Loading...
HomeMy WebLinkAbout48587-Z s-- ¢�0�0 cpG��t Town of Southold 5/3/2023 E P.O.Box 1179 o _ � 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44067 Date: 5/3/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 900 Beachwood Ln, Southold SCTM#: 473889 Sec/Block/Lot: 70.-10-58 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/11/2022 pursuant to which Building Permit No. 48587 dated 12/13/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar to existina single family dwelling as aapplied for. The certificate is issued to Stuart, Susan of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48587 2/24/2023 PLUMBERS CERTIFICATION DATED ut ori 61 ignature o�suFFo TOWN OF SOUTHOLD BUILDING DEPARTMENT C41 x TOWN CLERK'S OFFICE "oy�• ao� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 48587 Date: 12/13/2022 Permission is hereby granted to: Stuart, Susan 1823 Frenchtown Rd E Greenwich, RI 02818 To: Install roof mount solar to existing single family dwelling as applied for. *Solar disconnects must be located on the exterior, labeled and readily accessible. At premises located at: 900 Beachwood Ln, Southold SCTM #473889 Sec/Block/Lot# 70.-10-58 Pursuant to application dated 10/11/2022 and approved by the Building Inspector. To expire on 6/13/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector pF SO!/T�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(cD-town.southold.ny.us Southold,NY 11971-0959 Q�yCOUNT`1,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Susan Stuart Address: 900 Beachwood Ln city,Southold st: NY zip: 11971 Building Permit#: 48587 Section: 70 Block: 10 Lot: 58 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Sunrun Soalr License No: 33878ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 11.47kW Roof Mounted PV Solar Energy System w/ (31) Vikram 370W Modules, 60A AC Disco, Combiner Notes: Solar Inspector Signature: ate: February 24, 2023 S. Devlin-Cert Electrical Compliance Form souyOlo # # SO TH TOWN OF LD BUIL ING DEPT. �o u o courm��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: C6VA as- 5-0 lVAA-,, ZdzgZaW Go- DATE INSPECTOR OF SOOTyO -- - # # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] ULATION/CAULKING [ ] FRAMING'/STRAPPING [V FINAL�;,l,,/' [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL yREMARKS: Obvm& �n ✓ r DATE v?l' INSPECTOR dA.91t.OFS(�l�f91 s� �. March 6,2023 sfi"r"uptura ENGINEEf2� Subject: Post Installation Approval Letter Job Number:216R-900STUA; Rev: B Client: Susan Stuart Address:900 Beachwood Ln,Southold, NY, 11971 Attn:To Whom It May Concern The purpose of the review was to verify the installation is in conformance with the permitted plan set and that any potential modifications from those plans meet the intent of the permitted plan set. The PV racking system's attachments have been observed to be installed in conformance with the permitted plan set.The installation complies with the code provisions listed below. •2020 NEW YORK STATE RESIDENTIAL CODE WITH 2018 IRC/IBC/IEBC,ASCE 7-16, NDS 2018 •Basic Wind Speed V= 128 mph, Exposure: B •Ground Snow Load=25 psf Paul Zacher,P.E. Professional Engineer T:916.961.3960 x101 `� OF NE�yY email: paul@pzse.com K• Zq � CyO 11) FR 19 lie XPO91365z A��FESSIONP� 03/07/2023 'IELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) c H ------------------------------------ 8 C t�7 FOUNDATION (2ND) 16 z 0 O H � ROUGH FRAMING& PLUMBING ^O 1 INSULATION PER N.Y-. y STATE ENERGY CODE 3 s LA FINAL 3 i ADDITIONAL COMMENTS Kb d 900 a3 r��Givc�C, �� s d in�o' ',� ,ecviaions s s o a3-a3 �l e-.0 rn S b H N O z H x d r� b H y`SUfFO(�c. }mos ooy;,J TOWN OF SOUTHOLD—BUILDING DEPARTMENT H z Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 a,y • oma ; Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D �� PERMIT NO. b s� Building Inspector: OCT 1 1 2022 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an BUILDING DEPT. Owner's Authorization form(Page 2)shall be completed. TOWN OF SOUTHOLD Date: f Z OWNER(S)OF PROPERTY: Name: �SG�✓1 S T- �( SCTM#1000- 60 O UD . �0 . . ()S-& Co(: Project Address: �0 C4 p if 971 Phone#: L_W Email: S U� c4n S-FLk Cog Mailing Address: CONTACT PERSON: N&LlnS Name: N) (w — / ahrw f Mailing Address: Phone#: L Email: DESIGN PROFESSIONAL INFORMATION: Name: pervl Mailing Address: /� Q J Phone#: I (.Y, 9�l' 3 c Ci Email: C(�( G' ID,? rn CONTRACTOR INFORMATION: I Name: ; J Mailing Address: vie / ll Phone#: � � G13[ Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: �26ther �l) ((ice' $-39�9c0 -CO Will the lot be re-graded? ❑Yes N4410 Will excess fill be removed from premises? ❑Yes o 1 L7.. >3:5,5 1j ;.; PROPERTY INFORMATION E9igitind Ise of propertyS ��L' 6 n e ded use of property 77_ ReRiWP6§W s-tr.ict irr" hich premises is situated: Are there any covenants and restrictions with respect to __.___...___...._.._ _. _. _..___-.-• this property. ❑Yes &Y­ this IF YES, PROVIDE A COPY. h; k 5m c After,,Reading: The owner/contractor/design professional is responsible'for all drainage and storm water issues as provided by F aA%dr•� j of the'Towii"Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone "Ordinathce of'the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additioris'alteafions or for removal or demolition as herein described.'The applicant agrees to comply with all applicable laws,ordinances,building code, `oiising code and regulations and to admit authorized lnspectors'on premises and in building(s)for necessary inspections.False statements made herein are rpunisH'atile as^;Cl s A'misdeibi anor pursuant to Section 210.45 of the New York State Penal Law. (S�i Appli, :;:port Submitted By(print name): vu/)5 uthorized Agent ❑Owner a�5anr�e,c{iApplican I � Date: T. L 114' ye YV S GJ STATE-OF"NEW YORK) 001m lacf! re r,'(, -is& 000 NTY:OF` ) :1 ; being duly sworn, deposes and says that (s)he is the applicant (Name of:individual signing contract) above named, IS)he',I�I he eG� (Contractor,Agent, Corporate Officer, etc.) '..of-sai.d,u,wne.rcor�own e,rs;:and is duly authorized to perform or have performed the said work and to make and file this application;phot,all.statements contained in this application are true to the best of his/her knowledge and belief;and `r that,thewbrk:will be.performed in the manner set forth in the application file therewith. ;S'wor,n-�befoee me this, �s h`+,aaY�f 20 Notary Public DAVID J MACKEY ... nei Notary Public,State of New York PROPERTY OWNER AUTHORIZATION Reg. No.01MA6381235 (Where the applicant is not the owner) OuaflMeu in Nassau County - Commission Eixpires October 01,2026 Susan Stuart ;I residing at �x- ASunrun do hereby authorize to apply on mv.behaIf o,the Town of thold Building Department for approval as described herein. s: O:wrier's Signature Date j !san Stuart _i_Print.Owner's Name 2 opo ufMt coo s k TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 119.7.70959 • ao�� Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtoiny: ov y` r:._W4aMx Date'Received APPLICATION FOR BUILDING PERMIT - == a,e 1. ,IfF! +*:T tea,. - For Office Use Only PERMIT NO. Building Inspector: .."Y4".;i;'— '•:�'v'%'- `d'w' ";4 '+^1v1;:�:+'"WIT, Applications and.forms must be filled out in their entirety. Incomplete applications will not•be accepted. Where the Applicant is not the owner,an P`L� =•' r ;,'i c,,a?"' '; „Owner's Authorization form(Page 2)shall'be completed. r lj;,aj !4 p`.. Date: : OWNER(S)OF PROPERTY: Name: Susan Stu,art 000- SCTM# 1 Q 0 Project Address: 900 Beachwood Ln Southold NY 11971 _Phone#: _(401) 580-78.41 Email: -Mailing Address j �r�� c ....,-,.v, CONTACT PERSON ,. . *Name: • f 'Mailing Address: �' s �.�,�_. .: .Ji - I Phone#: DESIGN PROFESSIONA INFO ION: Mai ng Address: `Phone Email: a\_ JWz CON INFORMATIO `Name: Mailing Address: Phone#: DESCRIPTION OF PROPOSED CONSTRUCTION >.❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated.Cost of Project;� : ❑Other $ :V1/ill the lot be re-graded? ❑Yes ❑No Will excess fill be removed from premises?:,ClYes ❑No:` .- 77, BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 W at Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(aDsoutholdtownny.gov seand(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 2� • C Company Name: , o )CJ f Electrician's Name: License No.: Elec. email: j Elec. Phone No: SJ(o• y3gF blilequest an email copy of Certificate of Compliance Elec. Address.: i -7-7 Gtn 12- JOB SITE INFORMATION (All Information Required) Name: s(/SG. . Address: -/ Cross Street: Phone No.: L401 . M-Cli Bldg.Permit#: jg'7 email: ins Tax Map District: 1000 Section: --,)0 Block: / Lot: j toe BRIEF DESCRIPTION OF WORK,lINCLUDES UARE FOOTAGE (Please Print Clearly): Cr �a��� off' 3� r� ���5-� Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES aNO F—]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 n2 H Frame Pole Work done on Service? Y N Additional Information: OCT 1 1 2022 PAYMENT DUE WITH APPLICATION BUILDING DEFT. TOWN OF SOU7THOLD ` JOB SITE INFORMATION (AN Information Required) YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. (415)946-7500 225 Bush Street,Suite 1400 1 c.NYS Unemployment Insurance Employer Registration Number of San Francisco,CA 94104 Insured 50-864264 Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) AMERICAN ZURICH INSURANCE COMPANY Town of Southold 3b.Policy Number of Entity Listed in Box"1 a" Town Hall Annex Building 54375 Route 25 WC 6142876-00 P O Box 1179 Southold,NY 11971 3c.Policy effective period 10/01/2021 to 10101/2022 3d.The Proprietor,Partners or Executive Officers are X❑ included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form, New York(NY) must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate.holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Samantha Furlan (Print name of authorized representative or licensed agent of insurance carrier) Approved by: c5'aM44t&l Su si 0?