 13 MAX. AWG#12,ampacity'Temp Derate = 20.1 G A TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY, 20.1 6 A> 19.66 A,therefore DC wire size 15 valid. Modules per Inverter 1 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 20 COMPLY WITH NEC I 10.26. #2 Inverter Output Wire Ampacity Calculation 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 33.28 A Record low temp -I O0C FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTING5 AND ACE5SORIE5 TO FULFILL AWG#8,ampacity'(Temp Derate)'(Conduit Fill Derate) = 52.25 A Voc Temp Coefficient -0.24%/"-C DRAWING SCALE APPLICABLE CODES AND STANDARDS. 52.25 A> 33.28 A,therefore AC wire size 15 valid. DC SYSTEM SPECIFICATIONS CALCULATIONS 6.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation Operatincl Current 10.8 A =(#of 5trin 5)'(Im ) N .T.S . THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Inverter Max Amperage output' (1.25) 33.28 A 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#6, ampacity'(Temp Derate)'(Condult Fill Derate) = 71.25 A O eratin Volta e 37.I V =(#modules in series)'(Vm ) 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A> 33.28 A,therefore AC wire size 15 valid. Max.System Voltage 49.6 V = (#modules in series)'[(((-#.##%V/-C'.O 1)'(Lo Temp#VC-25))'(Voc))+(Voc)) SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 13.9 A =(#of 5trin 5)'(I5c)'(I.25)per Art. 690.8(A)(1) 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEED LUG AC SYSTEM SPECIFICATIONS 5NEET NUMBER OR I1-SCO G5L-4D13T LAY-IN LUG. Max AC Output Current 33.28 A 10.)THE POLARITY OF THE GROUNDED CONDUCTORS I5(positive/negative) FV-5 OR O eratin AC Voltacie 240 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000059001 1 00007000 ?oho Sign Document ID FOHNN7GHZFMYNGMBCWMKLSRW8YEDIMTVWUV4_DMRALE 'SERVICE METER O O DESIGN•DRAFTING BY: INSTALLATION NOTE ELEMENT ENERGY LLC SOLAR PV SYSTEM PHOTOVOLTAIC • • • • ( I ) ALL LABEL SHALL BE INSTALLED IN REVIEWBY05.112-129CERTIFIE 0 EQUIPPED WITH ! SOLAR BREAKER ` DC DISCONNECT ACCORDANCE WITH THE 201 7 NEC RAPID SHUTDOWN ® •• • REQUIREMENTS. RevlsloNs DE5CRIFION DATE REV •' •' (2) ALL LOCATIONS ARE APPROXIMATE AND ORCINAL y MAX SYSTEM VDC SOLAR AC LOAD CENTER - OUTSIDE � �DONOTRELOCATE T1pS . •. . VOLTAGE REQUIRE FIELD VERIFICATION. avERCu�DEV (3) LABELS, WARNING(5) AND MARKING IO SHALL BE IN ACCORDANCE WITH NEC O URN TRAPID SNUiDONM SNATCH TO 9 O THE'OFF-POSITM TO SHUT DOWN I 1 0.2 1 (B). PV SYSTEM AND REIXCE SIAVWZARDNTWAMY AC DISCONNECT POWER TO�SERUV)CEOB ALSO SUPPLIED (4) THE MATERIAL USED FOR MARKING FROM THE`T6LOCATED AS• "DAR`�� OMUST BE WEATHER RESISTANT, IN •�_ •'. ISCOIINECT6 LOCATED SOLAR AC LOAD CENTER - INSIDE O " "= - E COMPLIANCE WITH NEC 110.2 I (B)(3). CONTRACTOR 4 7 8 1 1 WARNING P°�^r � _ (5) THE PV SYSTEM CIRCUIT CONDUCTORS O O O O O "` SHALL BE LABELED INSTALLED IN ELEMENT ENERGY, LLC. THISEQUFM FMMBYMRTFLE DUALPOWERSUPF_, 7470 SOUND AVE SOURCES TO AL RNM of ALL ; -- COMPLIANCE WITH NEC 690.3 1 . gpEyS.plpyp , SOURCES:UTIUTYGRIC MATTITUCK, NY 1195 { I MSMU PLYOVERCURRENT ilVSOLAR LICENSE # 43889-H DEVICE,SHALL NOT ExCEE-- ELECTRIC SYSTEM LICENSE # 52G(59-ME CONDUIT - INSIDE BUILDING arYOFWSW LpWARNING �+ ING - ILM THIS SERVICE ITER PROJECT NAME _ IS ALSO SERVED BY AELECTRIC SHOCK HAZARD I TCOMBINER PSYSTIENIANEL PHOTOVOLTAIC SYSTEM TERMNN.S ON THE LINE AND LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS _ CONDUIT - OUTSIDE BUILDING ^" NTHE OPEN Pasrn°N ® U lLl ® z z 6� - ------ - WARNING — CZ >- DUAL POWER SUPPLY W W Z + PVSOSOURCES:BECTRICGSSYM SYSTEM I1 U C) MAIN SERVICE PANEL - OUTSIDE O W O A CAUTION SOLAR CIRCUIT L O O O -- CAUTION _ (S-) l� l Sana BECTMC SYS M CM ECI®' W (Y) O MAIN SERVICE PANEL - INSIDE POWER SOURCE I OUTPUT CONNECTION ® O SHEET NAME ELOCATE THIS OOVERCUIRRENTDEVICE of N E J o a c, O,� LABEL5 AC DISCONNECT/BREAKER 0 � � � w Tib W DRAWING 5CALE O 03 O9 ® oA� 703443 rP� N .T.5 . O SS10N SHEET NUMBER PV-G TAX MAP: 1000059001 100007000