Loading...
HomeMy WebLinkAbout49196-Z �o�aS11EfOLK Gy Town of Southold 7/1/2023 P.O.Box 1179 y fi 53095 Main Rd G4� �aSouthold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44246 Date: 7/1/2023 THIS CERTIFIES that the building ALTERATION Location of Property: 1480 Washington Ave Ext, Greenport SCTM#: 473889 Sec/Block/Lot: 40.-5-1.30 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/30/2023 pursuant to which Building Permit No. 49196 dated 5/3/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: hot water heater, (3)mini splits and outdoor condenser to existing single-family dwelling as aapplied for. The certificate is issued to Bumble CR Living Trt of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49196 6/14/2023 PLUMBERS CERTIFICATION DATED Auth rize ignature iiffat� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY N 10 1 i BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49196 Date: 5/3/2023 Permission is hereby granted to: Bumble CR Living Trt 1480 Washington Ave Ext Greenport, NY 11944 To: install new water heater, (3) mini splits and outdoor condenser to existing single-family dwelling as applied for. At premises located at: 1480 Washington Ave Ext, Greenport SCTM # 473889 Sec/Block/Lot# 40.-5-1.30 Pursuant to application dated 3/30/2023 and approved by the Building Inspector. To expire on 11/1/2024. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO-ALTERATION TO DWELLING $50.00 Total: $250.00 Building Inspector oF so�ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 a� sean.devlinCZD-town.southold.ny.us Southold,NY 11971-0959 Q�yMUNT`I,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Bumble CR Living Trt Address: 1480 Washington Ave Ext city:Greenport st: NY zip: 11944 Building Permit#: 49196 section: 40 Block: 5 Lot: 1.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Double Pole Electric License No: 3913ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service X Commerical Outdoor X 1 st Floor X Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt 1 Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water 30A GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser 1 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 2 Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 200A Panel 40 Circuit/26 Used, Daiken Mini Split w/2- Blowers Notes: HW Heater, HVAC & Service Inspector Signature: Date: June 14, 2023 S.Devlin-Cert Electrical Compliance Form a SOGTyOIo I l 1 { � Y• tliPT 4' AVTOWN O SOUTHOLD BUILDING � 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ ]_ PRE C/O [ ] RENTAL REMARKS: �aVje,0 DATEjq& INSPECTOR oF SOUIyo� # # TOWN OF SOUTHOLD BUILDING DEPT. `yco 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CA LKING [ ] FRAMING /STRAPPING [ gFINAL Sf/l7LS' [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: C o i e G ►Ztl�i c DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS m FOUNDATION (IST) 3 ------------------------------------ 3� FOUNDATION (2ND) con z 0 y ROUGH FRAMING& 0 PLUMBING S� ' S l31 11> � c r INSULATION PER N.Y, STATE ENERGY CODE aaa� Ins GoM J C. �• armor FINAL ADDITIONAL COMMENTS a p c 1 p 4(o 23 !i7ec 1 O ISS 0 a � C-e�t RZ � O z x y x e r� b H ��o uFFncx�o� 0 0 TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov �'h01� darty Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT No. Building Inspector: l� NIiIIUII i 023 Applications and forms must be filled out in their entirety. Incomplete MICR 3 0 2 applications will not be accepted. Where the Applicant is not the owner,an SUIWINGIDEPT. Owner's Authorization form(Page 2)shall be completed. tOWN01FS007HO-D Date: OWNER(S) OF PROPERTY: Name:Bumble CR Living-Trust" F�cTM #i000- Project Address: 1480 Washington Ave.Ext, Greenport, NY 11944 Phone#:631-477-0669 Email:rocksea54@a,ol.com Mailing Address: 1480 Washington Ave Ext, Greenport, NY 11944 CONTACT PERSON: Name:Carol B Bumble Mailing Address: 1480 Washington Ave Ext, Greenport," NY 11944 Phone#:631-477-0669 Email:rocksea54 aol.com" DESIGN PROFESSIONAL INFORMATION: Name:Not applicable Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:A-1 State Inc Mailing Address:40 Highfield Rd, Glen Cove New York 11542, United States Phone#:9176154392 Email:718 262 0522 DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition RAlter� � a�tion ❑ ❑ Rep it Demolition Estimated Cost of Project: ❑Other YV'a.J Ic V, r m" t Co')dQnSe $35000 Will the lot be re-graded? []Yes ®No Will excess fill be removed from premises? ❑Yes No 1 PROPERTY INFORMATION Existing use of property: 1 family Intended use of property: 1 family. Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes *No IF YES, PROVIDE A COPY. ® Check Box After,Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code, APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Carol B Bumble ❑Authorized Agent ®Owner Signature of Applicant: <o, Date: 3 3b - a3 STATE OF NEW YORK) S: COUNTY OF 1 • ) CQ ro I RJA m IO� being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above `named, / (S)he is the (� k .1na(f (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this March day of ,20 2 owu otary Public TPA,CEY L. DWYER PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC,STATE OF NEW YORK NO.DIDW6306900 (Where the applicant is not the owner) OU.nLIFIF..D IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,20a10 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 frr��llFfO( c BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD o� y� Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 y�pd �ap� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(csoutholdtownny.gov seand(c�southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: March 28, 2023 Company Name: Double-Pole Electric, Inc. Electrician's Name: Steve Negri License No.: 3913-ME Elec. email:dblepole@aol.com Elec. Phone No: 631 361-6440 01 request an email copy of Certificate of Compliance Elec. Address.: P.O. Box 130 Nesconset NY 11767 JOB SITE INFORMATION (All Information Required) Name: Carol Bumble Address: 1480 Washington Avenue Greenport NY 11944 Cross Street: Phone No.: 631 477-0669 Bldg.Permit#: q q I Cl(0 email: Tax Map District: 1000 Section:40 Block: 5 Lot: 1.30 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 200a Service Up-Grade 40a 220v HVAC Mini Split Circuit 30a 220v Water Heater Circuit Condensate pump gfi outlet Exterior w/r gfi outlet Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑✓ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: 0 YES❑NO Issued On Temp Information: (All information required) Service Size[—&/I1 Ph❑3 Ph Size: 200 A #Meters 98428650 Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑✓ Underground❑Overhead # Underground Laterals 1 F12 H Frame El Pole Work done on Service? Y N Additiorial Information: PAYMENT DUE WITH APPLICATIO �1l� MAY 3 0 2023 "l I23 OL qQ 00 7FIT777-P7,NC31 Yt C- 41 Olt C1 $P . qq1% rL777=:e-"r�j�� •%` FBI BUILDING DEPARTMENT- Electrical Inspector Cj, G�' TOWN OF SOUTHOLD � y 4 Town Hall Annex- 54375 Main Road - PO Box 1179 �'. Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(@r.southoldtownnygov – seandC@southoldtownnygov_ APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: March 28, 2023 Company Name: Double-Pole Electric, Inc. Electrician's Name: Steve Negri License No.: 3913-ME Elec. email:dblepole@aol.com Elec. Phone No: 631 361-6440 El I request an email copy of Certificate of Compliance Elec. Address.: P.O. Box 130 Nesconset NY 11767 JOB SITE INFORMATION (All Information Required) Name: Carol Bumble Address: 1480 Washington Avenue Greenport NY 11944 Cross Street: Phone No.: 631 477-0669 Bldg.Permit#: g q I q 6 email: Tax Map District: 1000 Section:40 Block: 5 Lot: 1.30 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please'Print Clearly): 200a Service Up-Grade 40a 220v HVAC Mini Sp[it Circuit 30a 220v Water Heater Circuit Condensate pump gfi outlet Exterior w/r gfi outlet Square Footage: Circle All That Apply: Is job ready for inspection?: F-1 YES FVJ NO 0 Rough In Final Do you need a Temp Certificate?: FV] YES ❑NO Issued On Temp Information: (All information required) Service SizeI—V11 Ph❑3 Ph Size: 200 A #Meters 98428650 Old Meter# ❑New ServiceE]Fire Reconnect[–]Flood Reconnect[]Service Reconnect[]✓ Underground[]Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? DY N Additional Information: PAYMENT DUE WITH APPLICATIO �� MAY 3 0 2023 (o� �23 anal, 9Q o0 V--e. C- O I V zPAj yRI9C� PERMIT H Address: Switches 1 Outlets GFI's Surface Sconces H H's UC Lts Fans Fridge HW eele Exhaust Oven W/D Smokes DW Mini Carbon Micro Generator ombo����-/� Ia.✓ Cooktop Transfer lw ill 4C AH f( Hood Service 1 Amps Have Usec )pecial: , 9'7 t%¢SVff®f/I'r BUILDING DEPARTMENT-Electrical Inspector ? o TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road-PO Box 1179-Southold, NY 11971-0959 Telephone (631) 765-1802 Temporary Certificate # ! 