HomeMy WebLinkAbout1000-126.-6-18 .ryRECEIVED FOR INTERNAL USE ONLY
JG 3 0 201 ATION
� hol =�own: SITE PLAN USE DETE
E. �N
Planning Board
Initial Detern ination
nor �I
Date Sent:A -21-i-L
�/Date
Project-Narne:—Parz�,DL:�D�
Project Address:—AL2 ����`.�.�.... ....,.��.. �.-�..
.
2G honing D1st�rlc(:�
Suffolk County Tax Map No.:1 Cl9-� - -- - i
Suff �"
Request: xx .. .
plication and supporting documen(at"ton,as to
(Note: Copy of Building Permit
,proposed use or uses should be submitted.)
-Initial Determination as to whether use is permitted:_
ete.rmination as to whether site plan is required:
Initial D
g 1 �
. � �
Signet 111sp or
planning Department (P.D.) Referral:_
� P..D. Date Received: _ l
Date of Coy Intent:
Comments:.. ,
tic
o e C
s � o� .c Signature�16n�lngt.w e viewer
17 J,
`lnal l F'tE 1'I"n l�wlat 011
Date:--j—/-
Decision:
ate: j=Decision:
c%,nntitra of Rididina InGnPctnr
LI ; R,, L. K. McLean Associates P. C.
437 South Country Road • Brookhaven New York • 11719 CONSULTING ENGINEERS
(631)286-8668 • FAX(631)286-6314 • ]kma@]kma.com
Associates
RAYMOND G.DiBIASE,P.E.,PTOE,PTP,PRESIDENT and CEO CHRISTOPHER F.DWYER
ROBERT A.STEELE,P.E.,EXECUTIVE VICE PRESIDENT JAMES L.DeKONING,P.E.
STEVEN W.EISENBERG,P.E.
ANDREW B.SPEISER
MATTHEW C.JEDLICKA,LEED AP
KEITH J.MASSERIA,P.E.
VINCENT A.CORRADO,P.E.
August 15, 2019
Town of Southold Building Dept.
54375 Main Rd.
P.O. Box 1179
Southold,NY 11971
RE: Veterans Memorial Park
Mattituck,New York
LKMA No. 17107.000
To whom it may concern:
As Consulting Engineers for Mattituck Park District, we are submitting, on their behalf, an application for
a Building Permit to construct a new 10'-6" x 23'-8" comfort station. Enclosed herewith for your review,
please find the following:
• Building Permit Application
• Stormwater Management Work Sheet
• Stormwater Management Plan
• Survey
• Site Plans
• Kodiak Precast Building Plans-
• Precast Design Calculations
• Interior Lighting Compliance Certificate
• NYSDEC Wetlands Permit
• Southold Trustees Permit
• SCDHS Sanitary Permit
If you have any questions or require additional information,please contact this office.
Very truly yours,
CFD:mf Christopher F. Dwyer,Associate
L. K. McLean Associates, P.C.
Enc. (11)
Cc: Mattituck Park District, w/enc.
LKMA File Copy w/enc.
• Founded in 1950 •
TOWN OF SOUTHOLD BUILDING--RMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do yuu have or need the following,before applying?
TOWN HALL Board of Health SCDHS(Wastewater)
SOUTHOLD,NY 11471 4 sets of Building Plans X
TEL: (631)765-1802 Planning Board approval
FAX: (631)765-9502 Survey X
Southoldtownny.gov PERMIT NO. Check
Septic Form
N.Y.S.D.E.C.X
Trustees X
C.O.Application
Flood Permit
Examined 20 Single&Separate
Truss Identification Form
Storm-Water Assessment Form x
Contact:
Approved 20 Mail to:
Disapproved a/c
Phone:
E,3 too
L =U
Building Inspector
t AUG 1 9 2019 APPLICATION FOR BUILDING PERMIT
BUJI DING IIF Date July 23 >2019
I"` 1J) INSTRUCTIONS
a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans,accurate plot plan to scale.Fee according to schedule.
b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas,and waterways.
c.The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an
addition six months.Thereafter,a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or
Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The
applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signature of allplicant oiQriame.if a corporation)
P.O.Box 1413,Mattituck,NY 11952
(Mailing address of applicant)
State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder
Agent
Name of owner of premises Mattituck Park District
(As on the tax roll or latest deed)
If applicant is a corporation,signature of duly authorized officer
Doris McGreevy,Co Chair
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No,
1. Location of land on which proposed work will be done:
11280 Peconic Bay Blvd Mattituck
House Number Street Hamlet
County Tax Map No. 1000 Section 126 Blocks Lot 18
Subdivision N/A Filed Map No.NIA Lot NIA
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy Wood Framed Storage Shed
b. Intended use and occupancy 1 Story 250sf Slab on Grade comfort station
3. Nature of work(check which applicable):New Buildingx Addition Alteration
Repair Removal Demolition Other Work
(Description)
4. Estimated Cost Fee ($100.00+($0.40*250SF))=$200.00
(To be paid on filing this application)
5. If dwelling,number of dwelling units N/A Number of dwelling units on each floor N/A
If garage, number of cars NIA
6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. Municipal/comfort Station
7. Dimensions of existing structures,if any:Front 14.4' Rear 14.4' Depth 10.3'
Height 15' Number of Stories'
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8. Dimensions of entire new construction:Front 10'-6" Rear 10'-6" Depth 2S-B"
Height 10'-2" Number of Stories 1
4. Size of lot:Front 604.24' Rear 548-11' Depth 525.78'
10.Date of Purchase Name of Former Owner
11.Zone or use district in which premises are situated Protected
12.Does proposed construction violate any zoning law,ordinance or regulation?YES NO x
13.Will lot be re-graded?YES NO x Will excess fill be removed from premises?YES NO x
14.Names of Owner of premises Mattituck Parte District Address Po Box 1413,Mattituck,NY 11952 Phone No, 631-298-9103
Name of Architect LK McLean Associates P.C. Address°7 Sou`"c°""`n Rd.B`°°"",NY 11719 Phone No 631-268-8668
Name of Contractor Address Phone No.
15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES x NO
*IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED.
b.Is this property within 300 feet of a tidal wetland?*YES x NO
*IF YES,D.E.C.PERMITS MAY BE REQUIRED.
16.Provide survey,to scale,with accurate foundation plan and distances to property lines.
17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey.
18.Are there any covenants and restrictions with respect to this property?*YES NO x
*IF YES,PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY OF 1
Day-1.5 me 6,r4Cv y being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)He is the A 6-e yr
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be
performed in the manner set forth in the application filed therewith.
i
before me this
day of 20�q
ubI Signature of Appy
ntunoa altoHeS !F*
---.a" 72116f'1.
r
CO check Software Version CO check- eb
Interior Lighting Compliance Certificate
e
"1
Project Information
Energy Code: 2012 IECC
Project Title: Kodiak KD-103
Project Type: New Construction
Construction Site: Owner/Agent: Designer/Contractor:
Additional Efficiency Package(s)
Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations.
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2
1-Workshop
2-Office 203 0.85 173
Total Allowed Watts= 227
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixture Watt.
y1!V�;ark p
LED:C:Other: 1 1 28 28
2-Office
LED:A:Other: 1 4 28 112
Total Proposed Watts= 140
Me liiiiiiiijillilfilliim
Interior Lighting Compliance Statement
Compliance Statement. The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been
designed to meet the 2012 IECC requirements in COMcheck Version COMcheck-Web and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Name-Title-WW Sign ature.......W Date p
01F
t W4 � ^
__...._ ..._._....._....._._. nA
www ._www_
Project Title: Kodiak KD-103 _ Report date: 06/12/19
Data filename: Page 1 of 7
dtt a 16 2019
CO check Software Version CO chleck-Web
Exterior Lighting Compliance Certificate
Project Information
Energy Code: 2012 IECC
Project Title: Kodiak KD-103
Project Type: New Construction
Exterior Lighting Zone 3(Other)
Construction Site: Owner/Agent: Designer/Contractor:
Allowed Exterior Lighting Power
A B C D E
ArealSurface Category Quantity Allowed Tradable Allowed Watts
Watts/ Wattage (B X C)
Main...es..ft of doorw�w 30_ MYes..w�� mm_M 180
Total Tradable Watts(a)= 180
Total Allowed Watts= 180
Total Allowed Supplemental Watts(b)= 750
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 750 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixture Watt.
