Loading...
HomeMy WebLinkAbout49157-Z �O�aSUFfOt y Town of Southold 6/17/2023 P.O.Box 1179 o - 53095 Main Rd y�o� dap!fr Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44184 Date: 6/17/2023 THIS CERTIFIES that the building GENERATOR Location of Property: 275 Harbor Rd, Orient SCTM#: 473889 Sec/Block/Lot: 26.-3-12 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/20/2023 pursuant to which Building Permit No. 49157 dated 4/25/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"accessory generator as applied for. The certificate is issued to Matthews,Catherine of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49157 5/17/2023 PLUMBERS CERTIFICATION DATED 0 Aut ori ed i ature OF SOUjyDI � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlina-town.southold.ny.us Southold,NY 11971-0959 Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Catherine Matthews Address: 275 Harbor Rd city,Orient st: NY zip: 11957 Building Permit#: 49157 Section: 26 Block: 3 Lot: 12 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Peconic Power Systems License No: 45056ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1 st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: Generac " Core Power" Generator w/ 50A 8 Circuit Automatic Transfer Switch Notes: " AS BUILT NO VISUAL DEFECTS " Generator Inspector Signature: c Date. May 17, 2023 S. Devlin-Cert Electrical Compliance Form OF SOUIyO� * TOWN OF SOUTHOLD BUILDING DEPT. Comm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL bwwAa%� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: T 4�&, oe� 4�� ( ml DATE INSPECTOR o�aOFSOOTyo l `S'-7 7S r - # TOWN OF SOUTHOLD BUILDIN D111C T- courm631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: f Al i DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (IST) •: H ------------------------------------ -50 e� i?Z C FOUNDATION (2ND) t17 r � z J ° 11� �3 ROUGH FRAMING& PLUMBING t � 1 r INSULATION PER N.Y. y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS 3 . G b( a h� a4 CF . o k ►o L � o z x H x d b H J 7`710 S�at't TOWN OF SOUTHOLD—BUILDING DEPARTMENT yS Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �� • o��� Telephone (631) 765-1802 Fax(631) 765-9502 haps://www.southoldtowm.gov Date Received APPLICATION FOR BUILDING PERMIT �j For Office Use Only PERMIT NO. ✓ Building Inspector: L U7LD" APR 2 0 2023 Applications and forms must be filled out in their entirety: Incomplete= SUILL311UG DEPT applications will not be accepted. Where the Applicant is'not.the owner,an. TOWN OFSOUTHOLD Owner's Authorization form(Page:2)shall,be completed: , Date: ' �U OWNER(S)OF PROPERTY: Name: C SCTM#1000- Project Address: �� 0Y"( &yv ,`r ( 1 15 Phone#: �,.� �.. j- Email: Mailing Address: ® �® v i L CONTACT PERSON: Name: �V�e— Mailing Address: Phone#: Email: DESIGN,PROFESSIONAL.INFORMATION: Name: �U Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: 'DY i - Name: pec-ov, PuWev- Mailing Address: Phone#: 3 y . v Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: VOther $ 101 o O G Will the lot be re-graded? ❑Yes ZNo Will excess fill be removed from premises? ❑Yes EKO 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to ©D� • { -51CI P�v1 r this property? ❑Yes MNo IF YES, PROVIDE A COPY. heck Box After Reading': The owner/contractor/design professional is responsible for all drainage and storm water issues as.provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a.Building Permit pursuant to the Building Zone Ordinance of the,Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions;alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name): La�t'ru K(kf+kew5 ❑Authorized Agent M116wner Signature of Applicant: Date: 2'O -6 STATE OF NEW YORK) S • COUNTY OF Ing 0414f:l ne- l4a Ith ew s being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Q W n er (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief, and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of �� ,20 23 Notary Public JAIME RODRIGUEZ (Votary Public-State of New York No.01 806332316 Qualified in Suffolk County PROPERTY OWNER AUTHORIZATION My Commission Expires Nov.02,2023 (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 o�SueFot,t�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT H xTown Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 W'y • oe� Telephone (631) 765-1802 https://www.southoldtownny.gov Floodplain Development Permit Application PROPERTY INFORMATION:LL Flood Zone: ��-� FIRM Panel: SCTM ;L#1000- aG- 3 j Address: 275 Afr/Joy- I& City: t e/✓T Zip: CONTACT PERSON: Name: C� iCrl �/jjju f f�j�Wf TPhone#: (061 -qq _1-:F5I Mailing Address: P ed)t 5 (34- Ori&yXA- by M5 PROJECT DESCRIPTION: WWF, SECTION A:STRUCTURAL DEVELOPMENT(CHECK ALL THAT APPLY) . Type of Structure Type of Structural Activity , I [R/Residential(1 to 4 families) - >_ ❑New structure ` ❑ Residential(more than 4 families) ❑ Demolition of existing strup 2 8 023 El Combined use El Replacement of existing strdctur'" APR ' 11 Non-residential 13 Relocation of existing structure _ WN 01m SO LITH ❑ Elevated ❑Addition to existing structure i���®FSO� OL® ❑ Flood proofed(attach certification) ❑Al ration to existing strVcture ❑ Manufactured Home Other: e ❑ Located on individual lot ❑ Located in manufactured home park o-rh SECTION B: OTHER DEVELOPMENT(CHECK ALL THAT APPLY) ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging ❑ Connection to public utilities or services ❑ Paving ❑ Placement of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑ Watercourse alteration (attach description) ❑ Excavation (not related to a structured development) ❑ Other development not listed (specify): Bq signing below I agree to the terms'and conditions of this-permit and certify to the best of my knowledge the information contained in this application is true and accurate. I understand that no work may start until a permit is issued.The permit may be revoked if any false statements are made herein. If revoked,all work must cease until_permit is re-issued. Development shall not be used or'occupied until a.Cert.of Compliance is issued.The permit will expire if no work is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority or.representative to make reasonable inspections to verify compliance. Iric._ Application Submitted By(print name): Signature of Applicant: Date: BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD c Town Hall Annex - 54375 Main Road - PO Box 1179 .' Southold, New York 11971-0959 mw "" Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(@.southoldtownny.gov - seand(cDsoutholdtownny.gov F'APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INF RMATION (All Information Required) Date: Company Name: Electrician's Name: c�l��l� License No.: M,6 Elec. email: Elec. Phone No: 5 16 r d q—-71ell ❑I request an email copy of Certificate of Compliance Elec. Address.: F0-60x-. 51,4- (-L.4e JOB SITE INFORMATION (All Information Required) Name: Ca.+ arise,Mw"ews Address: 1105 H eYRo" Cross Street: to vU �;vr,✓ R,0 aj. Phone No.: Bldg.Permit #: email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): �.ygp X�-q: 13",e 'i1 71` r,0gV v<aA [^`3� x" _,r +`,tl '�., r' C-c ti> t 41j, A lal, Square Footage: Circle All That Apply: Is job ready for inspection?: ® YES FINO F Rough In Final Do you need a Temp Certificate?: F-1 YES F� NO Issued On Temp Information: (All-information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire ReconnectOFlood ReconnectOService ReconnectQUnderground❑Overhead # Underground Laterals 0 1 1 H Frame Pole Work done on Service? Y N Additional Information: II PAYMENT DUE WITH APPLICATION rd' CJfG (,A C Vlj_j C,, rot ejp /- r - r BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD 1v AZ Town Hall Annex - 54375 Main Road - PO Box 1179 {' Southold, New York 11971-0959 s` Telephone (631) 765-1802 - FAX (631) 765-9502 r :f �F,f... rogerr(a-southoldtownny.gov seand(p�southoldtownny.gov Y''""'-"W ) 5 F'APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INF RMATION (All Information Required) Date: �/ u Company Name: CON,C &,A/' " Electrician's Name: ole+ License No.: M g- q.50- !5,-6 Elec. email: ���� o S . Elec. Phone No: S j6- _7Iq 01 request an email copy of Certificate of Compliance Elec. Address.: To (31)X 51 u �„�. A.1 3-!r JOB SITE INFORMATION (All Information Required) Name: Ca+&er►mc,Ma-t#In ewe Address: 11�5 H Q`go" Cross Street: ,kt*"vb p;�,r,,i R,0 qj-, Phone No.: fn�,l-+q6 Bldg.Permit#: !4115-17 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDESQUAREFOOTAGE (Please Print Clearly): 1ff-�'��` in I Square Footage: Circle All That Apply: Is job ready for inspection?