HomeMy WebLinkAbout49523-Z TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
ISN!
SOUTHOLD, NY
' BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLAINS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 49523 Date: 7/27/2023
Permission is hereby granted to,-
3604
o:3604 Farm School Rd
Ottsville, PA 18942
To Install a 26KW generator to an existing single-family dwelling as applied for per
manufacturers specifications.
At premises located at:
1315 Mason Dr, Cutcho uc e
SCTM # 473889
Sec/Block/Lot# 104.-5-33.1
Pursuant to application dated 6/20/2023 and approved by the Building Inspector.
To expire on 1/25/2025
Fees:
ACCESSORY $100.00
CO-RESIDENTIAL $50.00
ELECTRIC $85.00
Total: $235.00
Building Inspector
n kr
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
, , # Telephone (631) 765-1802 Fax(631) 765-9502 litti)s:�//ww,,v..soutlioldtowiiny,go
Date Received
APPLICATION FOR BUILDING PERMIT
hm
For Office Use Only ° � 'J
PERMIT NO. 3 Building Inspectors
Applications and forms must be filled out in their entirety. Incomplete
applications will not be accepted. Where the Applicant is not the owner,an
Owner's Authorization form(Page 2)shall be completed.
Date:
OWNER(S)OF PROPERTY:
Name. SCTM#1000-
J �� — s— 33• /
Project Address:
Phone#: _ Email: ,
Mailing Address: cot e4,kes "L
CONTACT PERSON:
Name:
Mailing Address:
Phone#: Email:
DESIGN PROFESSIONAL INFORMATION:
Name:
Mailing Address:
Phone#: Email:
CONTRACTOR INFORMATION:
Name: 00 6 rJ- 1,414,
Mailing Address
v,
MailingAddress SIX 6A .o— � 3r
Phone#: Email:
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
U'Other
Lt.,, - $ 12 R
Will the lot be re-graded? ❑Yes El No Will excess fill be removed from premises? ❑Yes El No
1
PROPERTY INFORMATION
Existing use of property: Intended use of property:
Zone or use district in which premises is situated: Are there any covenants a d restrictions with respect to
this property? ❑Ye No IF YES, PROVIDE A COPY.
'Jheck Box After Reading. The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized Inspectors on premises and In building(s)for necessary Inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print me): Q�(� 13A thorized Agent ❑Owner
Signature of Applicant: w. _ � Date:
STATE OF NEW YORK)
S:
COUNTY OF ✓ v« )
& being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the 4fe-,>n '�rt Jo l-
(Contractor,Agent, Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
da of ,,Ke
Y ZQ
Notary Public
JOHN A.MAKI
Notary Public-State of New York
PROPERTY I ERTR) n No.01MA6164838
-w° .......... Qualified in Suffolk County
(Where the applicant is not the owner) My Commission Exp, 04/30/202.7
residing at Ls— " L
do hereby authorizeapply i1 to �
- ' on
my behalf to the Town of outhold Building Department for approval as described herein.
�
ne s Sig ure Date
Print Own rer s Name
2
BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
Town Hall Annex- 54375 Main Road - PO Box 1179
�y Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
ro err southoldtownn ov seand southoldtownnv,.,aov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (Ali Information Required) Date: 5/25/2023
Company Name: Peconic Power Systems
Electrician's Name: Robert Stanevich
License No.: ME-45056 Elec. email: econicpovwersys@gmail.com
Elec. Phone No: 516-819-7191 211 request an email copy of Certificate of Compliance
Elec. Address.: P.O Box 512 Cutchogue NY 11935
JOB SITE INFORMATION (All Information Required)
Name: Greqoey Krug
Address: 1315 Mason Drive Cutchoque NY,11935
Cross Street: Haywaters Drive
Phone No.: 216-718-5811
Bldg.Permit#: email:gkrug1 @1 ampire,com
Tax Map District: 1000 Section 10 Block: Lot: 33 0
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
26KW Generator
Square Foota e:
Circle All That Apply:
Is job ready for inspection?: 9 YES NO E]Rough In �✓ Final
Do you need a Temp Certificate?: 1:1 YES `/ NO Issued On
Temp Information: (All information required)
Service Size 01 Ph[]3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground[]Overhead
#Underground Laterals 1 M2 H Frame Pole Work done on Service? Y ON
Additional Information:
PAYMENT DUE WITH APPLICATION
roes # 0 3 - ,►o
LAMJ) NIf oF• ���. WHAL.&M,
Al 75°. oo�.
j AAD p
q
00
u r
W
14
SA
h •
5rae/`� 3s.s ca
o FtA,nE i .6rbA/ N
t4.. •lo
C 0
`C t N
^� iso•Cos
-MouS6 n P.ivc,
GENERAC®
GUARDIAN® SERI26 kW ES
Residential Standby Generators
Air-Cooled Gas Engine
Standby Power Rating
INCLUDES: G007290-0,G007291-0(Aluminum-Bisque)-26 kW 60 Hz
• True Power" Electrical Technology
• Two-line multilingual digital LCD Evolution"controller
(English/Spanish/French/Portuguese)
• 200 amp service rated transfer switch available
• Electronic governor = --
• Standard Wi-Fi®connectivity `~ �~
• System status&maintenance interval LED indicators
• Sound attenuated enclosure
• Flexible fuel line connector r� .
