Loading...
HomeMy WebLinkAbout49632-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49632 Date: 8/31/2023 Permission is hereby granted to: Laurel Stone Silly Plus Inc ... ..... .................. 6865 Route 25 ..... ......... ...... ._........ ........................._........._. .................._...._._ Mattituck NY 11952 To: Modify an existing wireless telecommunications facility to add cabinet, antennas & equipment as applied for per Planning Board approval (T-Mobile). At premises located at 7055 Route 25 Laurel w.............. ... .... .. w ......... ......................................_ SCTM # 473889 Sec/Block/Lot# 122.-6-35.4 Pursuant to application dated 9/8/2022 and approved by the Building Inspector. To expire on 3/1/2025. Fees: WIRELESS COMMUNICATIONS -MODIFICATIONS $500.00 CO- COMMERCIAL $50.00 ...m.....................................__�.......... _....� Total: $550.00 �&�. ......................�._..._............................... ..................... .......................... _.. Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT i Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 lett is:// % . outholdtowiiii .O Date Received APPLICATION R BUILDING PERIMIT For Office Use Only �-9 PERMIT NO. �� Building Inspector: .0 . . Applications and forms must be filled out in their entirety.Incomplete BUILDING DEP IJTH . �T®�PUEU OF SC?UTNC°l..:a applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name:Laurel Stone Supply =SCTM#1000-122.00-06.00-035.004 Project Address:7055 Main Road, Mattituck NY 11952 Phone#:631-298-7021 Email::::: Mailing Address:7055 Main Road, Mattituck NY 11952 CONTACT PERSON: Name:Ryan Bourke / Complete Development Services Mailing Address:898 North Broadway, Suite #5 Massapequa NY 11758 Phone#:631-896-2392 Email:ryan.bourke completedevs.con DESIGN PROFESSIONAL.INFORMATION: Name:William F Collins Mailing Address:12-1 Technology Drive, E. Setauket NY 11733 Phone#:631-689-8450 Email:neil.macdonald@wfcaia.com CONTRACTOR INFORMATION: Name:Milicia Electric Corporation Mailing Address:87 Eads Street, West Babylon NY 11704 Phone#:516-694-0751 1Email:jlavalle@miliciaelectric.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition 1RAlteration ❑Repair ❑Demolition Es ' be( 6tofProject: ❑Other $ , Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes *NO 1 agtdfli ul` ��������y@!� .�rcf r ( ,TIfu�, ,4r�,�Pl Existing use of property. slnnrs �o"w wwke4asfa6ftyhmekollaa. Intended use of property Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes RNo IF YES, PROVIDE A-COPY. ef r Application p e r` "fo her Schaaf pp Submitted B y(print Authorized Agent ❑Owner Signature of Applicant: I Date: ��y�z z / x STATE OF NEW YORK) SS: } COUNTY OF Suffolk ) Christopher Schaaf being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Authorized Agent (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this L 9+ day'of 20 22- Y`�1 N tart' Public JENNIFER DO,NOHUE ; Nom public-Make of Now York I No01006211004 PROPERTY OWNER AUTHORIZATION In Suffolk County 61 (Where the applicant is not theowner) CoMmlaalon Expires OW08120 ` a residing at dhereby 1 5`z y authorize to Christopher Schaaf / T ohiie oere apply on my behalf to the Town of Southold Building Department for approval as de "bed herein. ...... Owner''Signatuhe Date W c->, M- AA Print Owner's Name 2 MAILING ADDRESS: PLANNING BOARD MEMBERS �� SO// P.O. Box 1179 DONALD J.WILCENSKI Southold,NY 11971 Chair OFFICE LOCATION: Town Hall Annex JAMES H.RICH III & 54375 State Route 25 MARTIN SIDOR PIERCE RAFFERTY (cor.Main Rd. &Youngs Ave.) AMELIA JEALOUS-DANK Southold,NY Telephone:631765-1938 www.s outholdt ownny.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD August 22, 2023 AUG 3 1 2023 Ryan Bourke c/o T-Mobile Northeast LLC 1.1t„J DING „ Complete Development Services TONXN V x,01-TIJ 11 898 North Broadway, Suite #5 Massapequa, NY 11758 Re: SEQRA Classification, Determination, &Approval T-Mobile Colocation @ Laurel Stone Located at 7055 Main Road, Mattituck, NY SCTM# 122.-6-35.4 Dear Mr. Bourke: The following resolutions were adopted at a meeting of the Southold Town Planning Board on Monday, August 21, 2023: WHEREAS, this amended wireless communication facility application is for a proposed T-Mobile colocation between 60'-80' a.g.l. on an approved existing 110' tall concealed monopole and the addition of associated ground equipment within a 220' sq. ft. lease area. There are two carriers already located on this tower along with equipment from the Mattituck Fire District. There are also ±5,078 sq. ft. of existing buildings including a stone supply yard and associated accessory structures, all on 1.6 acres in the General Business Zoning District; and WHEREAS, on September 8, 2022, Ryan Bourke, authorized agent, submitted a Building Permit application to the Building Department; and WHEREAS, on September 15, 2022, the Planning Board authorized CityScape Consultants to review the application for completeness of technical information; and WHEREAS, on September 27, 2022, CityScape notified the applicant of missing technical items to be addressed; and Southold Town Planning Board P a g e 12 August 22, 2023 WHEREAS, on April 11, 2023, Ryan Bourke, authorized agent, notified CityScape Consultants that the applicant was compiling the required documentation and that the Tower owner requested a relocation of ground equipment that required reconfiguration; and WHEREAS, on May 8, 2023, Ryan Bourke, authorized agent, submitted technical data to Cityscape Consultants; and WHEREAS, on May 12, 2023, the Planning Board due to the nature of the proposed colocation notified the applicant that a Site Plan application and associated fees were required by Southold Town Code; and WHEREAS, on July 6, 2023, Ryan Bourke, authorized agent, submitted a site plan application for review; and WHEREAS, on July 6, 2023, Ryan Bourke, authorized agent, pursuant to 28+0- A(4) of the Town Code, submitted a check in the amount of$8,600 into an escrow account with the Town Comptroller's Office to cover the cost of the Technical Consultant's Review; and WHEREAS, on July 6, 2023, the Planning Board authorized CityScape Consultants to proceed with the work as outlined in the agreement; and WHEREAS, at a Work Session on August 21, 2023, the Planning Board accepted the application as complete for review; and WHEREAS, pursuant to Southold Town Code 280-131(H), this application is eligible for a waiver of the requirement for a public hearing because the colocation will not be visible as the new antennas and cables will be placed inside the already existing monopole, with no extension of the height of the pole„ and ground equipment will be placed inside an already existing fenced-in compound; and WHEREAS, at a Work Session held on August 21, 2023„ the Planning Board reviewed the report issued by CityScape Consultants on August 2, 2023; and, determined that the action fallls within the ECC regulations of the Middle-Class Tax Relief