Loading...
HomeMy WebLinkAbout48767-Z ��O��SUFFOI oy Town of Southold 6/17/2023 o P.O.Box 1179 o - 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44175 Date: 6/17/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 50 CR 48,Peconic Peconic SCTM#: 473889 Sec/Block/Lot: 69.-4-13 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/13/2022 pursuant to which Building Permit No. 48767 dated 1/20/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Szczotka,Nancy of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48767 7/12/2023 PLUMBERS CERTIFICATION DATED Aut oriz d Signatur TOWN OF SOUTHOLD oo�sufFnt,r� a BUILDING DEPARTMENT Gyp ' TOWN CLERK'S OFFICE oy • �� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT-MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48767 Date: 1/20/2023 Permission is hereby granted to: Szczotka, Nancy PO BOX 294 Peconic, NY 11958 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 50 CR 48, Peconic SCTM # 473889 Sec/Block/Lot# 69.-4-13 Pursuant to application dated 12/13/2022 and approved by the Building Inspector. To expire on 7/21/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Bui ding Inspector SO!/jyQlo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlina-town.southold.ny.us Southold,NY 11971-0959 Q �yC0UNT1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Nancy Szcotka Address: 50 CR 48 city:Peconic st: NY zip: 11958 Building Permit#: 48767 Section: 69 Block: 4 Lot: 13 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: EmPower Solar License No: 65990ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 10.79kW Roof Mounted PV Solar Energy System w/ (26) SPR 415W Modules, SunPower Monitor, Combiner Panel 70A OCP Notes: Solar Inspector Signature: Date: June 12, 2023 S. Devlin-Cert Electrical Compliance Form OE SOUT,yOIo l L/��� � C✓`ry C # # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631.765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] ,FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: -471n A O/K T-44 � c � DATE INSPECTOR �7�7 OF SO(/lyO� * * TOWN OF SOUTHOLD BUILDING DEPT. c-um, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL gbla)e--- FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: o O/2 DATE �'/�" '73 INSPECTOR t, .:+ '`�+ , } ;� � � �, � �t�. ,,�,L ✓ .. t _ �r �� .i��-_ i. x ,� `��ft .'i. � � rs;. .�, n�, ,�tg gr' �F _ � t s.l Lp iy., N �-, i� I��r��� ' T q i i Y �,� ,� {'�f.' ��'t t :�,;�.> �L •' ,. � ,��,,� _ - . f �a .xS`". �/�� XLD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) a ----------------------------------- -- FOUNDATION (2ND) f ^� v l® O ROUGH FRAMING & PLUMBING - r r INSULATION PER N. Y. STATE ENERGY CODE — 6 /lam aSoz� GauN O� 2 C O FINAL ADDITIONAL COMMENTS N t, - - --- X o\ASUFFatK�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y- Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 hgps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only �n. PERMIT NO.' Building Inspector: ® V _ . DEC 13 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the,owner;an ®UONG O � Owner's,Authorization form(Page 2)shall be completed. 1bVIH�tOF60Ui}(OLD Date:12/1/22 OWNER(S)OF,PRO.PERTY ' Name: Nancy Szczotka SCTIVI#1000-069.00-04.00-013.000 Project Address: 50 County Rd 48, Peconic, NY 11958 Phone# Email: Iittlezotta55@gmail.ccom Mailing Address: 50 County Rd 48, Peconic, NY.11958 CONTACT PERSON: Name: Ines Fernandez (EmPower CES, LLC.) Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email permitting@empower-solar.com DESIGN PROFESSIONAL.IIVFORMATION: Name: Gregory D: Sachs Mailing Address: -4589_Adstin Blyd.,.lsland Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@emp.ower-solar.com .CONTRACTOR INFORMATION: Name: EmPower CES, LLC. Mailing Address:. 