Loading...
HomeMy WebLinkAbout47991-Z �QgUFFO1K�oG� Town of Southold 5/15/2023 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44096 Date: 5/15/2023 THIS CERTIFIES that the building ALTERATION Location of Property: 2100 Sound Dr, Greenport SCTM#: 473889 Sec/Block/Lot: 33.-1-17 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/3/2022 pursuant to which Building Permit No. 47991 dated 6/24/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as-built"kitchen alteration,HVAC and water heater to existing single family dwelling as applied for. The certificate is issued to Papagiannakis,Demetrios&Maria of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47991 5/1/2023 PLUMBERS CERTIFICATION DATED 0 V' Auth ri edature SufF co TOWN OF SOUTHOLD moo �y BUILDING DEPARTMENT H x ' TOWN CLERK'S OFFICE "oy • �� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47991 Date: 6/24/2022 Permission is hereby granted to: Papagiannakis, Demetrios 7040 Sable Ridge Ln Naples, FL 34109 To: Legalize as-built kitchen alteration, installed HVAC unit and replacement water heater at existing single family dwelling as applied for. Additional certification may be,,required. At premises located at: 2100 Sound Dr, Greenport SCTM # 473889 Sec/Block/Lot# 33.-1-17 Pursuant to application dated 6/3/2022 and approved by the Building Inspector. To expire on 12/24/2023. Fees: CO-RESIDENTIAL $50.00 ELECTRIC $180.00 AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $592.00 Total: $822.00 Building Inspector 7 O��DESOGIya� h * TOWN OF SOUTHOLD BUILDING DEPT. o . ,o CO 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:ASgJ01 LI W NO I r YD Q S W I R� spar' ,Ptir� a a r r o v ,� gri fo d®na abtA <DllC,6 /A--- AA W _Ire 6 a 30) brcatkelr t . • � v u Aryer a re Sn I do cars s rl) bA21VkeA4.,dj) jorje-,4- 7v4- 10A �f P.C�d 1 Q 4 boJ roaM o m Il 9 A een a vlmp cord DATE INSPECTOR pE SOUIyo TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ]' RENTAL 41 REMARKS: -C � ou 1 a/) ay'n' totple ovve4--� 4AA. c a A Tee A— As r� P ( fn ev.Lrlorff N n c 11901-6Al n w I A r e In- ApLrvi on � in- _e 3 DATE INSPECTOR /� _ I �oOF SOUTyo<o , ,, r - . # # TOWN OF SOUTHOLD BUILDING DEPT. `�courm ' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ IN ULATION/CAULKING [ ] FRAMING /STRAPPING [V;'-.FINAL [ ] FIREPLACE & CHIMNEY - [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [' ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: .4494!� mp r dZl3 2L . `� DATE INSPECTOR o�aOE SOUTyo! 1 I { O �/�/ # # TOWN OF SOUTHOLD BUILDING DEPT. �o • �o 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. b [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION r PRE lCn/O [ ] RENTAL R ARKS: -2 f lot t64d,tk 61"04ple —vt%e - i1-e &t^V1elr I A f! ' �Gk !1' Ill n.� ve Z_�tkd bAiwat2vile /fee e�!S� Aa ",ovu,��, o% aft f v1 1 DATE ?iv INSPECTOR �' '' �pF Sol/ * * TOWN OF SOUTHOLD BUILDING DEPT. • .ao courm, 631-765-1802 1 NSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN ULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR 50UTy0lo HZ q W S��V' �/TON F S UBUILDING DEPT. ^ourrn ' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ wzrP'R-eACY TAL REMARKS: [Nk� 15�96�7W (c - DAL DATE S - Z INSPECTOR ��_/ 4SVEF��� BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road - PO Box 1179 v' Southold, New York 11971-0959 � Telephone (631) 765-1802 - FAX (631) 765-9502 � rogerrAsoutholdtownny gov - seand(cDsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) P ' Name: ((�ri`� i flZ� Z /JJ)l.�'�"D� Address: R/ Q/ d2 /VL/ / Cross Street: Phone No.: - Bldg.Permit#: Lf-7 yqemail: TATf_F ,DM1,,ZJ ° Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIP ION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): l�G� G,lt�+ ✓1/��?Ze�ZSI/6L ( - Square Footage: Circle All That Apply: �i Is job ready for inspection. e1YES NO Rough In FfFinal Do you need a Temp Certificate?: F1 YES F-] NO Issued On Temp Information: (All information required) Service Size F11 PhF-]3 Ph Size: A # Meters Old Meter# ❑New ServiceD Fire ReconnecC Flood ReconnectMService Reconnect Ounderground[-]Overhead # Underground Laterals 0 1 2 D H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION r PNI�e �odwerin9 g� ara�' o� tet v r�J. e �G�/l,� U �S� Cei�s � �o �ai.✓e/' av�16�� �,� UA IOeAle 4t 42) a .� QC2j-J arc � $,- Pc?fl V, .Y(\Ce- wycr r19 (NJ Ila CCAA� CS (t lof �° % �D�1 e lL gyp- ��' sI r 1 J ®�®guFfOL,� BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD ° r = re Town Hall Annex - 54375 Main Road - PO Box 1179 o X Southold, New York 11971-0959 AA ® ®� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrCcD-southoldtownny.gov - sea nd(c-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: ?Ct okIS Address: a,1d0 v d. I e Cross Street: Phone No.: Bldg.Permit#: � -7qqI email: Tax Map District: 1000 Section: 3 Block: I Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): G S t A�- . SC r v i czJ Square Footage: Circle All That Apply: Is job ready.for inspection?: ❑ YES ❑ NO .F-]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On, Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# [--1 New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y DN Additional Information: PAYMENT DUE WITH APPLICATION ?�r �e PERMIT # Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven WAD Smokes DW Mini Carbon Micro Generator Combo Cooktop Transfer AC AH Hood Service Amps Have Used Special: �,/,,� Comments 7�' 00, I l 61 t r Q a ls � W- YAI-*-� k-etp e ��.f OF SOUTyO� TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINALS [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PR /O [ ] RENTAL RE ARKS: I • 0�4 4�-, 6 DATE41INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) .� H ------------------------------------ C FOUNDATION (2ND) h z �} o 01 �H ROUGH FRAMING& to y PLUMBING r INSULATION PER N.Y. STATE ENERGY CODE /3 i FINAL ADDITIONAL COMMENTS y zz &C !oa VA. A ��� 5 - m 5 Z AVIA V'117H z x E� H x d b TOWN OF.SOUTHOLD—BUILDING DEPARTMENT y S Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 y�ol �a yr3 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.jzov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ® JUN 3 N22 PERMIT NO. / / Building Inspector: A I'; '„ns and forms must lie filled out.in their;entiret .:Iricom tete TOWN OF SC. .TI•` Pp Icatio . :Y,,.:, . P. ,applications.will not`be,accepted.'Where the Applicarit is not'the owner;an."