7Date 5-3o �- 2023 Customer Name 0AYO Zuylbl e— Electrician Name bot&.bl,_-_PDJe Lf c Address 192p WcvSh; Phone (off )_3 1- 44 e-mail e-mail a 13(e— Dle C1 O . CVM Phone License# Size A DO A Phase Overhead Underground X #of Meters Remarks #of Underground Laterals 1 2 New "H" Frame or Pole H P Fire Reconnect Was work done on Service? Y/N Flood Reconnect Old Meter#Nsy a%5o Service Reconnected Application for electrical service equipment is on file with the town of Southold.On the applicant's notification that this installation is complete,the town will conduct a premises inspection of the service equipment. This verification is valid for 90 d he date above. Authorized by , vorwt�< workers' CERTIFICATE OF INSURANCE COVERAGEsrArE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured A-1 STATE INC. 718-262-0522 21 ETHEL STREET VALLEY STREAM, NY 11580 1c.Federal Employer Identification Number of Insured Work Location of Insured (Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,wrap-Up Policy) 113357487 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold-Building Department Town Hall Annex 3b.Policy Number of Entity Listed in Box"1a" 54375 Main Road DBL441109 P.O Box 1179 3c.Policy effective period Southold, NY 11971-0959 02/27/2023 to 02/26/2024 4. Policy provides the following benefits: © A. Both disability and paid family leave benefits. F] B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. M B.Only the following class or classes of employer's employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 3/27/2023 By walG� (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance Carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B, 4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 46,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. D113-120.1 (12-21) I j1111°°°1°11°°111°1 (111111°�21)°111111 Additional Instructions for Form 1313-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1 a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law. The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage (Certificate) to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c, whichever is earlier. This Certificate is issued as a matter of information only and confers no rights upon the certificate holder. This Certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAIN §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand and twenty-one, the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand eighteen, the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (12-21) Reverse EW Wofkers' RK NEW Workers' Compensation yCERTIFICATE OF Boarnsation .NYS WORKERS, COMPENSATION INSUFA- NCE-COVERAGE la.Legal Name&Address of Insured(use street address only) Ib.Business Telephone Number of Insured (71;S i-22 02,-0:5) A-:1 State,.'lne'.- 1 1111161 Sl Ic.NYS U.qenl ploy nient hTsurance er Emplov 'Registrafion. Nuhiber of hisurecl yalley'Stiviiiii.NIX 11,580-3)107 Work.Location I d.Fed6ral Enl_plove�Identification Number of Insured or of Insured(Onll,required if covei-age iss1vt-ifically ,1 limII&I to certain hjcWtio)isin Nefi�York SMW%-i.C.ii j?olicy) Social,S6cn%itv.Nlmllbc'r_ 113357487 2.Nani6 and Addres-s..6f Enfitv Rcqllestina Pra6f ofCov6raae(Entity, 3i.Naive of Insurance,C-arriel. Being Listed as file i7e hificate Hold&) ;Coillillelital Indellillity Co. Town oi'_,SoPih6ld-,B,u_iIdin2 Qcparimeni 36. b..P-oficy'Number of En�titv Lisited in Box I,I c Tk)%-%,ri Hill]Annex'54375 Main Road )62 -01-15 46-S03C P.0 Box 1179 Smithold,NY.11971 3c.Policy effective'period 06/20/22 ;to 06/20/23 �d. 3 Tile Pr6.prielbr.Pirti ers or Executive Off!cc rs are EX-IJ1161kide o if all prinlerquffic6iyiklud.ed) all,excludes)or 6ermin-partners/-officers excluded. This certil'iesil-ml the imurilifucarfier indicated ilbove'hf box,",33" insures the above-in'box I-a"'I'orwor'er,` C6611MIS11tioll Inldffi.116 INC*\\ York S fa -o 11t}e'ilsatiOil Ise tliis forlii,'Ne« I s e tilider Item 3A on the IN FOR NIATI ON PA G E 0 t ly.workers'compensation i iisu r- alice Policy).'Tile licensec) ii',Mt will."Clid tllis'Cellific'-,'Uc ol'Insurariu to ilic-entity li>l6clitNA"o as,(lie. The ifistiruficc carrier hlilshi6tifv the a bc)Vc co rlilic - ( I N\loi�k-6i;s*.C'Ojiii)�if.1,�iti6ii BoakI within 10 days IF pbli��_y is "-ite holder ,I- 'lie canceled due io'llollpiiylllell(o(,:I w0mituns Pr wit.hin-30 IF there are reasons ether,thannorip6,villent.0.I"promillills Thai Call.col lllpolicy breliminate ljlC iljulftj(l 1'1'jlfi 1110 COVC.ril()i;.ilidiCalbd on III iS_Ce.r(i ficille.(These 1166&s 1-li-xv I -,-- I I lifrinifil.) )e Sell )Y re'll.1 ,Z- otlleiNNise.illi§certiri6te is valid for o'ile vear- after"thi§foriii is'apl-)roved I'the hlsijraj16eC;_,i'rriei-oritsli'ceiisCd agent,or I' the the p-oliev exlArafiou dilte'listed iii box"3c­1.-iA1iiclfever is earlier. This certil"icilte.is issued iis if 111-alter,ol,infornialioli only and cont"er-<'no rights upon'the--corlificale. holder. This cortificato,�flues not illelld.'ext6)d 6r alief 1110 CoVerd2C"llf0ilLICLI by tilepolici cliscd.hoirdoes ifcollf'_r a6i,ri"llis orr6ppollsibiliti&s*beyond tll6s0 Lontillned iffthe referenced p6liev This certificate May be usedas 6viclonwo,of w'orker's'Cornponsiftioll W11(rac-I of Ills,111,1111ceonly,Wll-i-Io the inxlet'lying polis) is in P I ease'Note: Upon cancellation of the workers poficy,indifeated oil this forill.1f tile bus,hiess cofithities to lie)e hiiiiiied oh'a iie-Mit..lie6ise or contract is§66d by a certificate holder"the btisfii6s insist Iirovide that certificate h6ld6r with P.new Cerifflica-te of,AVorkers' C79nipeiis'.1tionCoverage or other-authorized proof that the,buslilessis CocomplyingIvitill'ille ifiandafory cover-age ke(jbieeffients of the New'York Stite lVoelifts' Comijefikifioill"aw. Under peiribitV of perjury.I certify that I ifm all authorized repre'sentative or licensed agellif of the hisuraincie- carrier refer,ericed abov-6 mid that the Annied insured hils the coverage as depicted 6n this forill Af)prov'ed by: Todd Brow;(! ,(PrilllflanlCof ilhoilized repi-C.Scilultive or licenced agent of insurance carrier) Apliroved by: -0312 (SiallaILUIL) (Dille) Title: redproselitalive or licensed;i,penl'ofinsurzinco carrier: :(877)23 -4424 Please'Note:Ofiliinsurance carriel sll(itileil'Iiceiseiligeits.iieiltliorize(lioissteForii'C-iO5.2.Ilisii-aieeBrokers are NOT authorized to issue it. �C-I07.2('9-17)' %\m4,%vcb.nV_.d6v MiTek' Component Constructions Job: WRIGHTSOFT p Date: Nov30,2022 Entire House By: MiTek Wrightsoft Project Information, For: 2022-270 Bumble,Centsible House NY 11944 Design Conditions Location: Indoor: Heating Cooling Suffolk Co.Ap,East Quogue(Islip Dd),NY,US Indoor temperature(°F) 70 78 Elevation: 67 ft Design TD(°F) 53 8 Latitude: 40°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 22.3 18.5 Dry bulb(°F) 97 86 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Semi-loose Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HIM Loss Clg HTM Gain ft? Btut rt F ft"FlBtuh Btuw Btuh BVVft� Btuh Walls 12A-Osw:Frm wall,vnl ext,1/2"wood shth,1/2"gypsum board int fnsh, n 195 0.240 0 12.7 2480 4.68 913 2"x4'wood frm,16"o.c.stud a 249 0.240 0 12.7 3167 4.68 1165 S 27 0.240 0 12.7 343 4.68 126 W 264 0.240 0 12.7 3358 4.68 1236 all 735 0.240 0 12.7 9349 4.68 3440 Partitions 12A-Osw:Firm wall,1/2"gyp.bd ext, 1/2"wood shth,112"gypsum board int 198 0.240 0 12.7 2519 2.11 418 fnsh,2"x4"wood frm,16"o.c.stud Windows 2 glazing,clr outr,air gas,vnl frm mat,clr innr, 1/4"gap,1/4"thk:2 glazing, n 30 0.340 0 18.0 541 12.4 371 dr outr,air gas,vnl frm mat,dr innr,1/4"gap, 1/4"thk;6.67 ft head ht a 45 0.340 0 18.0 811 49.9 2245 W 30 0.340 0 18.0 541 49.9 1497 all 105 0.340 0 18.0 1892 39.2 4113 Doors 11 P0:Door,mtl pur core type a 21 0.290 10.5 15.4 323 5.65 119 W 21 0.290 10.5 15.4 323 5.65 119 all 42 0.290 10.5 15.4 646 5.65 238 Ceilings Attic ceiling,asphalt shingles roof mat,r-14 roof ins,r-8 ceil ins, 1/2" 875 0.106 22.0 5.63 4922 4.56 3994 gypsum board int fnsh Floors Rr floor,frm fir, 12"thkns,r-8 cav ins,leaky bsmt ovr,r-14 wall insul 875 0.100 22.0 1.85 1615 0.28 244 Boldldalic values have been manually overridden Wrightsoft- 2022-Dec-20113528 RigFt-Sdte®Uriversal202222.0.05RS000000 Page �C+A ...Greerport,NY11944-improve to Semi-loose.rip Calc=W8 Frort Door faces:SE Owner Bumble CR Living Trust 6� Property address 1480 Washington Ave Ext, Greenport, NY 11944 Scope of Work AO Smith HPTU-50 Air Source Heat Pump, 5MXS48TVJU outdoor condenser+ 18k+12k+9k FTXS wall mount indoor units ASHP (11.1 HSPF, 20.2 SEER,47000 Btu/h, l Outdoor Units) 1 1 1 $18000 (2792/0/15208) Insulation (Area 1): Kneewall, 4 in,Netted Cellulose 1 320 sqft Insulation (Area 2): Rim joist Insulation, 2 in, Closed Cell Foam Insulation (Area 3): Foundation Wall, 2 in, Close Cell Foam Insulation (Area 4):Attic Open, 12 in, Cellulose 1 420 sqft Insulation (Area 5):Attic Floored, 6 in, Dense pack 1 875 sqft Attic Insulation Accessories (Baffles,Soffit Vents,Insulation Damming) Electrical Service Upgrade 11 200 AMP upgrade Fuel Conversion Accessories 1 Oil tank and burner decommissioned and removed COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF �7TROC�fOUGiV�— APPR T0N1N LVED AS NOT G� Sv It PLANNING BOARD DATE: `� �/6D BY:B.P.