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592' Email: permitting@empower-solar.com DESCRIPTION.OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: EXOther Roof mounted solar panels $42,363.19 Will the lot be re-graded? ❑Yes CXNo Will excess fill be removed from premises? ❑Yes KNo 1 r PROPERTY INFORMATION Existing use of property: Residential-1_.F_amil.y Intended use of property: Residential 1 Family Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes X No IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code..APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print e): Ines Fernandez IC4Authorized Agent El Owner Signature of Applicant: Date: 12 `Z Ryan M.Moser STATE OF NEW YORK) NOTARY PUBLIC,STATE OF NEW YORK SS: Registration No.01 M06412506 Qualfied In Nassau County COUNTY OF ) Commisslon Expires December 28,2024 Ines Fernandez being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of ,20_j)Q Notary Publ' PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, Nancy Szczotka residing at 50 County Rd 48, Peconic, NY 11958 do hereby authorize Ines Fernandez to apply on my behalf to th4Twn o - hold Building Department for approval as described h rein. 2Owner' a Date Van C_Q '�--?_C7LO�Ka Print Ow er's Name 2 ftp f BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0.959 Telephone(631) 765-1802 - FAX (631) 765-9562 rogerr(a.southoldtownny.gov seand(cr�southoldtownny:gov- �y� r C APPLICATION FOR ELECTRICAL INSPECTI:ON.- ELECTRICIAN INFORMATION (All Information Required) Date-, 12/1/22 F Company Name: _ EmP__ower CES,-.LLC. .Name: Timothy_Crotty _ License No.: ME-65990 email: _ermittin em ower-solar.com i Address:_ 4589 Austin_Blvd.,_Island._Park,_NY.11558� Phone No.: (516)-544-4592 . JOB SITE INFORMATION (All Information Required) --- - `' Name: . Nanc Address:__50 Count Rd-48-Peconic NY-1 1958 Cross Street: i Phone No.:---(516) 375-6954 BIdg.Perrnit#: email: littlezotta55C@-.qmaii.com I' _ Tax Mar)District: . 1000 Sgctiori!069.QO Block: 04,00-- .Lot:0.13,000.: BRIEF DESCRIPTION OF WORK(Please Print Clearly) Installation_of roof mounted solar panels (26)SPR-415w ACPV modules_10.79kW total_system-size Circle All That Apply; Is job ready for inspection?: YES / (9' Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size:'-.. _ -A #Meters . _ .__ Old Meter#.. _ New Service- Fire Reconnect-Flood Reconnect-Service Reconnected-Underground -Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y. N Additional Information;; PAYMENT.DUE.-WITHHAPPLICATION .r i Request for Inspection FormAs 4 i lk Bunch, Connie From: John Korinis <cbjohnk1 @gmail.com> Sent: Thursday,June 1, 2023 11:58 AM To: Bunch, Connie Subject: 50 County Route 48 Attachments: 20230601_114621 jpg; 20 0601_114436 jpg Can you please tell the inspector th t we decided disconnect the outlet altogether. Thank You. Solar Inspection Nancy Szczotka la ns+cd I n 50 County Route 48 Peconic, NY 11958 570-878-9478 ATTENTION:This a it came from an external source. D not open attachments or click on links from unknown senders or unexpected a ils. i 1 NY S 1 F PO Box 66699,Albany,NY 12206 New York State insurance Fund nySif.Com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE A A A A A A 522407627 AMWINS BROKERAGE OF NEW YORK , 200 ELWOOD DAVIS ROAD SUITE 200 LIVERPOOL NY 13088 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER EMPOWER CES LLC TOWN OF SOUTHOLD 4589 AUSTIN BLVD 54375 ROUTE 25 ISLAND PARK NY 11558 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2546 624-4 563452 05/01%2022 TO 05/01/2023 04/12/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2546 624-4, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH.RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVALASP.THE'NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN. THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY AFFORDS COVERAGE TO THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OFA LIMITED LIABILITY COMPANY. DAVID SCHIEREN GREG SACHS EMPOWER CES LLC THIS CERTIFICATE IS ISSUED AS,A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR, INSURANCE COVERAGE UPON,THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AMEND;EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 263370983 Mir" Focm WC-MT-NOPP1NT Vemi=3,(09d92019)[WC PoUwa546QM3 U-263 163 [aooa00000nmm7[aool oouoas�6sxa][ zI[ s�1[�eurlIo1-0oo017 EMPOCES-01 ABELLO CERTIFICATE OF LIABILITY