and ,fob Creation Act of 2012. Therefore, it is recommended for approval with the understanding that the proposed cable (see Conditions below) will be installed inside the monopole shaft; and WHEREAS, at a Work Session held on August 21, 2023, the Planning Board fbund that all applicable requirements of the Site Plan Regulations, Article XXIV, 280 —Site Plan Approval of the Town of Southold, have been met; and WHEREAS, the Southold Town Planning Board, pursuant to State Environmental Quality Review Act (SEAR ) 6 ISI CRR, Part 617, has determined that the proposed action is an Unlisted Action as it does not meet any of the thresholds of a Type I Action, nor does it meet any of the criteria on the Type 11 list of actions; and Southold Town Planning Board P �a, g e 13 August 22, 2023 WHEREAS, the Planning Board performed an uncoordinated review of this Unlisted Action pursuant to 6 NYCRR Part 617, Section 617.7 of the State Environmental Quality Review Act (SEQRA); therefore be it RESOLVED, that the Southold Town Planning Board has determined that this proposed action is an Unlisted Action under SEQRA as described above, and be it further RESOLVED, that the Southold Town Planning Board, as Lead Agency pursuaritto the State Environmental Quality Review Act, makes a determination of non-significance and grants a Negative Declaration; and be it further RESOLVED, that the Southold Town Planning Board hereby waives the public hearing as noted above; and be it further RESOLVED, that the Southold Town Planning Board, grants an approval with conditions to the site plan entitled "T-Mobile Northeast LLC, Laurel, 7055 Main Rd. (NY-25'), NSD @ Site No. LI-03-1 10-K, prepared by Neil Alexander Macdonald, Registered Architect, dated April 20, 2022 and last revised April 11, 2023, and authorizes the Chairman to endorse the Site Plan including the following plans: T-1 Title Sheet A-7 Equipment Details A-1 Architectural Site Plan&General Notes A-8 Antenna Information &Antenna Mounting A-2 Enlarged Compound Plan & Site Details Details A-3 Enlarged compound Plan & Site Details A-9 Antenna Information A-4 Canopy Framing Plan and Typical Details A-10 Generator, Transfer Switch Detail & A-5 West Elevation Electrical Riser Diagram A-6 Equipment Cabinet Details Conditions: A. Prior to endorsement of the site plan, a use certification must be obtained from the Chief Building Inspector as required by Town Code. B. Prior to the issuance of a building permit: 1, Ensure the osprey nest located on top of the existing monopole is removed in accordance with all state and federal requirements. 2. A preventative device shall be installed on top of the pole and in other locations if found to be necessary to prevent the nesting of osprey, and other birds and wildlife. C. Prior to the issuance of a certificate of occupancy: 1. The three trees planted along the street, at the portion of the lot abutting Route 25, rnust be replaced in accordance with the original site plan approval for this wireless facility granted on June 29, 2020. D. Additional conditions of approval (ongoing): 1. All of Applicant's feed lines/cables shall be installed inside the monopole structure. P �, g � Au ust 22, 2023 Southold Town Planning Board g 2. No exterior lights were reviewed or approved in connection with this site plan. Any exterior lights on or around the outside of this area must be reviewed and approved by the Planning Board prior to installation and must meet Town Code §172 Lighting. 3. All ports shall remain sufficiently sealed to prevent access by birds and other wildlife. 4. Survivability of the three trees planted along the street, at the portion of the lot abutting Route 23, shall be guaranteed and maintained for the life of the installation. 5. The facility shall remain secured and protected from unauthorized personnel. Please note the following requirements in the Southold Town Code relating to Site Plans: • Approved Site Plans are valid for eighteen months from the date of approval, within which time all proposed work must be completed, unless the Planning Board grants an extension. • Any changes from the Approved Site Plan shall require Planning Board approval. • Prior to the issuance of a Certificate of Occupancy, the Planning Board must inspect the site to ensure it is in conformity with the Approved Site Plan and the conditions above, and issue a final site inspection approval letter. Should the site be found not in conformance with the Approved, Site Plan, no Certificate of Occupancy may be issued unless the Planning Board approves the changes•. A copy of the Approved Site Plan is enclosed for your records. One copy will also be sent to the Building Department and the Town Engineer/highway Department. If you have any questions regarding the above, please contact this office. --m,8esp tf fly Donald J. Wilcenski Chairman Encl. cc: Michael Verity, Chief Building Inspector, with map LEGEND saga�ce max mx a �.mxxa [ _sa �+xs xcrs 1 Y.+ia 1 E[ rte a. Om L1$11 m81B) k' v X49":3 49'E 60 uss ND L s _ a BMWODUME RM�t reg J , _ -UN rix m aa: et. 1! g fin t LI Z �1 VIV t- tN55roz,49,w atm a �' � �a• lam® F L-J ' t SU:i'Yt:OF PROPERTY E[ _ w mom' Ir.7 ' rU A�D CERTIFICATE OF LIABILITY INSURANCE I DATE(MM/DD/YYYY) 09/07/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER C�gNTPACT _. Antllola DiGennaro �v_..�.wwvv...... DiGennaro&Associates,Inc. PHONE ,t 631' 243'9014 X 888 315 3750 999-32 Montauk Hwy Suite#421 ,ss, at�rnaro1� ol.com.com Shirley NY 11967 N RERn AFFORDINO••COVERAGE _....... MAIC, ..................................�..�.._...�..�............ N R Hartford Ins Co 41513 INSURED INSURER B• Hartford Ins Co of The Midwest 23809 Milicia Electric Corp.. IN UR Rc. AIG Property Casualty Co 19402 I, -;RD. The Travelers Indemi Co 19445 87 Eads Street N ERE: ... .. 24260 West Babylon, NY 11704 1INSUMIRF; COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES,LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ..__����� .........._ ....._.. _� _.,_.....� INSR ADDL UBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE L B LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ a 1,000 000 A CLAIMS-MADE DAMAGE TO RENTED OCCUR PREM1SES(Eaorzurrence) 100 000 x Contractual Liability X 12SBAAD1391 06101/2022 06/01/2023 MEDEXP(Anyoneperson) $101000 _ x Prima _&Non Contributory PERSQNAL�ADv wJURY 1000,000 XEN1POLGICYEGATEPRO-APPLIES PER: GENEPRODUGTSGCOMPAOP AGG, ,$2 OOOeOOO �_ 0 TH $ COMBINED SIN LE AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1,000000 �......zmm A X ANY AUTO BODILY INJURY(Per person) m$ ALLOWNED SCHEDULED 12UECGA0393 06/01/2022 06/01/2023 BODILY INJURY(Per accident) $ AUTOS AUTOS - -•--- - NON-OWNED PROPERTY DAMAGE $ X HIRED AUTOS X AUTOS ).............-••• --- - X UMBRELLA LIAB X OCCUR EACH OCCURRENCE ._---...... $5,000,,000 A EXCESS LIAB CLAIMS-MADE''.. 