Loading...
HomeMy WebLinkAbout48906-Z o�oS0Fat,fcoG� Town of Southold 7/12/2023 y�t,33 P.O.Box 1179 "o y� 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44265 Date: 7/12/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 51750 Route 25, Southold SCTM#: 473889 Sec/Block/Lot: 63.-6-4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/31/2023 pursuant to which Building Permit No. 48906 dated 2/14/2023 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on existing accessory garage as applied for. The certificate is issued to Umana,Jose of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48906 4/11/2023 PLUMBERS CERTIFICATION DATED A(athofidd SignatiA �SUFFot,r .. TOWN OF SOUTHOLD BUILDING DEPARTMENT 1 TOWN CLERK'S OFFICE Wo . �= SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48906 Date: 2/14/2023 Permission is hereby granted to: Umana, Jose 51750 Route 25 Southold, NY 11971 To: Install roof mount solar to existing accessory garage of single family dwelling as applied for, with HPC approval. Disconnects must be located on the exterior, labeled and readily accessible. At premises located at: 51750 Route 25, Southold SCTM #473889 Sec/Block/Lot# 63.-6-4 Pursuant to application dated 1/31/2023 and approved by the Building Inspector. To expire on 8/15/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector oF so�ryQl 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(a-town.southold.ny.us Southold,NY 11971-0959 QIyCOUm,��\ BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Jose Umana Address: 51750 Route 25 City:Southold st: NY zip: 11971 Building Permit#: 48906 Section: 63 Block: 6 Lot: 4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Peconic Bay Electric Corp License No: 46360ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 7.04kW Roof Mounted PV Solar Energy System w/ (22) Phono PS320MH Modules, IQ Combiner, AC Disconnect Notes: Solar i Inspector Signature: r Date: April 11, 2023 S.Devlin-Cert Electrical Compliance Form OE SOUTyOIo # # TOWN OF SOUTHOLD BUILDING DEPT. b courm, 631-765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL Golo-e-_- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: I C DATE - - INSPECTOR SOUTyO ¢Q V& S-r� J CJ # # `N �/ BUILDING DEPT. N , TOWN OF SOUTHOLD -� .. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION /[ ]_ PRE C/O [ ] RENTAL REMARKS:OL^cr Jan 44 nke-A Wowl-ef id 4 7;eVAl-e'- � - DATE INSPECTOR �� FIELD INSPECTION REPORT DATE COMMENTS �d 04 FOUNDATION (1ST) p y G—zlt ------------------------------------- CA FOUNDATION (2ND) z 0 ROUGH FRAMING& y PLUMBING 1 INSULATION PER N.Y. STATE ENERGY CODE .�a✓- find coati dig/. -s S2c22 �-t5kAw � FINAL ADDITIONAL COMMENTS 039 O p -a3 12�tCG1 v (a�►�-- Pb u 0 - z c ] m CA t� OCA k b 1H . x a H x d b H =oo�osuFFor,t�oGy� TOWN OF SOUTHO --BUILDING DEPARTMENT w Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �y�•; �ao,��� Telephone (631) 765-1802 Fax (631) 765-9502 hqps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PE IT or offi my PERMIT NO. DO g Inspector: SEP 14, 2022 FD A lications and forms"must be filled out in'their entirety. incomplete BUILDING DEP1: Pp Y P TOWN OF SOUTHo-I) Applications will not be accepted. Where the Applicant is not the owner,an Owner's Authoriiation form(Page 2)shall be completed. , Date: �— OWNER(S)OF PROPERTY: Name: SCTM#1000- Project Address: ... .... ..D u -. �. .. _.. - - - --.. _ ._._..__.. -.-.- T l C-L7/ . .. ----- Phone# Email: 3 3 _ . Mailing Address: �. Isn /Z 9--// CONTACT PERSON:,. Name: Mailing Address: Phone#: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: ,.CONTRACTOR INFORMATION: ., Name: Mailing Address: Phone#: Email: DESCRIPTION CSF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes El No Will excess fill be removed from premises? ❑Yes ❑No 1 A� PROPERTY INFORMATION . Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ❑No IF YES, PROVIDE A COPY. I i�` iar,f- ❑ Check Box After Reading..Yvti.Therowner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to'the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, 'additions,alterations or for removal or demolition as herein described.The applicant agrees to comply.with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized insp"ectors on premises and in buildings)for necessary inspections:False statementsmade herein are . punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): --' C)S �- ��V1 ❑Authorized Agent []Owner Signature of Applicant: Date: STATE OF NEW YORK) CONNIE D.BUNCH SS: Notary Public,State of New York COUNTY OF No.01 BU6185050 Qualified in Suffolk County Commission Expires April 14,2 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer,etc.) of said owner or.owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are.true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this (s 7V odaY of , 206 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD,N.Y. NOTICE OF DISAPPROVAL DATE: November 14, 2022 TO: Jose L. Umana 51750 Main Road Southold,NY 11971 Please take notice that your application dated September 14, 2022: For permit: to install roof-mounted solar panels on an existing accessory garage at: Location of property: 51750 Route 25, Southold,NY County Tax Map No. 1000— Section 63 Block 6 Lot 4 Is returned herewith and disapproved on the following grounds: The construction is not permitted pursuant to Section 170 of the Southold Town Code and is subject to Historic Preservation Commission approval. 4,A4 Authorized Si at Note to Applicant: Any change or deviation to the above referenced application may require further review by the Southold Town Building Department. CC: file,Landmarks Mariella Ostroski,Chairperson our ur,; Town Hall Annex Anne Surchin,Vice Chair ���`°j 94-/Y 54375 Route 25 Allan Wexler `�y�� PO Box 1179 Fabiola Santana Southold,NY 11971 SDUfHOID Telephone: 631 765-1809 Tara Cubic }; p ( ) ¢, z Jeri Woodhouse = Faunaoa o kimf@southoldtownny.gov Kim E.Fuentes,Coordinator N09,0 A GO RESERVATION Town of Southold Historic Preservation Commission ® 1� I II IUB I Certificate of Appropriateness l JANUARY 26,2023 JAN 3 1 2023RESOLUTION #05.20.21.3 8u'Wirqu>JEpx Co. AMENDED 7OMY OFSO[131461_0 Owner: Jose Umana RE: 51750 Main Road, Southold, NY. SCTM# 1000-63-6-4 RESOLUTION: WHEREAS, 51750 Main Road, Southold, is on the Town of Southold Registry of Historic Landmarks; and WHEREAS, as set forth in Chapter 170 of the Town Code(Landmarks Preservation Code)of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Historic Preservation Commission prior to the issuance of a Building Permit; and WHEREAS, the applicant, Jose Umana, submitted a proposal on November 15, 2022, requesting an Amendment to a prior Certificate of Appropriateness#05.20.21.3,to install solar panels on only one accessory structure(garage) located most westerly, instead of two existing accessory structures located on the subject parcel; and WHEREAS, the scope of work includes the installationof black solar panels on the roof of the accessory structure (garage) as depicted in Engineering Plans prepared by Jacob S. Proctor, dated July 1, 2022. Sheet PV2.0 Site Plan depicts the subject structure. Solar Area will measure 518.78 sq. ft. WHEREAS, during the public hearing of January 26,2023,the applicant, Jose Umana, described his desire to make changes to the project; and NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines that the installation of Solar Panels upon the roof of most westerly accessory structure(garage)ori subject property in the above referenced application meets the criteria for approval under Section 170-8 (A)of the Southold Town Code; and Certificate of Appropriateness, HPC,Umana-AMENDMENT, SCTM No. 1000-63-6-4 BE IT FURTHER RESOLVED,that the Commission approves the request for an Amended Certificate of Appropriateness, subject to approvals by all involved agencies; and BE IT FURTHER RESOLVED,that this approval shall not be deemed effective until the required conditions have been met; and BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may require further review from the commission. Motion made by: Commissioner Cubic Motion seconded by: Commissioner Wexler VOTES: AYES: Commissioners Ostroski, Surchin, Wexler, Santana, Cubic, and Woodhouse. (6-0) RESULT: Passed Signed: ` Kim E. Fuentes Coordinator for the Historic Preservation Commission Date: January 26, 2023 Amendment to Certificate of Appropriateness Resolution No. 05.20.21.3 �l SEP 14 2022 ILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD *` iJIL FSoup-ioi_®DEPT N oi= Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a)_southoldtownny.aov — sea nd(@,southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: F ; G Ir; G or a Electrician's Name: \.T—D s License No.: 1 3 4' n /tIElec. email: Elec. Phone No: ( 7_ p I request an email c py of Certifi ate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: 0 L _ et V1 6LI Address: -7 50 dda IL4 Cross Street: ,eT Phone No.: Bldg.Permit#: 11 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESC IPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): ly% 5�a fl joy OF �1-0 Solar pavle-(� WA �-q Aq,C ro 1 v. V e--rAe rs Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES �NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[—]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 8431 Murphy Drive � s Middleton,WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intenek.com Test Verificationf Conformity In the basis of the,tests�undertaken,the sarnpte(s)of the°belowproduct have. en_,found.to,comply with the requirements of the referenced sp'ectfications at the time thetests we're taffidd,out Applicant Name&:Address: IronRidge,Inc 283571ntlustrial Blvd Hayward, CA 94545 USA` Product Description: Flush'Matint System with`XR,Rails Ratings,&Principle Fire Glass Resistance Rat�n� Characteristics =Fitish Mourit(Symmetncat} Class A Fire Ratedlor L'ow Slope applications when using Type,1, 2,3,13;19,25:and 29'listed photovoltaic modules;;Class.A Fire Rated for Steep Slope, apptica'tians with Type1,2 and 3,f'►sted photovoltaic modules Tested with',a 5'. p(distance _betwe"en_ttie:hotfom:the:moduteframe and the:roof coverinel.:nerrttie.standard_this:system_canh SCOPE OF WORK GENERAL NOTES TABLE OF CONTENTS PAGE # DESCRIPTION SYSTEM SIZE:9280W DO 696OW AC MODULES:(29)PHONO SOLAR PS320MH-20/UH 0LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY PV 1.0 COVER SHEET INVERTER(S):(29)ENPHASE IQ8-60-2-US MICROINVERTERS SOLAR PHOTOVOLTAIC INSTALLATION RACKING:IRONRIDGE XR100 THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES PV 2.0 SITE PLAN ATTACHMENT: IRONRIDGE FLASHVUE 9PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED • ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE PV 3.0 DETAIL LAYOUT OCCUPANCY: PRIMARY RESIDENCE UNDERSIGNED PV 4.0 MOUNTING DETAIL CONSTRUCTION TYPE:RESIDENTIAL ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 • ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH PV 5.0 ELECTRICAL DIAGRAM AS GeoCel 2300 CLEAR SEALANT This approval is for compliance to the current adopted building codes for the proposed 0 THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL PV 6.0 WARNING LABELS Solar System only. It is the owner's/applicant's responsibility to ensure that the proposed JURISDICTION AND THE UTILITY IS OBTAINED installation of solar systems and associated equipment is on legally permitted structures. • THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, If determined by inspection staff the proposed solar system is installed on non-permitted MECHANICAL,OR BUILDING ROOF VENTS \/E CTO R structures,any required modifications needed for code compliance will be at the IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS owner's/applicant's expense THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE e n o I n E E R s • EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED 651 W.GALENA PARK BLVD.STE. 101 PHONE(BG 1)990-1775 CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION DRAPER,UTAH H4020 WWW.VEDTORSE.DOM • INSTALLATION OFA PV SYSTEM MOUNTED ON INSTRUCTIONS" RESIDENTIAL BUILDING. 0 A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS �aS� • PR c� • 2017 NEW,2020 IRC 0 ALL WORK SHALL COMPLY WITH 2017 NEC,2020 IRC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTION. • MAIN BREAKER DEBATE: REPLACE EXISTING MAIN • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2017 NEC. BREAKER WITH NEW 80 AMP MAIN BREAKER. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. O • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. I1' • ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF 09/06/2022 REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. • CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8"ABOVE Firm License Number: COA0012807 ROOF SURFACE. VSE Project Number:U2557.0813.221 UNAUTHORIZED ALTERATIONS OR ADDITIONS TO A DOCUMENT BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF SECTION 7209(2)OF THE N.Y. 11 STATE EDUCATION LAW Vector Structural Engineering has reviewed the � existing structure with loading from the solar array \`�/��' �1�1�'r•V1 and screww connections to the existing framing. VICINITY MAP The design, the racking system,racking connections,and all other structural is by others. Mechanical,architectural,and all other nonstructural aspects of the design are by others. r aQ t Electrical is by others,unless stamped by Dean Levorsen. OWNER INSTALLED 25 x- 2 D Chu 2 b X023 Pe_'1dr, s Pr-- tit DS if(�'I JOSE UMANA OF SOVZNO�M�1t�Sg�ON 1750 MAIN RD RE ER�A��D� SOUTHOLD NY 11971 �A N,S�OR�C n j], ���� � Email:Joseumana06@gmaii.com 51750 Main 60\d, `: Phone:631-830-1484 c rr,. Southold, NY 1197-1 ... �z l� ►Jai a�� REV 1 - rl/ Cr DATE:1 July 2022 r n cv/ unizral Ho,: QVIO COVER SHEET rn rSSPV 1 .0 t dates le lal)1 Schocll SITE PLAN: 1/32"= 1'-0" SOLAR ROOF ROOF ROOF ARRAY ROOF AREA AREA COVERAGE SOLAR AREA # MOD SLOPE TILT AZIMUTH (SQFT) (SQFT) M (LBS) N AR-01 180 180 1820 518.78 1280 40.53 1182.62 29 (E)RESIDENCE (E)STRUCTURE(TYP.) LEGEND �M METER MP MAIN SERVICE PANEL © AC DISCONNECT I IFIQI IQ COMBINER I ° 13 0 ° JB JUNCTION BOX D ISP SUB PANEL (E)SUB PANEL(INDOOR) 0 u� (E) DRIVEWAY I RL � C� D �J � D (E)FENCE ROOF ACCESS POINT JAN 2 6 2023 (N)ARRAY AR-01 TOWN OF SOUTHOLD HISTORIC PRESERVATION COMMISSION ROOF MODULE LAYOUT + EQUIPMENT LOCATIONS:1/16" = 1'-0" g g ( � Vector a with to Engineer t has reviewed the crew n 1 a L) structure with loading from the solar array and screw I I connections to the existing framing.The design of the racking system,racking connections,and all othereZ .`1 structural is by others.Mechanical,architectural,and all d- 1 other nonstructural aspects of the design are by others. N Electrical is by others,unless stamped by Dean Levorsen. (E)UTILITY METER (E)CHIMNEY (N)AC DISCONNECT (TYP) yECTOR OWNER INSTALLED (N)IQ COMBINER n l3 1 n E E R S 657 W.GALENA PARK BLVD.STE. 101 PHONE(SO 1)990-r 775 DRAPER,UTAH 84020 WWW.VECTORSE.DOM OF E� (E)MAIN SERVICE PANEL, 100A RATED,240V * * CONDUIT RUN JOSE UMANA (IN THE ATTIC) 51750 MAIN RD ❑ ❑ ❑ SOUTHOLD NY 11971 10 (N)JUNCTION BOX AA A g q q q AAAAAA A Email:Joseumana06@gmail.com Iib Phone:631-830-1484 09/06/2022 BBBBBBBAAAA REVA Firm License Number: COA0012807 B B B B DATE:1 July 2022 VSE Project Number:02557.0813.221 UNAUTHORIZED ALTERATIONS OR ADDITIONS SITE PLAN TO A DOCUMENT BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF SECTION 7209(2)OF THE N.Y. PV 2.0 STATE EDUCATION LAW # MODULES PER ROOF TYPE ATTACHMENT ROOF HEIGHT FRAME MATERIAL FRAME TYPE FRAME SIZE OC SPACING ARRAY AR-01 29 COMP SHINGLE IRONRIDGE FLASHVUE ONE STORY WOOD TRUSS 2"X4" 24"O.C. AR-01 SCALE: 3/16"= 1'-0" 0,_6„ 2'-14" PITCH: 18° i POINT LOAD CALCULATION AZIMUTH: 182° 10 36-74" ITEM #OR WEIGHT TOTAL WEIGHT 4'-0" LIN FT PER(lbs) (Ibs) MODULES 29 40.78 1182.62 N 10'-6" RAILS 159.54 0.4 69.6 � I I I ATTACHMENTS 61 0.65 39.65 ARRAY AR-01 j TILT LEGS 0 3.5 0 ENPHASE I I I I I INVERTER 29 1.4 40.6 I I I I I I I I TOTAL WEIGHT 1332.4 lbs I� MODULE DIMENSION (LxW) 65.95 x 39.06= 17_88 sq`ft 14'-5" -WEIGHT PER MOUNT ^1332.4/ 61 = 21.8 Ibs/Mount 2"X4" TRUSS @ 24" I I I I WEIGHT PER SQ FT 1332.4/ 518.52 sq.ft.=2.6 Ibs/sgft O.C. II UI 1 1 1 1 1 1 I I I I I I I I I I AN Ah Aft ML Aft Im Ah IL 7d A I _ D IRONRIDGE FLASHVUE (29) ENPHASE IQ8_60_2 US JAN 2 6 2623 ATTACHMENTS MICROINVERTERS R I TOWN OF SOUTHOLD IRONRIDGE XR100 RAIL HISTORIC PRESERVATION COMMISSION SYSTEM 6'-7" OWNER INSTALLED E C T O R th �/ Vector Structural Engineering has reviewed the existing structure with loading from e solar array and screw connections to the existing framing.The design of the 3'-3" See structural letter for E fl O I r7 E E R s racking system,racking connections,and all other 651 W.GALENA PARK 8LvD.STE. IO7 PHONE(8011 990-7 775 structural is by others.Mechanical,architectural,and all roof areas that require DRAPER, UTAH aa0z0 WWW.vECTORSE.Cam other nonstructural aspects of the design are by others. tighter connection Electrical is by others,unless stamped by Dean Levorsen. 