INSURANCE DAT5i612022 MMIDDIYYYY) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0757776 CONT HUB International Insurance Services Inc. HONtJ,Ext):(310 568-5900 FAx 600 Corporate Pointe ) (FAX,No):(310)568-9098 Suite 600 ADDRESS• Culver City,CA 90230 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Southwest Marine&General Insurance Company 12294 INSURED INSURER B:James River Insurance C6rnpany 12203 EmPower CES LLC INSURER C: 4589 Austin Boulevard INSURER D: Island Park,NY 11558 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS - CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY'EFF POLICY EXP LIMITS L SD WVD ID MM/DD A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE OCCUR X PK202200006109 5/4/2022 5!4/2023 DAMAGES( RENTED 500000 EM E Ea occurrence) $ MED EXP(Any oneperson) $ 5,000 PERSONAL&ADV INJURY $ 1'000'000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 RPOLICY®JECT LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COacccidentSINGLE LIMIT $ ANY AUTO BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY Per accident $ AUTOS ONLY NONAUTS ONLY PROPERTY AMAGE Per accident $ $ B UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 5'000'000 X EXCESS LIAB CLAIMS-MADE 001306870 5/4/2022 5/4/2023 AGGREGATE $ 5'000'000 DED I I RETENTION$ $ WORKERS COMPENSATION SER LITE OTRH- AND EMPLOYERS'LIABILITY Y/N OFFICER ME BER ECCLUDED�ECUTIVE ❑ N/A E.L.EACH ACCIDENT $ (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) The certificate holder is listed as additional insured per attached endorsement#GL0202 0218. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Town ACCORDANCE WITH THE POLICY PROVISIONS. Route Southold Southold,NY 11971 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD YORK WorkersCERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that Carrie 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured EMPOWER CES LLC DBA EMPOWER SOLAR 310-534-7994 4589 AUSTIN BOULEVARD ISLAND PARK,NY 11558 1 c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 522407627 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"I a" Southold, NY 11971 DBL252634 3c.Policy.effective period 05/10/2021 to 05/09/2023 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described aove. Date Signed 5/9/2022. By. wid (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers' Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 413,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers' Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. oB-120.1 (12-21) IIIIIIIP11111° °20°��1�����(�12-2°1)�'lllllll I I Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name I GREGORY SACHS Business Name s certifies that the EMPOWER CES LLC DBA irer Is duly licensed he County of suNolk License Number:H-50211 i Rosalie Drago Issued: 05/30/2012 Commissioner' Expires: 5/1/2024 I ' i r Suffolk County Dept.of Labor,Licensing&Consumer Affairs MASTER ELECTRICAL LICENSE Name TIMOTHY M GROTTY Business Name This certifies that the Empower CES LLC DBA Dearer is"duly licensed .)y the County of suffoik ' License Number:ME-65990 RosalieDrago Issued: 1111212021 Commissioner Expires: 11/0112023 1 2 3 4 6 8 T B 8 10 11 12 13 EMPOWER I UTILITY TO I SOLAR UTILITY 4589 AUSTIN BLVD METER GRID ISLAND PARK,NY 11669 o BRANCH C BRANCH B BRANCH A TEL:516.837.3459 (8)SPR416W MODULES (8)SPR415W MODULES (9)SPR-01 SW MODULES FAX:516-706-1789 TOTAL DC STC POWER 3.32 kW TOTAL DC STC POWER:3.74 kW TOTAL DC STC POWER:3.74 kW L N AC4 www.om Dower-s ol6 r.com (el ENPHASE 1Q7HS MICRO INV (9)ENPHASE 107HS MICRO INV (9)ENPHASE IQ7HS MICRO WV TOTAL AC POWER 3.072 kW TOTAL AC POWER 3.46 kW TOTAL AC POWER:3A8 kW G H CONTINUEAS CONTINUE AS CONTINUEAS H TrovDUPowEnaaLRic�DiRuurlioRREO REPRODUCTION OR DISTRIBUTION Of THIS REQUIRED FOR INV.._ REQUIRED FOR INV. REQUIRED FOR INV.