Loading...
HomeMy WebLinkAbout48059-Z Town of Southold 5/17/2023 P.O.Box 1179 CM 53095 Main Rd Oy �Fr Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44105 Date: 5/17/2023 THIS CERTIFIES that the building GENERATOR Location of Property: 62345 CR 48, Greenport SCTM#: 473889 Sec/Block/Lot: 40.-1-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/9/2022 pursuant to which Building Permit No. 48059 dated 7/13/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory generator as applied for The certificate is issued to Sunset Sound Views LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48059 12/12/2022 PLUMBERS CERTIFICATION DATED Oor 1 ignature ;TORR TOWN OF SOUTHOLD G BUILDING DEPARTMENT a TOWN CLERK'S OFFICE oyL'• 0� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48059 Date: 7/13/2022 Permission is hereby granted to: Sunset Sound Views LLC 16 Locust Ln Glen Head, NY 11545 To: install generator as applied for. At premises located at: 62345 CR 48, Greenport SCTM #473889 Sec/Block/Lot#40.-1-5 Pursuant to application dated 6/9/2022 and approved by the Building Inspector. To expire on 1/12/2024. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $235.00 Building Inspector Of SOUryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.deviina-town.southold.ny.us Southold,NY 11971-0959 Q IyCOUNT BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Sunset Sound Views LLC Address: 62345 CR 48 city:Greenport st: NY zip: 11944 Building Permit#: 48059 Section: 40 Block: 1 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Home Owner License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Generator X INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 22kW Generator w/200A Whole House Transfer Switch Notes: Generator Inspector Signature: Date: December 12, 2022 S.Devlin-Cert Electrical Compliance Form so * # TOWN OF SOUTHOLD BUILDING DEPT. `eco 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] -CODE_VIOLATION [/] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR OF 50GlyO� -t C /� -- # # TOWN OF SOUTHOLBUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ]. FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [__,-]--CODE VIOLATION [ ] PRE C/O [ ] RENTAL ---- ------------------ - /-�--- -- - REMARKS: c%�a/t ¢/`A J� - SN L 6&�Vzq lG G J/ DATE 2- INSPECTOR V D OF SOUlyOlo - ----------- -- # * TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: -- --- -- - ---- - DATE ) ��'�! INSPECTOR 1} f!t r ' I •� Ln JcFr FIELD INSPE O P` lt' ,:, GO• . GTS. N;RE T;. 7?'ATE'!:, :.:,:,:,,. :x�, ;:`.':<,: M 1?1:TS . ;;. :..:. �'f;tt ti1:1'r:: . . ;.. :tt . ;,, : FOUNDATION': �. . -------------------- ----- ;'(, . . . _ ;m..: . tttx:...c:I '7:::3"srr.,.: FOUNDATION'(2ND);. t=1, ' 4..:::. . 1�••r.i','i:',r,:'::c?'; "1',yyf�SST 1.�ndq{'v.>�.�:�.v:l..;.::i 'j i,•.`i�)'lo-7.f:."�( d�•,;".r;r,;`)-�o4:.'rr/:vr;,'�c;''c.,:a. . .��j , , a! . . J ;F;:. . ...:.. . . . - -l.. eS�li F.'trYr;,f.S",iyg1.:„:' .... .. O 1. t' w 41 \.' ~�aiii:l.::':fir:” 1 . --N 0;.!ie..'�f:;{::',:'•.'+i::"}::•:`*„':nLi:.1'I.:t'`.Y4;•j;`!Ti`., •,::-;n;'.. —C . :c:a •.,d>+',�.I. t•Jt:?t'1�,../:K;. 'n;;.;r c'•::.:. . . , - _ Gn tr,r:- �; t'r`y' t ':'1.., �r.=at.ir...4.:3:r3,-I'l:r.. - lf.,..+.:p. ' ROUGH. — F'R5 A,1yII1' .G,i . UIVIB'X1�T.G.. IV, t,t...�.. C J +"q....'i i,t.•.]t,i5v'� "qqu�ay n-�'•,.•. ;�:',:;;'.,..::'.:; V r. . �•��:,,:•:, r.l'r�'•,,:,�,':N'.:t'A��:t:i;:'hti) s kl?)ti.A4.v.;p.;Q.wi.; ti�1"^.�; , . til; .�Cf'i:.�Y.�a .. 4y ;f;:'+;R', f 2" �r�..' a tr:=c�. •:y'', ;k.<�`,.psi:• ,�r.,sa�5'?s`:;:'.':`:.` i:. 'i�c;';=ti4;`;t``.S•j4.:1`'' y�x.i��t'�ro::�%j°:A .- E ,Ys•: lri .r;y;,.." ::is•.t},S;%{9;.i i'::• . • J, .a:x,: . ..,.J.. "!'Lrt4�t :.