12SBAAD1391 06101/2022 06/01/2023 AGGREGATE ,,,,,,,,,, ,„ITITITITITITIT,�5�000,000 X TIN 10,000 Follows Form $ WORKERS COMPENSATION X PaERs OTH- ANDEMPLOYLIABILITY Y/N ANY PROPRIETORIPARTNER/EXECUTIVE EACH ACCIDEN[T � $1,000,000 B OFFICER/MEMBER EXCLUDED? N/A12WECKZ6547 06/01/2022 06/01/2023 (Mandatory in NH) E L DISEASE-EA EMPLOYEE $1,000,.000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 D Excess Liability ZUP-51N20885-19-NF 09/13/2021 09/13/2022 5,000,000 Occurrence C Pollution Liability CPO 28802609 07/19/2022 07/19/2023 1,000,000 Occurrence DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Certificate holder is named as a additional insured with respect to work done by the insured on their General Liability Policy CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Po Box 1179 SOuthhold, NY 11971 AUTHORIZED REPRESENTATIVE <CNV ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD LK qy"orl'RIworkers' CERTIFICATE OF INSURANCE COVERAGE �Tc Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that Carrie 1a. Legal Name&Address of Insured(use street address only) 1b. Business Telephone Number of Insured MILICIA ELECTRIC CORP. 631 6940751 87 EADS STREET WEST BABYLON, NY 11704 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 800003633 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 53095 Route 25 3b.Policy Number of Entity Listed in Box"ll a" Po Box 1179 DBL432238 Southold NY 11971 3c.Policy effective period 01/01/2022 to 12/31/2023 4. Policy provides the following benefits: A. Both disability and paid family leave benefits. ®' B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above.. Date Signed 9/7/2022 By C � U/ GG�IU/ _ (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B, 4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board (Only if Box 413,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 1111111�1 111111111111111111111111111 DB-120.1 (12-21) Additional Instructions for Form 1313-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1 a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law. The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage (Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c, whichever is earlier. This Certificate is issued as a matter of information only and confers no rights upon the certificate holder. This Certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder, the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand and twenty-one, the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand eighteen, the payment of family leave benefits for all employees has been secured as provided by this article. D13-120.1 (12-21) Reverse Workeirs" CERTIFICATE OF O"ed NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Milicai Electric Corp 631 694 0751 87 Eads Street 1c.Nos unemployment Insurance Employer Registration Number of West Babylon NY 11704 Insured Work Location of Insured(Oaiy required ffco siege is specrficafiy knifed to 1d.Federal Employer IdentHicatlon Number of Insured or Soclal Security cedain iocallons in Afew York Slate,to.,a Wrap-Up Policy) Number 80 0003633 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Garner (Entity Beim Listed as the Certificate Holder) Hartford fns Co. Town of Southold 31T Policy Number of IT Listed In Box"la' 53095 Route 25 12WECKZ6547 Po Box 1179 Southold NY 11971 3c.Policy effective period 10112099 to 06/01/2023 3d.The Proprletor,Partners or Executive Officers are ❑ included.(Only check box Ir su paMerdolfli indudsd) ❑ ala excluded or certain partnersiotf`icers exclucled. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"l a"for workers' compensation under the Now York state workers"Co npansai iorr Law,(To use this form,.Now York(IT roust Ilse listed under Ut 3A on time INi"O6111'ATION PAGE of IT workers!compensalton Insurance policy). The Insurance Caller or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box-Z. The insurance comer must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other then nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is veld for one year after this form Is approved by the insurance carrier or Its licensed agent,or until the policy expiration date listed In box"3c",whichever Is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or atter"ilte coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those containedin the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Plesse Note:Upon cancellation of the workers'compensation poilc r Indicated on this form,it the business continues to be named on a permit,license or contract issued by a cartiflcate holder,the business must provide that ceritficata holder with a now CarWkcft of Workers'Compsnsatlon Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penally of perjury,I certify that I am an authorized representative or licensed agent of the Insurance cancer referenced above and that the named insured has the coverage as depicted on this form. Approved by: Anthonv Di nnaro t rcarrca of aut ra tie or tioeneed apent of Insurance canter) Approved by. 09/07/2022 4pr�atura) (Date) Title: u Telephone Number of authorized representative or licensed agent of Insurance carrier: 631 243 9014 Please Not@:Only Insurance carriers and their licensed agents are authorized to Issue Form IT 05.2.Insurance brokers ars NW author, to loom It IT 05.2(9-17) www.web.ny.gov `t9 1�3a - �sseS�o s Art& tin LAUREL T Mubil 7055 MAIN RD (NY-25) LAUREL, NY 11952 Northeast LLC NSD @ SITE NO. LI-03-1 10-A A R C H I T E C T S 12.1 TECIINOLO lY DRIVE.SETAL;KET.NY 11731 3500 SUNRISE HIGHWAY, GREAT RIVER, NY 11739 WFC PROJECT NO. 22-15175 P.631.689.8450 IT 631.689.8459 1—f.m— % DRAWING INDEX LOCATION MAP SITE INFORMATION NO. LATEST ISSUANCE f LOCATION OF EQUIPMENT: GROUND DWG. DRAWING TITLE INITIAL ISSUANCE t 220 SQ.FT. T-1 TITUESHEET 1 04/20/22 1 4 1 04/11/23 EQUIPMENT SQUARE FOOTAGE: C-y 4q SCOPE OF WORK: ARCHITECTURAL T, CE BRIDGE. INSTALL(1) EQUIPMENT: INSTALL NEW CONCRETE PAD. INSTALL NEW I 04/20/22 4 04/11/23 NEW 8160 CABINET. INSTALL(1)NEW 6160 CABINET.INSTALL(1)NEW A-1 ARCHITECTURAL SITE PLAN&GENERAL NOTES iv PPC.INSTALL(1)NEW VZW AAV. INSTALL(3) 75 ./ I 'f, NEW RADIO 4480.INSTALL L, 4 04/11/23 WEATHER CANOPY. INSTALL(1)NEW A-2 ENLARGED COMPOUND PLAN&SITE DETAILS (3)NEW RADIO 4460. INSTALL(2)NEW RADIO 8863.INSTALL(3)NEW 04/20/22 QUAD DIPLEXERS. INSTALL NEW N1. 48KW DIESEL GENERATOR. INSTALL(1)NEW GENERATOR AUTOMATIC No. :9 TRANSFER SWITCH. A-3 ENLARGED EQUIPMENT PLAN 04/20/22 4 04/11/23 _i ISSUED ANTENNA: INSTALL(6)NEW COMMSCOPE FVV-65B-R3 ANTENNAS.INSTALL(3) A-4 CANOPY FRAMING PLAN AND TYPICAL DETAILS 04/20/22 4 0 04/20/22'04/11/23 1 04/25/22 REVISEFOR REVIEW D PER RFDS NEW SMART BIAS TEE. INSTALL(24) NEW 7/8"COAX CABLES. 