�. N�TERIAL 18 STRICTLY PRDHISRED WITHOUT SPECIFIED STRINGING SPECIFIED STRINGING SPECIFIED STRINGING ••\ PRIOR ePECIFIC WRITTEN PERY18810N PROFESSIONAL BEAL �_ACII—ACIILACI -AC DISCONNECT (1)SPR415W MODULE (1)SPR415W MODULE (1)SPR416W MODULE TO L1 L2 N G 60A,2P CB G (1)ENPHASEMICROINV.INV.2 (1)ENPHASE MICRO INV.INV.2 (1)ENPHASE MICRO INV.INV.2 HOUSE G LOADS AC1I—Ac, AC1 (1)SPR-415W MODULE (i)SPR-015W MODULE (1)SPR416W MODULE (1)ENPHASE MICRO INV.INV. (1)ENPHASE M.ROINV.INV.t (I)ENPHASE MICRO INV.INV.1 AC4 F MAIN SERVICE PANEL F Act Act Act 1-PHASE 120/240V SUNPOWER DATA E MONITORING tA, E L1 N GP CB P CB TO RACKING G Ac D GROUND NEMA 3R A 2P CB D REV: DEscaPrroN DATE: LABEL DESCRIPTION LABEL DESCRIPTION ENCLOSURE PROJECT NAME: (1)#6 AWG,EGC OA,2P CB ACI SPR AC CABLE AC2 I.IW PVC S—aft,Nancy RESIDENCE (2)#12 AWG (8)#10 AWG (1)#10 AWG,EGC A PROJECT LOCATION: C AC3 314•PVC AC4 1•PVC C (3)#10 AWG (3)#6 AWG 60 COUNTY RD 40,pECONIC,NY 11969 (1)#10 AWG,EGC (1)#B AWG,GEC PROJECTS: PROJ.PHASE PERMIT DATE: 05/311!023 B B DESIGNED BY: FK CHECKED BY: XX AC COMBINING MLO PANEL SCALE NTs 1-PHASE 120/240V TITLE: NOTES: THREE LINE ELECTRICAL SCHEMATIC 1.NEUTRAL 8 GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR ELECTRIC SYSTEM) 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN SERVICE PANEL USING IRREVERSIBLE SPLICE TOTAL SYSTEM SIZE:10.79 kW A 3.USE TAP RULES FOR SONG TAP CONDUCTORS(NEC 24021) 26 SPR-415W MODULES A SHEET: 4.SIZE GEC AND EGC AS PER NEC 240.66,NEC240.122 RESPECTIVELY ( ) 5.USEMC ONLY IF INCLUDED GEC 15 ADEQUATELY SIZED. (26)ENPHASE 107HS MICRO-INV. SE-03 •1 2 3 4 5 6 7 8 9 10 I1 1 12 1 13 y Gregory Sachs, PE 4589 Austin Blvd, ' (516)-544-4115 Island Park, NY 11558 permitting@empower-solar.com December 2, 2022 To Whom It May Concern: The purpose of this letter is to certify that the existing roof structure located at: 50 COUNTY ROAD PECONIC, NY 11958 can support the additional load of the solar energy system, in addition to wind,snow and gravity. Portions of roof structure covered and not covered with photovoltaic panels are in compliance with R324.4.1.1. Furthermore, it has been determined that the structure complies with the 2020 Residential Code of New York State including the ASCE 7. Please see Table 1 below for specific data relating to the calculations for each roof structure involved in the solar energy system installation. . Table 1 . Rafter Snow Wind Max Span Layers of Roof Surface (ft) spacing Cross Section Load Speed Kneewall Collar Ties Shingles (in) (psf) (mph) South-West 1 29.58 16 Nominal 2x12 20 135 No No 1 ISouth-Eastll 53.00 1 16 Nominal 2x12 1 20 135 No I No 1 1 COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES Sincerely, AS REQUIRED AND CONDITIONS OF Gregory Sachs, PE PR VED AS NOTEDeDATAAP -� B.P.# .!.� v; NINa.BOARD 61�TRUSTEES FEE: BY: NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED OCCUPANCY OR . FOR POURED CONCRETE �+ J f JAE W y- 2. ROUGH - FRAMING & PLUMBING USE��IS o `l1NLAWFFUL. D s .� 3. INSULATION WITHOUTCE;RTIFICAT " �9C, 4..FINAL - CONSTRUCTION MUST �� tiN c� BE COMPLETE FOR C.O. O _00C :RANGY t.►, w ALL CONSTRUCTION SHALL MEET THE (D z REQUIREMENTS OF THE CODES OF NEW C� YORK STATE, NOT RESPONSIBLE FOR ELECTRICAL DESIGN OR CONSTRUCTION ERRORS. 411RE® pRoF�ss��� INSPECTION REQ 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWEP SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 o TEL:516-837-3459 RESIDENTIAL we 516-706-17$9 www empower-soiar.com ,i SOLAR PROJECT THE INFORMATION DISCLOSED HEREIN IS THE SOLE H PROPERTYOF EMPOWER CES.LLC.UNAUTHORIZED REPRODUCTION OR DISTRIBUTION OF THIS PROJECT TEAM. MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL OWNER: Nancy Szczotka G G 1' D. PHONE: (516)375-6954 lV: F SOLAR INSTALLER: GREGORY SACHS,PEENGINEER OFD c`r� N UJ W - � Z EMPOWER SOLAR r, 4589 AUSTIN BLVD 4589 AUSTIN BLVD ISLAND PARK,NY 11558 2S Q 4 531 ISLAND PARK,NY 11558 F� Q PHONE:516-837-3459 AROFESS\0� E PHONE:516-837-3459 __ _ _ E r e�.-a r__�---���—i//__.__�.�_—p,. �"l,�Uired 5Et6•NY.SWbh Cn• D R J�Q° fj' l' i p REV: DESCRIPTION: DATE: PROJECT LOCATION DATA: SHEET INDEX: PROJECTNAME: ADDRESS:50 CountV Rd 48,Peconic, ST-01 COVER SHEET Nancy Szczotka S-01 EQUIPMENT LOCATIONS NY 11958 S-02 STRUCTURAL PROJECT LOCATION: i 50 County Rd,48,Peconic, C T� SE-01 ELECTRICAL c am iff 2 soC—tyR-d48, j NY 11958 �, f-•{ l Southolq NY 11977 y I %' �•� ` SCTM:069.00-04.00-013.000 PROJECT#: ' e o`o I PROJ.PHASE: PERMIT DATE: ,B I �J t �. 