Loading...
HomeMy WebLinkAbout49093-Z suFFai� �0 KcoG� Town of Southold 5/15/2023 y` P.O.Box 1179 N x 53095 Main Rd o Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44102 Date: 5/15/2023 THIS CERTIFIES that the building GENERATOR Location of Property: 62005 CR 48, Greenport SCTM#: 473889 Sec/Block/Lot: 40.-1-1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/4/2023 pursuant to which Building Permit No. 49093 dated 4/5/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to North Rd Hotel LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49093 5/9/2023 PLUMBERS CERTIFICATION DATED Autli d S' tore w TOWN OF SOUTHOLD FaI� BUILDING DEPARTMENT ti x TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49093 Date: 4/5/2023 Permission is hereby granted to: North Rd Hotel LLC 43 Appleton PI Dobbs.Ferry, NY 10522 To: install generator as applied for. Must maintain minimum 25' setback from lot line. At premises located at: 62005 CR 48 SCTM #473889 Sec/Block/Lot# 40.-1-1 Pursuant to application dated 4/4/2023 and approved by the Building Inspector. To expire on 10/4/2024. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $235.00 Building Inspector so�jyol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin(,@-town.southold.ny.us Southold,NY 11971-0959 Q�yCOWN'�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: North Rd Hotel LLC Address: 62005 CR 48 city:Greenport st: NY zip: 11944 Building Permit#: 49093 Section: 40 Block: 1 Lot: 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Wildwood Electric License No: 4836ME SITE DETAILS Office Use Only Residential Indoor Basement Service Commerical X Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect 4 Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 30kW Kohler Generator w/ 200A Transfer Switch, 2 Pumps, 3 Phase Inverter Notes: Pump Station w/ Backup Generator Inspector Signature: Date: May 9, 2023 S. Devlin-Cert Electrical Compliance Form 4 O •� OE SOUIyo� --- # # TOWN OF SOUTHOLD BUILDING DEPT. courm,��`' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULAT�IOWCAULKING [ ] FRAMING /STRAPPING [ FINAL / , [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]' RENTAL REMARKS: t �d DATE > WV'`I INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS ro �41- FOUNDATION(1ST) ------------------------------------ re C FOUNDATION (2ND) z 0 0 H ROUGH FRAMING& PLUMBING y O t 1 r INSULATION PER N.Y. y STATE ENERGY CODE 4 1- v FINAL11 u ADDITIONAL COMMENTS 4 tA vs S=4 e cm 19 S tP4 C-0 + P- If c Z o � c� . o � ro N O � z x r� x . d ro H TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 ' Telephone 631 765-1802 Fax 631 765-9502 hrl is://www.southoldtow n ov ".4 � �a A ) ) i Y•g Date Received APPLICATION FOR BUILDING PE MIT till, tIIW/ For Office Use Only i PERMIT NO. Building Inspector APR b qn9,� Applications and forms must be filled out in their entirety.incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. DateApril 4, 2023 OWNER(S)OF PROPERTY: Name:North Road Hotel LLC SCTM#1000-040.00-01.00-001.000 Project Address:62005 Route 48, Greenport, NY 11944 Phone#:(914) 582-7861 1 Email:danielpennessi@gmail.com Mailing Address:43 Appleton Place, Dobbs Ferry, NY 10522 CONTACT PERSON: Name:Daniel Pennessi Mailing Address:43 Appleton Place, Dobbs Ferry, NY 10522 Phone#1914) 582-7861 Email:danielpennessi@gmail.com DESIGN PROFESSIONAL INFORMATION: Name:Chris Dwyer/Kevin Peterman, Engineer Mailing Address:437 South Country Road, Brookhaven, NY 11719 Phone#:(631) 286-8668, ext. 259 Email:cdwyer@lkma.com/kpeterman@lkma.com CONTRACTOR INFORMATION: Name:Sergio General Contracting Corp. Mailing Address:42 Sherman Street, Port Chester, NY 10573 Phone#:(914) 804-2022 Email:sergiocontracting@gmail.