Loading...
HomeMy WebLinkAbout49380-Z Town of Southold 7/6/2023 P.O.Box 1179 o _ 53095 Main Rd y �ao�rfiSouthold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44255 Date: 7/6/2023 THIS CERTIFIES that the building AS BUILT ADDITION Location of Property: 11219 Sound Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 141.-3-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/12/2023 pursuant to which Building Permit No. 49380 dated 6/14/2023 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built"additions and alterations including wood landing decks to an existing one family dwelling as 4pplied for The certificate is issued to Paladino,Robert&Tammy of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49380 06/23/2023 PLUMBERS CERTIFICATION DATED Author z d Signatu % suFFoi TOWN OF SOUTHOLD BUILDING,DEPARTMENT H x TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49380 Date: 6/14/2023 Permission is hereby granted to: Paladino, Robert PO BOX 635 Mattituck, NY 11952 To: legalize "as built" additions and alterations to existing single-family dwelling as applied for. Additional certification may be required. At premises located at: 11219 Sound Ave, Mattituck SCTM # 473889 Sec/Block/Lot# 141.-3-2 Pursuant to application dated 5/12/2023 and approved by the Building Inspector. To expire on 12/13/2024. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $441.60 CO-ADDITION TO DWELLING $50.00 Total: $491.60 Bui ding Inspector pf SO!/T�,ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlina-town.southold.ny.us Southold,NY 11971-0959 Q�yOUN'i`1,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Robert Paladino Address: 11219 Sound Ave city:Mattituck st: NY zip: 11952 Building Permit#: 49380 Section: 141 Block: 3 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: REP Electric License No: 46288ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor X Pool New Renovation X 2nd Floor X Hot Tub Addition Survey X Attic X Garage INVENTORY Service 1 ph Heat Duplec Recpt 23 Ceiling Fixtures 6 Bath Exhaust Fan 2 Service 3 ph Hot Water GFCI Recpt 8 Wall Fixtures 2 Smoke Detectors 4 Main Panel A/C Condenser Single Recpt Recessed Fixtures 44 CO2 Detectors Sub Panel A/C Blower Range Recpt Elec Ceiling Fan Combo Smoke/CO 3 Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 5 4'LED Exit Fixtures Sump Pump Other Equipment: Fridge, Oven, DW, Micro/ Hood, Floor Heat, 4- Combo ARC/ GFI Braekers Notes: " AS BUILT NO VISUAL DEFECTS " New Kitchen & HH's Everywhere Inspector Signature: ate: June 23, 2023 S.Devlin-Cert Electrical Compliance Form E51 G N 5 M �� ATJD ARCHITECTURE&PLANNING,PC DI ) July 6",2023 Jill - 6 2023 Nancy Meyer BUH DING DIED r. Town Hall Annex Building TOY'` 54375 Route 25 P.O.Box 1179 Southold,NY 11971 nancy.meyer@town.southold.ny.us Re: Paladino Residence Certification Letter 11219 Old Sound Avenue,Mattituck,NY 11952 ATJD#2304-02 Dear Ms.Meyer, This is to certify that to the best of my knowledge, based on my analysis of owner-provided photos during construction,visual reviews and conversations with the owner and the contractor that the following newly constructed elements meet the requirements of the current building code and are reflected in the drawings created by this office dated 5/11/2023: • Exterior entrance stair concrete footings • Entrance stair ledger board secured to existing foundation framing • Framing of new 2-2x 12 laminated veneer lumber beams • Wall and rafter insulation at exposed walls only Sincerely, ���ED A Roti ATJD Architecture&Planning,P.C. \� P I d E'q o n s No. 0205° Q� Mia Jealous-Dank,RA,MPA �TFOF NE`Ny� MJD/md P.O.BOX 944 NYS CERTIFIED WBC CUTCHOGUE,NY 11935 NYC SBS CERTIFIFD WBF PANYNJ CERTIFIED DBE&WBC C•631943 6501 PAGE 1 OF 1 mia@atjdarchitecture.com C:1Usem\Wa\Dropbo)M2_4TJD Ardtedm\ATJD DesignMUD Projects 202312304-02-ATJ0Pab(Enc 11219 Old Sowd Ave\Cert LeteA2304-02_Pa1a&ia CeA Ur doc OF SOUIyo # # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: U DATE 12,* INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS FOUNDATION (1ST) � y ------------------------------------ — C ' FOUNDATION (2ND) z �O vn H ROUGH FRAMING& a PLUMBING � 1 1 Q r INSULATION PER N. Y. ��-- STATE ENERGY CODE FINAL ADDITIONAL COMMENTS 2l 23 QA-,Qt P-f—CO 04 :7W77l04.Ofi/Z .G a 4 u 2 Wee, rc c cxFTV9 /2.5-.vp W* o � z m o -- H x r� b H d'gUFFOLKC^.t., TOWN OF SOUTHOLD—BUILDING DEPARTMENT y =` Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 y o Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny,Rov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only q PERMIT NO. Building Inspector: Nlh Applications and forms must be filled out in their entirety. Incomplete IiUIWINVUtPI. applications will not be accepted. Where the Applicant is not the owner,an -row�+oFsrn►�nl r Owner's Authorization form,(Page 2)shall be completed. „ Date:4/21/23 OWNERS)OF PROPERTY:" Name:Robert & TammY,Paladino SCTM# 1000-141-3-2 Project Address:11219 Old Sound Ave Mattituek, NY 11952 Phone#:631-767-4338 Email:REPelectric1 MailingAddress:PO Box 635 Mattituck, NY 11952 CONTACT PERSON: Name:Tammy Palladino Mailing Address:PO Box.635 Mattituck, NY 11952 Phone# 631_-767-4338, E1ma�I:tpaladino4.16,0@gmail.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: A Plo 'e° l`i .j9.3� ;llf Email: y �71 • 1,r. .n• �r 3 J0 56. CCifVTRACiQFt:If�F _CasJ-94 ,OR, ATION: Mailing Address: Phone#: Email: DESCRIPTION,OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: lil Other Existing structure j\ �( $N/A Will the lot be re-graded? ❑Yes ONo Will excess fill be removed from premises? ❑Yes ®No 1 t PROPERTY,INFORMATION _ }:•�`: ` , Existing use of property:Re$Ide_Cht.la�, Intended use of property:ReSI,deCltla�,- „_ Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R4O reSldentlaj this property? ❑Yes 8No IF YES, PROVIDE A COPY. ❑'Check Box After Reading:.'The owner/contractor/design professional is responsible"for.all drainage and storm water issues as'provided Mby- chapter 23q of,the-Town Code:'--APPLICATION IS HEREBY.MADE to the,Building.Departinent for the issuance-of a Building Per•mit,pursuant to the Building Zone' Ordinance df the;To"of Southold;Suffolk,County,New York and.other applicable Laws,Ordinances or Regulations,foi the,construction of'buildings, addit ons alterations or for removal or demolitionas;herein de'sdibed.:The-applicant agrees to•comply_wiih,all applicable laws',ordinances,building code,:. housing code and regulations and to admit authorized-inspectors on.premises and in buildirigis)'for necessary,inspections.False.statements made herein are punishable as a ClassiA'misdemeanor pursuant'to'section 210.45 of the New York'State Penal Law. I.: ' e ` Tamm Paladino Application Submitted B (print name): y ❑Authorized Agent ®Owner Signature of Applica i Date: 4/21/2023 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Tammy Paladino being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the owner (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of "17IL— 20-:1,7 14zid/ry Public STEVEN L HARNED PROPERTY OWNER AUTHORIZATION Notary Public State of New Yod (Where the applicant is not the owner) No.OltlA6071848 Qualified inSuffolk County Commission Expires March 3; �Ie I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 c��` I•t�. , BUILDING DEPARTMENT- Electrical Inspector ©ti C��� TOWN OF SOUTHOLD 9 Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(aD-southoldtownny.gov - seand(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company,Name: R � +Lc Electrician's Name: yon License No.: Elec. email: Elec. Phone No: request an email copy of Certificate of Compliance Elec. Address.: p p k, _ JOB SITE INFORMATION (All Information Required) Name: Rcup - - o\j Address: ( 1 2d ( ice 5 ©u. �7 �( Y Cross Street: FAc4oew A L LF. Phone No.: e3 Bldg.Permit#: ( � email: 2_ / -9 ' Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): o � 2_ ,-�45 -fe5 — Square Footage: Circle All That Apply: Is job ready for inspection?: WYES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect E]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y RN Additional Information: PAYMENT DUE WITH APPLICATION rQ c Z#_9f 9 I6PA, c_9 3ea S�ffO(KC BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 v' Southold, New York 1197170959 ©9,► p�� Telephone (631) 76521802 - FAX (631) 765-9502 rogerr D-southoldtownny.gov — seand(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: Company Name: Electrician's Name: License No.: c Elec. email: Elec. Phone No: (o �0= 1 request an email copy of Certificate of Compliance Elec. Address.: PC o > JOB SITE INFORMATION (All Information Required) Name: OSP Y '}- a� nn. Address: ( � .Z 1 h � � S ©v� v i �• L �( >/ 2n (41 1 �\J L Cross Street: FAc4c--),.