HomeMy WebLinkAbout48691-Z gafFO!p Town of Southold 6/17/2023 y� P.O.Box 1179 C* _ :M. 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44181 Date: 6/17/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 990 Duck Pond Rd, Cutchogue SCTM#: 473889 Sec/Block/Lot: 83.4-12 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/10/2022 pursuant to which Building Permit No. 48691 dated 1/4/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to an existing single family dwelling as applied for. The certificate is issued to Campbell,Jeffrey&Jessica of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48691 5/22/2023 PLUMBERS CERTIFICATION DATED or' Signature " TOWN OF SOUTHOLD v�gUFfQ1K�=� 4'foo�° may BUILDING DEPARTMENT cm 2` TOWN CLERK'S OFFICE co SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48691 Date: 1/4/2023 Permission is hereby granted to: Campbell, Jeffrey 243 W 70th St Apt 3B New York, NY 10023 To: Install roof mounted solar panels to an existing single family dwelling as applied for. At premises located at: 990 Duck Pond Rd, Cutchogue SCTM # 473889 Sec/Block/Lot# 83.-4-12 Pursuant to application dated 11/10/2022 and approved by the Building Inspector. To expire on 7/5/2024. Fees: SOLAR PANELS $50.00 CO-RESIDENTIAL $50.00 ELECTRIC $100.00 Total: $200.00 Building Inspector pF SO�ryQl 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 Q Jamesh southoldtownny.gov Southold,NY 11971-0959 Q �yCOUNT`I BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Jeffery Campbell Address: 990 Duck Pond Rd city:Cutchogue st: New York zip: 11935 Building Permit#: 48691 Section: 83 Block: 4 Lot: 12 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Venture Home Solar LL Electrician: Jason P. Sampogna License No: ME-60556 SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel X A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency StrobeHeat Detectors Disconnect X Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 11.2kw Roof mounted PV solar system 1 60 amp disconnect with 1 125 amp exterior enphase IQ combiner Notes: Inspector Signature: Date: May 22, 2023 990 duck pond rd OF SOUIHp ��lY r ��V LACA POM61 # TOWN OF SOUTHOLD BUILDING DEPT. °`�cootrtv��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [�, ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS b FOUNDATION (1ST) y 4t -------------------------------------- 'FOUNDATION (2ND) z 0 ROUGH FRAMING& PLUMBING 1 r INSULATION PER N. Y: STATE ENERGY CODE ovv FINAL ADDITIONAL OMMENTS y0 7 p /' i + Le- 1* z �rn J � 0 z H x d b H FQL/r BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD C* Town Hall Annex- 54375 Main Road - PO Box 1179 Go • Southold, New York 11971-0959 'yjj� aO� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(aD-southoldtownny.gov - seand(aD_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 10=222 Company Name: Venture Home Solar LLC Electrician's Name: Jason P. Sampogna License No.: ME-60556 Elec. email: permittingny@venturesolar.com Elec. Phone No: El request an email copy of Certificate of Compliance Elec. Address.: 100 Charlotte Ave. Hicksville NY 11801 JOB SITE INFORMATION (All Information Required) Name: Jeffrey Campbell Address: 990 Duck Pond Rd. Cutchogue NY 11935 Cross Street: Phone No.: 516-318-6403 Bldg.Permit#: qz(pq I email: jesskap@gmail.com Tax Map District: 1000 Section: i3l Block: Lf Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Pv Solar panels roof mounted installation 11.2kw-28 modules-not structrural upgrades Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑NO Issued On Temp Information: (All information required) Service Size❑1 PhF-]3 Ph Size: A # Meters Old Meter# ❑New service[-]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑✓Overhead # Underground Laterals 1 2 R H Frame Pole Work done on Service? Y N Additional Information: U PAYMENT DUE WITH APPLICATION N O V 1 0 2022 u,,1T.MDr G DF-PT. TOA OF SOTJ s E-107--L� TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �g�• o� Telephone(631)765-1802 Fax(631) 765-9502 littps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT _ n � For Office Use Only jD1 PERMIT NO. IP9 I Building Inspector: NOV 1 O 2022 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted..Where the Applicant is not the owner,an ,BIDING DEPT. Owner's Authorization fo'rm.(Page 2)shall be completed. TOWN OF BOIJ'>[MOLD Date:10/27/2022 OWNERS)OF PROPERTY: ZProjName:Jeffery Cambell SCTM#s000- 83,- l.( - 17- Project ect Address:990 Duck Pond Road, Cutchogue, NY 11935 Phone#:516-318-6403Email:jesskap@gmail.com Mailing Address:990 Duck Pond Road,-Cutchogue,°NY. _11 -- CONTACT PERSON: Name: Marilu Medina- Permit Coordinator Mailing Address:100 Charlotte Ave. Hicksville NY 11801 Phone#:929-255-3307 ext. 1048 Emailpermittingny@venturesolar.com DESIGN PROFESSIONAL INFORMATION: Name:Patrick Busset Mailing Address:100 Charlotte Ave. Hicksville NY 11801 Phone#:929-255-3307 ext. 1048 Email:permitting ny_@venturesolar.com CONTRACTOR INFORMATION: NameVenture Home Solar LLC -Alex Yackery Mailing Address:100 Charlotte Ave. Hicksville NY 11801 Phone#:929-255-3307 ext. 1048 Email:permittingny@venturesolar.com DESCRIPTION,OF PROPOSED CONSTRUCTION- ' ❑New Structure RAddition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: [i]Other Pv Solar panels roof mounted installation 11.20 kw-28 modules-not structrural upgrades $59,584.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ii No 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes 9N IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for afl drainage and storm water issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(prhAt name):AI Yackery ®Authorized Agent Downer Signature of Applicant: Date: 10/27/22 STATE OF NEW YORK) SS: COUNTY OF 45SA,�J ) Alex Yackery being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor- Venture Home Solar LLC (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this L 1 day of NoiJ 2017, NOT P 3TRr1yE 0 YOR[ Registration No.02LU6407287 QuMed in Suffo ty PROPERTY OWNER AVTASRVAXJ1QAL- (Where the applicant is not the owner Jeffrey Campbell residing at 990 Duck Pond Road, Cutchogue, NY do hereby authorize Alex Yackery-Venture Home solar to apply on M IPP ehalf to the Town of Southold Building Department for approval as described herein. . � 1 I/Zc,-2-Z_ YOwner's Signature ate effrey Campbell S'T'EPHEN JOHN LUISE JR. Print Owner's Name NOTARY PUBLIC,STATE OF NEW YORK Registration No.02LU6407287 Qualified in Suffolk unty ff Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, Jeffrey Campbell residing at 990 Duck Pond Road,Cutchogue,NY (Print property owner's name) (Mailing Address) do hereby authorize Alex Yackea-Venture Home Solar (Agent) to apply on my behalf to the Southold Building Department. I/m""" i id l l hoz-Z - er's Signature) (Date) Jeffrey Campbell $T HENJOFINLUISEJx (Print Owner's Name) NO�pUBLJGSTATEOFNEWYORK Registration No.02LU6407287 Qualified in Suffolk until MY Commission Expitas venture so 100 Charlotte Avenue Hicksville, NY 11801 permittingny@venturesolar.com 11/07/2022 Town of Southold Building Dept 54375 Route 25 Southold, NY 11971 Re: Solar application submission for 990 Duck Pond Road, Cutchogue,NY 11935- Jeffery Cambell Greetings. Enclosed please find a Building Permit application for a solar installation at the above address.Included are 4 sets of plans,BP application,Workers Comp,Disability, and Liability forms, Suffolk License,PE Letter and Equipment Cut Sheets. In the event you have any questions or need anything additional, please email us at PERMITTINGNY@VENTURESOLAR.COM and we will respond immediately. Thank you and have a great day. Stephen Luise Permit Expediter NY 475.208.30811 stephen.luise@venturesolar.com venture solar i _.".