Loading...
HomeMy WebLinkAbout21699-zFORM NO. 4 TOWN OF SOUTNOLD BUILDING DEPARTMENT office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-26389 Date: 04/20/99 THIS CERTIFIES that the building FUEL TANKS Location of Property: 1515 YOUNGS AVE (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 60 Block 1 Lot 6 Subdivision Filed Map No. -- Lot No. -- conforms substantially to the Application for Building Permit heretofore filed in this office dated APRIL 2, 1993 pursuant to which Building Permit No. 21699-Z dated OCTOBER 8, 1993 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is INSTAn?.~TION OF FUEL TANKS, & CONSTRUCTION OF CONTAINMENTS WITH ROOF OVER LOADING AREA AS APPLIED FOR. The certificate is issued to ROMANELLI REALTY, INC. (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED Rev. 1/81 N/A N-337389 N/A 12/22/94 FO~M NO.3 TowN OF$OUTHOLD BUILDING DEPARTMENT $OUTHOLD, N.Y. N~ 21699 Z BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permisslon Is hereby granted to: ~" '~~-"-'~ .... ...~z~...~Z_~....~ ....... ~~ ................... .......... at premiss ~ocat~l at ............................................................................................................................... CounIvTax Map No. 1000 Section .......... ~ ....... Block ........ .,/ ............... Lot No ...... ~ ................... pursuant to application dated.....~'...../..~.. ........................................ '.., 19.~,....;..., and approved by the Building Inspector. d~--~- Fee $ ,/"'~ 7,..~...,~ Rev. 6/80/80 BLD . · D ~; Form No. 6 TOWN OF SOUTROLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter OR ink and submitted to the building inspector with the following: for new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and Vpre-existing" land uses: 1. Accurate sBrvey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00. Businesses $50.00. 2. Certificate of Occupancy on Pre-existin~ Buildin~ - $100.00 3. Copy of Certificate of Occupancy - $20200 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Resident Commercial $15. Date ................................ New Construction ........... Old Or Pre-existing Building ....... ~ ......... Location of Property...Z~../.~.. o 2~/?y~...~.~C. ..... .~..~.~.".~.~../~. .............................. House No. Street Hamlet · -"LOt County Tax Map No 1000, Section .. ~ ...... Block ...................... Subdivision .................................... Filed Map ............ Lot ...................... Permit No~.~'.~ .... Date Of Permit .............. .. Applicant ........................ . . . .. Health Dept Approval Underwriters Approval ~ .... Planning Board Approval ........................ ../... Request for: Temporary Certificate .......... Final Certicate ..... Fee Submitted: $ .~. ~ .~.~. ~). ............... ]. s-?'5 (0 ? ..................... THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITy ~-- 85 JOHN STREET, NEW YORK. NEW YORK 10038 Date DI~CI~IB~-'R 22,1994 ~pplicatlon No. on file 86277094/94 N 337389 THIS CE~IFIES THAT B~T ~L~ ~C., 1515 YO~ A~, ~, N.Y. ~s exami~ on DE~ER ~9,1994 ~t Rx~ RXT~ DRYERS FURNACE MOTORS FUTURE APPUANCE FEEDERS SERVICE DISCONNECT S E R V OTHER APPARATUS: MOTORS:2-15 H.P. ,1-25 H.P. ,1-10 H.P. PANELBOARDs: 1-1OO CIR. G.F.C.I:-i MULTbOUTLET DIMMERS SYSTEMS NO. OF FEET C E E, E. C. O. ELECTRIC CORP. 35650 COUNTRY RD.48 PECONIC, NY, 11958 LIC.#2816 E ~ 11 P~r__. This ca,ti(kote must not be aJtered in any monner; return to the office of the ~oard if incorrect. Inspectors may be identified by their credentials. 1 174 THE NEW YORK BOARD OF FIRE UNDERWRITERS PAG 1 BUREAU OF ELECTRICITy ~ 85 JOHN STREET. NEW YORK, NEW YORK 10038 Dat~ DECEMBER 22,1994 ~Apptication No. o, fle 86277094/94 N 337389 THIS CERTIFIES THAT Only the e~tr~] equil~ment as descrlb~d below and introduced by tAe ~ppllc~t named on the above application nur~ber in the prern~e~ of BURT RELIABLE INC., 1515 YOUNGs AVENUE, $OUTHOLD, N.Y. in the yotlmring location; [] Basement [] I,t Ft. [] 2,,d Ft. OUT/BARN .%~t~o, Bto~k t~es examined on DECEMBER 19,1994 Lot and found to be in compliance with the National Electrical Code. RX~O~ ~ EANGF.$ ~ SWlTClA___.~ ~ · RX?UI~ES -- I~NGE$ COOK~H~ O~KS OVENS iSM WASNE~S F-XNAUS? EAN SER. DISCONNECT 60 AMP TYPE CB-1 SER. DISCONNECT t00 AMP TYPE CB-1 SER. DISCONNECT 150 AMP TYPE CB-1 4~ AMP DISCOkrNECT PANEL-1 PNEUMEREATOR TANK ALARM SYSTEM-1 SIZE 1 MOTOR STARTERS 60 AMP-3 ~IZE 3 MOTOR STARTERS 1OO AMP-1 10~ AMP S/S-1 60 AMP S/S-3 <<< Continued on Page 2 >>> ...................... eam any monner~o the office of the Board i~ incorrect. Inspectors may be identified by their credentials.