Loading...
HomeMy WebLinkAbout48597-Z OSS ICY Town of Southold 5/21/2023 P.O.Box 1179 oco _ .,� 53095 Main Rd y o�.".0 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44117 Date: 5/21/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1815 Bay Shore Rd, Greenport SCTM#: 473889 Sec/Block/Lot: 53.4-8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/14/2022 pursuant to which Building Permit No. 48597 dated 12/14/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing_single-family dwelling as applied for. The certificate is issued to Burton,Yvette&LaBarca,Patricia of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48597 2/15/2023 PLUMBERS CERTIFICATION DATED Auth rized gnature o�SUF o TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE CA "oy • SOUTHOLD, NY dol� yao�ti BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 48597 Date: 12/14/2022 Permission is hereby granted to: Burton, Yvette 400 Central Park W 15G New York, NY 10025 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 1815 Bay Shore Rd, Greenport SCTM #473889 Sec/Block/Lot# 53.4-8 Pursuant to application dated 10/14/2022 and approved by the Building Inspector. To expire on 6/14/2024. Fees: SOLAR PANELS $50.00 CO-ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $200.00 Building Inspector UeSo�,yo� 9 X59 �l spy Sk,,e # # TOWN OF SOUTHOLD BUILDING DEPT. `ycouHn��' 631-765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: n/a r DATE Z INSPECTOR OF SO//T�olo * # TOWN OF SOUTHOLD BUILDING DEPT. couxn,��'' 631-765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [FINAL 5®1,strc� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR pF SOUjyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlina-town.southold.nv.us Southold,NY 11971-0959 �yC4UNTl,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Yvette Burton Address: 1815 Bay Shore Rd city,Greenport st: NY zip: 11944 Building Permit#: 48597 Section: 53 Block: 4 Lot: 8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Long Island Power Solutions License No: 36178ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 7,665kW Roof Mounted Pv Solar Energy System w/ (21) Enphase QpeakBLKG10 365W Modules, Combiner Panel AC Disconnect Notes: Solar Inspector Signature: Date: February 15, 2023 .41 S.Devlin-Cert Electrical Compliance Form Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2Bmc Bohemia, NY 11716 Ph:631-988-0000 Gc solar@pacificoengineering.com February 13, 2023 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Patricia La Barca Section-Block-Lot: 1815 Bay Shore Rd Permit Num r: 48597 _a Greenport, NY 11944 1 have reviewed the solar energy system installation at the subject address on February 13,2023.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2020 Residential Code of New York State and ASCE 7-16. To my best belief and knowledge,the work in this document is accurate,conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer r(,V� Nlt yy Y �FQAR Ralph Pacici co, ssiioonal Engineer NY 0661821 NJ 24GE047443061 FL 87297 APR 2 5 2023 I omv CF r r)r MELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) 3 y -------------------------------- CA ---- � C FOUNDATION (2ND) m z � o C31 � ROUGH FRAMING& y PLUMBING Q19 INSULATION PER N.Y: y STATE ENERGY CODE Ole- /0"e- G'. o- FINAL i ADDITIONAL COMMENTS IILA-d eCa t ZZ a:5- _ uhf i nsfr- z - m M y O z x d b H :o�o�,�SUfFOttcoGy�4 TOWN OF SOUTHOLD—BUILDING DEPARTMENT h Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971- 0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only nD 12CZGV[E PBuilding Inspector: LM OCT 1 4 2022 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an BIDING DE PT. Owner's Authorization form(Page 2)shall be completed. TOWN OF StIIJ'i HOLD Date:October 10th, 2022 OWNER(S)OF PROPERTY: Name:Patricia Labarca ` SCTM#1000-53.-4-8 Physical Address:1815 Bay Shore Road,_ Greenport, NY 11944 Phone#:631-793-2878 Email:pLabarca@aol.com Mailing Address:1815 Bay Shore Road, Greenport, NY 11944 CONTACT PERSON: Name:Sue Estabrooke/Long Island Power Solutions Mailing Address:2060 Ocean Ave.,Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:sue@longislandpowersolutions.com DESIGN PROFESSIONAL INFORMATION: Name:Pacifico Engineering P.0 Mailing Address:700 Lakeland Avenue, Suite 2B Bohemia, NY 11716 Phone#:631-988-0000 Email:Solar@pacificoengineedng.com CONTRACTOR INFORMATION: Name:Michael Catizone/Long Island Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:mike@longislandpowersolutions.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ROther Proposed( 21 )panel roof mounted array. ( 7,665 )kW System $18,071.65 Will the lot be re-graded? ❑Yes R No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property:Sin le Famil Dwelling Intended use of property:Sin le Famil Dwellin 9 - -- --Y- - -g - - - g _ Y, - - . g Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes IigNo IF YES, PROVIDE A COPY. B Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Catizone Ele al/Long Island Power Solutions Application Submitted By(print ): BAuthorized Agent []Owner Signature of Applicant: Date: I D,1 d A022— STATE 022STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Michael Catizone being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate.Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this e, :. _day of e 2022 Notary Public ESCAYLIN CRISOL RIVERA RODRIGUEZ NOTARY PUBLIC-STATE OF NEW YOMROPERTY OWNER AUTHORIZATION No. 01818434031 (where the applicant is not the owner) Qualified in Suffolk County My Commission Expires 05-31-2026 residing at IRIe) fzu ire P"=,acL ' Michael Catizone/Long Island Power Solutions q do hereby authorize to apply on h f t the Town ing Department for approval as described herein. a 2tl 2.2 Owner's Sign u Date Print Owner's Name 2 i SUF�p� _ BUILDING DEPARTMENT-Electrical Inspector �CGGy' : TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr at'�,southoldtownny.gov— seandOsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION' ELECTRICIAN INFORMATION (All Information Required) Date.: Company Name: Catizone Electrical/Long Island Power Solutions Name:Michael Catizone - License No.: 36178-ME email: sue@longislandpowersolutions.com Address: 2060 OceanAvenue,Ronkonkoma,NY 11779 Phone No.: 631-348-0001 JOB SITE INFORMATION (All Information Required) Name:-Patricia Labarca Address: 1815 Ray Shore Road .Green _ortNY.11944. Cross Street: Kerwin Blvd Phone No.: =631-793-2878 BIdg.Permit#: ') email: olabarca@aol.com ' Tax Map District:_ 1000 _ Sectiori _._53___„- ___ Block: 4_ Lot: _8 . BRIEF DESCRIPTION OF WORK (Please Print Clearly) Proposed( 21 )panel roof mounted array. ( 7,665 )kW System Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) f Service Size 1 Ph 3 Ph Size: ____ _ --A #Meters Old Meter#:. New Service - Fire Reconnect- Flood Reconnect-Service Reconnected- Underground -Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information':: Modules: 21 Hanwha Q. Peak Duo 365W Inverter: (21) Enphase IQ-7PIus Support: Iron Ridge X_R 100 -PAYMENT-DUE-WITH APPLICATION Request for Inspection FormAs j 4 1 SURVEY OF PROPERTY LOT NUMBERS REFER.TO " AMENDED MAP A, PECONIC AT ARSHAMOMOOVE BAY ESTATES" FILED IN THE SUFFOLK COUNTY CLERK'S OFFICE ON MAY 19, 1933 AS FILE NO. 1124 TOWN OF SOUTHOLD FLOOD ZONES FROM FLOOD INSURANCE MAP SUFFOLK A�� SUFFOLK COUNTY, N.Y. MAP NUMBER 36103CO159H SEPTEMBER 25, 2009 Ss9 1000-53-04-08 ELEVATIONS REFERENCED TO N.A.V.D. 1988 \�`�?3� C� SCALE- 1'=30' F AUGUST 29, 2013 nem OCTOBER 15. 2013 (ADJACENT HOUSES S/B) MARCH 20, 2014(REVISIONS do PROPOSED) 'j• APRIL 15, 2014(REVISIONS) MAY 21, 2014(REVISIONS/BOH) ^e / AUGUST 28, 2015 0� CYVEETTT B BURTON PATRICIA LoSARCA FIDELITY NATIONAL TITLE INSURANCE COMPANY d� „�` +/ o• WELLS FARGO.BAW,N.A. }� `off c9 � • .. o ry16100 DDday �. ,�� o G' � APO ° F 0 CT 1 4 2022 1ry� �i� o'•eti� ��4 ��. oo�D �o BUMDING o P DEgyT a5• 'Y���r-\ �:;ii�����• ���`o�.iC��y /�.��0 O A4Fj:3 ��y TOWN N O SOUTHOLD pF NEW r0 el r O yc s Y.S UC. NO. 49618 ANY AL7ERA7ION OR ADDI77ON TO THIS SURVEY IS A WOLA770M ECONIC S WORS. P.C. AGS`/c of S£cnoN 7209oF THE NEW roRx srA7£EDUCA17ON LAW. 631 765-5 20 FAX (631) 765-1797 AREA-19,982 of w AOA ^. FJ £XOEPT ALM S£C71ON 7209—SUBDIWMDN 2 ALL CEI?nRCA71ONS AR A- 982 80 ��l HEREON ARE VALID FOR 7HIS NAP AND COPIES INEREOF ONLY IF P.O. BOX 909 + P SAID MAP OR COPIES BEAR THE IMPRESSED SEAL O°WE SURVEYOR 1230 TRAVELER STREET TOM LINE WHOSE SIGNATURE APPEARS HEREON. SOUTHOLD, N.Y. 11971 F89-4,22 LONG ISLAND O@E R 2060 Ocean Ave Ronkonkoma, NY 11779 SOLUTIONS 631348-0001 www.longislandpowersolutions.com TOWN OF SOUTHOLD—Building Division Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold,NY 11971 Dear Building Dept: As per your Building Department, enclosed please find the building permit application, submitted on behalf of our client/property owner: Property Owner: Patricia Labarca—631-793-2878 Project/Property Address: 1815 Bayshore Road, Greenport,NY 11944 Section/Block/Lot: 1000-53-4-8 Electrician/36178-ME: Michael Catizone—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Contractor/53562-H: LI Power Solutions—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Architecture&Planning: Pacifico Engineering—700 Lakelalnd Ave, Ste 2B,Bohemia,NY 11716- 631-988-0000 Enclosed Please find: • Application Fee: $200.00 • Permit Application • (4) Copies of the Property Survey • (4) Copies of the Engineering Drawings & Specs • Liability, Disability& Workman's Comp Insurance Certs Please send the Receipt and Permit to Long Island Power Solutions. Should you require anything further, please contact me. Sincerely, Sue Estabrooke, Permit Manager E Long Island Power Solutions V 2060 Ocean Avenue 0 CT 1 4 2022 Ronkonkoma,NY 11779 Ph- 631-348-0001 Fx- 631-348-0018 PUI�D�IO-B1�:P':l'' sue@Gopowersolutions.com 'TOv�YN OF50�17i1lOLD Go Green Save Green t — Suffolk County Dept.of } Labor,Licensing&Consumer Affairs j ti HOME IMPROVEMENT LICENSE Name _ I MICHAEL J CATIZONE Business Name This certifies that the Dearer is duly licensed LONG ISLAND POWER SOLUTIONS INC 3y the County of Suffolk License Number:H-53562 Rosalie Drago Issued: 06/06/2014 Commissioner Expires: 06/01/2024 r= Suffolk County,Dept-of-. l = Labor.Licensing&Consumer Affairs c F- VASTER_EL�C�ICaLL10ENSE - Name MICHAEL.CATIZONE- I y I business Namo: i "js cerlfies that trP LONA i1 LAKD-POVdER SOLU71ONS iNG { Dearer is cult'licerA9 . i oi.tre-Ccunly,of wifolk r .