Loading...
HomeMy WebLinkAbout48319-Z fQS�EFOLK�;rtr Town of Southold 5/5/2023 y� P.O.Box 1179 53095 Main Rd oy oar Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44072 Date: 5/5/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2570 Route 25,Laurel SCTM#: 473889 Sec/Block/Lot: 125.-3-3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/5/2022 pursuant to which Building Permit No. 48319 dated 9/21/2022 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing accessory garage as applied for. The certificate is issued to Schott,Stephen of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48319 4/5/2023 PLUMBERS CERTIFICATION DATED Autorize0ignature tl � goFFol TOWN OF SOUTHOLD Gy BUILDING DEPARTMENT c x TOWN CLERK'S OFFICE 0-1 . o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48319 Date: 9/21/2022 Permission is hereby granted to: Schott, Stephen 2570 Main Rd Laurel, NY 11948 To: construct roof-mounted solar panels to existing accessory garage as applied for. At premises located at: 2570 Route 25 SCTM #473889 Sec/Block/Lot# 125.-3-3 Pursuant to application dated 8/5/2022 and approved by the Building Inspector. To expire on 3/22/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector pF SO!/r��l 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlinCa)-town.southold.ny.us Southold,NY 11971-0959 COW N,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Stephen Schott Address: 2570 Route 25 city:Laurel st: NY zip: 11948 Building Permit#: 48318 & 48319 Section: 125 Block: 3 Lot: 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Trinity Solar License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 12.4kW Roof Mounted PV Solar Energy System w/ (31) 40OW Modules, DC Disconnect, Inverter, AC Disconnect Notes: Solar Inspector Signature: c Date: April 5, 2023 S.Devlin-Cert Electrical Compliance Form pF so//lh°� # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL ���L [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: a- DATE INSPECTOR �- o��OF SOGTyo L48 :� I/ 5-70 +� Z TOWN OF SOUTHOLD BUILDING DEPT. `ycaurm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR (4S Town of Hempstead, NY July 3, 2022 1 Washington Street, 2nd Floor Hempstead, NY 11550 RE: FEARON GARY&SEMONE Trinity Solar No. 246 Cedar Street 2022-01-659261 Hempstead, NY 11550 To the Building Official: The following information constitutes a summary of the relevant design criteria and recommendations for the support of a new photovoltaic[PV]system on the existing roof framing components at the above-referenced location. Criteria is as follows: 1. Existing roof framing: Conventional roof framing at Roof R1, R2, & R3 is 2x6 at 16 o.c.; existing rafter span= 9'6"; (horizontal projection) 2. Roof Loading: • 3.Opsf dead load (pounds per square foot- PV panels, mounting rails &hardware) • 5.7psf- existing roof loads (1.7psf-2x6 framing, 1.5psf roof sheathing, 2.5psf shingles) • Ground Snow Load-25psf-per AHJ (Authority Having Jurisdiction) • Wind criteria- Exposure Category B, 130mph wind 3. Existing Roof modification - none required; existing roof framing is acceptable for PV installation. The installation, described above, is in general conformance with the manufacturers'specifications and complies with all applicable laws, codes, and ordinances as specified by applicable codes, including the 2020 Residential Code of New York State. The spacing of the mounting brackets cannot exceed a maximum of 48"o.c. between mounting brackets and will be fastened using 5/16"diameter corrosive-resistant steel lag bolts. In order to evenly distribute the load across the roof rafters, there shall be a minimum of 2 mounting brackets per rafter(4" long lag bolts required)and a minimum 2'/2" penetration (embedment)of all bracket lag bolts beyond the roofing materials; this is adequate to resist all stated live loads above— including wind shear. Per NDS Section 12.1.4, pilot holes not to exceed one-half the diameter of the shank need to be bored into the primary framing members for the full length of the threaded portion of the screw to avoid splitting of the framing member. Stainless steel lag bolts are required. Regards, Thor Bojcun, PE OF NSW Structural Engineer-Trinity Solar �R��`CBpf�B J0 o�z , t' T.A Z 7� rn 7Z i1 �CF£SSIONP� NY License No.095675 Trinity Solar 12180 5th Avenue, Unit 1 1 Ronkonkoma,NY 1(631)319-7233 FIELD INSPECTION REPORT I DATE COMMENTS —Zoo m FOUNDATION (1ST) k y -------------------------------------- FOUNDATION (2ND) z N c 0 y ROUGH FRAMING& 1 PLUMBING r INSULATION PER N.Y. y STATE ENERGY CODE 2 �- o• FINAL ADDITIONAL COMMENTS �2 Go -I-- tOa, s — o z m i 'v N y O z x x d b H �S�FFO(�coGr TOWN OF SOUTHOLD—BUILDING DEPARTMENT ?` Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 ':y • o v' Telephone (631) 765-1802 Fax (631) 765-9502 https://www..southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only (� F W/ 1E PERMIT N0. Building Inspector: i Applications and forms must be filled out in their,entirety.Incomplete' .' :` AU 02022 applications will not be.-accepted.' Where the Applicant is hot.the owner,an "— BUILDING DEP`d'. Owner's Authorization.form(Page,2),shall be completed.' TOVVN OP ou71-1fJ1..n Date:.7/08/2022 OWNERS)OF PROPERTY: Name:Stephen Schott CTM# 1000-125.00-03.00-003.000 Project Address:2570-Main Road, Laurel, NY 11948 Phone#:(6,31 ) 478-9623 1 Email:kristi.saroglou@gmail.com Mailing Address:2570 Main Road, Laurel, NY 11948 CONTACT.:PERSON:. Name: Samuel Magliaro MailingAddress:2180 5th Ave Unit 1 , Ronkonkoma, NY 11779 Phone#:(631) 319-7233 Email:Brittany.Gaumer@trinity-solar.com DESIGN PROFESSIONAL INFORMATION: Name: lhor Bojcun Mailing Address:105 Waypoint Drive, Eatontown,.NJJ 07724 Phone#: 631-319-7233 Email: Ihor.Bojcun@trinity-solar.com CONTRACTOR INFORMATION: Name:Trinity Solar-Samuel Magliaro Mailing Address:2180 5th Ave Unit 1 , Ronkonkoma,. NY 11779 Phone#:(631 ) 319-7233 Email:Brittany.Gaumer@trinity-solar.com ••DESCRIPTION OF PROPOSED CONSTRUCTION', ❑New Structure ❑Addition ®Alteration El Repair ❑Demolition Estimated Cost of Project: F�]Other Installation of Hanwha 400 solar panels, kW $53, 835.02 Will the lot be re-graded? ❑Yes 10No Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY-INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. Ii Check BOX After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by 236 of the Town Code.APPLICATION IS HEREBY MADE to the'Building Department for the issuance of a Building Permit pursuant to'the Building Zone Ordinance of the Town.of Southold,Suffolk,County_,New York and other applicable Laws;Ordinances or Regulation3,for the construction of Buildings;' additions;alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)forpecessary inspections.False statements made herein are punishable as a ClassA misdemeanor pursuant-to Section 216.45'6f the New York State Penal Law. Application Submitted By(pri name):S a m u e l M ag I l a ro MAuthorized Agent ❑Owner Signature of Applicant: � Date: -7 Jg'Zc�L2s STATE OF NEW YORK) SS: COUNTY OF ) Samuel M ag I i a ro being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent . (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is-duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of —7TL'L� ,20 a� N ry Public BRITTANY GAUMER NOTARY PUBLIC,STATE