Loading...
HomeMy WebLinkAbout48628-Z PA Town of Southold 6/17/2023 P.O.Box 1179 53095 Main Rd y # {1r Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44179 Date: 6/17/2023 1 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 290 Grigonis Path, Southold SCTM#: 473889 Sec/Block/Lot: 70.-3-9 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/21/2022 pursuant to which Building Permit No. 48628 dated 12/20/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as aapplied for.. The certificate is issued to Nani,Michael&Laura of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48628 5/22/2023 PLUMBERS CERTIFICATION DATED A ho ze Signature �o�gUfF01 TOWN OF SOUTHOLD ay BUILDING DEPARTMENT x TOWN CLERK'S OFFICE ce SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 48628 Date: 12/20/2022 Permission is hereby granted to: Nani, Michael 290 Grigonis Path Southold, NY 11971 To: Install roof mount solar at existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled and readily accessible. At premises located at: 290 Grigonis Path, Southold SCTM #473889 Sec/Block/Lot# 70.-3-9 - Pursuant to application dated 10/21/2022 and approved by the Building Inspector. To expire on 6/20/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector ho��oF so�ryQl 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 Q Jamesh -southoldtownny.gov Southold,NY 11971-0959 �Q • �O couffm BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Michael Nani Address: 290 Grigonis Path city:Southold st: New York zip: 11971 Building Permit#: 48628 Section: 70 Block: 3 Lot: 9 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Trinity Solar Inc. Electrician: Richard Guaneri License No: ME-57843 SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel X A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect X Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 7.6kw roof mounted PV solar system with 21 panels and 1 solar edge s400 per modu 1 fused 60 amp disconnectwith 40 amp fuses and 1 inverter Notes: May 22, 2023 Inspector Signature: Date: 290 Grigonis path -1 V SO (p o� 6� lj r-t' V1 5 r� v i �o�aOF UIyo� # * TOWN OF SOUTHOLD BUILDI DEPT. `ycourm,��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION11 [ ] PRE C/O [ ] RENTAL REMARKS: L5 O LCL r2lm J— iL ll/n Jd' omdr-tl Rhouls r r, 16U4-a 90A-- r DATE INSPECTOR SO(/lh°� # # TOWN OF SOUTHOLD BUILDING DEPT. Co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 5a f 1Y✓ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 1 h DATE INSPECTOR ofso� $ 4.12 r , o ni # # TOWN OF SOUTHOLD BUILDING DEPT. `�cnurm e�' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ 'j ELECTRICAL (FINAL) [ ] CODE VIOLATIONf [ ] PRE C/O [ ] RENTAL REMARKS: ® ` ,� ®K 6olar eAav, 64on per rwAidt DATE 5, -C�19-�3 INSPECTOR ELD INSPECTION REPORT DATE COMMENTS t� FOUNDATION (1ST) N H ---------------------------------- C t1i FOUNDATION (2ND) -O ROUGH FRAMING& H J PLUMBING a r r� H INSULATION PER N.Y-- STATE :STATE ENERGY CODE yZt � L FINAL ADDITIONAL COMMENTS e 12 21 AOL a z ,� ce, p � � X H N Z x r� H x t4 b H 14,. �o�SeFFnt r�o TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 • o�> Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT 11L inn IF For Office Use Only OCT Z 1 .202 PERMIT N0. Building Inspector: ,I n Applications and forms must be filled out in their entirety. Incomplete ; applications will not,be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date:07/22/2022 OWNER(S)OF PROPERTY: Q Name:Michael Nani CIM#1000-07000-030 -009000 ProjectAddress�:290 Grigonls Path, M _._.__....._..... . _.. .,._NY 1.1971.__.._..._. Phone#:51,6-384-6901 .... .. Email:mnani@verizon..net . . __...__..__._...._._ _. Mailing Address^290 Grigonis_Path,.__._--...._w._... ._ .._. _ 119 . m.. ,...NY 71 _...... _._.. .. a. . . w CONTACT PERSON: S a ,Name:Brittany_ Gaum_er_­._._..._._._.___ .._._...____..__.__ ......_..........._ ...._._.._.__.__.__..._._..._.__.___... _._....._._... ____ _._.... ----._..... ..... ... MailingAddress:2180 5th Ave Unit 1. Ronkonkoma,v NY 11779 Phone#:631-319-7233 ____.._.. _.. .._.._ _.�.__...._ .. Emai!:Brittany_.Gaumer@trinity-solar_com DESIGN PROFESSIONAL INFORMATION: Name:lhor BOjCun._.....__..... _....._...__.___-_- ....__...._._-. MailingAddress:105Waypoint Drive, Eatontown,--NY 07724 Phone#:63.1-319-7233-_ .___. ..._._ . . _-._ Fail:lhOr.Bojcun@trinity solarsystems.com CONTRACTOR INFORMATION: Name:S,a.m_uel.MagIiaro.........._.__.__.___..............____.... .... ... .. __.__.._._ _..._. _. . ._.__._....._... ....____.. __. __ ._. ._. . __ ng Address: 2180... ......_.__._.___2.180„5th. Ave_Un_it_1 ,__Ronkon.koma,__..___ .._11779 Phone#:631-319-7233 _ _. .. Email:Brittany.Gaumer@trinity-solar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ©Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOtherSolar Panels $25,088.