Loading...
HomeMy WebLinkAbout48372-Z �OS11Ffat�cp Town of Southold 5/5/2023 ... G a yam , P.O.Box 1179 W 53095 Main Rd 1y�j01 �ao� � Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44068 Date: 5/5/2023 THIS CERTIFIES that the building GENERATOR Location of Property: 90 Dawn Dr, Greenport SCTM#: 473889 Sec/Block/Lot: 35.-5-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/2/2022 pursuant to which Building Permit No. 48372 dated 10/5/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"accessory generator as applied for The certificate is issued to Ryan Jr,John of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48372 10-31-2022 PLUMBERS CERTIFICATION DATED 0 (700 Signature TOWN OF SOUTHOLD aSUFFot,ra BUILDING DEPARTMENT J TOWN CLERK'S OFFICE r, SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 48372 Date: 10/5/2022 Permission is hereby granted to: Ryan Jr, John PO BOX 2120 Greenport, NY 11944 To: legalize "as built" generator as applied for. At premises located at: 90 Dawn Dr, Greenport SCTM #473889 Sec/Block/Lot# 35.-5-11 Pursuant to application dated 9/2/2022 and approved by the Building Inspector. To expire on 4/5/2024. Fees: CERTIFICATE OF OCCUPANCY $50.00 ACCESSORY $200.00 ELECTRIC $170.00 Total: $420.00 Building Inspector pF SO!/T�QI 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(a-town.southold.ny.us Southold,NY 11971-0959 �Q �yC4UNTV,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: John Ryan Jr Address: 90 Dawn Dr city:Greenport st: NY zip: 11944 Building Permit#: 48372 Section: 35 Block: 5 Lot: 11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: GJS Electric License No: 4839ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 20kW Kohler Generator w/200A Whole House Transfer Switch Notes: Generator Inspector Signature: Date. October 31, 2022 S. Devlin-Cert Electrical Compliance Form hO��OF SOUlyolo - - f # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ]" ULATION/CAULKING [ ] FRAMING/STRAPPING ` ' [ FINAL 6 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: P/ � V�� Y ��Mc h�h�41✓� - , DATE 10 INSPECTOR OFSOGTy�62 * # TOWN O SOUTHOLD BUILDING DEPT. f% 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: [.,l g&g e r 715-; A/ DATE 10 INSPECTOR https://mail.google.com/mail/u/0/ pill.'-- ''7°r✓^c"i' 61, P[(DKK YROP41i6 ^'� ll � n ,. ,'ry �v yj }'�r '}Y"'•� (!(U,6 ` i su[.Fwlo.(m,lillN 1 C�� �r. •'�}`} a UN 1015 6;,'39 4z99 k, ,Y Y tit. ��; f•-�� {,t r 1 �.._ --- w._-_- .Y1. i��r ��' ,,.:�:��,. ` 4 • � � 00 �WAR � y �+ PP W1 E roe ^T T JAY. �1�, Kike �iaY -j^ �ha'�r 1.t Y`�•f `+� ��t,,� \ ^r '�• r r.� �Y � ,S P+:�4 ` jC.tr'. '1J��`l ; ����w� '1�• ,!T �° Ii�,P``f �1 ��y , �� .®.���,�,,;��,-.� '�'i.;+^� ►� lr `fin^� r1 .''� -� �.v� d�o,�� 1►•^'!{ie,� �r �' •.tr.:�, '^�,��W'�}Y j.^.�+�' ., d r<VI �■ Tr�su+ _'Ai Iofl �`�� 05/02/2023, 1:04 PM FIELD INSPECTION REPORT I DATE COMMENTS b FOUNDATION (1ST) � a ------------------------------------ C FOUNDATION (2ND) z 0 ROUGH FRAMING& r n PLUMBING ,g kA INSULATION 1 Vd �p r INSULATION PER N.Y. STATE ENERGY CODE V.01A t,✓w%1 it PUk . liv lc-s FINAL ADDITIONAL COMMENTS 13 P-4 H 6 2.� I 0 - io I`0-3�� z �X G b N � 0 z H d CEJ 'b H oS.yFFar.KcoG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 � ,• a� Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtowmy.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: , SEP Applicat'ions'and forms,,must:be fillgd o.ut.-in their entirety.,(n`c'omplete .. x' D ,,�. BUILDINGE applications will not:be.accepted::Where the'Applicant is;not;th;e.owner,an, TOWN OF 80 OLD 0wn'er's'Authorization;form;(Page:2)shall be conil `d 'i ;,, Date:July 13, 2022 R(S):OF'PR'OPERTY: :., OWN ER(S): Name:John Ryan SCTM#1000-35-5-11 Project Address:M Dawn Drive, Southold NY 11944 917-921-0000 : JRYANSPC GMNI .COM vP µone#: ,. Email: _._... ..u..._.._....