1 -o spacing than listed. * * DESIGN CRITERIA JOSE UMANA 51750 MAIN RD MODULES: SOUTHOLD NY 11971 5'-6" T-6" 29 Email:Joseumana06@gmaii.com MAX DISTRIBUTED LOAD: 3 PSF Iaygb SNOW LOAD:25 PSF Phone:631-830-1484 WIND SPEED: % 136 MPH 3-SEC GUST. REV 09/06/2022 LAG SCREWS: DATE:1 July 2022 Firm License Number: COA0012807 5/16N 2.5"MIN EMBEDMENT VSE Project Number: U2557.0813.221 NOTE: LAYOUT DETAIL UNAUTHORIZED ALTERATIONS OR ADDITIONS INSTALLERS TO VERIFY RAFTER TO A DOCUMENT BEARING A LICENSED SIZE, SPACING AND SLOPED PROFESSIONAL ENGINEER'S SEAL IS A SPANS,AND NOTIFY E.O.R. OF �� .O NOTE:-MAX.ATTACHMENT SPACING IS 4'-0" VIOLATION OF SECTION 7209(2)OF THE N.Y. ANY DISCREPANCIES BEFORE (STAGGERED) STATE EDUCATION LAW PROCEEDING. VECTOR E n 0 i n E E R 8 651 W.GALENA PARK BLVD.STE. 101 PHONE(BO l)990-1 775 DRAPER, UTAH 84020 WWW.VECTOR9E.DOM PV MODULE 0 Iib 00 09/06/2022 X4'�RVSS °CZE (E) SINGLEEA H N O E VSE Project Numbere U25Firm License Numbr: 057 08138221 2 COMPOSITE S G UNAUTHORIZED ALTERATIONS OR ADDITIONS TO A DOCUMENT BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF SECTION 7209(2)OF THE N.Y. STATE EDUCATION LAW SEE (2/PV-4.0) FOR Vector Structural Engineering has reviewed the existing structure with loading from the solar array and screw ENLARGED VIEW connections to the existing framing.The design of the racking system,racking connections,and all other structural is by others.Mechanical,architectural,and all other nonstructural aspects of the design are by others. Electrical is by others,unless stamped by Dean Levorsen. 1 ATTACHMENT DETAIL E E 0 W E PV-4.0 SCALE: 1"=l' JAN 2 b 2023 TOWN OF SOI OLD PV MODULES HISTORIC PRESERVATION COMMISSION IRONRIDGE INTEGRATED GROUNDING & END/MID �` �'� A,rao'�>,G> ► �d�I a�a3 CLAMP IRONRIDGE FLASHVUE ATTACHMENTS 4y IRONRIDGE XR100 RAIL >> `� OWNER INSTALLED ALUMN. "L" BRACKET W/3/8" SS BOLT & NUT (E) SINGLE LAYER OF COMPOSITE SHINGLE JOSE UMANA IRONRIDGE FLASHVUE 51750 MAIN RD FLASHING 5/16"X4.25" SS LAG SCREW SOUTHOLD NY 11971 WITH MIN 2%Z"THREAD Email:Joseumana06@gmall.com 2"X4" TRUSS @ 24" O.C. EMBEDMENT, SEALED Phone:631-830-1484 PENETRATION REV A DATE:1 July 2022 MOUNTING DETAIL 2 ATTACHMENT DETAIL ( section view) PV-4.0 SCALE: NTS PV 4.0 CONDUIT SCHEDULE GROUND SYSTEM SIZE:9280W DC,6960W AC NOTE: **ENVOY BREAKER CAN BE 10A OR 15A IN IQ COMBINER BOX, # CONDUIT CONDUCTOR NEUTRAL(WHITE) (GREEN) (BARE COPPER) ENPHASE MICRO INVERTERS ARE EQUIPPED WITH RAPID REFER TO TECHNICAL BRIEF IN ATTACHED SPEC SHEETS. (RED/BLACK) SHUTDOWN FUNCTION PER NEC 690.12. 1 NONE ENPHASE Q-CABLE NONE NONE (1)#6 • MAIN BREAKER DEBATE: REPLACE EXISTING MAIN 2 3/4"EMT (4)10 AWG NONE (1)6 AWG NONE BREAKER WITH NEW 80 AMP MAIN BREAKER. THHNITHWN-2 THHN/THWN-2 3 3/4"EMT (2)8 AWG (1)8 AWG (1)6 AWG NONE THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 3 (N)LOCKABLE EXISTING WIRING BLADE TYPE 3 IQ COMBINER AC DISCONNECT BOX 2 1 2P 2P 15A** 80A PHONO SOLAR (MONITORING) NEW PS320MH-20/UH 15 ENPHASE IQ8-60-2-US IVI IVI IV' (1)CIRCUIT OF(15)MODULES 2P STRING A,ARRAY 1 20A-2P 40A SOLAR 1 BREAKER PHONO SOLAR AT OPPOSITE 1A 2A 3A PS320MH-20/UH 20A-2P END OF 14 ENPHASE IQ8-60-2-US BUSBAR (1)CIRCUIT OF(14)MODULES NEW 60A AC I STRING B,ARRAY 1 JUNCTION BOX DISCONNECT EXISTING I EXISTING METER ENPHASE IQ MAIN PANEL _ EAD UTILITY SERVICE MIN RATED COMBINER BOX, (2-POLE 100A BUSBA �] NEMA3R 125A RATED UNFUSED) END FED D -I INVERTERS RATING L'J (X-IQ-AM 1-240-4C) JAN 2 b 2023 D MAKE ENPHASE TOWN OF SOI THOLD HISTORIC PRESERVATION COMMISSION MODEL IQ8-60-2-US MAX INPUT CONDUCTOR SIZING CALCULATIONS CURRENT 15A CIRCUIT Icont(690.8(B)(1)) SPECIFIED AMPACITY @ AMBIENT CURRENT COND.OF USE APPLIED MAX POWER 240W DESCRIPTION CURRENT Imax(690.8(A)) calc CONDUCTOR 90C TEMP c CARRYING (690.8(B)(2))calc (AC) PV SOURCE 15.00A x 1.25= COND40A x 0.96(am b.temp.)x0.80 OWNER INSTALLED NOM.AC 240V CIRCUIT A 15.00A 15.00A 18.75A #10 THWN-2 40A 31-35 4-6 (raceway fill)=30.72A VOLTAGE PV SOURCE 40A x 0.96(am b.temp.)x0.80 MAX AC 1A CIRCUIT B 14.00A 14.00A 14.00A x 1.25= 17.5A #10 THWN-2 40A 31-35 4-6 (raceway fill)=30.72A CURRENT CEC ° COMBINER BOX 29.00A 29.00A 29.00A x 1.25= #8 THWN-2 55A 31-35 1-3 55 x 0.96(raceway(fll b 52 8A)x1 EFFICIENCY 97% OUTPUT 36.25A ) MODULE AND ARRAY RATINGS: (29)MODULES) TERMINAL TEMPERATURE RATING CONSIDERATIONS AMPACITY @ JOSE UMANA SOLAR MODULE RATINGS (STC) CIRCUIT A CIRCUITI3 TERMINAL TEMP SPECIFIED 51750 MAIN RD RATING CONDUCTOR CIRCUIT DESCRIPTION CURRENT Icont TERMNAL TEMP. MAKE PHONO SOLAR SERIES 1 1 RATING SOUTHOLD NY 11971 PV SOURCE CIRCUIT A 15.00A 15.00A x 1.25= 18.75A 75C #10 35A Email:Joseumana06@gmaii.com MODEL PS320MH-20/UH PARALLEL 15 14 PV SOURCE CIRCUIT B 14.00A 14.00A x 1.25= 17.5A 75C #10 35A Phone:631-830-1484 COMBINER BOX OUTPUT 29.00A 29.00A x 1.25=36.25A 75C #8 50A REV Imp 9.69A Imp 15.OA 14.OA VOLTAGE DROP CALCULATIONS DATE:1 July 2022 Vmp 33.01V Vmp 240V 240V CIRCUIT DESCRIPTION LENGTH I Ohms/kFt V CALC Vdrop Isc 10.13A Isc 15.OA 14.OA PV SOURCE CIRCUIT A 50Ft 15.00A 0.9989 240V b0'x 15.00A x 2 x 0.9989/1009/240V= 0.62% ELECTRICAL Voc 39.92V Voc 240V 240V PV SOURCE CIRCUIT B 50Ft 14.00A 0.9989 240V 50'x 14.00A x 2 x 0.9989/1000'/240V= 0.58% COMBINER BOX OUTPUT 30Ft 29.00A 0.6282 240V 30'x 29.00A x 2 x 0.6282/1000'/240V= 0.46% Pmax 320W Pmax 360OW 3360W PV 5.0 %Voc/C -0.306% INSTALL ON THE UTILITY METER INSTALL ON THE AC DISCONNECT PHOTOVOLTAIC THIS SERVICE METER AAC DISCONNECT I CAUTION : IS ALSO SERVED BY A POWER TO THIS BUILDING IS ALSO SUPPLIED RATED AC OUTPUT CURRENT: 29.00A FROM THE FOLLOWING SOURCES WITH PHOTOVOLTAIC SYSTEM DISCONNECTS LOCATED AS SHOWN: NOMINAL OPERATING AC VOLTAGE: 240V INSTALL ON THE MAIN BREAKER PANEL PHOTOVOLTAIC SOLAR SUB PANEL PV ARRAY PHOTOVOLTAIC SYSTEAC DISCONNECT (INDOOR) EQUIPPED RAPIDD • ELECTRIC SHOCK HAZARD MAIN SERVICE RAPID A- . . • PANEL ARRAY - WN TERMINALS ON THE LINE AND IQ COMBINER UTILITY METER PV LOAD SIDES MAY BE ENERGIZED (NP.) IN THE OPEN POSITION AC DISCONNECT TO BE INSTALLED IN ACCORDANCE WITH SECTION 690.56(C): 51750 Main Rd,Southold,NY 11971 A CAUTION SOLAR PV SYSTEM D SOLAR ELECTRIC SYSTEM CONNECTED D EQUIPPED WITH JAN 2 0 2023 INSTALL INSIDE THE MAIN BREAKER RAPID SHUTDOWN TOWN OFSOUTHOLD PANEL, NEXT TO THE SOLAR BREAKER HISTORIC PRESERVATION COMMISSION SOLA PANELS ELS OWNER INSTALLED PV PA I POWER SOURCE INSTALL ON THE PV OUTPUT CONNECTION. AC COMBINER BOX DO NOT RELOCATE THIS TURN RAPID SHUTDOWN SWITCH TO (IF APPLICABLE) OVERCURRENT DEVICE THE"OFF"POSITION TO SHUT DOWN PV SYSTEM AND REDUCE JOSE UMANA SHOCK HAZARD IN THE ARRAY 51750 MAIN RD SOUTHOLD NY 11971 PHOTOVOLTAIC INSTALL EVERY 10 FEET ON EXTERIOR CONDUIT. PHOTOVOLTAIC SYSTEM Email: 631-830-1484 gmail.com SOLAR BREAKER - Phone:s31-aso-lana COMBINER PANEL WARNING: PHOTOVOLTAIC REV A DO NOT RELOCATE THIS POWER • - DO NOT ADD LOADS DATE:1 July 2022 OVERCURRENT DEVICE WARNING LABELS PV 6.0 Phana, salar% Twinplus Module Mono Perc/310-325W ]019 TOP PERFORMER ESL ONV•GL Bloomberg Tier PV MODULE NEW ENERGY FINANCE RELIABILITY SCORECARD I PID Resistant Better Shading Tolerance More Reliable ® Lower hot spot temperature More Power Low power loss in cell connection Low temperature coefficient(Pmax):--0.417%/OC Low NOCT:45±2°C 100% M 12-year product warranty ®25-year linear performance warranty 3 oar 0- oo 614 a� > 70 % 2X6o r3 0 5 10 15 20 25 O Industry standard M Phono Solar Year Cells 0� D _ SINOMACHISUMEC ■� EN-20200220 SUMEC GROUP CORPORATION ELECTRICAL TYPICAL VALUE-S • • • • • • .de • • • • • • Type Monocrystalline 156.75mm x 78.38mm Rated Power(Pmpp) 310W 315W 320W 325W Tolerance 0-+5w Rated Current(Impp) 9.51 9.60 9.69 9.78 Rated Voltage(Vmpp) 32.58 32.79 33.01 33.21 Short Circuit Current(Isc) 9.95 10.04 10.13 10.22 Open Circuit Voltage(Voc) 39.58 39.74 39.92 40.10 Module Efficency(%) 18.66 18.96 19.26 19.56 NOCT(Nominal Operation Cell Temperature) 45±2C Voltage Temperature Coefficient -0.306%/°C Current Temperature Coefficient +0.046%f°C Power Temperature Coefficient -0.417%/°C MECHANICAL .R.CTER-ISTICS ELECTRICAL CHARACTERISTICS Length: 1675mm(65.95 inch) Dimension(Lx W x H) Width:992mm(39.06 inch) 350 Height:35mm(1.38 inch) 300 Cell ' SC -Incident Irrad.=1000WJm2_ 250.__ _ -Incident Irrad.BOOW/m2 Weight 18.5kg(40.78 lbs) -ocidenJrrad:500WIm2 _ €2W- ENPHASE. L: ENPHASE m - ATTENTION IQ8 Series Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC Easy to install power to AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling • a 3= High productivity and reliability I 5 i Produce power even when the year limited grid is down warranty 1 - -- More than one million cumulative Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules Microgrid-forming WIN-- CERTIFIED Complies with the latest advanced grid support Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements IQ8SE-DS-0001-01-EN-US-2022-03-01 IQ8 Series Microinverters INPUT 1• 1 1: .I A: 1: 1: 1: 1 08 1: Commonly used module pairings' W 235-350 235-440 260-460 295-500 320-540+ 295-500+ Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current3[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT 1 A: .1 A: A: A: 1: 1 A: 1: Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal(L-L)voltage/range" V 240/211-264 208/183-250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuits 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency % 97 97 97 97.5 97 97 Night-time power consumption mW 60 D 17 I I= M MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40°F to+140°F) JAN 2 b 2623 Relative humidity range 4%to 100%(condensing) TOWN OF SOUTHOLD DC Connector type MC4 HISTORIC PRESERVATION COMMISSION Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor 1 CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)The IQ8H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility(3)Maximum continuous input DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal if required by the utility.(5) Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-01 Data Sheet Enphase Networking Enphase The Enphase IQ Combiner 4/4C with Enphase IQ Gateway and integrated LTE-M1 cell IQ Combiner 4/4C modem (included only with IQ Combiner 4C) X-IQ-AM1-240-4 consolidates interconnection equipment X-IQ-AM1-240-4C into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series eE"PHase busbar assembly. h Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect cellular modem (CELLMODEM-M7-06-SP-05),included only with IQ Combiner 4C Includes solar shield to match Enphase IQ Battery — -- aesthetics and deflect heat Flexible networking supports Wi-Fi, la Ethernet,or cellular • Optional AC receptacle available for PLC bridge i Provides production metering and consumption monitoring Simple • Centered mounting brackets support single i stud mounting "r Supports bottom,back and side conduit entry c _- Up to four 2-pole branch circuits for 240 VAC • _ _ • plug-in breakers(not included) X-IQ-AM1-240-4C BOA total PV or storage branch circuits I I ' Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's j UL listed X-IQ-AM1-240-4 LISTED E N P H A S E• To learn more about Enphase offerings,visit enphase.com i.� Enphase IQ Combiner 4/4C MODEL NUMBER IQ Combiner 4 (X-IQ-AM1-240-4) IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes a silver solar shield to match the IQ Battery system and IQ System Controller and to deflect heat. IQ Combiner 4C(X-IQ-AMI-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05),a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in the installation area.)Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan for COMMS-CELLMODEM-M1-06 Ensemble sites CELLMODEM-M1-06-SP-05 4G based LTE-M1 cellular modem with 5-year Sprint data plan CELLMODEM-M1-06-AT-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. BRK-10A-2-240V Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-24OV-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support BRK-20A-2P-240V-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support EPLC-01 Power line carrier(communication bridge pair),quantity-one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board(PCB)for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating 65A Max.continuous current rating(input from PV/storage) 64A Max.fuse/circuit rating(output) 90A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.total branch circuit breaker rating(input) 80A of distributed generation/95A with IQ Gateway breaker included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers MECHANICAL DATA Dimensions(WxHxD) 37.5 x 49.5 x 16.8 cm(14.75'x 19.5"x 6.63").Height is 21.06"(53.5 cm)with mounting brackets. Weight 7.5 kg(16.5 lbs) RECE � WE Ambient temperature range -40°C to+4.6°C(-40°to 115°F) D Cooling Natural convection,plus heat shield d Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors TOWN OF SOUTHOLD 60 A breaker branch input:4 to 1/0 AWG copper conductors HISTORIC PRESERVATION COMMISSION Main lug combined output:10 to 2/0 AWG copper conductors Neutral and ground:14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05,CELLMODEM-M1-06-AT-05(4G based LTE-M1 cellular modem). Notethat an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) COMPLIANCE Compliance,IQ Combiner UL 1741,CAN/CSA C22.2 No.107.1, 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Consumption metering:accuracy class 2.5 Compliance,IQ Gateway UL 60601-1/6ANCSA 22.2 No.61010-1 To learn more about Enphase offerings,visit enphase.com u E N H A S E, ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of Enphase Energy,Inc.Data subject to change.10-21-2021 TECHNICAL BRIEF u ENPHASE. 10A and 15A Circuit Breakers for the Enphase AC Combiner Enphase allows you to remove spare circuit breakers and to downsize the combiner breakers within the Enphase AC Combiner Box" Overview The Enphase AC Combiner Box- (XAM1-120) is a UL listed assembly for the purpose of combining circuits and providing monitoring in an Enphase Microinverter system. See our Certificate of Compliance from UL. Some Authorities Having Jurisdiction(AHJs) have inquired about details related to the internal manufacturing of the AC Combiner product. Since the assembly has been evaluated and listed by UL for the applications supported as detailed in the product manual,the internal workings of the AC Combiner box do not require additional evaluation for compliance with the National Electrical Code. As such,the busbar rating and AC circuit breaker ° ratings inside the AC Combiner Box do not require additional evaluation. However,Enphase does provide some guidance for modifying the AC Combiner Box circuit breakers for a given application.We allow for and support the removal • of spare circuit breakers,and for downsizing the • Combiner Breakers within the AC Combiner Box. • - • • F • Always follow removal instructions and torque • • requirements from the installation documentation • w • q • a • . when removing or swapping breakers. I • a • Combiner Replacement Breakers breakers We have evaluated the following 15A and 10A circuit breakers for use in the AC Combiner Box. You can order replacement circuit breakers from — safe Circuits at: JAN 2 6 2023 Safe Circuits 1-800-863-2134 TOWN OF SOUTHOLD http://www.safecircuits.com/ HISTORIC PRESERVATION COMMISSION Specifications ordering Info Manufacturer Info Safe Circuits Part Number CBI Electric Part Number 10A,2 pole,240V QL29MS10 QL-2(13)-DM-10A 15A,2 pole,240V QL29MS15 QL-2(13)-DM-15A 1 ©2016 Enphase Energy Inc.All rights reserved. July 2016 r IRON RIDGE Flush Mount System 6 `OT Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and Cn t1f1 is also why our products are fully certified, code compliant and backed by a 20-year warranty. u D JAN 2 6 2023 023 Strength Tested PE CertifiedTOWN OF so OLD HISTORIC PRESERVATION COMMISSION All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. R=1=9_02 XR Rails O XR10 Rail XR100 Rail XR1000 Rail Bonded Splices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish • Clear anodized finish • Forms secure bonding Clamps & Grounding O UFOs Stopper Sleeves Grounding Lugs Microinverter Kits _.&ML- - - � =mow— Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount MIs or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled & lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • Sized to match modules • Single tool installation • Kit comes assembled • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 Attachments O FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs 1_0 .74 Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System JAN 2 6 2023 with superior waterproofing. attachment. to roof attachments. to various heights. TOWN OFSOU IHu- • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options • Works with vent flashing HISTORIC PRESERVATION COMMISSION • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • 4"and 7" lengths • Mill and black finish • Clear and black finish • Assembled and lubricated • Ships assembled Resources Design Assistant P NABCEP Certified Training -- � lGo from rough layout to fully NABCEP Earn free continuing education credits, engineered system. For free. while learning more about our systems. _ — Go to IronRidge.com/design Go to IronRidge.com/training Q .. .11 MUM ZT."rTTNf7.T.r1r. ... . :A. ... .. .. .. ®��® ANAL IRON RIDGE UFO Family of Components Simplified GrOUnclincg for Every Application The UFO family of components eliminates the need for v,r separate grounding hardware by bonding solar modules _ directly to IronRidge XR Rails.All system types that feature the UFO family—Flush Mount,Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system.This leads to safer and more reliable installations. R Stopper Sleeve Universal Fastening Object(UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XR onto the UFO,converting it into Rails.It comes assembled and lubricated,and a bonded end damp. can fit a wide range of module heights. t _'.