# l �v T�4USTEES iPl. FEE: �� NOTIFY BUILDING DEPARTMENT AT 765-1802 -8 AM TO 4 PIA FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED �CGUpANCY OR FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING IIJSE IS UNLAWFUL 3. INSULATION 4. FINAL - CONSTRUCTION MUST ,1VITNOUT CERTIFICAT BE COMPLETE FORI C.O. ALL CONSTRUCTION SHALL MEET THE JF OCCUPANCY REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ELECTRICAL �NSRECTION REQUIRED ACORO® DATE'MM1DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE: 0312712023' THIS CERTIFICATE IS ISSUED-AS A-MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER: THIS; CERTIFICATE DOES NOT AFFIRMATIVELY`OR NEGATIVELY AMEND, EMEND OR.ALTER THE'COVERAGE AFFORDED BY. THE POLICIES BELOW: THIS CERTIFICATE'OF INSURANCE DOES NOT CONSTITUTE; CONTRACT.BETWEEN THE ISSUING INSURER(S); AUTHORIZED' REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER:, IMPORTANT: If'the'certificate holder is an ADDITIONAL'INSURED, the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to, the terms and conditions of the policy,.certain policies may.require an endorsement. A statement on this-certificate.does,not confer rights to the, certificate holder in lieu of such endorsement(s) PRODUCER'. CONTACT" CYRIL RAMADAR . NAME: CYRIL.RAMADAR' PHONE :.718 848 4522: ac Nol: 718 848-4560 105-10 LIBERTY AVENUE' Ao RIESS:, CARICOMINSURANCE@AOL.COM OZONE PARK,NYi 1141.7' INSURERS AFFORDING COVERAGE NAIC#' INSURERA: THIRD COAST INSURANCE COMPANY: .10713 INSURED - - INSURER B: A-1 STATE"INC INSURER C: 21 ETHELSTREET INSURER D: INSURER E VALLEY STREAM NY'' 11580 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIESOF INSURANCE,LISTED,BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING'ANY REQUIREMENT, TERM_OR CONDITION OF ANY"CONTRACT OR OTHER DOCUMENT,WITH RESPECT TO WHICH THIS' CERTIFICATE MAY BE ISSUED OR MAY'PERTAIN,.THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED.HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS"AND CONDITIONS OF SUCH POLICIES.LIMITS.SHOWN MAYHAVE BEEN REDUCED BY.PAID CLAIMS. LTR TYPE OF INSURANCE ADDL SUER POLICY EFF POLICY EXP - 'POLICYNUMBER MMIDD MMlOD/YYYY LIMITS' GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED COMMERCIAL GENERAL LIABILITY PREMISES Ea occurrence 100,000' $ CLAIly*-MADE �OCCUR: MED EXP(Any one ersdn $° 5,000 A GLSISTC003083122' 11!0312022- 11/0312023 PERSONAL&ADV INJURY- $ 1,000,000- i GENERAL AGGREGATE $ 2,00,0,000 'GEN'L AGGREGATE LIM IT APPLIES PER: PRODUCTS-COMPIOPAGG S 1,000,000 X POLICY JE CPRO- LOC ,S; AUTOMOBILE LIABILITY, COMBINED SINGLE LIMIT. Ea accident ANY AUTOI BODILY INJURY(Per person)` $: ALL OWNED SCHEDULED' AUTOS, AUTOS BODILY.INJURY(Peraccide,nl) $ NON-OWNED PROPERTY DAMAGE, $, HIRED'AUTOS AUTOS Per acGdent"' - S. UMBRELLALIAB' H,CLAIMS-MADE, OCCUR EACH OCCURRENCE $ EXCESS LIAB, AGGREGATE $ DED RETENTION$" $ WORKERS COMPENSATION, 'wCSTATU- DTH- AND EMPLOYERS'LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE YIN E.L.EACH ACCIDENT' S OFFICERIMEMBER EXCLUDED?" N/A (Mandatory in NH) E:L.DISEASE-EA EMPLOYE 5 If yes,describe under DESCRIPTION OF OPERATIONS below' 'E.L.DISEASE=POLICY LIMIT S DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD,101,Additional Remarks Schedule,If more space is required)` " As per policy coverages and exclusions.., CERTIFICATE HOLDER CANCELLATION SHOULD'ANY OF THE ABOVE DESCRIBED POLICIES BE',CANCELLED BEFORE Town afSouthold-Building Departmelif THE EXPIRATION DATE THEREOF; 'NOTICE, WILL, BE;`DELIVERED, IN Town Hall Annex; ACCORDANCE WITH THE POLICY PROVISIONS. 54375 Main_Road P.0 Box 1179' AUTHOSENTATNE, - South616 NY 11971-0959 ACORD 25(2010/05) ©1988-2010 ACORD CORPORATION.All rights reserved; The ACORD,name and logo are r I red marks of ACORD MiTek' .. Component Constructions Job: WRIGHTSOFT' �H Date: Nov 30,2022 By: MiTek Wrightsoft -rojepthnformaiion For: 2022-270 Bumble,Centsible House NY 11944- Design C 1944 ! - o • eibft Location: Indoor: Heating Cooling Suffolk Co.Ap,East Quogue(Islip Dd),NY,US Indoor temperature(°F) 70 78 Elevation: 67 ft Design TD(°F) 53 8 Latitude: 40°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gdlb) 22.3 18.5 Dry bulb(°F) 17 86 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Semi-loose Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft� BtuMPF tR°FBtuh BtuhV Btuh Btutvft2 Btuh Walls 12A-0sw:Frm wail,vnl ext,1/2"wood shth,1/2"gypsum board int fnsh, n 195 0.240 0 12.7 2480 4.68 913 2'x4"wood frm, 16"o.c.stud a 143 0.240 0 12.7 1813 4.68 667 w 143 0.240 0 12.7 1813 4.68 667 all 480 0.240 0 12.7 6106 4.68 2246 Partitions (none) Windows 2 glazing,clroutr,air gas,vnl fan mat,clrinnr,1/4"gap,1/4"thk:2 glazing, n 30 0.340 0 18.0 541 12.4 371 dr outr,air gas,vnl frm mat,dr innr, 1/4"gap,1/4"thk;6.67 ft head ht a 15 0.340 0 18.0 270 49.9 748 W 15 0.340 0 18.0 270 49.9 748 all 60 0.340 0 18.0 1081 31.1 1868 Doors (none) Ceilings Attic ceiling,asphalt shingles roof mat,r-14 roof ins,r-8 cell ins, 1/2" 438 0.106 22.0 5.63 2461 4.56 1997 gypsum board int fnsh Floors Rr floor,ftm fir,12"thkns,r-8 cav ins,leaky bsmt ovr,r-14 wail insul 438 0.100 22.0 1.85 808 0.28 122 Bold'dalic values have been manually overridden wright90ft- 2022-Deo-201125:28 . Cf� .m,*•­ b..­y­ Right-SLAe®Uriversal202222.0.05 RS000000 Page 2 Greerport,W11944-improve to Semi-loose.rtp Calc=W8 Frort Door faces:SE MiTek' Component Constructions Job: WRIGHTSOFT' p Date: Nov 30,2022 AH 1 By: MITek Wrightsoft Project Information For: 2022-270 Bumble,Centsible House NY 11944_ Desian Conditions Location: Indoor: Heating Cooling Suffolk Co.Ap,East Quogue(Islip Dd),NY,US Indoor temperature(°F) 70 78 Elevation: 67 ft Design TD(°F) 53 8 Latitude: 40°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 22.3 18.5 Dry bulb(°F) 17 86 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Semi-loose Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain W Btuh/PF ftz°FBtuh BtutVV Btuh Btu"2 Btuh Walls 12A-Osw:Firm wall,vnl ext, 1/2"wood shth,1/2"gypsum board int fnsh, a 107 0.240 0 12.7 1355 4.68 498 2'5x4"wood frm,16"o.c.stud s 27 0.240 0 12.7 343 4.68 126 W 122 0.240 0 12.7 1545 4.68 569 all 255 0.240 0 12.7 3244 4.68 1193 Partitions 12A-Osw:Frm wall,1/2"gyp.bd ext,1/2"wood shth, 1/2"gypsum board int 198 0.240 0 12.7 2519 2.11 418 fnsh,2"A"wood frm,16"o.c.stud Windows 2 glazing,clr outr,air gas,vnl frm mat,clr innr,1/4"gap,1/4"thk:2 glazing, a 30 0.340 0 18.0 541 49.9 1497 dr outr,air gas,vnl frm mat,dr innr,1/4"gap,1/4"thk;6.67 ft head ht w 15 0.340 0 18.0 270 49.9 748 all 45 0.340 0 18.0 811 49.9 2245 Doors 11 P0:Door,mtl pur core type a 21 0.290 10.5 15.4 323 5.65 119 W 21 0.290 10.5 15.4 323 5.65 119 all 42 0.290 10.5 15.4 646 5.65 238 Ceilings Attic ceiling,asphalt shingles roof mat,r-14 roof ins,r-8 ceil ins,1/2" 438 0.106 22.0 5.63 2461 4.56 1997 gypsum board int fnsh Floors Fir floor,frm fir,12"thkns,r-8 cav ins,leaky bsmt ovr,M 4 wall insul 438 0.100 22.0 1.85 808 0.28, 122 Boldiilalic values have been manually overridden wrightsoft® 2022-Dec-2011:35:28 .4CCh GreerAa".• -wN.��mw Rigtt-Suite®Uriversal202222.0.05RS000000 Page port,NY11944-improve to Semi-Ioose.rtp Calc=MJ8 Frort Door faces:SE MiTek' Project Summary Job. WRIGHTS®FTDate: Nov 30,2022 �17g1/'G'l�®Ll�E9. By: MiTek Wrightsoft • - Information For: 2022-270 Bumble,Centsible House NY 11 94 Notes: ® - qn information Weather: Suffolk Co.Ap,East Quogue(Islip Dd),NY,US Winter Design Conditions Summer Design Conditions Outside db 17 OF Outside db 86 OF Inside db 70 OF Inside db 78 OF Design TD 53 OF Design TD 8 OF Daily range M Relative humidity 50 % Moisture difference 19 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 30332 Btuh Structure 15973 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30332 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 15973 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-loose Fireplaces 0 Structure 1656 Btuh Ducts 0 Btuh HeatinCoolinCentral vent(0 cfm) 0 Btuh g g Area(ftz) 875 875 Equipment latent load 1656 Btuh Volume(ft3) 7875 7875 Air changes/hour 1.23 0.64 Equipment Total Load(Sen+Lat) 17629 Btuh Equiv.AVF(cfm) 161 84 Req.total capacity at 0.70 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating Input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual airflow 0 cfm Actual airflow 0 cfm Airflowfactor 0 cfm/Btuh Airflowfactor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 BolcKtalic values have been manually overridden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - wr7ghtsoft� 2022-Dec-20112528 RCCAw -numwM RigN-Suite@ Uriversal 2022 22.0.05 RS000000 Page 1 Greerport,W11944-improve to Seml-loosexLp Calc=MJ8 Frort Door faces:SE Job: MiTek• Project Summary Date: Nov3o,2022 - WRIGHTSOFT' AH 1 By. MiTek Wrightsoft Project information For: 2022-270 Bumble,Centsible House NY 11944-- Notes: 1944Notes: Vesign Information. Weather: Suffolk Co.Ap,East Quogue(Islip Dd),NY,US Winter Design Conditions Summer Design Conditions Outside db 17 OF Outside db 86 OF Inside db 70 OF Inside db 78 OF Design TD 53 OF Design TD 8 OF Daily range M Relative humidity 50 % Moisture difference 19 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 14128 Btuh Structure 8599 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14128 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 8599 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-loose Fireplaces 0 Structure 409 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 438 438 Equipment latent load 409 Btuh Volume(ft3) 3938 3938 Air changes/hour 0.95 0.50 Equipment Total Load(Sen+Lat) 9008 Btuh Equiv.AVF(cfm) 63 33 Req.total capacity at 0.70 SHR 1.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating Input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latentcooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual airflow 341 cfm Actual airflow 341 cfm Air flow factor 0.024 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.95 Bold1talic values have been manually ovenidden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -Fp- =ightsoft- 2022-Dec-20113528 CF1 ^..• Rigk-Stale@)Uriversal2022 22.0.05 RS000000 page 2 Greerport,NY 11944-improve to Semi-loose.rtp Calc=MJS Frort Door faces:SE Mirev Project Surma Job: WRICHTSOFT' AH 2 Date: Nov30,2022 By- MiTek Wrightsoft Project Information For: 2022-270 Bumble,Centsible House NY 11 94 Notes: Deslan Information Weather: Suffolk Co.AID,East Quogue(Islip Dd),NY,US Winter Design Conditions Summer Design Conditions Outside db 17 OF Outside db 86 OF Inside db 70 OF Inside db 78 OF Design TD 53 OF Design TD 8 OF Daily range M Relative humidity 50 % Moisture difference 19 gr4b Heating Summary Sensible Cooling Equipment Load Sizing Structure 16204 Btuh Structure 7375 Btuh Ducts 0 Btuh Ducts 0 Btuh . Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16204 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 7375 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-loose Fireplaces 0 Structure 1246 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 438 438 Equipment latent load 1246 Btuh Volume(ft3) 3938 3938 Air changes/hour 1.51 0.78 Equipment Total Load(Sen+Lat) 8621 Btuh Equiv.AVF(cfm) 99 51 Req.total capacity at 0.70 SHR 0.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 292 cfm Actual air flow 292 cfm Air flow factor 0.018 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Bold/italic values have been manually overridden Calculations approved italic to meet all requirements of Manual J 8th Ed. Ad- 0 2022-Dec-2011:3528 ^M•T•• °-•^•-��•^_•� Right-SuteC�Uriversa1202222.0.05RS000000 Page3 Greerport,NY 11944-improve to Semi-loose.rip Calc=MA Frort Door faces:SE MITeliWRIGHTSOFJob: T' Right-JO Worksheet Entire' House Date: Nov 30,2022 By: MiTek Wrightsoft 1 Room name Entire House AH 1 2 Exposed wall 120.0 It 60.0 It 3 Room height 9.0 ft 9.0 ft 4 Room dimensions 5 Room area 875.0 ft2 437.5 W- Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/tz-°F) (Btuh4t2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PPS Heat Cool Gross N/P/S Heat Cool 6 W 12A-Osw 0240 n 12.72 4.68 225 195 2480 913 0 0 0 0 --G 2glazing,droutr, _ 0.340 n 18.02 12.38 ._30 - 0 541 .- 371 0 0 0 0 11 Tj12A-Osw 0240 e 12.72 4.68 315 249 3167 1165 158 107 1355 498 2gla2ing,droutr, 0.340 a 18.02 49.89 45 0 811 2245 30 0 541 1497 11 PO 0290 a 15.37 5.65 21 21 323 119 21 21 323 119 W_.. 12A-Osw _ ,..-_ _ 0.240, s- 12.72 ,. ., 4.68 27 27 343 126. 27 27 .. ._ 343 -,. -.--126 V�! 12A-Osw 0240 w 12.72 4.68 315 264 3358 1236 158 122 1545 569 2 glazing,dr outr, 0.340 w 18.02 49.89 30 0 541 1497 15 0 270 748 11 PO 0.290 w 15.37 5.65 21 21 323 119 21 21 323 119 P 12A-Osw -- 0.240 12.72 _. - 2.11 198 198 2519 - 418 198 .. . 198 .-- 2519 418 C Atticoeilinq,aspha 0.106 5.63 4.56 875 875 4922 3994 438 438 2461 1997 F Rrfloor,fan tlr, 0.100.. - 1.85, _ 0.28 875 875 _ 1615 244 438 -- 438 808 122 - 6 c)AED excursion 0 0 Envelope loss/gain 20943 12446 1 10487 6213 [12 a) Infiltration 9389 737 3641 286 b) Room ventilation 0 0 0 0 Internal gains. Omipants@ 230 3 690 0 0 Appliances/other 2100 2100 Subtotal(lines 6 to 13) 30332 15973 14128 8599 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 30332 15973 14128 8599 15 Ductloads I O% U%j 0 0% 0% 0 0 Total room load 30332 15973 14128 8599 Air required(cfm) I I I 633 633 341 341 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ --t- wri9r+tsoYe 2022-Dec-20112528 ACCA _ Right-Sate®Uriversal 2022 22.0.05 RS000000 Page 1 Greerport,NY-11944-improve to Semi-loose.rp Calc=MJS Front Door faces:SE MiTeli Rs ht-M Worksheet Job: WRIGHTSOFT g Date: Nov 30,2022 EntireHousesy MiTek Wrightsoft 1 Room name AH 2 2 Exposed wall 60.0 ft 3 Room height 9.0 ft 4 Room dimensions 5 Room area 437.5 ftz Ty Construction U-value Or HTM Area (ftz) Load Area Load number (B1uhAtz-9 (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 T 12A-Osv 0.240 n 12.72 4.68 225 195 2480 913 �—G2glazing,droutr, 0.340 n 18.02 12.38 30 0 541 371 12A-Osw 0240 e 12.72 4.68 158 143 1813 667 2 glazing,or outr, 0.340 a 18.02 49.89 15 0 270 748 11 11 PO 0.290 _e 15.37 5.65 0 0 0 0 w 12A-Ow 0.240 s 12.72 4.68 0 0 0 0 121 12A-Osv 0.240 w 12.72 4.68 158 143 1813 667 2 glazing,or outr, 0.340 w 18.02 49.89 15 0 270 748 11 PO 0.290.,w 15.37 5.65 0 0 0 0 P 12A-Osw 0.240 12.72 2.11 0 0 0 0 C Afticceilinq,aspha 0.106 5.63 4.56 438 438 2461 1997. IF Rr floor,frm fir, 0.100 1.85 028 438 438 808 122 _ 6 c)AED excursion 0 Envelope loss/gain 10456 6233 12 a) Infiltration 5748 451 b) Room ventilation 0 0 13 Internal gains: Occupants@ 230 3 690 Appliances/other 0 Subtotal(lines 6 to 13) 16204 7375 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 16204 7375 15 Dudloads 0% 0 0 0 0 Total room load 16204 7375 Air required(cfm) 292 292 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -FtA- wrigFstsoft 2022-Dec-20113528 Aft """" ' Riglt-Suite@Uriversal202222.0.05RS000OOO Page2 Greerport,NY 11944-improve to Semi-loose.rup Calc=MJ8 Frort Door faces:SE MiTeli' Job: WRIGHT5OFT' AH 1t-J®Worksheet ®ate: Nov 30,2022 By: MiTek Wrightsoft 1 Room name AH 1 LIVING/KITCHEN 2 Exposed wall 60.0 ft 60.0 ft 3 Room height 9.0 ft 9.0 ft heaVoDol 4 Room dimensions 17.5 x 25.0 ft 5 Room area 437.5 ftz 437.5 ftz Ty Construction U-value Or HTM Area (ft) Load Area (ftz) Load number (Btuh/tZ09 (Bbh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12A-Osw 0.240 n 0.00 0.00 0 0 0 0 0 0 0 0 L—G 2 glaang,dr outr, 0.340 n 0.00 0.00 - 0.. 0 .. - 0.. 0 ,- - 0 0 0 0 12A-0sw 0240 e 12.72 4.68 158 107 1355 498 158 107 1355 498 2 glazing,droutr, 0.340 a 18.02 49.89 30 0 541 1497 30 0 541 1497 11 t—D 11 PO 0.290 a 15.37 5.65 21 21 323 119 21 21 323 119 W 12A-Osw 0.240 s 12.72 4.68 27 27 343 126 27 27 __ _ 343 126 W 12A-0sw b.240 w 12.72 4.68 158 122 1545 569 158 122 1545 569 E�(p 2 glazing,dr out-, 0.340 w 18.02 49.89 15 0 270 748 15 0 270 748 11 PO 0.290 w 15.37 5.65 21 21 323 119 21 21 323 119 P - 12A-0s;x_ - .. 0240 - , .12.72 .. - .2.11 198 198 2519 418 ...__ 198 198 2519 418 C Atticceilinq,aspha 0.106 5.63 4.56 438 438 2461 1997 438 438 2461 1997 IF Flr ,floor,firm fir, 0.100 --- 1.85 . 0.28 . .438 43.8 808 122--__ 438 438 808 122 6 c)AED excursion 0 0 Envelope loss/gain 10487 6213 10487 6213 12 a) Infiltration 3641 286 3641 286 b) Room ventilation 0 0 0 0 13 Intemalgains: Occupants@ 230 0 0 0 0 Applianceslother 2100 2100 Subtotal(lines 6to13) 14128 8599 14128 8599 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 14128 8599 14128 8599 15 Ductloads 0% 0% 0 0 0% 0% 0 0 Total room load 14128 8599 14128 8599 Air required(cf m) 341 341 1 341 341 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. _ f}d- wrigtitsof'rr^ 2D22-Dec-20113528 „CCA w T' RigIY-Sate@Uriversal202222.0.05RSU00000 Page3 Greerport,W11944-improve to Semi-loose.rtp Calc=NU8 Front Door faces:SE MiTek` Job: WRIGHTSGFT' AH 2-J®V1/®rksheet Date: Nov 30,2022 MiTek W ightsoft By: 1 Room name AH 2 BEDS 2 Exposed wall 60.0 ft 60.0 It 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 17.5 x 25.0 ft 5 Room area 437.5 ft' 437.5 ft' Ty Construction U-value Or HTM Area (ft) Load Area (ftp Load number (Btuh/ft2--°F) (Btu h4t2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V" 12A-Osvv 0.240 n 12.72 4.68 225 195 2480 913 225 195 2,490 913 2 glazing,or outr, 0.340 n 18.02 12.38 30 0 541 371 30 0 541 371 12A-Osw 0.240 e 12.72 4.68 158 143 1813 667 158 143 1813 667 2 glazing,dr outr, 0.340 a 18.02 49.89 15 0 270 748 15 0 270 748 11 D 11 PO 0.290 _e 0.00 0.00 _ 0 _- 0 0 0 0 _ 00 0 W 12A-Osw- 0.240 s 0.00 0.00 0 0 0 0 0 0 0 0 12A-0sw 0.240 w 12.72 4.68 158 143 1813 667 158 143 1813 667 2 glazing,or outr, 0.340 w 18.02 49.89 15 0 270 748 15 0 270 748 D 11 P0, 0.290 w 0.00 0.00 0 0 _ 0 0 0 _ 0 0 0 P 12A-Osw 0.240 0.00 0.00 0 0 0 0 0 0 0 0 C Atbcceilinq,aspha ._ 0.106 5.63 4.56 438 1.438 2461 1997 438 4318 2461 1997 F Rr floor,frm fir, 0.100 1.85 0.28 438 438 808 122 438 438 808 122 6 c)AED excursion 0 0 Envelope loss/gain 10456 6233 10456 6233 12 a) Infiltration 5748 451 5748 451 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@a 230 3 690 3 690 Applianoes/other 0 0 Subtotal(lines 6 to 13) 16204 7375 16204 7375 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 16204 7375 16204 7375 15 Duct loads 0% 0%1 0 0 -0% 0%1 0 0 Total room load 16204 7375 16204 7375 Air required(cfm) 292 292 292 292 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -H+ wr➢gtitsoTt 2022-Dec-2011:3528 "'"""""""""'^"'• Right-StAte®Uriversa1202222.0.05RS000000 ACCA Greerport,NY-11944-improve to Semi-loose.np Calc=MJ8 Front Door faces:SE Page SSMT BSUF Job MiTek Wrightsoft Scale:1 .72 Performed for: Pagel 2022-270—Bumble RioSiitgU2022 MOD5RS000000 W 11944 2022 Deo-M11:35M .-1944-hVorebSanFbm rtp N Outdoor condenser FIRST FL ® 5MXS48TVJU 9K :18K GARAGE LIVING/ KITCHEN BEDS 12K Job#: MiTek Wrightsoft Scale:1 :72 Performed for: Paget 2072-270_Bumble Ric taA3&UrvvwA2a2 220,05RSUOM W 11944 2M-Da-M11:36a) _1944-h-praebSerri-loosen p ATTIC ATTIC Job#: MiTek Wrightsoft Scale:1 :72 Perforvrred for: Page3 2022-270-Bumble Rdt&4D-0UrvvwA2072 220D5RS000000 NY 11944 2MDec-M11:35M _1944-hVo✓ebSw lcos Job Name: Tag# AHRI 202638701 :' , Submittal Data Sheet 5MXS48TVJU 5 Port, 4-Ton Outdoor Heat Pump ------ -- Efficiency SEER EER HSPF COP Non-Ducted 20.2 10.5 11.1 3.9 Ducted 15.3 8.6 8.6 3.2 Mixed 17.75 9.55 9.85 3.5 Performance Cooling(Btu/hr) Rated 47,000 — _® - Operating Range 14°F—115°F Rated Cooling Conditions: Indoor:80°F DB/67°F WB Outdoor:95°F DB/75°F WB Jr)��* Heating(Btu/hr) -' f � Rated 48,500 fri� ^J J i Operating Range 5°F—60°F II Rated Heating Conditions: Indoor:70°F DB/60°F WB _'!NJ 1�r'�J• Outdoor:47°F DB/43°F WB Electrical Complete warranty details available from your local dealer or at 208/60/1 230/60/1 www.daikincomfort.com.To receive the 12-Year Parts Limited System MCA 33.2 33.2 Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California or Quebec. System MFA 35 35 If product is installed in a commercial application,limited warranty Compressor RLA 27 27 period is 5 years. Outdoor fan motor FLA 1.15 1.15 Outdoor fan motor W 84 84 Outdoor Specifications MFA: Max.fuse amps MCA:Min.circuit amps(A)FLA:Full load amps(A) Compressor Hermetically Sealed Swing Type RLA:Rated load amps(A) W:Fan motor rated output(W) Refrigerant R-410A Factory Charge(Lbs) 8.60 Refrigerant Oil PVE(FVC50K) Piping Cooling Heating Liquid(in) '/<x 5 3/8 x 1, H 3,684 H 3,356 Gas(in) %x 2, Airflow Rate(cfm) M 3,029 M 3,138 5/8 x 2 Drain(in) 1 L 2,756 L 1,500 Max.System Piping Length(ft) 262 Sound Power Level(dBA) 52/55 Max.Interunit Piping Length(ft) 98 Dimensions(H x W x D)(in) 34-1/4 x 43-5/16 x 18-1/8 Max.Height Difference—IDU to ODU(ft) 49.25 Weight(Lbs) 216 Max.Height Difference—IDU to IDU(ft) 24.625 Cha rgeless(ft) 131.6 Additional Charge of Refrigerant(oz/ft) .21 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 1 of 12 5MXS48TVJU Dimensional Data 3! �4 TOM 11 C, C �����a�u���� ,.