�v A u Phone No.: Bldg.Permit#: email: ? ( - 1 n, ,&A Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): L �,,<45 L,,o 31 Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑ Rough In ❑ Final Do you need a Temp Certificate?: YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# El New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION 4� /2 A, PERMIT 9 C Address: Switches Outlets r? f 2?i G F I's y II t7 Surface Sconces H H's � W Ill UCLts Fans Fridge/ HW ExhaustOven / W/D Smokes �� DW Mini Carbon Cood icro/ Generator Combo I I ooktop Transfer n1C AH / Service Amps Have Usec special: -omments Generated by REScheck-Web Software Compliance Certificate Project 11219 Old Sound Ave, Mattituck 0 Location: Mattituck, New York Construction Type: Single-family Project Type: Alteration Climate Zone: 4 (5331 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 11219 Old Sound Avenue Robert Paladino Mia jealous-Dank Mattituck, NY 11952 PO Box 635 ATJD Architecture&Planning, PC Mattituck, NY 11952 800 Cox Lane 6317676034 PO Box 944 Cutchogue, NY 11935 6319436501 mia@atjdarchitecture.com Corn,pilance- Passes us ing prescriptive requirements for alteration projects Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Prop.Gross Area Cavity Cont. Perimeter Window:Vinyl Frame 27 0.300 0.300 8 8 SHGC: 0.31 Window:Vinyl Frame 19 0.280 0.300 5 6 SHGC: 0.31 Door: Glass Door(over 50%glazing) 20 0.290 0.300 6 6 SHGC:0.25 Additional Efficiency Package(s) 41 Not applicable f Project Title: 11219 Old Sound Ave, Mattituck Report date: 05/12/23 Data filename: Page 1 of10 Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2021 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory renquirements listed in the REScheck Inspection Checklist. Mia Jealous-Dank,RA,MPA-Architect 5/12/2023 Name-Title Signamure Date Project Title: 11219 Old Sound Ave, Mattituck Report date: 05/12/23 Data filename: Page 2 of 10 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2021 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section - ' , Plans Verified F�eltl,Nerifietl # Pre Inspection/Plan Revieuv,: 'r,s Comphes� Comments/Assumptions.: _Value Value, 103.1, ;Construction drawings and E ;. = '_ ❑Complies" 103.2 documentation demonstrate ( =` ❑Does Not [PRI]1 :energy code compliance for the (= !building envelope.Thermal (" []Not Observable envelope and energy compliance LL__❑Not Applicable path represented on construction documents. 103.1, Construction drawings and ❑Complies 103.2, :documentation demonstrate r 311Does Not 403.8 ;energy code compliance for ° J [PR3]1 ;lighting and mechanical systems. .` "- 1❑Not Observable :Systems serving multiple f ❑Not Applicable ; dwelling units must demonstrate ;compliance with the IECC :Commercial Provisions. : 3Heating and cooling equipment is; Heating: ; Heating: v ,❑Complies 02;1; 403:7' :"sized per ACCA Manual S based : Btu/hr : Btu/hr :❑Does Not [PR2p on loads calculated per ACCA I Coolin Manual J or other methods g: ; Boling: t❑Not Observable B approved by the code official. ; tu/hr ;❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) -F,—[—Impact(Tier 2) •3_: Low Impact(Tier 3) Project Title: 11219 Old Sound Ave, Mattituck Report date: 05/12/23 Data filename: Page 3 of 10 Section Foundation Inspection Complies?° Comments/Assumptions &'Req:ID k 303._2A :,"A protective covering is installed to ;❑Complies [FO11]2 .::::protect exposed exterior insulation ;❑Does Not and extends a minimum of 6 in. below ;❑Not Observable , ❑Not Applicable 403.9;:;:`:::,;Snow and ice-melting system controls ;❑Complies [F012j3';;-installed to shut off system when :❑Does Not ,pavement temperature> 50F and no precipitation. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) -2; Medium Impact(Tier 2) :3.,. Low Impact(Tier 3) Project Title: 11219 Old Sound Ave, Mattituck Report date: 05/12/23 Data filename: Page 4 of 10 Section Plans Verified F®Id Verified "-A V " # Framing/Rough In Inspection Complies Comments/Assumptions Value !.'"Value 402.1, ;Glazing U-factor(area-weighted U- , U- ;❑Complies ;See the Envelope Assemblies 402.3.1, :average). ;❑Does Not table for values. 402.3.3, ;❑Not Observable 402.5 ;❑ [FR2]1 ; Not Applicable I I I I 303.1.3 ;U-factors of fenestration products r'= ',, „; ;-.-;a; .;" :,'-- r :,:, ❑Com lies P [FR4]1 :are determined in accordance []Does Not ;with the NFRC test procedure or ;taken from the default table. ❑Not Observable ; 1 []Not Applicable ; 402.4.1.1 :Air barrier and thermal barrier [ 3❑Complies [FR23]1 installed per manufacturer's ❑Does Not j J instructions. :+- _ "i❑Not Observable ❑Not Applicable 402.4.3 ;Fenestration that is not site built .. ,:;. " >- _ w :a. =i)❑Complies [FR20]1 :is listed and labeled as meeting =❑Does Not j AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC []Not Observable tt 1400 that do not exceed code ❑Not Applicable t: limits. l-_ - 402.4.2 IC-rated recessed lighting fixtures y :-❑Complies 1 [FI216]° !sealed at housing/interior finish ❑Does Not land labeled to indicate:52.0 cfm jleakage at 75 Pa. „ T j❑Not Observable , r NotApplicable 403.3.1 ;Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is i ❑Does Not ; >=3 inches in diameter and >_ :11-6 where< 3 inches. []Not Observable I ...' '.� ❑Not Applicable I F. 403.3.4 ;Ducts, air handlers and filter `• ❑Complies [FR13]1 :boxes are sealed with 1[]Does Not joints/seams compliant with { International Mechanical Code or "=❑Not Observable ; ,.'❑Not Applicable International Residential Code,as I.:.;. 'applicable. I 3 403.3:7 Building cavities are not used as ❑Complies [FR15]3:. educts or plenums. . ❑Does Not ❑Not Observable ❑Not Applicable 403,4- HVAC piping conveying fluids R- 1 R- :❑Complies [FR17]2 labove 105°F or chilled fluids : : ❑Does Not . j below 55°F are insulated to >_R- 3 ; ❑Not Observable t Not Applicable ; 403.4.1 ;Protection of insulation on HVAC :R= gigi❑Complies [FR24]1 (piping. _a❑Does Not tJ }11'❑Not Observable ❑Not Applicable 402:4.6 - ;Electrical and communication ,`;: ;`',_;,` ;_°, ❑Complies [FR29]3 -::boxes installed in the thermal _j❑Does Not boundary of the envelope sealed . ❑Not Observable ; to limit air leakage between EE conditioned and unconditioned t. " = ❑Not Applicable (spaces. s 403.5.2: 'I'Hot water pipes are insulated to I R- R- . illcomplies ;❑Does Not '❑Not Observable ;❑Not Applicable 1 High Impact(Tier 1) l2:' Medium Impact(Tier 2) +3,.I Low Impact(Tier 3) Project Title: 11219 Old Sound Ave, Mattituck Report date: 05/12/23 Data filename: Page 5 of 10 Section`. -- Plans Verified Feld Verified - Framing L Rough In Inspection ;, : Comploes� Comments/assumptions &'Req:ID' = _ Value- Value 403;6 °;Automatic or gravity dampers are • :: =`i❑Complies ; I [FR19lz ' ;installed on all outdoor air ❑Does Not l intakes and exhausts for " f mechanical ventilation system's. ❑Not Observable ❑Not Applicable 403:6:1 ':''i Ventilation systems in climate ❑Complies 0301. ;:J zones 7&8 shall utilize heat or _:f;;`.,,,; __-, ❑Does Not i energy recovery ❑Not Observable Eti ]❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) ;2_, Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 11219 Old Sound Ave, Mattituck Report date: 05/12/23 Data filename: Page 6 of 10 ts/AssuMptions Inspection e�r! Insulation!on 303.1 . All installed insulation is labeled or the;E]Cornplies [IN13]2'-,. installed R-values provided. :E]Does Not bNot Observable; [INot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 1",2-,,J Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 11219 Old Sound Ave, Mattituck Report date: 05112/23 Data filename: Page 7 of 10 _Section. a Plans Verified .;Field,Verified:-, #.., Final.Inspec#ion Provisions .;VaComploes� Comments/Assumptions, &.Req.ID lue Value 402.2.4 ;Attic access hatch and door ; R- ; /R- ❑Complies [FI311 insulation zR-value of the I :,[--]Does Not !adjacent assembly. ;❑Not Observable ❑Not Applicable 402.4.1.3 ;Blower door test @ 50 Pa. <=5.0 j ACH 50= ; ACH 50 = ;❑Complies ; [F117]1 ;ach in Climate Zones 1-2,and ❑Does Not <=3.0 ach in Climate Zones 3-8. '❑Not Observable {❑Not Applicable 403.3.5 ;Ducts are pressure tested in cfm/100 ; cfm/100 ;❑Complies ; [FI27]1 accordance with ft2 ft2 !❑Does Not ;ANEI/RESNET/ICC 380 or ❑Not Observable ' ASTME1554 to determine air ; leakage with either: Rough-in I ;❑Not Applicable ; ;test:Total leakage measured ;with a pressure differential of 0.1 I inch w.g,across the system ! I 1 including the manufacturer's air I handler enclosure if installed at ,time of test. Postconstruction I ! ;test:Total leakage measured ;with a pressure differential of 0.1 {inch w.g.across the entire system including the manufacturer's air handler I enclosure. 403.3.6 Duct tightness test result of<=4 ; cfm/100 cfm/100 ;❑Complies [FI411 I cfm/100 ft2 across the system or I ftz ft2 ;❑Does Not <=3 cfm/100 ft2 without air ; handler @ 25 Pa.Duct tightness ; ! :❑Not Observable I <= 8 cfm/100 ft2 for ducts within! ; ;❑Not Applicable ; ;thermal envelope. For rough-in I tests,verification may need to ; !occur during Framing Inspection. 403.3.4.1 ;Air handler leakage designated ❑Complies ; [FI24]1 !by manufacturer at<=2%of j.�❑Does Not design air flow. E Not Observable ❑Not Applicable 403:1:1 :';Programmable thermostats ❑Complies [Fl9]2:: ' !installed for control of primary : - *Ay'' ❑ heating and cooling systems and Does Not initial! set b manufacturer to ; c❑Not Observable y y " " ]❑Not Applicable code specifications. r b PP 403.5:1 ;Circulating service hot water _ }❑Complies ; [Fl ll]z asystems have automatic or I ❑Does Not !accessible manual controls. j ❑Not Observable J❑Not Applicable 403.2 ' i Hot water boilers supplying heat +4-'; ❑Complies [FI26]2through one-or two-pipe heating 4 ❑Does Not ,,systems have automatic outdoor setback control to lower boiler ❑Not Observable water temperature based on ❑Not Applicable outdoor temperature, indoor (temperature or water .temperature sensing. 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 11219 Old Sound Ave, Mattituck Report date: 05/12/23 Data filename: Page 3 of 10 ` OMP.ii 403;5.Ll- Heated water circulation systems []Complies E]Does Not [F12 J have a circulation pump.The ;.IJsystem return pipe is a dedicated []Not Observable return pipe or a cold water supply []Not Applicable pipe. Gravity and thermos- 'Isyphon circulation systems are ating hot water system Jcircul s t rt the pump with signal for hot water demand within the _4 occupancy.Controls automatically turn off the pum when water is in circulation loop is at set-point temperature and no demand for hot water exists. DComplies 403.5.1'.Z.:J Electric heat trace systems comply with IEEE 515.1 or UL v.