2 05/27/22 REVISED PER RFDS A WEST ELEVATION 0 4 04/11/23 4/20/22 3 08/30/22 ISSUED FOR FILING -5 4 04/11/23 REVISED PER COMMENTS 04/20/22 4 04/11/23 ELITE TOWERS LP(516)410-8730 A-6 EQUIPMENT CABINET DETAILS PROPERTY CONTACT: 4 04/11/23 M, UTILITY CONTACT: (516)545-2242 LIPA A-7 EQUIPMENT DETAILS 04/20/22 04/20/22 4 1 04/11/23 A-8 ANTENNA INFORMATION&ANTENNA MOUNTING DETAILS T-MOBILE NORTHEAST LLC SITE LESSEE APPLICANT: 04/20122 4 04/11/23 1 DAN GUSTAFERRI A-9 ANTENNA INFORMATION NOTES, DEVELOPMENT MANAGER: 41 A j;. NO CONSTRUCTION OR BIDDING IS TO PROCEED UNLESS IAGRAM 1 A-10 GENERATOR,TRANSFER SWITCH DETAIL AND ELECTRICAL RISER D 04/20/22 4 04/11/23 PLANS INCLUDE THE STATEMENT'ISSUED FOR ii RF ENGINEER: KUMAR NAREN CONSTRUCTION"IN THE DESCRIPTION COLUMN ABOVE. PRIOR TO BIDDING OR CONSTRUCTION,CONTRACTOR 58-43.7268"(NAD 83) N 40 MUST ALSO CONTACT WFC TO CONFIRM THEY ARE IN LATITUDE: POSSESSION OF THE LATEST PLANS. W 72*32'49.8372"(NAD 83) LONGITUDE: AREA 0- -WOR< ELEVATION: ±23'(NGVD 29) DISTRICT: 1000 KEY MAP SECTION: 122.00 BLOCK: 06.00 V LOT: 035.004 ZONING JURISDICTION: TOWN OF SOUTHHOLD I NOTE: COORDINATES AND ELEVATIONS REFERENCED ABOVE WERE SUPPLIED BY T-MOBILE NORTHEAST LLC.THE ARCHITECT MAKES NO WARRANTIES OR GUARANTEES RELATIVE TO THEIR T- ..Mobile- ACCURACY OR COMPLIANCE WITH FAA 2C TOLERANCE. Northeast LLC �A 300 SU"OF MGHW AYrRM'rMVMNYU7" 9 APPROVAL REVIEW FORM LAUWL DEVELOPMENT MANAGER: NSD DAN GUSTAFERRI 7055 MLiAIN-03-11G-A RD W-251 RF ENGINEER: LAUREL,W MM SITE KUMAR NAREN PTLE. TITLE SHEET PROJECT MANAGER: MARJORIE LINDSAY pv DATE. 0.4/13/22 LEASING SPECIALIST: -ROJECT NO: 22-15175 c!i1^R ':T COMPLETE DEVELOPMENT SERVICES IRA.'31 ci CH.ECKED By w RFDS DATED: 05/27/22 DRAFT) LANDLORD: ELITE TOWERS LP DRAWING NO: T- 1 'THE LANDLORD APPROVES THE LOCATION,MODIFICATION,AND INSTALLATION OF THE ANTENNA FACILGIES AND ASSOCIATED EQUIPMENT AS SET FORTH IN THESE CONSTRUCTION DRAWINGS GENERAL NOTES: 1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH J PROVISIONS OF LOCAL, STATE, AND FEDERAL, LAWS. ORDINANCES, AND REGULATIONS WHEREVER APPLICABLE. 2. EACH CONTRACTOR SHALL BE HELD TO HAVE VIS TED THE SITE AND TO HAVF VFRIFIFD At L EXISTING CONDITIONS PRIOR TO SUBMISSION i OF BID. P 3. IN A_L CASES, DRAWINGS SHALL NOT BE SCALED FOR INFORMATION. FIGURED DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. 4. CON-RACTOR SHA_L VERIFY AND BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND JOB CONDITIONS, AND SHALL NOTIFY THE A R C H I T E C T S LANDN/FSUFFOLKCOUN7YWgTERAUTNORITY ARCHITECT OF ANY DISCREPANCIES, CONFLCTS, AND/OR OMISSIONS 12.1 TECHNOLOGY DRIVE,SEIAUKET,NYt1733 S.FOLK COUNTY ER WHICH WOULD INTERFERE WITH THE SATISFACTORY COMPLE ION OF P 631.689.8450 1 F.631.689.8459 1—.Wr.,..mm ZONE 2 _ e ��- THE WORK. SHOULD HE =AIL TO FOLLOW THIS PROCEDURE AND , R.O.W, CONTINUE WITH THE WORK, HE SHALL ASSUME ALL RESPONSIBILITY " (PER DEED L 12571 CP 838) AND LIABI_ITY ARISING THEREFROM. NEW T-MOBILE COMPOUND 5. ALL ITEMS OF WORK IDENTIFIED ON THE DRAWINGS BY NAME, NOTE. OR MATERIAL DESIGNATION ARE NEW, UNLESS OTHERWISE NOTED. AREA. SEE A-2 FOR it ADDITIONAL INFORMATION 6. ALL NEW MA-CRIALS AND INSTALLATIONS SHALL BC IN ACCORDANC- 549'13'49"E --------------- WITH THE MANUFACTJRERS LATEST PRIN-ED SPEC FICA-IONS, AND � �L;=- '�:� "•;,'�_' �-- WITH ALL APPLICAB_E CODE REQUIREMENTS. •, ,i' 439.35' /. ALL WORK SHALL BE 'ERFORMED IN ACCORDANCE WITH BES( 1E• F"' - vii, SUBJECTPARCEL STANDARD TRADE PRACTICES. EACH TRADE SHALL COO-ERATE WITH mr•, 7 , S.C.T.M. 1000-122-06-35.4 OTHER TRADES TO FACILITA E JOB SC-IEDULING AND COMPLETION. ZONE 8. PROPRIETARY NAMES IDENTIFYING ITEMS OF WORK ARE USED TO .,+` 1•°yi �-e,.` ' r� PARCEL AREA(DEED)= DES GNATE THE STANDARD OF CONSTRUCTION. ITEMS OF EQUAL �'� �... ,. �•�' Ap 71,725 SQ.FEET QUAL TY MAY BF SUBMITTED FOR THF ARCH TFCTS REVIEW AND ' � 1.6466 ACRES APPROVAL. PARCEL AREA(NET LESS SCWA)= 9. EACH CONTRACTOR SHALL BE RESPONSIBLE FCR ANY DAMAGE TO NO. DATE SUBMISSION SfCr 71,640 SQ.FEET _ Q ADJO NING REMAINING AREAS AS A RESULT OF I-IS WCRK, AND 0 04/20/22 ISSUED FOR REVIEW OR 1 04 25/22�REVISED PER REDS C• r 1.6446 ACRE anc rF SHALL REDAR DAMAGED SURFACES TC THEIR PRE-EXISTING 2 05/27/22,REVISED PER RFDS CONDI IONS OR AS MAY BE REQUIRED TO COMPLE-E THE ENTIRE 3 04/30/22'ISSUED FOR FILING O m 340' X I w eO O SCOPE OF THE WORK. PHOTOGRAPH ALL AREAS OF NEW WORK 4 Oa/n/23 REVISED PER COMMENTS w ' I w w l e PRIOR -0 BEGINNING CONSTRUCTION. 4 K Q a 3 (STORY BRICK 8 BLOCK m BUILDING#7055 ,,�, > N 10. ALTERATIONS TO EXISTING WORK SHALL BE PATCHED AND FINISHES, p F- o $ ° z AS NECESSARY, TO MATCH EXISTING CON-IGUOUS SURFACES OR m� I v eo.r N=W FINISHES SHOWN. 2570RY m � w < 11. AT TH= COMPI FTION OF FACH WORKDAY, FACH TRADE SiAL_ BE c p F BLDG. Q p RES'ONSIBLE FOR CLEAVING UP THEIR WORK. RUBBISH REMOVAL ZO ' qy. a o a o SHALL BE DONE IN A DIST INHIBITIVE FASHION, AND THE JOB SITE NOTES : J I rn ISI TALL B FREE OF ALL DEBRIS AND BROOM CLEAN UPON NO CONSTRUCTION OR BIDDING IS TO PROCEED UNLESS — t2ml I �g --�' PLANS INCLUDE THE STATEMENT"ISSUED FOR iN COMPLETION. CONSTRUCTION'IN THE DESCRIPTION COLUMN ABOVE. 12. CLEAN ALL FLOORS, WAL-S, DOORS, MISC_ GLASS, ETC. LEAVING PRIOR TO BIDDING OR CONSTRUCTION,CONTRACTOR n MUST ALSO CONTACT WFC i0 CONFIRM THEY ARE IN JOB FREE OF DUST AND DEBRIS, PRIOR TO PROJECT COMPLETION. � POSSESSION OF THE LATEST PLANS. 77 00' N45° W m 13. EXISTING EQUIPMENT AND MATERIA_S TO BE REMOVED, WHICH ARE w N55°02' 29'49" <EY'LAI 1 NOT REQUIRED TO BE RELOCATED OR RETAINED BY THE OWNER, °• 3300' SHALL BECOME THE PROPERTY OF THE CCNTRACTOP. AND BE AREA o=WOR< A o REMOVED PROM'TLY FROM THE PREMISES. -= �. 1L. INDICATIONS OF WORK -0 BE REMOVED ARE GENERAL ONLY, AND z - can:Ec; ARE NOT INTENDED TO SHOW ALL ITEMS WHICH MAY REQUIRE _ --=_:- EXISTING NON-UTILIZEDREMOVAL SUCi ITEMS SHALL BE REMOVED, RELOCATED, AND/OR N37°59,1g"w DIESE_ TANK BY OTHERS REINSTALLED, AS REQUIRED FOR INSTALLATION OF NEW WORK. 15. T-1ESE DOCUMENTS DO NOT AUTHORIZE DETERMINING THE _ I-STORYCONCRETE 3 EXISTING FIRE DEPARTMENT PRESENCE, NOR THE REMOVAL OF ASBESTOS OR OTHER HAZARDOUS Q BLOCCKSHED n EQUIPMENT AREA MATERIALS. IF DURING THE COURSE OF TIE PROJECT, ASBESTOS OR OTHER HAZARDOUS MATERIAL CONTAMINA70N IS SUSPECTED, THE 1 cl 215EXISTING AT&T DIESEL GENERATOR A-5CONTRACTOR SHALL NOTIFY THE CARRIER'S PRO ECT MANAGER cc 3T m WITHIN 24 HOURS. CONTRACTOR SHALL SUSPEND WORK IN THE C y�® EXISTING AT&T EQUIPMENT AREA AFFECTED AREA UNTIL SUCH A TIME THAT SAID AREA S CERTIFIED ®® Ho i■1 CONTAMINA ION-FREE. IN THE NTERIM, THE CONTRACTOR SHALL Northeast LLC EXIS-TNG PRO'ERTY LINE ENDEAVOR TO RESCHEDULE WORK TO AREAS UNAFFECTED BY 3509SUNMEHIGHWAY,GYP.A7'17YEY,NY117D SUSPECTED CONTAMINATION IN ORDER TO MINIMIZE DELAY TO THE PROJECT SCHEDULE. 