�.M 2-1133.'l 72 Ef�Ox, C !6 0 I V J q 0 ri WC Q 01 f'5 W'J_ R1 �C;- r_-n 5qT, '. cp z g U IC tc 3178)_ la, o :0 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 2 of 12 Optional Accessories Included Part Number Description KEH082A41 Drain Pan Heater KPW082A41 Air Adjustment Grille KKG082A41 Back protection wire net Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 3 of 12 5MXS48TVJU Capacity Tables DA Non- Ducted, 60 Hz, 208-230V Cooling Capacity of each indoor unit Combination of indoor Each Capacity Total Indoor Unit Capacity unit A room B room C room D room E room Rating (min-max) 07 7.00 - - - - 7 8.90 8,90 3,30-14-00 099.00 - - - - 9,00 3,40-12,00 11,50 11.50 3.40-18.10 12 12.00 - - - - 12. 0 4.20-16.00 15-30 15.30 3.50-24.10 15 - - - - 001 19,20 19,20 18 18.00 - - - - 18-00 5.00-24.00 23.00 23.00 3.60-36.10 24 24.00 24.00 27.40 4 4.70-42,20 07+07 7.00 7.00 - - - .7 8.95 8.95 17.90 3,60-28.10 07+09 7.00 9.00 16.00 5.00-21.30 8.93 ] 7_ 07+12 ,73 14.97 23.70 07+15 7.00 15.00 - - - 22.00 6.50-27.70 8.24 17. 6 25.90 4.80-40.20 07+18 7.00 18.00 - - - 25.00 7.90-30,40 .7.87 20.23 26,50-43,30 07+24 7.0024.00 - - - 31.00 8.00-35.90 2 25.08 4 4 09+09 9.00 9.00 - - - 18.00 5.00-24.0 11.50 11.50 23.00 3.60-36.10 09+12 9.002 - 21.00 5.10-26,80 10.90 14.407 2 09+15 9.00 15.00 - - - 24.00 7.90-29.50 10.28 17.13 27.40 6.50-42.20 09+18 .00 18.00 - - - 27. 0 7.90-32.30 9.83 7 2 6,50-45.30 09+24 9.00 24.0033.00 8,00-37,80 9.25 24,65 - - - 4 12+12 12.00 12.00 - - - 24.00 6.10"29.50 13.70 13.70 27.40 4.80-42.20 12+15 00 00 00 7' 90-32.30 13.11 16. 29,50 6.50-45. 12+18 12,00 18,00 - - - 30.00 7 12.68 19.02 31.70 6.50-48.40 12+24 12. 0 24.00 - - - 36.00 8.10-40.50 12.20 24.4 6,60 6.50-54.50 15+15 1 1S.00 - - - 30,00 8.20-35.00 15,85 1 .70 6,60-48.4 15+18 15.00 - - - 33.00 8.20-37,80 15.41 18.49 33. 0 6.60-51.40 15+24 15. 0 24.00 - 39.00 8.30-43.10 15.23 24.37 4 18+18 18.00 00 - 36.00 9.20-40.50 - - 1 6.60-54,50 18+24 18.00 24.00 - - - 42.00 8.30-45.60 18.26 24.34 42.60 6.60-56.30 24+24 23.50 23.50 - - - 47. 8.30-48.20 24.25 24.2548,50 6.60-58.00 7,00 TOO 7.00 21.00 5,50-26.80 07+07+07 .40 8.40 8.40 25.20 3.70-39.20 07+07+09 7.00 7.00 9.00 23.00 6.50-28.60 8.10 8.1026.60 4 1.2 07+07+12 7 1 - - 26.00 7.90-31.30 7.75 7.752 6.50-44.30 07+07+15 7.00 7 - - 29.00 8.20-34.10 7.48 7.48 16. 3 31. 0 6.60-47.30 07+07+18 7.00 7.00 18.00 - - 32.00 .20-36.80 7.26 7.26 18.68 33,20 07+07+24 7,00 7.024.0038.00 8,30-42.20 7.11 7.21 24.38 38,60 6.60-55.10 07+09+09 7.00 9.00 9.00 - - 25.00 6.SO-30.40 7 2 07+09+12 00 00 - - 28.00 8,00-33.20 7.58 9,74 12.99 30.30 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 4 of 12 5MXS48TVJU Capacity Tables Cooling Capacity of each indoor unit Combination of indoor Each Capacity Total Indoor Unit Capacity unit A room B room C room D room E room Rati ng (min-max) 07+09+15 7 15.031.00 8,20-35.90 0 7,32 41 1 .40 6,60-49.4 07+09+18 7.00 9.00 18.00 34.00 8.20-38.70 7.12 9.16 18.32 34.60 6.60-52.50 07+09+24 7'00 00 4 - - 40,00 8.30-43,90 07+12+12 7.00 12.00 12.00 - - 1.00 8.00-35.9 7.32 12.54 12. 4 - 32.40 6.50-49.40 07+12+15 7.00 12.00 15. 0 34.00 8.20-38.70 2 12.21 1534-60 6.60-52,50 .26 07+12+18 00 00 37.00 8,20-41.40 7,11 12.19 18.29 37,60 07+12+24 7.0012.00 24.00 43.00 8.30-46.50 7.08 12.14 24 8 - 43.50 6.60-56,50 07+15+15 7 1 - 37,00 7.11 15,24 1 07+15+1815.00 00 00 - - 40.00 8,30-43.90 7.11 15.23 18.27 40.60 6.70-55.70 07+15+24 7.00 15.00 24.00 - - 46. 0 8.30-48.20 7.08 15.16 24.26 - 46.50 6.70-57.40 07+18+18 7.00 18.00 18,00 43.00 8,30-46.50 7 18,21 1 07+18+246.71 7.223.02 - - 47,00 8.30-48,20 6 17.82 23.76 - 48.50 6.70-58.00 07+24+245198 47.00 8,30-48,20 6,17 21,16 21,16 48.50 7 "58.00 09+09+099.00 00 - - 32.30 6,50-45,30 09+09+12 9.00 9.00 12.0 30.00 8 35.00 9.51 1 9.51 12.68 - 31.70 6,50-48.40 09+09+159.00 - 33.00 8,20-37.80 9.25 9.25 1 - _ 6,60_S 09+09+18 9.00 91001 - 36.00 8.20-40.50 9.15 9.15 18.30 36.60 6.60-54.50 09+09+24 .00 9.00 24.00 42.00 8.30-45.60 9.13 9.13 24. 2 09+12+12 9. 2 1 - - q 95 12.33 1 33.90 6,60-51.40 - 09+12+15 9.0012.00 1 - - 36.00 8,20-40,50 9.15 12.20 15.25 - 36.60 6.60"S4.50 09+12+18 9,0012.00 1 - - 39.00 8.20-43.10 9.14 12,18 18.28 - q 09+12+249.00 4 - 45.00 8.30-48.20 12.13 24. 7 - 4 6,60-57.10 09+15+15 9.0015.00 15.00 - - 9. 8.30-43.10 9.14 1 .2 3 - - .4 09+15+18 9100 15,001 - - 42.00 8.30-45.60 9.13 15.21 1 - 42.60 .7 09+15+24 8181 14.69 23.50 - - 4 48.20 9.09 15.16 24.25 - 48.50 6.70-58.00 09+18+18 9 18. 0 18. - - 45.00 8.30-48.20 19.20 1 - 4 7.1 09+18+24 8.29 16.59 - - 4700 8.30-48.20 8.56 7. 09+24+24 7.42 19.79 19.79 - - 47. 0 8.30-48.20 7.66 20.42 20.42 - - 48.50 6.70-58.00 12+12+12 12.00 12.0012 - - 12.20 12,20 12. - - 3 ^ 14 10 12+12+15 2•00 12-00 15.039,00 8,30-43.10 0 1 1 12.18 1539.60 6.60-55.40 .23 12+12+18 12,00 12.00 18.00 .00 8,30-45.60 2.17 12.17 18.26 - - 42.60 6.60"56.30 12+12+24 11.75 11,75 - - 47.00 8,30-48.20 12.13 12,13 24.25 12+15+15 12.00 - - 42.00 12.17 15.21 15.21 - - 42.60 6.70-56.30 12+15+18 12.00 - 45.00 8.30-48.20 - 12,13 1 - - 45-50 6,70-57, 12+15+24 2 - - 47 -48. 1 1 2 - - 4 .7 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 5 of 12 5MXS45TVJU Capacity Tables I DA Cool ing Capacity of each indoor unit Combination of indoor Each Capacity Total Indoor Unit Capacity unit A room B room C room D room I E room Rati ng (min-max) 12+18+18 11.75 17 17.63 - - 47.0 .30' .2 12.13 18.19 18.19 48.50 6.70-58.00 12+18+24 •44 15.67 20.89 - - 47.00 8.30-48.2 10.78 16.17 2 49.50 6.70-58,00 15+15+15 15.00 - - 45.00 8,20-48.20 15.17 15.17 15.17 .1 15+15+18 14.69 14.69 17.63 - - 47.00 8.20-48.2 15.16 15.16 18.19 48.50 6.70-58.00 15+15+24 13.063 - - 47.00 -4 . 13.47 1147 2 48,50 6,70-58.00 15+18+18 13.82 1 - 47.00 8,20-48.20 14.26 17.12 17. 2 48.50 6.70-58.00 15+18+24 12.37 14. 4 19.79 - - 47.00 8.10-48.20 12.76 15.32 20.42 48.50 18+18+18 7 15.67 .6 - 47,00 8,20-48,20 17 17 17 07+07+07+07TOO 7.00 7.00 7. 0 - 28.00 8.20-33.20 7.58 7.58 7,58 7.58 30.30 6.60-46.30 07+07+07+09 7.00 7 30.01) 8,20-35.00 7.40 7.407.40 9,51 31.70 6,60-48.40 07+07+07+12 7.00 7.00 7.00 12. 0 - 33,00 8.20-37,80 7.19 7.19 7.19 12. 3 33.90 6.60-51.40 07+07+07+15 7.00 7.00 7,00 15.00 - 36.00 8.30-40.50 7.12 7.12 7.12 15.25 36.60 6.70-54.50 07+07+07+18 7.007 7 .11 7.11 18.28 39.60 6.70-55.40 07+07+07+24 00 00 24 - 45.00 8,30-48.20 7.08 7.08 7,08 24.27 45.50 6.70-57.10 07+07+09+09 7.00 7.00 9.00 9.00 - 32.00 8.20-36.80 7.26 7.26 9.34 9.34 33.20 6,60-50.40 07+07+09+12 00 00 00 - 00 0 7,12 7.12 9.15 12.21 35.60 6,60-53,50 07+07+09+15 7.00 7.00 9.00 15.00 38.00 8.30-42.20 7.11 7.11 9.14 15.24 38.60 6.70-55.10 07+07+09+18 7.00 7.009.00 18.00 - 41,00 8,30-44.80 7.10 7. 18.26 1 07+07+09+24 7.00 7.00 9.00 24.00 4 7,00 8,30-48.20 7.07 7.07 9.10 24.26 47.50 6.70-57.70 07+07+12+12 7.00 7.00 12.00 12.00 38.00 8.30-42.20 7.11 7,11 12.19 12,193 .1 07+07+12+15 7. 41.60 6.70-56.00 07+07+12+18 7 7.00 12.00 1 . - 44.00 8,30-47,3 7.08 7.08 12.14 18.20 44.50 6,70-56.80 07+07+12+24 6.58 6,5811.28 22. 6 - 47.00 8.30-48.20 6.79 6,79 11,64 23.28 48.50 6,70-58.00 07+07+15+15 7,00 7.001 - 44,00 8.20-47,30 7.08 7 1 44.SO 6.70-56.80 07+07+15+18 7.00 7.00 15.00 18.00 47.00 8.20-48.20 7.07 7.07 15.16 18.19 47.50 6,70-57.70 07+07+15+246,21 212 - 47.00 8.10-48.20 6,41 6,417 21.96 48,50 .7 - 0 07+07+18+186.58 2 - 478,20-48.20 6,79 6.79 17.4617,46 48.50 .7 0 07+07+18+24 5.88 5.88 15.11 20.14 47.00 8.10-48.20 6.06 6.06 15.59 20.79 48.50 6,70-58.00 07+09+09+09 TGO 00 00 - 34.00 2 12 07+09+09+12 7.00 9.00 9.00 12-00 - 37.00 8.30-41.40 7.11 9.15 9.15 12.19 37.60 6.60"54.80 07+09+09+15 7 - 40.00 7.11 9.14 9.14 15,23 6,70-55.70 07+09+09+18 .0 18.00 - 4 5 7.08 9.10 9.10 .2 43.50 07+09+09+24 6.71 8.63 8.63 23.02 47.00 8.30^48.20 6.93 8.91 8.91 23.7648.50 6.70-58.00 07+09+12+12 TGO 9.00 12.00 - 40.00 8,30-43.90 1 9,14 12,1 "140.60 6,60-55.70 07+09+12+15 ".0015. 0-46.50 1 16.70-56.50 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 6 of 12 51ViXS48TVJ U Capacity Tables Cooling Capacity of each indoor unit Combination of indoor Each Capacity Total Indoor Unit Capacity unit A room B room C room D room E room Rating (min-max) 07+09+12+18 - 46,00 9.30-48,20 7.08 9,10 12,13 18,20 - 46.50 .4 07+09+12+24 6. 3 8,13 JO-852 47.00 8.30-48,20 6.53 8.39 11.19 22.3 - 48.50 6.70-58.00 07+09+15+15 7.00 9.00 15.00 15.00 - 46.00 8.20^ .20 7 9.1 1 - 6.70-57.40 07+09+15+18 6,7114.39 17.27 - 47 8.20-48,20 6.93 8.91 14. 48.506.70-58.00 07+09+15+24 5.98 7.69 12.82 20. 1 - 47.00 8.10-48.20 6.17 7.94 13.23 21.16 - 48.50 6.80-58.00 07+09+18+189.13 16.27 - 478.20-48,20 r 53 8.39 16.79 16. - 48,50 6.70-58.00 07+09+18+24 5.67 7.29 14.59 19.45 47,00 8.10-48. 5.85 7.53 15.05 20.07 - 48.50 6.80-S .0 07+12+12+12 .00 12.00 12.00 12. 0 - 43.00 8.30-46.50 7.08 12.14 12.14 12,14 43.50 6,70-56.50 07+12+12+15 7.002 - 46,00 8.30-48.20 7.08 1 2.1 6.70-57,40 07+12+12+18 6.71 11.51 11-51 17,27 - 47.GO 8,30-48.20 6.93 11.88 11.88 17. 2 - 48.50 6.70-58.00 07+12+12+24 5.98 10.25 10.25 20.51 - 47.00 8.30-48.20 6,1.7 1 48.50 6,70-58.00 07+12+15+15 6.71 11.514. 4. 47,00 6.93 it,88 14,85 1 48.50 6,70-58.00 07+12+15+18 6.3310.85 13.56 16.27 - 47. 