LED:B:Other: 1 2 14 28
Total Tradable Proposed Watts= _ 28
Exterior Lighting t�ornpliance Statement
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application.The proposed exterior lighting systems have been
designed to meet the 2012 IECC requirements in COMcheck Version COMcheck-Web and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Name-Title m� � Signatures
ci�- N�
AM
ik�'
Project Title: Kodiak KD-103 Report date: 06/12/19
Data filename: ne 1 ,2019 Page 2 of 7
COMcheck Software Version COMcheck-Web
A Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided,
section
# Plan Review Complies? Comments/Assumptions
&
item,q�L.,
Elcomplie
C103.2 :Plans, specifications, and/or s
[PR4]1 :calculations provide all information ;ODoes Not
,with which compliance can be I
!determined for the interior lighting ![]Not Observable,
and electrical systems and equipment []Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include Interior
,lighting power calculations,wattage of
bulbs and ballasts,transformers and a
control devices.
. ..... .
.. ..—1......w._................... ..................... .........
C103.2 Plans, specifications, and/or 'DComplies
[PR8]1 :calculations provide all information DDoes Not
with which compliance can be
'
:determined for the exterior lighting []Not Observable
and electrical systems and equipment :F-]Not Applicable
and document where exceptions to
the standard are claimed. Information
.provided should include exterior
,lighting power calculations, wattage of,
bulbs and ballasts,transformers and
,,control devices.
Additional Comments/Assumptions:
of N EeF
4
F
J1 16 019
F�JEig:lhjrr�ac��( Ier�1 -1,1-3Medium Im act 2) "r 3) —
Project Title: Kodiak KD-103 Report date: 06/12/19
Data filename: Page 3 of 7
."'rection ._.._....._......_............_..._.,_.. �.�., _ ._...�
# Rough-In Electrical Inspection Complies? Comments/Assumptions
`;Automatic controls to shut off all Mµ [. Complies
t building lighting installed in all ❑poes Not
❑Nat Observable
❑Not Applicable
1 5
peraPProved ilightingtin ......_..... .wv..._.om
Independent lighting controls installed ❑Complies
e plans and all ❑Does Not
manual controls readily accessible and;
visible to occupants. ❑Nat Observable'
_ ❑Not Applicable
C405.2.1, m!Lighting g ting controls installed to uniformly ,❑Complies � . ..._......�...__.........w.._....._�._...�.__ww.__w.___,...._._
.._. ._.._ .......w.
2 reduce the lighting load by at least ❑Does Not
[EL15]1 150%.
`❑Nat Observable
'❑Nat Applicable
i) „ r
Daylight
Day g zones provided with Elcomplies s
individual controls control Does Nct
lights independent og are
;❑Not Observable
�.., dlighting.
❑Not Applicable
...,w... _.,_ �..,.
0405.2:3 ,Sleeping units have at least one ❑Complie _...
s
[ELVJ amaster switch at the main entry door '❑Does Not
Jhat controls wined luminaires and
switched receptacles. ❑Not Observable
_ ❑Not Applicable
C405.2.2. s ...w..._ ....__.._.. wµ_.._ _....._ ...__... _ w_ _.�u_ .... _ ........
sOccupancy sensors installed in i❑Complies
2 :required spaces. �❑Does Not
[EL18]1
[]Not Observable,
❑Not Applicable
C405.2.2. Prim..ary.sid.e.igh_.. _......................................w...,...,.. ❑Cam
lted areas are,,.�.�.�.�._...._.w�..� �................Rl,.i,es..,,,,,,,,,,,,,,,,,,,..�n� .._„_�._M..�................�w_...........��__..���..__wwww._....�._..�.�.�..__.M�.,,,,,,,,,,,,..�.�.�.�.�.�
3 equipped with required lighting j❑Does Not
[EL20]1 controls.
❑Not Observable
_ ;❑Nat Applicable
._..wwww_.............
0405.2.2. ;Enclosed spaces with daylight area ❑Complies ._Ma.....
3 under skylights and rooftop monitors ❑poes Not
[EL21]1 :are equipped with required lighting
controls. ';[:]Not Observable'
_ ❑Not Applicable
° Automatic lighting controls for exterior ❑Complies Rrt �WWW�..-.......
lighting installed. :❑Does Not
z� R
❑Not Observable
❑Not Applicable
0405.2.3 'Separate lightingcontrol devices for cttaN�* .�.�.w,,w. �....��...._,,,. .�...�_.. w ,_ �_...�.� _.............__..............www.�..__w__. _ .
[EL4]1 specific uses installed per approved ;❑Does Not
lighting plans. '❑Not Observable
_ ❑Nat Applicable _ ......._�_ ......www _............ NES
405. Fluorescent luminaires with odd ❑Complies ."
[E(J913 !numbered lamp configurations that !❑Does Not
:are within 10 feet center to center(if
recess mounted) or are within 1 foot '❑Nat Observable. co a
edge to edge(if pendant or surface :❑Not Applicable °° r'
„mounted)shall be tandem wired.
C405.4 Exit signs do not exceed 5 watts per ❑Complies
[EL6]1 face. ❑Does Not AN
;[]Nat Observable `'
'❑Nat Applicable
_.� ne 1, , 2019 _..�
. . ._w9._...m.................. ..._....._. ........_...... m Impact(Tier 2) _._m p
1 Hi h Impact Tier 1) 2 Mediu -�mpac _ 3 Low Im act(Tier 7 I
Project Title: Kodiak KD-103 Report date: 06/12/19
Data filename: Page 4 of 7
Rough-in Electrical Insp4ctlonComplies? Cornments/As!iumptions
C405.6 :Exterior grounds lighting over 100 W ElComplies
[EL24]1 :provides >60 Im/W unless on motion 'E:]DoesNot
,sensor or fixture is exempt from scope:
.of code or from external LPD. oNot Observable
;[]Not Applicable
............... . ..............
C405.2.3 Additional interior lighting power Ekornplies
[EL8]1 %allowed for special functions per the T]Does Not
$approved lighting plans and is
automatically controlled and '[]Not Observable
,separated from general lighting, !E]Not Applicable
Additional Comments/Assumptions:
of Ne
IAA4
co 4�1 4-
U 16, 19
g mpat(i=ier 1) ac
(Tier
..............
..........
Project Title: Kodiak KD-103 Report date: 06/12/19
Data filename: Page 5 of 7
FinalInspection Complies T Comments/Assumptions
FRe I� _p
C408,2.5. Furnished as-built drawings for 9.. Com lies._. _.,_x _._ .__.. .._.ww.._...... _.....M.mw..._w._ _._._. ......w _m.__
1 electric power systems within 30 days ❑Does Not
[ 11613 of system acceptance.
❑Not Observable
:❑Not Applicable
C3O� �........_._—_....__...w._ ._w �__M. ......_ .. ...... ....�.k ��.....aies ....................�
3.3, Furnished O&M instructions for ❑C m
0408.2.5, systems and equipment to the ❑Does Not
2 ;building owner or designated
[FI17}3 representative. ;❑Nat Observable
❑Not Applicable
... ...........www.
_._. _.................. .........
...,.....xture schedule for values.
[4055.2 pand
fixture
mplies
See the Iggfi
8] gn consistent what Does Not
ishowPothe apprapproved lighting q
:❑Not Observable
plans, demonstrating proposed watts
;are less than or equal to allowed ;❑Not Applicable
watts. _
6 2 Exterior lighting power is consistent flCd�mplies See the Interior Lighting fixture schedule for values.
�4095�6..www�. � � �� ����.�_....wfl , . ..-�._.,..�..,.._...�,.., ....�..,�Does Notw�..w. _.__�.�.�_....�.............��_�.www_...M.....��.__._........�..._�w._���..���_�.�_w.�._._�._......ww._...�._.�._.m.��.,,.a._��
h what is shown on the approved ;
,lighting plans, demonstrating
proposed watts are less than or equal ❑Not Observable
:to allowed watts. ;❑Nat Applicable
0408.3 .. _ w... .._......................_... ., _. __.M_ ._w ...w.._..... ....... ....... _ ._ ..... ......w. _ _...