-2.2_-202_1 (Signature) (Date) Title: Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier: (415)538-7125 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2,Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov SUNRINC-02 TWANG ACORO® CERTIFICATE OF LIABILITY INSURANCE FDATE(MMIDDmYv) �. 9/10/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTACT Walter Tanner PRODUCER NAME: Alliant Insurance Services,Inc. PHONE FAX 575 Market St Ste 3600 (A/c,No,Et): (A/C,No): San Francisco,CA 94105 nooRlEss:Walter.Tanner@alliant.com INSURERS AFFORDING COVERAGE NAIC# INSURER A:Navigators Specialty Insurance Company 36056 INSURED INSURER B:Zurich American Insurance Company 16535 Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURER D: San Luis Obispo,CA 93401 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR D D DD A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2'000'000 CLAIMS-MADE �OCCUR LA21CGL2303211C 10/1/2021 10/1/2022 PREASEs EaENCEDn� $ 1,000,000. MED EXP(Any oneperson) $ 5,000 PERSONAL BADV INJURY $ 2'000'000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2'000'000 X POLICY JECT LOC PRODUCTS-COMP/OP AGG $ 2'000'000 X OTHER:Retention_:$100,000 Per Project Agg' $ 10,000,000 B AUTOMOBILE LIABILITY COMBINED aacgidtSINGLE LIMIT $ 2,000,000 X ANY AUTO BAP614287700 10/1/2021 10/1/2022 BODILY INJURY Per erson $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY Per accident $ AUTOS ONLY AUTO ONLY Ror a ciRdent AMAGE $ X Coo,Ded.: X Coll.:Not covered Liability Ded.: 250,000 goo, LIAB OCCUR'.'. EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION_$ C WORKERS COMPENSATION �( SER ATUTE ETH- AND EMPLOYERS' ARTNITY WC614287600 10/1/2021 10/1/2022 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N E.L.EACH ACCIDENT $ (Mandatory In NE)EXCLUDED? F N/A 1,000,000 E.L.DISEASE-EA EMPLOYE $ If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 701,Additional Remarks Schedule,may be attached If more space Is required) Workers'Compensation Policy WC614287600 Deductible:$1,000,000. Evidence of insurance CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Town Route h ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and loao are reaistered marks of ACORD YY� Workeirs'- _.: CERTIFICATE OF INSURANCE COVERAGE ATE' Com.perlsation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Sunrun Installation Services Inc. ($45) 268-2595 595 Market Street 29th Floor San Francisco, CA 94105 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to certain or Social Security Number locations in New York State,i.e.,Wrap-Up Policy) 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) The Prudential Insurance Company of America Town Of Southold 3b.Policy Number of Entity Listed in Box"l a" 54375 Route 75 CG-52830-NY P.O. Box 1179 Southold, NY 11971 3c.Policy effective period 01/01/2022 to 12/31/2022 4. Policy provides the following benefits: 0 A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named . insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed January 19, 2022 By Signa4ure of Insurance tarrle`r's'aut o�lied representative or NYS Licensed Insurance Agent of thatinsurance carrier) Telephone Number (215)784-2883 Name and Title Vice President,Contracts IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit, PO Box 5200,Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. D13-120.1 (10-17) B� (iiol X_ sp,­. f C .t7 Z- 'M Q g� qg .5� ME i k air Hr Suffolk County Doopartment of Labor, Licensing & Consumer Affairs VETERANS NIEMORIAL MGHWAY HAUPPAUGE, NEW YORK 11788 Jl 1 DATE ISSUED: 10/1/2003 r54 No. 33818-ME. Rv, zk\ SUFFOLK COUNTY U5, id Master Electrician License ��11 This is to certify that SAMY A MOUNAS doing business as NEV"", SUNRUN INSTALLATIOMSERVICES INC having given satisfactory eviderim of compet ncy,,is hereby-licensed as MASTER ELECTRICIAN in accordance e with and subject to the provisions-of applicable laws,rules and regulations of the County of Suffolk,-State of New York. Additional Businesses NOT VALID WITHOUT DEPARTMENTAL SE AL AND A CURRENT CONSUMER AFFAIRS ID CARD ;4­ Acting Commissioner V vRg Nj !..I Jo _...............__ ......_- ............ .... ... 2 _g 17�T@2 • ft System designed with �A � All parts fit in a box for easy ` maximum versatility for any � logistics arrays including staggered Drop-in features make the install process intuitive and fast Simple design allows system to �` be installed by single installer U Listed to UL Standard 2703 for on the roof L Grounding/Bonding and Fire Classification SnapNrack is designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and the highest spansof any current rail less system. Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of North-South adjustability for all Mounts Mounts • Single mount used at all locations on array • Extreme time saver by eliminating link interference through the flexibility i of the Mount to change orientation , • Features a rock-in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments .40 F7 Links • Simple design provides mounting platform between two to four modules • Clamps onto top of modules securing them in place while providing 1► row-to-row bonding • Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules • Skirt length is compatible with both portrait and landscape module orientations Quality. Innovative . Superior, SnapNrack Solar . . resources . improve overall quality and safety. . • www.snapnrack.comcontact@snapnrack.com 2019 . reserved DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins REVISION: Solar Mot 51'4`ing si'oiutiorls PART NUMBER(S): A 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO CA 94105 USA PHONE(415)580-6900•FAX(415)580-6902 242-02155 THE INFORMATION IN THIS ORE,OR USE CONFIDENTIAL AND PROPRIETARY.ANY REPRODUCTION,WRITTEN URE,OR USETNEREOF IS SOUTH 11ITEO WITHOUTTHE WRITTEN CONSENT OF SUNRUN SOUTH LLG 10 5 0 0 4 3 7 � 8 1 2 C) 6 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK, RL UNIVERSAL, LEVELER, MILL 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL 4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK 5 1 SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 1 SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS 8 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1IN, SS 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1 BOLT, FLANGE, SERRATED, 3/8IN-16 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 623 UP, 674 DOWN, 505 SIDE ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.73 DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins Sna N ruch- REVISION: Solar 4�3otin g sciutions PART NUMBER(S): A 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO,-94105 USA PHONE(415)580-6900•FAX(415)5BO-6902 242-02155 THE MDUCTIOIONIN THIS ORAWINUSCONM0Fl PA HPROPRIETARY.ANY REPRODUCTION,01R-NCE,ORTOFS REOFS PROMBITED WITHOUTTNE WRITTEN CONSENT OF SUNRUN SOUTH LLG 3.41 F 1.50 2.35 ►{ 1.50 1.55 .66 2.00 ►I 1.24 1.00 SLOT fy 2.63 ►� —1.50 ALL DIMENSIONS IN INCHES ARRAY TRUE I PV AREA SITE PLAN-SCALE=0'-0 1116"=1'-0" SITE PLAN DETAIL-SCALE=0'-01/64"=1'-0" PITCH AZIM (SOFT) ® Va .AR-01 22° 153° 119.8 00 AR-02 22° 153° 499 .4_ (E)RESIDENCE ACCESS ROOF (E)DETACHED STRUCTURE 4� AB O ° PL NOTES: FIRE SETBACKS • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE (18°TYP) SPRINKLERS. (N ARRAY AR-02 ARRAY DETAILS: S u n r u n (N)ARRAY AR-01 • TOTAL ROOF SURFACE AREA:2300 SOFT. EH°wEEan�o°Hsss as EusH sr.suHE saoo • TOTAL PV ARRAY AREA:618.8 SO FT. s wm wascc.uw+oa �MP � • PERCENTAGE PV COVERAGE: AC (TOTAL PV ARRAY AREAITOTAL ROOF SURFACE 00825-ME SE O INV AREA) 100=26.9% - muNrwcuE Hoar Hono,wEsssuav,Nv+uso PHONE BOSbtY51B] FN(B153B830a CUSTOMER RESIDENCE: SUSAN STUART 900 BEACHWOOD LN, SOUTHOLD,NY,11971 TEL.(401)580-7841 APN:1000-070-00-10-00-058-000 PROJECT NUMBER: OF NEP<y 2168-900STUA K•Z'41 0p� DESIGNER: (415)580-6920 ex3 t pa * NICHOLAS LIVELY r e � w SHEET SITE PLAN o ,o P�91365 J ROFESSIONP REV:B 2/1/2023 PAGE PV-2.O + ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:25 PSF WIND SPEED: RL UNIVERSAL,SPEEDSEAL TRACK ON AR-01 COMP SHINGLE-RLU 1Stary 2X6 RAFTERS 13'-9" 16° COMP,SEE DETAIL SNR-DC-00436 5'-4- 2'-1" 4'-0° 1 _10^ STAGGERED 1 S.L AG SCREWS UST. RL UNIVERSAL,SPEEDSEAL TRACK ON /16":2.5"MIN EMBEDMENT AR-02 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 17'-2" 16" COMP,SEE DETAIL SNR-DC-00436 51-4" 2--l' 4'-0" V-11011 STAGGERED TRUCTURAL NOTES: INSTALLERS SHALL NOTIFY -AR-01-SCALE:0.010417 ENGINEER OF ANY POTENTIAL D7-AR53° STRUCTURAL ISSUES PITCH:22° -{T-5" 11'-8" T-2" - OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. I IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG 10,-6" REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: 5'-4^TYP ••ALLOWABLE ATTACHMENT SPACING INDICATED ON 1'-4" PLANS TO BE REDUCED BY i 50% ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2 -SCALE:0.010417 S u n r u n AZIM:M:153 153° PITCH:22° 2'-6- 1V-8" —6-11-1—5'-10-— }-11" 00825-ME 3'4" I O P.. rft0 BOSb.—I 110. WE5iBI1Rl.NY f 1680 � FA%B°6T683883 2'-5" CUSTOMER RESIDENCE: 0 SUSAN STUART 900 BEACHWOOD LN, SOUTHOLD,NY,11971 17'-6" TE_L.(401)580-7841 _ - -- - -- - — - - - - --_- - 14' -- - - - APN:1000-070-00-10-00-058-000 PROJECT NUMBER: OF NEt1. 