Loading...
HomeMy WebLinkAbout49288-Z �do� Fit/, Town of Southold 7/11/2023 a� y� P.O.Box 1179 o _ --W �.# 53095 Main Rd 'y1j�1 dao i;;� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44259 Date: 7/11/2023 THIS CERTIFIES that the building GENERATOR Location of Property: 25500 Route 25, Orient SCTM#: 473889 Sec/Block/Lot: 18.-6-10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/12/2023 pursuant to which Building Permit No. 49288 dated 5/22/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"accessory generator as applied for. I The certificate is issued to Sutton,Alexander&Tracy of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49288 6/15/2023 PLUMBERS CERTIFICATION DATED th riz ignature �soFF TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE o • � SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONESET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49288 Date: 5/22/2023 Permission is hereby granted to: Sutton, Alexander 25500 Route 25 Orient, NY 11957 To: legalize "as built" generator as applied for. • At premises located at: 25500 Route 25, Orient SCTM #473889 Sec/Block/Lot# 18.-6-10 Pursuant to application dated 4/20/2023 and approved by the Building Inspector. To expire on 11/20/2024. Fees: CERTIFICATE OF OCCUPANCY $50.00 ACCESSORY $200.00 ELECTRIC $170.00 Total: $420.00 Building Inspector pF SOUjyo! 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 aQ sean.devlin(Ft-)town.southold.ny.us Southold,NY 11971-0959 Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Alexander Sutton Address: 25500 Route 25 city,Orient st: NY zip: 11957 Building Permit#: 49288 Section: 18 Block: 6 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Surrey X Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency StrobeHeat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 28 kW Generac Generator w/ 200A Transfer Switch Notes: Generator Inspector Signature: - Date: June 15, 2023 S.Devlin-Cert Electrical Compliance Form OF SOUIyO� � �� �5`�� • l�N'1i�i # * TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: S :3U I lT ' DATE lql INSPECTOR x f + ehA t 8 Y`Y Y a N� b ` + e IN � � n+w r�• ;r�4y��.'�t ty� c1'�1 r�+ v'"vy��t'��4�(��' ''` � , _ ESSUR �UEL. INLET QQ35X153 . '6 i NUMBER V ; jAPOF, E: 10 Tn W.C. �--p RE55UK S4itJ, ,t#LET p 12 In W.CO INL�C PRESSU20 kw 35000�BTU/HR • MAX T:20 _ t1AX FLOW RATE A .._ ,�. .g _ ,! • ' 'k NATURAL GAS In W.,C. PRESSURE: 3.5 : Crt1N, Itdi_E' PRL SSUREkw 30 7 L, W•C80006TU/HR M MAX. Zt1LE` �• s htAX FLOW BATE AT:18, K n • � a . { 4 `., it FIELD INSPECTION REPORT DATE COMMENTS �b FOUNDATION(1ST) y ------------------------------- FOUNDATION (2ND) � z � o V� ppU cn ROUGH FRAMING& y PLUMBING lV � 1 O, INSULATION PER N.Y: y STATE ENERGY CODE y FINAL ADDI IOAL COMMENTS /oV910 iWAHB C . o Z m tN b b O z d r� b H TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 hqps://www.southoldtownny.go Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only tGt �� Zvi PERMIT NO. Building Inspector: D 12 9093 I /1VV / Lo ciL1IW I IVV UtP-J. Applications and forms must be filled out in their entirety. Incomplete TO NOFSnI1TNn1 n applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: 5h 2 2?7 OWNER(S)OF PROPERTY: Name. SCTM# 1000- _ 1� Project Address: Phone#: ✓._I. ."-� -- - (.. _..__._._.. ----_ .Email: ( - -- - - - Mailing Address: t t CONTACT PERSON: Name: ty Mailing Address: -__---- ._-_-_--- Phone Email—� DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION �r ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition S t'�A� Estimated Cost of Project: ❑Other -( ? --��i> ' Will the lot be re-graded? ❑Yes** Will excess fill be removed from premises? ❑Yes L Wo 1 ' a PROPERTY INFORMATION Existing u ofcpropert �'`�-` `'`2 Intended us of roperty: ^1&<%� "`J ----- ---a ---- -- - - -- - --� - -- -- Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yeso IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(pfAt name): ❑Authorized Agent/�nAwner Signature of Applic Date: �Z,C23 CONNIE-D:BUNCH_..._...._._----.w.