Loading...
HomeMy WebLinkAbout47389-Z OSa fat Town of Southold 6/27/2023 �? P.O.Box 1179 C* _ 53095 Main Rd yfj01 ��o�.;vr Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44221 Date: 6/27/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 420 Beachwood Ln., Southold SCTM#: 473889 Sec/Block/Lot: 70.-10-54 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/11/2022 pursuant to which Building Permit No. 47389 dated 1/26/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar panels to an existing single family dwelling as applied for The certificate is issued to Triolo,Joseph&Dana of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47389 6/26/2023 PLUMBERS CERTIFICATION DATED A thor' a Signatur �o�suFFot,r� TOWN OF SOUTHOLD ay BUILDING DEPARTMENT C* x TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47389 Date: 1/26/2022 Permission is hereby granted to: Triolo, Joseph 6 Woodvale Ln Halesite, NY 11743 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 420 Beachwood Ln., Southold SCTM # 473889 Sec/Block/Lot# 70.40-54 Pursuant to application dated 1/11/2022 and approved by the Building Inspector. To expire on 7/28/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Buil g ector pF 50!/j�Ql 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlina-town.southold.ny.us Southold,NY 11971-0959 QIyCOUM'�A� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Joseph Triolo Address: 420 Beachwood Ln city:Southold st: NY zip: 11971 Building Permit#: 47389 Section: 70 Block: 10 Lot: 54 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED F1 Exit Fixtures Sump Pump Other Equipment: 3.2kW Roof Mounted PV Solar Energy System wl (8) Qcell Qpeak Duo 40OW ModulE AC Disconnect, IQ Combiner Notes: Solar Inspector Signature: Date: June 26, 2023 S. Devlin-Cert Electrical Compliance Form oF saoryO �J # * TOWN OF SOUTHOLD BUILDING DEPT. IOU ,��' 631.765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ �INAL go [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Z"v f DATE -l- ���� INSPECTOR ? # TOWN OF S UTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ol DATE INSPECTOR ,:{:: :air%;^,..•,±;,. ` p T, G0.11'IM�NTS FIELD:ROPECTI N. it ?AT :: ':; .:.: FOUNDATION .IST r: FOUNDATION` CA ROUGH F.. 0 i`- Y�• MULATIQWp 'STATE E1RGY ' til-:• :,}''.'� .�.�.,i:;.���#,�5.,^:4 y��::•�,,,,`.::'; � .. - .. POW D 1 T� 0 Le ,':_":•s:,i is i'r':::�":. HI o�OSUFFOI f coG TOWN OF SOUTHOLD—BUILDING DEPARTMENT in Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtowm.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only F— PERMIT NO. Building Inspector: li JAN 1 1 2n79 I' 1, 1 Applications and forms must be filled out in their entirety. Incomplete BUIL ;IC,o=pT applications will not be accepted. Where the Applicant is not the owner,an iCW' SDU t I OLD Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: SCTM# 1000- �'� )do laaa afya6V -- � h T�.d1U - _ Project Address: Phone#: jllEmail: Mailing Address: / 7/ . _... CONTACT PERSON: Name: Mailing Address: 70 Phone#: 7 Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Other Will the lot be re-graded? ❑Yes O Will excess fill be removed from premises? ❑Yes o 1 Zoho Sign Document ID:DD4JUHZA6ZH71 EAUPT582WBAZBLZTZALl 82U ARAPAK PROPERTY INFORMATION Existing use of property: ,/J Intended use of proper �1 �l �70� p p tY= Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes o IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water Issues as provided by Uiapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and to building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):— 'n IL , Authorized Agent []Owner Signature of Applicant: Date: I) 10 I 2j zz� STATE OF NEW YORK) Ss- COUNTY OF! Do n vc.,I l e— )Et., being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this n �,{. Notary Public DEBRA A SEPULVEDA NOTARY PUBLIC,STATE OF NEW YORK Registration No.olSE6012697 PRO ERTY OWNER AUTHORIZATION i QualifiedinS �tY . e_ re the applicant is not the owner) My Commission Expires h 9;; 1/,:::; residing at _ / ��/jC�L �� Z�0f/1Q. . do hereby authorize U/ to apply on my behalf to the Town of Southold Building Department for approval as described herein.. - Owner's Signature Date Print Owne s Name 2 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o z Town Hall Annex - 54375 Main Road - PO Box 1179 o _ Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerra-southoldtownny.gov - sea nd(D-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: / License No.: ,-d- —!'WZ�- Elec. email: ls' f Elec. Phone No: 49317Z 7 93 I request an email copy of Certificate of Compliance Elec. Address.: 7Z 70 Joe-," JOB-SITE INFORMATION (All Information Required) Name: %l/��� Address: lie IV ' � -� Cross Street: Phone No.: a 7 9 7f�� Bldg.Permit#: �-?a email: n-, i .e,.2-sp<x, r- Tax Map District: 1000 Section: d7,0'Cle Block: -.1,00a BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): -1 syr i 3. ,,o�G/S. Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YESPI"NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 R2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION BUILDING DEPARTMENT- Electrical Inspector �y� TOWN OF SOUTHOLD ; Town Hall Annex- 54375 Main Road - PO Box 1179 "ft 4� Southold, New York 11971-0959 ® 19 Telephone (631) 765-1802 - FAX (631) 765-9502 r_ogerr@southoldtownny.gov - seandCcD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: r f� Company Name: rte ' Electrician's Name: License No.: Elec. email: 17�- -,� J Elec. Phone No: 49317 7 7 " I request an email copy of Certificate of Compliance Elec. Address.: 70 JOB SITE INFORMATION (All Information Required) Name: ,70/ oA Address: Cross Street: Phone No.: ( aj7 7 9 7/1-3 Bldg.Permit#: � email: ir, //3 Tax Map District: 1000 Section: Block: 100a Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 3. / _�/�C�S. Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YESP�f O F-] Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION l+>�� C� BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 gyp" Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr _southoldtownny.gov - sea ndCaD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: (g2=3 11P-5 Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: ri, Address: p 1 Cross Street: Phone No.: Bldg.Permit#: !0-4-7 3 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service[:]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 R H Frame Pole Work done on Service? Y DN Additional Information: PAYMENT DUE WITH APPLICATION 17--or N**N.- NYSI F New York State Insurance Fund 8 CORPORATE CENTER DR,3RD FLR,MELVILLE,NEW YORK 11747-3129 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) 4TA AAAAAA 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 1020 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 706281 07/13/2021 TO 07/13/2022 7/15/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:438572026 U-26.3 A'C�RQ® DATE(MMY ) y CERTIFICATE OF LIABILITY INSURANCE 7/15/7/15/20021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: ROBERTS.FEDE INSURANCE AGENCY PHONE bJ I- - FAX631-365-1766 AIC No Ext): A/C No): 23 GREEN STREET,SUITE 102 E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSURERS AFFORDIATLAN TyNG COVERAGE NAIC# INSURER A: INSURED INSURER B:STATE INSURANCE FUND 523930 Element Energy LLC INSURER C:SHELTER PUINT POINT 81434 ELEMENT ENERGY SYSTEMS INSURER D: 7470 SOUND AVENUE INSURER E: MATTITUCK, NY 11952 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. I�7R TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP POLICY NUMBER MMIDD MM/DD/YYY LIMITS COMMERCIAL GENERAL LIABILITY X X CL00275204 7/14/2021 7/14/2022 EACH OCCURRENCE $ 3,000,000 CLAIMS-MADE 1X­_1OCCUR DAMAGE TO RENTED PREMISES Ea occurrence $ 100,000 A MED EXP(Any one person) $ 5000 IMA389203 7/14/2021 7/14/2022 PERSONAL&ADV INJURY $ 3000000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 3,000,000 POLICY PRO- ❑ JECT LOC PRODUCTS-COMP/OP AGG $ 3000000 OTHER: AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB HCLAIMS-MADE AGGREGATE $ DED RETENTION$ 1 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N 124494445 7/13/2021 7/13/2022"X STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 B OFFICER/MEMBER EXCLUDED? Ix IN/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ NY State DBL DBL567527 1/01/2021 1/01/2022 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Rd THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Southold NY11971 AUTHO�RII�ZEED�REREPRESENTATIVE RolvY(.S. Fadi, ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD TATE Compensation workers' CERTIFICATE OF INSURANCE COVERAGE STAT Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1 b. Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c. Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e., Wrap-Up Policy) 823336604 2.Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Main Rd 3b.Policy Number of Entity Listed in Box"1 a" Southold, NY 11971 DBL567527 3c.Policy effective period 01/01/2021 to 12/31/2022 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/15/2021 By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 4C or 5113 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 1�� I III 1111111 Zoho Sign Document ID:FUYPH(;R4LXDHRYRTKN(iLTT55UXYX_UVF4DUHNNRZP5W Town.of Ssauthold January 4th, 2022 Building Departmentad Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Triolo Residence, 420 Beachwood Ln, Southold, NY 11971 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3 second gust, Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.7 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, OF N Ew Gennaro Anthony Giustra. P.E. P�� O A0 Great Eastern Services, Inc. g� PO Box 240 24 Harvey Rd Riverhead, NY 11901 2 �O 103443 Office: 631.543.9555 A�OFESS1pNP�. Mobile: 631.235.0189 Email: jerrygiustra@gmail.com ?oho Sign Document ID:FUYPHCR4LXDHRYRTKNGLTT55UXYX GVF4DQHNNRZP5W DCOfDF_ of= W0 i5'_ North Fork Table&Inr Y_,�� — ,RK, DESIGN t DRAFTING BY: % '3ELEMENT ENERGY LLC -0 INSTALL A 3,2,KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE TPIOLO RESIDENCE, sou"6,�- . REVIEW BY J.M. NA13CEP CERTIFIED -OCATED AT 420-bEACHWOOD LN, SOUTHOLD, NY 1 1971. Sparkhng P0,11, 051112-129 -HE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID -HROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. 'HE PV SYSTEM DOES NOT INCLUDE STORAGE DATTERIE5. REVISIONS DE5CRIPTION DATE REV Goose Creek Beac ORIGINAL 01-04-2022 3Y5TEM RATING 01111c alk"hneyd.ds .2 kW DC STC pec 0 fQUIFIVIENT SUMMARY 5 QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT FV MODULES 5 ffNPHA5ff IQ7FLU5-72-2-U5 MICRO INVERTERS ' IRONRIDGff XR 100 MOUNTING SYSTEM �e'�Iell r CONTRACTOR SHEET INDEX ELEMENT ENERGY, LLC. 'v-1 COVER 7470 SOUND AVE 'V-2 SITE PLAN \PROJECT. LOCATION MATTITUCK, NY 1 1952 'V-3 ROOF PV LAYOUT OF NEW 'V-4 STRUCTURAL/DETAILS t-SECTIONS 0 A 0 ELECTRICAL LICENSE # 43(589-H 'V-5 3-LINE ELECTRICAL DIAGRAM LICENSE # 52G(59-ME 'V-G. LABELSN INSPECTION REQUIRED GOVERN ING CODES 00 ?O 17 NATIONAL ELECTRICAL CODE. PPOJECr NAME )020 RESIDENTIAL CODE OF NEW YORK STATE. \5CE 7-1 G AND NFFA-70. 103445 W 2700—::j0 )NDERWRITER5 LABORATORIES(UL)STANDARDS 'OR &ANCY OR )SHA 29 CFR 191 0.269 SS% 2400 V Lu 2100 dSEIS UNLAWFUL, GENERAL NOTES 180 0 � gm CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT s WITHOUT CERTIFIC LLJ E) ,TO STARTING TO WORK AND SHALL FAMILIARIZE C�� 0 HE SITE PRIOR OF OCCUPANCY 0 > IM5ELf WITH THE INTENT Of THESE PLANS AND MAKE WORK > .GREE THE SAME. AERIAL VIEW . CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRE[) cz L C) .PPROVALS, PERMITS, CERTIFICATES OF: OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COM MENT5 AND APPROVAL 5TAMID 0 -1 45PECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, _J < 0 GENCIES HAVING JURISDICTION THEREOF, If REQUIRED. LLJ . ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION, ETC. ADEQUATE FOP,THE PURPOSES 0 CD ,LL RULES AND REGULATIONS Of THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO COMPLY WITH ALL CODES OF IV c) UR15DICTION. COMMENCING WITH WORK. NEW YORK STATE & TOWN CODE 0 1 1 EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR AS REQUIRED AND CONDITIONS If IN THE COURSE Of CONSTRUCTION A CONDITION EXISTS MAINTAINING SAFETY ON THE JOB SITE DURING THE APPROVED AS NOTED OF IHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS HE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS Of THE OCCUPATIONAL SAFETY AND DATE: /ue� B.P.# NGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT :ONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR.ADEQUATE AND PROPER BRACING, FEE: BY: mmuDm BOARD E5PON5115ILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY NOTIFY .BUILDING DEPARTMENT AT . SPIFFY NAME . ALL STRUCTURAL STEEL SHALL 13E A-36 AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT 765-1802-, 8 AM TO 4 PM FOR THE SO n7T-0—WAN-IMUSTEES A,BRICATED AND INSTALLED AS PER LATEST A.1.5.0 PECIFICATIONS. _-OLLOWING INSPECTIONS: --- CONSTRUCTION. Y.S.DEC ALL ELECTRICAL WORK SHALL BE BOARD Of FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE I. FOUNDATION - TWO" REQUIRED COVER NDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING FOR POURED CONCRETE Y5 CODES $ REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND 2. ROUGH FRAMING & PLUMBING COMMENCING WITH WORK. 3. INSULATION DPAW14G 5CALE :ONSENT Of THE ENGINEER WILL NEGATE THE ENGINEER'S13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS FE W1 E ,.EP,Tif ICATION Of THESE PLANS. WORK FROM THE SITE AND DISPOSE Of IN A LEGAL MANNER ON FINAL - CONSTRUCTION MUST .. THESE DRAWINGS AS IN15TRUCMENT5 Of SERVICE ARE AND A WEEKLY BASIS OR SOONER If CONDITIONS WARRANT. BE COMPLETE FOR C.O. JAN -1 1 2n99 N .T.5 . -HALL REMAIN THE PROPERTY Of THE ENGINEER WHETHER THE ALL CONSTRUCTION SHALL MEET THE 14. AT THE COMPLETION Of WORK, THE SITE TO BE CLEARED ROJECT F WHICH THEY ARE MADE 15 EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE REQUIREMENTS OF THE CODES OF NEW BU!LD7j',C DE=T. HEY ARE NOT TO BE USED ON ANY OTHEIR,PROJECTS OR, XTEN51ONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK 15 TO 13E COMPLETED TO THE YORK STATE. NOT RESPONSIBLE FOR I Ovvi"OF Sol--,XOLD SPIFFY NUMBER . CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION Of THE OWNER PRIOR TO REL.EA5E Of DESIGN OR CONSTRUCTION ERRORS. XISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. Fv_ I E5ULT Of HIS WORK. TAX MAP: 1000070001000054000 ?oho Sign Document ID:FUYPHOR4LXDHRYRTKNGLTT55QXYX_GVF4DQHNNRZP5W LEGEND DESIGN&DRAFTING BY: NT ENERGY LLC EXISTWG UTILITY METER ` REVIEW BYJELEMEM NABCEP CERTIFIE MAIN`SERVICE PANF1 O5 I 112-129 NEW PV SUB-PANELS A/C DISCONNEbT COMBINER �� oo INVERTERS 00 GND ELECTRODED ,O REVISIONS QO ° DE5CRIPTION DATE REV PV MODULE �jO ORIGINAL 0I-04-2022 RACKING RAIL D o ATTACHMENT POINT ..nn1;11 j j �o ---RAFTERS V" SOo ;Poo -4--ROOF PITCH ANGLE SUNRUN METER VENT PLUMBING VENT 6"x 36"GROUND ACCE55 TYP. K]SKY LIGHT CHIMNEY / •:' CONTRACTOR COMPOSITE SHINGLES GOOD CONDITION POTENTIAL SHADING ISSUE ENERGY,�TRIM/REMOVE AS NECESSARY / ELEMENT ,. � ,' ". R Y, LLC. 7470 SOUND AVE MATTITUCK, NY 1 1952 LICENSE # 4388941 LICENSE # 52G(59-ME / PROJECT NAME / ACCE55 ROOF z W './ W C) C) oh of NES = o 0 A �� r4,A O U co a� Gs � Qo o W CD - m = 14'-8211 m/ C) O 103443 v SSIONP 5HEET NAME 82 51TE PLAN NOTE .)THE ROOF SETBACWATHWAY SHALL NOT BE :SQUIRED TO ROOFS WHEN OPPOSING OR DRAWING5CALE \DJACENT ROOF IS ACCESS ROOF IN �j ACCORDANCE WITH 8324.6. I EXCEPTION OF /811 = I 1-011 1020 NYS RESIDENTIAL CODE �ON5TRUCTION NOTES ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 511EET NUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. ?.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. PV-2 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1000070001000054000 Zoho Sign Document ID:FUYPHGR4LXDHRYRTKNGLTT55QXYX_GVF4DQHNNRZP5W LEGEND DE51GN 4 DRAFTING BY: o EXISTING UTILITY METER ` ELEMENT ENERGY LLC MAIN SERVICE PANE NEW PV SUB—PANELS REVIEW BY J.M.NABCEP CERTIFIE A/C DISCONNECT 41 051112-129 COMBINER 00 INVERTERS GND ELECTRODE o �SrOo O , REVISIONS ME PV MODULE DE5CRIPTION DATE REV RACKING RAIL ,Oo Q ORIGINAL 01-04-2021 o ATTACHMENT POINT ,�Qo j O Oo ---RAFTERS ' .// v" 000 ,too i • f RODF PITCH ANGLE 3G"x 3G"GROUND ACCESS TYP. ' /`/, - / % •; /' SUNRUN METER XVENT OPLUMBING VENT SKY LIGHT , CHIMNEY COMPOSITE SHINGLES /,' CONTRACTOR GOOD CONDn10N POTENTIAL SHADING ISSUES / ! TRIM/REMOVE AS NECESSARY ELEMENT ENERGY, LLC. 7470 SOUND AVE MATTITUCK, NY 1 1 952 LICENSE # 43889-H LICENSE # 52G89-ME j• /, ACCESS ROOF /' / PROJECT NAME : NEW LLJ Qgo AGAG .p `, -• /.. ' . ; /;,.. . . , : ,.; ,' / ' • � :: '', �• %% W � 6� W o _ w i I o 0 - z I 1 I - O z 1-7 I LLQ 103443 !� I V Z p v � ° ss% OwO I I I I . 1f O = _5211 a/- O � f I N O IIII 1 i� l I NOTE .)THE ROOF SETBACK/PATHWAY SHALL NOT BE 10 11 :SQUIRED TO ROOFS WHEN OPPOSING OR Z \DJACENT ROOF IS ACCESS ROOF IN ACCORDANCE WITH R324.G. I EXCEPTION OF SHEET NAME ?020 NYS RESIDENTIAL CODE ARRAY#1 :ON5TRUCTION SUMMARY (5 MODULES 18°PITCH f�0 O F D ETA 8) QCELL Q.PEAK DUO BLK-ML G 10+ 400 WATT PV MODULES 132°AZIMUTH (DIMENSIONS: 74"X 41 . 1"X 1 .3") 8) ENPHASE IQ7PLU5-72-2-U5 MICRO INVERTERS 1 G) ATTACHMENT POINTS @ G4" O.C. MAX. DRAWING5CALE 55.5) LF IRONRIDGE XRI 00 MOUNTING SYSTEM. :OOF TYPE = ASPHALT SHINGLE (SINGLE LAYER) 1 /811 _ 1 1-011 �0N5TRUCTION NOTES .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE NITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS. ?.