`' Owner's.Auttiorization fo"'m. pge`,2)shall 6e completed. Date:06/03/2022 OWN ER(S);OF:PROPERTY: - Name:Zan D18I(OS SCTM#1000- - Za _._. - Project Address:2100 Sound Drive,_ Greenport, NY11944 Phone#:631-807-4617 Email: Zdsparky@aol_.com _.,._. .. . .. Mailing Address:3019 30th Avenue, Suite#2F, Astoria,r NY 11102 CONTACT.PERSON: Name:Syed jaffri .._._. ..- ... - - Mailing Address:3019 30th Avenue,, Suite#2F, Astoria, NY 11102 Phone#:646-919-4383 Email: 'eewa'ee aol.com DESIGN:PROFESSIONAL INFORMATION:.. Name:Not Applicable Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Self/ Owner Mailing Address: Phone#: Email: DESCRIPTION OF.P.ItOPOSED.'.CONSTRVCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ROther Replacement of old main Electric Panel&old Electric Water Heater. $ 800+ 1000=$ 1800 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No PRO PERTY.:INFORMATION: :use of property:t Exising yIn nded perty: ... a ,_.._._._.. .,.-_..-_ _._Res,ldential-... .. .._ ... _.. ,. �nuse..----..-of pro-_..__.. -r ..,....., Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. A Check Box' Aft. Reading:, The owner/contractor%design professional is responsible for all drainage and storm water issues as provided b'y. Chapter 236 of the Town Code. APPLICATION IS.HEREBY MADE tothe Building Department for the issuance of a Building Permit pursuant to the Building Zone -•Ordfnance,of the Town of Southold,Suffolk,County;New York and.other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations 60or removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, ;housing code and.regulations and,to admit authorized inspectors.on premises and in buiiding(s)for necessary inspections.False statements made herein are punishable.as a Cla'§s A misdemeanor pursuant to'Section 210.4S'of the New York State Penal Law: Application Submitted By(print name): Zan D i a kos ❑Authorized Agent BOwner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Zan Diakos being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Owner (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Yd- day of �VtN t C , 20 X ry Public JENNA VoCKENMEISTER Notary Public,State of New Yolk 02096 PROPERTY OWNER AUTHORIZATION Q alifiedinSuffolkco nt120?� (Where the applicant is not the owner) commission Expires December , I, Not Applicable residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 From: jeewajee@aol.com Subject: 2 Application Date: Jun 3, 2022 at 1 :17:00 PM To: zdsparky@aol.com Application for Building permit is complete but needs notary on page 2 Application for Electric needs Make/Mode/Serial/ Capacity of water heater only. fp�g fFOL,� BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road-PO Boy 1179 Southold,Nev.,York 11971-09."9^rya Tolcaho a (631)765-1302 FAX (631)765 aC►?, me err�cr soa9#haldtfl �nn� cloy saancscuJtl�caldtal�mni.goa APPLICATION FOR ELECTRICAL. INSPECTION ELECTRICIAN INFORMATION (A)11n(ornfat1onRngv:od) Date;0610312022 Company Name: SELF/OWNER Electrician's fume: Liyense No.: 1=1_-c.email: Elec. Pliono No: L31 request an email cap;of Cort? of Compliance Elec.Address_: JOB SITE INFORMATION tall info mntlua RUjuirki-0) Name: 7a,n Dialcos Address: 2100 Sound Drive,Greenpart, ltiY 1194 Crass Street: Phone No.: 63'1-607,4617 E31d0.Pcrn1it,i; email: zdsparky&ol_cona Tax l'viap District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK,INCLUDE SQUARE FOOTAGE (Please Print Clearly j: 1-Replacement of old mala Electric Panel without any Addifion&,.;teration 2-f;eftla::e�a1en1 of nld lrteCtrio;.:�ter heater:�fihcsuk c,ltean�artC) U�z �n irtr^` t=ham "VVater hoater specs 21ven at bottorn.of page. Square Foota e: h�A Circle All That Apply. 1s job seady for inspection?: � YES M NO Rouch In Final Do you neer:a T omp Certificate?: --I� YES hQ Issued Orr T Tomp Information: (All infolmallan racluked) Service Sized Ph[]3 Ph Size; A #Meters Old Meter# ❑New ServiceM Fre Reconn N.-,t[FIc)od Reconnect[(-Service Recor�neCt[]UndergrourdEI0,4ethead Underground Laterals 03 H Franne n Pole Work done on SerAce? E]Y-- nN Additional Information: T+5'0 t . - 1 lvl- X �-SOM065 .57,f4' .-A 12-01VPJ� PAYMENT DUE-WITH APPLICATION Application...g Permit.pdf 3.1 MB �O�Qg�FFQ(,�.CO BUILDING DEPARTMENT- Electrical Inspector ti Gy TOWN OF SOUTHOLD C* Town Hall Annex - 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 yfj0� �aO�� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.gov — seand(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: TcSpaoN i Address: a1000 v cl hK - e.-e Cross Street: Phone No.: Bldg.Permit#: li-79q, email: Tax Map District: 1000 Section: 3 Block: I Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): G .b l� SCr v j G2-, Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO F-]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION UT 2- �e U XCUPAN'UY OR APPROVED AS NOOED USE IS UNLAWFUL DATE:6-d as B. 7'111 wrov B � FE-E:CO B WITHOUT CERTIFICATE' NOTIFY BUILDING DEPARTMENT AT OF OCCUPANCY 765-1802 9 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED K"R POU141iR)CONCRETE 2. ROUGH - FRANdW3 & PLUMBING 3, INSULATION 4, FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. COMPLY WITH ALL CODES OF ALL CONSTRUCTION SHALL MEET NEW YORK STATE & TOWN CODES THE REQUIREMENTS OF THE N.Y. :AS REQU RED AND CONDITIONS OF STATE CONSTRUCTION & ENERGY CODES. NOT RESPONSIBLE FOR SOUTH60 TOWN Z-BA DESIGN OR CONSTRUCTION ERRORS -SOUTHOLD TOWN PLANNING-pRI) S OUTHOLD TOWN TRUSTEES N.YS DEC Additional Certification May Be Required. VAW=rM REQUIRED r - - RHEEM SALES COMPANY , INC .. Acondi ci onador de Ai re Central Modelo : RA1648AJlNA Teas-i on ' Nomi nal : 2080230 V Fases : l Frecuencia : 60 Hz Corri ente Nomi nal ":: 25028 A Requi ere Ti errs, Fi .moi ca r ENSAMBLADC EN MEXICO Leer Manual de Instal acion y operaci on Anexo 92-22050-20-01 1�� "�� {x.. ,�-�: '�•'mss' } r ;} M i tener acceso a osa tes e�� n .4 4, ■ ■ ■ y� ���� � mtodinales tiros ter IN r u�tos e alimmentaclon en ser interrumpidoso " rx deb g* , n ' .t: � .1' t'•yr •1 , t e' •'t,, f'i• i� - L. :. ca;,n.;e 9;.... , .. •sY mss, „ _. .. _ ' tip __ -• ' a•`.,;'�`, c�"t: ' ♦ ' L• 1 __ S art„ P` y 4 . • •`•i �•.