(.; I%!:�'�i,..V'i..,'j,fiRyr,�t.•.�(„'-"� .. . . .. 'Jt•�) '(51) . .. - .., .1 ” . _. ; ,' INSUY,ATTQN.p I2'N. k�I ;; ,...,,ti,. :::.: .: 1. n __3. -; '�:: • STATE EN`IRGX CO'AE: �. ::..�:,.;.,: k..:;;..y (' '�� . .: 1`,'• ,',.,i,,,..,..iA 4,.!'':,""i':+,(.`:. . . - ( l'+ii` - . .,J• _. .: 4•.t _ r.:w ::G:gi.;b ".'lam.' .. - -5. •` - �,.:h i •k•lstir'>,G.f";1: .',.'.i`1`I,',1-1*•. :{ii': 1, •�A!``;Ij rs.?�+a;:;a• �R(n'f=r.: n',.;'..:�:. a,tt. ,'•{' .. '1 .�f,::y .^IC 7 n" r 16, �T p r r) t!:•- 44:i.p,.• - , ' v - - 1. i ':'i: -xi'.�::•:ti rlhw;4; s„IT"a� t:qs;- v°I. 'r;•i1:}', 41rfiq�",s%r`.r.'-t.,;1Yty` .. O ♦:tai 'S,+,,"C'.F: i x:�s:T�;-�f::E:,:' � S . ''','`a•' G ,; 'ir'i:'•':'i . S.• . /'h'i's:='• iyCSJj •:.1 '-1;�{r.� � N y .:,: 0-4 o .,r:... ,•:... . .. 1:4.,, r' N . .... •. :'. . ., �. 'fr•;a .. ;r . . . .. i H .• .,. . .. . . . .. , M }'x'.:=i-ii:ii• 7ihf!,'i;1:.,;,`,;,:.ieSl',.y!;,1`;ojJ' i 'V t.;t.. rdf i`9:'.R�:l;•.:'T:t./,•S}."11i�'�S:t-al i.: ta: �'!: �F.).. ;'l: .�.•{ k • .,1,:, .1., i:'1i}'n �i:1:G•�r' tYf:aY."�..5-.`i:'-:.' .. . j::.L=. - , � 1P:.pf).f'I`•.'%:;;� ,1.a vclS \ 3., ,.,.• . .. •sT;,7 i i�:.•;:,C'4 i�:.tu'l.Ji§'aar, A.L .. . - S\;: „`aYi: ;',".;;.14;,.sl�ng1..:�5!}f1!1::t t,y,. . r :al" `, r. . ... . . I.... . .......+ ........ ., , .v.,-.!..,d'� 2, .,.. . & C- fV6 A A TOR 5;°©4gsu�iofx�� TOWN OF SOUTHOLD—BUILDING DEPARTMENT z , Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://Nvww.southoldtownny.gov I Date Received APPLICATION FOR BUILDING PERMIT or Office Use Only D '_- P PERMIT NO. BuildingIns ector: JUN 0 9 2022 Applications. forms must be filled out:in their eritiret .. Incom 'tete BUILDING DEPT. PR Y� TOWN OF SOUTHOLD applications will not be,accepted. Where the Applicant is not the.owner;an Owner's Authorization form(Page 2)shall,be.completed... , Date: Z5 2 2- OWN ER(S) OWNERS)OF PROPERTY: . Name: SCTM#1000- b -5 Project Address: 6 Z 3l(5 moo . RoL,4R- Ll li�, G-r-u� N y Phone#: ' 91-7 - /f/ 7 _ 5159 -7 Email: i +e- Pe V, 0 C,r-P-C. C, Gr..A Mailing Address: , b L-o c-(A S Lcun e- A 7 ( I 5,1J— CONTACT '`(JCONTACT PERSON: '` Name: j -t1 k 4^0 S V CLX"K cu-1 S Mailing Address: / to Lo GSA S i- L cLA e- H.S q.— Phone#: 9 i-7 - t// -7 _ Jr 5 f -' Email: .5-' e V e V C C�'-e SCP� C,Goon DESIGN PROFESSIONAL INFORMATION:'. Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATIONf Name: Mailing Address: Phone#: Email: DESCRIPTION OF:PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost ofProject: ❑Other C7-I— Iv EE AA-I $ Will the lot be re-graded? ❑Yes El No Will excess fill be removed from premises? ❑Yes El No �.1 PROPERTY,INFORMATION. ~` I. . Existing use of property:�Jl[;� 'icwLe Intended use of property* I Zone or use district in which premises is situated: Are there any covenants a�d restrictions with respect to a-u mnwnfuy ry)n h this property? ❑Yes l_{f�o IF YES, PROVIDE A COPY. Check Boz After Reading: The owner%contractor/design'professional is responsible for all'drainage and storm water issues as provided by Chapter 236 of the,Town Code.APPLICATION IS HEREBY MADE to the_IBuilding Department for the issuance of,a Building Permit'pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and.other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or.demolition as herehi'descdbed.The applicant agrees to comply,with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary inspections.False statements made herein are ` punishable as a Class A misdemeanor pursuant to Section 210.45 of the New:York State Penal Law: I Application Submitted By(print naI�d'AUthorized Agent cJwner Signature of Applican • _ N11 Date: otj/0 D )ZZ STATE OF NEW YORK) SSS COUNTY OF C ) (;f being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the via, (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her ow dge an bel' f;an that the work will be performed in the manner set forth in the application file therewith. �- " . BARBARA H.TANDiY Sworn before me this Notary Public,State Of New York No. 01 TA6086001 Qualified In Suffolk Courtly day of - — 20 0��, Commiselo t Expires 01/13/20�3 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, ST i L,I fru o S V A--P-(CA-vu residing at (0 �( �C- C P "I 8 /V y _do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein � 1 )-�; J. Z �- Owner's Signature Date -7-1 c./ +ivo S V" Print Owner's Name 2 i i BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o z Town Hall An nex - 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 y p� Telephone 1(631) 765-1802 - FAX (631) 765-9502 rogerr(cDsoutholdtownny.gov - seand -southoldtownny.clov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali Information Required) Date: ` t 5 7--?- Company 2Company Name: ohn�n w n!C Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: i JOB SITE INFORMATION (All Information Required) Name: ✓1 P4" �-L-C- S c I tw6c 9 V—qzbt�; Address: (� 23 `iS C_ ?, i r Cross Street: N o rte. o Phone No.: Of 1 '7 - Qaq-1 -1- S S 9 "7 Bldg.Permit#: L-1�?05Q email: Tax Map District: 1000 Section: Block: Lot: Jr BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO -]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3'Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION ^� BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 �o�� • C p Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(aD-southoldtownny.gov - seandp_southoldtownny.gov �rYi7ILIJ APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: f4oW�R_,o w r%� Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: &tA^S S.&, �► P.e vS �-1- 5tt I utw- Va Address: 6 23 1,t q e lqq Cross Street: Phone No.: C1 1 -7 YJ -7- S S `7 Bldg.Permit#: 9 �105q email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLU E SQUARE FOOTAGE (Please Print Clearly): CA Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# El New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 'IP 0 x , t2u � ?� D- vsl,.le �� �e �o-an1� I I LONG; ISLAND TH - SALTATER N47"47'50"E 109.80'(DEED) 107.99(ACTUAL) o � w w E-1 w 1= w O l.47 4 ,c•4 O Q I-- X ���� 6 APPAPFNT RIOT ARFTINE-(tM�� 1� 6 O 10 ! 6 O O Ln r Ln LO 12 70 00 �1 14- 16- 71 18— 14 20 76 22— -�-- 24— TOP BLUFF 8' 28 F 20 28-- 3 X 11 X 10.T,ppBTAL .'nON R UNE =4f L. 2 26 X SHED 1]' 22M X CL 3 S1 a Y N a X .P. X136 X X R_',B.Ra xV p x0 Tax Map Lot 5 p �z IT—Z N P .... X 20.5• X d4.ex , �81491n(A . 2 CHAMDKK yB I 2tlW RWSE X'76.11 x 20.5• 3 s b 42 1OA .6 SRm X X 4a s] S7.1Z X 4442 u.14 X tlA e AYP C f)t! ALU x}•'71 Ql'E /4.RB Y 45.6 7.4 CONC EPOARno o I lYA-STORY STOOP HOUSE N s1EPs 1EAA— No.62345 a 24.3''-' � 3.5 ansa zonet ..SE S STEPS ri 21.5w.1R 9 6]t X�° - SURVEY OF WAW` PROPERTY 19 9' Y v¢ wuxwAr ONY AY SI TUA TE Al w W TOWN OF SOUTHOLD „ SUFFOLK COUNTY, NEW YORK .Au IMAO x4a" 11.51 ON TAX No. 1000-040.00-01.00-005.000 X � SCALE 1°=30' tl U-) NOVEMBER 8, 2021 �0� n r AREA = 49,043 sq. ft. 1.126 ac.(DEED) OMMVAY U) O 44,270 sq. ft. 1.016 ac.(ACTUAL) Aam ` 0 z -- 4z � X o 40 Q�aS1 0 4VUT AERIAL LAND SURVEYING D.P.C. NOTE LOCATIONS AND EXISTENCE OF ANY MIL 1FNCE FE O ' SUBSURFACE 1.AUTILITIES ANO/OR SLED. THE NOT T,]Y, 53 EY, NY DRIVE READILY VISIBLE,ARE NOT CER11nEO. THE \ 2,]5 4,632,88• E: 833 78 11967 CERTIFICATIONS HEREON ARE NOT TRANSFERABLE. $ _ PHONE: 833-707G.COM _ovwnEw r(R�s_ _, _ � E-MAIL: SURVEYSOAERIALLANDSURVEYING.COM EOCE OF PpYEyTNT TE WEBSITE: WWW.AERIALLANDSURVEYING.COM THIS SURVEY IS.