Loading...
HomeMy WebLinkAbout48318-Z `OSUFfal,�cpr Town of Southold 5/5/2023 jo Gyp t P.O.Box 1179 53095 Main Rd oy�j0 ao� ' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44071 Date: 5/5/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2570 Route 25,Laurel SCTM#: 473889 Sec/Block/Lot: 125.-3-3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/5/2022 pursuant to which Building Permit No. 48318 dated 9/21/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as aapplied for. The certificate is issued to Schott, Stephen of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48318 4/5/2023 PLUMBERS CERTIFICATION DATED Autorize ignature o�SUFFo TOWN OF SOUTHOLD a� aye BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • � SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48318 Date: 9/21/2022 Permission is hereby granted to: Schott, Stephen 2570 Main Rd Laurel, NY 11948 To: construct roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: - 2570 Route 25, Laurel SCTM #473889 Sec/Block/Lot# 125.-3-3 Pursuant to application dated 8/5/2022 and approved by the Building Inspector. To expire on 3/22/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector OF SO(/T�ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(5-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Stephen Schott Address: 2570 Route 25 city:Laurel st: NY zip: 11948 Building Permit#: 48318 &48319 Section: 125 Block: 3 Lot: 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Trinity Solar License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 12.4kW Roof Mounted PV Solar Energy System w/ (31) 40OW Modules, DC Disconnect, Inverter, AC Disconnect Notes: Solar Inspector Signature: Date: April 5, 2023 S.Devlin-Cert Electrical Compliance Form 00, g SOUTyO� �� -- ZS7 0 e+-Z-5 * # TOWN OF SOUTHOLD BUILDING DEPT. cou631.765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: t4,Fef!lV2 JC- DATE INSPECTOR pF SOUTyOlo # # TOWN OF SOUTHOLD BUILDING DEPT. courm��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ��FAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: I �� 0 c.- DATE 'a - o? INSPECTOR SOLAR Southold Town, NY December 5, 2022 Town Hall Annex Building54375 Route 25 P.O. Box 1179 Southold, NY 11971 RE: STEPHEN SCHOTT Trinity Solar No. 2570 MAIN RD 2022-05-704679 LAUREL, NY 11948 To the Building Official: I hereby certify that I am a Licensed Professional Engineer in the State of New York. The solar photo-voltaic(PV) system installed at the above-referenced location conforms to the manufacturers' requirements/specifications. The PV system complies with all applicable laws, codes and ordinances as specified by all applicable codes, including 2020 Residential Code of New York State and the 2018 IRC, and the provisions of ASCE7-16. Regards, Thor Bojcun, PE Structural Engineer-Trinity Solar `•L r C `1 r JF NY License No.095675 Trinity Solar 12180 5th Avenue,Unit 1 1 Ronkonkoma,NY 1(631)319-7233 FIELD INSPECTION REPORT I DATE COMMENTS `o FOUNDATION (1ST) a ------------------------------------ O tC FOUNDATION (2ND) ' 9 z 900 y N ROUGH FRAMING& PLUMBING -3��.•'�� ,,`,,ll ' � W r INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS V� l -�3 en ass a� e uo f- b 0 z x Z� � x d b H r:z�>xp ufFotK�o TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.jzov f Y��ry Date Received APPLICATION FOR BUILDING PE MIT For Office Use Only 3 � PERMIT N0. Building Inspector: Applications and forms must be filled out in their entirety.Incomplete AUG 0 5 2022 L applications will not be accepted. Where the Applicant is not the owner,an BUILDING DEPT* U, Owner's Authorization form(Page 2)shall be completed. TOWN OF souTHOI O, Date:7/08/2022 OWNER(S)OF PROPERTY: Name:Stephen Schott_ ". SCTM#"1000-125.00-03.40-003.000 . Project Address: 2570 Main Road, Laurel, NY 11948 ---------- Phone#~(631") 478-9623_ _ . Email:kristi.sarog_lou@gmail.com _ Mailing Address:2570 Main_ Road, ~Laurel, NY 11948_._._.-._.._..__..___�__.___".._.__...____..__ CONTACT PERSON: Nam11 e: Samuel Magliaro _ __.-- MailingAddress:2180 5th Ave Unit_ 1 , Ronkonkoma,_NY 1.1779 Phone#:(631) 319-7233_._ _ Email:Brittany_Gaumer@trinity-solar.com DESIGN PROFESSIONAL INFORMATION: Name: lhor_Bojcurl _._-_____._..____.____..._.__...___________�___.____.- Mailing Address:"105 Way point Drive, Eatontown, eNJJ 07724 Phone#: 631-319-7233 _ . _ Email_ Ihor.Bojcun@trinity--solar.com CONTRACTOR INFORMATION: Name^Trinity Solar-Samuel_Magliaro.-___.. Mailing Address:21805th Ave.Unit 1 . Ronkonkoma. NY 11779,_ Phone#:(631)_319-7233 __. Email Brittany.Gaumer@trinity-solar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: Fol Other Installation of Hanwha 400 solar panels, kW $53, 835.02 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ❑No " 1 PROPERTY INFORMATION Existing use of property: intended use of property: .......... Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. R Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. I Application Submitted By(prill name):Samuel Magliaro PAuthorized Agent ElOwner Signature of Applicant: Date: -7/S STATE OF NEW YORK) SS: COUNTY OF Samuel Magliaro being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Agent (Contractor,Agent,C&porate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and,to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth.in the application file therewith. Sworn before me this day of 20;?& N&dry Public BRITTANY GAUMER NOTARY PUBUC,STATE OF NEW YORK PROPERTY OWNER AUTHORIZATION - NO. 01GA6428115 QUALIFIED IN SUFFOLK COUNTY (Where.the applicant is not the owner) MY COMMISSION EXPIRES JAN 10,2026 Stephen Schott residing at2570 Main Road, Laurel, NY 11948 do hereby authorize Samuel Magliario to apply on my behalf to a own of Southold Building Department for approval as described herein. Owe r"s'-Signature Date Stephen Schott Print Owner's Name 2 BUILDING DEPARTMENT-Electrical In`sp°eAUG 0:5 TOWN OF SOUTHOLD T� �ING c `} ,t Town Hall Annex - 54375 Main Road - PO Box 1" Fs0U­Hoio 5. Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ro err _southoldtownny.gov seand(cr� outholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 7/08/2022 Company Name: Trinity Solar Name: Richard Guaneri License No.: ME-57843 email: Brittany.Gaumertrinit -solar.com Address: 2180 5th Ave Unit 1 Ronkonkoma NY 11779 Phone No.: (631) 319-7233 JOB SITE INFORMATION (All Information Required) Name: Stephen Schott Address: 2570 Main Road, Laurel, NY 11948 Cross Street: Franklinville Road Phone No.: 631 478-9623 Bldg.Permit#: email: kristi.sarogiou@gmail.com Tax Map District: 1000 Section:12500 Block: 0300 Lot: 003000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of a utility approved, grid inter-tied, flush mount, roof mounted, 31 Hanwha 400 solar panels, 12.4kW,_photo_voltaic electricity generating system. Circle All That Apply: Is job ready for inspection?: YES NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: . A #Meters Old Meter# . New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 02��'7j Imo'" 0 Request for Inspection Formals 9 P 1 tJEW Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured TRINITY SOLAR INC. Contractor ID 612990 2180 FIFTH AVENUE, UNIT 1A 631-319-7233 RONKONKOMA, NY 11779 Work Location of Insured(Only required ifcoverage is specifically limited to 1 c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 22-3292324 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Standard Security Life Insurance Company of New York Town of Southold 3b.Policy Number of Entity