�.: Suffolk County Dept. of I- Ibor, Licensing & Consumer Affairs -, I`-Ok'IF WROVEMENT LICENSE .. Name - < ALEX,",ODER E YACKERY �V.. . �_ chis cerifies that the Business Name )earer is duly licensed Ver:u:e F-,),re Solar LLC DBA Dy the County of Suffolk License Number: H-59758 Rosalie Drago Issued: 02/1512018 ._ Commissioner Expires., ? 112024 Suffolk County Department o Labor Licensing g & Consumer Affairs VETERANS MEMORIAL HIGHWAY * HAUPPAUGE,NEW YORK 11788 DATE ISSUED: 02/15/2018 No. H-59758 SUFFOLK COUNTY Hoine Improvement Contractor License ! This is to certify that Alexander E Yackery doing business as Venture Home Solar LLC DBA having furnished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York is hereby licensed to conduct business as a HOME IMPROVEMENT CONTRACTOR, in the County of Suffolk. NOT VALID WITHOUT Restrictions Additional Businesses DEPARTMENTAL SEAL H]1-Solar Venture Solar AND A CURRENT CONSUMER AFFAIRS ID CARD ,I I R©Salie Draga Comm, sinner .� i ---- - -- Suffolk County Dept.of Labor,Licensing&Consumer Affairs VASTER ELECTRICAL LICENSF Name JASQN P SAr,1POGNA ML Business Name • rys certifies:hal the )carer is only Ucensed VENTURF t-OVt SOLAR LLC DHA ,y the Counly of suffoW. License Number:ME•605% Rosalie Drago Issued: U5/14,2018 Ccrnn.yewrer Expires: 05/01,2024 YK Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW Board PART 1. To be completed by NYS Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier la.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Venture Home Solar, LLC 718-398-2259 100 Charlotte Ave Hicksville, NY 11801 lc.Federal Employer Identification Number of Insured or Social Security Number 47-4266827 Work Location of Insured (Only required if coverage is specifically limited to certain locations in New York State,i.e.,a Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Metropolitan Life Insurance Company 3b.Policy Number of Entity Listed in Box 1a Town of Southold 234439 53095 Route 25 3c.Policy Effective Period: PO Box 1179 October 1,2022 to September 30,2023 Southold, NY 11971 4.Policy provides the following benefits: R A. Both disability and Paid Family Leave benefits. ❑ B. Disability benefits only. ❑ C. Paid Family Leave benefits only. S.Policy covers: RA. All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B. Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as described above. Date Signed: November 7,2022 By:I KAZO,W1.�.�C.Lyt y (Signature of Insurance carrier's authorized representative or NYS licensed Insurance agent of that named Insurance carrier) Telephone Number: SPU Group Contracts@metlife.com Name and Title: India Wilkins,State Plan Consultant IMPORTANT: If Boxes 4A and SA are checked,and this form assigned bythe insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate Is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emalled to PAU(Mwcb.ny gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit, PO Box 5200,Binghamton,NY 13902-5200. PART 2. To be completed by NYS Workers'Compensation Board(Only if Box 4B,4C or 5B have been checked) State of New York Workers'Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed: By: (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number: Name and Title: Please Note. Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) YORK workers' CERTIFICATE OF STATE Compensation BoardNYS WORKERS' COMPENSATION INSURANCE COVERAGE 16.Legal Name Address of Insured(use street address only) 1b.Business Telephone Number of Insured Progressive Employer Management Company III,LLC Labor Contractor,for (718) 398-2259 leased workers to: Venture Home Solar,LLC.,dba:Venture Solar Electric 1c.NYS Unemployment Insurance Employer Registration Number of insured 100 Charlotte Ave Hicksville,NY 11801 1 d.Federal Employer Identification Number of Insured or Social Security Work Location of Insured(Only required if coverage is specifically limited to certain Number locations in New York State,i.e.,a Wrap-Up Policy) 47-4266827 2.Name and Address of Entity Requesting Proof of Coverage(Entity Being 3a.Name of Insurance Carrier Listed as the Certificate Halder) American Zurich Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"1 a" 53095 Route 25 WC 10-18-880-03 PO Box 1179 3c.Policy effective period Southold, NY 11971 4/1/2022 to 4/1/2023 3d.The Proprietor,Partners,or Executive Officers are included.(Only check box if all partners/officers inclued) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3 insures the business referenced above in box 1 a"for workers'compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box 7. The insurance carrier must notify the above certificate holder and the Workers Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box 3c,whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend,extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,licese or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carder refemced above and that the named insured has the coverage as depicted on this form. Approved by: Douglas Jones (Print name of authorized representative or licensed agent of insurance carrier) Approved by: �, L�w-� 11/7/2022 (Signature) (Date) Title: Vice President Telephone number of authorized representative or licensed agent of insurance carrier: (480)951-4177 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) ww.wcb.ny.gov A�® CERTIFICATE OF LIABILITY INSURANCE DATE(MM/11/07/2022 1f) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR N EGA71VELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Heather Ryan NAME: Protection Plus Associates Inc PHCN o No. : (973)579-6776 FAX No: (973)579-0111 PO Box 4 E-MAIL h an SBOnelnsurance.com ADDRESS: ry 96 US Hwy 206 North INSURERS AFFORDING COVERAGE NAIC 8 Augusta NJ 07822 INSURER A: Southwest Marine&General Ins Cc 12294 INSURED INSURER B: AmGuard Insurance Company Venture Home Solar LLC,Venture Solar Electric INSURER C: Selective Insurance Company Venture Solar Capital INSURER D: NJ Manufacturing 100 A/B Charlotte Avenue INSURER E: Hicksville NY 11801 INSURER F: COVERAGES CERTIFICATE NUMBER: 22/23 Master#4 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMEDABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRUUISK POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICYNUMBER M/DD MMIDD LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE7 OCCUR PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ 5,000 A Y Y GL202200012768 11/15/2022 11/15/2023 PERSONAL&ADV INJURY $ 2,000,000 GEMLAGGREGATE LIMIT APPLIES PER: GENERALAGGREGATE $ 4,000,000 X POLICY❑X JPEC F_�LOC PRODUCTS-COMP/OPAGG $ 4,000,000 OTHER: Per Proj capped agg limit $ 5,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident ANYAUTO BODILY INJURY(Per person) $ BOWNED X SCHEDULED Y Y VF-AU371260 08/22/2022 08/22/2023 