- []Does Not 1515 Controls automatically []Not Observable adjust the energy input to the heat tracing to maintain the E]Not Applicable desired water temperature in the DComplies !Drain water heat recovery units F131-]2,'- - �testecl in accordance with CSA L E]Does Not Potable water-side ble pressure loss of drain water heat able d* 'd I units connected to one or w �side pressure loss of drain water I heat recovery units <2 psi for d' 'd I units connected to `three or more showers. -3.0.'2 All mechanical ventilation system _g, 'M 5]2 fans not part of tested and listed HVAC equipment meet efficacy []Not Observable and air flow limits per Table ,,..�L]Not Applicable 403.6.'j-',-1,Mechanical ventilation systems []Complies [F133 12', and verified to meet the es Not minimum flow rates required by E]Not Observable "Section R403.6. []Not Applicable 403,5 11-, Demand recirculation water Complies I systems have automatic con ro s E]Does Not [F132 to start pump when hot water is '[]Not Observable 0Not Applicable 404.1 100%of permanent fixtures have []Complies [F1611 high efficacy lamps. . . .... E]Does Not Observable []Not Applicable 404J--.2,,`L.:Fuel gas lighting systems have [F123]3 �Ino continuous pilot light. Does Not Not Applicable 404.1.1- Exterior lighting for multifamily [171j5]3,"'r_'�-i buildings shall comply with E]Does Not tion C405.4. iSeL []Not Observable I High Impact(Tier 1) Medium Impact(Tier 2) 13 Low impact(Tier 3) Project Title: 1121gOld Sound Ave, Mnttituck Report date: 05/12/23 Qatefi|ename: Page goflO Seict!46W t Runs Verified- - d Veirfibd".' a FinaUllifspec ns--- Complies' Up F-F I M E- &'Req Value-.. . , AWI, 404.2:',-,1 Permanent interior lighting shall OComplies F113613 Li be controlled with either a E]Does Not dimmer,occupancy sensor or ;other control built into the 0Not Observable 'fixture. EINot Applicable � 3.,, Exterior 4P4. lighting >= 30 watts 7- ElComplies [F137]3 ,shall have the following controls: -- DDoes;Not manual on/off switch with automatic shut-off, automatic and EINot Observable shut-off in daylight hours, 'EINot Applicable % Icontrols that override automatic shutoff that returns to automatic !control within 24 hours. 401.3 J Compliance certificate posted ­JE]Complies [IF17]2'� with building specifications and DDoes Not compliance path and results. E]Not Observable .1EINot Applicable 303.3 !Manufacturer manuals for % —IC omplies 'mechanical and water heating ElDoes Not systems have been provided. -]Not Observable J, ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: 11219 Old Sound Ave, Mattituck Report date: 05/12/23 Data filename: Page 10 of 10 2021 IECC Energy Efficiency Certificate lnsuls a Above-Grade Wall 0.00 Below-Grade Wall 0.00 Floor 0.00 Ceiling / Roof 0.00 Ductwork(unconditioned spaces): Door Rating Window 0.30 0.31 Door 0.29 0.25 Heating&,Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments E 5- 1 G N 5 ATJD ARCHITECTURE& PLANNING,PC Specification/Product Literature For The Existing Conditions at Robert & Tammy Paladino 11219 Old Sound Avenue Mattituck, NY 11952 May 4th, 2023 P.O.BOX 94I NYS CERTIFIED\ABE CLITCI IOGUF,NY 11935 NYC SBS CULTIFIED WBE PANYNJ CERTIFIED DBE&\\BE C 631943 6501 mia@atjdarch itectu re.com r � 400 SERIES TILT-WASH DOUBLE-HUNG FULL-FRAME WINDOWS ANDERSEN" wlNDows a Dooes Table of Tilt-Wash Double-7Iizes Scale 1/8"(3)m V-0"(305)— tinkers kitchen, Window Dimension '-95/8' 21-15/8' 2'-5 5/8" 2'-7 5/8° 2'-9 5/8" 2'-115/8" 3'-1 5/8° 3'-5 5/8" 3'-9 5/8" (549) (651) (752) (803) (854) (905) (956) (1057) (1159) Minimum 101%a' 2'-21/a° 2'-61/x" i 2'-8 i%a' I '-101/s 3'-01/a" 3'-21/8" 3'-61% 3'-101/s" Rough Opening (562) (664) (765) (816) 1 (867) (917) (968) (1070) (1172) Unobstructed Glass 15" 19- i 23" 25° i 27" 29" 31" 35 39" (lower sash only) (381) (483) (584) 7(635) - (686) (737) (787) (889) _(9_9—1) CUSTOM WIDTHS :45 5/a' � � � � � � N INS Custom-size windows are available 0e � in 1/s"(3)increments. 7W18210 7W20210 TW24210 ti �.�c ntj�Mf• 7W26210 TW28210 TW210210 TW30210 TW34210 ❑TW38210 I L::J1 i=+ TW1832 TW2032 TW2432 I•TW2632_ ' TW2832 TW21032 TW3032 7W3432 7W3832 ■ El El El El ❑ Cottage or reverse cottage sash ratio available for heights shown below in all widths. < VI 1 � CUSTOM WIDTHS—216/e"to 45 11/." 10TW1836 TW2036 TW2436 TW2636 TW2836 TW21036 TW3036 TW3436 TW3836 CUSTOM HEIGHTS-46%e-to 76 T/s- 9Lji0 0 El El El El El El El, I v l TW18310 720310, TW24310 TW26310 TW28310 TW210310 TW30310 TW34310 TW38310 Cottage Reverse Cottage j g � 'y V :m— N , �JJ i ` - - EJ 11 ( j TW1842 TW2042_, TW2442 TW2642 TW2842 TW21042 TW3042 TW3442 TW3842 0 El El B 0 ( !� TW1846 TW2046 TW2446 7W2646 TW2846 TW21046 TW30460 TW34460 TW38460 R v Lo N 0p f {{{j ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ - 4 TW18410 TW20410 TW24410 7W26410 TW28410 TW2104100 TW304100 TW344100 TW384100 F1 I m .- L cN TW1852TW2052 TW2452 TW2652 TW28520 TW210520 TW30520 TW34520 7W38520 E E co , •Qp t :1 E E: ::1 TW-18-56 TW2056 TW2 I5 TW26560 TW28560 TW210560 TW30560 7W34560 TW38560 ", y ' , ❑ ❑ ❑ ❑ ❑ ❑ ❑ anersen indfor windoves/'tiicgttageer + I reverse cotta sash are available at andcrscroslndows.com sidn co 'C' 1:1 :J i i -Window Dimension'always refers to outside 7W18510 7W20510 TW245100 TW265100 TW285100 TW2105100 TW305100 TW345100 TW385100 frame-to-frame dimension. ' , . . . . ■ ■ ■ of building raps,Opening"in pans ons ning, may need to be Increased to allow for use of building wraps,flashing,sin panning, f ! brackets,fasteners or other Items- m •—1 Dimensions In parentheses are In millimeters. tO `o ": m 0 Meet or exceed clear opening area of I 5.7 sq.ft.or 0.53 V.clear opening width F1 F� D of 20'(508)and dear opening height of L I L] TW1862 TW2062 M4620 TW26620 TW28620 TW210620 7W30620 T4620 7W38620 24'(610). W3 conlinued an next page 2021-22 400 Series Product Guide Page 1 of 3 BAY & BOW WINDOWS Table of Double-Hung 30°Angle Bay Window Sizes with Picture Window and 1-8 Flanking Windows Projection 123/4'(324) 12 3/4"(324) 12 3/4"(324) 12 3/4"(324) 12 3/4"(324) 12 3/4"(324) - WIDTHS -- I EEO E[ 11 i. Bay Window 6'-815hs" 7'-015h6 7'-6 s/a" 7'-105/8" Dimension (2056) (2157) (2302) (2403) (2607) (2810) Minimum 6'-81/8° 7'-01/8° 7'-53/4' 7'-93/4" 8'-53/4" 9'-13/4" Rough Opening (2035) (2137) (2280) (2381) (2584) (2788) 4'-21/4" (1276) 4'23%x° (1289) 30-30310-18 30-310310-18 30-42310-1B 30-410310-18 4'-61/4" (1378) — ---- (1 -- -- -- 63 - 30-3042-18 30-3442-18 30.31042-18 30-4242-18 30-41042-18 30-5642-18 4'- /a" 391) 4°-101/4° (1480) MCS 4'-103/4° (1492) 30-3046-18 30-3446-18 30-31046-18 30-4246-18 30-41046-18 30-5646-18 5'-61/4" (1683) 5'-63/4° (1695) 30-3052-18 30-31052-18 30-4252-18 30-41052-18 5'-101/a° (1784) 30-31056-18 30-4256-18 5'-103/4° (1797) 6'-61/4" (1988) 6'-63/4" (2000) 3031062-18 30-4262-18 ^Table of Double-H'ung 30°Angle Bay Window Sizes with Picture Window and 2-0 Flanking Windows Pmjeclion 143/4"(375) 143/a"(375) 143/4"(375) i____ 143%d"(375j 143/4"(375) 143/4"(375) WIDTHS i ------- I. - I d] J E Bay Window 7'-7 7/8" 81-18/161 I W-5 Mx` 9'-1 9hs" 9'-9 8h6" i, Dimension (2232) (2334) (2478) (2580) i (2783) (2986) Minimum T-3" 7'4" 8'-03/4" ; 8'43la" 9'-03/4• 9'-83/4" Rough Opening (2210) (2311) (2457) 1 (2559) ; (2762) (2965) W-21/4" (1276) 30-30310-20 30-310310.20 30-42310-20 I 30-410310-20 4'-61/a" (1378) -- - 30-3042-20 303442-20 3031042-20 30-4242-20 30-41042-20 30-5642-20 4'-63/4° (1391) 4'-101/a" (1480) Co -. - 303046-20 303446-20 3031046-20 30-4246-20 30-41046-20 30-5646-20 In = 4'-103/a (1492) 5'-61/a" (1683) 30-3052-20 30-31052-20 30-4252-20 30-41052-20 5'-101/a" (1784) 3031056-20 30-4256-20 6'61/a" (1988) 6'-63/4" (2000); 30-31062-20 30-4262-20 r , Ordering Prefix: Proper support of projecting bow and bay windows is required,see installation Instructions.Failure to WDH 400 Series WoodwrighV Double-Hung Window do so may result in injury,product or property damage. WPW 400 Series Woodwright Picture Window TW 400 SeriesTiiit-Wash Double-Hung Window DHP 400 Series Tilt-Wash Picture Window •°Projection"refers to outside of the exterior sheathing to the outer edge of the window. •"window Dimension'always refers to outside frame to frame dimension. • "Minimum Rough Opening'dimensions may need to be Increased to allow for use of building wraps,flashing,sill panning,brackets,fasteners or other Items.See pages 210.211 for more details. •One Andersen cable kit,with two cables,is Included with the unit for proper Installation.Each cable supports a maximum load of 500 lbs/227 kg:additional support is necessary for loads exceeding 1000 lbs/454 kg. •Angle bay and bow windows include only the basic unit.Roof and other installation materials provided by other manufacturers. •For walkout angle bay and bow window details and installation guidelines,contact your Andersen supplier. •Dimensions in parentheses are in millimeters. 