Loading...
HomeMy WebLinkAbout48229-Z OSUF��t'flpG Town of Southold 5/15/2023 P.O.Box 1179 53095 Main Rd Woy�j01 dao fgSouthold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44097 Date: 5/15/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 230 Old Shipyard Ln., Southold SCTM#: 473889 Sec/Block/Lot: 64.-2-50 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/15/2022 pursuant to which Building Permit No. 48229 dated 8/29/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwellingas applied for. The certificate is issued to Frasca,Lauren&Kleiman,Michael of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL - ELECTRICAL CERTIFICATE NO. 48229 2/14/2023 PLUMBERS CERTIFICATION DATED Auth ize Signature TOWN OF SOUTHOLD �o�guFFQI,���G� BUILDING DEPARTMENT o - TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48229 Date: 8/29/2022 Permission is hereby granted to: Frasca, Lauren 54 Young Ave Pelham, NY 10803 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 230 Old Shipyard Ln., Southold SCTM #473889 Sec/Block/Lot# 64.-2-50 Pursuant to application dated 7/15/2022 and approved by the Building Inspector. To expire on 2/28/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector pF SO(/T�QI o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin(D-town.southold.nV.us Southold,NY 11971-0959 Q cou BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Lauren Frasca Address: 230 Old Shipyard Ln city,Southold st: NY zip: 11971 Building Permit* 4$229 Section: 64 Block: 2 Lot: 50 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Empower Solar License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Solar �( Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/C Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 7.225kW Roof Mounted PV Solar Energy System w/ (17) SPR425W Modules, Combiner Panel AC Disconnect Notes: Solar Inspector Signature: Date: February 14, 2023 S. Devlin-Cert Electrical Compliance Form ho��OF SOUTgOIo old --- # f TOWN OP SOUTHOLD BUILDING D 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE /2,2, _ INSPECTOR pF SO(/Tyo� # TOWN OF SOUTHOLD BUILDING DEPT. �`y�OUrm� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATI0WCAULKING [ ] FRAMING /STRAPPING [ FINAL cSa��f- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: o fGt,� 0�►5 � -0B — DATE S' 'oINSPECTOR FIELD INSPECTION REPORT DATE COMMENTS b FOUNDATION (IST) j►- H -------------------------------- FOUNDATION (2ND) M � z 0 p H ROUGH FRAMING& PLUMBING O r INSULATION PER N.Y. �H STATE ENERGY CODE a o - fL Cz. FINAL ADDITIOP4AL COMMENTS on /Xo -dl AwO Plo o o rn co S b N N o z x r� H x d b H SttffO t,�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y2"' Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o a4, y Telephone(631) 765-1802 Fax(631) 765-9502 bqs://www.soudioldtoM=.Rov Date Received APPLICATION FOR BUILDING PERMIT LJ For Office Use Only JUL 15 2022 PERMIT NO. Building Inspector: BUILDING DEPT: 70WN OF SOU7HOLD Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: 7/11/2022 OWNER(S)OF PROPERTY: Name: Michael Kleiman SCTM#1000- 064.00-02.00-050.000 Project Address:Y23.0.Old_Shi yard-Lane,,.-S.o.uthold,_NY 119Z1 Phone#�— 91.7-5478.$53_ Email: mkleiman41 @gmail.com Mailing Address: 230 Old.Shipyard Lane, Southold, NY 11971 CONTACT PERSON: Name: Sara McCaffrey (EmPower CES, LLC.) Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@empower-solar.com DESIGN PROFESSIONAL INFORMATION: Name: Gregory D. Sachs Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 — Phone#: (516)-544-4592 Email: permitting@empower-solar.com CONTRACTOR INFORMATION: Name: Em Power CES, LLC. Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@empower-solar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: XOthe Installation of roof mounted solar panels(18)SPR-425w ACPV modules 7.65kW total system Si2e$ 27,996.00 Will the lot be re-graded? ❑Yes IXNo Will excess fill be removed from premises? ❑Yes NNo 1 PROPERTY INFORMATION Existing use of property: Residential 1._F_amil_y Intended use of property: Residential 1 Family Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes K No IF YES, PROVIDE A COPY. IN Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The'applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Sara McCaffrey C4Authorized Agent ❑Owner Signature of Applicant: � Date: STATE OF NEW YORK) SS: COUNTY OF ) Sara McCaffrey being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this \� day ofSD \)U ,20 � QAIV in _Ryan M,I oxer NdTARY PUELIC,STATE OF NEW YORK Istradoh No.OIIVI06412506 PROPERTY OWNER A HOF�bI MIGINIsrauCounty (Where the applicant is '$9 December 28,2024 I, Michael Kleiman residing at 230 Old Shipyard Lane, Southold, NY 11971 do hereby authorize Sara McCaffrey to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date YA Print Owner's Name 2 EMPOCES-01 ABELLO ACORO� DATE(MM/DDIYYYY) CERTIFICATE OF LIABILITY INSURANCE 5/6/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0757776 NAMEACT HUB International Insurance Services Inc. PHONE No,Ext): 310 568-5900 FAX 600 Corporate Pointe ( ) (AIC,No):(310)568-9098 Suite 600 ADDRESS: Culver City,CA 90230 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Southwest Marine&General Insurance Company 12294 INSURED INSURERS:James River Insurance Company 12203 Empower CES LLC INSURER C: 4589 Austin Boulevard INSURER D: Island Park,NY 11558 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS L D D M DD A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE FX OCCUR X PK202200006109 5/4/2022 5/4/2023 DAMAGESTO (RENTED 500,000 PREMISES Ea occurrence) MED EXP(Any one erson 51000 PERSONAL dADV INJURY 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERALAGGREGATE $ 2'000,000 POLICY[XI zRof FILOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY EO.cccdeD SINGLE LIMIT $ ANY AUTO BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY Per accident $ $AHIRED OOSONLD PPEaRTY AMAGE ONLY ARRO B UMBRELLA LIABX OCCUR EACH OCCURRENCE $ 5,000,000 X EXCESS LIAB CLAIMS-MADE 001306870 5/4/2022 514/2023 AGGREGATE $ 5,000,000 DED I I RETENTION$ WORKERS COMPENSATION AND EMPLOYERS'LIABILITY Y/N PTAT TE ER OFFICER/MEMBER EXCLUDED?ECUTIVE NIA E.L.EACH ACCIDENT $ (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) The certificate holder is listed as additional insured per attached endorsement#GL0202 0218. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Town Route h ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD I NY S ' F PO Bax 66699,Albany,NY 12206 New York State Insurance Fund �nyslf eom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE A^^^"^ 522407627 0. '0 AMWINS BROKERAGE OF NEW YORK 200 ELWOOD DAVIS ROAD SUITE 200 ❑ LIVERPOOL NY 13088 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER EMPOWER CES LLC TOWN OF SOUTHOLD 4589 AUSTIN BLVD 54375 ROUTE 25 ISLAND PARK NY 11558 SOUTHOLD NY 11971 POLICY NUMBER I CERTIFICATE NUMBER POLICY PERIOD DATE Z 2546 6,' 563452 5/0112022 TO 05/01/2023 04/12/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2546 624-4, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COWCERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY AFFORDS COVERAGE TO THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. DAVID SCHIEREN GREG SACHS EMPOWER CES LLC THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND 4 DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 263370983 IIIIIlo00000000001ON3=33805 87411111 Form WC-MT-NOPRINT Vergm 3(OBI292019)[WC Policy-254662441 U-26.3 163 [DODOODWOOO103338%4][x001.000D7sMW"3[##4[L%9-79]Mfft T_II01-x0001] Y"ORK workers' CERTIFICATE OF INSURANCE COVERAGE STATE CoBoma ard NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured EMPOWER CES LLC DBA EMPOWER SOLAR 310-534-7994 4589 AUSTIN BOULEVARD ISLAND PARK,NY 11558 1 c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 522407627 2. Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"1a" Southold, NY 11971 DBL252634 3c.Policy effective period 05/10/2021 to 05/09/2023 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described abbovhf ee.. Date Signed 5/9/2022 By Wdl, (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 46,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 4B,4c or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) IIIII IP111°°1°20°°1°°°121°1111°°I�I�I Additional Instructions for Form 1313-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1 a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law. The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage(Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier. This Certificate is issued as a matter of information only and confers no rights upon the certificate holder.This Certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any . permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first, two thousand eighteen, the payment of family leave benefits for all employees has been secured as provided by this article. 1313-120.1 (12-21)Reverse I Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name GREGORY SACHS Business Name s ce rfifies that the EMPOWER CES LLC DBA veris duty licensed he Courty of suffolk License Number:H-50211 Rosalie Drago issued; 05/30/2012 Commissioner Expires: 5/1!2024 I Suffolk County Dept.of Labor,Licensing&Consumer Affairs l HOME IMPROVEMENT LICENSE Name GREGORY SACHS Business Name s certifies that the 7 I EMPOWER CES LLC DBA i firer is duly licensed i .he County of suffolk License Number:H-50211 Rosalie Drago Issued: 05/30/2012 SConrrissloner Expires: 5/1/2024 1 i Suffolk County Dept.of Labor,Licensing&Consumer Affairs tom' MASTER ELECTRICAL LICENSE Name TIMOTHY M GROTTY Business Name This certifies that the Empower CES LLC DBA nearer is duly licensed ,y the County of Suffolk License Number:ME-65990 Rosalie Drago Issued: 11/12/2021 - Commissioner Expires: 11/01/2023 rW E LLQ � V E �;.Agufl'01,��, JUL 1 5.2Q%PuILDiI G EPARTMENT- Electrical Inspector TOWN OF SOUTHOLD BUILDING'DEPT. #oma" =`t TOWN!OF$dWrVHFJII Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 a 4� ��,.. . ® :��` Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr a�southoldtownny.gov seand aAsoutholdtownny_,gov- AP'P:LICATI.ON FOR ELECTRICAL INSPECTION: ELECTRICIAN INFORMATION (All Information Required) Date; 7/11/2022 Company Name: EmP_ower.CES,-LLC. ° Name:- Timoth--Croft License No.: ME-65990 email: ermittin em ower-solar.com Address: 4589AustinBlvd.-,_Island_Park,-NY 11558 Phone No.: (516)-544-4592 4 JOB SITE INFORMATION (All Information Required) Name: Michael Kleiman Address:- 230 Old Shipyard-Lane, Southold NY 11971 Cross Street: Phone No.: (917)-547-8853 Bldg.Permit#: email: mkleiman41 @gmail.com Tax Map District:._ 1000 _Section: 064.0.0 Block:_02.00 Lot:_050.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) } Installation of roof mounted solarpanels ACPV modules 7.65kW total system-size Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph3 Ph Size: _ _A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected-Underground -Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information":: -PAYMENT-DUE WITH APPLICATION Request for Inspection FormAs Gregory Sachs, PE 4589 Austin Blvd, (516)-544-4115 Island Park, NY 11558 permitting@empower-solar.com August 22,2022 To Whom It May Concern: The purpose of this letter is to certify that the existing roof structure located at: 230 Old Shipyard Lane,Southold,NY 11971 can support the additional load of the solar energy system, in addition to wind,snow and gravity. Portions of roof structure covered and not covered with photovoltaic panels are in compliance with R324.4.1.1. Furthermore, it has been determined that the structure complies with the 2020 Residential Code of New York State including the ASCE 7. Please see Table 1 below for specific data relating to the calculations for each roof structure involved in the solar energy system installation. Table 1 Rafter Snow Wind y Roof Surface Max Span spacing Cross Section Load Speed