~ ,� k= Cyd. 1 � , � 1 Ay\ a^ t 1 � c;2- I i I ►+i iI ' I i OD • Air Conditioners ASURE Real People.Real Savings.Real Fast.• f FORM NO.ASC-222 REV.1 Sure Comfort® SA16 •' Air Conditioners • Efficiencies up to 16 SEER/13 EER • Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW] • Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kW] .@. ® usrea "Proper sizing and installation of equipment is critical to achieve optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov." • New composite base pan—dampens sound,secure wire grille, • 15"wide,industry leading corner service access—makes repairs easier eliminates corrosion and reduces number of fasteners needed and faster. • Powder coat paint finish—for a long tasting professional finish • External gauge port access—allows easy connection of"low-loss" • Scroll compressor—uses 70%fewer moving parts for higher efficiency gauge ports and increased reliability • Single-row condenser coil—makes unit lighter and allows thorough • Modern cabinet aesthetics—increased curb appeal with visually coil cleaning to maintain"out of the box"performance appealing design • Fewer cabinet fasteners—allow for faster access to internal compo- • Curved louver panels—provide ultimate coil protection,enhance vents and hassle free panel removal cabinet strength,and increased cabinet rigidity • Service trays—hold fasteners or caps during service calls • Optimized fan orifice—optimizes airflow and reduces unit sound • QR code—provides technical information on demand for faster • Rust resistant screws—confirmed through 1500-hour salt spray testing service calls • Service valve has between 3"-4"-5"valve space—provides a minimum • Fan motor harness with extra tong wires allows unit top to be removed working area of 27-square inches for easier access without disconnecting fan wire. www.SureComfort.com Sure SA16 Air • • c Conditioners Table of Contents StandardFeature......................................................................................................3 AvailableSKUs ........................................................................................................3 Features&Benefits ..............................................................................................4-5 Model Number Identification ................................................................................6-7 Physical Data/Electrical Data....................................................................................8 Accessories ............................................................................................................9 WeightedSound Power............................................................................................9 UnitDimensions......................................................................................................10 Clearances..............................................................................................................11 WiringDiagrams ....................................................................................................12 ApplicationGuidelines............................................................................................12 Refrigerant Line Size Information......................................................................13-14 PerformanceData ............................................................................................15-36 GuideSpecifications ..............................................................................................37 LimitedWarranty....................................................................................................38 2 www.SureComfort.com Sure Cornfort5 SA16 Air Conditioners Standard Feature Table STANDARD FEATURES Feature 18 24 30 36 42 48 60 R-410a Refrigerant J J J J J J J Maximum SEER 16 16 16 16 16 16 16 Maximum EER 13 13 13 13 13 13 13 Scroll Compressor J J J J J J J Field Installed Filter Drier J J J J J J J Front Seating Service Valves J J J J J J J Internal Pressure Relief Valve J J J J J J J Internal Thermal Overload J J J J J J J Long Line capability J J J J J J J Low Ambient capability with Kit J J J J J J J Expanded Valve Space J J J J J J J Composite Basepan J J J J J J J 3 Screw Control Box Access J J J J J J J 15°Access to Internal Components J J J J J J J Optimized Venturi Airflow J J J J J J J Single row condenser coil J J J J J J J Powder coated paint J J J J J J J Rust resistant screws J J J J J J J QR code J J J J J J J External gauge ports J J J J J J J Service trays J J J J J J J =Standard Available SKUs Available Models Description SA1618AJ1 NA Sure Comfort®1 1/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 SA1624AJ1 NA Sure Comfort®2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 SA1630AJ1 NA Sure Comfort®21/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 SA1636AJl NA Sure Comfort®3 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 SA1642AJ1 NA Sure Comfort®31/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 SA1648AJ1 NA Sure Comfort®4 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 SA1660AJl NA Sure Comfort®5 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 SA1618AJ1 NB Sure Comfort°11/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 SA1624AJ1 NB Sure Comfort®2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 SA1630AJ1 NB Sure Comfort®21/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 SA1636AJl NB Sure Comfort®3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 SA1642AJl NB Sure Comfort®31/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 SA1648AJ1 NB Sure Comfort®4 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 SA1660AJ1 NB Sure Comfort®5 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 SA1636AC1 NB Sure