HomeMy WebLinkAbout24402-z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-25985 Date: 09/23/98 THIS CERTIFIES that the building NEW DWELLING Location of Property: 230 WILLIS CREEK DR MATTITUCK (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 115 Block 17 Lot 17.9 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated AUGUST 25, 1997 pursuant to which Building Permit No. 24402-Z dated OCTOBER 7, 1997 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ONE FAMILY DWELLING WITH ATTACHED TWO CAR GARAGE AND FRONT WOOD PORCH AS APPLIED FOR. The certificate is issued to JAMES F DONOHUE (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-97-0092 05/11/98 ELECTRICAL CERTIFICATE NO. N-456781 06/19/98 PLUMBERS CERTIFICATION DATED 05/27/98 HARDY PLUMBING & HEATING Bu ding Insp &tor Rev. 1/81 roan` NO. s TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, N. Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) N° 24402 Z Date .......................�........ .................... 1 Permission is hereby gra tw. ..... ..� . . � ..... .cif. oho . .<..Q�.l. ....t� ..��a.... .................. .... .. ........................./ ..� .7. ... . .... .................` ... to . . .... ... . . .. . .. . , .!I. .. ..., . . ........r. ..... ......... .... ...�:� . ...... . ....G'.. ........ ............................................................................... ............. ..............,......... ........................... atpremises located at�J..P`. .. .... ............. ................... ................... County Tax Map No. 1000 Section .. .. Block ........� ..... Lot No. —12"J'.-.. pursuant to application dated ........ .. .......... ..;2.,r............... 19.5 7, and approved by the Building Inspector. Ins ect r . Fee $.�� ..... f . . ...... .... .......... nspe Building I tor Rev. 6/30/80 r- Form No. 6 IF n TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802.,_ TOWN O."SuU3:�r` APPLICATION FOR CERTIFICATE OF OCCUPANCY �, {� A. This application must be filled in by typewriter OR ink and submitted to the building inspector with the following: for new building or new use: 1. Final survey of -property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form) . 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00. Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Buildine - $100.00 3. Copy of Certificate of Occupancy - 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $115.00, Commercial $15.00 Date . . 7/.? /.Ti . . . . . . . . . . . . . . . . . . . . . . . . . . . New Construction. .)/n .... Old Or Pre-existing Building. . .. .. . . . . . . . . . . . Location of Property..Z30...W.U.6;..,:fir:`.`. . . lJ�.��: ... .. . . . . . . . . .. . . .�I�! `. . . . . . . . . . . House No. Street Hamlet Onwer or Owners of Property.. cb�::�S .. :r!Q <. . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . County Tax Map No 1000, Section. ..t45. . . . . ..Block. . . . `7. . . . . . . . . .Lot. . . . . f.?(C. . . . . . . . . . . . Subdivision. VI.Gw . .'':?�./&i,f. ?!cC. . . .Filed Map. .0 77 . . .Lot. . . .( . . . . . . . . . . . . . . . . . Permit No. 24W. Z. Z. . .Date Of Permit. . . . . . . . . . . . . . . .Applicant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Health Dept. Approval. j7 J . ! . . . 1 1.�. . . . . . .Underwriters Approval. . . . . . . . . . . . . . . . . . . . . . . . . PlanningBoard Approval. . . . . ... . . . . . . . .. . . . . . . . Request for: Temporary Certificate. . . . . . . . . Final Cert Fee Submitted: $. . . . .0?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPLICANT THE NEW YORK BOARD OF FIRE- UNDERWRITERS PAGE 1 1195205 BUREAU-OF ELECTRICITY F 40 FULTON STREET,NEW YORK, NY 10038 Date JUNE 19,1998 Application No. on file 15307798/98 N 456781 THIS CERTIFIES THAT 4, only the electrical equipment as described below and introduced by the applicant named on the above application number is in the premises of MILLER BLUFF CONSTRUCTION, LOT#8 WILLS CREEK DRIVE, MATTITUCK, NY in the following location; ® Basement ® Ist Fl. ® 2nd Fl. GAR/OUT Section 115 Blockl7 Lot 17.9 was examined on JUNE 15,1998 and found to be in compliance with the National Electrical Code. FIXTURE RECEPTACLES SWITCHES FIXTURES RANGES COOKING DECKS OVENS DISH WASHERS EXHAUST FANS OUTLETS INCANDESCENT FLUORESCENT I OTHER AMT. I K.W. I AMT. I K.W. AMT. K.W. AMT. I K.W. AMT. H.P. 50 54 45 50 1 11. 1 8.8 1 1.2 2 F DRYERS FURNACE MOTORS FUTURE APPLIANCE FEEDERS SPECIAL REC'PT.1 TIME CLOCKS BELL UNIT HEATERS MULTI-OUTLET DIMMERS AMT. K.W. OIL H.P. GAS H.P. AMT. NO. A.W.G. AMT. AMP. AMT. AMPS. TRANS. AMT. H.P. SYSTEMS AMT. WATTS T1 SYSTEMS OF FEET 4 F 2 20 1 SERVICE DISCONNECT NO.OF S E R V I C E METER NO.OF CC COND. A.W.G A',Wl' A.W.G. AMT. AMP. TYPE' EQUIP. 1 0 2W 1 0 3W J 0 3W S 0 4W PER0 OF CC.GOND. NO.OF Hi-LEG O HI-LEG NO.OF NEUTRALS OF NEUTRAL 1 200 CB 1 X 1 4/0 1 2/0 OTHER APPARATUS: SPECIAL RECEPT. AMP.30-1 PADDLE FANS-4 WHIRLPOOL BATH-1 3 TON CENTRAL A/C-1 4 TON CENTRAL A/C-1 MOTORS:1-3 H.P. ,1-4 H.P. ,2-F H.P. FANELBOARDS:2-1 CTR. 60 - G.F.C.I:-8 <<< Continued on Page 2 »> GENERAL MANAGER Per This certificate must not be altered in any manner; return to the office of the Board If incorrect. Inspectors may be identified by their credentials. COPY FOR BUILDING DEPARTMENT. THIS COPY OF CERTIFICATE MUST NOT BE ALTERED IN ANY MANNER. THE NEW YORK BOARD OF FIRE UNDERWRITERS PAGE 2 1195205 BUREAU OF ELECTRICITY F 40 FULTON STREET, NEW YORK, NY 10038 Date JUNE 19,1998 Application No. on file 15307798/98 N 456781 THIS CERTIFIES THAT only the electrical equipment as described below and introduced by the applicant named on the above application number is in the premises of MILLER BLUFF CONSTRUCTION, LOT#8 WILLS CREEK DRIVE, MATTITUCK, NY in the following location; ® Basement ® 1st Fl. ® 2nd Fl. GAR/OUT Section 115 Blockl7 Lot 17.9 was examined on JUNE 15,1998 and found to be in compliance with the National Electrical Code. FIXTURE RECEPTACLES SWITCHES FIXTURES RANGES COOKING DECKS OVENS DISH WASHERS EXHAUST FANS OUTLETS INCANDESCENT FLUORESCENT OTHER AMT. K.W. AMT. K.W. AMT. K.W. AMT. K.W. AMT. H.P. DRYERS FURNACE MOTORS FUTURE APPLIANCE FEEDERS SPECIAL REC'PT. TIME CLOCKS BELL UNIT HEATERS MULTI-OUTLET DIMMERS AMT. K.W. OIL H.P. GAS H.P. AMT. NO. A.W.G. AMT. AMP. AMT. AMPS. TRANS. AMT. H.P. SYSTEMS AMT. WATTS NO.OF FEET SERVICE DISCONNECT NO.OF METER E R V I C E METER NO.OF CC COND. A.W.G. A.W',6. A.W.G. AMT. AMP. TYPE EQUIP. 1 0 2W 1 0 3W 3 0 3W 3 0 4W Pr 0 OF CC.COND. NO.OF HI-LEG OF NO.OF NEUTRALS OF NEUTRAL FT I I j I i i OTHER APPARATUS: SOUTH FORK ELECTRIC LIC.#4080 L L 562 PLEASURE DRIVE FLANDERS, NY, 11901 GENERAL MANAGER 11 Per This certificate must not be altered in any manner;return to the office of the Board If Incorrect.Inspectors may be identified by their credentials. COPY FOR BUILDING DEPARTMENT. THIS COPY OF CERTIFICATE MUST NOT BE ALTERED IN ANY MANNER. TEL. 763-1802 r c, ' CDS. TOWN Or SOUTHOLD 1,� ,; :-•:,'' :c OFFICE OF BUILDINGS INSPECTOR P.O. DO:7 128 'f' TOWN I=.•'.LL SOUTHOLD, N.Y. 11971 w C E R T I F I C A T I O N Date Building Permit No. Owner Dt) KO (please print) (plea&- print) I certify that the solder used in the water supply system contains less than 2110 of 1% lead. 41, � - ��'�-moi �LYIIV �`' P,,L1►/`�� J (plumber ' s signature) Sworn to before me this _day of 19 -Ilotlary Public Nota-_­ I)v!-'.icCaunly EMILY HAMILL Notary Public,State of New York No.01HA5059984 Qualified in Suffolk Coun Commission Expires May 06_7 9� ozg� New York State Department ��cnvironmental Conservation }l Division of Environmental Permits Building 40 - SUNY, Stony Brook, New York 11790-2356 Telephone 15 16) 444-0365 Facsimile (516) 444-0360 John P. Cahill LETTER OF NONJURISDICTION--TIDAL WETLAND Commissioner July 18, 1997 Mr. James Donohue RE: 1-4738-01645/00001 15 Lehigh Lane Donohue Property Farmingviile, NY 11738 Willis Creek Dr., Mattituck Dear Mr. Donohue: SCTM #1000-115-17-17.9 Based on the information you have submitted, the New York State Department of Environmental Conservation has determined that the property landward of the 10 ft. elevation contour as shown on the survey prepared by Young & Young Land Surveyors, dated June 2, 1997 and last revised June 9, 1997 is beyond the jurisdiction of Article 25 Tidal Wetlands. Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661) no permit is required under the Tidal Wetlands Act. Please be advised, however, that no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project (i.e. a 15' to 20' wide construction area) or erecting a temporary fence, barrier, or hay bale berm. Please be further advised that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies. Very truly yours, Permit Administrator MMR cc: Young & Young BMHP File �.•'. f ) � � 1.j ;i zx S: :r: �. � p�yy 45, K -__b �I:T�i"P°^' 4 '.•'�re.l.rt `.1 1y� Board Of Southold Town Trustees SOUTHOLD, NEW YORK ` ty< PERMIT NO. . 1.77Y 8/5 __ DATE: ..... /97._ ISSUED TO ..... . .JAMES...DONOHUE. ...._.,__,. . `�- I � _ IE Pursuant to the provisions of Chapter 615 of the Laws of I� the State of New York, 1893; and Chapter 404 of the Laws of the » State of New York 1952• and the Southold Town Ordinance en- !. titled "REGULATING AND THE PLACING OF OBSTRUCTIONS IN AND ON TOWN WATERS AND PUBLIC LANDS and the r ;j REMOVAL OF SAND, GRAVEL OR OTHER MATERIALS FROM ` LANDS UNDER TOWN WATERS;" and in accordance with the Resolution of The Board adopted at a meeting held on ....7/.30197...... 19 ...97, and in consideration of the sum of $ .150.-0.0 _ _ paid by Miller-5tuffs Constr., for. JAMES_DONOHUE r .. ...... . ....... ......... ........ i of .. .....Mattituc.k..................... N. Y. and subject to the Terms and Conditions listed on the reverse side hereof, j� y - =a of Southold Town Trustees authorizes and permits the following: w �l Wetland Permit to construct a single family dwelling, pool, i patio, etc. , with no off-site fill required and with a 50' non-tut4 non-disturbed buffer area to align with neighbors on both sides ' f `t all in accordance with the detailed specifications as presented in the originating application. 1 " IN WITNESS WHEREOF, The said Board of Trustees here- by causes its Corporate Seal to be affixed and theseresents to be subscribed by a majority of the said Board as of this date. �r O ....\ .. Trustees ,. <.�' w�v.Ilii.'dGu'.cll�u�.,.r_...�`wd.SJ6Wu'.�.';'�.,.x5...��'==�i""`w _is;."'m,��r�r4��'w�' ',r�.�r•.�,�'.rii„di`� " .•v.. 11�'f.� M.`;..:mF.'_. :. . Fti rig '�+% 1 !/ +. '�^'�+%•. i E� i i TERMS and CONDITIONS The Permittee JAMES DONOHUE residing at 15 Lehigh Lane, Farmingville, NY 11738 N. Y., as part of the consideration for the issuance of the Permit does understand and prescribe to the fol- lowing: 1. That the said Board of Trustees and the Town of Southold are released from any and all damages, or claims for damages, of suits arising directly or indirectly as a result of any oper- ation performed pursuant to this permit, and the said Permittee will, at his or her own expense, defend any and all such suits initiated by third parties, and the said Permittee assumes full liability with respect thereto, .to the complete exclusion of the Board of Trustees of the Town of Southold 2. That this Permit is valid for a period of 24 mos. which is considered to be the estimated time required to complete the work involved, but should circumstances warrant, request for an extension may be made to the Board at a later date. 3. That this Permit should be retained indefinitely, or as long as the said Permittee wishes to maintain the structure or project involved, to provide evidence to anyone concerned that auth- orization was originally obtained. 4. That the work involved will be subject to the inspection and approval of the Board or its agents, and non-compliance with the provisions of the originating application, may be cause for revocation of this Permit by resolution of the said Board. 5. That there will be no unreasonable interference with navigation as a result of the work herein authorized. 6. That there shall be no interference with the right of the public to pass and repass along the beach between high and low water marks. 7. That if future operations of the Town of Southold require the removal and/or alterations in the location of the work herein authorized, or if, in the opinion of the Board of Trustees, the work shall cause unreasonable obstruction to free navigation, the said Permittee will be requited, upon due notice, to remove or alter this work or project herein stated without expenses to the Town of Southold. 8. That the said Board will benotified by the Permittee of the completion of the work auth- orized. 9. That the Permittee will obtain all other permits and consents that may be required sup- plemental to this permit which may be subject to revoke upon failure to obtain same. o��g�FFO�,�c Albert J. Krupski, President y. �Gy Town Hall John Holzapfel, Vice President c 53095 Main Road CIO P.O. Box 1179 Jim King Martin H. Garrell y � Southold, New York 11971 Peter Wenczel �0,( �'a� Telephone (516) 765-1892 Fax (516) 765-1823 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD kugust 4, 1997 Young & Young 400 Ostrander Ave. Riverhead NY 11901 Re: JAMES DONOHUE 115-17-17.9 Dear Mr. Wolpert, The following action was taken by the Board of Town Trustees during its Regular Meeting held on July 30, 1997, regarding the above matter: WHEREAS, JAMES DONOHUE, applied to the Southold Town Trustees for a permit under the provisions of the Wetland Ordinance of the Town of Southold, application dated June 25, 1997, and, WHEREAS, said application was referred to the. Southold Town Conservation Advisory Council for their findings and recommendations, and WHEREAS, a Public Hearing was held by the Town Trustees with respect to said application on July 30, 1997, at which time all interested persons were given an opportunity to be heard, and, WHEREAS, the Board members have personally viewed and are familiar with the premises in question and the surrounding area, and, WHEREAS, the Board has considered all the testimony and documentation submitted concerning this application, and, WHEREAS, the structure complies with the standard set forth in Chapter 97-18 of the Southold Town Code, WHEREAS, the Board has determined that the project as proposed will not affect the health, safety and general welfare of the people of the town, 40 sun.uINa uePr. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] 1 CATION [ ] FRAMING [ FINAL [ ] FIREPLACE & CHIMNEY REMARKS: ✓� DATE s �� I8 INSPECTOR U suauINc DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INS TION 1 FRAMING [ FIN LL [ ] FIREPLACE & CHIMNEY ,-REMARKS: 314,�iis s� ���G�-mss • �s-/� � N/1 DATE ` INSPECTOR BUILDING DEPT. INSPECTIO [ ] FOUNDATION IST [ O GH PLBG. [ ] FOUNDATION 2ND [ INSULATION [ ] MING [ ] FINAL [ FIREPLACE & Cn111MNEY REMARKS: �.�• C Lu+.e,G DATE '� lr'$ INSPECTOR�� suauINa DEPT. INSPECTIO [ ] FOUNDATION IST [ ROUGH PLBG. tot,.,) [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: DATE � 27 9 � INSPECTOR BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] F UNDATION 2ND [ ] INSULATION [ FRAMING [ ] FINAL [ ] FIREPLACE 8 CHIMNEY REMIA KS: a DATE � Z� / � INSPECTOR M-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ROUGH PLBG. [ ] F NDATION 2ND [ ] INSULATION ( FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: DATE � � 3//0 suauiNc oar. INSPECTION [ ] F NDATION IST [ ] ROUGH PLBG. ( FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE 8 CHIMNEY REMARKS: M Of fY�wNO1�11 NVIZIR lMV�.