��s_.,.._. __.. _,�_..,m�.._.._-.....__.._E.�.,._...._. ..._ .._...,� MailingAddress:P.O. BOX 2120,, Oreemort NY 11944-0972 CONTACT PERSON:: „ Name: Todd O'Connell Address: Hy,„ste 120, Hauppauge NY 11788 Mailing.: :.,..._. 1200 Vetsw __- ...._._.-.. ._-a -._ �.. .., y .......-..._..,, w.�. _-.. .,_ _ _-. ..........w.. . .�._.,.:w_..._, .. Phone#:631-650-6666 Email:Permits@TOCArchitects.com DESIGN PROFESSIONALINFORMATION: Name:Todd O'Connell Mailing Address_1200 Vets Hwy, ste 120, Hauppauge NY 11788 Phone#: 31-650-6666 l:Permits TOCArchitects.com _.. .. . 6 _ ._ _._...._....._............__....... .. - _ .. ._._...__..._....._,._..._..__._.. Emal... ...............�_._�. - -._....__.. ....._�_ . 'CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: ,'DESCRIPT.ION.DF-PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: VOthe rC.,2(1e rgA b'r M a I 4al t� $_.. Will the lot be re-graded? ❑Yes SKNo Will excess fill be removed from premises? ❑Yes 0 N 1 PROPERTY] , Existing use of property:sln le famil residential Intended use of property:single family residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_4 Q this property? ❑Yes ONo IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/de sign"profossional is responsible for all drainage and storm water issues as provided.by. Chapter 236 of the Town Code. APPLICATION IS HER EBY.MADE to the Building Department for the issuance,of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alteration's or for'removal or demolition as herein described.,The applicant agrees to comply with all applicable laws,ordinances;building code, housing code and regulation's and to admit authorized.inspectors<ompremises and in building(s)for necessary inspections.False statements'made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. t Application Submitted t'"By(prl t n ):J n yan ❑Authorized Agent BOWner Signature of Applican ' Date: 07/13/2022 STATE OF NEW YORK) , SS: COUNTY OF Suffolk John Ryan being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Owner (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 13 day of July 12022 P"otary Public PROPERTY OWNER AUTHORIZATIONCNotary MICHEc-StatofSIMMONS Public-State of New York N0.01S16097359 (Where the applicant is not the owner) ualified in Suffolk County mmission Expires Sep 15,2023 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 ��g11FF0(,�co � BUILDING DEPARTMENT-Electrical Inspector hyo G��kt TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road - PO Box 1179 C4 z �# Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(c-southoldtownny.gov seand(a southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali Information Required) Date: Company Name: GJS Electric, LLC Electrician's Name: Gary Salice License No.: 4839ME Elec. email:gary@nfay.com Elec. Phone No: 631-298-4545 211 request an email copy of Certificate of Compliance Elec. Address.: 6615 Main Rd., Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: -To yA Address: ,r, 6,reen P,:,r49 Cross Street: " Phone No.: Al li'-p,a I - p 00 Bldg.Permit#: email: Tax Map District: 11 O 0 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES❑NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 0 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION l` Electrical Inspector OFFpIq� `:_;.? BUILDING DEPARTMENT- j�y0�� TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road - PO Box 1179 E ` Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a�southoldtownny.cov - seand(cbsoutholdtownny. ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: GJS Electric, LLC Electrician's Name: Gary Salice License No.: 4839ME Elec. email:gary@nfay.com Elec. Phone No: 631-298-4545 01 request an email copy of Certificate of Compliance Elec. Address.: 6615 Main Rd., Mattituck, NY 11952 JOS SITE INFORMATION (All Information Required) Name: � (c A, Address: 00 b \x1 Cross Street: Phone No.: _q , I - c)UU Bldg.Permit#: 9- email: Tax Map District: 10 0 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: . Circle All That Apply: Is job ready for inspection?: YES❑ NO 0 Rough In Final Do you need a Temp Certificate?: ❑ YES ❑NO Issued On Temp Information: (All information required) Service SizeF-11 PhF—]3 Ph Size: A #Meters Old Meter# ❑New Service0 Fire ReconnectOFlood Reconnect❑Service Reconnect❑Underground ElOverhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y ON Additional Information: PAYMENT DUE WITH APPLICATION PERMIT # Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven W/D V' Smokes DW Mini Carbon Micro Generator Combo Cooktop Transfer AC AH Hood Service Amps Have Used Special: Comment P i SYMBOL LEGEND 0 MONUMENT FND FIRE HYDRANT (M GAS METER FE. FENCE 0 I.P. /I.B. FND ® MANHOLE ® WATER METER MAS. MASONRY (D I.P. /I.B. SET ® •A"-INLET pd GAS VALVE PLAT. PLATFORM *Tp3pa SPOT ELEVATIONS ® "B"-INLET WATER VALVE W.W. WINDOW WELL �—� TRAFFIC SIGNAL POLE ® •E"-INLET 101' TEST HOLE B/W BAY WINDOW �QD UTILITY POLE ® YARD INLET TREE C/E CELLAR ENTRANCE GUY WIRE ® YARD INLET SHRUB 0/H OVERHANG o� UTILITY POLE W/LIGHT ® CABLE TV BOX 0 BOLLARD R/0 ROOF OVER )Y( LIGHT POLE Z A/C UNIT ® WETLAND FLAG L.S.A. LANDSCAPED AREA �- SIGN (M ELECTRIC METER CANT. CANTILEVER D.C. DEPRESSED CURB T i •°I yI ;� ;a tp'f 7� WIGGINS LANE' I I (50' WIDE) L_EDGE OF PAVEMENT_ __ —___ EDGE OF PAVEMENT_______ •�� SLATE RET. � I :j N66039'50"E 197.35, WALL(12•) �\ a - - — — - - -. WALLIFONAll FEN m 3.7' V 1.4' m WALL ° 0.5• r; O 0m a i I ;? I FM LOT 76 ASPHALT SLATE WALK 1 TAX LOT 11 DRIVEWAY F/S 6.3' 2. p TAX LOT 28.2 I F ®��o �a.o N RTD tit xl �• �Cio' a __--20.3' �_ - _-' 24.1 38.1 1R GARAGE _- ,--_ --_ a CHAIN f �- ]' v sl i� •�! ;��w UN FEN. _ -" ST-ORY _" 1 a �i .� B - -- -,FRAME,R0E0SIDENCE ~ "'s -► - GA I4 FEN - _ ^' `° J, -20.2 "" N \Liu. r . 2.3'I /S 12.0 42.8' Izo I 5.0' I �I I O ® PAno TE 60K 41,4' J O ) A Q I I O FENO I 2.8TE► -:( FIND.• 0.44 I ,1 MON. SLATE WALL(12") Q + • 0.7 - FEN S/ry0022'20»LT ® '�� — �, CHAIN LINK FEN. 40 O i0.3, �� II 154-72' ZN J GATE 33.7' I z 00 FM LOT 75 > 11 TAX LOT >2 z Z J z # 1, A � .I rri `� p^ •J u y 6 00 UJB C.>C) i SM v > c v a CFIAIN LINK z .. FEN, f•j � 33.9' I � I k,l t,. FM LOT 74 L` TAX LOT >9 I? %3 ,I I tT LOT AREA 29,315.94 S.F. GRAPHIC SCALE 0.67 Ac. 30 0 15 30 GUARANTEED T0; '. JOHN R. RYAN JR. STEWART TITLE INSURANCE COMPANY ( IN FEET ) LOANDEPOT.COM LLC. 1 inch = 30 ft. ISAOA/ATIMA j OF NEW LAND SURVEY OF PROPERTY Yp SCALICE LOT 75 AND 76 �P 6� J ScSURVEYING P.C. MAP OFCEJ � CLEAVES POINT a Always On Point SECTION NO. 3 I 99-io5 West Hoffman.Avenue, Lindenhurst, New York 11757 FILE DATE: 06/14/1966 MAP NO. 4650- Email:MJScalice@mjslandsurvey.com Phone:63-1-957-240o Fax:631-226-2400 II N O� SITUATE CFiy °•05055 ki DR.:MC CREW.:AL SCALE: 1" = 30' SUFFOLK TAX MAP NO. GREEN PORT, TOWN OF SOUTHOLD ;' SFS LAND S 0100-035.00-05.00-011.000 SUFFOLK COUNTY, NEW YORK DATE SURVEYED:04/30/2019 JOB No.S19-0798 993(1))r,,=ORIZED ALTERATION OR ADDITION TO THIS SURVEY AIIP BEARING A UCENSED IAN.SURVEYOR'S SEAL IS A VIOLATION OF SECTION 7208,SUB—DMSION 2,OF NEW YORK STATE EDUCATION LAW.(2)ONLY BOUNDARY SURVEY NAPS WffN THE SURVEYORS flABO55ED SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE SURVEYORS ORIGINAL WORK AND OPINION, i ,y(3)CFSTIBTCATIONS ON THIS BOUNDARY SURVEY MAP SIGNIFY THAT THE MM WAS PREPARED IN ACCORDANCE WITH THE CURRENT EXISTING CODE OF PRACTICE FOR LAND SURVEYS ADOPTED BY THE NEW YORK STATE ASSOCIATION OF PROFTSSIONAL HAND SURVEYORS INC.THE CERTIFICATION IS LIMITED TO PERSONS FOR WHO THE BOUNDARY SURVEY YAP 6 PREPARED,TO , J]THE TITLE COMPANY,TO THE GOVERNMENTAL AGENCY,AND 1D THE LENDING INSTTMION LASTED ON THIS BOUNDARY SURVEY MAP.