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH 5HEET NUMBER ANIMUM NEMA 3K RATING. �`v,_� 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE =IELD VERIFICATION. TAX MAP: 1000070001000054000 ?oho Sign Document ID:FUYPHCR4LXDHRYRTKNGLTT55QXYX_GVF4DQHNNRZP5W _OAD CALCULATION e ARRAY#I ITEM DESCRIPTION ARRAY#I DESIGN t DRAFTING BY: (RE3F Ridge Beam/Board 2"X 12" D. FIR ELEMENT ENERGY LLC MODULE WEIGHT(Lbs) 48.5 R Roof Rafter 2"X 10" D. FIR I G` 0.C. REVIEW BY J.M. NABCEP CERTIFIE #OF MODULES 8 (D) Deckln 5/8" PLYWOOD 05 1 1 1 2-129 of: NEW (P) Fitch 18, TOTAL MODULE WEIGHT(Lbs) 388.0 .�� yO (H) Horizontal 5 an of(R) 115 1" MAX. REV1510N5 TOTAL LENGTH OF RAIL(Ft) 55.5 `P�_Q0 A GG/G� �� DE5CRIPTION DATE REV ZAIL WEIGHT PER FOOT(Lbs) 0.68 =1�� ORIGINAL 0I-04-2022 TOTAL RAIL WEIGHT(Lbs) 37.7 n 1 W (RB) #OF 5TRANDOFF5 16 2 Z (R) WEIGHT PER 5TRANDOFF(Lbs) 2 703 � (D) TOTAL STANDOFF WEIGHT(Lbs) 32 A�4Q SS1ONP� � C I TOTAL ARRAY WEIGHT(Lbs) 457.7 I I 'DINT LOAD(Lbs) 28.6 I CONTRACTOR TOTAL ARRAY AREA(5cl Ft) 1 71.3 I I ARRAY DEAD LOAD 05/5cl Ft) 2,7 ELEMENT ENERGY, LLC. WIND DESIGN SUBJECT TO DAMAGE FROM i 7470 50 U N D AVE GROUND SEISMIC YANTER ICE BARRIER AIR MEAN FLOOD LOAD BEARING LL.SNOW Sped Topographic Special YYindbome DESIGN Frost DESIGN UNDERLAYMEi•,i7 FREEZING ANNUAL I MATTITUCK, NY 11952 wind debris line HAu�� LICENSE # 43889-H LOAD (mph) eHectsk 1 rn CATEGOR1fr Weathering' b Termite TEMP° REQUIREDh INDEI(I TEMPI ( ) 1 region zone depth I LICENSE # 52689-ME 20 130 NO NO NO B SEVERE 3 FT OD T 15'F YES HEAVY I ZONE 599 51'F IAANUAL J DESIGN CRITERIA" Winter Summer Altitude Indoor Design Heating I Eters[ion Latitude heating cooling correction factor design temperature cg temperature temperature difference ol I PROJECT NAME 108 FT 41"N 15"F 8S'F 1.00 Ar F 75'F 55'F (H) Cooling Wind Wind Coincident Daily Winter SummerW — I temperature difference velocity velocity wet bulb range humidity humidity I Z heating cooling W 11"F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GR X50%RH U =or SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING DETAIL n W 0 1. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth O ,trength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as W Z letermined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. 1. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction C) shall fill in the frost line depth column with the minimum depth of footing below finish grade. MODULE MOUNTING CLAMPO The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. ___ Q O 1. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined SOLAR MODULE J LL_.I = on a site-specific basis in accordance with Section R301.2.1.4. co The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York STAINLESS STEEL 3/8" State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also BOLT AND NUT O O DZ see Figure R301.2(1).] N The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. i. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the NP.IDGE ALUMINUM RAIL Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: i.The accompanying Flood Insurance Rate Map(FIRM), ALUMINUM"L"BRACKET ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. ALUMINUM FLASHING 5HEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. 1. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the l in this iction shall fill in this part of the le damming, lljurisdiction lP the rir Otherwise, hbwith aIZAT ejurisdictionshall fill in this partofthetablewiththe0yeaetun period afrez ng ndex(BFays)from Figure R4033(2)orfr me100,yer(99 percent) TKUCTUL value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." ASPHALT SHINGLE ROOF The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method 5/1 G"x G"STAINLESS (Base 32°F)." STEEL LAG BOLT WITH In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 2 1/2"MIN THREAD jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION SEALED DRAWING SCALE In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL 4500 "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) AS NOTED n. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. 1. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. 1. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. 