__.._.__.__...—_..__________._.—_ Notary Public,State of New York STATE OF NEW YORK) No.01BU6185050 SS: Qualified in Suffolk County Commission Expires April 14, 2� COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this �ay of D 20_a$ n''P Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 OoffO(41Ira BUILDING DEPARTMENT.- Electrical Inspector Gym TOWN OF SOUTHOLD o •'` Town Hall Annex - 54375 Main Road -PO Box 1179 -1 • Southold, New York 11971-0959 4,- ao� Telephone (631) 765-1802 - FAX (631) 765-9502 l ' rogerr(cDsoutholdtownny.gov - seand(D-southoldtownny.gou APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: , 2A 2j Company Name: Electrician's Name: License No.: Elec. email:. Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Reqed) Name: Address: ��j�� \�R 57 Cross Street: Phone No.: - 2 Bldg.Permit#: email-.-_- Tax Map District: 1000 Section: Block: Lot: 1,0 CQ,y^ BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 PhF-13 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 R2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 1'J` b I V3 00 jz� t C, r �SufFp��� BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLI) Town Hall Annex - 54375 Main Road -'PO Box 1179 c Southold, New York 11971-0959 a®�Y Telephone (631) 765-1802 - FAX (631) 765-9502 ¢ rogerrCD_southoldtownny.gov - seand@southoldtownny.goy APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: z3 Company Name: Electrician's Name: License No.: Elec. email: ` Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION- (All Information Required) Name: Address: �j _ �v�- OR 57 Cross Street. Phone No.: L2 2 Bldg.Permit#: o email- . I Tax Map District: 1000 - Section: Block: Lot: - BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑ Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 F1 H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION as lb 40 5:314 s .1 ` . CAD FILE DATE: MARCH 2021 SHOWN ARE FROM FIELD OBSERVATIONS AND OR DATA OBTAINED FROM OTHERS. COPIES OF THIS SURVEY MAP NOT BEARING — THE LAND SURVEYOR'S INKED SEAL OR . acres D100�0.: 21\MIAIN ROAD 25500 THE EXISTENCE OF RIGHTS OF WAY EMBOSSED SEAL SHALL NOT BE CONSIDEREE G AND/OR EASEMENTS OF RECORD IF TO BE A VALID TRUE COPY. ANY, NOT SHOWN ARE NOT GUARANTEED. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SUR\ IS PREPARED, AND ON HIS BEHALF TO THE Premises known os: TITLE COMPANY, GOVERNMENTAL AGENCY ANC l25500 Main Road, Orient LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTI— TUTION. GUARANTEES ARE NOT TRANSFERABL l o - n i �p\bo*es ®pt 5� °Spbo N6 � S o\p .off ea9e o 066 \ J o Q\1 P°�sme°� os°Qv°me° ff 1011 fences % b s1oN Zr \q5 o e' "os r o 06 3 s ty all boY 1a5 2 \tig�� oo\s\ps9 �qbt Oyo o \1 po(o �e\\0 beck 1 t ✓ s\eps oocie\e G°over O - - ®` 'CJS' AAPRD ASNOT DATB.P.# FEE: BY: NOTIFY.BUILDING DEPARTMENT- AT . 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: I. FOUNDATION - TWO REQUIRED . FOR POURED CONCRETE ,2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL' -' CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF c,,Oy�Rni n rrnnini sae '� SG NNING BOARD SOUTHOLDiWTRUSTEES jCCUPANCY OR JSE IS UNLAWFUL MTHOUT CERTIFICAT, _. =JF OCCUPANCY ELECTRICAL ON, SPECTION REQUIRED GENERAC uumnumne ocnica7 nesUlenual a uommercial wanauy Venerators OEM_ Air-uooiea uas tngine INCLUDES: Standby Power Rating • True Power" Electrical Technology Model G007077-0(Aluminum- Bisque) -20 kW 60 Hz • Two-Line LCD,Multilingual Digital EvolutionT Controller(English/Spanish/French /Portuguese) • Electronic Governor • System Status &Maintenance Interval LED Indicators • Sound Attenuated Enclosure 1•��I • Flexible Fuel Line Connector +�I • Direct-To-Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation GENERAC' • 5 Year Limited Warranty • Capability to be installed within 18"(457 mm) of a building* QU/Erf c �L us LISTED "Only if located away from doors,windows and fresh air intakes,and unless otherwise directed by local codes rmI unta