—CT TO ANY E—I NT OF REO—AND ANY OMER PER—T FACTS WRICR A 11 LE SEARCH YIOIT USCLOEE S56*,3 7'Z Q"W DISTRICT:1000 LOT:005.000 BLOCK:01.00 SECTION:040.00 UNN Mtl FlD ALTERAIIO.H OR A FOR TO A WRIEY YAP EE—G A 9 LHITiSEO lANO suRYE 'S EEAL IS A VIOIARON OF MnttE 134, L.L1P.66 90,QQ' J MAP/FILE NO.: N/A FECnON)209.S11WIV190N 2,OF ME NEW YOTX STATE EIXM MXI 1Ae X NORTH n..rlg-.1 tnl. ROAD MAP OF: .F n.I.4 a,,..rd.mlw (NIDD Not on a filed subdivision ma .m.d—d.wu w.o Ny•�gaUrk.U.um W '>v UTILITY POLE LE ROAD) TITLE NO.: HBA-6396—S-2021 ' tl ons Eam s',,,�Y`ep oawl.e er mi Yon s.I. 01 Pn1..I.nd IOP]Surw d aNrraYw.N.9,un mIy I.N1 cam,Iv Klan IAe.aroY I.W4•aW.m,E m nY=1 t. . IU. MAP FILED DATE: N/A aPU.r.q.«.omlw,9m.yRaw aN RN.UwU..lrAln."m,a. COUNTY TAX MAP ID: 1000-040.00-01.00-005.000 SITUATED AT: TOWN OF SOUTHOLD NOTE: SUBDIVISION MAP LOT&BLOCK •S: N A ;2 1. ELEVATIONS ARE REFERENCED TO N.A.V.D. 1988 DATUM anos ar ars {r - EXISTING ELEVATIONS ARE SHOWN THUS:X= Habitat s rac, o Y Wl*irst American live Insuran 1-OCOPYPoGMi 2031 RAIPN 1=F.. Valley National Bank Ts successors and/or assi ns BuauNDsuR9rnRc,Dr.c. -' w as their ineres s ma a JOB NO.: 21-1761C U DATE: NOVEMBER 8 2021 C� APPRO ED AS NOTED DATE: p # FEE: s. O1S QY: -�LL NOTIFY BUILDING °AR T MENT AT 765-1802, 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH FRAMI114G & PLUMBING 3. INSULATION 4. FINAL - CONSTRU-T!ON MUST BE COMPLETE - o.0, ALL CONSTRUCTRI-! SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF S - BOARD SOUTHOLD TOWN TRUSTEES N.Y.S.DEC OCCIrANCY OR USE I UNLAWFUL WITHOUT CERTIFICATE OF O���CUPANCY ELECTRICAL INSPECTION REQUIRED ECE GENERACO JUN 0 9 2022 SERIES 20/22/24 kW BUILDING DEPT. TOWN OFSOUTHOLD Residential Standby Generators Air-Cooled Gas Engine OEM_ Standby Power Rating ' INCLUDES: G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True Power'" Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz G007209-0,G007210-1(Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution TM controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available - • Electronic governor • Standard Wi-Fig connectivity, i • System status&maintenance interval LED indicators I ` ' I � • Sound attenuated enclosure ft • Flexible fuel line connector • Natural gas or LP gas operation GENERAC' • 5 Year limited warranty • Listed and labeled for installation as close as 18 in 457 mm to a I ~~M structure." " `Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. c61us or C V� US QUI ,e, LISTED u 'b Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER—ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network farm produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MGI-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby generators,Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. A OMISE ® �' `� GENERACO 20/22/24 kW Features and Benefits _ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to law oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution-Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. I GENERAL" 20/22/24 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphonB,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERACe 20/22/24 kW Specifications Generator Model G007038-1 G007042-2 G007038-3 (3007042-3 G007209-0 G007039-1 G007043-2 G007039-3 G007043-3 G007210-1 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Rated maximum continuous power capacity(LP) 2000 Watts'_ 22,000 Wats'_ 20,000 Watts* 22,000 Watts* ' 24,060 Watts* ' Rated maximum continuous power capacity(NG) 18,000 Watts* 19,500 Watts* 18,000 Watts* 19,500 Watts* 21,000 Watts' Ratedvoltoge _-_ ---_-_ Rated maximum continuous load current-240 volts(LP/N-G) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 ' _Tofal Harmonic Distortion Less than 5% I Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Phase Number of rotor poles :Rated AC frequency _. _-. 