'RIOR TO SJSPENDING WORK MAKE ALL AREAS LALFa OF WORK SAFE AND WHERE NECESSARY WATERIROOF. NSD 16. AL_ MECHANICAL AND ELECTRICAL WORK SHALL BE IN FU_L CONFORMANCE WITH N.Y.S. UNIFORM FIRE PREVENTION AND U-03-110-A BUILDING CODE, AND ALL CTHER APPLICAB_E CODES AND 7056 MAN RD W-259 REGULATICNS. LAUREI,NY VW 17. ELECTRICAL WORK SHALL BE INSTALLED BY AN ELEC-RICIAN, 71,1E: LICENSED IV NEW "ORK STATE AND IN SUFFOLK COUNTY, IN ARCHITECTURAL SITE PLAN ACCORDANCE WITH NEW YORK STATE AND NATIONAL ELECTRICAL &GENERAL NOTES CODES. A NEW YORK BOARD OF FIRE UNDERWRITER'S CER-IFCATE SHALL BE OBTAINED FOR A_L ELEC-RICAL WORK, AND SUPPLIED TC DATE, 04/13/22 THE OWNER AND ARCHITECT. =ROJECNO: 22-151/5 18. PROVIDE ANY AND ALL TREATED WOOD BLOCKING/BACKING OR 14 DRAWN BY: CJ GA. GALV. =1A- STOCK SACKING AS REQUIRED TO FNSIRF PROPER CNECKEO BY: MA AND ADEQUATE SUPPORT (IN COMPLIANCE WITH NEW YORK STA E R-DS DATED 06/27/22 CRAFT) BUILDING CODE MINIMUM LOADING REQUIREMENTS WHERE DRAWLNGNO 1 ARCHITECTURAL SITE PLAN NORTH APPLCABLE) CF VARIOUS ITEMS INCLUDING, BUT NOT NECESSARILY e 1 LINITED TO HANDRAILS, SHELVING, CABLE TRAYS, CONDUITS, ETC. , ` 1 SCALE: 1"=5O 19. ADA COMPLIANCE: THE FACILITY IS A NORMALLY UNOCCJPIED MOBILE RADIO FACILITY. ,- � X X X X NEW T-MOBILE ANTENNA CABLES ROUTED FROM NEW EQUIPMENT ALONG NEW ICE BRIDGE UP I > I f EXISTING CONCEALMENT POLE TO NEW ANTENNAS x ITi /rf NEW T-MOBILE ICE BRIDGE. I s \ I NEW T-MOBILE EQUIPMENT AREA. REFER TO DETAIL 3/A-2 FOR I I SEE A-3 FOR MORE INFORMATION MORE INFORMATION d NEW T-MOBILE A R C H IT E C T S EQUIPMENT AREA f�l I 12.1 TECHNOLOGY DRIVE.SETAUKET,NY 11733 NEW T-MOBILE POWER AND TELCO 2 P.671.689.8450 1 F.631.689.8459 1-`Yf.Ia. I � I CONDUITS ROUTED FROM EXISTING 5 METER BANK/MESASPAN CABINET TOEa a ° NEW T-MOBILE EQUIPMENT. REFER TO / ----� DETAIL 4/A-2 FOR MORE INFORMATION i } d EXISTING FIRE DEPARTMENT ' = '3c` � V. EQUIPMENT AREA EXISTING ELECTRICAL PANEL .r? O+. SR�i i i" e\ Y, EXISTING 110' CONCEALMENT POLE NO, DATE EXISTING AT&T DIESEL GENERATOR 0 04/20/22 ISSUED FOR REVIEW m 1 -0-4/-2-5/2-2 REVISED PER RFDS 2 05/27/22 REVISED PER RFDS EXISTING AT&T EQUIPMENT AREA 3 08/3-3/22 ISSUED FOR FILING 4 04/11/23 REVISED PER COVMENTS X EXISTING COMPOUND FENCE I EXISTING CSC CABINET X X X X X EXISTING TRANSFORMER NOTES: NO CONSTRUCTION OR 81DOING IS TO PROCEED UNLESS COMPOUND PLAN PLANS INCLUDE THE STATEMENT IISSUED FOR (1�ENLARGED CONSTRUCTION'G THE DESCRIPTION COLUMN ASOYE. NEW T-MOBILE ELECTRIC METER NORTf 1 PRIOR TO BIDDING Oft CONSTRUCTION,CONTRACTOR E: 3/32"=1'-0" WITHIN EXISTING METER BANK MUST ALSO CONTACT WFC TO CONFIRM THEY ARE IN POSSESSION OF THE LATEST PLANS. 6" MATC-I EXISTING GRADE CONDITION KEY-AN. BACKFILL AT TRENCH SHALL BE AREA WORK COMPACTED IN '2" LIFTS TO 95% NOTE: DRY DENSITY -- PROVIDE A MINIMUM OF (2) COMPACTED SUBGRADE (COMPACT IN -_ SUPPORT POSTS PER TRAY SFCTION - 8" LIFTS TO 85% DRY DENSITY - J /i 6" WIDE METAL CORE UNDERGROUND -PROVIDE REBAR 24" O.C. EAC-I 3/4" CHAMFER / WARNING TAPE PRINTED WITH _ DIRECTION / �/ "CAUTION BURIED UTILITY LINES" NEW GRAVEL COVER N=W ICF BRIDGE KIT BY SITE / ��/ F TREATED WOOD POURED CONCRETE 3" # 2 \ \\/i\iy PLANKSOPAINTED RED. NUMBER OF PAD WITH HAJNCH AT PRO, PARI 1824-3 O /\ /\/ / �S PERIMETER NEW =LTER FABRIC 1 \\/\ / /\/ PLANKS AS RCC'D FOR WIDTH OF N /\ \/�\/`\/`\//\\//\ JqN TRENCH e -Mob _ le- ANTENNA CABLES ROUTED ALONG \T� //\\// ,p�� �� II=111 PVC CONDUIT, TYP. COORDINATE Ow 4 oA ICE BRIDGE =_ / v%0 —ILII Northeast LLC 1=III=1 GP I-II= II TYPE, SIZE AND NJMBER OF 3501 SUNRISE HIGHWAY,GREAT RIVER,NY U739 O O O O-III=1�1' o > I=II=1 — (Lill=11 CONDUITS WITH INFORMATION 11-III= = ip 11—I I —I-1I I==711=111 1 SHOWN ON ELECTRICAL DRAWINGS L I=[ EJ EEI I IL I LI I-1 I 0 111 Lio l —11= = IHJ-)II- AND WIT-i FLFCTRIC AND LAUEL PROV DE #4 RE ARS �� � �' "` Ill—fl 6" THICK LAYER OF NEW 8"X8'X1/2" STEEL PLATE Q IJ I'—I I. =III=III--LFIII—II—I—III— TELEPHONE UTILITY COMPANIES @ 12' O.C. EA. wA —III—f� 11=III- COMPACTED SAND OR z > 1=III II—III—III=11LI11 N� -JT—�1T---��I I _i ;I =1I 1 I11 _11=1 U-03-1'0-A =III-1 I-9 1=III Ehil_ GRAVEL BASE (4) 1/2" BO_IS IILI IILIIH'I�ICI WAST-ED SAND IN 6" _IFTS 7066 MAN RD QWY-2D COMOACT EXISTING =111 1=IIHII�I L L{1Ua,NY tW POJRED CONCRETE FOOTING, SET PIPE I 11E] LIIL=J1- UNDIS-URBED EARTH GRADE 10 95% DRY MOUNT AS INDICATED WITHN. —III=11=1111 DENSITY —I-TIL CONTRACTOR TO 'DE-WATER' TRENCH I— ENLARGED COMPOUND PLAN AS REQUIRED DURING INSTALLATION OF e &SITE DETAILS CONCRETE TO ENSURE PROPER NOTE: INSIALLAIION SIRLNGTH ////////////// 1. CONTRACTOR SHA I =NGAGF THE SFRVICFS OF AN UND=RGROUNJ UTR ITY I OCATING DATE. 04/13/22 COMPANY TO LOCATE ALL UNDERGROUND EQUIPMENT IN THE TRENCHING AREA TO AVOID ANY DAMAGE. PROJECT NO 22-1.5175 UNDISTURBED EARTH 2. HAND EXCAVA-E WITHIN 5' OF EXISTING UNDERGROUND U-IL'TIES (V.I.F.) MAINTAIN 18" MIN. DRAWN BY 6 CLEARANCE, OR AS DIRECTED BY TF-E VORC. CONTRACTCR TO MAKE ALL PVC JOINTS CHECKED BY: NM WATERTIG-IT. TEST PRIOR TO BACKFILLING. RFDS DATED: 05/27/22 CRAFT) DRAWING NO' CONCRETE PAD DETAILICE BRIDGE DETAIL 4 UTILITY TRENCH DETAIL A-2 2 SCALE: 1/2"=1'-0" 3 SCALE: 1/2"=1'-0" SCALE: 3/8"=1'-O" x x x x x x x x x x x x x 0 I NEW P1000 UNISTRUT SECURED TO NEW WEATHER CANOPY POSTS NEW T-MOBILE GPS UNIT MOUNTED I TO NEW ICE BRIDGE POST x NEW T-MOBILE H-FRAME. REFER TO DETAILS 1&2/A-6 FOR MORE INFORMATION NEW B160 & 6160 EQUIPMENT CABIN I > I NEW AUTOMATIC GENERATOR TRANSFER SWITCH MOUNTED TO NEW H-FRAME. REFER INSTALL (3) NEW QUAD DIPLEXERS 1, X TO DETAIL 2/A-10 FOR MORE INFORMATION A R C H I T E C T S MOUNTED TO NEW H-FRAME l..l j NEW T-MOBILE PPC CABINET MOUNTED TO r e 1.6898450 GY DRIVE. KET.NY 1117330 F.6311.6 9.8459 1 - INSTALL (3) NEW RADIO 4460, (3) NEW NEW H-FRAME. REFER TO DETAIL 2/A-6 R RADIO 4480 & (2) NEW RADIO 8863 I / __ FOR MORE INFORMATION MOUNTED TO NEW H-FRAME (STACKED) i "I x NEW T-MOBILE VZW AAV CABINET @.0 MOUNTED TO NEW H-FRAME. REFER TOi� =`4 ?T" NEW T-MOBILE LIGHT FIXTURE SECURED 1 I `� DETAIL 1/A-6 FOR MORE INFORMATION TO UNDERSIDE OF CANOPY DECK, OPERATED VIA TIMER SWITCH, TYP. REFER TO DETAIL 3/A-4 FOR MORE INFORMATIONri TY o *° /a NEW T-MOBILEX I EQUIPMENT AREA uo 20 22=REVISED I' a (10-0' X 22'-O") _ 0 04//25/ FOR REVIEW / ARFAI Z 1 05/25/22 REVISED PER RFDS (LEASE-- - 2 05/27/22 REVISED PER RFDS .0 -3 T8-/3o/221SSUED OR d I 1 4 04/1FFILING 1/23 REVISED PER COMMENTS X N I i d i 6" LINE OF NEW T-MOBILE WEATHER CANOPY ABOVE I I Xo+>_rEs a NEW T-MOBILE 48KW DIESEL GENERATOR ATOP NO CONSTRUCTION OR BIDDINGIS TO PROCEED UNLESS NEW CONCRETE PAD. REFER TO SHEET A-10 FOR PANS INCLUDE THE STATEMENT ISSUED FOR NEW T-MOBILE ICE BRIDGE. _ - EI MORE INFORMATION PRIOR TO BIDDING OR CONSTRUCTION,CONTRACTOR REFER TO DETAIL 3/A-2 FOR MORE INFORMATION MUST ALSO CONTACT WFC TO LACONFIRM THEY ARE IN / Q POSSESSION OF THE LATEST PLANS. 0 NEW T-MOBILE CONCRETE PAD. REFER TO DETAIL KE•�un. NEW T-MOBILE ANTENNA CABLES ROUTED d I X 2/A-2 FOR MORE INFORMATION APEA c.WoPK FROM NEW EQUIPMENT ALONG NEW ICE - BRIDGE UP EXISTING CONCEALMENT POLE a/ 10'-0" NEW T-MOBILE CONCRETE PAD V - - —_ TO NEW ANTENNAS _ / NEW T-MOBILE POWER AND TELCO CONDUITS ROUTED FROM EXISTING METER BANK/MESASPAN __ g X CABINET TO NEW T-MOBILE EQUIPMENT. REFER - / TO DETAIL 4/A-2 FOR MORE INFORMATION a � EXISTING COMPOUND FENCE d EXISTING =RE DEPARTMENT / EQUIPMENT AREA I X Mobile. a EXISTING ELECTRICAL PANEL Northeast LLC 3311 SUNRISE HwHWAY,GREAT RIVER,NY 11739 d I LAURE NSD m "3-110-A O FXISTING A&T 7056 MAN RD W-26) 0 G DIESEL GENERATOR LALREL.NY MM � T1le 0 0 EXISTING AT&T ENLARGED COMPOUND PLAN EQUIPMENT AREA 8 SITE DETAILS DATE' 04/19/22 EXISTING 110' CONCEALMENT 'OLE O EXISTING BUILDING DR5 O DRAWN AWNN'BY:Bx; (-,I CHECKED BY: NM R=DS DAieD: 06/27/22 mRAfT) DRAWING NO: ENLARGED EQUIPMENT PLAN A-3 1 (8) EXISTING 2"0 30LTS NQRTF- SCALE: 1/4"=l'-O" DENOTES SPAN OF 22 GA. 3" GALV. S-EEL ROOF DECK, TYPE NS AS 9'-2" CANOPY DECK MANUFACTURED BY UNITED X X - X X 4 1 SIL=_ DECK OR APPROVFD 'QUAI. 5,. 