Comfort®3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/3/60 SA1642AC1 NB Sure Comfort®3 1/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/3/60 SA1648AC1 NB Sure Comfort®4 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/3/60 SA1660AC1 NB Sure Comfort®5 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/3/60 www.SureComfort.com 3 0 Sure • . o Air Conditioners Introduction to SA16 Air Conditioner The SA16 is our 16 SEER air conditioner and is part of the Sure If in the rare event,greater access is needed to internal compo- Comfort air conditioner product line that extends from 13 to 17 nents,such as the compressor,the top cover can be removed SEER.This highly featured and reliable air conditioner is easily. Furthermore with the top cover removed the control panel designed for years of reliable,efficient operation when matched can be removed(9). Extra wire length is incorporated into each with Sure Comfort indoor aluminum evaporator coils and fur- outdoor fan and compressor so top cover and control panel can naces or air handler units with aluminum evaporators. be positioned next to the unit.With minimal effort the plug can Our unique composite base(Q)reduces sound emission,elimi- be removed from the compressor and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered nates rattles, reduces fasteners,eliminates corrosion and has access to the interior of the unit(M).Outdoor coil heights range integrated brass compressor attachment inserts(❑z ). Further- from as short as 22"to 32",aiding access to the compressor. more it has incorporated into the design,water management Disassembly to this degree and complete reassembly only takes features,means for hand placement(❑3 )for unit maneuvering, a first time service technician less than 10 minutes.([1-31) screw trays(®)and inserts for lifting off unit pad.(F5 ) i IIS E i #� E�R✓t,.� ~•� ® 4 ❑3 12 All SA16 units utilize single row coils(ia)making cleaning easy Service Valves©)are rigidly mounted in the composite base and complete,restoring the performance of the air conditioner with 3" between suction and discharge valves,4" clearance back to out of the box performance levels year after year. below service valves and a minimum of 5"above the service The outdoor fan motor has sleeve bearings and is inherently valves,creating industry leading installation ease. protected.The motor is totally enclosed for maximum protection from weather,dust and corrosion.Access to the outdoor fan is made by removing four fasteners from the fan grille.The outdoor } fan can be removed from the fan grille by removing 4 fasteners in the rare case outdoor fan motor fails. ILI[ Each cabinet has optimized composite(i5)fan orifice assuring efficient and quiet airflow. 6 15 The minimum 27 square-inches around the service valves allows ;f ample room to remove service valve schrader prior to brazing, plenty of clearance for easy brazing of the suction and discharge lines to service valve outlets,easy access and hookup of low loss refrigerant gauges(Di ),and access to the service valve caps for opening. For applications with long-line lengths up to 250 feet total equivalent length,up to 200 feet condenser above evapora- tor,or up to 80 feet evaporator above condenser,the long-line instructions in the installation manual should be followed. 10r _K9 f Controls are accessed from the corner of the unit by removing only three fasteners from the control access cover,revealing the industry's largest 15"wide and 14"tall control area(®).With all this room in the control area the high voltage electrical whip(❑e) can easily be inserted through the right size opening in the bot- tom of the control area. Routing it leads directly to contractor lugs for connection.The low voltage control wires(EN)are easily connected to units low voltage wiring.If contactor or capacitor (ii)needs to be replaced there is more than adequate space to make the repair. 4 www.SureComfort.com Sure SA16 Air • 0 Conditioners All cabinet painted parts have powder post paint(is)achieving Optional Accessories 1000 hour salt spray rating,allowing the cabinet to retain its (Refer to accessory chart for model#) aesthetics throughout its life. Compressor Crankcase Heater Protects against refrigerant migration that can occur during low ambient operation 1 Compressor Sound Cover •Reinforced vinyl compressor cover containing a 11/2 inch thick batt of fiberglass insulation 18 •Open edges are sealed with a one-inch wide hook and loop fastening tape Compressor Hard Start Kit Scroll compressors with standard internal pressure relief and •Single-phase units are equipped with a PSC compressor internal thermal overload are used on all capacities assuring motor,this type of motor normally does not need a potential longevity of high efficient and quiet operation for the life of the relay and start capacitor product. •Kit may be required to increase the compressor starting Each unit is shipped with filter drier for field installation and will torque,in conditions such as low voltage trap any moisture or dirt that could contaminate the refrigerant Low Ambient Kit system. •Air conditioners operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional 20 controls •This Kit can be added in the field enabling unit to operate r properly down to 0°in the cooling mode •Crankcase heater and freezestat should be installed on com- pressors equipped with a low ambient kit 3"/6"/12" Cabinets are durable and strong due to the composite base pan •Gray high density polyethylene feet are available to raise unit (1f),wire grille(9),and drawn top cover(is). off of mounting surface away from moisture Each SA16 capacity has undergone rigorous psychometric test- Low Pressure ing to assure performance ratings of capacity,SEER •Can be added in field enabling the unit to shut off compressor and EER per AHRI Standard 210/240 rating condi- c(4D us on loss of charge tions.Also each unit bears the UL mark and each unit usT D NOTE:Unit can be purchased with high and low pressure is certified to UL 1995 safety standards. installed at factory.