{ CI IN TION I"Amawa. DATE �� ��' l` -INSPECTOR _��G� BUILDING DEPT. INSPECTION [ Lj FOUNDATION iST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: r v DATE O INSPECTOR ajkAA.A ,� M-tso2 saLuiNa DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN TION [ ] FRAMING [ FINAL [ ] FIREPLACE 8 CHIMNEY REMARKS: DATE � 3 9S INSPECTOR__�,�ra�; suauiNa DE". INSPECTION [ j FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INS ION [ ] FRAMING �- [_ NAL [ ] FIREPLACE NIMNEY REMARKS: /'lam DATE �� IN8P BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ FINAL [ ] FIREPLACE & CHIMNEY REMARKS: 6t�IJJZA,ZO-.1 DATE ?IIV19fINSPECTOR _ L " A i r tl� .�POW� N� ii /;� //t�l�" RVA i V� ' / 4c- r ''�'�,• r Gam.' 'i1n r BOARD OF HEALTH . . . . . . . . . . . . . . . � -- . ._ _. FORM NO. 1 SETS OF PLANS . . . . . . . . . . . . . . . }�( TOWN OF SOUTHOLD SURVEY . . . . . . . . . . . . . . . . . . . . . . . . BUILDING DEPARTMENT --tCR TOWN HALL EPTIC FORM . . . . . . . . . . . . . . . . . . . AUG 2 51 SOUTHOLD, N.Y. 11971 TEL: 765-1802 NOTIFY: _ -�• . p-f- CALLL3C . Examined � MAIL TO: . .• . 6R" o/ . G� Approved �i ..,J�....., 19 Permit No. 1.1..� .. A J�1:4�- ! C ..J•:E/T ! Disapproveda/c .......................... ... .................................... ilding Inspector)•-••. AP CATION FOR BUILDING PERMIT Date. . . . . . . . . . . . . . . . . 19. . . . INSTRUCTIONS a. This application must be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and giving a detailed description of layout of property must be drawn on the diagram wbich is part of this application. c. The work cowered by this application ray not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such permit shall be kept on the premises available for inspection throuemaut the work. e. No building shall be occupied or used in whole or in part for any purpose whatever until a Certificate of Occupancy shall have been granted by the Building Inspector. APPLICATION IS WEBY MATE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk Canty, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant, or name,. . ifa corporation) `o..#U41 P--Pac ce .•.••(Mailing address of applicant) State whether applicant is owner, lessee agent, architect, engir=•gene al contractor, electrician. plumberor builder. ... .j .A�. .. ......................... . . • <1.�Name of owner of premises ....�1.�.�Q��... .................................................................. (as on the tax roll or lateE'cer. ) If applicant �is�a corporation,r��att�ion, signatu+dulthorized OIL .(Name and title of corporate office Builders License No. ......................... Plumbers License No. ......................... Electricians License No. ..................... Other Trade's License No. .................... 1. Location of land on which proposed work will be done..l:�A.9...MAP HA .......... ...............................................:........................... House Number Street Hamlet County Tax Matp' No. 1000 Section .. 1 5 .l. ......... Block .. ........... Lot . 1•F........ 14 Subdivision qft-.vjW' . °�.Mi4 .U(!�r Filed Map No. ............... Lot ...1........... (Name) 2. State existing use and occupancy of penises and intended use and occupancy of proposed construction: a. Existing use and occupancy .............................................�.�.`........... ........ b. Intended use and occupancy .LWS'7MCT-....4!z 3. Riture of work (d►ec.k whidh applicable): New lkuilding .z.. Addition .......... Repair ............ Removal ............. I .. Alteration.. .......... Demolition ......... Other Work .................................. (Description) 4. Estimated Cost .z1:M.. E1..:... ...... fee ..................... (to be paid on filing this application) 5. If dwelling, nnber of dwelling units .k?. ...... Muri►er of &jelling units on each floor ................ If garage, number of cars ...2.CA4.L.L.AVA,41F............. 6. If Ix►siness, commercial or mixed occupancy, specify nature and extent of each type of use...................... 7. Dimensions of existing structures, if any: Front................ Rear ............... Deptl► ................. height ......................... M mi)er of Stories ...................... Dimensions of sae striActure with alterations or additions: Front ............... Rear ............... Depth .................... height ......... Nnber of Stories ............... 8. Dimensions of entire new construction: Front ..Z Rear Depth L�l, Q. Height .... L'............. ... Naber of Stories ..Z. 9Th5�c4aS... . I• .. 9_ Size of lot: Front .., ............... Rear A 0 P................ Depth }°............. 10. Date of Purchase ..................... Name of Former Owner .��rh �+b 00�N f ...... . II. Zane or use district in whidh premises are situated .............................................................. 12. Does proposed construction violate any zoning law, ordinance or regulation: .PJ3??................... 13. Will lot be regraded ..yes............. Will excess fill be removed from premises: YES ® p 14. Nares of Owner of premises .�l,l!�h^�`1��?Q KYR ........ Address .«.L�!lt. .�,!9.. (t�ntlltlf'�.�,�.f}hone No. t qqy-f:40. Name of Ardhitect .!1�m.:.�J.�?`:`:*'�!. C•... .... Address a1 F' RJAAL�/�ve_ fj �[,H. No. Name of Contractor Mtj ,315• l;0!. RUCI'IOIV.• Address?-9.2% c71 / l!I-t A-Y.Phone No. 7. 15. is this property within 300 feet of a tidal wetland? * YES .✓..... NO .....•„•• *I.F YES, SOUMD 1171N 7RUSIFL-S PCj4ff MAY BE. RCiXIIRf,3). PLOT DIAGRAM Locate clearly and distinctly all buildings, whether existing or proposed, and indicate all set-back dimensions from property lines. Give street and block number or description according to deed, and show street nares and indicate wlietlier interior or corner lot. A-7CAC.44-W 5u(2. 1e ,/ M SIAII's (A. mW Y(Mll(, c� SS (XXJNIY OC ........... .....J A"j*. ..................... ........,Iheing duly sworn, deposes and says that the is the appl.ic:a,►t (tJ.-me of individual signing contract-) alxNe named, - Ikis We ....-E .... �. ..........• .... ........................................... (Contractor, agent, corporate officer., et ) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tnue to the best of his krxmledge and lx--lief; and t.haL the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this ............Q lr%A..day of .�Aone..........19A,.... Notary Public .......A...(X.U�......... ELLINADAMO (Signature of ppiicant) Notary Public,State of New York No.5010707 Qualified in Suffolk County Commission Expires April 5,19� Note:The Bi Fold Series palss doom overlap the hsme around the fireplace.Allow 1/16"clearance;top,bottom and each side when opplyino/strop materlsts. 7 BI-fold Glass Doors P/N 086651 Symphony 38 (Aiumimrm) P/N 096652 Symphony 43 P/N 027711 386F PM 027712 43BF PM 027632 38BF-PB P/N 027633 43OF-PB P/N 026962 38BF-SPB P/N 026963 43BF-SPB "ALL-GLASSTM" P/N 027634 38BF-ABR / BI-Fold Doors P/N 027635 43BF-ABR "ALL-GLASS""" P/N 038952 38C-SPB Twin-Pane Doors P/N 038953 43C-SPB j Bi-Fold Glass Doors P/N 037832 38SBF-BR Twin-Pone P/N 097271 Sonata 38 (Aluminum) P/N 037833 433BF-BR Solid Brass Doors P/N 097272 Sonata 43 NOTE:DIAGRAMS 8 ILLUSTRATIONS NOT TO SCALE Superior reserves the right to make changes at any time,without notice,in design,materials,specifications,prices and also to discontinue colors,styles and products.Consult your local distributor for fireplace code information. Distributed By: SUPE ImmikR a. The Rrepiace Company 4325 Artesia Avenue Printed in U.S.A. Fullerton, CA 92633 ®1992 by Superior Fireplace Company Plants in Fullerton, CA, P/N 097605 REV. C 1/94 Union City,TN Chase Termination Locking Band P/N 002400 LB (Square) P/N 015604 BCS-CT2 Forced Air KK P/N 011781 FAK-1500 0 s' s' s Chase Termination Storm Collar P/N 002013 SC (Round) P/N 021951 BCS-CTDT Fan Adapter KK P/N 016751 CF-ADK P/N 020011 BC8-F6 Combustion Air KR P/N 011761 AK-4 Variable Speed Flashing P/N 020021 BC8-F12 (Less Duct) P/N 011763 AK44LD wall Switch P/N 045571 VSWS O Round Termination P/N 020031 BC8-CTD Take Oft Boot P/N 011771 TOB Refractory Patch Kit P/N 010405 RPK Chase Termination (Square) P/N 020041 BCB-CT1 Forced Air Kit P/N 045421 FAK-3000 Refractory Tint Kit P/N 008988 RTK NOTE:DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 19 r FINISH TO YOUR TASTE SUPERIOR'S ACCESSORY PARTS AND There are a wide variety of"finished looks"for COMPONENTS LIST FOR KC AND KR your KC and KR Series;from formal wall decor SERIES FIREPLACES with elaborate mantels to rustic wood paneling to warm brick facings. The following accessory parts and components are to be used only with your Superior fireplace Only non-combustible materials.like stone,tile, system. Separate installation instructions are brick,etc., may overlap the black front facing packaged with all combustion air kits,forced air but be sure not to interfere with the installation kits and chimney terminations. and operation of glass doors or blockthe upper OOsell Return P/N 022151 BCB-ES30 or lowergrilles.Seal alljoints between the black If you encounter any problems or have ques- Padca9e(30°) P/N 022156 TFID/BCB-E&30 facing and wall surrounds to prevent air intru- tions concerning the installation or application sion. Use non-combustible caulking material of this system,please contact your distributor. only to seal the black metal facing to the sur- For the name of your nearest distributor call: round material on the finished wall. SUPERIOR FIREPLACE COMPANY Combustible materials may project beyond the 4325 Artesia Avenue sides of the fireplace opening as long as they Fullerton,California 92633 are kept within the shaded areas illustrated in 714-521-7302 Ir Figures 54 and 55. Oflset/Ratum Combustible Fireplace Elbow(15°) P/N 019951 BC8-OR15 Materials Model Part Number Weight Allowed In Shaded Area 1. KC-38 P/N 044551 165 lbs. a 3/4' I KC-43 P/N 044552 185 lbs. 3 ° KR-38 PM 044553 165 lbs. 7 31C KR-43 P/N 044554 185 lbs. A_ 8" Min.Distance To Protected Side Wall 15" Min.Distance To Unprotected Side Wall KR-38/KC-38 Models ACCESSORIES Figure 54 Stabilizer P/N 019981 BC8-94 Combustible Fireplace Materials Wall Allowed In Shaded Area 1• 43/4' o 3 " ' 91/2" i J_ Protected Distance Side 18' Min.Distance To P/N 019981 BC8-12 Unprotected Side Wall P/N 019882 BC8-18 P/N 019983 BCO-36 KR-43,/KC-43 Models Chimney Section P/N 019984 BC8-48 Firestop Spacer(Flat) P/N 019931 BC8-FS Figure 55 O Starter Section P/N 036981 BC8-SS Firestop Spacer(30°) P/N 019941 BC8-FS30 18 NOTE:DIAGRAMS&ILLUSTRATIONS NOT TO SCALE s Methods of Determining Hearth Extension and Wall Shield Equivalents Alternative Hearth Extension WARNING: THE CRACK BETWEEN THE nd Wal Shield Mater als To determine the thickness required for any FIREPLACE AND THE HEARTH EXTEN- SIONmaterial when either the k or r values are Listed MUST BE SEALED WITH ANON- known: L TM = Thickness of material in inches Millboara 1/2 WARNING: WHEN INSTALLING THE rM = K value of desired material Alternative ues in,ive a i HEARTH EXTENSION BE CAREFUL NOT = R value of desired material TO BLOCK THE HEAT-CIRCULATING AIR TL = Minimum listed thickness M INLET GRILL ON MODEL KC-38 AND Example:Micore CV230 is to be used with the Common 5FIER . KC-38 fireplace.How thick must this material Cement mortar WARNING: WHEN INSTALLING MODEL be? era ise KR-38 AND KR-43;FIREPLACE MUST BE Using the k formula: RAISED IF HEIGHT OF HEARTH EXTEN- SION EXCEEDS r ABOVE THE BOTTOM Desiredkvalue of desired Min.thickness Micore CV230 0.43 2.33 1/4' UF WFIF MIN up I Required = material(per inch) x o f ypsum Listed Ceraform 126 0.27 3.70 1/4' Thickness k value of listed Material material(per inch) TM(inches) = -R; x TL Example:Superior required that the"R value" .84 for a suitable hearth extension used with the KR-38 be equal to or greater than"R"=r x TL= >- TM(inches) = 0.43' x 1/2'" 1.19 x 1/2'=0.595. It is desired to elevate a 0.84 marble hearth extension to a level of 5 inches or Max.Thidmess Of Hearth Extension more above the floor surface.What combina- When KR Models Are on The Floor Answer using k=0.51 x 1/2'=0.25=1/4' tion of non-combustible materials can be used Using the r formula: to accomplish this? Figure 52 If we use common brick so that the 3-1/2' Desired r value of listed Min.thickness dimension is the height,"R"for the common WARNING: WHEN INSTALLING MODEL Required = material(per inch)x of listed brick becomes: KC-38 AND KC-43;FIREPLACE MUST BE Thickness r value of desired Material RAISED IF HEIGHT OF HEARTH EXTEN- material(per inch) -R-M=r x TM=0.20 x 31/2'=.70 SION EXCEEDS 1-1/2" ABOVE BOTTOM TM(inches) = 1.19 x TL If we use 1/2'of mortar to set the brick,"R"for rM the mortar becomes: TM(inches) = 1.19 x 1/2'*' -R"M=r x TM=0.20 x 1/2'=.10 2.33' giowms When we use 3/4'marble set in 1/2'mortar,"R" ORION— Answer using r=.051 x 1/2'=.025=1/4' for the marble and mortar becomes: s 'value taken from chart 'R"M=r x TM= 0.09 x 3/4' =.068 "minimum thickness per listing 'R"M=r x TM= 0.20 x 1/2' =.10 1 At times it is important to know what combing- Adding up all"R values"we get: 1/r tion of materials are acceptable for use as Max.Thidmess Of Hearth Extension hearth extensions.The"R values"are used to .70+.10+.068+.10=.968 When KC Models Are On The Floor determine acceptable combinations of materi- als because"R values"are additive where rand This would be an acceptable combination of k values are not. material forthe hearth extension since the total Figure 53 _ calculated "R Value" of the materials used "R value"= 1= r x thickness of material used exceeds the required"R Value"of.595. Secure the hearth extension to the floor to k prevent possible shifting. NOTE:DIAGRAMS d ILLUSTRATIONS NOT TO SCALE i7 Always plumb gas line installation per local Superior strongly recommends thatthe CF-ADK Hearth Extensions And Wall Shields codes.Check all connections with soap suds; Adapter Kit be purchased and installed on the leaks will bubble.Never test any gas line con- KC-38 and KC-43 fireplace.This wall help pre- A hearth extension must be installed with all nection with a match or open flame. vent outside intrusion air from entering your fireplaces.It isto protectthefloor in front of the home through the fireplace. fireplace from both radiant heat and sparks. IMPORTANT: RE-PACK INSULATION MATE- The hearth extension must extend 8'beyond RIAL IN SQUARE HOLE AROUND GAS LINE, Note:A 2'airspace must be preserved for all both sides of the fireplace opening and 16' INTERIOR AND EXTERIOR,TO SEAL. combustible materials extending for any con- beyond the front.Use a hearth extension con- tinuous length adjacent to the chimney. structed of a durable non-combustible material This provision is intended only for connection having an equal or greater insulating value of k to a decorative gas appliance incorporating an It is especially important to insulate between =.84BTU-IN/FT2HR-OF or a thermal resistance automatic shut-off device and complying with the studs of an outside chase cavity and under that equals or exceeds r=1.19 HR-OF-FTI/BTU- the Standard for Decorative Gas Appliances for the floor if the floor is above ground level.Do IN. A minimum 