OF NEW YORK PROPERTY OWNER AUTHORIZATION N0, 01GA6428115 QUALIFIED IN SUFFOLK COUNTY (Where the applicant is not the owner) MY COMMISSION EXPIRES JAN 10,2026 ,, Stephen Schott residing at 2570 Main Road, Laurel, NY 11948 do hereby authorize Samuel Magliario to apply on my behalf to t e own of Southold Building Department for approval as described herein. Owe s Signature Date Stephen Schott Print Owner's Name 2 of 01 - Electrical0 5 BUILDING DEPARTMENT 10nvppe r AUG TOWN OF SOUTHOLD 8t Town Hall Annex - 54375 Main Road - PO "G B 6 x"01'� -Z Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a)southoldtownny.gov — seandCcD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPEQTIQ.N, ELECTRICIAN INFORMATION. (All'Information Required) Date: 7/0'8/2022, Company Name: Trinity Solar Name: Richard Guaneri License No.: ME-57843 email: Brittany.Gaumer@trinity-solar.com Address: 2180 5th Ave Unit 1, Ronkonkoma, NY 11779 Phone No.: (631) 319-7233 JOB SITE INFORMATION (All Information Required) Name: Stephen Schott Address: 2570 Main Road, Laurel, NY 11948 Cross Street: Franklinville Road Phone NO.: (631) 478-9623 Bldg.Permit#: q email: kristi.saroglou@gmail.com Tax Map District* -- 1000 Section:1250N Block: 0300 Lot: 003000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of a utility approved, grid inter-tied, flush mount, roof Mounted, 31 Hanwha 400 solar panels, 12.4kW, photo voltaic electricity generating system. Circle All That Apply: Is job ready for inspection?- YES NO Rough In Final Do you need a Temp Certificate?: YES Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead 1# Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION al-I Request for Inspection FormAs PtLa 00 �,� guffot/r BUILDING DEPARTMENT- Electrical Inspector y� TOWN OF SOUTHOLD C= Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 y Q� f Telephone (631) 765-1802 - FAX (631) 765-9502 : z rogerrCa_southoldtownny:gov — seand(ccD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 22 zg- Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: e Address: 7 Cross Street: Phone No.: Bldg.Permit#: ! ,�:,S/q email: Tax Map District: 1000 Section: Block: Lot: BRI!�F DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES [—] NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 F1 H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION DATE(MMIDD/YYYY) Q CERTIFICATE OF LIABILITY INSURANCE 5/13/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Mark GraSela Arthur J. Gallagher Risk Management Services, Inc. PHONE FAX 4000 Midlantic Drive Suite 200 A!c No Ext: 886-482-9900 Arc No):856-482-1888 Mount Laurel NJ 08054 ADDRESS: CherryHill.BSD.CertM@AJG.com INSURER(S)AFFORDING COVERAGE NAIC# I INSURERA:Gotham Insurance Company 25569 INSURED TRINHEA-03 INSURERS:National Union Fire Insurance Company of Pittsburg19445 Trinity Solar Inc. 2180 Fifth Avenue, Unit 1A INSURERC:Liberty International Underwriters Ronkonkoma, NY 11779 INSURERD: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:1248340122 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE iADDDL Syy BD POLICY NUMBER MMIDDIYEYYY MMIDDPOLICIYYYY I LIMITS A X ; COMMERCIAL GENERAL LIABILITY GL202100013378 6/1/2021 f 61112023EACH OCCURRENCE $2,000,000 ^—ice DAMAGE TO RENTED I CLAIMS-MADE X OCCUR rPREMISES(Ea occurrence) $100,000 I MED EXP(Any one person) S5,000 it I PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: I GENERAL AGGREGATE $2,000,000 POLICY X ''�PECOT- `_j LOC .� ! PRODUCTS-COM PLOP AGG j S2,000,000 OTHER: I COMBINED SINGLE LIMIT S 2,000,000 B t AUTOMOBILE LIABILITY CA 2960145 6/1/2022 j 611/2023 j(Ea accident) X ANY AUTO I j BODILY INJURY(Per person) S AOWNE ONLY 1 SCHEDULED ! BODILY INJURY(Per accident) S ! AUTOS HIRED NON-OWNED PROPERTY DAMAGE 5 ^�AUTOS ONLY I t AUTOS ONLY PROPERTY A UMBRELLA LAB X 'OCCUR EX202100001871 611/2021 6/112023 EACH OCCURRENCE 55,000,000 C ELD30006989101 6/1/2022 I 611/2023 C X EXCESSLIA13 1 CLAIMS-MADE i 1000231834-06 6/1/2022 6/1/2023 1 AGGREGATE 55,000,000 DED i RETENTION S i Limit x of 55,000,000 S 19,000,000 B WORKERS COMPENSATION WC 13588108 6/1/2022 6/1/2023 iIX I STATUTE EE ROTH- AND EMPLOYERS'LIABILITY Y/N ANYPROPRIETOR/PARTNER/EXECUTIVE I E L EACH ACCIDENT $1,000,000 OFFICER/M EMBER EXCLUDED? 'NIA! 71I(Mandatory in NH) E L.DISEASE-EA EMPLOYEEI S 11,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 B .Automobile i CA 2960145 6/1/2022 1 6/1/2023 iAll Other Units $250/500 Comp!Collusion Ded. I Truck-Tractors and Semi-Trailers $250/500 � I I I I I I DESCRIPTION OF OPERATIONS/LOCATIONS!VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Route 25 AUTHORIZED REPRESENTATIVE Southold NY 11971 ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Workers'vORorersCERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Bard 1 a.Legal Name&Address of Insured(use street address only) 1 b. Business Telephone Number of Insured Trinity Solar Inc. 631-319-7233 2180 Fifth Avenue, Unit 1A 1c.NYS Unemployment Insurance Employer Registration Number of Ronkonkoma,NY 11779 Insured 49-230977 Work Location of Insured (Only required if coverage is specifically limited to 1 d. Federal Employer Identification Number of Insured or Social Security certain locations in New York State, i.e., a Wrap-Up Policy) Number 22-3292324 2.Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) National Union Fire Insurance Company Town of Southold 3b. Policy Number of Entity Listed in Box 1 a" 54375 Route 25 WC 013588108 Southold,NY 11971 3c.Policy effective period 6/1/2022 to 6/1/2023 3d.The Proprietor,Partners or Executive Officers are ❑ included.(only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box 1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. , This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers' Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,1 certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Michael Price (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 114, 0 611/2022 (Signature) (Date) Title: C.E.O.North America Telephone Number of authorized representative or licensed agent of insurance carrier: Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov bm .• %,� ��^�� •� {1! •:;..,y ,. Vic? r:. .,1 2"�:�.. ......... -J Suffolk County Department Labor, Licensing & Of Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE, NEW YORK 11788 DATE ISSUED: 12/15/2016 4 No. ME-57843 SUFFOLK COUNTY Master Electrician License This is to certify that Richard Guaneri NI P "mil. doingbusiness as Trinity Solar Inc. having given satisfactory evidence of competency, is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws, 9 rules and regulations of the County of 0 ill Suffolk, State of New York. NOT VALIDWITHOUT Additional Businesses DEPARTMEN 'TAL SEAL AND A CU,RR-ENT CON-32.WER AFF ASPS ID CARD 9 ' WA j. R'NU S' ;k<-: Rosalie Drago J sf Commissioner 01 - frri, `\_� r+'?:- :ll r��n.,t..1S,�0.:'.��''~^\t� �:i'ui d..���!