Kneewall Collar Ties La ers of (ft) (in) (psf) (mph) Shingles South 1 9.92 16 Nominal`2x6 20 135 Yes No 1 Sincerely, Gregory Sachs, PE OF IAE W D r LU to uJ CD Og45' S �/A • V� Gregory Sachs, PE 4589 Austin Blvd, (516)-544-4115 Island Park, NY 11558 permitting@empower-solar.com July 8, 2022 To Whom It May Concern: The purpose of this letter is to certify that the existing roof structure located at: 230 Old Shipyard Lane,Southold, NY 11971 can support the additional load of the solar energy system, in addition to wind, snow and gravity. Portions of roof structure covered and not covered with photovoltaic panels are in compliance with R324.4.1.1. Furthermore, it has been determined that the structure complies with the 2020 Residential Code of New York State including the ASCE 7. Please see Table 1 below for specific data relating to the calculations for each roof structure involved in the solar.energy system installation. tri us4- be f oc&44 duos 14e. 1 14;e_14-Cl f Table 1 reo_Jr (y a ccefoLk_ Rafter Snow Wind Roof Surface Max Span spacing Cross Section Load Speed Kneewall Collar Ties Layers of (ft) (in) (psf) (mph) Shingles South-West 1. 14.75 16 Nominal 2x8 20 135 No No 1 Sincerely, of NlEty Gregory Sachs, PE �P�GOFtY D �0 APPRO11ED AS NOLU ED DATE: 0 O , -3 / ,o � FEE: . GY: SS`ONp NOTIFY...:BUILDINC DE-P,-'�RTMENT AT 7651802;_8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: COMPLY WITH ALL CODES OF I. FOUNDATION,- TWO REOUIRED NEW YORK STATE &TOWN CODES FOR POURED CONCRETE AS REQUIRED AND CONDITIONS OF 2. ROUGH FRANIING & PLUMBING 1 INSULATION t�1 I 4. FINAL CONSTPI MUST BE COMPLETE S I OARD ALL CONSTRUCri_7,( "!'HALL MEET THE _CQUFh9Ln MAIN]TRUSTEES REQUIREMENTS Or 7HE"ODES OF NEW �ivc nrn YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. r 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER OCCUPANCY OR I I SOLAR USS IS UNLAWFUL 4589 AUSTIN BLVD ISLAND PARK,NY 11558 WIT UT CERTIFIC/ o TEL:516-837-3459 FAX:516-706-1789 RESIDENTIAL www.empower-soIar.com OF OCCUPANCY HN IS THE SOLE H SOLAR PROJECT H PROPERTY OF EMPOIWER CES,LLC UNAUTHORIZD REPRODUCTION OR DISTRIBUTION OF THIS PROJECT TEAM. MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL OWNER: Michael Kleiman ELECTRICAL G G INSPECTION REQUIRED OF NEpp y P PHONE: (917)547-8853ENGINEER OF RECORD: F SOLAR INSTALLER: GREGORY SACHS,PEr t EMPOWER SOLAR 4589 AUSTIN BLVD 4589 AUSTIN BLVD ISLAND PARK,NY 11558 , ISLAND PARK,NY 11558 A JV 4 53� ��C9 PHONE:516-837-3459 PHONE:516-837-3459 E E ;Fy; O�cSSJONP O f .. D 'tray`t., D REV: DESCRIPTION: DATE: PROJECT LOCATION DATA: SHEET INDEX: PROJECT NAME: C ` Michael Kleiman 1ec ADDRESS:230 Old Shipyard Lane, ST-01 COVER SHEET \% ?~ Southold,NY 11971 S-01 EQUIPMENT LOCATIONS PROJECT LOCATION: S-02 STRUCTURAL` SE-01 ELECTRICAL c 230 Old Shipyard Lane, •230 Old Shipyard Ln�r Southold,NY 11971 Southold,W 11971 �• SCTM:1000-064.00-02.00-050.000 PROJECTM PROJ.PHASE: PERMIT .0, DATE: B 31s e\�1�� s B DESIGNED BY: ED CHECKED BY: GS SCALE: NTS MAP TITLE: COVERSHEET A A SHEET: ST-01 1 2 3 4 5 6 7 8 9 10 11 12 13 E V E � \VI E ffIJJJ LLLlll JUL 1 5'2022 BUILDING DEPT. TO\NN OF SOUTHOLD 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 o TEL:516-837-3459 FAX:516-706-1789 www.empowe r-sol ar.c 0 m THE INFORMATION DISCLOSED HEREIN IS THE SOLE H H PROPERTY OF EMPOWER CES,L.C.UNAUTHORIZED REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT DRIVEWAY PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL 4 G G EQUIPMENT LEGEND: 2 O OF NFA MODULES � RY GO UTILITY METER �3 INVERTERS 1 Epw 53' ��C7 4❑ SOLAR DISCONNECT v =SSIONP�" MAIN SERVICE PANEL O SETBACK LEGEND D ❑ D REV: DESCRIPTION: DATE: ® 36"CLEAR PATH PROJECT NAME: KLEIMAN RESIDENCE ® 18"RIDGE SETBACK SOUTH-WEST-1 ROOF: PROJECT LOCATION: C 18 SUNPOWER 425W-ACPV PANELS 3 C 230 OLD SHIPYARD LANE TOTAL POWER:7.65 kW ® ACCESS ROOF SOUTHHOLD,NY 11971 ORIENTATION:230°;PITCH: 18° z TYPE 1:FLUSH MOUNT rn SOLAR ACCESS:95% PROJECT#: PROJ.PHASE: PERMIT TSRF:86°/D DATE: 07/08/2022 B B DESIGNED BY: ED CHECKED BY: GS SCALE: NTS TITLE: EQUIPMENT LOCATIONS ROOF LAYOUT A NOT TO SCALE A SHEET: S-01 1 2 3 4 5 6 1 8 9 10 11 12 13 - 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER SOLAR 4589 AUSTIN BLVD SUNPOWER MODULES ISLAND PARK,NY 11558 C> ON INVISIMOUNT RACKING TEL:516-837-3459 SHINGLES FAX:516-706-1789 ww w.em p o w e r-sol ar.c o m THE INFORMATION DISCLOSED HEREIN IS THE SOLE H RAFTERS H PROPERTY OF EMPOWER CES,LLC.UNAUTHORIZED REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL G G OF NES ogy 1). F TYPICAL ROOF SECTION C7 L NOT TO SCALE C) 1 - s ,i _LL SUNPOWER PANEL SPECS X453\ E MODULE POWER(Wdc) QTY MODEL# LENGTH WIDTH DEPTH WEIGHT TABLE S-1.1:MAX.ATTACHMENT SPACING E SPR-425 118 SPR-A-SERIES-AC 72.2" 40.0" 1.57" 46.5 LB PORTRAIT: 5'-4" LANDSCAPE: 8'-0" =SSIONP SPR-E/X-SERIES-AC 61.4" 41.2" 1.81" 42.9 LB D D REV: DESCRIPTION: DATE: NOTES: PROJECT NAME: 1. TOTAL SYSTEM DC POWER:7.65 kW Michael Kleiman 2.RACKING SYSTEM INSTALLED IN ACCORDANCE WITH CODE-COMPLIANT INSTALLATION MANUAL 3.ATTACHMENTS TO BE SECURED TO ROOF ASSEMBLY USING 5 mm STAINLESS STEEL SCREWS PROJECT LOCATION: C AND/OR 5/16"STAINLESS STEEL LAG BOLTS SPACED,ACCORDING TO TABLE S-1.1 C 230 Old Shipyard Lane, 4. ALL ATTACHMENTS TO ROOF, MOUNTING BRACKETS & HARDWARE MEET OR EXCEED NYS Southold,NY 11971 CODE REQUIREMENTS 5.INSTALLATION TYPICALLY MAINTAINS 7/8 INCH SPACING BETWEEN MODULES 6.SIZES OF STRUCTURAL MEMBERS THAT WERE NOT ACCESSIBLE FOR DIRECT MEASUREMENT PROJECT#: ARE BASED ON OBSERVATIONS OF ACCESSIBLE MEMBERS, CONSTRUCTION DEPTH OR PROJ.PHASE: PERMIT BOTH IN ADDITION TO KNOWLEDGE OF STANDARD CONSTRUCTION PRACTICES AT THE DATE: B TIME OF CONSTRUCTION B DESIGNED BY: ED 7. THIS DOCUMENT CERTIFIES THAT THE ROOF STRUCTURE HAS BEEN CHECKED FOR WIND, CHECKED BY: GS SNOW, UNBALANCED SNOW, LIVE AND DEAD LOADS BASED ON ASCE 7-10 CHAPTER 30- SCALE: NTS WIND LOADS - COMPONENTS AND CLADDING (C&C)AND FOR CONFORMANCE WITH THE TITLE: 2020 RESIDENTIAL CODE OF NEW