3/8' thick non-combustible installation in vented fireplaces,ANSI Z21.60. not place insulation directly against the fire- material is all that is required over a non- Install in accordance with the National Fuel Gas place or chimney system. combustible or slab floor. Code, ANSI 2223.1. This complies with the revised U.L.127 standard. FIREPLACE FINISHES Note:Any1/2'non-combustib/emateria/whose CAUTION:PLUMBING CONNECTIONS SHOULD Mantels and Trim k value is less than.84 or whose r value is more than i.19 is acceptable. ONLY BE PERFORMED BY A QUALIFIED, LI- It is sometimes best to frame your fireplace CENSED PLUMBER.MAIN GAS SUPPLY MUST after it is positioned and the chimney is in- If the fireplace is installed on a combustible BE OFF WHEN PLUMBING GAS LINE TO FIRE- stalled.Frame enclosure for chimney and fire- floor,use the metal safety strips(provided)on PLACE OR PERFORMING SERVICE. place with 2 x 4's(or heavier)lumber. the floor extending half underthe fireplace and If you're installing a gas line,connect it beforehalf under the hearth extension. Note:The header may rest on the two(2)metal the fireplace is framed and enclosed in the spacers on top of the unit but the header must A wall shield is required where a continuous finished wall.The gas knockout is determined not be notched to fit around the spacers. perpendicular side wall is within 15'(18'on the by a 1-1/8' round indentation located at the KR/KC-43 models)of the fireplace opening on bottom and slightly off center in the side ref rac- The KR and KC Series may sit directly on a the KR/KC-38 models.Use a 40'x 40'x 1/2'wall tories.THE KNOCKOUT IS ALWAYS REMOVED combustible surface.A 2'air space is required shield constructed of millboard or a durable, FROM INSIDE THE FIREPLACE. DO NOT RE- between combustible framing and the chim- non-combustible material having an equal or MOVE THE KNOCKOUT UNLESS YOU ARE IN- ney. Combustible mantels and trim may be greater insulating value than K = .84BTU-IN/ STALLING A GAS LINE.If removal is attempted installed 12'above the fireplace opening as per SOFT-HR-OF. from the outer wrapper,side refractory damage NFPA 211,Section 7-3.3.3.and Figure 5O.If a may occur. With a medium-sized hammer, mantel is of a non-combustible material,it is If fireplace is installed diagonally across a 900 lightly tap the surface of the indentation.The exempt from these requirements as long as it corner;no wall shields are required. refractory material is very thin in this area and does not interfere with the installation oropera- is easily removed.Once a small hole has been tion of glass doors or block the inlets and made,continue tapping until you have reached outlets on Models KC-38 and KC-43. suff icientdiameterforthe gas line tofitthrough. wall shield Required The entire knockout does not have to be re- where Lou Than 15" For 35"and 40"Openings moved.Remove insulation in the gas line chan- and 1B"for 15'openings nel. Max. �. qB" CAUTION: WHEN USING THE DECORATIVE GAS APPLIANCE, THE FIREPLACE DAMPER �„ MUST BE SET IN THE FULLY OPEN POSITION. Combustib Mantel and Trim COLD CLIMATE INSULATION J_stible C If you live in a cold climate, it is especially 51/2" Wali covering B importantto seal all cracks around the fireplace A opening with non-combustible material and Fireplace wherever cold air could enter the room.Sur- opening Figure 51 rounding materials must be caulked where it Typical Installation meets the black metal facing of the fireplace to (KC Series Shown) Hearth Extension Dimensions avoid cold air intrusion. Use non-combustible caulking material only on fireplace facing to Figure 50 Opening 38" 43" seal.Also,the outside air inlet duct should be Width wrapped with non-combustible insulation to minimize the formation of condensation. Do A 16' 16' not place insulation materials against chimney B 30.1/4' 35' sections. 16 NOTE:DIAGRAMS 81LLUSTRATIONS NOT TO SCALE C 8' 8' ' OPTIONAL EQUIPMENT Combustion Air Kits Note:Do not terminate combustion air kit in Glass Doors attic space under any circumstances. Use Combustion Air Kit,Model AK-4 orAK-4LD, If glass doors are to be installed on KR and KC with the KR and.KC Series fimplaces.Refer to A Take-Off Boot Adapter,Model TOB,may be Series fireplaces, refer to specific installation installation instructions packed with the air kits used inconjunction with the air kittoreduce the instructions packed with the glass doors.Use for specific installation information.The out- framing dimensions when installing the fire- Superior glass doors Models 38BF,38BF-PB, side air kit must be installed before the fireplace place diagonally in a comer(Figure 49).Refer 38BF-ABR, 38BF-SPB, 38C-SPB, 38SBF-BR, is framed and enclosed in the finished walls. to installation instructions packed with the TOB Sonata 38 and Symphony 38 for Models KR-38 for specific installation information. and KC-38.For Models KR-43 and KC-43 use Outside air drawn into the fireplace supplies air 43BF, 43BF-PB, 43BF-ABR, 43BF-SPB, to the fire for combustion.Only one combus- 43C-SPB,43SBF-BRI Sonata 43 and Symphony tion air duct on the left side of the fireplace is 43.Use of other non-listed glass door on these necessary if installed. fireplaces may constitute a potential fire hazard TOB Adapter and is not recommended. Provision For Outside I I Air I I CAUTION:DO NOT ATTEMPT TO TOUCH THE DOORS WITH YOUR HANDS WHILE THE FIRE- ® I I PLACE IS IN USE. ALWAYS USE DOOR HANDLES.DOORS WILL BECOME VERY HOT 2r WHEN FIREPLACE IS IN USE. WARNING:FIREPLACES EQUIPPED WITH Figure 49 DOORS SHOULD BE OPERATED ONLY WITH THE DOORS FULLY OPEN OR FULLY Figure 48 Forced Air Kits CLOSED. If additional length of duct is necessary, pur- If you are installing a Superior Forced Air Kit, chase locally available U.L.Type 0 or 1 metallic Model FAK-1500orFAK-3000,on Models KC-38 duct. The duct may extend up to 50' in any and KC-43;see the instruction sheet provided direction. with the forced air kit for electrical wiring re- quirements.The fireplace has been pre-wired Note:When installing the airduct vertically,DO at the factory but must be connected to main NOTterminate the ductcloserthan 3'belowthe power supply at the time of installation ifafan chimney top. kit is to be installed later. Use Superior's fan Adapter Kit,Model CF-ADK,to allow the fire- ----LSz�"-- There is a one hand operated shut-off valve place to be connected to the main power sup- Fully Open Or located in the left side of the fireplace opening ply.The electrical connections must be made FulClosed behind the screen.To open,pull out all the way. before the fireplace is framed and enclosed in The combustion air damper should be fully the finished walls. Figure 47 open when, the fireplace is in use and fully closed when the fireplace is not in operation to CAUTION: ELECTRICAL CONNECTIONS prevent outside air from entering your home. SHOULD ONLY BE PERFORMED BY A QUALI- CAUTION:CERTAIN GLASS DOORS OVER- FIED,LICENSED ELECTRICIAN.MAIN POWER LAP THE BLACK METAL FACING OF THE CAUTION:NEVER LOCATED INLET WHERE IT MUST BE OFF WHEN CONNECTING FANS TO FIREPLACE.IFTHE FIREPLACE HAS BEEN CAN BE BLOCKED BYSHRUBS,SNOW DRIFTS, MAIN ELECTRICAL POWER SUPPLY OR PER- FACED WITH NON-COMBUSTIBLE MATE- ETC. NEVER LOCATE INLET IN GARAGE OR FORMING SERVICE. RIALS, THERE MIGHT NOT BE SUFFI- ANY AREA WHERE THERE IS ANOTHER FUEL CIENT CLEARANCE TO INSTALL THE BURNER APPLIANCE OR PRODUCTS EMIT- Variable Speed Wall Switch GLASS DOORS OF YOUR CHOICE. EN- TING COMBUSTIBLE GASES SUCH AS PAINT, SURE ADEQUATE CLEARANCE IS MAIN- GASOLINE, ETC. IN COLD CLIMATES IT IS Refer to the installation instructions provided TAINED AT ALL TIMES SO AS NOT TO RECOMMENDED THATTHE COMBUSTION AIR with the Variable Speed Wall Switch, Model INTERFERE WITH THE INSTALLATION DUCT BE INSULATED. VSWS,for installation details. AND OPERATION OF GLASS DOORS. Outside combustion air ducting may be run GAS LINE CONNECTION upwards or vertically through framing and ceil- ing joists,with the hood installed through an Install only a 1/2'black iron pipe through fire- outsidewalland 3'below the termination.Duct- place wall for connection to a decorative gas ing may also be run downward through floor appliance inside the firebox.Outside,the iron joists and underthe home to a ventilated crawl- pipe connects to a gas shut-off valve recessed space not considered part of the living area of flush into the wall orfloor.The valve should be the home. controlled by a removable valve key for safety. NOTE:DIAGRAMS 81LLUSTRATIONS NOT TO SCALE 15 Return Elbow Max. B2 X � Sz BI M �, Stabilizer 10'Max. `\ St \ St Offset et Ot Elbow Figure 43 Figure 44 Figure 45 Maximum offset of chimney system in the U.S. Step 1. Determine the offset distance where Step 2.Center inner slip section into inner flue is 300.Two offsets must not be assembled to chimney is to pass through the first ceiling- pipe-slip down. form a 600 offset.However,two sets of offset dimension"A".To find this point on your ceil- and return elbows may be used on a single flue ing,first determine the center point for a verti- Step 3.Center outer-locking section over outer system,provided the total height of the system cal chimney following the instructions for ver- chimney pipe.Push down until locking joint has exceeds 25'. tical installation. firmly engaged. Return elbow support straps must be securely Measure height to the ceiling from the top of Step 4. Pull up slightly on return elbow to attached under tension(in shear)to structural fireplace-dimension "B". Use the appropriate ensure locking joint has firmly engaged. framing members above. Do not substitute a Offset Elevation Chart to find dimension "A". BC8-30 Offset Elbow in place of a BC8-E30 Mark point where you will drive your nail to Steps.Secure support straps to framing mem- Return Elbow. show the center pointf or your offset ceiling cut. bers by nailing under tension in sheer. OFFSET CALCULATIONS Step 2.Proceed by using the Straight Up Instal- T lation Instructions for cutting and framing ceil- T ' Step 1.Use Offset Chart to determine amount ing and roof openings. of horizontal offset(A)and height(B)for vari- T ous chimney section assemblies. Note:See framingandDimension Chartforthe 05 sizes of the ceiling and roof openings.The size Step 2.Use"Height of Flue Only"column in The of the roof opening varies with the degree of Vertical Elevation Chart to determine combina- pitch of the roof. tions of chimney used above return elbow to Retum achieve desired heights. Reference Compo- OFFSET ELBOW ASSEMBLY Elbow nents Effective Height Chart in vertical elevation Figure 46 chart section. Offset elbows install the same as chimney sections.First,snap the inner section INTO the Note:The return elbow assembly performs the Step 3. Use Elevation Chart as job estimator preceding inner section of flue.Check connec- same function as a stabilizer. Consider this only.Add necessary f irestop spacers and stabi- tion by pulling up slightly to ensure a tight fit. when determining the need for a stabilizer lizers as required. Firestop spacers must be Next, the outer sections snap lock OVER the used as shown in Figures 22and 23 and stabi- preceding outer section of chimney. Again, Note:Do not apply excessive pressure to any lizers as shown in Figure 29. check outer section by pulling up slightly to subsequent chimney section following return ensure proper connection is made. elbow assembly when installing. Ensure that TO INSTALL OFFSETS each subsequent chimney section is securely First, review the Chimney Offset Elevation RETURN ELBOW ASSEMBLY attached by testing as noted above. Charts and Figures 41 and 42 on page 13 for Return elbows install the same way as round BCB-OR15 OFFSEWRETURN ELBOWS reference. terminations and stabilizers: of last The BC8-OR15 Offset/Return Elbow is prima- Step 1. Hold return elbow over top rily used when fireplace penetrates a 6'thick chimney section. wall. Refer to installation instructions packed 14 NOTE:DIAGRAMS d ILLUSTRATIONS NOT TO SCALE with BC8-OR15 for proper usage. • OFFSET ELEVATION CHART A B BC8-ES30 BC8 BCS BCS BCS BC8 Offset Height Oftel/Return $4 12' 18" 38- 43' Return Elbow (Inches) (Inches) Elbow Stabilizer Flue Flue Flue Flue 4 15 1 0 0 0 0 0 9 1/4 24 1 0 1 0 0 0 Chimney Section(S) 12 1/4 29 1/4 1 0 0 1 0 0 14 1h 1 33 1 1 0 2 1 0 0 1 0 17 1h 38 1/4 1 0 1 1 0 0 21 1/4 44 3144 1 0 0 0 1 0 B 26 1h 54 1 0 1 0 1 0 Offset Elbow� / 27 1/4 55 1/4 1 0 0 0 0 1 A 29 1/2 59 1 0 0 1 1 0 32 1h 63 1/4 1 0 1 0 0 1 - -- 35 1/2 69 1h 1 0 0 1 0 1 37 3'4 73 1h 1 0 2 0 0 1 40 I4 78 1/2 1 0 1 1 0 1 44 1h 85 1 0 0 0 1 1 49 3/4 94 1/4 1 0 1 0 1 1 50 1h 95 1h 1 0 0 0 0 2 52 N 99 1/4 1 0 0 1 1 1 55 3'4 104 /h 1 0 1 0 0 2 58 99 109 -Y4 1 0 0 1 0 2 62 115 1h 1 1 1 2 0 0 2 Figure 41 65 120 1h 1 1 1 1 0 2 68 :'4 127 1 1 0 0 1 2 74 136 1/4 1 1 1 0 1 2 74 N 137 1h 1 1 0 0 0 3 OFFSET ELEVATION CHART (43"SYSTEMS WITH BC8-SS STARTER SECTION) A B BC8-ES30 BC8 BC8 BC8 BC8 BC8 Offset Height OffseVReturn Starter tY 18' 38' 48' (Inches) (Inches) Elbow Section Flue Flue Flue Flue 13 3Y4 32 1/2 1 1 0 0 0 0 Return Elbow I 19 41 1 1 2 0 0 0 22 46 3/. 