Loading...
HomeMy WebLinkAbout24838-z· ~ FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-25879 Date: 08/11/98 THIS CERTIFIES that the building ALTERATION Location of Property: 750 PACIFIC ST MATTITUCK {HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 141 Block 4 Lot 24 Subdivision Filed Map No. __ Lot No. __ conforms substantially to the Application for Building Permit heretofore filed in this office dated MARCH 30, 1998 pursuant to which Building Permit No. 24838-Z dated APRIL 20, 1998 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITION AND ALTERATION TO AN EXISTING ACCESSORY BUILDING AS APPLIED FOR. The certificate is issued to TOWN OF SOUTHOLD { OWNER ) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. N 459279 07/17/98 PLUMBERS CERTIFICATION DATED 08/10/98 RICHARD W. GOELZ, JR. Rev. 1/81 Form No. {) TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY mo This application must be filled in by typewriter OR ink and submitted to the building inspector with the following: for new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and Vpre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00. Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Buiidinm - $100.00 3. Copy of Certificate of Occupancy - : 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Constructlon... ( ....... · .~.~.Old Or Pre-e~isting.~.~ '~ Building~ ........... Location of Property ............. ~ .~ ................ House No. Street Ha~et Subdivision Filed Map Lot ?' .... pe it ................................ ............... u e Of Permit Applicant . Health Dept. Approval .......................... Underwriters Approval ......................... Planning Board Approval ........................ Request for: Temporary Certificate ........... Final Certicate. ...~'~. ....... Fee Submitted: $ ~. ~. .... APPLICANT FROM : Ptnasonie FAX SYSTEM PHONE NO. : Rug. 10 1998 OJ;13PM Pi FAX TRANSMITTAL PYRAMID AIR CONDITIONING INC. 90 EAST JEFRYN BOULEVARD DEER PARK, NY 11729 Date August 10, 1998 Number of pages including cover sheet 2 To: From: Town of Southold At'tn: Jamie Richter Re: Helen M, Macchio Life Advice Education Ctr. Town of Southold Phone 765-3070 Phone 516-242~365 F~Phone 755-~750 CC: X Urgent [] For your review Reply A~P [] Please commit MESSAGE: Per our tel-con, please expedite the attached Plumber Certification as soon as possible and fax me a copy of the final C.O, (~ 516/242-4821. FAX NO'S: ADMINISTRATION / OFFICE: 516/242-4621 ENG / ESTIMATING: RUSSFJJJIMMY/LEON 516/242-5730 SERVICE DEPT: PROJECT MGT: $161242-8771 516/242-3370 85/28/1997 83:54 5162422691 py 'I~6,MID AIR CONDITIONING, INC. Ninety E. Jefryn Blvd. DEER PARK, NEWYORK 11729 PAGE 81 LETTEI OF TR ANS, MITTAL Admi.. (616) 242-3355 FAX (S18I 242.4621 TO: TOWN OF SOUTHOLD P.O. BOX 1179 SOUTItOLD. NY I 1971 wE AR~ SENDING YOU [] Shop drawings [] Copy of letter April 20, 1998 [ Jo~ no. 5697-B/G ^.rrliN'rto~: MIKE VERITY LIFE ADVICE EDUCATION CENTER SOUTHOLD. NY Attached ~ [] under separate cover via [] Prints 0 Plans [] Samples the f'ollowln8 items: [] Specifications [] Change order [] COPIES DATE NO. I Rheem Gas Horizontal Furnace Specifications THESE ARE TRANSMITTED as checked be. iow: [] For approval [] Approved as submitted CI Resubmit [] Foryouruse [] Approved as noted [] Submit [] As requested [] Returned for corrections [] Return [] For review and comment [] For },our record. [] FOR BIDS DUE 19 copies for approval copies for distribution corrected prints E] PRINTS RETURNED AFTER LOAN TO US REMARKS: COPY WIGNEI); ROBERT LAFORTE, VICE PRESIDENT $e~vlee Oe-pa~tment: Tel: $1&242,$3~0 FAX: $1&Z4Z-8771 05/28t~997 03:54 51~2422591 P~G~ 02 FOflM~NO. Gll-448 REV, SuperMde, Form No. Glf.448 Rev. FURNAC RGPH. SERIES Models with Ir~put Rates from 45,000 to 150,000 BTU/HR [13 to 44 kW] (U.S. & Canadian Models) CRITERION' Tr 800/0 A. RU.E.t UPFLOW/ HORIZONTAL GAS FURNACES The Rheem® Criterione line of upflowlhorizontal gas fur- naces are designed for utility rooms, closely, alcoves, of attica. Because of the Crllerlon'a Iow-profile 34 Inch [864 mm] height, the upflow model cen else be used to satisfy most applleetlons that tradltlonelly cell for e horl- zental turnece, Tile design Is certified by the American Gas Aasocietlon. Canadian models are certified by the Canadian Gas Association. Features · Patented Turbulexe Heat Exchanger. constructed of both stainless end aluminized sMel ~or the maximum In sion resistance. · LOW profile "34 inch" design is lighter and easier to hah. die, and leaves room tot optional equipment. · Convertible from upfk~w to tlorizonlal left or right without field conversion. · · Left or right side gsa and electric inlet connections w~th quick, simple change. · Hot surface ignition models equipped with remote sense, feature a new integrated board with humidifim and elco- tronic air cleaner hookups. · Insulated blov~r compartment, a slow-open gas ~nd a specially designed draft Inducer motor make it one of the quietest furnaces on the market today. · Pre-paint g~lvanized steel cabinet. · Molded parmanem filter, · Grab.holes ~ doors to aid in easy door removal arml replacement, A variety of csoling coils :~nd plenums designed te use with Rheetq Crilerion ga~ furnaces ere ~reailebis as optional H.S,I. model furnaces san be installed In an uptlow position or laid on either side in a horizontal position, No field verting required. 85/28/1997 03:54 516242269~ PAGE 03 In-Shel ~urflar~ and Gas Valve 9~awe~ Confrol Box RHEEM CRITERION 1T 80% UPFLOW/HORIZONTAL GAS FURNACE l'b~bulase Hall F. xdla~ grail Indulger Molar Hot $ufl~o &Driller wllh Remote Sense Inll0(lled CenlrOl Molded Permanent STANDARD EQUIPMENT main gas em~lml; blower camper tmmlt ~Or safety switch; sofld state time eeltlme of 1 blower control; limit control: manual shut-off valve, r tonsure ~ulator for Rafural and L.P. (prOpane) gas: transformer: direct drive multl-spas~ (40VA) ready for air eondltlmling Oppli~eti~s, (Please note: & ~het~$tat is not included as standard equ(pment.) Flame sensor diagnostiCS; H,SJ. only IwlanlnI epilogs; fused tmnsrdrmer (sec(m~.ry), 3~1 n~e~d fen epllae Itw cn~timaoul~ faa: ~mmeo heM/leal terminal Inf' H.