(Refer to SKU list) Each unit has undergone specific strain and modal testing to High Pressure assure tubing(20)is outside the units natural frequency and that .Can be added in field enabling unit to shut off compressor if the suction and discharge lines connected to the compressor unit loses outdoor fan operation. withstand any starting,steady state operation or shut down forces imposed by the compressor. NOTE:Unit can be purchased with high and low pressure All units have been sound tested in sound chamber to AHRI 270 installed at factory.(Refer to SKU list) rating conditions,and A-weighted Sound Power Level tables Decorative Top produced,assuring units have acceptable noise qualities(see •Can be installed on fan grille page 9).Each unit has been ran in cooling operation at 95°F and 82°F and sound ratings for the SA16 range from as low as 74 dBA to 77 dBA. All units have been ship tested to assure units meet stringent .,over the road"shipping conditions. As manufactured all units in the SA16 family have cooling capa- bility to 55°F.Addition of low ambient control will allow the unit to operate down to WE Factory testing is performed on each unit.All component parts meet well defined specification and continually go through receiving inspections.Each component installed on a unit is scanned,assuring correct component uti- lization for a given unit capacity and voltage.All condenser coils are leak tested with pressurization test to 550#'s and once installed and assembled,each units'complete refrigerant system is helium leak tested.All units are fully charged from the factory for up to 15 feet of piping.All units are factory run tested. The SA16 has a 10-year conditional compressor and parts war- ranty(registration required). www.SureComfort.com 5 Air Conditioners* S A 16 24 A J 1 N A Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option Category BTU/HR Code Sure A-Air Conditioners 13-13 SEER 18-18,000 [5.28 kW] A-1 st Design J-1 ph,208-230/60 1 -Single-stage N-Nan-Communicating A-1st Design N/A Comfort 14-14 SEER 24-24,000 [7.03 kW] B-2nd Design C-3ph, 208-230/60 2-Two-stage 16-16 SEER 30-30,000 [8.79 kW] 17-17 SEER 36-36,000[10.55 kW] 42-42,000[12.31 kW] 48-48,000[14.07 kW] 60-60,000[17.58 kW] 'See page 3 for available SKUs. Heat Pumps1 R. S P 14 24 A J 1 N A ' Brand Product SEER Capacity Major Series' Voltage Type Controls Minor Series— Option Category BTU/HR Code Sure P-Heat Pump 13-13 SEER 18-18,000 [5.28 kW] A-1 st Design J-1 ph,208-230/60 1-Single-stage C-Communicating A-1st Design N/A Comfort 14-14 SEER 24-24,000 [7.03 kW] C-3ph,208-230/60 2-Two-stage N-Non-Communicating 15-15 SEER 30-30,000 [8.79 kW] D-3ph,460/60 17-17 SEER 36-36,000[10.55 kW] 42-42,000[12.31 kW] 48-48,000[14.07 kW] 60-60,000[17.58 kW] CoilsFurnace ■. T C F 24 17 S T A M C A Brand Product Type Capacity Width Efficiency Metering Major Orientation Casing Minor Series" Option Category BTU/HR Device Series* Code Sure C-Evap Coil F-Furn Coil 24-24,000 [7.03 kW] 14-14" S-Standard Eff. T-TXV A-1 st Design M-Multipoise C-Cased A-1st Design N/A Comfort H-Air-Handler 36-36,000[10.55 kW] 17-17.5" M-Mid Eff. E-EEV V-Vertical only/ U-Uncased Coil 48-48,000[14.07 kW] 21-21" H-High Eff. P-Piston convertible 60-60,000[17.58 kW] 24-24.5" H-Ded. in Horizontal only C n **Model number ID's are for reference only.See available SKU page of applicable spec sheet for table of available SKU's for a specific model. 0 c [ ]Designates Metric Conversions rr n 0 i ARE . (For Reference)" S 96 V A 70 2 3 17 M S A C M Brand Series Motor Major Rev Input Stages Air Flow Cabinet Configuration Nox Minor Rev n BTU/HR Width 0 3 Sure 90-90 AFUE V-Variable speed A-1st Design 040- 42,000[12.31 kWj 1 Single-stage 3-up to 3 ton 14-14" M-Multi X-Law Nox A-1 st Design o Comfort 92-92 AFUE T-Constant 060- 56,000[16.41 kW] 2 Two-stage 5-31/2 up to 5 ton 17-17.5" S-Standard rt 95-95 AFUE Torque 070- 70,000[20.51 kW] M-Modulating 21-21" 96-96 AFUE (X-13) 085- 84,000[24.62 kW] 24-24.5" 0 P-PSC 100- 98,000[28.72 kW] 115-112,000[32.82 kW] 80% AFUE Gas Furnaces (For .. S 80 2 V A 075 3 17 M S A Brand Series Stages Motor Major Rev Input Air Flow Cabinet Configuration Nox Minor Rev BTU/HR Width Sure 80-80+AFUE 1 Single-stage V-Variable speed A-1st Design 050- 50,000[15 kW] 3-up to 3 ton 14-14" M-Multi X-Low Nox A-1 st Design Comfort 2 Two-stage T-Constant Torque(X-13) 075- 75,000[22 kW] 4-21/2 to 4 ton 17-17.5' D -Down S-Standard P-PSC premium 100-100,000[29 kW] 5-31/2 up to 5 ton 21 -21" Z -Down& S-PSC standard 125-125,000[37 kW] 24-24.5" zero clearance 150-150,000[44 kW] down flow Air Handlers1 n. S H 1 C 36 17 S T A N A A 000 ` Brand Product Stages of Motor Type Capacity Width Coil Size Metering Major Controls Voltage Minor Factory Heat Option Category Airflow BTU/HR Device Series* Series" Cap Code Sure H-Air 1-Single-Stage V-Variable 24-24,000 [7.03 kW] 14-14" S-Standard T-TEV A-1st Design C-Communicating A-1 ph,115/60 A-1 st Design 00-no 'TBD Comfort Handler 2-Two-Stage Speed 36-36,000[10.55 kW] 17-17.5" Eff. E-EEV N-Non-comm J -1 ph,208-240/60 factory heat M-Modulating C-Constant 48-48,000[14.07 kW] 21-21" M-Mid Eff. P-Piston D-3ph,480/60 with option Torque 60-60,000[17.58 kW] 24-24.5" H-High Eff. code P-PSC -Model number ID's are for reference only.See available SKU page of applicable spec sheet for table of available SKU's for a specific model. [ ]Designates Metric Conversions V Sure Comfort SA16 Air Conditioners Physical Data PHYSICAL DATA Model No. SA1618A SA1624A SA1630A SA1636A SA1642A SA1648A SA1660A Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0 Valve Connections Liquid Line O.D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line O.D.