({)THE CERTIFICATIONS HEREIN ME NOT TRANSFERABLE(5)THE LOCATION OF UNDERGROUND IMPROVEMENTS OR ENCROACHMENTS ME NOT ALWAYS KNOWN AND OFTEN MUST BE ESTIMATED.IF ANY UNDERGROUND WPROVEMENTS OR ENCROACHMENTS EXIST OR ARE SHOWN,THE IMPROVEMENTS OR ENCROACHMENTS ARE NOT COVERED BY THIS SURVEY.(8)THE OFFSET(OR DIMENSIONS)SHOWN HEREON FROM THE STRUCTURES 70.INE PROPERTY ONES ME FOR A SPECIFIC PURPOSE AND USE AND THEREFORE ME NOT INTENDS.YO GUIDE TNN ERECTION OF FENCES.RETAINING WALLS,POOLS,PA705 , ,�^PLANTING MEAS,ADDITIONS TO BUILDINGS,AND ANY OTHER TYPE OF CONSTRUCTION:m PROPERTY CORNER MONUMENTS WERE NOT SET AS PMT OF THIS SURVEY.(B)THIS SURVEY WAS PERFORMED WITH A SPECTRA FOCUS 30 ROBOTIC TOTAL STATION. (B)THE EXISTENCE OF RIGHTS OF WAY ANO/OR EASEMENTS OF RECORD IF ANY.NOT SHOWN ME NOT GUARANTEED• ,IA APPROVED AS NOTED DATE: 5 B.P:# 3 FEE: BY: C7L- -4L NOTIFY BUILDING DEPARTMENT AT 765=1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTR'_CT!ON MUST BE COMPLETE F:.P ALL CONSTRUCTiCI\, SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF solo��� S.GUW.., ; id�t VNING BOARD SOU19GLaT$ftN USTEES AI V C npn OCCUPANCY OR USE IS`'UNLAWFUL WITHOUT CERTIFICA OFOCCUPANCY ELECTRICAL INSPECTION REQUIRED t KOHLER. Models: 20RCA(L.) Multi-Fuel LPG/Natural Gas 09001 Standard Features 4 KOHLER. • RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and -"° """" N. transfer switch functions (with optional Model RXT). o Electronic speed control responds quickly to varying demand. r,... ,. • ^' u, o OnCue@ Plus Generator Management System for remote monitoring is included with the generator. 4'? $`' `F "� • Kohler Command PRO�v Engine Features 9. o Kohler Command PROD OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. "� • Designed for Easy Installation o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. o Fuel and electrical connections through the enclosure wall The Kohler® Advantage eliminate the need for stub-ups through the base. o Customer connection terminal block located near the • High Duality Power controller allows easy access for field wiring. Kohler home generators provide advanced voltage and o Designed for outdoor installation only. frequency regulation along with ultra-low levels of • Certifications harmonic distortion for excellent generator power quality to protect your valuable electronics. o Meets emission regulations for U.S. Environmental Protection Agency(EPA)with both natural gas and LPG. • Extraordinary Reliability o UL 2200/cUL listed (60 Hz model). Kohler is known for extraordinary reliability and o CSA certification available(60 Hz model). performance and backs that up with a premium 5-year or o Accepted by the Massachusetts Board of Registration of 2000 hour limited warranty. Plumbers and Gas Fitters. • Powerful Performance o Meets 181 mph wind rating. Exclusive Powe§boost'" technology provides excellent starting power. • Approved for stationary standby applications in locations served by a reliable utility source. • Aluminum Enclosure as o Attractive aluminum enclosure allows installation ass. . 20RCAL models packaged with a Model RXT automatic close as 18 inches from your home or small businetransfer switch are available. See page 4 and the Model RXT ATS specification sheet. o Enclosure panels can be removed without tools to allow easy access for maintenance and service. • Warranty o 5-year/2000 hour limited warranty for on-grid(standby) applications in locations served by a reliable utility source. Generator Ratings Standby Ratings Line Circuit Natural Gas LPG Breaker Alternator Voltage Phase Hz kW/kVA Amps kW/kVA Amps Amps Poles 2F7 120/240 1 60 18/18 75 20/20 83 100 2 120/208 3 60 17/21 58 17/21 58 70 3 2G7 120/240 3 60 17/21 51 17/21 51 60 3 277/480 3 60 17/21 26 17/21 