- ~i 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] FRAMING [ ] ROUGH PLBG. [ ] INS~JL~ON [ ~]~NAL [ ] FIREPLACE & CHIMNEY 765-1802 BUILDING DEPT. . INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION ;ZND [ ] INSULATION [ ] FRAMING [ ] FINAL DATE FOUNDATION 2. (2nd) ROUGH FRAME & ·PLUMBING INSULATION FERN. STATE ENERGY CODE FINAL ADDI' COMMENTS: 2490 Kayron Lane North Bellmore, New York 11710 516-826-4707 fax 516 679-8565 Buds Reliable, Inc. 1515 Youngs Avenue Southhold, New York 11971 August 10, 1998 Subject ' Canopy Construction Gentlemen, Attached herewith are two drawings depicting modifications to the existing construction. Both are signed and dated 7/23/98. Please note the original design was followed accurately and only modified to meet proposed expansion needs of the site. Design is to codes and standards of the local and regulatory departments of Southhold. n, P.E. 351.0u 3"PLATE PLAN OF CANOPY- NO SCALE NEW Wl 0'1 2 NEW W1 0'1 2 EXISTING Sl 2 TYP KNEE BRACE L31/2'31/2*3/8" TYP .~..1/4TYP*5 3/8"PLATE TO COLUMN WEB h .... J ~r ~ '~1~.~,, BOT SIDE~ r~ SECTION s _c-r,ON ~ BURTS RELIABLE YOUNGS AVE / of DE~ LOAD - 30 PSF $OUTHHOLD, NY EXISTING Wl 8 NEW Wl 0'1 2 NEW W1 0'1 2 -~3/8" PLATE P 4 METAL DECIDING WELD 3/8"PLATE TO COLUMN WEB BOTH SIDES KNEE BRACE L31/2'31/2'3/8" SECTION 2-2 NEW WF 10'12 T & B 3/8" PLATES- MOMENT CONNE( EXISTING Wl 8 EXISTING W 1"0'-~----. ....... NEW KNEE BRACE 1/4" FILLET WELD AT PLATE, TUBE AND NEW BEAM SECTION 3-3 BURTS RELIABLE ' YOUN~SAVE 2 2 DESIGN SNOW LOAD = 30 PSF ;. SOUTHHOLD, NY of PLANNING BOARD MEMBERS BENNETT ORLOWSKI, JR. Chairman WILLIAM J. CREMERS KENNETH L. EDWARDS GEORGE EITCI-IIE LATHAM, JR. RICHARD G. WARD PLANNING BOARD OFFICE TOWN OF SOUTHOLD Town Hall, 53095 Main Road P.O. Box 1179 Southold, Now York 11971 Fax (516) 765-3136 Telephone (516) 765-1938 TO: FROM: RE: DATE: Gary Fish, Building Inspector Robert G. Kassner, Site Plan Reviewer Burrs Reliable Youngs Avenue SCTM# 1000-60-1-6 February 24, 1998 The Planning Board has field inspected the above site for the issuance of a Certificate of Occupancy. The Board recommends that a Sugar Maple or an Oak be planted instead of the Bradford Pear shown on the approved plan. If this is satisfactory with the applicant, and planted when the weather permits, the Board recommends that a Certificate of Occupancy can be issued at this time. cc: Edward Forrester Town Hall, 53095 Main Road P. O. Box 1179 Southold, New York 11971 Fax (516) 765-1823 Telephone (516) 765-1802 OFFICE OF THE BUILDING INSPECTOR TOWN OF SOUTHOLD TO: FROM: DATE: RE: ROBERT KASSNER, PLANNING BOARD GARY J. FISH, BUILDING INSPECTOR OCTOBER 29, 1997 Building Permit #21699-Z Premises @ 1515 Youngs Avenue, Suff. Co. Tax Map #1000-60-1-6 Southold, N.Y. Due to the recent Freedom of Information request filed by Patricia Parvis, dated October 17, 1997 of Freudenthal & Elkowitz Consulting Group, Inc., it has been brought to the attention of the Building Department that the above building permit does not have a Certificate of Occupancy because it lacks final Planning Board Approval. Please advise me as to the status of the final approval so that Certificate of Occupancy can be issued. GJF:gar PLANNING BOARD MEMBERS Bennett Orlowski, Jr., Chairman George Ritchie Latham, Jr. Richard G. Ward Mark S. McDonald Kenneth L. Edwards Telephone (516) 765-1938 PLANNING BOARD OFFICE TOWN OF SOUTHOLD SCOFF L. HARRIS Sapervisor Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971 Fax{S16) 765-1823 August 11, 1993 Gary D. Matz, P.C. Cashin Associates, P.C. 1200 Veterans Memorial Highway Happauge, NY 11788 RE: Site Plan for Burt's Reliable, Inc. Youngs Ave., Southold Zoning District: Light Industrial (LI) SCTM# 1000-60-1-6 Dear Mr. Matz: The Planning Board has received the site plan for Burt's Reliable, Inc. dated July 26, 1993. The following changes must be made before the Board can continue with it's review: 1. Sidewalk, grass median strip, curb cut and curbing on Youngs Avenue. 2. One street tree on Youngs Avenue. e Evergreen buffer between fuel tanks and railroad tracks. If you have any questions, or require assistance, please contact this office. cc: Thomas Si~erel'y~, / ~/C~i~m~adnG· Ward Fisher, Building Inspector DEPARTMENT OF' HEALTH SERVICES COUNTY OF SUFFOLk ROBERT J. (~AFFN£y SUFFOLK COUNTY EXI=CUTIVI; April 27, 1993 Cashin Associates, P.C. 1200 Veterans Memorial Hwy. Hauppauge, NY 1~788 Attn: Gary Matz Re: Bert's Reliable Fuel Oil -.SCDHS JOB NO. H/~9~-337R~ $CDHS ID No. ~0-0029 Gentlemen: Enclosed please find plans submitted to this office for the above referenced project. These plans have been found to meet the standards of Article ~2 Of the Suffolk County Sanitary Code and have therefore been approved for construction as noted. Contact Mr. John Gladysz of this off,ce at 854-2524, at least $8 hours prior to starting construction, to arrange the required · nspections. Toxic or hazardous materials may not be put into the storage faciliCy until this Department gives final installation approval and issues a permit to operate. If you should have any questions in this