1 1 1 1 0 0 24 1/2 50 V4 1 1 0 0 1 0 Chimney Section(S) -- -- 27 1/4 56 1 1 0 0 0 1 30 1/4 61 1 1 0 1 1 0 31 62 1/2 1 1 1 0 0 1 Starter Section 32 1h 65 1 1 2 0 0 1 35 1h 70 1/4 1 1 2 0 0 1 B 36 1/4 71 1h 1 1 1 1 0 1 Offset Elbow A 37 72 :Y4 1 1 0 0 1 1 38 1h 75 1h 1 1 1 0 1 1 39 1/4 76 N 1 1 0 0 0 2 ------ 41 1h 80 1/4 1 1 0 1 1 1 42 1/4 81 :4 1 1 1 0 0 2 44 1/2 85 3144 1 1 0 1 0 2 45 1/4 87 1 1 2 0 0 2 47 1/2 91 1 1 1 1 0 2 48 1/4 92 1/4 1 1 0 0 1 2 49 -4 94 % 1 1 1 0 1 2 52 98 N 1 1 0 0 0 3 53 1/2 101 1/4 1 1 0 1 1 2 54 1/4 102 :Y4 1 1 1 0 0 3 Figure 42 55 -'4 105 1/4 1 1 0 1 0 3 56 1h 106 1/2 1 1 2 0 0 3 58 144 110 1h 1 1 1 1 0 3 59 1h 111 3/4 1 1 0 0 1 3 60 1/4 113 1 1 1 0 1 3 NOTE:DIAGRAMS 8 ILLUSTRATIONS NOT TO SCALE 13 VERTICAL ELEVATION CHART (FEET AND INCHES) Height 01 Number Of BC8 Height Of Number Of BC8 Height Of Number Of BC8 Height Of Number Of BC8 Flue Only Flue Lengths Flue Only Flue Lengths Flue Only Flue Lengths Flue Only Flue Lengths Inches Feet 12 18 36 48 Inches Feet 12 18 36 48 Inches I Feet 12 18 36 48 Inches Feet 12 18 36 48 101/2 0101/2 1 0 0 0 2493/4 20 9 39 0 1 0 5 4761/, 39 81/4 1 0 0 10 70234 58 6 39 0 1 1 14 161/2 1 41/2 0 1 0 0 2541/4 21 21/4 2 0 0 5 4821/4 40 21/4 0 1 0 10 708 39 59 0 39 1 0 0 15 21 34 1 939 2 0 0 0 2601/4 21 81/4 1 1 0 5 486 39 40 6% 2 0 0 10 71439 59 634 0 1 0 15 27 39 2 3 39 1 1 0 0 2673'4 22 334 0 0 1 5 492 39 41 03/4 1 1 0 10 7191/4 59111/4 2 0 0 15 341/2 2101/2 0 0 1 0 2781/4 23 21/4 1 0 1 5 5001/4 41 81/4 0 0 1 10 7251/4 60 51/4 1 1 0 15 461/2 3101/2 0 0 0 1 279:Y4 23 3 34 0 0 0 6 510 34 42 6 39 1 0 1 10 73234 61 039 0 0 1 15 51 39 4 33/4 0 1 1 0 2841/4 23 81/4 0 1 1 5 5121/4 42 81/4 0 0 0 11 7431/4 61 111/4 1 0 1 15 57 39 4 939 1 0 0 1 2901/4 24 21/4 1 0 0 6 516 Y4 43 03/4 0 1 1 10 744% 162 0 39 0 0 0 16 6339 5 339 0 1 0 1 2961/4 24 81/4 0 1 0 6 522 39 43 6 39 1 0 0 11 7491/4 162 51/4 0 1 1 15 681/4 5 81/4 2 0 0 1 300 39 25 034 2 0 0 6 5283/4 44 03/4 0 1 0 11 7551/4 62111/4 1 0 0 16 741/4 6 21/4 1 1 0 1 306:Y4 25 6 39 1 1 0 6 5331/4 44 51/4 2 0 0 11 7611/4 63 51/4 0 1 0 16 81 34 6 9 34 0 0 1 1 3141/4 26 21/4 0 0 1 6 5391/4 44111/4 1 1 1 1 0 1 11 76534 63 9 34 2 0 0 16 93 39 7 9 34 0 0 0 2 324 39 27 0 39 1 0 1 6 546 34 45 6 34 0 0 1 11 771 39 64 339 1 1 0 16 981/4 8 21/4 0 1 1 1 3261/4 27 21/4 0 0 0 7 5571/,4 46 51/� 1 0 1 11 7791/4 64111/4 0 0 1 16 1041/4 8 81/4 1 0 0 2 3303/4 27 6 39 0 1 1 6 558 V4 146 639 0 0 0 12 78934 65 934 1 0 1 16 1101/4 9 21/4 0 1 0 2 336 34 28 039 1 0 0 7 5631/4 4611 1/4 0 1 1 11 791 1/4 6511 1/, 0 0 0 17 1143/4 9 6:4 2 0 0 2 342 39 28 6 34 0 1 0 7 5691/4 47 51/4 1 0 0 12 795 39 66 339 0 1 1 16 12039 10 0 39 1 1 0 2 3471/4 2811 1/4 2 0 0 7 5751/4 47111/4 0 1 0 12 801 39 66 9 34 1 0 0 17 1281/4 10 81/4 0 0 1 2 3531/4 29 51/4 1 1 0 7 57934 48 33/4 2 0 0 12 807 39 67 3 39 0 1 0 17 138 39 11 6 39 1 0 1 2 36039 30 03/4 0 0 1 7 5853/4 48 9 34 1 1 0 12 8121/4 67 81/4 2 0 0 17 1401/4 11 81/4 0 0 0 3 3711/4 30111/4 1 0 1 7 5931/4 49 51/4 0 0 1 12 8181/4 68 21/4 1 1 0 17 144 39 12 03/4 0 1 1 2 3723/4 31 039 0 0 0 8 60339 50 3:4 1 0 1 12 825 34 68 93'4 0 0 1 17 15034 12 639 1 0 0 3 3771/4 31 51/4 0 1 1 7 6051/4 50 51/4 0 0 0 13 8361/4 69 81/4 1 0 1 17 15634 13 0 39 0 1 0 3 1 3831/4 1 31 111/4 1 1 0 0 8 6093/4 1 50 934 0 1 1 12 837 39 69 93/4 0 0 0 18 1611/4 13 51/4 2 0 0 3 3891/4 3251/4 0 1 0 8 615 39 51 3 391 0 0 13 8421/4 70 21/4 0 1 1 17 1671/4 13111/4 1 1 0 3 393 34 32 934 2 0 0 8 62139 51 939 0 1 0 13 8481/4 70 81/4 1 0 0 18 17434 14 639 0 0 1 3 399% 33 3 39 1 1 0 8 6261/4 52 21/4 2 0 0 13 8541/4 71 21/4 0 1 0 18 1851/4 15 51/4 1 0 1 3 4071/4 3311 1/4 0 0 1 8 6321/4 52 81/4 1 1 0 13 8583/4 71 6 34 2 0 0 1 18 18634 15 63/4 0 0 0 4 41734 34 9 39 1 0 1 8 639 34 53 3 39 0 0 1 13 864 34 72 0 39 1 1 0 18 1911/, 15111/, 0 1 1 3 4191/4 34111/, 0 0 0 9 6501/4 54 21/4 1 0 1 13 8721/4 72 81/4 0 0 1 18 1971/4 16 51/4 1 0 0 4 423 39 35 339 0 1 1 8 651 39 54 3 39 0 0 0 14 8823/4 73 6 34 1 0 1 18 2031/4 16111/4 0 1 0 4 1 429 3Y4 35 94/4 1 0 0 9 6561/4 1 54 81/4 0 1 1 13 8841/4 73 81/4 0 0 0 19 207 34 1717 3 39 2 0 0 4 4353/4 36 334 0 1 0 9 6621/4 55 21/4 1 0 0 14 888 39 74 0 39 0 1 1 18 213 39 9 34 1 1 0 4 4401/4 36 81/4 2 0 0 9 6681/4 55 81/4 0 1 0 14 894 39 74 6 34 1 0 0 19 2211/4 18 51/4 0 0 1 4 4461/4 37 21/4 1 1 0 9 672 34 56 03/4 2 0 0 14 900 34 75 0 39 0 1 0 19 231 34 19 3 39 1 0 1 4 453 414 37 9 34 0 0 1 9 678 34 56 6 34 1 1 0 14 9051/4 75 51/4 2 0 1 0 19 2331/4 19 51/4 0 0 0 5 4641/4 38 81/4 1 0 1 9 6861/4 57 21/4 0 0 1 14 9111/4 75111/4 1 1 0 19 237 39 19 9 39 0 1 1 4 4653/4 38 939 0 0 0 10 696 39 58 034 1 0 1 14 918 39 76 6 39 0 0 1 19 24334 20 3 34 1 0 0 5 4701/4 39 21/4 0 1 1 9 6981/4 58 21/4 0 0 0 15 12 NOTE:DIAGRAMS&ILLUSTRATIONS NOT TO SCALE " —Less Dan 10, SPECIAL OFFSET INSTRUCTIONS To clear any overhead obstructions,you may 2'Min. offset your chimney system using Superior 300 offset and return elbows.Use two elbows-an Min offset elbow to initiate the offset and a return 10, Min elbow to terminate it.A 300 offset elbow,an- Min in any direction,may be the first compo- nent used off the top of the fireplace flue collar. The offset and return elbows may be attached together,or a section or sections of chimney may be used between,but do not exceed 20'in total length between elbows.If sections of pipe Figure 37 exceed 10' between elbows,a chimney stabi- lizer must be used at the midpoint(Figure 43). The stabilizer support straps must be attached MULTIPLE TERMINATIONS 1. Determine total vertical height of the fire- under tension(in shear)to structural framing place installation. This dimension is the dis- members above.When two sets of elbows are If more than one termination is located in the tance from the surface the fireplace sets on to used,the maximum combined length of chim- same chase or within the same general proxim- the point where smoke exits from the termina- ney used between elbows cannot exceed 20' 4, we suggest they should be separated in tion. (Figure 44).Example:If C,=10'then C2 cannot distance at least 24'horizontally from flue cen- exceed 10'. ter to flue center and stacked or staggered 2. Determine the number of chimney compo- vertically at least 18'apart,from the termina- nents required,except chimney sections.This If an offset exceeds 6'in length,each chimney tion of one smoke exit to the termination of would include firestop spacers,stabilizers,roof joint beyond the first 6'of offset to the return another smoke exit(Figure 38). flashing,etc. elbow,must be secured by a No.8 x 1/2'sheet metal screw located atthe underside of the joint CTD 3.The effective heights of the components are: (Figure 39). 18" i The Fireplace = 38' 1e• BC8-SS(starter) = 19' CTDT O —i—, BC8-12 = 10-1/2' Joints CTDT BC8-18 = 16-1/2' Chimney � y, 44,. 2a• BC8-36 = 34-1/2' Section 4 '144• 24• BC8-48 = 46-1/2' 4k CTD Termination = 4' IQs Figure 38 CT1 Termination = 12'to 18' 6. a No.B x 1/2'SMS CT2 Termination = 15'to 23' , This suggestion is provided in the interest of CTDT Termination = 12*to 18' better operation.If the terminations are located S4 Stabilizer = 2-1/2" too close to each other, smoke may migrate Figure 39 from one flue into the other. ' Required for every 30' of vertical chimney BC8 CHIMNEY COMPONENT and/or 10'of offset chimney. A 1/8' diameter hole must be drilled in the CALCULATIONS chimney joint using a 1/8'diameter drill.Hole 4. Determine amount of chimney height re- should be drilled in center of joint overlap The minimum installed height of the KR-38 and quired by subtracting total combined height of (Figure 40). Be sure to drill only through the all pre-selected components (fireplace and outer chimney casting. Do not puncture the KC-38 Series fireplace systems is 12'0'.The chimney components from total desired height.) inner flue. minimum installed height of the KR-43 ad KC- 43 Series fireplace systems is 16'8'.The maxi- Reference Vertical Elevation Chart and deter- mum height for both systems is 80'0'. minethe numberof chimney sections(quantity To determine the number of chimney sections and length)required. ' and chimney components required,followthese steps: Underside Of Chimney ilk NOTE:DIAGRAMS 8 ILLUSTRATIONS NOT TO SCALE Figure 40 11 Step 8. The standard Superior roof flashingBCS-CT2 assemblies include a storm collar.Slide storm Termination Maintain to collar over outer chimney,align with top sur- Airspace Combustibles face of flashing,inserttab in slot,pull tight and bend tab back over slot. Seal storm collar to outer chimney with roof caulking or mastic o around entire circumference of pipe.Also add BCB-CTD SK 2K extra roof caulking to the tab/slot area to seal Termination BC8 Chimney Above completely against water penetration (Figure Studs Root 32).Check all joints very carefullyto ensure no k water intrusion can take place. Figure 34 Figure 36 Locking Band Step 10.Usinga BC8-CTD Round Termination: Using a CT2 Chase Termination: Mastic 1. Hold CTD over top of last chimney section Refer to specific installation instructions in- (Figure 34). cluded with CT2 Chase Terminations for clear- ance and installation details. 2.Center inner slip section in inner flue pipe- slip down. Note:It is recommended that all exterior ex- posed related metal fireplace components,such 3.Center outer locking section over outer flue as terminations,flashings,storm collars and/or pipe. Push down until locking tabs are firmly flue be painted with a premium quality, high engaged. temperature, rust preventative paint designed Figure 32 4.Pull u slightly on CTDto ensure locking joint for metal. This is especially important when P g Y g j installations are made in abnormallyadverse or has firmly engaged. corrosive environments,such as near lakes, Step 9. Superior Locking Bands, Model LB, oceans or in areas with consistently high hu- may be required if the chimney extends too Note:Special galvanized over-dipped CTD Ter- midity conditions.Consult the paint manufac- high above the roof flashing.As a general rule, minationsandCTDTTerminationsareavailable turers instructions for proper preparation and if the chimney extends more than 6'above the for installations susceptible to corrosive envi- application. roof flashing,the use of locking bands is advis- ronments.ContactyourdistributororSupecior able to strengthen the chimney assembly.Align Customer Service for pricing and availability. TEN FOOT RULE SUMMARY the locking band at the chimney joint.Locking bands wrap around pipe joints equally covering Using a CTDT Chase Termination: the joints of both pipe sections. Use nut pro- vided and TIGHTEN snugly.Do not over-tighten and/or to adjacent walls and buildings is speci- g Refer to specific installation instructions in- fied by all major building codes. as this might damage chimney section(Figure cluded with the CTDT Chase Termination for 32). clearance and installation details. If the horizontal distance from the peak of the Note:If chimney extends more than 8'above roof is less then 10', the top of the chimney BCS-CT1Maintain r must be at least 2'above the peak of the roof. roof surface,guy wires are also recommended. TerminationAir Space To Use three(3)guy wires,attach to locking band Combustibles assembly,extend and secure to roof in a trian- If the horizontal distance from the chimney gular pattern(Figure 33). Guy wires are not edge to the peak of the roof is more than 10'a supplied by Superior. chimney height reference point is established on the roof surface 10' horizontally from the Above chimney edge.The top of the chimney must be Roof Ridge Roof Studs at least 2' above this reference point. In all cases,the chimney cannot be less then 3'above _LLN the roof at the edge of the chimney. O The 2'in 10'rule is necessary in the interest of Figure 35 safety but does not ensure smoke-free opera- tion.Trees,buildings,adjoining roof lines,ad- Using a CT1 Chase Termination: verse wind conditions,etc.,may require a taller chimney should the fireplace not draft properly 120* Refer to specific installation instructions in- (Figure 37). Figure 33 cluded with CT1 Chase Terminations for clear- ance and installation details. 10 NOTE:DIAGRAMS 81LLUSTRATIONS NOT TO SCALE ae BC8 chimney system is a two piece chim- Step 6. Select proper Superior roof flashing ney,which snap togetherfrom the fireplace up. based on pitch of roof. Use chart below for Start with the innerflue section with the hemmed ____- selection: end down,snap lock it in to the matching collar on top of the fireplace.At all subsequent joints, Roof Pitch Model the upper flue section fits into the preceding ._ flue section. Each piece snaps together by - Flat to 6/12 BC8-F6 means of locking tabs(9 locking tabs per joint). Check each piece by pulling up slightly from the 2'Min.Air Space top to ensure proper engagement before in- To Combustibles 6/12 to 12/12 BC8412 stalling the-next section. If the flue has been installed correctly,itwill not separate when you Figure 28 Next,slide roof flashing overextended chimney test it. Also, the inner flue joint where each section that previously has been installed above section is joined should be tight and I lat without Superior chimney sections need not be screwed the roof opening in Step 4. BC8 flashings re- gaps(Figure 26). togetherand is not required for additional rein- quire flashing spacers. Slide flashing all the forcement,except in certain offset conditions way down until the flashing base rests flat on (refer to page 11). the roof(Figure 30).Again,check the vertical position of the chimney and the 2'minimum air Step 5. The height of vertical chimney pipe space to combustibles. supported only by the fireplace must not ex- ceed 30'.Chimney heights above 30'must be supported by a Model BC8-S4 Stabilizer in- BC8 chimney stalled at 30'intervals. Flashing Spacers Note:The Model BC8-S4 adds 2-1/2'neteffec- tive height to the total chimney system. BC8 Flashing Figure 26 Install the Model BC8-S4 Stabilizer by fitting inner section down into respective section of Outer pipe section installs in just the opposite proceeding flue pipe and locking outer stabi- way;the hemmed end goes UP and each new lizer section into place over the outer chimney section goes OVER the outside of the previous pipe. Position for proper clearance through Figure 30 section installed(Figure 27). framed opening and nail straps securely(under tension in"shear")into place on framing.Use 8d nails.Attach successive lengths of chimney Note:Do not caulk or seal the ventilating open- pipe directly to stabilizer using same tech- ings. piques as described in Step 4. __ _ Step 7. Secure flashing by nailing along the perimeter into roof using 8d nails. If shingled Locking ? T roof,slide upper end and sides of roof flashing Hemmed under shingles(trim if necessary),seal the top End r ? and both sides of the flashing to the roof with roof caulking.Cover nail heads with roof caulk- - ing. BCB-94 Stabilizer Figure 27 Figure 29 Note.Assemble one component of chimney at a time(inner section first, then outer section Note:Do not apply excessive pressure to any last)before proceeding with the next complete subsequent chimney sections following the section. stabilizer when installing.Ensure each subse- quent chimney section is securely attached by Continue to assemble the chimney up through testing as noted in Step 4. framed opening.Assemble just enough to pen- etrate the roof flashing openings(Figure 28). Figure 31 Always maintain 2'minimum air space to com- bustible materialsand always check each chim- ney joint (inner and outer) to ensure proper engagement.Check vertical alignment of chim- ney so that it projects from the roof in true vertical position. NOTE:DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 9 Step 5. Fireplace should be secured to side In new construction, to determine chimney T Attic Above T J framing members using nailing flanges.Use 8d centerline,use plumb line from roof or ceiling nails(Figure 20). above fireplace to center of flue collar on fire- place. For remodeling,plumb to center of flue collar from ceiling above, drive nail through ceiling NP from below to mark position,then markand cut Firastop Spacer to passage from above ceiling (around nail) (Figure 21).Then plumb from ceiling or roof Figure 23 level directly above hole which has just been completed. CHIMNEY 300 OFFSET THROUGH FLOOR 84 Nail --'�� OR CEILING It may be necessaryto assemble the chimney at 300 when passing through the floor or ceiling area. Use the BC8-FS30 Firestop Spacer as shown in figures 24and25.Supportthe chim- ney at floor or ceiling penetration with a stabi- lizer if distance of chimney below ceiling is 10' Figure 20 or more. Maintain 2' minimum air space to Note: The nailing flange and the area directly combustibles from chimney sections. g ®® behind the nailing flange is exempt from the Attic space clearances described on the fireplace clearance label. BCB-FS30 Fireatop Spacer 2'Min. INSTALLING THE CHIMNEY SYSTEM Air Space Figure 21 Step 1. Check flue damper for proper opera- tion. When the damper is in the fully closed Step 3.Position appropriate firestop spacer at 2-Min. BC8.84 Stabilizer position,the damper control lever is pushed all ceiling and nail temporarily with two (2) 8d Air Space the way to the rear of the firebox. When the nails.Use flat Firestop Spacer,Model BC8-FS, 10, damper is in the fully open position the damper if chimney penetrates ceiling vertically.If chim- Max. 30<Firedop control lever is pulled all the way to the front of neypenetrates ceiling at30*angle(off setchim- And Attic Above the firebox. ney),use 30°Firestop Spacer,Model BC8-FS30. Figure 24 Use one nail on opposite sides to hold firestop Step 2. Using standard construction framing spacer in position.Nail permanently, using at techniques,construct opening for chimney route least two (2) more 8d nails, after chimney Room Above upthroughthe ceiling(s)and roof orthrough an sections have been assembled through the BC8-FS30 outside chase. firestop spacer and after any necessary adjust- Firestop spacer 2"Min. ments have been made.Firestop spacer must Air Space Framing must maintain adequate minimum air be secured by at least four(4)8d nails when _ space clearance at all times. completely installed. 