O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Generac's O SOLIMATE,FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible. Generac's G-Forcer" This state-of-th"d power maximizing regulation system is standard on engine lineup offers added peace of mind and reliability for when you need it the all Generac models.It provides;optimized FAST RESPONSE to changing most The G-Force series engines are purpose built and designed to handle the rig- load conditions and MAXIMUM MOTOR STARTING CAPABILITY by ors of extended run times in high temperatures and extreme operating conditions. electronically torque-matching the surge loads to the engine. Digital voltage regulation at±1%. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer form produce less than 5%Total Harmonic Distortion for utility quality power.This allows network provides parts and service know-how for the entire unit,from the confident operation of sensitive electronic equipment and micro-chip based appliances, engine to the smallest electronic component. such as variable speed HVAC systems. O TESTCRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this SYSTEM TORSIONAL TESTED V MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. "' GENERAC ryp47.3� ��yw"4gfm • • � * Mobile l._ PROMISE ®•� k,Q unk •LWiRm U,e US,vaYp MnlasUc emlf uDn Darts Y' cU Kw - reaiures ana MUMS Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life. • Quiet-Test- Greatly reduces sound output and fuel consumption during bi-weekly exercise. • "Spiny-IW cast iron cylinderwall Is Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High,temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to-*1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Evolution— Controls • Two-line LCD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences. • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,defaults 132 V dropout,175 V pick up. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18"away from a building. Installation System • 1 ft(305 mm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine,prolonging engine life. LU KW Specii�caiions Generator Model G007077-0 Rated Maximum Continuous Power Capacity(LP) 20,00D Watts* Rated Maximum Continuous Power Capacity(NG) 17,D00 Watts* Rated Voltage 208 _ Rated Maximum Continuous Load Current-208 Volts(LP/NG) 69.4/59.0 :Total Harmonic Distortion Less than 5% Main Line Circuit Breaker BD Amp r Phase -- --- -- -t--- --- - --- - - - - - - -- - � - - -- --- - -3 - - - -- - -- - - Number of Rotor Poles 2 Rated AC Frequency _ 60 Hz Power Factor - 0.8 'Battery Requirement(not included)_ _ 12 Volts,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum 456/211 Unit Weight(Ib/kg) Dimensions(LxWxH)iNmm __ _ _ - - - 48x25x29/1218x638x732 Sound output in dB(A)at 23 ft(y m)with-generator operating at normal load** 67 Sound output in d5(A)at 23 ft(7_m)with generator"in Quiet-Test-low speed exercise mode** - - --58 Exercise duration 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Lyiinders 2 Displacement - _ -999 cc `Cylinder Block`— Valve Arrangement - Overhead Valve Ignition System Solid-state w/Magneto Governor System Electronic Compression Ratio __-- -- 9 5:1 Starter -- 12Vdc Oil Capacity Including Filter ---__ _.. ___ _ _. __._ _.-_-__ . _ _. -.- -- - Approx 1.9 gV1.9L Operating rpm 3,6DO Fuel Consumption Natural Gas-ft'/hr(mlft) 1/2 Load 219(6.20) Full Load 307(8.89) ;Liquid Propane-ft3/hr(gaVhr)[l/hr] 1/2 Load 87(2.39)[9.03] Full Load 130(3.56)[13.48] Note:Fuei pipe must be s¢ed far full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7*water column(7-13 mmmercury)for natural gas,10-12'water column(19-22 mm mercury) for LP gas.For Btu content,multiplyft3/hr x2500(LP)orf0/hrx 1000(NG).For Magajoule content,multiply m3/hrx 93.15(LP)or m3/hrx 37.26(NG) Controls Two-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode ButtonsAuto Automatic Start on Utility failure.7 day exerciser. - - -- - -— - __ - - _ _ -- Manual Start with starter control,unit stays on.If