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? Eyes No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. B Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print me):S a m u e I M ag l i a ro ®Authorized Agent ❑Owner Signature of Applicant: Date: 07/22/2022 STATE OF NEW YORK) SS: COUNTY :� �\ �� �;C�o _being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing conntraact\ above named, (S)he is the 9 &c, (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 202 otary Public l3fil i MANY GAUMER NOTARY PUBLIC,STATE OF NEW YOR PROPERTY OWNER AUTHORIZATION NO. 01GA6428115 QUALIFIED IN SUFFOLK COUNTY (Where the applicant is not the owner) MY COMMISSION EXPIRES JAN 10,202 ,, Michael Nani residingat290 Grigonis Path Southold, NY do hereby authorize Samuel Magliaro to apply on my behalf to the Town of Southold Building Department for approval as described herein. '2/ntll. I p J I-a,�- Owner's Signature Date Michael Nani _ Print Owner's Name 2 .... FQj .. BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 o1,F Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roc err cDsoutholdtownny.gov seand@southoldtownny,gov APP.LICATI.ON FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 07/22/2022 Company Name: Trinity Solar Inc. Name: Richared Guaneri License No.: ME-57843 email: Rich.Guaneri@trinitysolarsystems.com Address: 2180 5th Ave Unit 1,Ronkonkoma,NY 11779 Phone No.:631-319-7233 JOB SITE INFORMATION (All Information Required) Name: Michael Nani Address: 290 Grigonis Path,Southold,NY 11971 Cross Street: Phone No.: 516-384-6901 Bldg.Permit#: email: mnani@verizon.net Tax Map District: 1000 Section: 070.00 Block:03.00 Lot:oo9.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of a utility approved,grid inter-tied,flush mount,roof mounted,19 Hanwha 400 solar panels,TRW photo voltaic electricity generating system. Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES /©O Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Vp. 0 P/"-a � 0 Request for Inspection Formals l ® DATE(MM/DD/YYYY) A�o CERTIFICATE OF LIABILITY INSURANCE 5/13/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder iS an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Mark Grasela Arthur J. Gallagher Risk Management Services, Inc, PHONE FAX 4000 Midlantic Drive Suite 200 Arc No Ext:856-482-9900 a/c No:856-482-1888 Mount Laurel NJ 08054 AODRLEss: CherryHill.BSD.CertM@AJG.com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Gotham Insurance Company 25569 INSURED TRINHEA-03 INSURER B:National Union Fire Insurance Company of Pittsburg19445 Trinity Solar Inc. 2180 Fifth Avenue, Unit 1A INSURER C:Liberty International Underwriters Ronkonkoma, NY 11779 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:1248340122 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDLSUBRTYPE OF INSURANCE INSD WVD POLICY NUMBER POLICY EFF MM/DD//YYYY LIMITS ICY EXP LTR A X COMMERCIAL GENERAL LIABILITY GL202100013378 6/1/2021 6/1/2023 EACH OCCURRENCE $2,000,000 DAMAGE TO RENTED CLAIMS-MADE X OCCUR PREMISES Ea occurrence $100,000 MED EXP(Any one person) $5,000 PERSONAL&ADV INJURY $1,000,000 GENT AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY JECT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ B AUTOMOBILE LIABILITY CA 2960145 6/1/2022 6/1/2023 COMBINED SINGLE LIMIT $2,000,000 Ea accident X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident $ A UMBRELLA LAB X OCCUR EX202100001871 6/1/2021 6/1/2023 EACH OCCURRENCE $5,000,000 C X EXCESS LIAB ELD30006989101 6/1/2022 6/1/2023 CLAIMS-MADE 1000231834-06 6/1/2022 6/1/2023 AGGREGATE $5,000,000 DED RETENTION$ Limit x of$5,000,000 $19,000,000 B WORKERS COMPENSATION WC 13588108 6/1/2022 6/1/2023 X PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE I ER ANYPROPRIETOR/PARTNER/EXECUTIVE ❑ NIA E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,descnbe under DESCRIPTION OF OPERATIONS below I E.L.DISEASE-POLICY LIMIT $1,000,000 B Automobile CA 2960145 6/1/2022 6/1/2023 All Other Units $250/500 Comp/Collusion Ded, Truck-Tractors and Semi-Trailers $250/500 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Route 25 AUTHORIZED REPRESENTATIVE Southold NY 11971 ,. A ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD NEw workers'STATE Compensation CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured TRINITY SOLAR INC. Contractor ID 612990 2180 FIFTH AVENUE, UNIT 1A 631-319-7233 RONKONKOMA, NY 11779 Work Location of Insured(Only required if coverage is specifically limited to 1c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 22-3292324 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Standard Security Life Insurance Company of New York Town of Southold 3b.Policy Number of Entity Listed in Box 1 a 54.375 Route 25 R71757-000 Southold,NY 11971 3c.Policy Effective Period 7/1/2013 to 6/1/2023 4. Policy provides the following benefits: ❑X A.Both disability and Paid Family Leave benefits. ❑ B.Disability benefits only. ❑ C.Paid Family Leave benefits only. 5. Policy covers: Q A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as descr' d above. Date Signed 6/2/2022 By Q. (Signature of insurance carrier's authoriled representative or NYS licensed insurance agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT:lf Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 46,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 46,4C or 513 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers' Compensation Board, the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) II I1111 ( 1111111 Workers' YORK CERTIFICATE OF sTATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Trinity Solar Inc. 631-319-7233 2180 Fifth Avenue,Unit 1A 1 c.NYS Unemployment Insurance Employer Registration Number of Ronkonkoma,NY 11779 Insured 49-230977 Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 22-3292324 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) National Union Fire Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"1a" 54375 Route 25 WC 013588108 Southold,NY 11971 3c.Policy effective period 6/1/2022 to 6/1/2023 3d.The Proprietor,Partners or Executive Officers are ❑ included.