�v fes.. • /. .� JAN 2 b 20;3 Bonded Splice Each Bonded Splice uses '1.-''•` "• " TOWN OF SOUTHOLD r-; HISTORIC PRESERVATION COMMISSION self-drilling screws to tomo a secure connection.No bonding strap needed. Grounding Lug A single Grounding Lug Bonded Attachments connects an entire row The bonding bolt attaches of PV modules to the and bonds the L-loot to the grounding conductor. rail.It is installed with the same socket as the rest of the system. System Diagram - _ - - - - - - - - - -m= - - - - _ - - - - - - - - � BILL - - - - - - -- - - - - - - = - - - --- - - - . . _ - -m- - - - - - _ - -- - = _ _ _ _ _ _ - - - - = _ --- - - - - -m-= - - - - - = = - - - - Q UFO 4 Stopper Sleeve • Grounding Lug Bonded Splice —1— Ground Wire Q Approved Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL CertificationD (� e a e . ® V The IronRidge Flush Mount, • A - • a ® • D Tilt Mount, and Ground Mount XR Rails r r XR1000 Only JAN 2 6 2023 Systems have been listed to UL 2703 by Intertek Group plc. UFO/Stopper d TOWN OF FS OLD UL 2703 is the standard for Bonded Splice d r NSA HISTORIC PRESERVATION COMMISSION evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array systems. It ensures these devices Microinverters Enphase-M250-72, M250-60, M215-60,C250-72 will maintain strong electrical and &Power Darton-MIG240, MIG300, G320, GMM mechanical connections over Optimizers SolarEdge- P300, P320, P400, P405, P600, P700, P730 an extended period of time in extreme outdoor environments. Fire Rating Class A Class A NIA FModules Tested or Evaluated with over 400 Framed Modules Go to IronRidge.com/UFO Refer to installation manuals for a detailed list. R ��� - r = .�. IRONRIDGE Class A Fire Rating Background All roofing products are tested and classified for their ability to resist fire. Test Setup Recently, these fire resistance standards Soku Modular Solar modules are given a Type were expanded to include solar equipment classification based on their as part of the roof system_Specifically, this materials and construction. requires the modules, mounting hardware Mounting system and roof covering to be tested together as Mounting is tested as part of a system that includes We-tested a system to ensure they achieve the same modules and tire-rated root covering. fire rating as the original roof covering. Root covering Roof covering products are given a Adoption of these new requirements will Fn:Class Rating of A,B or C based begin in California in 2015 and extend to on their tested fire resistance. the rest of the country in 2016. Burning Brand Test IronRidge Certification In August 2014, IronRidge was the first company to receive a Class A Fire Rating— the highest possible rating—from Intertek Group plc., a Nationally Recognized Testing A buming wooden block is placed on module as a fan blows at 12 mph. Laboratory. Flame cannot be seen on underside of roof within 90 minutes. IronRidge Roof Mount products were tested Spread of Flame rest on flat and sloped roofs in accordance with the new UL 1703&UL 2703 test standards. The testing evaluated the system's ability to resist flame spread,burning material and iA. structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Flame at southern edge of roof is aimed up the roof as a fan blows at 12 Rating on your next project. mph.The flame cannot spread 6 feet or more in 10 minutes. JAN 2 6 D 7SteepSlope79.5deg.) Flush Type 1 &2 Class A 2023 TOWN OF OUTHOLD HISTORIC PRESERVATION COMMISSION Flush Fnl Type 1 Class A Low Slope (<9.5 deg.) Tilt EEI Type 1 Class A 'Can be installed on Ctrs q B,&C roofs. Frequently Asked Questions What is a"module type"? What attachments and flashings are deemed compatible with Class A? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters Attachments and their respective flashings are not and 2 fire performance parameters.The purpose of constituents of the rating at this time.All code-compliant this classification is to certify mounting systems without flashing methods are acceptable from a fire rating needing to test it with every module. standpoint. What roofing materials are covered? What mounting height is acceptable? All fire rated roofing materials are covered within this The UL testing was performed at a height of 5"-The certification including composition shingle, clay and code does not specify minimum or maximum height.The cement tile,metal, and membrane roofs. Iron Ridge Class Arating covers all heights as long as they fit within the"flush mounted"category. What if I have a Class C roof,but the jurisdiction now requires Class A or B? Am I required to install skirting to meet the fire code? Generally,older roofs will be"grandfathered in",and will not require re-roofing-However, if 50%or more of the No, IronRidge achieved a Class Afire rating without any roofing material is replaced for the solar installation the additional racking components. code requirement will be enforced. What determines Fire Classification? Where is the new fire rating requirement code listed? Fire Classification refers to a fire-resistance rating 2012 IBC: 1509.7.2 Fire classification. Rooftop system for roof covering materials based on their ability mounter/photovoltaic systems shag have the same fire to withstand fire exposure. classification as the roof assembly required by Section 1505. Class -effective against severe fire exposure Class B-effective against moderate fire exposure Class C-effective against light fire exposure Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC What if the roof covering is not Class A rated? refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas(WUI) and The IronRidge Class A rating will not diminish the fire for very high fire severity areas.Many of these areas are rating of the roof,whether Class A, B,or C. found throughout the western United States.California has the most Class A and B roof fire rating requirements, What tilts is the tilt mount system fire rated for' HL �] due to wild fire concerns. V IS D The tilt mount system is rated for 1 degrees and up and JAi�Y ....r Are standard mid clamps covered? any roof to module gap, or mounting height. 2 0 2023 TOWN OF SoLrrwni n Mid clamps and end clamps are considered part of the HISTORIC PRESERVATION COMMISSION PV"system", and are covered in the certification. More Resources E3Fire Rating Certificate Engineering Certification Letters Visit our website to download the official UL We offer complete engineering resources 2703 certification document. and pre-stamped certification letters. Go to IronRidae•com Go to IronRidae_com MG . .,. r. /Q® IRONRIDGE FlashVuell Moving Flashing Forward We set out to design a flashing that checked all the boxes: fully waterproof, fast and easy to install correctly, economical, and strong enough to handle every environmental condition. FlashVue does it all. The optimized flashing design features a large viewport, for easy alignment with the pilot hole.And , the GripCap and GripCap+sit snugly in place, so the lag can be driven single-handedly. -- Three-Tier Water Seal, Reimagined FlashVue's seal architecture utilizes three layers �.. of protection.The viewport is elevated 0.30",and provides a"friction-fit'for the GripCap.The GripCap - - fully covers the viewport while a sealing washer _ adds another layer of protection.And an EPDM _ washer and lag bolt"seal the deal'in the stack. GripCap&GripCap+ f fp" . The 3600 capable GripCap(2.74" tall)and GripCap+(3.74"tall)can be ` placed in any orientation,and provide,a "friction4it"for easy installs.Push snug into the viewport,without worrying it will roll away or rotate while driving the lag. - J l N 2 6 2023 I 0 0.75 \ �. TOWN OF SOUTHOLD \ t F s HISTORIC PRESERVATION COMMISSION Go. Large Viewport in Flashing Intertek The large viewport makes it easy to align the flashing with the pilot hole,and Triple Certified to / i — drive the lag centered into the rafter.The Protect the Roof- elevated rim not only provides a sturdy UL 2703,441 (27) ° dock for the GripCap or GripCap+,but TAS 100(A)-95 increases water-shedding capabilities. See Your Pilot Holes Largepeg0 • e • - • i e e • e • er(lojp 0.75" 1` Solve Roof Undulations A 0 e 00 0 o ee e e e w_hqn un • abee e- GripCap _ lip .i --- -------_..--- - 3ripcTi rip 1 Gripce Uneven Roof Surfaces >1" Trusted Strength & Certification1 3Attachment Loading ' FlashVue has been tested and rated to support 1161 (Ibs) of uplift and 353 (Ibs) of lateral load. JAN 2 1 �� Structural Certification TOWN OF SOUTNOo M Designed and certified for compliance with the International Building Code &ASCE/SEI-7. HISTORIC PRESERVATION COMMISSION 13 Water Seal Ratings Passed both the UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. UL 2703 Listed System Conforms to UL 2703 mechanical and bonding requirements. See Flush Mount Manual for more info. to e e .._ .. ..� -. .... .. .. ... _ :ee ✓ ... ..... .. .. e ®��® r IRON RIDGE FlashVue 1 2 3 4 4 ITEM NO DESCRIPTION QTY IN KIT 1 BOLT, LAG 5/16 X 4.25" 1 2 WASHER, EPDM BACKED 1 3 FM FLASHING, MILL OR BLACK 1 4 GRIP CAP, MILL OR BLACK 1 FLASHVUE PART NUMBER DESCRIPTION FV-01-M1 FLASHING, FLASHFOOT, MILL FV-01-B1 FLASHING, FLASHFOOT, BLACK 1) BOLT, LAG 5/16 x 4.25" 0.61 .26 5/16 THD D 4.25 JAN 2 b 701.3 7/16"Head S 1— TOWN OF SOUl'HOLD HISTORIC PRESERVATION COMMISSION Property Value Material 300 Series Stainless Steel Finish . Clear V1.0 2) Washer, EPDM Backed .14 0.35 Property Value OMaterial 300 Series Stainless Steel 0.75 Uj Finish Clear 3) Grip Cap .40-� .36 1.00 i + 2.74 Property Value Material Aluminum Finish Mill/Black 4) FM Flashing 8.0 — .32 D 12.o JAN 2 6 2023 TOWN OF SOUTHOLD Property Value HISTORIC PRESERVATION COMMISSION Material Aluminum Finish Mill/Black V1.0 8431 Murphy Drive Vttertelc Middleton,WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity In the basis of the tests undertaken,the sample(s)of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name&Address: IronRidge, Inc. 28357 Industrial Blvd Hayward, CA 94545- USA 4545USA Product Description: Flush Mount System with XR,Rails. . Ratings&Principle Fire Class Resistance Rating: Characteristics: -Flush Mount(Symmetrical). Class A•Fire Rated for Low Slope applications when using Type 1, 2,3,13,19,.25 and 29 listed photovoltaic modules. Class A Fire Rated for Steep Slope . . applications with Type1,2 and 3, listed photovoltaic modules. Tested with a 5"gap(distance between the bottom the module frame and the roof covering),per the standard this system can be installed at any-gap allowed by the manufacturers installation instructions. No perimeter guarding is required. This rating is applicable with any IronRidge or 3'rd party roof anchor. Models: IronRidge Flush Mount with XR:Rails: Brand Name: IronRidge.Flush Mount Relevant Standards UL 2703(Section 15.2 and 15.3)Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices,and Ground Lugs for Use with Flat-Plate Photovoltaic Modules 'and Panels, First Edition dated Jan.28,2015 Referencing'UL1703 Third Edition dated Nov. 18, 2014,(Section 31.2)Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. Verification Issuing Office: Intertek Testing Services NA,'Inc. ' 8431 Murphy Drive 'Middleton,WI 53562 Date of Tests: .08/27/2014 to 03/17/2015 - Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001'&101999492MID-001ar1-cr1, 104428358MID-001 EEV Revision Summary 8/27/2020 Added type 13, 19,,25 and 29 to system, update address. This verification is part of the full test report(s)and should be read in conjunction with them.This report does not automatically imply product certification. Completed by: Chris Zimbrich Reviewed by: Chad Naggs D E C Title: Technician I,Fire Resistance -Title: Technical Team Lead,Fire Resistance' D JAN 2 6 2023 Signature: Signature: Date: . 08/27/2020 Date: 08/27/2020 TOWN OF SOUTHOLD HISTORIC PRESERVATION COMMISSION This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement for any loss,expense or damage occasioned by the use of this Verification.Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material,product or service is or has ever been under an Intertek certification program. GFT-OP-11a(24-MAR-2014) SCOPE OF WORK GENERAL NOTES TABLE OF CONTENTS .YSTEM SIZE:704OW DC 5280W AC PAGE# DESCRIPTION 40DULES:(22)PHONO SOLAR PS320MH-20/UH is LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY PV 1.0 COVER SHEET VVERTER(S):(22)ENPHASE ENERGY INC.IQ8.60.2-US[24oV]MICROINVERTERS SOLAR PHOTOVOLTAIC INSTALLATION TACKING:IRONRIDGE XR100 • THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES PV 2.0 SITE PLAN tTTACHMENT:IRONRIDGE FLASHVUE • PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED • ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE PV 3.0 DETAIL LAYOUT ICCUPANCY:PRIMARY RESIDENCE UNDERSIGNED PV 4.0 MOUNTING DETAIL :ONSTRUCTION TYPE:RESIDENTIAL ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 is ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH PV 5.0 ELECTRICAL DIAGRAM AS GeoCel 2300 CLEAR SEALANT This approval is for compliance to the current adopted building codes for the proposed THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL PV 6.0 WARNING LABELS Solar System only.It is the owner's/applicant's responsibility to ensure that the proposed JURISDICTION AND THE UTILITY IS OBTAINED installation of solar systems and associated equipment is on legally permitted structures. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, If determined by inspection staff the proposed solar system is installed on non-permitted MECHANICAL,OR BUILDING ROOF VENTS structures,any required modifications needed for code compliance will be at the IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS VECTOR owner's/applicant's expense THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE • EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED E In o i n e e a e CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION --ract11 99xJ!9 . is INSTRUCTIONS" INSTALLATION OFA PV SYSTEM MOUNTED ON RESIDENTIAL BUILDING. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS • 2017 NEW,2020 IRC • ALL WORK SHALL COMPLY WITH 2017 NEC,2020 IRC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTION. * �, • MAIN BREAKER DERATE' • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2017 NEC. REPLACE EXISTING MAIN BREAKER WITH NEW 90 AMP MAIN BREAKER. is PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY •e",• GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. is MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 0 • ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION STANDARDSIMANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. 06/15/2023 • CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 718"ABOVE Firm License Number:081423 ROOF SURFACE. VSE Project Number:U2557.0813.221 See structural letter for UNAUTHORIZED ALTERATIONS OR ADDITIONS TO A DOCUMENT BEARING A LICENSED roof areas that require PROFESSIONAL ENGINEER'S SEAL IS A tighter connection VIOLATION OF SECTION 7209(2)OF THE N.Y. spacing than listed. STATE EDUCATION LAW VICINITY MAP Vector Structural Engineering has mAewed the existing shudure wth loading tram the solar array and mm w,neaons to the existing framing.The design of the rocking system,rocking esenectlons,recall other awcturalIsbyothers.Mernamcal,amhileaural.and all OWNER INSTALLED �.�1ChCI nGeIO othera—buchnalaspects ofthe designareby°chars. t El-deal is by others,unless stamped by Dean I.—m n. s latrick's Rc Church %�j I JOSE UMANA r 51750 MAIN RD j� � SOUTHOLD NY 11971 Email:Joseumana06@gmall.com touthold, 1750 Main Rd, X9.4 AMEND. Phone:631-830-1484 ray NY 11971... 1�`�' ;ENT' REVA l 1 I Q\ DATE:14 JUNE 2023 e Friest-Grattari Funeral Home 1 9 �% COVER SHEET F Southold `�,�I` PV 1.0 no Associates,4 Elementary School SITE PLAN:1/32"=V-0" SOLAR ROOF ROOF ROOF ARRAY ROOF AREA AREA COVERAGE SOLAR AREA#MOD SLOPE TILT AZIMUTH (SQFT) (Si M (LBS) N AR-01 18° 18° 11 393.56 1280 40.53 897.16 22 (E)RESIDENCE (E)STRUCTURE(TYP.) - LEGEND --- ___ __ __- ❑M METER MP MAIN SERVICE PANEL ©AC DISCONNECT I IQ IQ COMBINER Iis JUNCTION BOX I SP I� 2 (E)SUB PANEL(INDOOR) SUB PANEL I� Ito (E)DRIVEWAY n (E)FENCE ROOF ACCESS POINT (N)ARRAY AR-01 ROOF MODULE LAYOUT+EQUIPMENT LOCATIONS:1/16"= V-0" Vector structural Engineering has reviewed the existing structure Wit,loading[mm the eater array and screw nnachons to the ending homing.The design m me eking system, N system structural"by oruhcrsngMaecnhnasatla%`oNl,ea ntl all other nous""' I aspects of the design are by others. Elecbical Is by others,unless stamped by Dean Levarsen. (E)UTILITY METER (E)CHIMNEY (N)AC DISCONNECT (N)IQ COMBINER OWNER INSTALLED >Ve n VECTOR G t n E E R 8 651 W.