- License Number:ME-5?860 Rosatla Drago Issued: 0"o106i2014_ Ccmrn:ssioner Expites: 06101=24, siro,olk County Dept:of Lobor,Licensing 1L Consumer Affa-14' MASTER ELL-C-TR:ZFL L'CF-15 Nam- h'Cf it d CAVZONr Cua:raas l�arre 714c9R,-4,1;mad t is V.,d-c_,!r•,�u r icrryvrd Cjt�-O+e ve�f••ie'(%o^!:�=t':;,f'x Ueeme Nurniter N!Sw3411%8 Ropafh orago Issued: 12'01 u r s a may: Expires 120 1124,123 Client#:83176 CATIELE ACORD. CERTIFICATE OF LIABILITY INSURANCE DATE(MMMD/YYYY) 6/27/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Commercial Support Edgewood Partners Ins.Center PHONE FAX A/C No Ext): A/C No): Marcus Drive E-MAILD 3rd Floor SS: NECertificates@epicbrokers.com 3r Melville,NY 11747-2647 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Utica Mutual Insurance Company 25976 INSURED INSURER B: Catizone Electrical Inc • 2060 Ocean Avenue INSURER C: Ronkonkoma,NY 11779 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR INSR WVD POLICY NUMBER MWDD M/ MDD A X COMMERCIAL GENERAL LIABILITY X CPP4784747 7/01/2022 07/01/2023 EACH OCCURRENCE $110001000 CLAIMS-MADE 5X OCCUR PREMISES EaEoNcoufran.) $100,00() MED EXP(Any one person) $10,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 X POLICY F JECT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNEDPROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident $ UMBRELLA LIAB HOCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ A AND EMPLOYERS'LIABILITY WORKERS COMPENSATION 4766763 7/01/2022 07/01/202 X PER OTH- ANY PROPRIETORIPARTNER/EXECUTIVE Y/N E.L.EACH ACCIDENT $500,000 OFFICER/MEMBER EXCLUDED? F N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $500 000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Town of Southold is included as additional insured for general liability coverage as required by written contract. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016103) 1 of 1 The ACORD name and logo are registered marks of ACORD #S4115391/M4115046 KOS01 <NTE,'wRworkers' CERTIFICATE OF INSURANCE COVERAGE TE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured CATIZONE ELECTRICAL CONTRACTING, INC. 2060 OCEAN AVE 646-383-3599 RONKONKOMA, NY 11779 Work Location of Insured(Only required ifcoverage is specificallylimited to 1c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-up Policy) or Social Security Number 45-5213112 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Standard Security Life Insurance Company of New York TOWN OF SOUTHOLD � Y P Y 53095 ROUTE 25 3b.Policy Number of Entity Listed in Box"1 a" SOUTHOLD, NY 11971 R97483-000 3c.Policy effective period 1/1/2015 to 12/15/2022 4. Policy provides the following benefits: Q A.Both disability and paid family leave'benefits. 0 B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: Q A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as des d above. Date Signed 12/16/2021 By (Signature of insurance carrier's authoriz d representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box 4C or 513 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave,Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) �I�II�iIIIIIlII11II�IWIIIIII10Inl17ull��� Additional Instructions for Form 1313-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in box"1 a"for disability and/or paid family leave benefits under the New York State Disability and Paid Family Leave Benefits Law. The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices my be sent by regular mail.)Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Disability and/or.Paid Family Leave Benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or paid family leave benefits policy indicated,on this form, if the business continues.to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of NYS Disability and/or Paid Family Leave Benefits Coverage or other authorized.proof that the business is complying with the mandatory coverage requirements of the New York State Disability and Paid Family Leave Benefits Law. DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand and twenty-one,the payment of family leave benefits. for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any.such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand eighteen,the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (10-17)Reverse YORK Workers' CERTIFICATE OF STATE Compensation Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Catizone Electrical Contracting Inc. 631348-0001 060 Ocean Avenue - Ronkonkoma, NY 11779 1 c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,a Wrap-Up Policy) 1d.Federal Employer Identification Number of Insured or Social Security Number 202241963 2.Name and Address of Entity Requesting Proof of Coverage(Entity 3a.Name of Insurance Carrier Being Listed as the Certificate Holder) Utica Mutual Insurance Company 3b.Policy Number of Entity Listed in Box 1 a" Town Southold 4766763 53095 Route 25 3c.Policy effective period Southold,NY 11971 07/01/2022 to 07/01/2023 3d.The Proprietor,Partners or Executive Officers are E] included.