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3" insures the business referenced above in box 1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Michael Price (Print name of aauthodzed representative or licensed agent of insurance carrier) Approved by: �� ip2GC� 6/1/2022 (Signature) (Date) Title: C.E.O.North America Telephone Number of authorized representative or licensed agent of insurance carrier: Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name WILLIAM F CONDIT "per Business Name This certifies that the Trinity Solar Inc Dearer is duly licensed Dy the County of suffolk License Number:H-52821 Rosalie Drago Issued: 01/29/2014 Commissioner Expires: 01/01/2024 / Suffolk County Dept.of Labor,Licensing&Consumer Affairs MASTER ELECTRICAL LICENSE Name RICHARD GUANERI This Business Name S Corlifgg that the bearer is duly licensed Trinity Solar Inc. by the County of suffolk License Number:ME-57843 Rosalie Drago Issued: 12/15/2016 Commissioner Expires: 12/01/2022 APM® ED AS NOTED DATE:o?a0•: � g P# /o�� OCCUPANCY OR FEE D.DD BY: USE IS UNLAWFUL NOTIFY BUILDING DEPARTMENT AT WITHOUT CERTIFICATE 631-765-1802 8AM TO 4PM FOR THE OCCUPANCY OC OC FOLLOWING INSPECTIONS: f C 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE cc)l"IDLY W!,f-H ALL COD'ES OF REQUIREMENTS OF THE CODES OF NEW F�f? `�1 YOR� STATE & TOWN CODES YORK STATE. NOT RESPONSIBLE FOR AS IIEQUI ED AND CONDITIONS OF DESIGN OR CONSTRUCTON ERRORS SOUTHOLD TOWN ZBA - SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES N.Y S.DEC l�erngoKrlgq�oN RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. SOLAR Southold Town, NY July 13, 2022 Town Hall Annex Building54375 Route 25 P.O. Box 1179 Southold, NY 11971 RE: MICHAEL NANI; LAURA NANI Trinity Solar No. 290 Grigonis Path 2022-05-711353 Southold, NY 11971 To the Building Official: The following information constitutes a summary of the relevant design criteria and recommendations for the support of a new photovoltaic[PV] system on the existing roof framing components at the above-referenced location. Criteria is as follows: 1. Existing roof framing: Conventional roof framing is 2x6 at 24 o.c.; existing rafter span= 8' 0"; (horizontal projection) 2. Roof Loading: • 3.Opsf dead load (pounds per square foot- PV panels, mounting rails & hardware) • 5.7psf- existing roof loads (1.7psf-2x6 framing, 1.5psf roof sheathing, 2.5psf shingles) • Ground Snow Load- 20psf- per AHJ (Authority Having Jurisdiction) • Wind criteria- Exposure Category B, 128mph wind 3. Existing Roof modification - none required; existing roof framing is acceptable for PV installation. The installation, described above, is in general conformance with the manufacturers'specifications and complies with all applicable laws, codes, and ordinances as specified by applicable codes, including the 2020 Residential Code of New York State. The spacing of the mounting brackets cannot exceed a maximum of 48"o.c. between mounting brackets and will be fastened using 5/16"diameter corrosive-resistant steel lag bolts. In order to evenly distribute the load across the roof rafters, there shall be a minimum of 2 mounting brackets per rafter(4" long lag bolts required)and a minimum 2'/2" penetration (embedment)of all bracket lag bolts beyond the roofing materials; this is adequate to resist all stated live loads above— including wind shear. Per NDS Section 12.1.4, pilot holes not to exceed one-half the diameter of the shank need to be bored into the primary framing members for the full length of the threaded portion of the screw to avoid splitting of the framing member. Stainless steel lag bolts are required. Regards, Thor Bojcun, PE CF NE Structural Engineer-Trinity Solar t��CHAEC `.O z �- (P ( u �<) 095675 R�FESSIM4 NY License No.095675 Trinity Solar 12180 5th Avenue, Unit 1 1 Ronkonkoma,NY 1(631)319-7233 N ®o® EcoFasten, For Installers. By Installers. -- v� COMPLETE RAIL-BASED RACKING SYSTEM ClickFit is one of the fastest installing rail-based systems in the industry. Thanks to its Click-In rail assembly, the Composition Shingle, ®� Tile,Metal rails can be connected to any of EcoFasten's composition shingle,tile, and metal roof mounts in seconds without the need for fasteners or tools. The ClickFit system is made of robust materials such as aluminum and coated :::: Rail-Based steel,to ensure corrosion-resistance and longevity. ClickFit conforms to UL 2703 and has been