$.L OPTIONAL EQUIPMENT Side filler frame assembly. Relum air cabinet for ail s~eee, (See Page 6) NOT~: Furnace is not Jlsfed for use w{Th fuels other than natural or L,~ (propane) gas, The ~ompleto lemur of limited aDO other wormlloe alt available ii our nolle All medelo can be converrnd W a qualified ~em ~stdbuTo~ or ~al ~c~ice ~Mr to as ~tl0nel aeeas~ from a Rheem pa~ d~tdbufur, ~ L.R (p~a~) ~tlon, taler to Conversion ~l ledex Fo~ No, 92.21519-~ for U.S. me~s 05/2B/1997 03:54 51G2422Ggl PAGE 04 BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE 'FROM YOUR RETAILER. C ] D~slgnate~ Metric Conversions GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacematmt for any part of this product which falls in normal use and service within the appJIcsbie period stated, in accordance with the terms of the limited wa.anty. Gas Heat Exchanger Limited Warranty .... Twenty (20) Years Draft Inducer limited Warranty ............. Five (5) Years integrated Control Board LImitea Warranty ....................... Five (5) Years Any Other Part ........................... One (1) Year 3 05/28/1997 03:54 51G2422691 PAGE 85 PHYSICAL DATA AND SPECIFICATIONS--CANADIAN MO, IELS (UPFLOW) ~[~ S~ Hr~ HiGH ~91 1391 (39~ (4al 14e R~um ~ ~T~ CI19 ~ ~ae ~wmsim ~t index Fora1 No. 92-2t619.31 far high a~oto4e 4er4t ~. (. MODEL IDENTIFICATION--UPFLOW MODELS R O P Rheem Gas Upflowl Design Furnace HoriZonlaJ Series Hot SurfaCe NO, ~t~ut & = Std. ~s~adon ~ Model BTU/H~ CabinEt U = 11 x G ~E ~N ~,~ [13kWI B=Wi~ [279 x162 mm] ~E ~N ~,~ [15kW] Cabinet M~llx7 ~E ~N 67,~ [2o k~ 1279 x 178 mm] 07~ 0TN 75,~ [22 kW} R; 11 x 10 IOE 1ON 1~,~ [29 kW[ [2~ x 2~ mmJ 12E 12N 126,~ [37kWl 15E 16N 1~,~ [44kW] [ ] Deelgnatel Metrle CMwer~(on~ Heating & Cooling Fuel Type DesignaTIMt R = Natural Cas, S -- 6o~.1500 CFM U.S. Standard (23&-866 L/si Fum~ E = 1t~-1~ CFM A = N~ ~. J519,62B Lis] G~adiue 0 = 14~-1760 CFM S~dard [~626 LIs] Furnace J ~ 18~-2075 CFM (~-979 L/si 05/28/1997 83:54 5~624~2691 PAGE UPFLOW DIMENSIONS ~i mml ~1/4~ L TABLE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm] MODEL ' REDUCED CLEARANC ,} "'~ -,.~ ... P~PH- A I C D I LEFT RIOI~ . , ,;. SHIR W~, SlOE ~t~ ~ ~ FRO~ ~t . ~,'.,~SJ ~: ~ t4 J3~] ~,~'/3z (326 .~O3/e'[~] ~ 11,h l~62] O 4 102 ~ o ~ [~] 3 7~ I 6 [152} ~ 85 [38.GJ ~, 07 t7V~ [4~] 16'/~ [¢15) ; 1~¥e 308) ~ 15 i381l 0 3 ~7GJ ~ o 1 [~J 3 [761 6 ~152[ ~ 105 [47.6] .,~O~A) ~?/~H4s] i6"/-lu5] 12'/.[~l ~ 15 [~tl 0 3 76 ~) 0 1(25J 3~6J 6([52]~ 115152.2~ 10 (e) 21 [6~J 1~7/~ [~4) 13~1, [352] · 18'/~ (4'70l 0 O O, 1 S25) 3 i?~ 6 I?SZ~ ~ ?0 [~.4I t~ 2~,/~ t~Z) ~3,,/,,~5~ ?,~1, [3~} ~ 2~ 156el 0 0 o ? l~SI ...~ ~6] 6 [162~ ~ 140 176 mini I lJ abeDlOr, May be O' IQ mmI with ty~e S vast. May be 1' [~5 mmJ ~lh type ~ ~nt. 05/2B/1997 03=54 5i62422~91 PAGE HORIZONTAL DIMENSIONS .. (82~ mm! - its mm] [~2'1 rAml TOP ViEW [1E TABLE t. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm] RGPN, ' :i, ,''" ' ., ' BIDE $il)l BACK TOP FRONT VENT 10 iA) 17~/~ (445l, 16'1~ {416l 12V. I366] ~ 15 ~1] 0 3 [76~ ~ 0 1 [~) 3 (761 G (152l ~ 115 I52.2] 10 (e) 21 (~[ 1~/= [~l 13~/e {35~] ~ 18Vf 14~0 0 0 ~,, 1 25 3 [76l 6 [lS2J ~ 1~ lS 24Va [622J 23't/~ [5~} l~Sl~ [3gll ~ ~ ~1 0 0 0 1 [26J 3 [76l 6 {t52i ~ t~ ~ NOTES: ~ May require a 3' [76 mini to 4" (102 mini er 3' 176 mini to 5" 1127 mini adorer, ~ ~y De O' [0 mmJ with ty~ 6 vefll. ~ M~y ~ 1' [25 mmJ ~tfl ty~ B ~. 'ACCESSORIES--UPFLOW PLENUM DATA FOR "A" COILS I~enum adapters are required IF) some IF)efutces for use on uprk~w applications when See Form Number C11-206 for Multi-Flex coil gals. SlOE RETURN FILTER RACK: RXGF-CA Fihor racks are shipped without fillers. Filters shipped with furnace may be used or ~ suRat~e 1 ' [Z$.4 mmJ Tilter. · DeSignates "E" or "N". RXGW. AAA01 Humidifier and Electronic Air (;leaner Accessory Board for Robertshaw Control RBCl and Honeywell ST9101A 1014 8lower Controls. NOTE: Avai)abie for standing pilot models only. RXPF-F01 and FO2 FOSSIL FUEL KIT--is for USe with Rheem Heat Pumps and Criterion warm air furnaces. RXPF-F02 meets TVA requirements. THE RXGR.C24B MAY ONLY' BE INSTA&LED ON REAR ANO LEFT StOE~. WARNINO: IMPORTANT NOTI~ A ~OLID METAL BASE FLATE ($1~ TABLE) MUST eE IN PLA~E WHEN TH,[ INSTALLED Will SIDE OR RF. AR AIR RETURN DUCTS, FAILURE TO iNSTALL PLATE COULD CAUS~ PRO3UCTS O~ COM~ 10 B£ (~RCULAT~D into THE LNiN~ SR~CE ANO CRE~T~ POTENTTALLY H/~-~RTX)U8 CONDiTiONS. ~OLIO AVNLA6[E FACTORY li~'TALLEO WffH OPTION CO~E iN. [mml KiT NO. PLATE NO, el, Imm] [ } D~etgnatee Metric Conversions 7 05/28/~997 83:54 5162422&91 PASE 89 'BLOWER PERFORMANCE DATA--UPFLOWIHORIZONTAL MOD_EtS #UMeIiR 8/~ ! mui~ Bt. OWE1 OFM[Ua)AIReEUVERY RGPH. S~ H.R ~E~ S~C PRE88U~ IN~ ~) WA~R ~EAUS' 11x6 I/~ ME0,LO ~5 (441~ ~5 427l 670 1411J 635 ~394~ 7~ [375) 7~ [~GJ 716 1337] ~N~SR (2~x1~) [3~} MHD-HI 11~ I~J T~ [522] t065 [~3] 10~ 14~J 980 (~ 936 [441J 885 [4181 HIGH 1315 (OZll ~275 [~} ,12~ I~0J 11~ [~ 1155 545J 1120 [5~gJ t0~ Z$12J LOW 675 [319J ~5 J~9] ~6 (~ 610 [268} ~ l~ 6~ 1~62J 520 ~45J 05HAUL' 11 x6 1~ MHD-LO g~ J4481 ~ Z~gJ ~ [42 9~ [415] 8~ [4~J 830 [392J ~ [378J ' OS~UER (279x152] [373J ME0,HI 1115 [526) 1~ [Sf4~ 1076 I~ 10~ ~) 1015 [479J 685 [4~J 945 J446} HIGH 1270 (5~J 112~ [5~I 1~5 {578J 12~ (~GJ 1t65 [~] ~30 [533] S065 1512) ~EAUE' LOW a~ [3671 ~ 1378~ ~ ~] 756 (356~ ?30 i~sJ 105 [~31 675 [319i ~NAUER 11 x6 1~ MHD-LO 970 [4~J ~ [4~lJ 940 [~4J 970 ~4~I ~ [415 845 J399] 8~ [380~ 07EAUE' J279x152 ~3~J MEO-HI HtO [524~ I~ 1514 1070 [~J 1~0 [dglJ 1010 14~J 9~5 [~J 93s (~1] 07NAUER HIGH ~2~ f5971 1240 585J t210 [57~J 1175 [5~1 ,11~ [5~} 11~ ~619J 1055 [498J LOW 1245 (~J 12~ [676J 11~ [~J ,1165 (~OJ 1~ [536 ~ [6~21 1~ 07EAMG' 11 X7 ~4 MHD-LO 1555 J~] 1515 [715i t475 {6~i ~t~5 [6~ 13~ ~B] 1350 [~?J 1390 J614~ 07N~R [2~x 176 I~] ~ED-~} ~810 [~4J a?~ [828~ t~ [805] 1~5 [~GJ 1585 17481 I~ (7~] 1410 HIGH ~0 [~TJ 19a5 [9311 1915 ~1 S~6 laTH 17~ [?2J 1715 {8~J 1655 ~/Z U~O-m 10~ 14~1 ~040 ]491) 1~0 [~J ~ [~ ~ [~3J 920 [~4J 8~ IONAMR [2~xlZSJ [373] MEO-HI 1220 [5~6l 1195 [~] 11~ [547i lt40 {~l 1~o~ I~) 1~ [503J 1020 HiGH 1410 [~5) 1~ [~1] ~1~5 [~J 1~ [614J 12~ [592J 1~5 i~9l 1150 [543~ LOW 1295 (611l 1215 [~2) 12~ 15~l 1225 1578J 11~ (~] ~185 [6~ 11~ 30EGR3' 11 x l0 ~4 MEO-LO 1~5 [~61 1615 [7~1 1~0 ~746J 15~ [7321 1510 (713] 14~ 1691) 1425 1673J l lONBRJR [219x2~] l~gJ MHD.HI ~46 (~ 2~ ~4) 1955 [~3~ 1~ fS~J 1845 [871] 17~ [8~el ~ ~ HIGH 23~ (~J ~ pO67J 2~ [10~] 2~ (t~5) 2~ (972] t~ i~1] ~910 LOW 1280 [~] 1275 (~J 1265 [597J 124S [~6] 1215 [573J 11~ [55~l 1145 12EARJ' 11x10 3/4 MED-~ 1~5 177GJ 1~ [~[ 1615 [762i 1~ i7~] 1~ j736~ 11520 [717J t410 [694J 12NARJR [2~9x2~1 [~} MEO-HI 2060 ~ 20~5 l~51] ~9~ i926J 1~ [913] 18~ [e~j ~5 [66~1 ~6 HIGH 2965 1116] 2310 P~I ~ P~Zi 2185 D~li ' 2U5 [~8J ' 20~ [~0J ] 1950 1920J ~W ~70 [5~J 12~ [5~] 12~ [576J 1195 (~ , 1165 {~] 1135 15~] ~11~ [522J 15EA~' 11xi0 ~4 MEO.LQ 1620 ~} 1~ [753} 1570 (741~ 1~ ~29] 1515 ~15] 14~ ~698J 1440 15NARJR ![2~X2~] {~gJ MHD-HI 2010 [949J 196~ {937J 1~0 [9251 1916 ~] 16~ i6~] ~8~ f~] 17~ JelGJ H~GR 2340 II1~) 2~5 {1074J 2215 [~GJ~ 2145 1012] ~80 [962] 2010 [949J 1~0 (9161 lien me.is. · 'NOt to be used as a healing speKI. Data compiled wit~ factory filters installed, [ ] Deaignates Metric Converilon~ lo installation Inat,uetfone paokeged - AIR OONDITIONINO with ee~h model, es wetl aS complying DIVISION "In keeping with 118 po/icy of contlnuou~ pmgm~s and p~du~t Improvement Rheem reserve~ the right to make cha~ge~ without notice~' FROM : PanaSonic FAX SYSTEM B-10-1@98 