(Only check box if all partners/officers included) E, all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers"Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its.licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the-policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the-New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Leonard Scioscia (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 6/24/22 (Signature) (Date) Title: Authorized Representative Telephone Number of authorized representative or licensed agent of insurance carrier: 631-390-9700 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov Workers' Compensation Law Section 57. Restriction on issue of permits and the entering into contracts unless compensation is secured. 1. The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, and notwithstanding any general or special statute requiring or'authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department,board,commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been.secured as provided by this chapter. C-105.2(9-17) REVERSE Client#:83393 LONGISL15 TE ACORU, CERTIFICATE OF LIABILITY INSURANCE FD2/07/ /DDIYYYY) /o7/2oz2 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Commercial Support Edgewood Partners Ins.Center PH°NE 631-390-9700 FAX 631-390-9790 40 Marcus Drive --Ma Le Exe: arc,Ne 3rd Floor ADDRESS: NECertificates@epicbrokers.com Melville,NY 11747-2647 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Southwest Marine&General Ins Co 12294 INSURED INSURER B Long Island Power Solutions,Inc. DBA New York Power Solutions INSURER C: 2060 Ocean Avenue INSURER D: Ronkonkoma,NY 11779 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR INSR WVD POLICY NUMBER MM/DD MM/DD A X COMMERCIAL GENERAL LIABILITY PK202200020693 2/28/2022 02/28/2023 EACH OCCURRENCE $1,000,000 CLAIMS-MADE a OCCUR PREMISES Eaocccurrence $300 000 X PD Ded:5,000 MED EXP(Any one person) $10,000 X Contractual Liab. PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: I GENERAL AGGREGATE $2,000,000 POLICY�J CT F LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ A AUTOMOBILE LIABILITY PK202200020693 2/28/2022 02/28/202 COMBINED SINGLE LIMIT Ea accident 1,000,000 ANY AUTO BODILY INJURY Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE X AUTOS ONLY X AUTOS ONLY Per accident $ A X UMBRELLA LIAB X OCCUR EX202200001789 2/28/2022 02/2812023 EACH OCCURRENCE $5,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $5,000,000 DED X RETENTION$10000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/NATUTE ANY PROPRIETOR/PARTNER/EXECUTIVEE.L.EACH ACCIDENT $ OFFICER/MEMBEREXCLUDED?, F-1 N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS r LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Town of Southold is included as additional insured for general liability coverage as required by written contract. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S3438616/M3437780 LJACO �aP workers'' CERTIFICATE OF INSURANCE COVERAGE Z T Compensation �. Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured LONG ISLAND POWER SOLUTIONS INC DBA NEW YORK 2060 OCEAN AVE OWER SOLUTIONS 6313480001 RONKONKOMA,NY 11779 " Work Location of Insured(Only required if coverage is specifically limited to 1 c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 27-1175107 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) TOWN OF SOUTHOLD Standard Security Life Insurance Company of New York 53095 ROUTE 25 3b.Policy Number of Entity Listed in Box 1a SOUTHOL"D, NY 11971 R97411-000 3c.Policy Effective Period 1/1/2015 to 7/19/2023 4. Policy provides the following benefits: © A.Both disability and Paid Family Leave benefits. E] B.Disability benefits only. C.Paid Family Leave benefits only. 5. Policy covers: Q A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as desc' d above. Date Signed 7/20/2022 By """" (Signature of insurance carrier's authorlied representative or NYS licensed insurance agent ofthat insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT:lf Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 413,4C or 513 of Part i has been checked) State of New York Workers' Compensation Board According,to information maintained by the NYS Workers' Compensation Board, the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) IIIIIPiuimioiiioi1iiiiiiioi—ii®ii1l1 Additional Instructions for Form D13-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law. The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage(Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit, license.or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first, two thousand eighteen,the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (12-21)Reverse 5 N Y S I F PO Box 66699,Albany,NY 12206 New York State Insurance Fund nySlf.conl CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 271175107 ❑� � LOVELL SAFETY MGMT CO.,LLC , 110 WILLIAM STREET 12TH FLR NEW YORK NY 10038 mill SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER LONG ISLAND POWER SOLUTIONS INC TOWN OF