YORK STATE.THIS CERTIFICATION DOES NOT APPLY TO STRUCTURAL ANY ADDITIONAL ROOF ALTERATIONS AFTER THE DESCRIBED INSTALLATION A 8.THIS ROOF STRUCTURE AS SHOWN IS ADEQUATE TO SUPPORT THE PROPOSED LOADS A SHEET: 9.REFER TO STRUCTURAL LETTER FOR SITE SPECIFIC AND ROOF SURFACE DATA S-02 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER NOTES: , SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR TEL:516-837-3459 _ ELECTRIC SYSTEM) FAX:516-706-1789 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN www.empower-solar.com STANDARD INVERTER ASSEMBLY: SERVICE PANEL USING'SPLIT-BOLT CONNECTOR' H 3.IN SOME CASES POWER FOR DATA MONITORING ENCLOSURE MAYBE PROPERTY OFOWERCEO HEREINISTHO SOLE H PROPERTY OF EMPOWER CES.I.I.C.UNAUTHORIZED REPRODERIVED FROM MAIN SERVICE PANEL MATERIAL IS ST OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT 4.CONNECT UTILITY SIDE TO PANEL LUGS PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL 5.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 6.SIZE GEC AND EGC AS PER NEC 250.66,NEC 250.122 RESPECTIVELY 7.PROTECT GEC AND EGC SUBJECT TO PHYSICAL DAMAGE AS PER NEC G SOLAR 250.64(6),NEC 250.120(C) G 1 8.FINAL SCHEMATIC SPECIFIC TO THIS INSTALLATION AVAILABLE UPON ARRAY /� REQUEST P,-�,- 0 F N, GORY p INVERTER(S) AC DISCONNECT r (D F AR 064531 E E �c�7SS I ot4P�- STANDARD EXTERIOR INTERCONNECTION: STANDARD INTERIOR INTERCONNECTION: D D REV: DESCRIPTION: DATE: PROJECT NAME: INTERIOR EXTERIOR INTERIOR EXTERIOR Michael Kleiman PROJECT LOCATION: 230 Old Shipyard Lane, MAIN c SERVICE TAP M 1 BREAKER SERVICE M c MAIN Southold,NY 11971 PANEL ENCLOSURE O PANELETTE PANEL O PROJECT#: UTILITY UTILITY PROJ.PHASE: PERMIT METER METER DATE: B B DESIGNED BY: ED 1 CHECKED BY: GS SCALE: NTS TITLE: ELECTRICAL A A SHEET: SE-01 1 2 3 4 5 6 1 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 ENCLOSURE UTILITY NEMA 3R METER EMPOWER SOLAR BRANCH B BRANCH A O AUSTIN BLVD o 1558 (8)SPR-425W MODULES (10)SPR-425W MODULES TO MAIN TO ISLAND PARK,NY TOTAL DC STC POWER:3.40 kW TOTAL DC STC POWER:4.25 kW SERVICE UTILITY TEL:516-837-334545 9 (8)ENPHASE IQ7HS MICRO INV (10)ENPHASE IQ7HS MICRO INV FAX:516-706-1789 TOTAL AC POWER:3.072 kW TOTAL AC POWER:3.84 kW PANEL GRID www.empower-soIar.com AC4 CONTINUEAS CONTINUEAS THE INFORMATION DISCLOSED HEREIN IS THE SOLE H REQUIRED FOR INV.... REQUIRED FOR INV.... SUNPOWER H PROPERTY OF EMPOWER CES.LLC.UNAUTHORIZED M TERIAL IS STRICTLY SPECIFIED STRINGING SPECIFIED STRINGING DATA REPRODUCTION OR DISTRIBUTION OF THIS AC DISCONNECT PRIOR SPECIFIC WRITTOEN ITED PERMIISSIION AC1 AC1 MONITORING 100A,2P CB PROFESSIONAL SEAL L1 L2 N (1)SPR425W MODULE (1)SPR425W MODULE /'1 G 20A,2PCB (1)ENPHASE MICRO INV. INV.2 (1)ENPHASE MICRO INV. INV.2 G G 20A,2P C13 AC1 AC1 AC3 (1)SPR425W MODULE (1)SPR-425W MODULE 20A,2P CB O F N�ry (1)ENPHASE MICRO INV. INV.1 (1)ENPHASE MICRO INV. INV.1 Ll Li O F ACI ACI U) TO RACKING G AC2 O . GROUND G E NEMA 3R A.Q 34531 � (1)#6 AWG,EGC ENCLOSURE E ��SSIONP�� AC COMBINING MLO PANEL 1 -PHASE 120/240V D D REV: DESCRIPTION: DATE: PROJECT NAME: LABEL DESCRIPTION LABEL DESCRIPTION ACI SPR AC CABLE AC2 1-1/2"PVC KLEIMAN RESIDENCE (2)#12 AWG (4)#10 AWG (1)#10 AWG,EGC PROJECT LOCATION: C AC3 3/4"PVC AC4 1-1/2"PVC C 230 OLD SHIPYARD LANE (3)#10 AWG (3)#6 AWG SOUTHHOLD,NY 11971 (1)#10 AWG,EGC (1)#4 AWG,GEC PROJECTM PROJ.PHASE: PERMIT DATE: 07108/2022 B B DESIGNED BY: IV CHECKED BY: XX SCALE: NTS TITLE: NOTES: THREE LINE ELECTRICAL SCHEMATIC 1.NEUTRAL 8 GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR ELECTRIC SYSTEM) 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN SERVICE PANEL USING IRREVERSIBLE SPLICE TOTAL SYSTEM SIZE:7.65 kW A 3.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) (18)SPR-425W MODULES SHEET: A 4.SIZE GEC AND EGC AS PER NEC 240.66,NEC240.122 RESPECTIVELY 5.USE MC ONLY IF INCLUDED GEC IS ADEQUATELY SIZED. (18)ENPHASE IQ7HS MICRO-INV. SE-02 1 2 3 4 1 5 6 7 8 9 10 11 12 13 M SUNP ®WER° 420-440W Residential AC Module SunPower'Maxeon•Technology Built specifically for use with the SunPower Equinox°system,the only fully integrated solar solution designed, engineered,and warranted by one company. Highest Power AC Density Available. The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest efficiency AC solar panel available? E c E S E E 'I i Part of the SunPower Equinox'Solar System • Compatible with Highest Lifetime Energy and Savings mySunPowerT"^ monitoring Designed to deliver 60% more energy over 25 years in • Seamless aesthetics real-world conditions like partial shade and high temperatures.' i I 150% r - --- 140% _ ___130% - - -- - - - - - 1;0% SUNPOIEW 0- 120na Up to �W—.000F v i i oaa 60% i00% More 90% Lifetime w 8ON EnerQ/ Conventional Panel `m i � 7M 0 5 10 15 20 25 Factory-integrated Microinverter Years of Operation • Highest-power integrated AC module in solar i Best Reliability, Best Warranty • Engineered and calibrated With more than 42.6 million and 15 GW modules deployed around by SunPower for SunPower ! the world, SunPower technology is proven to last.That's why we AC modules stand behind our module and microinverter with the industry's I best 25-year Combined Power and Product Warranty. M-Series: M440 I M435 M430 M425 I M420 SunPower° Residential AC Module AC Electrical Data Inverter Model:Type H(Enphase IQ7HS) @240 VAC @208 VAC Max.Continuous Output Power(VA) 384 369 Nom.(L-L)Voltage/Range3(V) 240/211-264 208/183-229 Max.Continuous Output Current(Arms) 1.60 1.77 Max.Units per 20 A(L-L)Branch Circuit4 10 9 CEC Weighted Efficiency 97.0% 96.5% Nom.Frequency 60 Hz Extended Frequency Range 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor(adjustable) 0.85(inductive)/0.85(capacitive) DC Power Data Warranties,Certifications,and Compliance SPR-M440- SPR-M435- SPR-M430- SPR-M425- SPR-M420- 25-year limited power warranty H-AC _H-AC H-AC H-AC H-AC Warranties 25-year limited product warranty Nom.Power'(Pnom)W 440 435 430 425 420 UL 1741/IEEE-1547 Power Tolerance +5/-0% UL 1741 AC Module(Type 2 fire rated) UL 61730 Module Efficiency 22.8% 22.5% 22.3% 22.0% 21.7% UL 62109-1/IEC 62109-2 FCC Part 15[ Css Temp.Coef.