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther Electric subpanel and generator for sewer pump station $10,000.00 Will the lot be re-graded? ❑Yes R No Will excess fill be removed from premises? ❑Yes ®No 1 ' PROPERTY INFORMATION Existing use of property:Hotel/Motel/Resort Intended use of property:Hotel/Motel/Resort Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Resort Residential this property? Dyes ENO IF YES,PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/deslgn professional Is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Daniel J. Pennessi @Authorized Agent ❑Owner Signature of Applicant: a Date: April 4, 2023 STATE OF NEW YORK) SS: COUNTY OF Westchester Daniel J. Pennessi being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)heisthe member/corporate officer (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 4thday of Apri I ,2023 Notary ublic DANIEL SCHUYLER Notary Public,State of New York Reg..No.OISC5084025 PROPERTY OWNER AUTHORIZATION Qualified In Orange County (Where the applicant is not.the owner) Commission Expires August 25,2025 I� Daniel J. Pennessi residing at 43 Appleton Place, Dobbs Ferry, NY 10522 as President of North Road Hotel LLC J.Daniel JPennessi do hereby authorize to apply on my beha o th/::).7 uthold uilding Department for approval as described herein. r April 4, 2023 Owner's Si ure Date Daniel J. Pennessi Print Owner's Name 2 ® LC1114UI � l APR .x+:4_:.2023 EDBUILDING DEPARTMENT-Electrical Inspector yy � TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a southoldtownny.gov seandc@,southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Aii Information Required) Date: Li Company Name: r Name: I License No.: c,[ 3,y ._�,C email: old(, ce-Jal Address: Vc) 8 3 Phone No.: (6 3 l Q-Tq —q JOB SITE INFORMATION (All information Required) Name: Address: -, „ /fq yt� Cross Street: Phone No.: MIGA Bldg.Permit#: 44 1 p R3 email: 14 - Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK(�Plearse Print Clearly) 1 , S'J as Circle All That Apply: Is job ready for inspection?: YES /C_, Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect-Flood Reconnect- Service Reconnected- Underground -Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION L( b 23� �, $'Sa o Request for Inspection FormAs �� 11 9 a 9 3 G DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD ' T '` '�i!91 nex- 54375 Main Road - PO Box 1179 uthold, New York 11971-0959 ,•� , ephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cD-southoldtownny.gov – seanda-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: May 8, 2023 Company Name: Wildwood Electric Inc. Electrician's Name: Ralph Passantino Jr. License No.: 4836-ME Elec. email:ralphjr@wildwoodelectric.com Elec. Phone No: 631-236-2211 OI request an email copy of Certificate of Compliance Elec. Address.: P.O. Box 373, Rocky Point, NY. 11778 JOB SITE INFORMATION (All Information Required) N POA- Name: Sunset Hotel ( Pump Station Generator ) p Address: 62005 CR 48 Southold Cross Street: Chapel Lane Phone No.: 914-582-7861 Bldg.Permit#: 49093 email:danielpennessi@gmail.