5" FASTEN DECK -0 STEE_ WI-H #12 S.S. OR GALV. SE SELF GRILLING TEK \ W6X15 B SCREWS Ca 8" O.C. MAX. ��. (� CANOPY SLOPE m .r + 3 1/8" PER FOOT iv I A R C H I T E C T S U0 ��4 I Y 121 TECHNOLOGY DRIVE.SETAUKET,NY 11737 U P.'631.689.8450 I F.631.689.8459 1­kai.. CO \ ?C W X �. CIL L) NEW CANOPY KNEE BRACE, TYP. I / y�1 REFER TO DETAIL 2"A3"/A-4 i < / X Ai�1, cq1 NEW LIGHT FIXTURES SECURED TO i KB X - �r UNDERSIDE OF CANOPY DECK OPERATED yW 15 r° VIA TIMER SWITCH, TYP. SEE DETAIL 3/A-4 FOR MORE INFORMATION y " D -y?J1Ss'.9C� NO 04/27/22 ISSUED FOR REVIEW 1 04/25/22 REVISED PER RFDS 2 05/27/22 REVISED PER RFDS 3"0 GALV. STEEL COLUMN WITH I 4 04/31/22 REVISE FOR FILING 4 04/11/23 REVISED PER CONVENTS 6"x6"x1/2" GALV. STEEL BASE AND CAP 2%"A2" PLATES, TYP. OF (6) ON CONCRETE PAD A-4 � X DASHED LINE REPRESENTS LINE OF NEW WEATHER CANOPY ABOVE / NOTM NO CONSTRUCTION OR BIDDING IS TO PROCEED UNLESS / PLANS INCLUDE THE STATEMENT-ISSUED FOR X CONSTRUCTION"IN THE DESCRIPTION COLUMN ABOVE. PRIOR TO BIDDING OR CONSTRUCTION,CONTRACTOR MUST ALSO CONTACT WFC TO CONFIRM THEY ARE IN i POSSESSION OF THE LATEST PLANS. O OA4En 0-•,v04[ O CANOPY FRAMING PLAN - 1 SCALE: 1/4"=1'-0" NORTH ALIGN TOP OF NEW WEATHER CANOPY LIG-/TING F XTURE SCHEDULENEW 3" 22 GA. TYPE 'B' GALV. ROOF DECK. r ®bl��® �I+ I TACK WELD TO NEW SUPPORTING STEEL I + MFG. & CAT. NO. FIX. WAII LAMP TYPE N WASP/ FINISH MOUNTING/HT. +J NEW GALV. STEEL W6x'5 I + Northeast LLC RAB LIGHTING 39 LED 1 BRONZE SURFACE MTD. L3x3xl/4" BRACING AT UNDERSIDE OF DECK 3510SUNMEEUGHWAY,GREAT nEvrmlln9 FFLED39 NEW 6"x6"xl/2" GALV. ST==_ PLAT=+ ry NEW VERIZCN W RELESS LI1LFa SFCLRFD TO NFW W6x15 WITH (a) 1� EQUIPMENT PAD NSD 1/4 3/4"0 A325 BOLTS, TYP. 1'-s" LI-03-110-A NEW 30 GALV. STEEL COLUMN WELDED - TO NEW 1/2" THICK BASE PLATE NEW 30 GALV. STEEL 7066 MAN f�QiY-29 1" COLUMN WELDED 10 NEW LAUD NY 11952 r aIo NEW 6"x6"xl/2" GAIV. ST=F PIATF 16- G/ 1/2" THICK BASE PLATE SECLRED TO NEW CONC. DAD WIT-i L3" X 3" X 5/16' e. DO (4) 1/2"0 HR TI KWIK BOLT 11 LV. STL. ANGLE 1/4 NEW 6"x6"x 1/2' GALV. CANOPY FRAMING PLAN EXPANSION ANCHORS (3-'/2" MIN. STEEL LATE SECURED TO AND TYPICAL DETAILS 1/4 EMBED.), TMP. OF (4) PLATES uNEW CONC. PAD WITH (4) i (1) 3/4"0 A325 1/2"0 FIL I KWIK BOLT I DATE 04/13/22 NEW VERIZCN WIRELESS BOLT. TYP. EXDANSION ANCHORS "RaEc•No: 22-175 EQUIPMENT PAD 3/8" TAB WELDED (3-1/2" MIN. EMBED.), ORAW45� C! TO POST/BEAM 1" TYP. OF (4) PLA-ES CHECKED 3�. RN CEEB D LIGHT FIXTURE VERTICAL SECTION SAT TYP.KNEE BRACE'A3' PLAN AT CANOPY POST'" DRAW.NNIG NC' avz7rrz m 4 3 LIGHT FIXTURE DETAIL 2 CANOPY POSTS + FRAMING DETAILS A-4 SCALE: N.T.S. 5 123'-0" A.G.L. 1.0. EXISTING F.D. WHIP ANTENNA A R C H I T E C T S FIRE DEPARTMENT WHIP ANTENNAS 110'-0" A.G.L. 12.1 TECHNOLOGY DRIVE.SETAL:KET,NY 11733 T.O. EXISTING CONCEALMENT PCLE BY ELITE TOWERS P.631.689.84501 F.631.689.84591—El,i.— I -- I 110C' CONCEALMENT PO-E 100-0 A.G.L� �g y f �4 L3f �s+,,'•; vLTa �- T.O. EXIST NG CAVIS7ER m3B rr v^✓"" " ��y I t 90' A. -0" G.L.o -J- I T.O. EXIST NG CANISTER 180'-0" AG.L•h -i T.0 UPPER T-MOBILE CANISTER ' v0. DACE iSS:ON 75'-0" A.G.L.o 0 04/20/22 ISSUED FOR REVIEW (6) NEW T-MOBILE ANTENNAS AND (3) NEW c UPPER T-MOBILE CANISTER 1 04/25/22.REVISED PER REDS SMART BIAS TEES INSTALLED WITHIN EXISTING 2 05/27/22:REVISED PER RFDS CONCEALMENT POLE. REFER TO SHEET A-8 70'-0" A.G.L.,` 4 04/31/22:REVISE FOR FILING FOR MORE INFORMATION T.O. LOWER T-MOBILE CANISTER a Da/11/z3 REVISED PER COU VENTS I 65'-0" A.G.L. c LOWER T-MOBILE CANISTER IO 60'-0" A.G.L. (24) PROPOSED T-MOBILE 7/8" COAX I T.O. EXISTING BASE POLE CABLES ROUTED FROM NEW T-MOBILENOTES• I EQUIPMENT ALONG NEW T-MOBILE ICE BRIDGE NO CONSTRUCTION OR BIDDING IS TO PROCEED UNLESS UP TO NEW T-MOBILE ANTENNAS PLANS INCLUDE THE STATEMENT'ISSUED FOR CONSTRUCTION'IN THE DESCRIPTION COLUMN ABOVE- , PRIOR TO BIDDING OR CONSTRUCTION,CONTRACTOR MUST ALSO CONTACT WFC TO CONFIRM THEY ARE IN NEW T-MOBILE ICE BRIDGE. REFER TO POSSESSION OF THE LATEST PLANS. DETAIL 3/A-2 FOR MORE INFORMATION AREA OP WORK NEW T-MOBE WEATHER TO SHEET AI 4 FOR MORE IINOFORMATIONR NEW T-MOBILE EQUIPMENT AREA. SEE A-3 FOR MORE INFORMATION I NEW T-MOBILE ELECTRIC METER WITHIN EXISTING METER BANK T o® ® L ®bile EXISTING TRANSFORMER Northeast LLC WR EUNWE®cHWAY,OQPAT RIVER,NY 117" LAME T.O. NEW T-MOBILE WEATHER CANOPY10 NSD L-03_1 o o i 7066 MAN 11D W-28 0 LAUB,NY tM i) D' TRLE- J GRAD= WEST ELEVATION I I DATE: 04/13/22 =ROJECI NO. 22-15175 DRAWN BY CA CHECKED BY: N.1 RFDS DATED. 06/27/12 BDRAFfI DRAWING NO: 1 WEST ELEVATION A-5 SCALE: 1/16"=l'-D" ENCLOSURE: -MFG.: ERICSSON -PART NO.: 6160 NOTE: MECHANICAL INFO (1) CABINET TO BE VERIZON AAV -DMENSIONS (HxWxD): 63"x26"x3/" OUTDOOR CABINET SJPPLIED BY T-MOBLE, AND INSTALLED BY NEW CANOPY POST ENCLOSURE WEIGHT: 295 LBS CONTRACTOR. REFER 10 CABINET -BATTERY MANUFACTURER SPECI=ICATIO14S AND NEW VERTICAL P1000 TTO ALWE WEIGHT: WEIGHT:88388DS (3 STRINGS) 6S DRAWINGS FOR MORE INFORMATION. UNISTRUT MEMBER, LENGTH SPECIFICATIONS FOR PURCELL SSC: TO BE VERIFIED IN FIELD 24" TALL x 24" WIDE x 16.67" DEEP BY CONTRACTOR (25.24" DEEP WITH HEAT EXCHANGER) WEIGHT: 64t LBS CABINET ONLY, 100 LBS WITH 4 BATTERIES // 1z1TECHNOLO VE.SETAUKET,NY 11731 ( ) • ! \_i O O �l P.631.689.8450 O �9�8�59 I w.w.Wfcaia.cnm Y ORI NEW VZW AAV b ,mid o NEW HORIZONTAL P1000 s v 5� UNISTRUT MEMBER, LENGTH $' TO BE VERIFIED IN FIELD BY CONTRACTOR I ._ .` _ r, § i _ nn _ fir' S El t � NEW CONCRETE SLAB a� (SEE DETAIL 2/A-2 FOR ADDITIONAL INFORMATION) Al IA a g '` .. p0 EXITING GRADE a .. - - - DATE ISSUED F _oO' O Oo' o0 ♦6 / \0 04/20/22 ISSUED FOR REVIEW \ \/\/\/\/ -• 1 04/25/22 REVISED PER RFDS :. �. �, 0 � .O. ,0,,Q,. 2 05/27/22 REVISED PER RFDS ! _ 3 09/30/22 ISSUED FOR FILING - - - - - 4 04/11/23 REVISED PER COVMENTS TOP FRONT SIDE BACK TYPICAL VZW AAV DETAIL 3 TYPICAL B160 BATTERY CABINET DETAIL SCALE: N.T.S. NOTES- NO O S•NO CONSTRUCTION OR BIDDING IS TO PROCEED UNLESS 12CVAG GFI PIANS INCLUDE THE STATEMENT-ISSUED FOR 2'-0' ENCLOSURE: CONSTRUCTION'IN THE DESCRIPTION COLUMN ABOVE. PROTECTED PRIOR TO BIDDING OR CONSTRUCTION,CONTRACTOR CONVEN ENCS -MFG.: CRICSSON MUST ALSO CONTACT WFC TO CONFIRM THEY ARE IN OUTLET PART NO.: 6160 POSSESSION OF THE LATEST PLANS. NEW CANOPY POST MEC-1ANICAL NFO <E. "' - AxeA o=wGe< - -DIMENSIONS (HxWxD): 63"x26"x34" NEW HORIZONTAL P1000 -ENCLOSURE WEIGHI: 414 LBS UNISTRUT MEMBER, LENGTH -EQUIPMENT WEIGHT: 285 LBS -_ TO BE VERIFIED IN FIELD ! 200 AMP -TCTAL WEIGHT: 699 LBS BY CONTRACTOR L GENERATOR NLE- - 20C AMP - GENERATOR NLET i i SCRLEN_J !OL'VFRS GJ FOR TELCO 0 0 .0..0 0 .o 0,o' 120VAC GFI PROTECTFD COMDARTIVENT CONVENIENCE CJTLET ( PLAN PPC BOX SIM o Wa�a 0 0 ®1 SCREENED LOJVERS FOR g 200 AMP Northeast LLC TELCO COMDARTMENTGENERATOR NY SUNRISE HLGUWAY,GREAT RIVER, Y 11739 INET ATTACH ENTIRE '! 