Listed in Box 1 a 54375 Route 25 R71757-000 Southold,NY 11971 3c.Policy Effective Period 7/1/2013 to 6/1/2023 4. Policy provides the following benefits: ❑X A.Both disability and Paid Family Leave benefits. B.Disability benefits only. C.Paid Family Leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as descr' d above. Date Signed 6/2/2022 By '"' (Signature of insurance carrier's authoriled representative or NYS licensed insurance agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT:lf Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 413,4C or 56 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers' Compensation Board, the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers' Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 11111111111111111111°1°°1°1°1°°°°°1111°1111111 Additional Instructions for Form 13113-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1 a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law.The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage (Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c, whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand and twenty-one, the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand eighteen, the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (12-21)Reverse 7 ® DATE(MM/DD/1Y/YY) A�o CERTIFICATE OF LIABILITY INSURANCE 5/13/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTANAME:CT Mark Grasela Arthur J. Gallagher Risk Management Services, Inc. PHONE FAX 4000 Midlantic Drive Suite 200 alC No Ext:856-482-9900 A/c No:856-482-1888 Mount Laurel NJ 08054 nDDRess: CherryHill.BSD.CertM@AJG.com INSURER(S)AFFORDING COVERAGE NAIC# INSURERA:Gotham Insurance Company 25569 INSURED TRINHEA-03 INSURERS:National Union Fire Insurance Company of Pittsburg19445 Trinity Solar Inc. 2180 Fifth Avenue, Unit 1A INsuRERc:Liberty International Underwriters Ronkonkoma, NY 11779 INSURERD: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:1248340122 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY NUMBER MMIDPOLDY� MM/DDIYYYY EXP LIMITS LTR A X COMMERCIAL GENERAL LIABILITY GL202100013378 6/1/2021 6/1/2023 EACH OCCURRENCE $2,000,000 DAMAGE TO—7CLAIMS-MADE a OCCUR PREM SES Ea occurrence) ccurr RENTED ncs $100,000 MED EXP(Any one person) $5,000 PERSONAL 8 ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERALAGGREGATE $2,000,000 POLICY[X] PRa LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ B AUTOMOBILE LIABILITY CA 2960145 6/1/2022 6/1/2023 COMBINED SINGLE LIMIT S2,000,000 Ea accident X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident L $ A UMBRELLALIAB X OCCUR EX202100001871 6/1/2021 6/1/2023 EACHOCCURRENCE $5,000,000 C ELD30006989101 6/1/2022 6/1/2023 C X EXCESS LIAB CLAIMS-MADE 1000231834-06 6/1/2022 6/1/2023 AGGREGATE $5,000,000 DED RETENTION$ Limit x of$5,000,000 $19,000,000 B WORKERS COMPENSATION WC 13588108 6/1/2022 6/1/2023 X AND EMPLOYERS'LIABILITY STATUTE ER ANYPROPRIETOR/PARTNER/EXECUTIVE YN/A E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 B Automobile CA 2960145 6/1/2022 6/1/2023 All Other Units $250/500 Comp/Collusion Ded. Truck-Tractors and Semi-Trailers $250/500 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Route 25 AUTHORIZED REPRESENTATIVE Southold NY 11971 ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Trinity Solar Inc. 631-319-7233 2180 Fifth Avenue,Unit 1A Ronkonkoma,NY 11779 1c.NYS Unemployment Insurance Employer Registration Number of Insured 49-230977 Work Location of Insured (Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 22-3292324 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) National Union Fire Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"1 a" 54375 Route 25 WC 013588108 Southold,NY 11971 3c.Policy effective period 6/1/2022 to 6/1/2023 3d.The Proprietor,Partners or Executive Officers are ❑ Included.(Only check box if all partnerstofficers included) E] all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box 1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Michael Price (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 2Pk�/D4uz 6/1/2022 (Signature) (Date) Title: C.E.O.North America Telephone Number of authorized representative or licensed agent of insurance carrier: Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE -` Name WILLIAM F CONDIT Business Name This certifies that the Trinity Solar Inc Dearer is duly licensed Dy the County of suffolk License Number:H-52821 Rosalie Drago Issued: 01/29/2014 Commissioner Expires: 01/01/2024 Suffolk County Dept.of Labor,Licensing$Consumer Affairs MASTER ELECTRICAL LICENSE Name iI RICHARD GUANERI This C9tifeg Thal the Business Name bearer is duly licensed Trinity Solar Inc. by the County of suffolk License Number:ME-57843 Rosalie Drago Issued: 12/15/2016 Commissioner Expires: 12/01/2022 Oflidtfionzed alferafi8n or addition to this survey Is a violation al Copies 7209 of thenc Nmrs Ynet bearinte g the Lando surveyor's inked SUFFOLK COUNTY HEALTH DEPARTUM7 Gopias of iFas survey p 'seal cr embo—od::-I:'- !I nct bo jo�:idc•ed:o be a va�d copy E 0� �I 1g77 Guacnt�es or csruac4o. ,i�r:�t• he=1 shall run only to 'F H. D. REP. #_ -S � �\ Pers—for whom the n ..t ropareJ,tort on his 6ahatf to the �J - I,IIe company,JGYErfT:I.IaI cy_nry card landing institution 11$� sewage dillposal j.,1 jater SUDply hereon,and to the cssigneas of the lending institution Guara,"tiities for thiA lora!Il:n ;7[iYB been or certifications are not transferable to additional instdunonfnSpeQted b, tb'_a dt�B4= L�1 a ppb / l wbsequent owner. to be satiafuatorps j r14.1 ¢bief of General Engineerj#A b` p0 Servicen �? v<� to i Ay r° to RAE 7- 0 0 Oe R Ilk \a N P z AftY pSEM,Ept \`� v E win YEIApORa,tN K \N N 78,r ,tK M �J es \R1 srµ o "~ \ n \ cn sem' u 1 TGST QORlNG 3 os n a, 12 5.0 041N -A • c....r -1 s� Ao 29 0 s T f io z Va' SO.ve w/is.v� All distances to wells and cesspools are by location from house owners and field observations,since most wells and cess- o arse pools are not visible these dimensfarte cannot be certified. SURVEY FOR REFERENCE MARVIN E. & LILLIAN QUALLS AT LAUREL tPf"�OF NEW YOq� TOWN OF SOurkOLD GUARANTEED ro r 5 �oO�RT A. lk SUFFOLK COUNTY, N.Y. SCALE : la= 50' f APRIL 27, 1977 r AUG.15,r977 xa. � RIVERNEA Y. ' SOLAR Southold Town, NY July 3, 2022 Town Hall Annex Building54375 Route 25 P.O. Box 1179 Southold, NY 11971 RE: STEPHEN SCHOTT Trinity Solar No. 2570 MAIN RD 2022-05-704679 LAUREL, NY 11948 To the Building Official: The following information constitutes a summary of the relevant design criteria and recommendations for the support of a new photovoltaic[PV] system on the existing roof framing components at the above-referenced location. Criteria is as follows: 1. Existing roof framing: Conventional roof framing at Roof R2 & R3 is 2x8 at 24 o.c.; maximum existing rafter span= 14' 5"; (horizontal projection) 2. Roof Loading: • 3.Opsf dead load (pounds per square foot- PV panels, mounting rails & hardware) • 6.3psf-existing roof loads (2.3psf-2x8 framing, 1.5psf roof sheathing, 2.5psf shingles) • Ground Snow Load -20psf- per AHJ (Authority Having Jurisdiction) • Wind criteria- Exposure Category B, 128mph wind 3. Existing Roof modification - none required; existing roof framing is acceptable for PV installation. The installation, described above, is in general conformance with the manufacturers'specifications and complies with all applicable laws, codes, and ordinances as specified by applicable codes, including the 2020 Residential Code of New York State. The