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS IX HIRED X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per ecddent Un/Underinsured $ 1,000,000 UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS IJAB HCLAIMS-MADE AGGREGATE s DED I I RETENTION$ $ WORXERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY YIN STATUTE ER ANY PROPRIETOR/PARTNERIEXECUTIVE ❑ NIA E.L.EACH ACCIDENT $ OFFICER(MEMBER EXCLUDED? (Mandatory in NH) E.LDISEASE-EAEMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Commercial Auto Combined Single Limit $1,000,000 C Scheduled Autos S246749 08/22/2022 08/22/2023 Un/Underinsured $1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,maybe attached if more space is required) Description of Operations:Solar Panel Installation Certificate holder is included as an Additional Insured to the above captioned General Liability Policy for on-going&completed operations on a primary&non-contributory basis;Additional Insured to the Automobile Policy for work the insured is performing provided a written contract exists requiring such a status. Per the terms of the policy,coverage for an additional Insured is contingent upon an underlying written contract with the named insured requiring such coverage. There is a Waiver of Subrogation included in the General Liability,Business Auto 30day notice of cancellation except 10 for non payment of premium. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Route 25 PO Box 1179 AUTHORIZED REPRESENTATIVE Southold NY 11971 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD ELM J t I io S 10/19/2022 Jeffrey Campbell 990 Duck Pond Road Cutchogue, New York 11935 Re:Solar Panel Installation Dear Mr.Campbell, At your request, Patrick Bussett of Venture Solar LLC(NY license#105278), has carefully reviewed the existing roof framing and the proposed connection of the panels to the roof for the building referenced above. The following building codes were used in conjunction with the 2020 building code of New York State to generate pertinent design criteria: ASCE 7-10—Minimum Design Loads for Buildings and Other Structures International Building Code 2018 Edition (IBC) National Design Specification for Wood Construction 2015 Edition (NDS) Design Criteria: Design Gravity Load: Snow/Live Load =25 lbs/ftz, Dead Load=12 psf Design Wind Load: V,,it=135 mph; Exposure B, Risk Category 11 *Wind loads exceed seismic loads and therefore govern the design Field observations identified the following conditions: The new solar panels will impose an additional dead load of approximately 3 psf. Roof A&B consists of asphalt shingles over plywood sheathing supported by 2x8 rafters at 16"o.c.The rafters are sloped at a 26° pitch and have a maximum projected horizontal span of 15'-6"±. Roof C consists of asphalt shingles over plywood sheathing supported by 2x8 rafters at 16"o.c.The rafters are sloped at a 27°pitch and have a maximum projected horizontal span of 17'-6"±.The framing is assumed to be Douglas Fir#2 graded or better. The calculations determined that the existing framing has adequate capacity to support the PV panels as shown in our PV panel layout plan with no structural upgrades required. I therefore certify that this installation complies with the applicable codes and is acceptable for approval. Please feel free to contact me if you have any questions or concerns. Best, ��P K �, BUSS ¢ 105278 t`�0 Patrick Bussett, PE AROFESS1ONa� Email: patrick.bussett@venturesolar.com <t Road APPROVED AS NOTED DATE--� B.P.# q f COMPLY WITH ALL CODES OF :t FEE$2OO.06 NEW YORK STATE & TOWN CODES NOTIFY BUILDING DEPARTMENT AT AS REQUIRED AND CONDITIONS OF s ,; 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTION SOUTHOLD TOWN ZBA 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE SOUTHOLD TOWN PLANNING BOARD ; 2. ROUGH-FRAMING,PLUMBING, STRAPPING, ELECTRICAL&CAULKING SOUTHOLD TOWN TRUSTEES 3. INSULATION 4. FINAL-CONSTRUCTION&ELECTRICAL N.Y.S.DEC, MUSTBE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES-OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ELECTRICAL INSPECTION REQUIRED d isconned r ALL4 bc Ol tt5 I dL la6cic a d Additional Yl Certification I I Q Cce I May Be Required. y � , . f venture sotar° SOLAR ELECTRIC GENERATION INSTALLATION ON EXISTING RESIDENCE: 6.�u`r°m��m>N 11222990 Duck Pond Rd Cutcho ue NY 11935-1834 LISA bklyn, a (800)2M-4159 > > > SCOPE OF WORK 990 Duck Pond Rd,Cutchogue,NY SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR 11935-1834,USATING Jeffrcy Campbell's Resident. SITE PLAN ELECTRONIC UPON PS BEING APPROSYSTEVED AND/OR R WP O rrI®BOT7T7 E Solarl'anels:(28)CS3N-40DMS Modules f��9 (�V �''] BUILDINGS DEPARTMENT. Inverters:(28)IQSPLUS-72-2-IIS Micro-Inverters + II!—� Scale:ln6 =1•-0 NOTES Solar System DC Size:11.20KW AC Size:8.12KW 1tLJ� analyzed 1Ji ll�r•3 Q f-�h�.° LJ }Lt 3 y Solar Annual Production:12,332.IXI KWH f The existing roof structure for this project,as is or with the structural reinforcement specified on page S-000.00,lots been structurally Designed By:UNIRAC + / \ � O ��22 ///, x \; and has been determined to be capable ojsupporring the Date:10/27/2022 / \ loads imposed Ery•the installation ojthe proposed solar electrical NOV Revision# Approval Daze Description \\ generating system as described in these design documents. / / \ \\ / / \ There is tree,utility line or any\\\ other potential hazard dmf could come into contact 1c�,{pp�9v�t�ty�p/,�/� with any part of the solar electric generating system. DEPE APPLICABLE CODES AERIAL SITE VIEW TO W NaF.5011'�'TIMM D /.�;;:. � Y� \ ' ';;rvry •' ,^�_-. \ \ All proposed work shall meet the standards spccified in 0tc .FSA• , , o�4 `'; ';`r+.' r� / S'v , \ 2020 Rraidcnrial Code of Ncw York,2017 National electri ( cal V // '� _ ? code and all other applicable local and state building and fire �/ 7/ .odea. \� TT IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE EDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SHE IS ACTING UNDER THE Existing Tree (Typ. %i' k . <'\ . =;w_, \\\ DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY y >'^`�'%' �)� `" •; \ \\ ITEM SPECIFIED OR OTHERWISE INCLUDED ON TIM DESIGN DRAWING IN ANY WAY, -A? / /�T.y'�= ,-�;t)-�,{•fir l:^''•� fn,.:rte? ,;!_ '��::%_,.. ..,: 0 \ \\\ THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT SUPERVISION OF PATRICK BUSSEIT,R.A,NY ARCHITECT LICENSE#105276, • s / / ,�,'T'_>` _ 'j' "4,1 ,,>'t';._„ `,, ?: -r�,�,„`-; -- \ ACTING AS AN INDI VIDUAUSOLE PRACTITIONER REGISTERED ARCHITECT. / / r„ "i',� •"i ,_ ^it'_T)= �Y .:�JL.'�l;r"�n �4^.�n{V,' �..,.,.-.,'1 \ \\ (/�� _ �✓-�r,:i _ fir-.;;?�.- :,1�iy'.`;-_,....�: / / Property line MAP OF BLOCK DISTRICTS p Y 'a =� 'X, r,•"iii; ,.;3_'," U �amuzG) _.:_ - UaUo• _g,c S.rySoor / � � i <. • r•,- _, .; •� x '� , avJ.' vzy Existing Chimney 1:7- -` - 2p1 _-I Patrick O Bussett Venture Solar ` _ / / t; C,-"s'��-�" \ :�,-; •.•-',/ 67 West Stoklyn,NY 112 ,Bro2 d� ..y?0r:tcr e;•;a. - - / tx': r:j •"'-a �;<. :Z�:-y , License#105278 Pro osedy; / Micro-Inverters rte; '.?: / ,/ ��DI NfWY P Integrated solar Panel Installations => z-:`= GPS COORDINATES 41.03227, 72.51515 ,/ fi4`�'`' Tx %O X Existing Si.. DRAWING INDEX Driveway N �' \ ..0 p �py4?•,`.