0 8.20-48.20 6.53 11.19 13.99 16.79 48.50 6.70-58,0 07+12+15+24 5,679,72 12.16 19.45 - 48,10-48,20 5.85 7 7 48-50 6.80-58.00 07+12+18+18 5.98 10,251 15.38 - 478.20-48.20 6.17 10. 8 15.87 15.87 - 48.50 6.80-58.00 07+15+15+15 6.33 13,56 13.56 13.56 47.00 7,90-48.20 6.53 13.99 13.99 13,99 4R.SO 6.90-58.00 07+15+15+1 r,98 2 12.82 15.38 47.00 7.90-48.20 6.17 13.23 13.23 15,87 48.50 6.80-58,00 07+15+18+18 5.67 12.16 14.59 14.59 47.00 7.90-48.20 5.8s 12.54 15. 5 15. 5 - 48.50 6.80-58.00 09+09+09+099.00 00 - 36,00 8,30-40,50 09+09+09+129.00 0 12. - 8,30-43,10 .14 .1 12.1 q 09+09+09+15 9.OD 9.00 9.00 15.00 - 42. 0 8,30-45.6 9.13 9.13 9.13 15.21 - 42. 0 6,70-56.3 09+09+09+189,00 00 1 45,00 8,30-48.20 9.10 9,10 9.10 18.20 - 4 6.70-57.10 09+09+09+248,29 29 2 - 478,30-48.20 9.56 8,56 . 6 22.82 - 48.50 6.70-58.00 09+09+12+12 9100 9.00 12.00 12.00 - 42.00 8.30-45.60 9.13 9,13 12.17 12. 7 - 42.60 6.70-5630 09+09+12+15 9.00 9.00 12.0015.00 - 45.00 8.30-48.20 9.10 9110 1 13 15,17 45.50 6.70-57,10 09+09+12+18 8.81 8.81 11.7517• - 47.00 8.30-48.20 9.09 9.09 12.13 18.19 - 48.50 6.70-58.00 09+09+12+24 7.83 7.83 10.44 20.89 - 47.00 .30-48 2 8,08 9.08 10.78 21.56 - 48.SO 6,70-59.00 09+09+15+15 14.6947.00 8,20-48.20 9.09 09 15.16 15.1 - 48,50 6.70-58,00 09+09+15+18 8.29 8.29 13.8 16.59 47.00 8.20-48.2 8,56 8.56 14.26 17.12 48.50 6.70-58,00 09+09+15+24 7.42 7.42 12.37 19,79 47.00 8.10-48.20 7 12.7 20.42 48.50 09+09+18+18 7 7 15.67 - 47.00 8.20"4R.20 8.08 8.08 16.17 16.17 - 48.50 6.80-58.00 09+12+12+12 9.00 12.00 12.00 12.00 - 45.00 .30-4 .20 12.13 12 13 4 09+12+12+15 8.81 11,75 11-7514 - 9,09 1 .1 15.16 09+12+12+18 15 - 47.00 8,30-48.20 111-041, 11,41 17.12 - 4 09+12+12+2442 89 - 11 20,42 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 7 of 12 5MXS48TVJU Capacity Tables / l Cool ingCapacity of each indoor unit Combination of indoor Each Capacity Total Indoor Unit Capacity unit A room 8 room C room D room E room Rating (min-max) 09+12+15+15 8,29 11.0613.82 2 7 .2 -4 8,56 11,41 14.26 14.?G48.50 6.80-58-00 09+12+15+18 3 10,44 13.06 15. 7 - 47.00 8.20-48.20 8.08 10,78 13.47 16.17 48.50 6.80-58-0 09+12+18+18 7.42 9.89 14,84 14.84 - 47.00 8.20-48,20 7.66 10.21 1S.32 12 4 . 6,80-58,00 09+15+15+157.83 06 1 - 47.00 7,90-48.20 8.08 13.47 13.47 13.4 48.50 6,80-58.00 09+15+15+18 .42 12.37 12.37 14.84 - 47 7.90-48.20 7.66 12.76 12.7615,32 12+12+12+12 1 .75 11.751. 11. - 47. 00 8.30-48.20 12.13 12,13 12,13 12,13 - 48.50 6,70-58,00 12+12+12+15 11.06 11.06 11.06 13.82 1 - 47.00 8.30-48. 20 11.41 11.41 11.41014.2648. 0 6.70-S .012+12+12+18 10. 4 10.44 1 .44 7 - 47.00 8.30-48.20 10.78 10.7 .7 - .7 - 12+12+15+15 .44 .0 2 -48,2010.78 10.78 7 48,50 6,80-58,0012+12+15+18 89 12. 7 4 - 47 8.20-48,20 10.21 21 12.76 15,32 48,50 6,80-58.00 12+15+15+15 9 7 12.37 12.37 - 47.00 7.80-48.20 10.21 12.7612.76 7_.7 49.50 6,80-58-00 - 07+07+07+07+07 00 00 00 7.00 7 7. 2 7.12 7.12 2 7,12 35,60 6.70-53.50 07+07+07+07+09 7.00 7.00 7.00 7.00 9.00 37.00 8.30-41.40 7.11 7,11 7.11 7.11 9.15 37,60 6,70-54.80 07+07+07+07+12 7,00 7.007.00 7.00 12.00 40.00 7.11 7.11 7.11 12.18 -S 7 07+07+07+07+15 7.00 7.00 7.00 7.00 15.00 43.00 8.20-46.50 7.08 7,08 7.08 7.08 15.17 43.50 6.70-5 .5 07+07+07+07+18 7,007 00 00 00 46.00 .2 0-48.20 7.08 7.08 7.08 7.09 18.20 46,50 6.70-57.40 07+07+07+07+24 33 33 33 33 69 7 6.53 6.53 6.53 6.53 226.80-58,00 07+07+07+09+09 7.00 7.00 7.00 9.00 9.00 39.00 8.30-43.10 11 7.11 7.11 9.14 9.14 39.60 6.70-55.40 07+07+07+09+12 7 7.00 7' 42. 8.30-45.60 9.13 12. 7 42.606.70-56,30 07+07+07+09+15 7.00 7,00 7.00 9.00 15,00 45.00 -4 . 20 7.08 7.08 7.08 9.10 15.17 45.50 6.80-57.10 07+07+07+09+186.85 85 81 17.63 47.00 20^ 48.20 7. 7 7. 7 7.07 9.09 1 48.50 6.80-58.00 07+07+07+09+24 09 09 6.09 7 8,10-48.20 6.29 79 6.29 8108 26,80-58.00 07+07+07+12+12 7.007.00 7.00 12.00 12.00 45.00 8.30-48.20 8 7.08 7.08 12.13 12,13 45.50 6.70-57.10 07+07+07+12+15 85 5 11,75 14.697 7,07 7. 7 7.07 12,13 1 .16 48,50 680-58-00 07+07+07+12+18 .45 6.45 6.4547.00 8.2 0-48,20 6.66 6.66 6.66 11. 1 17.12 48.50 6.80-58.00 07+07+07+12+24 .77 5.77 5.77 9.89 19.79 47. 0 8.10-48.20 20.42 6.80-58.00 07+07+07+15+15 6.45 6.45 6.4513.82 13.82 47.00 7,90-48.20 6.66 6 4 14,26 6.80-59,00 07+07+07+15+186.09 09 13,06 15.67 47,00 7.90-48,20 6.29 6.29 6.29 13.47 16.17 48.5 6.80-58-00 07+07+07+18+18 5.77 5.77 5.77 14.84 14. 4 47.00 7.90-48.20 17 15,32 49,50 6,80-58.00 07+07+09+09+09 00 00 00 00 00 4 1,00 8,30-44.80 .10 7.10 9.13 9.136,70-56,00 07+07+09+09+12 7.00 7.00 9.00 9.00 12.00 44.00 8.30-47.30 7,08 7 9.10 12.14 446.70-56,80 07+07+09+09+157.00 00 00 47.00 8.20-48.20 7,07 7.07 9.10 9.10 15.16 47. 7 07+07+09+09+186.58 46 8.46 16,92 47.002 0-48.20 6,79 6.79 8,73 .7 0 0 07+07+09+09+24 5.88 5.88 7.55 7.55 20.14 47.00 8.10-48.20 07+07+09+12+12 .0 1 1 47,00 2 7 7,07 9.10 12.13 1 6.70-57.70 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 8 of 12 5MXS48TVJU Capacity Tables Cooling Capacity of each indoor unit Combination of!ndoor Each Capacity Total Indoor Unit Capacity unit A room B room C room D room E room Rating (min-max) 07+07+09+12+15 6.58 6,58 8.46 11.28 14.10 47.00 8.20-48.20 6.79 6.79 8.73 11.64 14.55 48.50 6.80-58.00 07+07+09+12+18 6.21 6121 7.98 10,64 1 8,20-48.20 48.50 6,80-58,00 07+07+09+15+15 6.21 6.2113. 0 47.00 7,90-48,20 6.41 6,41 8.24 13,73 13,73 07+07+09+15+18 5.88 5.88 7.55 12. 9 15.11 47. 0 7.90-48.20 6.06 6.06 7.79 12.99 15. 9 48.50 6.80-S8.00 07+07+12+12+12 6,586.58 11.28 11.28 11.2.9 47,00 8.30-48.2 6.79 79 11,64 11.64 11.64 07+07+12+12+15 6.21 6.21 10.64 10.64 13.30 47.00 -4 .41 6.41 10.98 10. 8 13.73 48.50 6.80-58.00 07+07+12+12+18 5.88 5.8810.07 10.07 15.11 47.00 8.20-48.20 6,06 6.06 10.39 10.39 15,59 48.50 6.80-58,00 07+07+12+15+15 5.88 .8 10,07 12.59 12-597• 7.90-48,20 6.06 6.06 10.39 12.99 12.9948.50 6.80-58.00 07+09+09+09+09 TOD9.00 9.00 9.00 9.00 43.00 8.30-46.50 7.08 9.10 9.10 9.10 9.10 43.50 6.70-56.50 07+09+09+09+127.00 12. 8.30-48.20 7.08 9.10 9,10 9.10 12.13 46.50 6.70-57,40 07+09+09+09+15 6,718,63 8.63 14,39 47.00 8,20-48.20 6.93 8.91 8,91 8.91 14. 5 48,50 6.80-58.00 07+09+09+09+18 6.33 8.13 8.13 8.13 16.27 47.00 8.20-48.20 6 16.79 48.50 6.80-58.00 07+09+09+09+24 5,677 7.29 7 19.45 47,00 8.10-48.20 7. 20.07 48.50 6.80-58,00 07+09+09+12+126.71 1 1 7• 8.30-48.20 6.93 8.91 8.91 11.88 11.88 48.50 6.70-58.00 07+09+09+12+15 6.33 8.13 8.13 10.85 13.56 47.00 8.20-48.20 6.53 8,39 8.39 11.19 13.99 48,50 6.80-58,00 07+09+09+12+187.69 98 10,25 15.38 47.00 .2 -4 . 6.17 4 48,50 6.80-58.00 07+09+09+15+15 5.98 7.69 7.69 12.82 12. 2 47.00 7.90-48.20 6.17 7.94 7.94 13.23 13.23 48. 0 6.80-58.00 07+09+09+15+18 5.677.29 7.29 12.16 14.597.80-48,20 5.85 7 7.53 12,5448,50 07+09+12+12+126.33 8.13 10.85 10,85 47 6.53 8.39 11.19 11.10.85 11.19 48.50 6.70-58.00 07+09+12+12+15 5.98 7.69 10.25 10.25 12.82 47.00 8.10-48.20 7 7 1348.50 6.80-58,00 07+09+12+12+18 5.67 7.29 9.72 9,72 14.5 47.00 8.10^4&20 5.85 7,53 10,03 10.03 15,05 48,50 6.80-58,00 07+09+12+15+15 5.67 7.29 9.72 12.16 12.16 47.0 .80-48.20 S.85 7.53 10.03 12.54 12.54 48.50 6.80"58.00 07+12+12+12+12 5.9810,25 10.25 10.25 7 10,58 10.58 10,58 10.58 48.50 6.70-58.00 07+12+12+12+15 S.67 9.72 9.72 9.72 12 7• 8.10-48.20 5.85 10.03 1 4 48.SO 6.80-58,00 09+09+09+09+09 9 00 9.00 9.00 9.00 45.00 8.30-48.2 9.10 9.10 9.10 9.10 9.10 45.50 6,70-57.10 09+09+09+09+12 8.81 8.81 8.81 8,81 11,75 48,30-48.20 9109 9.0 9.09 9109 2. 09+09+09+09+158.29 2 47.00 8,20-48.20 8.56 8.96 8.56 8.56 14.26 48.50 6.80-58.00 09+09+09+09+18 7.83 7.83 7.83 7.83 15. 7 47.00 8.20-48,20 8.08 8.08 8.08 8108 16.17 48.50 6,80-58.00 09+09+09+12+12 8,29 8.291 8,30-48.20 1.41 11,41 48.50 6,70-59.00 09+09+09+12+15 7 7.83 7.83 10.44 13.06 47.00 8.10-48.20 8.08 8.08 8.08 10.78 13.47 48.50 6.80-58.00 09+09+09+12+18 7 42 4 7,00 8.10-48. 1 1 09+09+09+15+15 7,42 7,42 7,42 12.37 12.37 47.00 7.80-48.20 7.66 7,66 7.66 12,765 09+09+12+12+12 7.83 7.83 10.44 10.44 10.44 47. 0 8.30-48.20 8.08 8.08 10.78 10.78 10.78 48. 0 6.70-58.00 09+09+12+12+15 7.42 7.42 �21 1 12. 4 -58.00 09+12+12+12+127 r-2.66 10.21 1 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 9 of 12 5MXS48TVJU Capacity Tables Ducted, 60 Hz, 200-230V Cool ingCapacity of each indoor unit Combination of indoor Each Capacity Total Indoor Unit Capacity unit A room B room C room D room E room Rating (min-max) 09 9.00 - - 9,00 3,30-11.00 11.53.40-17,30 12 12. 0 - - - - 12.00 4.20-14.00 1 3,50-23.10 15 15.00 - - - - 15.00 4.80-17.50 19. 0 3.60-28,80 18 1 - - - - 4.80-21,00 2424.00 - 24.00 6.00^'2 .7 27. 0 4,80-39.90 09+09 9.00 9.00 - - - 18.00 4.90-21.00 1 1 09+12 9,0012.0021,00 5.00-23.80 10.80 14.4025.20 3,60-37,30 09+15 9.00 15,00 - - - 24.00 7.70-26,70 09+189.00 27.00 7.80-29,50 9183 7 29.50 6.50-4 09+24 9.00 24.0033.00 35,20 .2 24.65 - - - -47 ,90 12+12 12,00 12.00 24,00 13.70 13.70 27.40 4.80-39.90 12+15 12.00 15.00 - - - 27.00 7,80-29.50 13.11 1 - 29-50 6.50-42. 12+18 12.001 - - - 30.00 7.80-32.40 12.69 19.02 31,707_ 12+24 12,004. - - 36,00 8 12.20 24.40 36.60 6.50-50.50 15+15 15. 0 15.00 - 30.00 8.10-32.40 15.85 1 .70 6.50-45,2 15+18 15.00 1 - - - 33.00 8.10-35.20 15,41 18.49 - 33,90 6.60-47.90 15+24 15.00 74.00 - - - 8,20-41.70 15.04 24.06 39.10 6.60-51.70 18+18 18.00 19.00 00 8' 10-38.4018.30 18,30 36.60 6,60-50.50 18+24 1 - - - 42.0 9.20-44.90 17.83 23,77 41. 