60 Hz - --- Power factor 1.0 Battery requirement(not inc[uded) ____ 12 Volts,Group 26R 540 CCA_minimum or Group 35_AGM 650 CCA_ m_it imum Unft weight(-Ib'-/kg) 448/203 466/211 436/198 445/202 455/206 Dimensians(LxWxHj'in%cm 48x25x29/121.9x63.5x73.7 - - - Sound output in dB(A)at 23 it(7 m)with generator operating at normal load** 67 67 67 67 67 Sound output In dB(A)_at 23 H(7 mj with generator in Quiet-Test"low-speed exercise mode`* 55 57 55 57 - 57 Exercise duration 5 min Y Engine Engine type GENERAC G-Farce 1000 Series Number of cylinders 2 Displacement999 cc CylinderIblock Aluminum vffcast iron sleeve - ------- --- Valve arrangement Overhead valve Ignftionsystem _ __. . ---_---------Solid-statew/magneto - Governor system Electronic __ . Compression ratio 9.5:1 Starter12 VDC Oftcapacity including titter Approx.l.9 qt/1.8 L - --- - -------- --- - � - - -- Operating rpm 3,600 Fuet consumption Natural gas ft3Po 1/22 Load 204(5.78) 228(6.46) 164(4.64)' 203(5.75) 1oad 301(8,52) 327(9.26) 287(8.13) 306(8.66) Full Load Liquid propane 0/hr(gal/hr)[L/hr] Ful Load 87 130(3 56)[183.48] 142(3.9)[14.77] 136 86(3.74)[184.15] 142 92(3.9)[14.77] _ Full Load Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG.10-12 in water column(2.49-2,99 kPa)for LP gas.For BTU content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of-o I peration. ;Mode_ _buttons:AUTO _•, --_„-,_• _ _ _ Automatic start on utility failure.Weekly,Bi-weekly,or onthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. - 6 - Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard ,Engine run hours Indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) - -' From 140-171 V/190 218 V Utility Voltage Loss/Return to Utility adjust able-(brownout _-. _ _ _,--__ _ Future Set Capable Exerciser/Exercise Set Error warning - - Standard •- --- — -- -- 50 t h IRuNAlarndMaintenance logs-- even s eac __ Engine start sequence - Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). - Starter cannot re-engage until 5 sec alter engine has stopped. ,Starter lock-out .--_. _ _ Smart Battery Charger Stan and Charger FaA/Missing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard -.1-1- Standard Automatic Voltage Reguation with Over and Under Voltage Protection __,_ ___ _•_- - - -_ ._._ Under-Frequency/Overload/Stepper Overcurrent Protection Standard - Safety Fused%Fuse Problem Protection Standard _ _. ,_ _ _ _ _ . _ . . Automatic Low oil Pressure/High,Oif Temperature Shutdown Standard '&orcranWOverspeed(@ 72 H.44m Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard 0 Nterriii FaulVlncorrect Wiring protection_ Standard - - - - Common external fault capability Standard ;Field upgradable firmware Standard **Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).*Maximum kilovolt amps and current are subjectto and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine powerand condition,etc.Maximum power decreases approximately 3.5%for each 1,000It(304.8 m)above sea level;and also will decrease approximately 1%for each 10°F(6°C)above 60°F(16*C). GENERAC" 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features G007039.1,6007039.3(20 kM • Intelligently manages up to four air conditioner loads with no additional hardware. Model G007043-2,G007043.3(22 kW) _ G007210.1(24 kW) poles • Up to eight additional large(240 VAC)loads can be managed when used in conjunction No,of -_- 2 with Smart Management Modules(SMMs). �—— __ _ Current rating(amps) 200 • Electrically operated,mechanically-held contacts for fast,clean connections. voltage rating(VAC)_ .