12CVAC CF! O '' O LAUREL UNIS-RUT ASSEMBLY TO PROTEC-ED NEW 3-1/2"0 PIDE ° CONVENIENCE � L� '� 3-� -A NEW CONCRETE SLAB OUTLET 0'. SEE DETAIL 2/A-2 FOR UTII]ZING 3/8" MAIN RD Y MM ADDITIONAL INFORMATION) i ' U-BO_TS AND NUTS NEW 'MAR O LAIC NY 71952 AND WASHFRS. (TYP.) ° G8 SERIES O rLe EXITING GRADE ' AIIACH UNISIRUI IC ° r. OVER/UNDER EQUIPMENT CABINET DETAILS EACH OTHER USING O ° POWER O O OO O O L -ION3/8"0 SPRING 60FROTFC ITHUT(P2380-2) NCABINET (-PC). O O DATE. 04/13/22 AND WASHE _4 O O. C O O O O OO122-16175 ME D wN9!.. ci NEW UNTSTRUT FRA c EC TO BE 'U'-BOLTED TO I TOP FRONT SIDE BACK AT RFDS DATED. tae 05/27/22 Ql7gFTI NEW 3-1/2"0 PIP= DRAWINGNO. TYPICAL PPC CABINET DETAIL HIGH SCALE: BE 4 TYPICAL ENCLOSURE 6160 DETAIL A-6 2 SCALE: N_T.S. DOPED GALVANIZED. SCALE: 1/2"=V-0° l RADIO 4460 RADIO 4480 RADIO 8863 -MFG.: ERICSSON -MFG.: ERICSSON -MFG.: =RICSSON -PRODUCT NO.: KRC 161 912/3 -'RODUCT NO.: KRC 161 922/1 PRCDJCT NO.: B41 FOR NR AND LTE DIMENSIONS: (HxWxD) 17.0"X15.1"X11.9° DIMENSICNS: (HxWxD) 21.8"X15.7"X7.5" DIMENSIONS: (HxWxD) 18.8"X14.8"X6.1" =' WE GHT/ VOLJME: 1 C9.0 LBS/ 13 GAL. W=GH_/ VOLUME: 93.0 LBS WEIGHT/ VOLUME: 53.1 LBS/ 13 GAL. FREQUENCY BANDS: 3GPP FDD 82/25 & 366 FREQUENCY BANDS: DUAL BAND, WCDMA, LTE AND NR =REQUENCY BANDS: B41 FOR NR AND LTE 13W: UP TO 65MFz IN 82/25, UP TO 9OMHz IN B66 13W: 2X 2.5/ 4.9/ 9.8/ 10.1 GBPS CPR] BW: UP TO 65MHz IN 82/25, UP TO 90MHz IN B66 NORMAL OPERATING TEMP.: -40 - +55C NORMAL OPERAIING IEMP.: -40 - +55'C NORMAL OmERATING TEMP.: -40 - +55•C OUTPJT POWER: UP TO 4x8OW IN B2/25, UP TO OUTPUT POWER: UP TO 4x6OW PER BAND, UP TO OUTPUT POWER: UP TO 4%BOW IN 82/25, UP TO A R C H I T E C T S 4x8OW IN B66. UP TO '40W IN TOTAL 4x8OW TOTAL W/O =AN. U' TO 4x80W TOTA_ W/ FAN 4x8OW IN B66. UP TO 140W IN TOTAL 124 TECIINOLOOY DRIVE,SETAL:KET,NY 11733 P.631.689.8450 I F.631.689.8459 1­fcai.. 5 S11 v� ap[�ti �r'. -F'= Fes' �1` AM[UP Fmfl PH , C:1 } Q� OOO0 � 60 411 - BOTTOM BACK SIDE BOTTOM BACK SIDE BOTTOM BACK SIDE NO. DAI 0 04/20/22 ISSUED FOR REVIEW 1 04/25/22 REVISED PER RFDS 2 05/27/22 REVISED PER RFDS 308/30/22,ISSUED FOR FILING TYPICAL RADIO 4460 DETAIL TYPICAL RADIO 4480 DETAIL TYPICAL RADIO 8863 DETAIL 4 04/11/23 REVISED PER COMVENTS 1 SCALE: N.T.S_ 2 SCALE: N.T.S. 3 SCALE: N.T.S. MANUFACTURER: MICRODATA MODEL: ;MI-54844 QUAD DIPLEXER NOTES: DIMENSIONS (SINGLE UNIT):'9.41" x 4.33" x 1.91 (H x W x D) NO CONSTRUCTION OR BIDDING IS TO PROCEED UNLESS WEIGHT (SINGLE UNIT): !5.73 LBS 1 PLANS INCLUDE THE STATEMENT-ISSUED FOR CONSTRUCTION'IN THE DESCRIPTION COLUMN ABOVE. PRIOR TO BIDDING OR CONSTRUCTION,CONTRACTOR MUST ALSO CONTACT WFC TO CONFIRM THEY ARE IN POSSESSION OF THE LATEST PLANS. NEW CANOPY POST GROUND 2.76 <El TOP AREA O=wORi NEW VERTICAL P1000 UNISTRUT MEMBER, LENGTH N - TO BE VERIFIED IN FIELD BY CONTRACTOR '- 1 7.24 5.67" i � NEW RADIO III o I � NEW RADIO I j BO TQM I i \ •j —� 4.13" GROUND NEW HORIZONTAL P1000 e UNISTRUT MEMBER, LENGTH TO BE VERIFIED IN FIELD i T..Mobile- �e® - BY CONTRACTOR � 1 0 3.5" Northeast LLC O O . RIB 3500 RUNE HIGHWAY,GREAT RIVER,NY IIT39 EL .47"J CONN 4.3-10 (F) LAIJ NEW CONCRETE SLAB (2 OUT / 4 1N) NSD� (SEE DETAIL 2/A-2 FOR 7055 AIN RD IN-� 0-A ADDITIONAL INFORMATION) 1.95" 00 OO O' LA1Ri,NY 11952 IIiLE: EXISTING GRADE '` \ \ \ '\/\ \ .47" EQUIPMENT DETAILS � DATE 9.41" CONNECTORS:4.3-10 (F) x 6 LONG 'ROJ 04/13/22 1 =eaEcr NO' 72-15175 NECK (SINGLE T141N1 DRAWN 9V tr',I 11/a/21 REV 0 �UP—LOADED SKU# 34546 — MI-54844 CI ECKED a•: NM QUAD DIPLEXER 1 RFDS DATED OG127/22 CRAFT") 8.5-x II-SCALE N.T.S.1 11-a 17-SCALE N.T.S. DRAWING NO. 4 TYPICAL RADIO MOUNTING DETAIL TYPICAL OUAD DIPLEXER DETAIL A-7 SCALE: N.T.S_ 5 SCALE: N.T.S. 7 1.811' 7.126" ANTENNA SeCTOR -PART• NO.: FVVo65B-R3 3 C p I MECHANICAL INFO 340 �Q -WEIGHT (ANTENNA): 43.872 LBS. WEIGHT (HARDWARE: 8.598 LBS. DIMENSIONS (IIXWXD): 71.969"01.81'"x7.126" MAX. WIND VELOCIT": 149.75 MPH A R C H I T E C T S —HARDWARE MATERIAL: GALVANIZED STEEL pl 12.1 TECHNOLOGY DRIVE,SETACKET,NY 11733 EXISTING 12" SC -CONNECTOR TYRE: 4.3-10 FEMALE BOT-OM, 4 HIGH 6D PPE MAST - P.631.689.8450 I F.671.689_8459 I,ww.,vfaia.mm BAND, 2 LOW BAND In -COLCR: LIGHT GRAY \ -". n` „sem, '.„r�•I lrrr+, 36" O.D. MULTI PART, r7 O + a s3 MULTI-SICED CONCEALMENo iL, RADOME, TYP. OF (6) '10 cd (3) NEW FW-658-R3 ANTENNAS TO BE INSTALLED As N BOIIOM BACK SIDE 1, el NO. DAIE SJdMI$SION 2 TYPICAL FW-65B-R3 ANTENNA DETAIL D 04/25/22 ISSUED FOR REVIEW 1 04/25/22;REVISED PER REDS U11 o SCALE: 1/2"=V-0"•-O" 2 05/27/22 REVISED PER RFDS 3 08/30/22 ISSUED FOR FILING PLAN ® TOP CANISTER (75') 4 04/11/23;REVISED PER CONVENTS ATSBT-TOP-MF-4G OTE: INSTALL (3)3 NEW SMART BIAS TEES. Top Smart Bias Tee (NOT SHOWN FOR CLARITY) __p 'y' "'' 17�a • Redu:e3 Wbk drr,,seta lease xs by elm nat ng the need for AISG home ru,casles NOTES: -•+T; * ''-' • AISC 1 1 enc 7 D—.1fiar NO CONSTRUCTION OR BIDDING IS 10 PROCEED UNLESS • 0„:trt nl it-30 Vdr _ PLANS INCLUDE THE STATEMENT'ISSUED FOR • FVee'hetpla 1,,13E w'-a��ws CONSTRUCTION'IN THE DESCRIPTION COLUMN ABOVE. : Irn3rt.e 3-die nmics srlphry 3rd ensue rror,,nsaltat cr PRIOR TO BIDDING OR CONSTRUCTION,CONTRACTOR _n--c IGhmng hret[cilCn:I g•c.,,d ng,tul r—did.,real surge forntmlon MUST ALSO CONTACT WFC TO CONFIRM THEY ARE IN :-16 U N lege e loaner SAN') POSSESSION OF THE LATEST PLANS. SECTOR P 7-16 D N-L'lc,»nnrctca'3T 31 _ �`• � AREA O.W c21 340 GAO ProduLp Llassilication _- �0 Product Type I>Er:iaS leE EXISTING 12” SC General SpecificaUonS + a 160 P PE MAST AISG Input Connector Sym DIN I"cle _ Antenna Interface /.16 DIN Fenae Ardent Interface Signal R' &'3 ---<ai =- BTS hderf— /-16 I:IN Ma e 36" O.D. MULTI-PART, M p HITS Interface Signal ASOdata I R= I d< MULTI-SIDED CONCEALMEN- CYLINDER, TYP. OF (5) M h Color sow EU inn CF GroundingT®8 ® 11 e- � O Grounding Lag Thread Size M5 '1O Smart Bias Tee Type ,5-....;Is- Northeast LLC (3) NEW FW-65B-R3 Will SUNME HIGHWAY,GREAT x1VEa,NY 117M ANTENNAS TO BE INSTALLED >7, Dimensions � Height 14:if,r..:mm I , LAUREL Width 94 m•n 37C,, /� NSD Depth V:v- 1969., U-03-MTA Electrical Specifications 7056 MAN RD(NY-29 3rd Order lMD 56 CLU: L44a 'NY 11 62 3rd Order IMD Test Method 1-143 cHm cernm TITLE' T`3 Insertion Loss,rypMal C'cR ANTENNA INFORMATION c &ANTENNA MOUNTING DETAILS 0 Electmmagnetie Compatibility(EMC) CFR 47 P+c:-5 S.6-1 3,Class e I EN 55i,22 CJass 0 1 IC EW-3 1,",z:::,N PLAN ® BOTTOM CANISTER (65•) �3 DA!E. 04r13/22 03 -Rc:=c No 22-151/5 DRAWN 51: C.I •MMSCOPF CiEC<ED Br: Mv1 RPD$DATED 05/27!12 mRAFTI DRAWING NO ENLARGED ANTENNA PLANS N0�—H 3 TYPICAL BIAS TEE DETAIL (AT ANTENNAS) A-8 1 SCALE: 1"=1'-0" SCALE:N.T.S ANTENNA SCHEDULE CABLE SCHEDULE NOTE: GENERAL NOTES SECTOR 1HEIGHT MDT TX-RX MANUF-MODEL# CABLE LENGTH DIA. LABEL/NOTE ALL EXISTING AND NEW ANTENNAS,EQUIPMENT AND 1-ALL INDICATIONS OF NORTH ARE FOR REFERENCE ONLY.CONTRACTOR TO VERIFY IN TX/RX TX/RX +/-120-0 7/8" 1 RED ASSOCIATED APPURTENANCES(IE:CABLE TRAYS,ICE FIELD TRUE NORTH PRIOR TO SECTOR ANTENNA INSTALLATION. TX/RXTX/RX +/-120'-0" 7/8" 2 RED BRIDGES,ETC.)MUST BE GROUNDED IN ACCORDANCE A 90° 75' 0° NEW WITH T-MOBILE STANDARDS. 