Lighting systems have been tested to ❑Complies
[FI3311 ensure proper calibration,adjustment, :❑Does Not
programming, and operation. j❑Not Observable
❑Not Applicable
...., _
---------- ...............
Lighting systems
e shave been �Camplies
[F14811 enure proper calibration, adjustment,
...�w _...........ww.............. ..�.�...-_��ww__w
adjust ent, ;❑Does Not
programming, and operation.
❑Not Observable.
❑Not Applicable
Additional Comments/Assumptions:
NEAMS
f�
Il 6, 2 l
1 High„Impact(TierMl)M ._ Medium l.... (Tier 2) „Low Impact^(Tier 3)µ w„
Project Title: Kodiak KD-103 Report date: 06/12/19
Data filename: Page 6 of 7
Project Title: Kodiak KD-103 Report date: 06/12/19
Data filename: Page 7 of 7
30
CXT Inc. (Precast Div.) Kodiak KD-106 (NY) Page Dt
� Date:06/1144/201199
to
In-
Is(width of roof anal .� 11.92 8 Wv(tuw,q,i�Yk of vnaskl"'" fi',&1V'b
2G.6711 Wtrfrown( V'vmi+,k1� 1998014
Ar Area ofRaof �3IL71 ft^2 Ww(total walls enol wet d) 33225 lb
..",--
I1(hai toff buildin)
974 @ _ww '.Fw(�oo�nnel wei„�ht) ��- -----14985 lb M
'f,b llrnadr ok"But{dln) 2.3.4"l ft We�estunuedoCbiu'Id' 1 513190th
Wb(width of builq u 1 10,5 ft Waw ofl+ksda�aata'a�Sto a`Wd od"baoiq)dirq rwtiD wa�u91 68190lb
Ati(Area of buildin) 248.5471"2 PSFr aof snow++load 2 12M,f
Nw t t aM,u,utvdks 0 p^+SP(F'laor Live load' 400 sf
AvlK6!0-40 r Vow�m f,d s _...,,,,�0.00 ft-2 Finax(,Maxvnum a(}owabte ressure) 1500 f
Av(Arne of Vault) Og00 Et^2 Fu mw(Iv1WFRS U liEi Force)- 38 41.Mf Ww-
Vh faint height) Oft.__ ......._....... W'Lfat fl WF`R5 Yazeral vnn reussrey r 51.74psf
Cab(Closed Area of builduiE,) 7.37 22 RA2 s ecific weight of water)
Rw(dear,th of ftoodwater) i 0k **Wtight of vauh is twat r iderud in xtidi ng revisu m e
,6dduad P � MI4ga� Es L4 5--.1, t wimed' f,kRfia
CHECK SLIDING RESISTANCE
WWW 7 Verivelc tlgoan 4nas'oroia,acral s'is wrda snaw, 7202,2)b
Shear "......7 WfacNsmr�mic((rout sidsmmm aaonrf, wlthavt snaw 6023.3 ib
Vwi»d WLgaC*raaanat Wkn„I„iti*Fi 11929.2 Ib
1 xaad auz�yusgsrvrXymp per IBC I5(t„ri.3 toad combinations.
!�iChfiakflkaaislamwtc wikh 5m�ttorro ""'. .........m,,....YXide��,u” G V14 yn"7•„i*p±"F"m*Aw'b,,,, N49rdw 36B8,S,4i 6'kre
6&see
1yd
Factor of Safety Swa,�od now,Vwitad _ FSmvErwd�w 3.0...., � 1.0..
- Fsocesuauc,-P%hoo d V16a/lsntlid 1"etxroia"A 5.1 15^ 1 1,.0
%+"t(�-dta+wNsCaaarte�rrlaMktlWaSrndrrw�.�...r�.... N'as9a+9m�kr".6*'"4?b^m FsdirMe� tGl'.k"n%.6bU
F%raftl
Factor of Safety 1''Swind-pslidefVwind Fawtnd= 1.4 > L0
i'Ss ismri m Fs ,VlVsrisndr 'Fscnmuwlc 2.7
CHECK OVERTURNING RESISTANCE
She-
Loml+ uitirient per ISC 1605.3 Imut nwrnhinaa uw.
l')verlurniog Iteaivlaoce with �.�.-. .�.��..r •"�"':
Snow Otrsnow= ,G*We+.75'PSFr•Ar'(Wb/2 Dtrsuacv= 222852 ki ft
Fsr d
Fader of Safety FSweand,*C�bCrapaos+r'AC,M'w�i'sud I'"SwOnd� T.CMr ;+ 1,0
Ftisnixmds'+*ClcruoowfVstassrtzic I^�raasmuie� 3.4?i 1,0
l'lrverYurvmag Itesetaecs with 1Vo
Snmv .... Otr=6*We*Wb2 atr 214.,799ki ft
Fsr d
Faclarof Safety FSwind=0u,fVvind I Ftwbid L911 1
FSssdxwuo�*fdrrtV�nawxu6o Fse;smlc= 5,44 � 1.0
CHECK BEARING PRESSURE CONDITION
1aRa4f'wwsnrkre Font "+PSF'm'akrs.MMU)6',i fi 942,g5 fl",
L A""aWatWe
By observaum if the Imildingis placed on a propesiy Ga'lovn11 drairrod gians ra,sub-bare,die,dezi8n is sufficient baa
lateral and vertical loads.
CHECK BUOYANCY FORCE CONDITION
F'b*m w",Av*71vwr ww*'fm" 9,ww„Wta IFh =.I48Ryd.4'f71ip
Fanror^of Saat`aa __ FSPa�Wru F�b N;51r w 4,:Cri : ;�,„ I'SW1
The weight ofthe building exceeds the buoyant force due to hydrostatic pressure acting on the horizontal surface
of the vault,therefore,the design is sufficient against buaymncy,
Floor Design Information:
1)'Cbe tef`crenc`rA building is made of flood damage resistant 5000 psi reinforced concrete,
2)The vauft s)slem,if escisting,is designed to minimize infiltration into system and can be considered water tight
to aheight of 17”
3)Flood Ventilation is available at threshold level and flood ventilation exceeding 1"per sqft of floor area is provided
no more than 12"AF-F.
Page 28 of 30
CXT, Inc. (Precast Div.) Kodiak KD-106 (NY) Date:06/14/2019
P
d
._.... _....... Nin
1 3�
a1
� 8 p6 CY
mP.N
t
y
$mom �� dti
V
G
8^ Chi i en yf p n'.
P @$Tg °
. 'I ..
z „.
AT
1& 3
iJO
�I
CXT Inc. (Precast Div.) Kodiak KD-106 (NY) Page 26 of 30
� Date:06/14/2019
UE SILN(YN WALI.MARKED P12 au�.mmr a��C. shwa m�eapmxdu4aq�p mm_... .
. .. .... . . Kodiak K0.1.06 wok"Apr mmn¢r��+p Is1�e�w,dr ..._._
umw'w eww�w.'p Aanpr N,,ra mwraugay uwruyz:rrrmh,wm-.unP�`rumwJad.,wwva awmowur up�m�r,mr�s�u�mmrrmm�nu lmaar.�1 tl��,�asmua«aw�nr.rrrnwn6um�maM1r� a�r..c.:.,
.._,W..,,..,.w"""
G.xp
�a aia,w,Ws puu dww.uawv.�ry r3�,a�pl
b k dw Nmawwr 4.'p
Cdr a pa rgasw ..
<u Im,.
Ip2wA
a c t a ezonr 51"
MRh
"�" x"s�a6 ax da�.a,a a�aa.ro.a.r 'e-y—.aue a?r�m oe
Mtuu*wa aAGp n .+.r d rm .+xhd I§
{_._.. tl r�prma wnw;w.na x(u»ww ua t NaA
awrw, a m '�7ki4'N u�w u.r.: "' aq qu r%wwaam� �pP'�
mrd, "
i. .
axu»na C,a ;,,.r.W phi rx ax..m.a mV 91"a+nG
C:gmSI..
�._....�L .. .....,..,..,�,..�,.. ... ...., baaM1Ii
ru i s N w�.p fwwr a,,r a c a�.m s ro le m _
... ....