SOUTHOLD 2060 OCEAN AVENUE 53095 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2467 078-8 539135 04/01/2022 TO 04/01/2023 03/08/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2467 078-8, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT MICHAEL CATIZONE VICE PRESIDENT JOSEPH MILILLO TWO OF TWO OFFICERS LONG ISLAND POWER SOLUTIONS INC THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND �l2 DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 396794370 1®®®100000000000®02®0 5641 In Farm WC-CERT-NOPRINT Version 3(08/29/2019)[WC Policy-246707881 U-26.3 198 [00000000000102106564][0001-000024670788][SSZ][15840-36][Cert—NoP-MT_1][01-00001] OWER PHOTOVOLTAICS: OFS(OLUTIONS NEMA 3R (21) Q.PEAK DUO BLK-G10+ 365 2060 OCEAN AVENUE JUNCTION BOX , RONKONKOMA, NY 11h9 INVERTERS: (631)348-0001 BLACK-L1 ENGAGE CABLE (21) ENPHASE IQ7PLUS-72-2-US RED-L2 LaBarca; GREEN-GROUND CIRCUITS: (1) CIRCUIT OF (11) MODULES RESIDENCE (1) CIRCUIT OF(10) MODULES 1815 BAY SHORE ROAD GREENPORT, NY 11944 631-793-2878 S: 53 B: 4 L: 8 PROJECT DATA:#226065 INVERTER:(21)ENPHASE I07PLUS-72-2—US #12 AWG THWN FOR HOME RUNS UNDER 100' MODULES:(21)Q.PEAK DUO BLK-G10+365 #10 AWG THWN FOR HOME RUNS OVER 100' RACKING:IRON RIDGE XR100 (1)LINE 1 METER WATTAGE:7,665 (1)LINE 2 (1)GROUND �� x ROOF TYPE:COMPOSITION SHINGLES PER CIRCUIT ,p� �� WIND LOAD:-54.6PSF 0 130MPH IN 1"OR 14'PVC CONDUIT ® 1 AIe CU 1 k i71 125.41 A FASTENER:5116"DIA.5"SS LAGS NWIMLM&ATWAGVMTAGE 240 VELECTRIG SHOCK HAZARD .® . E IN GG TERMINALS ON BOTH THE UNEMD PHOTOVOLTAIC - il - e SITION MAIN SOLAR SYSTEM 7�Lakeland Ave, spite 26 Bohemia,NY t 1716 IN THE �' "• AC DISCONNECT Ph,-631-988-00A0 MAIN SERVICE solar@pacfcoengineering.com 200A WWW.pacificoengineering-corn 125A LOAD CENTER 40A BREAKER LOAD SIDE TAP ��Qf Nje' (1)-20A BREAKER �'P�pN PAC/ 0, PER CIRCUIT v LM= DISCONNECT INVERTER OUTPUT CONNECTION 1 �° 00 NOT RELOCATE THIS #8 AWG THWN OVERCUIRRENT DEVICE (1)LINE 1 AC DISTRIBUTION PANEL ®FEaSst P' (1)LINE 2 OR SUB PANEL B RATION OF THIME S DOCUMENT EXCEPT BY A o (1)NEUTRAL ALTELICENSED PROFESSIONAL IS ILLEGAL N (1)EGC CN IN 1"PVC CONDUIT PAPER SIZE:11"x 17'(ANSI B) = DATE: 8/29/2022 DESIGN BY: MW CHECKED BY: EE m REVISIONS: (1)9112122 MW cuJ to AC COMBINER: NOTE: 2020 RESIDENTIALCODE OF NEWYORK 2020 ENERGY 1-PHASE,MAIN LUG LOAD CENTER, 125A ALL WIRING TO MEET THE 2017 NEC AND 2020 ENERGY CODE TOWN OF SOU HOLD CODE,2017 NATIONAL ELECTRIC CODE.SCE7R6ATION CODE OF NEW YORKSTATE, 60A FUSED SERVICE RATED DISCONNECT ELECTRICAL PLAN E-1 APPROVED AS NOT B.P.# DATE: a N FEE: __. BY:---� NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO PM FOR THE FOLLOWING INSPECTIONS: Dis C`�n r) QC 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBINGlata- 3. INSULATION 4. FINAL r"RUCTION MUST n ve-,BE COMPLETE , 0. Qui l I ALL CONSTRUCTI;;i� SHALL MEET THE lie REQUIREMENTS OF THE CODES OF NEW '/Qa �� ' YORK STATE. NOT RESPONSIBLE FOR I DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF S0l rJ"n TOINN PI_4 i BOARD -- SOT D TOWN TR S T EES Cn ")CCUPANGY OR JSE-IS`UNLA#FUL , NITHOUT CERTIFICAT JF OCCUPANCY ELECTRICAL iNSPEC'TION REQUIRED Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2B P GPh:631-988-0000 Bohemia, NY 11716 I C c solar@pacificoengineering.com October 5, 2022 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Patricia La Barca Section-Block-Lot: 53-4-8 1815 Bay Shore Rd Greenport, NY 11944 1 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section A B C Mean roof height 20.0 ft 20.0 ft 20.0 ft Pitch 22 degrees 23 degrees 22 degrees Roof rafter 2x8 2x8 2x8 Rafter spacing 16 inch on center 16 inch on center 16 inch on center Reflected roof rafter span 9.0 ft 13.9 ft 9.0 ft Table R802.4.1(1)max allowable 18.5 ft 18.5 ft 18.5 ft The climactic and load information is below: Ground Wind Live Load, CLIMACTIC AND Point GEOGRAPHIC DESIGN Exposure Snow Speed,3 Pnet per pullout Fastener Type Category Load,Pg, sec gust, ASCE 7, CRITERIA psf mph psf load,Ib Roof Section A B 20 130 33 623 SS 5116"dia lag bolt,5"length B 33 623 SS 5/16"dia lag bolt,5"length C 33 623 SS 5/16"dia lag bolt,5"length Weight Distribution f. array dead load 3.5 psf �AC��r load per attachment 66.1 Ib y Q� The subject roof has 1 layer of shingles. Panels mounted flush to roof no higher than 6 inches above roof surface. Ralph Pacifico, PE R Professional EngineerI r-� Ralph I( � ineer, III��� D NY 066182 0 CT 1 4 2022 BlirL ING DEBT. TOWN GF SOUTH07-D GDOWER AERIAL N SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 f (631)348-0001 - ' LaBarca •=- r RESIDENCE ^�* 1815 BAY SHORE ROAD R GREENPORT, NY 11944 631-793-2878 R= -� r S: 53 B: 4 L: 8 PROJECT DATA:#226065 INVERTER:(21)ENPHASE 1Q7PLUS-72-2-US MODULES:(21)Q.PEAK DUO BLK-G10+365 RACKING:IRON RIDGE XR100 R-1 WATTAGE:7,665 # MODULES (5) SHEET INDEX ROOF TYPE:COMPOSITION SHINGLES PITCH: 22° WIND LOAD:-54.6PSF @ 13OMPH AZIMUTH: 3040 S-1 SITE PLAN FASTENER:5/16"DIA.5"SS LAGS ccs, S-2 DETAILS E-1 ELECTRICAL PLAN O L-1 MOUNTING PLAN ;I R-2 700 Lakeland,Ave; Suite 26. # MODULES (7) Bohemia,NY 11716 PITCH: 23° Ph 634-988-0000. R-3 AZIMUTH: 124° ss,40 # MODULES (9) solar@pacificnengin.eenng,pom wVvvv_pacificoengineering-coma PITCH: 23° IGENERALNOTES AZIMUTH: 124° 3'-5" -ENPHASE IQ7 PLUS MICRO INVERTER 51-$�� LOCATED ON ROOF BEHIND EACH MODULE. ,��,4F�EiYy -FIRST RESPONDER ACCESS MAINTAINED �,�Q-P�QN Aan0, .A AND FROM ADJACENT ROOF. -WIRE RUN FROM ARRAY TO CONNECTION IS ac /PO I 40 FEET. N� —COGEN DISCONNECT IS LOCATED 04 ADJACENT TO UTILITY METER. O�j —LAYOUT SUBJECT TO CHANGE BASED ON ALTERATIO1VO� ®�NTEXCEPT BYA q m SITE CONDITIONS AT DATE OF INSTALL LICENSED PROFESSIONAL IS ILLEGAL cioPAPER SIZE:11"x 17"(ANSI B) N co ® ILEGEND DATE: 8/29/2022 co N DESIGN BY: MW ® GROUND ACCESS POINT CHECKED BY: EE a � REVISIONS: (1)9112122 MW COGEN DISCONNECT ® UTILITY METER J FIRST RESPONDER ACCESS 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, REPRESENTS ALL FIRE CLEARANCEMINIMUM OF 36"UNOBSTRUCTED AS PER TOWN OF SOUTHOLD CODE,20,17 NATIONAL ELECTRIC CODE.ASCE7.16. SITE PLAN S. o INCLUDING ALTERNATIVE METHODS THE 2020 RESIDENTIAL CODE OF NYS IronRidge XR 100 RailA00WER UF V41SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631)348-0001 LaBarca Cap ` RESIDENCE �"^'dckwrq>� Flashing 1815 BAY SHORE ROAD ._ GREENPORT, NY 11944 Jac 631-793-2878 L4aclNow s• E"d - - S: 53 B: 4 L: 8 -- ' ° _:=� �- PROJECT DATA:#226065 IronRidge XR 100 Rail -.. �� � t1 tt �IrolrRidge XR 100 Rail 5/16 x 5 Stainless INVERTER:(21)ENPHASE IQ7PLUS-72-2-US Steel Lag Bolt MODULES:(21)Q.PEAKDUO BLKG10+365 RACKING:IRON RIDGEXR100 Solar Module WATTAGE:7,665 3/8-16 X 3/4 ROOF TYPE:COMPOSITION SHINGLES HEX HEAL? @GLT 1 EWIND LOAD:-54.6PSF @ 130MPH FLANGE AIUT �`1.` _ J�1 f FASTENER:5116"DIA.5"SS LAGS ' G_ GENERAL NOTES. 700 Lakeland Aye, SpR6-2B. -L FEET ARE SECURED TO ROOF RAFTERS @ 80" O.C. Bohemia,NY 1171;6 USING 5/16" x 5" STAINLESS STEEL LAG BOLTS. Ph__63i-9s 0000 solar@pacf coongineering_coni: -SUBJECT ROOF HAS ONE LAYER. www_pacificoengineering_com -ALL PENETRATIONS ARE SEALED AND FLASHED. �P Qµ 94Ci,c, o•Q ROOF PITCH RIDGE RAFTERS LENGTH OVERHANG NOTES : 2 z R1 220 2"x10" 2"x8"016"O.C. 12' 16" °A9o06616' �P��i� ESS1 R2 230 2"x10" 211x8"@16"O.C. 171_511 1611 3 ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL R3230 211x1011 2"x81'@16"O.C. 12' 161' PAPER SIZE:it"x17°(ANSI B) N DATE: 8/29/2022 DESIGN BY: MW `-' CHECKED BY: EE REVISIONS: (1)9112122 MW c U m CD 19 J DESIGNED AS PER ASCE 7-10 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, ■� MODULES MOUNTED FLUSH TO ROOF TOWN OFSOUTHOLDCODE,2017NATIONALELECTRICCODE.ASCE746. DETAILS : NO HIGHER THAN 6"ABOVE ROOF SURFACE ADOWER PHOTOVOLTAICS: WSOLUTIONS (21)Q.PEAK DUO BLK-G10+ 365 2060 OCEAN AVENUE, NEMA 3R RONKONKOMA, NY 11779 JUNCTION BOX INVERTERS: (631)348-0001 BLACK-L1 ENGAGE CABLE (21) ENPHASE IQ7PLUS-72-2-US LaBarca RED-L2 CIRCUITS: GREEN-GROUND (1) CIRCUIT OF (11) MODULES RESIDENCE (1) CIRCUIT OF (10) MODULES 1815 BAY SHORE ROAD GREENPORT, NY 11944 631-793-2878 S: 53 B: 4 L: 8 PROJECT DATA:#226065 INVERTER:(21)ENPHASE IQ7PLUS•72-2-US MODULES:(21)Q.PEAK DUO BLK-G10+365 #12 AWG THWN FOR HOME RUNS UNDER 100' RACKING:IRON RIDGE XR100 #10 AWG THWN FOR HOME RUNS OVER 100' ® y METER - WATTAGE:7,665 (1)LINE 1 ROOF TYPE:COMPOSITION SHINGLES (1)LINE 2 ��A 6 ' ��� WIND LOAD:-54.6PSF @ 130MPH (1)GROUND FASTENER:5/16"DIA.5"SS LAGS PER CIRCUIT � �11_11W 25.41 A _ IN 1"OR 14"PVC CONDUIT &WARNING r. N91L �,GI.T V ELECTRIC SHOCK HAZAR'D DO NOT TOUCH TERMINALSPHOTOVOLTAIC TERMINALS ON BOTH THE LINE AND 700 Lakeland.Ave; e-213S'it A ' ' MAIN SOLAR SYSTEM I Bofiemie,NY -if-7,16' IN THE OPEN POSITION AC DISCONNECT I Ph:631-98&E}OOU MAIN SERVICE solar@ppq fico engineering:eoril 200A www.pacificoengineeing-coin 125A LOAD CENTER _ vs 40A BREAKER LOAD SIDE TAP '`�ioFP Ej/j/ y (1)-20A BREAKER * Q' v PER CIRCUIT DISCONNECT INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS #8 AWG THWN AC DISTRIBUTION PANEL \ROFFS.510'PV OVE?RCURRENT DEVICE (1)LINE 2 pw.w. •rna ( )LINE 1 OR SUB PANEL ALT LI LENSEDPROFESSIONALIS MEILLEGALBYA (1)NEUTRAL PAPER SIZE:11"x 17"(ANSI B) (1)EGC 0 N IN 1"PVC CONDUIT DATE: 8/29/2022 20 DESIGN BY: MW CHECKED BY: EE a REVISIONS: (1)9112122 MW U f0 CD J AC COMBINER: NOTE: 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, E 1-PHASE,MAIN LUG LOAD CENTER, 125A ALL WIRING TO MEET THE 2017 NEC AND 2020 ENERGY CODE TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE746. ELECTRICAL PLAN ■ 60A FUSED SERVICE RATED DISCONNECT Arm)OWER '41SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631)348-0001 LaBarca RESIDENCE 1815 BAY SHORE ROAD GREENPORT, NY 11944 0 631-793-2878 S: 53 B: 4 L: 8 1 17'-5" PROJECT DATA:#226065 INVERTER:(21)ENPHASE IQ7PLUS-72-2-US MODULES:(21)Q.PEAK DUO BLK-G10+365 RACKING:IRON RIDGE XR100 WATTAGE:7,665 ROOF TYPE:COMPOSITION SHINGLES WIND LOAD:-54.6PSF @ 130MPH FASTENER:5/16"DIA.5"SS LAGS R-1 R-2 =� # MODULES (5) # MODULES (7) j' _ ' G . PITCH: 22' PITCH: 23' 700LakelandAve, Suite 2B. AZIMUTH: 304° AZIMUTH: 124° Bohemia,NY 11716 Ph:631-988-0000 solar@pacificoengineering,corn www-pac ificoengiri seri ng_com ❑ P��Q H p F�'r 1 CO QPact �QAC/,c� 17' 5 11' 4 8.5' 0 9�FESSION 'CDALTERATION OF T NT EXCEPT BY A O R-3 LICENSED PROFESSIONAL IS ILLEGAL 4 0 PAPER SIZE:11'x 17"(ANSI B) CD `° ■ SPLICE BAR 6 # MODULES (9) DATE: 8/29/2022 N N © PENETRATIONS 40 o DESIGN BY: MW cc PITCH: 23 O CHECKED BY: EE REVISIONS: (1)9112122 MW a. UFO 54 ci 40MM SLEEVE 24 AZIMUTH: 124 END CAPS 24 CONSUMPTION o CRITTER GUARD 190' MOUNTING PLAN L-1 1 i powered by � i • •• � ® I TOP BRAND PV � [7tan►E / 021 USA Warranty 0 CELLS Rodd 3 Purlannce Yield Security G.