matter, feel free to contact me at (516)854-2540. eno. Very truly yours, ~Me~~ Public Health Engineer SUFFOLII~'N~UNTY DEPT, OF HEAL' -- APPLICATION PERMIT TO CONSTRUCT ABOVE/UNDERGROUND TOXIC/HAZARDOUS LIQUID STORAGE TANK SYSTEM AND DRUM STORAGE FACILITIES [~]ABOVE GROUND TANK [~]UNDERGROUNO TANK PROPOSED STORAGE SYSTEM IS: [-~ DRUM/BULK STORAGE r-~ OTHE R (SPECIFY- I.O. COOE BURT' RELIABLE FACILITY NAME. ADDRESS OF PROdECT OFFICAL USE ONLY S,C,D.H.S. JOB N~. OATE RCV'D REQU'D FEE DATE FWD 1515 YOUNG'S AVENUE (NO.) (STREET) SOUTHOLD NEW YORK 11971 (CITY) (STATE) TAX MAP N~ .SECTION BLOCK LOT ,,, 1000 60 I 6 FACILITY OWNER OWNER'S ADDRESS (ZIP) BURT'S RELIABLE, INC. (NO.) (CITY) PHONE NI 765-3767 PERS. ON TO CONTACT FOR THIS PROJECT ADDRESS IF DIFFERENT FROM FACILITY OWNER PHONE NI 454-i630 . FARi,iiNGDALE, (STREET) (STATE) PAT ROMANELLI 374 FULTON STREET (NO.) (STREET) NEW YORK 11735 (ZIP) Total capacity I CERTIFY THAT ALL INFORMATION SUPPLIED HEREON AND ATTACHED HERETO IS TRUE TO _T-~E BEST OF MY KNOWLEDGE. ~ PAT ROMANELLI 10/27/92 ~ 0ATE OFFICAL USE ONLY THIS APPLICATION WITH ATTACHED PLAN/$ &~O I~EPORTS HAS BEEN R[VIEWEO AND APPROVEO FOR CONSTRUCTION ,,0..,-. o, .,.Dy,.....,.'.. o.,. BRIEFLY OESCRIBE PROJECT: Fuel 0il Depot with 4 tanks surrounded by a concrete containment area. of the tanks is 95,000 gallons. (CITY) (STATE) (ZIP) PLANNING BOARD MEMBERS Bennett Orlowski, Jr., Chairman George Ritchie Latham, Jr. Richard G. Ward Mark S. McDonald Kenneth L. Edwards Telephone (516) 765-1938 PLANNING BOARD OFFICE TOWN OF SOUTHOLD SCOTT L. HARRIS Supervisor Town Hall, 53095 Main Road P.O. Box 1179 Southold. New York 11971 Fax (516) 765-1823 November 9, i992 ·' Gary D. Matz, P.E. Cashin Associates, P.C. 1200 Veterans Memorial Highway Hauppauge, NY 11788 RE: Request for site plan waiver Burt's Reliable, Inc. Youngs Avenue, Southold Zoning District: Light Industrial (LI) SCTM~ 1000-60-1-6 Dear Mr. Matz: On October 30th, The Planning Board received your letter and revised plans o~ October 6, 1992, incorporating the changes the Board had requested in its letter to you of July 2, 1992, (copy enclosed). The Board will grant the waiver in accordance with your letter and accompanying site plan which we received on October 30, 1992. If you have any questions, or require further information, please contact this office. cc: Very truly yours, Bennett Orlowski, Jr. Chairman Victor Lessard, Principal Building Inspector ~ July 2, 1992 Gary D. Matz~ P.E. Project Civil Engineer Cashin Associates, P.C. 255 Executive Drive Plain view, NY 11803 RE: Request for site plan waiver Burt's Reliable, Inc. Youngs Avenue, Southold Zoning District: Light Industrial (LI) SCTM~ 1000-60-1-6 Dear Mr. Matz: This letter will confirm your telephone conversation of 3uly 2, 1992, with staff member Robert Kassner regarding the above referenced property. You had indicated the following changes would be made to your submission of June 17, 1992: The northernmost tank will be moved in line with the other three tanks so that there is sufficient space to back a truck out of the garage. Any possible outdoor lighting will be shown on the plan. The lighting will be shielded to the premises. Street trees and shrubs will be planted along the south side of the property facing the railroad tracks, YoungsAvenue, and between Burts'Reliable and Agway. A sketch of any proposed outdoor sign, showing dimensions and color. if you have any questions, or, require further information, please contact this office. Very truly yours, Bennett Orlowski, Chairman cc: Victor Lessard, Principal Building Inspector Cashin Assooiates, P.C. 5ngineers 8nd Archi~eots Hauppauge · Brewster May 3, 1993 Mr. Victor Lessard, Principal Building Inspector Office of Building Inspector Town of Southold Town Hall P.O. Box 1179 Southold, NY 11971 Re: Request for Building Permit Burt's Reliable, Inc. YounQ's Avenue, Southold SCTM# 1000-60-1-6 Dear Mr. Lessard: In response to your letter dated April 28, 1993, transmitted herewith for your review is a letter from Bennett Orlowski, dated November 9, 1992, informing the undersigned that the Planning Board has waived the site plan review for this project. A copy of this letter was simultaneously sent to your attention at that time. Also transmitted again is the Building Permit application and a check for the application fee $1,275.00 (based on a total new construction area of 5,500 s.f.). These plans have been approved by the Suffolk County Health Department and a copy of the approved plans and permit to construct are transmitted herewith. If you have any questions, please contact the undersigned at (516) 348-7600. Thank you for you cooperation, Very truly yours, CAS , ASSOCZ^TES, i' C. Civil Engineer cc: Pat Romanelli 2049.1 [essard.vl 1200 Veterans Memorial Highway · Hauppauge, NY I 1788 · (516) 348-7600 · FAX (~1 ~) 348-7601 PLANNING BOARD MEMBERS Bennetl