-in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant(11410A)furnished oz.s 82 87 113 108 150 174 201 Compressor Type Scroll Outdoor Coil Net face area-Outer Coil 12.1 14.8 16.2 17.29 24.2 28.3 32.3 Net face area-Inner Coil - - - - - - - Tube diameter-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 Fins per inch 22 22 22 22 22 22 22 Outdoor Fan Diameter-in. 20 24 26 24 26 26 26 Number of blades 3 2 3 3 3 3 3 Motor hp 1/8 1/6 1/5 1/6 1/3 1/3 1/3 CFM 2405 2850 3915 3300 4450 4660 4775 RPM 1095 851 710 825 829 828 795 wafts 155 147 102 167 193 198 239 Shipping weight-lbs. 147 149 159 199 212 232 247 Operating weight-lbs. 140 142 152 192 205 225 240 Electrical Data Line Voltage Data(Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection(amps)z 20 20 30 35 40 40 50 Minimum circuit ampacity3 12 14 18 21 25 25 34 Compressor Rated load amps 9 10.3 1 12.8 1 15.4 16.7 17 23.7 Locked rotor amps 47.5 61.6 1 67.3 83.9 109 123.9 152.5 Condenser Fan Motor Full load amps 0.7 0.6 1.4 0.8 3.5 5.3 3.5 Locked rotor amps 1.3 1.5 2.3 1.5 - 2.3 - Line Voltage Data(Volts-Phase-Hz) - - - 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 Maximum overcurrent protection(amps)2 - - - 20 25 30 35 Minimum circuit ampacity3 - - - 14 18 21 24 Compressor Rated load amps - - - 10.4 11.2 13.6 15.9 Locked rotor amps - - - 73 88 83.1 110 Condenser Fan Motor Full load amps - - - 0.8 3.5 3.5 3.5 Locked rotor amps - - - 1.5 - 2.3 - 'Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 'Refer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. 8 www.SureComfort.com J � , Sure O • Air Conditioners Accessories Model No. SA1618 SA1624 SA1630 SA1636 SA1642 SA1648 SA1660 Compressor crankcase heater' 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Freeze Stat 50313 50313 50313 50313 50313 50313 50313 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 Heat pump Riser 6In. 686020 686020 686020 686020 686020 686020 686020 Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200R03T3TVLC 200RD3T3TVLC (24 VAC,50/60 Hz) Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (120/240 VAC,50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 'Crankcase Heater recommended with Low Ambient Kit. Weighted Sound Power Level (NA) Unit Size-Voltage,Series Standard TYPICAL OCTAVE BAND SPECTRUM(dBA without tone adjustment) Rating(dBA) 125 250 500 1000 2000 4000 8000 SA1618A 76.6 53.4 60 65.7 66.3 64.2 58.8 52.6 SA1624A 75.5 49.9 58.4 61.4 64.1 61.6 57.3 50.8 SA1630A 74.3 48.4 57.4 62.6 64.5 61.5 56.5 51.5 SA1636A 75 51.6 58.7 63.1 66.1 62.3 59 55.7 SA1642A 70.7 47.5 51 60.2 60.7 59.7 53.6 50.4 SA1648A 74.3 51.2 56.1 64.5 65.6 60.7 56.6 52.6 SA1660A 74.6 50.1 55.1 65.6 64.8 1 63.2 57.4 1 56.4 NOTE:Tested in accordance with AHRI Standard 270-08(not listed in AHRI) www.SureComfort.com 9 „ Sure Cornforte i • Air Conditioners Unit Dimensions OPERATING SHIPPING MODEL H(Height) L(Length) W(Width) H(Height) L(Length) W(Width) NO. INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm SA1618A 27 685 29.75 755 29.75 755 27.375 695 32.25 819 32.25 819 SA1624A 27 685 33.75 857 33.75 857 27.375 695 36.25 921 36.25 921 SA1630A 27 685 35.75 908 35.75 908 27.375 695 38.25 972 38.25 972 SA1636A 31 787 33.75 857 33.75 857 31.375 797 36.25 921 36.25 921 SA1642A 39 990 35.75 908 35.75 908 39.375 1000 38.25 972 38.25 972 SA1648A 45 1143 35.75 908 35.75 908 45.375 1153 38.25 972 38.25 972 SA1660A 51 1295 35.75 908 35.75 908 51.375 1305 38.25 972 38.25 972 ALLOW OVER HANG CLEARNACE OF 60"[1524 mm]MIN. W L H SERVICE PANELS/ INLET CONNECTIONS/ HIGH R LOW VOLTAGE ACCESS AIR INLET GRILLE ALLOW 24”[610 mm]MIN. ALLOW 6"[152 mm]MIN.CLEARANCE CLEARANCE ALL SIDE 12'[305 mm]RECOMMENDED [ ]Designates Metric Conversions ST-A1226-24-00 10 www.SureComfort.com CLEARANCES in c 0 WALL WALL , 0 3 6" o (152.4) 24" r" (609.6) c Service 3 24" 12" 12" v (609.6) (304.8) (304.8) Service 6" (152.4) 6" (152.4) 12" (304.8) WALL 24" 24" 24" (609.6) (609.6) (609.6) Service Service Service 18" 24" 2411 (457.2) (609.6) (609.6) 24" recommended 24" recommended 6" minimum 6" minimum NOTE: NUMBERS IN () = mm IMPORTANT When installing multiple units in an alcove,roof well or partially enclosed area,ensure there is adequate ventilation to prevent recirculation of discharge air. ST-A1225-01-00 Sure Comfort@Conditioners Control Wiring FIGURE 2 *IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED,IT IS RECOMMENDED THAT CONTROL WIRING FOR GAS OR OIL FURNACE W1(WBK)AND W2(W/BL)BE JUMPERED TOGETHER. TYPICAL THERMOSTAT TYPICAL THERMOSTAT FOR TYPICAL GAS OR OIL HEAT SUBBASE FOR TYPICAL ELECTRIC HEAT SUBBASE OO © ® ® y r R BR-BROWN WIRE YL-YELLOW WIRE BR-BROWN WIRE X-WIRE CONNECTION R-RED WIRE YL-YELLOW WIRE WBK-WHITE WIRE WITH BLACK STRIPE GBK-GREEN WIRE WITH BLACK STRIPE PU-PURPLE WIRE(NOT USED) X-WIRE CONNECTION TYPICAL GAS OR TYPICAL ELECTRIC HEAT OIL FURNACE LOW VOLTAGE JUNCTION BOX * W/BL TYPICAL CONDENSING R TYPICAL CONDENSING R UNIT UNIT X W/BK G/BK YL Y YL YL BR BR BR - Pu_ Application Guidelines 1.Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01 -in.wc. 2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F(12.8°C). 3. Maximum outdoor operating air temperature is 125°F(51.7°C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Use only copper wire for electric connections at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory—supplied filter drier must be installed. 12 www.SureComfort.com Refrigerant Line Size Information Liquid Line Selection Chart c Liquid Line Size Elevation(Above or Below)Indoor Coil R-410A System Connection Size Liquid Line Size Total Equivalent Length-Feet[m] n Capacity Model (Inch I.D.)[mm] (Inch O.D.)[mm] 25[7.62] 50[15.24]175[22.86] 100[30.48] 125[45.72] 1150[45.72] 1175[53.34] 200[60.96] 1225[68.58] 250[76.20] 275[83.82] 1300[91.44] 0 3 Maximum Vertical Separation-Feet[m] 0 1/4 [6.35] 25[7.62] 50[15.24] 60[18.29] 45[13.72] 30 [9.14] 15 [4.57] WR N/R N/R N/R N/R WR '* 5/16 [7.94] 25[7.62] 50[15.24] 75[22.86]1 85[25.91] 85[25.91] 80[24.38] 75[22.86] 70[21.34] 70[21.34] •65[19.81] 60[18.29] 55[16.76] 0 18 3/8°[9.53] 3/8 [9.53] 25[7.62] 50[15.24] 75[22.86] 95[28.96] 95[28.96] 95[28.96] 90[27.43] 90[27.43] '90[27.43] 90[27.43] 85[25.91] 85[25.91]- 7/16[11.12] 25[7.62] 50[15.24] 75[22.86] 100[30.48 1100[30.48] 100[30.48] 100[30.48] 95[28.96] 95[28.96] 95[28.96] 95[28.96] 95[28.96] 1/2[12.71] 25[7.62] 50[15.24] 75[22:86] 100[30.48] 100[30.48] 100[30.48] 100[30.48] 100[30.48] 100[30.48] 100[30.48] 100[30.48] 100[30.48] 1/4 [6.35] 25[7.62] 50[15.241 35[10.67] 10 [3.05] N/R N/R WR N/R N/R N/R N/R N/R 5/16 [7.94] 25[7.62] 50[15.24] 75[22.86] 80[24.38] 75[22.86] 70[21.34] 60[18.29] 55[16.76] 50[15.24] 45[13.72] 40[12.19] ,30 [9.14] 24 3/8°[9.53] 3/8 [9.53] 25[7.62] 50[15.24] 75[22.86] 95[28.96] 95[28.96] 90[27.43] 90[27.43] 90[27.43] 85[25.91] 85[25.91] 80[24.38] 80[24.38] 7/16[11.12] 25[7.62] 50[15.24] 75[22.86] 100[30,48] 100[30.48] 100[30.48] 100[30.48] 100[30.48] 95[28.96] 95[28.96] 95[28.96] 95[28.96] 1/2[12.71] 25[7.62] 50[15.24] 75[22:86] 100[30.48] 105 [32] 100[30.48] 100[30.48] 100[30.48] 100[30.48] 100.