2168-900STUA Y B 0 - 5'-4"TYP - Q K.Z40, 0p� DESIGNER: (415)580-6920 ex3 t a ae9 t NICHOLAS LIVELY 7"1 r_ o w SHEET T-3"—d Poo '?,oz �i� LAYOUT AROFESSI,ONP� REV:B 2/1/2023 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE NOTE:TOTAL PV BACKFEED=53A OMETER#: USED FOR INTERCONNECTION M PSEGL196368304 CALCULATIONS UTILITY ACCOUNT#: GRID 9633605402 SUPPLY SIDE TAP 4 (N)LOCKABLE B C 1 EXISTINGBLADE TYPE MAIN BREAKER ( )N LOCKABLE SOLAREDGE TE HNOLOGIES: FUSED AC 1 DISCONNECT I BLADE TYPE SE10000H-USSN AC DISCONNECT 10000 WATT INV RTER JUNCTION BOX PV MODULES OR EQUIVALENT 3 3 2 1 VIKRAM SOLAR:VSMDHT.60.370.05 EXISTING _ / (31)MODULES 200A MAIN o.�. o��, `r + j// OPTIMIZERS WIRED IN: PANEL v — `i' (1)SERIES OF(16)OPTIMIZERS FACILITY 60A FUSES (1)SERIES OF(15)OPTIMIZERS LOADS GRDSQUARE D SQUARED LOAD RATED DC ISCONNECT D222NRB DU222RB WITH AFCI,RAPI SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A 3R,60A,2P COMPLIANT P401 120/240VAC 120/240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER s u n ru n 2 1"PVC OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 1"PVC OR EQUIV. (2)6 AWG THHNrrHWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHNITHWN-2 00825-ME tTT GNTI EROCKft�RO,WESIHURY,NY 11690 4 1"PVC OR EQUIV. (2)6 AWG THHN/THWN-2 (1)B AWG THHNrrHWN-2 (1)8 AWG THHN/THWN-2 -E-- F-P- CUSTOMER RESIDENCE: SUSAN STUART 900 BEACHWOOD LN, SOUTHOLD,NY,11971 MODULE CHARACTERISTICS TEL.(401)580-7841 VIKRAM SOLAR:VSMDHT.60.370.05: 370W APN:1000-070-00-10-00-058-000 OPEN CIRCUIT VOLTAGE: 41.1 V PROJECT NUMBER: MAX POWER VOLTAGE: 34.9 V 216R-900STUA SHORT CIRCUIT CURRENT: 12.71 A DESIGNER: (415)580-6920 ex3 B3 NICHOLAS LIVELY SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 11470 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 16V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:B 2/1/2023 SYSTEM OPERATING CURRENT: 28.67 A SYSTEM SHORT CIRCUIT CURRENT: 30A PAGE PV-4.0 solar=@@ Single Phase Inverter with HD Wave Technology for North America SE300OH-US/ SE380OH-US SE500OH-US/ SE600OH-US/ SE760OH-US SE10000H-US/SE1140OH-US I - SE300OH-US E380OH-US I SE -US I SE600.OH-US SE760OH-US !_SE100DOH-US SE11400H-US_L-- OUTPUT 3800 @_i4_0V 5000 6000 @ 240V 7600 VA Rated AC Power Output 3000 10000 11400 5 00 .......... .......... ...............•........ ..... .......... . ......I........ q...q.?9AY. ............ .......... ................ Max.AC Power Output 3000 3800 @ 240V f 6000 @ 240V 5000 7600 10000 114?0VA ......... . 208V 5000(�8,?08V ..... ....... 'W 66ip'��V61i�je''Mi'n'.-'Nom.-Max.' " i,*.... .... ........ . . ......1 / Vac ............... .............. ...... ..... ................ .... .......... ............... ................ ........ AC Output Voltage Min.-Nom.-Max. I ! V V ✓ V Vac X211„240,;264) ................... ....... ....... ...... ...... ......... ................ ...............l................ ................ . ........... AC Fre uenc Nominal 59.3-60-60.54) Hz Maximum Continuous Output Current 16 24 .......................... ....... A ........... . ........ .......... ..... ......... ................ ......... ...... ........ ............ ........... ....... Maximum Continuous Output Current240V 16 21 25 32 12.1 42 47.5 A ..........­........I...... . ........ ......... ......... ............. ................ ................ .... .,GFDI Threshold i Utility Monitoring,''I*sl'a"n'd'i*n'g"P'r'o,t*e,c*t,i,o*n,,,, ­............. .............*...... ........ Country Configurable Thresholds Yes INPUT - 11800 E50� Maximum DC Power @2 7756 _T_ 9300 W j�qy 4650 5900 1 ............ ...... ....... .............. ........J....J7650 Maximum@208V I 5100 1 ........ ................ ................ ...... .. ....­...*....... ......... Transformer-less,Un rounded ...... .......... .......... ........ ...... . .............. '�iaxim.um.In.py�,yRltag�e .......Nominal....... I-----*111­"111111-_ii6_................... ..... ........ ........ . ....... .... ...... ... ....... 400Vdc ... ... ..... Maximum.Input.Current.2.08Y......... ...... .. .......... ................ 20 27 _...30.5 I A c ..M��imum.lnput Current @240V 8.5 10.5...... 13.5.. 16.'5...... ..... .................... Max.In ut Short Circuit Current 45Adc ......... ... .. .. ..ReKE!rs�e-?olarity.Protection.........I.... ..... ...........I..................Yes,........I.........I.................. ................. ........... Ground-Fault Isolation Detect on ........ ....................... ........ ................600kta Sensitivity............I........... ................... .Maximum Inverter Efficiency ? .......... ......... .......... .... .. rtn .. "....9..9.......I...........................I......1.11.......... CEC Weighted.EfficlenRy.............. ...............................I...................... ............. .................. Nighttime'Power'Consumption <2.5 W ADDITIONAL FEATURES SyRqqqed CqTTy!jica.tiofl.Interfaces... ........ ...................R.S4.8S,,.E.t.h.ern.e,t, ............ .......... ...... ........... .. .. .... ... qlAk Data, ....... .................... .......... .....................9p 9 Revenue na 1(2) Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safet ............................... .� UL1741,UL1741 SA UL1699B,CSA C22.2,Canadian AFCi according t T.I.L.M-07 . ............................... ............................. .............. .......................... ........... ..Grid Connection StandardsIEEE1547,Rule 21,Rule 14 ............. ................... ............ Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Ranke.... ..I.............. 3/4"minimum./14-6 AWG 3/4"minimum/14-4 ... ........... ... . . . ...... ... .. DC Input Conduit Size/#of Strings 3/4' minimum 1-2 strings 14-6 AWG AWG Rang? 3/4 minimum 1-3 strings .............................. ..................... ....................................... ....... ............14.-6 AM........... ........... 21.3 x 14.6 x 7.3 1540 x 370 Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 x 185 mrn ­ . . .. ...... ... Weight.w.with.Safety.Switch.I....... ........ ...... 2.2. 10... 5 ........26.2 1.I..9.......... ....... ....... . ...... 38.8/17.6 lb <50dBA ...... Noise <25 ... Cooling......... ............. Natural Convec on Natural convection .......... ........... ............ ..qpq�n&:Temperature Range +140/- . . .(').(.-4.0'F./.-.40:qgp��RQ)(4).... T ....................... .............. ............ ......!�.t9 25to+60 ........... .. ... . ......... ......... Protection Rating ............................. ......... Safety h) ....I'*...**.......... with .................. ... ...... ....... .......... For other regional settings please contact SolarEdge support Revenue grade Inverter P/N:Sb000di-NOOONNC2 131 For power de-rating Information referto:https://www.solaredge.com/sltes/default/files/se-tempemture-demdng-note-na.pdf (4)-40 version PIN:SE)o=H-US000NNU4 ROMS 0 SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SiblarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All othertrademarks mentioned herein are trademarks of their respective owners.Date:07/2018/VOI/ENG NAM.Subjectito change without notice� f APPROVED AS NOTED USE 1 OCCUPANCY o DAT - • 3.20- S O p,LAWFU B. � �s� VVOTHOUT C L ABY OF pC ERTjF�r� ,� NOTIFY BUILDING DEPARTMENT AT �"�`�i��C�j� 631-765.1A02 BAM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1- FOUNDATION-'TWO REQUIRED FOR POURED CONCRETE 2 ROUGH-FRAMING&PLUMBING & INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE C w_a ,t 'L :� W' '~R A`L CODE- OF REQUIREMENTS OF THE CODES OF NEW �l�EW YORK STATE & TOWN CODES YORK STATE. NOT RESPONSIBLE FOR AS REQUIRED AND CONDITIONS OF DESIGN OR CONSTRUCTON ERRORS • SOUTHOLD TOWN ZBA ' SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES RETAIN STORM WATER RUNOFF N.Y.S.DEC PURSUANT TO CHAPTER 236 OF THE TOWN CODE. 7' lit weeYt�ciu.>ol�ecr�oN ® Astra v.1.699 August 11,2022 HCAT COA structural Subject:Structural Certification for Proposed Residential Solar Installation. ENGINEERS Job Number:216R-900STUA;Rev A Client:Susan Stuart Address:900 Beachwood Ln,Southold,NY,11971 Attn:To Whom It May Concern Afield observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun.Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: •2020 NEW YORK STATE RESIDENTIAL CODE WITH 2018 IRC/IBC/IEBC,7-16 ASCE&2018 NDS •Basic Wind Speed V=128 mph,Exposure C •Ground Snow Load=25 psf Based on this evaluation,I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally,I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summa Hardware Check Includes Uplift Check on Attachments/Fastener,Structure Check Considers Main Structure Orientation Attachment Spacing/Cantilever Configuration Max DCR Result Landscape 64/25 Staggered 59% Pass AR-01 Portrait 48/24 Staggered 77% Pass Roofing Material Pitch Structure Check Comp Shingle 22• E Pass Orientation Attachment Spacing/Cantilever Configuration Max DCR Result Landscape 64/25 Staggered 59% I Pass AR-02 Portrait 48/23 Staggered 77% f Pass Roofing Material Pitch Structure Check Comp Shingle 22• Pass DR [EC�0'V[E DD pF NElN 0 CT 1 1 2022 `-K. Z,40 0 :4 r 0 l-n, lY BiJMDING DEFT. It 1 31 f..; �i 197'w TOWN OF SOUTHOLD xP091365 ��._ A��FESS1 Paul Zacher,P.E. 1478 Stone Point Dr.Suite 190,Roseville,CA,95661 P (916)961-3960 Professional Engineer T: 916.961.3960 x101 E-mail:paul@pzse.com SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION SYSTEM SIZE:1156OW DC,10000W AC ALL WORK SHALL COMPLY WITH 2020 NEW YORK STATE RESIDENTIAL CODE SOLAR MODULES PV-1.0 COVER SHEET MODULES:(34)JA SOLAR:JAM60S10-3401MR WITH 2018 IRCABGIEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS SE SERVICE ENTRANCE INVERTERS:(1)SOLAREDGE TECHNOLOGIES: AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN SE1000OH-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, MP MAIN PANEL PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-4.0 ELECTRICAL PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT&SKIRT MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY- INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT FLUSH ATTIC VENT OF NEI1.y •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER El FLUSH Z O MODULES,ARE CLASS A FIRE RATED. 