Orlowski, Jr,, Chairman George Ritchie Latham, Jr. Richard G, Ward Mark S. McDonald Kenneth L. Edwards Telephone (516) 765-1938 PLANNING BOARD OFFICE TOWN OF SOUTHOLD SCOTT L. HARRIS Supervisor Town Hall, 53095 Main Road P.O, Box 1179 Southold, New York 11971 Fax (516) 765-1823 November 9, 1992 Gary D. Matz, P.E. Cashin Associates, P.C. 1200 Veterans Memorial Highway Hauppauge, NY 11788 RE: Request for site plan waiver Burt's Reliable, Inc. Youngs Avenue, Southold Zoning District: Light Industrial (LI) SCTM# 1000-60-1-6 Dear Mr. Matz: On October 30th, The Planning Board received your letter and revised plans of October 6, 1992, incorporating the changes the Board had requested in its letter to you of July 2, 1992, (copy enclosed). The Board will grant the waiver in accordance with your letter and accompanying site plan which we received on October 30, 1992. If you have any questions, or require further information, please contact this office. cc: Victor Lessard, Very truly yours, Bennett Orlowski, Jr. Chairman Principal Building Inspector PLANNING BOARD MEMBERS Bennett Orlowski, Jr., Chairman George Ritchie Latham, Jr. Richard G. Ward Mark S. McDonald Kenneth L. Edwards Telephone (516) 765-1938 PLANNING BOARD OFFICE TOWN OF SOUTHOLD SCOTT L. HARRIS Supervisor Town Hall, 53095 Main Road P,O. Box 1179 Southold, New York 11971 Fax (516) 765-1823 19 RE: Lead Agency Coordination Request Dear Reviewer: The purpose of this request is to determine under Article 8 (State Environmental Quality Review Act-SEQRA) of the Environmental Conservation Law and 6 NYCRR Part 617 the following: 1. Your jurisdiction in the action described below; 2. Your interest in assuming the responsibilities of lead agency; and 3. Issues of concern which you believe should be evaluated. Enclosed please find a copy of the proposal and a completed Environmental Assessment Form (CAF) to assist you in V. our response., /~ Project Name:. ~ ~/~ ,L~ ,¢~_~_/~ ~~ ,~. ,,~ . Requested Action: SEQRA Classification: ( , ) Type I ~ (~-) Unlisted Contact Person: ~/~, ~'/~-/7//~4 "- (516)J765-1938 The'lead agency will determine the need for an environmental - impact statement (EIS) on this project. Within thirty (30) days of the date of this letter, please respond in writing whether or not you have an interest in being lead agency. Planning Board Position: This agency wishes to assume lead agency status for this action. This agency has no objection to your agency assuming lead agency status for this action. ( ) Other. ( See comments below). Comments: Please feel free to contact this office for further.information. Chairman cc: Beard of Board -~ ~ Building' Department Southold Town Board ~6 Suffolk County Dept. of Health Services NYSDEC - Albany $~C~ Dept. of ~b~-i~ U~ F~---A ~ my ' ' tiun * Maps are enclosed for yodr review Coordinating agencies PLANNING BOARD MEMBERS Richard O. Ward, Chairman George Rltchle Latham, Jr. Bennett Orlowski, Jr. Mark $. McDonald Kenneth L. Edwards Telephone (516) 765-1938 , SCOTT L. HARRIS ~ Supervisor ~ ;~[ Town Hall, 53095 Main Road ~ .... P.O. Box 1179 PLANNING BOARD OFFICE F~x (516) 765 - 1823 TOWN OF SOUTHOLD State Environmental Quality Review NEGATIVE DECLARATION Notice of Determination Non-Significant September 13, 1993 This notice is issued pursuant to Part 617 of the implementing regulations pertaining to Article 8 (State Environmental Quality Review Act) of the Environmental Law. The Southold Town Planning Board, as lead agency, has determined that the proposed action described below will not have a significant effect on the environment and a Draft Environmental Impact Statement will not be prepared. Name of Action: Burt's Reliable SCTM%: Location: SEQR Status: 1000-60-1-6 Youngs Ave., Southold Type I ( ) Unlisted ( X ) Conditioned Negative Declaration: Yes ( ) No (X) Description of Action: This site plan is to replace above ground storage tanks that were removed in 1991 with above ground storage tanks of the same capacity conforming with current Health Department Standards. Page 2 SEQRA Negative Declaration - Burt's Reliable September 13, 1993 Reasons Supporting This Determination: The project involves the replacement of above ground storage tanks with above ground tanks of the same capacity conforming to current Health Department Standards. The use is a permitted use in this Light Industrial Zone (LI), therefore the project meets current zoning. The project has been found to meet the standards of Article 12 of the Suffolk County Sanitary Code and has therefore been approved by the suffolk County Depart- ment of Health Services for construction. A permit for above ground toxic/hazardous liquid storage tank system and drum storage facilities has been issued, thus con- forming to all Department of Health requirements. There has not been any correspondence received from the New York State Department of Environmental