spacing of the mounting brackets cannot exceed a maximum of 48"o.c. between mounting brackets and will be fastened using 5/16"diameter corrosive-resistant steel lag bolts. In order to evenly distribute the load across the roof rafters, there shall be a minimum of 2 mounting brackets per rafter(4" long lag bolts required) and a minimum 2'/2' penetration (embedment)of all bracket lag bolts beyond the roofing materials; this is adequate to resist all stated live loads above— including wind shear. Per NDS Section 12.1.4, pilot holes not to exceed one-half the diameter of the shank need to be bored into the primary framing members for the full length of the threaded portion of the screw to avoid splitting of the framing member. Stainless steel lag bolts are required. Regards, Thor Bojcun, PE OF NFA y Structural Engineer-Trinity Solar C7 Ips W ,�,o 095675 --- RCFfSSoA NY License No.095675 Trinity Solar 12180 5th Avenue,Unit 1 Ronkonkoma,NY (631)319-7233 M Doi EcoFasten, For Installers. By Installers. rh-4t+,bGF 6 COMPLETE RAIL-BASED RACKING SYSTEM ClickFit is one of the fastest installing rail-based systems i in the industry. Thanks to its Click-In rail assembly, the Composition Shingle, Tile,Metal. rails can be connected to any of EcoFasten's composition r„ shingle, tile, and metal roof mounts in seconds without - the need for fasteners or tools. The ClickFit system is made of robust materials such as aluminum and coated :::: Rail-Based steel,to ensure corrosion-resistance and longevity. ClickFit conforms to UL 2703 and has been tested in - - - - extreme weather conditions including wind,fire,and snow. FEATURES & BENEFITS Structural-Attach Direct-Attach • Tool-less,fastener-free rail attachment • Fully integrated bonding • Click-On Mid&End Clamps • Compatible with a variety of EcoFasten roof attachments FAST INSTALLING SYSTEM FEATURING }25 YEAR WARRANTY 0 0. CLICK-IN RAIL ASSEMBLY �` � Ism= . INTERNAL SPLICE Tool-free bonded internal Splice installs in seconds. MLPE MOUNT , �.. Attach Module Level Power MID CLAMP Electronics to the top of the railOPO'01 Click-on mid clamp features integrated ✓ bonding pins and fits modules 30-50 mm in width. ENO CLAMP Click-on end clamp fits modules END C A P 30-50 m m in width. The slide-on end caps allow the end clamps to be accurately positioned on the rail in seconds, while providing an aesthetically- pleasing, finished install. ' L- FOOT The ClickFit rail simply clicks ' into our proprietary composition s shingle & the L-foot without the t ? need to use fasteners or tools. u, t COMPOSITION SHINGLE Combine the versatile ClickFit L-Foot with the watertight GF-1 flashing for a fast , um£. installation on composition shingle roofs. GF-1 FLASHING&L-FOOT TILE ROOFS Si.. Use the adjustable ClickFit Tile Hook for attaching the ClickFit system to tile roofs. Works with - Flat, S, and W the profiles. A CLICKFIT TILE HOOK STNOIG SEAM METAL ROOFS Combine the ClickFit L-Foot with SimpleBlock°-U for a - fast installation on standing seam metal roofs. SIMPLEBLOCK-U y PRODUCT j' PART PART BOX PALLET IMAGE NUMBER I DESCRIPTION QUANTITY ;i QUANTITY ASSEMBLED WITH(1)GF GROMMET AND INCLUDES(1)5/16-EPOM BONDED WASHER - GF1M-GAL-BLK-810 GF1 8X10"BLK GLV 50 3200 W/2"HL PLCMT - GF1-GAL-BLK-812 GF1 8X12"GALVALUME BLK 50 2600 FLASHING ALL HARDWARE iO 1500004 CF L-FOOT ASSY 100 5000 (NO HARDWARE NEEDED) 1500005 CF TILE HOOK US 20 480 1510045 CF TILE HOOK SUB-FLASHING 20 2160 TILE HOOK FLSH-F ST TILE HOOK FLASH12 576 FLAT SIERRA TAN TILE HOOK FLSH-W ST TILE HOOK FLASH 12 576 W SIERRA TAN TILE HOOK FLSH-S ST TILE HOOK FLASH 12 576 S SIERRA TAN SIMPLEBLOCK-U-AL 2"SIMPLEBLOCK SSR-AL 25 4400 ALL HARDWARE i OO 1500004 CF L-FOOT ASSY 50 5000 (NO HARDWARE NEEDED) 1500033 CF RAIL 2130MM N/A 108 (-7 FT) 1500034 CF RAIL 3166MM N/A 108 (-10.4 FT) 1500035 CF RAIL 4202MM N/A 108 (-13,8 FT) T 1008051 CF RAIL SPLICE 100 3200 1510070 CF WIRE MGMT CLIP 1000 T130 1 1500028 MODULE JUMPER,B IN 25 25000 (20404MM) e7_ � .� 1510057 CF MLPE MOUNT 400 17600 . A PRODUCT ( -PART PART BOX PALLET { IMAGE !i NUMBER DESCRIPTION �' QUANTITYQUANTITY i _f _1- it 1510041 OF ENDCAP,ELK LABELED 100 4800 1510015 OF HD 3OMM,BLK MP 20 5600 1510016 OF HD 32MMDBLKMP 50 5600 1510017 CF HO ENOCLAMP 50 5600 35MM,BLK 1510016 OF HDENDBLKMP 50 5600 F 1510019 OF HO 40MM,BLK MP 50 5600 1510020 OF HO 45MMDBLKMP 50 5600 1510011 OF HD MIOCLAMP 50 5600 Y l9 30-4OMM,BLK 1510012 CF HD MIOCLAMP 50 5600 40-5OMM,BLK ROCK-IT V3 SKIRT A65 ROCK-IT SKIRT V3 8 256 35MM&40MM 65" ROCK-IT V3 SKIRT A79 ROCK-IT SKIRT 8 256 79 35MM&40MM 79" ROCK-IT V3 SKIRT A80 ROCK-IT SKIRT V3 8 256 35MM&40MM 80" ROCK-IT V3 SKIRT B65 ROCK-IT SKIRT V3 8 256 32MM&38MM 65" ROCK-IT V3 SKIRT B79 ROCK-IT SKIRT 79 8 256 32MM&38MM 79" ROCK-IT V3 SKIRT BBO ROCK-IT SKIRT V3 8 256 32MM&38MM 80 1500003 OF UNIVERSAL SKIRT 50 5750 CLAMP BLK POLY KIT LAO SCREW 4 POLY KIT LAG 50 480 SCREW 4"(5O) SCRW OP 15-13X03 ROOFING SCRW 1000 60000 #15 X 3"DRILL PT INCLUDES(1)2"LAG BOLT AND 1510001 CONOUITMOUNT-BRKT 50 10350 INCLUDES(1)SS 8-18 X 3/4"TEK SCREW '- CONOUITMOUNT-TILE CONDUIT MOUNT-TILE SYSTEM 60 4320 S : � F ' r fl�ro> r' 1& � ,u. -.`� a j � � ':� rad¢ n i�i�• �s,r, ',,,r��+,�3' x }�s �••��al`�,���/may'.;,:s e a- �`.- l,,s ;, .�,�"t i'.€-_ �•„.- 1"J.WS_” -YJ '*^'i1n �`'t�..-. _ '�t��..Jc-s,L �T.r".' -Sf`.`'�';y- '•�',,.'.b*`7 µ -- _._. _ III''' _ ,�''.`-•-••;•^�`'..0-�-'x :. �'� ..���_N a> �x - `�, j G.�=�=^a;�.^ch•'- '\;f'-^- ��—'a•1. �•=;�:r::•>�_ •,�.-,�"'�—_''�-'��'._ ���?. ..a.:a"y�.'�,�^rn=•,.-:ase � .�:�.�-:r. -�::�':._ • - y e `tet-"`-�• ,� 7�. _ ��+ ,.`:sem y - ����L�'• q�� �5`s.�..r,x�``a�-''". _�;::.''�;:`'�",, t s ri, r a •"r � `-?�.,.r '``•fir '8`�u3.'y xt t may. .�� " jxN;vH `w tJ nstyF .`�,,L .;-�,K,�,t.�+•g-..s''W :; f.'+t ,`ice-kr -'j2r -a_' - �ry��'` �'`„}„ .� '�• .w� r"rc '�'��t�'k�xyxP iky ;,c w �.��� •.a, v �,e.• �" v.<�3-. ',_`i�F• " yz„5' $t „'k, r^ Cf dsl:s 1 aMyry 4 r� lc'. "�p: �; '��'�"+' ,��. � �� *+, �] � '�4 5 �'° 'i~- gi+��ma to �� �•1 ECOFASTEN SOLAR EcoFasten has an established a reputation for being one of the industry's leading innovators by providing expert solutions for mounting solar PV on any type of roof. Our broad portfolio of solutions stem from the needs of, and direct inputs by solar PV installers. We take pride in providing the right solution for every application. We educate our customers, so they purchase the best, most cost-effective solutions to fit their needs, and we complement that with on- site installation training to ensure 100% satisfaction. We are honest with ourselves, our customers, and our employees, fostering a culture of idea-sharing, innovation, and creativity. < r 4141 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009 EcoFasten ; An ESDEC Company 1 - 877 - 859 - 3947 INF0@EC0FASTENS0LAR.00M a. Single Phase Inverter Z • TechnologyC with HD-Wave m for North America X SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE1000OH-US / SE1140OH-US '..'..' 112 EAR Ln A � I i I i ® ® 1 j solar,�� .,.,7y wave Q 0 solar=-- —.141D..— 11 Q 9 Q _1 0 a, '0 4; Optimized installation with HD-Wave technology / Specifically designed to work with / UL1741 SA certified,for CPUC Rule 21 grid compliance power optimizers / Record-breaking efficiency / Extremely small / Quick and easy inverter commissioning directly / Built-in module-level monitoring from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article / Optional: Revenue grade data,ANSI C12.20 690.11 and 690.12 Class 0.5 (0.5%accuracy) solaredge.com solar=v " i n i / Single Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom.-Max ✓ ✓ ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.5") Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V Power Factor 1,adjustable-0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208W-) - 9 13.5 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption I <2.5 W For other regional settings please contact SolarEdge support �a A higher current source may be used;the inverter will limit its input current to the values stated J- / Single „ ® Sin le Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional!31 Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi Access Point for local connection Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to TILL M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG 1”Maximum/14-6 AWG 1"Maximum/14-4 AWG Range DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG T'Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ (HxWxD) mm Weight with Safety Switch 22110 251/11.4 26.2/11.9 38.8/17.6 Ib/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60t' Protection Rating NEMA 4X(Inverter with Safety Switch) t31 Revenue grade inverter P/N:SExxxxH-US000BNC4 (41 Full power up to at least 50'C/122'F;for power de-rating information refer to.https://www.solaredge.com/sites/default/fiies/se-temperature-derating-note-na.pdf O SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BV SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc All Ro H S other trademarks mentioned herein are trademarks of their respective owners.Date:5/2019N01/ENG NAM.Subject to change without notice. powered by NMM=ffV07fl j YR 51 1t TOP EUROPE Warranty 021Q CELLS ,.duct&p,a,( a Yield Security BREAKING THE 20%EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE �- Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect and Traceable Quality Tra.QM. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). A RELIABLE INVESTMENT VAY Inclusive 25-year product warranty and 25-year r r linear performance warrantyz. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: (10 Rooftop arrays on residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION Format 74.0 in x 41.1 in x 1.26 in(including frame) (1879 mm x 1045 mm x 32 mm) Ta.o•(a emm) 42.8'(10013.,r) 15.6'(3955mm) Weight 48.5lbs(22.Okg) Front Cover 0.13in(3.2 mm)thermally pre.stressed glass with q9 z(2wmm) anti-reflection technology ^ q•Glama°p porrt°a 016'(4.5 mml Frame Back Cover Composite film 39.Y(996 mm1 Frame Black anodized aluminum a11•pogsmm) Cell 6 x 22 monocrystalline Q.ANTUM solar half cells ® Junction Box 2.09-3.98 in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes L°W zg9,Z1250mm) Cable 4mm2Solar cable,(+)>-49.2in(1250mm),(-)>-49.2in(1250mm) q•NamtlrS slot.loaraL A) - Connector Staubli MC4;IP68 �f-L26•(3]mm) DETNLA 063•(16') -� 0.9fi'(Ig5 mm)I-OI033'(66mm1 ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 , MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-0 W) Power at MPP' PNpp [W] 385 390 395 400 405 Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 E E Open Circuit Voltage' Vcc [V] 45.19 45.23 45.27 45.30 45.34 Current at MPP INpp [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VNpp [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' V [%] 219.6 119.9 >_20.1 220.4 2t 20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PNpp [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current [A] 8.90 8.92 8.95 8.97 9.00 > Open Circuit Voltage VGc [V] 42.62 42.65 42.69 42.72 42.76 E Current at MPP INpp [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VNpP [V] 34.59 34.81 35.03 35.25 35.46 =Measurement tolerances PNpp±3%;Isc;Voc±5%at STC:1000 W/m3,25±2°C,AM 1.5 according to IEC 60904-3.280OW/m2,NMOT,spectrum AM 1.5 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98%of nominal power during s>n a 9° first U year.Thereafter max.0.5%W 2 �a „ ----- _--_-__.____.- ------- degradation per year.Atleast 93.5% u loo---------- ----- of -------- -----of nominal power up to 10 years.At Z F z least 86%of nominal power up to W ' a I wo - -------- -- 25 years. < 96 --------------I------+------� z �z I o ° D ° All data within measurement toleranc- es.Full warranties in accordance with 60 a the warranty terms of the O CELLS 900 qoo coo 1101) 1600 0 o sales organisation of your respective IRRADIANCE[W/m'] o ° country. YEARS _ o m YEARS Typical module performance under low irradiance conditions in o comparison to STC conditions(25°C,1000 W/mz) m TEMPERATURE COEFFICIENTS o Temperature Coefficient of I c e [%/K] +0.04 Temperature Coefficient of V oc Q [%/K] -0.27 � Temperature Coefficient of PNpp y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) O PROPERTIES FOR SYSTEM DESIGN ° a Maximum System Voltage Vs,.s [V] 1000(IEC)/1000(UL) PV module classification Class II o N Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI UL 61730 TYPE 2 w Max.Design Load,Push/Pull' [Ibs/ft2] 75(3600IDS)/55(2660Pa) Permitted Module Temperature -40°F up to+185*F p Max.Test Load,Push/Pull' [Ibs/ft2] 113(5400 Pa)/84(4000 Pa) on Continuous Duty (-40oCupto+85oC) o 'See Installation Manual (QUALIFICATIONS AND CERTIFICATES /� PAC/K�AGINGG���INFORMATION UL 61730,CE-compliant, f�/N <I\/I Ib 53'n NOR- Quality Quality Controlled PV-T0V Rheinland, I>c1AV� `Nd�� --1 AO HC -1 0-0 ° IEC 61215:2016,IEC 61730:2016, ♦ �, U.S Patent No.9.893,215(sotercells), sA® (. IlTU.-l- Horizontal 76.4in 43.3 in 48.Oin 1656lbs 24 24 32 QCPV Certification ongoing. C US ` ♦ packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules _ ui51730 Tia lDiriii:oni o Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha 0 CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiryQus.q-cells.com I WEB www.q-cells.us NOTES: 1.)COMPLIES WITH NEC 2017 2.)REFER TO SHEET PV-3 FOR SITE SPECIFIC VALUES REQUIRED BY NEC 690 - 3.)STICKERS,LABELS,AND PLACKARDS SHALL BE OF SUFFICIENT OURRABILITY TO WITHSTAND THE ENVIROMENT INVOLVED • To be located on all DC junction boxesWIfH RAPHUTWYMED ty and every 30'on DC cendult 6 SOLAR NEC 590.31(G) "^^ NEC 690.56(C)(3)(A) DC Junction Box y • • • 69056(CI(3) NEC 690.4(8) Service Disconnect •690.56(C)(3) NEC 690.13(8) NEC 690.53 Soladeck • • • `'� SOLAR PV SYSTEM EOUIPPFD ® I s- • • • WITH RAPID SHUT00WN NEC 690.4(8) . -J i NEC 690.13(8) f NEC 690.56(C)(1)(A) `E If System Is Backfed Breaker ' NEC 69054 NEC 690.53 NECEC 7® ® -` DC Disconnect NEC 690.54 al Utility Meter *� _ Socket Now If`® �NEC690.13(B) l NEC 690.54 •NEC 690.13(8) { DC Conduit Main Service Panel Solar Meter Socket Photovoltaic Load Center Inverter(s) Enphase Envoy Box AC Disconnect (To Combine Inverters) E INSTALLATION OF NEW MAIN ROAD• a PV SOLAR SYSTEMROOF MOUNTED eov 2570 MAIN ROAD ti LAU REL NY 11948 rn 5675 SS101A Issued/Revisions S Rl NAME 7/7/3013 P1 ISSUED TO TOWNSHIP FOR PERMIT 6/13/1022 VICINITY MAP SITE NO. DESCRIPTION DATE SCALE: NITS Project Title: STEPHEN SCHOTT ,D/'S u S4- /Y�'C®-/ t O T C..CQ ,0 4 TRINITY ACCT#:2022-05-704679 Project Address: /)f 4-sl*de a.���,ed f � .d�'�y Cc'e�'�'b 2570 MAIN ROAD �/� I LAUREL,NY 11948 40.969282,-72.560029 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX Drawing Title: 1. THE INSTALLATION CONTRACTOR IS 8. THE DC VOLTAGE FROM THE PANELS IS 14. B) CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC COMPANY SPECIFICATIONS, kCMIL THOUSAND CIRCULAR MILS EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS kVA KILO-VOLTAMPERE PV-2 ROOF PLAN W/ MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILO-WATT CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND L LINE MCB MAIN CIRCUIT BREAKER 2. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.ONCE APPROVED,THE AP APPENDIX Drawing Information RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE INSTALLATION CONTRACTOR IS MDP MAIN DISTRIBUTION PANEL EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE RESPONSIBLE FOR INSTALLING ALL MLO MAIN LUG ONLY DRAWING DATE: 6/23/2022 COMPLY WITH ALL CODES OF DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. SYSTEM COMPONENTS AS DESCRIBED IN MTD MOUNTED DRAWN By: 1C IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR THE DRAWING PACKAGE. MTG MOUNTING 3. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE 16 ALL INFORMATION SHOWN MUST BE N NEUTRAL REVISED BY: DMR N E W YORK STATE & TOWN CODE33 RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CERTIFIED PRIOR TO USE FOR NEC NATIONAL ELECTRICAL CODE AS REQUIRED AND CONDITIONS UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE CONSTRUCTION ACTIVITIES. NIC NOT IN CONTRACT COMPONENTANDINVERTERMANUALS ARTICLE 6908705. NO# NUMBER AppR �®AS NOTED System Information: NTS NOT TO SCALE ^ DC SYSTEM SIZE: 12.4kW PRIOR TO INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS OCP OVER CURRENT PROTECTION I CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THE ABBREVIATIONS P POLE AC SYSTEM SIZE: 10kW ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL MODULE COUNT: 31 POSITION AND FUSES REMOVED PRIOR TO ATTEND APRE-INSTALLTION MEETING AMP AMPERE PB PULL BOX DATE: .P.# S'v I,''- J TOWN PLANNIN BOAR THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AC ALTERNATING CURRENT PH H PHASE MODULES USED: HANWHA 400 SYSTEM COMPONENTS. PROCEDURES.SCHEDULES,SAFETY AND AL ALUMINUM PVC POLY-VINYL CHLORIDE CONDUIT MODULE SPEC#: Q.PEAK DUO BLK ML-G10.a+400 FEE: r BY: 4.ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. AF AMP.FRAME PWR POWER y ®� �l - I I EES UTILITY COMPANY: PSEG-LI MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFF ABOVE FINISHED FLOOR OTY QUANTITY NOTIFY BUILDING DEPARTMENT AT UTILITYACCT#: 9691115504 CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL AFG ABOVE FINISHED GRADE RGS RIGID GALVANIZED STEEL ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL AWG AMERICAN WIRE GAUGE SN SOLID NEUTRAL 765-1802 8 AM T'.� "M FOR THE •L' UTILITY METER#: 98357352 SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC WIRING C CONDUIT (GENERIC TERM OF JSWBD SWITCHBOARD DEAL TYPE: SUNNOVA COURSE ON SITE. CONDUCTIVITY CHECKS. RACEWAY,PROVIDE AS TYP TYPICAL FOLLOWING INSPCCi;CINS: U.O.I. UNLESS OTHERWISE INDICATED 5. FOR SAFETY,ITONCRE RECOMMENDED ALWAYS THATHAVE 12. FOR THE LATION OPER OF MAINTENANCE REFER SPECIFIED) WP WEATHERPROOF 1. FOUNDATIOIti - TWO REQUIRED THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CB COMBINER BOX XFMR TRANSFORMER CONCRETE Rev.No. Sheet MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CKT CIRCUIT XF TRAMOUNFORMET 72 HESTOBOTTOM FOR POURED ONCREIE OCCUPANCY OR TOGETHER AND THAT EACH OF THE OPERATION MANUAL. CT CURRENT TRANSFORMER OF ABOVE FINISHED FLOOR OR "' INSTALLATION CREW MEMBERS BE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC CU COPPER GRADE 2. ROUGH - FRAIV4;1l'JG & PLUMBING R 1 PV IN FIRST AID AND CPR. TAND OFINAEPHONEALOFIESARESUBJECT DI DIRECTCURRENT 3. INSULATION _ USE IS UNLAWFUL 6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF THE DISC DISCONNECT SWITCH BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND DWG DRAWING 4. FINAL - CG"i.- _ ^'i: IN MUST CONVENTIONSTHE ANY LOCAL OWNERS. EC ELECTRICAL SYSTEM INSTALLER ;l WITHOUT CERTIFICA ELECTRICAL CODE.ANY LOCAL CODE 14. ALL MATERIALS,WORKMANSHIP AND EMT ELECTRICAL METALLIC TUBING BE COMPLF'i= F�. �; , WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION FOR THE SITE FS FUSIBLE SWITCH GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL FU FUSE .ALL CONSTRUCTI':P•: SHALL MEET THE 7. ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH: GND GROUND REQUIREMENTS OF I!-!E(;ODESOFNEW OF OCCUPANCY f INSTALLED WITH THIS SYSTEM ARE TO BE A) CURRENT PREVAILING MUNICIPAL GFI GROUND FAULT INTERRUPTER "UL"LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, HZ FREQUENCY (CYCLES PER YORK STATE. NOT RESPONSIBLE FOR 3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS SECOND) GENERAL NOTES DESIGN OR CONSTRUCTION ERRORS. tv ELECTRICAL S01 A R IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABILITY OF EQUIPMENT. �® g� /v np ® ^ C 2211 Allenwood Road 877-786-7283 INSPECTION REQUIRED Wall,New Jersey 07719 www.Trinity-Solar.com NOTES:•REFER TO MODULE SPECS FOR MODULE DIMENSIONS *DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE ECOFASTEN CLAMP NEW PV SOLAR MODULE,TYPICAL (REFER TO SPEC SHEET FOR DETAILS) (REFER TO EQUIPMENT SCHEDULE FOR SPECS AND QUANTITIES) SOLAR MODULE SOLAR MODULE ♦ __ NEW MOUNTING FOOT/ATTACHMENT POINTS,TYPICAL (REFER TO ECOFASTEN"L"FOOT— OOT ECOFASTEN RAIL t.5 90 ENGINEERING LETTER FOR SPACING _ X (REFER TO SPEC SHEET FOR DETAILS) (REFER TO SPEC SHEET FOR DETAILS) _ \ AND DETAILS) < 9 NEW ECOFASTEN RAIL,TYPICAL N TO BE MOUNTED PERPINDICULARTO EXISTING ASPHALT SHINGLES ECOFASTEN FLASHING STRUCTURE(REFER TO ECOFASTENr^ �'` ` �O DETAILS)SPECIFICATION/DATA SHEET FOR (REFER TO ENGINEERS LETTER FOR SPECS) (REFER TO SPEC SHEET FOR DETAILS) MT "J / , d c NEW END CLIP,TYPICAL S.S.LAG BOLT APOC SEALANT 522\\ 1.n 0 , _♦ __ _♦ (REFER TO ECOFASTEN SPECIFICATION (REFER TO ENGINEERS LETTER FOR SPECS) SOLAR MODULES SHALL NOT /DATA SHEET FOR DETAILS) EXISTING RAFTER EXCEED PEAK HEIGHT. n t r1LIJ (REFER TO ENGINEERS LETTER FOR SPECS) LU NEW MID CLIP,TYPICAL (REFER TO ECOFASTEN SPECIFICATION !DATA SHEET FOR DETAILS) d .0-95675 []ATTACHMENT&CLIP DETAIL PV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF []HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF AA SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE R�FESS�QNP•\!. ARRAY SCHEDULE G Issued/Revisions RS NAME 7/7/2022 P1 ISSUED TO TOWNSHIP FOR PERMIT 6123/2022 NO. DESCRIPTION DATE DC Project Title: p Ac L (CONDUIT TO BE TRENCHED APPROX.60 FEET) M R4 R3 STEPHEN SCHOTT E ` - - - - j TRINITY ACCT#:2022-OS-704679 t5/5 J-111-11i I'll Project Address: LU 2570 MAIN ROAD R6LD LAUREL,NY 11948 - 40.969282,-72.560029 t- Y Z � Li m Drawing Title: , '—...I IN LL c/) R1 EE tttt :rtp: cEtpE __ pLLt PROPOSED PV SOLAR SYSTEM –11-...... 1 j 11 -- --- SHE Drawing Information IE R7 DRAWING DATE: 6/ 23/ 2022 --- DRAWN BY: JC REVISED BY: DMR • = =tteeee� _ ` �a—=`_ S stem Information: _�Lt E t�t DC SYSTEM SIZE: 12.4kW AC SYSTEM SIZE: 10kWLR MODULE COUNT: 31 MODULES USED: HANWHA 400 MODULE SPEC#: Q.PEAK DUO BLK ML-G10.a+400 UTILITY COMPANY: PSEG-LI ROOF 1 UTILITY ACR#: 9691115504 MODULES:0 NOTES: UTILITY METER#: 98357352 PITCH:40° ORIENTATION:61° 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE DEAL TYPE: 5UNNOVA ROOF 2 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. MODULES:19 2.)ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. PITORIENTATION:241 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Rev.NO. Sheet 4.) AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S) NEC 690.13(E) ROOF 3 5.) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. MODULES:12 6.) ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. PITCH: R 1 P V - 2 ORIENTAA TION:151 ROOF4 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE MODULES:0 QTY SPEC# PITCH:27* ORIENTATION:331° R1 INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE SP INDICATES NEW PV ONLY SUBPANEL ARRAY SCHEDULE FOR MORE INFORMATION UD INSTALLED OUTSIDE (UTILITY ACCESSIBLE) TO BE INSTALLED 31 HANWHA 400(Q.PEAK DUO BLK ML-G10.a+400) ROOFS MODULES:0 INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SE10000H-USOSHBNC4 PITCH:34° • • ORIENTATION:331° INDICATES EXISTING METER LOCATION INDICATE PANELS THAT USE MICRO INVERTERS. pC INDICATES NEW DC DISCONNECT ROOF MODULES:0 REFER TO EQUIPMENT SCHEDULE FOR SPECS. OTHER OBSTRUCTIONSr n it ' T PITCH:34° INDICATES EXISTING ELECTRICAL PANELINDICATES NEW PRODUCTION METER TO BE Tr ORIENTATION:61° EP LOCATION: IN BASEMENT INSTALLED OUTSIDE. SD INDICATES EXISTING SERVICE DISCONNECT SOLAR OLA R MODULES:0 INDICATES NEW INVERTER TO BE PITCH:34° INDICATES NEW FUSED PV DISCONNECT TO BE 2211 Allenwood Road 877-786-7283 ORIENTATION:241° INSTALLED OUTSIDE(UTILITY ACCESSIBLE) INSTALLED OUTSIDE. TS INDICATES EXISTING TRANSFER SWITCH AC REFER TO EQUIPMENT SCHEDULE FOR SPECS Wall,New Jersey 07719 www.Trinity-Solar.com : Engineer/License Holder: ARRAY CIRCUIT WIRING NOTES SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS 1. LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY 31-40OW MODULES W/1 SOLAR EDGE 5440 PER MODULE FOR DETERMINING ONSITE CONDITIONS AND 15 ADC MAX PER STRING EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2017 (TOTAL) _ 1 STRING OF 9 MODULES IN SERIES-400 Vmax 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON 1 STRING OF 10 MODULES IN SERIES-400 Vmax ASHRAE MINIMUM MEAN EXTREME DRY BULB 1 STRING OF 12 MODULES IN SERIES-400 Vmax TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO *3 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 C-) 8"x8" INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT --- ------ --------------------------------------- ------ .Z a (. TEMP=-16'C (HOUSE) C JUNCTION D 1 .2•A .A. -Z '. 1 STRING OF 9 MODULES IN SERIES-400 Vmax r BOX 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED 1 STRING OF 10 MODULES IN SERIES-400 Vmax ON ASHRAE HIGHEST MONTH 2%DRY BULB *2 STRING TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 e m m m m m= I 171 TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO I , -7- INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= (GARAGE) ------ 8"x8" __________ ________ I I 6"x6" ---� `tf C.7' 330C 1 STRING OF 12 MODULES IN SERIES-400V max C JUNCTION JUNCTION I ���� �9g6715 *1 STRING TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 r BOX I BOX 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN IR�F�'SS 10N�L� TEMPERATURES DO NOT EXCEED 470C IN THE UNITED I - STATES(PALM SPRINGS,CA IS 44.1°C). FOR LESS THAN 9 DC DISCONNECT CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED I Issued/Revisions SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING I THE OUTDOOR DESIGN TEMPERATURE OF 470C OR LESS I (ALL OF UNITED STATES) I 5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS I ai NAME 7/7/2022 SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT I CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I P2 ISSUED TO TOWNSHIP FOR PERMIT 6/23/2022 NEC 690.12(A)THROUGH(D) NO. DESCRIPTION DATE 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC [ Project Title: SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4) STEPHEN SCHOTT 7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: I TRINITY ACCT#:2022-05-704679 POSITIVE CONDUCTORS=RED NEGATIVE CONDUCTORS=BLACK EXISTING 240V 10 INTERNAL REVENUE GRADE MONITORING NOTE: I NEC 230.5(C)(2) 10 120/240V � 200A MAIN BREAKER Project Address: UTILITY METER 200A BUSBAR CONTAINED WITHIN SOLAR EDGE INVERTER 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV SOLAR EDGE PN.RWND-3D-240-MB WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BEL 2570 MAIN ROAD PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT LAUREL,NY 11948 SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24"SHALL 40.969282,-72.560029 CONTAIN<_20 CURRENT CARYING CONDUCTORS AND s£ WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN 5 9 CURRENT CARRYING CONDUCTORS. I Drawing Title: 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS LOCKABLE 60A DISCONNECT INVERTER#1 OTHERWISE NOTED FUSED W/60A FUSES `^ 10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON 240V 1 > + `'' PROPOSED PV SOLAR SYSTEM ROOFTOP AND SHALL BE LIMITED TO 12"IF USED 10 0 m"e m e a OUTDOORSI `� --- 0 I I 11.)OVERCURRENT PROTECTION FOR CONDUCTORS I 0 I Drawing Information CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE e m �°^"� \J\ n 0 __ m a m J DRAWING DATE: 6/23/2022 LOCATED WITHIN 10'OF THE POINT OF CONNECTION NEC m L 5 m -* C Ll�N� DRAWN BY: 1C 705.31 I- 1 0 REVISED B: DMR 12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE AIUTILITY AND THE OTHER AN INVERTER,PV BACKFEED EXISTING MAIN BREAKER LOAD CENTERSQUARED L--------J System Information: BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY INSULATED LINE TAPS INSTALLED ON PN:D222NR6 --------J NEC 705.12(B)(2)(3)(b) MAIN FEEDERS DC SYSTEM SIZE: 12.4kW 13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY NEC 705.12(A) AC SYSTEM SIZE: 10kW GENERATION CIRCUITS AND NO UNUSED POSITIONS OR MODULE COUNT: 31 LOADS MODULES USED: HANWHA 400 MODULE SPEC#: Q.PEAK DUO BLK ML-G10.a+400 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE UTILITY COMPANY: PSEG-LI A NEMA 3R RATING UTILITY ACCT#: 9691115504 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER#: 98357352 REQUIRED CONDUCTOR AMPACITY PER STRING DEAL TYPE: SUNNOVA [NEC 690.8(8)(1)1:(15.00*1.25)1=18.75A PV MODULE SPECIFICATIONS AWG#10,DERATED AMPACITY HANWHA 400(Q.PEAK DUO BLK ML-G10.a+400) AMBIENT TEMP:33°C,TEMP DERATINGFACTOR:.96 Rev.No. Sheet RACEWAY DERATING=6 CCC:0.80 Imp 10.77 (40*.96)0.80=30.72A Vmp 37.13 NOTE:CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS R1 P V 3 30.72A'_1S,75A,THEREFORE WIRE SIZE IS VALID Vac 45.3 TOTAL AC REQUIRED CONDUCTOR AMPACITY ISC 11.14 A #6THWN-2 GECTO EXISTING GROUND ROD G 1"CONDUIT W/2-#6 THWN-2,1-#6 THWN-2,148THWN-2 GROUND 42.00A*1.25=52.50A B 1"CONDUIT W/2-#6THWN-2.1-#10 THWN-2.1-#10 THWN-2 GROUND H 1"PVC W/2-#lOTHWN-2,1-#10THWN-2GROUND(TRENCHED APPROX.50') AWG#6,DERATED AMPACITY INVERTER#1-SE1000OH-USOSHBNC4 C 1"CONDUIT W/6-#10THWN-2,1410THWN-2 GROUND 1 1"CONDUIT W/2-#10 THWN-2,1410 THWN-2 GROUND A411% TC AMBIENT TEMP:30'C,TEMP DERATING:1.0 RACEWAY =75A Imp 27 Pout 10000 WAY DERATING_3 CCC:N/A 75A DC AC D 1"CONDUIT W/4-#10 THWN-2,1-#10 THWN-2 GROUND Tf fn it 0 75A'_52.50A,THEREFORE AC WIRE SIZE IS VALID Vmp 400 Imax 42 E 1"CONDUIT W/2-#6THWN-2,1-#10 THWN-2,1-#10 THWN-2 GROUND Vac 480 OCPDmin 52.5 SOLAR CALCULATION FOR PV OVERCURRENT PROTECTION ISC 45 Vnom 240 F #10 PV WIRE(FREE AIR)W/#6 BARE COPPER BOND TO ARRAY TOTAL INVERTER CURRENT:42.00A 42.00A*1.25=52.50A 2211 Allenwood Road 877-786-7283 -->60A OVERCURRENT PROTECTION IS VALID Wall,New Jersey 07719 www.Trinity-Solar.com , 3 Date: February 14th 2023 Southhold Town, NYL % Town Hall Annex Building 23 54375 Route 25 P.0 Box 1179 FEB 1 5 20 Southold, NY 11971 BUILOINGOEPT 70'am of: RE: Permit#: 48318 To Whom It May Concern, The original plans for Kristianna Schott of 2570 Main Rd, Laurel NY 11948 have been changed due to panel layout revised on array 2 and solar equipment installed on the right side of the house.The As-Built drawings that we are submitting for approval are actual layouts of the roof and equipment. If you have any questions or need further assistance,please call our office. Thank you, Trinity Solar Brittany Gaumer 631.319.7233 (ext. 1326) INSTALLATION