2=43PM PH(]NE FROM ALL-SUFFOLK-PJ_UM~ I NG Rug. 10 i~8 ~:14PM P2 P, 1 8-07-1998 2:63PM FROM ALL-SUFFOLK-PLUMBING 140 Gar), Way · Ronkonkoma, New York 11779 Tel: (5 !6), 467-'1919 - Fax: (516) 467-193~I AUGUST 7, 1.998 TOWN OF SOUTHOLD BUILDING DEPARTMENT REFERENCE TO PERMIT #248~8 . MATTITUCK, NY 11952 DEAR CONNIE: THIS LETTER IS TO INFOR/4 YOU T~AT TME PLUMBING AND HBATING SYSTEM AT ~"~{E ABOVE REFERENCE HAS BEEN, INSTALLED IN STRICT ACCORDANCE'TOTHE NEW YORK STATE GONSTRUCTION CODE. ALL sOLDER USED IS LEAD FREE, AS REQUIRED. IF YOU HAVE ~ OTHER QUESTIONS, PLEASE DO NOT HESITATE TO CALL. .RWG/GV B-BT-l@98 2:B3PM FROM ALL-SUFFOLK-PLUMBING 4671934 (516) 467-1919 · Fax; (516) 467-1934, DATE~ TO: PROM: FAX TRANSMITTAL PAGE'I'O~ ~ ETZ & ASSOCIATES, · A R C H ! T E C T S P.C 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION I ST [ ] FOUNDATION 2ND [ ] FRAMING [ ] ROUGH PLBG. [ ] INS~I.ATION [~NAL [ ] FIREPLACE & CHIMNEY 90 East Halsey Road · Suite 105 · Parsippany, New Jersey 07054 · (973) 428-8155 · FAX (973) 428-8270 NEW Y_ORKBOARD OF FIRE UNDERWRITERS 40 Fulton Street New York NY 10038 Tel:212 227 3700 Fax: 212 395 3740 Ray Commisso, Chief Inspector May 1, 1998 Town of Southold Office of Building Inspector Town Hall Southold NY 11971 Att: James A Richter R A Dear Sir: The following is a report of the electrical inspection requested by your letter of March 25, 1998. RE: Human Resouce Center Garage Bldg Pacific Street & Sound Avenue Mattituck NY We have complied with your request to famish you information of probable non-compliance of the electrical installation on the above property. We find the installation to be in compliance with the prevailing electrial code. Very tru~yours, Chief Inspector RC:mc £; ' ~ OF sotn~.; THE NEW YORK BOARD OF FIRE UNDERWRITERS PA E1 lllsei2 .UREAU OF ELECT.,C,TY ~- 40 FULTON STREET, NEW YORK, NY 10038 JULY 17,1998 Application No. o, file 15962198/98 N 459279 Date THIS CERTIFIES THAT only the electrical equipment as described below and introduced by the applicant named on the above appEcation number is in the premises of h~TROPOLITAN LIFE, 750 PACIFIC STREET, ~4ATTITUCK, NY in the folio)vine location; [] Basement [] 1st Fl. [] 2nd Fl. ATTIC/OUT Section Block was examined on JULY l0,1998 and found to be in compliance with the National Elecfflcal Code. Lot FIXTURES RANGES COOKING DECKS OVENS DISH WASHERS EXHAUST FANS 52 27 %8 37 5 TON A/C-2 30A DISCONNECTS-2 EXiT LIGHTS-6 MOTORS~ 2-F H.P. ,2-5 ELEC. WATER HEATERS:;I-2oO K.W. G.F.C.I:-5 I C NO. OF HI-L~G 1 310 KEANE ELECTRIC INC. LIC..~37 - GENERAL ~ANAGER ., 196A N, HAIN ST ~ '7 '~' · SAYVILLE, NY, ~1782 /'er -~-~"~'~ Th(~certificafe must not be a(tefed in any manner; retu~ to tho o~ce of the Board if incoYtect. I,spectors may bo i~flt)ed by their credentials. COPY FOR BUILDING OEPARTMENT. THIS COPY OF CERTIFICATE MUST NOT BE ALTERED iN ANY MANNER. 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST ROUGH PLBG. [ ] F/OUNDATION 2ND [ ] INSULATION FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: *~'*/~ 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 2ND [ *~~NSULATION [~RAMING ~c~ [ ]FINAL [ ] FIREPLACE & CHIMNEY DATE INSPECTOR 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I~ATION [ ] FRAMING [ ~ FINAL [ ] FIREPLACE & CHIMNEY DATE INSPECTOR "'_ ",/ ~/'. FA ,~~ /. ~ FOUNDATION INgULATION ~EB N.Y. '' STATE ENERGY CODE " ~ A SS OCI A R C H I T E C T July 31, 1998 Mr. Ga'y I:isch Building Inspector Town of Southold Building Dept. P.O. Box 1179 Southold, New York tl971 Re: Life Advice Center So athold, New York Dear Gary: As per your request, [ hereby certify that the above retErenced project was built accordance with our Construction Documents as well as all governmental roles a~d regulatioa:s including the New York State Energy Code. cc. Pram Kapadia, MetLife Bob LaForte, Pyramid Air Conditioning & Heating James A. Richter, R.A., Office of the Engineer/Town of Southold Corr/()7066/j.~ i clr PORN NO. TOWN OF SOUTIIOLD BU] LllI NG DEI'AR'I~4ENT 'I'O~{N IIAI.I. SOUTIIOLI), N.Y. 1197 I Tgi.: 765- {gO2 APPLICATION FOR Bi{ILl)lNG PERHI'F INSTRUCTIONS BOARD OF HEAl. TH ............... 3 SETS OF PLANS ............... SURVEY ........................ CHECK ......................... SEPTIC PORN ................... HOTIFY: Chl,l ................... HAIl. TO: .................... 'Date ............... 19-(~-..~ a. 'Ibis application most be co.pletely fl]led in by t~ypavriter or in ink ar~l sulxnitted to the Ihdlding T,mi~ctor wi 3 sets of plans, accurate plot plan to ~ale. F~ according to b. PloC plan ~t~ l~ti~ o~ lot ~ oE ~ildh~ ~ ~i~s, relatlou~dp to ~joinin~ pr~i~ or ~,blic d. U~ n~l o~ ~i8 n~]icaci~, t{~ Ikdldi~ ]us~ctor wil~ is~ a ~ildin~ ~mit to the applicant. ~ch {mmi~ ~all k.kep~ ~ ~m ~s ~ail~le ~or ins~ti~ thro~t the ~rk. e. ~ ~ildi~ ~mll be ~ied or ~ in ~le or in ~r~ for n~ ~ ~.IC~'FI~ IS 1~ )~ ~o tim Ikd]di~ ~rt.~a~ for the issue o[ n ~ildi~ ~m{t Drmmnt to the I~ildiu~ ~ ~i~ o[ ~1~ ~ of ~tl~ld, ~ffolk ~.~, ~ York, ~ otimr n~lienble I~8, ~db~e. or ~]oti~s, for tl~ ~8~ci~ of hdldi~s, ~i~{~ or alternuJ~s~or for ~81 or ~l{~i~, ,~scri,~. ,,. appli~= ~.s to ~ty w,~ alt a~hcal,'le l~s, ~pi~es, ~,g~, }~tug c~, 8.1 (~ili~g ~ress of a~llcmt) State ~mO~r ~lic~n~ is ~r. ]es~. ph~r .......................................................... If a~tlcuut is a co~r~ti~, ~i~re of duly m~i]~>riz~l officer. (Nare and title of corporate o[ficer) ~,ild~r8 l,lce~ ~. L)H ~gO~ ~ e PI~rs l.lcen~ ~ .......................... El~Crlci~s Lice~ ~ ...................... AC F~ ~e - }. l~uCi~ o~ ln~ ~ ~id~ pr~l ~rk ....... - ................ ~ 3. P;aure (ff ~ork (dmck ~hlch apptieahle)~ ~ l~Jildinl& .......... ~klici~ ....... MCeraci~ .~ ...... fi. Eat in~t~l ~aC (Lo Im [mid ~m ~lllng this ul~licacl~) I~ ti . . . I~i tt ~ "' , 9. 81~ ~ Iota l~lt ............. ] ....... ~ar .................... ~pth .................... lO. I~fl'e of ~ardm~ .............. -.-....__l ~ of Fon~er ~mr ........................................ 12. ~a pro~l m~at~tim violate any ~lng I~, ordb~ma or regulatt~; ..................... I]. 9ill lot Im reBr~ arddt~t ·am of C~tr~tor. ......... . · -'.-..-..,.. .... ...... ~klreaa ............................... I~ ~ .............. Iz~cate ctear]y nnd distinctly al ~d~etlmr interior or corer loC, Pi.OT DIAGRAH · bui]dinga, ~etlmr exiatin8 or proposed, and it~licata all set-lmck di~naiona (~llva of i,~ll, vid~ml, sig,~ltlg contract)[ apl)l lcation; th/it: fill statemnt, cimLbi~ in I.hia fllqilicauim: ere trim to the lest of his kix~l~ge thaC the ~rk will I~ ~rfon~l In ti? ,uu. mr ~C forth in the application fil~l tlmr~[~l. o/so kl~OWn 05 N O.R T.a former,lY Fronl~ ~ At'die or NOTES: Z ·: ~(ONU~(ENT 2, SUFFOLK CO TAX MAP D/SI: I0(:~ SECI~ I.L~ BL, ~ LOT 2~ SEPT. YOUNG & YOUNG ,)IJRcLY ) . THE tVONTH FOtEK BAtV~ ~ Tt~, ~ -~-~ ........ ~-; FT;;%.L:?,--,- =-i~;;~l:, 4;~-~!..--- · / - ~o I F~a 2, I~Zl 7/- 2, ~-'C I .......... ,I .......... -I AREA LOCATION gAP LIST OF gAWlNG8 CO E ANALYSIS DIRECTOgY ~? .~ ~.~ ~ ~ / ~ ,_, ~C~ECTU~ BUI~ING CODE: 0FFIC~ CO~I~TION OF CODES, RULE~ ~D ~_ -.-- -' - ....... ' ............. 12-29-97 A.0 CO~R SHEET ~EGU~TIONS 0F THE STATE OF NEW Y~RK {1-1-95} REQ~IRE~ 12-29-97 Al-1 S~E P~ BUID~G OCCUP~CY: C 1 - LOW ~Z~D (BUS.ESS) ~~ O~ER: ~NET?~ McKEIG~ 12-~9-97 A3-1 P~S CONSTRUCTION ~PE: ~PE 4B (ORDINARY} ~~ P~ ~ D)IRECTOR METROPOMT~ ~FE INSUR~CE COMP~Y HU~B] SERVICES 12-29-97 A4-1 SECTION ~D E~VATIONS ~~~~ I ~ISON A~NUE T0~ 0F S0~H0~ . 12-29-97 AS-1 SCHEDU~S ~D DET~ A~0~TIC SP~IN~R ESFR NOT FIRE SUPPRESSED ~ ~ ~ NEW YORK, ~ 10010 750 P~CIFIC STREET 12-29-97 AS-~ EN~GE E~VATION, SECTIONS ~D DETAILS ~ ~OWABLE ~EA: (BUS.ESS) 9,000 SF. PER T~ ~-70}5 ~$1~~ TEL. ~ (212} 578-7712 ~TTITUCK, N.Y. 11952 ~~ F~. ~ (212) 689-2209 TEL. ~ (516} 298-4460 ~C~IC~, FL~CTRIC~, PLUMB~G ~~ F~. ~ (516) 298-4462 ~..... ,~, -T ,..~** ~,~~ P-z IPLUMBING P~S, SPECS.. ~D DET~S ~ ~ON~LE HEIGHT: 2 STORY - 40'-0" PER T~ ~I-7055 ~-~ ........ ~ ~ ' a ...... r'~- 1~-29-97 4. FINAL - ~N MUST ~CHITECT M.E.P' r.~ / - ' C~S DIETZ PUSHPA ~IN ' ~ ..... ~ff~(~ s~.~. ~'L t2-29-97 M-~ H.V.A.C. SPECIFICATIONS THE REQUIREMENTS OF THE N,Y. ~ BUSINESS A~ CO~O~O~ SNA~ M[[Y DIETZ & ~SOC~TES ~ ~NGINEERING ~ ~ . ~ ~ -'- SYA~ CO~$T~O~ION · ENERGY 90 EAST ~EY RD. SUITE ~05 242 OLD NEW BR~S~CK, SUITE 330 x ~ DESIGN O~ CONSTRU~ON E~RO~S TEL. ~ (97B} 428-8155 TEL. ~ (908} 981-1270 E~ERIOR B~G W~S ........................................ 2 ~ I I COL~S (SUPPORTING ROOF) ............................. C ~,[ %~ a FLOORS ...................................................... C ~~ SOUTH0~, ~ YORK ~P~Mm~W~ ~TROP0~ ~FE ~SU~CE COMP~ DETML N~BER &~R UNES NEED SHEET NUMBER GENE~ CO~T~CTOR NOTE: ~NGBEFORE~VERING OES~e,EO~Y: I~UE (SERIES NUMBER · SEQUENT~L SHEET NUMBER' ~.8-01 THE BUI~G E~NTS SHAt.t. BE CONSTRUCTED TO MEET THE FIRE RESIS~ sc,~: .~[ T  DET~L REFERENCE ~TINCS NOTED ~0~. SHOU~ A~ DET~L OR SPECIFICATION CONFLICT wrrH ~ NO. OaTE DESCRIPTION 1/4' SIMI To c cmon. REQUIRED BEFORE ,.,..o SECTION OR DET~L REFERENCE CUP~ NYT ~'1~ RHEAD UTILITY LINE POLE -- I/2" REDLUOOD EXP. JOINT III/SEALANT. (TOP OF REDUJOOD e MIN. OF I/~u tDELOB TOP PAVING) // ~ X 2'-0" DOLUEL5 ~ 24"O.C.- BRAP ONE ENI~ W/15P FELT TYP. CONC. pA~V1NO i P. EINFOR~ING TYP. REINFORCED CONC. '-~ / I/4" X I I/4" DEEP 5ABOUT BALKS AD PER SPEC. ~, / B/SEALANT T, '"l~lll~l~l~lll~lll -- ~ - CONTROL JOINT 02 EXPANSION JOINT DETAIL 03. CONTROL JOINT AT SIDEWALK SCALE: 1" -- I-0R SCALE. I" = 1'-0" ~UHAN CENTER OVERHEAD -- UTILITY LINE EXISTING MONUMENT 51GN MATTITUCK PRES,15TTERIAN C~U~SH EXISTING AREA FINISH P-~MP BROOM FINISH CONCP-,ETE 04 HANDICAP RAMP DETAIL PUMP [] SCALE: 114" = 1'-0" PARKING ;R 1-~ ASI # 840 DION. 12" x 18% 51ON. GRADE WYDR~NT EXISTIN~ pAR~ING AREA NEUJ STRIPPIN~ 2ONC. SIDEUJALK- -- LANDSCAPE -- AREA EXISTIN~ MASONRY BLDG. PflOPPODED LIFE ADVICE EDUCA TICN CENTER SET TUE~ES LEVEL AND PLUME~ IN ~" DIA. CONCRETE PIEr,S 05 HANDICAP :SIGN DETAIL SCALE: I" = I-0" CONCRE CURB TELEPHONE BOX ELECTRIC METER NI3'D2'UJ -- 1,11' O1 SCALE: I" SITE [] 201-0II PLAN O 5 I~ 20 DIETZ & AS$OCIATES,P.C. A R C H I T E C T S 90 East Halsey Road · Suite tO§ · Parsippany, New Jersey 07054 · (201) 428-8155 · FAX (~Ol) 426-§270 DIB'Z ~ ASSOCIATES, ?,C, DI[TZ & ~SSOCIATES, P.C. DESIGNED BY:~ NO. DRAWN BY: CHECKED BY= CPD APPROVED BY: CPi:) LIFE ADVICE EDUCATION CENTER SOUTHOLD, NEW YORK l DE~LOPI~T OF METROPOLITAN LIFE I~SURANCE COMPANY SCALE: AS NO~-O DATE OESCRIPTION 12-29-97 19SUED FOR ~ AND PEFIMIT8 DATE: 12-29-97 SHEET NO,: AH JOB NUMBER= 97066 SHEET NO. A1-1 &'-0" 26'-0" 2~'-0" 14'-0" 12'-0" C2D ¢ ~41 CANOPY ABOVE - ,1, C25 Il 4 AR41 II II I1( <~> II II ACCT. REP. LUOM MEN HANDICAP TOILET C~AT CLOSET LODDY RECEPTION MEDIA CENTER F~ VIDEO PACK -- 50" HIGH 5¥STEM FUI~ITURE BITH IIlOOP CAP 5UN ROOM LITERATURE CRED P STAIf~ TACK BOARD CREDENZA ACCT. REP. OPEN AREA 44 MEN WANDICAo TOILE'T COAT CLOSET MEDIA CENTER 4~'" BIDE VISUAL M(tTORIZED PROJECTION O1 FLOOR PLAN 02 REFLECTED CEILING PLAN 03 POWER/FIXTURE PLAN SC:ALE: 1/4" = T-~ SCALE: 1/4" 1'-O" SCALE: 1/4" -- 1'-O" PARTITION TYPES NEB D/g," THK. G.LUJ~,. (FIRECODE 'C') ON BOTH 51DE5 OF 3 5/8," TFIK. (25 GA.) METAL STUDS e I&" D.C. EXTEND UP TO UNDERSIDE OF STRUCTURE SAME AS PI EXCEPT PROVIDE 5/8" TN~ MOISTURE REDIST~T O.~.B ON INTERIOR 51DE ~ TOILET ROOH NE~ 5/~" TH~ G.~. (FIRECODE 'C') ON ONE 51DE OF 3 D/~" TH~ (25 ~A.) HETAL STUD5 e I&" D.C. EXTEND UP TO UNDERDIDE ~ STRUCTURE 5AHE AG ~ EXCEPT PRO~[DE 5/~" TH~ ~OIGTU~ ~515TANT G.~.~ NEB S/~'," THK. G.B.B. (FIRE. CODE 'C') ON 2 I/2" TH~ (25 GA.,) METAL STUDS e I&" D.C. ON EXISTING CJ'I.U. BALL, EXTEND METAL STUDS TO UNDERSIDE OF EXIST'G STRUCTURE AND G.LU.B. TO CEILING HEIGHT SAME AS P3 EXCEPT PROVIDE S/~," THK. MOISTURE RESISTANT G.B.B ON INTERIOR SIDE OF TOILET ROOM AND INSTALL AND SUPPLY 2" RIGID INSULATION e ALL PERIMETER BALLS NEB 5/~" TH~ O.B.e. ON 2 I/2" THK. LUD. STUD5 e l&" D.C. ON NEUJ ~," TWl<. CJ'I.U. UJALL. NEB 5/~," THK. G.UJ.B. (FIRECODE 'C') ON 2 I/2 THK.. (25 GA.) METAL STUD5 e I&" D.C. ON NEB ~," THK. C.M.U. BALL. NEB S/~" THK. G.LU~. (FIRECODE 'C') ON 2X4 BP. STUDS e I&" D.C. EXTEND UP AND FRAME TO UNDERSIDE OF NEB BP. RAFTERS WALL LEGEND EXISTING LUALL TO REMAIN EXISTING BALL TO BE f~EMO~=D NEB pARTITION CEILING PLAN LEGENDS NEB 2' x 4' FLUORESCENT LIGHT FIXTURE. NE~J DOU~ LIGWT NEB 2' X 2' FLUORESCENT LIGHT FIXTURE NEB EXIT SIGN NEB BALL UJASH FIXTURE ELECTRICAL SYMBOLS O NEB DUPLEX OUTLET e 15" AFJ=. UNO. NEB COME~INATION - TEL. AND DATA OUTLET 15" A.F.F:. UNO. NEB LIGHT SBITCH NEB THERMOSTAT OD DUPLEX OUTLET DEDICATED CIRCUIT. JUNCTION BOX IN CEILING NELU C~UAD OUTLET TELEPHONE OUTLET. 15" AFF ~ GROUND FAULT INTERUPT OUTLET k'~Gj=J GENERAL NOTES NOT USED NOT USED NOT USED NELU 2 I/2" METAL OTUD AND 5/~," GYP. DP. ENCLOSURE AROUND EXISTING LALLY COLUMN NOT U6ED NE~ ~OD DOOR ~ITH 6IDELITE6 ~OOD COLU~ ON PEDESTAL DECORAT{~ LISHT FIXTU~ NOT USED ~HO~ EXIST'~ ELEC, ~ANEL. SEE ELEC. ~HO~ EXIST'~ CLG. HUNG UNIT HEATE~ SEE HECH~IC~ D~5. ~HO~ ALL EXISTIN5 LIGHT FIXTU~5. CAP ALL ELECTRICAL LINE5 ~HO~ EXISTIN~ O.H. DO0~, T~CKS, ETC.. IN IT5 ENTI~TT REMOVE EXISTING N.M. DOOR FPAME REMOVE EXISTIN~ CPt. U BALL REMOVE EXISTING STUD PARTITION IN ITS ENTIRETY DIETZ & ASSOCIATES,P.C. A R C H I T E C T S 00 E~t Halsey Road · Suite 105 · Parsippan~, New Jersey 07054 · (201) 428-8155 · FAX ({0l) 428-8270 I LIFE ADVICE DIETZ & ASSOCIATES, B.C. EDUCATION CENTER m~:~5~m:.~,,=, SOUTHOLD,i D[!