Conservation in the allotted time. Therefore, it is assumed that there are no comments or objections from that agency. For Further Information: · Contact Person: Robert G. Kassner Address: Planning Board Telephone Number: (516) 765-1938 Thomas Jorling, DEC Albany Judith Terry, Town Clerk Suffolk County Department of Health Services Southold Town Building Dept. Applicant PLANNING BOARD MEMBERS Bennett Orlowski, Jr., Chairman George Ritchie Latham, Jr. Richard G. Ward Mark S. McDonald Kenneth L. Edwards Telephone (516) 765-1938 PLANNING BOARD OFFICE TOWN OFSOUTHOLD SCOTT L. HARRIS Supervisor Town Hall 53095 Main Road P.O. Box 1179 Southold, New York 11971 Fax (516) 765-1823 November 9, 1992 Gary D. Matz, P.E. Cashin Associates, P.C. 1200 Veterans Memorial Highway Hauppauge, NY 11788 RE: Request for site plan waiver Burt's Reliable, ~Inc. Youngs Avenue, Southold Zoning District: Light Industrial ILI) SCTM~ 1000-60-1-6 Dear Mr. Matz: On October 30th, The Planning Board received your letter and revised plans of October 6, 1992, incorporating the changes the Board had requested in its letter to you of July 2, 1992, (copy enclosed). The Board will grant the waiver in accordance with your letter and accompanying site plan which we received on October 30, 1992. If you have any questions, or require further information, please contact this office. cc: Victor Lessard, Very truly yours, Bennett Orlowski, Jr. Chairman Principal Building Inspector .1~., PLANNING BOARD MEMBERS Richard G, Ward, Chaimnan Mark S. McDonald ~ Ke~leth L. Edwards Telephone (516) 765 - 1938 PLANNING BOARD OFFICE TOWN OF SOUTHOLD SCOTT L. HARPJS Supe~s0r Town Hail, 53095 Main Road P. O. Box 1179 Southold. New York 11971 Fax (516) 765 - 1823 October 5, 1993 Gary D. Matz, P.C. Cashin Associates 1200 Veterans Memorial Highway Hauppauge, NY 11788 Re: Prosposed site plan for Burt's Reliable SCTM~ 1000-60-1-6 Dear Mr. Matz: The following resolution was adopted by the Southold Town Planning board at a meeting held on Monday, October 4, 1993: WHEREAS, Romanelli Realty, Inc. is the owner of the property known and designated as Burt's Reliable, Inc. SCTM~ 1000-60-1-6 located at 1515 Youngs Ave., Southold; and WHEREAS, a formal application for the approval of this site plan was submitted on July 21, 1993; and WHEREAS, the Southold Town Planning Board, pursuant to the State Environmental Quality Review Act, (Article 8), Part 617, declared .itself lead agency, and issued a Negative Declaration on September 14, 1993; and WHEREAS, this site plan was certified by Thomas Fisher, Building Inspector, on September 29, 1993; and WHEREAS, all the requirements of the Site Plan Regulations of the Town of Southold have been met; and now therefore, Page 2 Burt's Reliable October 5, 1993 BE IT RESOLVED that the Southold Town Planning Board approve and authorize the Chairman to endorse the final survey dated July 26, 1993, subject to a one year review from date of building permit. Enclosed please find a copy of the survey which was endorsed by the Chairman. Please contact this office if you have any further questions. Chairman enc~ cc: Thomas Fisher, Building Inspector Scott Russell, Board of Assessors Town Hall, 53095 Main Road P. O. Box 1179 Southold, New York 11971 Fax (516) 765-1823 Telephone (516) 765-1802 OFFICE OF THE BUILDING INSPECTOR TOWN OF SOUTHOLD January 3, 1996 Re: Building Permit #21699-Z Premises: 1515 Youngs Avenue, Southold Surf. Co. Tax Map #1000-60-1-6 During a review of our files it was noted that the above building permit has expired, and a Certificate of Occupancy has never been issued. According to the Code of the Town of Southold, Article XXVIII 100-284, it is unlawful to occupy or use a structure until a Certificate of Occupancy has been issued. Please contact this office as soon as possible so that we may clear up this matter. Thank you for your cooperation in this matter. Very truly yours, SOUTHOLD TOWN BUILDING DEPT. SUFFOLK COUNTY DEPT. Of HEALTH SERVICES -- APPliCATION -- PERMIT tO CONSTRUCT ABOVE/UNDERGROUND TOXIC/HAZARDOUS LIQUID STORAGE TANK SYSTEM AND DRUM STORAGE FACILITIES PROPOSED STORAGE SYSTEM IS: OFFICAL USE ONLY [] ABOVE GROUND TANK r'~ DRUM/BULK STORAGE DATE RCV'O REQU'O FEE []UNDERGROUNO TANK [] OTHER (SPECIFY- BURY' RELIABLE FACILITY NAME .............................