5HEET NUMBER *) See Figure R301.2(4)B. � PV-4 TAX MAP: 1 000070001 000054000 MOUNTING DETAIL 1 ?oho Sign Document ID:FUYPHCR4LXDHRYRTKNGLTT55QXYX_GVF4DQHNNRZP5W DESIGN 4 DRAFTING BY: SOLAR ARRAY ON MAIN HOUSE 3.2 kW ELEMENT ENERGY LLC � (8)QCELL Q.PEAK DUO BLK ML-G 10+ 400 PV MODULES REVIEW BY J.M.NABCEP CERTIFIE05 I 112-129 (1)STRING OF(8) MICRO-INVERTERS '(I)STRING TOTAL TO UTILITY GRID REVISIONS STRING # I DE5CRPTION DATE REV ORIGINAL 0I-04-2022 - - - - ��0� NE�y 1 I N r- ------------ � BI-DIRECTIONAL LITY METER t- - ---- ��P�` O /Q C(��0;p O IJ PIHASE,240 V -- ---- ---- ------ ---- -- ENPHASE BRANCH * 2 N I MICRO-INVERTER CIRCUIT CABLE TYPICAL ENPHASE IQ7PLUS-72-2-US W 240 VAC. 1.21 A m 1 W 97.51/.CEC-WEIGHTED EFF. NEMA 6.UL L15TED TYPICAL 103443 " CONTRACTOR I sl MAIN MAIN SERVICE DISCONNECT I 240 V,200 A I ELEMENT ENERGY, LLC. I 747.0 SOUND AVE MATTITUCK, NY 1 1952 I LICENSE # 43889-H I 2-POLE PV BREAKER 240 V.15 A LICENSE # 52G(59-ME SNALL BEINSTALLS MAIN SERVIC DSSA5 FAP A5?05SCONNOM 1 ' N fl I OA r I /JI1 I 1 ' 1 PROJECT NAME I 1 ISA MAIN SERVICE PANEL 1 1 I I-FI-1.3-W I 240 r----------------------------------------------------- ---------------- VAC W � -� 1 I I 200 A AC COMBINER BOX z 240 VAC.80 A I I N W NEMA 3R UL USTED m (I)20 A DOUBLE POLE BREAKERS I GU EXISTING GROUNDING L[ -----------� i ELECTRODE SYSTEM Q O cn LUz I I QI WIRE 4- CONDUIT SCIIEDULE0 0 CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% 0 LLJ 1.1). # ORIGIN DESTINATION SIZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DERATE DISTANCE co0 O 310.1 5(B)(3) 310.I5(B)(2a)A3c) IL'L O O INVERTERS COMBINER PANEL AWG#10 I 2 I USE-2/PV Wire AWG#8 I BARE CU FREE AIR I" 55°C 0.84 1 10 FT 0.8% OR EMT �. 2 COMBINER PANEL AC DISCONNECT AWG#10 I 3 I THWN-2 AWG#8 1 THWN-2 CU PVC I" 459C 0.95 25 FT 0.6% - ,ICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS j)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampaclty Calculation CONFIGURATION _.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90QC WET ENVIRONMENT. [NEC 69Ource Circuit it W e of st ity Calculation .56) = 12.I A 3-LINE DIA. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY Modules per String 8 TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. AWG#10,ampacity'Temp Derate = 26.88 A 88 A> 1 2.1 A, therefore DC wire size is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 26. Number of Inverters 8 COMPLY WITH NEC 110.26. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 1 2.1 A Record low temp -100C FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE55ORIE5 TO FULFILL AWG#10,ampacity'(Temp Derate)'(Conduit Fill Derate) = 38 A Voc Temp Coefficient -0.240le-C DRAWING SCALE APPLICABLE CODES AND STANDARDS. 38 A > 1 2.1 A, therefore AC wire size 15 valid. DC SYSTEM SPECIFICATIONS CALCULATIONS �.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Operatinq Current 10.8 A =(#of Strin s)'(Im ) I . . T. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. O eratin V Volta e 37.13 V =(#modules in series)'(Vm ) I I 3.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Max.System Voltage 49.6 V = (#modules in 1)'(Lo Temp##o-C-25))'(Voc))+(Voc)] SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Clrcult Current 13.9 A =(#of strip 5)'(Isc)'(I.25)per Art. 69O.8(A)(1) 3.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. AC SYSTEM SPECIFICATIONS SHEET NUMBER 0.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) Max AC Output Current 1 2.1 A PV-5 DR O eratin AC Voltage 240 V 0.)THE DC SIDE OF THE PV SYSTEM IS UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000070001000054000 Zoho Sign Document ID:FUYPHCR4LXDHRYRTKNGLTT55QXYX_GVF4DQHNNRZP5W SERVICE METER I O IO DE51GN E DRAFTING BY: INSTALLATION NOTE ELEMENT ENERGY LLC REVIEW BY J.M.NABCEP CERTIFIE SOLAR PV SYSTEM PHOTOVOLTAIC PHOTOVOLTAIC SYSTEM ( I ) ALL LADEL SHALL BE INSTALLED IN 051112-129 1.! SOLAR BREAKER �; EQUIPPED WITH ---- D• • ACCORDANCE WITH THE 201 7 NEC RAPID SHUTDOWN ® •• " REQ U I REM ENTS. REvisioNs OPERATING DE5CRIPTION DATE REV •R (2) ALL LOCATIONS ARE APPROXIMATE AND ORGINAL 0I-04-2022 SOLAR AC LOAD CENTER - OUT51DEDONOT RELOCAiETHIS SHORT CIRCUIT CURRENT A REQUIRE FIELD VERIFICATION. OVERCURRENTDI:ViCE (3) LABELS, WARNINGS) AND MARKING O3SHALL BE IN ACCORDANCE WITH NEC TURN RAPID SHUTDOWN swrrCH TO O THE•OFFP=ONTOMDOVINQ 1 1 0.2 I (B). I PV SYSTEM AND REDUCE _'- SHOCKHAZAMMI WTz-ARMY _ , AC DISCONN C; POWER 7O CAUTION IM (4) THE MATERIAL USED FOR MARKING SERV=6 ALSO SUPPLIED FROM 7*/FGCN -CMOLL LOMW=SOUS M V TEDAt&4OWUH