0 PVC PIPE VENT CO AcyF��� •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) 0 METAL PIPE VENT - D t 119'w ® T-VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). E � •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC (p SATELLITE DISH SSI AC DISCONNECT(S) p p 1365 a . i� �OFEONP •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC For Structural Only O DC DISCONNECT(S) FIRE SETBACKS •10.46 AMPS MODULE SHORT CIRCUIT CURRENT. •16.34 AMPS DERATED SHORT CIRCUIT CURRENT 1690.8(a)&690.8(b)]. CB IQ COMBINER BOX HARDSCAPE i— INTERIOR EQUIPMENT —PL— PROPERTY LINE L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION reen Of DC DIRECT CURRENT 00825-ME (E) EXISTING 15p LOMAVE HIIXWO W11801 West [)eying ESS ENERGY STORAGE SYSTEM c EXT EXTERIOR Shelter.ISI. INT INTERIOR CUSTOMER RESIDENCE: Heighfs MAG MAGNETIC SUSAN STUART MSP MAIN SERVICE PANEL 900 BEACHWOOD LN, (N) NEW SOUTHOLD,NY,11971 -• NTS NOT TO SCALE OC ON CENTER TEL.(401)580-7841 S11 PRE-FAB PRE-FABRICATED APN:1000-070-00-10-00-058-000 Southold PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: PV PHOTOVOLTAIC 2161-900STUA RSD RAPID SHUTDOWN DEVICE �OO Beachwood TL TRANSFORMERLESS DESIGNER: (415)58M920 ex3 ♦+Ln;Southold,NY..: ti;facies E v P VOLTS NICHOLAS LIVELY W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:A 8/12/2022 PAGE PV-1.0 ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=1116"=V-0" SITE PLAN DETAIL-SCALE=1/64"=V-0" PITCH AZIM AZIM (SQFT) ® Vil AR-01 22" 153° 165" 108.6 GN�OOO AR-02 22° 153° 165° 507 9� (E)RESIDENCE g g ACCESS ROOF (E)DETACHED STRUCTURE '2 Y o' FIRE SETBACKS (18"TYP) (N)ARRAY AR-01 (N)ARRAY AR-02 sunrun aroBEss I65 BUSH ST,Slllf E 1100 MID ] su Fwwcrsco.ueala v.BlBaesmsa 00825-ME SE 0 INV 1504RLOREAV�XIOCSYSIE NY 11W1 PHONE 805 S105a8i FA%84426B.NT! CUSTOMER RESIDENCE: SUSAN STUART _ 900 BEACHWOOD LN, SOUTHOLD,NY,11971 • TEL.(401)580.7841 APN:1000-070-00-10-00-05&000 OF NS PROJECT NUMBER: K.ZgC,y�0 216R-900STUA h P i i0 d L i� DESIGNER: (415)580-6920 eu3 F c 6 } 4 119 Lu NICHOLAS LIVELY apRo1365, SHEET SITE PLAN FESSION For Structural Only REV:A 8/12/2022 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ONWIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 13-91, 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 128 MPH 3-SEC GUST. S.S.LAG SCREWS: RL UNIVERSAL,SPEEDSEAL TRACK ON 5/16":2.5"MIN EMBEDMENT AR-02 COMP SHINGLE-RLU 1Story 2X8 RAFTERS 1T-2" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" I.-Ill. STAGGERED STRUCTURAL NOTES: INSTALLERS SHALL NOTIFY D1-AR-01-SCALE,1/8"=1'-0" ENGINEER OF ANY POTENTIAL AZIM:153° STRUCTURAL ISSUES PITCH:22° OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. IF ARRAY(EXCLUDING SKIRT) 4'-3" IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS fit FOLLOWS: ••ALLOWABLE ATTACHMENT SPACING INDICATED ON 11" PLANS TO BE REDUCED BY 50 - 11'-2" —5'-10"— ..ALLOWABLE OVERHANG V-2" INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:1/8"=1'-0" AZI M:153° s u n ru n PITCH:22° 10" 00825-ME S-41" O I 15CNARLOTfEAVE,NCKS/LLE NY 11B01 PHONE BO151QSd8] 6-811 _} FAX B0.S3681@3 2-3CUSTOMER RESIDENCE: SUSAN STUART - 5'4'TYP - 900 BEACHWOOD LN, SOUTHOLD,NY,11971 13'-3" TEL.(401)580-7841 APN:1000-070-00.10-00-058-000 OF NS PROJECT NUMBER: �K'ZgC,y�p0.p� 216R-900STUA O *,r) ,d L i# DESIGNER: (415)5805920 ex3 1'S" c " t 119 w NICHOLAS LIVELY -�T-7" P091360e2' SHEET TF�� 39'-2" Lr-1„ SSIONA� LAYOUT REV:A 8/12/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE NOTE:TOTAL PV BACKFEED=53A OMETER#: USED FOR INTERCONNECTION M PSEGLI96368304 CALCULATIONS UTILITY ACCOUNT#: GRID 9633605402 SUPPLY SIDE TAP 4 \+ EXISTING 200A (N)LOCKABLE SOLAREDGE TECHNOLOGIES: MAIN BREAKER BLADE TYPEFUSED AC (N)LOCKABLE SE10000H-USSN WITH DISCONNECT BLADE TYPE REVENUE GRADE METERING 1 AC DISCONNECT 10000 WATT INVERTER JUNCTION BOX PV MODULES 3 3 2 oR EQUIVALENT 1 JA SOLAR:JAM60S10-340/MR EXISTING / (34)MODULES 200A MAIN ±�f! OPTIMIZERS)TER OF IR PANEL PTIMIZERS —___ FACILITY 60A FUSES (1)SERIES OF(17)OPTIMIZERS LOADS _GROUND SQUARE D SQUARE D LOAD RATED DC DISCONNECT D222NRB DU222RB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A 3R,60A,2P COMPLIANT P401 120/240VAC 1201240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER s u n r u n 2 1"PVC OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 1"PVC OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 00825-ME 4 1"PVC OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHNrrHWN-2 (1)8 AWG THHNITHWN-2 I-E HG SY¢LE rvY ttBOf FR%Bi5]693fR2 CUSTOMER RESIDENCE: SUSAN STUART 900 BEACHWOOD LN, SOUTHOLD,NY,11971 MODULE CHARACTERISTICS MINP401 TEL.(401)580-7841 OPTIMIZER CHARACTERISTICS: JA SOLAR:JAM60S10-340/MR: 340 W MIN INPUT VOLTAGE: 8 VDC APN:1000-070-00.10-00-058-000 OPEN CIRCUIT VOLTAGE: 41.55 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX POWER VOLTAGE: 34.73 V MAX INPUT ISC: 11.75 ADC 216R-900STUA SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 NICHOLAS LIVELY SYSTEM SIZE: 11560 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 17V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 8/12/2022 SYSTEM OPERATING CURRENT: 28.9 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 WARNING ! INVERTERI WARN I NOG, NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE • PHOTOVOLTAIC SYSTEMPHOTOVOLTAIC DC DISCONNECT 110.21(8),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. - MAXIMUM SYSTEM VOLTAGE:COMBINER PANEL 480 • .SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINEAND LOAD DO NOT ADD LOADSWORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN MAXIMUM CIRCUIT CURRENT:I ADC •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING (ABEL LOCATION: • • METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION PHOTOVOLTAIC AC COMBINER(IF •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT APPLICABLE). • _�• OR DC-TO-DC C• D 15 ADC INVOLVED. •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535,4-2011,PRODUCT SAFETY LABEL LOCATION: PER CODE(S):CEC 2019:705.12(B)(2)(3)(cj, SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEACIDC (IS APPLICABLE). NEC 2017:705.12(B)(2)(3)(c) LABEL LOCATION: •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). PER CODE(S):CEC 2019:690.13(B),NEC PER CODE(S):CEC 2019:690.53,NEC 2017:690.53 2017:690.13(8) ! WARNING WARNING DUALPOWERSUPPLY Y7 SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE SYSTEM LABEL LOCATION: LABEL LOCATION: ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S):CEC 2019: PER CODE(S):CEC 2019:705.12(8)(3),NEC 705.12(6)(2)(3)(6),NEC 2017: 2017:705.12(B)(3) . 705.12(B)(2)(3)(b) FOR , ■ PV SYSTEM LABEL LOCATION: BUILDING SUPPLIED BY UTILITY INSTALLED WITHIN TOF RAPID SHUT DOWN GRID AND PHOTOVOLTAIC SWITCH PER CODE(S):CEC 2019:690.56(C)(3),NEC 2017:.3.CFC 01 :124.6.3sos.11.1,IFczats: SYSTEM sunrun 1204.5.3,CFC 2019:1204.5.3 4„ SOLAR PV SYSTEM EQUIPPED 00825-ME WARNING: PHOTOVOLTAIC • • / WITH RAPID SHUTDOWN ® FN BIi 6B AVE NCKS ILEI 111 PHOf1E d"6510514I POWER . ■ • ■ CUSTOMER RESIDENCE: SUSAN STUART LABEL LOCATION: 900 BEACHWOOD LN, INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, PV SYSTEM SOUTHOLD,NY,11971 AT EACH TURN,ABOVE AND BELOW PENETRATIONS, 3„ TURN RAPID SHUTDOWN DISCONNECT ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SWITCH TO THE"OFF" TEL.(401)580.7841 PER CODE(S):CEC 2019:690.31(G)(3),690.31(G)(4), POSITION TO SHUT DOWN r NEC 2017:690.31(G)(3),690.31(G)(4)IFC 2012: APN:1000.070.00.10.00-058-000 605.11.1.4 PV SYSTEM AND REDUCE SHOCK HAZARD IN THE PROJECT NUMBER: ARRAY 216R-900STUA PHOTOVOLTAIC • • LABEL LOCATION. OPERATING POINT OF INTERCONNECTION DESIGNER: (415)580-6920 ex3 MAXIMUM AC 67 AMPS (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) NICHOLAS LIVELY NOMINAL OPERATING _ - VOLTAGE: LABELLOCATION: LABELLOCATION: SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):CEC 2019:690.54,NEC 2017:690.54 ARE CONNECTED. PER CODE(S):CEC 2019:690.56(C)(1)(a),NEC 2017: REV:A 8/12/2022 690.56(C)(1)(a) PAGE PV-5.0 a Harvest the Sunshine 340W MBB Half-Cell Module � • • JAM60S10 320-340/MRSerie Higher output power Lower LCOE Less shading and lower resistive loss Better mechanical loading tolerance Introduction Assembled with multi-busbar PERC cells,the half-cell configuration of the modules offers the ' i advantages of higher power output, better temperature-dependent performance, reduced I shading effect on the energy generation,lower risk of hot spot,as well as enhanced tolerance _ for mechanical loading.. - •e r 1. Comprehensive Certificates productf UL 61215,UL 61730 o 25-year linear power output warranty ISO 9001:2015 Quality management systems • 14001:2015 Environmental management systems F7 5-9/6 OHSAS2007 18001: Occupational ment systems 90% IEC TS 62941: 2016 Terrestrial photovoltaic(PV)modules- 80% Guidelinesfor -. confidencemodule design 5 j0 15 20 28 year 13 JA Linear Power Warranty m Industry Warranty AR& 3 i'r� J/-�SOLAR wwwjasolaccom _•+ Specifications subject to technical changes and tests:. �+�' JASolar reserves the