'P 8 DESIGNED BY: ED CHECKED BY: GS SCALE NTS MAP TITLE: COVERSHEET A SHEET: ST-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 A' 2 3 4 5 6 7 8 9 10 11 12 13 v ..ro....nay....aa,o„�. COUNTY ROAD 48 1 4589 AUSTIN BLVD ISLAND PARK,NY 11558 O TEL:516-837-3459 FAX:516-706-1789 D-vEQUIPMENT LEGEND: SETBACK LEGEND www.empower-so Iar.c o m 2 H El MODULES ® H TPHRoaERTM INFORMATION DISCLOSED ucurNiAluniop¢°E�o 36"CLEAR PATH REPRODUCTION OR DISTRIBUTION IT THIS MATERIAL IS STRICTLY PROHIBITER WITHOUT 5 PRIOR SPECIFIC WRITTEN PERMISSION UTILITY METER ® 18"RIDGE SETBACK PROFESSIONAL SEAL 4 G INVERTERS ® ACCESS ROOF G �A 4❑ SOLAR DISCONNECT S� 1 QjMAIN SERVICE PANEL \` rSQUTHWESTA-ROOF: I F 3 ", 9 SUNPOWER-416W--ACPV PANELS ( TOTAL POWER:3.735 kW W ORIENTATION:228%PITCH:28° _ Q,/ TYPE 1:FLASHLOC DUO6 �is 3 QF�3 Qv -` Ct SOLAR ACCESS:95% ` J TSRF:87% E �/�, k � E V` D I — SOUTHEAST-1 ROOF: p REV: DESCRIPTION: DATE: - 3 17 SUNPOWER 4,15W-ACPV PANELS PROJECT NAME: TOTAL POWER:7.055 kW ORIENTATION:138°;PITCH:27° SZCZOTKA RESIDENCE TYPE 1:FLASHLOC DUO SOLAR ACCESS:84% PROJECT LOCATION: TSRF:80% Q 50 COUNTY ROAD PECONIC,NY 11958 PROJECTIk. PROJ.PHASE: PERMIT DATE: 08/01/2022 B B DESIGNED BY: ED CHECKED BY: GS SCALE NTS TITLE: EQUIPMENT LOCATIONS ROOF LAYOUT A A NOT TO SCALE SHEET: S-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER SOLAR VD SUNPOWER MODULES AND PARK,AUSTINY 115 ISLAND PARK,NY 11558 ON INVISIMOUNT RACKING TEL:516-837-3459 FAX:516-706-1789 SHINGLES www.empower-so I ar.com THE INFORMATION DISCLOSED HEREIN IS THE SOLE H RAFTERS H PROPER UN OR DISTRIBUTION E REPRO CTIO OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL G G i C w 111 F TYPICAL ROOF SECTION U—rZ NOT TO SCALE SUNPOWER PANEL SPECS tiG P'4 s O�Q E MODULE POWER(WdC) QTY MODEL# LENGTH I WIDTH I DEPTH WEIGHT TABLE S-1.1:MAX.ATTACHMENT SPACING E PROFESS SPR-415 26 SPR-A-SERIES-AC 72.2" 1 40.0" 1.57" 46.5 LB PORTRAIT: 5'-4" LANDSCAPE: 8'-0" SPR-E/X-SERIES-AC 61.4" 41.2" 1.81" 42.9 LB D D REV: DESCRIPTION: DATE: NOTES: PROJECT NAME: 1. TOTAL SYSTEM DC POWER:10.79 kW 2.RACKING SYSTEM INSTALLED IN ACCORDANCE WITH CODE-COMPLIANT INSTALLATION Nancy Szczotka MANUAL 3.ATTACHMENTS TO BE SECURED TO ROOF ASSEMBLY USING 5 mm STAINLESS STEEL SCREWS PROJECT LOCATION: C AND/OR 5/16"STAINLESS STEEL LAG BOLTS SPACED ACCORDING TO TABLE S-1.1 C 50 County Rd 48,Peconic, 4. ALL ATTACHMENTS TO ROOF, MOUNTING BRACKETS & HARDWARE MEET OR EXCEED NYS NY 11958 CODE REQUIREMENTS 5.INSTALLATION TYPICALLY MAINTAINS 7/8 INCH SPACING BETWEEN MODULES 6.SIZES OF STRUCTURAL MEMBERS THAT WERE NOT ACCESSIBLE FOR DIRECT MEASUREMENT PROJECT#. ARE BASED ON OBSERVATIONS OF ACCESSIBLE MEMBERS, CONSTRUCTION DEPTH OR PROJ.PHASE: PERMIT BOTH IN ADDITION TO KNOWLEDGE OF STANDARD CONSTRUCTION PRACTICES AT THE DATE' B TIME OF CONSTRUCTION B DESIGNED BY: ED 7. THIS DOCUMENT CERTIFIES THAT THE ROOF STRUCTURE HAS BEEN CHECKED FOR WIND, CHECKEDBY: GS SNOW, UNBALANCED SNOW, LIVE AND DEAD LOADS BASED ON ASCE 7-10 CHAPTER 30- SCALE: NTS WIND LOADS- COMPONENTS AND CLADDING (C&C)AND FOR CONFORMANCE WITH THE TITLE: 2020 RESIDENTIAL CODE OF NEW YORK STATE.THIS CERTIFICATION DOES NOT APPLY TO STRUCTURAL ANY ADDITIONAL ROOF ALTERATIONS AFTER THE DESCRIBED INSTALLATION A 8.THIS ROOF STRUCTURE AS SHOWN IS ADEQUATE TO SUPPORT THE PROPOSED LOADS A SHEET: 9.REFER TO STRUCTURAL LETTER FOR SITE SPECIFIC AND ROOF SURFACE DATA S-02 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER NOTES: , SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR TEL:516-837-3459 ELECTRIC SYSTEM) FAX:516-706-1789 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN www.empower-solar.com STANDARD INVERTER ASSEMBLY: SERVICE PANEL USING'SPLIT-BOLT CONNECTOR' THE IN FORMATION IS THE SOLE H 3.IN SOME CASES POWER FOR DATA MONITORING ENCLOSURE MAYBE H PROPERTY OF EM DISCLOSED CES,LLC UINAUTHOR¢ED REPRODUCTION OR DISTRIBUTION OF THIS DERIVED FROM MAIN SERVICE PANEL MATERIAL IS STRICT LY PROHIBITED WITHOUT 4.CONNECT UTILITY SIDE TO PANEL LUGS PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL 5.