*���yyhn� as a asa � k�m�u�`p sanp arv�""
P,S
M.amu arwA iLar. m nHMM NAV aaya am,�" �wo;,wnaM"k2wspp¢x hp �' �m.+
aw.uM..ma saav Hb'
laaw.ppw .+auw.aw
�_ wws „aaaa,aauaanaw�,vwu�"w"_._,�..
�..,,. _. Maid."
_ "
��
�a , .
—0-Alln(Mad��i eu.uMpM
..�............... .,.,,,. W axa�
aaew�y"fl+c
....................._"""' p oaua^ :. .". aaa........ .�.w
.... ............M.. parr .......,,�.,. �.. ,,.,. .,...,.,,.�.,..,.,.,...,,.......... .. . .,..�,...,.�,
..
� gaxwa� wl,l� �a� a ah �� Lm mo
wa .""..." mm w ea u a a M as 6� a
p ha "......
a a.5 a ww�a aamnp
,..,rg�waaa��.mnuamm_IM,.�;w�rc�,awy ..�ro�fx w_ww.....
. w „... ... .w,W.._,....
pu3 Py rS.bAd umu+wSw xti a A M1a 0 0013 ••••••••••••••••,,••__•••'�frrol,"KK oV,a am,w°uXw••• aa,$.k nn x"" �i 24 ink• ••'
.-+.pL^K.ij.... axrpw��_ .. mMEAluw~
Ch.L 0M.>M. 0 x.. M
CXT, Inc. (Precast Div.) Kodiak KD-106 (NY) Page 24 of 30
Date:06/14/2019
,..".........._.__,,..
DESIGN OF WALL MAKFTD"_._.
r..wz.a
a^ _ p xw sound ud flax,rt maw ae reM.b&�w,54 rom;o wdk
C Nwuxm.. ............
..... ........ __........,.".,...�.�,..,,.w...........NM.~M rtm a www Mrw La.,'Nu d aar mdk„g 4 .....,,,
TMrvm "''mwe www+wama wwwap4 Yip aumm on mws ar�roand '".'"'" -„"'" mmx m r
_,..,_„
__.. _.... _.._..._... 'tlwwr rer
vwsw�s GaGa pinGwamwarm wpm .road l»nug�u�' r �
._.....a.,.._...,....._...... ..........
tkawdwwawm kMpw wN. .. ,...�. ,.,. -.......,..,....... - w
Gdua wnr aP nw m" K�urvk
a 9urrcwrFa„ �e' i�wY j.;ww�,, _._..._
vu ay au
-23,-M.N,A
.d
d wyS
,
....,..-,..,. a�'„a♦� � w:.a"d�wsuymu rerrsa.a c,m�u.Md %B. �
I................
_...,
�� uw7w�dk.a t w n cwamaw 'k rraaro r�" a m,+,�� A &ot tw,�,,,
_ m.a a w ww reaG.^� m � N1'SihW'm
,% .....p34
GNJ"5A' MIXacq'akawn q. ..__......��,.,,,µ.,�•.,.,. ,...,.,.......,»»....,.,,.�",.., ...,....,.,:.�...�.,...,.,..."....,..„................,...,.,.. .m..,�........"... C apN',w Btis Ub
...... ... .......... A`F
------------ w
_w..,..
"Y%'"f,n�u a5a•2.m° ""Cm �,Gan% to Fuk" "`GbS'w�w owwdu
AIM
dMx�MAC"7 »SA+a+Z+ .....�, µ d""""' G, w5`w ....,..
N w mdt s aLawa a' tnru � w ..._
_.............
....._........,.,..
�"�na "ika"
"6Ga wa« av�N„�"ax �»�a5 "✓w d ±r115"u�y
.........................
�.... www
�.w.wid44m4'.w�M1'3'"Nixi—W
„”"".wJk"d wb
..,.......,.....w." .........
.,.,.,..�..
�5 bYawTg,ya ua rr I K7tm G� E—z'
-�
"G"'"rrvW 14�Y m�n'tl d➢05% ""k A"�a wry A"fib µ" "�
:� .w__.w.. Nrw
........................"........._—%--Tor mNbl im.akn0••�J+aB'�5�q�a:2.. a�M%s �rc R"Nq"k kry kM••••
aa _ ar Maw �� �tB',
�' a� GaSYaw k rtm�awS""wk "
A W w.. 9......... ...
� pwm 4w wpm rmaY"cu vm�nat am,a5su .....w_.
...............
rmwSuc�a aa% wwwnarwz»rercar ouNNd7' _..
", Nr!wd,.n ua vawaaamdwwazu ea rnnu.i"' .. ""`""""`"""""aam w a,w nuwrtai m.wa a .xa ww"'s"'"""
.ia:�+��!,^�td�:
'.�mru5a+uuaNmuwwewu,m"aw„uumana ,........,, rauuararo
^^ ••- ,,•
OK,
C"L'&MosM.
Pagb 22 of 30
CXT, Inc. (Precast Div.) Kodiak KD-106 (NY) Date:06/1412019
—e—Ereeo t0.4H —®—NbMow 9
�..�.................... ...................«.....„.,................,,...,....... ...........
.,.�....,,.....�...
y �V" ....«..............yyry ppw
�µ......,..,..,,,,,,,,,,,,,,,,i14 ...... ............, ,Tw......",m...�...» Wndow2 .....,V*�hrvw13
—ie—NhMaw9 —.—Medi
p.........N...........
."........,...... ............... .. �,...�.,,.. .
REINFORCENIENT AT OPENINGS
.
P¢meY NWuudGPumwawu tl.%'kppM' dtlh�MG w LO�w.0 p.NA klu
�'�q...
...�,
. 1C.M.A._r
Opaevdg kIN#tmuurtau Lxmion Vsrtienlloceinn P.Ew'.e�g?b of u4waiag HI.u�.igla dww. '.(•y"i4xri30aaer�1'� Y'W YUW favm'r<d waruted A[¢
upvmng (L0."i) purl Wu3 f�iaeiadtod (wa°L^TYId '.
.. .�....." ....�... ., ......i" kfi'_,_... ,.....aii"'"` aas'rp'.
.,..�ifi' mj g, o� v9 ars, n
.........5.,�?.�1.�.,,.....:,�;,.:9.�:...._��......,.._..?R_.......... _.....+�'.4�...�
Fo, _
._....,....._ _..._........................._....�_......._._.. .. y............. a......_,..,..................._
............ Cyrneog _.....
mg
.,....,... "��' ........ ...»... .3 ....,.u.o"al^�".k..___ .k. L ...and .. .5.°.'....
AN ._
CONNECTIONS
au ( M a p.
T+r7r�R 9"d'"ham S fi.6"v Yw�IF
�77
g91stB of aecll loatl hn "nll Wall h L DIY Ftlro
zi
W+Spi�,. ......... ...........
.....,.._._... ................" ...... ....�. +*r_....."._.W.. .. rce sn.ar cavecM(b)�r sa-,a
DA
: L
�.. . Wim:m :- .a ::-.....:_ ...w: : W w ... CK
RIGIDITY
SiARIGE7 ,dl1:V1._.". ^ M 'f. ._A L ate.
a
4 ':.
vr,¢d¢wa r
.�.. .....3...'.�'" .,...Y.. ._.'..,...... „.:�..:.....G"f+�_'.w'
Pag6 20 of 30
CXT, Inc. (Precast Div.) Kodiak KD-106 (NY) Date:06114/2015
........... MUM=
......................................
.......................
...........
REINFORCEMENT AT OPENINGS
...........
L'2YI2
...........
CONNECTIONS
..................
Z=
Q
Rk'
Fill
AA- 29,
9F1
.. 8�Con—Wr
R—GK-
- - i4 ,
............-1. - 1M...- I., C111"
IUGIDffY
E. 0 9D45OD328
CXT Inc. (Precast Div.) Kodiak KD-106 (NY) Page 18 of 30
� Date:06/1412019
REINFORCEMENT AT OPENINGS
+smalid a
u.