-' ;. ,/ P.E./R.A.Stamps/Signatures 1 Zoning Information,Site Plan Z-000.00 L� 2 Elevations and System Layout A-M.00 \\ \\ *=`` Y°". ~0/^� y, .aX{, 3 Site Plan 2001.00 \ ,zn✓j/v'�' '/f \ V7.s.+-�.,,!: ?+.�:XX /' 'f !/,{J✓�IiVVI/ 4 Racking and Load Calculations 5-000.00 6e, \♦ \ r.r ,:/"*`..�-'?. j. DOBS Stamps/ starts 5 Spreadsheet S-001.00 6 Labels&Solar Map Placard G-000.00 7StriogDiagram E-000.00 8 Label Shoct E-001.00 <� 9 Electrical 3-Linc&Labels E-((102.00 10 BOM G-000.00 v Existing Main Service Panel Location: Inside Garage LEGEND Proposed Addition A 9/9 y � / xisting Utility Meter Location: Outside ZONING INFORMATION, \\v l '• i\� SITE PLAN ExisliagBuildingProposed location AC Disconnect: Outside Ventilation n40-1 Z-000.00 N Proposed location Combiner box: Outside Scale:l/16"=1'-0" o = Obstruction Page 1 of 10 IT IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE ELEVATION LEGEND SYSTEM LAYOUT EDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SHE IS ACTING UNDER THE scdr.3116'=1'-0• DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY vennture s0--tar Proposed Micro-Inverters ITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. Vent Pipes 67 Wu1 S4 aro.tlxa,m 11_2C's THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT j J 44",16",12"Tall a�vw wretlomerotacmn Integrated solar Panel Installations `?.lir QQ SUPERVISION OF PATRICK BUSSETT,RA,NY ARCHITECT LICENSE#105278, (800)7.03-4158 tn 1t' ACTING AS AN INDIVIDUAL/SOLE PRACTITIONER REGISTERED ARCHITECT. 990 Duck Pond Rd,Cutchoo e,NY T "'Cr�Os Existing Skylight D Vent Box 11935-1834,USA �T 11?+ r z° —, Jeffrey Campbell's Residence 380 Ott) ,Vr Vent Fan Solar Panels: 28 CS3N-0OOMS Modules 260 � Existing Pipe Vents Inverters:(28)IQ8PLUS-72-2-US Micro-Inverters j Skylight Solar System DC Si-:1120KW AC Size:8.12KW o�ap[t' Existing Skylight (--'I SolarAnnual Production:12,332.00KWH Existing Pipe Vents Designed By:UNIRAC / Existing Pipe Vents Date:10/27/2022 Revision# Approval Date Description i c"o�do 3' ye / S cFsSG Fyry r� Ty sB ' � '�QQ� yq , ro�� rr26 2r8o°61 t' ods oq y ti � Existing Main Service Panel Location: Inside Garage Proposed location Combiner box: Outsid Existing Utility Meter Location: Outside ussett N Proposed location AC Disconnect: Outside Patrick BSolar Venture Solar Proposed Solar Panel Array On Microinverters integrated with the panels 67 WestSt,Brooklyn,78 11222 rte-' FDNY Fire Path License#105278 �di<er Side of the Roof FDNY Fire Path Microinverters integrated with ��PS��K eus r°�� Smoke ventilation Smoke ventilation Pe panelds 6"Min. ropose Solar Panel Array D y 105278 S10Np�� P.E./R.A.Stamps/Signatures �❑ ❑i 10/272022 DOB Stamps/Signatures 0 0[BOO OC��OO 5'-fi" 0000 0000 0000 0000 Enphase combiner panel with PV monitoring---] Solar Electrical Installation Existing Utility Meter PV AC Disconnect 1. Enphase AC Combiner Panel Existing Utility Meter 2. PV AC Disconnect ELEVATIONS,SYSTEM LAYOUT ELEVATION SOUTH WEST (Located Adjacent To Utility Meter) O ELEVATION SOUTH EAST A-000.00 O2 (RIGHT SIDE OF HOME) Scale:3/16"=1' (FRONT SIDE OF HOME) Page 2 of 10 FLOOR PLAN ELEVATION LEGEND venture solarG scWc:114-_1.-0. IT IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE EDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SIZE IS ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY Vent Pipes 67 Wal S%Brooklyn,Nr 11222 ITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. 44",16",12"Tall v'"""•`'°nnaenomeota.rmn THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT (00)2M-4158 990 Duck Pond Rd,Cutchogue,ATY SUPERVISION OF PATRICK JSOLF P, CT TI ARCHITECT LICENSE#105278, Vent Box ACTING AS AN Ih'DIVIDUAL/SOLE PRACTITIONER REGISTERED ARCHITECT. L: 11935-1834,USA Vent Fan Jeffrey Campbell's Residence Solar Panels:(28)CS3N-40OMS Modules Inverters:(28)IQ8PLUS-72-2-US NLcro-Inverters Skylight Solar Sy.tem DC Size:11.20KW AC Size:8.12KW' Solar Annual Production:12,332.00 KWH Designed By:UIQIItAC � ,� Date:10/17/2022 Revision# Approval Date Description ����oo�•� T� �s 6 �o �oA�o G�cp- .o r- �i Proposed Micro-Inverters PG >� Integrated solar Panel Installations . RQ ° �'o 3' 193c�SS Q a ,o �Cb o Gip Patrick Bussett Venture Solar 3' 67 West St,Brooklyn,NY 11222 License#105278 S ���o ti,8 ,• �F,OF NEW,, 6j auss���� ,A0 -1 105278 � s�4 QQt ESSIONP� �~ �? I 20 c4'yro . O")`x O e60 'l�o Q4 P.E./R.A.Stamps/Signatures �y t '614 ' 4. \ \ 10/27/1022 DOB Stamps/Signatures Proposed location Combiner box: Outside Proposed location AC Disconnect: Outside Existing Main Service Panel \ Location: Inside Garage \ Existing Utility Meter Location: Outside SUE PLAN Existing Driveway �\ Z-001.00 \�\ Scale:3/16"=1' \ Page 3 of 10 LEGEND venture so la r° UNIRAC STAGGERED FLASHLOC DUO ROOF ATTACHMENT �0 C53Na00MS 67,L..S4 Bm"Lyq NY I t.'= Solar P."�t< s" -h l Scale:3/16"=P-0" MICRO-INVERTER 31158 990 Duck Pond Rd,Cutchogue,NY ® ATI'-aclL'm-us 11935-1834,USA _____ RAFTERS leffrey Campbell's Residence Solar Panels:(28)CS3N-40OMS Modules Inverters:(28)IQSPLUS-72-2-US Micro-Invertcrs Roof A Roof B Acceptable Rail Mounting Area Solar System DC Size:11.20KW AC Size:8.12KW Solar Annual Production:12,332.00KWH -4 34'-3" L-Feet Rail Supports shall be installed at each 1' " I i end of rail and every 48"there after to support Designed By:UNIRAC ! 1 I I 2' 01 ! I0I 1 1 IQ ! ! loll all Solar array wind and snow loads.Roof Date:10/27/2022 l Revision N Approval Dau Description i f I I i i I I I i I I attachments shall be staggered. 101 I 1 1 1 I I I I I i l l l l l I I 1 1 t l l I I I I I � � � � � ! I I I � � � I I I I IT 15 A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE -6" ' I I 1 1 1 1 1 I I I I I I EDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SHE IS ACTING UNDER THE ]4'-g" ! I I I ' ' I I I I I I I I 1 B-9" DIRECnON OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER AN ITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY\VAY. Q I I I I I I IuI 1 1 I I I THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT I I I I { I I I I I I I 11 I I I I I ! I I I SUPERVISION OF PATRICK BUSSEIT,PLA,NY ARCHITECT LICENSE 8 105278, ! I I AC NG AS AN INDIVIDUAUSOLE PRACTITIONER REGISTERED ARCHITECT. I 7 I I I I ; i 4'-7" 14' 2" Unirac FlashLoc Duo Attachment @48" O.C. Roof C 15,_3" 7'-]" 7' 4'-9" 2"X8" Rafters @ 16" O.C. 6'-11" I i i 1,-4" I I I I l i l I I I 1 1 I I 1 I 19' ! IT— I I I I I i I I i I I I I I I I I I 4" 4" 3'-5" T-2" Patrick Bussett Venture Solar 67 West St,Brooklyn,NY 11222 ROOF STRUCTURAL DETAILS: License tl1U5278 Scale:3/16"=l'-0" �F OF NEly y ROOF TILT:261&25° *CRX Y,BpSSF�1 uL La:.rox - Ridge Beam AJ,x M'o= TIM" " �� 105278 Collar Tie 2X8 Rafters @ 16 O.C. A'�OFfSS10NA� S -Foot Installation Min. P.E./R.A.Stamps/Signatures �:. Roof A B " z6° 4. 1on72o22 \ DOB Stamps/Signatures �, .• / /�_ / LUge Beam Collar Ti 2"X8" Rafters @ 16" O.C. Y ` L-Foot Installation Knee Wall Roof C 25" 1Vlin. RACKING AND LOAD CALCULATIONS The PV modules will be maximum 6"off the roof surface. s-000.0 Scale:SEE SCALE Page 4 of 10 !.� solar- NXT HORIZON RAIL FLASHLOC DUO INSTALLATION NXT HORIZON RAILS MAX. SPAN ventuScale:1/16"=I-O" Scale:1/16"=1-0" 67 Wb S1,Bmaklyn,.'Y I1= GNMaximum Continuous Spliced Rail Length for NXT Horizon w'..Pn�a"s•m.Wm Rrp (800)]A3-SIs9 Q ' IN MIRAPART TABLE Rail with Stronghold Attachments(ft)/Maximum Reaction 1Z 990 Duck Pond Rd,Cutchogue,NY lIAA�` Force --- - PJtrl DESCRIPTION e s 11935-1834,USA ---'— _ DD9z7sM FLASHLOCDUDMILL 20 PACK eNor$oLTts �,_�F,_�'�t'- .