- ® YES ❑ NO [—]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (Au Hnformation required) Service Size[-11 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground LateralsF-] 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 1 5UR y L I OF PROPERTY SURVEYED 05-20 SITUATE: ORIENT AMENDED 06-22-2000 TOWN OIyy` X50^U'TH�yOLyD�/ N 5UFF0000 LK -26 — 3 UNTY x12 SUFFOLK COUNTY,' I 'Y ' CERTIFIED TO: W E JEROME DIPANE CATHERINE DIPANE S JUN 2 3 I OF S00 t Zone AE (el=q) pt --------------------------------------- \t' p \� p _ ------- Zone AE - �p�a �- p� _ \�9 0 `. , do c), 0 t 6 q 61 9 ,b,QS y 0) A, � �p�zo� �b /�pR� Ir��'• � 30 '�. ^O�/ ss�ce Fp�Jv C) � pt 0� pry 0 /0 Q Q �40 ° 60 /?SFQ 8 ® C? 36, �6� �t NOTES: ' `tea MONUMENT FOUND �o,�N C. u -Unauthorized=]c=oat lana addition tae key PIPE FOUND 1 a=eons.a Ii[ensetl lantlreurveydr's Seal';e violation pf 9ett ion 7209, sud-d lv lef an 2. dl the Ne.York State Eaucattan Lev.' CSS :C L HEDGE — a yY dn,r tapneanirdn the original thea adoker E) _rkea kith a rfa,nel or the lana s rv',or's stamped see,ane Mabe—.1d....to be v.tta crus r ��• ceptes- •Certin'ttdm mel==ee.sere..alam fy tnet tnta AREA = 13,OG3 SF OR 0.30 ACRES o o aar.ay nae prepared 1n accordance r11h the ea- \• isting Code^1 pract ita far rano Surva Ya adapted by the Neo York State Associetion of professional O Land surveyors. Sam cerci neat tons anal]run only ELEVATIONS REFER TO M5L N6VD '2Q SUP on the pensdn for.nae in euraer. prepared, LANE) end his penal) to the title compenY• 9orernaan- telaaen.Y ono,and.np institution„steal Ir=on. eno the aaa l9^ales of the lendi"a lnstitu[lan. Ceriflce- FLOOD ZONE DE516NATION ANNOTATED t,ona are not transferable to additional ,nstittutidne FROM 'FIRM' MAPS PANEL #68 OF 1026 JOHN C. EHLERS LAND SURVEYOR GRAPHIG 5GALE:I"= 30' 6 EAST MAIN STREET N.Y.S.LIC.NO.50202 RIVERS EAD,N.Y.11901 _ _ 369-8288 Fax 369-8287 REF.E:VOBS%99-179 AC )Z& CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) `� 1 01/18/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Josh Mitchell Freedom Coverage Corp PHONE (631)709-2777 a No 80 Orville Dr Suite 100 EooREss: Josh@FreedomCoverageNY.com Bohemia, NY 11716 INSURERS AFFORDING COVERAGE NAIC# INSURERA: Midvale Indernity Company 27138 INSURED INSURER B: The Hartford Ins Company 29424 Peconic Power Systems LLC INSURERC: 315 Commerce Rd INSURER D: Cutchogue, NY 11935 INSURERE: INSURER F: COVERAGES CERTIFICATE NUMBER: 00000166-0 REVISION NUMBER: 7 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DD/YYYY) (MMIDDfYYYYI LIMITS A X COMMERCIAL GENERAL LIABILITY GLP1092481 05/28/2022 05/28/2023 EACH OCCURRENCE $ 1,000,000 CLAIMS-MADEDAMAGE O RENTED - PREMISES OCCUR PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 1.000.000 ]( POLICY JEC PRDT LOC PRODUCTS-COMP/OP AGG $ 2 000 000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident $ UMBRELLA LIAB FJ OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ B AND EMPLOYERS'LIABILITY WORKERS COMPENSATION 12WECAT7UBP 09/02/2022 09/02/2023 X STATUTE ERH ANY PROPRIETOR/PARTNERIEXECUTIVE YIN E.L.EACH ACCIDENT $ 1,000,000 OFFICERIMEMBER EXCLUDED? N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ 1,000,000 ribe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached It more space is required) As pertains to insureds operations CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold Building Department THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town Hall Annex 54375 Main Road ACCORDANCE WITH THE POLICY PROVISIONS. P.O. Box 1179 Southold, NY 11971 AUTHORIZED REPRESENTATIVE tit-,?, (JCM C 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD Printed by JCM on 01/18/2023 at 11:04AM AP R VED AS NOTED DATE: B.P.4 FEE: 'M BY: NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE ,LOOD ZON �� REQUIREMENTS OF THE CODES OF NEW E YORK STATE. NOT RESPONSIBLE FOR .-OMPLY WITH CHAPTER "46" DESIGN OR CONSTRUCTION ERRORS. "7LOOD DAMAGE PREVENTION V ITHOLD TOWN CODE. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF ' ' ZBA " ING BOARD !' ' TRUSTEES AI V�' nrn - CCUPANCY OR JSE IS UNLAWFUL ,,VITROUT CERTIFICATE OCCUPANCY ELECTRICAL I12°3SPECTIC)IM REOUIP-ED GENERAC® 7kWCorePowerTM System Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Power Rating • Digital LED Controller Model 005837-0 (Composite Polymer - Bisque) - 7 kW 60Hz • Automatic Transfer Switch r with Built-In Priority Load Center • Composite All Weather Enclosure ' - - t • Sound Attenuated Enclosure i. • External Main Circuit Breaker f. • Flexible Fuel Line Connector I • Composite Mounting Pad pAo.' GENS , � • Natural Gas or LP Gas Operation • 2 Year Limited Warranty • UL 2200 Listed c @us LISTED FEATURES O INNOVATIVE DESIGN&PROTOTYPE TESTING are key components of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. GENERAC'S success in "IMPROVING POWER BY DESIGN." But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing,reliability all Generac models. It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and life testing, plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA, NEMA, EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine. choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O SINGLE SOURCE SERVICE RESPONSE from Generac's dealer network O COREPOWER"': Offers an extreme value for those who desire automatic provides parts and service know-how for the entire unit,from the engine backup power at the most affordable price. to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES. Long life and reliability are • PROTOTYPE TESTED NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer • SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility. GENERAC® IIS A" GENERAC® CorePowerTM System - 7 kW features and benefits Engine •Generac OHV engine A durable,reliable powertrain for maximum power output. -Cast iron cylinder walls Rigid construction and added durability provide long engine life. 0 -Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. •Pressurized filtration system Better performance,less maintenance and significantly longer engine life. -Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. -High temperature shutdown Prevents damage due to overheating. *Spin-on automotive type oil filter Captures and collects harmful impurities with easy serviceability. Generator •Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. -Displaced phase excitation Maximizes motor starting capability. -Automatic voltage regulation Regulates the output voltage to±5%prevents damaging voltage spikes. •UL 2200 listed For your safety. Transfer Switch •Fully automatic Transfers your vital electrical loads to the energized source of power. •Remote mounting Mounts near your existing distribution panel for simple, low cost installation. •Flush mountable Can be installed between studs like a standard electrical panel. •UL listed For your safety. Controls -Auto/Off/Manual switch Selects the operating mode. -Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage. *Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 10-30 seconds. -Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. •Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. •Seven day exerciser Operates engine to prevent oil seal drying and damage between power outages. -Timed trickle battery charger Maintains battery charge level to ensure starting. •Main line circuit breaker Protects generator from overload. Unit -Weather protective enclosure Ensures protection against mother nature. Tool-less removal of roof and sides.Three lift-out panels for easy access to all routine maintenance items. Composite polymer enclosure will not rust and is ideal for harsh and coastal installations. -Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. •Small,compact,attractive Makes for an easy,eye appealing installation. •SAE Sound attenuated enclosure ensures quiet operation. Installation System •1ft. (305mm)flexible fuel line connector Easy installation. GENERAC® CorePowerTM System - 7 kW specifications Generator Model 005837-0 Rated.Maximum Continuous Power Capacity(LP) 7,000 Watts*- Rated Maximum Continuous Power Capacity(NG) 6,000 Watts* Rated Voltage - _.. _. 240 Rated Maximum Continuous Load Current—240 Volts 29.2/25 Main Line Circuit Breaker 30 Amp Phase . _ .. ..-_ - _ _.