• Natural gas or LP gas operation , «' GENERAC
�-
• 5 Year limited warranty ;
• Base fascia
• Listed and labeled for installation as close as 18 in(457 mm)to a
structure.*
*Mustbe located awayfrom doors,windows,and fresh airintakes and in ON or C �L US Moesaccordance with local codes. cus LISTED QUIET—TEST ""y
Note:CETL or CUL certification only applies to unbundled units and units packaged
with limited circuit switches.Units packaged with the Smart Switch are EFL or UL
certified in the USA only.
r
FEATURES
O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod-
Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAxI-
the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge
rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%.
O TRUE POWER"' :ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network
form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small-
allows confident operation of sensitive electronic equipment and micro-chip based est electronic component.
appliances,such as variable speed HVAC systems.
O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with
✓ PROTOTYPE TESTED v NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC
✓ SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY product line Is offered with its own transfer systems and controls for total system
compatibility.
O MOBILE LINK°CONNECTIVITY:FREE with select Guardian Series Home standby
generators, Mobile Link Wi-Fi allows users to monitor generator status from any-
where in the world using a smartphone,tablet,or PC.Easily access information such
as the current operating status and maintenance alerts. Users can connect an
account to an authorized service dealer for fast,friendly,and proactive service.With
Mobile Link,users are taken care of before the next power outage.
GENERAC®
26 kW Features and Benefits
Engine
• Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly
rings help the engine run cooler,reducing oil consumption and resulting in longer engine life,
• "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance These features combine to assure smooth,quick starting every time.
• Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine
life.Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
• EPA Certified for non-emergency applications Allows unit to be used for demand response applications.
• High temperature shutdown Prevents damage due to overheating.
Generator
• Revolving field Allows fora smaller,light weight unit that operates 25%more efficiently than a revolving armature generator.
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability.
• Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes.
• UL 2200 listed For your safety.
'transfer Switch(if applicable)
• Fully automatic Transfers vital electrical loads to the energized source of power.
• NEMA 311 Can be installed inside or outside for maximum flexibility.
• Integrated load management technology Capability to manage additional loads for efficient power management.
• Remote mounting Mounts near an existing distribution panel for simple,low-cost installation,
Evolution'" Controls
• AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition,
• Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences.
• Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations.
• Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage.
• Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home.
• Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds.
• Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute.
• Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for
5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
• Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries.
• Main line circuit breaker Protects generator from overload.
• Electronic governor Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access
to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries.
• Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure.
GENERAC°
26 kW Features and Benefits
Installation Systema
• 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
• Integral sediment trap Meets IFGC and NFPA 54 installation requirements.
Connectivity(lrti'i-Fi equipped models only)
• Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for '
complete,peace of mind.
• Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.
• Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due,
• Monthly report with previous month's activity Detailed monthly reports provide historical generator information.
• Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.
• Weather information Provides detailed local ambient weather conditions for generator location.
,
GENERAC®
26 kW Specifications
Generator
Model G007290-0
G007291-0
(26 kW)
Rated maximum continuous power rapacity(LP) 26,000 Watts'
Rated maximum continuous power rapacity(NG) 22,500 Watts"
Rated voltage 240
Rated maximum continuous load current—240 volts(LP/NG) 108.3/93.8
of ' Total Harmonic Distortion Less than 5%
Main line circuit breaker 110 amp
Phase 1
Number of rotor poles 2
Rated AC frequency 60 Hz
Power factor 1.0
Battery requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum
Unit weight(Ib/kg) 518/235
Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x 73.7
Sound output in dB(A)at 231f(7 m)with generator operating at normal load"' 67
Sound output in dB(A)at 23 it(7 m)with generator in Quiet-Test"'low-speed exercise mode" 57
Exercise duration 5 min
Engine
Engine type GENERAC G-Force 1000 Series
Number of cylinders 2
Displacement 999 cc
Cylinder block Aluminum w/cast iron sleeve
Valve arrangement Overhead valve
Ignition system Solid-state w/magneto
Governor system Electronic
Compression ratio 9.5:1
Starter 12 VDC
Oil capacity including filter Approx.1.9 qt/1.8 L
Operating rpm 3,600
Fuel consumption
Natural gas W/hr(m'/hr) 188(5.32)
1/2 Load 3
Full Load 33(9.43)
Liquid propane ft3/hr(gal/hr)Mr] 75(2.06)[7.78]
1/2 Load
full Load 132(3.63)[13.73]
Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.