rightof final'interpretation, ❑ •o:' JASOLAR JAM60S 10 320-340/M R MECHANICAL DIAGRAMS SPECIFICATIONS 99652 31:1 Cell Mono Weight 18.7kg±3% Dimensions 1689±2mmx996±2mmx35±lmm Enlarge view of mountma hole(0:1) Cable Cross Section Size 4mm' (12AWG) Grounding holes 10 places No.of cells 120(6x20) ilia IO o O+ um�s,mm Junction Box IP68,3 diodes Mounting holes AA Connector QC 4.10 (1000V) 8 places QC 4.10-35 (1500V) Label Cable Length Portrait:300mm(+)1400mm(-); erelnie9 holes [Ell (Including Connector) Landscape:1000mnri 000mm(-) e pWces Packaging Configuration 30 Per Pallet Remark:customized frame color and cable length available upon request ELECTRICAL PARAMETERS AT STC JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 TYPE -320/MR -3_25/MR -330/MR_ -3.35/MR -340/MR Rated Maximum Power(Pmax)[W] 320 325 330 335 340 Open Circuit Voltage(Voc)[V] 40.60 40.87 41.08 41.32 41.55 Maximum Power Voltage(Vmp)[V] 33.73 33.97 34.24 34.46 34.73 Short Circuit Current(Isc)[A] 10.16 10.23 10.30 10.38 10.46 Maximum Power Current(Imp)[A] 9.49 9.57 9.64 9.72 9.79 Module Efficiency[%] 19.0 19.3 19.6 19.9 20.2 r - Power Tolerance 0-+5W Temperature Coefficient of Isc(a_Isc) +0.044%/°C Temperature Coefficient of Voc([i_Voc) -0.272%/`C Temperature Coefficient of Pmax(y_Pmp) -0.350%/'C STC Irradiance 1000W/ml, cell temperature 25°C,AM1.5G Remark:Electrical data in this catalog do not refer to a single module and they are not part of the offer.They only serve for comparison among different module types. ELECTRICAL PARAMETERS AT NOCT OPERATING CONDITIONS TYPE JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 320/MR -325/MR -330/MR -335/MR -340/MR Maximum System Voltage 1000Vl1500V DC(UL) Rated Max Power(Pmax)[W] 241 245 249 253 257 Operating Temperature -40°C-+85°C Open Circuit Voltage(Voc)[V] 38.05 38.26 38.46 38.68 38.90 Maximum Series Fuse 20A Max Power Voltage(Vmp)M 31.58 31.80 32.02 32.21 32.40 Maximum Static Load,Front 5400Pa(112 Ib/ft') Short Circuit Current(Isc)[A] 8.07 8.14 8.21 8.28 8.35 Maximum Static Load,Back 2400Pa(50 Ib/ft2) Max Power Current(Imp)[A] 7.63 7.70 7.78 7.85 7.93 NOCT 45±2°C NOCT Irradiance 800W/m?,ambient temperature 20°C Fire Performance Type 1 wind speed 1m/s,AM1.513 CHARACTERISTICS Current-Voltage Curve JAM60S10-335/MR Power-Voltage Curve JAM60S1O-335/MR Current-Voltage Curve JAM60S10-335/MR 350 10 -y000W/m"'-- --- 1000W/m' 10 -_10°C __ ._ 300 'eUUW/m�___-__-_____ --25•C__ -600W/rrP - 8 -tlUOPV/m'-_____-_.__ 250 -__ - _.- _ a 400W%m' Q -_55°C _ _- E 6 -600W/m'_- - - 200 -_2(10W/rr?- -- _ - c 6 ___70°C_- _ d d ;0 150 U 4 400W/m' 0_ U 4 -- -- __.______-__--_ 100 2 200 m _ - _ 50 - _ _ _ 2 ----_.__________ 0 0 10 20 30 40 0 0 10 20 30 40 0 0 10 23 30 40 Voltage(V) Voltage(V) Voltage(V) Premium Cells Premium Modules 1 1 Sola =es • Single Phase Inverter with HD-Wave Technology • for North America = SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE7600H-US/SE1000OH-US/SE1140OH-US - - solar ME 44D.- G' solar••.- ��pvarfe�=p 4:�1 af.o Yea�Y o� •' e • 9 - ' - O fj IK I Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small { — High reliability without any electrolytic capacitors q Built-in module-level monitoring 11111111111`,A�� d Outdoor and indoor installation Y,/a`/e � Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) + I www.solaredge.us so I a r " • • Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/ SE380OH-US/ SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US/SE1140OH-US SE3000H-US SE380OH-US I SE5000H-US SE6000H-US SE760OH-US SE30000H-US I SE1140OH-US OUTPUT Rated AC Power Output 3000 3800@ 240V 5000 6000 @ 240V 7600 10000 11400 VA .............................................. ................ 3300,E?l. 5000 ............... . ..... .208y, ................ ................. ................. ........... • Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA ............................................ ................ 3300,�u 208V. 5000.P,208y AC Output Voltage Min:Nom:Max. ✓ - _ - Vac X183.-208 229)........................... ............... ................ ................ ................. ................ ................. ................. ........... AC Output Voltage Min.-Nom.-Max. ,/ ✓ Vac (211.-240-264)........................... ................ . ............... ................ ................. ................ ................. ................. ........... AC Frequency(Nominal) 59.3:60:60SI'I Hz .................. ................ ................ . ............... ................. ................. ........... Maximum Continuous Output Current 16 24 A 208V....................................... ................ ................ ................ ................. ................ ................. ................. ........... Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A @240V.................................... ................ ................ ................ ................. ................ ................. ................. ........... GFDI Threshold 1 A ................................... ........................................................... .................................... Utility Monitoring,Islanding Protection, yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W . ..... ................ ........9 ...... ................ ................. ................. ........... Maximum DC Power @208V 5100 7750 - .............................................. ................ ................ ................ ................. ................ ................. ................. ........... Transformer-less Un rounded ............................ ...... Yes Maximum Input Voltage 480 Vdc . .................................................... . Nominal DC Input Voltage 380 400 Vdc .... ..... ..... . .. ......... . ................ ................. ................ ................. ................. ........... Maximum Input Current 208V............ .......:........ .......9.......I...... I 13.5 .......... ................. ...... .. ..... ... rr .............. ......... ....... ........... Maximum Input Cuent @240V 8.5 10.5 13.5 16.5 20.. 27 30.5 Adc ... ........... Max.Input Short Circuit Current 45 Adc ........ . ........................... .................. ........................................................... . Reverse-Polarit Protection Yes ........y........................... .......................................................... ........... Ground-Fault Isolation Detection 600ks Sensitivity .......................................... ................ ....... Maximum Inverter Efficienc 99 99.2 ......................rn............. ................ ........................................................................................................ ........... CECWeighted Efficiency................... ...........................................................99 ..... ...................................... Nighttime Power Consumption 1 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485;Ethernet,ZigBee(optional),Cellular Soptional) Revenue Grade Data,ANSIC12.20,,,,,, Opttona.......................................................... Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741i UL17415A,UL1699B,CSA C22.2,Canadian AFCI according.to T.I,L.M.07 ...... ...................................... ................ Grid Connection Standards IEEE 547 Rule 21,Rule 14(HI) .............................................. . .......... Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4"minimum/14.6 AWG 3/4"minimum/144 AWG DC Input Conduit Size/k of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/ AWG Range............................... .................... . 14;6 AWG............ ...........21.3x14.6x7.3/540x370 Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 in/mm x 185 Weight with Safety Switch.............. ...........?2/.10.............I..25.1/11:4..I...........26.2/11.9........... ....... .38:8./,17:6..... Ib/kg Noise <25 <50 deA ........................................... .................................................................... .................................................... ........... Cooling . .........Natural Convection .............. Natural convection Operatin�TemperatureRange 13 to+140/:25to+60 �:40F/.40Coption) •F/•C aI ° Protection Rating NEMA 3R(Inverter with Safety Switch) For other regional settings please contact SolarEdge support OI Revenue grade inverter P/N:Hmn H-USOOONNQ i'i For power de-rating Information refer to:https://www.solaredge.com/sites/default/tiles/se-temperature-derating-note-na.pdf -40 version P/N:SExx H-USOOONNU4 'I 1 rFrom FRo H S o SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE, logo,OPTIMIZED are trademarks or registered trademarks larEdge Tecbnolog�ies,Inc.All other trademarks mentioned herein rDate:r r r I/ENG NAM.Subject to change without notice.I REvCAT 4 February 1,2023 CAT 4 structural Subject:Structural Certification for Proposed Residential Solar Installation. ENGINEERS Job Number:216R-900STUA;Rev B Client:Susan Stuart Address:900 Beachwood Ln,Southold,NY,11971 Attn:To Whom It May Concern Afield observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun.Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: •2020 NEW YORK STATE RESIDENTIAL CODE WITH 2018 IRC/IBC/IEBC,7-16 ASCE&2018 NDS •Basic Wind Speed V=128 mph,Exposure B •Ground Snow Load=25 psf Based on this evaluation,I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally,I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summa Hardware Check Includes Uplift Check on Attachments/Fastener,Structure Check Considers Main Structure Orientation Attachment Spacing/Cantilever Configuration Max DCR Result Landscape 64/25 Staggered 62% Pass AR-01 Portrait 48/22 Staggered 92% Pass Roofing Material Pitch Structure Check Comp Shingle 22• Pass Orientation Attachment Spacing/Cantilever Configuration Max OCR Result Landscape 64125 Staggered 55% Pass AR-02 Portrait 48/24 Staggered 82% Pass Roofing Material Pitch Structure Check Comp Shingle 22• Pass pF NE�NY Paul Zacher,P.E. K. Z,q O Professional Engineer T: 916.961.3960 x101 email: paul@pzse.com w � xP�91365�2 �� AR��ssioNP�, 02/02/2023 1478 Stone Point Dr.Suite 190,Roseville,CA,95661 P (916)961-3960 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION SYSTEM SIZE:11470W DC,t000OW AC ALL WORK SHALL COMPLY WITH 2020 NEW YORK STATE RESIDENTIAL CODE SOLAR MODULES MODULES:(31)VIKRAM SOLAR:VSMDHT.60.370.05 WITH 2018 IRC/IBC/IEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS SE SERVICE ENTRANCE PV-1.0 COVER SHEET INVERTERS:(1)SOLAREDGE TECHNOLOGIES: AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN SE1000OH-USSN PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. MAIN PANEL PV-3.0 LAYOUT MP SEE DETAIL SNR-DC-00436 PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-4.0 ELECTRICAL GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE IILC PV LOAD CENTER MODULES,ARE CLASS A FIRE RATED. DX CHIMNEY RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). — SUNRUN METER CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). 0 ATTIC VENT ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 12.71 AMPS MODULE SHORT CIRCUIT CURRENT. PM DEDICATED PV METER FLUSH ATTIC VENT 19.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)). o PVC PIPE VENT INV INVERTER(S) 0 METAL PIPE VENT AB ® T-VENT AC DISCONNECT(S) OF NE Iy AI? SATELLITE DISH K.ZqC Y0 CO ODC DISCONNECT(S) ® FIRE SETBACKS ; L 1 9 Of CB IQ COMBINER BOX HARDSCAPE 1366, I——1 INTERIOR EQUIPMENT —PL— PROPERTY LINE pRpFESSIONP� L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION 00825-ME reen[70Ci DC DIRECT CURRENT (E) EXISTING 11l LPM RGUE ROCK RORO,WESiBUW,W 11590 D e ri Ii PHONE W-0..., a far: West 9 ESS ENERGY STORAGE SYSTEM FMU51883 EXT EXTERIOR Shelter Isk INT INTERIOR CUSTOMER RESIDENCE: Heights MAG MAGNETIC SUSAN STUART 25 MSP MAIN SERVICE PANEL 900 BEACHWOOD LN, (N) NEW SOUTHOLD,NY,11971 NTS NOT TO SCALE OC ON CENTER TEL.(401)580-7841 i r _,f sil PRE-FAB PRE-FABRICATED APN:1000-070-00-10-00-058-000 SOUtfiOld PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC PROJECT NUMBER: ii RSD RAPID SHUTDOWN DEVICE 216R-900STUA goo..Beachwood TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 x �Ln,'SOUhlOId,'NY... %liades•E V P TYPICAL NICHOLAS LIVELY VOLTW WATTS SHEET REV NAME DATE COMMENTS COVER SHEET B C.HALES 2/1/2023 MOD SWAP REV:B 2/1/2023 PAGE PV-1.0 ARRAY TRUE PV AREA SITE PLAN-SCALE=0'-01/16"=1'-0" SITE PLAN DETAIL-SCALE=0'-01/64"=V-0" PITCH AZIM (SOFT) AR-01 1 22° 1 153° 119.8 001D W-2 22° 153° 499 t':.. (E)RESIDENCE ACCESS ROOF (E)DETACHED STRUCTURE 4 A O ° PL ° sk � NOTES: FIRE SETBACKS RESIDENCE DOES NOT CONTAIN ACTIVE FIRE (18-TYP) SPRINKLERS. (N)ARRAY AR-01 (N ARRAY AR-02 s u n r u n ARRAY DETAILS: • TOTAL ROOF SURFACE AREA:2300 SOFT. ER°NME DBEs: r AC-1us.ms],sunE 1600 • TOTAL PV ARRAY AREA 618.8 SO FT. sn]1FRwcaco,uwlol MP • PERCENTAGE PV COVERAGE: '918'6t091 (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE 00825-ME SE 0 INV AREA) 100=26.9% 1]]CNiTNGUEROCK RORD,WESTBURY,NY 11590 P-- FMA%815]88— CUSTOMER RESIDENCE: SUSAN STUART 900 BEACHWOOD LN, SOUTHOLD,NY,11971 TEL.(401)580-7841 APN:1000-070-00-10-00-058-000 PROJECT NUMBER: OF NEl1. 216R-0OOSTUA K•ZgCy�p� DESIGNER: (415)580.6920 ex3 NICHOLAS LIVELY - w SHEET SITE PLAN p P�91365. V� ROFESSIONP REV:B 2/1/2023 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:" AR-01 COMP SHINGLE-RLU 11-Story 2X6 RAFTERS 13'-9" 16° COMP,SEE DETAIL SNR-DC-00436 5'-4- 2'-1" 4'-01'-10" STAGGERED 128 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 1-Story 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" STAGGERED /16":2.5"MIN EMBEDMENT 2X8 RAFTERS 17'-2" COMP,SEE DETAIL SNR-DC-00436 1'-10° STRUCTURAL NOTES: INSTALLERS SHALL NOTIFY D7-AR-01-SCALE:0.010417 ENGINEER OF ANY POTENTIAL AZIM:153' STRUCTURAL ISSUES PITCH:22° -}T-5° 11'5" 3'-2" - OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. I I IF ARRAY(EXCLUDING SKIRT) 3' 3'-1" IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG 10,-0" REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: - 5'-4"TYP ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY B 50% ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:0.010417 AZIM * 23'-0" PITC 22 H:22° s u n r u n PITC {— 11'-0" —5'-11"—.'-5'-10"—. }-11" I I I 00825-ME 3'�° I O i]]G GUE ROCK ROM.W TRURY,NY 11= PHONE 805510.518] � FN(815]8810Y2 2 S° CUSTOMER RESIDENCE: O SUSAN STUART 900 BEACHWOOD LN, SOUTHOLD,NY,11971 17'-6° TEL.(401)580-7841 14' APN:1000-070-00-10-00-058-0DO PROJECT NUMBER: 8 IF OF NE(y 216R-900STUA B O - V-4"TYP - y K'Z-4C,� DESIGNER: (415)580-0920 ex3 NICHOLAS LIVELY 7"J r e of T-3" P2uj� SHEET - -} LAYOUT 091365- QOFESSI ONP REV:B 2/1/2023 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE NOTE:TOTAL PV BACKFEED=53A OMETER M USED FOR INTERCONNECTION M PSEGLI96368304 CALCULATIONS UTILITY ACCOUNT M GRID 9633605402 SUPPLY SIDE TAP 4 (N)LOCKABLE C EXISTING 200A BLADE TYPE A]B� MAIN BREAKER FUSED AC (N)LOCKABLE SOLAREDGE TEFRTERJUNCTION DISCONNECT BLADE TYPE SE1000OH-USSN 1 AC DISCONNECT 10000 WATT INV PV MODULES OR EQUIVALENT 3 3 2 1 VIKRAM SOLAR:VSMDHT.60.370.05 EXISTING / (31)MODULES 200A MAIN ®. oho `r ±�// �)SER�ES OF(16)OPTIMIZERS PANEL FACILITY [60:A:FSES (1)SERIES OF(15)OPTIMIZERS LOADS GROUND o SQUARE D SQUARED LOAD RATED DC ISCONNECT D222NRB DU222RB WITH AFCI,RAPI SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A 3R,60A,2P COMPLIANT P401 1201240VAC 120/240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER s u n ru n 2 1"PVC OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 1"PVC OR EQUIV. (2)6 AWG THHN/fHWN-2 (1)10 AWG THHNrrHWN-2 (1)8 AWG THHN/THWN-2 00825-ME 4 1"PVC OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 now wouEno«rsono,wEsreuar.Nr++55o PHONE 000310.5101 FM- CUSTOMER RESIDENCE: SUSAN STUART 900 BEACHWOOD LN, SOUTHOLD,NY,11971 MODULE CHARACTERISTICS TEL.(401)580-7841 VIKRAM SOLAR:VSMDHT.60.370.05: 370 W APN:1000-070-00-10-00-058-000 OPEN CIRCUIT VOLTAGE: 41.1 V PROJECT NUMBER: MAX POWER VOLTAGE: 34.9 V 216R-900STUA SHORT CIRCUIT CURRENT: 12.71 A ADESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 NICHOLAS LIVELY SYSTEM SIZE: 11470 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 16V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:B 2!1/2023 SYSTEM OPERATING CURRENT: 28.67 A SYSTEM SHORT CIRCUIT CURRENT: 30A PAGE PV-4.0 �QI WARN'IN V ,1WARN IN G INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE PHOTOVOLTAIC SYSTEMPHOTOVOLTAIC DC DISCONNECT 11021(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690.OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. COMBINER PANELMAXIMUM SYSTEM VOLTAGE: 460VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOADDO NOT ADD LOADS WORDS,COLORS AND SYMBOLS. MAXIMUM 30 .LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING THE OPEN POSITION LABEL LOCATION: • • SIDES MAY BE EVER IN METHOD AND SHALL NOT BE HAND WRITTEN. ON PHOTOVOLTAIC AC COMBINER(IF •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT APPLICABLE). CONTROLLER••DC-TO-DC CONVERTER15ADC •SIG S AND LABELS SHALL COMPLY WITH ANSI Z535A-2011,PRODUCT SAFETY LABEL LOCATION: PER C017:70:CEC 2019:705.12(B)(2)(3j(t), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINE, PANEAC/DC(IF NEC 2017:705.12(B)(2)(3)(c) LABEL LOCATION: •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). PER CODE(S):CEC 2019:690.13(6)•NEC PER CODE(S):CEC 2019:69D.53,NEC 2017:690.53 2017:69D.13(B) rQ! WARNING m WARNING DUAL POWER SUPPLY POWER SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE SYSTEM LABEL LOCATION: LABEL LOCATION: ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S):CEC 2019: PER CODE(S):CEC 2019:705.12(B)(3),NEC 705.12(B)(2)(3)(b),NEC 2017: 2017:705.12(B)(3) 705.12(B)(2)(3)(b) FOR • L■ PV SYSTEM LABEL LOCATION: BUILDING SUPPLIED BY UTILITY INSTALLED WITHIN V OF RAPID SHUT DOWN GRID AND PHOTOVOLTAIC SWITCH PER CODE(S):CEC 2019:690.56(C)(3),NEC 2017:690.56(C)(3).IFC 2012:605.11.1,IFC 2016: SYSTEM s u n r u n 1204.5.3,CFC 2019:1204.5.3 4• SOLAR PV SYSTEM EQUIPPED 00825-ME WITH RAPID SHUTDOWN ® nt �EattxR�. a�a..NY" PHONE BOSSt0 87 ■• ■ • ■ CUSTOMER RESIDENCE:N w SUSAN STUART LABEL LOCATION: 900 BEACHWOOD LN, INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, PV SYSTEM AT EACH TURN,ABOVE AND BELOW PENETRATIONS, 3• TURN RAPID SHUTDOWN DISCONNECT SOUTHOLD,NY,11971 ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SWITCH TO THE"OFF" TEL.(401)580-7841 PER CODE(S):CEC 2019:690.31(G)(3),690.31(G)(4), POSITION TO SHUT DOWN NEC 2017:690.31(G)(3),690.31(G)(4)IFC 2012: APN:1000-070-00-10-00-058-000 605.11.1.4 PV SYSTEM AND REDUCE SHOCK HAZARD IN THE PROJECT NUMBER: BRAY, 2161R-900STUA PHOTOVOLTAIC ADISCONNECT LABEL LOCATION: MAXIMUM• OPERATING POINT OF INTERCONNECTION DESIGNER: (415)580-6920 ex3 NOMINAL OPERATING AC VOLTAGE: 240 VAG L (PER CODE:NEC690.56(B),NEC705.10,225.37.2302(E)) NICHOLAS LIVELY LABEL LOCATION: LABEL LOCATION: SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):CEC 2019:690.54•NEC 2017:690.54 ARE CONNECTED. PER CODE(S):CEC 2019:690.56(C)(1)(a),NEC 2017: REV:B 2/1/2023 690.56(C)(1)(a) PAGE PV-5.0 PREXOS SERIES 6 Monocrystalline Solar PV Modules, Bifacial, MBB, M6 Half-Cell, PREXOS VSMDHT.60.AAA.05 POWER OUTPUT WATT MAXIMUM EFFICIENCY% POSITIVE POWER TOLERANCE WP CELLS(HALF CUT) 340 - 375 20 . 