utilityfails,transfer to load talxs place. Off Y Stops unit Power is removed.Control and charger still operate. Ready to RuryMaintenance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Returri to Utility Adjustable(Brdwnout Setting) - From 121-148 V/175-187_V Future Set Capable Exerciser/Exereise Set Error blaming Standard Run/Alarmi'Maintenanee Logs - 5D Events Each Engine Start Sequence Cyclic cranldng:16 sec on,7 rest(90 sec maximum duration). Starter Ldek out Starter cannot re-engage until 5 see after engine has stopped. Smart Battery Charger Standard Charger Fault/NlissingAC WarningStandard Lour Battery/Battery Problem Protection and BatteryCondition Indication Standard Automall-c Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/OverlQad/Stepper Overcurrent Protection Standard Safety_Fuse'd/Fuse Problerrr Protection Standard Automatic Lour Oil Pressure/High Oil Temperature Shutdown Standard DvercranWOverspeed(@ 72 Hz)/rpm own Sense Loss ShutdStandard _ . ._____..___.__ ._ ------ ---_. _ ... _ _. High Engine Temperature Shutdavn Standard Internal Fault/Incorrect Wiring Protection Standard Common External Fault Curability Standard Field Upgradable Firmware _ . _._ --- - - Standard "Sound levels ae takenfmm the bontaf tha generator.Sound Ievelstalm from other sides of the genmbrmaybehigherdepending on installation parameters Ratingdefinitions-Standbf.Applicablefor supplying emergency power forthedu ition of the utility peawoutage.Nooverload capability lsardlablefor thisuding.(All rabr)gsinacordmce%vithBS5514,1503046andDllr3271).*Matlmwnkilovoltampsandaurentaresubledtoand limiledbysuch factors asfuel Bturmeg4oule content,a berdtengeaNre,Jtiwde,enginepm%vandmndition,etc Nkinwaipmverdecteasiasabod 3.5 parcentfu each 1,000 feet(304.8 motem)abovesea level,and also will decreassabout 1 percentfur each 6'C(1 O'F)abuve 16 T(60*0. zu KW avallaoie accessories Model# Product Description Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet I G005819-0 126R Wet Cell Battery 1 cell battery for use with all air-cooled standby product(excluding PowerPact®). I 0007101-0 Battery Pad Warmer ;The pad warmer rests under the battery.Recommended for use 9 the temperature regularly falls below 0°F.I (Not necessary for use with AGM-style batteries). r 0007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if the temperature regularly falls below IF. I The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a 10007027-0-Bisque 1 Fascia Base Wrap Kit ;sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting I i holes located in the base. ! !If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from G005703-0-Bisque Paint Kit future corrosion.The paint kit includes the necessary paint to pmperiy maintain or touch-up a generator enclosure. 0006485-0 ;Scheduled Maintenance Kit j Generac!s scheduled maintenance kits provide all the hardware necessary to perform complete routine I maintenance on a Generac automatic standby generator. l G006463-4* I Mobile Link--Cellular ;Generac's Mobile Link allows you to check the status of your generator from anywhere you have access; I i to an Internet connection from a personal computer or with any smart device. ±The Wi-Fi enabled LPfuel level monitor provides constant monitoring of the connected LP fuel tank.Mon- G007005-0* °Wi-FLP Fuel Level Monitor I Itoring the LP tanks fuel level is an important step in making sure your generator is ready to run during an unexpected power f ailure.Status alerts are available through a free application to notifywhen your LP tank' i is in need of a refill. I , "Only applicable for the United States. aimensions a urtPs D nensioasshoemareapprobnwte.Retertoinstallationmaamltoremddimensions.DONOTUSETHESEDIMENSIONSFORINSTALATIONPURPOSES. r"MIN Model UPC 0007077-0 696471002522 ra aT -- O Oil r01'eean� la �erramev�w F t'ZVMW GENERAC" Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189• generac.com 02017 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Pad No.10000003872-D 6/5117