�'f •/ Suffolk County Dept.of ;} Labor,Licensing&Consumer Affairs MASTER ELECTRICAL LICENSE f Name RICHARD GUANERI Business Name Th.E,-on!roS that the bearer is duly licensed Trinity Solar Inc. by the County of suffolK License Number:ME-57843 Rosalie Drago Issued: 12/15/2016 Commissioner Expires: 12/01/2022 Suffolk County Dept.of en Labor,Licensing&Consumer Affairs 3f C!!s HOME IMPROVEMENT LICENSE Name WILLIAM F CONDIT Business Name This certifies that the Trinity Solar Inc Dearer is duly licensed )y the County of Suffolk License Number: H-52821 Rosalie Drago Issued: 01/29/2014 Commissioner Expires: 01/01/2024 MAIN ROAD* INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM Eit1/ 13 �'y 2570 MAIN ROAD ? JAI _ z LAUREL, NY 11948 ` 0,o 095675 F� �aFESSlO��'� Issued/Revisions r2/8/2023 A2 AS-BUILT pp' Al A"UHT 12/3/2022 A RI NAME 2/7/2022 Pi ISSUED TO TOWNSHIP FOR PERMIT 6/23/2022 VICINITY MAP SITE N0. DESCRIPTION DATE SCALE: NTS Project Title: STEPHEN SCHOTT TRINITY ACCT#:2022-05-704679 Project Address: 2570 MAIN ROAD LAUREL,NY 11948 40.969282,-72.560029 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX Drawing Title: 1. THE INSTALLATION CONTRACTOR IS 8. THE DCVOLTAGE FROM THE PANELS 15 14. B)CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES RESPONSIBLE FOR INSTALLING ALL EQUIPMENT ALWAYS PRESENT AT THE DC DISCONNECT COMPANY SPECIFICATIONS,STANDARDS, kCMIL THOUSAND CIRCULAR MILS AND FOLLOWING ALL DIRECTIONS AND ENCLOSURE AND THE DC TERMINALS OF THE AND REQUIREMENTS kVA KILO-VOLTAMPERE PV-2 ROOF PLAN W/ MODULE LOCATIONS AS BUILT PV SOLAR SYSTEM INSTRUCTIONS CONTAINED IN THE DRAWING INVERTER DURING DAYLIGHT HOURS.ALL 15 THIS SET OF PLANS HAVE BEEN PREPARED kW KILO-WATT PACKAGE AND INFORMATION RECEIVED FROM PERSONS WORKING ON OR INVOLVED WITH FOR THE PURPOSE OF MUNICIPAL AND kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM TRINITY. THE PHOTOVOLTAIC SYSTEM ARE WARNED AGENCY REVIEW AND APPROVAL ONCE L LINE 2. THE INSTALLATION CONTRACTOR I5 THATTHESOLARMODULESAREENERGIZED APPROVED,THE INSTALLATION MCB MAIN CIRCUIT BREAKER AP APPENDIX Drawing Information RESPONSIBLE FOR INSTALLING ALL EQUIPMENT WHENEVER THEY ARE EXPOSED TO LIGHT. CONTRACTOR IS RESPONSIBLE FOR MDP MAIN DISTRIBUTION PANEL 6/23/2022 AND FOLLOWING ALL DIRECTIONS AND 9. ALL PORTIONS OF THIS SOLAR INSTALLING ALL SYSTEM COMPONENTS AS MLO MAIN LUG ONLY DRAWING DATE: INSTRUCTION CONTAINED IN THE COMPLETE PHOTOVOLTAIC SYSTEM-SHALL BE MARKED DESCRIBED IN THE DRAWING PACKAGE. MTD MOUNTED DRAWN BY: 1C MANUAL. CLEARLY IN ACCORDANCE WITH THE 16 ALL INFORMATION�SHOWN MUST BE MTG MOUNTING REVISED BY: IMS 3. THE INSTALLATION CONTRACTOR 15 NATIONAL ELECTRICAL CODE ARTICLE 690& CERTIFIED PRIOR TO USE FOR N NEUTRAL RESPONSIBLE FOR READING AND 705. CONSTRUCTION ACTIVITIES. NEC NATIONAL ELECTRICAL CODE UNDERSTANDING ALL DRAWINGS,COMPONENT 10. PRIORTO THE INSTALLATION OF THIS NIC NOT IN CONTRACT System Information: AND INVERTER MANUALS PRIOR TO PHOTOVOLTAIC SYSTEM,THE INSTALLATION NO# NUMBER INSTALLATION.THE INSTALLATION CONTRACTOR SHALL ATTEND A NTS NOT TO SCALE DC SYSTEM 512E: 12.4kW CONTRACTOR 15 ALSO REQUIRED TO HAVE ALL PRE-INSTALLTION MEETING FOR THE REVIEW ABBREVIATIONS OCP OVER CURRENT PROTECTION M SYSTEM SIZE: 3ODULE COUNT: 311 p POLE M OkW COMPONENT SWITCHES IN THE OFF POSITION OF THE INSTALLATION PROCEDURES, AND FUSES REMOVED PRIOR TO THE SCHEDULES,SAFETY AND COORDINATION. AMP AMPERE PB PULL BOX INSTALLATION OF ALL FUSE BEARING SYSTEM 11. PRIOR TO THE SYSTEM START UP THE AC ALTERNATING CURRENT PHO PHASE MODULES USED: HANWHA 400 COMPONENTS. INSTALLATION CONTRACTOR SHALL ASSIST IN AL ALUMINUM pVC POLY-VINYL CHLORIDE CONDUIT MODULE SPEC M Q.PEAKDUO BLKML-G10+400 4. ONCE THE PHOTOVOLTAIC MODULES ARE PERFORMING ALL INITIAL HARDWARE AF AMP.FRAME PWR POWER _ UTILITY COMPANY: PSEG-LI MOUNTED,THE INSTALLATION CONTRACTOR CHECKS AND DC WIRING CONDUCTIVITY AFF ABOVE FINISHED FLOOR QTY QUANTITY UTILITY ACCT#: 9691115504 SHOULD HAVE A MINIMUM OF ONE CHECKS. AFG ABOVE FINISHED GRADE RGS RIGID GALVANIZED STEEL ELECTRICIAN WHO HAS ATTENDED ASOLAR 12. FORTHE PROPER MAINTENANCE AND AWG AMERICAN WIRE GAUGE SN SOLID NEUTRAL UTILITY METER#: 96357352 PHOTOVOLTAIC INSTALLATION COURSE ON SITE. ISOLATION OF THE INVERTERS REFER TO THE C CONDUIT(GENERIC TERM OF JSWBD SWITCHBOARD DEALTYPE: SUNNOVA 5. FOR SAFETY,IT 15 RECOMMENDED THAT THE ISOLATION PROCEDURES IN THE OPERATION RACEWAY,PROVIDE AS SPECIFIED) TYP TYPICAL INSTALLATION CREW ALWAYS HAVE A MANUAL. COMBINER BOX U.O.I. UNLESS OTHERWISE INDICATED MINIMUM OF TWO PERSONS WORKING 13. THE LOCATION OF PROPOSED ELECTRIC AND CB CIRCUIT WP WEATHERPROOF TOGETHER AND THAT EACH OF THE TELEPHONE UTILITIES ARE SUBJECT TO FINAL CKT CURRENT TRANSFORMER XFMR TRANSFORMER Rev.No. Sheet INSTALLATION CREW MEMBERS BE TRAINED IN APPROVAL OF THE APPROPRIATE UTILITY CT COPPER +72 MOUNT 72 INCHES TO BOTTOM OF FIRST AID AND CPR. COMPANIES AND OWNERS. CU DIRECT CURRENT ABOVE FINISHED FLOOR OR GRADE 6. THIS SOLAR PHOTOVOLTAIC SYSTEM 15 TO BE 14. ALL MATERIALS,WORKMANSHIP AND DC DISCONNECT SWITCH A2 PV 1 INSTALLED FOLLOWING THE CONVENTIONS OF CONSTRUCTION FOR THE SITE DISC DRAWING THE NATIONAL ELECTRICAL CODE.ANY LOCAL IMPROVEMENTS SHOWN HEREIN SHALL BE DWG ELECTRICAL SYSTEM INSTALLER CODE WHICH MAY SUPERSEDE THE NEC SHALL IN ACCORDANCE WITH: EC ELECTRICAL METALLIC TUBING GOVERN. A)CURRENT PREVAILING MUNICIPAL EMT FUSIBLE SWITCH 7. ALL SYSTEM COMPONENTS TO BE INSTALLED AND/OR COUNTY SPECIFICATIONS, FS FUSE WITH THIS SYSTEM ARE TO BE"UL"LISTED.ALL STANDARDS AND REQUIREMENTS FU GROUND EQUIPMENT WILL BE NEMA 3R OUTDOOR GND GROUND FAULT INTERRUPTER FEB 1 5 2023 ; R - RATED UNLESS INDOORS. GFI FREQUENCY(CYCLES PER SECOND) Hz SUR. ING DEPT � TOWN OFSOu ,� tY GENERAL NOTES SOMIAR IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT. 2211 Allenwood Road 877-786-7283 Wall,New Jersey 07719 www.Trinity-Solar.com NOTES:•REFERTO MODULE SPECS FOR MODULE DIMENSIONS ° 'DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE ECOFASTEN CLAMP , ' NEW PV SOLAR MODULE,TYPICAL (REFER TO SPEC SHEET FOR DETAILS) (REFER TO EQUIPMENT SCHEDULE FOR SPECS AND QUANTITIES) SOLAR MODULE SOLAR MODULE I i NEW MOUNTING FOOT/ATTACHMENT mat,- POINTS,TYPICAL(REFER TO ECOFASTEN°L"FOOT ECOFASTEN RAIL LS 90 ENGINEERING LETTER FOR SPACING AND _ X (REFERTO SPECSHEETFOR DETAILS) (REFER TO SPECSHEET FOR DETAILS) _ DETAILS) 1D < N •� ��.` ��HAF(� 0 NEW ECOFA5TEN RAIL,TYPICAL TO BE MOUNTED PERPINDICULAR TO EXISTING ASPHALT SHINGLES ECOFASTEN FLASHING STRUCTURE(REFER TO ECOFASTEN (REFER TO ENGINEERS LETTER FOR SPECS) (REFER TO SPEC SHEET FOR DETAILS) �I+1 /..� SPECIFICATION/DATA SHEET FOR DETAILS I NEW END CLIP,TYPICAL S.S.LAG BOLT APOC SEALANT �� I I\ n / . - br , LEJ (REFER TO ECOFASTEN SPECIFICATION/ (REFER TO ENGINEERS LETTER FOR SPECS) —♦ —— —• ) SOLAR MODULES SHALL NOT DATA SHEET FOR DETAILS .J• EXISTING RAFTER EXCEED PEAK HEIGHT. NEW MID CLIP,TYPICAL (REFER TO ENGINEERS LETTER FOR SPECS) �OAn 095675 DATA SHEET ECOFASTEN OR DETASPECIFICATION r�F w, ATTACHMENT&CLIP DETAIL PV MLS ODULE ATTACHMENT ON ASPHALT SHINGLE ROOFHEIGHT FROM GROUND LEVEL TO PEAK OF ROOF_ fSSI� SCALE:NOT To SCALE SCALE:NOT TO SCALE II►J SCALE:NOT TO SCALE ARRAYSCHEDULE Issued Revisions A2 AS-BUILT2/8/2023 Al AS-BUILT 12/3/2022 R1 NAME 7/7/2022 Pi ISSUED TO TOWNSHIP FOR PERMIT 6/23/2022 NO. DESCRIPTION DATE Project Title: M E R4 STEPHEN SCHOTT R3 _-_--__=J TRINITY ACCT p:2022-05-704679 Project Address: 2570 MAIN ROAD R6 a ------ -____ _ 1 2 LAUREL,NY 11948 a ===__---_ ___ - -_,- 40.969282,-72.560029 cD _ o a Drawing Title: w R1 DO - _ R5 - ---- - J- -- - --------• ----_.. -- - —=-= --,--_, -- AS BUILT PV SOLAR SYSTEM _ -= __--- --___ Drawing Information R7 ______ _______ ____ __ ______ ______- _ __c= DRAWINGDATE: 6/23/2022 _.