For BTU content,multiply ft3/hr x 2500(LP)or 0/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG).
Controls c
Two-line plain text multilingual LCD Simple user interface for ease of operation.
Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser.
MANUAL Start with starter control,unit stays on,If utility fails,transfer to load takes place.
OFF Stops unit.Power is removed.Control and charger still operate.
Ready to Run/Maintenance messages Standard
Engine run hours indication Standard
Programmable start delay between 2-1500 seconds Standard(programmable by dealer only)
Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V
Future Set Capable Exerciser/Exercise Set Error warning Standard
Run/Alarm/Maintenance logs 50 events each
Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration).
Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped.
Smart Battery Charger Standard
Charger Faull/Missing AC warning Standard
Low Battery/Battery Problem Protection and Battery Condition indication Standard
Automatic Voltage Regulation with Over and Under Voltage Protection Standard
Under-frequency/Overload/Stepper Overcurrent Protection Standard
Safety Fused/Fuse Problem Protection Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard
Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard
High Engine Temperature Shutdown Standard
Internal Faull/Incorrect Wiring protection Standard
Common external fault capability Standard
Field upgradable firmware Standard
Rating definitions—Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed.
No overload capability is available for this rating.(All ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271).Maximum kilovolt amps and current are subject to and limited by such factors as
fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level and approximately 1%
for each 10°F(6°C)above 60°F(16°C)."'Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.
U.S.EPA certified for non-emergency applications.
GENERAC'
26 kW Switch Options
Service Rated Automatic Transfer S1.Vitch Features Model G007291-0(26 kW)
• Intelligently manages up to four air conditioner loads with no additional hardware. No,of poles . 2
Current rating(amps) 200
• Up to eight additional large(240 VAC)loads can be managed when used in conjunction Voltage rating(VAC) 120/240,10
with Smart Management Modules(SMMs). Utility voltage monitor(fixed)*
• Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up 80%
-Dropout 65%
• Main breakers are rated for 80%continuous load. Return to Utility` Approx 13 sec
• 2-pole,250 VAC contactors. ETL or UL listed Standard
• Service equipment rated,dual coil design. Enclosure type NEMA/UL 3R
• Rated for both aluminum and copper conductors. Circuit breaker protected 22,000
Lug range 250 MCM-#6
• Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly
w�
Dimensions
200 Amps 120/240,1 e
Open Transition Service Rated
Height Width Depth
H1 H2 W1 W2 ": "'
in 26.8 30.1 i 10.5 1 13.5 6.9
cm 67.95 76.43 26.67 1 34.18 17.5
Wire Ranges
Conductor Lug Neutral Lug Ground Lug
250 MCM-#6 350 MCM-#6 2/0-#14
GENERAC"
26 kW Available Accessories
Model# Product Description
G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF(-18°C). (Not nec-
essary for use with AGM-style batteries).
G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0 IF(-18°C).
G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where
heavy icing occurs.
' G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be
Contact Kit needed.Not compatible with 50 amp pre-wired switches.
G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured
appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base.
G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion.
The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a
Generac automatic standby generator(oil not included).
G007005-0 WI-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the
Monitor LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta-
tus alerts are available through a free application to notify users when the LP tank is in need of a refill.
G007000-0(50 amp) Smart Management Module Smart Management Modules.(SMM)are used to optimize the performance of a standby generator.It manages large elec-
G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce
(100 amp) the overall size and cost of the system.
G007169-0-413 LTE Mobile Llnk°'Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere In the world,using
G007170-0-WI-Fl/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us-
Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,
users are taken care of before the next power outage.
G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured
appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base. Kit
contains four plugs,sufficient for use on a single air-cooled home standby generator.
Dimensions & UPCs
Model UPC 8376.. 1218 in]mm
[25.1 In]
G007290-0 696471087307 [48.0
G007291-0 696471087314
727.2 mm
[28.6 In]
O Q
648.. 1232 mm
[25.5 in] [48.5 IM
LEFT SIDE VIEW FRONT VIEW
Dimensions shown are approximate.See installation manual for enact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
GENE RAC' Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com
" �� ' M11 52022 Generac Power Systems,Inc. NI rights reserved. All specifications are subject to change without notice. Part No.A0002026894 Rev.G 04/26/2022