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area,lower BOS costs,higher power classes,and an efficiency rate of up to 20.6%. „ INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect,Traceable Quality Tra.QM. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). 2 A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year lr r linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY ( ' Q.ANTUM DUO Z Technology and the integrated high-powered Enphase IQ 7+Mlcroinverter achieving maximum system efficiency. RELIABLE ENERGY MONITORING Seamless management with the intelligent Enphase EnlightenTM'monitoring system. RAPID SHUTDOWN COMPLIANT Built-in rapid shutdown with no additional components required. THE IDEAL SOLUTION FOR: 'APT test conditions according to IEC/TS 62504-1:2015,method A(-1500V,gbh) /,�\/r��I 'See date sheet on rear far further Information "0 Rooftop arrays ion n residential buildings Engineered in Germany OCELLS • r . MECHANICAL SPECIFICATIONS Format 67.6 in x 41.1 in x 1.571n(including frame) (1717mm x 1045mm x 40mm) aa•ampm) rae(cmmm> 2as•rmamm) Weight 46.3 lbs(21.0 kg) Front Cover 0.131n(3.2mm)thermally pre-stressed glass + ¢ with anti-reflection technology 4•emwd0 Waa.0=(.5mm) Back Cover Composite film sacaaasspm) Frame Bleck anodized aluminum au•porsmm) Cell 6 x 20 monocrystelllne O.ANTUM solar half cells tba Junction Box 2.09-3.98 x 1.26-2.36 x 0.59-0.711n(63-101x 32-60 x 15-18mm), r� Protection class IP67,with bypass diodes Cable 4mm2 Soler cable;(+)2:45.3in(1150 mm),(-)%33.51n(850 mm) b ..ebww.mmEro.a a Connector St6ubll MC4;IP68 (40mm1 DETAILA nxw'aemm) o.rc rPU5-)j-O T_oatt-(Hamm) AC OUTPUT ELECTRICAL CHARACTERISTICS 107PLUS-72-ACM-US OR 107PLUS-72-E-ACM-US Peak Output Power [VA] 295 AC Short Circuit Fault Current over 3 Cycles 5.8 Arms Max.Continuous Output Power [VA] 290 Max.Units per 20A(L-L)Branch Circuit 13 Nominal(L-L)Voltage/Range [V] 240/211-264 Overvoitage Class AC Port III Max.Continuous Output Current [A] 1.21 AC Port Backfeed Current 18mA Nominal Frequency [Hz] 60 Power Factor Setting 1 Extended Frequency Range [Hz] 47-68 Power Factor(adjustable) 0.85 leading...0.85lagging DC ELECTRICAL CHARACTERISTICS. POWER CLASS 360 365 360 365 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W1-0 W) Min.Power at MPP' PM [W] 360 365 Min.Current at MPP lmp [A] 10.49 10.56 Min.Short Circuit Current' Im [A] 11.04 11.07 Min.Voltage at MPP VMw [V] 34.31 34.58 Min.Open Circuit Voltage' Voc [V] 41.18 41.21 Min.Efficiency' q (%] %20.1 120.3 'Measurement tolerances PM t3%;Iso;Voc 15%at STC:1000W/m2,25±20C,AM 1.5 according to IEC 60904-3 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE --r-----r-----r--------- _,mm,,,,,�,,,a. At least 98%of nominal power during 5 first year.Thereafter max.0.5% LLQw -------- --- degradation per year.At least 93.5% rao __L-----L____ of nominal power up to 10 years.At ir I it F g least 86%of nominal power up to a ra > 5° 25 years. c '° --r-----r-----�----------- 4 aZ 5 z -j All data within measurement toleranc- i $ a as.Full warranties in accordance with aeo .ao No IN 1000 �- the warranty terms of the O CELLS IRRADIANCE[W/m'] 0 „ sales orgenisation of your respective N o • u u m a country. n .� YEARS Typical module performance under low Irradience conditions in m comparison to STC conditions(25°C,1000 W/m2) TEMPERATURE COEFFICIENTS a Temperature Coefficient of Is. a [%/K] +0.04 Temperature Coefficient of V� [%/K] -0.27 s Temperature Coefficient of PMpp y [%/K] -0.34 Nominal Module Operating Temperature NMOT ['F] .109 5.4(43±3°C) " m 0 PROPERTIES FOR DC SYSTEM DESIGN o Maximum System Voltage Vsys [V] 1000 PV Module Classification Class II Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 Max.Design Load,Push/PUI13 [lbs/ft2] 75(3600Pe)/55(2660Pa) Permitted Module Temperature -40°Fupto+185°F Max.Test Load,PUsh/Pull3 [lbs/ft2] 113(5400Pa)/84(4000Pe) on Continuous Duty (-40°C up to+85°C) 3See Installation Manuel Px QUALIFICATIONS AND CERTIFICATES � Soler module:UL 61730, U.S.Patent No.9,893,215(soler cells); m Enphaso mlem Inverter.UL 1741-SA,UL 62109-1. UU741/IEEF1547,FCC Pert 15 Class B, o ICES-0003 Class B.CAN/CSA-022.2 NO.107.1-01, ` Rapid Shutdown Compliant per NEC-2014 &2017&C221-2015 n m Note:Installation instructions must be followed.See the Installation and operating manual or contact our technical service department for further information on approved Installation and use of this product Hanwhe O CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 981 EMAIL Inqulry@us.q-cells.com I WEB www.q-cells.us Data Sheet Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready p Enphase IQ 7 MicroTM and Enphase IQ 7+ Micro'" Q 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'M, Enphase