�:�:,.r,:- -- ter-_..:r.:•-„ - -.-+-___ _._ ..-_. __.-.._...___ 7 _�.. -_. ___-_osviamnui--- _ -_ _ _ OPAIX NUi 3/8Y1'S5 Jeffrey Campbell's Residence .= - _ �O_R"I'CON�r, -=Y` '-m`L -- Fi --�+ _ - I I Lam'' Attachment Spacing -DI-SCOVERNO.UR �i JI �-" , DD5275D FLASHLOC D`JO DARK 2 SolazPanels;(28)CS3N-100M5Modules - ''---"'_"` -'`- `-" --'-`� _ --"" -•�- - ' - it,Eair�eaii�notrFttt�tlera2sole n T tu_des T ae''^�^ L- _ AT °F 24" 48" 72" Inverters:(28)IQSPLUS-72-2-US Micro-Invenea - --- - - _ - - ' -- -} - =;You(tSlEjEigee�l,)g;t;�rldclass�l(!�Or1;,r.Q�.rEI(able.:)P�IgAa�e;t?;T """-*'^- _ _ ' 40 67/155 94/218 117/272 Solar System DC Size:11.20KWACSize:8.12KW r-�n}iilQitLp10�`tih317?lekr.BeSCBilGde11111�3F!>/"1,iI1Rl70R'�Islt'Bh .L('tBl•_' =�=P'�s�" �= '�' �- 't:2'395.'4EVJ,HVRi,55,5E1F-DR r ,.� - - �.Y rt-ice r ;= fi;� = W1022 8°"°„�° 50 59/171 86/250 105/305 -DUESIGii'Slh(PiiCILl art�VALUE i.t __r,'::__:.l - ;' ri l-'" ; ;. �: Solar Annual Production:12,332.00KWH '..-.._..,_..,,,_._ .. _ - _ _ - - I -.:._,-.�__. -_ 60 55/191 78/272 93/324 Designed By:UNIRAC ::_.._--,.-:_'.i.:•- •�:c_-'--:. ._.�. -. :,_:_-- -- - - -- _ --- I .t ss seAw,TeD -- T... ._... - ...,:-..------_=-- .:'-I-moi-- 'is-- t.::: ��; _ I;. .•• _ «- �n�:�«6 _` `r_ m®. _ ��fi nAN emr� 1 . 70 51/207 70/285 81/329 Date:10272022 -�_ i:_ .-. .._ -. __ -- _ _ '1-r.,-`^_ - `� .. -.ti...._-_..�.._� _,c-.a.ema•a.r.o�-•_-•_-' ..--{-_.. ,,,-„•-. '�'.T.�"4:--ate.-'i-+• - - :P,'�.'ir�L_ __fi _ Revision# Approval Date Description ,.�_,... „ .-..,.- .._.,,,,,,b.,.. _.• .4 ,.-1,_.:j[,.._,.:...-._,-. , i ,._�:, _ _ _ --_ ci: i 80/372 1 80 471218 62/288 _ _ .fit , :. - - _ ��'a l j �q •� ,'a 90 43/225 62/324 69/361 �--+-- -:�.�.''-=--- ' ..' '�= ---•� 'moi'�. -•�, -i, - '.}_` 41, •i.:; .ter , -,--=-- ;�_—,-=�T•• '-- _,_--•--..;,_._._.__. .-..--..-- `, ;�; I =-, - X' 100 43/250 54/314 64/372 _ � '_' y• - ,,..- . =';,_ 120 39/272 53 369 53/369 sem— - ..:.:._._._�. � IAC :- _ y "' IT IS A VIOLATION OF ARTICLE 145,SECTION ?-,#y�;- +• "T '-'* --""I`= - -tt'�Tl- - ___ t• _ - FtAstnnc oro 14 35 285 0 20 2 OF THE NEW YORK STATE EDUCATION - ...'-..`. - - { - # `- _- 7 9() m•roma,.,,...�:-^.';,me�m�=r:'=;_�r i=-; _-nw.e.mamilz;%,' - '._..-'-E�!-«-::!.:.:�:.-.:_..Iasi__-. ... :a. LAW,FOR ANY PERSON,UNLESS HE OR SHEIS ; :-. v,•a>...c r�N'-:='tv cua_-..__. -;_. ._.--..-•- ' :_:: _''__ ACTING UNDER THE DmEcrloN OF THE - Maximum Continuous Spliced Rail Length for NXT Horizon -.:�T""'C•ca+JK,+eswd- -rtl-l._ _t_t-. _ - +r•--- Rail with Ftashkit Pro Attachments ft /Maximum Reaction LICENSED PROFESSIONAL ENGINEER OF .T' .tea-�r-.-•-�-- -.:.?.. `•;; T.: RECORD TO ALTER ANY ITEM SPECIFIED OR a:; -, - ......-----. .,_ c, _ .� '- {.-:, IN UDEDONTHISDESIGN ta�c°';•=I+:{'rh{- ,_�..:r:tL'-^^�� =-L:,-�- -'"�'•sl''. •1 � Force ills OTHERWISE CL G. r- ,. a ,. t �-):'�J.* -�-1 rvT;•; t�. =,-m.ra,P•I c,�-}-L: ,r-a.:,;_.mom...,_;_i.. � ,. ,y,-, ,,,i. R DRAWING IN ANY WAY. - _ra:: ----------- THESE - Attachment Spacing DESIGN DRAWINGS HAVE BEEN :....... -- ---- _- i-n - UNDERTHEDIRECT SUPERVISION __:._..-,_'.,I•<.--..•- =-.- ':"'.=''--- - -J.- PREPARED - ...Y - -'^r_ _ - - - AT 24" 48" 72" _,.:, 1-1-. ;a4v4---."®- -:eP4N:..1 .'�•"�f..>Q>ewt,s+,... «,--__`_ ).<:X>Wdtrsfb5%iti#i"-: — OFPATRICKBUSSETT,R.A,NY ARCHITECT ___i;-,,. � .}, > -,.,- .,,.:_,:-,_. gz>rn�j:;7.: - -- __ "`--'-. te.+"'; �!".. LICENSE#105278,ACTING AS AN i-._��--,���•��;1,�,,4,_-�..,,T. T•-_;,:,�,_. ' '` =�--` .' -� ��'1;-, - _•�_.,.-, -�F�� 40 75/139 102/189 129/239 INDIVIDUAL/SOLE PRACTITIONER '.',�:t=1*�*, ".i.l I.',n t, �i•_ +- - --1 'i)r-'_1 i1 _r• i_-`-�_.•"f'L -'--i i•-1-- -_�i 7»'i:jT,_,_, "l„s,"_ }. REGISTERED ARCHITECT. ,, , y, , , .,. , ,,, ,,, ,, , ,, , ,,, ,, -, , - , S' 50 67/155 94/218 117/271 60 63/175 86/239 1 105/292 70 55/178 78/253 93/302 �„+I ��' PRODUCTLINE: SOLARMOUNT DRAWING NOT TO SCALE 80 51/189 70/259 93/345 1 ALL DIMENSIONS ARE o 90 51/213 70/308 81/338 DRAW W G TYPE ASSEMBLY DETAIL NOMINAL Q 1931 SRONMNAY BLVD.NE 1 100 47/218 62/287 80/371 k3JQ,')eZQ'JF,V 97102 LGA DESCRIPTION: j FLASHLOC DUO IQT PRODUCT PROTECTED BY t>- V=E 5D5.24ZMU , ON-L OR MORE US PATENS 120 43/239 62/345 66/367 vMV.11OXCDN REVLSION DATE 4/29/2021 LEGAL NOTICE SHEET 140 39/253 54/350 57/370 INVERTER SPEC-SHEET COMBINER BOX SPEC-SHEET PV MODULE SPEC-SHEET Scale:1/16"=I-0" Scale:1/16"=1-0" Enphase 14 Combiner 414C MECHANICAL DATA 108 and IQ8+Microinverters uocuxuusee .,T.,nn.m,..•., - Specification Data Patrick Bussett G&LO " ..o b w�„•.,"H�E �" _ Cell Type Mono-crystalline Venture Solar ' �•�ma�:o->N Baa'---- mmr,�wc,. .+• m.:vv,,..,.-..>...w"�...."mc 67 West St,Brooklyn,NY 11222 ..�< �.L,rx, ,b>•<.e.,»Id,.o, i i�c„ ,.w; ..;.�.,e m„""i° r'aim'-`ate, — Cell Arrangement 132[2X(11X5)] ,¢„" 1 r>..,w„u.us.ru.e.,P,.mv�...e..us.w.la.a..:,.•.a..o-a.•wwW...•..,. --.- License#105278 �"ro. a-a, a.,, „m,.m.,ms,.�,,,,,,..,,e.mN•,m,�,�.nc.,.,.em�P.,,�.�.•..emar..,l..,. 1940X1048X35mm „,, -,_., 5° PCCE68e01eLFHDaEP°ACEUFMPACT6 (o-Pl.mwxame"«Pe,=+M Dimensions (76.4X41.3X138 in) �OFNE{y Weight 225 kg(49.6 lbs) 10 �D�•^•"*'^m''t+ ” ' - ...6 ;---_.--- -- -----s-er ;swTo- .�ao�;o.ea=�o.ta�.aelemre��. ;.- --'- - - Front Cover 3.2 mm tempered glass �'t ,`��GK BUSs��� »+..•brra.•x",r . �.�N.zPas,c�c.m.e°no Frame Anodized aluminium alloy oro v m�zP+..:aE.a,omm - .•.r«,sw�M mum•._,",awmeb,moem ,m,,.secr�ss :w.m.,.m.m°mo-w.00+, j .,.xPan.,e_tiE.oweea,se.,vmm m.Ta..w�+ -.r-- ...:•a+.ma,rmv,•axn.�.,ce.... ,e,�, }Box IP68,3 bypass diodes �P.�P>." x� ,", ,L---__-----------a�•�:>;=P:�m4"m�d:a--------------—-' Cable L) �� W r-: o •,..�,�,..�.P� xeo -- --------.. .,•mss b ao:,,re4r..- .�e...a d-i-----..-.__ N,m:m.�,P,l.u.�...•maar>,omemlma,,.,:r� .. >a xa,.»-�, ; I�'=:.._nP_.nu«c-_ e>_-.a.__..___-._-__....---�tem a,:;,-•�rn�<�.-:�%„�-�-N�---••-.a-i-P'�_*,_c_.-.-•�•-c-'--------------_ Portrait raiL400 ma(15 in)(+)/260 Cable Length ( ij )I landscape: U 05278(IncudingConnector) mm ��aC? ,,,,, ., m eo Irrrcrelcu sPECIPIcmoNs _ Connector T4 series or H4 UTX or MC4-EV02 OFESS10Np' sa•,mamm4""a. a x-m I .,•.. _. uo..dm e..n _ a Per Pallet 30 pieces Per Container(40'HQ) 720 pieces P.E./FLA.Stamps/Signatures �,m,,,,e„",c • - -- - „=tsaw,�he:;.;--�A--------- -- ------ --- - -- -- •Fvrdecalledinf—Uen,please contact your local Canaaian5olar sales and •Pm.vuwsm� ,e , •.-..__-_ - nrl _ _-.-.-vevmv:Pm`[„",xav-v.nr.vunza Cv"+a:.s.GCIL:.,.i-,ry,aa r.�en; N .GMM°Pa:4a,1�-s:+",) Otilwm'9-Ga�b^J•9 i Y�vu6rr1.rns8traam:drafnNO a]eCOr+euxai�rtaleSAv➢N4aeiv.E•msvo�Y.m+C y -'” c[:wd•beeel-•,.n ♦ n ¢ ..asvcm,rmL"euJ cr Clxm.t`i1r1_ — Pveaxeex�rot DOB Stamps/Signatures ���•�,�" YECNFMieFL0Ar9 fames - 8T1 r.p.•mn a':S�tm r:ou,sNv�nt sidavm wa a,.ar wxLm ear m.vaFl u+a,nn --__ _ - Is•r} - . onmu:DVHsn Tmm,^_�•1.,SmmP').]4xv32'1 l Wemm 9�m",mu ______ —.—_._-_._ Y,stN 4ay Cif , bet�bmNepa eo ui,4a��prvM.ma .can L9�a-Tv N��,G,,nam } �w®+enc�,smu��oz+,.,,"•, �-�'O0°'_'" 'OJ n°TFIbfFT eanNEcnon oenovs w�anon,. ovr •wonnl".r. rne.c+ [ORv rLl�'Y9f erte659SSalU9PFYnlib lT-0SNG Ca"a LR�f¢vermaa+".kietc++nrne® FvnnuWan/cava=-"a+,aG Muarrxelaefm, : —t,xhQntimt nax+,Yi+dla rt tep,lfve _- __ ' CePa]Msm.