-�:C DC DRAWN BY: JC REVISED BY: IMS E7z RZ _ =k =______= System Information: r"==L -= r ___ ____ ______ _______- DC SYSTEM SIZE: 12.4kW _____ ____F=E ___= AC SYSTEM SIZE: 10kW MODULE COUNT: 31 DC D MODULES USED: HANWHA400 AC MODULE SPEC#: Q.PEAK DUO BLK ML-G10+400 UTILITY COMPANY: PSEG-LI ROOF 1 UTILITY ACCT#: 9691115504 MODULES:0 NOTES: UTILITY METER M 98357352 PITCH:40° ORIENTATION:61° 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE (CONDUIT TRENCHED APPROX.60 FEET) DEALTYPE: SUNNOVA ROOF 2 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. MODULES:19 2.) ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. CRIENTATION:241 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Rev.NO. Sheet 4.)AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(5)NEC 690.13(E). ROOF 3 5.)ALLOUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. MODULES:12 PITCH:27 6.)ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. /� �]` / _ ORIENTATION:151 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE H r v ROOF4 MODULES:0 QTY SPEC# PITCH: R H:27*ON:331° R1 INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE SP INDICATES NEW PV ONLY SUBPANEL ARRAY SCHEDULE FOR MORE INFORMATION UD INSTALLED OUTSIDE(UTILITY ACCESSIBLE) TO 8E INSTALLED 31 HANWHA 400(Q.PEAK DUO BLK ML-G10+400) J2 ROOFS MODULES:0 INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SE1000CH-USOOOBEi4 • • PITCH:34° F ORIENTATION:331° M INDICATES EXISTING METER LOCATION INDICATE PANELS THAT USE MICRO INVERTERS.REFERpC INDICATES NEW DC DISCONNECT 41" TO EQUIPMENT SCHEDULE FOR SPECS. RO ODULES:D OTHER OBSTRUCTIONS PITCH:34° EP INDICATES EXISTING BASEMENTELECTRICAL PRNEL LOCATION: INDICATES NOUTS OUTSIDE. METER TO BE INSTALLED ORIENTATION:61° EXISTING SOLAR INDICATES EXISTNG SERVICE DISCONNECT ROOF7 MODULES:0 INDICATES NEW INVERTER TO BE PITCH:34° NDICATES NEW FUSED PV DISCONNECTTO BE D 2211 Allenwood Road 877-786-7283 ORIENTATION:241° EO OUTSIDE(UTILITY ACCESSIBLE) INSTALLED OUTSIDE. TS INDICATES EXISTING TRANSFER SWITCH Wall,New Jersey 07719 www.Trinity-Solar.com AC I REFER TO EQUIPMENT SCHEDULE FOR SPECS E4gineer;,License Holder: ARRAY CIRCUIT WIRING NOTES SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS 1. LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY 31-40OW MODULES W/1 SOLAR EDGE 5440 PER MODULE FOR DETERMINING ONSITE CONDITIONS AND 15 ADC MAX PER STRING EXECUTING INSTALLATION IN ACCORDANCE WITH (TOTAL) f� NEC 2017 1 STRING OF 9 MODULES IN SERIES-400 Vmax 4 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON 1 STRING OF 10 MODULES IN SERIES-400 Vmax 4 ��.HAEL 10 ASHRAE MINIMUM MEAN EXTREME DRY BULB 1 STRING OF 12 MODULES IN SERIES- Vmax G� TUB 9d✓/ TEMPERATURE FOR ASHRAE LOCATION MOSTSIMILAR TO '3 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT , JA (HOUSE) ! Z TEMP=-16°C F D I r 1 STRING OF 9 MODULES IN SERIES-400 Vmax LU 400 Vmax I ?,✓ 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED 1 STRING OF 10 MODULES IN SERIES- I ON ASHRAE HIGHEST MONTH 2%DRY BULB 12 STRING TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 e e e e e m= lt7 TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= (GARAGE) I 6'x6' 1 CnQ 0 U 33°C 1 STRING OF 12 MODULES IN SERIES-400 Vmax C I �J JUNCTION i A X5675 F� '1 STRING TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 r n 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN i BOX i FESS IQNR� TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED STATES(PALM SPRINGS,CA IS 44.1°C). FOR LESS THAN 9 DC DISCONNECT I CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED I Issued/Revisions SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING I THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS I qz AS-BUILT 2/8/2023 (ALL OF UNITED STATES) I AT AS-BUILT 12/3/2022 5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS I RI NAME /7/2022 SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT Pi ISSUED TO TOWNSHIP FOR PERMIT 6/23/2022 CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(A)THROUGH(D) NO. DESCRIPTION DATE I 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED I Project Title: TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4) I STEPHEN SCHOTT I 7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE ) IDENTIFIED WITH THE FOLLOWING OUTER FINISH: I TRINITY ACCT#:2022-05-704 POSITIVE CONDUCTORS=RED NEGATIVE CONDUCTORS=BLACK EXISTING 240V 10 NOTE: NEC 210.5(C)(2) 10 120/240VINTERNAL REVENUE GRADE MONITORING I Project Address: 2 UTILITY METER 200MAIN BREAKER CONTAINED WITHIN SOLAR EDGE INVERTER 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV 200A BUSBAR WIRE TYPE RHW-2 OR EQUIVELANTAND SHALL BE SOLAR EDGE P 2570 MAIN ROAD N.RWND-3D-240-MB I PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT LAUREL,NY 11 4 ) SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24"SHALL - _- - I 40.969282,-72.560029 CONTAIN<20 CURRENT CARYING CONDUCTORS AND $ I WHERE EXPOSED TO DIRECT SUNLIGHT SHALL I CONTAIN<_9 CURRENT CARRYING CONDUCTORS. I Drawing Title: 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS LOCKABLE 60A DISCONNECT INVERTER#1 OTHERWISE NOTED FUSED W/60A FUSES 0 AS BUILT PV SOLAR SYSTEM 10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON 240V 10 a + ROOFTOP AND SHALL BE LIMITED TO 12"IF USED OUTDOORS -- I 11.)OVERCURRENT PROTECTION FOR CONDUCTORS �� a 0 i Drawing Information CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE o ¢0 u' _-J DRAWING DATE: 6/23/2022 LOCATED WITHIN 10'OF THE POINT OF CONNECTION NEC m- e r 0 00 r DRAWN BY: JC 705.31 r--- - -- - V - =- --- --- -- ----- ...-- -- E - Ll L2 N I REVISED BY: 1M5 - - --------------- -�I 0 0 0 0 0 I 12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE A I I + --- --- UTILITY AND THE OTHER AN INVERTER,PV BACKFEED EXISTING MAIN BREAKER LOAD CENTER SQUARE DD �_17--------J System Information: BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY INSULATED LINE TAPS INSTALLED ON PN:D222NRB L-----------1 DC SYSTEM SIZE: 12.4kW NEC 705.12(B)(2)(3)(b) MAIN FEEDERS NEC 705.12(A) ACSYSTEM SIZE: lOkW 13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY MODULE COUNT: 31 GENERATION CIRCUITS AND NO UNUSED POSITIONS OR MODULES USED: HANWHA 400 LOADS MODULE SPEC#: Q.PEAK DUO BLK ML-G10.400 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE UTILITY COMPANY: PSEG-LI A NEMA 311 RATING UTILITY ACCT#: 9691115504 UTILITY METER#: 98357352 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS REQUIRED CONDUCTOR AMPACITY PER STRING DEALTYPE: SUNNOVA (NEC 690.8(6)(1)):(15.00`1.25)1=18.75A PV MODULE SPECIFICATIONS AWG#10,DERATED AMPACITY HANWHA 400(Q.PEAK DUO BLK ML-G10+400) Rev.No. Sheet AMBIENT TEMP:33'C,TEMP DERATING FACTOR:.96 RACEWAY DERATING=6 CCC:0.80 Imp 10.77 (40'.96)0.80=30.72A Vmp 37.13 NOTE:CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR (' A2 30.72A'_18.75A,THEREFORE WIRE SIZE IS VALID Voc 45.3 TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS P V �-J3 -#6 THWN-2,1-#6 THWN-2,1-#8 THWN-2 GROUND TOTAL AC REQUIRED CONDUCTOR AMPACITY Isc 11.14 A #6 THWN-2 GEC TO EXISTING GROUND ROD G 1"CONDUIT W/2 42.00A'1.25=52.50A B 1"CONDUIT W/2-#6 THWN-2,1-#10 THWN-2.1-#10 THWN-2 GROUND H 1"PVC W/2410THWN-2,14110THWN-2GROUND(TRENCHED