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Generator& P p Station Electrical connections IC F Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: ❑ YES [—V] NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 D H Frame 0 Pole Work done on Service? D Y N Additional Information: PAYMENT DUE WITH APPLICATION it -it aw low ms-mu V I —dWro—d TV U V—ct 3Md UM WNIS ftH .9 xos4Nvuaw GWA i Mwo 7tw 3nt SNOLLYON3MVW3a -1 N3l4rWWJnWVM 83d OD Of IOIVISdAnd OliN33VM -.7—, (w 3m=;) no L39�s OLL NVI 031svid M 03bnJXW.4" SV 3bnsaiw V,7 MR03A RUIA 'Na.virt 6 A9W '01 'Nin MO OK NYS Imylow xWN,3004d NOiSTkM f S � � t-T � '�" LSiOt. rwiaw nus CL WHLYMW)L*d 7tw01LON SW SMHS IIV13(3 01 SMU SZ*CT 13 401 JW d3nCWIND5 113TTVlSN' iNM 3A'VA Lo (60933 L413?00 OMW-IS nLSV3 M) Maim_' RV* (2h09) W13M -VON 1300A -3NI hWAOd VMV NOLLI)SIbLISIO 401145 dried dAnd AWJUW-c 1335WO�Jd t133HOk L9 N40 MH3MOu Iv8FUvN MSOJOW (,1! -Tavariss a3S0JG Nt" uws -11AV80 9t-aa 0.9 03sod0ad 13 .is jwot )T? f?FFr I-jq 17E 01 rj J.Y go U01 Mhi r 17V Nk. R 'OSED SDFSv'(," OR 70 COO R D I W A I `M-t N C I i JI'Fij 7Y , !PA 0 L Z ii'A1ZMNL- ZA3 %E Not. it PUPAP V% 1 -�4 .0 ar fill if L SHEET) r Ak7--, , LIMDI-r-�: - ZIN PROPOSED G As SPLR.Arl� To GEDAI--,R VxY1ILP AND (J1'1L(1'Y AS 6?!:,,LJ1R ISM N-' PINE IE w 'bad4; APPR VEDAS NO DATE: S axx3 B.P.# FEE: �'�U BY: NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: . 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS .OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF .fin -- p S0 ' .- INNING BOARD S �Y 'GtD-TOAN TRUSTFFS OCCUPANCY OR - USE IS UNLAWFUL WITHOUT CERTIFICf OF OCCUPANCY ELECTI,ICAL INSPECTION REQUIRED KOHLER. Model: 30 R C L A Multi-Fuel Natural Gas/LPG 9001 Standard Features ZSWI R. • Kohler Co.provides one-source responsibility for the NATIONALLY REGISTERED generating system and accessories. • The generator set and its components are prototype-tested, — - - P 7JI factory-built,and production-tested. ,. • The generator set accepts rated load in one step. • A standard five-year or 2000 hour limited warranty covers all systems and components. • Quick-ship(QS)models with selected features are available. See your Kohler distributor for details. • Meets 291 kph(181 mph)wind load rating. _ • GFCI service outlet installed on the junction box. • RDC2 Controller o One digital controller manages both the generator set and transfer switch functions(with optional Model RXT transfer switch). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to varying household demand. The Kohler®Advantage o Digital voltage regulation protects your valuable • High Quality Power electronics from harmonic distortion and unstable power Kohler home generators provide advanced voltage and quality. frequency regulation along with ultra-low levels of o Two-line,backlit LCD screen is easy to read in all lighting harmonic distortion for excellent generator power quality to conditions,including direct sunlight and low light. protect your valuable electronics. • Engine Features o Powerful and reliable 2.2 L turbocharged liquid-cooled • Extraordinary Reliability engine Kohler is known for extraordinary reliability and o Electronic engine management system. performance and backs that up with a premium five-year or o Simple field conversion between natural gas and LPG 2000 hour limited warranty. fuels while maintaining emission certification. • Aluminum Enclosure • Innovative Cooling System Attractive aluminum enclosure allows installation as close o Electronically controlled fan speeds minimize generator as 18 inches from your home or small business. set sound signature. • Certifications • Quiet Operation o The 60 Hz generator set engine is