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 6.SIZE GEC AND EGC AS PER NEC 250.66,NEC 250.122 RESPECTIVELY 7.PROTECT GEC AND EGC SUBJECT TO PHYSICAL DAMAGE AS PER NEC G SOAR 250.64(B),NEC 250.120(C) G ARRAY 1 8.FINAL SCHEMATIC SPECIFIC TO THIS INSTALLATION AVAILABLE UPON REQUEST 0`c � � q INVERTER(S) AC DISCONNECT ti '✓�N y 0 ri 5z E E STANDARD EXTERIOR INTERCONNECTION: STANDARD INTERIOR INTERCONNECTION: D D REV: DESCRIPTION: DATE: PROJECT NAME: INTERIOR EXTERIOR INTERIOR EXTERIOR Nancy Szczotka PROJECT LOCATION: 50 County Rd 48,Peconic, MAIN TAP BREAKER MAIN NY 11958 SERVICE O 1 SERVICE O c PANEL ENCLOSURE PANELETTE PANEL PROJECT#: UTILITY UTILITY PROJ.PHASE: PERMIT METER METER DATE: B B DESIGNED BY: ED 1 CHECKED BY: GS SCALE: NTS TITLE: ELECTRICAL A A SHEET: SE-01 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER 9 Q L A R 4589 AUSTIN BLVD ISLAND PARK,11558 ENCLOSURE UTILITY TEL:516-837-3459 NEMA3R METER FAX:516-706-1789 BRANCH C BRANCH B BRANCH A WWW.EMPOWER-SOLAR.COM �� THE INFORMATION DISCLOSED HERIN IS THE SOLE (6)SPR 415W MODULES (10)SPR-415W MODULES (10)SPR-415W MODULES TO MAIN TO PROPERTY OF EMPOWER CES,U.C.UNAUTHORIZED TOTAL DC STC POWER:2.49 kW TOTAL DC STC POWER:4.15 kW TOTAL DC STC POWER:4.15 kW SERVICE UTILITY REPRODUCTION OR DISTRUBUTION OF THIS (6)ENPHASE IQ7HS MICRO-INV (10)ENPHASE IQ7HS MICRO-INV (10)ENPHASE IQ7HS MICRO-INV PANEL GRID MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR TOTAL AC POWER:2.304 kW TOTAL AC POWER:3.84 kW TOTAL AC POWER:3.84 kW AC4 SPECIFIC WRITTEN PERMISSION. CONTINUE AS CO..lMNLE AS CCNTIYLE AS REQUIRED FOR W.- REaJMDFOR INV._. REQUREDIFOR PIN.._ SUNPOWER PROFESSIONAL EN INEER SPECFEDSTFUMM SPECREDSTRSIGM SPECIFEDSiRIVGIYG DATA MONITORING AC DISCONNECT ACII AC7 ACI > > 150A,2P CB (1)SPR-415W MODULE tW 2 (1)SPR-415W MODULE I(W 2 (1)SPR-415W MODULE 14V.2 15A 2P CB (1)ENPHASE MICRO INV. (1)ENPHASE MICRO INV. (1)ENPHASE MICRO INV. ACI ACI ACI A 20A 2P CB OF (1)SPR-415W MODULE t�!1 1)SPR-415W MODULE Iw.1 (1)SPR-415W MODULE INV1 20f�2P CB ���N _�.A (1)ENPHASE MICRO INV. 1)ENPHASE MICRO INV. (1)ENPHASE MICRO INV. �'� 20q 2P CB PI.Of�VA , �AbLILA y acI ACI ACI �_ (D W � S LIJ m ? 'OESR _ oNP� Ac IFS TO RACI4NG G AC COMBINING MLO PANEL PROJECT NAME: GROUND NEMA 3R 1 -PHASE 120/240V SZCZOTKA RESIDENCE (1)#6 AWG,EGC ENCLOSURE LABEL DESCRIPTiCN LABEL DESORPTION ACI SPR AC CABLE AC2 1-112'PVC PROJECT LOCATION: (2)#12 AWG (6)#10 AWG (1)#10 AWG.EGC 50 COUNTY RD 48 AC3 3/4^PVC AC4 z PVC PECONIC,NY 11958 (3)#10 AYIG (3)#210 AWG (1)010 AWG.EGC (1)#4 AWG.GEC PROD.PHASE: PROPOSAL DATE: 12/4/2022 DESIGNED BY: SA CHECKED BY: GS SCALE: NTS NOTES: TITLE: 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR ELECTRIC SYSTEM) TOTAL SYSTEM SIZE: 10.79 kW 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN SERVICE PANEL USING IRREVERSIBLE SPLICE (26)SPR-415W MODULES PV ELECTRICAL SYSTEM 3.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) (26) ENPHASEIQ7HS MICRO-INV. 3-LINE DIAGRAM 4.SIZE GEC AND EGC AS PER NEC 240.66,NEC240.122 RESPECTIVELY - I� 'P P milii,vjt,ii,Lv NMI Simple and Fast Installation Integrated module-to-rail grounding i Pre-assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates consistent,even x= module spacing UL 2703 Listed integrated grounding. Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait with up to 8' rail span Pre-drilled rails and rail splice Rails enable easy obstacle management F - Customer-Preferred Aesthetics #1 module and#1 mounting aesthetics Elegant Simplicity Best-in-class system aesthetics Premium,low-profile design SunPower° InvisiMountTm is a SunPower-designed Black anodized components rail-based mounting system. The InvisiMount system Hidden mid clamps and new capped,flush addresses residential sloped.roofs and combines faster end clamps installation time, design flexibility, and superior aesthetics. Part of Superior System The InvisiMount product was specifically envisioned and Built for use