22 0 -+4 .99 M6 120 EFFECTIVE GAIN OF 1% OF CELL ACTIVE AREA by using cylindrical tabbing wire _ -- Bypass diodes and innovative series- parallel connections enable the module to perform better in PARTIAL SHADOW CONDITIONS BETTER TOLERANCE TO MICRO CRACK � Higher number of busbar makes the PV 4.. modules less prone to loss in efficiency due to micro-cracks. lllllll IMPROVED FIELD RELIABILITY due to ME flu IN- - - -- = ------------- -- � multiple contact points on the cell. WA` SUPERIOR PRICE PERFORMANCE half-cut improves the output of the module without adding much to cost UP TO 15% POWER GAIN from ground facing side �� _ INCREASED SHADE TOLERANCE HALF-CELL MODULE Functions like two parallel __ _ modules,enabling the half-cell string to work in partial shading PTL OCE CERTIFIED APPLICATIONS • On-grid large scale • On-grid rooftop • Rooftop residential FRAME utility systems industrial and systems SILVER commercial systems BLACK BACKSHEET TRANS' WHITE o PARENT vikramsolar VSL/ENG/SC/267 I www.vikramsolarcom CREATING CLIMATE FOR CHANGE f • T E C H NI.C, QAT�A vikramsolar PREX®S SERIES1200E L� -r- MBB - CREATING CLIMATE FOR CHANGE THIS DATASHEET IS APPLICABLE FOR: PREXOS VSMDHT.60.AAA.05 (AAA=340-375)---_ Electrical Data 1,2 All data refers to STC IAM 1.5,1000 W/m',25°01 Dimensions in mm Peak Power Pmax(0-+4.99Wpl : 340: 345: 3501:, 355: 360: 365: 370: 375 Maximum Voltage Vm"(V) 34.5: 34.6: 34.6: 34.7: 34.71 34.8: 34.91 34.9 Maximum Current I,(A) 9.881 10.01: 10.13 10.27: 10.411 10.53 10.651 10.75 Open Circuit Voltage Vee(V) i 40.6: 40.7: 40.8: 40.8: 40.9: 41 41.1: 41.1 Short Circuit Current Ise(A) 10.9: 11.01 11.131:, 11.25: 11.351 11.45: 11.55: 11.65 UPG Module Efficiency q(%) : 18.34: 18.61: 18.88: 19.14: 19.41: 19.68: 19.95: 20.22 115TG1000W/mlirradiance,25"Ccea1empemtum,AM1.5g spectrumaccordmg to EN 60904.3.121 Powermeas,mmentu,mtaintyiswithin+/-2%. r - Electrical Parameters at NOCT3 IaNCMNaOM Power(W) 251.6: 255.3: 259 262.7: 266.4: 270.1 273.8: 277.5 V@Pm„IV) : 31.9: 32 i 32 32.1 1 32.1 32.2: 32.2: 32.2 @P.-(A) 7.9' 8.01: 8.1 8.22 8.33' 8.42:1 8.52: 8.6 w u cRa Vee IV) : 37.9 38 1 38.1 38.1: 38.2 38.3 38.4 38.4 Ix(A) 9.931 10.03: 10.14 10.251 10.34: 10.431 10.521 10.61 BACKVIEW SIDEVIEW Equivalent Bifacial Output Bifacial Gain 5% I 357 362.25 367.5 372.75 I 378 383.25: 388.5 1393.75 374 379.5 385: 390.5 396 401.5 407 412.5 C 15% ' ' 391 396.75: 402.5 408.25 414 419.75€ 425.5 431.25 Temperature Coefficients (TC)permissible operating conditions SHORT FNAME LONG FRAME .Tc of Open Circuit Voltage(P) -0.27%/°C Tc of Short Circuit Current(a) 0.050%/°C Typical IN Curves4 t Tc of Power(y) :-0.351/o/°C Maximum System Voltage 1500V NO Cal - 45°C t 2°C r i Tempelure Range :-40°C to+85°C I Mech�as ical Data Length z Width x Height 1:1766 x 1050 x 35mm(69.53 x 41.34 x 1.38 inches) Weigflt„ •20.3 Kg(44.75 lbs) nV-1wem• V Junction Box :IP68,Split Junction Box with individual bypass diodes _n Cable&"Connectors" ;200 mm 1+ve terminal)and 300 mm(-ve terminal)Length cables,MC4 41 Average relative efficiency reductienef 5%at 200W/0 according to EN 60904-1. 'Compatible/MC4 Connectors._ ° --. Applicationdiass :ClassA(Safetyclass•ll)-= =__ - Performance Warranty Superstrate :3.2 mm(0:125 inches)high transmission Low iron tempered glass,AR coated 00% Cells :60 Mono4'P.1 RCJ120 half-cells) 90% Back Sheet -._„High Transmittance Composite film with Clear Tedlar@ from Dupont@ so% Frame :Anodized aluminiuri frame with twin wall profile ,py Encapsulant :Polyolefin(POE) 60% 1 YEAR 27YEans Mechanical Load Test :5400 Pa(Snow Load),2400 Pa(Wind Load) Maximum Series Fuse Rating:20 A Packaging Information Warranty and Certifications Quantity/Pallet 1 31 Product Warranty" : 12 years Pallets/Container(40'HC) ( 26 Performance : Linear Power Warranty for 27 years with 2%for 1 st year degradation and 0.55% Quantity/Container(40'HC) 806 Warranty :from year 2 to year 27 "All l"I certifirations under progress. Approvals and : IEC 61215:2016,IEC 61730:2016,IEC 61701,IEC 62716,IEC 60068-2-68^,IEC •-4Refer toVRramS..-warranty document for terms and conddions. Certificates ) 62804, CEC(California),UL 61215,UL61730,CAN-CSA,CE 400mm 115.75 inches),1 000m 139.37 inches),1200mm(47.24 inches] cabte lengths are also available. CAUTION:READ SAFETY AND INSTALLATION MANUAL BEFORE USING THE PRODUCT. Specifications included in this datasheet are subject to change Without notice.Electrical data Without guarantee.Please confirm your exact requirement With the company representative while I,tacing your order. *Vikram Solar&Prexos and the accompanying Logos are trademarks of Vikram Solar Limited registered in India. sales@vikramsolar.com * www.vikramsolar.com VSL/ENG/SC/261 Preens 6-120ce0s-1500v-2022-E-R00-G7 solar=@@ Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US/SE1140OH-US solar-..: ti•�iflwove solar-..: x'•12 25 <,,. i 0 r,.x � s•. o ' J 4 • • M e sl': im ra Optimized installation with HD-Wave technology AV Specifically designed to work with power optimizers I - Record-breaking efficiency I - Fixed voltage inverter for longer strings - Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 I - UL1741 SA certified,for CPUC Rule 21 grid compliance I - Extremely small — High reliability without any electrolytic capacitors 111 111 — Built-in module-level monitoring 11111 I�� — Outdoor and indoor installation wave — Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) I www.solaredge.us $Q l a r ' • • c. Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US/SE1140OH-US SE3000H-US SE380OH-US SE5000H-US I SE6000H-US ISE7600H US SE10000H US SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 330 .(P 208V. ............... 5000 P,208y .............. ................ ................ ........... Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA ............................................ ................ . ... . ............... ................ ................ ........... AC Output Voltage Min.-Nom.-Max. ✓ ✓ Vac 183„208,-229)......................... .............. ............................... ................ ............... . AC Output Voltage Min.-Nom.-Max. 211 240 264 '� V `� '� I/ Vac ✓ ✓ AC Frequency(Nominal 59.3-60-60.51'1 Hz .putt Current ... ............... ................. ................ ............... ................ .. . .... Maximum Continuous Output Current 16 24 A 208V ..................................... ............... ................ ............... ................ ............... ................ ..........,..... ........... Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A ..°Q240V................................... ............... ................ ............... ................ ............... ................ ................ ........... GFDI Threshold A ................................ ........................................................ ....................................................... ........... Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT ..Maximum.DC. .P....ower @240V 4650 5900 7750 9300 11800 15500 17650 W .......... . . .. Maximum DC Power @208V 5100 7750 .. ....... ............... ................ .I............. ................ ................ ........... Transformer-less,UngroundedYes ................................................ .................................................. ........... Maximum Input Voltage................. 480 Vdc.... Nominal DC Input Voltage 380 400 Vdc ............. ... ............. . . . . . . . Maximum Input Current 208V 9 13.5 ............. ............... ............................... ................ .... . Maximum Input Current @240V 85 10:5 135 16:5 20 27 30 5 Adc ...... . . ........... Max:Input Short Circuit CurrentAdc ............................ . 45....................................................... .... Reverse-Polarity Protection .............. ........................................................Yes....................................................... ........... .............. Ground-Fault Isolation Detection 60RIcnSensitivity MaximumInverter Ef..n..Y............. ......9.9......1................................................99:?. .........I................ ....�°..... .................... CEC Weighted Efficiency 99 % ............. ........................................... .................................................. ........... Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485:Ethernet.Zi�Bee(optional),Cellular(optional) ................... ...................................F ...... Revenue Grade,Data,ANSI C12 20,,,, Optionallz> p p ...... ............................................ ...... Rapid Shutdown NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety .................................. UL1741t UL1741 SA:UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 ............... ........... Grid Connection Standards IEEE1547 Rule 21 Rule 14 lHI� ............................................ . ........ .. ...... ......... ........................ ........... Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Ranpe 3/4.'minimum/14-6 AWG 3/4"minimum/14-4 AWG ............... ......................... .... ............................ ........... DC Input Conduit Size/#o f Strings/ 3/4"minimum/1-3 strings/ 3/4"minimum/1-2 strings/14-6 AWG AWG Rang?.............................. ......I...14.