106 PRODUCT PERFORMANCE v Center of Glass Performance Data for products with Low-E4'SmartSun'Glass For current performance information,please visit andersenwindows.com. g Andersen"Product �----�_' VP � SCz � SHGC' i RHG"- 1 Tu�FaA�o Tdws ®Center' f IGSTa 400 Series Cesement,Awning&TIH-WashDouble-Hung FulliFYame Windows I 66% 0.32 028 66 5% 21% 61% 56°F i 400 Sodas Gilding Window,11a11CImJe,Circle&Oval Windows 66% 0.31 j 027 66 5% 21% 61% 56°F j 400 Series Caseman/Awrfl ng Picture&Tmnsoncs,WoodwdgIXDauble-Hung,Picture&Transom FilFFrame, Woodwdght'Doubla-Hung,Picture&Transom Insert,TRt-Wash Picture&Transom FulUmme,TOt-Wash i 65% 0.31 027 65 5% 21% 61% 56°F Double-Hung,Picture&Transom Insert Windows }400 Series Elliptical Windows,Freaehwood-Hinged Inswing Patio Doors,Fienchrood'Patio Door Sidelights, i 65% 0.31 027 66 5% 21% 61% = 56°F i I SWdlghtTransmns&Transoms i 400 Sodas Frencimood'Gilding Patio Doom I 64% 0.32 027 66 5% 21% 61% 56'F i 400 Series Hallrame,Arch&SpdnMne"Windows I 63% 0.31- 0.27 65 4% a 20% 61% 56'F 1 400 Series Complementary Springune&Arch Hinged Inswing Patio Doors ; 65% 0.31 027 207 5% 21% 61% 56°F Center of Glass Performance Data for products with low-W Glass ; For current performance information,please visit andersenwindows.comli —-- Fading %RH Andersen Product VP' SC' SHGC3 RHG° TmH f Tdws 0Center' IGSTs 1 400 Solas Casematd,Awning&TUbWesh DwWHung Ful Frame Windows f 7396 0.48 0.42 100 17% 34% 61% 56'F 400 Series Gilding Window,Half Circle,Circle&Oral Windows 73% 0.48 0.42 b9- 17% 34% 61% 56'F 400 Series Casemeal/Avmbtg Plebue&Transoms,WoodwrighC Double-Hung,Picture&Transom R&Frm eq WoodwdghP Double-Hung,Picture&Transom Insert,TIH-Wash Picture&Transom FuFFmme,Tilt-Wash .i 72% 0.47 0.41 98, 36% 33% 61% 56°F Double-Hung,Picture&Transom Insert Windows i 400 Series Elliptical Windows,Frenchwood Hinged Inswing Patio Doors,Frenchreod Palo Door Sidelights, 72% 0.48 0.41 98 16% 33% 61% 56°F Sidelight Transoms&Transoms i 400 Series Frenchwood Gliding Patio Doors { 71% 0.47 OA1 98 16% 33% 61% 56'F 40D Series Radham%Arch&Springline Windows i 70% 0.46 0.40 95 14% 31% 61% 56°F J400 Series Complementary Spdnoine&Arch Hinged Inssdng Patio Doors ! 72% 0.48 0.41 310 16% ( 33% 61% 56'F Center of Glass Performance Data for products with Low-E4®Sun Glass For current performance information,please visit andersenwlndows.com. Fading %RH Andersen Product VT' SC SHGC1 RHG' Tuns 1 Tdv� ®Center' IGSTB 400 Series Casement,Awning 8i 111AWash Double flung Full-Frame Windows I 40% 0.30 026 62 17% 25% 61% 56'F ' '400 Series Gliding Window,Half Circle,Circle&Oval Windows ` 40% 0.29 026 62 17% 25% 59% 55°F 400 Series Casement/Awning Picture&Transoms,WoodwrlghC Double-Hung,Picture&Transom Full-Frame, 'Woodwrighe Doublo•Hung,Picture&Transom Insert,IM-Wash Picture&Transom FuNlrame,Tiff-Wash 1 40% 029 025 61 16% 24% 59% - 55°F Double-Hung,Picture&Transom Insert Windows 400 Series Elliptical Windows,Frenehwood Hinged Inswing Patio Doors,Fratchnood Path Door Sidelights, 40% 0.29 } 0.25 61 16% 24% 59% 55°F Sidelight hansoms&Transoms 400 Series Fmnchwood Gilding Patio Doors j 39% 0.29 025 61 15% 23% 61% 56'F 400 Series Heaiframe,Arch&Springline Windows 37% 0.28 024 59 13% 22% 61% 56°F +400 Series Complementary Spdngline&Amh Hinged Inswing Patio Moors j 40% 0.29 I 0.25 - 193 16% 24% 59% 55'F ­Low-EV"Low-E4*Smartsur'and'Low-E4'Sun"are Andersen trademarks for'Low-E'glass. •Based on NFRC testing/slmulation conditions using Windows v7.4.6.0 and NFRC validated spectral data.0°F outside temperature,70'F Inside temperature and a 15 mph wind. 1)Visible Transmittance(VT)measures how much light comes through the glass.The higher the value,from 0 to 1,the more daylight the glass lets in.Visible Transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. 2)Shading Coefficient(SC)defines the amount of heat gain through the glass compared to a single light of clear% (3)glass. 3)Solar Heat Gain Coefficient(SHGC)defines the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released Inward.The lower the value,the less heat is transmitted through the glass. 4)Relative Heat Gain(RHG)is the amount of heat gain through a glazing incorporating U-Factor and Solar Heat Gain Coefficient. 5)Transmission Ultra-Violet Energy(Tuv).The transmission of short-wave energy In the 300-380 nanometer portion of the solar spectrum.The energy can cause fabric fading. 6)Transmission Damage Function(Tdw).The transmission of UV and visible light energy in the 300-600 nanometer portion of the solar spectrum.The value includes both the UV and visible light energy that can cause fabric fading. This rating has also been referred to as the Krochmann Damage Function.This rating better predicts fading potential than UV transmission alone.The lower the Damage Function rating,the less transmission of short-wave energy through the glass that can potentially cause fabric fading.Fabric type is also a key component of fading potential. 7)Percent relative humidity before condensation occurs at the center of glass,taken using center of glass temperature. 8)Inside glass surface temperatures are taken at the center of glass. -This data Is accurate as of February 2019.Due to ongoing product changes,updated test results,or new Industry standards,this data may change overtime.Contact your Andersen supplier for current performance information or upgrade options. •Contact your Andersen supplier or visit andersenwindows.com/nfrc for total unit performance data on windows and patio doors(Including units with patterned glass,tempered glass and glass with capillary breather tubes). 200 PRODUCT PERFORMANCE Andersed NFRC Certifled Total Unit Performance(continued) For current performance information,please visit andersenwlndows.com. Andersen'Product" High-Performance Dual-Pane Glass7ype 1.1-Faction' SHW VTC !Andemetf Product High-Performance Dual-Pane Glass Type(U-Factor'+ SHGCr VF' Without Grilles 0.27 0.34 0.59 WkhoutGdlles 0.30 0.31 0.53 W Simulated Divided Light Gnlles 0.27 0.31 0.53 Simulated Divided Light Grilles 0.30 0.28 0.47 ! o Firelight Gnlles 0.27 0.31 0.53_ o Firelight Grilles 0.31 0.28 0.47 J Full Divided Light Grilles 0.28 0.31 0.53 J Full Divided Light Grilles 0.31 0.28 0.47 WithoutGnlles 0.22 0.33 0.58 WithoutGrilles 0.27 0.30 0.52__ W 15 Simulated Divided Light Grilles 0.22 0.30 0.52 W' Simulated Divided Light Grilles 0.27 0.27 0.46 400 Series i Firelight Grilles 0.22 0.30 0.52 = Firelight Galles 0.27 0.27 0.46 (Casement/Aiming 3 Full Divided Light Grilles 0.24 0.30 0.523 Full Divided Light Gdlles 0.28 0.27 0,46 Wi Picture&Transom '400 Series Woodwdght' thout Grilles 0.27 0.21 0.32 Double-Hung Insert Without Grilles 0.31 0.19 0.29 WUplorrs W Simulated Divided Light Grilles 0.27 0.19 0.29 - Windows w r: Simulated Divided Light Grilles 0.31 0.17 0.26 i `� FnelightGrilles 0.27 0.19 0.29 i AND-N-74 �' FlneligntGdlles 0.32 0.17 0.26 Full Divided Ught Grilles 0.29 0.19 029 Full Divided Light Grilles 0.32 0.17 0.26 Without Grilles 0.26 0.23 0.53 f Without Grilles 0.30 0.21 0.48 _ oSimulated Divided Light Grilles 0.26 0.21 0.48 f w Simulated Divided Light Grilles 0.30 0.19 0.42 e FinelightGrilles 0.26 0.21 0.48 ! i E FinelightGrilles 0.31 0.19 0.42 Full Divided Light Grilles 0.28 021 0.48 ' "' Full Divided Light Grilles. 0.31 0.19 0.42 Without Grilles 0.22 0.22 0.52 Without Grilles 0.26 0.20 0.46 Simulated Divided Light Grilles 0.22 0.20 0.47 W 5 Simulated Divided Light Grilles 0.26 0.18 0.41 9 E x Firelight Grilles 0.22 0.20 0.47 i 5 i Firelight Grilles 0.27 0.18 0.41 Ful!Divided Light Grilles 0.24 0.20 0.47 Full Divided Light Grilles 0.28 0.18 0.41 Without Grilles 0.30 0.30 0.52 WithoutGrilles 0.29 0.32 0.54 ffi Simulated Divided Light Grilles 0.30 027 0.46 i $ Simulated Divided Light Grilles 0.29 0.29 0.48 o Fnel!ght Grilles 0.31 0.27 0.46 9 Finellot"Grilles 0.30 0.28 0.48 - J Ful!Divided Light Grilles 0.31 0.27 0.46 - Full Divided Light Grilles 0.30 0.29 0.48 Without Grilles 0.26 0.30 0.51 WkhoutGrilles 0.25 0.30 0.52 W Simulated Divided Light Grilles 0.26 0.27 0.45 ! w Simulated Divided Light Grilles - - - 5= FinelightGrilles 0.27 027 0.45 I � Finel!ghtGdlles 0.26 0.27 0.47 i 900 Series Woodwdght' 3 Full Divided Ugh[Grilles 028 0.27 0.45 +400 Series Woadwright' 3 Full Divided Ught Grilles 0.27 0.27 0.47 Double-Hung Full-Frame Without Grilles 0.30 0.19 028 Picture Insert Windows Without Grilles0.29 0.20 0.29 i Windowsyam+= Simulated Divided UghtGn!les 0.30 0.17 0.25 ANDN-77 ,�„ Simulated Divided Light Grilles 0.29 0.18 0.26 AND-N-669FinelightGrilles 0.31 0.17 025 `9 FinelightGrilles 0,30 0.18 0.26 Full Divided Light Grilles 0.31 0.17 0.25 Full Divided Light Grilles 0.30 0.18 0.26 { Without Grilles 0.29 0.21 0.47 Without Grilles 0.28 0.22 0.48 Simulated Divided Light Grilles 0.29 0.19 0.42 w Simulated Divided Light Grilles 0.28 0.20 0.43 • - e Firelight Grilles 0.30 0.19 0.42 FinelightGrilles 029 0.20 0.43 Ful!Divided Light Grilles 0.30 0.19 0.42 Ful!Divided Ught Grilles 0.30 0.19 0.43 x Without Grilles 0.26 020 0.46 ! Without Grilles' 0.24 0.21 0.47 ? W Simulated Divided Light Grilles 0.26 0.18 0.41 W rx'n 9Simulated Divided Light G611es - - - i `9 E Firelight Galles 0.27 0.18 0.41 r : SEs Freight Grilles 0.25 0.19 0.42 Full Divided Light Grilles 0.27 0.18 0.41 Full Divided Light Grilles 0.26 0.19 0.42 _Without Grilles 0.28 0.31 0.53_ W!thoutGnlles 0.29 0.33 0.56 w Simulated Divided Light Grilles 0.28 0.28 0.48 Simulated Divided Light Grilles 0.29 0.30 0.50 i - Finelight Grilles 0.29 028 0.48 -9 Firelight'Grilles 0.29 0.30 0.50_ Full Divided Light Grilles 0.29 0.29 0.48 Full Divided Light Grilles 0.30 0.30 0.50 i Without Grilles 0.24 0.30 0.52 - - Sc Without Grilles 0.24 0.32 0.55 } Simulated Divided Light Grilles 0.24 0.27 0.47 w Simulated Divided Light Grilles FinelightGril!es 0.25 027 0.47 1 FinelightGrilles 0.24 0.29 0.49_ 400 Seri'e's Woodwright' 3 Full Divided Light Grilles 0.26 027 0.47 1400 Series Woodwdght' 3 Fu!!Divided Ught Grilles 0.26 0.29 0.49 PictureFull-Frame;-" r% Without Grilles 0.28 0.20 0.29 jTransominsertWindows WithoutGri!!es 0.29_ 0.20 _0.3_1_ Windows w Simulated Divided UghtGrilles 0.28 0.18 026 AND-N-78 - } w�_ Simulated Divided Light Grilles 0.29 0.18 0.27 I Ano-Nt7. -' o�' Fnelight Grilles 0.29 0.17 026 1 g"' Flnelight Grilles 0.29 0.18 _ 0.27_ Full Divided Light Grilles 0.29 0.18 026 • ! Ful!Divided UghtGdlles 0.31 0.18 0.27 Without Grilles 0.27 0.21 0.48 Without Grilles 0.28 0.22 0.50 j _ f Simulated Divided Light Grilles 0.27 0.19 0.43 Simulated Divided Light Grilles 0.28 0.20 0.45 9y FlnelightGrilles 0.28 0.19 0.43 iN FinelightGrilles 0.28 0.20 0.45 Full Divided Light Grilles 0.28 0.19 0.43 - Full Divided Light Grilles 0.30 0.20 0.45 _ Without Grilles 0.23 0.21 0.47 ! _ -Y WithoutGri!!es . 