APPROX.50') AWG#6,DERATED AMPACITY INVERTER#1-SE1000OH-USOOOBEi4C 1"CONDUITW/6-#lOTHWN-2,1-#lOTHWN-2 GROUND I 1"CONDUIT W/2-#10THWN-2,1410THWN-2 GROUND AMBIENT TEMP:30°C,TEMP DERATING:1.0 / - RACEWAY DERATING'3 CCC:N/A DC ACTrrn _ 75A'1.0=75A Imp 27 Pout 10000 D 1"CONDUITW/4-#10 THWN-2.1-#10THWN-2 GROUND ' 75A' Vmp 400 Imax 42 _52.SOA,THEREFORE AC WIRE SIZE IS VALID E 1"CONDUIT W/2-#6THWN-2,1410 THWN-2,1410 THWN-2 GROUND ItV SOLA Voc 480 OCPDmin 52.5 CALCULATION FOR PV OVERCURRENT PROTECTION ScI45 Vnom 240 F #10 PV WIRE(FREE AIR)W/#6 BARE COPPER BOND TO ARRAY TOTAL INVERTER CURRENT:42.00A -->60A OVERCURRENT PROTECTION IS VALID 2211 Allenwood Road 877-786-7293 42.00A*1.25=52.50A Wall,New Jersey 07719 www.Trinity-Solar.com MAIN ROAD* INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM cF1AE/ 2570 MAIN ROAD LAUREL NY 11948 y • :FOA 0956715 FESSIOV, r Issued/Revisions r� rI TT rI R1NAME 7/7/2022 11 "II 11 I5SU ED TO TOWNSHIP FO R PERMIT fi/23/2022 VICINITY MAP NO. DESCRIPTION DATE n�� SCALE: NTS SITE AUG 0,5 7 Project Title: STEPHEN SCHOTT BUIL '11,1G DEPS: TO�NM OF SOUTI tv�0 1 /1"S non / y + • 'rn'la-�— TRINITY ACCT#:2022-05-704679 ELECTRICAL Project Address: 1 ma-k d au4s,'de I aye led( INSPECTION REQUIRED 2570 MAIN ROAD re^ I`,/ acczSS bIs— LAUREL,96928NY 11948 iI�a ` ( 40.969282,-72.560029 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED S E ET INDEX Drawing Title: 1. THE INSTALLATION CONTRACTOR IS B. THE DC VOLTAGE FROM THE PANELS IS 14. B) CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC COMPANY SPECIFICATIONS, kCMIL THOUSAND CIRCULAR MILS EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS kVA KILO-VOLTAMPERE PV-2 ROOF PLAN W/ MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILO-WATT CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND L LINE 2. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.ONCE APPROVED,THE MCB MAIN CIRCUIT BREAKER AP APPENDIX Drawing Information RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE INSTALLATION CONTRACTOR IS MDP MAIN DISTRIBUTION PANEL EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE RESPONSIBLE FOR INSTALLING ALL MLO MAIN LUG ONLY DRAWING DATE: 6/23/2022 DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. SYSTEM COMPONENTS AS DESCRIBED IN MTD MOUNTED DRAWN BY: 1C IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR THE DRAWING PACKAGE. MTG MOUNTING COMPLY WITH ALL CODES OF REVISED BY: DMR 3. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE 16 ALL INFORMATION SHOWN MUST BE N NEUTRAL AP ROVED AS NOTED NEW YORK STATE & TOWN COD RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CERTIFIED PRIOR TO USE FOR NEC NATIONAL ELECTRICAL CODE UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE CONSTRUCTION ACTIVITIES. NIC NO# NOT IN CONTRACT AS REQUIRED AND CONDITIONS F COMPONENT AND INVERTER MANUALS ARTICLE 690&705. System Information: PRIOR TO INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS NTS NOT TO SCALE DATE: B.P.## DC SYSTEM SIZE: 12.4kW CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THE OCP OVER CURRENT PROTECTION I AC SYSTEM SIZE: lOkW ABBREVIATIONS P POLE Q01 IT`Ull n Tr11A/Al 7p q ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL FEE: �Y:,,,,�,,, (- yr Ir L„7rr� MODULE COUNT: 31 POSITION AND FUSES REMOVED PRIOR TO ATTEND A PRE-INSTALLTION MEETING AMP AMPERE PB PULL BOX THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AC ALTERNATING CURRENT PH 0 PHASE NOTIFY BUILDING Dc:-ARTMENT AT S T ❑ ^ MODULES USED: HANWHA 400 SYSTEM COMPONENTS. PROCEDURES,SCHEDULES,SAFETY AND AL ALUMINUM PVC POLY-VINYL CHLORIDE CONDUIT �- BOA D MODULE SPEC#: Q.PEAK DUO BLK ML-Gl0.a+400 4. ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. AF AMP.FRAME PWR POWER 765=1802 8 AM TO " PM FOR THE UTILITY COMPANY: PSEG-LI MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFF ABOVE FINISHED FLOOR QTY QUANTITY �7�i i�RtJSTEES CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL AFG ABOVE FINISHED GRADE RGS RIGID GALVANIZED STEEL FOLLOWING INSPEC i IONS: vL UTILITY ACCT q: 9691115504 ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL AWG AMERICAN WIRE GAUGE SN SOLID NEUTRAL 1. FOUNDATION - TWO REQUIRED UTILITY METER#: 98357352 SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC WIRING C CONDUIT (GENERIC TERM OF JSWBD SWITCHBOARD •J�I1 DEALTYPE: SUNNOVA COURSE ON SITE. CONDUCTIVITY CHECKS. RACEWAY,PROVIDE AS TYP TYPICAL FOR POURED CONCRETE I O.. UNLESS OTHERWISE INDICATED 5. FOR SAFETY,IT IS RECOMMENDED THAT 12. FOR THE PROPER MAINTENANCE AND SPECIFIED) U. 1 � 71 THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CB COMBINER BOX WP WEATHERPROOF .2. ROUGH - FRAk/ING & PLUMBING MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CKT CIRCUIT XFMR TRANSFORMER (/� TOGETHER AND THAT EACH OF THE OPERATION MANUAL. CT CURRENT TRANSFORMER +72 MOUNT 72 INCHES TO BOTTOM 3. INSULATION OCCUPANCY OR Rev.No. Sheet INSTALLATION CREW MEMBERS BE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC CU COPPER OF ABOVE FINISHED FLOOR OR 4. FINAL COTr'.l I7j,Q1 MUST IN FIRST AID AND CPR. AND TELEPHONE UTILITIES ARE SUBJECT DC DIRECT CURRENT GRADE USE IS UNLAWFUL R 1 PV 1 6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF THE DISC DISCONNECT SWITCH BE COMPLE�I� :`;. 0. BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND DWG DRAWING ALL CONSTRUC i ICf� SHALL MEET THE CONVENTIONSELECTRICAL CODE.THE ANY LOCAL OWNERS. EC ELECTRICAL SYSTEM INSTALLER WITHOUT C E RTI FI C� ELECTRICAL CODE. ANY LOCAL CODE 14. ALL MATERIALS,WORKMANSHIP AND EMT ELECTRICAL METALLIC TUBING REQUIREMENTS OF THE CODES OF NEW WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION FOR THE SITE FS FUSIBLE SWITCH /� GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL FU FUSE YORK STATE. NOT RESPONSIBLE FOR OF OCCUPANCY 0 7. ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH: GND GROUND INSTALLED WITH THIS SYSTEM ARE TO BE A) CURRENT PREVAILING MUNICIPAL GFI GROUND FAULT INTERRUPTER DESIGN OR CONSTRUCTION ERRORS. ,� "UL"LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, HZ FREQUENCY (CYCLES PER 3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS SECOND) / GENERAL NOTES SOLAR IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT. 2211 Allenwood Road 877-786-7283 Wall,New Jersey 07719 www.Trinity-Solar.com NOTES:'REFER TO MODULE SPECS FOR MODULE DIMENSIONS 'DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE ECOFASTEN CLAMP NEW PV SOLAR MODULE,TYPICAL (REFER TO SPEC SHEET FOR DETAILS) (REFER TO EQUIPMENT SCHEDULE FOR SPECS AND QUANTITIES) SOLAR MODULE SOLAR MODULE ♦ _ NEW MOUNTING FOOT/ATTACHMENT \ POINTS,TYPICAL (REFERTO ECOFASTEN"L"FOOT ECOFASTEN RAIL l5 PO ENGINEERING LETTER FOR SPACING (REFER TO SPEC SHEET FOR DETAILS) (REFER TO SPEC SHEET FOR DETAILS) .