~RLOPIi~iT IqEw oF YOI{K D[~ ~ ASSOC]4TRS, P.C. I~ETROPOLITAI{ LIFE ~qSURANCE COldPAIqY D£SIGNED BY: I~=tt=:~U ~ LOG CPO .o.DATE DESCRIPTION 1/4'-1'-0' SHEETNO. D,AW. BY: 2-29-97 18SUED FOR ~ AND PEF~IIT8 RG 12-29-97 CPD 97066 TOP OF PLATE -- NEW ASNPALT SHINGLE5 TOP OF PLATE (ATTIC) ASNPALT SHINGLE5 EXISTING UJOOD 51DING TO E,E PAINTED REMOVE EXISTING '~ PATCH ROOF SEE MECHANICAL D~. TOP OF PLATE (ATTIC) TOP OF 5UE~FL (ATTIC) -- TOP OF PLATI APPROX. FIN. ~EADE LUOOD 51DINd -- (PAINTED) TOP OF 5WE,FL (ATTIC) TOP OF CUE,FL (ATTIC) CEILING LINE PLATE (ATTIC) - T TOP OF PLATE (ATTIC) PAINTED EXISTING J LIFE ADVICE < ', =4 _, E,LocK EDUCATION CENTER SIGNAGE ~ r DOWNSPOUT PAINT EXISTING E,LOCK. COLOR AS SELECTED E'Y ARCHITECT. DECORATIVE -- WOOD SHINGLES / APPROX. FIN. GRADE PAINT TOP OF SUE, FL dST FLOOR) TOP OF / ~ TOP OF SUBFL dST FLOOR) UJoOD DOOR BIT ~ APPROX. FIN. GRADE EXISTING. ~L~.. METER SIDE LITE- ~ CEI'IlENT ~ r-EXISTING DOU, NSPOUT TO BE P, ELOCATED. ~_L ....... ~ ..................... SEE ELECT. DLU~S. i NEB C.M.U. BALL i .............. ~- .......................... -- cEMENT PARGING AND PAINT PAINT UJOOD COLUMNS ON O1 FRONT ELEVATION 0g RIG,I-IT SIDE ELEVATION SCALE: 1i4" = ¢-¢" 5CAKE: 114 = 1'-O" TOP OF PLATE (ATTIC) TOP OF SUE,FL (ATTIC) TOP OF PLATE (ATTIC) APPROX. FIN. GRADE TOP OF SUE,FL dST FLOOR) ~..,_~ PAINT EXISTING E,LOCK '~ EXISTING WOOD SHINGLES TO E'E PAINTED TOP OF PLATE (ATTIC) TOP OF SUt~FL (ATTIC) TOP OF PLATE (ATTIC) APPROX. FIN. GRADE TOP OF SUE,FL dST FLOOR) O4 REAR ELEVATION 5GALE: I/4" = 1'-O" EXISTING [UOOP SHINGLES TO E,E PAINTED 5HIINGLES LUOOD SIDING~ APPROX. FIN. GRADE TOP OF SUEFL (1ST FLOOR) O3 LEFT SIDE SCALE: 1/4" = 1'-O" ELEVATION L,,~(CEMENT PA'RGING AND PAINT fNEUJ CJ'l.U. (UALL PAINT EXISTING BLO)CK. COLOR AS 5ELECTED E~T AtRCWITECT. (2) I I/2" X II 'liS" MICRO-LAN HEADER -- NEW 2X& WP. RAFTERS e I&" O.C. W/8" R-I'=J BATT INSUL. S/8" THK. G.UJ.E' OVER 2X4 STUDS e 1~" O,C. IL!/ 3 I/2" R-13 E,ATT 12 NEUJ DROP CEILING '-518" THK,. G.W.E' OVER 2x4 WP. STUD5 ~ IA" [U/2 I/2" R-13 lNG RAFTER5 ~ JOIST TO RErIAIN LUALL (REF. TO e TYPE.) EXISTING g," THK, C.M,U UJALL ADD 5" E,ATT INSULATION IN EX/STING RAFTERS TOP OF PLATE (ATTIC) EXISTING ATTIC R-13 E,ATT INSUL. IN ALL UJALLS NEUJ DROP CEILING EXICTING FIRST FLOOR TOP OF SUE,FL (ATTIC) CEIL'G 8 -O- A.F~=. TOP ¢ ~L (1ST FL~, AP~OX. FIN. ~DE EXIST. PIER E,EYOND O5 BUILDING SCALE: 1/4"-' 1'-O" SECTION DIETZ & ASSOCIATES,P.C. I 90 Baal Hal~ey Road · A R C H I T B C T S Suite 105 · Parsippany, New Jersey 07054 · (201) 428-8155 · FA][ (201) 428-8270 ~©~ DIgIZ & ASSOCIAIZS, P.C. DI~I*Z k ASSOCIATES, P.C. LIFE ADVICE EDUCATION CENTER SOUTItOLD, NEW YORK A DE~ELOP[I~iT OF METROPOLITA~ LIFE ]~SURANCE COMPANY DRAWN BY: CHECKED BY: CPD APPROVED BY: CPD DESCRIPTION ISSUED FOR BID~ AND PERMR'8 DATE: 12-29-97 SHEET NO.: A4-1 JOB NUMBER= 97066 SHEET NO. A4-1 01 FINISH SCHEDULE CEIL'G WALLS CEIL'G REMARKS NO. NAME FLOOR BASE N s E to HT. ~AISED PANEL SOLID COPE 04 DOOR ~ISED pANEL BOOD DOOR TYPES 02 DOOR SCHEDULE DOOR FRAME REMARKS HARDWARE SET NO. TYP~ SIZE MATERfAI. FINISH MATERIAL FINISH DETAIL 03 FINISHES FL,OOf~ CAfRPET NoJ 514A~J NIG~VE CARPET NoJ 5N~ p~ACE OUA~ vINYL H~I~TON 5ASR CA~ET ~.1 ~ NIO~ CA~ET ~ $NA~ P~E VINYL H~I~T~ CEILING5 ~I-LE O~I~A ~ ~ CLX. ~lT~ 51L~ET - 8LOTTE~ - aAs" ~ITE GRID CASE pLASTIC LAMINATE ~lcA ~m~ - ~lX coPE TE~PE~D LITE TEMPEPED --- GLA55 LiTE TYPE 'E' DOOR & HARDWARE NOTES FLOOR FINISH NOTES GENERAL NOTES MILLWORK NOTES DRYWAI.L CONSTRUCTION NOTES WINDO~ TREATMENT NOTES ABBREVIATIONS 1/4 = .'-_ oN METAL STUD eA~,r R3~ ~NE ~R E~TI~ ~ ~ETI~ ~ ~ ~ ELEV. ELEVATI~ DOOR (~FER TO SCHEDULE) ON ~L NE~ O~5 ?ALL ON METAL STUD DO~ (~PER TO ~NEDULE) ~ ~ ~D ~ER ~ THE ~OR'$ ~EO ~ FEC FI~ E~I~I~R C~I~T ON EXISTG CM.U ~ALL %" ~ OTP. BD ~ DOOR 3- z TH~ MTL. STUD5 ~ ~ ,~,,  ~OD CASI~NG CM.U ~EE BALL I¢. ,~< n~m '~' DET. 'B' DET DET. 'E' EXISTING ~DOD JOIST5 UNDERSIDE OF EXISTING PROVIDE FIRE E, LK'G ,e CLG. LINE NEB CEILING t-HOUR FIPE RATED pARTITION A5 PER U.L. - "U4~5. INDICATES NEB GYP. ED, PARTITION TO BOTTOM OF DECK,.. (ONE LATER OF 5/~," THICK,, FIRECODE 'C' GYP. SD. ON EACH 51DE OF 3 5/~" THK. MTL. STUD5 e I&" O.C.P FLOOR AND 15A~E A5 SCHEDULED. TYPE 'PI' UNDERSIDE OF EXISTING PROVIDE FIRE BLK'G e OLD. LINE NE~J CEILIIA3 ONE LAYER OF 5/8" TF~,. GYP. BP. ON ONE SIDE OF 4" TNtC ~JOOD STUD5 e l&" O.C. ON EXISTING CYi.U BALL.. EXTEND UP AND F~E TO U~E~5IDE ~ NE~ ~OOP ~AFTE~5 PARTITION P-& -- NEB CEILING 25. 2&. 2'3. 06 PARTITION SCALE: Y': 1'-0" ONE LAYER OF 5/~," THK. GYP. E~D. ON ONE 61DE OF 3 S/~II THK. METAL STUD5 e l&" D.C. ON EXISTING C]"l.U BALL. EXTEND STUDS TO UNDERSIDE OF EXISTING STRUCTURE AND G.t~.E~ TO CEILING HEIGHT FLOOR AND ESASE A5 SCHEDULED, DETAILS TYPE 'P2' TYPE" P3" SIMILAR TO ABOVE WITH 2 1/g' STUD AT 16" 0.C. EXIST'G g," TH~ C~JJ BALL FLOOR AND E, ASE A5 SCHEDULED. TYPE 'P6' & TYPE 'P3' PARTITION BETWEEN SUN ROOM AND OPEN /AREA ONE LATER OF 5/~," THK. GYP. t~D. ON oNE 51DE OF 2 I/2" TNIC METAL STUD5 e 18" D.C. ON:EXiSTING CJ'I.U UJALL EXTEND UP TO TOP OF &" CJd.U. BALL PARTITION FLOOR AND E, ASE A5 SCHEDULED. I/ DIETZ & ASSOCIATES,P.C. A R C H I T E C T S 00 East Halsey Road · Suite 105 · pamippany, New Jer,ey 07054 · (201) 428-8155 · FAX (~0t) 4~8-8270 D~ a ~S0mUS, P.C. ME~0P0~T~ UFE [NS~CE COMP~ DESIGN[D BY: 188UR LOG o~w. BY= 1~7 ~ ~R a~ ~D ~ DATE= ~ A~1 ~ 97~ NO. 1/4" r SEE TOILET PLAN L UNDERSIDE C~: CEILING 18" X 3~o" MIRROR INSULATE ALL EXPOSED PIPE5 UNDER 5INK-. ELEVATION 1 BEE TOILET PLAN UNDERSIDE OF CEILING ELEVATION 2 SEE TOILET PLAN f L UNDERSIDE OF CEILINO MIRROR ALL~ INSULATE EXPOSED PIPES UNDER SlNtC ELEVATION 3 ," TI-~K. HTL, STUD5 ~ lb" ON C:ENTE~ E~OLT5 PER PIF~ P. EQUII~=NENT5 COVE~ PLATE5 < ~" UJD. 15LO~KIN~ BAP.5 01ENLARGED TOILET PLAN 02 ENLARGED TOILET ELEVATION 03. H,ANDICAP GRAB BAR SCALE: 1/4" , I'-O" 5GALE: I/2": l-O" SCALE. 3" = I-OR TRIM PROVIDE HETAL STR, ApPINO ENTIRE LENGTH C~: CABINETS. = AND BOTTOH CLEAT). PLASTIC L ON 3/4" PLYWD, TYP, ROLLER K ~ V BRAcK-,F. TS ~ -- RECESSED STANDARDS SHELVING WI NARDLUOOD EDGES. 11 ,"TNK. BIRCNPLYWOOD 1" 1'-0" PAINTED, TYP. TRIM1 // [> ' OUAD []< PLASTIC LAHINATE COUNTERTOP WI BACK SPLASN. LINE <DF EXIBTINO PARTITION PROVIDE METAL STP-,~PPINO LENOTN C~: CABINETS. 2" x 4" CONT. CLEAT e BACK ,~ SIDE WALLS. K ~ V ~CKET5 ~CE55ED CONT. HI~E ~D. '4" PLY~D ~FER TO FINISH SCHEDULE. ,f:,NELLVIN~ ovEERHEAD CAESlNETS HIC~O~AVE (N.I.C.) rOE COUNTER T~P STAIIIN. 5TL. SINK ]( DUPLEX FOR HICROWAvE IN CABINET BEYOND AFF. DUPLEX FOR BEYOND TH~PAINTED PLTWOOD X 4" PAINTED WOOD BLOCK'G DR~CKET ~ ROD-- I" X 2" PAINTED -- WOOD BLOCK'G EXIBTI~ DVP. OvER HTL. STUDS FINISHED FLOOR KITCHENETTE 04. CABINETSECTION 05 CABINET ELEVATION 06 ?HELF & ROD DET. SCALE. I"= I'-O" SCALE: I/2" = I'-~)" SCALE:- I'-O" // DIETZ & ASSOCIATES,P.C. A R C H I T E C T S 90 East Halsey Road * Suite 105 * Par~ippany, ~lew Jersey 07054 · (201) 428-8155 · FAX (gOt) 428-8270 ~""~- LIFE ADVICE DI~IZ & ASSOCIATES, P,C. ,~,.~..~'='-""=--~.