-6 AWG ................................................................................ . .... ...... .. ........... 6x7.3/540x3703x14. Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21. X.185.............. in/mm Weight with Safety Switch............... ............22/.1R............�..25.1/114.. .........26.2/11.9....I...... ...........38.8/.17.6.......... Ib k5... Noise <25 <50 dBA ............................................ ................................................................. . . . . ........... Cool. Natural Convection Natural convection . ............................... ................... ................... . Operating Temperature Range 13 to+140/.25 to+601'1(40 F/40�C option)14I %F/'C Protection Rating NEMA 3R(Inverter with Safety Switch 113 For other regional settings please contact SolarEdge support IA Revenue grade inverter P/N:SEm H-USOOONNCZ 133 For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf 163-40 version P/N:SE>o=H-USOOONNU4 I Q SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE • J L J C a - J I System designed with All parts fit in a box for easy maximum versatility for any logistics arrays including staggered Drop-in features make the install process intuitive and fast __—__---_ Simple design allows system to be installed by single installer U Listed to UL Standard 2703 for on the roof L Grounding/Bonding and Fire Classification SnapNrack RL Universal is designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and the highest spans of any current rail less system. Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of J North-South adjustability for all Mounts Mounts • Single mount used at all locations on array Tit • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation ; • Features a rock-in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments ' Links • Simple design provides mounting platform between two to four modules • Clamps onto top of modules securing them in place while providing rl► row-to-row bonding �� • Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules4 • Skirt length is compatible with both portrait and landscape module orientations �= Quality. Innovative . Superior, SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources • improve overall installationquality and • O 2019 by SnapNrack • •unting Solutions.Ali rightsreserved Snap�� �]i"� rack i '�n� °�11f�iI 4 �E �1o11i11 y Solar Mounting Solutions i Series 100 Residential Roof Mount System The SnapNrack Series 100 Roof Mount System is engineered to optimize material use, labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The Series 100 Roof Mount System boasts unique, pre-assembled, stainless steel "Snap- Inf9 hardware and watertight flash attachments. This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire management, solutions for all roof types, one-size-fits-all features, and can withstand extreme environmental conditions. Series 100 is listed to UL Standard 2703 for Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. Appealing design with built-in aesthetics No grounding lugs required for modules All bonding hardware is fully integrated Rail splices bond rails together, no rail jumpers required No drilling of rail or reaching for other tools required Class A Fire Rating for Type 1 and 2 modules c System Features Include Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling 11 J,g ' Integrated Wire Preassembled Integrated bonding UL 2703 Certified Management hardware Resources snapnrack.com/resources 0 Design snapnrack.com/configurator r Where to Buy snapnrack.com/where-to-buy .'i Snapr,l rack- Solar Mounting Solutions i Stainless Bolt with Stainless Steel Bonding Splice standard Rail wEnd plit-Lock Washer Bolt withsplInsert 015-09816Lock Washer nCla Adjustable Bandin Clamp Top Mid Clamp Basee Bonding Bonding Adjustable Channel Nut End Clamp Bottom / Bonding Stainless Channel Nut Stainless Hardware with Bolt with Split-Lock Washers Split Lock Bonding Adjustable Bonding Mld Clamp Bonding Standard Washer End Clamp 242-02053 Rall Splice Ground Lug 242-02067 242-?401S 242-02101 12-6 AWG Copper Wire Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) Universal End Clamp(UEC) Wave UEC Pull Strap j 4 UEC Wedge Stainless Steel Bolt �. with Flat Washer IF Universal End Clamp IF IF z42-02215 Standoff Clamp Assembly Rubber Serrated Stainless Channel Channel Nut Rain Collar Steel Flange Nut Nut Stainless Serrated Stainless Flange Nut Mill Finish Steel Flange Bolt 92 Degree Stainless L Foot Flange Standoff Bolt 0 All Purpose L Foot Mill Finish Standoff Base(1-Hole L Foot Metal Roof Base Shown) o MITI Finish Flashing Base Assembly L Foot Base Metal Roof Base Standoff L Foot Base with Flashing with L Foot 242-92057 242.92050 242-02037 SERIES • • TECHNICAL DATA • 6000 Series aluminum Materials • Stainless steel • Galvanized steel and aluminum flashing • Silver and black anodized aluminum • Mill finish on select products Material Finish • Silver or black coated hardware Note:Appearance of mill finish products may vary and change over time. Wind Loads 110 -190 mph (ASCE 7-10) Snow Loads 0-120 psf Array Pitch O-60 degrees 877-732-2860 P, www.snapnrack.com p contact@snapnrack.com ©2016 by SnapNrack Solar Mounting Solutions.All rights reserved srlanlradcsa+e_100_ &we_21 DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins REVISION: PART NUMBER(S): A 595 MARKET STREET,28711 FLOOR-SAN FRANCISCO,CA 84105 USA PHONE(415)580-6900-FAX(415)580-5802 242-02155 THE DOUR T, IN THIS ORAYANO S C EFLEOF IS PROHIBITED AND PROPRIETARY.ANY REPROOUCi1ON,OISOLOSU O OR USE THEREOF IS UTH WITHOUTTHE NRRTEN CONSENT OF SUNRUN SOUTH U.C.LL 10 5 0 0 4 3 9 7 ® 8 1 2 o 6 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK, RL UNIVERSAL, LEVELER, MILL 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL 4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK 5 1 SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 1 SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS 8 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1IN, SS 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1 BOLT, FLANGE, SERRATED, 3/8IN-16 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 623 UP, 674 DOWN, 505 SIDE ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.73 DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins .5flapN raQlk- REVISION: PART NUMBER(S): A695 MARKET STREET,29TH FLOOR.SAN FRANCISCO,CA 94105 USA PHONE(415)5BM900-FAX(415)580-6902 242-02155 THE WFORMATION IN THIS DRAWING IS CONFIDENTULLANO PROPRIETARY.ANY REPRODUCTION,DISCLOSURE,OR USE THEREOF IS PROHIBITED WITHOUTTHE WRITTEN CONSENT OF SUNRUN SOUTH LLG 1.50 3.41 1.50 Fs� 2.35 1.50 1.55 .66 2.00 1.24 1.00 SLOT sy 2.63 �-1.50— � ALL DIMENSIONS IN INCHES a COMPATIBLE ROOF ATTACHMENTS FOR FD(ED TILT BIN: REVISION: THE FIXED TILT IS A SIMPLE * *1 O *1 i i 5/7/2019 NEW DETAIL MIA SOLUTTIONION FOR INSTALLATIONS / REQUIRING MODULE TILT BEYOND THE 2 6/22/2021 +OMNIBASE ffA C 8/2/2021 D0000595 rvA EXISTING ROOF SLOPE.IT IS DESIGNED o � e D 10125/2021 DCoo0222 WA FOR TILT ANGLES FROM 0°-30°ABOVE e THE HORIZONTAL UTILIZING FIXED — STANDOFF HEIGHTS METAL ROOF BASE: 1-HOLE BASE: 4-HOLE BASE: OMNIBASE BIN 10 BIN 10 BIN 11 BIN 10 THE SNAPNRACK FIXED TILT IS DETAIL:SNR-DC-00352 DETAIL:SNR-DC-00348 DETAIL:SNR-DC-00350 DETAIL:SNR-DC-01249 COMPATIBLE WITH THE VARIOUS DETAIL:SNR-DC-00353 DETAIL:SNR-DC-00349 DETAIL:SNR-DC-00357 DETAIL:SNR-DC-01250 SNAPNRACK ROOF ATTACHMENTS DETAIL:SNR-DC-00358 DETAIL:SNR-DC-01251 PV MODULE,TYP. SHOWN.REFER TO SPECIFIC DETAIL:SNR-DC-00359 DETAIL:SNR-DC-01252 "ATTACHMENT DETAIL" DETAIL:SNR-DC-01253 DETAIL:SNR-DC-01254 REFER TO SNAPNRACK ENGINEERING SNAPNRACK CHARTS FOR APPLICABLE RAIL SPANS. ULTRA RAIL "BIN"NUMBER ON CHART SHOULD MATCH PV MODULE,TYP. SNAPNRACK "BIN"NUMBER ON THIS DRAWING MODULE CLAMPS SNAPNRACK FIXED TILT ANGLE,RELATIVE REFER TO THE SNAPNRACK INSTALLATION TILT,REAR LEG TO HORIZONTAL MANUAL FOR%6"0 HARDWARE TORQUE (LENGTH VARIES) (30°MAX) SPECIFICATIONS SNAPNRACK FIXED TILT ABOVE TILT,FRONT LEG ROOF SURFACE B FOR ADDITIONAL SYSTEM (LENGTH VARIES) (5°-30°) REQUIREMENTS,INCLUDING MODULE — OVERHANG,SEE"SNR-DC-00329 ULTRA ROOF DECKING, RAIL,SYSTEM OVERVIEW,TYPICAL" (ROOFING MATERIAL SNAPNRACK FIXED NOT SHOWN) A TILT,REAR LEG FOR LEVELING REQUIREMENTSSEE (LENGTH VARIES) "SNR-DC-00334 ULTRA RAIL,COMPONENT STRUCTURAL MEMBER, SNAPNRACK FIXED DETAIL,LEVELING SPACER ON STANDOFF" — WOOD RAFTER SHOWN TILT,FRONT LEG SNAPNRACK OMNIBASE CAN MOUNT IN ALLOWABLE ANGLES ROOF PITCH,VARIES (LENGTH VARIES) ANY ORIENTATION ON THE ROOF / — FIXED TILT, INSTALLED RAILS CAN MOUNT ON ANY SIDE OF THE 5/6"-18 BOLT WITH t STANDOFF POST SERRATED FLANGE NUT,S.S. FOR"ROOF PITCH"GREATER THAN 7°, / SNAPNRACK STANDARD "TILT ANGLE"MUST BE IN SAME SNAPNRACK i� STANDOFF,LENGTH VARIES: DIRECTION AS"ROOF PITCH" STANDOFF CLAMP SNAPNRACK AP 90 L FOOT 10",14"OR 23" WITH UR MOUNT HARDWARESNAPNRACK STANDARDSTANDOFF,LENGTH VARIES: 5-1/z"OR 10" RACK ROOF ATTACHMENT-COMPATIBLE21/4" ATTACHMENTS SHOWN ABOVE.REFER TO16 DETAIL A SPECIFIC SNAPNRACK"ATTACHMENT DETAIL" _— UR-40 RAIL UR-60 RAIL FIXED TILT, FRONT LEG DETAIL B FOR USE WITH SNAPNRACK ULTRA SERIES RAILS (RAIL HIDDEN) FIXED TILT, REAR LEG ����n n���n 595 s unrunn South LLC DESIGNER: G.MCHPEETERS SCALE: DNS DRAWING NUMBER: DESCRIPTION: REV: IIJI�\UI I IlTUll1" c a.a w,°s usA "'��°'°°°'"�"°'�°°°� DRAFTER: M.AFFENTRANGER SNR-DC-00335 ULTRA RAIL,SYSTEM DETAIL,FIXED TILT D �.� DATE: 10/25/2021 Solar Mounting Solutions �0�10µp°�°�°X H!"�6^61�P1'F HCd11HImX�B11mK11H°Irt"E APPROVED BY: W.ARBUCKLE