� / AND DETAILS) 'o 9 c ^' NEW ECOFASTEN RAIL,TYPICAL__T N �`� Q r 'v TO BE MOUNTED PERPINDICULAR TO EXISTING ASPHALT SHINGLES ECOFASTEN FLASHING — — �CH�'E� STRUCTURE(REFERTOECOFASTEN `� �pn O SPECIFICATION I DATA SHEET FOR (REFER TO ENGINEERS LETTER FOR SPECS) (REFER TO SPEC SHEET FOR DETAILS) G-'` -11' H2O✓ A DETAILS) NEW END CLIP,TYPICAL S.S.LAG BOLT— NEW SEALANT _♦ __ _♦ (REFER TO ECOFASTEN SPECIFICATION (REFER TO ENGINEERS LETTER FOR SPECS) SOLAR MODULES SHALL NOT /DATA SHEET FOR DETAILS) EXISTING RAFTER EXCEED PEAK HEIGHT. w NEW MID CLIP,TYPICAL (REFER TO ENGINEERS LETTER FOR SPECS) _ > (REFER TO ECOFASTEN SPECIFICATION /DATA SHEET FOR DETAILS) © 09-6 5 C1 ATTACHMENT&CLIP DETAIL nPV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF nHEIGHT FROM GROUND LEVEL TO PEAK OF ROOF ,p 67 SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE ;90'cESS L0,`PV ARRAY SCHEDULE Issued/Revisions Rl NAME 7/7/2022 PS ISSUED TO TOWNSHIP FOR PERMIT 6/23/2022 NO. DESCRIPTION DATE [DC D AC Project Title: M (CONDUIT TO BE TRENCHED APPROX.60 FEET) R4 R3 STEPHEN SCHOTT TRINITY ACCT N:2022-05-704679 Project Address: LU 2570 MAIN ROAD R6 LAUREL,NY 11948 <a y _ 40.969282,-72.560029 ]. Y Uj LL � R1 m Drawing Title: OJE _`€`t€€ - _ = PROPOSED PV SOLAR SYSTEM e=tt ----- ------ - 7 Drawing Information R7 =Ett EE mill _E€t€ _ €EtE = €e�t����t`, e�t� DRAWINGDATE: 6/23/2022 tttDRAWN BY: 1C REVISED BY: DMR ttttL --- -tt,`. - - --t ttt � � • System Information: DC SYSTEM SIZE: 12.4kW et��rl E _-"t`L _ `tom` - `- ���� AC SYSTEM SIZE: SOkW R2 = MODULE COUNT: 31 MODULES USED: HANWHA 400 MODULE SPEC#: Q.PEAK DUO BLK ML-G10.a+400 UTILITY COMPANY: PSEG-LI ROOF 1 UTILITY ACCT#: 9691115504 MODULES:0 NOTES: PITCH:40° UTILITY METER#: 98357352 ORIENTATION:61° 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE DEAL TYPE: SUNNOVA ROOF 2 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. MODULES:19 2.) ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. PITCH:40 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ORIENTATION:241 Rev.No. Sheet 4.) AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S) NEC 690.13(E) ROOF 3 5) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. MODULES:12 PITCH: 6.) ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. ORIENTATION:151 ROOF4 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE Pvj- 2 MODULES:0 QTY SPEC# ORIENTATION:331° R� INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE SP INDICATES NEW PV ONLY SUBPANEL �ij ARRAY SCHEDULE FOR MORE INFORMATION UD INSTALLED OUTSIDE (UTILITY ACCESSIBLE) TO BE INSTALLED 31 HANWHA 400(Q.PEAK DUO BLK ML-G10.a+400) ROOF MODULES:0 PITCH:34° INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SE1000OH-USOSHBNC4 ORIENTATION:331° M INDICATES EXISTING METER LOCATION INDICATE PANELS THAT USE MICRO INVERTERS. pC INDICATES NEW DC DISCONNECT I Q ROOF 6 REFER TO EQUIPMENT SCHEDULE FOR SPECS. MODULES:0 OTHER OBSTRUCTIONS � T r PITCH:34° INDICATES EXISTING ELECTRICAL PANEL INDICATES NEW PRODUCTION METER TO BE ORIENTATION:61° EP LOCATION: IN BASEMENT P INSTALLED OUTSIDE. Sp INDICATES EXISTING SERVICE DISCONNECT S OLA R ROOF MODULES:0 PITCH:34° IBLE)NDICATES NEW FUSED PV DISCONNECT TO BE INDICATES NEW INVERTER TO BE ORIENTATION:241° INSTALLED OUTSIDE(UTILITY ACCESSIINSTALLED OUTSIDE. TS INDICATES EXISTING TRANSFER SWITCH 2211 Allenwood Road 877-786-7253 A REFER TO EQUIPMENT SCHEDULE FOR SPECS Wall,New Jersey 07719 www.Trinity-Solar.com Engineer/License Holder: ARRAY CIRCUIT WIRING NOTES SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS 1. LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY 31-40OW MODULES W/1 SOLAR EDGE 5440 PER MODULE FOR DETERMINING ONSITE CONDITIONS AND 15 ADC MAX PER STRING EXECUTING INSTALLATION IN ACCORDANCE WITH (TOTAL) NEC 2017 _ 1 STRING OF 9 MODULES IN SERIES-400 Vmax 1 STRING OF 10 MODULES IN SERIES-400 Vmax G 2.j LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON �` 0 ASHRAE MINIMUM MEAN EXTREME DRY BULB i STRING OF 12 MODULES IN SERIES-400 Vmax �� C�`C E(�0 TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO '3 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 Gj INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT --- ------ 8x8 --------------------------------------- ------ �b P CIG TEMP=-16°C (HOUSE) JUNCTION 1 1 STRING OF 9 MODULES IN SERIES-400 Vmax BOX D I 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED 1 STRING OF 10 MODULES IN SERIES-400 Vmax I (r, '2 STRING TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 e e e e e e_ I {*1 r W ON ASHRAE HIGHEST MONTH 2%DRY BULB - - TEMPERATUREFORASHRAELOCATIONMOSTSIMILARTO I- -1 INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= (GARAGE) ___ ______ 8"x8" __________ ________ I I 1 6"x6" ---- 33"C i STRING OF I2 MODULES IN SERIES-40OVmax JUNCTION JUNCTION 1 GA 05.5675 '1 STRING TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 F BOX I I BOX I 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN 1 RO/�ESSIO TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES(PALM SPRINGS,CA IS 44.1°C). FOR LESS THAN 9 DC DISCONNECT 1 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED 1 Issued/Revisions SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING I THE OUTDOOR DESIGN TEMPERATURE OF 47"C OR LESS I (ALL OF UNITED STATES) I I 5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS I R> NAME 7/7/2022 SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT I CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I Pl ISSUED TO TOWNSHIP FOR PERMIT 6/23/2022 NEC 690.12(A)THROUGH(D) I NO. DESCRIPTION DATE I 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED I TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC 1 Project Title: I SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4) 1 STEPHEN SCHOTT 7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE I IDENTIFIED WITH THE FOLLOWING OUTER FINISH: I TRINITY ACCT#:2022-05-704679 POSITIVE CONDUCTORS =RED NEGATIVE CONDUCTORS=BLACK EXISTING240V 10 NOTE: I NEC 210.5(C)(2) 10 120/240V R 200A MAIN BREAKER INTERNAL REVENUE GRADE MONITORING 1 Project Address: UTILITY METER 200A BUSBAR CONTAINED WITHIN SOLAR EDGE INVERTER I 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV SOLAR EDGE PN.RWND-3D-240-MB WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE 2570 MAIN ROAD PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT LAUREL,NY 11948 SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24"SHALL I CONTAIN 5 20 CURRENT CARYING CONDUCTORS AND s 40.969282,-72.560029 WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN<_ 9 CURRENT CARRYING CONDUCTORS. 1 1 Drawing Title: 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS LOCKABLE 60A DISCONNECT INVERTER#1 OTHERWISE NOTED FUSED W/60A FUSES l/+_ 10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON 240V 10 PROPOSED PV SOLAR SYSTEM ROOFTOP AND SHALL BE LIMITED TO 12"IF USED 0 a eye e e a + OUTDOORS r --- 0 I I 11.)OVERCURRENT PROTECTION FOR CONDUCTORS0 I Drawing Information CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE e e I �^ -- a 0 _-J DRAWING DATE: 6/23/2022 LOCATED WITHIN 10'OF THE POINT OF CONNECTION NEC e L w e J� _ C Ll L2 N 0 r DRAWN BY: JC r--- 705.31 --_-_-_ e 17 C o e o e e e - - - - --------------- ----I 000 0 0 REVISED BY: DMR 12.)WHERE TWO SOURCES FEED A R,ONE A UTILITY AND THE OTHER AN INVERTERER,,PV PV BACKFEED EXISTING MAIN BREAKER LOAD CENTER SQUARED I U L��--------J BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY INSULATED LINE TAPS INSTALLED ONPN:D222NR6 I I System Information: NEC 705.12(B)(2)(3)(b) MAIN FEEDERS I---------J DC SYSTEM SIZE: 12.4kW 13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY NEC 705.12(A) AC SYSTEM SIZE: 10kW GENERATION CIRCUITS AND NO UNUSED POSITIONS OR MODULE COUNT: 31 LOADS MODULES USED: HANWHA 400 MODULE SPEC it: Q.PEAK DUO BLK ML-G10.a+400 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3R RATING UTILITY COMPANY: PSEG-LI UTILITY ACCT#: 9691115504 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER M 98357352 REQUIRED CONDUCTOR AMPACITY PER STRING DEALTYPE: SUNNOVA [NEC 690.8(8)(1)1:(15.00'1.25)1=18.75A PV MODULE SPECIFICATIONS AWG#10,DERATED AMPACITY HANWHA 400(Q.PEAK DUO BLK ML-G10.a+400) AMBIENTTEMP:33°C,TEMP DERATING FACTOR:.96 Rev.No. Sheet RACEWAY DERATING=6 CCC:0.80 Imp 10.77 (40*.96)0.80=30.72A Vmp 37.13 NOTE:CONDUITTYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS R 1 PVJ- 3 30.72A'_18.75A,THEREFORE WIRE SIZE IS VALID Voc 45.3 TOTAL AC REQUIRED CONDUCTOR AMPACITY Isc 11.14 A #6 THWN-2 GEC TO EXISTING GROUND ROD G 1"CONDUIT W/2-#6 THWN-2,146 THWN-2,148 THWN-2 GROUND 42.00A'1.25=52.50A B 1"CONDUIT W/2-#6THWN-2,1410THWN-2,1410THWN-2 GROUND H 1"PVC W/2410THWN-2,1-#30THWN-2GROUND(TRENCHED APPROX.50') AWG#6,DERATED AMPACITY INVERTER#1-SE1000OH-USOSHBNC4 C 1"CONDUIT W/6410 THWN-2,1410 THWN-2 GROUND I 1"CONDUIT W/2410THWN-2,1410 THWN-2 GROUND AMBIENT TEMP:30°C,TEMP DERATING:1.0 RACEWAY DERATING`-3 CCC:N/A DC AC 0 75A`1.0=75A Imp 27 Pout 10000 D 1"CONDUIT W/4-#1OTHWN-2,1410THWN-2 GROUND 75A'_52.50A,THEREFORE AC WIRE SIZE IS VALID Vmp 400 Imax 42 E 1"CONDUIT W/2-#6 THWN-2,1-#10 THWN-2,1-#10 THWN-2 GROUND Tri Voc 480 OCPDmin 52.5 SOLAR CALCULATION FOR PV OVERCURRENT PROTECTION F #10 PV WIRE(FREE AIR)W/#6 BARE COPPER BOND TO ARRAY TOTAL INVERTER CURRENT:42.00A Isc 45 Vnom 240 42.00A'1.25=52.50A 2211 Allenwood Road 877-786-7283 -->60A OVERCURRENT PROTECTION IS VALID Wall,New Jersey 07719 www.Trinity-Solar.com Q Doi Eco' Fasten, For InstaLlers. By Installers. COMPLETE RAIL-BASED RACKING SYSTEM ClickFit is one of the fastest installing rail-based systems in the industry. Thanks to its Click-In rail assembly,the Composition Shingle, Tile,Metal rails can be connected to any of EcoFasten's composition shingle, tile, and metal roof mounts in seconds.without the need for fasteners or tools. The ClickFit system is made of robust materials such as aluminum and coated :::: Rail-Based steel, to ensure corrosion-resistance and longevity. ClickFit conforms to UL 2703 and has been tested in - - extreme weather conditions including wind,fire, and snow. Structural-Attach FEATURES & BENEFITS Direct-Attach • Tool-less,fastener-free rail attachment • Fully integrated bonding • Click-On Mid&End Clamps • Compatible with a variety of EcoFasten roof attachments )25 YEAR WARRANTY( FAST INSTALLING SYSTEM FEATURING CLICK-IN RAIL ASSEMBLY ` - INTERNAL SPLICE Tool-free bonded internal Splice installs in seconds. MLPE MOUNT Attach Module Level Power 4; y s MID CLAMP Electronics to the top of the rail. Click-on mid clamp features integrated bonding pins and fits modules 30-50 mm in width. END CLAMP Click-on end clamp fits modules ENO C A P 30-50mm in width. The slide-on end caps allow the end clamps to be accurately positioned on the rail in seconds, while providing an aesthetically- pleasing, finished install. E L- FOOT The ClickFit rail simply clicks into our proprietary composition - shingle & the L-foot without the need to use fasteners or tools. COMPOSITION SHINGLE Combine the versatile ClickFit L-Foot with the watertight GF-1 flashing for a fast installation on composition �. shingle roofs. GF-1 FLASHING&L-FOOT TILE ROOFS Use the adjustable ClickFit Tile Hook for attaching the ClickFit Ria system to tile roofs. Works with Flat, S, and W the profiles. , CLICKFIT TILE HOOK STANDING SEAM .METAL ROOFS Combine the ClickFit L-Foot with SimpleBlock°-U for a , . -- fast installation on standing seam metal roofs. o' i SIMPLEBLOCK-U �. PRODUCT PART PART BOX PALLET IMAGE NUMBER DESCRIPTION QUANTITY QUANTITY ASSEMBLED WITH(1)OF GROMMET AND INCLUDES(1)5/16'EPOM BONDED WASHER 131"1M-GAL-BLK-810 GF1 8X10"ELK GLV 50 3200 W/2"HL PLCMT - GF1-GAL-BLK-812 GF1 8X12"GALVALUME ELK 50 2600 FLASHING ALL HARDWARE INCLUDED WITH •• 1500004 CF L-FOOT ASSY 100 5000 (NO HARDWARE NEEDED) 1500005 CF TILE HOOK US 20 480 u ~ - 1510045 CF TILE HOOK SUB-FLASHING 20 2160 TILE HOOK FLSH F ST TILE HOOK FLASH12 576 FIAT SIERRA TAN TILE HOOK FLSH-W ST TILE HOOK FLASH 12 576 W SIERRA TAN TILE HOOK FLSH-S ST TILE HOOK FLASH 12 576 S SIERRA TAN SIMPLEBLOCK-U-AL 2"SIMPLEBLOCK SSR-AL 25 4400 a ALL HARDWARE INCLUDED WITH •, 1500004 CFL-FOOT ASSY 50 5000 (NO HARDWARE NEEOEO] 1500033 CF RAIL 2130MM N/A 108 (-7 FT) 1500034 CF RAILN/A 108 FTI (-10,4 FT] 1500035 CF RAIL 8 FT) N/A 108 (-13.8 Fn i•''� 1008051 CF RAIL SPLICE 100 3200 1510070 CF WIRE MGMT CLIP 1000 TBD 1500028 MODULE JUMPER,8 IN 25 25000 5 [204MM) ��? 1510057 CF MLPE MOUNT 400 17600 PRODUCT PART PART BOX PALLET IMAGE NUMBER `, DESCRIPTION QUANTITY QUANTITY 1510041 OF ENDCAP,BLK LABELED 100 4800 1510015 OF HD ENDCLAMP 20 5500 30MM,BLK " 1510016 OF 32MMOB�KMP 50 5600 1510017 OF HO ENDCLAMP 50 5600 35MM,BLK 1510018 OF HO ENDCLAMP 50 5600 38MM,BLK 1510019 OF HD k40MM,B LK 50 5600 1510020 OF HD A45MMOB KMP 50 5600 1510011 OF HO MIOCLAMP 50 5600 30-40MM,BLK 1510012 OF HD MIOCLAMP 50 5600 y 40-50MM,BLK i ROCK-IT V3 SKIRT A65 ROCK-IT SKIRT V3 8 256 35MM&40MM 66" ROCK-IT V3 SKIRT A79 ROCK-IT SKIRT 8 256 35MM&40MM 79 79" ROCK-IT V3 SKIRT A80 ROCK-I& SKIRT V3 voppppp 35MMM SKIRT 80" 8 256 ROCK-IT V3 SKIRT B55 32MM R SKIRT V3 8 256 && SKIRT 65" ROCK-IT V3SKIRT 879 ROCK-IT SKIRT 79 8 256 vpppopp 32MM&38MM 79" ROCK-IT V3 SKIRT B80 ROCK-IT SKIRT V3 8 256 32MM&38MM 80 Nam 1500003 OF UNIVERSAL SKIRT 50 5750 CLAMP BLK �!0 POLY KIT LAG SCREW 4 POLY KIT LAG 50 480 SCREW 4"(50) SCRW OP 15-13X03 ROOFING SCRW 1000 60000 #15 X 3"DRILL PT INCLUDES :O � _. 1510001 CONDUITMOUNT-BRKT 50 10350 INCLUDES(1)SS B-18 X 3/4"TEK SCREW CONOUITMOUNT-TILE CONDUIT MOUNT-TILE SYSTEM 60 4320 i Y .,j* J`��•~i�Y;, � t..1i1S'S�j� ryb' JJis�s h iI 211M 111 i�11 q. ir,. -!i I�•��'( �4=9..f� �' ��'/° ,1 I. "" �.r�':. may, t �T��S r '� -J - :»:. .,$.,- -- - ; _ tea.•ti���i'�.:�3t�"" _ e �. - _ ..�Y. :til._ - �':•a.•v-� yap�_4' ,�:'-�:0"9'' _�:'—.__-� .�-s�r:�r_'�'_ �tlf:.2 + pry; '�.,iti'2+ '.1 ` !.moi•., f7'? r. ,p;.:� , :�.<� :;�,�. _� x' �J `�iY`<n :i"7 ✓"'�,.�'' .%';.`.-.i'S �� '�_�'r,�{as:¢y,� M z.,N�'.�`'r.\,.y*n _ �•' ; ,k- 's �yy-.>;'t `•urs,a-.1 �1. .S.�t, 'Y.i.�• -� �� ,'ku dT ,�f� � ;i,,�,{ri,$��." wt�,n.�,;• ;v+t�i '�s��.�+a'.�.;w" :.,�i�,+f.� _.'�. �" (.� •,f S,a1 �;.4.. � iiS"i{'he� � �.4 ., 1.i.:f•d" :Y.h�..Ful""i'.FX.• ,yti F•9� �_ tAk' iaY,fi��i�µ.. .ar � n. "'--»�)))< r f� v1$'.zl.. J�r�. ,�n'.��',^`�f•�� -'Sroy y+J. ,`:�'=d ,t,+_',� "� 3v R' •.. ��r a" '�a� ��:�' s. 'x ''�^-�.14��.;38✓i�:ci 'u'. ' 4,,iy. ��+y .:s-� •.rte`�z?�c;•��'' ECOFASTEN SOLAR EcoFasten has an established a reputation for being one of the industry's leading innovators by providing expert solutions for mounting solar PV on any type of roof. Our broad portfolio of solutions stem from the needs of, and direct inputs by solar PV installers. We take pride in providing the right solution for every application. We educate our customers, so they purchase the best, most cost-effective solutions to fit their needs, and we complement that with on- site installation training to ensure 100% satisfaction. We are honest with ourselves, our customers, and our employees, fostering a culture of idea-sharing, innovation, and creativity. 