tested in extreme weather conditions including wind,fire,and snow. FEATURES & BENEFITS Structural-Attach Direct-Attach • Tookless,fastener-free rail attachment • Fully integrated bonding • Click-On Mid &End Clamps • Compatible with a variety of EcoFasten roof attachments SU HUN i25 YEAR WARRANTY FAST INSTALLING SYSTEM FEATURING o6� CLICK-IN RAIL ASSEMBLY INTERNAL SPLICE Tool-free bonded internal Splice installs in seconds. MLPE MOUNT Attach Module Level Power MID CLAMP Electronics to the top of the rail. Click-on mid clamp features integrated bonding pins and fits modules 30-50 mm in width. END CLAMP Click-on end clamp fits modules END C A P 30-50mm in width. The slide-on end caps allow the end clamps to be accurately positioned on the rail in seconds, while providing an aesthetically- pleasing, finished install. 0 L- FOOT The ClickFit rail simply clicks ' into our proprietary composition shingle & the L-foot without the need to use fasteners or tools. W, - COMPOSITION SHINGLE, Combine the versatile ClickFit L-Foot with the watertight GF-1 flashing for a fast installation on composition shingle roofs. GF-1 FLASHING&L-FOOT TILE ROOFS Use the adjustable ClickFit Tile Hook for attaching the ClickFit system to tile roofs. Works with Flat, S, and W tile profiles. CLICKFIT TILE HOOK STANDING SEAM METAL ROOFS Combine the ClickFit L-Foot with SimpleBlockO-U for a fast installation on standing seam metal roofs. SIMPLEBLOCK-1.1 ECOFASTENSOLAR.COM S PRODUCT PART �, PART I' BOX PALLET IMAGE NUMBER t; DESCRIPTION I- QUANTITY �' QUANTITY 1 BONDEDASSEMBLED WITH(1)OF OROMMET AND INCLUDES(1)5/16"EPOM WASHER - GF1M-GAL-BLK-810 UV 8X10"BLK GLV 50 3200 W/2"HL PLCMT - GFT GAL BLK 812 GF1 8X12"GALVALUME BLK 50 2600 FLASHING HARDWAREALL 1 1 11 Ir 1500004 CF L-FOOT ASSY 100 5000 (NO HARDWARE NEEDED) 1500005 CF TILE HOOK US 20 480 1510045 CF TILE HOOK SUB-FLASHING 20 2160 TILE HOOK FLSH-F ST TILE HOOK FLASH 12 576 FLAT SIERRA TAN TILE HOOK FLSH-W ST TILE HOOK FLASH 12 575 W SIERRA TAN TILE HOOK FLSH-S ST TILE HOOK FLASH 12 576 S SIERRA TAN SIMPLEBLOCK-U-AL 2"SIMPLEBLOCK SSR-AL 25 4400 HARDWAREALL 1 1O 1500004 CFL-FOOTASSY 50 5000 (NO HARDWARE NEEDED] i �P 1500033 CF RAIL 2130MM N/A 108 (-7 FT) 1500034 CF RAIL 3166MM N/A 108 (-10.4 FT) 1500035 CF RAIL 4202MM N/A 108 (-13.8 FT] f 1008051 CF RAIL SPLICE 100 3200 1510070 CF WIRE MGMT CLIP 1000 TBD 1' 1500028 MODULE JUMPER,8 IN 25 25000 (204MMI > 1510057 CF MLPE MOUNT 400 17600 A• t r ' PRODUCT �' PART PART BOX PALLET IMAGE NUMBER I DESCRIPTION ; QUANTITY 1• QUANTITY 1510041 CF ENDCAP,BLK LABELED 100 4800 1510015 OF30MMOB KMP 20 5600 1510016 DF 3PMMDBLKMP 50 5600 1510017 CF HD ENOCLAMP 50 5600 35MM,BLK 1510018 CF HO ENOCLAMP 50 5600 38MM,BLK 1510019 CF HO 40MM,BLK MP 50 5600 1510020 CF HO ENOCLAMP 50 5600 45MM,BLK 1510011 CF HO MIDCLAMP 50 5600 30-40MM,BLK 1510012 CF HO MIOCLAMP 50 5600 40-50MM,BLK qppppop ROCK-IT V3 SKIRT A55 35MM RM& SKIRT V3 B 256 &40MM 65" ROCK-IT V3 SKIRT A79 ROCK-IT SKIRT 79 B 256 35MM&40MM 79" ROCK-IT V3 SKIRT A80 ROCK-IT SKIRT V3 8 256 35MM&40MM 80" ROCK-IT V3 SKIRT B65 ROCK-IT SKIRT V3 8 256 32MM&38MM 65" ROCK-IT V3 SKIRT 879 ROCK-IT SKIRT 79 8 256 32MM&38MM 79" ROCK-IT V3 SKIRT BBO ROCK-IT SKIRT V3 8 256 32MM&38MM 80 1500003 CF UNIVERSAL SKIRT 50 5750 CLAMP BLK POLY KIT LAG SCREW 4 POLY KIT LAG 50 480 SCREW 4"(50) SCRW OP 15-13X03 ROOFING SCRW 1000 60000 #15 X 3"DRILL PT u BOLT AND 1510001 CONDUITMOUNT-BRKT 50 10350 Lu INCLUDES li p CONOUITMOUNT-TILE CONDUIT MOUNT-TILE SYSTEM 60 4320 t' ii .�- Y. Oki 'a'' OO _ _ - %'', 'f' c -J�'� ,�'�(_ -'"' ,•fir' ,C•.,. I ME r-' ..EH.,`ti4'M: •.I. :'�'Y,:-' �,xq.""`-a:o-•=-ts;•.'Li.a-j;`;. _ y,,:;�, 8�..« - �� � cY s.+'.-+ 8 ""i'�'"v��, YJ�_7i-.xE'�yJO� ,- .' t•a..'„g�.4�. '� iF�" wi _:.Z� •-l'��n V.• t J+ '�' � 3a' s'�s' �.rv•�3 'til' :�; .+' ECOFASYEN SOLAR EcoFasten has an established a reputation for being one of the industry's leading innovators by providing expert solutions for mounting solar PV on any type of roof. Our broad portfolio of solutions stem from the needs of, and direct inputs by solar PV installers. We take pride in providing the right solution for every application. We educate our customers, so they purchase the best, most cost-effective solutions to fit their needs, and we complement that with on- site installation training to ensure 100% satisfaction. We are honest with ourselves, our customers, and our employees, fostering a culture of idea-sharing, innovation, and creativity. t n�'1 EcoFasten 4141 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009 I An ESDEC Company 1 - 877 - 859 - 3947 1 INF0@EC0FASTENS0LAR.00M I Single Phase Inverter Z with HD-Wave Technolog- C v m for North America X SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / Mmi SE760OH-US / SE10000H-US / SE1140OH-US m i • � f i O solar3',�[' ..