certified by the Kohler home generators provide quiet,neighborhood- Environmental Protection Agency(EPA)to conform to the friendly performance. New Source Performance Standard(NSPS)for stationary spark-ignited emissions. o cUL/UL listing,CSA certification standard are available (60 Hz only). o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters. o Meets NFPA 37 requirements for 18 in.offset for installation, Generator Set Ratings III, Approved for stationary standby applications in locations g served by a reliable utility source. Standby Ratings Natural Gas LPG Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps 4E5,6 120/240 1 ;6l)! 30/30 125' 30/30 125 120/240 1 60 30/30 125 30/30 125 120/208 3 60 30/38 106 30/38 106 4D8.3 127/220 3 60 30/38 100 30/38 100 120/240 3 60 30/38 92 30/38 92 277/480 3 60 30/38 46 30/38 46 * 50 Hz options available.Contact your Customer Service representative. RATINGS:AO three-phase units are rated at 0.6 paver factor.All single-phase units are rated at 1.0 power factor Due to manufacturing variations,the ratings tolerance Is.5%. Standby Ratings:Standby ratings appy to Installatiore served by a reliable utility source.The Standby rating Is applicable to varying loads vfth an average load factor of 80%for the duration of a paver outage.No overload capacity is specified for this rating.Ratings we in accordance whh ISO-30461i,BS 5514,AS 2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:Aldtuds:Derate 1.3%per 100 m(328 R)elevation above 200 m(656 R.):Temperature:Derate 3.0%per 10°C(18°F)terrIcerahue above 25°C(77°F).Availability is subject to change without notice.The generator set manufacturer reserves the right to change the design or specifications wllhout notice and without any obligation or Ilebll ty y4iatsoever.Contact your local Kohler generator distributor for avallabllity. G4.304(30RCLA) 6/21 Alternator Specifications Specifications Alternator • NEMA MG1,IEEE,and ANSI standards compliance for Manufacturer Kohler temperature rise and motor starting. Exciter type Brushless,Wound-Field • Sustained short-circuit current of up to 300%of the rated Leads:quantity,type current for up to 10 seconds. 4E5.6 4,120/240 4D8.3 12,Reconnectable • Sustained short-circuit current enabling downstream circuit Voltage regulator Solid State,Volts/Hz breakers to trip without collapsing the alternator field. Insulation: Material Class H • Self-ventilated and drip-proof construction. Temperature rise 130°C,Standby • Windings are vacuum-impregnated with epoxy varnish for Bearing:quantity,type 1,Sealed dependability and long fife. Coupling Flexible Disc Amortisseur windings Full • Superior voltage waveform from a two-thirds pitch stator and Voltage regulation,no-load to full-load X1.0%Maximum skewed rotor. Unbalanced load capability 100%of Rated Standby • Total harmonic distortion(THD)from no load to full load with Current a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (350%dip for voltages below) 240 V 4E5.6(4 lead) 44 (60 Hz) 480 V,400 V 4138.3(12 lead) 120(60 Hz) 88(50 Hz) Application Data Engine Exhaust Engine Specifications 60 Hz 50 Hz Exhaust System 60 Hz 50 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type Residential Powertrain Exhaust temperature at rated kW;dry KG2204T,2.2 L,4-Cycle exhaust,°C(°F) 633(1171) Turbocharged Maximum allowable back pressure, Cylinder arrangement In-line 4 kPa(in.Hg) 7.5(2.2) Displacement,L(cu,in.) 2.2(134.25) Bore and stroke,mm(in.) 91 x 86(3.5 x 3.4) Fuel Compression ratio 10.511 Piston speed,m/min.