DO? MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - INSIDE O COMPLIANCE WITH NEC 1 10.2 1 (13)(3). CONTRACTOR Fa (5) THE PV SYSTEM CIRCUIT CONDUCTORS ® OO REM O 1 1 70VERCtRR7ENT7DEVM, 7DUPJ-POW7ERNG PY SHALL BE LABELED INSTALLED IN ELEMENTENERGY, LLC. BY�'dI 7UU UPPLYCOMPLIANCE WITH NEC 690.3 I . �47o soUND AVE EXCLUDIN''S TY GRID MATTITUCK, NY 1 1952 UPOVSICURRENT AR LICENSE # 43889-11 DEVICE,SHALL W9 EXCEEDELECTRIC SYSTEM CONDUIT - INSIDE BUILDING AI$PACRYOFBUSSAR -_. - I LICENSE # 52689-ME ----------------------- O O 11IS RNER ALER SOS��BAPROJECT NAME ELECTRIC SHOCI!HAZARD i PHOTOVCOMBIL PSTfl�A HOTOVOLTAIC SYSTEM J TERMI ON THE H TtOPEN PO LINEANDD i ANEL � LOAD S MAY d�ENERGIZED , DO NOT ADD LOADS LLQ CONDUIT - OUTSIDE BUILDING Z (3 LLJ 7PSVOURCES�UTIMYGRID MING `• • ' o O SUPPLY O z AND LL A RIC SYSTEM Q MAIN SERVICE PANEL - OUTSIDE 0 ACAUTIONSOLARCIRCUIT Q —I- _ —iO LLJ SOLAR ELECM SYSTEM cD>sr�CIED j (L O PHOTOVOLTAIC ~ N O © AC DISCONNECT ( ) OPERATING CURRENT AMPS MAIN SERVICE PANEL - INSIDE RAMP, INffiGIIIIIIIIIIIII 1 OPERATING I POWER SOURCE II OUTPUT CONNECTION ® O I DO NOT RELOCATE THISof URRENT ICE NEw y 5F1EET NAME l OVERCDEVVLA _ ��0 A c�Gs0 CO LABELS AC DISCONNECT/BREAKER - W N -- ,p� l DRAWING 5GALE O O O ��ARO103445NP N . I .S. �ESSIO 5HEET NUMBER PV-6 TAX MAP: 1 000070001 000054000 IR 'ON RIDGE Flush Mount System Built for solar's toughest roofs® IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified • All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. --- XR Rails (� ~ ~ XR10 Rail XR100 Rail XR1000 Rail Bonded Splices Alow-profilemountingnai| The ultimate residential A heavyweightmounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. ^ G'apanningcapabi|ity ^ 8'apanningoapabi|hx ^ 12'opanningoopabi|itv ^ 8eK'dhUingoorewo ^ Moderate load oopobi|ih/ ^ Heavy load capability ^ Extreme load capability ^ Varying versions for rails ^ Clear and black finish ^ Clear and black finish ^ Clear anodized finish ^ Forms secure bonding --- Clamps & Grounding (D LIFOs Stopper Sleeves Grounding Lugs Micmminverter Kits � . ' Universal Fastening Objects Snap onto the UFO toturn Connect arrays to Mount K8|aor POs to XR bond modules torails. into abonded end clamp. equipment ground. Rails. ^ Fully assembled & |ubmd ^ Bonds modules 0orails ^ Low profile ^ Bonds devices torails ^ Sing|e, universal size ^ Sized to match modules ^ Single tool installation ^ Kit comes assembled ^ Clear and black finish ^ Clear and black finish ^ Mounts in any direction ^ Listed to UL 2703 --- Attachments S FlashFmot2 Conduit Mount Slotted L-Feet Bonding Hardware ` Flash and mount XRRai|a Flash and mount conduit, Drop-in design for rapid rail Bond and attach XRRails with superior waterproofing. strut, orjunction boxes. attachment. toroof attachments. ^ Twist-on Cap eases install ^ Twist-on Cap eases install ^ Secure rail connections ^ T&Square Bolt options ^ Wind-driven rain tested ^ Wind-driven rain tested ^ Slot for vertical adjusting ^ Nut uses 7/16''socket ^ Mill and black finish ^ Secures 3/4"mri^conduit ^ Clear and black finish ^ Assembled and lubricated Resources fullyDesign Assistant NABCEP Certified Training Go from rough layout to / engineered system. For free. while learning more about our systems. oto Iron Rid ge'cmmn/demign Go to Iron Ridge.cbm/trai ni ng powered by 0 i � . A YR � Q EUPOPE Warranty X20 Q CELLS Product&Perlamarce Yield Security BREAKING THE 207,EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of v� the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Oz Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect and Traceable Quality Tra.QTMt. EXTREME WEATHER RATING (� High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION Format 74.0 in x 41.1 in x 1.26 in(including frame) (1879 mm x 1045 mm x 32 mm) 744(1679 mm) s.e(3as.6mm) 4z.e•poeamm) Weight 48.5lbs(22.Okg) i :4ea(ufiomm) L Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with �-- - anti-reflection technology 4G d,gPdn n 0.19•(46nn) rmm° Back Cover Composite film 3s2(eoemm) Frame Black anodized aluminum ® 4u•po4smm) Cell 6 x 22 monocrystalline G.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes LeOd� :49X( SO-) Cable 4mm2 Solar cable;(+)2_49.2in(1250mm),(-)2_49.2in(1250mm) � 9.Dmmeaehdes _ Connector Staubli MC4;IP68 4.M=V,g SIM(DETAIL A) -E.