with SunPower DC and AC modules engineered to pair with SunPower modules. The resulting Best-in-class system reliability and aesthetics New optional rooftop transition flashing,rail- system-level approach amplifies the aesthetic and mounted J-box,and wire management rail clips installation benefits—for homeowners and for installers. Combine with SunPower modules and SunPower EnergyLink®monitoring app —moos, J = 4 _ sunpower.com _�IIIIIII�iO��iI�IIIIQ�III �V= - - = 77 _ a` i t„�y fir, R,•� P•'.y-�, - •:��� � .T " ,ice .tot - L _ --�/�'i•:F • • •• - Moduler/Mid Clamp and Rall Module'/End Clamp and Rail Y" Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly(for DC systems only) n InvisiMount ComponentDetails InvisilMount0perating • • • Mid Clamp Black oxide stainless steel 300 series 63 g(2.2 oz) Temperature —40°C to 90°C(-40°F to 194°F). End Clamp Black anodized aluminum 6000 series 110 g(3.88 oz) 3000 Pa uplift Max.Load(LRFD) 6000 Pa downfor'ce Rail Black anodized aluminum 6000 series 830 g/m(9 oz/ft) Rail Splice Aluminum alloy 6000 series 830 g/m(9 oz/ft) Ground Lug 304 stainless steel '•• • , ••e • Uy UesipTbol Assembly (A2-70 bolt;tin-plated copper lug) 106.5 g/m(3.75 oz) Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Universal interface for other roof attachments' euRt Cornpo'nent LRFD CapacitieS2 Uplift 664 Ibf Mid Clamp Shear 540 IbfIiivlsi'Mount'Warra(iCiesAnd!Certiftcaflions Uplift 899 IV 25-year product warranty End Clarnp Warranties Shear 220 Ibf 5-year finish warranty Rail Moment:upward 548 Ibf-ft UL 2703 Listed Moment:downward 580 Ibf-ft Certifications 'Class A Fire Rated Moment:upward 548 Ibf-ft Rail Splice Moment:downward 580 Ibf-ft Roof Attachment'Hardware'Warranties, Uplift 1000 Ibf L-foot Shear 390 Ibf Refer to roof attachment hardware manufacturer's documentation. Module frame that is compatible with the InvisiMount system required for hardware interoperability. z SunPower recommends that all EquinoxTm,InvisiMountTm,and AC module systems always be designed using the SunPower Design Tool.If a designer decides to instead use the component capacities listed in this document to design a system,note that the capacities shown are Load and Resistance Factor Design(LRFD) design loads,and are NOT to be used for Allowable Stress Design(ASD)calculations;and that a licensed Professional Engineer(PE)must then stamp all calculations. Should you have any questions please contact SunPower Technical Support at 1-800-SUNPOWER(1-800-786-7693). sunpower.com (0 2017 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo,EQUINOX,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. 509506 RevE All other trademarks are the property of their respective owners.Specifications included in this datasheet are subject to change without notice. M SUNPOWER ° 420-440W Residential AC Module Sun Power'Maxeon Technology Built specifically for use with the SunPower Equinox°system,the only fully integrated solar solution designed,engineered,and warranted by one company. Highest Power AC Density Available. The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest efficiency AC solar panel available? E � E � E E larger Part of the SunPower- Equinox" Solar System j Highest Lifetime Ener and Savings •Compatible with � C , g 9Y g mySunPowerT"" monitoring I Designed to deliver 60% more energy over 25 years in •Seamless aesthetics real-world conditions like partial shade and high temperatures.z i 50 - - - - --- - - - -- -- - - -- - - - - i 1409 —— — 130% -_o 120% Up to y v 11o% 660%y i 100%, More v 9045 Lifetime II i 804 Energy Conventional Panel L— _ —— — —-- °nn' Goss i I l N G093 4 ! 0 5 10 15 20 25 Factory-integrated Microinverter Years of Operation i • Highest-power integrated I AC module in solar { Best Reliability,Best Warranty • Engineered and calibrated 1 With more than 42.6 million and 15 GW modules deployed around ` by SunPower for SunPower the world;SunPower technology is proven to last.That's why we AC modules stand behind our module and microinverter with the industry's ! best 25-year Combined Power and Product Warranty. l Datasheet M-Series: M4401 M435 I M4301 M425 I M420 SunPower° Residential AC Module AC Electrical Data Inverter Model:Type H(Enphase IQ7HS) @240 VAC @208 VAC Max.Continuous Output Power(VA) 384 369 Nom.