4141 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009 � yEcoFasten An ESDEC Company 1 - 877 - 859 - 3947 INFO@EC0FAS TENS0LAR.00M ' Single Phase Inverter Z • HD-Wave 'TechhologyC with m for North America X SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE10000H-US / SE1140OH-US , m 70 Ln o ®l i 1 solar=- .w!if.woe ' solar l 13wo, j i r } t o" Optimized installation with HD-Wave technology / Specifically designed to work with / UL1741 SA certified,for CPUC Rule 21 grid compliance power optimizers / Record-breaking efficiency / Extremely small / Quick and easy inverter commissioning directly / guilt-in module-level monitoring from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article / Optional: Revenue grade data,ANSI C12.20 690.11 and 690.12 Class 0.5 (0.5%accuracy) solaredge.com solar ® @ �' ® Single Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.S(l) Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V Power Factor 1,adjustable-0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240W- 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208W� - 9 13.5 - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption <2.5 W For other regional settings please contact SolarEdge support A A higher current source may be used;the inverter will limit its input current to the values stated • a L / Single Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional`l Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi Access Point for local connection Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety 1-111741,UL1741 SA,1-11169913,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG Range DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG V Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ (HxWxD) mm Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38.8/17.6 Ib/kg Noise <25 <50 dBA Cooling Natural Convection- Operating onvectionOperating Temperature Range -40 to+140/-40 to+%-" Protection Rating NEMA 4X(Inverter with Safety Switch) 01 Revenue grade inverter P/N:SExxxxH-1JS000BNC4 "I Full power up to at least 50'C/122'F,for power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Q SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc All Ro H S other trademarks mentioned herein are trademarks of their respective owners.Date:5/2019N01/ENG NAM.Subject to change without notice. povyered by SVD t �• � YR ® Q t-TOP BRAND PV EUROPE �, Warranty 2021D CELLS a.,]W6Pe11w nce Yield Security BREAKING THE 2054,EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY (y: Optimal yields,whatever the weather with excellent low-light and temperature behavior. _ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect and Traceable Quality Tra.QT"'. EXTREME WEATHER RATING QU// High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). � cc,�Z A RELIABLE INVESTMENT� 7 Inclusive 25-year product warranty and 25-year linear performance warrantyz. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) 'See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany CELLS MECHANICAL SPECIFICATION Format 74.0 in x 41.1 in x 1.26 in(including frame) (1879 mm x 1045 mm x 32 mm) 42 a'(109amm) 15.6'(3955 mm) Weight 48.5lbs(22.0kg) Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology 4+Gmun4ing W- 018'(4.5 Frame Back Cover Composite film 39.T 1996mm) Frame Black anodized aluminum ® 41.1-t1o4s„J Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60 mm x 15-18 mm),IP67,with bypass diodes ehB1� :49s(z50m,J Cable 4mm'Solar cable;(+)>-49.2in(1250mm),(-)>-49.2in(1250mm) a+-h­ 4 M-9-(DML i hF 4+M-9-(DML A) Connector Staubli MC4;IP68 I I 136'(31 mm) DEAILA 0.63'(16,,) I 0.96'(245mm)I- !am.(a 5mm) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-0 W) Power at MPP' PMPP [W] 385 390 395 400 405 Short Circuit Current' [A] 11.04 11.07 11.10 11.14 11.17 E E Open Circuit Voltage' Vcc [V] 45.19 45.23 45.27 45.30 45.34 Current at MPP 6P [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VMpp [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' 9 [%] >_19.6 >-19.9 >-20.1 >_20.4 220.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT3 Power at MPP P.pP [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Vcc [V] 42.62 42.65 42.69 42.72 42.76 E Current at MPP I-P [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMPP [V] 34.59 34.81 35.03 35.25 35.46 1Measurement tolerances PMPP±3%;Isc:Voc±5%at STC:10DOW/m1,25±2°C,AM 1.5 according to IEC 60904-3•'800 W/mz,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE I a':° At least 98%of nominal power during =sW first year.Thereafter max.0.5% z Wm I I It 0 ------------------- -------- degradation per year.At least 93.5% ,00 ------------i-- ' W of nominal power up to 10 years.At z least 86%of nominal power up to .- w g0 '° 25 years. r .0-----------------------------� z ° e All data within measurement toleranc- ° ° no w as.Full warranties in accordance with 100 400 n.D Sao woo o the warranty terms of the O CELLS o o , sales organisation of your respective IRRADIANCE[W/m+l o ° ° 21 country. YEARS Typical module performance under low irradiance conditions in o cwo ��wmce comparison to STC conditions(25°C,1000W/M2) TEMPERATURE COEFFICIENTS Temperature Coefficient oflsc a [%/K] +0.04 Temperature Coefficient of VDD [i [%/K] -0.27 Temperature Coefficient of Pmpp y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) m 0 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VS,.s [V] 1000(IEC)/1000(UL) PV module classification Class II o N Maximum Series Fuse Rating (A DC] 20 Fire Rating based on ANSI UL 61730 TYPE 2 W Max.Design Load,Push/PUII3 [Ibs/ft1] 75(360OPa)/55(266013a) Permitted Module Temperature -40°F up to+1857 o Max.Test Load,Push/PUII3 [Ibs/ft1] 113(540OPa)/84(4000Pa) on Continuous Duty (-40°C up to+85°C) 3See Installation Manual U QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION ///��� /� 0 UL61730,CE-compliant, I�/N f�lYl Ib 53•n O m Quality Controlled PV-TUV Rheinland, Llh a lLll� O"-O-J I40;HCI n IEC 61215:2016,IEC 61730:2016, / m U.S.Patent No.9,893,215 iso ® ♦ mveSam,�e Horizontal 76.4in 43.3 in 48.Oin 1656lbs 24 24 32 lar cells), s� OCPV Certification ongoing. Cc4rml°e US ` packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules -_ UL 61]30 ID 111]]0T] Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha a CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us NOTES: 1.)COMPUES WITH NEC 2017 2.)REFER TO SHEET PV-3 FOR SITE SPECIFIC VALUES REQUIRED BY NEC 690 3.)STICKERS,LABELS,AND PLACKARDS SHALL BE OF SUFFICIENT OURRABILITY TO WITHSTAND THE ENVIROMENT INVOLVED • • To be located anal]DC junction boxes SOLAR PV SYSTEM EQUIPPED and every 30'on DC conduit WITH RAPID SHUTDOWN ,fir• ;• • - S4 OLAR NEC 690.31(G) •'�•' NEL 690.56(C)(1)IA) DC Junction Box -• • •• • «r. 690.56(C)(3) NEC 690.4(B) f Service D6connect • ,NEC 690.13(8 NEC 690.53. • 690.56(Q(3) Soladeck SOLAR PV SYSTEM EQUIPPED Utility • • • WITH RAPD SNUTDONT7 c ,•�0bt,,, '� • 1 • � �;• —__.F l ' NEC 690.4(8) NEC 690.13(8) NEC 690.56(C)(1)(A) If System is Backfed Breaker NEC 690.54 NEC 690.53 NEC® DC Disconnect NEC 690.54 r Utility Meter Socket µNEC 690.13(8) NEC 690.54 l _ •NEC 690.13(B) a / 7-1111111" 'ql /11 DC Conduit Main Service Panel Solar Meter Socket PhotovoltalcLoad Center Inverter(s) Enphase Envoy Box AC Disconnect (To Combine Inverters)