2'Min. K11-84 Stabilizer CAUTION: ALLOW MINIMUM 2" CHIMNEY Note: If there is a room above ceiling level, Air Space AIR SPACE TO COMBUSTIBLE FRAMING MEM- firestop spacermustbe installed on the bottom �Z BERS THROUGHOUT VERTICAL OR OFFSET side of the ceiling. If an attic is above ceiling 10, 30'Fireatop CHIMNEY INSTALLATION. level,firestop spacer must be installed on top Max. And Room Above side of ceiling joist(Figures 22 and 23). A minimum 2"air space must be reserved for Figure 25 all combustible materials extending for any Room Above continuous length surrounding the chimney. Step 4.Note:Chimneysectionsare constructed with a unique locking tab design, which en- Reference figures 18 and 19 and charts Fram- O sures an immediate, tight assembly between ing Dimensions for Ceiling and Roof, which sections.Planyourchimney requirements care- specify minimum ceiling and roof dimensions. fully before assembly as chimney is difficult to 1 disassembleafterinstallation.ftsassembled, Firestop Spacer the tabs might become damaged. Be certain tabs are properly formed to ensure locking tabs Figure 22 engage properly. 8 NOTE:DIAGRAMS 8 ILLUSTRATIONS NOT TO SCALE ` FRAMING SPECIFICATIONS Framing Dimensions For kR and KC Series Fireplaces 38 43 A 40-3/4" 45-1/2" B 39" 39" AK-4 Combustion Header C 29" 33-3/4" Air is Optional *11 �le Use TOB Adapter With D 14-1/2" 16-7/8" Combustion Air KK E 71-3/4" 76-1/2" F e F 35-7/8" 38-1/4" G 21-3/8" 21-3/8" It—A—„ H* r 8" TOB-4 E. Fireplace Framing d 17" 17" Comer Installation Figure 14 K 50-3/4" 54" Figure 17 When TOB-4 is used AK-4 Combustion Air Kit TOB-4 �—C—� G Framing Dimnesions OFor Ceiling Flue Type A B —►I H No A H WA Inside Chase BC8 Vertical 14-1/2" 14-1/2" Figure 15 BC8 Offset 300 14-1/2" 25" Ceiling Framing Figure 18 AK-4 Combustion Air KK-Optional Ft—C T —:f( — O T Framing Dimensions G For Roof {F--A Pitch C D* Outside Chase 0/12 14-1/2" 14-1/2" Figure 16 6/12 14-1/2" 17" C 12/12 14-1/2" 21-1/2" o Roof framing Perpendicular to roof ridge Figure 19 NOTE:DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 7 FIREPLACE SPECIFICATIONS 30" 3- (�38.121/2-� 38:121/2- I_ 43:12 43 1s 31/2- 38.38' 43.42 3/4- 43.4242 314- 21- 341/2' 21- 341/2' 15/16- 15/16' P ®®® p 4.40 5//8x- 'I 1 �� 36.40 5/8- 43.45 3/8' Front-KR Series Front-KR Series Figure 9 Figure 10 .1a Aq n 41/2- Combus0on Air Inlet e e 38 3/4- 38 3/4- 9- On line Box i{41/2- Access 81/2- Al - 81/2" 41/2- �--211/2" 211/2"—►� Left Side Right Side Figure 11 Figure 12 4:3333 31C-� 9- I — 211/2" I 43.45 3/8- Top View Figure 13 6 NOTE:DIAGRAMS d ILLUSTRATIONS NOT TO SCALE 4 7. Assemble and attach optional glass door Step 2.Insertthe metal safety strips,packaged assembly. wfth the fireplace, beneath the fireplace as illustrated(Figures 4 and 5).The safety strips Studythe three dimensional illustration(Figure should overlap;?'for contintal coverage of the 1)to get a general idea of each element of your floor. fireplace system. Note:Safety strips are not required when fire- PRE-INSTALLATION NOTES place rests on a non-combustible surface. The fireplace may be installed directly on a r combustible floor or raised on a platform of an Metal Safety Strips appropriate height. Do not place fireplace on Maintain carpeting,vinyl or other soft floor coverings.It1/r Air$pale At tBsiaea may, however, be placed on flat wood, ply- iFigure 6 wood,particle board or other hard surfaces.Be CD sure fireplace rests on a solid continuous floor or platform with appropriate framing for sup- portand sothat no cold air can enter room from under the fireplace. ---- Hearth ion 0__—, 1/r Space 9lokikinp The fireplace may be positioned and thea the framing built around it,or the framing may be Metal Safety Strip Floor constructed and the fireplace positioned into the opening. Figure 4 Usually,no special floor support is needed for Meal Safety Strips the fireplace,however,to be certain: kA Aq k1 1. Estimate the total weight of the fireplace M/rAirSpace Figure? system and surround materials such as brick, r--- At sack stone,etc.,to be installed.Shipping weights for And Sides Step 3.Refer to fireplace drawings and speci- the fireplace and chimney may be found in the fications on pages and forframing dimensions Accessory Parts and Components List on page and details.Framing header may be positioned 18. I directly on the fireplace top spacers. I — -- Hearth 2. Measure the square footage of the floor Extension 1/2"spakx IMPORTANT: UNDER NO CIRCUMSTANCES space to be occupied bythe system,surrounds CAN THE FIREPLACE TOP SPACERS BE RE- and hearth extensions. NA MOVED OR MODIFIED,NOR MAYYOU NOTCH THE HEADER TO FIT AROUND OR BE IN- 3.Notethefloorconstruction,i.e.2x6's,2x8's Metal SatetyStrip/Platform Floor If STALLED LOWER THAN THE SPACERS. or 2 x 10's, single or double joists,type and thickness of floor boards. Figure 5 Step 4. Fireplace may be anchored to floor. Bend down four(4)anchor tabs located at the 4.Use this information and consult your local base of the fireplace and secure to the floor by building code to determine if you need addi- Note:Install the hearth extension only as illus- nailing with 8d nails(Figure 8). tional support. trated. CAUTION:DO NOT BLOCK THE HEAT-CIRCU- The safety strips should extend from front and LATING AIR INLETS AND OUTLETS ON MOD- sides of the fireplace 2'.In the event a wooden ELS KC-38 AND KC-43. DOING SO MAY RE- support is used to elevate the fireplace above Anchor Tab SULT IN A POTENTIAL FIRE HAZARD. the floor, a "Z" type safety strip should be fabricated and used to protect the front surface If you plan to raise the fireplace and hearth of the wood support as well as the floor beneath extension, build the platform assembly then the hearth extension (Figures 6 and 7). The Y position fireplace and hearth extension an top. safety strips should be tacked down to prevent L-' Secure the platform to the floor to prevent possible movement. possible shifting. Note:The Z"type safety strip is not supplied INSTALLING THE FIREPLACE by Superior. Figure 8 Step 1.Slide the fireplace into prepared fram- ing or position fireplace in its final position and frame later. NOTE:DIAGRAMS 81LLUSTRATIONS NOT TO SCALE 5 r Insulate Joists CHIMNEY HEIGHT Same As Ceiling The total height of your KR or KC fireplace system from the surface the fireplace rests on to the chimney top must not exceed 80' andI ; Heats mustalso meet minimum height requirements. Draft stops Refer to the minimum system height chart. Mennen I Minimum System Height ;Hearth BCB FirestopI i 0 KR/KC Series(BCS Pipe) Optional BCS-CTOT Outside Chase Termination 38° 43" Non- Combustible 9 Vertical 12'0' 16'8' Figure 3 Chase Installation Flashing Must Be Carefully consider the position of the fireplace CoverTo One 12'0' 16'8' opening with respectto the location of adjacent Chase Offset or nearby stairwells, bath or kitchen exhaust Opening fans and/or return air registers for forced air Two 25'0' 25'0' fumaces/air conditioners that could cause a Optional Insulationsmokingfireplace condition if the house is In ls off° tightly insulated. Chase CHASE ENCLOSURE If there is a continuous perpendicular side wall closer than 15'(18'on 43'models)from the A chase is a vertical box-like structure con- nearest side of any 38' fireplace opening, it S. structedto surround thefireplace and chimney. must be protected with a wall shield.Use a 40' Level Solid Refer to Figure 2 for a typical chase configura- x40'x1/2'wall shield constructed ofmillboard Continuous tion. As with all chimney installations, avoid or a durable non-combustible material with Surface overhead obstructions such as trees, power equal or greater insulating value than K = lines,etc.A chase should be constructed and .84BTU-IN/FT2HR-°F(see page 16).A continu- insulated just like any outside wall. In a cold ous perpendicular side wall cannot be closer Insulation Outside climate,we recommend the base of the chase (Thermal Barrier) Bate than 8'from the fireplace opening under any should also be insulated between the solid circumstances,even if protected. continuous floor beneath the fireplace and the Figure 2 chase bottom. Chase insulation in a cold cli- ASSEMBLY STEPS mate installation is not required for safety. WARNING:IF INSULATION IS USED,THE ASSEMBLY OUTLINE Note:The following steps representthe normal FIREPLACE MUST NOT BE PLACED DI- Before You Start sequence of installation. Each installation is unique,however,and might require a different RECTLY AGAINST IT. INSULATION OR sequence. VAPOR BARRIERS,IF USED,MUST FIRST Checkyour inventory listto be sure you have all BE COVERED WITH GYPSUM BOARD, the necessary parts supplied in good usable 1. Position firebox prior to framing or into PLYWOOD,PARTICLEBOARD OR OTHER condition.Check also for any concealed dam- prepared framing. MATERIAL TO ASSURE INSULATION AND age. VAPOR BARRIERS REMAIN IN PLACE. 2. Install the chimney system. Check the operation of the damper. The flue damper handle extends down from the inside 3. Install optional outside combustion air kit. WARNING: DO NOT PACK OR FILL RE- top of the fireplace;push into close,pull out to QUIRED AIR SPACES WITH INSULATION open-takes firm pressure to lock closed. 4. Field wire main power supply to the KC-38 OR OTHER MATERIAL.NO MATERIAL IS and KC-43 for the fan kit and install the Model ALLOWED IN THESE AREAS. LOCATION OF FIREPLACE CF-ADK Adapter Kit. (Electrical connections should only be performed by an experienced, Carefully select the proper location for heat licensed/certified tradesman.) Note: Do not insulate the chase cavity with circulation, aesthetics, chimney obstructions blown or fill type insulation materials. and clearance to side wall(s).With proper pre- 5.Plumb gas line if a decorative gas appliance planning,a slight adjustment of a few inches will be used.(Gas connections should only be Note:Localcodes maynotrequire firestopping can save considerable time and expense later performed by an experienced, licensed/certi- at the ceiling levels for outside chase installa- during construction and assembly. tied tradesman.) tions. However, it is recommended for safety and the reduction of heat loss. 6.Complete finish wall material,surround and hearth extension to your individual taste. 4 NOTE:DIAGRAMS 8 ILLUSTRATIONS NOT TO SCALE V PRECAUTIONS The KR Series is a conventional radiant heat WARNING: FAILURE TO USE PARTS fireplace with a standard bar grate, optional MANUFACTURED BY SUPERIOR FIRE- Note:These fireplace systems are not difficult outside combu ion air kits and optional deco- PLACE COMPANY FIRE- to install.However,in the interest of safety,it is rativeglass i 9s. ,VARIATIONS IN TECH- recommended that the installer be a qualified NIQUES AND CONSTRUCTION MATERI- or certified "tradesman" familiar with com- Note: Illustrations shown reflect "typical"in- ALS OR PRACTICES DESCRIBED IN THIS monlyacceptedfireplaceinstallationandsafety stallations with nominal dimensions and are for MANUAL MAY CREATE A FIRE HAZARD techniques as well as prevailing local codes. design and framing reference only.Actual in- AND VOID SUPERIOR'S LIMITED WAR- stallations may vary due to individual design RANTY The most important areas of concern dealing preferences. However, always maintain mini- with the installation of factory-built fireplaces mum clearances to combustible materials and The KR and KC systems consist of five basic are clearances to combustible materials,proper do not violate any specific installation require- 'sub-systems": assembly of component parts, height of the ments. chimney system,the properuse of accessories 1.The Fireplace supplied by Superior and the techniques em- The KR and KC Series fireplaces have been 2,The Chimney and Termination ployed in using finishing materials applied to tested and listed by Underwriters Laboratories, 3.The Optional Glass Doors the wall surrounding the fireplace,hearth ex- Inc.(Report No.MH8988)to U.L.127 standard 4.The Optional Forced Air Kits(KC Series only) tensions and wall shields.Each of these topics for U.S.installations.These units are intended 5,The Optional Combustion Air Kits will be covered in thorough detail throughout for installation in residential homes and build- this manual. Please give each your special ings of conventional construction,not in mobile CLEARANCES AND HEIGHT attention as you progress with your installa- homes. tion. REQUIREMENTS These fireplace systems are designed for instal- INTRODUCTION lation in accordance with the National Fire Pro- The fireplace maybe placed on or near normal General Information tection Standard for chimneys,fireplaces and construction materials*. The combustion air solid fuel burning appliances;NFPA 211 and in kit,firestop spacer and roofflashing(not chase accordance with codes such as the flashings)may beplaced directiyonoragainst The KC Series are wood burning appliances normal construction materials.'The chimney featuring a self contained heat-circulating sys- National Codes,the Standard Mechanical Code g and the Uniform Building Codes. requires a minimum 2'air space to combus- properly position the fire.Outside combustion tem.Astandard bar grate is also included to tibles.A combustible mantle may be installed 12'above the opening of the fireplace as per air kits,decorative glass doors,forced air kits, NFPA 211,Section 7-3.3.3. and the fan adapter kit are available as optional equipment. The fireplace and chimney system must be enclosed when installed in or passing through TYPICAL INSTALLATION a living area where combustibles or people may come in contact with it. This is important to prevent possible personal injury orfire hazard. Q., _ For questions, please call your distributor or Superior Fireplace Company. Special restric- Forced Air Kit tions apply to the front and facing of the fire- (Optional) place and nearby walls(See pages 16,17 and 18). Chimney And CHIMNEY SYSTEM Termination Superior manufactured fireplace Models KR- 38,KR-43,KC-38 and KC-43 are designed and code listed for use with Superior's BC8 Thru- Flow chimney System.Use Superior's BC8-SS Starter Section on the KR-43 and KC-43 in order to adapt to the BC8 chimney.Always use Superior's Thru-Flow chimney components with Outside:tion Outside these fireplaces. Do not modify or alter these Air Kit Air Kit f opitonai (Optiomt) components as this may cause a potential ®_a serious hazard and void the Superior Warranty. ® 'Construction Materials: wo KC Series KR Series •framing materials •paneling •particle board •flooring •millboard •dry wall Figure 1 NOTE:DIAGRAMS&ILLUSTRATIONS NOT TO SCALE •plywood •etc. 3 TABLE OF CONTENTS IMPORTANT: PLEASE READ AND 12.Always ensure an that adequate supply of UNDERSTAND THESE RULES TO replacement combustion air from the outside Safety rules..................................... page 2 of the house is accessible to the fire to support Tools and building supplies............. page 2 FOLLOW FOR SAFETY. normal combustion.Fireplaces consume large volumes of air during the normal combustion Precautions ..................................... page 3 1. Before starting your fireplace installation, process.In the event the home is tightly sealed Introduction..................................... page 3 read these installation instructions carefully to with modem energy eff icientfeatures,Superior's Clearances/height requirements...... page 4 be sure you understand them completelyand in optional combustion air kit may not provide all Chimney system.......................:...... page 4 entirety. Failure to follow them could cause a the air required to support combustion.Supe- fireplace malfunction resulting in serious injury rior is not responsible for any smoking or Assembly outline............................. page 4 and/or property damage. related problems that may result from the lack Location of fireplace........................ page 5 of adequate combustion air.It is the responsi- Assembly steps ............................... page 5 2.Always check your local building codes.The bility of the builder/contractor to ensure that Pre-installation notes....................... page 5 installation must comply with all local,regional, adequate combustion air has been provided for Installing the fireplace ..................... page 5 state and national codes and regulations. the fireplace. Installing the chimney system......... page 6 3.Superior Models KR-38,KR-43,KC-38 and 13.DO NOT use a fireplace insert or any other Fireplace specifications................... page 7 KC-43 must be installed with the Model BC8(8' products not specified herein by Superior for Framing specifications.................... page 8 inside diameter) Thru-Flow Chimney System use with this fireplace.All gas log sets must be 300 offset floor/ceiling through only. These systems are intended for use as operated with the damper clamped open, in- residential type appliances.The chimney sys- cluding"vent free"log sets. Ten foot rule summary.................... page 11 tem must always vent to the outside of the Multiple terminations....................... page 11 building. 14.Superior Fireplace Company does not war- Vertical elevation chart.................... page 12 ranty "smoke free" operation nor are we re- 4. To ensure a safe fireplace system and to sponsible for inadequate system draft caused Offset elevation chart...................... page 13 prevent the build-up of soot and creosote, by mechanical systems,general construction Chimney component calculations.... page 14 inspect and clean the fireplace and chimney conditions, inadequate chimney heights, ad- Special offset instructions............... page 14 prior to use and periodically during the heating verse wind conditions and/or unusual environ- Offset calculations........................... page 14 season. mental factors or conditions beyond our con- Installing offsets.............................. page 14 5.Use solid fuel only.DO NOT use artificial wax trol. Optional equipment......................... page 15 base logs,chemical chimney cleaners orflame 15. Never,under any circumstances,install a Glass doors .....................................page 15 colorants in your fireplace. fireplace,chimney component or any accesso- Combustion air kit........................... page 15 ries,supplied by Superior Fireplace Company, 6. DO NOT use charcoal or coal under any that has visible or suspected physical damage Forced air kit.................................... page 16 circumstances. as a result of handling or transportation.These Gas line connection .........................page 16 items should be inspected by a Superior dis- Cold climate insulation ....................page 16 7. NEVER use gasoline,gasoline-type lantern tributor or qualified factory representative to Fireplace finishes............................. page 16 fuel,kerosene,charcoal lighterfluid,or similar ensure safe condition.When in doubt,consult liquids to start or "freshen up" a fire in this your Superior distributor. Mantels and trim .............................page 16 fireplace. Keep any flammable liquids a safe Hearth extensions/wall shields ........page 17 distance from the fireplace. TOOLS AND BUILDING SUPPLIES Accessories/components list........... page 18 NORMALLY REQUIRED 8.NEVER leave children unattended when there is afire burning in the fireplace. Tools should Include: Phillips screwdriver 9.Always keep flue damper open when heat is Hammer present in the fireplace. Saw and/or sabersaw Level 10.Before servicing,allowthe fireplace to cool. Measuring tape Always shut off any electricity or gas to the Plumb line fireplace while working on it.This will prevent Electric drill and bits any possible electrical shock or burns. Pliers 11. This fireplace is not intended to heat an Square entire home or be used as a primary heat Building supplies: source. It is designed to ensure homeowner Framing materials comfort by providing supplemental heat to the Wall finishing materials room. Caulking materials(non-combustible) Fireplace surround and hearth extension materials(non-combustible) 2 NOTE:DIAGRAMS 8 ILLUSTRATIONS NOT TO SCALE a INSTALLATION INSTRUCTIONS Installation This installation manual will enable you to ob- tain a safe,efficient and dependable installation Instructions of your fireplace system.Please read and un- derstand these instructions before beginning your installation. For Superior's Do not alter or modify the fireplace or its KR and KC components under any circumstances. Any modification or alteration of the fireplace sys- Series tem,including but not limited to the fireplace, Fireplace chimney components and accessories, may void the warranty,listings and approvals of this mode/S system and could result in an unsafe and poten- KR-38 tially dangerous installation. KR-43 IMPORTANT! TO ASSURE PROPER ALIGN- MENTF GLASS DOORS:INSTALL THIS FIRE- KC-38 PLACE IN A SQUARE AND PLUMB CONO1- And TION,USING SHIMS AS NECESSARYAT SIDES KC-43 AND/OR BOTTOM. PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE. KR Series Us L KC Series FILE NUMBER: MH8988 08/25/1998 14:15 516-473-1584 CONSTRUCTION OFFICE PAGE 02 AUG-2s—,Pe TUE 1 1 Sep3 In today's l,orttc budding environment, cost Is always an true.That's tba t}finking behind Suptioes tmfdcls K"M and KR 49. the KR offers born"wnen their most desired homy amenity-the warmth and dwom of a bouad MepbA--at the lowest possible cost. The Clean btx*et�t�lestttrly no weed SKIM 9rmwnd MAMASCOO = can be insbMed right up to the front openinlL +ring the look of a # cm�attto w n%wmgy drepac+t!. 'Me KR 389 has a 30• scr+eezi amikv,while the KRA featuv"a 49" t ttcrea:o opening."use a space soft M chiumey tlyfltem.OP►oS3#A"wn include sort otttAle c rnbuit1w air kit and a cbnim of dr,�nro m boon in a vasiety of faks and An}abes. f Front f 1 { Vkw I �� •Outside CombuWon Air Kkswim c9aw. T�01,--14 W Caaalk�M•.�[�+�'�--' — � � !•Sled`� � I i •� .a. fz . i8 Len Side 43 Lit AR.plgl flC�tTJ tj. �4/� yi `%IT Intl (fes s rs �y'i'fM. ( ..'' DfYw>14cAo+ ,IaISIN `.1.'��. +,►sr� tXS.RE.i1. ttwne on tdltM IF 11.1ri.wf. � I � �+trxAb exterior '�' a_ �k1LauoaMe I I i ( ( I I ! 6c caaahalir+a rw _ stinirfaao r 1}*,• I I I a�rafdaAfdbn. x 1 _ tipJAL ViCW .r�. 04` �J I a..►> rT� W 0aerIbY4Rdr! }I'a0f7tl t�M i l ( i l vcwtii. e. 1 Re b, I I t {_ CM*UCUM rrtreraKnr I - i I arfcfiors so A yrterior. ., r {r I, >+/ treaiat*to boor. Samd,ad NO mate. Fol — trim dee keu rnnrNy olarr,»k+a . 9".70 y...4i 9►ktU •ih I UFI �iYtf k�rlh�fc °YM"' ptlaalMoa- flafbedf.ides r: Ku. X03,+• 'V if."� Stirutacd oN+nt dd oo.aia 1101 fi ar"kit LladY70�D. y0r :t�f lK/1llrtfllYl�q+rQ�uak�WrMNitl�ttr.g4 ��au,r;fnd br uw d fw**eef�rpaw .corn*�iMp f� 1vtdi 0 dpRis .mal rl^digfrnrdtaw n y�,, PK">;*d to dw r or d4ceWru im%tNm pMk� hr 4W W MIMUTA"is34 Mandud.dplxmcd by UL yr{.rta itittrb111�1 andwtR r�ortra�ntela) -6�L�M 0 Conwir rav 0ir6'1aAar for te(�el�r cvd. m. r�i 4-1AAr A Fe.,F1+Af1rl- ,CA> ]'Noted in II.S.A 019*by 9upMw Eltedaoc Company Plants is Fu?W tl.CA:T.Th t 414,'�N.ENt 19M riat9=1ZREV n vas rtlrs,�rter+•e.ee�.■rolt..,f...:.a.a..s,.rt aw,.np..e.,.r�weba�,fa� ao+wa nsi++� r ' I • t ! t GAS LINE CON'NEC'TION./ COLO CLIMATE INSULATION • � --PlctsArd = i Install only a 'A'black iron pipe tt+,ro#'Lfgh fire If you lire in a cc; c; ;r,;tN it s e teciatly max.— Wary place wall for connectlon to a deoortitive gas importar;t 1, > r,,l ,;iacr ,- apptiance insldethe firebox, outside the iron opening with non-on bust,t)e and pipe connects to+a gas shut-off valve}ecessed wherever cold air cou'd enter the room Sur, , �_— lush into the Wats or floor.The valve 9houid be rourrding materials must be caulked where it Combu�rihra Controlled by a removable valve key ttr safety maets the biack meta!faCiq Of the fireplace to and Tilm !1 avoid cold air intrusion Use noncombustible T liCnG•?rDustihl0 Always plumb gas line installa%ner local caulking material only on fireplace facing to frlfe. f WaII Ca sting Codes. Check 011'COMQCtions with s v suds; seal Alsa,the outside air inlet duct should b» ---oo tint 810rlt •r Seal Top leaks calif bubble.(Never test any gastrie GPn- twrc;ped with noncombustible in5ulatir}n to and earur ve+lts hection with a match or Open flame. t minimlz!, the formation of condensation- Oz Prrept�rtr , ` not place Insi,laton rrateri115 on top of fire- This provision is`intended only for connection place or agatnSt chimney se,,- �s r 1c9tt tnstarra;ren ; to a decorative 0",appliance incoepcihliitg an Al?Scries Vo-r') SIA017latic Shut-Off device and complying with Super or strongly recommends that the the Standard for DeCOQVve Cas Applf rices for CF-AOK adrlptar kit be purchased and installed figure 49 ; insta+fativn in vehlad fireplaces,ANS Z21 ZO. on the<;-K-2 fires>iace T nis will','PIP Prevent Instal!in accordahce with the Natiorial Fuel Gas outside inttusicn air from enter in­ y.�ur hemi; Code, ANSI Z223.1. This Complies with the through Ahe firef•l .e. Hearth Ulenslon$ end Wall Shield& revised U L. 127`startdard. i Note:A"air space must be preser,f�r�r ar! A hearih eutensloo must be inSfa7'i with CAUTION;PLUM NOGONNECTIONSSHOULD corr6usr^'e m,,!rr;:?;;s ,rt2nd:^p 1r)ranyCon- all tireplaces. It is to protect the c.mDusf+bre ONLY RE PERFORMED BY A QUALIIED, LI hnucus leryfr a',}:arF•�t tc t,e c i^tr,;y, floor in front of the fireplace from butts iadiar.t R CENS€D PLUMB1113.MAIN GAS SUPPtYMUST heat Ind sparks. The `,earth extensior must BE OFF WHEN PLUMBING GAS LINE tf 0 FIRE It is a,pe sally mp,+tar?t !c iruiate hetv,er,i e>nerid 8' beyond both sides of the fireplace PLACE OR PERFORMING SERVICE. the gaud$of an 00514e crab=:a':"y and under opening and 14 beyond the trOns Use a`tr.arttt the floor if the floor is abc,ve grol,ntl level Co e..zl.rVon constructed of 3 dur,ble nbncom• If you're lnstallin a gas line,connect�;t bbfr re n:,t pfa, inst,Iatitm darer-tiy against the Ere tu�tibie mater;al staving an equal or greater t the fireplace is lrarrmed and encloopd in the place Of chiretn?y 5y ler i, insulating 0'ue Of k 2.84BTU IN,FT'HR°F or a finished wall. Th�gas kMOckOut is delormined thermal resi$tance that equals cr Eyceros r by S 1 !V round Indentation laca`ed at the FIREPLACE FINISHES 1 iS }fA IF FTr;'BrU IN. A rr;pirrurn v: think bon.JMand sllghllyoff cenierin the siilie refrac• narrr_trnDt,Strali?material Is 31 tt!af:S rr;,jlred for-ses THE KNOCKOUT ISALWAYS RFMOVED Mantels and Trim over a noncombustible or slab floor FROM INSIDE THE FIREPLACE. DD NOT AE- it .5 S,clef . es butt t MOVE THE KNO KOUT UNLESS YOdARE IN „ m your fi;ep,iacF Note:Any np,app,n�u�tible.mate s a :rr it i5 po5NOr-ed a-d the chimneyis in- e � TALLIFiGAGA UNE.rfrEm,Ov11isaftempted ,t. r kv:r!ieislessMarr.84orwhose,,v3'ua:;,ncre stalled Farre raC1G.u•e for chimney artd fire th')9 1 10 is acceptable fromtheouterwrapper,5idereiractoc�darr�+aae place with 2 x 4 s (r,r heay.r.r} lu�r,5rrr, may orcur, With a medium-sized hammer, lightly tap the stfrface of t1ne inCentalion. Tr,e if ih? fireplace Is installed on a cnrrt:,sfible fefractory material is very thin fit this+area 8n0 Nefe TlrB heudFr m��yrast 017!t,e Luc(Z,+,r^eta! boor use the metaf safety strips!,provided}on tCP ST,2C6r5 o,=t trip of the r,rut k",rhe header r Is easily removed. Once a small hole has been tha floor eic,?nding half under tt.e!fireplace and trade,continue tfpping until you havi reached mus;rat be notc,red to!it arounri fir, ,,;gars. hall�,nderir,Q hearth BxteMslon(rete:tc rrgu,eJ SuMicientdiarn�eldrforthegaslinetofhthrourh. The KR 2 and Ki'-2 firep;!.ces may sji dlrectty 4af7a5 The enti }. re knockout does not have to be re Gr, a corftbut'tib;e ;urfE,.e, A 2' air spare +s r mav;d.Remove fn5ulatiOn in the gas line than. + (�l;red t,etw4en rr,mbus'ibie frac ;ng and the A "pi shield r is required ware 0 r,:)nt,nur,`t, net. charney Cnmhustibte rn;Intel; and trim n;a tre'p..rdlc Ila, Side wall !S w thin t S' r f t.te y fireplace opening 0 the KRXC•38.2�modeis. to insWied 12'above the.firr;)II re open„ria as Use a 4O'x 40'x', 'wall shield con:lf _ i IMPOATAHT:REPaC!(INSULATft7NlVigTER1AL urteu of IN SQUAf�E HOLE AROUND GAS llt�f INTE. per%rFA 21 f Sar.lion 7.3 3 3 ,.'':d ligate ” ~= mi"hoar,;or a durable,nonCombustibte-rate- (fama^t itso,do,!nconl�tiSli�l�rnaIerl31.iti:; Iht(1RAFldf;YTEI�iOAbCCrAInt�►CL,fOSEAI. m from tr'ese re +:inert r..5. f- ria!hat'inp an Aqual er praatAr tnG:statIna Ua+..o e`r•' p` q ,e ' as as it than K= .BaBTU ;W T?HR IF, CAUTION: WI�f USING THE DEC lFtATlI/f d`='esncitirterfarew''t;hes-sta!laticnoropera• GAS APPLIANCE, THE FIREPLACE DAMPER t r'rt c't at':ss doors or bf^fir. the inlets ilrt?I If t replace is installed diagonally 3;:r t o cutlets ort lVlodr'K�, 38-2 9 y os a SO MUSTOE SET INUE FULLY OPENPdSITION, Cornet; no wall shieid tire reqt,lr� i 4 1& H{ ..r:?UF..•:Z.i..i;y'P:Ti;N$4(;T�Q S�XE r 16 � Rj F E F , � 7 .._.,.— -�._.�`�`w Met1,�CsafDe,e;mir'n�keartnEre�stan Arlert,3!i:tFfea'thEr�•1st�n ' and Watt Sn;elaf Ega1r'aienls acrd Wali SPOe'd M,'.d•itls le t rr�r l�' To dlr, ^f' :;= ! c�-:�� r:� 'tC ' a ry tfc!td Val7ei M:r 1P;'k1 r'z!r'-at w'en a thrr Va�,ls apt knc*- f,". ler'a1 tr 1, . ' 1 Tri:�r f e o ;r.'�s Mt,IboerQ � es t,1f K r1'„C C'�� .rP�r*,2!a,a Af!�r�ta'!,e �>I'.Bf A? ,ot of d'-sited malefiai Ma+f a! S.� ` atm Exama'e :+;ire Cv23{!;s;c be u.e, , ,�.tie Ommor b, CA i 11�` t�C•34 t a;r��e H��u rh,{k-i�st i!,S ,,rE.r:a' C "'e'it R101dr 500 0?C 3' flp�ri Sd Using t`:� i�.f','s C Arnie 1111 • - � Daa�re. b i?'�t �`Cr,:'t, �;r� i^;Ck'r,� of..S, 043 Pf:ulreQ s T;i'.� .a• Vie,�•-� ,, eft CV2:10 0 43 2 3: _ T1+c+':r�.s ac r3r.e i l,s,t. Mace :r tU.3 cy, Sm} trate-'a';;e'i%hN M126 0 rT 3 70 T1, x T� '�:��� -,•_. 1 _ �a` -1 Tf(;r�i.5�. � oA3• x ��� .. � ���i.1:�4 �'°drt� e+';wi1;� ,;�►f e;'" r`: +cA 18.2e. *„ !:rr;; '*,�• ` 4• - - _ - - - - - - - - • - ' ; A�Sa: .�''jlk 051x '.1-025: '.' "A' srxTsi .ixvoo.;y f r Nutt 31 r', 11,1'S des'A tG at'r +a .r.ary:e*ea'',tr'r' Ria^ to a It-'el of S. C� r,ert a''vt "�, 'c.r oCS:rLw r ve'„a.'os,' . M^ it f kre:s Su r'1 t 11''d�Crdrt','-dt'J'�0��G�CP`r;-Ct•. Mese* fee•,Skn ~• ^ S rratr .!5 N A bt .•s?�'u 0� s• i c• R.3+'rtu : r�,c a' ;r: •� r •!_,.�s^ � Tt i�F.