•:U.ute36sLLL:.vF1'£].•.r¢Hv,4a®B.ers-WCSaolrvees��x�xac:>T CObtllNLe Mm,.,aau3 I cmw�anc�= u°,vlc,x:a.r...o,c,L nc••.P.n:s a.:.6w anm.,x„• I,nwe�o-ucu..e...wProns.nwnrP.n.,.wxm.,:..e,racw va<cxors.,"eu,c.ea,rmn� � - -:`::-•e•� xra„ .v.ro"a�e.n xve+wwsw.a,.ac>isrv•.,.ra sc.,mx�m"n>..,..,,.-mm�en,mm I cmvw.r.nr, .,r _ �.,,w,••K,m.ro u.-a<r.m..s _ --- SPREADSHEET ". ..m� ®:��a �m�•�m�.m�a ENPHASE c 1 e,n.w.�q�mu,�""m•�m,r,w<a".�n�lnlna.w,.nv,,.m msmesoommm,sxrnuo To kam ma2rxin E+,N�e dfair�,mteefDF�..com acr+":..�.<,�-:+x v�ooy•00 m:m.e...a..s,.v .Rn,.,n".� >°:azm...,a E.cw�v.E.s.hn-• a..r� Eau,:corn a m,s.•n"e.�,cn Scale:SEE SCALE Page 5 of 10 PUSS SIZE CALCULATIONS MODULE SPEC-SHEET � � STRING CALCULATIONS - �,".,u�.a.--- CONDUCTOR SIZING CALCULATION L d ar (9)x 1.21A x 1.25=13.61A QOA->OK (28)x 121A z 1.25=42.35A=<60A fuse size ,„--,„� AMBIENT CURRENT '-',"'°"" CIRCUIT DESCRIPTION CURRENT lmax(690.(8Ap Icont(690.(8B)(2)(a) CONDUCTOR AMP90*C Ca COAD.OF USE A)cafe D 67West SLB-klyo?"y 11:22 (9)z1.21Ax125=13.61A QOA->OK �• --^••�•••••�-•^__ talc CONDUCTOR 90°C TEMPERATURE CARRYING (690.(BB)(2)(b)calc v„w.vmm yon=°>,a:°m (lU)x 1.21A z 125=15.13A<ZOA->OK - � -=-- -'� °C COND. =„ 40A z 0.96(amb,tem x (900)203-4158 -_- -""o„--^-----------` --_-_-_-_-------- PV SOURCE STRING 1 9.00 10.89 10.89 x 125=13.61 NI07NWN-2 40 31-35 I-3 Lll(raceway fill)=38.40A 990 Duck Pond Rd,Cutchogue,NY - w=� 40Ax(raceway fill) temp)x 11935-1834,USA _ PV SOURCE STRING 2 9.00 10.89 10.69 x 1.25=]3.6] q 10171R'N-2 40 31-35 1'3 1.0(raceway fill)=38.40A Jeffrey Campbell's Residence - -" Solar Panels:(28)CS3N-400MS Modules 40A x(raceway fill) temp)x PV SOURCE STRING 10.00 12.10 12.1Ox 1.25=15.13 010THWN-2 40 31-35 1-3 1.0(raceway fill)=38.40A Inverters:(28)IQ8PLUS-72-2-US Micro-Inverters 75A x(raceway fill) temp)x COMBINER BOX OUTPUT 26.00 33.86 33.88 x 1.25=42.35 tib THWN-2 75 31-35 1'3 1.0(raceway fill)=72.00A Solar System DC Sizc:11.20KW AC Size:8.12K\V Solar Annual Production:12,332.00 KWH 7x (arab.temp x AC DISCONNECT OUTPUT 25.00 33.88 33.BS x 1.25=42.35 #6 THWN-2 75 31-35 1-3 I.00((racewaewa y fill)=72.00A Designed By:UNIRAC TT Date:10/27/2022 IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE EDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SHE IS ACTING UNDER THE Revision# Approval Date Description DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY ITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT SUPERVISION OF PATRICK BUSSETT,R.A,NY ARCHITECT LICENSE#105278, ACTING AS AN INDTVIDUAL/SOLE PRACTITIONER REGISTERED ARCHITECT. String 1 ROOF A&B elf Bonding Panel and Rail 9 String 1 Line 1 String 1 Ground String 1 Ground String 2 ROOF A&B (3)L1 Red#10 Copper Conductors THWN-2 IT String 2 Line 1 3)ACPV Cables (3)L2 Black#10 Copper Conductors THWN-2 Solar Panels 9 String 2 Line 2 (1)Grounding Green#6 Copper Conductors THWN-2 (20)CS31,1-40oMs(400w) String 2 Ground Length of Conductor.35' Bond Conduit Length of Conduits:35' String 3 ROOF B&C I"EMT Aluminum Conduit IT String 3 Line 1 10 String 3 Line 2 c--------- String 3 Ground a SolaDeck Bond to Equipment Junction Box ROOF TOP SIDE OF BUILDING GARAGE SIDE OF BUILDING (3)L1Red#10Copper Conductors THWN-2 (3)L2 Black#10 Copper Conductors THWN-2 (1)Ll Red#6 Copper Conductor THWN- (1)Grounding Green#6 Copper Conductors THWN-2I (1)Ll#6 Copper Conductor THWN-2 (1)L2 Black#6 Copper Conductor THWN-2 Length of Conductor:35' (1)L2#6 Copper Conductor THWN-2 (1)Neutral#6 Copper Conductor THWN-2 Length of Conduits:35' (1)Neutral#6 Copper Conductor THWN-2 (1)Grounding Green#6 Copper Conductor THWN-2 1"EMT Aluminum Cond 't (1)Grounding#6 Copper Conductor THWN-2 Length of Conductor-5' Length of Conductor:10' Length of Condu its:5' ° Grid Length of Conduits:10' 1"EMT Aluminum Conduit 1"EMT Aluminum Conduit O Line Side Interconnection Arc Insulated Terminal Blocks J Existing Utility Yeif swa Meter Socket V m (New Net Meter) Existing Murray -_____ --Not To Exceed--------- Meter#98300675New Exterior 125A 2/ 10 ft 60A Account#9624516354 120/24240V Main Breaker Enphase � Main Panel IQ Combiner 4 (X-IQ-AMl-2400 DOB Stamps/Sinatures (1)Grounding#4 Conductor pF NEW y �tQ GK BU ;P, New Exterior PV AC DISCONNECT * QQ lit 89L Type 3R Enclosure 1/2"GEC Water Main--_, 60A A/C Disconnect,Baton D0222NRE (1)Grounding#4 (Located Adjacent to Utility Meter) lar Conductor 2 V W,^ 105278 Supplemental Ground Rod A��fESS10NP\ GEC ELECTRICAL 3-LINE& LABELS E-002.00 Scale:NTS Page 9 of 10 IT IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE /� �, EDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SHE IS ACTING UNDER THE !�l" fntru re.- sol'--Aar - ITEM SPE DIRECTION OR OTHERWISE INOF THE LICENSED CLUDED ON THISESIGN DRAWING INA ALTERSIONAL ENGINEER OF RECORD,TO AY, VENTURE SOLAR _ _ THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT 67 wu�sc,Broomya,xr 11222 - - - SUPERVISION OF PATRICK BUSSETT,R.A,NY ARCHITECT LICENSE#105278, wo wmmbomaotar.com - _ _ _ (800)2M-4158 - ACTING AS A INDIVIDUAL/SOLE PRACTITIONER REGISTERED ARCHITECT. 990 Duck Pond Rd,Cutchogue,NY Customer Name Jeffrey Campbell 11935-1834,USA Customer Address 990 Duck Pond Rd,Cutchogue,NY 11935-1834, USA Jeffrey Campbell's Residence Solar Panels:(28)CS3N-400MS Modules - - Team UNIRAC Inverters:(28)IQ8PLUS-72-2-US Micro-Inverters - - ROOF ELECTRICAL Solar System DC Sire:11.20KW AC Size:8.12KW _ _ - - - , Solar Annual Production:12,332.00KWH Description - Qty., Bar Code Description Qtr. `Bar Code- , Designed By:UNIRAC CAD 400 28 Enphase IQ Combiner 4 1 Date:10/27/2022 Portrait QCable-#Conn 29 Enphase Mobile Connect 1 Revision# Approval Date Description Landscape QCable-#Conn 5 Enphase 1Q7 Micro 0 Q Term 4 Enphase IQ7+Micro 0 Q Seal 11 Eaton 20 A Breaker 3 Q-Conn 10M 2 IPC-410-#6(Taps) 2 Q-Conn 10F 2 60 A Disconnect 1 Micro Inverter T Bolt 30 60A Set of Fuses 1 Wire Restraints 4 100 AMP Disconnect 0 Ground Lug 12 100A Set of Fuses 0 Pitched ROOF 125ACombiner Panel 0 F1ashLoc Duo Box(Qty.20) 4 Square D 100AMain Breaker 0 Unirac Rail 17 Square D 20 A Breaker 0 Unirac Splice 8 Square D 15A Breaker 0 Unirac Ends 49 Enphase IQ Envoy 0 Unirac Mids 33 Enphase 1Q7AMicro 0 Solar Seal 3 Enphase 108 Micro 0 Solar Deck 4 Enphase IQ8+Micro 28 Consumption CT 1Sets 200 Enphase IQ8M Micro 0 Fire and Smoke detector x 1 No No Enphase 1Q8H Micro 0 Battery Details Manufacturer Type: _ _ Mfr,Part No.