2-CABLE LENGTHS LISTED ARE APPROXIMATIONS PROVIDED BY OWNER AND ARE NOT TX/RX COMMSCOPE TX/RX +/-120'-0" 7/8" 3 RED INTENDED TO BE USED FOR ORDERING CABLE.ALL CABLE LENGTHS MUST BE VERIFIED IN TX/RX FVV-65B-R3 TX/RX +/_120'-0" 7/8" 4 RED FIELD. TX/RX TX/RX +1-120'-0" 7/8" 5 RED MIN.CABLE BENDING RADIUS TX/RX TX/RX +!-120'-0" 7/8" 6 RED 3-THE CONTRACTOR SHALL INSTALL BRASS TAGS(SUPPLIED BY T-MOBILE)AT EACH END CABLE RADIUS WWT.PM FT. O.D. OF ALL ANTENNA CABLES DENOTING THE NUMBER OF TAPE MARKING BANDS AND COLOR TX/RX TX/RX +!-120'-0" 7/8" _ 1 WHITE OF TAPE MARKING BANDS. TX/RX NEW TX/RX */ 120'-0° 7/8" 2 WHITE 112°CABLE SUPERFLEX(FSJ-050 1/4" 0.14 LBS 0.52" B 210° 75' 0° +/_120.0^ 718" 3 WHITE 1/2"CABLE(LDF 4-SOB) 5" 0.15 LBS. 0.63" 4-ANTENNA CABLES WILL BE COLOR CODED AT THE ANTENNA,FILTER INJECTION A R C H I T E C T 5 Z' TX/RX COMMSCOPE TX/RX CABINET,JUMPER CONNECTIONS AND THE BTS CABINET. Q TX/RX FW-65B-R3 TX/RX ___+1-120'-0" 7/8" 4 WHITE 12 1 TECHNOLOGY DRIVE,SETAIKET,NY 11717 7/8°CABLE(LDF-0-50A) 10" 0.33 LBS. 1.09" F.631.689.8450 I F.671x6§9;8459 I V TX/RX TX/RX */ 120'-0" 7/8" 5 WHITE 5-THE CONTRACTOR SHALL INSTALL DRIP LOOPS ON ALL ANTENNA AND JUMPER O +/_120'-p" 6 WHITE 1 114"CABLE(LDF-&50A) 15" 0.63 LBS. 1.55" TX/RX TX/RX 7/8" CABLES. a TX/RX TX/RX +/-120'-0" 7/8" 1 BLUE 1 518"CABLE LDF-7-50A 20" 0.82 LBS. 1.98" ~ TX/RX NEW TX/RX *! 120'-0" 7/g" 2 BLUE 6-THE CONTRACTOR SHALL INSTALL ADDITIONAL CABLE SUPPORTS AS NEEDED TO �: �1 C 340° 75' 0° Ar.,^ s''e"-:C. +/.120'-0" 7)8" 3 BLUE MAINTAIN A MINIMUM SPACING OF 3'-0"ON CENTER. I;T, COMMSCOPE Twp CABLE SIZES/LENGTHS FVV-65B-R3 TX/RX +/-120'-0" 7/8" 4 BLUE UNLESS OTHERWISE NOTED: 7-THE CONTRACTOR WILL RECORD THE LOCATION AND SERIAL NUMBERS OF ALL fK� P P:+-120,_0" „ 5BLUE FOR SECTORS 0'-100'USE 7/8"0 CABLE ANTENNAS,ANTENNA CONTROLLER MOTORS,AND THEIR CORRESPONDING INSTALLED TX/RX */'120'-0" 7/8" 6 BLUE FOR SECTORS 101'-150'USE 1-1/4"0 CABLE LOCATION AT THE TIME OF CONSTRUCTION. TX/RX TX/RX +/_110'-0" 7/8" 1 RED FOR SECTORS 151'&ABOVE USE 1-5/8"0 CABLE �' T TX/RX NEW TX/RX +!-110'-0" 7/8" 2 RED 8-ALL ANDREWS MOTORS ARE GENDER SPECIFIC,AND WILL BE WIRED STARTING WITH ` V- A 90° 65' 0° +/_ ' " 7/g" 3 RED THE MALE END OF THE CABLE AT THE BTS AND CONTINUE ALONG THE RUN FOLLOWING TX/RX COMMSCOPE TX/RX 110-0THE'FEMALE UP RULE'. TX/RX FVV-65B-R3 TX/RX +/-110'-0" 718" 4 RED TXlRX TX/RX +1-110'-0' 7)8" 5 RED /7 g, d TX/RX TX/RX +/-110,_0.. 7/8" 6 RED (f) TX/RX TX/RX +/-110'-0" 7/8" 1 WHITE NO. DATE SUBMISSION ZQ TX/RX TX/RX */-110'-0" 7/g•• 2 WHITE B 210° 65' 0° NEW +/-110'-0" 3 WHITE D 04/25/22 REVISE FOR REVIEW V TX/RX COMMSCOPE TX/RX 718" t 54/25/22 REVISED PER RFDS TX/RX FW-65B—R3 TX/RX +/—110'-0" 7/8" 4 WHITE 2 05/27/22 REVISED PER RFDS TX/RX TX/RX */—110'-0" 7/8•• 5 WHITE 3 08/30/22 ISSUED FOR FILING TX/RX TX/RX *!— —0" 7/8" 6 WHITE 4 04/11/23 REVISED PER COMMENTS 110' TXIRX TX/RX +1-110--0-ITI- 1 BLUE mTX/RX TX/RX +1-110'-0" 2 BLUE C 340° 65' 0° TX/RX NEW TX/RX +/-110'-0" 3 BLUE COMMSCOPE TX/RX FVV-65B-R3 TX/RX */-110'-0" 4 BLUE TXIRX +/-110'-0" 5 BLUE TX/RX TX/RX 110'-0" 6 BLUE NOTES: NO CONSTRUCTION OR BIDDING IS TO PROCEED UNLESS PLANS INCLUDE THE STATEMENT"ISSUED FOR CONSTRUCTION"IN THE DESCRIPTION COLUMN ABOVE. PRIOR TO BIDDING OR CONSTRUCTION,CONTRACTOR MUST ALSO CONTACT WFC TO CONFIRM THEY ARE IN POSSESSION'OF THE LATEST PLANS. <cY a,Au: AREA OF WORK v I°J. ®bile- Northeast LLC MOD SUNRISE HIGH WAY,GREAT RIVER,N�Yp137" AL NSD U-03A10-A 7055 MM FD air-20 Ili Kr MM •ITLE' ANTENNA INFORMATION DA:^ 04/13/22 PRO,ECI NO: 22-15175 DRAWN BY CJ CHECKED BY NM RFOS DATED: 06/27/22 IDRAFTI DRAWING NO. A-9 • �(Qp� GENERAL RD048 ' RATED POWER 48kW, 31.25kVA, 60Hz DIMENSIONS (LxWxH) 103.4"x35"x90" 4e WEIGHT 2915LBS. FI1FI. CONSLMPTION 2.15 GALLONS/HOUR 8'-7 3/8" (50% LOAD) 96 HRS 3.06 GALLONS/HOUR (75% LOAD) 67 HRS �- 3.98 GALLONS/HOUR (100% -DAD) 52 HRS ❑ I FUEL TYPE ULTRA LOW SULFUR DIESEL O, N TOTAL CAPACITY 240 GALLONS A R C H I T E C T S USABLE CAPACITY 229 GALLONS 12.1 TECIINOLOCY DRIVE.SETAL;KET,NY 11737 ACOUSTICS 65 dB AT.23 FEET P.631.689.84501 F.631.689.84591­15c.i..— COOLING AIR FLOW 2824 CLBIC FT/MINLTE / o o EXHAUST TEMP. 1120'F, 604.4'C VOLTAGE REGULAT ON +/- 1.0% SAFETY 48 HR MIN. RUN TIME UL 142 LISTED TYPICAL vw.' LOCKABLE FUEL CAP DC GENERATOR NO ATS REQUIRED FOR CC GENERATOR i l?'e„ RATED ENG,NE SPE 1,800 RPM OPERATIONS ® 80. PROPOSED #2 AWG BARE TINNED SOJND COPPER GROUND WIRE FROM p PROPOSED GENERATOR o DAieM y - t0 C GROUND TO EXISTING GROUND 0 04/27/22,ISSUED FOR REVIEW I I ^ NO AC POWER MODIFICATIONS IN RING. PROVIDE 2-HOLE LUG 0a zs/22 REVISED PER REDS o SCOPE OF WORK D CONNECTION TO GEN z 05/27/22 REVISED PER RFDS AN-) CADWFI D CONNECTION TO 3 08/37/22 ISSUED FOR FILING EXISTING GROUND RING (TYP.) a 04/11/23 REVISED PER COMMENTS PROPOSED I" SCH. 80 PVC CONDUIT WI-H CAT6 CABLE FROM PROPOSED DC ' s EXISTING -20/240V 200 GENERA-OR TO EXISTING SWITCH 2'-11" AMP AC PANEL. NO WORK FOR DAA CIRCUIT (TYP.) 8'-7 3/8- " / ON AG SERVICE DURING NO CONSTRUCTION OR BIDDING IS 10 PROCEED UNLESS ti LEXISTING CONCRETE SLAB THIS SCOPE OF WORK S I. 80 PVC PLANS INCLUDE THE STATEMENT"ISSUED FOR EXISTING AC PROPOSED 2" CI � CONSTRUCTION"IN THE DESCRIPTION COLUMN ABOVE. SECURE NEW GENERATOR TO PANEL CONDUIT WI-H (2) 2/0 AWC TYPE PRIOR TO BIDDING OR CONSTRUCTION,CONTRACTOR GENERATOR DETAIL / / CONTROLLER XH-]W CONDUC ORS FROM "UST ALSO CONTACT WFC TO CONFIRM THEY ARE IN EXISTING CONCRETE SLAB W 1 2" POSSESSION OF THE LATEST PUNS. 1 SCALE: 1/4"=1'-0" S/S RODS SET IN HILT] HIT HY-150, PROPOSED GENERATOR (TYP.) ` „AN MIN. 3-1/2" EMBEDMENT (TYP.) AREA OF•NORK PDUO/ B_U --- DAISY CF-ANCE (2) 2/0 AWC CONDUCTORS TO EXISTING NOTE (i) AUTOMATIC GENERATOR TRANSFER NEW CANOPY POST I PSU/REC�. EXISTING BA ERY CONNECTION A BFU SWITCI-. SWITCH SUPPLIED BY T-MOBILE EQUIPMENT W TH PROPOSED REMA SR 350 AND INSTALLED BY CONTRACTOR. REFER NEW VERTICAL P1000 PCUAC06 CABINET WVS-9H CONNFCTOR ASSFMBI Y TO MANUFACTURER SPECIFICATIONS AND UNISTRUT MEMBER, LENGTH DRAWINGS FOR MORE INFORMATION. TO BE VERIFIED IN FIELD h HEIGHT RANGE: 36"-48" BY CONTRACTOR I WIDTH RANGE: 24"-30" , DEPTH RANGE: 10"-14.8" I EXISTING 50 AMS/2P BREAKER T..Mobile- NEW AUTOMATIC GENERATOR TRANSFER SWITCH Northeast LLC I 3l8G SUNRISE HIGHWAY,GRRAT RIVM NY 11739 NEW HORIZONTAL P1000 1 LALRE- 1 UE FIELNSDD T0BE VERIFIEDN LH33-11O-A BY CONTRACTOR7055 MAIN RD INY-215)— ( EMIL NY 119512 iii'',E' -, GENERATOR.TRANSFER SWITCH DETAIL NEW CONCRETE SLAB &ELECTRICAL RISER DIAGRAM (SEE DETAIL 2/A-2 FOR DATE 04/19/22 ADDITIONAL INFORMATION) " PROJECT NO. 22-15fl5 DRAWN Bim: ci EXISTING GRADE '" CHECKED By NM RFDS DATED. 06/27/22 CRAFT) DRAWIIJG vc ( 2)AAUT0MA_nQ GENERATOR TRANSFER SWITCH DETAIL ELCTRICAL RISER DIAGRAM A-] 0 SCALE: N.T.S. 3 SCALE: N.T.S.