�f3. f Y2 it ?Jr5 edi (l',' is ✓r:� SC "fir 'c1 'i d1Re^S 9r 'S 0 c �e,i`'t '� '� :re cc37 T i r'cti4s1 t 19 x T, brr•:R r 6 a' RarXTr•ati� x3 'S'• Ir} 46V lit ?33' - fi,G .3! 'S too-JldiCjdS lt!It*; An$:1 e .S"G r c .051 x li s 0� • f�;� ,.R �afllTr:02�x '�' � 1r v lure; ,; -+���*e'1:;L L-.C+• h':! r,a• A fiOr1 Ot mi:a'ia S 3't ;�j1a;'e fo' use 4S �', -'Ole Stagy Se' 'f1 'n' r y ThQ"� r2ti,ES•i'f uSeQ to '"=k,..�.1pr��9"d t ir:d 7� 0 d'D ; Tc; dellrk ^!otit;tt"•li�:r-E'�dS'�.,;tS Gf r+ytDrl. �aSt4id;,4`'Rva"As"art add:1114,khtrtr a•? Rr; 'xTO C49 x1•'1 a k rlr�h are 'G! A „ f x,T.• 0 20 x '.i' s } "R vara°.'' t'4 The -urn all R jai.es":S k dSscftT,d�C`i�ruS ,FID• !� + O$ • 1J _ V,8 TM S w_1'tl to •r V t�;!a"r rf�,a!4''d'fp ►np."'�ar"i Qx.'ir►S�.'S -.:1 I� ! '+' e � •VIra4 ta�en fsuT r�dr � c"'•ecu, � .90uc' :ra;• +•o'c .'o . a c�. •j t�EQs '�'e rE.;;lr2�"R �3-�t-C; 5�.� •'m•n 'yam tf�t{Ene±s per 11$1('q i sE7e D^;4V3 4 a ., NOTES: Young & Young, Land Surveyors 10 SANITARY DETAIL 1. SUBDIVISION MAP FILED IN THE OFFICE 400 Ostrander Avenue, Riverhead, New York 11901OF $s SEWAGE DISPOSAL SYSTEM - 2 POOL AUG.H21 CLERK1987 AS FILE NO.OLK COUNTY ON 9 '� 516-727-2303 Xaa< IILtItg HOUSE N.T.S. O 6t,3g 2. ELEVATIONS SHOWN HEREON ARE FROM O 5yW;5 ACTUAL SURVEY AND ARE REFERENCE FF=18.01 TO N.G.V.D. (M.S.L. 1929). < Alden W. Young, P.E & L.S. (1908-1994) FINISHED GRADE x W IIlIlt� 153 151 I Howard W. Young, Land Surveyor M.i 14.4 3. THIS PARCEL IS LOCATED IN FIRM ZONE /� Thomas C. Wolpert, Professional Engineer A4 BASE ELEVATION 8.0 AS INDICATED ON Kenneth F. Abruzzo, Land Surveyor O FLOOD INSURANCE RATE MAP PANEL NUMBERED John Schnurr, Land Surveyor #tanning IE=13.3 IE=13. IE=12.6 IE=12.4 00 �s � 360813 0116D LAST DATED AUG. 16, .1993. n b �' a 1000 GAL 6' O rc y . £ngiussring SEPTIC TANK cEssPooL 4. ■ = MONUMENT-FOUND h �� GROUND WATER = 1.4 3' MIN. 5' 5. = STAKE FOUND SUFFOLK COUNTY DUARIVIMT OF HBALTH SUVM a R6 g g $"n`l "` - 6. • = LATH SETS_ PBPj=P=APPI MA.L OF PM A j a SWGU FAMILY RBSMNUiCa Q1ftY i Lot 8 O DATEA-20 �, ti;;AW. NO "-[ IlD (Vacant) _ \ ) 2<3;� I i h \a N APPROVED 1 IIV � 0 FOR MAXIMUM OF HBtStOO'MS a W° EXPIRES THREE Yrms FROM DATE OF APPROVAL 110 So- ro I pyo Q• 00. , :� ¢-' C SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES CERTIFICATION aB=W (T I 1Q \ \ Lot 9 CU "I AM FAMILIAR WITH THE STANDARDS FOR APPROVAL AND CONSTRUCTION OF SUBSURFACE fir-- 0 " SEWAGE DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES AND WILL ABIDE BY THE CONDITIONS of I Area \_ 47777 S. SET FORTH THEREIN AND ON THE PERMIT TO CONSTRUCT." 8'15'10" E 1,36.79' �:�6 \ , �Fi,e oQ �gZF 8I4.20 \\\ \ \ �-� 8 !� r U g APPLICANT'S SIGNATURE:., t _lt BLUFFS CGIsISTal CTION CORPORATION "N �1 $ANITARYD�\ �' ' APPLICANT: P. O, BOX 5240 1o.su Y$t4.6 25 �T SYSTEM \ O IrY F: .:�.' ^Y ti l } Miller Place view York 1 i 76 4 2.1Y • y j-Lp Cl)�. STREET ADDRESS: M , W •� (�20� o \ � _� 5 'a�= �S. 1 i N �' a* CITY: STATE: ZIP CODE: � Wt 7TOO v JIo �m.ogmm a n o x \ ' ai r •,~.. CA' C., TELEPHONE 3 TELEPHONE NUMBER:0' Soo a`g5<`BP.W 1 Offi4o �9.33 S61.0• �\ O 0t ff1142• w =.- - N :PROPOSED SURVEY FOR $ �� -Z r �z WA\\R SERVICE =, KRISTIN YOUNG 2169' J �,.,, i W �a o� I I 99 3' t`-- I LOT NO. 9 "HARBOR VIEW AT MATTITUCK" is a rn �m Ol_ __- I O ti�O• wol 1 p� 0 N to \ O�, M I ,�I N PROPOSED DRVEWAY At: MATTITUCK Town of: SOUTHOLD = I 001 ► --� Suffolk County, New York, Z i I I \ TEST HOLE =oda 01 o EL=6.9 7 EL=12.4 I E =14. X r M9 01 FROM FILED MAP "gi< ^ I n 1000 115 17 17.9 Y- S 88.15'10' W 278.96 1 Suff. Co. Tox Mop: I ANO EL=12.5 0' District Section Block Lot lgai ` TOPSOIL i'-c m I AND LOAM N vmr*r I I I 50' �O z W � �z N OZ; I I O N Gam% ,p z N o I SAND �l 10 D r I 12' DRAINAGE EASEMENT ff<�5 >7� to jLn I Lot 10 GROUND WATER Amo i I (Vacant) I I EL=1,4 - jN= Z M�1 o Z O WATER IN W 2"� y ! o SAND DATE : MAY 1, 1997 0 � S& Z o> SCALE :1" = 50' a JOB NO. :97 - 0297 '<a 15.0' SHEETNO. OF 1 �3�W O � ;• O S= "Y0970297.DWG" 0 0 NOTES: a�FW Young & Young, Land Surveyors BA 1. SUBDIVISION MAP FILED IN THE OFFICE �� 400 Ostrander Avenue, Riverhead, New York 11901srr OF THE CLERK OF SUFFOLK COUNTY ON :382. IIIITTt� AUG. 21, 1987 AS FILE NO. 8377. �O 516-727-2303 .?1 2. ELEVATIONS SHOWN HEREON ARE FROM 0� 0�1`< ACTUAL SURVEY AND ARE REFERENCE TO N.G.V,D. (M.S.L. 1929). < Alden W. Young, P.E & L.S. (1908-1994) 3. THIS PARCEL IS LOCATED IN FIRM ZONE �j� Howard W. Young, Land Surveyor_ `/ Thomas C. Wolpert, Professional Engineer A4 BASE ELEVATION 8.0 AS INDICATED ON Kenneth F. Abruzzo, Land Surveyor 0 FLOOD INSURANCE RATE MAP PANEL NUMBERED �lauaiuq ( / � b John Schnurr, Land Surveyor 360813 0116D LAST DATED AUG, 16, 1993. �°�° o a50� 4. ■ = MONUMENT FOUND 0 Fo �nrnrgiag 0 5. STAKE FOUND rV7-ni � 3zN, 6. • = LATH SET jig;m .R =W�0 �. � , Lot 8 � F a �Z C) J � 0 i FIRM ZONE �� Z� 4' BOUNDARY UNE / F- 03 Z o \\ � •pA � S 6�•4 � ry�rV• ' \ FIRM ZONE �^�Pc�1 �'O 4'SOa �Z N \\ BOUNDARY LINE ,. 1 �.� O / �j 6 0' J oo� I \ PLACE HAYBALES OR N '�OO• Lot 9 \ SILT FENCE DURING �! \1 CONSTRUCTION �� — ` F`Rii \ Area 47777 S.f. P.Roz z `\� §8'15'10" E 136.79, \� — O�- G<zo .59� 84.20 _,--'� I '• \ h U"- " CID ION 5t't Z I 7.r w W 1. . �'• �' I 11 mss• y ,. r =a<I 7t r� oy 1: ti 0 N W WaW ' �.� �• \ py c o<ais Q Sc�O• 'Lb\� I . z .018 D N U o W' B G �. I �� \ 9.4 _—_--67 z 8 -- zwow 0 –�– � �¢ � SURVEY FOR: 09 ?J y N V) ; "i JAMES F. DONOHUE �� HoNQ&� g 00 0 0_.1' 0 g LOT N0. 9 „HARBOR VIEW AT MATTITUCK ti� w i 0 rn oZ 1 �0 0D �, At: MATTITUCK Town of: SOUTHOLD o I Xm \: N =� �1.o ;� o Suffolk County, New York �g O W o �o f•--- - 1 s Z 90. 3' 163.73-10 1125.00' n S 88.15'10"'\ W 278.96 Suff. Co. Tax Map: 1000 115 17 17.9 1' \ District Section Block Lot ��y> I I CERTIFIED TO: g a JAMES F. DQNOHUE , 1997 gym NOV.. r I I SUFFOLK COUNTY NATIONAL BANK W I F OCT, 15, 1997 FIDELITY NATIONAL TITLE INSURANCE COMPANY o OCT. 2, 1997 Vg � v I I Lot Q 12' DRAINAGE EASEMENT JULY 31, 1997 0< JUNE 26, 1997 o"">-m0 0(A ol: JUNE 18, 1997 R.>C: � ' � JUNE 9, 1997 P-9.25 o _ DATE : JUNE 2, 1997 84„< N� N Z r -n SCALE :1” = 50' .0 0 oia JOB NO. :97 - 0297 ;aF>' Z rn> SHEET NO. :1 OF 1 Z. O S "D0970297.DWG' 0 0 NOTES: Young & Young, Land Surveyorso SANITARY DETAIL 1. SUBDIVISION MAP FILED IN THE OFFICE 400 Ostrander Avenue, Riverhead, New York 11901 N�s� OF THE CLERK OF SUFFOLK COUNTY ON D1I11<JSEWAGE DISPOSAL SYSTEM - 2 POOL AUG. 21, 1987 AS FILE NO. 8377. 516-727-2303 HOUSE N.T.S. O oBog 2. ELEVATIONS SHOWN HEREON ARE FROM o•0� ACTUAL SURVEY AND ARE REFERENCE „go Dltltl3 FF=la.af FINISHED GRADE TO N.G.V.D. (M.S.L. 1929). < Alden W. Young, P.E & L.S. (1908-1994) s �ff 15.3 15.1 14.4 3. THIS PARCEL IS LOCATED IN FIRM ZONE �j� Howard W. Young, Land Surveyor -�/ Thomas C. Wolpert, Professional Engineer A4 BASE ELEVATION 8.0 AS INDICATED ON Kenneth F. A6ruzzo, Land Surveyor 0 FLOOD INSURANCE RATE MAP PANEL NUMBERED John Schnurr, Land Surveyor Z �Ilaa>tia9 IE=13.3 IE=13.1 1000 Gas IE=12.a s' 360813 0116D LAST DATED AUG. 16, 1993. °N o � W o -� o $agin�rriag SEPTIC TANK �SSPDoI 4. ■ = MONUMENT FOUND v°lj o a$go GROUND WATER = 1.4 3' MIN. 5' 5. A = STAKE FOUND UPLAND AREA: 6. • = LATH SET <_a AREA = 38814 s.f. DZ5 o % Lot 8 PERCENT OF UPLAND COVERAGE HF. Z / HOUSE & GARAGE = 2500 s.f. OR 6.4% Az to (Vacant) g� PATIO = 1600 s.f. OR 4.1% R�9;j PORCH = 412 s.f. OR 1.1% I i FIRM ZONE / �,� �P�a POOL = 800 s.f. OR 2.1% s`3 rcFoo BOUNDARY UNE P��"Q DRIVEWAY = 1993 s.f. OR 5.1% � z Z 1 / .,�r1� TOTAL = 7305 s.f. OR 18.8% o<< 03 < S 6). / a`ti' a < ' \ FIRM ZONE Dc$ . f��lq 1 44*5 ., �' offi'iZZ {J BOUNDARY LINE 1 At� �'y S 1Q O Q c / `� K o PLACE HAYBALES OR ` 6 QQ , 0� G �1 SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES CERTIFICATION 9 SILT FENCE DURING ` 1 \ \ Lot 9 I "I AM FAMILIAR WITH THE STANDARDS FOR APPROVAL AND CONSTRUCTION OF SUBSURFACE _fig! �' I I CONSTRUCTION \ SEWAGE DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES AND WILL ABIDE BY THE CONDITIONS <�Z� III \7 \ ' » \6 \' Area �= 47777 s.f. ��` ^'� SET FORTH THEREIN AND ON THE PERMIT TO CONSTRUCT.' � �<, X8'1510 E 136.79 may\ \ 6 6 /�qQ W Fd-r. \ 59 84 20 ' \ \\ moo, 1 of , APPUCANVS SIGNATURE: a�� n \\ 4.33' PROPOSED W / U (,,l SANITARYV6 APPLICANT: O tae S.T. i SYSTEM \ O 6 --` / VVV \� ztr • T STREET ADDRESS: W yT _ ��y0y I P i w>v a m CI W CITY: STATE: ZIP CODE: �skoH 0 0 o m moo \ N TELEPHONE NUMBER: a4bIF Ni I T Ohm U �gWz I o 1 lJ \1P1�\ I\ vm ts. _ 61.0. N 15 O �� 1 - PROPOSED -I N (n SURVEY FOR: ATER SERVICE v M W� -� JAMES F. DON OH U E N4� 25 O _ 25.61r I '\ LOT NO. 9 "HARBOR VIEW AT MATTITUCK" a� $ •�• O OD n �O' O "^ti c,+ \° II N I N \ oo At: MATTITUCK Town of: SOUTHOLD ' m j 1 I N PROPOSED DR VEWAY �, _sdDj_ I ; ----�- Suffolk County, New York m� ,- -- Z !63.73-10 I TEST HOLE . FS IEL=6.91 I E11=1 4. z8m$ 1 90.23' 63.73 EL=12.4 125.00' FROM FILED MAP =-o' ;I 1000 115 17 17.9 S 8 151 0'� W I 278.96 Suff. Co. Tax Map: I I I I 1 I I 1 EL=12.5 0' District Section Block Lot 5 TOPSOIL aim AND LOAM CERTIFIED TO: 1 11 li II I 50• JAMES F. DONOHUE aim 1 1 1 1 SUFFOLK COUNTY NATIONAL BANK $ T 111 11 I I FIDELITY NATIONAL TITLE INSURANCE COMPANY 0 v" a1 1 1 I SAND OCT. 2, 1997 ro z v I II I I Q 12' DRAINAGE EASEMENT JULY 31, 1997 0< 5 ai LOt OUND WATER to Z z> GR11.1' JUNE 26, 1997 6 �0No EL=1.4 JUNE 18, 1997 < .0 W�N� 1' (Vacant) I I JUNE 9, 1997 4a4.0W oo WATER IN DATE : JUNE 2, 1997 C:F40 SAND SCALE :1" = 50' ooh" "ice JOB NO. :97 - 0297F O Z o> 15.0' SHEET N0. :1 OF 1 EqE 9 "D0970297.DWG" J• . O O NOTES: Young & Young, Land Surveyorso SANITARY DETAIL 1. SUBDIVISION MAP FILED IN THE OFFICE 400 Ostrander Avenue, Riverhead, New York 11901 OF THE CLERK OF SUFFOLK COUNTY ON '9 � 9W Dun SEWAGE DISPOSAL SYSTEM - 2 POOL AUG. 21, 1987 AS FILE N0. 8377. 516-727-2303 g HOUSE N.T.S. O 2. ELEVATIONS SHOWN HEREON ARE FROM O Ql� ACTUAL SURVEY AND ARE REFERENCE �H�o FF=18.0t TO N.G.V.D. (M.S.L. 1929). < Alden W. Young, P.E & L.S. (1908-1994) 0x$9 FINISHED GRADE IIUIi� 153 151 '9� Howard W. Young, Land Surveyor 14.4 3. THIS PARCEL IS LOCATED IN FIRM ZONE Thomas C. Wolpert, Professional Engineer A4 BASE ELEVATION 8.0 AS INDICATED ON Kenneth F. Abruzzo, Land Surveyor 0 FLOOD INSURANCE RATE MAP PANEL NUMBERED John Schnurr, Land Surveyor lannittq IE=73.3 IE=13. IE=12.6 IE=12.4 00 'o 360813 0116D LAST DATED AUG. 16, 1993. 0 1000 GAL 6' a a . £ngiarrring SEPTIC TANK CESSPOOL 4. ■ = MONUMENT FOUND h c "msso 3' MIN. 5' R W GROUND WATER = 1.4 , 5. A = STAKE FOUND > mryin9 = = = - - UPLAND AREA: 6. • = LATH SET IaN AREA = 38814 s.f. o�z� PERCENT OF UPLAND COVERAGE _ I Lot 8 �o$F I HOUSE & GARAGE = 2500 s.f. OR 6.4% ;W2 (Vacant) c�� PATIO = 1600 s.f. OR 4.1% C+% oK�` PORCH = 412 s.f. OR 1.1% o < POOL = 800 s.f. OR 2.1% �X-. DRIVEWAY = 1993 s.f. OR 5.1% I � \ S h`L � TOTAL = 7305 s.f. OR 18.8% G Np C I I F(` 440 , 1 b1i '4S ,'0QO Oy / `� �f i \ PLACE HAYBALES OR ` 6 0' , J SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES CERTIFICATIONS"_� i SILT FENCE DURING `_ 1O \ Lot 9 1 "I AM FAMILIAR WITH THE STANDARDS FOR APPROVAL AND CONSTRUCTION OF SUBSURFACE � � �j= III \ CONSTRUCTION \ \ SEWAGE DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES AND WILL ABIDE BY THE CONDITIONS <WF ` \ ` Area \= 47777S•f• F(a \ SET FORTH THEREIN AND ON THE PERMIT TO CONSTRUCT." Faiv 7 \ \\N\ 8'15'10" E 136.79 \ \`6 \ \ ss F I\ \\ 59 84 20 \ \ kE o h APPLICANT'S SIGNATURE: $ \ \LA. 35.0' ✓ _ �I \\ " \\ 4.33' PROPOSED f 8 APPLICANT: O (G\ SANITARY�\ la.s ss' S.T. / SYSTEM \ 0 /y ��'�•\\�\--� -- 6 _-` I \� 1,1T • � `� d- STREET ADDRESS: \\ `�\ •�_--- �/ 111 20 CITY: STATE: ZIP CODE: o00 0 ozo� "•_ � � C� TELEPHONE NUMBER: dSNg 9.33 IP\ 1\ 8� m ts. 61.0' �__ cV Zoo - PROPOSED -I N (!) SURVEY FOR: = W I _ WATER SERVICE � w c� JAMES F. DONOHUE P.�� 25AS' J J M9 U,x F5 03 99.3'_ 3 "HARBOR » off$ �I--+ --.r I ,� s a a o I I II LOT N0. 9 HARBOR VIEW AT MATTITUCK `� 0 m ji 1 ', II 1 p N N PROPOSED DR VEWAY I At: MATTITUCK Town of: SOUTHOLD =° D sdDj___. Suffolk County, New York m�0, 1 Z ; -�- I I \ TEST HOLE lEL=6.9I EL=12.4 '12 •DD� E =14. :�W g 92.23' 163.73 FROM FILED MAP 1000 115 17 17.9 S 8�' S'�10'� W 278.96' Suff. Co. Tax Map: I L t I EL=12.5 0' District Section Block Lots <> II II I ' TOPSOILS<m AND LOAM iso I I CERTIFIED T0: I I 5.0' JAMES F. DONOHtJE " o 'v 01, n SUFFOLK COUNTY NATIONAL BANK 8 W No z n III II I I SAND FIDELITY NATIONAL TITLE INSURANCE COMPANY 0 ox CA 0 O�`nr II II I Lot I O GROUND WATER 12' DRAINAGE EASEMENT -1 JULY 31, 1997 L.�5 11.1' JUNE 26, 1997 z�0 �I ' (Vacant) d EL=1.447109:u� JUNE JUNE19, 1997 8iZ� a c)�: I I WATER IN DATE : JUNE 2, 1997 W�"< C) my SAND SCALE :1" = 50' ��ax JOB NO. :97 - 0297 HO 15.0' SHEET NO. :1 OF 1 =s � O "D0970297.D WG" SUFF OLX Comy pgpAR O 7MEN7•OF IiEALTH SERVICES � ���� App�aovAs,oFcoNs _ Young & Young, Land Surveyors Deo A SINGLE F �ILYRESI:�ZC 400 Ostrander Avenue, Riverhead, New York 11901 £$s� 111998 �� �O 516-727-2303 a9? IIllltJ KS. f No. 0 � 7- C J a� a The Seie.at FaWO ittsticet %r:/or cetti.red Supp v ti�'�t this toc8tion h. < Alden W. Young, P.E & L.S. (1908-1994) ��g be s-atisf W p by=1fs 13PT ei�:tetit or r � been IIuit 42. sEe ncies and f Land Surveyor � •�`{'. .i,".�i OF B RAMS. ounQ to '9� Howard W. Young, /} ��-�-�-' Thomas C. Wolpert, Professional Engineer (�t� Kenneth F. Abruzzo, Land Surveyor 0 ptattniag �/�,y� St" h�A•C�}� 1�p /�■� John Schnurr, Land Surveyor >a 0mce Of W P.P.,Chief r\ � $ *send Wastewater Msusagementof / z NOTES: 1. SUBDIVISION MAP FILED IN THE OFFICE g�=a OF THE CLERK OF SUFFOLK COUNTY ON AUG. 21, 1987 AS FILE NO. 8377. �• �� Lot 8 2. ■ = MONUMENT FOUND �2 3. A = STAKE FOUND F aFQo tri R .rc • m r I �.•z� ��. �o�'�` Lot 9 SIP. c0 Area = 47777 S•f• APR. 27, 1998 REVISED CERTIFICATIONS s = I 887 cJ'1 0" E 136.79' APR. 24, 1998 FINAL SURVEY F�-F 5259 \20 ws NOV. 10, 1997 LOCATED FOUNDATION ts� 4 6 __ OCT. 15 1997 STAKED PROPOSED HOUSE �` \ ti?,; ?r• _ , ` d OCT. 2, 1997 ADDED FIRM ZONE BOUNDARY LINE 0 `, \ 1o.4•gail4.a•-u zo O JULY 31, 1997 y z°' JUNE 26 1997 ADDED CERTIFICATIONS W 0" o h/ �//�� / � w JUNE 18, 1997 08�a � o / - JUNE 9 1997 W WF Q Ott.v ` `150-:\ \ J /c C.P. N V DATE:JUNE 2 1997 REVISIONS: W �A 0-n / nm 15.9 ---- — N '. rn 60.6_ -�- SURVEY FOR: "��s . �z �. I �� N _jJAMES F. DONOHUEIn = ONS= L o -' -- --- 259 J LOT N0. 9 "HARBOR VIEW AT MATTITUCK" =� o °' 1 A ORAwp f a� At: MATTITUCK Town of: SOUTHOLD ° ry W oZ + I I Q Jo• ___J is I Suffolk County, New YorkI CL mg$y 8m ;0 25 00' 0 63.73' 11 1000 115 17 17.9 3-80 : -oma Suff. Co. Tax Map. I S 88'15' 0" W 278.9 District Section Block Lot CERTIFIED TO: Boa ' � I JAMES F. DONOHUE WW�I SUFFOLK COUNTY NATIONAL BANK 0 I FIDELITY NATIONAL'TITLE INSURANCE COMPANY ; Z SAY 071999 SNS O} O 12' DRAINAGE EASEMENT mZom Lot $ g o cn a le � �� i NNW moo I - DATE : JUNE 2. 1997 wo < o-o SCALE :1" = 50' il��x oIE is z� JOB NO. :97 - 0297 -j z s m D SHEET NO. :1 OF 1 O o� O s "D0970297.DWG' J` ZI ?9 Z b" DECORATIVE FASCIA TRIM 2 12 N 4" DECORATIVE ._ MOLDING SECOND FLOOR PL HT. a ELEV. I1'-10O LPHALT ROOF - 5HIN6LE5 (TVP) } W DECORATIVEHTrHT Ll SECOND FLOOR -�� 5HIN6LE5 (TYP) 10" DECORATIVE ELEV '1'-10" T TAPERED GOLUMN5 ' I ' -_-_ W DECORATIVE ® ® ---_ U CORNER MOLDING ® ---- --- ®� -- _ -- ® a ivECD ® � ^^ PROCEEDrRVE Z FRAMING UNTIL SURVEY (I„u_ _ OF FOUNDATION tWATNNI -- —_- -- — HAS BEEN APPROVED, z 6" VINYL SIDING ERE - - - -- -- � -- - ----- -� -� FIR5T FLOOR HEIGHT Q -- --- --- - ELEV O'-O� 6RADE UNDERWNITM CERTIFICATE W W ITEQwaEg 0 �. z G.G A TREATED HOOD Q LL 5TEP5 AND DECK _ L OCCUPANCY OR r. "R,, yre€s�S 17�ITFiB - - - - - - - - - - - - - - - - — � u J u —I I I USE IS UNLAWFUL MING ool W H" POURED CONCRETE ­")v. B.F?