&"Descriptioq, __9ty- Enphase Energy Inc Battery ENCHARGE-10TAP-INTAC Battery 0 Enphase Energy Inc Other EP200G101-M240US00 Enpower 0 Enphase Energy Inc Monitor COMMS-KIT-01 (Ensemble) 0 FLAT ROOF`;': = CONFIRMATION; r Chemlink 6"E-curb Kit 0 L-Foot Box w/Nut&Bolt(Qty.24) 0 4"Stand Off 0 Procurement Team Signature Unirac Tilt 18-30" 0 Unirac Tillt 26-44" 0 Unirac Tilit 40-72" 0 Crew Foreman Signature Silver Unirac Rail 0 Silver Unirac Splice 0 . Silver Unirac End 0 DOB Stamrs/Si natures Silver Unirac Mid 0 ��OF NEW y 4"Lag 0 *htQp��GR BUSSF�O.P�t 8"x8"x4"Junction Box 0 105278 ti n. 2 SSIDNP���� BOM G-001.00 Scale:NTS Page 10 of 10 IT IS A TION OF E 145, 209(2)OF NEW YORK TATE venture War- EDUCATION LAW,FOR ANY PERSON,UNTLESS7HE OR SHE.ISACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY w Wes:s4,,Doom.NY tt222 ITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. --h—..I— (800)203-4158 THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT 990 Duck Pond Rd,Cutchogue,NY ACTING ASN OF PATRICK ANIN'DIVIDUALISOLE r&A,NY ARCREGI TE tRED ARCHITECT 11935-1834,USA Jeffrey Campbell's Residence Solar Panels:(28)CS3N-00OMS Modules Inverters:(28)IQ8PLUS-72-2_US Micro-lavenen Labels comply with NEC 110.21(B) and ANSI 2535.4 Solar System DC Sim:1120KW AC Size:8.12KW SolarAnnual Production:12,332.00 KWH Design ed By:UNIRAC Date:10/27/2022 Revision# Approval Date Description COMBINER PANEL - - - JUNCTION BOX AC Output Current: 33.88A COMBINER PANEL Nominal Operating AC Voltage: 240V ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS AC DISCONNECT PHOTOVOLTAIC SYSTEM ARE AC Output Current: 33.88A A/C DISCONNECT UNGROUNDED AND MAY BE Nominal Operating AC Voltage: 240V ENERGIZED COMBINER PANEL r ''- MAIN DISTRIBUTION PANELA, ` C, U _! I__�N_ INVERTER OUTPUT CONNECTION; DO NOT RELOCATE THIS TWO POWER SOURCES INSIDE OVERCURRENT DEVICE UTILITY AND SOLAR PV J 1 - 10N BOX vitt.ti S ' S . • , -- - - • • Patrick Bussett Venture Sol CONDUIT EVERY 10 FT 67 Wes[St,Brooklyn, NY]1222 License#105278 ,,OF NEW y SOLAR • ! *c�t0. RAPIDWITH • � W y TURN RMD SHUTDOWN RAPID SHUTDOWN JFpp�o 05278 SWITCH TO THE"OFF' SYSTEM FESSION POSITION TO SHUT DOWN CONDUCTORS OUTSIDE P.E./R.A.Stamps/Signatures THE ARRAY.CONDUCTORS WITHIN THE ARRAY REMAIN NUGHTIN �?�4r �'�'2(/�/j SUNLIGHT.. - Lo/z7lzozz DOB Stomps/Sinatures SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AT RAPID SHUTDOWN TURN RAPID SHUTDOWN � SWTDTHEro� SYSTEM POSIDONTO SHUT DOWN W SYSTEMAND REDUCE SHOCKHA7AR0INTHE ARRAY. LABELS G-000.00 Scale:NTS Page 6 of 10 1j fid' 'I(' C�µ� ` IT IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE `�Lh''gyp W, H e ���sss EDUCATION LAW,FOR ANY PERSON,UNLESS HE OR SHE IS ACTING UNDER THE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY sr wut st sroot5m.n7 t t_2 mnn��ma.00m String Diagram ITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. (am)203-4158 THESE DISIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT 990 Duck Pond Rd,Cutchogue,IVT' SUPERVISION OF PATRICK BUSSETT,R.A,NY ARCHITECT LICENSE#105278, 11935-1834,USA ACTING AS AN INDIVIDUAL/SOLE PRACTITIONER REGISTERED ARCHITECT. Jeffrey Campbell's Residence Solar Panels:(28)CS3N-400MS Modules Inverters:(28)IQSPLUS-72-2 US Nficro-Invenm Solar System DC Size:11.20KW AC Size:8.12KW Solar Annual Producrion:12,332.00 KWH Designed By:UNIRAC Daze:10/27/2022 Revision# Approval Date Description ROOF B (13) CS3N-400MS (400W) AZIMUTH: 38° TILT: 26° 21 Enphase IQ8PLUS-72-2-US String 2 18 1 27 28 22 N icro-Inverters O ROOF C 15 1 20 (03) CS3N-400MS (400W) AZIMUTH: 38° TILT: 25° 14 = 3 26 25 24 23 String 3 O O O 0 �19 0 (n O CD F 10 11 X12 I 5 6 7 8 9 Patrick Bussett E79 - Venture Solar 67 West St,Brooklyn,A'Y 11222 License#105278 ut ntwy c" Y,8ussf��� Q r 4 3 2ELL05278 1> jO'�OfESS10Np�� a P.E./R.A.Stamps/Signatures C A ROOF String 1 lorz7rzoz2 DOB slam 5/ss azures (12) CS3N-400MS (400W) AZIMUTH: 218° TILT: 26° String Diagram E-000.00 Scale:NTS Page 7 of 10 IT IS A VIOLATION OF ARTICLE 145,SECTION 7209(2)OF THE NEW YORK STATE EDUCALabels Sheet DIRECTION FTHELCEAW,FOR NEDROFESSILESSHEOR SHE GINEER OF ACTING ,TORNDER THEE DIRECTION OF THE LICENSED PROFESSIONAL ENGINEER OF RECORD,TO ALTER ANY ITEM SPECIFIED OR OTHERWISE INCLUDED ON THIS DESIGN DRAWING IN ANY WAY. sr Wui s4 R—ktyn,Nr 11232 THESE DESIGN DRAWINGS HAVE BEEN PREPARED UNDER THE DIRECT a .xnnmhomaola.— SUPERVISION OF PATRICK BUSSETT,RA,NY ARCHITECT LICENSE#105278, (8009 703-0158 ` ACTING AS AN INDIVIDUAL/SOLE PRACTITIONER REGISTERED ARCHITECT. 990 Duck Pond Rd,Cutchogue,NY 11935-1834,USA Jeffrey Campbell's Residence Solar Panels:(28)CS3N-40OMS Modules Inverters:(28)IQSPLUS-72-2-US Micro-Inverters String Number Module Number Sticker 19 Solar System DC Size:1120KW AC Size:8.12KW Solar Annual Production:12,332.00 KWH Designed By:UNIKAC 1 2� Date:10/27/2022 Revision# Approval Date Description 2 21 3 22 4 23 3 1 5 24 6 25 7 26 g 27 9 28 Patrick Bussett Venture Solar 10 67 West St,Brooklyn,NY 11222 License#105278 OF NEWy 11 *�4 R�elt 1?usS��o� 12 y" 105278 Z ESS10Np�� 13 P.E./R.A.Stamps/Signatures 2 14 '', �i�rs' 10/27/1022 DOB Stam s/Si natures 15 16 17 Label Sheet 18 E-001.00 Scale:NTS Page 8 of 10 UNIRAC do U N I RAC MEN M))HORIZON BETTER SOLAR STARTS HERE DISCOVER Y NXT H NXT HORIZON'COMBO CLAMP AR DARK:CCLAMPDI -- ' MILL:CCLAMPMI 25 YE The culmination of over two decades of experience,Thoughtful design, alrecarail blesjWrhere(even where Self-stanrigorous engineering,world-class support,and a reliable supply chain are the combines as bothmpdandandc WARRANTY , , 1 combines as both mid aril end clamp. foundation of what makes us confident that NXT HORIZON'is the NXT Level Clamps 30-40 mm modules of DESIGN,SIMPLICITY,and VALUE, �> STRONGHOLD"RAIL CLAMP DARK:SHCLMPDI 1/2 inch module spacing for efficiency. MILL:SHCLMPIs11 NXT HORIZON' Unlmc-quality banding that works both as CAP KIT Adaptable rail connection to attachments mid and end clamps. allowscllck-in feature compalibdilywith ENDCAP01 —� almost all of Unirac's attachments. 0—ala Make the Install look clean with the and cap kit designed to complement the madule end clamp and rail ends. NXT HORIZON'RAIL WIRE MANAGEMENT OPTONS HashLoc technology combined with new features:click-In rail&open slot L-Foot for DARK:ISBRLDI the best flash-less Install experience. MILL:168RLMI Strong,lightweight open channel rail with Invisible,easy,unfailing STRONGHOLD`ATTACHMENT KIT and integrated wire management system. DARK:SHCPKTOI MILL:SHCPKTMI Rail clicks Into the clamps attached to the NXT HORIZON'RAIL SPLICE Stronghold"'base.Open slot in L-foot allows drop-in rail clamp. RLSPLCFII NXT HORIZON'MLPE&LUG CLAMP NXT HORIZON'WIRE MANAGEMENT CLIP NXT HORIZON'NORTH/SOUTH WIRE MANAGEMENT CLIP Structural inlemal splice that does LUGMLPEI WRMCLPDI Alternative attachment options Structural not interfere with root connection Works as either MLPE Mount or Grounding Aesthetic.yet functional accessary that works to nor module connection. Lug connection to the rail.Why source two help installers keep wires inside the rail. An elegant solution to help installers get to the so axxcoxs FLISITYJT Pea rusumc2 5uo Fre-assembled thread cutting bolts parts when one can do the job? No azip-tiles management required.Oplionalzip tie loop for extra home easy eThe ntry to r hardware works to provide aivmc::o asrx oa<osso orsxooszrm wire management capabilities! both easy entrylo rail and adjuslability for cable u:waa4assu M oo4zhsa thickness. I . , FREE PERMITTING PLANSET DESIGN FOR QUESTIONS OR CUSTOMER SERVICE UNIRAC.COM OR EMAIL NXTPERMITS@UNIRAC.COM CanadianSolar HiDM High density MONO PERC module 40OW-42OW CS1U-400140514101415142OMS MORE POWER UP TO Maximize the light absorption area, 2o.a�o module efficiency up to 20.4 Low temperature coefficient(Pmax): enhanced product warranty on materials -0.37%/°C 5 and workmanship* W4. Better shading tolerance 25 linear power output warranty* MORE RELIABLE *According to the applicable Canadian Solar Limited Warranty Statement. ............................................................................................................................... Lower internal