(Power) -0.29%/aC CES 0003 Class BB Shade Tolerance Integrated module-level max.power point tracking CAN/CSA-C22.2 NO.107.1-01 CA Rule 21(UL 1741 SA)5 Certifications (includes VoltNar and Reactive Power Priority) and UL Listed PV Rapid Shutdown Equipment? Tested Operating ConditionsCompliance Enables installation in accordance with: Operating Temp. -400 F to+185OF(-40aC to+85'C) NEC 690.6(AC module) Max.Ambient Temp. 1220F(500C) NEC 690.12 Rapid Shutdown(inside and outside the a Wind:125 psf,6000 Pa,611 kg/m2 back array) Max.Test Load Snow:187 psf,9000 Pa,917 kg/m2 front NEC 690.15 AC Connectors,690.33(A)-(E)(1) Max.Design Load Wind:75 psf,3600 Pa,367 kg/m2 back When used with AC module Q Cables and accessories Snow:125 psf,6000 Pa,611 kg/M2 front (UL 6703 and UL 2238)7: Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) •Rated for load break disconnect PID Test 1000 V.IEC 62804 Mechanical Data Packaging • • • Solar Cells 66 Maxeon Gen 6 Modules per pallet 25 Front Glass High-transmission tempered glass with anti-reflective coating Packaging box dimensions 75.4 x 42.2 x 48.0 in. Environmental Rating Outdoor rated (1915 x 1072 x 1220 mm) Frame Class 1 black anodized(highest AAMA rating) Pallet gross weight 1300.7 Ib(590 kg) Weight 48 Ib(21.8 kg) Pallets per container 32 Recommended Max. Net weight per container 41,623 Ib(18,880 kg) Module Spacing 1.3 in.(33 mm) 73.7 In 1 Based on datasheet review of websites of top 20 manufacturers per Wood Mackenzie US PV Leaderboard Q3 2021. I [1872 mm] �I FRAME PROFILE 2 Maxeon 435 W,22.5%efficient,compared to a Conventional Panel on same-sized arrays(260 W,16%efficient, approx.1.6 m2),7.9%more energy per watt(based on PVSyst pan files for avg.US climate),0.5%/yr slower A degradation rate Qordan,et.al."Robust PV Degradation Methodology and Application."PVSC 2018). gH E Grounding Holes 3 Voltage range can be extended beyond nominal if required by the utility. 4 Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. CE n 5 Factory set to IEEE 1547a-2014 default settings.CA Rule 21 default settings profile set during commissioning. o m ~ 6 Standard Test Conditions Ill 000 W/m=irradiance,AM 1.5,25'Q.All DC voltage is fully contained within the module. a (A)Long Side:1.3 in(32 mm) 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12;and C22.1-2015 Rule 64-218 Rapid Short side:0.9 in(24 mm) Shutdown of PV Systems,for AC and DC conductors;when installed according to manufacturers instructions. 7 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. Please read the safety and installation instructions for details. See www.sunpower.com/company for more reference information. Specifications included in this datasheet are subject to change without notice. 02022 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,EQUINOX and U` G DNOromumm weuarrt MYSUNPOWER are trademarks or registered trademarks of SunPower Corporation in the U.S.MAXEON is a Me NOO 539973 RevB registered trademark of Maxeon Solar Technologies,Ltd.For more information visit www.maxeon.com/legal. LISTED E1BJ0 Module Fire Performance:Typo 2 January 2022 1-800-SUNPOWER ;s •• • .. - 's..3 - .. . .�'.�"x �:'q.ri, '.7..:rn'. ..i .. ' 'r.;�•eY+i�. � .,`t_.. kms,. �� �'���� ` 0 Simple and Fast Installation Integrated module-to-rail grounding I Pre-assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates consistent,even module spacing UL 2703 Listed integrated grounding Flexible Design _— Addresses nearly all sloped residential roofs " Design in landscape and portrait with up to 8' fir ` rail span IN Pre-drilled rails and rail splice Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and#1 mounting aesthetics Elegant Simplicity Best-in-class system aesthetics Premium,low-profile design SunPower° InvisiMountTM is a SunPower-designed Black anodized components rail-based mounting system. The InvisiMount system Hidden mid clamps and new capped,flush addresses residential sloped roofs and combines faster end clamps installation time, design flexibility, and superior aesthetics. Part of Superior System The InvisiMount product was specifically envisioned and • Built for use with SunPower DC and AC modules engineered to pair with SunPower modules. The resulting Best-in-class system reliability and aesthetics New optional rooftop transition flashing,rail- system-level approach amplifies the aesthetic and mounted J-box,and wire management rail clips installation benefits—for homeowners and for installers. Combine with SunPower modules and SunPower EnergyLink°monitoring app sunpower.com Datasheet a' • • •• Module'/Mid Clamp and Rail Module'!End Clamp and Rail ON e r Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly(for X systems only) I Vi .n e n siMount Op rating Conditions, Mid Clamp Black oxide stainless steel 300 series 63 g(2.2 oz) Temperature -40°C to 90°C(-40°F to 194°F) End Clamp Black anodized aluminum 6000 series 110 g(3.88 oz) • 3000 Pa uplift Max.Load(LRFD) 6000 Pa downforce Rail Black anodized aluminum 6000 series 830 g/m(9 oz/ft) Rail Splice Aluminum alloy 6000 series 830 g/m(9 oz/ft) Ground Lug 304 stainless steel '•• ••• -• • D e •• Assembly106.5 g/m(3.75 oz) (A2-70 bolt;tin-plated copper lug) Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment • • •• ' ,• Universal interface for other roof attachments Uplift 664lbf Mid Clamp Shear 540lbf • • Uplift 899 Ibf 25-year product warranty End Clamp Warranties Shear 220 Ibf 5-year finish warranty Rail Moment:upward 548 Ibf-ft UL 2703 Listed Moment:downward 580 Ibf-ft Certifications Class A Fire Rated Moment:upward 548 Ibf-ft Rail Splice Moment:downward 580 Ibf-ft Roof Attachment Hardware Uplift 10001bf • ntles L-foot F7Rr to roof attachment hardware manufacturer's documentation. Shear 390 Ibf ' Module frame that is compatible with the InvisiMount system required for hardware interoperability. z SunPower recommends that all Equinox"',InvisiMount"',and AC module systems always be designed using the SunPower Design Tool.If a designer decides to instead use the component capacities listed in this document to design a system,note that the capacities shown are Load and Resistance Factor Design(LRFD) design loads,and are NOT to be used for Allowable Stress Design(ASD)calculations;and that a licensed Professional Engineer(PE)must then stamp all calculations. Should you have any questions please contact SunPower Technical Support at 1-800-SUNPOWER(1-800-786-7693). sunpower.com Co 2017 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo,EQUINOX,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. 