$ O f- L FOUNDATION HALL 7 j I I I WITHOUT CERTIFICATE Bv STEPPED FOOTING— L iER5AMN 5''-0" BELOW 6RADE GONCRETE�FOOTIN6 / OF OCCUPANCY ''�I �'9 AIT(?4 OR '"HE - - - - - - - - - - - - - - - - - / g01, P GINSPECTIONS: �/ O - - - - - - - - - - - - - - - - - - - - - J — _ 9. rGiINDATION TIVG REQUIRED n L — - - - - - - - - - - - - - - - - - — R.j;:;, PQVAIRED CONCRETE U- - - - - - - - - - - - - - - - - - - - - - - - - - - 2, ROUGH - PRAMING A. PLUMBING :NE0.ILATION 1 I I:,IA!. . CONSTRUCTION IM IST If Copper tubing is used F COMPLETE FOR C.G. O J for water distributing PLUMBER CERTIFICATION AIL CONSTRUCTION SHALL MEET ' system; piping shell be ON LEAD CONTENT BEFOIi 7HE RE4UIREMENTS OF THE N.Y.N.Y.�;T)p'tE CONSTRUCTION & ENERGv Of types K or L only PES. NOT RESPONSIBLE FOR FRONT E L E�A T I O N CERTIFICATE OF OCCUPANCY t ESIGN OR T RTRucnaB ERRORS SOLDER USED IN WATER SCALE: 1/4" = 1'-0" SUPPLYSYS7EM CANNOT EXCEED 2/10 of I% LEAD. PROVIDE 8111ORE4E1EDflN0 lMIAlANII�I'AtDAND/DR "''PLUMBING AAS TO z OK PEVE INMV RNTING 64LLPLUMBINGWASTE MI N.iNW{p�NppD, '`} '•' iMMTO PARL l02.6(KI &WATERLINESNEED r L%S=1111WING CODE. TESTING BEFORE COVERING Q W J W 12 2 �12 - Z z w Q m 4 1� C)Lu Q V O IZILZI2 0000 x= J - _ tl $ 4 � �� RIGHT ELE�/ATION 3 REAR ELE�IATION LEFT ELEVATION 5CALE: 1/8" = 1'-0" 1 SCALE: 1/8" = 1'-0" SCALE: I/8" = 1'-0" 5HT. No. 1 OF: 5 t � O~ k ` d z O F s W _ LINE OF CANTILEVER — — \ m — — — — — — — — — 7) r — — — — — — — — — —— — — - - - - - - -STEPPED FOOTING O =. � UNEXCAVATED II 1/5" TJI / 25 O Ib' O.G. 4" POURED .10K PETE SLAB W/ bx6 - IoxlO W.Y+M PROVIDE 5/b" TYPE O'✓EP b MIL POL YETHLENE GYP BD ON GEILIN6 ABOVE — ✓APOR BARRIER ON WELL STEEL I O I FURNACE FOR AT LEAST 3'- GOMPAGTED POROUS FILL ON ALL SIDES AS PER N CODE. I L_ J L — O 3" STANDARD PIPE COLUMN L — Q ON A 30 x 30" x 15' DEEP POURED p V\ II 1/5" TJ / 25 6 Ib" O.G. CONCRETE FOOTING (TYP) m DROP FOUNDATION WALL x 'ry' ;� 7 O1 /0, II V8" TJ / 25 1, '� V — m ro MEET SLAB AT a m BASEMENT I m O OPENINGS (T P) Itl - O 24" O.G I � I �: 4^ coNG. SLAB 1 s� I I I � ����" L CO GONG PIER ♦Q H"x16" (TYPJ II 1/8" TJI / 25 ® 16" O.G. LINE OF BUILT-/ r — — Q 6/ Q UP FLOORING ABOVE CENTER LINE 2'W2 F J 6 16" O G OF BASEMENT I W U q' G G A LUMBER L J 3_T• - L * J r 0 29'fi 2`10' -7 o OL r x I lL 4 . 7 m (2) F.J. �L— STEPPED FOOTINGS / /` 4" POURED CONCRETE SLAB . ` / OVER 6 MIL POLYETHLENE -. LL. VAPOR BARRIER ON WELL ro COMPACTED POROUS FILL - - - - - - - - - - - - - — — — - - - - - - 2" x O I6" O.G. Ali V (2) F.J. I m r v K In I 8" POURED CONCRETE FOUNDATION m WALL ON H"xlb" POURED CONCRETE n GONG, PIER FOOTING (— .�, b"x16" (TYP) — `ry.' I — — — — � ' z s = � � - - - - - - - - - -� - - — — - - - - - - - — — - - - � EL _ _ _ _ _ _ w N — — — — — — — — — — — — — — — — — — — — — — — — — 2"x8" LEDGER (�ONTINUOUSI — — — — — — — I I 1VI',+S 42'_B. _i 6'4' 24'-3' , U -j (2) 2'x8" HDR. (2) 2'x8" HDR. (2) 2'x8" HDR (2) 2"x8" HDR. (2) 2"x8" HDR. (2) 2"x(8" HDR f' - - - - - - - - - - - - - - - - - - - - - - - - - - — Lu 0" r 10" DIA POURED� CONCRETE PIER. (TTP) r —rel Q 5 L � �W a� mix S " �� a O FOUNDA7I0N PLAN SHT. No. 2 5 LF � F + z 5 O H 33.6• 9'-0' 14'3' 5'11' 9'-0' T'-4' V 3p_Ip• 2-10' 2-0' 2-6' 2-b' 2-0' b-10' l-T 4-b' 1-3 2-0' 2-6' 2-b' 2`0' T-4' W GGA TREATED WOOD PRE-FAB �A _ � STEPS - - _ -TO GRADE. (TYP) CHIMNEY _ U 1. - GW145-2 __ - - 1 fGWI 5-2 VENT DRYER TO OUTSID FN9,11 GI 0611-4 c FII S -- - _— � tl/4" (2) 13/4' x II I/4 TEMPERED e < jpY GLASS <� I SPYLLI FLAB TO SLOPE °o 16" FLUSH O ry USTONE HEARTH I ry 1 DN 4" TO DOORS p m ^° BRKFST p 'U FP.5G METAL- 25, ETAL 23 I ryb p 4, 15'-4-_6" 0 DOORS FRAME -T-'i __ - 4° 10'-B• n q I5 , +" 131-01 p' b'-0' +• �46' p-6° p Y .- GARAGE GREAT ROOM J Z % 4" POURED CONCRETE fV SLAB WITH bN"6 IO/10 ryCATHEDRAL I - N W.WM 4' :'-0' 4 '-B`- 2' 3'-4' 2'-4" 3'-4 2'-0' iv — (—��, A TER D ❑ -OTIS - - _ LINE OF BALCONY ABOVE - - I PROVIDE PENINGS FOR F m ry 10 4 O 'Il (2) 1 3147, II 7/H" M:- 2) 11 3/4" xII l/8' M.L. L o� _ ry p - n 2"xl0" F.J O Ib' O.G RIDGE m N O EMERGEN YESCAPE AS - r W anlcRErE Fao x IS rYP m KITCHEN Y 2°x1o" F.J. 0 I6" oG. o ^ N.Y. STATE ILDING CODE. Q Z p 3^ STANDARD S EEL PIPE cowMN FLTUIRF 6TA1Rs I ° REQUIRED PART 714 OF ° O = ON A 30" x 30" " DEEP POURED - - 'Ib D 2\P `p O G TING (2) F.J. m z zJ — _L _ Q u x PROVIDE IA NR. FIRE 0 LL I P ry LL IN STOR J RATED SEPARATION TO LL t ON 0 SJ p O + $ PART.717.3 M(1)OF 0 6 — 1- v N.Y.STATE BUILDING CODE, LL I O FF EG METAL- 5/b' ETAL - 5/b" TYPE "X" GYP BOARD DOOR E FRAME ° x ?6 — II q > E WALLS 2"x10" F.J m I6" O.G. o N INTERIOR 6ARA6 iv O m O ri II'I AND GEIL IN6 s> j 6" Ib' I I o � EXHAUST FAN 'i I Y - - I TO EXTERIOR �I m ' 1 ' 4' 13'-0' 4• - 9,-4. ._B 3'..p. 4. ��. — — — 3052— DINING N R III - o CLOS 4•x4" WD POST5 x FOYER IN 10" DIA. DECOR i CATHEDRAL� I EDRM 5 Y COLUMNS (TYP) (2) 14" SIDEL16HT5 - - - ryb° k, n U/ ^ 6v z Q 3052 } 3052 a 3052 3052 1 -_ + J J 0. - a- - -- -- - --- -- - J 0 -- — ERiENCFE_ PEAS n — n _ — — '- - - - ' - - - - w 1:5- 1 0'-4' 12' 9'-0' 1 m 12' I '-4• 10'-4' 12' Y Z 1141' Y-5" 6'�' V Q (((��� = O 5'-II' 12'-4" p Q -1 30i_2. 42'-b' 64' I 5 E.0g PV T g�1 �' C C O F I RST FLOOF, FLAN c g SCALE: 1/4" = 1'-0" LIVING SQ. FT. = 1839 S.F. N GAR,4GE SQ. FT. = 100 S.F. SHT. No, 3 OF 5 'ts z F D- C)C) // p-R // 2" b" R.R. 1 2'x6" R R. 2"xb" R R '� // or w 12,_10. J I O O O 24'-2' g'-4" 424' '4 ROOF BELOW K 1 LL ry I III _ FUTURE STORAGE _ OPEN OO EDRAL TH — p V 5068 SLD 5068 5LDz Q 5066 SLD 5068 SLD a z / HANDRAIL FU y Lu 1 — -- EXHAu5TFAN .o- O / TO EXTERIOR I p y ��l O Q• - I ;� BEDROOM BEDROOM '� J � i - - si q PROVIDE OPENINGS FOR o qry x ry I EMERGENCY ESCAPE AS ROOF BELOW 13'4' 4' FR 151-01 ' 4' REQUIRED BY PART. 714 OF ° N.Y. STATE BUILDING CODE. 714 DF EMERGDB RE4�IREPROppE AS SI ATEBUIIING 15 DN ZOQ I m � I III I I I I OPEN TO BELOW - 1, z O ' R.R ' 16' O.G. • Ib'O.G I i • ' OL i • 'OL. Q — - 30310 1 U D PI0310 Ad+32 DHPIO 10 I — 30310 O r p GTCXWI w I � I 24'-2• 4'-6' 2'-4' 2'-4' O 4,4• 3'-2' 3�_2. 1' ROOF BELOW d I 2 m l2 Lu Nt Q 4 C) (, 5 �W $ z n�8 g� �v s C 3EOON17) FLOOR FLAN O a N SHT. No. 4 OF 5 GENERAL NOTES rR� (TYP) ROOF rl , iL I, CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS TO THE SITE 15. MAINTAIN T' MINIMUM CLEARANCE BETWEEN ALL STRICTURAL FRAMING "_ _'= ro PRIOR TO STARTING OF WORK AND HE SHALL FAMILIARIZE HIMSELF WITH MEMBERS AND FIREPLACE OR CHIMNEY MASONRY 21 PLYWOOD DECKING SHALL BE EXTERIOR GRADE PLYWOOD WITH EDGES 2� y - E THE INTENT OF THESE PLANS AND MAKE WORK AGREE WITH SAME SOLID BLOCKED OR PLY CHIPS. I � � I �s I(, ALL FLOOR JOISTS SHALL BE LATERALLY SUPPORTED BY BRIDGING OR 2 OWNTRQC LL E PRIOR T SHALL OBTAIN A BUILDING PERMIT FROM THE BLOCKING e INTERVALS NOT EXCEEDING EIGHT FEET 28 ALL STRUCTURAL STEEL SHALL 8E A-36 STEEL AND SHALL BE TOUCH OR VILLAGE PRIOR TO STARTING WORK INSTALLED AS PER A.I SO I I 1�-2'v �-IyIW 3 CONTRACTOR SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, 17 ALL FLASHING SHALL BE ALUMINUM 29. ALL DRYWALL SHALL BE UBG NATIONAL GYPSUM CO 1/2" THICK, I �4y°V I I I CERTIFICATES OF OCCUPANCY, INSPECTION APPROVALS, ETC, FOR WORK 15. ALL RAFTERS SHALL BE ANCHORED TO FRAMED WALLS WITH "HURRICANE TAPED AND 5PACKLED THREE COATS. PERFORMED FROM AGENCIES HAVING JURISDICTION THEREOF CLIPS" c I6" ON CENTER 30 ALL DRYWALL SHALL BE PRIMED AND PAINTED (2 FINISH COATS). EXISTING I I WL LAV I LAV I 4. ALL WORK SHALL CONFORM TO THE NEW YORK STATE UNIFORM FIRE 19. ALL INTERIOR DOORS SHALL BE STAIN GRADE 6'-e" HIGH X 1-3/8" HOUSE \ I I PREVENTION AND BUILDING CODE AND ALL RULES AND REGULATIONS OF THE THICK x WIDTH AS NOTED ON PLAN WITH APPROPRIATE HARDWARE. ALL 31 ALL MOLDINGS AND TRIM SHALL BE STAIN GRADE, AS SELECTED BY TOWN. DOORS SHALL BE FINISHED AS PER OWNER OWNER- I I I 5ECOND � 5. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS WHICH 20 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SUPERCEDE SCALED 32 ALL FINISHES (INTERIOR AND EXTERIOR) SHALL MATCH EXISTING AS 4' RR 1- DISAGREES WITH THAT A5 INDICATED ON THESE PLANS, THE CONTRACTOR DIMENSIONS. ARCHITECT HAS NOT BEEN RETAINED FOR CN SITE CLOSE AS POSSIBLE I 2' lye" I CO 2 SHALL STOP WORK AND NOTIFY THE ARCHITECT. SHOULD HE FAIL TO INSPECTIONS AND/OR OBSERVATIONS OF THE CONSTRUCTION. FOLLOW THIS PROCEDURE, AND CONTINUE WITH THE WOW, HE SHALL 33 CARPETING SHALL BE SUPPLIED AND INSTALLED BY THE OWNER _ _ ASSUME ALL RESPONSIBILITY AND LIABILITY ARISING THEREFROM. 21 DRAWINGS AND SPECIFICATIONS AS IN5TRUMENT5 OF SERVICE ARE AND T T� SHALL REMAIN THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT 34. OWNER SHALL SELECT ALL COLORS, J \p I T _ LNLI 6 GRADING AROUND NEW CONSTRUCTION SHALL SLOPE AWAY AND BLEND INTO FOR WHICH THEY ARE MADE IS EXECUTED OR NOT THEY ARE NOT TO BE r I j1'I'V �-IbUN �Iy1 V `'�-2'V I �14a'V I T C) EXISTING. USED ON ANY OTHER PROJECTS OR EXTEN51ON5 TO THI5 PROJECT ExGEPT 35 ALL PLUMBING SHALL BE IN STRICT CONFORMANCE WITH NEW YORK �11�1'V I I I I -Ily^y I �--yV I�'V �115'V BT AGREEMENT IN WRITING AND WITH ADEQUATE COMPENSATION TO THE STATE BUILDING CODE THE NEW FIXTURES INTO EXISTING SANITARY 1. ALL FOOTINGS SHALL BEAR ON UNDISTURBED SOIL WITH A MINIMUM 501L ARCHITECT SYSTEM. I WASHER 15w i 5NR I I I I I I SBm I PRESSURE OF 2 TONS PER SOFT AND SHALL HAVE A MINIMUM OF 3'-0" ILAY WL I LAV ILAY WC, BD. I I OF COVER 22 PATCH 45 REQUIRED ALL AREAS WHERE EXISTING HAS BEEN REMOVED 36 CONTRACTOR SHALL DETERMINE WHETHER THE EXISTING ELECTRICAL I / I IFTF AND/OR NEW WORK ABUTS EXISTING WHERE EXISTING WALLS ARE REMOVED SERVICE 15 SUFFICIENT TO SERVICE THE NEW ADDITION AND SHALL ° 8. ALL CONCRETE SHALL BE 2500 PSI CONCRETE o 28 DAYS OR NEW OPENINGS ARE CALLED FOR IN EXISTING WALLS, PRIOR TO NOTIFY THE OWNER ACCORDINGLY ALL ELECTRICAL WORK SHALL BE BOARD I TUB I I TIB REMOVAL OF EXISTING WALLS, CEILING BEAMS, ROOF RAFTERS, ETC., OF FIRE UNDERWRITER APPROVED. INSTALL AS PER OWNER'S DIRECTION IW10I FIRST 5. DESIGN LOADS: FIRST FLOOR - 65•/SF LIVE LOAD CONTRACTOR SHALL BRACE EX15TING 45 REQUIRED UNTIL NEW HEADER AS ANY AND ALL INTERCOM, TELEPHONE, AND/OR TV ANTENNA WIRING IN ROOF - 50'/SF - LIVE LOAD SPECIFIED 15 INSTALLED, WALLS PRIOR TO INSTALLATION OF WALLBOARD ALL TEMPERATURE lye ly' 4' 4' _FLR Ell SECOND FLOOR - 50•/5F LIVE LOAD CONTROL WIRING SHALL RUN CONCEALED IN WALLS, FLOORS, AND/OR T 7" CO IIILYYYH CEILING - 30•/SF - LIVE LOAD 23 CONTRACTOR SHALL REROUTE AS REQUIRED ALL EXISTING PLUMBING, CEILINGS VERIFY OUTLET, SWITCH AND LIGHTING LOCATIONS WITH ELECTRICAL, AIR-CONDITIONING, AND HEATING LINES WHICH INTERFERE OWNER PRIOR TO INSTALLATION. 10 DESIGN TIMBER 6TRE66 - DOUGLAS FIR SOUTH,NO 2 GRADE FB WITH NEW CCN5TRUCTION 31 DOUBLE JOISTS UNDER ALL PARTITIONS PARALLEL TO FRAMING AND �P.VC PIPE PITCHED 24. ALL "MICRO=LAM" LAMINATED VENEER LUMBER TO BE DOUGLAS FIR AS PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS GOiWECT TO APPROVED A5 PER N.Y.S. CODE 825 P51, E - I]00p00 12 ALL HEADERS SHALL BE ON OTHERWISE OST • 2"X4" WALLS IN MANUFACTURED L TRUS JOIST CORP OR EQUAL SIZES AS ONFO MA ON FA.I. 1 SANITARY SYSTEM " 1 WALLS 4 (3) 2"XB ■ 2'Xb" WALLS UNLE59 NOTED OTHERWISE PLANS MICRO-LAM INSTALLATIONS SHALL BE IN STRICT CONFORMANCE 38. THE CONTRACT DOCUMENTS GENERALLY INDICATE THE SCOPE AND DUALITY WITH MANUFACTURERS 51-ECIFICATICNB AND RECOMMENDATIONS OF THE WORK, BUT ARE NOT PRESENTED AS BEING FREE FROM ERRORS OR OR 4"X6" OMISSIONS, AND ANY WORK CALLED FOR IN THE SPECIFICATIONS AND NOT POST i 2"x6" WALLS UNLE66 NOTED OTHERWISE, 25, ALL METAL J015T HANGERS AND OTHER METAL CONNECTORS REQUIRED SHOWN ON THE DRAWINGS AND NOT CALLED FOR IN THE SPECIFICATIONS 15 TO SHALL BE "TECO CONNECTORS" OR EQUAL AND SHALL BE CAPABLE OF BE PERFORMED AS IF THE WORK WAS CALLED FOR IN BOTH. ANY AND ALL 1 �, „D I N O RISER I S E R 13 FURNISH AND INSTALL SINGLE STATION SMOKE DETECTING ALAR? HANDLING LOADS • CONNECTION POINTS. INSTALLATIONS SHALL BE IN WORK AND ANY AND ALL MATERIALS NOT LISTED IN THE BID DOCUMENTS THAT M' DEVICE IN COMPLIANCE WITH NEW YORK STATE BUILDING CODE. STRICT CONFORMANCE WITH MANUFACTURERS SPECIFICATIONS AND ARE REQUIRED OR CAN BE REASONABLY OR NORMALLY BE INTERPRETED OR W RECOMMENDATIONS, INFERRED, THEREFORE, SHALL BE FURNISHED AND INSTALLED BY THE 14. ALL WINDOWS SHALL BE WHITE PERMA•SHIELD WITH HIGH PERFORMANCE CONTRACTOR �� Q GLAZING AS MANUFACTURED BY ANDERSEN WINDOWALLS OR EQUAL. INCLUDE 26 DOUBLE JOISTS UNDER ALL PARTITIONS PARALLEL TO SAME AND AROUND INSECT SCREENS AND JAMB EXTENDERS AS REQUIRED. ALL OPENING5. V �( w Q TYPICAL ROOF CON5TR)GTI0 a: ZN ASPHALT SHINGLE ROOFING Q OVER IS>• ROOF FELT ON I/2" GDX PLYWOOD SHEATHING. 2" x 10" ROOF RAFTERS AT 16" OG Lu N1 2"x14" RIDGE BEAM I I I �yN W � 1~- 2 12 n, I TYPICALCEILINQ OON5MRUCTI0N 12 12 2"xl0" JOISTS OISTS ® I6" G W/ MIN R-19 BATT INSULATION I/2" GYP BO. FIN15H ROOF a ER SUMMARY OF TOTAL THERf1AL RATING TIES ® 4H"48" O G RPRE-FAB DECORATIVE TIES HIIRRIL,WE CLIP NAILED CHIMNEY CAP O To AAPrele � 9-ATE IF THE TOTAL THERMAL RATING IS ZERO ('0)OR GREATER,THE !51 PROPOSED DESIGN FOR THE BUILDING ENVELOPE COMPLIES W/ Q r2&W' TOP PLATES THE ENERGY CODE. p THERMAL TABLE ° AREA U-VALUE RATING USED ° ° ° A. WALL ASSEMBLY Al NET WALLS 2b90710 0 IDI .233 6-1 `? i j r^I— __ m �.I L�I 42 GLAZING 43SM + 32 -10 6-1 PI R � LUh A3 DOORS 80.00IDI .7 b-I 2" x 10" F 1 0 16" OG. Z 2"x6" RR - 3/4" PLY OD SHEATHING W t SUBTOTAL THERMAL RATTING FOR SECTION A (AI.42.A3) •170 (2) 2"x10" HDR ® I6 O G. _j Z O W/ WOOD BLOCKING � W Q F­ B. ROOF/GEILING ASSEMBLY _I O42 H- BJ W 2 1 iJRRI cf A YE CL I � �E7A L . ROOF/CEILING 2,813ID � 0 6-3 ALUM. GUTTER ON g Z 1 B2 SKYLIGHTS '42 6-3 yxb" G J. �1/2" GYP FINISH --TY 5 SCALE: N.T.S. r LU 5U8TOTAL THERMAL RATING FOR SECTION B (BI-B2) 0 x GI D. — r — � PIGAL WALL GONSTRUGTION TYVE TAPERED COLUMN (TYP) ® Ib O.G. I Q TYPICAL FLOOR CONSTRUCTION 602 2R"KGH WD, STUDSS®E6 ON SIDING ��1I11 D FOAM BAGKER 10'A DIA. DECORATIVE © LLQ OUSEWRAP rIt 2' GDX SHEATHING C FLOOR ASSEMBLY IIIII���'` x4' ' OG. CI FLOOR 2813ID s .046 0 6-3 11 P 11 l/8 T J I / 25 SP a 16" O.G P-13 INSULATION u NOOK I^U MIN R-19 BATT INSULATION. 3 V z Cl FOUNDATION WALL G.G.A. TREATED WOOD 3/4" PLYWOOD SHEATHING DECK AND STEPS 11��11 1II���11 Q 111 [A WALL PERIMETER _FLET Q Q �O ABOVE GRADE EXPOSURE O FT SHINGLE RIDGE CAP RIDGE VENT INSULATION DEPTH uys P 24' 8 48" — - (3) 1 3/4" x 11 1/4" ML HEADER __ SE Y` e 84" FOOTING UI` _ — — _ _ �__ - __— — T - .— GRADE �w 3 SHINGLES .. ' , —,111-111=�=III _ _ _ _ FELT PAPER I/° ' OSB ROOF SHEATHING (TTP.) 11111PERIMETER R-VALUE —III—III-III-III— III IIT III—I 11!111 �`x 'II-III=1 III-III--II!=1 -_1 li x C3 SLAB EDGE INSULATION - 1R 1171 IMIII-1I RAFTER SUBTOTAL THERMAL R4TING FOR SECTION G 10" DIA. POURED GONGRETE '1I 1111=CTI =�'- - W PIER MIN 3'-0" BELOW GRADE TOTAL THERMAL RATING 'LII I1 1,11111111 1 16" WIDE x 8" DEEP POURED O RIDGE BEAM CONCRETE PIERS — ` -- - ��M�M`ii• TYPICAL FLOOR GON57RUGTION 3" DIA STANDARD WEIGHT 8" POURED CONCRETE FOUNDATION WALL w 4" POURED B STEEL PIPE COLUMN ON A H"xlb" POURED CONCFOOTING. OVER L ETHN ON A 30" . 30" x B" VAPOR BIPER E GRETE C 0 p VENT/ 1�EDIn GOMPAGTED POROUS FILL FOOTING. (TYP) pu) 3 RIDGET DE7A L t 5HT. No. -5 6GALE: N.T.S 4 SEri7I O �i 5 SCALE: 1/411 = I'-m" OF 5