(L-L)Voltage/Range'M 240/211-264 208/183-229 Max.Continuous Output Current(Arms)' 1.60 1.77 Max.Units per 20 A(L-L)Branch Circuit4 10 9 CEC Weighted Efficiency 97.0% 96.5% Nom.Frequency 60 Hz Extended Frequency Range 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor(adjustable) 0.85(inductive)/0.85(capacitive) DC Power Data Warranties,Certifications,and Compliance SPR-M440- SPR-M435- SPR-M430- SPR-M425- SPR-M420- •25-year limited power warranty H-AC H-AC H-AC H-AC H-AC Warranties .25-year limited product warranty Nom.Power6(Pnom)W 440 435 430 425 420 UL 1741/IEEE-1547 Power Tolerance +5/-0% UL 1741 AC Module(Type 2 fire rated) UL 61730 Module Efficiency 22.8% 22.5% 22.3% 22.0% 21.7% UL 62109-1/IEC 62109-2 [Temp.Coef.(Power) -0.29%/°C FCC Part 15 Class B p •ICES-0003 Class B Shade Tolerance Integrated module-level max.power point tracking CAN/CSA-C22.2 NO.107.1-01 CA Rule 21(UL 1741 SA)s Certifications (includes Volt/Var and Reactive Power Priority) and UL Listed PV Rapid Shutdown Equipment7 Tested • • Conditions Compliance Enables installation in accordance with: Operating Temp. -40°F to+185°F(-40°C to+85°C) NEC 690.6(AC module) Max.Ambient Temp. 122°F(50°C) NEC 690.12 Rapid Shutdown(inside and outside the Wind:125 psf,6000 Pa,611 kg/m2 back array) Max.Test Load' Snow:187 psf,9000 Pa,917 kg/m2 front NEC 690.15 AC Connectors,690.33(A)-(E)(1) Max.Design Load Wind:75 psf,3600 Pa,367 kg/m2 back When used with AC module Q Cables and accessories g Snow:125 psf,6000 Pa,611 kg/m2front (UL 6703 and UL 2238)': Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) •Rated for load break disconnect PID Test 1000 V:IEC 62804 Mechanical Data Packaging Configuration Solar Cells 66 Maxeon Gen 6 Modules per pallet 25 Front Glass High-transmission tempered glass with anti-reflective coating 75.4 x 42.2 x 48.0 in. Environmental Rating Outdoor rated Packaging box dimensions (1915 x 1072 x 1220 mm) Frame Class'l black anodized(highest AAMA rating) Pallet gross weight 1300.7 Ib(590 kg) Weight 48 Ib(21.8 kg) Pallets per container 32 Recommended Max. Net weight per container 41,623 Ib(18,880 kg) Module Spacing 1.3 in.(33 mm) 73.7 In 1 Based on datasheet review of websites of top 20 manufacturers per Wood Mackenzie US PV Leaderboard Q3 2021. [1872 mm] y I FRAME PROFILE 2 Maxeon 435 W,22.5%efficient,compared to a Conventional Panel on same-sized arrays(260 W,16%efficient, approx.1.6 m2),7.9%more energy per watt(based on PVSyst pan files for avg.US climate),0.5%/yr slowerTi 1 degradation rate pordan,et.al.'Robust PV Degradation Methodology and Application"PVSC 2018). E Grounding Holes 3 Voltage range can be extended beyond nominal if required by the utility. 4 Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. E h-A� 5 Factory set to IEEE 1547a-2014 default settings.CA Rule 21 default settings profile set during commissioning. qH 6 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25°q.All DC voltage is fully contained within the module. (A)Long Side:1.3 In(32 mm) 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12;and C22.1-2015 Rule 64-218 Rapid short side:0.9 in(24 mm) Shutdown of PV Systems,for AC and DC conductors;when installed according to manufacturer's instructions. 7 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. Please read the safety and installation instructions for details. See www.sunpower.com/company for more reference information. Specifications included in this datasheet are subject to change without notice. ©2022 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,EQUINOX and wrte�cmF MYSUNPOWER are trademarks or registered trademarks of SunPower Corporation in the U.S.MAXEON is aE�s °Qs °Q" 539973 RevB registered trademark of Maxeon Solar Technologies,Ltd.For more information visit www.maxeon.com/legal. LISTED Ed7e'3° M.M.Fir°Pe4°rme-Type2 January 2022 1-800-SUNPOWER : •• •