°4tEr+n p"a[etv°.srE.l01 p"nE l6O 11 990 1��5 (E)MAIN SERVICE PANEL, OF 100A RATED,240V Q`C P�fp ° 0`S CONDUIT RUN JOSE UMANA * * (IN THE ATTIC) 51750 MAIN RD ❑ ° ❑ ❑ o (N)JUNCTION BOX SOUTHOLD NY 11971 ❑ O A A A A A A A A A A A N Email: :6seu @gmail.com c•7 Phone:631-830-1484 (N)ARRAY AR-01 BBBBBBRBB BB REV - 06/15/2023 DATE:14 JUNE 2023 Firm License Number:081423 VSE Project Number;U2557.0813.221 SITE PLAN UNAUTHORIZED ALTERATIONS OR ADDITIONS See structural letter for TO A DOCUMENT BEARING A LICENSED roof areas that require PROFESSIONAL ENGINEER'S SEAL ISA tighter connection \/ VIOLATION OF SECTION 7209(2)OF THE N.Y. g P V 2.0 STATE EDUCATION LAW spacing than listed. #MODULES PER ROOF TYPE ATTACHMENT ROOF HEIGHT FRAME MATERIAL FRAME TYPE FRAME SIZE OC SPACING ARRAY .R-01 22 COMP SHINGLE IRONRIDGE FLASHVUE ONE STORY WOOD TRUSS 2"X4" 24"O.C. AR-01 0'-6" 2'-104-1" ��WECTOR SCALE:3/16"=1'-0" 36'-74" E n o I n E E R e PITCH:18° o, .. »a AZIMUTH:182° 4'-0" 4,OF 8J1' IJ ARRAY AR-01 ' I ' ' 40 06/15/2023 ( ( I ( I ( Firm License Number:081423 VSE Project Number:U2557.0813.221 UNAUTHORIZED ALTERATIONS OR ADDITIONS TO A DOCUMENT BEARING A LICENSED I I I I ( PROFESSIONAL ENGINEER'S SEAL IS A 2"X4"TRUSS VIOLATION OF SECTION 7209(2)OF THE N.Y. STATE EDUCATION LAW 24"O.C. veno,sbunb,,el 4'-5" ng In nee dewedthe-slingsww,ewdnloadngi111.°m theaolararrayendaeew connections tp the,ealsgng naming.The design of the rang system,cacki g connections,and all caber snucMral Is by others.Mechanical,awnteconai,and all w IRONRIDGE FLASHVUE ATTACHMENTS (22)ENPHASE ENERGY INC.IQ8-60-2-US 1240VI MICROINVERTERS ethe,nonechael aalacle of the design am by ethers. IRONRIDGE XR100 RAIL SYSTEM FJegdcal is by others,unless stamped by Deen Lewarm. ' See structural letter for roof areas that require tighter connection 6'-7" spacing than listed. _ OWNER INSTALLED 3'-3" [POINT LOAD CALCULATION J ITEM #ORLIN WEIGHT~ TOTAL WEIGHT DESIGN CRITERIA _ FT PER(Ibs) (Ibs) 1 " MODULES 22 40.78 897.16 MODULES: 22 RAILS 121.03 0.4 52.8 MAX DISTRIBUTED LOAD:3 PSF 4'0" SNOW LOAD:25 PSF JOSE UMANA ATTACHMENTS 40 0.65 26.00 WIND SPEED: 51750 MAIN RD 5'-6" S-6" TILT LEGS 0 3.5 0 136 MPH 3-SEC GUST. LAG SCREWS: SOUTHOLD NY 11971 ENPHASE INVERTER 22 1.4 30.8 5/16"x 2.5"MIN EMBEDMENT Email:Joseumana06@gmall.com NOTE: Phone:631-830-1484 TOTAL WEIGHT 1006.7 lbs INSTALLERS TO VERIFY RAFTER MODULE DIMENSION(LxW) 65.95 x 39.06= 17.88 sq.ft SIZE,SPACING AND SLOPED REV A ------ - SPANS,AND NOTIFY E.O.R.OF DATE:14 JUNE 2023 I WEIGHT PER MOUNT 1006.7/40= 25.2 Ibs/Mount ANY DISCREPANCIES BEFORE NOTE:-MAX.ATTACHMENT SPACING IS 4'-0" WEIGHT PER SQ FT 1006.7/ 393.36 sq.ft:2.6 Ibs/sq.ft. PROCEEDING. LAYOUT DETAIL (STAGGERED) ------- - - — PV 3.0 ,LVECTOR E n e I n eI E R 8 s.c.rar o,.„c rea„ego-r vie oa�rca,rl.a.r a4p20 mvw.vecmaea.enw PV MODULE s @Za o0 (E)SINGLE 06/15/2023 2X4 ZRus COMPOSITE SHENGLE FR OFirm License Number:081423 VSE Project Number:U2557.0813.221 UNAUTHORIZED ALTERATIONS OR ADDITIONS TO A DOCUMENT BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF SECTION 7209(2)OF THE N.Y. STATE EDUCATION LAW SEE(2/PV-4.0)FOR ENLARGED VIEW veaor sbaswra Engthaeag wa nNewaa tha e.sug ewaoro with loading from the solar array and screw nnectws to the ealshng f ambg,The design of Me m:.g system,..M g connegions,aad a0 of, sbuMnal Is by others.Medmalcel,amhttecluml,and all other nansWCWraI aspects of the doalgn are by others. Elecbkal is by others,Mess stamped by Dean I-mrsen. See structural letter for 1 ATTACHMENT DETAIL roof areas that require PV-4.0 SCALE:1"=1' tighter connection spacing than listed. PV MODULES IRONRIDGE INTEGRATED GROUNDING&END/MID CLAMP IRONRIDGE FLASHVUE ATTACHMENTS IRONRIDGE XR100 RAILOWNER INSTALLED ALUMN."L"BRACKET W/3/8"SS BOLT&NUT E SINGLE LAYER OF COMPOSITE SHINGLE JOSE UMANA IRONRIDGE FLASHVUE 51750 MAIN RD FLASHING 5/16"X4.25"SS LAG SCREW SOUTHOLD NY 11971 WITH MIN 2Y2'THREAD Email:Joseumana06@gmall.com EMBEDMENT,SEALED Phone:631-830-1484 2"X4"TRUSS @ 24"O.C. PENETRATION REV A DATE:14 JUNE 2023 2 ATTACHMENT DETAIL(section view) MOUNTING DETAIL PV-4.0 SCALE:NTS PV 4.0 CONDUIT SCHEDULE GROUND NOTE: ENVOY BREAKER CAN BE 10A OR 15A IN IQ COMBINER BOX, MAIN BREAKER DERATE: b CONDUIT CONDUCTOR NEUTRAL(WHITE) (GREEN) (BARE COPPER) ENPHASE MICRO INVERTERS ARE EQUIPPED WITH RAPID REFER TO TECHNICAL BRIEF IN ATTACHED SPEC SHEETS. REPLACE EXISTING MAIN BREAKER (RED/BLACK) SHUTDOWN FUNCTION PER NEC 690.12. WITH NEW 90 AMP MAIN BREAKER. 1 NONE ENPHASE O-CABLE NONE NONE (1)ff6 (4)10 AWG (1)6 AWG SYSTEM SIZE:704OW DC,5280W AC 2 314'EMT THHN/TFIWN-2 NONE THHNRHWN-2 NONE 3 3/4'EMT (2)8AWG (1)8AWG (1)6 AWG NONE THHN/THWN2 THHN/THWN-2 THHN/THWN-2 3 (N)LOCKABLE EXISTING WIRING BLADE TYPE 3 IQ COMBINER AC DISCONNECT BOX 2 1 2PR- 1 5A* • 90A PHONO SOLAR PS320MH-20/UH (MONITORING) NEW 11 ENPHASE ENERGY INC.IQS-60-2-US[240V] O O (1)CIRCUIT OF(11)MODULES 4 STRING A,ARRAY 1 20A-2P 2P 1 30A SOLAR BREAKER PHONO SOLAR PS320MH-20/UH AT OPPOSITE 1A 2A 3A 20A-2P END OF 11 ENPHASE ENERGY INC.IQ8-60-2-US[240V) � BUSBAR (1)CIRCUIT OF(11)MODULES STRING B,ARRAY 1 NEW 60A AC EXISTING EXISTING METER JUNCTION BOX ENPHASE IQ DISCONNECT MAIN PANEL OVERHEAD UTILITY SERVICE MIN RATED COMBINER BOX, (2-POLE UNFUSED) 100A BUSBAR — NEMA3R 125A RATED END FED (X-IQ-AMI-240-4) INVERTERS RATING TAKE ENPHASE ENERGY INC. IODEL IQ8-60-2-US[240VI IAX INPUT CONDUCTOR SIZING CALCULATIONS :URRENT 15A CURRENT OWNER INSTALLED TAX POWER CIRCUIT CURRENT Imax(690.8(A)) It(690.8(B)(1)) SPECIFIED AMPACITY @ AMBIENT CARRYING COND.OF USE APPLIED kC) 240W DESCRIPTION calc CONDUCTOR 90c TEMP c COND. (690.8(B)(2))calc OM.AC PV SOURCE 11.00A x 1.25= 40A x 0.96(am b.temp.)x0.80 240V CIRCUITA 11.00A 11.00A 1375A #10 THWN-2 40A 31-35 4-6 'OLTAGE (raceway fill)=30.72A TAX AC 1A PV SOURCE 11OOA 11OOA 11.00A x 1.25= #10 THWN-2 40A 3135 46 40A x 0.96(am b.temp.)x0.80 . . :URRENT CIRCUIT B 13.75A - - (raceway fill)=30.72A :EC97% COMBINER BOX 22.00A 22.00A 22.00A x 1.25=27.5A #8 THWN-2 55A 31 35 1� 55A x 0.96(am b.temp.)x1 JOSE UMANA FFICIENCY OUTPUT (raceway fill)=52.8A 51750 MAIN RD MODULE AND ARRAY RATINGS:(22)MODULES) TERMINAL TEMPERATURE RATING CONSIDERATIONS SOUTHOLD NY 11971 SOLAR MODULE RATINGS(STC) CIRCUITA CIRCUIT B TERMINAL TEMP SPECIFIED AMPACITY @ Email:Joseumana06@gmaii.com CIRCUIT DESCRIPTION CURRENT Icont RATING CONDUCTOR TERMNALTEMP. Phone:631-830-1484 TAKE PHONO SOLAR SERIES 1 1 RATING IODEL PS320MH-20/UH PARALLEL 11 11 PV SOURCE CIRCUIT A 11.00A 11.00A x 1.25=13.75A 75C #10 35A REV PV SOURCE CIRCUIT B 11.00A 11.00A x 1.25=13.75A 75C #10 35A DATE:14 JUNE 2023 np 9.69A Imp 11.OA 11.OA COMBINER BOX OUTPUT 22.00A 22.00A x 1.25=27.5A 75C #8 50A 'mp 33.01V Vmp 240V 240V ELECTRICAL Ic 10.13A Isc 11.OA 11.OA VOLTAGE DROP CALCULATIONS 'OC 39.92V Voc 240V 240V CIRCUIT DESCRIPTION LENGTH I Ohms/kFt V CALC Vdrop PV SOURCE CIRCUIT A 5OFt 11.00A 0.9989 240V 50'x 11.00A x 2 x 0.9989/1000'/240V= 0.46 max 320W Pmax 2640W 2640W PV SOURCE CIRCUIT B M,PV 0.9989 240V 50'x 11.00A x 2 x 0.9989/1000'/240V= 0.46% PV 5.0 ;VoGC -0.306% 1 1COMBINER BOX OUTPUT 30Ft 22.00A 0.6282 240V 30'x 22.00A x 2 x 0.6282/1000'/240V= 0.35% INSTALL ON THE UTILITY METER INSTALL ON THE AC DISCONNECT PHOTOVOLTAIC CAUTION: THIS SERVICE METER I I POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH IS ALSO SERVED BY A DISCONNECTS LOCATED AS SHOWN: PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT:22.00A NOMINAL OPERATING AC VOLTAGE: 240V 8 INSTALL ON THE MAIN BREAKER PANEL SUB PANEL PV ARRAY PHOTOVOLTAIC SOLAR (INDOOR) PHOTOVOLTAIC SYSTEM AC DISCONNECT EQUIPPED WITH • • SHUTDOWN 7TERMINALS MAIN SERVICE PANEL WN IC SHOCK"H7AZARD- . ,• IO COMBINER UTILITY METER(TYP.) __ ON THE AND AC DISCONNECT PV ES MAY BE ENERGIZED TO BE INSTALLED IN ACCORDANCE IN THE OPEN POSITION 51750 MAIN RD,SOUTHOLD,NY 11971 WITH SECTION 690.56(C): A CAUTION SOLAR PV SYSTEM SOLAR ELECTRIC SYSTEM CONNECTED EQUIPPED WITH MAIN BREAKER DERATED FOR SOLAR BACKFEED1 RAPID SHUTDOWN MAIN BREAKER NOTTO EXCEED 90A. OWNER INSTALLED INSTALL INSIDE THE MAIN BREAKER PANEL,NEXT TO THE SOLAR BREAKER INSTALL ON THE PV 7POWERSOURCE AC COMBINER BOX TURN RAPID SHUTDOWN SWITCH TO (IF APPLICABLE) THE"OFF'POSITION TO SHUT DOWN PV SYSTEM AND REDUCE JOSE UMANA UT CONNECTION. SHOCK HAZARD IN THE ARRAY 51750 MAIN RD T RELOCATE THIS SOUTHOLD NY 11971 OERCURRENT DEVICE EmaINSTALL EVERY 10 FEET ON EXTERIOR CONDUIT. PHOTOVOLTAIC SYSTEM Phone: :631-30-148@gmail.com Phone:631-830-1484 PHOTOVOLTAIC WARNING: PHOTOVOLTAIC, COMBINER PANEL REVA SOLAR BREAKERPOWER SOURCE DO NOT ADD LOADS DATE:14 JUNE 2023 DO NOT RELOCATE THIS WARNING LABELS OVERCURRENT DEVICE PV 6.0 Phana' salars TwinPIUS Module Mono Perc/310-325W E--PVEL TOPPERFORMER I DNV•GL � Bloomberg Tier RV MODULE NEW ENERGY FINANCE RELIABILITY SCORECARD ' I PID Resistant Better Shading Tolerance More Reliable ® Lower hot spot temperature More Power 4'R Low power loss in cell connection Low temperature coefficient(Pmax):--0.417%/'C Low NOCT:4512°C 100% ®12-year product warranty 25-year linear performance warranty 3 97% 0 CL so^s 0 c ro 2x6o �r 0 5 10 15 20 25 O Industry standard � Phono Solar near Cells [oil,.W 0 _ r SINDMACHISUMEC ❑■ , . EN-20200220 SUMEC GROUP CORPORATION ELECTRICAL TYPICAL VALUES oo- e e e e e e e e e e e e Type Monocrystalline 156.75mm x 78.38mm Rated Power(Pmpp) 31OW 315W 320W 325W Tolerance 0-+5w Rated Current(Impp) 9.51 9.60 9.69 9.78 Rated Voltage(Vmpp) 32.58 32.79 33.01 33.21 Short Circuit Current(Isc) 9.95 10.04 10.13 10.22 Open Circuit Voltage(Voc) 39.58 39.74 39.92 40.10 Module Efficency(%) 18.66 18.96 19.26 19.56 NOCT(Nominal Operation Cell Temperature) 45±2°C Voltage Temperature Coefficient -0.306%/°C Current Temperature Coefficient +0.046%/°C Power Temperature Coefficient -0.417%/°C MECHANICAL�CHARACTERISTICS ELECTRICAL .R •ISTI CS Length:1675mm(65.95 inch) Dimension(Lx W x H) Width:992mm(39.06 inch) 350 Height:35mm(1.38 inch) 30000tJ.5.;260------------------------- ----- ---- -Incident Irrad.=1000W/m2 -Inadent I111tl.=800W/m2 Weight 18.5kg(40.78 lbs) -incident lnad:6o0W1m2 200 -Incident lnad.=400WIm2 - Front Glass 3.2mm Toughened Glass ----ent-----o---- 1s0----------------- -- ---- ------------- -- Frame Anodized Aluminium Alloy n 1t0 --------- 4mm2(IEC) , Length:350mm (vertical) 50 Cable 1150m (horizontal) or Customized Length °° 10 Voltage 040 3° Junction Box IF 68 Rated 12 Cellte .25C ABSOLUTE RATING nt 10.--IndideIriad=1000W'rtlZ_____._____________________ ¢^ 5 -Incident lrrad.-=800W/m2--------------------- ------ Parameterc " d 6---Incident brad.=600W/m2---------------- ----- ----- U Operating Temperature From-40 to+85°C 4-__Incideatlnnad=400WIM2__________________-___- Hail Diameter @ 80km/h Up to 25mm 2 Incidentlrrad.=200Wim2-----. Surface Maximum Load Capacity Up to 5400Pa °° 6 10 IS 20 25 435 4o Maximum Series Fuse Rating 20A PV Module Classification II 95437 56 Module Fire Performance Typel Maximum System Voltage DC 1000V/1500V _ IML PACKI,NG CONFIGURATION 3511 361 Pieces/Container 780 - &6.5X10(0.26%0.391 1.In compliance with our warranty terms and conditions. 2.Measurement conditions under irradiance level of Standard Test Conditions(STC):1000W/m2 992 39.06 Note: (inch) Air mass 1.5 spectrum,cell temperature of 25°C. 101"Or"t" A111111""'11111, C® CE �o �(�° Ery. Tav )s a a r PV dYCLE S �/ Da oSfYk J-rEc c �L us �Q �® C us LISTED Intertek Note:This datasheet is not legally binding. Phono Solar Technology Co., Ltd. !� ®n® ®l a�' reserves the right to adjust specifications without notice.Further information please /� refer to our Website:www.phonosolar.com,E-mail:info@phonosolar.com ENPHASE• It rIilr a ENPHASE m IQ8 Series Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to install is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling Enphasel 'I•� 9- High productivity and reliability • Produce power even when the ,1 r; year limited grid is down warranty • More than one million cumulative Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery.Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules Microgrid-forming CERTIFIED Complies with the latest advanced grid support Connect PV modules quickly and easily to I08 Series Microinverters are UL Listed as Remote automatic updates for IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements IQ8SE-DS-0001-01-EN-US-2022-03-01 IQ8 Series Microinverters INPUT 1ATA(DCI 108-60-2-US1: 1: 1: 1: 1 1: 1: Commonly used module pairings' W 235-350 235-440 260-460 295-500 j 320-540., 295-500+ � I Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 ! 60 j Max DC current'[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration j 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit I OUTPUT DATA IACI 108-60-2-US1: 1: 1: 1: 1 1: 1: Peak output power VA 245 j 300 330 366 384 j 366 i Max continuous output power VA 240 290 325 349 1 380 I 360 Nominal(L-L)voltage/range4 V 240/211-264 208/183-250 ! Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuits 16 13 11 11 10 9 I Total harmonic distortion <5% i Overvoltage class AC port III i AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging I Peak efficiency % 97.5 97.6 ; 97.6 97.6 I 97.6 97.4 i CEC weighted efficiency % 97 97 I 9797.5 97 97 Night-time power consumption mw I 60 MECHANICAL DATA Ambient temperature range -400C to+600C(-40oF to+1400F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 i Enclosure Class II double-insulated,corrosion resistant polymeric enclosure I Environ.category/UV exposure rating NEMA Type 6/outdoor I 1 CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 ' Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)The I08H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility(3)Maximum continuous input DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal if required by the utility.(5) Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-01 Data Sheet Enphase Networking Enphase The Enphase IQ Combiner 4/4C with Enphase IQ Gateway and integrated LTE-M1 cell IQ Combiner 4/4C modem (included only with IQ Combiner 4C) X-IQ-AM1-240-4 consolidates interconnection equipment X-IQ-AM1-240-4C into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre-wired solution for - - residential applications. It offers up to four 2-pole input circuits and Eaton BR series " E"P"ase busbar assembly. 7f Smart SRP Includes IQ Gateway for communication and control !' Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05),included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat - Flexible networking supports Wi-Fi, Ethernet,or cellular •_ • Optional AC receptacle available for PLC bridge i 4 _ Provides production metering and consumption monitoring i Simple 1 Centered mounting brackets support single 1` dal stud mounting • Supports bottom,back and side conduit entry Up to four 2-pole branch circuits for 240 VAC • `• plug-in breakers(not included) X-IQ-AM1-240-4C 80A total PV or storage branch circuits I Reliable Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's 4 _ UL listed X-IQ-AM1-240-4 LISTED 0::! E N P H A S E, To learn more about Enphase offerings,visit enphase.com two Enphase IQ Combiner 4/4C MODEL NUMBER IQ Combiner 4 (X-IQ-AM1-240-4) IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C(X-IQ-A M1-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.51Q.Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05);a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US,Canada;Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in the installation area.)Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan for COMMS-CELLMODEM-M1-06 Ensemble sites CELLMODEM-M1-06-SP-05 4G based LTE-M1 cellular modem with 5-year Sprint data plan CELLMODEM-M1-06-AT-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. BRK-10A-2-240V Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-240V-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support BRK-20A-2P-240V-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support EPLC-01 Power line carrier(communication bridge pair),quantity-one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C 'XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board(PCB)for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating 65A Max.continuous current rating(input from PV/storage) 64A Max.fuse/circuit rating(output) 90A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.total branch circuit breaker rating(input) 80A of distributed generation/95A with IQ Gateway breaker included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers MECHANICAL DATA Dimensions(WxHxD) 37.5 x 49.5 x 16.8 cm(14.75"x 19.5"x 6.63").Height is 21.06"(53.5 cm)with mounting brackets. Weight 7.5 kg(16.5 lbs) Ambient temperature range -40°C to+46°C(-40°to 115°F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors 60 A breaker branch input:4 to 1/0 AWG copper conductors Main lug combined output:10 to 2/0 AWG copper conductors Neutral and ground:14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05,CELLMODEM-M1-06-AT-05(4G based LTE-M1 cellular modem). Notethat an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional,802.3,CatSE(or Cat 6)UTP Ethernet cable (not included) COMPLIANCE Compliance,IQ Combiner UL 1741,CAN/CSA C22.2 No.107.1, 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Consumption metering:accuracy class 2.5 Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 To learn more about Enphase offerings,visit enphase.com u E N P H AS E. @ 2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of Enphase Energy,Inc.Data subject to change.10-21-2021 TECHNICAL BRIEF EN PHASE. 