IQ Battery'M, and the Enphase Enlighten" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy.to Install • Lightweight and simple Faster installation with improved,lighter two-wire cabling 1 Built-in rapid shutdown compliant(NEC 2014&2017) 1Ito Productive and Reliable •.Optimized for high powered 60-cell and 72-cell*modules More than a million hours of testing • Class II double-insulated enclosure UL listed 0 Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements w - Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U� *The IQ 7+Micro is required to support 72-cell modules. EN PHAS E. To learn more about Enphase offerings,visit enphase.com f Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235 W_350 W+ -_- -- _ 235 W-440 W+ ) ---- ------- ---------------------- ------- --------- - ---- - - -- ---------- Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules -Maximum input DC voltage —48 V ��-' _____6_0_V Peak power tracking voltage 27V-37V 27 V 45 V Operating range ------ ------------------16 V-48V------------ -- -- 16 V_-60 V-------------------------------, •---_---_ ---- --- -------- - --- --------- ---- -- -- --- - --- - - - - - --- -- - Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A - — 15A - Overvoltage class DC port II II DC port backfeed current O A O A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA _ _295 VA Maximum continuous output power - 240 VA _ --- - - 290 VA -__— {Nominal(L L)voltage/rangez - 240V/- -------208V/- 240 V/ 208 V% 211-264 V 183-229 V 211-264 V 183-229 V -------------- ---- --- - --- - ---- -------- - --- - - - --- -- - -- - - - - - - - - - = Maximum continuous output current 1.0A(240V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) ----- `-_-- -- -- --- - --- -- - - -- ---- - - ---- - -- - -- - --, Nominal frequency--- 60 Hz _ - _ 60 Hz - Extended frequency range 47-68 Hz 47-68 Hz AC short c-ircuit fault- -current over 3 cycles -5.8-Arms 5.8 Arms ---- -- -- ----- - -- -- -- ----- -- - ------ .8 --- --- ------- - - - -- -- Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% ---------------------- -- ---__9_7.0_%____ ----- _____--- CEC weighted efficiency 97.0°i%° - ---97.0--%-- MECHANICAL 7.0°i°MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4°i to 100%(condensing) Connectortype(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-S adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 -------- ----- ----- - - - - --------- ------- ------- ------_- -- -- —--- - - - ------- Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling - - Natural convection-No fans Approved for wet locations Yes ----ution d-----egree- ----- --- - -- - - --- - ----- - - -- - -- --------- ---- - - --- -- -- PollPD3 Enclosure — - - - - Class II double-insulated,corrosion resistant polymeric enclosure - - - Environmental category/-0 V exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. _ Both options require installation of an Enphase IQ Envoy. 'Disconnecting means __ The AC and DC connectors have been evaluated and approved by UL for use as the load-break - disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at htt s:/lenphase.com/en-us/support/module-com atp ibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com u EN PHAS E. ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 4 l ®/� IRONRIDGE Roof Mount System i �p Built for solar's toughest roofs.. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated,for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Software Certified to maintain the fire resistance ® Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding 20 Year Warranty ® UL 2703 system eliminates separate Twice the protection offered by module grounding components. competitors. u XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices Q A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability • 12'spanning capability Self-tapping screws • Moderate load capability Heavy load capability • 'Extreme load capability Varying versions for rails • Clear& black anod.finish Clear&black anod.finish Clear anodized finish Grounding Straps offered Attachments FlashFoot Slotted L-Feet Standoffs Tilt Legs � t Anchor,flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware High-friction serrated face Works with vent flashing Attaches directly to rail • IBC& IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware • Certified with XR Rails Clear&black anod.finish 4"and 7" Lengths Fixed and adjustable Clamps & Grounding End Clamps Grounding Mid Clamps Q T Bolt Grounding Lugs Q Accessories up -- -�- Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish &black anod. Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips • Sizes from 1.22"to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps • Optional Under Clamps Mill& black stainless Swivels in any direction UV-protected polymer Free Resources Design Assistant ®A NABCEP Certified Training -_7, Go from rough layout to fully ®1. Earn free continuing education credits, -_77 - engineered system. For free. ` while learning more about our systems. Go to IronRidge.com/rm O® Go to IronRidge.com/training