-,--- EDUCATION CENTER ~,,~ SO~HO~, ~ YORK D~SlO,[D BY: IBBUE LO0 II ~ NO. DATE ] DESCRIPTION II ~12-~97 ~ED ~ B~ ~ ~ DATE: DRAWN BY: ~ 12-~7 CHECKED BY: ~ SHE~A~2 APPROVED BY: ~ g7~6 LUMBING SPECIFICATIONS THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL OF THE OF THE NATIONAL STANDARD PLUMBING CODE. SECTIONS CLEANUP AND FINAL CHECK OF SYSTEMS - PLUMBING CONTRACTOR SHALL CLEAN ALL FIXTURES AND EXPOSED TOILET PIPING, TEST FOR ALL OPERATIONAL, ADJUST AS NECESSARY AND SUBMIT TO OWNER A COMPLETE OPERATIONAL SYSTEM. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEANING OF ALL FLOOR SURFACES OF ANY DEBRIS OR OIL FROM THE OVERHEAD PLU, MBING OR GAS LINES INSTALLED. PLUMBING CONTRACTOR SHALL ARRANGE FOR ALL PLUMBING INSPECTIONS AT THE SITE DURING THE INSTALLATION AND COMPLY WITH ALL CODE REQUIREMENTS AS TO TESTS AND INSPECTIONS TO INSURE ISSURANCE OF A CERTIFICATE OF OCCUPANCY WITH REFERENCE TO THE PLUMBING WORK. PLUMBING SYMBOL LIST SYMBOL ABBREVIATION DESCRIPTION S. OR W. SOIL OR WASTE PIPING ........ V. VENT PIPNG C.W. COLD WA'rER PIPING H.W. HOT WATER PIPING -- G-- G GAS PIPING --~ G.C. GAS COCK C.O.D.P. CLEANOUT W/DECK PLATE P-No. FIXTURE TYPE PROVIDE OWNER WITH A WRI'FFEN GUARANTEE ON ALL SYSTEMS INSTALLED UNDER THIS CONTRACT, FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE OF THE SYSTEMS. GUARANTEE TO COVER ALL EQUIPMENT, PIPING, FIXTURES AND ACCESSORIES INSTALLED ON THIS PROJECT. SUBMIT THE FOLLOWING SHOP DRAWINGS OR MATERIALS DATA TO THE ARCHITECT FOR APPROVAL BEFORE INSTALLATION OF THE ITEMS: FIXTURES & TRIM INSULATION FIXTURES CARRIERS WATER HEATER VACUUM BREAKER PIPE/FITtINGS CONTRACTOR MUST VISIT SITE TO REVIEW EXISTING CONDITIONS AND GENERALLY REVIEW THE INTERIOR CONDITIONS OF THE BUILDING. NOTES: 1. CUTTING AND PATCHING OF FLOOR BY PLUMBING CONTRACTOR. FINAL FINISH BY GENERAL CONTRACTOR. 2. ALL PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE 1995 ISSUE OF THE NATIONAL STANDARD PLUMBING CODE. 5. ALL GAS PIPING SHALL BE INS'TALLEB IN ACCORDANCE WITH THE B.O.O.A. MECHANICAL CODE 1993. C.O.D.P. ' H. &C.W. 1 1/2" W. UP H.&C.W. 1 1/2" V. DN. THE NEW FIXTURE INSTALLATIONS WILL REQUIRE CUTTING OF THE FLOOR SLAB TO INSTALL THE NEW DRAINAGE PIPING. PIPING INSTALLED UNDER THIS PLUMBING CONTRACT SHALL BE NEW, AND OF THE FOLLOWING MATERIALS: SANITARY AND VENT HOT AND COLD WATER GAS PIPING WATER SERVICE VALVES GAS COCKS NO HUB IRON WITH NO HUB STAINLESS STEEL COUPLINGS ABOVE GRADE AND r-SEAL COUPLINGS ON ALL PIPING BELOW THE SLAB OR GRADE. - TYPE 'L' COPPER WITH WROUGHT COPPER FITTINGS, SOLDERED WITH 95/5 LEAD FREE SOLDER. SCHEDULE 40 BLACK STEEL SCREWED PIPE WITH SCREWED MALLABLE FITTINGS. ALL VALVES SHALL BE BRASS, BALL TYPE, CONBRACO OR EQUAL. - ALL GAS COCKS SHALL BE BRASS AND AMERICAN MADE,CONBRACO OR EQUAL. CLEANOUTS SHALL BE J.R. SMITH FIG. 4020 DUCO CAST IRON BODY WITH 4" DIA. ADJUSTABLE SCORIATED SECURED NICKEL BRONZE TOP. WATER HAMMER ARRESTOR SHALL BE J.R. SMITH "HYDROTROL" FIG. 5005 P.D.I. VALVES - FURNISH AND INSTALL STOP VALVES AS NOTED ON DRAWING FLUS VALVES AT EACH FIXTURE, ALL EXPOSED VALVES, PIPE AND FI~INGS IN THE TOILET AREAS SHALL BE CHROME PLATED. PROVIDE CHROME PLATED ESCUTCHEON PLATES FOR ALL EXPOSED PIPING PASSING THRU WALLS OR CEILINGS. ROOF VENT PENETRATION - ALL NEW ROOF VENT PENETRATIONS FOR ANY NEW VENT PIPING SHALL BE MADE BY THE PLUMBING CONTRACTOR, USING APPROVED SLEEVES FLASHED INTO THE ROOF AND WEATHER TIGHT. PROVIDE SUPPORT FOR ALL VENTS AT THE ROOF. SUPPORT ALL COPPER HOT AND COLD WATER LINES WITH COPPER PLATED HANGERS IF THE HANGER IS IN CONTACT WITH THE PIPE. PIPE HANGERS SHALL BE MAXIMUM OF 6'-0" APART USING 5/8" PLATED OR PAINTED THREADED ROD AND MEfAL HANGERS. PIPE INSULATION - INSULATE ALL HOT AND COLD WATER PIPES WITH 1" THICK FIBERGLAS INSULATION, UNIVERSAL WHITE JACKET BANDED, NOT STAPLED. INSULATE ALL FITTINGS WITH 1" THICK FIBERGLAS TIED ON AND FINISHED WITH PRE FORMED FIRE RATED PLASTIC COVERS OR AN APPROVED MASTIC FINISH. FOIL TAPE ON THE FITTINGS WILL NOT BE PERMII i ED. ALL INSULATION MATERIALS SHALL HAVE A SMOKE RATING OF 50 OR LESS AND A FLAME SPREAD RATING OF 25 OR LESS. INSULATE ALL EXPOSED HOT WATER PIPING AND TRAP/DRAIN PIPING UNDER EACH HANDICAP LAVATORY. 4"-% D.D.P. F 1" WATER P-2 1" C.W. UP W/BALL VALVE IN RISER 1/2" H. & C.W. 1 1/2" W. UP H. & C.W. 1 1/2" W. UP P-1 S. P-1 S. C.W. UP UP "C.W. UP --- ON GRADE V. UP 1 1/2" DRAIN 1" GAS UP GAS METER AND SERVICE BY OTHERS FIRED HVAC UNIT IN ATTIC 1" GAS F IN ATrlC SHOCK-- CONTROLLER G DN. "C.W. DN. 1/2" H.&C.W. 1 1/2" V. DN. 2"V. ~ I"- ELECTRIC ATER HEATER- WiTH DRAI PAN IN A"FrlC SPACE ABO~/E. PROVIDE SHUT OFF VALVES iN H.&C.W. CC~NNECTION. RUN RELIEF~ VALVE DISCHARGE FTO DRAIN PAN, J 1/2" H.&C.W. 1 1/2" V. DN. 1/2" CONTROLLER C.W. DN. V. DN. & THRU ROOF 1/2" DRAIN DN. GAS DH. UP PLUMBING FIXTURES P-1 WATER CLOSET: AMERICAN STANDARD 2254~015 "MADERA EL 1.6". SIPHON ACTION ELONGATED VITREOUS CHINA BOWL, 1.6 GALLON PER FLUSH; OLSONITE #95 OPEN FRONT SEAT LESS COVER.; SLOAN ROYAL #111 LOWER PLUMBING FLUSH VALVE. SCALE: 1/4" = 1'-0" P-2 LAVATORY (HANDICAPPED): AMERICAN STANDARD: 9141.011 VITREOUS CHINA WALL HUNG WHEELCHAIR LAVATORY; 7400.172H CENTERSET FAUCET WITH WRIST BLADE HANDLES; 7723.018 DRAIN ASSEMBLY; J.R. SMITH FIG. 700-27-M31 FIXTURE SUPPORT. P-3 KITCHEN SINK: ELKAY NO. LR-1517-6WH 18 GAUGE; TYPE 502; SELF JId"VENT fHRU ROOF RIM STAINLESS STEEL SINK; SPEAKMAN NO. SC-5785 POLISHED CHROME FAUCET WITH 6" WRIST HANDLES. WATER HEATER F A1TIC FLOOR 10 GALLON STORAGE, ELECTRIC GLASS LINED "A.O. SMITH" WATER HEATER I MOD. NO. DEL-lO OR EQUAL HAVING ONE 1500 WATr ELEMENT, 120 VOLT, SINGLE PHASE. FURNISH AND INSTALL ON WATER HEATER A WATFS RELIEF 1-1/2%j__ ~ AND VACUUM VALVE TO MEET CODE REQUIREMENTS. ELECTRICAL 2" CONNECTIONS BY ELECTRICAL CONTRACTOR. WARRANTY PERIOD SHALL BE NO LESS THAN 5 YEARS FROM INSTALLATION DATE. I F- -J L ~ % .1-1/2" ii ,. III1#0T1~¢/,:¢.~<¢ PLUMBING 1-1/2" T 1-1/2' T t t 1-1/2" T I' 5'-0' TESTING BEPORE COVERING NODFY IUILOINO ~E(~F AT P-5 I P-2 I P-2I -- ' '- 1, FOUNI~IEION - ~ REQUIRED P-1 P-1 ,o.,oumo ONa. ---I I s. mSULA~ON ON/-EAD CONTENT8EFORE 1 COP 1 1 COOP 4. FINAL - CONBTRUC'IION MUST L L I BECOM~-~FO~C.O. CERTIFICATE OF OCCLIPAIVCY I, l' ' ALL CON~T.UC110" SHAIl MEET ,~.IL%1% 1% ~.~ THE REQUIREMENTS OF I~IE N.Y. SOLDER USED IN WATER " STATE CON~rRUCT~ON · ENERGY SUPPLY SYSTEM C~NNOT DESIGN OR CONSTRUCTION ENRORS E,,C E~.D z, ~ ~ o~ 1 ,o LEAD. 3" 4" 4" 4-" RISER DIAGRAM NOT 10 SCALE P LAN //- ROOF VACUJUM RELIEF~....,..~ r~ _ ~ ~---BALL VALVIE n ~ ~j~-'-~. ,.. VALVES .... , ....... ~ 3/4' ~;L~i~b. ~bLIbF~~ ~ ELEC. WATER HEATER ii ,. ,,I I, ,, H . / / t I , LSEE NOTE¢ 1 t" ' I ~MAIN SHUT OFF VALVE WITH ACCESS DOOR WATER RISER DIAGRAM NOT TO SCALE NOTE: SHOCK CONTROLLER "J.R. SMITH" MODEL No. 5005 AMIN ENGINEERING PROJECT # 802 e AMIN ENGINEERING, P.C. CONSULTING ENGINEERS 242 OLD NEW BRUNSWICK ROAD SUITE #330 P~SCATAWAY, NEW JERSEY 08855 (908) 981-1270 PUSHPAVATI AMIN P.E. N.