O NEW MAIN ROAD. ,1 ROOF MOUNTED PV SOLAR SYSTEM, 2570 MAIN ROAD° AA LAUREL, NY 11948V-y 67b b�. �fiFSS IONP- F =' Issued/Revisions A2 A6-BUILT 2/8/2023 Al AS-BUILT 12/3/2022 Y RI NAME 7/7/2022 Pl ISSUED TO TOWNSHIP FOR PERMIT 6/23/2022 VICINITY MAP SITE NO. DESCRIPTION DATE SCALE: NTS Project Title: STEPHEN SCHOTT TRINITY ACCT#:2022-05-704679 Project Address: 2570 MAIN ROAD LAUREL,NY 11948 40.969282,-72.560029 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX Drawing Title: 1. THE INSTALLATION CONTRACTOR IS 8. THE DC VOLTAGE FROM THE PANELS 15 14. B)CURRENTPREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES RESPONSIBLE FOR INSTALLING ALL EQUIPMENT ALWAYS PRESENT AT THE DC DISCONNECT COMPANY SPECIFICATIONS,STANDARDS, kCMIL THOUSAND CIRCULAR MILS AND FOLLOWING ALL DIRECTIONS AND ENCLOSURE AND THE DC TERMINALS OF THE AND REQUIREMENTS kVA KILO-VOLTAMPERE PV-2 ROOF PLAN W/ MODULE LOCATIONS AS BUILT PV SOLAR SYSTEM INSTRUCTIONS CONTAINED IN THE DRAWING INVERTER DURING DAYLIGHT HOURS.ALL 15 THIS SET OF PLANS HAVE BEEN PREPARED kW KILO-WATT PACKAGE AND INFORMATION RECEIVED FROM PERSONS WORKING ON OR INVOLVED WITH FOR THE PURPOSE OF MUNICIPAL AND kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM TRINITY. THE PHOTOVOLTAIC SYSTEM ARE WARNED AGENCY REVIEW AND APPROVAL.ONCE L LINE 2. THE INSTALLATION CONTRACTOR IS THAT THE SOLAR MODULES ARE ENERGIZED APPROVED,THE INSTALLATION MCB MAIN CIRCUIT BREAKER qp APPENDIX Drawing Information RESPONSIBLE FOR INSTALLING ALL EQUIPMENT WHENEVER THEY ARE EXPOSED TO LIGHT. CONTRACTOR IS RESPONSIBLE FOR MDP MAIN DISTRIBUTION PANEL AND FOLLOWING ALL DIRECTIONS AND 9. ALL PORTIONS OF THIS SOLAR INSTALLING ALL SYSTEM COMPONENTS AS MLO MAIN LUG ONLY DRAWING DATE: 6/23/2022 INSTRUCTION CONTAINED IN THE COMPLETE PHOTOVOLTAIC SYSTEM SHALL BE MARKED DESCRIBED IN THE DRAWING PACKAGE. MTD MOUNTED DRAWN BY: JC MANUAL. CLEARLY IN ACCORDANCE WITH THE 16 ALL INFORMATION SHOWN MUST BE MTG MOUNTING REVISED BY: 1M5 3. THE INSTALLATION CONTRACTOR IS NATIONAL ELECTRICAL CODE ARTICLE 690& CERTIFIED PRIOR TO USE FOR N NEUTRAL RESPONSIBLE FOR READING AND 705. CONSTRUCTION ACTIVITIES. NEC NATIONAL ELECTRICAL CODE UNDERSTANDING ALL DRAWINGS,COMPONENT 10. PRIOR TO THE INSTALLATION OF THIS NIC NOT IN CONTRACT System Information: AND INVERTER MANUALS PRIOR TO PHOTOVOLTAIC SYSTEM,THE INSTALLATION NO# NUMBER Y INSTALLATION.THE INSTALLATION CONTRACTOR SHALL ATTEND NTS NOT TO SCALE DC SYSTEM SIZE: 12.4kW CONTRACTOR 15 ALSO REQUIRED TO HAVE ALL PRE-INSTALLTION MEETING FOR THE REVIEW OCP OVER CURRENT PROTECTION AC SYSTEM SIZE: SOkW COMPONENT SWITCHES IN THE OFF POSITION OF THE INSTALLATION PROCEDURES, ABBREVIATIONS p POLE AND FUSES REMOVED PRIOR TO THE SCHEDULES,SAFETY AND COORDINATION. AMP AMPERE PB PULL BOX MODULE COUNT: 31 INSTALLATION OF ALL FUSE BEARING SYSTEM 11. PRIOR TO THE SYSTEM START UP THE AC ALTERNATING CURRENT PH 0 PHASE MODULES USED: HANWHA 400 COMPONENTS. INSTALLATION CONTRACTOR SHALLASSIST IN AL ALUMINUM pVC POLY-VINYL CHLORIDE CONDUIT MODULE SPEC#: Q.PEAK DUO BLK ML-G10+400 POWER 4. ONCE THE PHOTOVOLTAIC MODULES ARE PERFORMING ALL INITIAL HARDWARE AF AMP.FRAME pWR UTILITY COMPANY: PSEG-LI MOUNTED,THE INSTALLATION CONTRACTOR CHECKS AND DC WIRING CONDUCTIVITY AFF ABOVE FINISHED FLOOR QTY QUANTITY SHOULD HAVE A MINIMUM OF ONE CHECKS. AFG ABOVE FINISHED GRADE RGS RIGID GALVANIZED STEEL UTILITYACCi#: 9691115504 ELECTRICIAN WHO HAS ATTENDED ASOLAR 12. FOR THE PROPER MAINTENANCE AND AWG AMERICAN WIRE GAUGE SN SOLID NEUTRAL UTILITY METERM 98357352 PHOTOVOLTAIC INSTALLATION COURSE ON SITE. ISOLATION OF THE INVERTERS REFER TO THE C CONDUIT(GENERIC TERM OF 1SWBD SWITCHBOARD DEALTYPE: SUNNOVA 5. FOR SAFETY,IT IS RECOMMENDED THAT THE ISOLATION PROCEDURES IN THE OPERATION RACEWAY,PROVIDE AS SPECIFIED) TYP TYPICAL INSTALLATION CREW ALWAYS HAVE A MANUAL. COMBINER BOX U.O.I. UNLESS OTHERWISE INDICATED MINIMUM OF TWO PERSONS WORKING 13. THE LOCATION OF PROPOSED ELECTRIC AND CB CIRCUIT WP WEATHERPROOF TOGETHER AND THAT EACH OF THE TELEPHONE UTILITIES ARE SUBJECT TO FINAL CKT CURRENT TRANSFORMER XFMR TRANSFORMER Rev.No. Sheet INSTALLATION CREW MEMBERS BE TRAINED IN APPROVAL OF THE APPROPRIATE UTILITY CT COPPER +72 MOUNT 72 INCHES TO BOTTOM OF FIRST AID AND CPR. COMPANIES AND OWNERS. CU DIRECT CURRENT ABOVE FINISHED FLOOR OR GRADE ('�A2 PV� / A16. THIS SOLAR PHOTOVOLTAIC SYSTEM I5 TO BE 14. ALL MATERIALS,WORKMANSHIP AND DC DISCONNECT SWITCHINSTALLED FOLLOWING THE CONVENTIONS OF CONSTRUCTION FOR THE SITE DISC DRAWING 1 THE NATIONAL ELECTRICAL CODE.ANY LOCAL IMPROVEMENTS SHOWN HEREIN SHALL BE DWG ELECTRICAL SYSTEM INSTALLER CODE WHICH MAY SUPERSEDE THE NEC SHALL IN ACCORDANCE WITH: EC ELECTRICAL METALLIC TUBING GOVERN. A)CURRENT PREVAILING MUNICIPAL EMT FUSIBLE SWITCH UJ L 7. ALL SYSTEM COMPONENTS TO BE INSTALLED AND/OR COUNTY SPECIFICATIONS, FS FUSE WITH THIS SYSTEM ARE TO BE"UL"LISTED.ALL STANDARDS AND REQUIREMENTS FU GROUND EQUIPMENT WILL BE NEMA 311 OUTDOOR GND GROUND FAULT INTERRUPTER FEB 1 5 2023 RATED UNLESS INDOORS. GFI FREQUENCY(CYCLES PER SECOND) -init HZ 7 ,4Tri GENERAL NOTES TOWN OFSOU-H&D SOLAR IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT. 2211 Allenwood Road 877-786-7283 Wall,New Jersey 07719 www.Trinity-Solar.com I ( NOTES:'REFER TO MODULE SPECS FOR MODULE DIMENSIONS DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE ECOFASTEN CLAMP NEW PV SOLAR MODULE,TYPICAL (REFER TO SPEC SHEET FOR DETAILS) (REFER TO EQUIPMENT SCHEDULE FOR SPECS AND QUANTITIES) I SOLAR MODULE SOLAR MODULE ♦ NEW MOUNTING FOOT/ATTACHMENT \ POINTS,TYPICAL(REFER TO ECOFASTEN"L"FOOT ECOFASTEN RAIL L5 90 ENGINEERING LETTER FOR SPACING AND Q (REFER TO SPEC SHEET FOR DETAILS) (REFER TO SPEC SHEET FOR DETAILS) o ' DETAILS) �� , _{�, �„�Q�4 NEW ECOFASTEN RAIL,TYPICAL N — �— C tQ O RPINDICULARTO EXISTING ASPHALT SHINGLEECOFASTEN FLASHING TO BE MOUNTED PEi — C) �� STRUCTURE(REFER TO ECOFASTEN S SPECIFICATION/DATA SHEET FOR DETAILS) (REFER TO ENGINEERS LETTER FOR SPECS) (REFER TO SPEC SHEET FOR DETAILS) I+'I /^ _ r z Ar•. NEW END CLIP,TYPICAL S.S.LAG BOLT APOC SEALANT01 _ (REFER TO ECOFASTEN SPECIFICATION/ (REFER TO ENGINEERS LETTER FORSPECS) ' I \ ('+'Y SOLAR MODULES SHALL NOT w —♦ — —• DATA SHEET FOR DETAILS) EXISTING RAFTER EXCEED PEAK HEIGHT. NEW MID CLIP,TYPICAL (REFER TO ENGINEERS LETTER FOR SPECS) ^ (REFER TO ECOFASTEN SPECIFICATION/ ' A t/g$61� ATTACHMENT&CLIP DETAIL DATASHEET FOR DETAILS) PV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF R�FESSl4���' SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE ARRAY SCHEDULE Issued/Revisions A2 AS-BUILT 2/8/2023 Al AS-BUILT 12/3/2022 R1 NAME 7/7/2022 Pi ISSUEOTOTOWNSHIP FOR PERMIT 6/23/2022 NO. DESCRIPTION DATE Project Title: M E R4 R3 , - - STEPHEN SCHOTT TRINITY ACCT#:2022-05-704679 Project Address: R6 w 2570 MAIN ROAD a - _ LAUREL,NY 11948 40.969282,-72.560029 a Drawing Title R5 R1 P _ - 3 _ `° P = --------- AS BUILT PV SOLAR SYSTEM E` EEEEE E tE _ EtE ErL E`t tt tt LLrE�LL j�ij - Drawing Information EEt tt g R7 `tt`LL E€t t FFEtetE LL =t I"to ttt LLL DRAWING DATE: 6/23/2022 kk t E`t`ttt `ttt E _ Ettt DC DRAWN BY: 1C REVISED BY: � Ms ttt E Lt€` ttt et Ft mm €LL�tt ttESystem Information: t_� k`k t DC SYSTEM SIZE: 12.4kW AC SYSTEM SIZE: 10kW kt DC/1'j MODULE COUNT: 31 MODULES USED: HANWHA 400 AC MODULE SPEC#: Q.PEAK DUO BLK ML-G10+400 UTILITY COMPANY: PSEG-LI ROOF 1 UTILITY ACCT#: 9691115504 MODULES:0 NOTES: PITCH:40° UTILITY METER#: 98357352 ORIENTATION:61° 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE (CONDUIT TRENCHED APPROX.60 FEET) DEALTYPE: SUNNOVA ROOF 2 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. MODULES:19 2.) ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. PITCH:37 A 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ORIENTATION:241 4.)AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S)NEC 690.13(E). Rev.N0. Sheet ROOF 3 5.)ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. MODULES: H 27 12 6.)ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. /� ORIENTATION:151 A 2 P V - 2 ROOF4 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE MODULES:0 QTY SPEC# PITCH:27*ORIENTATION:331° R7. INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE INDICATES NEW PV ONLY SUBPANEL ARRAY SCHEDULE FOR MORE INFORMATION U� INSTALLED OUTSIDE(UTILITY ACCESSIBLE) SP TO BE INSTALLED 31 HANWHA 400(Q.PEAK DUO BLK ML-G10+400) ROOF5 MODULES:0 INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SE10000H-USOOOBEi4 PITCH:34° • • ORIENTATION:331° M INDICATES EXISTING METER LOCATION INDICATE PANELSTHAT USE MICRO INVERTERS.REFER ED-C-1 INDICATES NEW DC DISCONNECT ROOF 6 `l TO EQUIPMENT SCHEDULE FOR SPECS. MODULES:0 OTHER OBSTRUCTIONS PITCH:34° INDICATES EXISTING TOUTSIDE.LECINDICATES N ELECTRICAL PANEL LOCATION: NEW PRODUCTION METER TO BE INSTALLED _T ORIENTATION:61° INDICATES EXISTING SERVICE DISCONNECT SOLAR OLA R MODULES:0 PITCH:34° INDICATES NEW INVERTER TO BE 2211 Allenwood Road 877-786-7283 ORIENTATION:241° �D IINSTALLEDNOUTSIDE(UTILITY ACCESSIBLE)BE INSTALLED OUTSIDE. TS INDICATES EXISTING TRANSFER SWITCH A REFER TO EQUIPMENT SCHEDULE FOR SPECS Wall,New Jersey 07719 www.Trinity-Solar.com t Engineer/License Holder: ARRAY CIRCUIT WIRING NOTES SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS 1. LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY 31-400W MODULES W/1 SOLAR EDGE 5440 PER MODULE FOR DETERMINING ONSITE CONDITIONS AND 15 ADC MAX PER STRING EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2017 (TOTAL) _ 1 STRING OF 9 MODULES IN SERIES-400 Vmax y-Q f I STRING OF 10 MODULES IN SERIES-400 Vmax �CFIAE( S� 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON �Q+ � e ASHRAE MINIMUM MEAN EXTREME DRY BULB 1 STRING OF 12 MODULES IN SERIES-400 Vmax O TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO `3 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT --- ---------------------------------------------- ------ 1A G TEMP=-16'C (HOUSE) C D I r Z 1 STRING OF 9 MODULES IN SERIES-400 Vmax T 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED 1 STRING OF 10 MODULES IN SERIES-400 Vmax 11' ON ASHRAE HIGHEST MONTH 2%DRY BULB `2 STRING TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 m m m m m m_ I " kL TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO 3 _ STALLATIONLOCATION. HIGHEST CONTINUOUS TEMP= (GARAGE) I I 6"x6" ---� 1 STRING OF 12 MODULES IN SERIES-400 Vmax I �J JUNCTION I �p 95675 *1 STRING TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 F I I r I BOX 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN I R��fSS IQNp~ TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED I STATES(PALM SPRINGS,CA 15 44.1°C). FOR LESS THAN 9 I CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED DC DISCONNECT I Issued/Revisions SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING I THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS I A2 AS-BUILT 1/8/2023 (ALL OF UNITED STATES) I I Al AS-BUILT 12/3/2032 5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS I R2 NAME 7/7/2022 SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT I P2 ISSUED TO TOWNSHIP FOR PERMIT 6/23/2021 CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I NEC 690.12(A)THROUGH(D) NO. DESCRIPTION DATE 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC I Project Title: SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4) 7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE I STEPHEN SCHOTT IDENTIFIED WITH THE FOLLOWING OUTER FINISH: POSITIVE CONDUCTORS=RED I TRINITY ACCT#:2022-OS-704679 NEGATIVE CONDUCTORS=BLACK EXISTING240V 10 NOTE:200 I NEC 210.5(C)(2) 10 120/240V 2 MAIN BREAKER 1 INTERNAL REVENUE GRADE MONITORING I Project Address: I UTILITY METER 200A BUSBAR CONTAINED WITHIN SOLAR EDGE INVERTER I 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV SOLAR EDGE PN.RWND-3D-240-MB WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE i 2570 MAIN ROAD I PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT I LAUREL,NY 11948 SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24"SHALL I 40.969282,-72.560029 CONTAIN 520 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN 5 9 CURRENT CARRYING CONDUCTORS. Drawing Title: 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS LOCKABLE 60A DISCONNECT INVERTER#1 OTHERWISE NOTED FUSED W/60A FUSES l/�_ 10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON 240V 10 AS BUILT PV SOLAR SYSTEM iwurE""EUML a + ROOFTOP AND SHALL BE LIMITED TO 12"IF USED m m m_00-01 OUTDOORS --- B 11.)OVERCURRENT PROTECTION FOR CONDUCTORS > ���� I Drawing Information CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE U015 FI ' ' DRAWING DATE: 6/23/2022 705 31ED WITHIN 10'OF THE POINT OF CONNECTION NEC Ll L2 N Q 1 LDRAWN BY: Jc F REVISED BY: JMS r--- --- m m m m m m - - - - - - --------------- ` -� B m 0 0 0 C------------ 12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE A UTILITY AND THE OTHER AN INVERTER,PV BACKFEED EXISTING MAIN BREAKER LOAD CENTER SQUARE Dj L"I�---------( System Information: BREAKERS)SHALL BE LOCATED OPPOSITE FROM UTILITY INSULATED LINE TAPS INSTALLED ON PN:D222NRB E_-------_J NEC 705.12(B)(2)(3)(b) MAIN FEEDERS DC SYSTEM SIZE: 12.4kW 13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY NEC 705.12(A) MODULE SYSTEM SIZE: 3U 1 GENERATION CIRCUITS AND NO UNUSED POSITIONS OR M LOADS MODULES USED: HANWHA 400 MODULE SPEC#: Q.PEAK DUO BLK ML-G10+400 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 311 RATING UTILITY COMPANY: PSEG-LI UTILITY ACCT#: 9691115504 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER#: 98357352 REQUIRED CONDUCTOR AMPACITY PER STRING DEAL TYPE: SUNNOVA [NEC 690.8(B)(1)):(15.00"1.25)1=18.75A PV MODULE SPECIFICATIONS AWG#10,DERATED AMPACITY HANWHA 400(Q.PEAK DUO BLK ML-G10+400) AMBIENT TEMP:33°C,TEMP DERATING FACrOR:.96 Rev.No. Sheet RACEWAY DERATING=6 CCC:0.80 Imp 10.77 (40'.96)0.80=30.72A Vmp 37.13 NOTE:CONDUITTYPE SHALL BE CHOSEN BYTHE INSTALLATION CONTRACTOR 30.72A'_18.75A,THEREFORE WIRE SIZE IS VALID Voc 45.3 TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS ("A2 PV 3 TOTAL AC REQUIRED CONDUCTOR AMPACITY ISc 11.14 A #6THWN-2 GEC TO EXISTING GROUND ROD G 1"CONDUIT W/2-#6THWN-2,146THWN-2,1-118THWN-2 GROUND 42.00A"1.25=52.50A B 1"CONDUIT W/246 THWN-2,1-1110 THWN-2,1410 THWN-2 GROUND H 1"PVC W/2410THWN-2,1410THWN-2 GROUND(TRENCHED APPROX.50') AWG#15,DERATED AMPACITY INVERTER#1-SE10000H-USOOOBEi4 C 1"CONDUIT W/6-#lOTHWN-2,1-#lOTHWN-2 GROUND 1 1"CONDUIT W/2-#lOTHWN-2,1410THWN-2 GROUND Tr I AMBIENT TEMP:30°C,TEMP DERATING:1.0 RACEWAY DERATING`-3 CCC:N/A DC AC 75A'1.0=75A Imp 27 Pout 10000 D 1"CONDUIT W/4410THWN-2,1410THWN-2 GROUND 1 75A'-52.50A,THEREFORE ACWIRE SIZE 15VALID Vmp 400 ]max 42 E 1"CONDUIT W/2-#6THWN-2,1-#30THWN-2,1410THWN-2 GROUND r I may CALCULATION FOR R OV 42.00 ENT PROTECTION ISc 45 Vnom 240 Voc 480 OCPDmin 52.5 F #10 PV WIRE(FREE AIR)W/#6 BARE COPPER BOND TO ARRAY SOLAR TOTAL INVERTER CURRENT:42.00A 42.00A"1.25=52.50A 2211 Allenwood Road 877-786-7283 -->60A OVERCURRENT PROTECTION 15 VALID Wall,New Jersey 07719 www.Trinity-Solar.com