0.24 0.21 _0.49_ ` Simulated Divided Light Grilles 0.23 0.19 0.42 W Simulated Divided Ught Grilles - - - _ Ex Firelight Grilles 0.24 0.19 0.42 FlnelightGril!es 0.24 0.19 0.44_ Full Divided Light Grilles 0.25 0.19 0.42 3 Full Divided Light Grilles 0.26 0.19 0.44 Without Grilles 0.28 0.33 0.57 continued on next page y� Simulated Divided Light Grilles 0.28 0.30 0.51 ' o Firelight Grilles 0.28 0.30 0.51 J Full Divided Light Grilles 0.29 0.30 0.51 Without Grilles 0.23 0.32 0.56 -'Low-E4-SmartSurf°"Low-E4;""Law-E4'Sun'and HeatLock'are Andersen trademarks for"Low-E"glass. Simulated Divided Light Grilles 0.23 0.29 0.50 1)U-Factor defines the amount of heat loss through the total unit in BTU/hr/li The lower the value,the Firelight Grilles 0.23 0.29 0.50 F less heat is lost through the entire product.Window values represent non-tempered glass.Use of tempered 400 Series Woodwrigrt' 3 Full Divided Light Grilles 0.25 0.29 0.50 glass can increase U-Factor ratings.See andersenwindows.com/nfrc for specific performance values.Door j Transom FuD-Frame , Without Grilles -0.28 020 0.31 - values represent tempered glass.2)Solar Heat Gain Coefficient(SHGC)defines the fraction of solar radiation Windom w Simulated Divided Light Grilles 0.28 0.18 0.28 admitted through the glass both directly transmitted and absorbed and subsequently released Inward.The AND-W68 ', # !ower the value,the less heat is transmitted through the product.3)Visible Transmittance(VT)measures how 5 Finelight Grilles 0.28 0.18 0.28 much light comes through a product(glass and frame).The higher the value,from 0 to 1,the more daylight the " Full Divided Light Grilles 0.29 0.18 028 product lets in overthe product's total unit area.Visible Light Transmittance Is measured over the 380 to 760 Without Grilles 0.27 0.22 0.51 • nanometer portion of the solar spectrum. w+� Simulated Divided Light Grilles 0.27 0.20 0.46 •NFRC ratings are based on modeling by a third-party agency as validated by an Independent test lab in ccompliance with NFRC program and procedural requirements. E Firelight Grilles 0.27 0.20 0.46 •This data is accurate as of February 2019.Due to ongoing product changes,updated test results,or new r " Ful!Divided Light Grilles 0.28 020 0.46 industry standards or requirements,this data may change over time.Ratings are for sizes specified by NFRC - Without Grilles 0.23 0.22 0.50 for testing and certification.Ratings may vary depending on use of tempered glass,different grille options, J W Simulated Divided Light Grilles 0.23 0.20 0.45 glass with capillary breather tubes for high altitudes,etc. 3N\ Firelight Grilles 0.23 0.20 0.45 3 Full Divided Light Grilles 0.25 020 0.45 202 ersen And ° Andersen NFRC Certified Total Unit Performance(continued) For current performance information,please visit andersenwlndows.com. i"Andersed Product Hlgh-Performance Dual-Pane Glass Type U-Factor'I SHW + VT' Andersen'Product High-Performance Dual-Pane GlassType U-Factor' SHGC' VT" Without Grilles 0.28 0.30 0.52 - Without Grilles 0.30 0.31 0.53 w Simulated Divided Light Grilles 0.28 0.27 0.46 I. - w Simulated Divided Light Grilles ' 030 028 0.47 Flnellght7 Grilles 029 0.27 0.46 Flnelight"Grilles 031 028 0.47 Full Divided Light Grilles 029 0.27 0.46 Full Divided Light Grilles 031 028 0.47 Without Grilles 024 0.30 0.51 i. Without Grilles 026 030 0.52 "• - i Si LV.� mulated Divided Light Grilles 0.25 0.27 0.45 ., W Simulated Divided Ugh[Grilles 026 027 0.46 t`400 Sides Woodwright• 3= Flnelight Grilles 025 0.27 0.45 ; \ Finelighl Grilles 026 027 0.46 3 Full Divided Light Grilles, 0.26 0.27 0.45 i 3 Full Divided Light Grilles 026 0.27 0.46 Spdngllrre"Single-Hung, � NarrDline'"Comerslon IDt Arch DDublo-Hung Without Grilles 028 0.19 I 029 i AND-N-101 Without Grilles 031 0.19 0.30 , Full-Frame Windows r w Simulated Divided Light Grilles 028 0.17 026 _ w Simulated Divided Light Grilles 0.31 0.17 0.26 AN15-N-111 I oN Flnelight Grilles029 0.17 0.26 Flnelight Grilles ' 0.32 0.17 0.26 Full Divided Light Grilles 029 0.17 0.26 ! - Full Divided Light Grilles 032 0.17 0.26 WithautGrilles 0.26 0.20 0.47 i Without Grilles 030 021 0.48 w c Simulated Divided Light Grilles_ 027 0.18 0.42 3Simulated Divided Light Grilles 0.30 0.19 0.43 I E FnellghtGrilles' 0.28 0.18 0.42 E Flnellght Grilles 031 0.19 0.43 i Full Divided Light Grilles 029 0.18 0.42 " Full Divided Light Grilles 031 0.19 0.43 Without Grilles 024 0.20 0.46 _ -x Without Grilles 026 020 0.47 •w mt', Simulated Divided Light Grilles 024 0.18 0.41 i W Simulated Divided Light Grilles 026 0.18 0.42 E= Flnelight Grilles 0.25_ 0.18 0.41 i E= Finelight Grilles 0.26 0.18 0.42 rn 3 Full Divided Light Grilles 0.26 0.18 0.41 wr 3 Full Divided Light Grilles ' 026 0.18 0.42 --- Without Grilles 0.30 0.31 0.53 1' Without Grilles 031 031 0.54 _ w Simulated Divided Light Grilles 0.30 0.28 0.47 ' W Simulated Divided Light Grilles 031 028 0.48 s Firelight'Grilles 030 0.28 0.47 j FlneligM"Grilles 0.32 028 0.48 -9 _ Full Divided Light Grilles 0.31 0.28 0.42 ? Full Divided Light Grilles 0.32 028 0.48 Without Grilles 0.27 0.30 0.52 WlthoutGdlles 027 031 0.52 Simulated Divided Light Grilles 0.27 0.27 0.46 1 W Simulated Divided Light Grilles 027 028 0.46 Flnelight Grilles, 0.27 0.27 _DAB ! � � 3 i Finelight Grilles 028 028 0.46 1:?400 Series Tilt-Wash ! 3 Full Divided Light Grilles 0.28 0.27 0.46 i 400 Series Tllt•Wash j 3 Full Divided Light Grilles 029 028 0.46 i'Double-Hung Full-Framd• I,Double-Hong Insert, Without Grilles 031 0.19 0.30 i. WilhautGolles 031 0.19 029 WindowsWindows w �! y, Simulated Divided Light Grilles= 0.30 0.17 0.26 Simulated Divided Light Grilles 0.31 0.18 0.26 AND-N-24 6 3 i AND-N-132 c , ----- -• --�-�-- ; y`� Flnelight Grilles 0.30 0.17 0.26 i - �`O Flnelight Grilles 033 0.18 0.26 Full Divided Light Grilles 031 0.17 0.26 - Full Divided Light Grilles. 0.32 0.18 0.26 Without Grilles - 0.30 0.21 0.48 r WithcutGnlles 030 021 0.48 wf Simulated Divided Light Grilles 0.29 0.19 0.42 w„3 Simulated Divided Light Grilles 0.30 0.19 0.43 - 9 E Firelight Grilles 029 0.19 0.42 E Flnelight Grilles 0.32 0.19 0.43 r" Full Divided Light Grilles 031 0.19 0.42 Full Divided Light Grilles 031 0.19 0.43 Without Grilles 026 0.20 0.46 i - Without Grilles 0.27 020 0.47 W r Simulated Divided Light Grilles 0.26 0.18 0.41 w Simulated Divided Ught Grilles 027 0.19 0.42 I E= Flnelight Grilles 027 0.18 0.41 j E s Firelight Grilles 027 0.19 0.42 `r'3 Full Divided Light Grilles 028 0.18 0.41 ; Full Divided Light Grilles 028 0.19 0.42 Without Grilles 0.29 0.33 0.56_ - Without Grilles 029 0.32 0.54 w Simulated Divided Light Grilles _ 0.29 0.30 0.50 i w Simulated Divided Light Grilles 029 029 0.48 i Firelight"Grilles 029 0.30 0.50 FlneligM"Grilles 030 028 0.48 Full Divided Light Grilles 0.31 0.30 0.50 y Full Divided Light Grilles 0.30 029 0.48 Without Gilles 0.25 0.32 0.55 Without Grilles 025 030 0.52 w 9 Simulated Divided Light Grilles" 0.25 0.29 0,49 w Simulated Divided Light Grilles - = FlneligM Grilles, 0.25 0.29 0.49 3= Flnelight Grilles 0.26 027 0.47 i 400 Series Tilt-Wash 3 Full Divided Light Grilles 0.27 0.29 0.49400 Sides Tilt-Wash s Full Divided Light Grilles 027 027 0.47 Picture Full-Frame Without Grilles 0.30 0.20 031 E Picture Insert Windows Without Grilles 029 020 029 Windows i w Simulated Divided Light Grilles 0.30 0.18 0.27_ AND-N-133 w Simulated Divided Ught Grilles 029 0.18 0.26 AND-N-27 `'' Firelight Grilles 0.30 0.18 027 ( "' Flnelight Grilles 030 0.18 0.26 { Full Divided Light Grilles 031 0.18 027i Full Divided Light Grilles 031 0.18 0.26 i Without Grilles , 029 0.22 0.51 Without Grilles 028 022 0.48 Simulated Divided Light Grilles 029 0.20 0.45 t e Simulated Divided light Grilles 028 020 0.43 E Fnelight Grilles 029 0.20 0.45 E Flnelight Grilles 029 020 0.43 Full Divided Light Grilles 0.30 0.20 0.45 Full Divided Light Grilles 030 0.19 0.43 ' Without Grilles ' 0.25 0.21 0.50 _ y Without Grilles' 024 0.21 0.47 .y+ j Simulated Divided Light Grilles 0.25 0.19 0.44 w Simulated Divided Light Grilles - - - ' E x Flnellght Grilles 0.25 0.19 0.44 i E= Flnelight Grilles 025 0.19 0.42 `r'# Full Divided Light Grilles 027 0.19 0.44 rn} Full Divided Light Grilles 026 0.19 0.42 Without Grilles, 0.27 0.32 0.55 continued annext page w Simulated Divided Light Grilles 027 0.29 0.49 �. FineligftrGrilles 027 0.29 0.49 - - Full Divided Ught Grilles 028 0.29 0.49 ! Without Grilles 0.23 0.31 0.54 •^Low-E4-SmartSud7''Low-E4;"Low-E4-Sun"and HeatLocr are Andersen trademarks for'Low-E'glass. y 9 Simulated Divided Light Grilles 023 0.28 0.48 1)U-Factor defines the amount of heat lass through the total unit In BTU/hr/ft?°F.The lowerthe value,the 9= Flnelight Grilles 023 0.28 0.48 less heat is lost through the entire product.Window values represent non-tempered glass.Use of tempered 400 Serres Tilt-Wash 3 Full Divided Light Grilles 025 0.28 0.48 glass can increase U-Factor ratings.See andersenwindows.com/nfre for specific performance values.Door t Transom Full-Frame Without Grilles 027 0.19 0.31 values represent tempered glass.2)Solar Heat Gain Coefficient(SHGC)defines the fraction of solar radiation Windows Simulated Divided Light Grilles 027 0.18 027 admitted through the glass both directly transmitted and absorbed and subsequently released Inward.The AN".76 3' lower the value,the less heat is transmitted through the product.3)Visible Transmittance(VT)measures how g Fnelight Gdlles 027 0.18 027 much light comes through a product(glass and frame).The higher the value,from 0 to 1,the more daylight the Full Divided Light Grilles 0.29 0.18 0.27 product lets in over the product's total unit area.Visible Light Transmittance is measured over the 380 to 760 Without Grilles 026 0.21 0.49 nanometer portion of the solar spectrum. 