�„w.. uon lengria oC oN>anwy kC h'ght pPxrvc. (-)Wepej i of Pw b¢al G lorded wu¢n+al hfu
Wn& OP 9( [,enol bed pusanr'a",dl..d (vruR.`2y12
w�w
plr m
n.rega P) du itvru�aa kndw �",. �,...,_.y
.._.._.. ..... M&m ...Pubtll L+�—
CONNECTIONS
. .„... ,...w. AM—
DWmh t d Wnp,�...M....�.� .,..�
.„1'.p�•adlwtl,
--
st Cmc+uwr+w:M¢ra¢u d9d Wdr W"Yxau�"kwmpM�dgy� w. Required 96Pear CaP$�A'(�)F�'
u gn A�Wyrd�aCp A9aaigry Glm+aadFk Reer�a
R-
=:=m
Cap-Hy
... �_w Wm) OK
RIGIDITY
30
CXT Inc. (Precast Div.) Kodiak KD-106 (NY) Page 16 of 19
� Date:06/1412019`
REINFORCEMENT AT OPENINGS
3 ?.m9k arxlep gB w fiOwbp $XewP.a
_ _ I"um mkxaW I unw arvt ___o _ ___ _ _O}renumg &i rari¢rvnroa9 Gmaxawr 'M e Glc p{{p A ecmpdr u0.'oM+�+m& pCpq ld gcdyt n Ittppl f.)zll et" h'w msrnl Cnou+e¢«1 cw mwd Mn
6�..,...,,...,.,..,.�,,,,. ......... .......�..,.,,.,..,�....,.6...�.,.,,.,..,,..,..,.,...,....,.L .� ...CJL.trPwm6(1µ1i57....�,....,...t:nrx^IXIrvmI,.,....W��Iwaaizad ixd l(an•l.'2Y12.
..............� _.... ...,.,.,....ry,...�,..,,..,,«&_ .................._....,....tYi!ai ul__...... �.
..............._.....6i iurN3,..,..w.,.,�.,�.»,.....,.,..,�.,.,, �'dr._ ��.W.......A»vm.��.......,..,_�...,.... p. ..�.�.�...�.q,_.......,........._
CONNECTIONS
Y4hu4YYy xraliWilY{i "" "' AN
crm�nury
Fl+U
_,w eb,� oim ax wenio --..
arMitlwirs areach Sao- �u
�ww. ..
. ."'""""""'•••"�""nes ua,^waew+amD+ra az 6ace.....
YSM A Shift vur.�r aaamwZN ._.-- ____.._...
Rau�uirocl Ghemr Capsatp Qbr por
U�em�q" C PmsM Rase 4',Mpw3gWi. Redme Reartromm
.dA Lm.I I:d 9}r � ,..w Bmse Ounnaclur c�'aGnyw tM
........,.».,.... _.�. ..,.�...,„, x' t,,.,.,A,.,....,. .w.............. ... ....�'IY ,.,.,...�X,..... (19704) OK
RIGEDITY
0810035us
30
CXT, Inc. Precast Div. Kodiak KD-106 Page 14 Of
�� Date:06/14/2011
�
—»-.E,,e,VM
4
REINFORCEMENT AT OPENINGS
f,ar�'k . P raw6rW 6 I,
gmdn a rI az far .. �gdp vw� 4
?w�
8 l.M:atiou L kelglhof og�evie®W W •,• rsl tal ryG{�, hfn
dl;.. M....W.. (kvmvsd load V( L'2Y12
..............
6h f^7 pJr e
Pa»�4+8 w�a�C
6'7»rru»waw
.......,.�,..�_�_�� ............_........w�.._.._�:_.�.... ........_ Ramo �d Parr, � `�........... ���,9k^?P. ._.�
CONNECTIONS
.-------—....................... ..... ��'"....T�}."�2»�..__...,. ,..........,..,.,,,.W«.
1 _...... ... _ k .�...,,.,_
IZZL— z -RPAp
c "
ir
ops nuow,an�� a�O'wnafti+*w wd
st
6P r c6a t9 .w WVwM kiWr49k 4.w Y8aN4p Reyufred SfiTear Capaa4y(b}Per
D aly r Capedty I Rdmn tlSaM1f C R d9s ra Baae Carwre Mr R—rv&
..............Ai�.�.'�..,.,...�. ...,.,.��:.,....YY........�,NNW..w. .�.,...........I�9...�.......... t.' �_.....,.LL.,...,....,..,,...�'.�....,..... ., .� .........,...,.,.,......... (384791 OK
p^ ^y RIcmIT-Y
1.,., ..,. n.� }.. � i.��..... '.'"...,.w.„1.�........!'' ...............H 4.4 5 1344 168
Page 12 of 30
CXT, Inc. (Precast Div.) Kodiak KD-106 (NY) Date:06/14/2015
—E.*.V 1 —D-1
REINFORCEMENT AT OPENINGS
()µ% R kI:rw d f umw w"�,awmD D +ewxm L I Ral.t pw & N G+gbt Wve (-)Wcghr of Pw mval Eeciarard m1e1 Rta
v�+me. cw�s Ices) peuel land ���a� I �.zriz
CONNECTIONS
... ElA5N+n. 20
V.
.WJ,I. ,... s
KE_YMAXAA , lim� .I,:.....
. 1r.:'
uuanuy GoT" SII2amuft.
quamity alie�o� olra sx ww ..5� � �
of M�tlwrs of rh Lnatl fiem dllw¢ Wefl L Det
b!ce d�mr nvmuerre RAFaa GWaw.mS%�Y Required ehaar GaPeafY(6y Pm'
gaxyn d"dMdrt,'Nkf R egnte CMnmlyuv. 1@m44AddcttWvp RuOK-
earwd
(�eztp OK
RIGIDITY
41.... .,.Cetit—
N. YG. &M. iC„ .I) yyryry� ME D—1
Dwr 1a. „I,.._,,...
r
Page 10 of 30
CXT, Inc. (Precast Div.) Kodiak KD-106 (N) ) Date:06/14/2019
.......... ,
... ...____v_._....
C
REINFORCEMENT AT OPENINGS
ma$,rj
Awdq ane»b AR 'y„ _
Dpaomg $i Ww AN$1„'wtawwMA W�RO,Neetl$dKUMmXN [IanBrh UI operting H h @}t Cq ()Wn�l C P W Cacal ,ale! h W
apo g Dlmao•A(LDS) penal land Gcmmsd load
DF vy �y Aa road 6 qly modY C.Msk
CONNECTIONS
............ ...... ................
n_.. 'AtiFI htn AP,i Ct'�2M,k� ...3I&GLfR IVP `..
.......
......._4 �,. .b _w..w.w„ ��„r"+a.,mmw
lh
Quantity l:apeoty Wunmrm9 LMad oC" Adiaovnµ D1.1M
PAowable L
�El
V'aI�WPW�MI�',.�. •... . � r .,,,.,. +t ,...,. �t,+I�7n �........�, 9 d,8
snoarewro+ (erwwetd"""" , "." " ' T
nk^IAvao&,q!$waaroy
Reery lad Shear Capamy(Ib}per
Daalgn�� Gapmruly Ra r GwwwyF« Ptlww Re�rva
-9921) OK
"k. __, D>aa conn wr ce�ary
RIGIDITY W
1958979876
D.,t
........... _w .. . .. .... .W_ww _..
Page 8 of 30
CXT, Inc. (Precast Div.) Kodiak KD-106 (NY) Date:06/14/2010
................ .................
.............
—EM.Wd —D-1
.......... —----- .........
............
REINFORCEMRT AT OPENINGS
-Xi
IkI ,r14 k. .SYN,.!_
army. ----
!fl 2YII
E
7 --M
-Sl —.9.010
CONNECTIONS
YA
,FV
_bw
—IZZL L
Qu.mdty ft. Adj.idn Dia —bW
wd
I J,
..... ...... ....
C.P.dty
11
(am OK
RIGIDITY
ISAQ232995
2"1
D.rl 211,...,_..... .......
D-1
30
CXT Inc. (Precast Div.) Kodiak KD-106 (NY) Page 6 of
� Date:06/14/2019A
o
x e
.0
JIB n
_.
o it
33
_w
r t� u a
1 ff7l
4, .„
01
a '
A
CXT Inc. (Precast Div.) Kodiak KD-106 (NY) Page 4 of 30
� Date:06/14/2019
Center of Mass & Rigidity
Kodiak KD-106
wad va
_"SoftTn._,.w ftt�n......,. A.,
L m-gyn..