�'i^woo ©`. �O .solar,3.GZ" A Optimized installation with HD-wave technology / Specifically designed to work with / UL1741 SA certified,for CPUC Rule 21 grid compliance power optimizers / Record-breaking efficiency / Extremely small / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article / Optional: Revenue grade data,ANSI C12.20 690.11 and 690.12 Class 0.5 (0.5%accuracy) solaredge.com solar ® ® ® z / Sin le Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.4" Hz Maximum Continuous Output 12.S 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output 16 - 24 - - 48.5 A Current @208V Power Factor 1,adjustable-0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 1 11800 1 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240Vt I 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V't - 9 13.5 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency gg 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption <2.5 W "'For other regional settings please contact SolarEdge support W A higher current source may be used;the inverter will limit its input current to the values stated t ® Single Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optionalt3' Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi Access Point for local connection Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL16998,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG T'Maximum/14-6 AWG 1"Maximum/14-4 AWG Range DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ (HxWxD) mm Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 Ib/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+601=1 Protection Rating NEMA 4X(Inverter with Safety Switch) 131 Revenue grade inverter P/N:SExxxxH-US0008NC4 01 Full power up to at least SO'C/122'F;for power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf ®SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Ro H S other trademarks mentioned herein are trademarks of their respective owners.Date,5/Z019N01/ENG NAM.Subject to change without notice. powered by DUO �YR Q TOP BRAND PV-,l 1 EUROPE Warranty Q CELLS °mJuct6Pedoimanc= Yield Secunty BREAKING THE 20%EFFICIENCY BARRIER /ren!I Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of v� the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behavior. _ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect and Traceable Quality Tra.QTMt. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400Pa)and wind loads(4000Pa). A RELIABLE INVESTMENT VAY Inclusive 25-year product warranty and 25-year linear performance warranty2. 'APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: (10 Rooftop arrays residential buildings Engineered in Germany CELLS MECHANICAL SPECIFICATION Format 74.0inx41.linx1.26in(including frame) (1879 mm x 1045 m m x 32 mm) 74°'(1879 mm) 5.6'(3955 mm) 42.8'(1088 mm) Weight 48.5lbs(22.0kg) Front Cover 0.13in(3.2mm)thermally pre-stressed glass with 3 :49.r(swmml } anti-reflection technology 0.0IaM6g poMu m 0]8'(4.6 1m1 R.- Back Cover Composite film 39.]'i996mm1 Frame Black anodized aluminum ® 41.1•ryo4smml Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes bB1� z49.T(13Wmm) Cable 4mm2 Solar cable;(+)2-49.2in(1250mm),(-)2_49.21n(1250mm) 6� fi.omne9enae, b 4.1V M 9slme(DE A) Connector Slaubli MC4;IP68 +� LZfi'(3Z mm1 DETAILA 063'(18mm) 0.96-(245mm1 OT0.33'(85mm1 ELECTRICAL CHARACTERISTICS 1 POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/-OW) Power at MPP1 PMpp [W] 385 390 395 400 405 Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 Open Circuit Voltage' Voc [V] 45.19 45.23 45.27 45.30 45.34 .5 Current at MPP Ivpp [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VvpP [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' rl [%] 2_19.6 2_19.9 2:20.1 x20.4 2_20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' Power at MPP pvpP [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current ISc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Voc [V] 42.62 42.65 42.69 42.72 42.76 'c Current at MPP INpp [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP Vvl`P [V] 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances PMpp±3%;Isc:Voc t5%at STC:1000 W/m2,25±2°C,AM 1.5 according to IEC 60904-3.2800 W/m2,N MOT,spectrum AM 1.5 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE \Loo 0 c:. - -_- At least 98%of nominal power during -• first year.Thereafter max.0.5% z I i 0w w �0 xm ...-- degradation per year.At least 93.5% 5100 -------- ______�__ --- -'--- th W a --------- _._ of nominal power up to 10 years.At Power u P z least 86%of nominal to a0 e° - 90 ----I a ' - -- ---- - 25 years. I-----7------ z - ---------- cz 5 o o All data within measurement toleranc- ' es.Full wart MISS in accordance with °0 900 400 60o e6o moo a the warranty terms of the Q CELLS o eo sales organisation of your respective IpgADIANCE[W/mr7 ., 0 V xm xe Country. - YEARS Typical module performance under low irradiance conditions in o ""°- ""`"�"'°""`0t'"`"`"•`-'0--` comparison to STC conditions(25°C,1000W/m2) M TEMPERATURE COEFFICIENTS o c? Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of VDD p [%/K] -0.27 � Temperature Coefficient of PMpp y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) 0 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage V_ [V] 1000(IEC)/1000(UL) PV module classification Class II o H Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 J W Max.Design Load,Push/Pull' [lbs/ft'] 75(3600Pa)/55(2660 Pa) Permitted Module Temperature -40'F up to+185mF a Max.Test Load,Push/PU113 (lbs/ft'] 113(5400Pa)/84(4000Pa) on Continuous Duty (-40°C up to+85°C) o 3See Installation Manual U QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION - UL 61730,CE-compliant, 0 IAV 6T Quality Controlled PV-TUV Rheinland, 00 0-1 IaO,HCI IEC 61215'2016,IEC 61730:2016, �® ♦ ♦ L U.S.Patent No.9,893,215(soler cells), /` (`� uv66emi,�a, Horizontal 76.4in 43.3in 48.Oin 16561bs 24 24 32 - QCPVCertification ongoing. CcmrzinmaUS packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules _ UL 61730 10 1111319x)7 U n w Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved Installation and use of this product. Hanwha 0 CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1949 748 59 96 1 EMAIL inquiryQus.q-cells.com I WEB www.q-cells.us NOTES: 1.)COMPLIES WITH NEC 2017 ' 2.)REFER TO SHEET PV-3 FOR SITE SPECIFIC VALUES REQUIRED BY NEC 690 3.)STICKERS,LABELS,AND PLACKARDS SHALL BE OF SUFFICIENT DURRABILITY TO WITHSTAND THE ENVIROMENT INVOLVED itv To be located on all DCj unction boxes SOUR Py SYSTEM EQUIPPED and every 30'on DC conduit YIITFI RAPID SNUNOWN SOLAR NEC 690.31(G) •"" 6 u NEC 690.56(C)(1)(A) DC)unction Box � '• • • • • M�,--4S' s• 690.56(C)13) ! ! NEC 690.4(B) Elm Aay,��� Service Disconnect NEC 690.13(9) NEC 690.53 R1T—\. 690.56(Q(3) Soladeck ® • • • SOURP4PID SH EDUtility WITH RAPI05HUTDOWNOWN ! ! ! NEC 690.4(8) ' NEC 690.13(8) •NEC 690.56(Q(1)(A) IfSystem isBackfedBreaker NEC 690.54 �� NEC 690.53 NEC® DC Disconnect NEC 690.54cy Utility Meter x_ .�ga Socket �,u t NEC 690.13(8) 16 �« NEC 690.54 { NEC 690.13(0) l G DC Condult Main Service Panel Solar Meter Socket Photovoltaic Load Center Inverter(s) Enphase Envoy Box AC Disconnect (To Combine Inverters) INSTALLATION O NEW GR'G°N'S PAT"' ROOF MOUNTED PV SOLAR SYSTEMF,- 3 � r HA d rte• , Q �� 290 G R I GO N I S PATH Y`.� °� P *. S J SOUTHOLD NY 11971 �j Issued/Revisions •v - R1CITY 7/18/2022 F011 ISSUED TO TOWNSHIP FOR PERMIT ]/./2022DESCRIPTION DATEVICINITY MAP SITE SCALE. NTS Project Title: MICHAEL NANI;LAURA NANI TRINITY ACCT#:2022-05-711353 Project Address: 290 GRIGONIS PATH SOUTHOLD,NY 11971 41.059910,-72.428892 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX Drawing Title: 1. THE INSTALLATION CONTRACTOR IS 8. THE DC VOLTAGE FROM THE PANELS IS 14. B) CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC COMPANY SPECIFICATIONS, kCMIL THOUSAND CIRCULAR MILS EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS kVA KILO-VOLTAMPERE PV-2 ROOF PLAN W/ MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILO-WATT CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND L LINE 2. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.ONCE APPROVED,THE MCB MAIN CIRCUIT BREAKER AP APPENDIX Drawing Information RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE INSTALLATION CONTRACTOR IS MDP MAIN DISTRIBUTION PANEL EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE RESPONSIBLE FOR INSTALLING ALL MLO MAIN LUG ONLY DRAWING DATE: 7/8/2022 DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. SYSTEM COMPONENTS AS DESCRIBED IN MTD MOUNTED DRAWN BY: MS IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR THE DRAWING PACKAGE. MTG MOUNTING N NEUTRAL REVISED BY: DMR 3. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE 16 ALL INFORMATION SHOWN MUST BE NEC NATIONAL ELECTRICAL CODE RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CERTIFIED PRIOR TO USE FOR NIC NOT IN CONTRACT UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE CONSTRUCTION ACTIVITIES. System Information: COMPONENT AND INVERTER MANUALS ARTICLE 690&705. NO# NUMBER PRIOR TO INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS NTS NOT TO SCALE DC SYSTEM SIZE: 7.6kW CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THEABBREVIATIONS OCP OVER CURRENT PROTECTION AC SYSTEM SIZE: 6kW ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL P POLE MODULE COUNT: 19 POSITION AND FUSES REMOVED PRIOR TO ATTEND A PRE-INSTALLTION MEETING AMP AMPERE PB PULL BOX THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AC ALTERNATING CURRENT PH 0 PHASE MODULES USED: HANWHA 400 SYSTEM COMPONENTS. PROCEDURES,SCHEDULES,SAFETY AND AL ALUMINUM PVC POLY-VINYL CHLORIDE CONDUIT MODULE SPEC#: O.PEAK DUO BLK ML-Gl0.a+400 POWER 4. ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. AF AMP.FRAME PWR POUTILITY COMPANY: PSEG-LI MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFF ABOVE FINISHED FLOOR QTY QUANTITY CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL AFG ABOVE FINISHED GRADE RGS RIGID GALVANIZED STEEL UTILITY ACCT#: 9650104826 ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL AWG AMERICAN WIRE GAUGE SN SOLID NEUTRAL UTILITY METER M 98359382 SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC WIRING C CONDUIT (GENERIC TERM OF JSWBD SWITCHBOARD DEAL TYPE: SUNNOVA COURSE ON SITE. CONDUCTIVITY CHECKS. RACEWAY,PROVIDE AS TYP TYPICAL 5. FOR SAFETY,IT IS RECOMMENDED THAT 12. FOR THE PROPER MAINTENANCE AND SPECIFIED) U.O.I. UNLESS OTHERWISE INDICATED THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CB COMBINER BOX XF WEATHERPROOF MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CKT CIRCUIT +72 TRANSFORMER Rev.No. Sheet TOGETHER AND THAT EACH OF THE OPERATION MANUAL. CT CURRENT TRANSFORMER +72 MOUNT 72 INCHES TO BOTTOM INSTALLATION CREW MEMBERS BE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC CU COPPER OF ABOVE FINISHED FLOOR OR IN FIRST AID AND CPR. AND TELEPHONE UTILITIES ARE SUBJECT DC DIRECT CURRENT GRADE �I �\, 6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF THE DISC DISCONNECT SWITCH 1 �/ BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND DWG DRAWING CONVENTIONS OF THE NATIONAL OWNERS. EC ELECTRICAL SYSTEM INSTALLER ELECTRICAL CODE. ANY LOCAL CODE 14. ALL MATERIALS,WORKMANSHIP AND EMT ELECTRICAL METALLIC TUBING WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION FOR THE SITE FS FUSIBLE SWITCH GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL FU FUSE 7. ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH: GND GROUND * ty(9) INSTALLED WITH THIS SYSTEM ARE TO BE A) CURRENT PREVAILING MUNICIPAL GFI GROUND FAULT INTERRUPTER "UL"LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, HZ FREQUENCY (CYCLES PER 3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS SECOND) GENERAL NOTES S01 AR IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT. 2211 Allenwood Road 877-786-7283 Wall,New Jersey07719 www.Trinity-Solar.com NOTES:'REFER TO MODULE SPECS FOR MODULE DIMENSIONS 'DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE ECOFASTEN CLAMP NEW PV SOLAR MODULE,TYPICAL (REFER TO SPEC SHEET FOR DETAILS) (REFER TO EQUIPMENT SCHEDULE FOR SPECS AND QUANTITIES) SOLAR MODULE SOLAR MODULE _ NEW MOUNTING FOOT/ATTACHMENT ♦ POINTS,TYPICAL (REFER TO ECOFASTEN"L"FOOT ECOFASTEN RAIL ,\\ ZZ5 2 / ENGINEERING LETTER FOR SPACING - Y (REFER TO SPEC SHEET FOR DETAILS) (REFER TO SPEC SHEET FOR CETAILS) C AND DETAILS) NEW ECOFASTEN RAIL,TYPICAL in G \t TO BE MOUNTED PERPINDICULAR TO EXISTING ASPHALT SHINGLES ECOFASTEN FLASHING A O STRUCTURE(REFER TO ECOFASTEN M3 ,�P �p�GHAQ (� SPECIFICATION 1 DATA SHEET FOR (REFER TO ENGINEERS LETTER FOR SPECS) (REFER TO SPEC SHEET FOR DETAILS) DETAILS) NEW END CLIP,TYPICAL S.S.LAG BOLT — APOC SEALANT 97 �♦ �♦ (REFER TO ECOFASTEN SPECIFICATION (REFER TO ENGINEERS LETTER FOR SPECS) SOLAR MODULES SHALL NOT ' /DATA SHEET FOR DETAILS) „ W EXISTING RAFTER EXCEED PEAK HEIGHT. � NEW MID CLIP,TYPICAL (REFER TO ENGINEERS LETTER FOR SPECS (REFER TO ECOFASTEN SPECIFICATION DATA SHEET FOR DETAILS) 0 nATTACHMENT&CLIP DETAIL PV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF 40 9p$675 tLJ SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE vrOF�ySiQ`t P\i ARRAY SCHEDULE Issued/Revisions i rl td BACK , R1 CIN 7/16/3033 UD AC P1 ISSOEDTO TOWNSHIP FOR PERMR 7/6/3033 l i NO. DESCRIPTION DATE 1�I► -- - Project Title: -11, - - MICHAEL NANI LAURA NANI - - 4 -- --- ` - --- 2-05-711353 • - 7 f--=- - -- - ' ' - ' - - -- ----' TRINITY ACCT it:202 Fp­­­ _ _ ____ __ ______ _ ___ _ _ - o1-7 Project Address l t --- -1: - - - - - - - -- - - - 290 GRIGONIS PATH SOUTHOLD,NY 11971 _ 41.059910,-72.428892 Drawing Title: PROPOSED PV SOLAR SYSTEM • Drawing Information 72, DRAWING DATE: 7/8/2022 DRAWN BY: MS REVISED BY: DMR • System Information: DC SYSTEM SIZE: 7.6kW AC SYSTEM SIZE: 6kW R4 R3 MODULE COUNT: 19 UD MODULES USED: HANWHA400 MODULE SPEC M Q.PEAK DUO BLK ML-G10.a+400 CM E UTILITY COMPANY: PSEG-LI UTILITY ACCT#: 9650104826 NOTES: UTILITY METER#: 98359382 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE DEAL TYPE: SUNNOVA WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. _ FRONT 2.)ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Rev.NO. Sheet AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S) NEC 690.13(E) . 5.) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 6.) ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. ^ w �` , ^ ROOF 1 SYMBOL LEGEND - PLUMBING SCHEDULE EQUIPMENT SCHEDULE K 1 V MODULES:19 QTY SPEC# PITCH:23 INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE INDICATES NEW PV ONLY SUBPANEL ORIENTATION:236 R1 ARRAY SCHEDULE FOR MORE INFORMATION UD INSTALLED OUTSIDE (UTILITY ACCESSIBLE) SP TO BE INSTALLED 19 HANWHA 400(Q.PEAK DUO BLK ML-G10.a+400) ROOF — MODULES:0 INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SE6000H-USOSHBNC4 PITCH:23' • • ORIENTATION:56° ( M ( INDICATES EXISTING METER LOCATION INDICATE PANELS THAT USE MICRO INVERTERS. pC INDICATES NEW DC DISCONNECT O ROOF 3 REFER TO EQUIPMENT SCHEDULE FOR SPECS. MODULES:0 OTHER OBSTRUCTIONS Trr 1. t PITCH:23' INDICATES EXISTING ELECTRICAL PANELINDICATES NEW PRODUCTION METER TO BE ORIENTATION:326° EP LOCATION: INSIDE n INSTALLED OUTSIDE. SD INDICATES EXISTING E:ERVICE DISCONNECT SOLAR OLA R MODULES:0 INDICATES NEW INVERTER TO BE PITCH:23' INDICATES NEW 0 TO BE INSTALLED ORIENTATION:146' OUTSIDE(UTILITY ACCESSIBLE) ® INSTALLED OUTSIDE. TS INDICATES EXISTING TRANSFER SWITCH 2211 Allenwood Road 877-756-7253 p• REFER TO EQUIPMENT SCHEDULE FOR SPECS Wall,New Jersey 07719 www.Trinity-Sclar.com Engineer/License Holder: ARRAY CIRCUIT WIRING NOTES 1. LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH SOLAR MODULES MOUNTED TO ROOF ON 1 ARRAY NEC 2017 19-400W MODULES EDGE S 1- 15 ADC MAX PER STRING 40 PER MODULE O 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON Q` \GH+QE(e ASHRAE MINIMUM MEAN EXTREME DRY BULB i STRINGg"xg" --------------------------------------------------------- TEMPERATURE FOR ASHRAE LOCATION MOSTSIMILARTO JUNCTION INSTALLATION LOCATION. LOWEST EXPECTEDAMBIENT 15TRININGOF9MODULESINSERIES-380 Vmax OF 10 MODULESINSERIES-380Vmax BOX I j.l1 TEMP=-16'C I •2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 I - 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASEDON ASHRAE HIGHEST MONTH 2%DRY BULB I TEMPERATURE FOR HRAELOCATONMOSTSIMILARTO _r A.