26 30 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS:Standby ratings apply to installations served by a reliable utility source.All single-phase units are rated at 1.0 powerfactor.The standby rating is applicable to variable loads with an average load factor of 80%for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO-3046/1,BS5514,AS2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:ALTITUDE:Derate 4%per 305 m(1000 ft.)elevation above 153 m(500 ft.).TEMPERATURE:Derate 2%per 5.5°C(10°F)temperature increase above 16°C(60°F). Availability is subject to change without notice.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co.generator distributor for availability. § Check the appliance manufacturer's specifications for actual power requirements.Consult a Kohler©Power Systems professional to calculate your exact residential power system requirements. t Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure. G4-272 (20RCA) 5/21d Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator a Compliance with NEMA, IEEE,and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole,Rotating Field a Self-ventilated and dripproof construction. Leads,quantity 2F7 4 a Windings are vacuum-impregnated with epoxy varnish for 2G7 12 dependability and long life. Voltage regulator Digital a Superior voltage waveform and minimum harmonic Insulation: NEMA MG1-1.66 distortion from skewed alternator construction. Material Class H a Digital voltage regulator with t1.0% no-load to full-load Temperature rise 130°C Standby RMS regulation. Bearing:quantity,type 1,Sealed a Rotating-field alternator with static exciter for excellent Coupling Direct load response. Amortisseur windings Full a Total harmonic distortion(THD)from no load to full load with Voltage regulation,no-load to full-load RMS ±1.0% a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240 V,1 ph 2F7(4 lead);. 41 (60 Hz) 240 or 480 V,3 ph 2G7(12 lead) 69(60 Hz) Application Data Engine Exhaust Engine Specifications Exhaust System Manufacturer Kohler Exhaust temperature exiting the Engine:model,type CH 1000 4-Cycle enclosure at rated kW,dry,°C(°F) 260(500) Cylinder arrangement V-2 Lubrication Displacement,cm3(cu.in.) 999(61) Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3.1) Lubricating System Compression ratio 8.8:1 Type Full Pressure Main bearings:quantity,type 2,Heavy-Duty Sleeve Oil capacity(with filter),L(qt.)§ 1.9(2.0) Bearings Oil filter:quantity,type§ 1,Cartridge Rated RPM Oil cooler Integral 60 Hz 3600 § Kohler recommends the use of Kohler Genuine oil and filters. Max.engine power at rated rpm,kW(HP) LPG,60 Hz 23.0(30.9) Fuel Pipe Size Natural gas,60 Hz 20.2(27.1) Cylinder head material Aluminum Minimum Gas Pipe Size Recommendation,in.NPT Valve material Steel/Stellite® Pipe Length, Natural Gas LPG m(ft.) 281,000 Btu/hr. 340,000 Btu/hr. Piston type and material Aluminum Alloy Crankshaft material Heat Treated,Ductile Iron 8 (25) 1 3/4 Governor:type Electronic 15 (50) 1 1 Frequency regulation,no load to full load Isochronous 30 (100) 1 1/4 1 Frequency regulation,steady state t0.5% 46 (150) 1 1/4 1 1/4 Air cleaner type Dry 61 (200) 1 1/4 1 1/4 Engine Electrical Engine Electrical System Ignition system Electronic, Capacitive Discharge Starter motor rated voltage(DC) 12 Battery(purchased separately): Ground Negative Volts(DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA)rating for-18°C(0°F) 500 Group size 51 G4-272 (20RCA) 5/21d Fuel Requirements RDC2 Controller Features, Continued Fuel System • LED indicators for utility power and generator set source Fuel types Natural Gas or LPG availability and ATS position (Model RXT transfer switch Fuel supply inlet 1/2 NPT required) Fuel supply pressure,kPa(in.H2O): • LCD display: Natural gas 0.9-2.7(3.5-11) o Two lines x 16 characters