1w x' Simulated Divided Light Grilles 026 0.19 0.44 'NFRC ratings are based on modeling by a third-party agency asvalidated by an independent test lab in # compliance with NFRC program and procedural requirements. 3 E Fnelight Grilles 026 0.19 0.44 •This data is accurate as of February 2019.Due to ongoing product changes,updated test results,or new Full Divided Light Grilles 0.28 0.19 0.44 1 industry standards or requirements,this data may change over time.Ratings are for sizes specified by NFRC Without Grilles 022 0.21 0.48 for testing and certification.Ratings may vary depending on use of tempered glass,different grille options, W ti Simulated Divided Light Grilles 022 0.19 0.43 glass with capillary breather tubes for high altitudes,etc. e Fnelight Grilles 022 0.19 0.43 Full Divided tight Grilles 025 0.19 0.43 203 Mder"sen a TECHNICAL DATA About the NFRC About the Label The National Fenestration Rating Council(NFRC)is a nonpartisan coalition of professionals whose Look for this certification label on every window and patio door you purpose is to provide fair,accurate and credible energy performance ratings for fenestration products. buy.The NFRC section was designed by the National Fenestration NFRC's membership includes manufacturers,suppliers,designers,specifiers,utility companies, Rating Council to provide accurate information that helps you government agencies and other building industry representatives, promote the energy efficiency of the homes you build.These ratings allow you—and your customers—to measure and compare the Andersen Corporation is a founding member of the NFRC and continues to support its work by providing energy performance of similar products.If the product does not fair,accurate and credible energy performance ratings to consumers and the building indult If you have this label,the NFRC has not verified its claims. have any questions about the NFRC,its program or energy performance ratings,write them at NFRC, 6305 Ivy Lane,Suite 140,Greenbelt,MD 20770,Tel;(301)589-1776 Website:www.nfrc.org Do not remove until final code inspection.Save label for future reference. ENERGY STAR'Certified ini HighlightedCertlfi�ENERGY STAR dons les , Canada a ERIRE 18 Energy Rating(ER)represents"Energy energystargo.ca r Rating'and is a rating used in Canada for product comparison,purposes(the higher - i �I the ER number,the more energy saved r--_�,�4 _ t4 during the heating season). - U.S.i UL — �.da 9edAdCe energirstargov •.�`� ENERGY STAR*Climate Zone Map is based on U-Factor and solar heat gain coefficient W IN DOWO,DO ORO Andersene • criteria for specific ENERGY STAR climate FRC zones within the United States and Canada. Casement Window AND-N-1.01592-00001 The shading of the map shows which climate ru5orcd Fenesoata, Vrryl-Clad Wood Frame,Dual-Pane Law-E SmariSun zone(s)a particular product and glass type is r9 ' Glazing with Argon ®' Product Type:Casement ENERGY STAR certified in. ENERGY PERFORMANCE RATINGS LI-Factor indicates how well a product 11-Factor Solar Heat Gain Coefficient prevents heat from escaping(the lower the p 27 1 1 53 0.21 Solar Heat Gain Coefficient measures how number,the better). (U•SJW) 1wdq well a product blocks heat caused by sunlight ADDITIONAL PERFORMANCE RATINGS (the lower the number,the more it will help Visible Transmittance refers to how much Vsibie Transmittance reduce the use of air conditioning and as a visible light comes through a product(the 0.49 result reduce electrical bills and energy use). closer to 1.0,the more light Is transmitted). M­"Wp�9Wm mtblp Imblmme„MUNFRC FD d—Wd�h40da W= pefimums.NRCrdNpem ddDrN dW.fb dWddM.—hal .dki-enda petepmdudsbe. WRC d,e9 notnxgmmend rndpmOid Dtl 0rc 14ro rtthe$dUt fgdNy PMdudfaem'V f.— DnNdtrremNdmefsl�tlPefudMrpmAldpedaminminbmNtim, - WDMA Hallmark Certification verifies QCT i d.�:i"nn the performance ratings of this product JEI}gyp�A ucenso129-111 Hallman cemned Andersen:n Corporation were tested by an independent testing ww,,.wama.mm 400 Series Casement Window Memdadmstipulates Heibork Ceftat6n w indicated bebw. laboratory and verified by a third-party Rn1He certification program. NWW,CNMS,1MtMWAD-M a,wtcaW 1b1e*1W,1,• Performance Grade(PG)and Test Standards °P.W AWM40YND.h11MABXA44M Dass Lc-PQM-1436 ,1622wn Design Pressure(DP)Ratings M403M PwMem,p,Te DT Pit•,g ZPIn r4W FW40 P, was Pmahab,n�mtaim Rai rine,",:�Pa WnadaiNr Mn6,iufd&ddt=N FL 12496 Glazing: 2.2mm AN outer/2.3mm HS inner Glass Construction used with �p-1-®n�yoamme,emHnduaing this product type efadumd ..vvlivdhU—In me t.10 of Caldmue to mwe mnmr,and methanol,which m km m dm stela or Cdkmia In muse bhth defy "rfpr rep.dt.1W hamh. Fa nom hdtnaamo go t,w,Mf55WamingAm.gw Meda ae,Me CEO O IECC Air hftred.n Req.1—me fO.2 CFM/,q.n..laver. WDMAHelhnwk Cerhfimrim R gmm.C-pr-wtlh HUD UM B.I.U.No.111. •NFRC ratings are based on modeling by a third-party agency as validated by an independent test lab in compliance with NFRC program and procedural requirements. 207 SERVICE MANUAL (Basic Information) CM3212 / KMS0712(x 2)+KMS 1812 SPLIT SYSTEM AIR CONDITIONER Indoor Unit Outdoor Unit CM3212 KMS0712 KMS1812 8526481017300 REFERENCE NO.WM-700699 0 2. SPECIFICATIONS Unit Specifications Outdoor CM321Z Model No. KMS6712,.iM�Igi � Applicable indoor unit Cnoling ................................................................................................. ............................... ...... ............... .................................................................................................................................... ...............I u-n-t-i A+A 2 unit,-A+B 3 units-A+A+B 0 Of indnOr units I unit-A I BTU/h 7,006 17,000 18,600,/18,0()0 14,000 14,000 25,000/25,000 00 32, 0/32,000 ........................................................-......................... .................... ...................... ................. Capacity kw 2.05/2.05 ............ 1"4*.'1'0* 733/7.33- .............. o. Phase,Frequency Hz Single,6! Single,60 Single, Single,60 Single,60 *............................ ....... ...... ................�...........I...................................... .......................I 60 -....................................... .....................I............... Voltage rating V 2301208 230/208 230/208 230/208 2301208 .................................................................................. ..............................................................I....................... .............................................................................................................. ........................... Available voltage range V 187 to 253 to 253................................187 to 253.................................187 to 253.................................187,to 253 ........................................1.............................. ..............187................ .... .......... ....I............................. :..................s iiun'........................................ ....- A 3.3/3.5 67/72 118/126 15.01 ........... ................................................................................................-.................. ..........�.?/9'5 .160 Power input W 7501720 �4 3,400/3,300 Pow.er I fac.tur % 94199 99i99 9, 99! 9 i.99. ................................................................. ....................................... ....... ........ .................... ............... ................ Sterling amperes A 24 56 24x2+56 ................................................................................................................................................................................................ .. ................................................... S.E.E.R. BTU/Wh 10.0/10.0 100/100 10.0110.0 Ran speeds Automatic(2) .............. .........................--...................I........................-................................................................................ ...................................................................................................................... Rulmy, 2/1,4W W...1 ..................... ....................................................--...................................................................................................................................:................................................................................................................................... Refrigerant .........................................................................................................................................................................................In amount charged at shipment lbs.(kg) R-22:1.93 x 2(0.83 x 2)/4.14(1.98) .......... ............................................................................................ Refrigerant control Capillary tube Operation sound(Outdoor unit) dB-A 62' ............. .....................................I................... .........................................I..................................................... ................... ......................... ,Refrigerant tubing connections Flare type ...................................................................... .................................................................................................................................................. ..................*.................................. ......................... ........... Max.allowable tubing length at shipment 33(1 9� .................................................................................................................. Limit of tubing ic'n'g­th' ................................... ...............*.......................... .......7,000'' -B­TU*':''5­0'l1­5*')"1 1'8,000 BTU:65(20) ...............................................................................................