� — 120/240,18 • Main breakers are rated for 80%continuous load. Utility voltage monitor(fixed)* -Pick-up 80% r • 2-pole,250 VAC contactors. -Dropout _ 65% • Service equipment rated,dual coil design. !Return---to inility�__ _ _ ___ ETL or UL listed _ Standard • Rated for both aluminum and capper conductors. r ----------- 'Enclosuretype - NEMANL 3_R �._._ • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected~�- T- - 22,000 - • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. ;�uA range^_ 250 MCM_#t3 *Function of Evolution controller Dimensions --—_ _ Exercise can be set to weekly,bl-weekly,or monthly 200 Amps 120/240,1e Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 "' Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 Dern♦ I—i� GENERACW 20/22/24 kW Available Accessories iModel# Product Description �13007101-0 Battery Pad Warmer- Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF(-18°C).(Not nec ;essary for use with AGM-style batteries). �13007102-0 ;Oil Warmer Oil warmer slips directly over the oil filter,Recommended for use if temperature regularly falls below 0 IF(-18°C), j6007108-1 tBreather Warmer ;Breather warmer is for use in extreme cold weather applications,For use with Evolution controllers only in climates where heavy icing occurs. 1GOD5621 0 Auxiliary Transfer Switch iThe auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be ;Contact Kit needed.Not compatible with 50 amp pre-wired switches, iG007027-0-Bisque JFascia Base Wrap Kit tThe fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured; f '(Standard on 22/24 kW) !appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. '13005703-0-Blsque ,Touch-Up Palnt Kit 'if,the generator enclosure is scratched or damaged,-it Is importantto touch up the paint to protect from future corrosion. t The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. iG006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a i M ! kGenerac automatic standby generator(oil not included), r +13007005-0 V WI-FI LP Tank Fuel Level ;The VIII-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank,Monitoring the Monitor LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. E (13007000-0(50 amp)(Smart Management Module'Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large 66- �13007006-0 i trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce „(100 amp) ,the overall size and cost of the system. A--- -'- '_,._--- - - - -- __ .. - . .,_... ---- -- - — _ - --' -,-- -- -_- --- ,- 1130071 69-0-413 LTE Nobila Link° Cellular - ¢The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using #13007170-0-Wi-FV iAccessories ,a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- ;Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,; ;users are taken care of before the next power outage. 313007220-0-Bisque �Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured d !appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit; i :contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs Model UPC 637.6mm 1216 mm [46.(1 mJ G007038-1 696471074185 t26.1 In) G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 712 a i�1 G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 0 0 -loll G007209-0 696471071511 G007210-1 696471084801 646 mm 1232 mm [25.61n[ [46.5 inl LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.Sea installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G E N E RACO Generac Power Systems,Inc. • S45 W29290 HWY,59,Waukesha,WI 53189 • generac.com 02021 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0000937814 Rev.D 04/14/2021