Loading...
HomeMy WebLinkAbout49488-Z Assn sons FOX RESIDENCE DRAWINGLIST 470 WIGGINS LANE 470 WIGGINS LANE GREENPORT,NY 11944 A1.00 DRAWING LIST,ABBREVIATIONS, SYMBOLS, &NOTES A2.00 NOTES&ENERGY CODE COMPLIANCE G R E E N P O RT, N Y A3.00 DEMOLITION PLAN A4.00 CONSTRUCTION PLAN TRUE SCTM#-1000-35.-4-28 NORTH NOTE:DO NOT SCALE FROM DRAWINGS TAX MAP NO.1000-35.4-28 # ISSUE/REVISION DATE .00 FILING SET 06.01.2023 SYMBOLS REGULATORY NOTES ABBREVIATIONS 1. THIS APPLICATION FOR BUILDING PERMIT IS FILED WITH THE A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD r-LEVEL TOWN OF SOUTHOLD BUILDING DEPARTMENT,IN ALT ALTERNATE DRAWN BY:J.LACHAPELLE THIRD FLOOR CONFORMANCE WITH THE TOWN CODE CHAPTER 144. APP. APPLIANCE(S) HM HOLLOW METAL CHECKED BY:J.LACHAPELLE O WINDOW lfEL. +31'-3° HT HEIGHT 2. THE CONTROLLING CODE IS THE 2020 BUILDING CODE OF NEW B.O. BY OTHER HW HOT WATER `-ELEVATION ABOVE 0'-0" YORK STATE AND THE 2020 ENERGY CONSERVATION CODE OF NOTE:DRAWING MAY BE PRINTED AT REDUCED SCALE O DOOR NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. C/C CENTER TO CENTER MECH. MECHANICAL 1 ELEVATION NUMBER CLG CEILING MTL METAL LaChapelle Architecture PLLC O PARTITION TYPE A6 SHEET NUMBER 3. REFERENCE HEREIN TO 'BC' SHOULD BE CONSTRUED TO MEAN CMU CONCRETE MASONRY UNIT P.O.Box 1251 THE APPLICABLE BUILDING CODES OF NEW YORK STATE. CONIC CONCRETE PTD PAINTED Mattituck,NY 11952 CONT. CONTINUOUS (646)251-5058 jake@lachapellearchitecture.com 4. THIS SINGLE-FAMILY HOME OCCUPANCY CLASSIFICATION IS CONT'D CONTINUED RCP REFLECTED CEILING PLAN A3 1 DETAIL NUMBER RESIDENTIAL GROUP R-3 UNDER BC CHAPTER 3. A4 SHEET NUMBER D.H. DOUBLE HUNG O.C. ON CENTER 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE V(B) DIM. DIMENSION (UNPROTECTED WOOD FRAME) UNDER BC TABLES 601 AND 602. DIA. DIAMETER SIM. SIMILAR ,?,ED pRc DISC. DISCONTINUOUS S.S. STAINLESS STEEL 6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED DWG DRAWING STL. STEEL ,�� �- l� <<` J HEREIN IS COMPLIANT WITH ALL APPLICABLE LAWS,CODES, �A AND REGULATIONS. ELEC. ELECTRIC TYP. TYPICAL STAIR DIRECTION LABELS ENG. ENGINEER EQ. EQUAL V.I.F. VERIFY IN FIELD 00 UP DN INSPECTIONS EXIST. EXISTING W/ WITH �T��- 03393��0�� SC FL FLOOR WD. WOOD OF SMOKE+CARBON MONOXIDE DETECTOR SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE N REQUIREMENTS OF BCNYS 1704&1705. SMOKE AND CO DETECTORS SHALL COMPLY SCOPE O F WORK DRAWING LIST, WITH UL 268,7th ADDITION FRAMING ABBREVIATIONS, PLUMBING MATCH LINE ROUGH ELECTRIC THE GENERAL INTENT OF THE WORK IS TO RENOVATE THE KITCHEN OF SYMBOLS, & NOTES CENTER LINE INSULATION AND CAULKING THIS EXISTING HOUSE, ENLARGE THE OPENING FROM THE KITCHEN TO ENERGY CODE COMPLIANCE THE LIVING ROOM,AND MOVE THE LAUNDRY FACILITIES. NO CHANGE SHEET NO: v BREAK LINE FINAL OF USE OR OCCUPANCY IS PROPOSED. A100 SHEET 1 OF 4 L � GENERAL NOTES GENERAL NOTES GENERAL NOTES FOX RESIDENCE 1. ALL WORK TO BE PERFORMED BY LICENSED TECHNICIANS TO 7. THE STRUCTURAL