~Y. PROFESSIONAL ENGINEER LIC. No. 58477 UPPER PLUMBING PLAN SCALE: 1/4"= 1'-0" O0 East Hibey Road * Suite 105 · Parutpptn~, New Jeruey 07054 · (201) 428'-f~15~ · FAX (~Ot) 428-8270 LIFE ADVICE ,,,, OR EDUCATION CENTER REPRODUCe, mN ~ FORM, ,u,~os~. W~OUT w.~ SO~O~, N~ YO~ D~ ~ ~, P.C. ~ D~P~ 0r ~OPODT~ ~ ~S~CE CO~ DESIGN BY: iSSUE LOG SCALE: R.E.M, NO D~ D~GR*~ON 1/4" =f--o" DRAWN BY: ~ ,2-~-o~ *SsuED FOR ~*DDiN~ DATE: R.L. 12-30-97 CHECKED BY: SHE~ NO: R.E.M. p-~ APPROVED BY: ~OB NUBBER P.A. 97066 CHARLES P. DIEfZ SHEET NO. ELECTRICAL SPECIFICATIONS GENERAL: ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, TOOLS. EQUIPMENT, SERVICES AND LABOR REQUIRED FOR THE EXECUTION OF ALL ELECTRICAL WORK SPECIFIED HEREIN AND SHOWN ON THE DRAWINGS. THE ITEMS OF WORK ARE: A) DEMOLITION OF EXISTING ELECTRICAL LIGHTING FIXTURES AND DEVICES; B) NEW ELECTRIC SERVICE; C) NEW LIGHTING; D) NEW RECEPTACLES; E) WIRING OF EQUIPMENT FURNISHED BY OTHERS. CODES: ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE NEC AND LOCAL, STATE AND OTHER APPLICABLE CODES AND ORDINANCES. CONTRACTOR SHALL APPLY FOR AND OBTAIN ALL PRELIMINARYAND FINAL INSPECTION CERTIFICATES FROM THE LOCAL CODE ENFORCEMENT AUTHORITIES. ALL FEES FOR OBTAINING SUCH CERTIFICATES SHALL BE PAID BY THE CONTRACTOR. SHOP DRAWINGS: MATERIALS FOR WHICH SHOP DRAWINGS ARE TO BE SUBMITrED ARE: 1. LIGHTING FIXTURES 2. PANELBOARDS AS BUILTS: CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF ASBUILT RECORD DRAWINGS INDICATING CIRCUITS BEING USED IN EXISTING PANELS AND WORK PERFORMED. UPON COMPLETION OF PROJECT, A SET OF AS-BUILT DRAWINGS SHALL BE GIVEN TO THE OWNER FOR THEIR RECORDS, GROUNDING: GROUNDING CONNECTIONS SHALL BE PROVIDED AS REQUIRED BY THE NATIONAL ELECTRICAL CODE OR AS SPECIFICALLY INDICATED ON THE DRAWINGS FOR ALL GROUNDED DISTRIBUTION SYSTEMS, CONDUITS, PANELS AND ALL METALLIC PARTS OF APPLIANCES ENCLOSING 'LIVE' ELECTRICAL WIRING AND/OR PARTS. ELECTRIC SERVICE: EXISTING ELECTRIC SERVICE TO THE BUILDING SHALL BE DISCONNECTED AND REMOVE. CONTRACTOR SHALL PROVIDE A NEW 120/208 VOLT, 5 PHASE, 4 WIRE, 200 AMP UNDERGROUND SERVICE TO THE BUILDING. CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND COORDINATING NEW ELECTRIC SERVICE AND ALL RELATED WORK WITH THE LOCAL POWER COMPANY. ALL FEES FOR OBTAINING THE SERVICE SHALL BE PAID BY THE CONTRACTOR. RACEWAYS: CONDUIT INSTALLED OUTSIDE OF THE BUILDING SHALL BE RIGID GALVANIZED STEEL. CONDUIT INSTALLED INSIDE THE BUILDING SHALL BE E.M.T. THINWALL CONDUIT UNLESS OTHERWISE NOTED. CONDUIT MAY BE EXPOSED IN ANY UNFINISHED AREA, ON UNDERSIDE OF ANY EXPOSED ROOF CONSTRUCTION, AND IN HUNG CEILINGS. ALL OTHER AREAS SHALL HAVE CONCEALED CONDUIT. WIRES AND CABLES: ALL WIRES AND CABLE SHALL BE INSTALLED IN CONDUIT, EXCEPT WHERE OTHERWISE SPECIFIED AND SHALL CONFORM TO THE LATEST STANDARDS OF THE CURRENT EDITION OF N.E.C. AND SHALL MEET ALL IPCEA AND NEMA SPECIFICATIONS. WIRE AND CABLE SHALL BE COLOR CODED, WITH A SEPARATE COLOR FOR EACH PHASE AND NEUTRAL USED CONSISTENTLY THROUGHOUT THE SYSTEM AS PER N.E.C. NOTE THE GREEN COLOR CODING REQUIRED BY N.E.C. FOR GROUNDING CONDUCTORS INTENDED SOLEY FOR GROUNDING PURPOSES. WIRE AND CABLE SHALL BE AS MANUFACTURED BY TRIANGLE, CABLEC, OR EQUAL. BRANCH CIRCUIT CONDUCTORS SHALL BE COPPER CONDUCTORS WITH 600 VOLT, THHN 90 DEGREE OR THWN INSULATION MINIMUM SIZE #12 FOR POWER WIRING. WIRE SIZE #10 AND SMALLER SHALL BE SOLID AND #8 AND LARGER SHALL BE STRANDED. NO ALUMINUM CONDUCTORS WILL BE PERMITTED. AS FAR AS PRACTICABLE, ALL CONDUCTORS SHALL BE CONTINUOUS FROM ORIGIN TO PANEL TERMINATIONS WITHOUT RUNNING SPLICES IN INTERMEDIATE PULL BOXES OR SPLICING CHAMBERS. SUFFICIENT SLACK SHALL BE LEFT AT THE TERMINATIONS TO MAKE PROPER CONNECTIONS. SPLICES OF WIRE #10 AND SMALLER SHALL BE MADE WITH IDEAL WING TYPE WIRE NUTS, BUCHANAN PRESSURE CONNECTIONS, OR T & B STAKON WIRE JOINTS. WIRE SIZES #8 AND LARGER SHALL BE MADE WITH PRESSURE TYPE CONNECTORS ONLY WITH AN EQUIVALENT INSULATION OF PLASTIC ELECTRICAL 'PFPE. DISCONNECT SWITCHES: MOTOR DISCONNECTS WHERE REQUIRED BY CODE AND/OR INDICATED ON THE DRAWINGS SHALL BE STANDARD DUTY (UP TO 2¢0V) KNIFE BLADE SWITCHES IN PROPER NEMA TYPE ENCLOSURE AND OF CAPACITY REQUIRED. MANUFACTURERS SHALL BE WESTINGHOUSE, GENERAL ELECTRIC, SQUARE D OR EQUAL. 10. RECEPTACLES AND SWITCHES: 11. OUTLET BOXES: ALL OUTLET BOXES SHALL BE STANDARD GALVANIZED ST. EEL TYPE, AT LEAST 1-1/2" DEEP, SINGLE OR GANG STYLE TYPE OF SIZE TO ACCOMMODATE DEVICES REQUIRED. BOXES SHALL BE EQUIPPED WITH PLASTER RING OR OTHER COVER AS NECESSARY. TOGGLE SWITCHES: UNLESS OTHERWISE NOTED, TOGGLE SWITCHES 'SHALL BE 20 AMPERE, 277 VOLT, AC QUIET TYPE ROCKER ACTION AND SPECIFICATION GRADE THROUGHOUT. TOGGLE SWITCHES SHALL BE MANUFACTURED BY LEVITON HUBBELL OR APPROVED EQUAL. DIMMER SWITCHES: SUDE DIMMER SWITCH, WITH POSITIVE ON/OFF SWITCHING CONTACTS, LEVITON 6621-1 OR EQUAL. DUPLEX RECEPTACLES, GENERAL USE: 15A-125V, 2 POLE, 3 WIRE GROUNDING TYPE UNLESS OTHERWISE NOTED. THESE SHALL BE SPECIFICATION GRADE, HUBBELL #5262 OR EQUAL. COORDINATE THE COLOR OF THE DEVICES WITH THE ARCHITECT. PLATES FOR DEVICES IN FLUSH BOXES: IVORY FINISHED. PANELBOARDS: WHERE SHOWN ON THE PLANS, INDICATED IN THE RISER DIAGRAM, OR LISTED IN THE PANELBOARD SCHEDULE, FURNISH AND INSTALL POWER PANELS OF THE TYPE AND SIZES NOTED. PANELS SHALL BE INSTALLED WITH TOP OF CABINET 6 FEET, 6 INCHES ABOVE FLOOR LEVEL, BUS BARS SHALL BE COPPER WITH EQUIPMENT GROUND BAR. PANELBOARDS SHALL BE OF THE CIRCUIT BREAKER, DEAD-FRONT TYPE AND EQUIPPED WITH THERMAL MAGNETIC CIRCUIT BREAKER BRANCHES OF SIZES AND TYPE NOTED ON THE DRAWINGS OR INDICATED IN THE PANELBOARD SCHEDULE. CABINET DOORS SHALL BE EQUIPPED WITH LATCHES AND LOCKS, AND ALL LOCKS SHALL BE KEYED ALIKE. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE 'D' OR EQUAL. 12 NAMEPLATES AND SCHEDULE: FURNISH AND INSTALL LAMACOID FASTENED ON OUTSIDE OF DOOR OF ALL PANELS, DESIGNATING THEM AS LIGHTING AND/OR RECEPTACLE PANEL. ALL PANELS FOR LIGHTING AND/OR RECEPTACLE OR POWER SHALL BE SO DESIGNATED, CLEARLY INDICATING THEIR OPERATING VOLTAGES. 