-..........................................................................................-...... ........................ .......... .......... ......... ...... Limit of elevation difference ft.t-) between the units .............................................................................. ........... ....................... ............................... ........................... ............................. .................. Narrow tube in,.(mm) 1/4(6.35) Refrigerant tube u.d. ........................................ Wide tube in. 3'18'(9'.'52)*'/"1+8,-O,W+'BTU:1/2-(1,2.7*)' .......................................................... .................................................................................................................. ................................................................................................................. Refrigerant tube kit Optional Height in,(mm) 32-1/16(915) '13 i width ............ ..................... '11131*) ....... ................. -tL Depth In(mm) 26-3/8(670) ................................................:.............................................................................................................................I............ .................................................................... Net .............................. t wei ht lbs.(kg) 220(9) E .................9.....................................................................I................... ................................................................................................... .9 ............................................................................................................................. Shipping volume cu.ft.(cu. 19.5(0.552) ......................................... .................................. .......................................................................................................................... ...........................I............. 242(110) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Remarks: Rating conditions are:Outside air temperature 95°F DB/75°F WB Indoor unit entering air temperature g0oFDB/67'FWB 2 %w-7omg 5/10/23,9:42 PM Masonite 36-in x 80-in Steel Full Lite Right-Hand Inswing Primed Single Front Door with Brickmould Irlsulating Core in the Front D... SHOP THE SPRING SAVINGS EVENT WITH ALL-NEW SPRING DEALS.SHOP NOW> Search Q 0 elivery to Rivuhoad-South Lowo'c Open until PM's 118D01" . _/'�- Prime,Premavw.atylos,arq avoleNtiy mayvary.OwlaalBWres do rotnonoraMnolMdrg.PAeas and avaiaWLryolproduds and eervioesare —.___"_ 1rr�DW�S' wgea io mange wmawnotko.Eroawto m canecte0 wnaoaixaered.ah Lowes rererves Iro rtgrd to revoke ary slated oiler ane h oareet amy onon.Ira—des mondssions bxludag aft en order nae been suhnlucd. yJindows 8 Doors/Exmdor Doom/From Doors Masonite 36-in x 80-in Steel Full Lite Right-Hand Inswing Primed Single Front Door with Brickmould Insulating Core Item#741094 Model g41g94 She,Masanile*'tr**S}v 107 'O $412.00 ■t $391.40 when you choose $691mo suggested 5%savings on eligible OR payments with 6 month puretaseseveryday special#nandng. Learn how ea m Masmuto high-delinigon steel doom feature decorative panel profiles that offer the ultimate security Clear glass design that allows the maximum amount of daylight into your home Dual-pane Low-E tempered glass for energy savings and added safety Common She(w x H) I 36-in x 804n i Right-hand inswing > Pickup It Delivery Options m FREE Pickup O '®Delivery _ AvaOeWe Nearby U-11 Ws In at st Palehoguo Low&s(18,8 A111901 • mJm) • s ® Readv Fnsta Nraby Mao Oelivm Ostbn + Add to Cart • • Got it Installedlog A • • In use lifestyle[mage,accessories net Included W<']01 Easy 3 Free Rotuma Return your new,unused item In-slore or ship it bark to us free of charge.Lem More Here are some similar items... .-ra --a Thorma-Tru Benchmark ThermaTru Benchmark Thomm-Tm Benchmark Thomla Tm Benchmark Tho—Thu Bonchmark Thmma-Tru Doom 364n x 804n... Doom 364n x 804n... Doom 36-in x 80-In... Doom Emerson 364n x... Own 364n x BD4n... Doom 324n ****1638 *****530 *****530 *****399 *****658 *1k><t*t11 $396.00 1534" 153400 1435.00 $396"00 $396"00 +Add to Cart +Add to Cart +Adtl to Cert +Add to Cart +Add to Cart +Add to C. Overview A For instant control of right.heal transfer and privacy,chose from Mamaite'c selection of door tiles with built-in blinds.Sealed Inside tempered safety glass, the blinds are protected from the dust and damage of everyday use.They're also safe for children and pals because they have no exposed cords.Choose from standard blinds-Detweenylass,or triple-pane-insulated bGndsand-grilles between glass to complement your home's style.Featuring high-definition decorative panel profiles,Masonite steel doors provided the ultimate in security,and am perfect for front door or house-lo-garage applications. 6mrt Ctwt https://www.lowes.com/pd/Masonite-Full-Lite-Extemal-Grille-Right-Hand-inswing-Primed-Steel-Prehung-Entry-Door-with-insulating-Core-Common-36-i... 1/4 5/10/23,9:42 PM Masonite 36-in x 80-in Steel Full Lite Right-Hand Inswing Primed Single Front Door with Brickmould Insulating Core in the Front D... • Masonite highdefinifion steel doors lecture decorative pond profiles that ober the ultimate seartiry •Clear glass design that allows the maximum amount of daylight Into your home warranty Guido ra Installation •Dual-pane Low-E tempered glass for energy savings and added safety PDF Manual •A high performance polane core that loam Insulated cothat helps save energy PDF performance •High quali baked an primer that Is ready to paint and helps to prevent rust and conoslon HawTo Manual 15 Use and Cam • Reinforced steel lode plate applied to the latch sldejamb foradded security PDF Mangy - •Double bored for any Installation of handle set and deadbolt lack PDF •Ready to Install dos with vrood frame and brirJunould • It Is not recommended to trim steel or fiberglass exteder doors;any and a8 Weaning fp PropeS Warning voids warranty Label POF CA Residents: 4,Prop 65 Warning(a)r,71 i Specifications 3-Polnt Locking System X Fire Rating WA Actual Depth(inches) 4.5625 For Use with Mobilo X ' Homes Actual Height(Inches) 81.625 'Glass Caming X Actual Width(inches) 1 37.5 Glass Insulation La E Actual width with 37.5 -._--•-_-__._.A_._...,..r_..... . ........ .._... _ . Sidelights(inches) Glass Shop. FWI Inc Brickmould Included Q Glass Style Extemal griP,e CA Residents:Prop 65 Q Prop 65 WARNING(s)- Handing Rght-hand inswing W—ing(s) Handl.Finish NIA(no hands) Coming Finish NIA -"- _____.__.—.�--_�_ Handles)Included X .. Collection Name NIA Hardware Finish Saba m6kel ColoriFnish Family White, CommerolaNRealdontial Residential Hinge Location(Exterior Rightside View) Common Depth Qnchos) 4.5625 Impact Resistance X Common Haight(inches) 80.0 Impact Resistant Glass X Common Slzo(W x H) 364n x 80-in Jamb Width(inches) 4.5525 Common Width(Inches) 36.0 Locking System Included X ---------_- Configuration Single door Loeksat Som Ready for lockset and -- deadboR Core Typo t Insutmingcore+ .___--____, ----- ----' -'-' -- ''- Lowe's Exclusive X Door Style Coastal X Manufacturer ColoNFlnish Primed Dow Stylo Comamporary ® _...".._.-.__ -__..__._._..__..._______.___.__ _... Material Steel Door Style Craftsman Panol Typu Flush Door Style Fannhouso X Prohung Door Q Dou Style Mid Century X Privacy Rating 1 Door Style Modem ` X Rough Opening Height 82.125 (Inches) ' Door Style Rustic X Rough Opening Width 38,25 Do-Stylo TradWonal Q (Inches) Door Style Victorian -- X- _ Sill Finish Mill ENERGY STAR Certified-- �- _ Sill Typo Adjustable Northlcontral Zone Slab Door X i ENERGY STAR Certified Northam Zono UNSPSC 30171500 ENERGY STAR Carl ad ® Warranty '-..-- 5-yearl-iled .. .... So.Zwitral Zone Weatherstripping Included Q ENERGY STAR Ceniflod Southern Zone _..----- __"_--._ Weight(lbs.) 100 Finish Primed Wood Species NIA Fire Rated X Compare Reviews TT4 T?r Tr T57 https./Iwww.lowes.com/pd/Masonite-Full-Lite-External-Grille-Right-Hand-Inswing-Primed-Steel-Prehung-Entry-Door-with-I nsulating-Core-Common-36-i... 2/4 �p MASONITE Open to extraordinary. Wood-Edge Steel Doors Performance based on assembled door units utilizing Masonite door panels,typical door lites,NFRC default wood frame and sills. ENERGY PERFORMANCE RATINGS U-Factor:(Btu/hr-ftp°F)/Solar Heat Gain Coefficient(SHGC) i PRODUCT DESCRIPTION 1/4 Lite 1/2 Lite 3/4 Lite Full Lite j DEFAULT FRAME 5410 int 5900 int 51100 in' >1100 inZ 1 Decorative IG 0.19/0.08 0.23/0.15 0.26/0.20 0.29/0.27 (Glass Type 0)* Decorative IG with LowE/Argon N/A N/A N/A 0.24/0.24 (Glass Type K)* Decorative IG with LowE/Air N/A N/A N/A 0.27/0.24 (Glass Type M)* Blinds Dual Pane Clear N/A 0.26/0.16 0.30/0.21 0.35/0.21 (Glass Type TB)* Blinds Dual Pane LowE N/A 0.23/0.12 0.26/0.17 0.29/0.12 (Glass Type GB)* LowE/Argon Dual Pane 1" * N/A 0.22/0.09 0.24/0.12 0.27/0.16 (Glass Type D) LowE/Argon Dual Pane 1"with Grids N/A 0.22/0.08 0.24/0.11 0.27/0.14 (Glass Type D)* LowE Dual Pane 1" 0.19/0.09 0.23/0.16 0.25/0.21 0.29/0.28 (Glass Type M)* LowE Dual Pane With Grids 1" (Glass Type M)* 0.19/0.08 0.23/0.14 0.25/0.19 0.29/0.25 Clear IG 1/2" (Glass Type T)* 0.21/0.10 0.27/0.19 0.31/0.26 0.36/0.34 T Clear with Grids 1/2" 0.21/0.09 0.28/0.17 0.32/0.23 0.38/0.30 (Glass Type T)* Clear IG 1" 0.21/0.10 0.26/0.19 0.29/0.26 0.34/0.34 (Glass Type T)* Clear IG With Grids 1" 0.23/0.09 0.28/0.17 0.31/0.23 0.36/0.30 (Glass Type T)* LowE Vent Lite N/A 0.23/0.14 0.25/0.19 0.27/0.14 (Glass Type D)* Clear Vent Lite N/A 0.27/0.17 0.30/0.22 0.35/0.30 (Glass Type T)* Flush or Embossed(Opaque) 0.14/0.01 Air Leakage:90.3 cfm/ft2 *See Product Code Structure Test Reportq STN 17001-MM Note:Bold values meet ENERGY STAR Ufactor and SHGC qualification criteria in all 50 states Energy performance values have been established in accordance with International Energy Conservation Code(IECC);LI-factors determined in accordance to NFRC 100&SHGC values determined in accordance to NFRC 200. Based on 2V door unit width or greater(no sidelites). Our continuing program of product improvement makes specifications,design and product detail subject to change without notice. 