MODIFICATIONS TO THE HOUSE INCLUDED 13. AS REQUIRED BY ECCNYS R503.1.4 NEW LIGHTING SYSTEMS MUST ACCOMPLISH THE WORK AS OUTLINED IN THIS SET OF HEREIN MAKE THIS A LEVEL 2 ALTERATION UNDER EXISTING CONFORM TO SECTION R404.1:ALL NEW FIXTURES WILL CONTAIN 470 WIGGINS LANE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK.ALL BUILDING CODE (EBC)CHAPTER 6.REQUIREMENTS OF BC HIGH-EFFICIENCY LAMPS. GREENPORT,NY 11944 PLUMBING AND ELECTRICAL WORK SHALL BE CERTIFIED BY CHAPTER 7 AND 8 APPLY AS A RESULT.CONTRACTOR SHALL PERSONS LICENSED IN THEIR TRADES,WHO SHALL ARRANGE CAREFULLY OBSERVE THE REQUIREMENTS OF SECTION 806. 14. CONTRACTOR TO SCHEDULE AND PROVIDE ACCESS REQUIRED FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.ALL FOR ALL INSPECTIONS.WORK MUST REMAIN ACCESSIBLE AND WORK SHALL BE DONE CAREFULLY AND NEATLY, IN A 8. STRUCTURAL OBSERVATION IS NOT REQUIRED UNDER BC 1704.6 EXPOSED UNTIL INSPECTED AND ACCEPTED IN WRITING BY THE SYSTEMATIC MANNER. BECAUSE THE BUILDING IS NOT IN THE INDICATED RISK INSPECTOR. TRUE CATEGORIES AND NOT A HIGH-RISE BUILDING. NORTH 2. IN ADDITION TO THE REQUIREMENTS OF THE APPLICABLE 15. CONTRACTOR MUST COMPLY WITH ALL BUILDING DEPARTMENT BUILDING CODES,ALL WORK MUST CONFORM TO FIRE 9. PROPOSED GWB FINISHES MUST COMPLY WITH BC CHAPTER 8. RULES OF OPERATION(SUCH AS HOURS OF ACTIVITY)AND DEPARTMENT REGULATIONS, UTILITY COMPANY TAPED, PRIMED,AND PAINTED GWB IS ALLOWED UNDER BC 803 INSURANCE REQUIREMENTS. REQUIREMENTS,AND BEST TRADE PRACTICES. AND QUALIFIES AS A CLASS-A MATERIAL WITH FLAME SPREAD INDEX LESS THAN 25 AND SMOKE-DEVELOPED INDEX BELOW 450. 16. CONTRACTOR SHALL NEITHER INTERRUPT NOR RELOCATE 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE THIS EXCEEDS THE REQUIREMENTS OF BC TABLE 803.13 FOR THIS BUILDING SERVICES WITHOUT WRITTEN REQUEST TO THE OWNER TAX MAPNO.1000-35.-0-28 FIELD PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY OCCUPANCY R-3. AND RECEIPT OF WRITTEN CONSENT. a ISSUE/REVISION DATE DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT. 10. INTERCONNECTED SMOKE AND CARBON MONOXIDE DETECTION 17. CONTRACTOR SHALL FILE ALL NECESSARY CERTIFICATES WITH THE .00 FILING SET 06.01.2023 EQUIPMENT MUST BE ADDED IN CONFORMANCE WITH 'EXISTING DEPARTMENT OF BUILDINGS, PAY ALL FEES,OBTAIN ALL PERMITS 4. CONTRACTOR SHALL TAKE THEIR OWN DIMENSIONS AND FIELD BUILDING CODE'SECTION 804, IF NOT ALREADY PRESENT IN THE AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY VERIFY ALL DATA CONTAINED HEREIN.THE DIMENSIONAL DATA BUILDING. AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED. CONTAINED IN THIS DRAWING SET ARE FOR INFORMATION ONLY.THE BUILDING IS NOT SQUARE OR PLUMB SO VARIATION 11. THE WORK PROPOSED HERE MUST CONFORM TO ECCNYS R503 18. CONTRACTOR SHALL COORDINATE WITH OWNER'S SURVEYOR IN EXISTS IN THE DIMENSIONS OF THE EXISTING BUILDING.AS A REQUIREMENTS FOR ALTERATIONS. ADVANCE TO PROVIDE FOUNDATION SURVEY AS SOON AS RESULT DIMENSIONS OF NEW CONSTRUCTION