? .
wan ro'wet-ae�warr
GM'b tft.�/% p,kNdV1Nh Bgg MSS&..... dFR."M�W .4 t4
,. 7. �
. _22 ..
_ mrtFm Mm—rd an
W-L
...,.,„M ....� �. :. .�.. .,,.� . . . ', fes...•.
�$ Rcaonkttl¢,rity, VrSt Fvsgt wgt
e d.aw t twl ;-&,j= L �wL. _d�9 �
5th w w 4.. L at �: . x
On's
.......................Wall Gkertuming(:trecks U61ng WelBht of Adprent WdBa............
�
,R.Nd a erUnni d TPaW^SPME LOwer Rip�XME TeOW pow.40A.MQt I; 4A'IpMfdYYpv adMAPk
M Ra stet Ovartdming rnerd�k"VY�b s'4MMCa APMtYwFR&CMaA&flr'ttkMr uWlafp'�vMdnVNmXWIgW&A
,,,, Fram Dospn Marrmnk Morrell ManaMMa exw�+l'vosMYa
.......... .... � .��'�.*.4M.�...,..,, a'nvMeb'. fi cl'.'Mw'Ac.
....' ®.. .,...,.rovgs' .......................... o- ...... .....
.. n�c��.m. t ...
qMNti& www. _ t0 1 C
.....,......)SA M",�,....,�....�.... . .... .,_„.ECS.
Oveft`rg—is�e ro mrlvde rdy tne—iphtatthe H.th—ightofthe mof mpported by the wall,end conne*n to ad nlwelis.Rodmight
attppomedbyoftrmlHhaanotbea Ademd.ConrmcUontoadjec mmhslstekenaeffmmnmetonmpecitj.rwtwe*adthalpoNonoftlioed}acent
mU wmlght that mn bo rsamnably atblbut,d to the wnnocgon,
........................... .......m.... ..,..........®.. «.....,,,..,.....,,,...........�.m»......,,,.,....,...µ.......,,,.ms.....
Wdl Gvanuming CtiaGm Using Bem Andmm Grdy
..........._.............. Must lnv...... grfm Yoweni vraAr:g lr ,d9lzatR� ................................. ,....
asti aes O LY' nnrc,��pn to�,�annn.
Design .�..., .ward owor hsu�"tit".. upper tort ""'L"o"rctiired Roqui dTenelon
Mo-nt Fvrchar Rosisfenre Mchor Re�slanea Loading Capac&y Por
Morrent Unity D.am Antlmr Qb)
Mel
........'k .......... ....
Y^��.__, saw
MAO O
bad lin#tor QtftlleM Mttlaa I�gkAkp4�1�'M "'k
sh— Tarwion 6d"'akupwea�(WP,4) Unity Cheek of
Ro pmd Aual.W 8rawrwk6—A."m Baaw 'a
CID,
..
_...kms....,.
ut—
...... ....., k,. 7�hw�...
...�.&&,P.ISI.
."
_�.........? ._.... ..._± .PC_..... M,rk.
,........ ... ,. ....... r"... x ......
CXT Inc. (Precast Div.) Kodiak KD-106 (NY) Page 2 of 30
Date:06/14/2019
ASCE 7-10 SNOW LOAD CALCULATION _
Category 1T See ASCE Table 1.5-1'Risk Catego of Buildings and Other Structures.
Excrsure - C See§26.7.3:E sure Categories,General.
P 250m See ASCE Figure 7-l:Ground Snow Load
W.buildin 10.5 ft Length of the building
L.building 23.67 ft -Width of the buildine ..
H.buildin 9.74 ft Heipht of the bu ld n to the rid emm Enter 0 if unknown.
Roof Rise(pe fcot
S 4 � Roof
Roof
_ .. .. .....w . ASCE Table 7-3-Thermal Condition: C
All structures except as indicated below: 1.0
Sctructures_We_pt3ust ve ---g and others with cold,ventilatedroo s m w is e erm resistance(k-value)
�betweert the veuhlated ace and the heatcd space exceeds 25'h..deg*sq fUBTU 1,l
Unheated and open air structures_ 1.2
Structures inlPA160pally kept below freezing
_ 1.3
f onUnuous y gr ouses wt a roo vmg a erm resistance e - e.) ess Mian l fit°t (deg*sq
ftJBTU), 0.85
C 1.2 (Choose from table above)
Is 1 ASCE Table 1.5-2
Surface Unobstructed ASCE 7 4
Roof tvDe Gable
Hor.Eave to Ridge Distance
windward 5.25 ft
Roof Exposure PartiW exposed ASCE Table 7-2
Cp 1 ASCE Table 7-2
Cs 1 Slope Factor from Figure 7-2
Low SL ed?: Yes ASCE§74
Pr 210.00 sf Flat Roof Snow Load
P 210.00 Sf Sloped Roof Snow Load
Use unbalanced? Yes ASCE7.6.1
-
P M 0.00 Sf ASCE, 7.6.1
P � 250.00 3rsf ASCE§7.6.l
PLr21� 250.00 psf_ .w. ASCE J7
Distance from Ridge to,Edge
of P ,., loadin 5.3 ft ASCE Fi urge 7-5
30.00 f Snow density jEq,7.7-1 of ASCE 7
S 4 Run M rise of 1 ASCE 7.1
hd 10.19 ft ic" tt of driftinfl,snow on leeward side
h 7.00
ft____j He w p.of balanced snow
30 Snow Load on Gable Structure
t
m
20 . ...... r,...,....._,wwa.ww..
C t --- —STRUCTURE
t
IS .....__ _. ..,._._...... Balanced Snow
10
� � ----Unblanced Snow
_....ww. _ _.w. _...._ ..._..._
5 ...................._......................w..........._...........W,m,.- .....___..w.....-....-......._.._....._.....,............-..._........... ............-. ...__.
p _.--
0 5 10 15 20 25
Structure Cross Section
NEW YORK STATE DEPARTD_ .rT OF ENVIRONMENTAL CONSERVATI
Facility DEC ID 1-4738-01144
PEt.MIT
Under the Environmental Conservation Law � mmm mmmmmmmmw _
N..___ .._........_w_w_ ._.. � Permittee and Facility Information
Permit Issued To: Facility:
MATTITUCK PARK DISTRICT VETERANS MEMORIAL PARK
P O BOX 1413 11280 PECONIC BAY BLVDISCTM 1000-126-
6-17 & 18 and 1000-126-5-20.1
MATTITUCK,NY 11952-0997 MATTITUCK,NY 11952
(631) 872-5195
Facility Location: in SOUTHOLD in SUFFOLK COUNTY
Facility Principal Reference Point: NYTM-E: 707.36 NYTM-N: 4538.79
Latitude: 40°58`26.2" Longitude: 72°32'07.8"
Authorized Activity: Demolish and remove two existing buildings; construct a new comfort
station to be connected to an existing sanitary system. All work shall be done according to
the plans prepared by L.K. McLean Associates (8 pages) stamped NYSDEC approved on
3/2/2018 (DEP-ARNO).
Permit Authorizations
Tidal Wetlands -Under Article 25
Permit ID 1-4738=01144/00020
New Permit Effective Date: 3/2/2018 Expiration Date: 3/1/2023
ww..._....... ._�........_......w_ww... ._,._......____.M_. NYSDEC Approval
_ - ......_, ww_...... ........_...._._..._._...._..w__._.w
By acceptance of this permit,the permittee agrees that the permit is contingent upon strict
compliance with the ECL, all applicable regulations, and all conditions included as part of this
permit.
Permit Administrator:MARK CARRARA, Deputy Regional Permit Administrator
Address: NYSDEC Region 1 Headquarters
SUNY @ Stony BrookJ50 Circle Rd
Stony Brook,NY 11790 -3409
Authorized Signature: ......._......._........................ w.....__ Date 3 / 2 / --aOl
Page 1 of 5
NEW YORK STATE DEPARTI VT OF ENVIRONMENTAL CONSERVAT,
Facility DEC 1D 1-4738-01144
__.........._ ._._. .._..__._._.. .,,,,w,�.._W.._..........
.__.M_....
. ..... ,a......ww...�.... � '_.. .._ _._._�........ .