�. Z i INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= I • 33°C �A 095675 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN SS STATES TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES(PALM SPRINGS,CA IS 44.1°C). FOR LESSTHAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED i Issued/Revisions SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING ' THE OUTDOOR DESIGN TEMPERATURE OF 47'C OR LESS (ALL OF UNITED STATES) I 5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS I R2 a1v 2/18/2022 SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I Pl ISSUED TO TOWNSHIP FOR PERMIT 7/8/2022 NEC 690.12(A)THROUGH(D) . `'p j NO. DESCRIPTION DATE 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC i Project Title: SOURCE AND OUTPUT CIRCUITAS PER NEC 690.41(A)(4) I MICHAEL NAN[;LAURA NAN[ 7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: ( TRI N ITY ACCT#:2022-05-711353 POSITIVE CONDUCTORS =RED NEGATIVE CONDUCTORS=BLACK NEC210.5(C)(2) I Project Address: I /f;F• I 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV EXISTING 240V -1� NOTE: WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE 1�120/240V O INTERNAL REVENUE GRADE MONITORING 290 GRIGONIS PATH ( 200A MAIN BREAKER PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT UTILITY METER CONTAINED WITHIN SOLAR EDGE INVERTER I SOUTHOLD,NY 11971 SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24"SHALL a i 200A BUSBAR SOLAR EDGE PN.RWND-3D-240-MB CONTAIN 55 20 CURRENT CARYING CONDUCTORS AND 41.0$9910,-72.428892 WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN 5_ 9 CURRENT CARRYING CONDUCTORS. I------- e= Drawing Title: 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS '£ OTHERWISE NOTED I 10.)FLEXIBLE CONDUITSHALL NOT BE INSTALLED ON I60A UNFUSED 60A UNFUSED PROPOSED PV SOLAR SYSTEM ROOFTOP AND SHALL BE LIMITED TO 12"IF USED DISCONNECT DISCONNECT OUTDOORS INVERTER#1 D zaoV 10 240V 10 Drawing Information 11.)OVERCURRENT PROTECTION FOR CONDUCTORS ISO a E oAm SOLA- AONE SOIL > CONNECTED TO THE SUPPLY SIDEOFASERVICESHALLBE -�_ ___ a+� I DRAWING DATE: 7/8/2022 LOCATED WITHIN 10'OFTHE POINT OF CONNECTION NEC LLL��JJI___ I DRAWN BY: MS 705.31 m m I I 1 �� > 0 I REVISED BY: DMR 12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE A n. I`�f" J UTILITY ANDTHE OTHER AN INVERTER,PV BACKFEED r--- ---_ m =e r____._. B - _- B - ��� _ E Ll L2 N 4 j System Information: BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY -- m m--- m m m m m m - - - -- m m m m m m 0 -----------� L I j DC SYSTEM SIZE: 7.6kW NEC 705.12(B)(2)(3)(b) �y I 13.)ALLSOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY EXISTING MAIN BREAKER LOAD SQUARED SQUARED � � vlt------J AC SYSTEM SIZE: 6kW CENTER DU222RB DU222RB L --------J MODULE COUNT: 19 GENERATION CIRCUITS AND NO UNUSED POSITIONS OR 2p40A BACK FEED BREAKER LOADS - NEC 705.12(B) MODULES USED: HANWHA 400 MODULE SPEC#: Q.PEAK DUO BLK ML-G10.a+400 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE UTILITY COMPANY: PSEG-LI A NEMA 3R RATING UTILITY ACR#: 9650104826 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY REQUIRE-CONDUCTOR AMPACITY PER STRING DEALTYPE: SUNNOVA (NEC 690.8(8)(1)1:(15.00.1.25)1=18.75A PV MODULE SPECIFICATIONS AWG#10,DERATED AMPACITY HANWHA 400(Q.PEAK DUO BLK ML-GlO.a+400) AMBIENTTEMP:33°C,TEMP DERATING FACTOR:.96 Rev.No. Sheet RACEWAY DERATING=4 CCC:0.80 Imp 10.77 NOTE:CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR (40".96)0.80=30.72A VEEP 37.13 TO MEET OR EXCEED NECAND LOCAL AHJD REQUIREMENTS R 1 PV 3 30.72A'_18.75A,THEREFORE WIRE SIZE IS VALID Voc 45.3 A #6THWN-2 GECTO EXISTING GROUND ROD TOTAL AC REQUIRED CONDUCTOR AMPACITY Isc 111.14 B 1"CONDUIT W/248 THWN-2.1410 THWN-2.1-#10 THWN-2 GROUND 25.o0A'1.25=31.25A C 1"CONDUIT W/4-#10 THWN-2,1410 THWN-2 GROUND AWG#8,DERATED AMPACITY INVERTER#1-SE600OH-USOSHBNC4 AMBIENTTEMP:30°C,TEMP DERATING:1.0 DC AC D 1"CONDUIT W/4-#10 THWN-2,1-#10 THWN-2 GROUND RACEWAY DERATING_3 CCC:N/A (amav(9) 55A'1.0=55A Imp 16.5 Pout 6000 E 1"CONDUITW/2-#BTHWN-2,1-#10THWN-2,1-#SOTHWN-2 GROUND SSA' VEEP 380 ]max 25 _31.25A,THEREFORE AC WIRE SIZE IS VALID F #10 PV WIRE(FREE AIR)W/#6 BARE COPPER BOND TO ARRAY CALCULATION FOR PV OVERCURRENT PROTECTION Voc 480 OCPDmin 31.25 TOTAL INVERTER CURRRENT:25.00A Isc 30 Vnom 240 G 1"CONDUIT W/2-#6THWN-2,1-#6THWN-2.148 THWN-2 GROUND SOLAR 25.00q"1.25=31.25A 2211 Allenwood Road 877-786-7283 -->40A OVERCURRENT PROTECTION 15 VALID Wall,New Jersey 07719 www.Trinity-Solar.com 1 r