509506 RevE All other trademarks are the property of their respective owners.Specifications included in this datasheet are subject to change without notice. 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER SO.LAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 o TEL:516-837-3459 r RESIDENTIAL FAX:516-706-1789 www.empower-solar.cDm H SOLAR PROJECT OnNIDRCEicUNUTHIZDH PRorERWFEPOWEs L. ATHORE REPRODUCTION OR DISTRIBUTION OF THIS PROJECT TEAM. MATERIAL SPECIFIC WRITTPROHIEN PERMISSION N PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL OWNER: Michael Kleiman G SOF NEw P'C ORY D S�0 tI PHONE: (917)547-8853 CD d� ENGINEER OF RECORD: LU F � SOLAR INSTALLER: GREGORY SACHS,PE r Z EMPOWER SOLAR Z 4589 AUSTIN BLVD N 1 •' °a.y _ 4589 AUSTIN BLVD ISLAND PARK,NY 11558 A �p 4 5 3 �� ISLAND PARK,NY 11558 PHONE:516-837-3459 �FESSIONP E •. PHONE:516-837-3459 E 230 old°ghipyartl Ln;-` Scut OK NY 1-1.977 D oti��• D REV: DESCRIPTION: DATE: ' PROJECT LOCATION DATA: SHEET INDEX: PROJECT NAME: Michael Kleiman ADDRESS:230 Old Shipyard Lane, ST-01 COVER SHEET Southold,NY 11971 S-01 EQUIPMENT LOCATIONS .5-02 STRUCTURAL PROJECT LOCATION: c ` 'ti SE-01 ELECTRICAL c 230 Old Shipyard Lane, `= t. °� s�• Southold,NY 11971 SCTM:1000-064.00-02.00-050.000 PROJECT#. � �►;.,� - - PROJ.PHASE: PERMIT �. s } DATE: B \'a B DESIGNED BY: ED CHECKED BY: GS - - SCALE: NTS MAP ' TITLE: COVER SHEET A A SHEET: ST-01 1 2 3 4 5 6 7 8 9 10 11 12 13 , [\\\y�r�j� I�I^�' 1r C E � lJ E SII I��i� SEP 13 2022 '� J BUILDNG DEPT To1rw,.OF SC 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 o TEL:516-837-3459 FAX:516-706-1789 W WW.em p o w e r-sola r.c o m THE INFORMATION DISCLOSED HEREIN IS THE SOLE H H PROPERTY OF EMPOWER CES,LLC.UNAUTHORIZED REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT DRIVEWAY PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL 4 pF NEW ' RY DS,90��r -- EQUIPMENT LEGEND: MODULES 0 = NLL 5 r uj z F p UTILITY METER 2 0 0'q;53 �3 INVERTERS T�T PSSkT I I I m �NP� E 4❑ SOLAR DISCONNECT E MAIN SERVICE PANEL SETBACK LEGEND D ❑ p REV: DESCRIPTION: DATE: 36"CLEAR PATH PROJECT NAME: KLEIMAN RESIDENCE 1 ® 18"RIDGE SETBACK SOUTH-WEST-1 ROOF: PROJECT LOCATION: C 17 SUNPOWER 425W-ACPV PANELS 3 230 OLD SHIPYARD TOTAL POWER:7.225 kW C SOUTHHOLD,NY 19 NE ORIENTATION:230°;PITCH:18° ® ACCESS ROOF z TYPE 1:FLUSH MOUNT rn PROJECT SOLAR ACCESS:95% PROD.PHASE: 6017 SE: PERMIT TSRF:86°/D DATE: 08/22J2022 B B DESIGNED BY: ED CHECKED BY: GS SCALE: NTS TITLE: EQUIPMENT LOCATIONS ROOFLAYOUT A A NOT TO SCALE SHEET: S-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER SOLAR 4589 AUSTIN BLVD SUNPOWER MODULES ISLAND PARK,NY 11558 o ON INVISIMOUNT RACKING TEL:516-837-3459 SHINGLES FAX:516-706-1789 www.em power-sol ar.com INFORMATION DISCLOSED HEREIN H H PRO ERTY OFPWd ENIER CES,LLC.UNAUTHORIZED RAFTERS REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL F NEly y G 411 � w FFTYPICAL ROOF SECTION !� r =: NOT TO SCALE Os?��3 �. SUNPOWER PANEL SPECS �G� sCs E MODULE POWER(Wdc) QTY MODEL# LENGTH WIDTH DEPTH WEIGHTTABLE S-1.1:MAX.ATTACHMENT SPACING E SPR-425 17 SPR-A-SERIES-AC 72.2" 40.0" 1.57" 46.5 LB PPORTRAIT: 64" LANDSCAPE: 8'-0" SPR-E/X-SERIES-AC 61.4" 41.2" 1.81" 42.9 LB D D REV: DESCRIPTION: DATE: NOTES: PROJECT NAME: 1. TOTAL SYSTEM DC POWER:7.225 kW 2.RACKING SYSTEM INSTALLED IN ACCORDANCE WITH CODE-COMPLIANT INSTALLATION Michael Kleiman MANUAL 3.ATTACHMENTS TO BE SECURED TO ROOF ASSEMBLY USING 5 mm STAINLESS STEEL SCREWS PROJECT LOCATION: C AND/OR 5/16"STAINLESS STEEL LAG BOLTS SPACED ACCORDING TO TABLE S-1.1 c 230 Old Shipyard Lane, 4. ALL ATTACHMENTS TO ROOF, MOUNTING BRACKETS & HARDWARE MEET OR EXCEED NYS Southold,NY 11971 CODE REQUIREMENTS 5.INSTALLATION TYPICALLY MAINTAINS 7/8 INCH SPACING BETWEEN MODULES 6.SIZES OF STRUCTURAL MEMBERS THAT WERE NOT ACCESSIBLE FOR DIRECT MEASUREMENT PROJECTik ARE BASED ON OBSERVATIONS OF ACCESSIBLE MEMBERS, CONSTRUCTION DEPTH OR PROJ.PHASE: PERMIT BOTH IN ADDITION TO KNOWLEDGE OF STANDARD CONSTRUCTION PRACTICES AT THE DATE: B TIME OF CONSTRUCTION B DESIGNED BY: ED 7. THIS DOCUMENT CERTIFIES THAT THE ROOF STRUCTURE HAS BEEN CHECKED FOR WIND, CHECKED BY: GS SNOW, UNBALANCED SNOW, LIVE AND DEAD LOADS BASED ON ASCE 7-10 CHAPTER 30- SCALE: NTS WIND LOADS -COMPONENTS AND CLADDING (C&C) AND FOR CONFORMANCE WITH THE TITLE_ 2020 RESIDENTIAL CODE OF NEW YORK STATE.THIS CERTIFICATION DOES NOT APPLY TO STRUCTURAL ANY ADDITIONAL ROOF ALTERATIONS AFTER THE DESCRIBED INSTALLATION A 8.THIS ROOF STRUCTURE AS SHOWN IS ADEQUATE TO SUPPORT THE PROPOSED LOADS A SHEET: 9.REFER TO STRUCTURAL LETTER FOR SITE SPECIFIC AND ROOF SURFACE DATA S-02 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER NOTES: SOLAR 4569 AUSTIN BLVD ISLAND PARK,NY 11558 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR TEL:516-837-3459 ELECTRIC SYSTEM) FAX:516-706-1789 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN www.empower-solar.com STANDARD INVERTER ASSEMBLY: SERVICE PANEL USING'SPLIT-BOLT CONNECTOR' THE INFORMATION DISCLOSED HEREIN IS THE SOLE H 3.IN SOME CASES POWER FOR DATA MONITORING ENCLOSURE-MAYBE H PROPERTY OFEMPOWERCES,LLC.UNAUTHORD'ED REPRODUOF THIS DERIVED FROM MAIN SERVICE PANEL MATERIAL IS STRICTLY PROHIBITEDION ORNWITHOUT 4.CONNECT UTILITY SIDE TO PANEL LUGS PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL 5.