current, MANAGEMENT SYSTEM CERTIFICATES* lower hot spot temperature ISO 9001:2015/Quality management system ISO 14001:2015/Standards for environmental management system OHSAS 18001:2007/International standards for occupational health&safety Cell crack risk limited in small region, l�J enhance the module reliability PRODUCT CERTIFICATES* IEC 61215/IEC 61730:VIDE/CE/MCS/K5/INMETRO Heavy snow load up to 5400 Pa, IEC 61701 ED2:VDE/IEC 62716:VDE wind load up to 2400 Pa* UNI 9177 Reaction to Fire:Class 1/Take-e-way pVE \ L 10" �'�-,,',��, ERT As there are different certification requirements Indifferent markets,please contact your local Canadian Solar sales representative for the specific certificates applicable to the products in the region In which the products are to be used. ............................................................................................................................... CANADIAN SOLAR INC.is committed to providing high, quality solar products,solar system solutions and services to customers around the world.No.1 module supplier for quality and performance/price ratio in IHS Module Customer Insight Survey.As a leading PV project developer and manufacturer of solar modules with over 40 GW deployed around the world since 2001. *For detail information,please refer to Installation Manual. ............................................................................................................................................................................................................................................................ CANADIAN SOLAR INC. 545 Speedvale Avenue West,Guelph,Ontario N1 K 1 E6,Canada,www.canadiansolar.com,support@canadiansolar.com ENGINEERING DRAWING(mm) CS1U-405MS/I-V CURVES Rear View Frame Cross Section A-A A A 171 1� 2 12 11 11 0 - 10 ❑ 9 9 8 6 9 7 owtlng Hale 66 5 5 4 a).lo 4 _Hae Mounting Hole 3 3 -- - 2 MA z o v o v 5 10 15 20 25 30 35 40 45 50 55 5 10 15 20 25 30 35 40 45 50 55 0 1000 W/m' 5°C 6m5 ow u.g o A A � 0 800 W/m' 25°C� ® 600 W/m' 45°C■ 400 W/ml 65°C ® 200 W/m' ELECTRICAL DATA STC* MECHANICAL DATA CS1U 40OMS 405MS 41OMS 415MS 420MS Specification Data Nominal Max.Power(Pmax) 400 W 405 W 410 W 415 W 420 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp)44.1 V 44.3 V 44.5 V 44.7 V 44.9 V Dimensions 2078 x992 X35 mm Opt.Operating Current(Imp)9.08 A 9.16 A 9.23 A 9.30 A 9.37 A (81.8 x39.1 x 1.38 in) Open Circuit Voltage(Voc) 53.4 V 53.5 V 53.6 V 53.7 V 53.8 V Weight 23.4 kg(51.6 lbs) Short Circuit Current(Isc) 9.60 A 9.65 A 9.70 A 9.75 A 9.80 A Front Cover 3.2 mm tempered glass Module Efficiency 19.4% 19.6% 19.9% 20.1% 20.4% Frame Anodized aluminium alloy Operating Temperature -40°C-+85°C J-Box IP68,4 bypass diodes Cable 4.0 mm2(IEC) Max.System Voltage 1500V(IEC)or 1000V(IEC) Cable length 1000 mm(39.4 in)(+)and 640 mm Module Fire Performance CLASS C(IEC 61730) Max.Series Fuse Rating 15A (Including connector) (25.2 in)(-)*;leap-frog connection: 1780 mm(70.1 in) Application Classification Class A Connector T4 series or H4 UTX or MC4-EV02 Power Tolerance 0-+10W Per Pallet 30 pieces *Under Standard Test Conditions(STC)of irradiance of 1000 W/mg,spectrum AM 1.5 and cell temperature of 25=c. Per Container(40'HQ) 660 pieces *A jacent two modules(portrait:left and right modules,landscape.up an own modules)need to be rotated 180 degrees. **Need to confirm with the tracker suppliers there are no mounting or operation risks when cables go across the torque tube and bearing house. ELECTRICAL DATA I NMOT* CS1U 40OMS 405MS 41OMS 415MS 420MS Nominal Max.Power(Pmax) 296 W 300 W 304 W 307 W 311 W TEMPERATURE CHARACTERISTICS Opt.Operating Voltage(Vmp)40.8 V 41.0 V 41.2 V 41.4 V 41.5 V Specification Data Opt.Operating Current(Imp)7.26 A 7.32 A 7.37 A 7.43 A 7.48 A Temperature Coefficient(Pmax) -0.37%/°C Open Circuit Voltage(Voc) 49.9 V 50.0 V 50.1 V 50.2 V 50.3 V Temperature Coefficient(Voc) -0.290 / C%/o C Short Circuit Current(Isc) 7.75 A 7.79 A 7.83 A 7.87 A 7.91 A Temperature Coefficient(Isc) 0.05 /o *Under Nominal Module Operating Temperature(NMOT),irradiance of 800 w/m,spectrum Nominal Module Operating Temperature 43±3*C AM 1.5,ambient temperature 20°C,wind speed 1 m/s. PARTNER SECTION ...................................................................................................................... The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going Innovation and product enhancement.Canadian Solar Inc. reserves the right to make necessary adjustment to the Information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and Installation instructions before using our PV modules. ....................................................................................................................: ................................................................................................................................................................................................................................................................. CANADIAN SOLAR INC. 545 Speedvale Avenue West,Guelph,Ontario N1 K 1 E6,Canada,www.canadiansolar.com,support@canadiansolar.com May 2020.All rights reserved,PV Module Product Datasheet V5.59 EN ENPHASE. ENPHASEm WA JIM IQ8 and IQ8+ Microinverters Easy to install Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter Power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability • Produce power even when the 0; T � Enphase grid is down" I More than one million cumulative hours of testing year limited 1. • Class II double-insulated Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- powered PV modules and analysis software. leading limited warranty of up to 25 years. Microgrid-forming • Complies with the latest advanced grid support" CERTIFIED Remote automatic updates for SAFETY the latest grid requirements Connect PV modules quickly and easily to IQ8 Series IQ8 Series Microinverters are UL Listed as Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range Of grid profiles manufacturer's Instructions. Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other •Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. ••IQ8 and IQ8PIus supports split phase,240V IQ8SP-DS-0002-01-EN-US-2022-03-17 installations only. �J IQ8 and IQ8+ Microinverters INPUT 1ATA(OCI 108-60-2-US1:' Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 j Max input DC voltage V 50 60 Max DC currentz[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT 1A 1: .1 1:• Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range3 V 240/211-264 I Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A(L-L)branch circuit" 16 13 i Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging I Peak efficiency A 97.5 97.6 i CEC weighted efficiency / 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range 4000 to+600C(-40OF to+1400F) i I� Relative humidity range 4%to 100%(condensing) DC Connector type MC4 - Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 302 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure I Environ.category/UV exposure rating NEMA Type 6/outdoor 1 CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 I Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to 1 manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 1O8SP-DS-0002-01-EN-US-2022-03-17