24+24 23.00 23.00 - - - 46,00 8.30-46,00 09+09+09 9.00 9.00 - - 27.00 7,90-29,50 6.50-42,60 09+09+12 9.00 9.001 - - 30,00 7.90 1 9,51 12.68 09+09+15 7 5 9.2533.90 6.60-47,90 09+09+18 9.00 9.001 8.00 36,00 8.20-38,40 09+09+24 9.00 9.004 - 42.00 8,20-44.90 1 8.91 23.77 4 6.60-52.80 09+12+12 9.00 9.25 12,33 12.33 33.906,50-47.90 09+12+15 9.0012.00 15,00 36.00 .4 9.15 12.20 15,25 36.60 6.60-50.50 09+12+18 9.00 12.00 18.0 - - 0 8.20-41.70 9.02 12,03 1 6,60-51,70 09+12+24 9.00iz.00 24 - - 45.00 8.20-46.00 8.80 11.73 23.47 44.00 6,60-54,00 09+15+15 9.00 15.0015.00 39.00 8.30-41.70 9.02 15.04 15.04 39.10 6.60-51.70 09+15+18 00 00 00 _ _ 42.00 -44' 90 8.91 14.8 6.60-52.80 09+15+24 8.634 38 00 00 8,30-46.00 4.5 2 6,70-54.00 09+18+18 1 - - 45.00 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 10 of 12 5MXS48TVJ U Capacity Tables 6A, Cooling Capacity of each indoor unit Combination of indoor Each Capacity Total Indoor Unit Capacity unit tA m B room C room D room E room Rating (min'max) 09+18+24 16.24 21,65 ---------- - 8.30-46,00 8.21 16.41 21.88 - - 46.50 6.70-54.00 09+24+24 7.26 19. 7 19.37 - - 46.00 8,30-46.00 4 19.58 19.58 - - 46.50 6,70-54,00 12+12+12 12.00 12.002 - - 36,00 7,90-38.40 12.20 12.20 12.20 - 36.60 6,50-50.50 12+12+15 12.00 12.00 15.00 39.00 8.20-41.7 12.03 12,03 15.04 - 39.10 6,60-51.7 12+12+1812.00 00 - - 42,00 8,20-44,90 11-89 11,89 7. - 41,60 6.60-52.80 12+12+24 11,50 11.5023.00 - - 4 8.30-46,00 11-63 11. 3 23.25 46.50 6.60-54.00 12+15+15 12.00 1S.00 15. - - 42.00 8.30-44.90 11.99 1 - - 41.60 6.60-52.80 12+15+18 00 00 - - 4 9.30-46.00 11,73 14.677. - - 6,70-54,00 12+15+24 10.82 13.53 21. - - 46.00 8.30-46.00 10.94 13.68 21.8 - - 46.50 6.70-54.00 12+18+18 11-50 17.25 27.25 - - 46.00 8.30-46.00 3 17,44 17,44 4 0 12+18+24 22 15.33 20.44 - - 46.00 8.30-46.00 10.33 15,50 20,67 46.50 6.70-54,00 15+15+15 15.00 15.00 15.00 - - 45.00 8.30-46.00 14.67 14.67 14.67 - - 44. 0 6.70-54.00 15+15+18 1 .38 14,38 17.25 - - 4 8,30-46.00 14.53 14.53 17,44 46.50 6,70-S4,00 15+15+24 1 .44 - 46,00 8,30-46.00 - 12. 2 12. 2 20.67 - - 46.50 6.70-54.00 15+18+18 13.53 16.24 16.24 - - 46.00 8.30-46.00 13.68 16-41 - - 46.50 6.70-54.00 15+18+24 7 46.00 8.30-46,00 22 - - 46.50 6.70-54,00 18+18+18 33 33 1 - - 4 15.50 15.50 15.50 - - 46.50 6.70-S4.00 09+09+09+099100 - 36.00 8.20-38.40 9.15 9.19 9,15 9115 09+09+09+129.00 9.00 9.00 12. - 41.7 9.02 9.02 9.02 12.03 39.10 6.60-51.70 09+09+09+15 9.00 9.00 9.00 15-00 - 42.00 8.30-44.90 8.91 1 8191 14 - 41.60 6.70-52.80 09+09+09+18 � 0 9.00 9,00 18.00 - 45.00 8.80 9.80 R.Rn 17.60 - 44,00 6.70-54.00 09+09+09+24 8.12 8.12 8.12 21.65 - 46.00 8.30-46.00 8.21 8.21 8,21 21.88 46.50 6.70-54.00 09+09+12+12 9100 9.00 12.00 12. 0 - 42.00 8.20-44.90 8.91 8191 11.89 it,89 41.60 6,60-52.80 09+09+12+15 9.00 9.0 - 45,00 8,30-46.00 8,80 8180 11,73 14,67 44.00 6,70-54,00 09+09+12+18 8.63 3 11.50 17.2 - 46 8.3 -46.00 8.72 8.72 11.63 17.44 - 46.50 6.70-54.00 09+09+12+24 7.67 7.67 10.22 20.44 - 46.00 8.30-46,00 7,75 7.7520.67 46.50 7 ^ 4 .00 09+09+15+15 63 - 48,30-46,00 8.72 8.72 14.53 14. - 46.50 6.70-54.00 09+09+15+18 8.12 8.12 13,53 16. 4 - 46.00 8.30-46.00 8.21 R21 13.68 16.41 - 6.70-54.00 09+09+15+24 7,26 - 46.00 7.34 7.34 1 - 46.50 6.70-54.00 09+09+18+18 67 - 46.00 7.75 7,75 15.50 1 .50 - 46.50 6.70^ 54.00 09+12+12+12 9.00 12.00 12.00 12.00 - 45,00 8.20-46,00 8.80 1133 11,7311,73 - 44,00 6.60-54,00 09+12+12+1511.50 63 4• - 46,00 8.30-46.00 72 11.63 11.63 14.53 4 09+12+12+18 8.12 10.82 10. 2 16.24 - 46.00 8.30-46. 8.21 10.94 10.94 16.41 - 46.50 6.70-54.00 09+12+12+24 26 - 46.00 6 7.34 9,79 9,79 - 46.50 6.70-54.00 09+12+15+1513.53 13.53 - 48.30-46.00 1 4 3. - 46.50 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 11 of 12 5MXS45TVJU Capacity Tables Cooling Capacity of each indoor unit Combination of!ncloor Each Capacity Total Indoor Unit Capacity unit A room B room C room D room E room Rating (min-max) 09+12+15+18 7.67 10.22 12.78 15.33 - 0 7.75 10.33 12. 2 46,50 6,70-54,00 09+12+18+18 26 68 53 a - 46.00 8,30-46.00 7,34 9.79 14.68 14,684 6,80-54.00 09+15+15+15 67 1279 78 _ 7 2. 146.5O 70-54.00 09+15+15+18 7.26 12.11 12.11 14. 3 - 46.00 8.20-46.00 7,34 2. 4 12.24 14.68 4 6,80-54,00 12+12+12+121150 11.50 11,50 - 46,00 8,20-46.00 11.63 11.6311.63 46.50 6,60-54,00 12+12+12+15 10.82 10. 2 10.82 13,53 - 46.00 8,30-4 .00 10.94 10.94 10.94 13.68 46.50 6.70-54,00 12+12+12+1810,22 2 15.33 - 46.00 8,30-46,00 10-33 10.33 10.33 1150 46.50 6,70-54.00 12+12+15+1510-22 22 12.78 1 2.78 46,00 8.30-46.00 10.33 10.33 12.9212 12+12+15+18 9,68 9.68 12.11 4 0-46.00 12+15+15+15 9.68 12.1112.11 12.11 46.00 2 -4 9.79 12.24 12,24 12.24 46.SO 6,70-54,00 09+09+09+09+09 00 00 00 00 00 a 5.00 8,30-46.00 8.80 8.80 8.80 8.80 8.80 44.00 6.70-54,00 09+09+09+09+12 8,63 8.638 1 4 6,00 8.30-46.00 8.72 8.72 8.72 8,72 1146.50 6.70-54.00 09+09+09+09+15 .12 8.122 1 8,12 13,53 46. 0 830^'4 6.00 9.21 8.21 8.21 8 09+09+09+09+18 7.67 7.67 7.67 7.67 1 S.31 46.00 8.30-46.0 7.75 7,75 7.757.75 15 4 -54.00 09+09+09+12+12 8.12 8.12 8112 10.82 1 -4 6.00 8121 8.21 8,21 4 10.94 46.50 6,70-54.00 09+09+09+12+15 7.67 7.67 7.67 10.22 12.78 4 "4 6.00 7,75 7,75 7.75 10,33 12,92 46.50 6.70-54,00 09+09+09+12+18 7.26 2 7.26 9.68 14.S3 46.00 8.30-46.00 7,34 7. .09+09+09+15+15 09+09+12+12+12 7.67 7.67 10.22 10.22 10.22 46.00 8.30-46.00 7.75 7.75 10,33 10.33 10,33 46.50 6.70-54.00 09+09+12+12+15 7 2 4 6.00 7 4 4 12.24 6,70-54.00 09+12+12+12+12 7.26 . 4 939 9.797 6,70-54.00 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:May 2019 Page 12 of 12 Job Name: Tag# f Submittal Data Sheet FTXS18LVJU 1.5-Ton Wall Mounted Indoor Unit Indoor Specifications Cooling Heating H M H M Airflow Rate(cfm) 583 484 625 526 L SL L SL 385 360 431 399 Sound(dBA) f _ rr'r H/M/L/SL 46/41/33/33 45/40/35/32 Dimensions(H x W x D)(in) 13-3/8 x 41-5/16 x 9-3/4 `- Weight(Lbs) 31 Nominal Capacity(Btu/hr) 18,000 Complete warranty details available from your local dealer or at *See Outdoor Unit for Rated Capacities www.daikincomfort.com.To receive the 12-Year Parts Limited Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California or Quebec.If product is installed in a commercial application,limited warranty period is 5 years. Piping Liquid(in) 1/4 Electrical *208/230v Gas(in) 1/2 Cooling Heating Drain(in) 5/8 Running Current(Rated)(A) .32/.30* .32/.30* Power Consumption (Rated)(W) 38/38* 38/38* [Optional Accessories Included Part Number Description BRP072A43 Wireless Interface Adapter(S21 Adapter Included) BRC944132-A08 Wired Remote Controller Kit(Includes BRC944132&BRCW901A08) BRCW901A03 Wired Remote Controller Cable-10 ft(For BRC944132) BRCW901A08 Wired Remote Controller Cable-25 ft(For BRC944132) KRP928BB2S Interface adaptor for DIII-NET DACA-CPI-1 Inline Condensate Pum (Fits inside all Daikin wall&floor mount units) DACA-CP4-1 External Condensate Pam KAF970A46 Air-purifying filter with hotocatalytic deodorizing function(without frame) Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:September 2018 Page 1 of 2 N L 7 O O ai L N bD 3 M a r J }o THE MARK(�)SHOWS PIPING DIRECTION E�>AIRFLOW(INDOOR) L LEFT REAR 41-5/16(1050mm) RIGHT E W o INCLUDING / m Q¢ m INSTALLATION PLATE) `a O; E 9-13/16(250mm)_ LL w p t 9-3/4(248mm) z ¢Q o, a w. c m MIN.1-15/16(50min) �, MIN.1-15/16(50mm) o -- — — -- (SPACE FOR (SPACE FOR L -, FRONT' NAMEPLATE MAINTENANCE) REQUIRED SPACE MAINTENANCE) c RILLS E x aia FIXING Z; TERMINAL BLOCK- ~ SCREWS co WITH c (INSIDE) GROUND TERMINAL ° v 0 (INSIDE) _ u o BOTTOM+ INTELLIGENT EYE SENSORC) m O 0° FLAPS' OPERATION LAMP =SIGNAL RECEIVER ° 7 o�• 7 T • LAMP N C INTELLIGENT G NT EYE LAMP GAS PIPE 4,112(012.7mm)CuT DRAIN HOSE o Em (THE LENGTH OF PIPE OUTSIDE (CONNECTING PART -- - - THE UNIT:ABOUT 15-3/4(400mm)) 6mm ° INDOOR UNIT ON/OFF O.D.O -- - -- --- -- -- -- -- SWITCH THE HOSE LENGTH OF OUTSIDE N t LIQUID PIPE 01/4(�6.4mm)Cu on _ - —— ROOM TEMP.THERMISTOR. (THE LENGTH OF PIPE OUTSIDE THE UNIT:ABOUT 18-5/16(465mm)) SIGNAL (INSIDE) THE UNIT:ABOUT 18-1/8(460mm)). - L° s MODEL NAME PLATE E . (� TRANSMITTER E J 3 ® 2-5/16(58 11/16(18mm) UP/DOWN BLADE ANGLES 41-5/16 1050mm u _ 37-5/16(947mm) 1-3/8(35.5mm) ICU 6 v v (AUTOMATIC) — ----- ----- E c o Y Fp COOLING,DRY HEATING. FAN E]2E oEE N zE ° vcEE^w 15`co V25' e o 15° I Cb m > :a � m ° 30` 40° 25` 75° +_ ° 50` 60' + E 70° 75` 70° WALL HOLE FOR EMBEDDED WALL HOLEE RIGHTILEFT(AUTOMATIC) PIPING�3-1/e(¢80mm)HOLE @3 1/8(�BOmm)HOLE iE E 11 2-9/16 65mm) 3-1/2 89mm s}LLI , v C D WIRELESS REMOTE CONTROLLER STANDARD LOCATIONS OF WALL HOLES ° (ARC452A21) C:3D074024A a Ln J � v co v o r o U > CI J D > O v Q C VI f0 C Y L Y 0n 0 7 Job Name: ' Tag# Submittal ®ata 'Sheet FTXS12LVJU 1-Ton Wall Mounted Indoor Unit Indoor Specifications - - ,,_. - ---- ------ - --- - - _.