(ft./min.) 310(1016) 258(847) Fuel System Main bearings:quantity,type 5,plain alloy steel Fuel type Natural Gas or LPG Rated rpm 1800 1500 Fuel supply line inlet 1 in.NPT Max.power at rated rpm,kW(HP) Natural gas fuel supply pressure,kPa LPG 47.8(64.1) NA (in.H2O) 1.2-2.7(5-11) Natural Gas 47.6(63,9) NA LPG vapor withdrawal fuel supply Cylinder head material Cast Iron pressure,kPa(in.H2O) 1.2-2.7(5-11) Piston type and material High Silicon Aluminum Fuel Composition Limits* Not.Gas LP Gas Crankshaft material Nodular Iron Methane,%by volume 90 min. - Valve(exhaust)material Forged Steel Ethane,%by volume 4.0 max. - Governor type Electronic Propane,%by volume 1.0 max. 85 min. Frequency regulation,no-load to Propene,%by volume 0.1 max. 5.0 max. full-load Isochronous C4 and higher,%by volume 0.3 max. 2.5 max. Frequency regulation,steady state *1.0% Sulfur,ppm mass 25 max. Frequency Fixed Lower heating value, Air cleaner type Dry MJ/m9(Btu/ft'),min. 33.2(890) 84.2(2260) Engine Electrical " Fuels with other compositions may be acceptable.If your fuel is outside the listed specifications,contact your local distributor for Engine Electrical System further analysis and advice. Ignition system Electronic Battery charging alternator: Lubrication Ground(negative/positive) Negative Lubricating System Volts(DC) 14 Type Full Pressure Ampere rating 90 Oil pan capacity,L(qt.)§ 4.2(4.4) Starter motor rated voltage(DC) 12 Oil added during oil change(on average), Battery,recommended rating for-18°C(0°F): L(qt.)§ 3.3(3.5) Qty.,cold cranking amps(CCA) One,630 Oil filter:quantity,type§ 1,Cartridge Battery voltage(DC) 12 Oil cooler Remote Battery group size 24 § Kohler recommends the use of Kohler Genuine oil and fitters. G4.304 (30RCUU 6/21 Application Data Cooling RDC2 Controller Radiator System 60 Hz 50 Hz Ambient temperature,46C(OF) 45(113), Engine jacket water capacity,L(gal.) 2.65(0.7) Radiator system capacity,including v46nega: z4ov S Freq 80.0 Hz engine,L(gat.) 13.2(3.5) p Water pump type Centrifugal Fan diameter,mm(in.) qty.3 @ 406(16) Y no ®Q ®v Fan power requirements(powered by ® 46R Mo �x engine battery charging alternator) 12VDC,18 amps each Operation Requirements Air Requirements 60 Hz 50 Hz The RDC2 controller provides integrated control for the Radiator-cooled cooling air, generator set, Kohler®Model RXT transfer switch, m3/min.(scfm)t 51 (1800) 51 (1800) programmable interface module(PIM),and load management. Combustion air,m3/min.(cfm) 1.6(57) 1.3(45) The RDC2 controller's 2-line LCD screen displays status Air over engine,m /min.(dm) 25(900) 25(900) t Air density=1.20 kg/m3(0.075 Ibm/ft3) messages and system settings that are clear and easy to read, Fuel Consumption* even in direct sunlight or low light. Natural Gas,m3/hr.(cfh)at%load do Hz so Hz RDC2 Controller Features 100% 12.0 (424). 10.0 (353) • Membrane keypad 75%46 9.8 (345) .2 (289) o OFF,AUTO,and RUN push buttons 55/46 7. (268) 6 6.3 (222) o Select and arrow buttons for access to system 25k 5.55 (19B) 4.5 (159) Y Exercise 3.4 (121) 2.8 (99) configuration and adjustment menus LP Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz • LED indicators for OFF,AUTO,and RUN modes 100% 4.7 (166), 3.9 (138) • LED Indicators for utility power and generator set source 75% 3.7 (132) 3.0 (105) availability and ATS position(Model RXT transfer switch 50% 2.8 (100) 2.3 (61) required) 25% 1.9 (69) 1.6 (56) • LCD screen Exercise 1.2 (41) 1.0 (35) o Two lines x 16 characters per line * Nominal Fuel Rating: Natural gas,37 MJ/3m3(1000 Btu/ft3) o Backlit display with adjustable contrast for excellent LP Vapor,93 MJ/m (2500 Btu/It3) visibility in all lighting conditions 8.58 ft. LP vapor conversion factors:-1 Ib. • Scrolling system status display 0.535 m3=1 kg. o Generator set status 36.39 tt.3=1 gal. o Voltage and frequency o Engine temperature Sound Enclosure Features o Oil pressure • Sound-attenuating enclosure uses acoustic insulation that o Battery voltage meets UL 94 HF1 flammability classification and repels o Engine runtime hours moisture absorption. • Date and time displays • Internally mounted critical silencer. • Smart engine cooldown senses engine temperature • Skid-mounted,aluminum construction with two removable • Digital isochronous governor to maintain steady-state speed access panels. at all loads • Fade-,scratch-,and corrosion-resistant Kohler®cashmere • Digital voltage regulation: ±1.0%RMS no-load to full-load powder-baked finish. • Automatic start with programmed cranking cycle Sound Data. • Programmable exerciser can be set to start automatically on any future day and time,and to run every week or every two Model 30RCLA 8 point logarithmic average sound levels are weeks 53 dB(A)during weekly engine exercise and 61 dB(A)during • Exercise modes full-speed generator diagnostics and normal operation. For o Unloaded exercise with complete system diagnostics comparison to competitor ratings,the lowest point sound levels o Unloaded full-speed exercise are 52 dB(A)and 59 dB(A) respectively.* o Loaded full-speed exercise(Model RXT ATS required) All sound levels are measured at 7 meters with no load. • Front-access mini USB connector for SiteTech' connection Lowest of 8 points measured around the generator.Sound levels at other points • Integral Ethernet connector for Kohler®OnCue®Pius around generator may vary depending on Installation parameters. • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch I See additional controller features on the next page. G4-304 (30RCLA)6121 KOHL K4HLER® Phone 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-S00-544-2444 KOHLERPower.com Additional RDC2 Controller Features Available Options, Continued • Diagnostic messages Starting Aids§ o Displays diagnostic messages for the engine,generator, ❑ Block Heater,120 V,1 Ph Model RXT transfer switch,programmable interface ❑ Block Heater,240 V,1 Ph module(PIM),and load management device ❑ oil Pan Heater,120 V,1 Ph o Over 70 diagnostic messages can be displayed ❑ Oil Pan Heater,240 V,1 Ph • Maintenance reminders § One block heater or oil pan heater is recommended for ambient • System settings temperatures below 0°C(32°F). At temperatures below-18°C(0°F), o System voltage,frequency,and phase installation of both heaters is recommended. o Voltage adjustment Automatic Transfer Switches and Accessories o Measurement system,English or metric ❑ Model RDT Automatic Transfer Switch • ATS status(Model RXT ATS required) ❑ Model RXT Automatic Transfer Switch o Source availability [i Model RXT Automatic Transfer Switch with Combined o ATS position(normal/utility or emergency/generator) Interface/Load Management Board o Source voltage and frequency ❑ Load Shed Kit for RDT or RXT • ATS control(Model RXT ATS required) ❑ Power Relay Modules(use up to 4 relay modules for each o Source voltage and frequency settings load management device) o Engine start time delay Maintenance ( o Transfer time delays ❑ Maintenance kit(Includes air filter,oil,oil filter,and