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 6.SIZE GEC AND EGC AS PER NEC 250.66,NEC 250.122 RESPECTIVELY — — 7.PROTECT GEC AND EGC SUBJECT TO PHYSICAL DAMAGE AS PER NEC G SOLAR 250.64(B),NEC 250.120(C) 1 8.FINAL SCHEMATIC SPECIFIC TO THIS INSTALLATION AVAILABLE UPON ARRAY /\ REQUEST ,t ?,YD. co �_ INVERTER(S) AC * � . •`• k; DISCONNECT r r { " = -: W F m F( -' w Ga4�3'� A E E STANDARD EXTERIOR INTERCONNECTION: STANDARD INTERIOR INTERCONNECTION: D D REV: DESCRIPTION: DATE: PROJECT NAME: INTERIORtENCLOSUR XTERIOR INTERIOR EXTERIOR Michael Kleiman PROJECT LOCATION: C c 230 Old Shipyard Lane, SERVICEMAIN O 1 BREAKER SERVICE O MAIN Southold,NY 11971 PANEL PANELETTE PANEL PROJECT&. UTILITY UTILITY PROJ.PHASE: PERMIT METER METER DATE. B B DESIGNED BY: ED CHECKED BY: GS SCALE: NTS TITLE: ELECTRICAL A A SHEET: SE-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 ENCLOSURE UTILITY NEMA 3R METER EMPOWER SOLAR BRANCH B BRANCH A M4569 AUSTIN BLVD (8)SPR-425W MODULES (9)SPR-425W MODULES TO MAIN TO ISLAND PARK,NY 11558 TOTAL OC STC POWER:3.40 kW TOTAL DC STC POWER:4.25 kW SERVICE UTILITY TEL:516-837-3459 (8)ENPHASE IQ7HS MICRO INV (10)ENPHASE IQ7HS MICRO INV PANEL GRID FAX:516-706-1789 TOTAL AC POWER:3.072 kW TOTAL AC POWER:3.84 kW www.empower-soIar.com "AAC.4 CONTINUEAS CONTINUE AS HEREIN ISTHE SOLE H REQUIRED FOR INV.... REQUIRED FOR INV.... SUNPOWER H PROPERTYF EMPOWER CESTION ,LLC.UNAUTHORIZED REPRODUCTION OR DISTRIBUTION THIS AC DISCONNECT MATERIAL IS STRICTLY PROHIBITED WITHOUT HOUT SPECIFIED STRINGING SPECIFIED STRINGING DATA MONITORING PRIOR SPECIFIC WRITTEN PERMISSION AC1 AC1 100A,2P CB PROFESSIONAL SEAL L1 L2 N (1)SPR-425W MODULE (1)SPR-425W MODULE n G 20A,2P CB (1)ENPHASE MICRO INV. 1�•2 (1)ENPHASE MICRO INV. INV-2 G n OF NE�ti 1_ 20A,2P B O ACI AC1 AC3 (1)SPR-425W MODULE (1)SPR-425W MODULES r `' (1)ENPHASE MICRO INV. INV.1 (1)ENPHASE MICRO INV. INV.I F AC1 AC1 n 01 F r _ —08453 TO RACKING G Ac n GROUND NEMA3R E (1)#6 AWG,EGC ENGLOSLFRE n E ;fl u AC COMBINING MLO PANEL 1 -PHASE 120/240V D D REV: DESCRIPTION: DATE: PROJECT NAME: LABEL DESCRIPTION LABEL DESCRIPTION AC1 SPR AC CABLE AC2 1-1/2"PVC KLEIMAN RESIDENCE (2)#12 AWG (4)#10 AWG (1)#10 AWG,EGC PROJECT LOCATION: C AC3 3/4"PVC AC4 1-1/2"PVC C 230 OLD SHIPYARD LANE (3)#10 AWG (3)#6 AWG SOUTHHOLD,NY 11971 (1)#10 AWG,EGC (1)#4 AWG,GEC PROJECT#: PROJ.PHASE: PERMIT DATE: 07/08/2022 B B DESIGNED BY: IV CHECKED BY: XX SCALE: NTS TITLE: NOTES: THREE LINE ELECTRICAL SCHEMATIC 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR ELECTRIC SYSTEM) 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN SERVICE PANEL USING IRREVERSIBLE SPLICE TOTAL SYSTEM SIZE:7.225 kW A 3.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 17 SPR-425W MODULES 4.SIZE GEC AND EGC AS PER NEC 240.66,NEC240.122 RESPECTIVELY ( ) SHEET: 5.USE MC ONLY IF INCLUDED GEC IS ADEQUATELY SIZED. (17)ENPHASE IQ7HS MICRO-INV. SE-02 1 2 3 4 5 6 7 8 9 10 11 12 13 nn SUNPWER° 420-44OW Residential AC Module SunPower'Maxeon'Technology Built specifically for use with the SunPower Equinox°system,the only fully integrated solar solution designed,engineered,and warranted by one company. Highest Power AC Density Available. The patented,solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest efficiency AC solar panel available.' � E E Lr m� `n`o olarger Part of the SunPower ' Equinox*Solar System • Compatible with Highest Lifetime Energy and Savings mySunPowerT"^ monitoring Designed to deliver 60% more energy over 25 years in • Seamless aesthetics real-world conditions like partial shade and high temperatures.2 1501 r———— ----- --------- ------ la0se 130% UP to i } 110 s 60% 100% More I - v 40% Lifetime so, Energy Conventional Panel `m I T 70% 60% 0 5 10 15 20 25 Factory-integrated Microinverter nears of operation • Highest-power integrated AC module in solar Best Reliability,Best Warranty _ i • Engineered and calibrated With more than 42.6 million and 15 GW modules deployed around b SunPower for SunPower y the world, SunPower technology is proven to last.That's why we AC modules j stand behind our module and microinverter with the industry's I best 25-year Combined Power and Product Warranty. Datasheet M-Series: M4401 M435 I M4301 M425 I M420 SunPower° Residential AC Module AC Electrical Data Inverter Model:Type H(Enphase IQ7HS) @240 VAC @208 VAC Max.Continuous Output Power(VA) 384 369 Nom.(L-L)Voltage/Range3 M 240/211-264 208/183-229 Max.Continuous Output Current(Arms) 1.60 1.77 Max.Units per 20 A(L-L)Branch Circuit' 10 9 CEC Weighted Efficiency 97.0% 96.5% Nom.Frequency 60 Hz Extended Frequency Range 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor(adjustable) 0.85(inductive)/0.85(capacitive) DC Power Data Warranties,Certifications,and Compliance SPR-M440- SPR-M435- SPR-M430- SPR-M425- SPR-M420- •25-year limited power Warranty H-AC H-AC H-AC H-AC H-AC Warranties .25-year limited product warranty Nom.Power'(Pnom)W 440 435 430 425 420 UL 1741/IEEE-1547 UL 1741 AC Module(Type 2 fire rated) Power Tolerance +5/-0% UL 61730 Module Efficiency 22.8% 22.5% 22.3% 22.0% 21.7% UL 62109-1/IEC 62109-2 Temp.Coef.(Power) -0.29%/°C FCC Part 15 Class B •ICES-0003 Class B Shade Tolerance Integrated module-level max.power point tracking CAN/CSA-C22.2 NO.107.1-01 CA Rule 21(UL 1741 SA)s Certifications (includes VolWar and Reactive Power Priority) and UL Listed PV Rapid Shutdown Equipment' Tested Operating ' ' • Compliance Enables installation in accordance with: Operating Temp. -40°F to+185'F(-40°C to+85°Q NEC 690.6(AC module) Max.Ambient Temp. 1220F(50°C) NEC 690.12 Rapid Shutdown(inside and outside the e Wind:125 psf,6000 Pa,611 kg/m2 back array) Max.Test Load Snow:187 psf,9000 Pa,917 kg/m2 front NEC 690.15 AC Connectors,690.33(A)-(E)(1) Max.Design Load Wind:75 psf,3600 Pa,367 kg/m2 back When used with AC module Q Cables and accessories Snow:125 psf,6000 Pa,611 kg/m2 front (UL 6703 and UL 2238)1: Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) •Rated for load break disconnect PID Test 1000 V:IEC 62804 Mechanical Data • •Configuration Solar Cells 66 Maxeon Gen 6 Modules per pallet 25 Front Glass High-transmission tempered glass with anti-reflective coating Packaging box dimensions 75.4 x 42.2 x 48.0 in. Environmental Rating Outdoor rated (1915 x 1072 x 1220 mm) Frame Class 1 black anodized(highest AAMA rating) Pallet gross weight 1300.7 Ib(590 kg) Weight 48 Ib(21.8 kg) Pallets per container 32 Recommended Max. Net weight per container 41,623 Ib(18,880 kg) Module Spacing 1.3 in.