-_: - --- -----__ .. . .._: Cooling Heating - —-- - -- = -- =- _-- - - H M H M Airflow Rate(Cfm) 403 307 438 335 L SL L SL « 205 155 240 212 Sound dBA ( ) 45/37/29/23 45/39/29/26 H/M/L/SL V)#-\',')DA,NFP' Dimensions(H x W x D) (in) 11-5/8 x 31-1/2 x 8-7/16 –`—` Weight(Lbs) 22 Complete warranty details available from your local dealer or at Nominal Capacity(Btu/hr) 12,000 www.daikincomfort.com.To receive the 12-Year Parts Limited *See Outdoor Unit for Rated Capacities Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California or Quebec.If product is installed in a commercial application,limited warranty period is 5 years. Piping Electrical *208/230v Liquid(in) 1/4 Cooling Heating Gas(in) 3/8 Running Current(Rated)(A) .13/.12* .14/.13* Drain(in) 5/8 Power Consumption (Rated) (W) 26/26* 28/28* Optional Accessories y AO,04 AF ARL Part Number Description BRP072A43 Wireless Interface Adapter(S21 Adapter Included) BRC944B2-A08 Wired Remote Controller Kit(Includes BRC944B2&BRCW901A08) BRCW901 A03 Wired Remote Controller Cable- 10 ft(For BRC944B2) BRCW90IA08 Wired Remote Controller Cable-2511 or BRC944B2) KRP928BB2S Interface adaptor for DIII-NET DACA-CPI-1 Inline Condensate Pum (Fits inside all Daikin wall&floor mount units) DACA-CP4-1 External Condensate Pum KAF9251342 Air-purifying filter with photocatalytic deodorizing function(without frame) Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:September 2018 Page 1 of 2 O O Y N 3 m cu � Y L THE MARK SHOWS PIPING DIRECTION AIRFLOW(INDOOR)- 31-1/2 INDOOR)% c REAR - U E 0 INCLUDING E ¢ S LEFT RIGHT E O MOUNTING PLATE, o LLcc nw0 6.9116(217mm) V u- a c¢ Lu 2 1-1516(50mm)MIN NIDLn &7116(215mm) 1-15/16(50mm)MI (SPACE/ FOR MAINTENANCE) REQUIRED SPACE (SPACE FOR MAINTENANCE) X o FRONTGRILLE E NAMEPLATE o FIXEDSCREWSE Vd (INSIDE) TERMINAL BLOCK o v c WITH GROUND =o t •2 TERMINAL No o m a v a o BOTTOM 1 INTELLIGENT EYE SENSOR EIN c FLAPS SIGNAL RECOa E m OPERATION LAMP GAS PIPE 0/8(0.5mm)CuT DRAIN HOSE °' O TIMER LAMP (THE LENGTH OF PIPE OUTSIDE (CONNECTING PART c INTELLIGENT EYE LAMP LIQUID PIPE 6114 6.4mm THE UNIT:ABOUT 13-3/4(350mm)) N m c O.D.05/8(b16mm) IN )CuT THE HOSE LENGTH OF OUTSIDE y o c DOOR UNIT ON/OFF SWITCH (Q E (THE LENGTH OF PIPE OUTSIDE. THE UNIT IS APPROX.18-5116(465mm)) ,n (u _ __ - —__ - ROOM TEMP.THERMISTOR'(INSIDE) � THE UNIT:ABOUT I5-3A(400mm))31-112(800mm) J '3 MODEL NAME PLATE r 23-1116(586rnm) ® SIGNALTRANSMITTER 5-3/4145.5mm v m2-5/is(58mm), 11/16(16mm) UP/DOWN BLADE ANGLES -------------------- ----' a Y o (AUTOMATIC) -- L c ® COOLING,DRY HEATING FAN E I I E E " E I I E E Z c •� o 0 5° t I 13 N E E ppp a� Li 15° /fl I IC? m 0 VJ a 30' ' `c ' �U cn I. I c� Q M 35° 30°'./ 301- 1 I r E � �° 65 + + - 70° 55° 65° 80° L- ------------------- -- -) o ® ^ WALL HOLE FOR WALL HOLE 0 2-3/e(6�mm) EMBEDDED PIPING 42.9116(¢65mm)HOLE oN RIGHT EFT 2-5/16(59.5mm) o `m (AUTOMATIC} X2416(065mm)HOLE o a STANDARD LOCATIONS OF WALL HOLES E a WIRELESS REMOTE CONTROLLER t' a /J (ARC452A21) 4S °5 C:3D074094A j c v m c u0 U) > �✓x o . o v CL m C _ Y E LL 6 fl O 7 N Job Name: Tag# 17 .DAIKIN Submittal Data Sheet FTXS09LVJU .75-Ton Wall Mounted Indoor Unit Indoor Specifications Cooling Heating -- - - - - H M H M Airflow Rate(cfm) 381 279 420 321 L SL L SL 194 145 233 219 Sound(L H/M/L/SL T41/33/25/22 42/35/28/25 Dimensions(H x W x D)(in) 11-5/8 x 31-1/2 x 8-7/16 Weight(Lbs) 20 Nominal Capacity(Btu/hr) 9,000 Complete warranty details available from your local dealer or at *See Outdoor unit for Rated Capacities www.daikincomfort.com.To receive the 12-Year Parts Limited Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California or Quebec.If product is installed in a commercial application,limited warranty period is 5 years. Piping Liquid(in) 1/4 *208/230v Gas(in) 3/8 Electrical Drain(in) 5/8 Cooling Heating Running Current(Rated)(A) 09/.08* 11/.10* Power Consumption(Rated) (W) 18/18* 21/21* Optional Accessories Included Part Number Description BRP072A43 Wireless Interface Adapter(S21 Adapter Included) BRC944B2-A08 Wired Remote Controller Kit(Includes BRC944B2&BRCW901A08) BRCW90IA03 Wired Remote Controller Cable- 10 ft(For BRC944B2) BRCW90IA08 Wired Remote Controller Cable-25 ft For BRC944B2) ICRP928BB2S Interface adaptor for DIII-NGT DACA-CPI-1 Inline Condensate Pum (Fits inside all Daikin wall&floor mount units) DACA-CP4-1 External Condensate Pum KAF925B42 kir-purirying filter with photocatalytic deodorizing function without frame) Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:September 2018 Page 1 of 2 Lz) j N f O O a L N Y m THE MARK SHOWS PIPING DIRECTION AIRFLOW(INDOOR) j 31-1/2(800mm) �`���✓✓✓✓✓ / c o CI R VZ,,, , EAR.. V E LEFT - RIGHT INCLUDING 1 E O g MOUNTING PLATE) o 5 ULL O c 8.9!16(217mm) ¢Cc' Lu 1-15/16(50mrr1)MIN to Q°- o 6-7116(215mm) LLL° (SPACE FOR v 1-15/16(50mm)MIN o m MAINTENANCE) REQUIRED SPACE (SPACE FOR MAINTENANCE) ,^. 'a v FRONTGRILLE-E NAME PLATE N FIXED SCREWS (INSIDE) TERMINAL TERMINAL BLOCK u, WITH GROUND, 0 -0 c TERMINAL o= = o o o, ,n o on N a_0 0 BOTTOM INTELLIGENT EYE SENSORN T FLAPS SIGNAL RECEIVER o a OPERATION LAMP GAS PIPE WS(o.5mm)CUT -L-DRAIN HOSE E °c° (THE LENGTH OF PIPE OUTSIDEv o (CONNECTING PART LL TIMER LAMP THE UNIT:ABOUT 13-3,'4(350mm)) c +� O.D.�5/e(o16mm) INTELLIGENT EYE-LAMP ° L LIQUID PIPE 61l4(06.4mm)CuT THE HOSE LENGTH OF OUTSIDE "' °D - cu INDOOR UNIT ON%OFF SWITCH HE LENGTH OF PIPE OUTSIDE i'n a -- - - E THE UNIT:ABOUT 15.314(400mm)) THE UNIT IS APPROX.18-5/16(465mm)) Y Y ---- ROOM (INSIDE) ,n 31-1/2(800inm) Ln co U y MODEL NAME PLATE 0-1/16(588mm) . Z v ® —SIGNAL TRANSMITTER m 5-3/4 145.5mm v 2-5116(58mm) 11/16(18mm). UP/DOWN BLADE ANGLES (AUTOMATIC) - - --- ------- ----� ¢ c COOLING,DRY HEATING FAN E i I E E II 0 Y E I I E E z c •� ° ° ° ° 5° Lo ° ° 1 I E ryCn� 00000 15° �30' I I T 2 W s:e 35° 30°° 30� I I E M 45° 55° "��° 65° 65° + ------------ -- - ® o WALL HOLE FOR WALL HOLE oto 2-3/8(60mm y52.9116(665mm)HOLE c o RIGHT%LEFT ) EMBEDDED PIPING ( ) N 2-5/16 59.Smm L-H (AUTOMATIC) �2-9/16(�65mm)HOLE o �7 WIRELESS REMOTE CONTROLLER STANDARD LOCATIONS OF WALL HOLES' o E C:3DO74094A v a (ARC452A21) ,;( v m yam � 0 0 _0 >J� 2 o v a � G 4 Y E LL � 7 �. N � mith. Residential Electric Water Heater V®LTEX° HYBRID ELECTRIC HEAT PUMP WATER HEATER X015 The Voltex Hybrid Electric heat pump water heater from A. 0.Smith is the most cost effective energy-efficient option available for consumers who want to save money on their utility bills.Voltex can reduce water heating costs up to 71% and provide payback in 2-3 years.With annual savings of$437 or more,there is no better way to go green than Voltex, HOW DO THEY WORK? Absorb ambient heat from the surrounding air to heat water using a compressor and "Environmentally-Friendly" R134a refrigerant • Self-contained heat pump unit is integrated into the top of the tank • Multiple operating modes to maximize efficiency and performance Smith. QUALIFIES FOR MANY STATE AND LOCAL UTILITY REBATES- CHECK WWW.DSIREUSA.ORG INCREASED ENERGY EFFICIENCY DRY FIRE PROTECTION • Improved efficiency designed in,to • Control system checks to ensure the ensure available hot water at the lowest tank is full of water during start up to r possible cost.Up to a 3.24 Energy Factor prevent dry firing the heating elements (EF)Rating conserves energy and meets ELECTRONIC USER INTERFACE ENERGY STAR qualifications • User-friendly electronic interface allows :' CHOICE OF OPERATING MODES ; =: ,. easy control of temperature setting, • Select from Efficiency,Hybrid,or Electric operating mode,and communicates modes to match heating requirements to diagnostics r environmental conditions. • Easy to read temperature display(see • Hybrid mode automatically adjusts back)shows temperature in OF or°C }" between compressor and element, • Advanced diagnostics convey error depending upon heat requirements. messages for service purposes.The last • Vacation mode reduces operating costs four error messages are saved in the and provides freeze protection during control system memory. extended absence OTHER FEATURES BACKUP ELECTRIC ELEMENTS • Ideal for basements or garage • Long-lasting backup heating elements installations;the compressor transfers Gw1 help heat water according to heat to the water while dehumidifying environmental conditions,demand,and and cooling the ambient air the chosen operating mode • Washable air filter is easily removed for COREGARDTm ANODE ROD routine cleaning • Our anode rods have a stainless steel TEN YEAR LIMITED WARRANTY ca© c UL us core that extends the life of the anode . For complete informationconsult LISTED , rod allowing superior tank protection far longer than standard anode rods written warranty or go to hotwater.com • 66 and 80 gallon models have dual • 1 U anodes for added protection. 02015 A.0.Smith corporation.All Rights Reserved Page 1 of 2 www.hotwater.com 1800-527-1953 Toll-Free USA I A.0.Smith Corporation 1 500 Tennessee Waltz Parkway I Ashland City,TN 37015 AOSXE50004 ® t h Residential Electric m I Water Heater Model Gallon Energy Factor by Mode 1st Hour Rating(Gal)By Mode Dimensions in Inches Approx. Number Capacity Shipping Warranty Term Efficiency Hybrid Electric Efficiency Hybrid Electric A B C D E Weight(Ibs) HPTU-50 50 3.61 3.24 0.93 44.4 70 57.3 63 22 40-518 3-3(4 40-1/2 196 10 HPTU-66 66 3.44 3.17 0.92 62.5 80 78.6 61 27 38 4 38 289 10 HPTU-80 80 3.27 3.06 0.92 76.3 95 90.1 69 27 46 4 46 307 10 Requires 30 amp breaker. Top T&P option not available. 'I IW4 WWI I ' • EFFICIENCY �® HYBRID ` • EtECIRIC INKS PoKN SJ'Nf � YACATKkI Ergye rpuars L ELECTRONIC USER INTERFACE • User friendly,easy to read display. A • LEDs clearly indicate the current operating mode. • Easily select operating mode: B • Efficiency • Hybrid E • Electric • Vacation • Display communicates current status,mode and set point,and displays error messages when applicable. 0 • Vacation mode programmable up to 99 days. g EFFICIENCY MODE ° • Utilizes the heat pump for all water heating. • Automatically reverts to heating element if ambient air or water OTHER FEATURES: temperatures are outside optimal operating range for heat pump. HYBRID MODE • Sacrificial anode to protect against tank corrosion. • Utilizes the heat pump or heating element,depending on demand. • Environmentally-friendly non-CFC foam insulation. • Durable,enhanced-flow brass drain valve. ELECTRIC MODE • CSA certified and ASME rated temperature&pressure relief valve. • Standard electric water heater operation. OPERATING REQUIREMENTS: VACATION MODE • Requires provision for condensate draining;if a suitable drain is • One touch operation maintains tank temperature of 60°F not available,a condensate pump is required. (15.6°C)during vacation or extended absence to reduce • 208/240 VAC 60Hz single phase 30 amp power supply. operating costs and provide freeze protection. • Programmable up to 99 days. ForTechnical Information, 800-527-1953.A. 0 Smith:Corporationreserves the rightto make product chane• or e evements without prior e Page 2 of 2 www.hotwater.com 1800-527-1953 Toll-Free USA A05XE50004