per line LP 1.7-2.7(7-11) o Backlit display with adjustable contrast for excellent Fuel Composition Limits* Nat.Gas LPG visibility in all lighting conditions Methane,%by volume(minimum) 90 min. - • Scrolling system status display: Ethane,%by volume(maximum) 4.0 max. - o Generator set status o Voltage and frequency Propane,%by volume 1.0 max. 85 min. o Engine temperature Propene,%by volume(maximum) 0.1 max. 5.0 max. o Oil pressure C4 and higher,%by volume 0.3 max. 2.5 max. o Battery voltage Sulfur,ppm mass(maximum) 25 max. o Engine runtime hours Lower heating value, MJ/m3(Btu/ft ),(minimum) 33.2(890) 84.2(2260) • Date and time displays * Contact your local distributor for suitability and rating derates based • Smart engine cooldown senses engine temperature on fuel compositions outside these limits. • Digital isochronous governor maintains steady-state speed at all loads Operation Requirements • Digital voltage regulation: *1.0% RMS no-load to full-load Fuel Consumption,m3/hr.(cfh)@ 60Hz • Automatic start with programmed cranking cycle %Load Natural Gas LPG • Programmable exerciser can be set to start automatically on 100 8.0 (281) 3.9 (136) any future day and time,and run every week or every two 75 6.9 (243) 3.1 (109) weeks 50 4.6 (161) 2.3 (82) • Exercise modes: 25 3.6 (127) 1.7 (59) o Unloaded weekly exercise with complete system Exercise 2.0 (71) 1.0 (35) diagnostics Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) o Unloaded full-speed exercise LPG: 93 MJ/m3(2500 Btu/ft.3) o Loaded full-speed exercise(Model RXT ATS required) LPG conversion factors: 8.58 ft.3=1 Ib. • Front-access mini USB connector for SiteTech- or USB 0.535 m3=1 kg Utility connection 36.39 ft.3 =1 gal. • Integral Ethernet connector for Kohler®OnCue@ Plus Generator Set Sound Data • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection Model 20RCA 8 point logarithmic average sound levels are of a Model RDT transfer switch 66 dB(A) during weekly engine exercise and 70 dB(A) during • Diagnostic messages: Displays diagnostic messages for the full-speed generator diagnostics and normal operation.* engine,generator, Model RXT transfer switch, programmable All sound levels are measured at 7 meters with no load. interface module (PIM),and load management device. • Maintenance reminders * Lowest of 8 points measured around the generator. Sound levels at other points around generator may vary depending on installation • System settings: parameters. o System voltage,frequency,and phase o Voltage adjustment RDC2 Controller o Measurement system, English or metric • ATS status(Model RXT ATS required): o Source availability 9e: 2,° o ATS position (normal/utility or emergency/generator) Freq: 60.0 Hz O o Source voltage and frequency O ���, o • ATS control (Model RXT ATS required): rdo o Source voltage and frequency settings o Engine start time delay o Transfer time delays o Voltage calibration The RDC2 controller provides integrated control for the o Fixed pickup and dropout settings generator set, Kohler@ Model RXT transfer switch, • Programmable Interface Module(PIM)status displays: programmable interface module(PIM),and load shed kit. o Input status(active/inactive) o Output status (active/inactive) RDC2 Controller Features • Load control menus: • Membrane keypad: o Load status o OFF,AUTO,and RUN pushbuttons o Test function o Select and arrow buttons for access to system configuration and adjustment menus • LED indicators for OFF,AUTO,and RUN modes G4-272 (20RCA) 5/21d KOHLER® PhoneKOHL9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com ' Generator Set Standard Features Automatic Transfer Switches and Accessories • Battery cables ❑ Model RDT ATS • EPA certified fuel system ❑ Model RXT ATS • Aluminum sound enclosure ❑ Model RXT ATS with combined interface/load management board • Critical silencer ❑ Load shed kit for RXT or RDT • Field connection terminal block ❑ Power relay modules (use up to 4 relay modules for • Fuel solenoid valve and secondary regulator each load management device) • Line circuit breaker ❑ Other Kohler@ ATS • Multi-fuel system,LPG/natural gas,field-convertible 20RCAL Model Packages • Oil drain extension with shutoff valve ❑ 20RCAL with 100 amp RXT with 16-space load center and • OnCue@ Plus Generator Management System NEMA 1 steel enclosure for indoor installation • Premium 5-year limited warranty ❑ 20RCAL with 200 amp service entrance-rated Model RXT • RDC2 generator seVATS controller with combined interface/load management board and • Rodent-resistant construction corrosion-resistant NEMA 3R aluminum enclosure • Sound-deadening,flame-retardant foam per UL 94, Warranty class HF-1 ❑ 5-Year Comprehensive Limited Warranty Available Options ❑ 10-Year Comprehensive Limited Warranty Approvals and Listings ❑ CSA approval Concrete Mounting Pads ❑ Concrete mounting pad,3 in.thick ❑ Concrete mounting pad,4 in.thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120VAC ❑ Battery heater,240VAC ❑ Cold weather package, 120VAC Generator Set Dimensions and Weights ❑ Cold weather package,240VAC L] Emergency stop kit Generator Set Size,L x W x H: 1193 x 6.2 x 2.2 mm ❑ PowerSync®Automatic Paralleling Module(APM) (47 x 26.2 x 32.2 in.) (single phase only;parallel two 20kW residential generator Shipping Weights: sets with the RDC2 controller) 20RCA Generator Set: 252 kg(555 Ib.) 20RCAL with 100 A FIXT ATS w/L277 k611 ❑ Programmable interface module(PIM) 20RCAL with 200 A RXT SE ATS: 272 kg(600 Ib)lbs.) (provides 2 digital inputs and 6 relay outputs) �_ L •� Fuel System Accessories ❑ Flexible fuel line(included on QS models) ❑ Carburetor heater, 120 VAC ❑ Carburetor heater,240 VAC H ®� Carburetor heater is recommended for reliable starting V at temperatures below 0°C(32°F) Literature ❑ General maintenance literature kit ❑ Overhaul literature kit W NOTE:Dimensions are provided for reference only and should not be used for planning ❑ Production literature kit Installation.Contact your local distributor for more detailed information. Maintenance DISTRIBUTED BY: ❑ Maintenance kit(includes air filter,oil,oil filter,and spark plugs) ©2018 Kohler Co.All rights reserved. G4-272 (20RCA) 5/21d GLIMATIG AND OEOORAFHIG DESIGN CRITERIA TAEL.E 8501.20) WIND DESIGN SUBJECT TO DAMAGE FROM GROUND SPEED TOPOG 5PECIAL WIND SEISMIC §ARC Ft i T E C T S TODD O'CONNELL SNOW (MPH) RAPHIG WIND BORN DESIGN WEATHERING FROST LINE TERMITE WINTER ICE FLOOD AIR MEAN A RCH ITECT P.C. LOAD EFFECT5 REGION ' DEBRIS CATEGORY a DEPTH b DESIGN BARRIER H,AZARD5 9 FREEZING ANNUAL __ T'I E , m A k ZONE f TEMP ` REQUIRED n INDEX ) TEMP J 130vu1t NO NO I M G S 30 TODD O'CONNELL, AIA BOF 3 FT MOD TO FEMA ----- --- I\ _ LE B I 1 E ERE I --- 5 V __ BFG HEAVY IS YE5 FLOOD 1500 OR 55.4 1200 Veterans Memorial Hi hwa FROM RE g Y \ COAST MAP LE55 Suite 120 I _ \ I I I PAN7-L# Hauppauge,NY 11788 MANUAL J DESIGN CRITERIAn P(631) 650-6666 1 • � �ELEVATION LATITUDE WINTER SUMMER ALTITUDE CORRECF(631)650-6667 TION INDOOR DESIGN DESIGN TEMPERATURE HIGH TEMPERATURE C 658-0325 HEATING GOOLING FACTOR TEMPERATURE COOLING 516OOLING DIFFERENCE ( ) 47 � ______ ------ ------ -- ��r���,;r,rT,r:r��;t�r, y� r � 3 5 « � I ���!'���I�i��313���•�r��8�3 — GOOLING WIND WIND COINCIDENT DAILY RANGE WINTER HUMIDITY SUMMER HUMIDITY ` 11 _ ...�.