(33 mm) 73.7 In 1 Based on datasheet review of websites of top 20 manufacturers per Wood Mackenzie US PV Leaderboard Q3 2021. I (1872 mm] I FRAME PROFILE 2 Maxeon 435 W,22.5%efficient,compared to a Conventional Panel on same-sized arrays(260 W,16%efficien4 approx.1.6 m2),7.9%more energy per watt(based on PVSyst pan files for avg.US climate),0.5%/yr slower degradation rate gordan,et.al."Robust PV Degradation Methodology and Application."PVSC 2018). i n Grounding Holes 3 Voltage range can be extended beyond nominal if required by the utility. 4 Limits may vary.Refer to local requirements to define the number of microinverters per branch In your area. c E ^� 5 Factory set to IEEE 1547a-2014 default settings.CA Rule 21 default settings profile set during commissioning. o H . ❑ 6 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25'C).All DC voltage is fully contained within the module. o (A)Long Side:1.3 In(32 mm) 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12;and C22.1-2015 Rule 64-218 Rapid Short Side:0.9 In(24mm) Shutdown of PV Systems,for AC and DC conductors;when installed according to manufacturers instructions. 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. Please read the safety and installation instructions for details. See www.sunpower.com/company for more reference information. Specifications included in this datasheet are subject to change without notice. 02022 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,EQUINOX and U` r+iwsA.mwxrumrc MYSUNPOWER are trademarks or registered trademarks of SunPower Corporation in the U.S.MAXEON is a E N 539973 RevB registered trademark of Maxeon Solar Technologies,Ltd.For more information visit www.maxeon.com/legal. LISTED 1"870 Modula Fire hriorman Type2 January 2022 1-800-SUNPOWER •• • 5t ' �---_:,•-c�-.:c,y J� "' ¢ •�� Simple and Fast Installation - - - ! Integrated module-to-rail grounding Pre-assembled mid and end clamps Levitating mid clamp'for easy placement- Mid clamp width facilitates consistent,even module spacing UL 2703 Listed integrated grounding Flexible Design �--- Addresses nearly all sloped residential roofs _ — Design in landscape and portrait with up to 8' rail span Pre-drilled rails and.rail splice Rails enable easy obstacle management Customer-Preferred Aesthetics #1 module and#1 mounting aesthetics Elegant Simplicity Best-in-class system aesthetics Premium,low-profile design SunPower° InvisiMountTm is a SunPower-designed Black anodized components rail-based mounting system.The InvisiMount system Hidden raid clamps and new capped,Flush addresses residential sloped roofs and combines faster end clamps installation time, design flexibility, and superior aesthetics. Part of Superior System The InvisiMount product was specifically envisioned and • Built for use with SunPower DC and AC modules , engineered to pair with SunPower modules.The resulting Best-in-class system reliability and aesthetics New optional rooftop transition flashing,rail- system-level approach amplifies the aesthetic and mounted J box,and wire management rail clips installation benefits—for homeowners and for installers. Combine with SunPower modules and SunPower EnergyLine monitoring app M sunpower.com _I�IIIIIII61i►Illllllll61111 �= . Datasheet , ® , „4 InvisiMount • •• Module'/Mid Clamp and Rail Module'/End Clamp and Rail Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly(for DCsystems only) L I' VisiMount Component Do-tat Mid Clamp Black oxide stainless steel 300 series 63 g(2.2 oz) Temperature -40°C to 90°C(-40°F to 194°F) End Clamp Black anodized aluminum 6000 series 110 g(3.88 oz) 3000 Pa uplift Max.Load(1-RFD) 3000 Pa downforce Rail Black anodized aluminum 6000 series 830 g/m(9 oz/ft) Rail Splice Aluminum alloy 6000 series 830 g/m(9 oz/ft) Ground Lug 304 stainless steel Roof, ••s _ s• Assembly (A2-70 bolt,tin-plated copper lug) 106.5 g/m(3.75 oz) Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Universal interface for other roof attachments InViSimoupt Component ® Capacities2 Uplift 664 lbf Mid Clamp Shear 540 lbf • • Uplift 899 lbf 25-year product warranty End Clamp Warranties Shear 2201bf 5-year finish warranty Rail Moment:upward 548 lbf-ftUL2703 Listed Moment:downward 580 lbf-ft Certifications Class A Fire Rated Moment:upward 548 lbf-ft Rail Splice Moment:downward 580 Ibf-ft Roof Attachment Hardware Uplift 1000 lbf L-foot Shear 390 lbf Refer to roof attachment hardware manufacturer's documentation. 'Module frame that is compatible with the InvisiMount system required for hardware interoperability. z SunPower recommends that all EquinoxTM,InvisiMounP,and AC module systems always be designed using the SunPower Design Tool.If a designer decides to instead use the component capacities listed in this document to design a system,note that the capacities shown are Load and Resistance Factor Design(LRFD) design loads,and are NOT to be used for Allowable Stress Design(ASD)calculations,and that a licensed Professional Engineer(PE)must then stamp all calculations. Should you have any questions please contact SunPower Technical Support at 1-800-SUNPOWER(1-800-786-7693). sunpower.com O 2017 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo,EQUINOX,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. 509506 RevE All other trademarks are the property of their respective owners.Specifications included in this datasheet are subject to change without notice. Datasheet R.,