__.. . .1 - _ Number of Rotor Poles - 2 Rated AC Frequency 60Hz Power Factor 1.0 Battery Requirement(not included) Group 26R,12 Volts and 350 CCA Minimum Unit Weight(Pounds/Kilos) 250/113.4 Dimensions(L x W x H)in./mm 24.4 x 30.2 x 33/618.5 x 767.5 x 837 Sound output in dB(A)at 23 ft.(7m)with generator operating at normal load** 67 Engine Type of Engine GENERAC OHV Number of Cylinders 1 Displacement - 432cc Cylinder Block Aluminum w/Cast Iron Sleeve Valve ArrangementOverhead Valve - - - - - Ignition System Solid-state w/Magneto Governor System Mechanical _ — - Starter 12 VDC Oil Capacity Including Filter Approx.1.1 Qts./1,0L Operating RPM 3,600 Fuel Consumption Natural Gas ft3/hr(m3/hr) 1/2 Load 85(2.41) Full Load 148(4.19) Liquid Propane ft3/hr(gal/hr)[Liters/hr] 1/2 Load 36(0.99)[3.75] Full Load 46(1.26)[4.79] Note:Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges-5-7"water column(9-13mm mercury)for natural gas,10-121,water column(19-22mm mercury)for LP gas.For Btu content,multiply fta/hr x 2500(LP)or ft3/hr x 1000(NG).For megajoule content,multiply m3/hr x 93.15(LP)or m'/hr x 37.26(NG). Controls Digital LED Indicators -,Simple user interface for ease of operation. Mode Switch: Auto Automatic Start on Utility failure.7 day exerciser. Off Stops unit.Power is-removed_ emoved_Control and charger,still operate. Manual/Test(start) Start with starter control,unit stays on.if utility fails,transfer to load takes place. _Engine Start Sequence Cyclic cranking:16 sec.on,7 rest(90 sec.maximum duration) Engine Warm-up 5 sec. Engine Cool-Down 1 min. Starter Lock-out Starter cannot re-engage until 5 sec,after engine has stopped. 2.5 Amp timed Trickle Battery Charger Standard Automatic Voltage Regulator w/Overvoltage Protection Standard Automatic Low Oil Pressure Shutdown Standard Overspeed Shutdown Standard,72Hz High Temperature Shutdown Standard Overcrank Protection Standard Safety Fused - Standard **Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,IS03046 and DIN6271). *Maximum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content,ambient temperature,altitude,engine power and condition,etc. Maximum power decreases about 3.5 percent for each 1,000 feet(304.8 meters)above sea level;and also will decrease about 1 percent for each 6°C(10°)above 16°C(60T). GENERACO CorePowerTM System - 7 kW transfer switch Transfer Switch Features Model 005837.0 operated, mechanical) -held No.of Poles - . z • Electrically P Y Current Rating(Amps) 50 contacts for fast, positive connections. ;Voltage-.- 120/24010_ Utility Voltage Monitor(Fixed)" • Rated for all classes of load, 100% -Pick-up 80% equipment rated, both inductive and -Dropout 60% resistive. Return to Utility .. - - _ _ approx.15 sec. _ Exerciser weekly for 12 minutes' Standard ole, 250 VAC contactors. u�Listed - - y St-,8"' ndard • 2 ._ P Total of Pre-wired Circuits _ 8 No.15A 120V 5 • 160 millisecond transfer time. No.20A 120V 1 No.20A 240V - • NEMA 1 (indoor rated) enclosure is standard. No.30A 240V 1 No.40A 240V - • Flush mountable. No.50A 240v ,Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250_ Volts 10,000 _- Weight(Pounds/Kilos) 25/11.3 'Function of Controller Dimensions Mechanical Dimensions Amps Height Width De th GENERAL' H1 H2 W1 W2 D 18.5 in 23 in 10.5 in 15.38 in 3.4 in 50 470 mm 584 mm 267 mm 391 mm 1 86 mm H, (Mire Ranges Ams Neutral Lug Ground Lug 50 2/0-#14 2/0-#14 10 D� W1 ` G E ISI E FRAC® CorePower TM System - 7 kW available accessories Model# Product Description 005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product. 005865-0 ; Cold Weather Kit The CorePower cold weather kit is recommended for CorePower units installed in regions where the temperature regularly falls below 32°F(0°C). ] } 006003-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. dimensions Dimensions shown are approximate. Contact your Generac dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 637mm [32.65 In.] j GENER® N i L 762mm[3.0 in.] PEA GRAVEL MINIMUM 61&5mm 767.5mm [24.35 In.] [30.22 in.] FRONT VIEW RIGHT SIDE VIEW GENE RAC° Generac Power Systems,Inc. • S45 W29290 HWY 59, Waukesha,WI 53189 • generac.com ©2013 Generac Power Systems,Inc.All rights reserved. All specifications are subject to change without notice. Bulletin 0186720SBY-P Printed In U.S.A.05/29/13