10A and 15A Circuit Breakers for the Enphase AC Combiner Enphase allows you to remove spare circuit breakers and to downsize the combiner breakers within the Enphase AC Combiner Box"'. Overview The Enphase AC Combiner Box- (XAM1-120) is a UL listed.assembly for the purpose of combining circuits and providing monitoring in an Enphase Microinverter system. See our Certificate of Compliance from UL. Some Authorities Having Jurisdiction (AHJs) have inquired about details related to the internal manufacturing of the AC Combiner product. Since the assembly has been evaluated and listed by UL for the applications supported as detailed in the product manual,the internal workings of the AC Combiner box do not require additional evaluation for compliance with the National Electrical Code. As such,the busbar rating and AC circuit breaker fK ratings inside the AC Combiner Box do not require LT additional evaluation.However,Enphase does provide some guidance for modifying the AC Combiner Box circuit breakers for a given application.We allow for and support the removal • of spare circuit breakers,and for downsizing the • Combiner Breakers within the AC Combiner Box. • s - • • 4 Always follow removal instructions and torque ` w requirements from the installation documentation when removing or swapping breakers. • s • Combiner Replacement Breakers breakers We have evaluated the following 15A and 10A circuit breakers for use in the AC Combiner Box. You can order replacement circuit breakers from Safe Circuits at: Safe Circuits 1-800-863-2134 http://www.safecircuits.com/ Specifications Ordering Info Manufacturer Info i I Safe Circuits Part Number CBI Electric Part Number j 10A,2 pole,240V QL29MS10 QL-2(13)-DM-10A 15A,2 pole,240V QL29MS15 QL-2(13)-DM-15A 1 ©2016 Enphase Energy Inc.All rights reserved. July 2016 i lr IRON RIDGE Flush Mount System 777777777, Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty ® Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. �■r XR Rails O XR10 Rail XR100 Rail XR1000 Rail Bonded Splices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish • Clear anodized finish • Forms secure bonding Clamps & Grounding O UFOs Stopper Sleeves Grounding Lugs Microinverter Kits Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount MIs or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled &lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • Sized to match modules • Single tool installation • Kit comes assembled • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 Attachments O FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System with superior waterproofing. attachment. to roof attachments. to various heights. • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options • Works with vent flashing • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • 4"and 7" lengths. • Mill and black finish • Clear and black finish • Assembled and lubricated • Ships assembled — Resources Design Assistant PaNABCEP Certified Training - Go from rough layout to fully Earn free continuing education credits, _ engineered system. For free. NABCEP while learning more about our systems. - Go to IronRidge.com/design Go to IronRidge.com/training 4 �PJ�� .1 ZIA'vk IRON RIDGE UFO Family of Components Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails.All system types that feature the UFO family—Flush Mount,Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. 9 Object UFO Universal Fastenin Stopper Sleeve 1 (UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XR {'^I onto the UFO,converting it into Rails. It comes assembled and lubricated,and a bonded and clamp. can tit a wide range of module heights. Flow- Bonded Splice Each Bonded Splice uses self-drilling screws to form a secure connection.No bonding strap needed. Grounding Lug Asingle Grounding Lug Bonded Attachments low connects an entire row The bonding bolt attaches of PV modules to the and bonds the L-foot to the grounding conductor. rail.It is installed with the same socket as the rest of the system. System Diagram - - - - - - - - - - - - - - - -m- - - - - - - - - - - - - - - - - - - 0 UFO a Stopper Sleeve • Grounding Lug Bonded Splice J- Ground Wire 4 Approved Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for grounding lugs and field installed equipment ground conductors (EGC).A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification Cr m The IronRidge Flush Mount, Tilt Mount, and Ground Mount 7Raiis r XR1000 Only Systems have been listed to UL 2703 by Intertek Group pic. 7 v Ire UL 2703 is the standard for Bonded Splice N/A evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array systems. It ensures these devices Microinverters Enphase- M250-72, M250-60, M215-60,C250-72 will maintain strong electrical and &Power Darton-MIG240, MIG300, G320, G640 mechanical connections over Optimizers SolarEdge- P300, P320, P400, P405, P600, P700, P730 an extended period of time in extreme outdoor environments. Fire Rating Class A Class A N/A FModules Tested or Evaluated with over 400 Framed Modules Go to IronRidge.com/UFO Refer to installation manuals for a detailed list. � � .w1►. IRON RIDGE Class A Fire Rating Background All roofing products are tested and classified for their ability to resist fire. Test Setup Recently, these-fire resistance standards Solar Modules Solar modules are given a Type were expanded to include solar equipment classification based on their as part of the roof system. Specifically, this materials and construction. requires the modules, mounting hardware Mounting System and roof covering to be.tested together asMounting Is tested as part of a system that Includes type-tested a system to ensure they achieve the same modules and fire-rated roof covering. fire rating as the original roof.covering. Roof covering Roof covering products are given a Adoption of these new requirements will Fire Class Rating of A,B or C based begin in California in 2015 and extend to on their tested fire resistance. the rest of the country in 2016. Burning Brand Test IronRidge Certification In August 2014, IronRidge was the first company to receive a Class A Fire Rating— the highest possible rating—from Intertek Group plc.,a Nationally Recognized Testing A burning wooden block Is placed on module as a fan blows at 12 mph. Laboratory. Flame cannot be seen on underside of root within 90 minutes. IronRidge Roof Mount products were tested Spread of Flame Test on flat and sloped roofs in accordance with the new UL 1703&UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Flame at southern edge of roof is aimed up the roof as a fan blows at 12 Rating on your next project:' mph.The flame cannot spread 6 feet or more in 10 minutes. 7S7teeplope(>9.5 deg.) Flush Type 1 &2 Class A Flush Type 1 Class A Low Slope (�9.5 deg.) Tilt FEE Type.1 Class A 'Can be installed on Class A,B,8 C roofs. mm Frequently Asked Questions What is a"module type"? What attachments and flashings are deemed compatible with Class A? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters Attachments and their respective flashings are not and 2 fire performance parameters.The purpose of constituents of the rating at this time.All code-compliant this classification is to certify mounting systems without flashing methods are acceptable from a fire rating needing to test it with every module. standpoint. What roofing materials ane covered? What mounting height is acceptable? All fire rated roofing materials are covered within this The UL testing was performed at a height of 5".The certification including composition shingle, clay and code does not specify minimum or maximum height.The cement tile,metal, and membrane roofs. Iron Ridge Class A rating covers all heights as long as they fit within the"flush mounted"category. What if I have a Class C roof,but the jurisdiction now requires Class A or B? Am I required to install skirting to meet the fire code? Generally,older roofs will be"grandfathered in",and will not require re-roofing.However, if 50%or more of the No, I ronRidge-achieved a Class Afire rating without any roofing material is replaced,for the solar installation the additional racking components. code requirement will be enforced. What determines Fire Classification? Where is the new fire rating requirement code listed? Fire Classification refers to a fire-resistance rating 2012 IBC: 1509.7.2 Fire classification. Rooftop system for roof covering materials based on their ability mounted photovoltaic systems shall have the same fire to withstand fire exposure. classification as the roof assembly required by Section 1505. Class -effective against severe fire exposure Class B-effective against moderate fire exposure Where is a Class A Fire Rating required? Class C-'effective against light fire exposure The general requirement for roofing systems in the IBC What if the roof covering is not Class A rated? refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas(WUI) and The IronRidge Class A rating will not diminish the fire for very high fire severity areas.Many of these areas are rating of the roof,whether Class A,B,or C. found throughout the western United States.California has the most Class A and B roof fire rating requirements, What tilts is the tilt mount system fire rated for? due to wild fire concerns. The tilt mount system is rated for 1 degrees and up and Are standard mid clamps covered? any roof to module gap, or mounting height. Mid clamps and end clamps are considered part of the PV"system", and are covered in the certification. More Resources Fire Rating Certificate Engineering Certification Letters Visit our website to download the official UL We offer complete engineering resources 2703 certification document. and pre-stamped certification letters. Go to IronRidge.com Go to IronRid Xom 02a16 1rcnMdM Ina.AJI rlghtsresma&irigkviwwlronrtd_qe.00m or oafll-&10-22761523 for roore infornmao.M Version 1.110 OAr , AW IRON RIDGE FlashVueT"' ova ng Mashhg Forward We set out to design a flashing that checked all the boxes: fully waterproof, fast and easy to install correctly, economical, and strong enough to handle every environmental condition. FlashVue does it all. The optimized flashing design features a large I� viewport, for easy alignment with the pilot hole.And the GripCap and GripCap+ sit snugly in place, so the lag can be driven single-handedly. Three-Tier Water Seal, Reimagined FlashVue's seal architecture utilizes three layers of protection.The viewport is elevated 0.30",and ie provides a"friction-fit"for the GripCap.The GripCap fully covers the viewport while a sealing washer adds another layer of protection.And an EPDM 1 washer and lag bolt"seal the deal"in the stack. GripCap&GripCap+ The 360°capable GripCap(2.74" tall)and GripCap+(3.74"tall)can be placed in any orientation,and provide'a y "friction-fit"for easy installs. Push snug a _ into the viewport,without worrying'it will \ roll away or rotate while driving the lag. � Qs 0.75„ ONLarge Viewport in Flashing Intertek _ The large viewport makes it easy to 0 _ align the flashing with the pilot hole,and Triple Certified to \ drive the lag centered into the rafter.The Protect the Roof elevated rim not only provides a sturdy UL 2703,441 (27) ° dock for the GripCap or GripCap+,but TAS 100(A)-95 increases water-shedding capabilities. See Your Pilot Holes ,,s-..w.,•,ew'a�fa g.' �&-..,,, „-..} h f f• �`•. �. t= 5.' ^i - - '�. -. _. .,., .�i _ T..—_ IRMO - -.a y r ,�F ��• 1 I 1 `�', 0.75" °'Yv r Solve Roof Undulations RC1"e®. .� ; >>z-•. GVIPCEP V1 LA r GrlpC'sp¢ ---------- ------ -- ®�Uneven Room SuFftees :�119 Trusted Strength & Certification 17Attachment Loading P FlashVue has been tested and rated to support 1161 (Ibs) of uplift and 353 (lbs) of lateral load. Structural Certification Designed and certified for compliance with the International Building Code &ASCE/SEI-7. ® Water Seal Ratings Passed both the UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. ® UL 2703 Listed System Conforms to UL 2703 mechanical and bonding requirements. See Flush Mount Manual for more info. Z7 - N /lr I RON RI DGE FlashVue 1 2 3 4 a ITEM NO DESCRIPTION QTY IN KIT 1 BOLT, LAG 5/16 X 4.25" 1 2 WASHER, EPDM BACKED 1 3 FM FLASHI,NG,_MILL OR BLACK 1 4 GRIP CAP, MILL OR BLACK 1 FLASHVUE PART NUMBER DESCRIPTION FV-01-M1 FLASHING, FLASHFOOT, MILL FV-01-B1 FLASHING, FLASHFOOT, BLACK 1) BOLT, LAG 5/16 x 4.25" 0.61 .26 5/16 THD 4.25 7/16" Head S I I Property Value Material 300 Series Stainless Steel Finish Clear V1.0 2) Washer, EPDM Backed 0.35 Property Value -�— Material 300 Series Stainless Steel 0.75 Finish Clear 3) Grip Cap .40---►I .36 �+ 1.00 i + 2.74 Property Value Material Aluminum Finish Mill/Black 4) FM Flashing 8.0 32 12.0 Property Value Material Aluminum Finish Mill/Black V1.0 8431 Murphy Drive Intertek Middleton,WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Veriicati®n of Conformity In the basis of the tests undertaken,the sample(s)of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name&Address: IronRidge, Inc. 28357 Industrial Blvd Hayward, CA 94545 USA Product Description: Flush Mount System with XR Rails. Ratings&Principle Fire Class Resistance Rating: Characteristics: -Flush Mount(Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2,3, 13, 19,25 and 29 listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1,2 and 3, listed photovoltaic modules. Tested with a 5"gap(distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. This rating is applicable with any IronRidge or 3'rd party roof anchor. Models: IronRidge Flush Mount with XR Rails Brand Name: IronRidge Flush Mount Relevant Standards: UL 2703 (Section 15.2 and 15.3)Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2)Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. Verification Issuing Office: Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton,WI 53562 Date of Tests: 08/27/2014 to 03/17/2015 Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001&101999492MID-001ar1-cr1, 104428358MID-001EEV Revision Summary 8/27/2020 Added type 13, 19,25 and 29 to system, update address. This verification is part of the full test report(s)and should be read in conjunction with them.This report does not automatically imply product certification. Completed by: Chris Zimbrich Reviewed by: Chad Naggs Title: Technician I, Fire Resistance Title: Technical Team Lead, Fire Resistance Signature: Signature: Date: 08/27/2020 Date: 08/27/2020 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Verification.Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material,product,or service is or has ever been under an Intertek certification program. GFT-OP-11a(24-MAR-2014) VECTOR E n G I n E E R S VSE Project Number:U2557.0813.221 June 15,2023 Go Green Solar ATTENTION:Josh Roelofs 1630 S. Sunkist St. Ste.E Anahein,CA 92806 REFERENCE: Jose Umana Garage:51750 Main Road,Southold,NY 11971 Go Green Solar Project:52253 Solar Array Installation To Whom It May Concern: We have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review,we conclude that the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code:2020 Building Code of New York State Risk Category:II Design wind speed,Vult: 128 mph(3-sec gust) Wind exposure category:C Ground snow load,Pg:25 psf Existing Roof Structure Roof structure:2x4 manufactured trusses @ 24"o.c. Roof slope: 18° Connection to Roof Mounting connection:(1)5/16" lag screw w/min.2.5"threaded embedment into framing Maximum mounting spacing along rails: Zone 1,2e(Beyond 3'from roof edge or within T of roof edge perpendicular to slope):48"o.c. Zone 2n,2r,3e(Within 3'of roof edge parallel w/slope,3'of roof ridge,or 3'of eave-eave comer):24"o.c. Zone 3r(Within 3'of ridge-eave comer):24"o.c. Install(2)rails per row of panels,evenly spaced;panel length perpendicular to the rails shall not exceed 65.9 in Rail cantilever shall not exceed 33%of connection spacing Connections shall be staggered so as not to overload any existing structural member Conclusions 651 W.Galena Park Blvd.,Ste. 101/Draper, UT 84020/T(801)990-1775/F(801)990-1776/www.vectorse.com VSE Project Number: U2557.0813.221 Jose Umana Garage yE C T O R 6/15/2023 E fl G I n E E R S Based upon our review,we conclude that the existing structure is adequate to support the proposed solar panel installation. In the area of the solar array, other live loads will not be present or will be greatly reduced (2020 Building Code of New York State, Section 1607.13.5.1). The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 806.3 of the 2020 Existing Building Code of New York State are met and the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 10" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind(uplift), the governing load case. Increases in lateral forces less than 10% are considered acceptable. Thus the existing lateral force resisting system is permitted to remain unaltered. Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contractor must notify Vector Structural Engineering,LLC should any damage, deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables.The design of the solar panels,solar racking(mounts,rails,etc.)and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. Vector Structural Engineering shall be notified of any changes from the approved layout prior to installation. VECTOR STRUCTURAL ENGINEERING,LLC NY Firm License:081423 * �k 06/15/2023 Wells Holmes,P.E. Unauthorized alterations or additions to this letter which bears a NY License: 90187-Expires:09/30/2023 licensed professional engineer's seal is aviolation of Section Project Engineer 7209(2)of the N.Y.State Education Law Enclosures WLH/reh 651 W.Galena Park Blvd.,Ste. 101/Draper, UT 84020/T(801)990-1775/F(801)990-1776/www.vectorse.com JOB NO.: U2557.0813.221 TSUBJECT: WIND PRESSURE E n sin E E R S PROJECT: Jose Umana Garage Com onents and Cladding Wind Calculations Label: Isolar Panel Array Note: Calculations per ASCE 7-16 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 128 Notes: Exposure Category: C Risk Category: II i i ADDITIONAL INPUT&CALCULATIONS: Height of Roof, h [ft]: 15--7(Approximate) Comp/Cladding Location:jGable Roofs 7°<A<20° Enclosure Classification: Enclosed Buildings Zone 1, 2e GCp: 2.00 Figure 30.3-213 Zone 1, 2e Ya: 0.78 Fig. Zone 2n, 2r, 3e GCp: 3.00 (negative coeff.) Zone 2n, 2r, 3e Ya: 0.80 29.4-8 Zone 3r GCp: 3.60 Zone 3r Ya: 0.80 a: 9.5 Table 26.11-1 z9 [ft]: 900 Table 26.11-1 Kh: 0.85 Table 26.10-1 Ke: 1.00 Table 26.9-1 Kn: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 30.2 Equation 26.10-1 YE: 1.50 Section 29.4.4 WIND PRESSURES: Equation 29.4-7 P =q (GCp)(YE)(Ya) Zone 1, 2e, p [psf]: 71.0 psf(1.0 W) Zone 2n, 2r, 3e, p [psf]: 108.9 psf(1.0 W) Zone 3r, p [psf]: 130.6 psf(1.0 W) (a = 3 ft) JOB NO.: U2557.0813.221 TSUBJECT: CONNECTION E rl G I fl E E R S PROJECT: Jose Umana Garage Calculate Uplift Forces on Connection PressureMax Trib. Width z Max Trib. Max Uplift (0.6 Dead -0.6 Wind) Area Force (psf) (ft) (ft) (Ibs) Zone 1, 2e 40.8 4.0 11.0 449 Zone 2n, 2r, 3e 63.5 2.0 5.5 349 Zone 3r 76.6 2.0 5.5 421 Calculate Connection Capacity Lag Screw Size [in]: 5/16 Cd: 1.6 NDS Table 2.3.2 Embedment3 [in]: 2.5 Grade: SPF (G = 0.42) Nominal Capacity[lbs/in]: 205 NDS Table 12.2A Number of Screws: 1 Prying Coefficient: 1.4 Total Capacity [lbs]: 586 Determine Result Maximum Demand [lbs]: 449 Lag Screw Capacity[lbs]:1 586 Result: Capacity> Demand, Connection is adequate. Notes 1. 'Max Trib.Width' is the width along the rails tributary to the connection. 2. 'Max Trib Area' is the product of the 'Max.Trib Width'and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 66". 3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective.The length of the tapered tip is not part of the embedment length. JOB NO.: U2557.0813.221 TO R SUBJECT: GRAVITY LOADS E n O 1 n E E R S PROJECT: Jose Umana Garage GRAVITY LOADS Roof Pitch: 3.9 :12 Design material Increase due to Material weight ROOF DEAD LOAD (D) weight [psf] pitch [psf] Composite Shingles 2.1 1.05 2.0 1/2" Plywood 1.1 1.05 1.0 Framing 3.0 3.0 Insulation 0.5 0.5 1/2" Gypsum Clg. 2.1 1.05 2.0 M, E & Misc 6.5 6.5 Total Existing Roof DL 15.3 PV Array DL 3.2 1.05 3 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf] 20 ASCE 7-16 Table 4.3-1 Roof Live Load With PV Array [psf] 0 2020 Building Code of New York State,Section 1607.13.5.1 SNOW LOAD (S): Existing w/Solar Array Roof Slope [x:12]: 3.9 3.9 Roof Slope [°]: 18 18 Ground Snow Load, pg [psf]: 25 25 ASCE 7-16,Section 7.2 Terrain Category: C C ASCE 7-16,Table 7.3-1 Exposure of Roof: Fully Exposed Fully Exposed ASCE 7-16,Table 7.3-1 Exposure Factor, Ce: 0.9 0.9 ASCE 7-16,Table 7.3-1 Thermal Factor, Ct: 1.1 1.1 ASCE 7-16,Table 7.3-2 Risk Category: 11 II ASCE 7-16,Table 1.5-1 Importance Factor, Is: 1.0 1.0 ASCE 7-16,Table 1.5-2 Flat Roof Snow Load, pf[psf]: 17 17 ASCE 7-16, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]: 0 0 ASCE 7-16,Section 7.3.4 Unobstructed Slippery Surface? No No ASCE 7-16,Section 7.4 Slope Factor Figure: Figure 7-2b Figure 7-2b ASCE 7-16,Section 7.4 Roof Slope Factor, Cs: 1.00 1.00 ASCE 7-16, Figure 7.4-1 Sloped Roof Snow Load, ps [psf]: 17 17 ASCE 7-16, Equation 7.4-1 Design Snow Load, S [psf]: 17 17 JOB NO.: U2557.0813.221 TSUBJECT: LOAD COMPARISON E n G I n E E R S PROJECT: Jose Umana Garage Summary of Loads Existing With PV Array D [psf] 15 18 Lr[psf] 20 0 S [psf] 17 17 Maximum Gravity Loads: Existing With PV Array (D+Lr)/Cd [psf] 28 20 JASCE 7-16,Section 2.4.1 (D+S)/Cd [psf] 28 1 31 ASCE 7-16,Section 2.4.1 (Cd=Load Duration Factor=0.9 for D,1.15 for S,and 1.25 for Lr) Maximum Gravity Load [psfl:1 28 1 31 Maximum Member Forces: GEOMETRY Span(ft) 32.0 (Approximate) Solar Panel Array Start, a (ft) 4.4 (Approximate) Solar Panel Array Length, b(ft) 11.1 (Approximate) Framing Spacing(ft) 2.0 MEMBER FORCES Existing With PV Array Ratio Vertical Reaction,Vl(lbs) 907 949 105OK Vertical Reaction,VZ(lbs) 907 926 10211/1-ElOK Existing With PV Array Ratio Moment.@ Center, M (lbs-ft)[- 7253 7556 104% OK The gravity loads,and thus the stresses of the structural elements,in the area of the solar array are either decreased or increased by no more than 5%.Therefore,the requirements of Section 806.3 of the 2020 Existing Building Code of New York State are met and the structure-is permitted to remain unaltered. T 1 APPROVED AS NOTED OCCUPANCY OR DATEt - a3 B.R.t g o16 USE IS UNLAWFUL BY. WITHOUT CERTIFICATE NOTIFY BUILDING DEPARTMENT AT OF OCCUPANCY 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED. FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. COMPLY WITH ALL CODES OF ALL CONSTRUCTION SHALL MEET THEATE & TOWN CODES REQUIREMENTS OF THE CODES OF NEW NEVA Y®DST AND CONDITIONS OF YORK STATE. NOT RESPONSIBLE FOR AS REQUIRED DESIGN OR CONSTRUCTON ERRORS $QU'HOLD TOWN ZBA SOUTHOLD TOWN PLANNINGBOARD So UTHOLD'TOWN TRUSTEES K N.Y:S..DEO SETAIN STORM WATER RUNOFF 'URSUANT TO CHAPTER 236 ,F THE TOWN CODE, E n G i n E E R s VSE Project Number: U2557.0813.221 September 6,2022 Go Green Solar ATTENTION:Josh Roelofs 1630 S.Sunkist St.Ste.E Anahein,CA 92806 REFERENCE: Jose Umana Garage:51750 Main Road,Southold,NY 11971 Go Green Solar Project:S2253 Solar Array Installation To Whom It May Concern: We have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review,we conclude that the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code:2020 Building Code of New York State Risk Category: U Design wind speed,VuIt: 128 mph(3-sec gust) Wind exposure category: C Ground snow load,Pg:25 psf Existing Roof Structure Roof structure:2x4 manufactured trusses @ 24" o.c. Roof slope: 18° Connection to Roof Mounting connection:(1)5/16"lag screw w/min.2.5"threaded embedment into framing Maximum mounting spacing along rails: Zone 1,2e(Beyond Y from roof edge or within T of roof edge perpendicular to slope):48"o.c.(portrait and landscape) Zone 2n,2r,3e(Within Y of roof edge parallel w/slope,Y of roof ridge,or T of eave-eave corner):24" o.c. (portrait) and 48" o.c. (landscape) Zone 3r(Within Y of ridge-eave corner):24"o.c. (portrait)and 48" o.c.(landscape) Install(2)rails per row of panels,evenly spaced Maximum panel dimension: 70x41 in Rail cantilever shall not exceed 33% of connection spacing Connections shall be staggered so as not to overload any existing structural member 651 W. Galena Park Blvd., Ste. 101/Draper, UT 84020/T(801)990-1775/F (801)990-1776/www.vectorse.com T VSE Project Number: U2557.0813.221 Jose Umana Garage §VL R 9/6/2022 E n G 1 n E E R S Conclusions Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. In the area of the solar array, other live loads will not be present or will be greatly reduced (2020 Building Code of New York State, Section 1607.13.5.1).The glass surface of the solar panels allows for a lower slope factor per ASCE 7,resulting in reduced design snow load on the panels. The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 806.3 of the 2020 Existing Building Code of New York State are met and the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 10" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind(uplift), the governing load case. Increases in lateral forces less than 10% are considered acceptable. Thus the existing lateral force resisting system is permitted to remain unaltered. Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contractor must notify Vector Structural Engineering,LLC should any damage,deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables.The design of the solar panels, solar racking(mounts,rails,etc.)and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. Vector Structural Engineering shall be notified of any changes from the approved layout prior to installation. VECTOR STRUCTURAL ENGINEERING,LLC NY Firm License: COA-081423 � OF,IV�A CV C_ 09/06/2022 Jacob Proctor,P.E. Unauthorized alterations or additions to this letter wlrich bears a NY License: 102527-Expires:01/31/2023 licensed professional engineer's seal is a violation of Section Project Engineer 7209(2)of the N.Y.State Education Law Enclosures JSP/reh 651 W.Galena Park Blvd.,Ste. 101/Draper, UT 84020/T(801)990-1775/F(801)990-1776/www.vectorse.com t JOB NO.: U2557.0813.221 TR SUBJECT: WIND PRESSURE e n rm i n e E R s PROJECT: Jose Umana Garage Com onents and Cladding Wind Calculations Label: IS61ar Panel Array,'.. 777771 Note: Calculations per ASCE 7-16 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 128 Notes: Exposure Category: C Risk Category: II ADDITIONAL INPUT& CALCULATIONS: Height of Roof, h [ft]: c 15n~�2(Approximate) Comp/Cladding Location:'; ble Roofs 70:< Enclosure Classification:'Endmed Bu.ldings-' i _ Zone 1, 2e GCp: 2.00 � 'Figure 30.3-2B ~�~-� Zone^1, 2e Ya 0:77 ;Fig. Zone 2n, 2r, 3e GCp: 3:00 (negative coeff.) Zone 2n, 2r, 3e Ya:"�. ,0:80 j 29.4-8 Zone 3r GCp: 3.60 ,-, ;! Zone 3r Ya:f`.K 0:80- =; a: 9.5 Table 26.11-1 z9 [ft]: 900 Table 26.11-1 Kh: 0.85 Table 26.10-1 Ke: 1.00 Table 26.9-1 Kn: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 30.2 Equation 26.10-1 7E:` 1.50 Section 29.4.4 WIND PRESSURES: Equation 29.4-7 p = gh(GCp)(yE)(ya) Zone 1, 2e, p [psf]: 70.1 psf (1.0 W) Zone 2n, 2r, 3e, p [psf]: 108.9 psf (1.0 W) Zone 3r, p [psf]: 130.6 psf (1.0 W) (a= 3 ft) JOB NO.: U2557.0813.221 TR SUBJECT: CONNECTION E n G I n E E R S PROJECT: Jose Umana Garage Calculate Uplift Forces on Connection PressureMax Trib. Width z Max Trib. Max Uplift (0.6 Dead -0.6 Wind) Area Force (psf) (ft) (ft2} (Ibs) Zone 1, 2e 40.2 4.0 11.7 470 Zone 2n, 2r, 3e 63.5 2.0.. ,, 5.8 370 Zone 3r 76.6 2.0 5.8 447 Calculate Connection Capacity Lag Screw Size[in]: -`'5/16 Cd: 1.6 NDS Table 2.3.2 Embedment3[in]: Grade: SPF (G-= 0.42) Nominal Capacity[lbs/in]: .. 205 NDS Table 12.2A Number of Screws: 1 Prying Coefficient: 1.4 Total Capacity [lbs]: 586 Determine Result Maximum Demand [lbs]: 470 Lag Screw Capacity [lbs]: 586 Result: Capacity> Demand, Connection is adequate. Notes 1. 'Max Trib.Width' is the width along the rails tributary to the connection. 2. 'Max Trib Area' is the product of the'Max.Trib Width' and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 70". 3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective.The length of the tapered tip is not part of the embedment length. JOB NO.: U2557.0813.221 TR SUBJECT: GRAVITY LOADS yEE n s i n E E R S PROJECT: Jose Umana Garage GRAVITY LOADS Roof Pitch: 3.9- :12 Design material Increase due to Material weight ROOF DEAD LOAD (D) weight [psf] pitch [psf] Composite Shingles 2.1 1.05 2.0 1/2" Plywood 1.1 1.05 1.0 Framing 3.0 3.0 Insulation 0.5 0.5 1/2" Gypsum Clg. 2.1 1.05 2.0 M, E & Misc 6.5 6.5 Total Existing Roof DL 15.3 PV Array DL 3.2 1.05 3 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf] 20 ASCE 7-16 Table 4.3-1 Roof Live Load With PV Array[psf] 0 2020 Building Code of New York State,Section 1607.13.5.1 SNOW LOAD (S): Existing w/ Solar Array Roof Slope [x:12]: 3.9 19 . Roof Slope [°]: 18 18 Ground Snow Load, p9 [psf]: 25 25 ASCE 7-16,Section 7.2 Terrain Category: C. C� ASCE 7-16,Table 7.3-1 Exposure of Roof: Full ..Ex used Fully-Exposed ASCE 7-16,Table 7.3-1 Exposure Factor, Ce: 0.9 0.9 ASCE 7-16,Table 7.3-1 Thermal Factor, Ct: 1.1 1.1 ASCE 7-16,Table 7.3-2 Risk Category: II II ASCE 7-16,Table 1.5-1 Importance Factor, Is: 1.0 1.0 ASCE 7-16,Table 1.5-2 Flat Roof Snow Load, pf[psf]: 17 17 ASCE 7-16, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]: 0 0 ASCE 7-16,Section 7.3.4 Unobstructed Slippery Surface? No, Yes .. ASCE 7-16, Section 7.4 Slope Factor Figure: Figure 7-2b Figure 7-2b ASCE 7-16, Section 7.4 Roof Slope Factor, CS: 1.00 0.87 ASCE 7-16, Figure 7.4-1 Sloped Roof Snow Load, ps [psf]: 17 15 ASCE 7-16, Equation 7.4-1 Design Snow Load, S [psf]: 17 15 JOB NO.: U2557.0813.221 SUBJECT: LOAD COMPARISON E n G i n E E R S PROJECT: Jose Umana Garage Summary of Loads Existing With PV Array D[psu 15 18 Lr[psf] 20 0 S [psf] 17 15 Maximum Gravity Loads: Existing With PV Array (D+Lr)/Cd [psf]1 28 20 JASCE 7-16,Section 2.4.1 (D+S)/Cd [psf]1 28 29 IASCE 7-16,Section 2.4.1 (Cd=Load Duration Factor=0.9 for D,1.15 for S,and 1.25 for Lr) Maximum Gravity Load[psf]:1 28 29 Ratio Proposed Loading to Current Loading: 103% 10K The gravity loads,and thus the stresses of the structural elements,in the area of the solar array are either decreased or increased by no more than 5%.Therefore,the requirements of Section 806.3 of the 2020 Existing Building Code of New York State are met and the structure is permitted to remain unaltered. Twinplu,rml Module Mono Perc/310-325W �101/9 TOP PERFORMEfl �• '� I ONV•GL Bloomberg TIer1NEW ANCE RELIABILITYSCORECARD 1 I PID Resistant - Better Shading Tolerance More Reliable Lower hot spot temperature More Power Low power loss in cell connection Low temperature coefficient(Pmax):--0,417%/°C Low NOCT:45±2°C lid ®12-year pmdltctwarranty ®25-year linear performance vtarranzy 979 0 `m 70% '.. 0 10 15 ..20 25 �` D Industry standard Phonc Solar Year 4- ^ 10LVA NO I A51NGMACH ISl�MEC:■ EN-20200220 SUMEC CROUP CORPORATION ELECTRICAL • aVALUES ! i ! ! PS325M—WUH Model ! ! i # ! ! Type Monocrystalline 156.75mm x 78.38mm Rated Power(Pmpp) 31 OW 315W 3201N 325W " Tolerance 0-+5w Rated Current(Impp) 9.51 9.60 9.69 9.78 Rated Voltage(Vmpp) 32.58 32.79 33.01 33.21 Short Circuit Current(Isc) 9:95 10.04 10.13 10.22 . Open Circuit Voltage(Voc) 39.58 39.74 39,92 40.10 Module Efficency(%) 18.66 18.96 19.26 19,56 NOCT(Nominal Operation Cell Temperature) 45±21C Voltage Temperature Coefficient 0.3060Q'C Current Temperature Coefficient +0.046%M Power Temperature Coefficient -0.417%fC CHARACTERELECTRICAL CHARACTER Length:1675mm(65.95 inch) Dimension(Lx W x H) Width:992mm'(39.06.inch) 3i0 Height:35mm(1.38 inch) Ircder5 orad-100CWm-2 —IrcidMc drad.�Nlm'- Weight 18.5kg(40.78 lbs) _u Gee toad,-Www 3- ft..d&t diad.=dOC4tlrtn= Front Glass 3.2mm Toughened Glass Frame Anodized Aluminium Alloy z too 4mm2(IEC), Length:350mm (vertical) Cable 11 50m (horizontal) or Customized Length °° 10 za o Vb`-g-,M Junction Box IP 68 Rated '0 Je-de brad-1030W,119 ABSOLUTEMAXIMUMRATING _ e InciderR trt2d-800W1m: Woes 2 Parameter -°� 5 Ir�CCEid dead.=�WhN Operating Temperature From-40 t6.+85dC O ; . - dr�1u bltd.-'�OIgrtIR Hail Diameter @ 80kmlh Up to 25mm z Surface Maximum Load Capacity Up to 5400Pa °i 5 10 15 —5 ao 35 .3 Maximum Series Fuse Rating 20A 9 (37.561 PV Module Classification D Module Fire Performance Typel Maximum System Voltage DC 1000Vl,1506V s •a +t Container ! Ho ! 351I.381 Pieces/Contairier 780 - e _ scszld lazaxa;»I — — R 1.In compliance with our warranty terms and conditions. P.Measurement conditions under irradiance level of Standard Test Condidons(STC):1000W/m2 Air mass 1.5 spectrum,cell temperature of 25°C. M]WA °a.m.°r PV dY LE SI' ♦♦ 016- 0 w" �Y' EC 6 �L us e n c us LWEU I°IM1eFt Note:This datasheet is not legally binding. Phono Solar Technology Co.. Ltd. Ph®no® ®lar- reserves the right to adjust specifications without notice.Further information please refer to our Website:www.phonosolarcom,E-mail.info@phonosolar.com ENPHASE, m - IQ8 Series Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC Easy to install power to AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling En hase High productivity and reliability y r Produce power even when the iyear t.rnjied grid is down wafairity p. _e More than one million cumulative Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class 11 double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules 0 Microgrid-forming CERTIFIED Complies with the latest advanced grid support Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements IQ8SE-DS-0001-01-EN-US-2022-03-01 IQ8 Series Microinverters INPUT DATA IDNt' .t 0:' e; 11088-240�72-2-US 10811-208-72-2461 Commonly used module pairings= W 235-350 235-440 260-460 295-500 320-540+ 295-500- Module 95-500+Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell.66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC currem3[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal(L-L)voltage/range' V 240/211-264 208/183-250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20A(L-L)branch circuits 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port Ill AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency % 97 97 97 97.5 97 97 Night-time power consumption mw 50 MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection.-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when Installed according to manufacturer's instructions. (1)The 1O8H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility(3)Maximum continuous input DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal if required by the utility.(5) Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 1O8SE-DS-0001-01-EN-US-2022-03-01 Data Sheet Enphase Networking Enphase The Enphase 1Q Combiner 4l4C with Enphase IQ Gateway and integrated LTE-Ml cell IQ Combiner modem (included only with IQ Combiner 4C) X-IQ-AMl-240-4 consolidates interconnection equipment X-IQ-AM1-240-4C into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre-wired solution:for �._ residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart ' Includes IQ Gateway for communication and control Includes Enphase Mobile Connect cellular modem (CELLMODEM-MI-06-SP-05),included only with 1Q ~ Combiner 4C Includes solar shield to match Enphase IQ Battery • aesthetics and deflect heat Flexible networking supports wi-Fi, t Ethernet,or cellular • Optional AC receptacle available for PLC bridge Provides production metering and consumption monitoring Simple k- • Centered mounting brackets support single stud mounting t. Supports bottom,back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers(not included) X IQ-AM1-240-4C 80A total PV or storage branch circuits is Reliable Durable NRTL certified NEMA type 313 enclosure Five-year limited warranty Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed i X-IQ-AM1-240-4 LISTED E N P H A S E. To learn more about Enphase offerings,visit enphase.com a� Enphase IQ Combiner 4/4C, MODEL NUMBER _ €Q Combines 4 (X-€Q-AMI-240-4) �^ IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C(X-IQ-AM1-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05),a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in the installation area.)Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-M1;06-SP-05 with 5-year Sprint data plan'foi _ COMMS-CELLMODEM-Ml-06 Ensemble sites ' CELLMOD£M-Mt-06-SP-05 -4G based LTE-Ml cellular modem with 5-year Sprint data pian CELLMODEM-M1-06-AT-05 -4G based LTE-M1 cellular modem with 5-yearAT&T data plan Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers, BRK-IDA-2-240V Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-240V-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support BRK-20A-2P-240V-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support EPLC-07 Power tine carrier(communication bridge pair),quantity-one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier In IQ Combiner 4/4C(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board(PCB)for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating �� Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating 65A Max.continuous current rating(input from PV/storage) 64A Max.fuse/circuit rating(output) 90A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.total branch circuit breaker rating(input) 80A of distributed generation/95A with IQ Gateway breaker included Production metering CT 200 A,solid core pre-installed and wired to IQ Gateway Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers MECHANICAL DATA Dimensions(WxHxD) Y 37.5 x 49.5 x-16.8 cm(14.75'x 19.5"x 6.63").Height is 21,06°(53-5 cm)with mounting brackets. Weight 7.5 kg(16.5 lbs) Ambient temperature range -40°C to+46°C(400 to 115°F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-cerUfred,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors 60 A breaker branch input:4 to 1/0 AWG copper conductors Main lug combined output:10 to 2/0 AWG copper conductors Neutral and ground:14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 200.0 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n � _ Cellular CELLMODEM-Ml-06-SP-05,CELLMODEM-M1-06-AT-05(4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) COMPLIANCE Compliance,IQ Combiner UL 1741,CAN/CSA C22.2 No.107.1,�47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Consumption metering:accuracy class 2.5 Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 ENPHA To learn more about Enphase offerings,visit enphase.com Nh-#` S E' J 2021 Enphase Energy.All rights reserved Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of Enphase Energy,Inc.Data subject to change.10-21-2021 TECHNICAL BRIEF ENPHASE. 1 QA and 15A Circuit Breakers for the Enphase AC Combiner Enphase allows you to remove spare circuit breakers and to downsize the combiner breakers within the Enphase AC Combiner Box". Overview The Enphase AC Combiner Box' (XAM1-120) is a UL listed assembly for the purpose of combining circuits and providing monitoring in an Enphase Microinverter system.See our Certificate of Compliance from UL. Some Authorities Having Jurisdiction(AHJs) have inquired about details related to the internal manufacturing of the AC Combiner product. Since the assembly has been evaluated and listed by UL for the applications supported as detailed in the product manual,the internal workings of the AC Combiner box do not require additional evaluation for compliance with the National Electrical Code. As such,the busbar rating and AC circuit breaker ° ratings inside the AC Combiner Box do not require additional evaluation. However,Enphase does provide some guidance for modifying the AC Combiner Box circuit breakers for a given application.We allow for and support the removal • of spare circuit breakers,and for downsizing the • Combiner Breakers within the AC Combiner Box. !, __y.v, • • b Always follow removal instructions and torque • ` . • requirements from the installation documentation 6 when removing or swapping breakers. € • _ • Combiner Replacement Breakers breakers We have evaluated the following 15A and 10A circuit breakers for use in the AC Combiner Box. You can order replacement circuit breakers from — - -- Safe Circuits at: Safe Circuits 1-800-863-2134 htto://www.safecircuits.com/ Specifications Ordering.info Manufacturer Info, Safe Circuits Part Number CBI Electric Part Number 10A,2 pole,240V QL29MS10 QL-2(13)-DM-10A 15A,2 pole,240V QL29MS15 QL-2(13)-DM-15A 1 ©2016 Enphase Energy Inc. All rights reserved. July 2016 AftFlush Mount System Bunk for solal's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified,code compliant and backed by a 20-year warranty. ` Strength Tested PE Certified ' All components evaluated for superior : Pre-stamped engineering letters structural performance. available in most states. '. Class A Fire Rating tiy" ";$ Design Assistant �. Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. - _ create, share, and price projects. 3 .-•" UL 2703 Listed System 20-Year Warranty Entire system and components meet k;, Twice the protection offered by t~ newest effective UL 2703 standard. competitors. _ XR Rails XR10 Rail XR100 Rail XR1000 Rail Bonded Splices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish Clear anodized finish - Forms secure bonding Cia reps & Grounding 7 UFOs Stopper Sleeves Grounding Lugs Microinverter Kits Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount MIs or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled & lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size . Sized to match modules • Single tool installation • Kit comes assembled • Clear and black finish • Clear and black finish • Mounts in any direction - Listed to UL 2703 Attachments E) FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs `.-..-'". ;`tt.••tie ..Y a `^'.�.�_ � -_.--._- — ye<��. Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System with superior waterproofing. attachment. to roof attachments. to various heights. • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options Works with vent flashing • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket 4" and 7" lengths • Mill and black finish • Clear and black finish • Assembled and lubricated Ships assembled Resources I Design Assistant j soPo� NABCEP Certified Training _ Go from rough layout to fullyI ��$ Earn free continuing education credits, t � ,r,�1aBC� _ engineered system. For free. while learning more about our systems. i Go to fronRidge,con;ldesign Go to froriRidge.corn/training `End"` ..',��iii ,,'! • - 44, z 'i= , a a:r." Iir7� ,1�:�a f�iM ryn t w* 1 �,y��r �t 1�• Ial e2 �^ �l� � - i a �'� 7 P a 'v y` .a fs IRONRIDGE UFO Family of Components Simplilied Grounding for Ever- App. pfica- n The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to lronRidge XR Rails.All system types that feature the UFO family—Flush Mount,Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system.This leads to safer and more reliable installations. :4, Stopper Sleeve Universal Fastening Object(UFO) The UFO securely bonds solar modules to XR The Stopper Sleeve snaps onto the UFO,converting it into X. Rails. It comes assembled and lubricated,and " a bonded end damp. can fit a wide range of module heights. ----- ----- K, %%. Dullued Splice Z Each Bonded Splice uses sell-drilling screws to form a secure connection.No bonding strap needed. A Grounding Lug A single Grounding Lug Bonded Attachments Va6iw'� connects an entire row The bonding bolt attaches of PV modules to the and bonds the L-foot to the grounding conductor. rail.It is Installed with the same socket as the rest of the system. System Diagram - -- - - - - --- - - - - - - = - - - -: r - - - - - - - - - - - -ECJ- - - - - -- - - - - - -.- - # O UFO C Stopper Sleeve • Grounding Lug [J] Bonded Splice Ground Wire Q Approved Enphase microinverters can provide equipment grounding of Iron Ridge systems,eliminating the need for grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification eE >•,>1��:<d;,-��aa;�:�: "'i,�d t441hSt>"i�'r9�A o�%;_4f a'sg.�'�`,�:f`.a:s�#:`;` '�"�`.'�" � The IronRidge Flush Mount, ... t: + r _ Tilt Mount, and Ground Mount XR Rails _ % XR1000 Only . Systems have been listed to UL 2703 by Intertek Group pic. UFO/Stopper V, r UL 2703 is the standard for Bonded Splice r d N/A evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array t systems. it ensures these devices --� Microinverters Enphase-M250-72, M250-60, M215-60,C250-72 { will maintain strong electrical and &Power Darton-MIG240, MIG300, G320, G640 t mechanical connections over Optimizers =i SolarEdgeP300, P320, P400, P405, P600, P700, P730 an extended period of time in extreme outdoor environments. Fire Rating l Class A Class AN/A I Tested or Evaluated with over 400 Framed Modules uo to arort ,idge.:.oIr licit �Y Modules Refer to installation manuals for a detailed list. .� _ ',1 __ r�rA.=:r.:,f; ,_i,_v� .. -''l C.0,.•?•.: .- ..-7777/0' ,.. , - - . . AMIL URONRKDGE Class A Fire Rating Backgmund All roofing products are tested and classified for their ability toresist fire. Test Setup Solar Modulez- ReoenUy, theomfimameoistmnceatondordo Solar modules are given a Type were expanded toinclude solar equipment classification based on tWr aopart ofthe roof system-Specifically,this materia6-and construction. requires the modules, mounting hardware Mounting System Mounting is tested as part of a and roof covering tobetested together an system that includes type-tested asystem tmensure they achieve the same modules and fire-rated root covering. fire rating aathe original roof covering. Root Covering Root covering products are given a Adoption mfthese new requirements will Fire Class Rating of A,B or C based begin in California in 2015 and extend to on their tested fire resistance. the rest oYthe country in2OiG. Burning Brand Test IKonRidgeCertification /nAugust 2O14. |uonR(dgewas the first company toreceive aClass/\Fire Rating -- the highest possible rating—from |ntertok Group p|o, aNationally Recognized Testing A burning wooden block is placed on modde as a fan blows at 12 mph. Laboratory. Fftune canno!be seen on underside of roof within 90 minutes. (mnRidgeRoof Mount products were tested Spread of Flame Test onflat and sloped roofs inaccordance with the new UL17O3@UL27O3test standards. The testing evaluated the system's ability to resist flame opnaad, burning material and structural damage tothe roof. Refer Uothe table below todetermine the requirements for achieving aClass AFire Rame at southern edge of roof is aimed up the roof as a fan blows at 12 Rating onyour next project. mph.The flame cannot spread 6 feet or more in 10 minutes. r0.+mYj»��eteZti 3 Frequently Asked Questions What is a"module type"? What attachments and flashings are deemed compatible with Class A? The new UL1703 standard introduces the concept of a PV module type,based on 4 construction parameters Attachments and their respective flashings are not and 2 fire performance parameters.The purpose of constituents of the rating at this time.All code-compliant this classification is to certify mounting systems without flashing methods are acceptable from a fire rating needing to test it with every module. standpoint. What roofing materials are covered? What mounting height is acceptable? All fire rated roofing materials are covered within this The UL testing was performed at a height of 5".The certification including composition shingle,clay and code does not specify minimum or maximum height.The cement tile,metal, and membrane roofs. IronRidge Class A rating covers all heights as long as they fit within the"flush mounted"category. What if I have a Class C roof,but the jurisdiction now requires Class A or B? Am 1 required to install skirting to meet the fire code? Generally,older roofs will be"grandfathered in",and will not require re-roofing-However, if 500%or more of the No, lronRidge achieved a Class Afire rating without any roofing material is replaced for the solar installation the additional racking components. code requirement will be enforced. What determines Fire Classification? Where is the new fire rating requirement code lister(? Fire Classification refers to a fire-resistance rating 2012 IBC: 1509.7.2 Fire classification. Rooftop system for roof covering materials based on their ability mourned photovoltaic systems shall have the same fire to withstand fire exposure. classification as the roof assembly required by Section 1505. Class A-effective against severe fire exposure Class 6-effective against moderate fire exposure Where is a Class A Fire Rating required? Class C-effective against light fire exposure The general requirement for roofing systems in the IBC What if the roof covering is not Class A rated? refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas(WUI) and The IronRidge Class A rating will not diminish the fire for very high fire severity areas.Many of these areas are rating of the roof,whether Class A,B,or C. found throughout the western United States.California has the most Class A and B roof fire rating requirements, What tilts is the tilt mount system fire rated forl due to wild fire concerns. The tilt mount system is rated for 1 degrees and up and Are standard mid clamps covered? any roof to module gap, or mounting height. Mid clamps and end clamps are considered part of the PV"system", and are covered in the certification. Mom Res.oullze�s Fire Rating Certificate "�, }. Engineering Certification Letters Visit our website to download the official UL ,` v-)\ F We offer complete engineering resources �i2703 certification document. i �. ; and pre-stamped certification letters. Go,to{ron¢tidge.com GoJq lronfirdge,com 1.�, _•'fil-+l..g';s s"F : c-�::t5(3J" "a �:':E: :' ;'E',7•'.kt", r'S:c; s,..<i�:.iso!'p',s�,.":1:.wx;i>"E<;,.:-::';i a::'t;i { .b.. ., .... .1— ✓,/e'.f....z_,f____-- \'.'a"'. - .b LLJ'k X IRON RIDGE FlashVue T'" Moving Mashing Forward y We set out to design a flashing that checked all the boxes: fully waterproof, fast and easy to install — correctly, economical, and strong enough to handle every environmental condition. FlashVue does it all. WOW The optimized flashing design features a large` viewport, for easy alignment with the pilot hole. And the GripCap and GripCap+ sit snugly in place, so the lag can be driven single-handedly. `y -'=II 17 I Three-Tier Water Seal, Reimagined }} ,. FlashVue's seal architecture utilizes three layers 1 ' C of protection.The viewport is elevated 0.30",and provides a"friction-fit"for the GripCap.The GripCap fully covers the viewport while a sealing washer adds another layer of protection.And an EPDM —_—�— washer and lag bolt"seal the deal"in the stack. GripCap&GripCap+ The 360°capable GripCap(2.74" _,=�^+-�_ '� � _ '=`���.��- �••.�;.� • tall)and GripCap+(3.74"tall)can be ( ° placed in any orientation,and provide'a t % 'friction-fif'for easy installs.Push snug into the viewport,without worrying-it will ` roll away or rotate while driving-the lag. 00.7 Large Newport in Flashing Intertek \ � 1 The large viewport makes it easy to _ _ align the flashing with the pilot hole,and Triple Certified to ,� .w .� o --.yam; ,.� drive the lag centered into the rafter.The Protect the Roof— r elevated rim not only provides a sturdy UL 2703,441 (27) -` dock for the GripCap or GripCap+,but TAS 100(A)-95 increases water-shedding capabilities. Ly See Your Pilot Holes A7 "4 p.�'�:X�`.:P:}•> ,t 9.:1:e �',":�.4i.'Ttr,r!„p..L�'�` _ , .. j({ �yp ( .5,�=i1;°t l t��-aY.-.�R .la<�P.��A°�';f o"m ffa� .t'•� - V��".:. ! tit...� t''r!�5'w;c ,':,ri"'��x"';:�:' ,t, q t ��^^�.+y+''",:..: ,,,�r,• ..';. lE.ry '; .