spark plugs) o Fixed pickup and dropout settings Miscellaneous o Voltage calibration ❑ Rated Power Factor Testing • Programmable interface module(PIM)status displays Literature o Input status(activelnactive) ❑ General Maintenance Literature Kit o Output status(active/inactive) ❑ Overhaul Literature Kit • Load control menus ❑ Production Literature Kit o Load status Warranty o Test function ❑ Extended 5-Year/2000 Hour Comprehensive Limited Warranty Generator Set Standard Features ❑ Extended 10-Year/2000 Hour Comprehensive Limited Warranty • Aluminum sound enclosure with enclosed silencer Dimensions and Weights • Battery rack and cables • cUL/US listed,CSA Certified Overall Size,L x W x H,mm(in.): 1880 x 836 x 1169 • Electronic,isochronous governor (74 x 32.9 x 46.0) • Flexible fuel line Shipping Weight,wet,kg(lb.): 599(1320) • Gas fuel system(includes fuel mixer,electronic secondary Weight includes generator set with engine fluids, sound enclosure, gas regulator,two gas solenoid valves,and flexible fuel line silencer,and packaging. between the engine and the skid-mounted fuel system components) • GFCI service outlet, 120/240 V for customer connection • Integral vibration isolation H . Line circuit breaker • NEC prime mover shutdown switch • Oil drain extension • OnCue®Plus Generator Management System • Operation and installation literature N— W—`� L '� • RDC2 controller with built-in battery charger NOTE:This drawing is provided for reference only and should not be • Standard five-year or 2000 hour limited warranty used for planning Installation.Contact your local distributor for more detailed information. Available Options DISTRIBUTED BY: Controller Accessories ❑ Lockable Emergency Stop(lockout/tagout) ❑ Programmable Interface Module(PIM) (provides 2 digital inputs and 6 relay outputs) Electrical System ❑ Battery ❑ Battery Heater ❑ On¢ue®Plus Wireless Radio Kit ®2021 Kohler Co.All rights reserved. G4-304(30RCLA) 6/21 DEMTrO nN T}HS PLM ARE MR REFERENCE ONLY g � '� -'t>i"' 1•', �r - �nth r � C 'S . s` ►#111 fi.fti. 3rn -3705 �0=MM JNG; 'r;R(XJND ELECTRIC SERV-U. OR 1G C{'<)Rf' -., TE WffH PROPERTY OWNER U"- LNC, f—,Y COMPANY AS REOLHREJ �L PUMP - Y h SHEET) ,� �. _. r �. CsC ti, 1 `1r 12 ADJA" GRADE EL 75 PROPMED GAS SERVICE TO GENERATOR. �. c• CONTRACTOR TO COORDINATE WITH PROPERTY -- .'{ E -••`� f,,� OWNER AND OWNING UTILITY COMPANY AS RM)AEA EsIST'P�ti, "J ;ftgF ------ fir.is .. NM f..F�►'�_ •.a ��t •�9 As Zig„_ ! 0 a C sc 0 a PROPOSED 8"e DR-18 GRAVIT" SEWER N p MAII _ PROPOSED ELECTRIC SERVK.k TO PF?OPOsEO NATURAL "DWEREI3 GF4tRAHOR Bt KOntEr, PROMMED �ANrFARY PUMP STATION / PUMP STACHON DISTRIBUilON AREA (OLD CASTLE ;-ANDARD ONFLIn RC509) w POWEK, INC- MODEL NO.' 30CLA (60 AZ) WIT}+ ACTiA" vI Wr N WECRAt VALVE VAULT NStALLEC CJNTROLOER Ahr MONi'frTRjNG $'STEM / TOP EL 35.25 11. c, REFER TO DETAIt SHEETS FOR - 1 [Y AD0rlIONAL MFORMATION PR4i GSEC t;A5 c j TO G17IERATON v STA1lKE55 +> Fa SiE o+,PMopRr -�-- `PR°Powo _ _ _ - r _ __ ; p C[ TQC ON, j w L_CONGET!PAD 3 ' IDE otw { ' Iem _ o EXPLOSION P3i0QF iNl'M(E tl v &IM ATION FAN 1.0'9p MLN O _ _I L �.' ► 540 CFU UN, {{ kP. 10. 2M O r d 1.725 RPH, WRh WEATHER u 1 ILWSVNE AS MANUFACTUU PLSEDC 20,� —�- �_ ✓ ~ ti �/'�"-w 9nRt!t MMM \ r. FAN TO BE SEi ON CONCRETE PAD A"ZENT TO PUMP STATION AS PER MANUFACTURER RECOMMENDATIONSIn 8 } ti `_ T'YARD \ 'y b PROP,. %" HYURANF 1' RP2 OEVICE 9091 6' HIGH iTAUEr 'i mzOwj6L LANE POLE ENCLOSURE ON CtbW BOARD FtNfu. WIT" 'X4 0 / ScAu_ ," a 1 a nu wm Tar 24-