- ADDRESS OF PROJECT 1515 Y0UNG'S AVENUF- (NO.) (STREET) SOUTHOLD NEW YORK 11971 (Cl TY ) (STATE) (ZIP) TAX MAP NA ~TION BLOCK LOT 1000 60 1 6 FACILITY OWNER BURT'S RELIABLE, INC. OWNER'S ADDRESS (NO.) (STREET) (CITY) (STATE) (ZiP) PHONE NI 765-3767 PERS. ON TO CONTACT FOR THIS PROdECT PAT ROMANELLI ADDRESS IF DIFFERENT FROM FACILITY OWNER 374 FULTON STREET (NO.) (STREET). FARi',iiNGDALE, NEW YORK 11735 (CITY) (STATE) (ZIP) PHONE Nt 454-1630 u BRIEFLY DESCRIBE PROJECT: Fuel 0il Depot with 4 tanks surrounded by a concrete containment area. Total capacity of the tanks is 95,000 gallons. I CERTIFY THAT ALL INFORMATION SUPPLIED HEREON AND ATTACHED HERETO IS TRUE TO ]~IE BEST OF MY KNOWLEDGE. OFFICAL USE ONLY THIS APPLICATION WITH ATTACHED PLAI~S ANOREPORT$ HAS BEEN REVIEWED AND APPROVED FOR CONSTRUCTION Town Hall, 53095 Main Road P. O. Box 1179 Southold, New York 11971 Fax (516) 765-1823 Telephone (516) 765-1802 OFFICE OF THE BUILDING INSPECTOR TOWN OF SOUTHOLD January 24, 1996 Romanelli Realty Inc. Box 544 E. Hoffman Avenue Lindenhurst, NY 11757 To Whom This May Concern: We are unable to complete your Certificate of Occupancy because of the following reasons: xx An application for Certificate of Occupancy is not on file. (Enclosed) xx No Underwriters Certificate on file. xx The check is not on file. $50.00 No Health Department Approval on file. No final inspection has been made. No Plumber solder Certificate on file. (All permits involving plumbing being issued after April 1, 1984). BUILDING PERMIT # 21699-Z Please contact our office on this matter. cooperation. Thank you for SOUTHOLD TOWN BUILDING DEPT. - CO CANNOT BE ISSUED UNTIL PLANNING BOARD APPROVAL GIVEN. FORM NO. 1 TOWN OF $OUTHOLD BUILDING D EPARTiVi ENT TOWN HALL SOUTHOLD, N.Y. 11971 TEL.: 765-1802 BOARD OF HEALTH ...J 3 SETS OF PLANS ......... SURVEY .................. CHECK ........ Date INSTRUCTIONS a. This application must be completely filled in by Wpewriter or in ink and submitted to the Building Inspector, with 3 sets of plans, accurate plot plan to scale. Fee according to schedule· b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this appli- cation .... c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issued a Building Permit to the applicant. Such permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose whatever until a Certificate of Occupancy shall have been granted by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. -- (Signature of applicant, or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder. Name-ofownerofpremises Romanelli l~ealey, Inc. (as on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer. (Name and title of corporate officer) Builder's License No .......................... Plumber's License No ......................... Electrician's License No .................... Other Trade's License No ...................... 1. Location of land on which proposed work will be done ............ ' .................................. 1515 Youngs Ave, oOuchola, bi. House Number Street Hamlet County Tax Map No. 1000 Section 50 Block ~ Lot. 6 Subdivision ................................ , .... Filed Map No ............... Lot ............... (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Fuel Oi 1 Depot b. Intended use and occupancy .... w o . ~apo~, ·; p.~-.l, . O~_.L .~.~ept}.C .............................. . ................ 3. Nature of work (check which applicable): New Building .......... Addition ....... ~t.. Alteration :...'..'... Repair .............. Re novai .............. Demolition .... : ......... Other Work .............. C'ONTASN'N~/NT AREA & RAIN oLELTER (Description) 4. Estimated Cost ................................ Fee ....... ~,1,275.00 (to be paid on filing,this application) 5. If dwelling, number of dwelligg units Number of dwelling umts on each floor ............... If garage number of cars 6. If business, commercial or mi:~ed occupancy, specify nature and extent of,each type of use .................... 7. Dimensions of existing structures if any. Front See Plan p~ Height ...... . ......... N tuber of Stories...O.n.q. ,~.f,.o.r.y. ........................... [[[[[. [[ ....... Dimensions of same structure with alterations or additions: Front ................. Rear ........... D.epth ................... i ' ' ' Height .....~ ......' ........... Number of Stories ....... 8. D,mensions of entire new construction. Front See PSan Rear . . ~ ~n'~ ........... Height ............... NUmber of Stories ....O.r.m. ~.to.r.¥ 9. Size oflot' Front 150' Rear 150' .............. ,T ' ',,' ..... }'5'~; ............. ......................................... ~eprn ............... 10. Date of Purchase ......... *. ................... Name of Former Owner ............................. 12. Does proposed construction viblate any zoning law, ordinance or regulation: ................................ 13. Will lot be regraded ...... {~/. g.h.[J;¥ ............. Will excess fill be removed from premises: X Yes No 14. . } omane] I ~ .R.?~!ie.y 37a Fu.lton st Ph~-e N~ 516-454-7 500 Name of Owner of premises ...... : ;' · .... Address ..................................... Name of Architect ......... .................. Address . .b:~ .r.m.i.n.g f p.l.e,, . ~.YPhone No ................ Name of Contractor Address Phone No ' 15. Is this property within 300 feet of a tidal wetland? *Yes ........ No .... ~ .... · If yes, Southol¢ Town Trustees Permit may be required. PLOT DIAGRAM Locate clearly and distinctly a I buildings, whether existing or proposed, and. indicate ~/1 set-back dimensions from properW Hnes. Give s~reet and bloci[ number or description according to deed, and show street names and indicate whether interior or corner lot. (Sea .Plans) STATE OF NEW YORK,~, ,o o coui~v o~-.' ~' q'-'O'-'"¢°' 'IC"~"t;~. c~ [°'~ .. . .~..O-&'~>:~x '~ .~<~.CO..C'~. Q~.tO,.~.~ k A k'. ..... being duly sworn, deposes and says that he is the applicant (Name of individual signing contract) above named. He is the (Contractor, agent, cor'porate officer, etc.) of said owner or owners, and is dul~ authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manne}' set forth in the application flied therewith. ' Sworn to before me this ............. FO ........ day ..... :. k..' .... '., 19 .?..5 Notary Pubhc, .(~..x'x..0~.~ ..... County ~ ~0.52-4t 26941 ........................... ~ ............... 0ta f~0 ,~, stmo( Couaty [ _ ~. (Signature ofapp,icant). :' ' ' C0mlmsmon [-x,3ires Jail. 31, 17c'[ C~ TD WITHSTAND TH£ FDLLDWIND FDAD$ ~ITHI~UT, THE ALLD~ABLE ~YR~SES 'AS SP~IF~ED' BY ' WiND LOAD :_ MECH/D ~, P~F'; . '- ' , Z S~RUCTURAL ~SPE:ZFIOA?IONS ~ DECKING- GALVANIZED ~TEEL- - BAKED £NAMEb 20 YR F~I~H ~ AND ERECTION DF. gTRUCTUR~L STEEL FOg BUILDINGS, ~9~O~.SMALL '~RRbY TD AEL '~ STRU:TURA~ S~EL,. ~DRK,~ . A~25 BOL~.WI~ BE DGH~N~D ~ ,,TH~ TODN A~A NED BY ~ FU~ E~O~ OF A ~AN' US NO AN ORDI~ SPUD WRK~OH. . :', BE DOH~NED ADDMON~Y BY .A,'NUT OR THIS OP~DON T~E~, S~ .BE ND ROTATION Oroddcts ¢0., Inc,i ;'Place ' ~ -F 'A' 'A' 3'X5' HANDHULE EXTERNAL DRAIN FOOTING DETAIL /x~ FINISHED GRADE / ~- CBN~UIT ¢9Y BTH£RS GRADE 60 e4 RE;DAR 16' O,C, EACH WAY FOOTING LAYOUT _k 5" DIA. HOLE FOR, CONDUIT BOLT PA"FrERN - "~"~ X 1,~"~ ANCHOR BOLTS: (4) ANCHOR BOLT Y~rk Sbb iduc~n Liw, DETAIL. FOOTING SPECIFICKTiONS: 1) ALI FOOTINGS MUST BE DESIGNED iN ACCORDANCE WITH LOCAL BUILDING CODES, 2) FOOTING SIZE BASED ON 2000 PSF MINIMUM SOIL BEARING CAPACITY. 5) TOP OF FOOTING ELEVATIONS SHALL BE EQUAL UNLESS STATED OTHERWISE. ') BELOW FROSTL!NE AS REQUIRED EXTEND, F~OTING ~ FOOTIi'~G, S,ZE OF ~ . WIDTH X,lliC~r.~LENGTH X ~,~'__ DEPTH IS REQUIRED ~t.~ t.~ MOHAV~ MTET. AL PRODUCTS CO. WILL ASSUME NO RESPONSIBILITY AS TO THE SUITABILITY OF THESE AND OTHER SPECIFtCATIONS TO MEET LOCAL BUll_DING CODES. MohaWk Mefal Producfs Co., 2175 Beechgrove Place Utica, NY 15501 315-795-5000 ~ JPF : ~, ~]!. , ~. ,,, ~ , , TIIU~K LOADiNe* CONI'AllilLrlflr CJLLCU"ukT1(DNS , ,. , , RE~D~ CAPACITY OF C~TAI~ENT (liB) - 3,850 GALS (515 CU.FT.) ~ ~~ur u.~.'~' '* ~'~ ' {(~' x 15') · (40' x 20') - (12~ x 5')) x O.S' DEEP ~. ~r~ ~ ~,~V]~ ~ -~- -., , AL~ ECES~RY, SAF~ PR~A~ONS,AS NXCL BE CA~TY OF LQ~ZNG PAD: 857 CU.FT. , ~ ~, ' ~Rt~,F~T~ ~ T~TACLAT~ OF TH( N~ CONSTRUCT~. T~AL ~ ' ; ~ ~,~ ~ ~E,,~R[~"S S~C2F~CAT~S ~D ~[CD~(~T~S. ~ ~*' CAPACZTY Or LOADZNG PAD AND SUMP P2 - 857 * 8 - 865 CU,FT. :Y ~' ~ '~ ~ T~OF '~ ,SERVICES ~O ALL RE~T~ C~CRETE * ~SIGN SP~LL CO~A]~ CAPACiTy - 865 * 525 - 1~ F, ~ :, ' '~~ ~' ~S ~ES~BLE FOR THE DES~GN'OF THE ~N SHELTER ~ , ~ 4. , ~' ~E, ~, ~"~ O~ ~E[D' THE DESIGN' ~NUF~TUR~ STEADS :~ ~ ,: ~ U~L.,:~J~.A2,,~.- 6~; A.P,L 62O AND CARRY ~[ APPROPRIATE LABEL, T~ C~A]~, CALCU~TZOB ' ~[ T~S S~LL :~ ,G~UNDED. CAPA~ZTY OF ~RGEST TANK:- 25,'~00 ~LS (3,342 CU.~. ) ~ ~; ~[E. ~O~E,T~L BE ~POSXTZONED ON A S~LES ~ApED TO FiT ~E p~QUIRED'~PACZ~ OF CONTAZNNENT (11~) -Z7,500 GALS (3,676 CU.FT,) :~:~' ~*.;T~,..:S~CES '~ST '~VE A HZN~H~ ~ HOUR FIRE ~TZNG. ~' ? ~D~E~,~r ~ ELECTRO.kY ISOLATED FR~ TA~ THROUGH ~[ USE OF , '~ ,'D1E~C~I~ ,i ~AL~ , , - , cAPACiTy OF CO~A~NHENT ~6" OF FREE~ ~. ~ ,, , , ~ , - (61' x 50' x LS') - (3.gSQ.FT. x 151 LZN,FT.) - 3,985 CU.FT. ~, ~ : CAPACX'TY OF S~P~ -'3' x 3' x 3' -~1 CU.FT. 'h ,~ '.., '- ,' ~ ~ : ~. :~] ,~:~,SL~.AMAy ~R~ CONTA~ENT ~EAS. ' ~P~C]TY OF C~TAZ~ENT ~D 5~P ~ - 3,985 + ~7 - 4,01~ CU.FT. , . ~ ~ '- '~* . .I DESIGN: ~P~LL'CONTA~N~ENT CAPACZ~ - 4,01~ * 3,676 - :-~ :, 8) '~iN,~MikC~ F.g~ NI~ G~TERS ~D LEADERS TO CARRY ~Z~T~R .,,: ~ 9:,':', ~PE~TZ~St~A~ ~l~ ~N THE ,CONTAZNHENT NALL?-~ALL PZPING eASSES , , 20-~* ~ ~[~ RESISTANT S~ANT HUST BE USED ~N ALL CONCAVE ~ TO ~ ' ,, (:~. ,~E ,NA~RS~P ~ '6REENST~ ~DEL ~7~] ~ EQUAL, THE SEAL~T ZS " ]1. ~E~ ~A 'Y'~ T '~ .,~O RE'ESTer. PETRO~H RESISTANT .COAT~G TO THE E~ZRE, ~ P ~ ~ V~" ~E OF~ C~TA]~ AR~S.~v~E PE~LE PG 2~]2-~ OR EQUAL ~ .~ .~'~ ~ " r,. ]Z. '~' ' A~' ~ ~ST BE ~]~RINED~ DRY AT ALL T~HES. NACCU~TEDA~ 0 CE i~8~ V~ ' - ' ' A~. ~'~ .~ ~0. ALL ~E~TER MUST 8E O]SCHARGEO ~ C ~ . I , 7 '. .' '.'~l~ A~DES'PE~';~R HAULED BY A LZCENSED HAULER. uTm~m V~ SITE LOCATION MAP ~ , ~ N.T.S. ~ ~ ~ R~ ~ 8~ ~ ~UIP~ ~T~ ~NM~ ~. ~SUPPORT PIER {typ.) ~ ~CREEN~PLANTING, 15 ~ITE PI~S~ P/nus ~obu~, lot O,C, ~ ~ / f ~SHEETSEE DETAIL, ,", I ~,.,,.." .............. . ~ ~...~ ~ . ~s7~6., ~' s?~A~. -- F~,C~ i,oo.~; , ~¢~'O0"E. ..-- _ 4" ~= .~ ~ -.~ .... , .