MAY VARY FROM CONCRETE IS PLACED,AND SUBMIT TO SOUTHOLD BUILDING THOSE SHOWN. CONTRACTOR SHALL NOTIFY ARCHITECT OF 12. IN ACCORDANCE WITH R503.1.1.2 EXISTING CEILING,WALL,OR DEPARTMENT. DRAWN BY:J.LACHAPELLE DISCREPANCIES AS THEY ARISE. FLOOR CAVITIES EXPOSED DURING CONSTRUCTION OF AN CHECKED BY:J.LACHAPELLE ALTERATION NEED NOT MEET THE REQUIREMENTS OF THE 19. PRIOR TO COMMENCING OPERATIONS ON SITE THE 5. MINOR DETAILS NOT SHOWN OR SPECIFIED, BUT NECESSARY ECCNYS, PROVIDED THAT THE EXPOSED CAVITIES ARE FILLED w/ CONTRACTOR SHALL PROVIDE BOTH OWNER AND ARCHITECT NOTE:DRAWING MAY BE PRINTED AT REDUCED SCALE FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK INSULATION. 'ACORD' INSURANCE FORM LISTING THE FOLLOWING PARTIES AS SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE ADDITIONALLY INSURED: DRAWINGS. VICTORIA&DANIEL FOX LaChapelle Architecture PLLC LACHAPELLE ARCHITECTURE PLLC P.O.Box 1251 6. CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES THE CONTRACTOR MAY NOT BEGIN SITE OPERATIONS OF ANY Mattituck,NY 11952 WITH REQUIREMENTS OF LOCAL AUTHORITIES AND OWNER. KIND UNTIL THE ABOVE IS PROVIDED. (646)251-5058 jake@lachapellearchitecture.com LIGHT FIXTURE SCHEDULE �C ID FIXTURE TYPE MAKE/MODEL TEMPERATURE WET LOCATION FULL CUTOFF NOTES ����ACHq� y� AA EXTERIOR SCONCE TBD MAX.3,000K YES YES LANTERN SCONCE SIMILAR TO EXISTING ON HOUSE-LED <<� n BB INTERIOR RECESSED WAC R3ARDL-F-827-WT 2,700K NO N/A WHITE FINISH,TRIMLESS-TAPED INTO CEILING GWB FINISH-LED 7` � p CC INTERIOR PENDANT TBD 2,700K NO N/A SELECTION BY OWNER-LED s '` DD UNDER CABINET TBD MAX.3,000K NO N/A SELECTION BY OWNER-LED ���� 03393 o EE OF N EV`j '�/ WINDOW & DOOR SCHEDULE, ENERGY CODE COMPLIANCE NOTES& ENERGY U-FACTOR/R-VALUE SHGC CODE COMPLIANCE ID ASSEMBLY MAKE/MODEL DIMENSIONS HARDWARE NOTES QTY ECCNYS PROPOSED ECCNYS PROPOSED A CASEMENT WINDOW ANDERSEN 400 32"W x 50"h PER OWNER LOW-E4 1 0.32 0.30(PASS) 0.40 0.28(PASS) SHEET NO: B FIXED WINDOW ANDERSEN 400 32"x 72" PER OWNER LOW-E4 1 0.32 0.30(PASS) 0.40 0.28(PASS) A2mOO 1 SLIDING PATIO DOOR ANDERSEN 72"x 84" PER OWNER TEMPERED GLAZING 1 0.32 TBD 0.40 TBD SHEET 2 OF 4 _ - - - _- - - - .- " `—' — _ _ _' - - - _ .— _ - - _ _ — PROJECT NORTH FOX D.H.32"W x 50"H D.H.32"W x 50"H j D.H.32"W x 50"HD.H.32"W x 50"H - RESIDENCE v 470 WIGGINS LANE PODER = I GREENPORT,NY 11944 N I SCALE: 1/4"=1'-0" UP X 2100MMA DEMOLISH = I PARTITION NORTH LIVING EXISTING PARTITION AT ROM y y y y y y y y y I TAX MAP NO.1000-35.4-28 yyyyyyy7 # ISSUE/REVISION DATE y y y y y y y y y y y y y y y y y y y y y y y y T y y y y y I .00 FILING SET 06.01.2023 i i i y y y y y y y y y y y y y y y y y y y y y iii su y Ce) X0000,,,,,,,,,,,,,,,,,,,,, y0000y0yyyyyyyyyyyyyyyyyyyyyyyy - - I DRAWN BY:J.LACHAPELLE •,y ,yy•,•,•.y•., BEDROOM yyyyyyyyyyyy yyyyyzyyy yzyyyyyyyyyy — HALL y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y I CHECKED BY:J.LACHAPELLE EXISTING CARPETING yyyyyyyyyyyyyyy%yyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy 7777 y7777777777777777'/.7 y77 y7777 NOTE:DRAWING MAY BE PRINTED AT REDUCED SCALE y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y C, y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y U' yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy I LaChapelle Architecture PLLC X y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy P.O.Box 1251 y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y CV yyyyyyyyyyyyyyyy0000 0yy yyyy0yy I Mattituck,NY 11952 IM= yy yy yyy yy y..y.y.y.y.y y,yy y,y yy yy yy yy yy yy yy yyyy yy yy yy yy yy (646)251-5058 jake@lachapellearchitecture.com = EF�E���MOLISK EXISTING WOOD tiRF O�r �r .�r r�� FLOORS ��5��LAC HgAcc% =� I I = �_�__ r �r� I FAMILY CD � 03393 ————— �rrrr �r � r��rsrv�� �a rrr������r �~� X I �F NE\;4 to EXISTING EXISTING SHEET VINYL r =~ I I _ FIRST FLOOR FLOORING I � �������rr�----r- �~ I~ I I PLAN 13-1 1 pk HLUL _ -- _-- 41-42 I SHEET NO: — _ — 72"W x 80"H SLIDER — _ — _ — (2)D.H.32"W x 36"H — — _ — _ _ —94"W x 80"H SLIDER — — — — — A3mOO SHEET 3 OF 4 j -` PROJECT NORTH FOX RESIDENCE 470 WIGGINS LANE GREENPORT,NY 11944 PO ER SCALE: 1/4"=1'-0" n UP / I EXISTING CD PARTITION TRUE NORTH FOYER I LIVING � _________ J \ III DEMOLISH 000 ... PROTECT EXIST. I PARTITION AT ROM '%% WOOD FLOORING .. \ .',.... .. TO REMAIN TAX MAP N0.100D35.428 ..... NEW # ISSUE/REVISION DATE ..... ...\• I PARTITION 5'-6" .00 FILING SET 06.01.2023 ljj LIGHT '/.'/.'/.'/.'/.'/.'/.. ............ •, 3-472 i FIXTURES; ... ,, ..... ... . . . . . . / REPLACE ; \ ¢BB SEE , .. ',.. . �..„ FOLDING I FLOORING SCHEDULE COUNTER' .........................�c..... j 00 ..........' .........�i;:E. WfYSHER/ DRAWN BY:J.LACHAPELLE BEDROOM1. UL. DYER 4 0 4 6 ' f 1 CHECKED BY J LACHAPELLE ............................... ............................... I Q NOTE:DRAWING MAY BE PRINTED AT REDUCED SCALE ,..,,.. ........•„ •,.•,•,...,•,..•,.•,•,,...... PAN R” LaChapelle Architecture PLLC .....,.,.,,.,,,•,.,,.,.',,.,,..,.,., zoo.•,.• 2'-10�' I P.O.Box 1251 ............................... ................................ I �bN Mattituck,NY 11952 ............................... , — — — -- — — — r c _ _ _ _ _ _ _ _- _- _ _ _ I (646)251-5058 jake@lachapellearchitecture.com UPPER CABINETS - ------ i;l NEW 6"PLANK COUNTERTOPu j I� j` j———— -'' N I FLOORING;TYPE NEW PORCELAIN TILE �_ _�_j_`� , I --_-- - ---- SELECTED BY OWNER R�D FLOOR(OR AS SELECTED3'-6" 5'-6" I FURR OUT WALLAS ��5� CACy kC BY OWNER) I - 2 } NECESSARY FOR I L / 1 CONTINUOUS SURFACE 24"KOHLER FARM I / SINK#K-5664 - - --- e _ - - BB r - — J I �W X I li `n / I I ��N i4 ill FAMILY I I i o I �0 �I � •$� - _� � I I iv KITCHE � I I A N i III FNEV � M BB 1 I III Cf) U \ _ ALL B 88 / ( ) E I L PROPOSED TO Y g x 94' Y) E S FIRST FLOOR Vii , O U I PLAN WINE REFRIG. - L__JI 1, 1 ol- 6 -4'-3-" �5' " �2'-0" 3 " 7-1 ' 1 11- SHEET NO: — — — 72"W x 80"H SLIDER — — — — —FIXED 32"WW x 72"H — — — —94"W x 80"H SLIDER — _ — — — A4mOO �--/ SHEET 4 OF 4