[30.48] 100[30.48] 100[30.48] 1/4 [6.35] 25[7.62] 30 [9.14] N/R N/R N/R N/R WR N/R N/R N/R N/R WR 5/16 [7.94] 25[7.62] 50[15.24] 70[21.34] 65[19.81] 55[16.76] 45[13.72] 35[10.67] 25 .[7,62] 20 [6.1] 10 [3.05] N/R WR 30 3/8°[9.53] 3/8 [9.53] 25[7.62] 50[15.24] 75[22.86] 85"[25.91.] 85[25.91] 80[24.38] .80[24.38] 75[22.86] 70[21.34] 70[21.34] 65[19.81] 60[18.29] 7/16[11.12] 25[7.62] 50[15.24] 75[22.86] 95[28.96] 95[28.96] 90[27.43] 90[27.43] 90[27.43] 90[27.43] 85[25.91] 85[25.91] 85[25.91] 1/2[12.71] 25[7.62] 50[15.24] 75[22.86] 95[28.96] --95[28.96] 95[28.96] 95[28.96] 95[28.96] 95[28.96] 95[28.96] 95[28.96] '90[27.43] 1/4 [6.35] 25[7.62] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R WR 5/16 [7.94] 25[7.62] 50[15.24] 60[18.29] 45[13.72] 35[10.67] 20 [6.11 5 [1.52] N/R N/R N/R N/R N/R 36 3/8°[9.53] 3/8 [9.53] 125[7.62] 50[15.24] 75[22.86] 80[24.38] 75[22.86] _70[21.34] 65[19.81] 60[18.29]- 60[18.29] '55[16.76] 50[15.24] 45[13.72] 7/16[11.12] 25[7.62] 50[15.24] 75[22.86] 90[27.43] 90[27.43] B5[25.91] . 85[25.91] 85[25.91] 80[24.38] 80[24.38] 75[22.86] 75[22.86] 1/2[12.71] 25[7.62] 50[15.24] 75[22.86] 95[28.96] 95[28.96] 95[28.96] 90[27.43] 90[27.43] 90[27.43] 90[27.43] 90[27.43] 85[25.91] 1/4 [6.35] 25[7.62] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R WR 5/16 [7.94] 25[7.62] 50[15.24] 55[16.76] 45[13.72] 30 [9.14] '15 [4.57] N/R N/R N/R N/R N/R N/R 36B 3/8°[9.53] 3/8 [9.53] 25[7.62] 50[15.24] 75[22.86] 80[24.38] 75[22.86] 70[21,34] 65[19.81] 60[18.29] 55[16.76] 50[15.24] 45[13.72] 40[12.19] 7/16[11.12] 25[7.62] 50[15.24] 75[22.86] 90[27.43] 90[27.43] 90[27A3] 85[25.91] 85[25.91] 80[24.38] 80[24.38] ,75[22.86] 75[22.86] 1/2[12.71] 25[7.62] 50[15.24] 75[22:86] 95[28.96] 95[28.96] 95[28.96] 95[28.96] 90[27.43] 90[27.43] 90[27.43] 90[27.43] 90[27.43] 1/4 [6.35] 20 [6.1] N/R N/R N/R N/R N/R WR N/R N/R N/R N/R N/R 5/16 [7.94] 25[7.62] 50[15.24] 40[12.19] 20 [6.1] N/R N/R N/R N/R N/R N/R N/R WR 42 3/8°[9.53] 3/8 [9.53] 25[7.62] 50[15.24] 75[22.86] 70[21.34] 60[18.29] 55[16.76] 50[15.24] 45[13.72] 40[12.19] 30 [9.14] 25 [7.62] 20 [6.1] 7/16[11.12] 25[7.62] 50[15.24] 75[22.86] 85[25.91] 80[24.38] 80[24,38 75 22.86] 70[21.34] 70[21.34] 65[19.81] 65[19.81] .60[18.29] 1/2[12.71] 25[7.62] 50[15.24] 75[22.86] 90[27.43] 85[25.91] 85[25.91] 85[25.91] 85[25.91] 80[24.38] 80[24.38] 80[24.38] 80[24.38] e 1/4 [6.35] 15[4.57] N/R N/R N/R N/R N/R WR N/R N/R N/R N/R N/R 5/16 [7.94] 25[7.62] 50[15.24] 35[10,67] 15 [4.57] N/R N/R N/R N/R N/R N/R N/R N/R 48 3/8°[9.53] 3/8 [9.53] 25[7.62] 50[15.24] 75[22.86] 65[19.81] 60[18.29] 55[16.76] 45[13.72] 40[12.19] 30 [9.14] 25 [7.62] 20 [6.1] 10 [3.05] 7/16[11.12] 25[7.62] 50[15.24] 75[22.86] 85[25.91] 80[24.38] 80[2438] 75[22.86] 70[21.34] 70[21.34] 65[19.81] 65[19.81] 60[18.29] 1/2[12.71] 25[7.62] 50[15.24] 75[22.86] 90[27.43] 90[27.43] 85[25.91] 85[25.91] 85.[25.91] 85[25.91] 80[24.38] 80{24.38] 80[24.38] 1/4 [6.35] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R WR 5/16 [7.94] 25[7.62] 30 [9.14] N/R N/R N/R N/R N/R N/R N/R N/R N/R WR 60 3/8°[9.53] 3/8 [9.53] 25[7.62] 50[15.24] 60[18.29] 50[15.24] 40[12.19] 30 [9.14]- 20 [6.1] 5 [1.52] N/R N/R N/R N/R 7/16[11.12] 25[7.62] 50[15.24] 75[22.86] 70[21.34] 70[21.34] 65[19.81] 60[18.29] 55[16.76] 50[15.24] "45[13.72] 40[12.19] 40[12.19] 1/2[12.71] 25[7.62] 50[15.24]175[22.86] 80[24.38] 80[24.38] 75[22.86] 75[22.86] 75[22.86] 70[21.34] 70[21.34] 65[19.81] 65[19.81] NOTES: [ ]Designates Metric Conversions N/R =Application not recommended. w Grey=This application is acceptable,but the long line guidelines must he followed. Reference Long Line Set section in the IN Refrigerant Line Size Information (con't.) Vapor Line Selection Chart R-41 CA System Vapor Line Vapor Line Size Capacity Multiplier Table Capacity Model Connection Size (Inch O.D.)[mm] Total Equivalent Length Feet[m] (inch I.D.)[mm] 25[7.62]150[15.24] 75[22.86] 100[30.48] 125[45.72]1150[45.72]1175[53.34]1200[60.96]1225[68.58] 250[76.20] 275[83.82] 300[91.44] 5/8[15.88] 1.00 0.99 1 0.99 0.99 0.98 0.98 0.97 0.97 0.97 0.96 0.96 0.96 3/4[19.05] 1.00 1.00 1.00 0.99 1.00 1.00 0.99 0.99 0.99 0.99 0.99 0.99 18 3/4°[19.06] 7/8[22.23] N/R N/R N/R N/R WR N/R N/R N/R N/R N/R N/R N/R 1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R WR N/R N/R N/R 1-1/8[28.58] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 5/8[15.88] 1.01 0.99 0.98 0.98 0.97 0.96 1 0.95 0.95 0.94 1 0.93 0.93 0.92 3/4[19.05] 1.00 1.00 1.01 0.99 0.99 1.00 0.98 0.98 0.98 0.98 0.98 0.98 24 3/4"[19.06] 7/8[22.23] 1.00 1.01 1.00 1.00 1.00 1.01 1.00 1.00 1.00 0.99 0.99 1.00 1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R WR N/R N/R N/R 1-1/8[28.58] N/R N/R N/R N/R N/R N/R N/R N/R WR N/R N/R N/R 5/8[15.88] 1.01 0.99 0.98 0.97 0.96 0.95 0.95 0.94 0.93 0.92 0.91 0.91 3/4[19.05] 1.00 1.01 1.01 1.00 1.00 1 0.99 0.99 0.98 0.98 0.98 0.97 0.97 30 3/4°[19.06] 7/8[22.23] 1.01 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.00 1.00 1.00 1.00 1 [25.4] 1.01 1.01 1.01 1.00 1.00 1.01 1.00 1.01 1.00 1.00 1.00 1.00 1-1/8[28.58] N/R N/R N/R N/R N/R N/R N/R N/R WR N/R N/R N/R 5/8[15.88] 0.99 0.97 0.95 0.94 0.93 0.93 0.91 0.91 0.90 0.89 0.87 0.86 3/4[19.05] 1.00 0.99 0.99 0.98 0.98 0.97 0.96 0.96 0.95 0.95 0.94 0.94 36 3/4°[19.06] 7/8[22.23] 1.00 1.00 0.99 1.00 0.99 0.99 0.99 0.98 0.98 0.98 0.97 0.97 1 [25.4] 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.99 1-1/8[28.58] 1.01 1.01 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 5/8[15.88] 1 0.99 0.97 0.97 0.94 0.94 0.93 0.92 0.90 0.89 0.87 0.87 0.85 3/4[19.05 1 1.00 1.00 0.99 0.99 0.98 0.98 0.97 0.97 0.97 0.95 0.95 0.95 36B 3/4°[19.06] 7/8[22.23] 1.01 1.00 1.00 