~ ~ x ~'~ ~ ~~ ~, ~' "1 ~ 7'PARK[~PX~] ~ ~' OFkCE 8UlLDINO '~ 5 PA SPACE*,, r BC EXIDiN6 GARAGE ~ ~ 95.~ OONCR~TE TRUCK SPILL CONtAINmENT , CONC, SUPPORTS._ ~~ ~ ,96.4 ~ ~ m . ~ TIMBER :' - ' F~ PiPE ~ CONC APRON I '~ ~ · · · ~: * / LOADING PANEL~ : ~ ~--_ ~ = ~ ~TW9~2 ' i':" PUMPS . ~ - SPOT I ~- ~ ' "' '"' ~, ~ING 95,1 ~ I I G~S ~ ~ ; ~ SUMPS2 14' 12' I'~ aR~V~L AA? SH~L ~ , . I -%~H- I -- ~ ~ 50 OVERHANG / ~ ~ , · RIM - ' ~ , ~ ~ ~ ..TRUCK CONTAINM~T -~ BRADFORO PEAR~ ~ z ~ ~ ~ . ~ PS / A~ ~ ~ ~ ~ SEE ~A~L 0 ~2 PUM 95~L, 0~ ~. , ,/;~~ ? '~ ,2' HIGH CONCRETE ~ ~ ~ = ~.~ ~ o ~ 0 ~' I ' ~ 95.7 952 I I/~, CONTAIN~NT W~L z z z . ~ o I I ] SEE D~AIL, SHEET~2 ~ ~ ~m z m ~ ~ ~0.~0'0 ~ T~OFSLOPE 945 ~0 9 0 0 ' ~ ,5~EP,e~/~ ~ ' /[- I~, 3,I_~ o -- ~ ~ o o ~ ~ -;~~' / 0.s~ ~ ~o.s' ,0.¢ ~0.5' _~'. _ [0.¢ _ D ~ ~' / / ~ ~ CONCRETE SECONDARY CONTAINMENT I s.?~o26'oo"w. ,ONG ISLAND RAILROAD /' '~ ~ , SITE PLANo . ~ ~ PARTIAL SITE PLAN J LAND OWNER~: ROMANELLI REALTYm ~ ~ ~" '' · SURVEY INFORMATION BY YOUNG& YOUNG 574 FULTON STRUT , F~R~U~AC~, N.Y, U?~ JUL 2 8 1993 ASSOCIATES P C' _ . ..... CASHIN ' : T ¢','KbLIA' I:INU, "'.,:,,, SITE PLAN ,~0, ,,DA~ , DES~IP30N , , , , , ~ .,~,~ ,.. ~ OC~ 1992 ENGINEERS ARCHITECTSPLANNERS'' ' ' ' ' I'':1~~ C ~1; *¢ " 515 YOUNGS AVENUE HAUPPAUGEI ~:,,, w. HANSONLOCATION MAP 1200 ~RANS MEMORIAL HIGHWAY, , NEW YORK .. ~ : . t~ '" ' ' ' '~ ~ ' ; '' '" LD RK ] i971 ?' ~' "~ ,~ ~ ~"~"~"~ "~ * 255 EXECU~VE DRIVE 1200 VETERANS MEMORIAL HIGHWAYROU~ 22;r ,, ~,-- ,.r ,., , ,[~.[, ,.~,~, .,, ' , , ~ , ~,~ , .... ~'~ ~ sOA~ SCTM~ 1000-60-I-6 PLAINVIEW HAUPPAUGE BRE~R ' rI i II ' I , . : C;? , , ; , , ~ ~S S~ , ~T, or~ NEW YORk 11803 NEW YORK 11788 I m NEWYO ~ 'k ' 'i ,j - ' mi 'i I' mi ~ i "m I m ~r~iimmi~:'~*](;m' fiE: ' m m '" TRANSLUCENT CORRIGATED PLASTIC ROOFING GRAOE AWAY FROM CONTAINMENT AREA 10'-6" I0'- 6" PIPES OVER (~SECTION A SCALE: I"= 5' ~-0' 5'-0" 40'-0" a. 5'-0" 5'-0" : ~,~, MANHOLE % I I ' ~" WALL ~ ~ I SUMP ~ ~.......L,. ,_: ...... J ,"k. ,~,B . SECTION B SCALE: I"=§' S COATS I~1- 2112 - 2 EPOXY I I CONGRETE SUPPORT PIER GUPPORT COLUMN GRADE AWAY FROM CONTAINMENT AREA __ RAINSHELTER I --TRUBGFRAME~ I BY CORONIB I I BUILDING SYSTEMS D _1 L 1 CORRIGATED PLASTIC ROOFING RAIN CUTTER _o ~.~.. I ....... ':,. ,.. ; ........ '. ,' ~ * ,': : ~.,;. ~. .~ ..... · - ' ' ' * I I I "~' I GRADE AWAY FROM I I ' I I CO.~A,NMENT ARE~ ~J L, SUMP#, CO.CRETE rJ L. O RETS RAIN SUTT£R (~SECTION C ~CALE: I"= §' HEAVY DUTY MANHOLE FRAME AS / AND GRATE AS MANUFACTURED ~,.2~RAR ANCRORS- E PE.~ S,DE ~ CONC..SLJ i WITH 6x6./~N4.014.0 5-~4 EBAR (CONI~) ~ -1 WAL 8 SLAB JOINT DETAIL CONTAIN~MENT ~WALL DETAIL SCALE,,~'=,'-O" I ' ~CA'~:,",,'-O" C CONCRETE CURB DETAIL 11/2" I' 0j' SCALE: = - CONCRETE PIER FOR RAIN SHELTER N.TiS, SUMP #2 IREVISIONS ' I CU£Nt '}' ',.' ,' :, , : , I .~-~ .~'~,I ....... I I ~o4.-t I ICASHIN LANNERSI I ' ! B'u T s REUAB E, NC., ,sc.c osss cT,ONS I ENG NEERS - A , , , - ~__,r ' ,~ ; ', : :]' . , ' ~ AND DETAILS VETERANS MEMORAL HIGHWAYROUTE ~ ' SO'UTHOLD; ,NEW ;YU~K "11911 : ' ,.' ~ J ~E'~' YbE~ ~o~ NEW ~O~K ~788 i NEW YOR~ ~OSO~ : . ,.. :,. '"-~" '~ ~'"' '~'"'~'~"'-'' "' .... ~ ?'~":'~'~"~'~ ""~'~'"'"t ...... ..... '=' :-""-~h~-.,,' ~"'" , -- 5B-DETI ' ; ' , 2. ~INFffiClffi' ~EL ~ ~F~ '~. ~ A-615. ~ 60 ~L. EX~ ~ ~:, ,,, , , LSGOOABNCL / MANHOLE  I' OVERFILL LEVEL SWITCH ~ ~ ~ .~FXLL ~]~ AT ~E T~ ~L ~S~[~ TYPICAL HIGH LEVEL ALARM LOCATION ~' P~EL. s~ BE ~Z'PP~ ~ ~Z~ ~ VZS~ ~Z~. ~. 7. ~ ~ P~L ffi ~~~ S~ ~ L~ ~E~ ZT ~ZLL'BE ~EN ~Z~ ~ BY ~ ~ F~LLZ~ ~ T~. , 9. ~E SO~ID V~VES AT ~E T~ S~L BE ~LLY CLUED ~ BE WIREDmTO ,: ~ T~[NG P~E. ~ ~ D~O~S A NORMA~Y CL08~ ~O~OID V~VE ~T A~O~TIC~Y OP~S ~1~ ~E PUMP IS IN OP~TION. DISPENSER6 7 DISPENSER 11 DISPENSER t5 DISPENSER FI~ FILL RLL FRAME AND GRATE m BE i 1 2 5 t 2 5 4 5 6 T 8 9 10 lml 12'15 14 15 m6 IT - ~ GRADE FILL TANK ~2 OFF C O' C 0 C C C ........... ~' FILL TANK ~3 ~ OFF ........ C 0 C ,C - m - -- 0 .,~ ~ FILL TANK ~4 OFF ........... C 0 C C -- 0 ~ ~ ~ ~ L"''M~N' EMPTY TANK ~ ON 0 C 0 C 0 '~' ~/~ ~ _ EMPTY TANK ~2 O~ C 0 0 C 0 ~ .......... ~ ; EMPTY TANK~3 ~ ON ..... 0 C 0 '0 .... 0 ' ' '~ VALVE OPERATION SCHEDULE ~ ~'~ PIPING SCHEMATIC LEACHING BASIN DETAIL REVISIONS CLIENT ENGINEERS- ARCHITECTS- PLANNER'. BURT'S RELIABLE, ~ .,,~,~ AND 1200 ~RANS MEMORIAL HIGHWAY, HAUPPAUGE, NEW Y~K 1515 YOUNGS AVENUE ~ ,~ ,:, W. HANSOk ALARM SPECS , SOUTHOLD, NEW YORK 11971 ~<:o~,? ,~ ~.~c~.~ 255 EXECUTIVE DRIVE 1200 VETERANS MEMORIAL HIGHWAY ROUTE 22 . ~ 6. MATZ PLA~NVlEW HAUPPAUGE BREWS~R SCALE -, - AS SHOWN SHEET ~ OF qEW YORK 11803 NEW YORK 11788 ~ YORK 10,509 h ~ I I PUMP VALVE FILL TANK #t OFF 0 C i C 0 C C C .......... FILL TANK #2 OFF C O' C 0 C C C ........... FILL TANK #3 -- OFF ........ C 0 C ,C .... 0 FILL TANK #4 OFF ........... C 0 C C m 0 EMPTY TANK #1 ON 0 C 0 C 0 EMPTY TANK #2 ON C 0 0 C 0 ~ .......... EMPTY TANK#;5 -- ON ..... 0 C 0 ,0 .... 0 EMPTY TANK #4 ON ........... 0 C 0 0 -- 0