•.' ' TEMPERATURE VELOCITY VELOCITY NET BULB 0 39�50 C �,,,. -�� � DIFFERENCE HEATING COOLING N66 - .. . - ' I TO THE BEST OF MY KNOWLEDGE, BELIEF AND ; z PROFESSIONAL JUDGEMENT, THESE PLANS , t AND/OR SPEGIFIGATIONS ARE IN COMPLIANCE FOUNDATION WATERPROOFING � N N WITH THE FOLLOWING. INSTALL TW0 LAYERS OF TOWELED ON —� F15EROLA55 MASTIC. (FED. SPEC. ° 0 2020 RESIDENTIAL CODE OF NEW YORK STATE 5.5.G. 155 TYPE-1) MEMBRANE TO BE Q I PUBLICATION NOVEMBER 20111 CONTINUOUS FROM TOP OF -�- I FOUNDATION AND EXTEND TO LAP 0 I 2020 RESIDENTIAL CODE OF NEW YORK STATE EDGE OF FOOTING. ASPHALT O I CHAPTERS 12-25 FOR MECHANICAL SYSTEMS m ODRIVEWAY SLATE WALK _ C) 2020 RESIDENTIAL GODS OF NEW YORK STATE N C I I CHAPTERS 24 FOR FUEL � GAS SYSTEMS NOTE: C 1 FOUNDATIONS CHAPTER 4 DESIGN SITE WORK 1 2020 RESIDENTIAL CODE OF NEW YORK STATE BASED UPON PRESUMPTIVE LOAD 5TAKEOUT 15 TO BE PERFORMED BY A z - GHAPTERS 25-33 FOR PLUMBING SYSTEMS BEARING VALUES OF SANDY GRAVEL LICENSED SURVEYOR. STAKING AND J AND/OR GRAVEL AT 2000 LBS PER LAYOUT ARE TO ESTABLISH ALL LINES -� I Q 2020 RESIDENTIAL CODE OF NEW YORK STATE SOUARE FOOT. GONTRACTOR TO AND BENCHMARKS. VERIFY ALL GIVEN z GHAPTERS 54-42 FOR ELECTRICAL SYSTEMS CONSULT ENGINEER IF DIFFERENT SOIL DATA ON DRAWINGS. IN CASE OF } MATERIALS ARE FOUND UPON DISCREPANCY, RECEIVE JLZ i I 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE EXCAVATION OR TEST HOLE, FOR CLARIFICATION FROM ARGHITEGT I A5 ADOPTED WITH THE 2018 IEGC ALTERNATIVE FOOTING AND PRIOR TO PROCEEDING. EXCAVATE O 14.0 O I FOUNDATION WALL DE51ON °W z�w ° o IL AND BACK FILL FOR WORK INDICATED m �°�`y L THE PROJECT COMPLIANCE METHOD GHOSEN IS TOTAL ON DRAWINGS. STOCKPILE TOPSOIL w° D-w O F 0 o o O 24.1 I UA-ALTERNATIVE AND A RESGHEGK HAS BEEN SUBMITTED OBTAINED FROM STRIPPING DRIVEWAY NAY �jo o�p"-"d 10.4 WITH THESE DRAWINGS. AND BUILDING SITE. STOCKPILE ALL w w w°a v r�, 1S co EXCAVATED MATERIAL. NEW AND ������4�� 20.3 I EXI5TING BAGK FILL MATERIAL AND z w z° TOPSOIL ARE TO BE FREE OF WEEDS, �' z In i D d - TREE ROOTS, ROCKS AND DEBRIS. v w w` 6°z p o ALL SURPLUS MATERIAL THAT 15 _$ z W N 0 1 3'n O UNSUITABLE FOR BAGK FILL MATERIAL w N F°CL G a'0,6 p Cj 1/ STORY FRAME CV GENERATOR TO SHALL BE REMOVED FROM THE SITE. ou�"wo�z,y�n' v N RESIDENCE C-6 ' I PROTECT ALL TREES WITHIN EIGHT Q�9QNQE o?<o w$z-4wOG MAINTAIN FEET OF THE BUILDING. PROPER Qu w, w <Om wwoz>°� APPROVALS MUST BE OBTAINED z BEFORE GOVERING ANY EXCAVATED I 20.2 /� =Nv��Ei Dov O `T J I` I CONCRETE BLOCK a O> =O`�IL o .�� 48.6 ,-w_wwlY ALL CONCRETE BLOCK 15 TO HAVE a w r- Q m u�i u N J,wW=� w-Ni�F ' "DUR-O-WALL" REINFORCING EVERY u`'�;°° W ° cn N 1-1 Aid ❑ THIRD COURSE. FILL TOP COURSE I SOLID. MORTAR MIX TO BE ONE PART §� za'D SLATE PATIO DECK , PORTLAND GEMENT, ONE PART LIME Q LL a W 7 , ❑ PUTTY, AND SIX PARTS SANDR, OONE Q o o Q PART MASONRY GEMENT AND THREE .�� PARTS SAND. CD CONCRETE O M O 1= /` 0. UND R c:) I NO CONCRETE MASONRY WORK 1c`fi SHALL BE DONEE DURING TEMPERATURES OF 40 DEGREES F. IAND FALLING. NO GONGRETE SHALL BE PLACED ON FROZEN SURFAGES. NO ADDITIVES SHALL BE ALLOWED _ WITHOUT WRITTEN PERMISSION OF THE 7: '- ARGHITEGT ALL CONCRETE 15 TO BE LU LU 154.72 MIN. 3,500 P.5.1. AT 28 DAYS � 4,000 S7002212011W PSI FOR GARAGE SLAB. PROVIDE ALL l SLEEVES AND FOUNDATION VENTS AS D REQUIRED BY NYS GODE. UNLESS z INDICATED, ALL FOUNDATION FOOTINGS ARE TO BE A MIN. 8" DEEP ~ V PROJECTING 6" ON EACH SIDE OF THE �I O� � �I FOUNDATION WALL. PROVIDE TWO #4 L t- I`l DEFORMED BARS CONTINUOUS IN THE W FOOTING. ALL 4" THIGK GONGRETE 0 O SCALE: I" = 10'-O" SLABS TO HAVE &X6 10/10 WELDED 0 z WIRE REINFORCING. ANCHOR BOLTS IN ry CONCRETE SHALL BE HOOKED 5/e," X o 12" AT MAX. 5' O.G. PROVIDE BITUMEN Q EXFAN51ON JOINTS BETWEEN SLAB5 Q AND FOUNDATION WALLS. o w 1X ... L, 1 SEP � � 7(i2ZONINO INFOR�ATION `.SECTION: 055.00 BLOCK: 05.00 LOT(S): 011 .000 } ZONE=: R-40 REQ IRED EX 5T O LOT AREA 40,000 50.FT. 14,525 50.FT. FRONTAOE 150 FT. 14-7.55 FT. / < FRONT YARD 50 FT. 47.-1 FT. OLOL FRONT YARD 50 FT. 58.1 FT. � REAR `rARD 50 FT. 20.4-7 FT. LU SIDE "rARD (MIN) 15 FT. 42.P5& FT. ly Dz BUILDINO HEIGHT 55 FT N/A Q LOT COVERAGE 20 % 15 % Q m o ,z a W � < v