(32-) DETAILA 0.63•(1 Iem{)T 0.66•(24.6mm)I -1-0.33•(&5-) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/-0 W) Power at MPP' PMPP [W] 385 390 395 400 405 E Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 E Open Circuit Voltage' Voc [V] 45.19 45.23 45.27 45.30 45.34 .5 Current at MPP IMPP [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VMPP [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' q [%] 2_19.6 >19.9 2_20.1 2_20.4 2_20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PMPP [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Voc [V] 42.62 42.65 42.69 42.72 42.76 .E Current at MPP IMPP [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMPP [V] 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances PMPP±3%;Isc;Voc±5%at STC:1000 W/mz,25±2°C,AM 1.5 according to IEC 60904-3•2800 W/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98%of nominal power during -`uo T Z re °amrsa----rc°wermci 6 first year.Thereafter max.0.5% z ><o m ----- ------------------------------ degradation per year.At least 93.5% u,eo w of nominal power up to 10 years.At LL ?z` least 86%of nominal power up to w go 25 years. r• 80 --r-----------I----- ----- � ea 5 z o All data within measurement toleranc- w ---------------------- es.Full warranties in accordance with eo a the warranty terms of the Q CELLS mo 4Do e6D soo 400D o 0 eo sales organisation of your respective N0.ADIANCEIW/m'] 0 e io ss m m country. s,d�,°m nae�ma maaowwmm°. YEARS Typical module performance under low irradiance conditions in In e�oweaa° �°2mAl.:swxal comparison to STC conditions(25°C,1000 W/m2) In TEMPERATURE COEFFICIENTS o Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Vocp [%/K] -0.27 c? Temperature Coefficient of PMPP y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) m 0 D PROPERTIES FOR SYSTEM DESIGN ° a w Maximum System Voltage VE,.s [V] 1000(IEC)/1000(UL) PV module classification Class II oa m Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 m Max.Design Load,Push/Pull3 [IbS/ft2] 75(3600 Pa)/55(2660 Pa) Permitted Module Temperature -40°F up to+185°F o Max.Test Load,push/PUII3 [lbs/ft') 113(540OPa)/84(4000Pa) on Continuous Duty (-40°C up to+85°C) a m m 'See Installation Manual U QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION m UL6173QCE-compl-T IE 63• Ise- $ IEC 6y Controlle15:2016,I C 1730 Rheinland, cau-S OQIEC 61215:2016,IEC 81730:2018, mU.S.Patent No.9,893,215(solar cells), CE TWMdnlmtl Horizontal 76.4in 43.3in 48.Oin 1656lbs 24 24 32GICPV Certification ongoing. packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules 1.erm _ UL617M 0-111 a Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwhe O CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1949 748 59 961 EMAIL inqulry@us.q-cells.com I WEB www.q-cells.us Data Sheet ' r Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready pEnphase IQ 7 MicroTM and Enphase IQ 7+ Micro'°" IQ 7 and IQ 7+ dramatically simplify the installation process while `� achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'M, Enphase IQ Battery', and the Enphase Enlighten TM monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple .": Faster installation with improved,lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014&2017) —.1k 0.1 i Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed eFNPHASF- TQ0 Smart Grid Ready • Complies with advanced grid support,voltage and zzt . ,. frequency ride-through requirements + Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U� *The IQ 7+Micro is required to support 72-cell modules. 0:1 To learn more about Enphase offerings,visit enphase.com `d EN PHAS E. Enphase IQ 7 and IQ 7+ Microinverters ` INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235W-350W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input A DC voltage 48V 60 V Peak power tracking voltage 27V-37V 27V-45V Operating range 16 V-_48 V 16 V-60 V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L L)voltage/range2 .240 V/ 208V/ 240 V/ 208V/ 211-2.64 V 183-229 V .211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over-3- cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0, Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-6-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 p (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.com/en-us/support/module-com p atibilit y. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com V EN PHAS E. ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc 2018-05-24