Permit Components
NATURAL RESOURCE PERMIT CONDITIONS
GENERAL CONDITIONS,APPLY TO ALL AUTHORIZED PERMITS
NOTIFICATION OF OTHER PERMITTEE OBLIGATIONS
NATURAL RESOURCE PERMIT CONDITIONS - Apply to the Following
Permits: TIDAL WETLANDS
1. Conformance With Plans All activities authorized by this permit must be in strict conformance
with the approved plans submitted by the applicant or applicant's agent as part of the permit application.
Such approved plans were prepared by L.K. McLean Associates and stamped NYSDEC approved on
3/2/2018.
2. Notice of Commencement At least 48 hours prior to commencement of the project,the permittee
and contractor shall sign and return the top portion of the enclosed notification form certifying that they
are fully aware of and understand all terms and conditions of this permit. Within 30 days of completion
of project,the bottom portion of the form must also be signed and returned, along with photographs of
the completed work.
3. Post Permit Sign The permit sign enclosed with this permit shall be posted in a conspicuous
location on the worksite and adequately protected from the weather.
4. Storage of Equipmcnt,Materials The storage of construction equipment and materials shall be
confined within the project work area and/or upland areas greater than 75 linear feet from the tidal
wetland boundary.
5. Area of Disturbance for Structures Disturbance to the natural vegetation or topography greater
than 25 feet seaward of the approved structure is prohibited.
6. No Beach Excavation For Fill No excavation of the beach is authorized for the purpose of
obtaining fill or stone materials.
7. No Changes to Septic System This permit does not authorize any alteration, expansion or
replacement of existing septic systems.
8. Concrete Leachate During construction, no wet or fresh concrete or leachate shall be allowed to
escape into any wetlands or waters of New York State, nor shall washings from ready-mixed concrete
trucks, mixers, or other devices be allowed to enter any wetland or waters. Only watertight or
waterproof forms shall be used. Wet concrete shall not be poured to displace water within the forms.
9.-No Construction Debris in Wetland or Adjacent Area Any debris or excess material from
construction of this project shall be completely removed from the adjacent area(upland) and removed to
an approved upland area for disposal. No debris is permitted in wetlands and/or protected buffer areas.
Page 2 of 5
NEW YORK STATE DEPARTA_ .T OF ENVIRONMENTAL CONSERVATI
Facility DEC 11) 1-4738-01144
to. State May Require Site Restoration If upon the expiration or revocation of this permit, the
project hereby authorized has trot been completed, the applicant shall,without expense to the State, and.
to such extent and in such time and manner as the Department of Environmental Conservation may
lawfully require,remove all or any portion of the uncompleted structure or fill andrestore the site to its
farmer condition. No claim shall be made against the State of New York on account of any such
removal or alteration.
11. Precautions Against Contamination of Waters All necessary precautions shall be taken to
preclude contamination of any wetland or waterway by suspended solids,sediments, fuels, solvents,
lubricants, epoxy coatings,paints, concrete, leachate or any other environmentally deleterious materials
associated with the project.
12. State May Order Removal or Alteration of Work If future operations by the State of New York
require an alteration in the position of the structure or work herein authorized, or if,in the opinion of the
Department of Environmental Conservation it shall cause unreasonable obstruction to the free navigation
of said waters or flood flows or endanger the health,safety or welfare of the people of the State,or cause
loss or destruction of the natural resources of the State, the owner may be ordered by the Department to
remove or alter the structural work, obstructions, or hazards caused thereby without expense to the State,
and if, upon the expiration or revocation of this permit,the structure, fill, excavation,or other
modification of the watercourse hereby authorized shall not be completed, the owners, shall,without
expense to the State, and to such extent and in such time and manner as the Department of
Environmental Conservation may require,remove all or any portion of the uncompleted structure or fill
and restore to its former condition the navigable and flood capacity of the watercourse. No claim shall
be made against the State of New York on account of any such removal or alteration.
13. State Not Liable for Damage The State of New York shall in no case be liable for any damage or
injury to the structure or work herein authorized which may be caused by or result from future;operations
undertaken by the State;for the conservation or improvement of navigation, or for other purposes, and no
claim or right to compensation shall accrue from any such damage.
_.__..........._m__._�._..._.GENE_..w_.__...........� CONDITIONS - APP RAL M......�.........d Permits:._..... ........_.....�.�
..._ 1Yto ALL Authorize...... .Permits: ..._,.w._._. _
1. Facility Inspection by The Department The permitted site or facility, including relevant records, is
subject to inspection at reasonable hours and intervals by an authorized representative of the Department
of Environmental Conservation(the Department)to determine whether the permittee is complying with
this permit and the ECL. Such representative may order the work suspended pursuant to ECL 71- 03,01
and SAPA 40](3).
The permittee shall provide a person to accompany the Department's representative during an inspection
to the permit area when requested by the Department.
A copy of this permit, including all referenced maps, drawings and special conditions, must be available
for inspection by the Department at:all times at the project site or facility. Failure to produce a copy of
the permit upon request by a Department representative is a violation of this permit.
Page 3 of 5
NEW YORK STATE DEPART1, _1T OF ENVIRONMENTAL CONSERVAT,
Facility DEC ID 1-4738-01144
2. Relationship of this Permit to Other Department Orders and Determinations Unless expressly
provided for by the Department, issuance of this permit does not modify, supersede or rescind any order
or determination previously issued by the Department or any of the terms, conditions or requirements
contained in such order or determination.
3. Applications For Permit Renewals,Modifications or Transfers The permittee must submit a
separate written application to the Department for permit renewal, modification or transfer of this
permit. Such application must include any forms or suppleiriental information the Department requires.
Any renewal, modification or transfer granted by the Department must be in writing, Submission of
applications for permit renewal,modification or transfer are to be submitted to:.
Regional Permit Administrator
NYSDEC Region 1 Headquarters
SUNY @ Stony BrookJ50 Circle Rd
Stony Brook,NY11790 -3409
4. Submission of Renewal Application The permittee must submit a renewal application at least 30
days before permit expiration for the following permit authorizations: Tidal Wetlands.
5. Permit Modifications, Suspensions and Revocations by the Department The Department
reserves the right to exercise all available authority to modify, suspend or revoke this permit. The
grounds for modification, suspension or revocation include:
a. materially false or inaccurate statements in the permit application or supporting papers;
b. failure by the permittee to comply with any terms or conditions of the permit;
c. exceeding the scope of the project as described in the permit application;
d. newly discovered material information or a material change in environmental conditions, relevant
technology or applicable law or regulations since the issuance of the existing permit;
e. noncompliance with previously issued permit conditions, orders of the commissioner, any
provisions of the Environmental Conservation Law or regulations of the Department related to
the permitted activity.
6. Permit Transfer Permits are transferrable unless specifically prohibited by statute, regulation or
another permit condition. Applications for permit transfer should be submitted prior to actual transfer of
ownership.
NOTIFICATION OF OTHER PERMITTEE OBLIGATIONS
Item A: Permittee Accepts Legal Responsibility and Agrees to Indemnification
The permittee, excepting state or federal agencies, expressly agrees to indemnify and hold harmless the
Department of Environmental Conservation of the State of New York, its representatives, employees,
and agents ("DEC")for all claims, suits, actions, and damages,to the extent attributable to the
permittee's acts or omissions in connection with the permittee's undertaking of activities in connection
Page 4 of 5
NEW YORK STATE DEPARTM r OF ENVIRONMENTAL CONSERVATR
Facility DEC ID 1-4738-01144
with,or operation and maintenance of,the facility or fficilities authorized by the permit whether in
compliance or not in compliance with the terms and conditions of the permit. This indemnification does
not extend to any claims, suits, actions, or damages to the extent attributable to DEC's own negligent or
intentional acts or omissions, or to any claims, suits, or actions naming the DEC and arising under
Article 78 of the New York Civil Practice Laws and Rules or any citizen suit or civil rights provision
under federal or state laws.
Item B: Permittee's Contractors to Comply with Permit
`flip permittee is responsible for informing its independent contractors, employees, agents and assigns of
their responsibility to comply with this permit,including all special conditions while acting as the
permittee's agent with respect to the permitted activities, and such persons shall be subject to the same
sanctions for violations of the Environmental Conservation Law as those prescribed for the permittee.
Item C: Permittee Responsible for Obtaining Other Required Permits
The permittee is responsible for obtaining any other permits, approvals, lands, easements and rights-of-
way that,may be required to carry out the activities that,are authorized by this permit.
