Loading...
HomeMy WebLinkAboutStructural Report Letter ua eC s sr°uDraj engineers September 22,2023 Town of Southhold Building&Planning Departments Town of Southhold Annex Building 54375 Route 25 Southhold,NY 11971 Re: Design and failure modes for a 150-Ft.Slimline Pole (Pole Designed with a Theoretical Fall Radius of 72'-0") .,�..�.�...._�.. µ..,..__. —µM Site Name: Albertson Marine/Southhold 4 2023 Property Address: Budd's Pond Marina,Inc. 61405 Main Road u � ) fwnSouthold,NY 11971 Planning Board C&C Project No: T230140029.1.022 To Whom it May Concern: As detailed below,the 150-ft multi-carrier slimline pole designed by Carpenter&Cross—Structural Engineers and fabricated by AIIFasteners at the captioned site,and as depicted in the Preliminary Design prepared by Carpenter&Cross—Structural Engineers(Project Number T230140029.2.026 dated 9/21/2023),will comply with all applicable federal,state,and local structural standards. Final Construction Drawings will be provided at a later date. o le—Dolen StandardA and Failur MOOSE • This slimline pole structure was designed in accordance with the latest revision of the ANSI/TIA 222 Structural Standard for Antenna Supporting Structures, Antennas and Small Wind Turbine Support Structures unless otherwise requested by our customer.This standard has been approved by ANSI/ASCE, which has dealt with the design of antenna support structures for over 40 years.The TIA standard,based on provisions of this nationally known specification,has a long history of reliability.At its core philosophy is its first and foremost priority to safeguard and maintain the health and welfare of the public. • The TIA standard designates a minimum wind loading for each county in the United States.Carpenter& Cross uses the wind loading listed in the TIA standard unless a greater value is specified by our customer. Structures are also designed for radial ice at a code-specified reduced design wind loading. Code designated coefficients are used to ensure that the structure will survive the designed wind speed.The structure can usually survive even greater wind loads than the basic design wind speed because of these conservative coefficients. • Failure of a steel monopole occurs when a point is reached where the induced stresses exceed the yield strength of the material.At this point,the deflections induced in the material are no longer temporary. Hence,a permanent deflection in the monopole would exist. The term failure above refers to local buckling at a designated point on the pole.Local buckling does not cause a free-falling pole; rather it relieves the stresses from the pole at this location. Monopoles are flexible,forgiving structures,which are not generally susceptible to damage by impact loads such as wind gust or earthquake shocks. When local buckling occurs,a relatively small portion of the shaft distorts and"kinks"the steel.When the pole begins to bend,the exposure area is reduced and,therefore,the force due to wind is decreased as well. Even though buckling exists,the cross section of the pole is capable of carrying the entire vertical 5650 Blazer Parkway,Dublin,Ohio 43017 T 614 289-2977 www.CarpenterandCross.com Fall Zone Letter T230140029.1.022-Albertson Marine/Southhold 4-150 Slimline Pole September 22,2023 Page 2 load.Therefore,wind induced loads would not conceivably bring this type of structure to the ground due to the excellent ductile properties,design criteria,and failure mode. In addition, the monopole can be designed to theoretically fail at the 78' elevation by purposely over designing the pole sections below this point. In the unlikely event the pole was to fail at this point, the significant loading reduction caused by the removal of the tower wind area and weight above would greatly reduce any chance that the remaining tower would collapse,thereby providing a theoretical failure radius of approximately 72'-0"for the 150-ft AGL slimline pole. We are aware of Southold Town Code section 280-70G, which generally requires a "fall zone" of an area surrounding the proposed antenna support structure by two times the height of the structure.However,we submit that the Town allow the smaller fall zone as stated in this letter. Monopole Coordinates: 41°4'33.69"N,721 24'21.72"W I hope these comments address any issues that you might encounter relative to the anticipated performance of monopole structures and quality of steel fabrication.If you have additional questions or comments,I may be reached at(614)289.2977. Sincerely, Christopher M.Cullinan,P.E. fCarpenter&Cross LLC CCullinan@CarpenterandCross.com 9/22/2023 5650 Blazer Parkway,Dublin,Ohio 43017 T 614289-2977 W28yX&W=, C=UdCEMU= Fall Zone Letter