1.00 1.00 0.99 1.00 1.00 0.99 0.99 0.99 0.98 1 [25.4] 1.01 1.01 1.00 1.00 1.01 1.00 1.01 1.00 1.00 1 1.00 1.00 1.00 1-1/8[28.58] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 5/8[15.88] 0.98 0.97 0.95 0.92 0.91 0.90 0.89 0.86 0.85 0.84 0.83 0.83 3/4[19.05] 1.00 0.98 0.98 0.97 0.96 0.96 0.95 0.95 0.93 0.93 0.93 0.92 42 7/8"[22.23] 7/8[22.23] 1.00 1.00 0.99 0.99 0.98 0.98 0.98 0.97 0.97 0.96 0.96 0.96 1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 1-1/8[28.58] N/R N/R N/R N/R N/R N/R N/R N/R WR N/R N/R N/R 5/8[15.88] 0.98 0.97 0.94 0.92 0.91 1 0.89 0.87 0.86 0.84 0.83 0.82 0.81 3/4[19.05] 1.00 0.99 0.98 0.97 0.97 0.96 0.96 0.95 0.94 0.94 0.93 1 0.92 48 7/8°[22.23] 7/8[22.23] 1.00 1.00 1.00 1.00 0.99 0.98 0.98 0.98 0.98 0.98 0.97 0.97 1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R in 1-1/8[28.58] N/R N/R N/R N/R N/R N/R N/R N/R WR N/R N/R N/R 5/8[15.88] 0.98 0.95 0.92 0.88 0.88 0.86 0.85 0.82 N/R N/R N/R N/R fD 3/4[19.05] 1.00 0.99 0.98 0.97 0.96 0.95 0.94 0.94 N/R N/R N/R N/R 3 60 7/8"[22.23] 7/8[22.23] 1.01 1 1.00 1.00 1.00 0.99 1 0.99 0.98 0.97 1 WR N/R N/R N/R 0 1 [25.4] 1.02 1.01 1.01 1.00 1.00 1.01 0.99 1.00 WR N/R N/R N/R h 1-1/8[28.58] N/R N/R N/R N/R N/R N/R N/R N/R WR N/R N/R N/R it NOTES: [ ]Designates Metric Conversions s r O N/R=Application not recommended. All calculations assume a 3/8"liquid line i PER FORMAN CE.P.1 '"INUM. -. r. ee 777 The new degree of comfort® PERFORMANCE PLATINUM T' Gladiator high efficiency electric water heaters are engineered for longer life with built-in leak detection and auto water shutoff Smart Technology Performance 71 ® FHR:55-72 gallons, based on �. gallon capacity ®Recovery:21 to 25 GPH at a 90°F ®Integrated leak detection and rise,depending on model** prevention system with factory M Self cleaning fights installed auto water shut-off valve sediment build-up to limits leaks to no more than 20 prolong tank life and ., ounces of water' maintain efficiency and ®LeakSense'"Built-in Leak Detection tank capacity System detects any leak large or Longer Life small, internal or extema12 ®Premium grade anode rod provides long-lasting tank protection 1L.P. CONet' Features ®High performance and lower ®Built-in EcoNet®WiFi technology for operating cost temperature control and immediate notification about leaks and service ®Compliant with many electric utility needs from anywhere3 incentive programs 11 Know before hot water runs out with ®Electric junction box located above the Hot Water Availability Indicator in heating elements for easy installation the EcoNet®app3 ®Over-temperature protector cuts Hands-free voice control with Alexa off power in excess temperature and Google Nest to easily adjust set situations temperature° Plus... ®Element Health Indicator shows ®Temperature and pressure relief exactly which element needs to be valve included PERFORMANCE PLATINUM replaced and when3 .,,,, Warranty Gladiator High Efficiency Easy to Install and Service ®12-Year limited warranty for tank 40, 50 and 55-Gallon Capacities ®Diagnostic mode gives diagnostic info and parts,3-year full in-home labor 240 Volt AC/Single Phase while at the water heater to expedite warranty* services See written warranty for complete details O Durable brass drain valve helps I drain the tank faster to reduce time Units meet or exceed ANSI requirements and have on the job been tested according to D.O.E.procedures.Units meet or exceed the energy efficiency requirements Efficient of NAECA,ASHRAE standard 90,ICC Code and all Efficiency state energy efficiency performance criteria. ®.92-.93 UEF UL ®Dual 4500 or 5500 watt stainless `®"°'"``1 steel heating elements See specifications chart on back. 07/19 FORM NO.THD-PPEG12 Rev.1 T 1 1 The new degree of comfort' Gladiator'" • •- atiohs Nominal Rated Recovery Flrst Heur Tank HL to Gullet Ht to INet Shlp Uniform Gallon . Gallon Model In G.P.H. RaOng Helli Water Cann. Water Cann. mote, Weigh Energy Factor Fuel Typo Description Capaclty Capacity _ Number 90•F Rise G.P.H. A B C D (LBS) (UEF) . With PlusOne'"Management System Eleotrlc Tall 55 55 XE55T12CS55U0 25 72 57 59-3/4 61-3/4 22-1/4 130 0.92 'Electric Tall 55 55 XE55T12CS451.10 21 72 57 59-3/4 61-3/4 22-1/4 130 0.92 Electric . Tall 50 45 XE50T12CS55U1 25 63 58-3/8 61-5/8 63-5/8 20-1/4 123 0.92 Eieodc Tall 50 45 XE50T12CS45U0 21 63 58-3/8 61-5/8 63-5/8 20-1/4 123 0.92 'Electric Medium 50 45 XE50M12CS55U1 25 63 48 50-1/2 52-1/2 22-1/4 129 0.92 Electric Medium 50 45 XE50M12CS45U0 21 63 48 50-1/2 52-1/2 22-1/4 129 0.92 "Electric Medium 40 36 XE40M12CS55U1 25 55 48-3/8 50-1/2 52-1/2 20-1/4 108 0.93 ' Electric Medium 40 36 XE40M12CS45U0 21 55 48.3/8 50-1/2 52-1/2 20-1/4 108 0.93 Uniform Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements. •Heaters furnished with standard 240 volt AC,single phase non-simultaneous wiring,and 4500 or 5500 watt upper and lower heating elements. "Recovery=wattage/2.42 x temp.rise°F. Example: 550OW =25 GPH a^i 2.42 x 90° HOT WATER ® COLD WATER -Recovery calculations used are based on 5500 watt elements used in non-simultaneous operation. CONNECTION CONNECTION ANODE ROD O A WATER CONNECTIONS ALL 314°N.P.T. 'Source:Rheem Leak-Sensing Data,testing under a vacuum lock using 50-gallon tank,no expansion tank,average tank pressure of 40 psi,assuming no additional faucets are opened.2Water leaks from the heater only,as tested across scenarios including a minimum of 5.5mL/hr volume leak rate,using most common installation scenan.as. 3W0 broadband connection and EccNet®App required;connection between water heater and app dependent on externa/factors beyond Rheem's control.4Amawn Alexa and Google Nest devices sold separately.Amazon,Alexa and all related logos are trademarks ofAmawn.com,Inc.or its affiliates.Google is a trademark of Google LLC. 'WiFt broadband connection and Rheem Contractor App required;connection between water heater and app dependent on external factors beyond Rheem's control. In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice, Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100 Roswell,Georgia 30076 • www.rheem.com 07/19 FORM NO.THD-PPEG12 Rev.t