� j'�'f MAW= Solve Roof Undulations t'�1r1�f1�t;S�.Li1 x€°�,•� �t7� $et zi55Y: .;'• - .i . ] ".+," ""w`"•'�",'� .fir...,,-r-..;.. 4 i{_.,�vw.:...:__».•__-_r..._ti.»...-,...s».._..et..z.......--.....ter _ __ ... ........... _ ., _ of Trusted Strength & Certification Attachment Loading FlashVue has been tested and rated to support 1161 (lbs) of uplift and 353 (lbs) of lateral load. Structural Certification L:�.�; Designed and certified for compliance with the international Building Code &ASCE/SEI-7. Water Seal Ratings L Passed both the UL 441 Section 27 "Rain Test' and TAS 100-95 "Wind Driven Rain Test" by Intertek. UL 2703 Listed System `0 L...._._ Conforms to UL 2703 mechanical and bonding requirements. See Flush Mount Manual for more info. ��.�...,�_`�� ��,_ res',:a.�--rte � ._.,�.�. f Rv.tl:�t,-,',-!, .____.�j'-r_..u,r,_...,�'_1. �.,..,,�,..�.._,.�....... Yr x i' • r`���"' �`�� .-:-�s.Jdr��'.�1tJ� 1 I., '1C4.�] .+.'ti :�:i„'4.L:.��t,a,-uHC�:z'YC;.�°'�,'��ez�T..u"'G�`�1�t:��.±r+..::�r-k..it_"-,.(kiir;Y�:�i_rt•RnR; itti�al.34-rtsz�aF i e ,. IRONRIDGE FlashVue 1 2 3 4 d ITEM NO DESCRIPTION QTY IN KIT 1 BOLT, LAG 5/16 X 4.25" 1 2 WASHER, EPDM BACKED 1 3 FM FLASHING, MILL OR BLACK 1 4 GRIP CAP, MILL OR BLACK 1 FLASHVUE PART NUMBER DESCRIPTION FV-01-M1 FLASHING, FLASHFOOT, MILL FV-01-B1 FLASHING, FLASHFOOT, BLACK 1) BOLT, LAG 5/16 x 4.25" 0.61 .26- � 5/16 THD + E I� 4.25 7/16"Head P I - Property Value Material 300 Series Stainless Steel Finish Clear V1.0 .�yi�:�,'�;?+ �.��1�<��4'�5�`x:�a��yr; X'+^�.. `'��V.'4 �y "i' .`�.• a{ ?1,,� ��; ��iMY:±,g �, ";.. 'z J�: 8431 Murphy Drive Middleton,WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com e. t Verification of Conformlt,,j, In the basis of the tests undertaken,the sample(s)of the below product have been found to comply with the requirements of the referenced specifications at the time thetests were carried out: Applicant Name&'Address: IronRidge, Inc. . .28357 Industrial Blvd .2,8357 Industrial 94545 V. USA Product Description: -Flush Mount System with XR Rails. Ratings&Principle Fire Class Resistance Rating: Characteristics: -Flush Mount'(Symmetrical). Class A Fire Rated for Low Slope applications when using-.Type 1, 2,3,13;19,25 and 29 listed photovoltaic,modules. Class A Fire Rated for Steep Slope. applications with Typel,2 and 3, listed photovoltaic modules. Tested with a 5"gap(distance between the bottom,the module frame and the roof covering),per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. This rating is,applicable with any IronRidge or 3'rd party roof anchor. Models: IronRidge Flush Mount with XR.Rails.., Brand Name: IronRidge Flush Mount Relevant Standards: UL 2703 (Section 15.2 and 15.3)Standard for Safety Mounting,Systems, Mounting Devices, Clamping/Retention.Devices,and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels,First Edition dated Jan.28,2015 Referencing UL1703 Third Edition dated Nov. 18, 2014,(Section 31.2)Standard for Safety for Flat-Plate Photovoltaic.Modules and Panels. Verification Issuing Office: Intertek Testing Services NA,Inc. 8431 Murphy Drive _Middleton,WI 53562 Date of Tests:' 08/27/2014 to.03/1.7/2015 Test Report Number(s): 101769343MID-001r1,101769343MID-001a,101915978MID-001&101999492MID-001ar1-cr1,, 104428358MID-001 EEV Revision Summary 8/27/2020 Added type 13, 19,25 and 29 to system, update address. This verification is part of the full test report(s)and should be read in conjunction with them.This report does not automatically imply product certification: Completed by: Chris Zimbrich . Reviewed by: Chad Naggs Title: Technician I, Fire Resistance Title: Technical Team Lead,Fire Resistance Signature: Signature:'.. Date: 08/27/2020 Date: 08/27/2020 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability ore limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Verification.Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material,product,or service is or has ever been under on Intertek certification program. GFT-OP-11a(24-MAR-2014) SCOPE OF WORK GENERAL NOTES TABLE OF CONTENTS SYSTEM SIZE:9280W DC 696OW AC PAGE # DESCRIPTION MODULES:(29)PHONO SOLAR PS320MH-20/UH 0LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY PV 1.0 COVER SHEET INVERTER(S):(29)ENPHASE IQ8-60-2-US MICROINVERTERS SOLAR PHOTOVOLTAIC INSTALLATION RACKING:IRONRIDGE XR100 • THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES PV 2.0 SITE PLAN ATTACHMENT:IRONRIDGE FLASHVUE 0PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED • ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE PV 3.0 DETAIL LAYOUT OCCUPANCY: PRIMARY RESIDENCE UNDERSIGNED PV 4.0 MOUNTING DETAIL CONSTRUCTION TYPE:RESIDENTIAL • ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 • 'ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH PV 5.0 ELECTRICAL DIAGRAM AS GeoCel 2300 CLEAR SEALANT This approval is for compliance to the current adopted building codes for the proposed 0 THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL PV 6.0 WARNING LABELS Solar System only. It is the owner's/applicant's responsibility to ensure that the proposed JURISDICTION AND THE UTILITY IS OBTAINED installation of solar systems and associated equipment is on legally permitted structures. • THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, If determined by inspection staff the proposed solar system is installed on non-permitted MECHANICAL,OR BUILDING ROOF VENTS V E CTO R structures,any required modifications needed for code compliance will be at the IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS owner s/applicant's expense THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE E n o I n E E R s •' EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED 651 W.GALENA PARK BLVD.STE. 101 PHONE(HO i)990-1775 CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION DRAPER,UTAH 04020 WWW.V£CMRSE.CDN • INSTALLATION OF A PV SYSTEM MOUNTED ON INSTRUCTIONS" RESIDENTIAL BUILDING. • A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS • 2017 NEW, 2020 IRC 0 ALL WORK SHALL COMPLY WITH 2017 NEC,2020 IRC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTION. • MAIN BREAKER DERATE:.REPLACE EXISTING MAIN PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2017 NEC. r BREAKER WITH NEW 80 AMP MAIN BREAKER. • PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. 0 • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF 09/06/2022 REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. • CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8"ABOVE Firm License Number:COA0012807 ROOF SURFACE. VSE Project Number:02557.0813.221 UNAUTHORIZED ALTERATIONS OR ADDITIONS TO A DOCUMENT BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF SECTION 7209(2)OF THE N.Y. STATE EDUCATION LAW Vector Structural Engineering has reviewed the existing structure with loading from the solar array and screw connections to the existing framing. VICINITY MAP The design of the racking system,racking connections,and all other structural is by others. Mechanical,architectural,and all other nonstructural aspects of the design are by others. - Electrical is by others,unless stamped by Dean Levorsen. OWNER INSTALLED NIP 3 2.s mer 11 71 S Pc ChuJI-t_P1 JOSE UMANA 51750 MAIN RD SOUTHOLD NY 11971 Email:Joseumana06@gmail.com .01750 main Rd, Phone:6.31-830-1484 Southold, NY 1-1971 ... ���,� �� � �, REV I ! DATE:1 July 2022 COVER SHEET _ u�rl � PV 1 .0 mc r' -`.- .� SchoolJ =3 C t.L•- � `�F'l 1 L 11 t�.+F� t� SITE PLAN: 1/32" = V-0" SOLAR ROOF ROOF ROOF ARRAY ROOF AREA AREA COVERAGE SOLAR AREA # MOD SLOPE TILT AZIMUTH (SQFT) (SQFT) M (LBS) N AR-01 180 180 1820 518.78 1280 40.53 1182.62 29 (E)RESIDENCE - (E)STRUCTURE(TYP.) LEGEND �M METER MP MAIN SERVICE PANEL © AC DISCONNECT I I F1Q1 IQ COMBINER DD 0 a JB JUNCTION BOX I SP SUB PANEL Z I (E)SUB PANEL(INDOOR) 0 (E) DRIVEWAY ' I (E)FENCE ROOF ACCESS POINT (N)ARRAY AR-01 ROOF MODULE LAYOUT + EQUIPMENT LOCATIONS:1/16" = 1'-0" Vector Structural Engineering has reviewed the existing structure with loading from the solar array and screw connections to the existing framing.The design of the racking system,racking connections,and all other structural is by others.Mechanical,architectural,and all other nonstructural aspects of the design are by others. N Electrical is by others,unless stamped by Dean Levorsen. (E)UTILITY METER (E)CHIMNEY (N)AC DISCONNECT (TYP) _ VECTOR OWNER INSTALLED (N)IQ COMBINER E n O I n E E R 9 ' 651 W.GALENA PARK BLVD.ETE. 101 PHONE(8011 990-1775 DRAPER,UTAH H4020 WWW.VECTOR5E.COM OF EJp (E)MAIN SERVICE PANEL, 100A RATED,240V CONDUIT RUN JOSE UMANA (IN THE ATTIC) 51750 MAIN RD ❑ ~ ° ❑ ❑ ❑ SOUTHOLD NY 11971 O (N)JUNCTION BOX Email:Joseumana06@gmail.com Icy - AAAAAAAAAAA Phone:631-830-1484 09/06/2022 B B B B B B B A A A A REV A B B B DArE:1 July 2022 B Firm License Number:COA0012807 B B p VSE Project Number:02557.0813.221 SITE PLAN UNAUTHORIZED ALTERATIONS OR ADDITIONS TO A DOCUMENT BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF SECTION 7209(2)OF THE N.Y. p� / .O STATE EDUCATION LAW r V # MODULES PER ARRAY ROOF TYPE ATTACHMENT ROOF HEIGHT FRAME MATERIAL FRAME TYPE FRAME SIZE OC SPACING ` AR-01 29 COMP SHINGLE IRONRIDGE FLASHVUE ONE STORY WOOD TRUSS 2"X4" 24"O.C. AR-01 SCALE: 3/16"= 1'-0" PITCH: 18° 0'-6" 2'-1014 AZIMUTH: 182° 10, 36'-734' ?POINT LOAD CALCULATION_ 4'-0" ITEM #OR WEIGHT LIN FT ER(lbs) TO(IbsAL WEIGHT N MODULES 29 40.78 1182.62 { I I ' 10'-6" RAILS 159.54 0.4 69.6 i i I i i i i I i I i I I ATTACHMENTS 61 0.65 39.65 ARRAY AR-01 I I I i ! ` I I i TILT LEGS 0 3.5 0 ENPHASE ? I I I I I I 1 I INVERTER 29 1.4 40.6 ! I ! I I 1 TOTAL WEIGHT 1332.4 lbs l I I I I I I I ( I I I I I MODULE DIMENSION (LxW) 65.95 x 39.06= 17.88 sq.ft I i i I 14'-5" WEIGHT PER MOUNT 1332.4/ 61 = 21.8 Ibs/Mount 2"X4" TRUSS @ 24" I , I I I i WEIGHT PER SQ FT 1332.4/ 518.52 sq.ft.=2.6 Ibs/sq.ft. IRONRIDGE FLASHVUE -(29) ENPHASE IQ8-60-2-US ATTACHMENTS MICROINVERTERS IRONRIDGE XR100 RAIL SYSTEM 6'-7" OWNER INSTALLED �/ Vector Structural Engineering has reviewed the existing E C T O R structure with loading from the solar array and screw E n O I n E E R 8 connections to the existing framing.The design of the 3'-3 See structural letter for racking system,racking connections,and all other u i re 651 W.GALENA PARK BLVD.ST£. 107 PHONE(8O 11 990-7775 structural is by others.Mechanical,architectural,and all roof areas that re DRAPER,UTAH B4020 WWW.VECTORSE.DON other nonstructural aspects of the design are by others. tighter Lighter connection Electrical is by others,unless stamped by Dean Levorsen. 1-o spacing than listed. * * DESIGN CRITERIA JOSE UMANA 51750 MAIN RD MODULES: SOUTHOLD NY 11971 5'-6" 3'-6" 29 Email:Joseumana06@gmaii.com MAX DISTRIBUTED LOAD: 3 PSF Iib SNOW LOAD: 25 PSF Phone:631-830-1484 WIND SPEED: 136 MPH 3-SEC GUST. REVA 09/06/2022 LAG SCREWS: DATE:1 July 2022 Firm License Number:COA0012807 5/16"x 2.5"MIN EMBEDMENT VSE Project Number: U2557.0813.221 NOTE: LAYOUT DETAIL UNAUTHORIZED ALTERATIONS OR ADDITIONS INSTALLERS TO VERIFY RAFTER TO-A DOCUMENT BEARING A LICENSED SIZE, SPACING AND SLOPED PROFESSIONAL ENGINEER'S SEAL IS A SPANS,AND NOTIFY E.O.R. OF NOTE:-MAX.ATTACHMENT SPACING IS 4'-0" VIOLATION OF SECTION 7209(2)OF THE N.Y. ANY DISCREPANCIES BEFORE PV' 3.0 (STAGGERED) STATE EDUCATION LAW PROCEEDING. VECTOR E ri' O i n E E R S 651 W.GALENA PARK BLVD.STE. 101 PHONE(80 71 990-7 775 DRAPER, UTAH 84020 WWW.VECTORSE.COM PV MODULE 'k 0 OG 09/06/2022 (E) SINGLE-LAYER OF Firm License Number: 0 AOO 07 COMPOSITE SHINGLE VSE Project Number:U2557.0813.221 UNAUTHORIZED ALTERATIONS OR ADDITIONS TO A DOCUMENT BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF SECTION 7209(2)OF THE N.Y. STATE EDUCATION LAW SEE (2/PV-4.0) FOR Vector Structural Engineering has reviewed the existing structure with loading from the solar array and screw ENLARGED VIEW connections to the existing framing.The design of the racking system,racking connections,and all other structural is by others.Mechanical,architectural,and all other nonstructural aspects of the design are by others. Electrical is by others,unless stamped by Dean Levorsen. 1 ATTACHMENT DETAIL } PV-4.0 SCALE: 1"=1' PV MODULES IRONRIDGE INTEGRATED GROUNDING & END/MID ; CLAMP `ti� IRONRIDGE FLASHVUE ATTACHMENTS t ` OWNER INSTALLED IRONRIDGE XR100 RAIL ALUMN. "L" BRACKET W/3/8" SS BOLT& NUT (E) SINGLE LAYER OF COMPOSITE SHINGLE JOSE UMANA IRONRIDGE FLASHVUE 51750 MAIN RD .FLASHING 5/16"X4.25" SS LAG SCREW SOUTHOLD NY 11971 WITH MIN 2%2'THREAD . Email:Joseumana06@gmail.com EMBEDMENT, SEALED Phone:631-830-1484 2"X4" TRUSS @ 24" O.C. PENETRATION REV A DATE:1 July 2022 MOUNTING DETAIL 2 ATTACHMENT DETAIL ( section view) PV-4.0 SCALE: NTS PV 4.0 CONDUIT SCHEDULE GROUND SYSTEM SIZE:9280W DC,696OW AC NOTE: CONDUCTOR ENPHASE MICRO INVERTERS ARE EQUIPPED WITH RAPID **ENVOY BREAKER CAN BE 10A OR 15A IN IQ COMBINER BOX, # CONDUIT (RED/BLACK) NEUTRAL(WHITE) (GREEN) (BARE COPPER) SHUTDOWN FUNCTION PER NEC 690.12. REFER TO TECHNICAL BRIEF IN ATTACHED SPEC SHEETS. 1 NONE ENPHASE Q-CABLE NONE NONE (1)#6 • 2 3/4"EMT (4)10 AWG NONE (1)6 AWG NONE MAIN BREAKER DERATE: REPLACE EXISTING MAIN THHN/THWN-2 THHN/THWN-2 BREAKER WITH NEW,80 AMP MAIN BREAKER. 3 3/4"EMT (2)8 AWG (1)8 AWG (1)6 AWG NONE THHNfrHWN-2 THHNfTHWN-2 THHN/THWN-2 3 (N)LOCKABLE EXISTING WIRING BLADE TYPE 3 IQ COMBINER AC DISCONNECT BOX 2 1 2P 2P 15A** 80A PHONO SOLAR PS320MH-20/UH (MONITORING) NEW 15 ENPHASE IQ8-60-2-US � � M M M (1)CIRCUIT OF(15)MODULES °tl"Q iti 2P STRING A,ARRAY 1 1 20A-2P 40A SOLAR BREAKER n PHONO SOLAR AT OPPOSITE 1A 2/`1 3A PS320MH-20/UH :: 20A-2P END OF •:::: INN;14 ENPHASE IQ8-60-2-US • � BUSBAR (1)CIRCUIT OF(14)MODULES NEW 60A Ac I STRING B,ARRAY 1 JUNCTION BOX DISCONNECT EXISTING i EXISTING METER ENPHASE IQ MAIN PANEL AL OVERHEAD UTILITY SERVICE MIN RATED (2-POLE - NEMA3R COMBINER BOX, UNFUSED) 100A BUSBAR 125A RATED END FED (X-I Q-AM 1-240-4C) INVERTERS RATING MAKE ENPHASE MODEL IQ8-60-2-US MAX INPUT CONDUCTOR SIZING CALCULATIONS CURRENT 15A CURRENT CIRCUIT CURRENT Imax(690.8(A)) Icont(690.8(6)(1)) SPECIFIED AMPACITY @ AMBIENT CARRYING COND. OF USE APPLIED MAX POWER 240W DESCRIPTION calc CONDUCTOR 90C TEMP c COND. (690.8(B)(2))calc (AC) PV SOURCE. 15.00A x 1.25= 40A x 0.96(am b.temp.)x0.80 NOM.AC 240V CIRCUIT A 15.00A 15.00A 18.75A #10 THWN-2 40A 31-35 4-6 (raceway fill)=30.72A OWNER INSTALLED VOLTAGE PV SOURCE 40A x 0.96(am b.temp.)x0.80 MAX AC 1A CIRCUIT B 14.00A. 14.00A 14.00A x 1.25= 17.5A #10 THWN-2 40A 31-35 4-6 (raceway fill)=30.72A CURRENT CEC COMBINER BOX 2929.00A x 1.25= 55A x 0.96(am b.temp.)x1 EFFICIENCY 97% OUTPUT .00A 29.00A 36.25A #8 THWN-2 55A 31-35 1-3 (raceway fill)=52.8A MODULE AND ARRAY RATINGS: (29)MODULES) TERMINAL TEMPERATURE RATING CONSIDERATIONS JOSE UMANA SOLAR MODULE RATINGS (STC) CIRCUIT A CIRCUIT B TERMINAL TEMP SPECIFIED AMPACITY @ 51750 MAIN RD CIRCUIT DESCRIPTION CURRENT (cont TERMNAL TEMP. MAKE PHONO SOLAR SERIES 1 1 RATING CONDUCTOR RATING SOUTHOLD NY 11971 PV SOURCE CIRCUIT A 15.00A 15.00A x 1.25= 18.75A 75C #10 35A Email:Joseumana06@gmaii.com MODEL PS320MH-20/UH PARALLEL 15 14 PV SOURCE CIRCUIT B 14.00A 14.00A x 1.25= 17.5A 75C #10 35A Phone:631-830-1484 COMBINER BOX OUTPUT 29.00A 29.00A x 1.25=36.25A 75C #8 50A ' REV A Imp 9.69A Imp 15.OA 14.OA VOLTAGE DROP CALCULATIONS DATE:1 July 2022 Vmp 33.01V Vmp 240V 240V CIRCUIT DESCRIPTION LENGTH I Ohms/kFt V CALC Vdrop Ise 10.13A Ise 15.OA 14.OA PV SOURCE CIRCUIT A 50Ft 15.00A 0.9989 240V 50'x 15.00A x-2 x 0.9989/1000'/240V= 0.62% ELECTRICAL Voc 39.92V Voc 240V 240V PV SOURCE CIRCUIT B 50Ft 14.00A 0.9989 240V 50'x 14.00A x 2 x 0.9989/1000'/240V= 0.58% Pmax 320W Pmax 3600W 3360W COMBINER BOX OUTPUT 30Ft 29.00A 0.6282 240V 30'x 29.00A x 2 x 0.6282/1000'/240V= 0.46% %Voc/C -0.306% PV 5.0 INSTALL ON THE UTILITY METER INSTALL ON THE AC DISCONNECT NZ III PHOTOVOLTAIC THIS SERVICE METER AAC DISCONNECT I CAUTION : IS ALSO SERVED BY A POWER TO THIS BUILDING IS ALSO SUPPLIED PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: 29.00A FD SCONNECOTSTHE OLOCATED AS SHOWN H WING SOURCES NOMINAL OPERATING AC VOLTAGE: 240V INSTALL ON THE MAIN BREAKER PANEL PHOTOVOLTAIC SOLAR SUB PANEL PV ARRAY PHOTOVOLTAIC SYSTEM AC DISCONNECT (INDOOR) .EQUIPPED RAPID SHUTDOWNWARNING ELECTRIC SHOCK HAZARD MAIN SERVICE RAPID SHUTDOWN PANEL ARRAY � - � TERMINALS ON THE LINE AND ' IQ COMBINER UTILITY METER LOAD SIDES MAY BE ENERGIZED (NP.) TO BE INSTALLED IN ACCORDANCE IN THE OPEN POSITION Ac DISCONNECT WITH SECTION 690.56(C): 51750 Main Rd,Southold,NY 11971 ACAUTION SOLAR PV SYSTEM SOLAR ELECTRIC SYSTEM CONNECTED EQUIPPED WITH INSTALL-INSIDE THE MAIN BREAKER RAPID SHUTDOWN PANEL, NEXT TO THE SOLAR BREAKER R ELECTRIC SOPVPANELS - OWNER INSTALLED OWARNING - POWER SOURCE INSTALL ON THE PV OUTPUT CONNECTION. AC COMBINER BOX DO NOT RELOCATE THIS TURN RAPID SHUTDOWN SWITCH TO (IF APPLICABLE) OVERCURRENT DEVICE THE"OFF"POSITION TO SHUT DOWN PV SYSTEM AND REDUCE JOSE UMANA SHOCK HAZARD IN THE ARRAY WARNING 51750 MAIN RD PHOTOVOLTAIC SOUTHOLD NY 11971 Email:Joseumana06@gmail.com INSTALL EVERY 10 FEET ON EXTERIOR CONDUIT. PHOTOVOLTAIC SYSTEM SOLAR BREAKER Phone:631-830-1484 COMBINER PANEL WARNING: PHOTOVOLTAIC REV A DO NOT ADD LOADS DATE: July 2022 DO NOT RELOCATE THIS POWER • OVERCURRENT DEVICE WARNING LABELS PV 6.0