Item D: No Right to Trespass or Interfere with Riparian Rights
This permit does not convey to the permittee any right to trespass upon the lands or interfere with the
riparian rights of others in order to perform the permitted work nor does it authorize the impairment of
any rights,title,or interest,in real or personal property held or.vested in a person not a party to the
permit.
Page 5 of 5
BOARD OF SOUTHOLD TOWN TRUSTEES
SOUTHOLD, NEW YORK
PERMIT NO. 9167 DATE: FEBRUARY 14 201.8
ISSUED TO: MATTITUCK PARK DISTRICT
PROPERTY ADDRESS: VETERANS MEMORIAL PARK
11020 & 11280 GREAT ''ECO IC BAY BLVD.2 MA'I'"CT UCI
SCTM# 1000-126-6-17&1.8
AUTHORI ATION'
., _m xr.. , �tf'i:. .�i. .is .. .i •Y..
Pursuant to the provisions of Chapter 275of the Towiag'Code of tlae''j oivf�i aaf°Sheatlical�d and in
accordance with the Resolution of the Board of Trustees adopted at the meeting held on 1" hruknLIA,.2018,and
in consid riation of application fee in'the siaria of"2, ,tl fly`paid by M�attitu Par 2ik""and safbj ct to the
Terms and Condition as stat din the'Resol itfon, the Sia ahold T60n`Il6rd of Trustees authdrizes'afad permits
the following:
Wetland Permit to demolish two buildings(a= las ,.ft.,comfortstation,and a 148s ,.ft;shed);and:
construct a new 167sq.ft.comfort station;"connecting new comfort station to upgratdecl saanitary.,system;
and a re-vegetation plan using.native beach grass species in the vicinity of the 61ew comfort station and
disturbed areas;and as depicted on the site plan prepared,by L.K. McLean Associates,P,C,received on
i
January 9,2018,and stamped approved on February 14,2018.
IN WITNESS WHEREOF,the said Board of Trustees hereby causes its Corporate Seal to be affixed,
and these presents to be subscribed by a majority of the said Board as of this.
._.
a
C4 ...... _..
r
f
ry
I
1 '
a °i
Sol/"" Tawn Hall Annex
Michael J.Domino,President
John M. Bredemeyer III,Vice-Presiden54375 Route 25
P.O.Box 1179
Glenn Goldsmith Southold,New York 11971
A.Nicholas Krupski Telephone (631) 765-1892
Greg Williams !/ Fax(631) 765-6641
BOARD OF TOWN TRUSTEES
TOWN OF SOUTHOLD
February 14, 2018
Christopher F. Dwyer, Associate
L.K. McLean Associates, P.C.
437 S. Country Road
Brookhaven, NY 11719
RE: MATTITUCK PARK DISTRICT
VETERANS MEMORIAL PARK
11020 & 11280 GREAT PECONIC BAY BOULEVARD, MATTITUCK
SCTM# 1000-126-6-17 & 18
Dear Mr. Dwyer:
The Board of Town Trustees took the following action during its regular meeting held on
Wednesday, February 14, 2018, regarding the above matter:
WHEREAS, L.K. McLean Associates, P.C., on behalf of MATTITUCK PARK DISTRICT
applied to the Southold Town Trustees for a permit under the provisions of Chapter 275
of the Southold Town Code, the Wetland Ordinance of the Town of Southold,
application dated January 9, 2018, and,
WHEREAS, said application was referred to the Southold Town Conservation Advisory
Council and to the Local Waterfront Revitalization Program Coordinator for their findings
and recommendations, and,
WHEREAS, the LWRP Coordinator issued a recommendation that the application be
found Consistent with the Local Waterfront Revitalization Program policy standards,
and,
WHEREAS, a Public Hearing was held by the Town Trustees with respect to said
application on February 14, 2018, at which time all interested persons were given an
opportunity to be heard, and,
2
WHEREAS, the Board members have personally viewed and are familiar with the
premises in question and the surrounding area, and,
WHEREAS, the Board has considered all the testimony and documentation submitted
concerning this application, and,
WHEREAS, the structure complies with the standards set forth in Chapter 275 of the
Southold Town Code,
WHEREAS, the Board has determined that the project as proposed will not affect the
health, safety and general welfare of the people of the town,
NOW THEREFORE BE IT,
RESOLVED, that the Board of Trustees have found the application to be Consistent
with the Local Waterfront Revitalization Program, and,
RESOLVED, that the Board of Trustees approve the application of MATTITUCK PARK
DISTRICT to demolish two buildings (a 575sq.ft. comfort station and a 148sq.ft. shed),
and construct a new 167sq.ft. comfort station; connecting new comfort station to
upgraded sanitary system; and a re-vegetation plan using native beach grass species in
the vicinity of the new comfort station and disturbed areas; and as depicted on the site
plan prepared by L.K. McLean Associates, P.C, received on January 9, 2018, and
stamped approved on February 14, 2018.
Permit to construct and complete project will expire two years from the date the permit
is signed. Fees must be paid, if applicable, and permit issued within six months of the
date of this notification.
Inspections are required at a fee of$50.00 per inspection. (See attached schedule.)
Fees: $50.00
Very truly yours,
0
Michael J. Domino,
President, Board of Trustees
MJD/dd
Town Hall Annex"
Michael J.Domino,President +r�► �1�/�
64375 Route 25
John M.Bredemeyer III,Vice-President AL JiroP.O.Box 1179
Glenn Goldsmith Southold,New York 11971
A.Nicholas Krupski Telephone(631) 765-1892
Greg Williams Fax(631)765-6641
COUNII
BOARD OF TOWN TRUSTEES
TOWN OF SOUTHOLD
YOU ARE REQUIRED TO CONTACT THE OFFICE OF THE BOARD OF TRUSTEES
72 HOURS PRIOR TO COMMENCEMENT OF THE WORK, TO MAKE AN
APPOINTMENT FOR A PRE-CONSTRUCTION INSPECTION. FAILURE TO DO SO
SHALL BE CONSIDERED A VIOLATION AND POSSIBLE REVOCATION OF THE
PERMIT.
INSPECTION SCHEDULE
Pre-construction, hay bale line/silt boom/silt curtain
1St day of construction
% constructed
zProject complete, compliance inspection
Michael J.Domino,President S0 Town Hall Annex
54375 Route
John M.Bredemeyer III,Vice-President '
P.O.Box 11799
Glenn Goldsmith Southold,New York 11971
A.Nicholas Krupski Telephone(631) 765-1892
Greg Williams + ` Fax(631)765-6641
BOARD OF TOWN TRUSTEES
TOWN OF SOUTHOLD
S m Water Runoff
With recent heavy rainfalls,we are reminded once again of the problems Southold Town has
with storm water runoff. With over 1.00 road ends terminating at creeks,bays,inlets,or long
Island Sound,as well as all of the lawns and homes lining our miles of shoreline, 100's of
thousands of gallons of storm water runoff enters our Wetlands'every year.
Carrying sediment that prevents sunlight from reaching aquatic plants,nutrients from animal
waste and lawn fertilizers that promote algae blooms detrimental to shellhsbi and bacteria and
other biologicals that in high doses can be harmful to swimmers, storm water runoff is one of the
Trustees main public safety conceins. So important, in fact,that Southold has a Storm Water
Management Code.
Southold Town's Chapter 236 provides an outline for how people need to deal with storm water
runoff from their properties. For example,new construction or renovation is re ,uired to contain
any potential runoff to the wetlands from the construction by installing hay bales and silt fencing.
This acts as a barrier and keeps our wetlands clean. Another example in Chapter 236 is that
every building rnut;t have provisions to collect and disperse, ON-SITE,at least a 2 inch rainfall.
"l lis is usually handled by installing gutters, leaders and drywells to the home. The Trustees also
have a standing policy of requiring pervious non-turf buffers along bulkheads and at tops of
bluffs that help keels run off from entering the wetlands and prevents erosion to bluffs. These are
important measures to keep our wetlands safe and clean.!
Before deciding to renovate or build, the Town Trustees urge you to check our website and the
other department's websites to make sure what you are planning to do meet the Town's Code.
These codes have been developed for the good of all citizens. And the wildlife all around us too!