01/18 O 2017 Masonite International Corporation.All Rights Reserved. No. Revisions Date ± 8 1 '-111" 2 2 ROOF ELECTRICAL INSPECTION REQUIRED UP' N AP ROVED AS NOTED CLOS 00 +, NEW R-15 INSULATION win N O '__ AT KNEE WALLS S2O DATE: BSMT 1 BSMT 2 n _ _ - - - - - - - - - - - - - - - - - - - - - ±16'-32" FEE: BY: NOTIFY BUILDING DEPARTMENT AT 765.1802 8 AM TO 4 PM FOR THE NEW R-21 INSULATION �,_s., CLOS FOLLOWING INSPECTIONS: AT ROOF RAFTERS DN X I. FOUNDATION - TWO REQUIRED - C? — — — — — — — — — — — — — b`" o, bN FOR POURED CONCRETE CN 2x8 BEAM SM > _ 2. ROUGH - FRAMING & PLUMBING No. Issued Date (� O D 3. INSULATION CO r =w n m Key Plan H2O OJBEDRM 3 0 ' O BEDRM 4 ' -II Q= II sM 4. FINAL - CONSTRUCTION MUST NTS � 1 Lam_—_�� BE COMPLETE FOR co. Road UTILITY RM ALL CONSTRUCTIGN SHALL MEET THE Middle ALL ft'UMBING WASTE Z REQUIREMENTS OF THE CODES OF NEW WNTER LINES NEED N - - - - - -- - - - - - - — — — — — — YORK STATE. NOT RESPONSIBLE FOR O ��. .- D DESIGN OR CONSTRUCTION ERRORS. i co OIL O � `� TANK n O +T-9" ±10'-OZ" ±13'-72" +' NEW R-13 INSULATION fi AT INTERIOR BATH 2 ' O�i� ±31'-0" (/ BATHROOM WALLS COMPLY WITH ALL CODES OF additional NEW YORK STATE & TOWN CODES Certification AS REQUIRED AND CONDITIONS OF � May Be Required. BASEMENT)EXIT SUMP ELEC ROOF THRU BILSO itV179TOVGf""NG BOARD 11219 Old SOTHOtD IUVVN TRUSTEES Sound Ave CHIMNEY EXHAUST FLUE ry•�•�•�t� d Pie spur 1 BSMT FLOOR PLAN 3 2ND FLOOR PLAN 14 _ , o 1/4"_ V OCCUPANCY OR USE IS UNLAWFUL aI � Owners WITHOUT, ERTIFICATH Rob ert Paladlno PO Box 635 All exterior lighting ' ns installed replaced or Lu U OF OCCUPANCY p Mattltuck, NY 11952 repaired shall conform W c to Chapter 172 Q t �S a � PLUMBER CER TIF104TION of the Town Code ON LEAD CONTENT BEFORE < A 301 1 CERTIFICAT F '�r OCCUPANCY Phone. 631-767-6034 6034 4 SOLDER jSLD IN WATER SUPPLY SYSTEM CANS 0T EXCEED 14"1 Ot LEAD. Consultant ±6'-3" NEW ENTRANCE STAIRS N LEGEND WINDOW SCHEDULE N +� ALL PLAN ELEME°JTS ARE EXISTING EXCEPT FOR in THOSE SPECIFICALLY CALLED OUT AS NEW is +' WINDOW FLOOR ROOM MODEL#: MANUFACTURER – – – – – – – –– – NEW BAY WINDOW WIDTH HEIGHT COLOR NEW WALL/CEILING INSULATION,SEE DETAIL 1 KITCHEN 400 SERIES #TW2632 DUAL PANE LOW"E" ANDERSEN WINDOWS 2'-8" 3'-5" WHITE 1 BRED AqC, 1 LIVING RM 400 SERIES #T30-4231-20 DUAL PANE LOW"E" ANDERSEN WINDOWS 8'-5" 4'-2" WHITE 810 SECTION DETAIL ���g�\P JEgZ�G�/�O Q o �► SM EXISTING BATTERY SMOKE DETECTOR * - UP BEDRM 2 EXISTING BATTERY OPERATED -� Cn DOOR SCHEDULE c0 SMOKE AND CARBON MONOXIDE ECOR DE OTc9JgTFo E 02 g35 �0�� n, 0 OF NEN LIVING RM x CO Architect O `- SM O FLOOR ROOM DOOR SIZE MATERIAL 2 1 E51 G N5 $ A301 1 REAR ENTRANCE 36"X 80" STEEL FULL LITE WITH INSULATING CORE41.0 ATJD Architecture & Planning, PC A-301 NEW 2X12 MICROLLAM CLOS CLOS SHEETS g BEAM AT WALL OPENING PO Box 944 _ — - - - - - - - - - - - - - - — — — - DN A-101.00 EXISTING BSMT, 1ST & 2ND FLOOR PLANS AND Cutchogue, NY 11935 N Y-A 1 I c0 SCHEDULES (631)-943-6501 A 302 A-201.00 EXTERIOR ELEVATIONS A-301.00 SECTIONS AND DETAILS Project CLOS NATURAL LIGHT AND VENTILATION WORKSHEET �m N SM ROOM FLOOR LIGHT LIGHT VENTILATION VENTILATIO 11219 Old Sound Avenue ®m KITCHEN � x BEDRM 1 (AREA) AREA (SF) (8% REQUIRED) (ACTUAL) (4% REQUIRED) ACTUAL Mattltuck NY 11953 NEW INSULATION,—/ °= oo SEE DETAIL D 1" ` ' Section 141 Block 03 Lot 02 ±15 11- - KITCHEN/ 2 O ±6'-6" B'-�" LIVING RM 382 SF 31 SF 58 SF 15.3 SF 42 SF N +� NO OTHER ROOMS ARE BEING ALTERED IN SIZE,SHAPE, NATURAL LIGHT OR VENTILATION NEW KITCHEN i BATH I Drawing Title MILLWORK AND APPLIANCES I ______ I _ _ _ � __� REF t8�_8" BMT, 1st & 2nd L _ �_ i I� ZONING ANALYSIS FLOOR PLANS & SCHEDULES L__ 11219 OLD SOUND AVENUE, MATTITUCK, NY THESE SETS OF EXISTING r1lDISTRICT: 1000 SECTION: 141 BLOCK:03 LOT:02 Town of Southold CONDITIONS PLANS ARE TO OBTAIN EXISTING BUILDING CONDITIONS NEW WINDOW Mattituck A CERTIFICATE OF OCCUPANCY Drawn By Staff Residence: R-40 H -H 4 4 ITEM REQUIRED/PERMITTED EXISTING/PROVIDED Date 05/11/2023 ZD zo LOT AREA 40,000 SF Min 1 1,21 1 SF Existing, No Change Scale As Noted +. Project No. 2304-02 N N EXISTING DWELLING =833SF All dimensions area approximate and are sub ect to normal +, +, LOT AREA OCCUPIED 20%Max PP 1 BILCO NEW ENTRANCE STAIRS NEW Et 4TRANCE STAIRS TOTAL= 7.4% building variances. The details and information shown here is a good-faith ±8'-0" ±8'-0" representation of the existing built conditions based on visual FRONT SETBACK 50 FT Min 17.4 FT Existing, No Change NEW DOOR observations and conversations with the owner and 39.3 FT+46.5 FT contractor/installer SIDE SETBACK 15 FT Min Existing, No Change 3 2 These plans are an instrument of service and are the property z A 301 A 302 TOTAL SIDE YARDS 35 FT Min 85.8 FT Existing, No Change of the architect. Infringements will be prosecuted. REAR SETBACK 50 FT Min 47FT Existing, No Change Drawing No. E Q 2 1 ST FLOOR PLAN MAX HEIGHT 35' Approx 22-10 1/2" Existing, No Change 011/4"=r-o" O - 101 ,900 w Sheet Information Dwg. 1 of 3 No. Revisions Date No. Issued Date NTS CJdJe Road EXISTING SIDING AND ------------ 0 ROOF SHINGLES ------- ----------- -------- ------------------ ------------- -------- --------- NEW BA WINDOW EXISTING SIDING AND ROOF SHINGLES --------- 11219 Old Sound Ave NEW ENTRANCE STEPS NEW ENTRANCE STEPS NEW ENTRANCE STEPS ---- ----- NEW ENTRANCE STEPS AND DECKING AND DECKING,SEE AND DECKINGAND DECKING Mrd DETAIL B ------------- -- - -- ------- -- ---- -- - - -- -- 0 ---------- Owners HL I GRADE RADE Robert Paladino PO Box 635 Mattituck, NY 11952 Phone: 631-767-6034 SOUTH ELEVATION NORTH ELEVATION 2 Consultant �RED ARC T.O. PLATE A J Edq 0 EL. ±22'-10 1/2" --A _7 7 A- 02 0 T.O. PLATE QOFN _T' 7 F' i Architect T_ T- ESIGf� S ATJD Architecture & Planning, PC PO Box 944 A T.O.2ND FLOOR _7 EL 8 11 Cutchogue, NY 11935 29 A T.O. CLNG HT (631)-943-6501 'IkJ EL. ±8'-1.. Project 11219 Old Sound Avenue Mattituck, NY 11953 ----------- --------- IL Section 141 Block 03 Lot 02 ----- ----- - _ BUILDING ELEVATIONS GRADE —GRADE EXISTING BUILDING CONDITIONS Drawn By Staff NEW KITCHEN WINDOW NEW EXTERIOR DOOR NEW ENTRANCE STEPS NEW ENTRANCE STEPS NEW BAY WINDOW Date 05/11/2023 NEW ENTRANCE STEPS AND DECKING AND DECKING Scale As Noted AND DECKING WEST ELEVATION (REAR) 4 FAST ELEVATION (FRONT) Project No. 2304-02 1/4" V-0' All dimensions are approximate and are subject to normal building variances. The details and information shown here is a good-faith representation of the existing built conditions based on visual observations and conversations with the owner and contractor/installer These plans are an instrument of service and are the property of the architect. Infringements will be prosecuted. Drawing No. I ZrN A- 301 000 Sheet Information Dwg. 2 of 3 No. Revisions Date T.O. PLATE EL. ±22'-10 1/-2" COLLAR TIES ATTIC T.O. PLATE EL. ±16-3-1/2" No. Issued Date / BEDRM 4 K Plan BEDRM 3 BATH 2 / NEN BATT INSULATION, R-21 AT BEDRM 4 Key P a T.O. 2ND FLOOR ROOF RAFTERS AND R-15 AT KNEE NTS Road f / EL. ±8'-11" WALL,SEE DETAIL C –. s n�d&e T.O. CLNG HT B.O. BEAM HT EL. ±7'-1° �--- — — � NEW BEAM AT _ O ENLARGED OPENING SEE DETAIL A 10 NEW BAY WINDOW r _ _ \ / BEDRM 2 BEDRM 1 NEW KITCHEN KITCHEN _ _ \\ BEDRM 1 ii 11219 Old MILLWORK ANDT.O. 1ST FLOOR APPLIANCES EL. 0'-00" -- _- - - Sound Ave GRADE GRADE � d P�j6 Sour BSMT 2 UTILITY RM BSMT 1 BSMT 2 Owners OIL Robert Paladino TANK PO Box 635 Mattituck, NY 11952 Phone: 631-767-6034 1 SECTION 2 SECTION Consultant r D A qc I J E,444) y/J Q -A _= z cSjgT,l,°E 0205) 'k FOF NE\N Architect EDGE OF EXISTING STRUCTURE �SIGI�S ATJD Architecture & Planning, PC CONTINUOUS 4X4 POST PO Box 944 Cutchogue, NY 11935 �-EXISTING (631)-943-6501 2X6 TOP RAIL § m Project I: ANGLE BRACKETS EACH SIDE IX1 BALUSTRADES 11219 Old Sound Avenue t EXISTING COLLAR TIES NEW R-15 INSULATION OPENING RESTRICTED TO<4"O,TYP 2-2x12 LAMINATED VENEER LUMBER BEAM AT EXISTING 2X4 OPENING RESTRICTED TO<6'0,TYP NEW R-21 INSULATION EXTERIOR WALL. 2X4 BOTTOM RAIL ONLY IN LOCATION MattltUCl( NY 11953 1/2"CARRIAGE BOLTS AT RAFTERS I I OF NEW BEAM,SEE 5/4X6 DECK BOARDS NEW WOOD OR RIGID PLANS Section 141 Block 03 Lot 02 COLUMN CAP +1 INSULATION BAFFLE i � GRADE � NEW R-15 INSULATION Drawing Title 2X4 KING STUD EA SIDE •I AT KNEE WALL POST BASE EMBED IN I 1 EXISTING PLATFORM BUILDING SECTIONS CONCRETE(assumed) .1 "rJ- OR 2X8 JOIST 2X4 JACK STUD EA SIDE WITH 3/4"PLYWOOD CONCRETE BASE POST BASE EMBED SANDWICHED AND GLUED AND SCREWED (assumed) IN CONCRETE & DETAILS CONCRETE BASE FASTENERS: SIMPSON SDW WOOD SCREWS 1 EXISTING BUILDING CONDITIONS ALL WOOD FRAMING IS EXISTING ALL WOOD FRAMING IS EXISTING Drawn By Staff DETAIL AT DETAIL AT DETAIL AT Date 05/11/2023 NEW MICROLLAM BEAM SUPPORT NEW EXTERIOR STAIRS AND DECK ^ NEW ROOF INSULATION NEW INSULATION AT EXTERIOR WALL A NTS 1/4•= 1'-0• C 1/4"= 1'-0" D 1/4•=V_0• Scale As Noted Project No. 2304-02 All dimensions are approximate and are subject to normal building variances. The details and information shown here is a good-faith representation of the existing built conditions based on visual observations and conversations with the owner and contractor/installer These plans are an instrument of service and are the property of the architect. Infringements will be prosecuted. Drawing No. A- 302 ,900 Sheet Information Dwg. 3 of 3