13. LIGHTING FIXTURES AND LAMPS: ALL FIXTURES SHALL BE COMPLETE WITH LAMPS, BALLASTS, STARTERS AND OTHER NECESSARY EQUIPMENT. ALL FIXTURE SHALL BEAR THE LABEL OF THE UNDERWRITER'S LABORATORIES. FLUORESCENT FIXTURE BALLAST SHALL BE OF THE TYPE COMPATIBLE FOR LAMPS, WITH THERMAL PROTECTION FOR BOTH THE COIL AND CAPACITOR, LTL-CMN APPROVED, HIGH POWER FACTOR, AS MANUFACTURED BY UNIVERSAL, ADVANCE, OR GENERAL ELECTRIC. BALLASTS SHALL BE IN ACCORDANCE WITH U.L LATEST REQUIREMENTS REGARDING "CLASS P" BALLASTS, Ar'ID THE LIGHTING FIXTURE- BALLAST COMBINATION SHALL RESULT IN AN OPERATING BALLAST CASE TEMPERATURE NOT TO EXCEED ,90- DEGREES. WHEN ACRYLIC DIFFUSERS ARE SPECIFIED ON LIGHTING FIXTURE SCHEDULE, THE ACRYLIC ISHALL BE 100% VIRGIN ACRYLIC THROUGHOUT. NO ADULTERATIOIN BY SWRENE OR OTHER PLASTIC WILL BE PERMIWED. SYMBOL LIST CONDUIT RUN CONCEALED IN CEILING OR WALLS. TWO WIRE CIRCUIT SHOWN, Ill ,3 WIRES, Im 4 WIRES, ETC. CONDUIT RUN EXPOSED CONDUIT RUN CONCEALED IN FLOOR OR UNDERGROUND ,,} FLUORESCENT LIGHTING FIXTURE FLUORESCENT LIGHTING FIXTURE: "NORMAL" AND "NIGHT/EMERGENCY" INCANDESCENT OR H.I.D. (RECESSED OR SURFACE INCANDESCENT OR H.I.D. (WALL MOUNTED) LIGHTING FIXTURE MOUNTED) LIGHTING FIXTURE EXIT LIGHT EMERGENCY BATTERY MOUNTED HEADS REMOTE HEAD FIXTURE TYPE FIXTURE WATTAGE PACK WITH TWO UNIT SEE LIGHTING FIXTURE SCHEDULE FOR COMPLETE DESCRIPTION RECEPTACLE PANEL -SURF. MT'D, SPECIAL PANEL AS NOTED MOTOR - ,3 PHASE 208V. U.O.N.- NUMBER INDICATES H.P. MOTOR - 1 PHASE 120V, U.O.N.- NUMBER INDICATES H.P. MANUAL MOTOR STARTER lO E] SD SAFETY DISCONNECT SWITCH- UNFUSED- NUMBER IS SWITCH SIZE SAFETY DISCONNECT SWITCH - FUSED - NUMBER IS FUSE SIZE TOGGLE SW. SINGLE POLE USED AS DISCONNECT ON 120V.-1 PHASE EQT, JUNCTION AND/OR PULL BOX S S3 S4 Sp Ds E.C. A.F.F. U.O.N. N.T.S. TOGGLE SWITCH - SINGLE POLE TOGGLE SWITCH - THREE WAY TOGGLE SWITCH - FOUR WAY TOGGLE SWITCH WITH PLOT LIGHT DIMMER SWITCH 44" A.F.F.-U.O.N. DUPLEX RECEPTACLE - FLUSH MT'D. (~18" A.F.F.-U.O.N. SUBSCRIPT 'G' - INDICATES G.F.C.I. TYPE SUBSCRIPT 'AC' - INDICATES MOUNTED 6" ABOVE COUNTER TELEPHONE OUTLET, FLUSH MT'D, ~18" A.F.F.-U.O.N. RUN `3/4" E.C. FROM OUTLET TO ABOVE HUNG CEILING WEATHERPROOF EMPTY CONDUIT ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED NOT TO SCALE 250 MCM, 2 1/2"C ELECTRIC METER PANEL RP 4 # 250 MGM TYPE "USE" DIRECT BURIAL ALUMINUM CONDUCTORS FOR 120/208 VOLT, 3 PHASE, 4 WIRE, 200 AMP UNDERGROUND ELECTRIC SERVICE TO NEAREST UTILITY POLE UNDERGROUk WATER PIPE 4 GND WIRE X lOFT LONG COPPER CLAD STEEL GROUND ROD POWER RISER DIAGRAM N.T.S. CONCRETE CURB POLE NYT 678 OVERHEAD UTILITY LINE HYDRANT C{~RETE 7],7' AMIN ENGINEERING PROdECT # 802 AMIN ENOINEERINO, CONSULTING ENGINEERS 242 OLD NEW BRUNSWICK ROAD SUITE #33O PISCATAWAY, NEW JERSEY 08855 (908) 981-'f270 PUSHPAVATI AMIN p]Y. PROFESSI?NAL ENGINEER LIC, TELEPHONE BOX ELECTRIC METER POLE UTILITY LINE HUMAN RESOURCE CENTER EXISTING PARKING AREA EXISTING NEW STRIPPING PARKING AREA MATTITUCK PRESBYTERIAN CHURCH GAS PUMP / LAND~CAPE NEW 200 AMP PROPPOSED LIFE ADVICE EDUCATION CENTER ROOM/ ELECTRIC METER UNDERGROUND ELECTRIC SERVICETO UTILITY POLE. REFER TO POWER SHALL COORDINATE ROUTING OF LOCAL POWER COMPANY. SUN NEAREST RISER DIAGRAM. CONTRACTOR ELECTRIC SERVICE WITH THE ELECTRICAL SITE PLAN SCALE:I" = 20'-0" 0 5' 10' 20' 40' DIETZ & ASSOCIATES,P C A R C H I T E C T S O0 East Halsey Road * Suite 105 · Parsippany, New Jersey 07054 · (eOt) 428-8155 *FAI (~1) 4,28-81~70 P.O. P.e. No. 58477 CO~S£NT FRO~ DISTZ & ASSOCIATES, P.C, DESIGN BY: J R.L. NO DRAWN BY: R.L. CHECKED BY: P.A, APPROVED BY: P.A. LIFE ADVICE EDUCATION CENTER SOUTHOLD, NEW YORK A b~VELOPI~I~T OF MlffROPOLITAN LIFE INSIJK~CE COMP,~IY ISSUE LOG SCALE: 1/¢ :r-o" DATE: 12-30-97 SHEET NO: E-1 JOB NUMBER 97066 CHARLES P. DIETZ A~RCHFFF_CT DATE: SIGNED SHEET NO. UN ROOM ! INOTE ;#2 RP- TC- SUN OPEN AREA 104 RP-52 WP,GFCl RP-451~) NOTE RR-1 (NOTE #21 15 VIA~ i(NOTE #2) RP-1 +15"A.F.F. )RP-3 + 15"A.F.F. (]~)UON ROOM RPN-:J 8 -~ RP-,20-< RP-'22 -8 RP-6~ RF~-8 FOR i RP~4 PARTIAL FLOOR PLAN SCALE: 1/4" = 1'-0" RP-29,51,33 -- NOTE #2 -TO LIGHT FIXTURES A~]'IC IN ELECTRIC METER -EXISTING ELECRIC METER (NOTE #3) FLOOR PLAN(NOTE #3) SCALE: 1/4"= 1'-0" AREA 108 REP'(~NOTE #1 KITCHENLITE ~3Ao)NOTE #1 107 G, A.C:. -~ F.F. +1 NOTE #2 MENS TOILIET q~ U.O.N. 105 WOMENS T(OILETFq,~]'~ U 0 N. lO5 L¢5 / ' · 'Dsc' 2EPTION ~ UON. 101/102! ~ (NOTE #1) ~P~20 .103 CENTER ~1)~ UON. !NOTE OP JGHT FIXTURE IN~__~% r RP-54 U PANEL RP - RP-`30 MOTORIZED DAMPER AIR HANDLER SMOKE DETECTOR r RP-24 TO 'Sp' Oh FIRST FLOOR RP-26 .I >1 RP-32-(~ r FAN EF-1 ATDC (~ ~ELECTRIC WATER HEATER ATTIC PLAN(NOTE #4) SCALE: 1/4" = 1'-0" LOBBY. RECEPTION LTG. 1 ~ MEDIA CENTER LTG. ,.3 ,,--,,_ OPEN AREA. OFFICE LTG5 ,,--'-, SUN ROOM LIGHTING 7 SPARE 9 SPARE 11~/'---..._ MEDIA DOWN LTG. 15~,~-',, _.. SPARE 15,---,,, MICROWAVE 17/'~ REFRIGERATOR 19~,,--'-, _ .. MOTORIZED SCREEN 21,.---, AIR HANDLER -- ~'' ACCU- 1 /55A SPARE SPARE 57~'~, SPARE 59A I 5P-200 AMP ~ 2 ___/-'-.4 ~ 6 /--.10 · _. ~ 1~6 /--,18 ~-~2~0 .--,28 ~--,50 /--.,34 ,~-, 40 r-,42 COPIER RECEPT OPEN AREA RECEPT OFFICE RECEPT KITCH. RECEPT SECRETARY DESK RECEPT MEDIA REC. RECEPT MEDIA, UNDERCOUNTER MEDIA UNDERCOUNTER COMP. RECEPT COMP. RECEPT COMP, RECEPT EF-1 WATER HEATER DUCT FURNACE DUCT SMOKE DET./DAMPER MOTOR ATTIC/EXTERIOR RECEPT. ATRC LIGHTING SPARE SPARE SPARE SPARE RECEPT RECEPT PANEL RP 120/208 VOLT 3 PHASE, 4 WIRE, 225 AMP MAINS 5P-200 AMP MAIN BREAKER, SURFACE CABINET, 1P-20 AMP BREAKERS, U.O.N., PANEL SHALL BE SUITABLE FOR SERVICE ENTRANCE AND SHALL BE LABELLED ACCORDINGLY AMIN ® LIGHTING FIXTURE SCHEDULE ]YPE DESCRIPTION A. 2'x4' RECESSED PARABOLIC, 4 F32T8/SPX`35 LAMPS, STEEL HOUSING AND DOOR FRAME, SPRING LOADED LATCHES, `3" DEEP `32 CELL SEMI-SPECULAR SILVER LOUVER, ENERGY SAVING ELECTRONIC BALLAST (TWO 2 LAMP BALLAST FOR DOUBLE SWITCHING), 120 VOLTS, FIXTURE SHALL BE SUITABLE FOR GRID CEILING. H.E. WILLIAMS CAT. # USG-D24-4520C-48S-(2)-E2520C/120 OR EQUAL AS SELECTED BY THE CONTRACTOR. 2'x4' RECESSED PARABOLIC, 5 F52T8/SPX55 LAMPS, STEEL HOUSING AND DOOR FRAME, SPRING LOADED LATCHES, 3" Al. DEEP 18 CELL SEMI-SPECULAR SILVER LOUVER, ENERGY SAVING ELECTRONIC BALLAST (ONE 2 LAMP AND ONE 1 LAMP BALLAST FOR DOUBLE SWITCHING), 120 VOLTS, FIXTURE SHALL BE SUITABLE FOR GRID CEILINGS. H.E. WILLIAMS CAT. # USG-D24-5320C-56S-(2)-E2320C/120 OR EQUAL AS SELECTED BY THE CONTRACTOR. A2. 2'x4' RECESSED PARABOLIC, 2 F32TG/SPX35 LAMPS, STEEL HOUSING AND DOOR FRAME, SPRING LOADED LATCHES, 5" DEEP 12 CELL SEMI-SPECULAR SILVER LOUVER, ENERGY SAVING ELECTRONIC BALLAST (ONE 2 LAMP BALLAST), 120 VOLTS, FIXTURE SHALL BE SUITABLE FOR GRID CEILING. H.E. WILLIAMS CAT. # USG-D24-2520C-26S-(1)-E2520C/120 OR EQUAL AS SELECTED BY THE CONTRACTOR. AS. 2'x4' RECESSED PARABOLIC, 5 F`32T8/SPX55 LAMPS, STEEL HOUSING AND DOOR FRAME, SPRING LOADED LATCHES, 5" DEEP 18 CELL SEMI-SPECULAR SILVER LOUVER, ENERGY SAVING ELECTRONIC BALLAST (ONE 2 LAMP AND ONE 1 LAMP BALLAST FOR DOUBLE SWITCHING), 120 VOLTS, FIXTURE SHALL BE SUITABLE FOR GRID CEILINGS, FIXTURE SHALL HAVE SELF CONTAINED EMERGENCY BATFERY UNIT TO PROVIDE ONE LAMP WITH 90 MINUTES OF EMERGENCY POWER. H.E. WILLIAMS CAT. # USG-D24-3520C-56S-(2)-E2`320C/120-EM/B100 OR EQUAL AS SELECTED BY THE CONTRACTOR. A4. 2'x4' RECESSED PARABOLIC, 2 F52TG/SPX55 LAMPS, STEEL HOUSING AND DOOR FRAME, SPRING LOADED LATCHES, 5" DEEP 12 CELL SEMI-SPECULAR SILVER LOUVER, ENERGY SAVING ELECTRONIC BALLAST (ONE 2 LAMP BALLAST), 120 VOLTS, FIXTURE SHALL BE SUITABLE FOR GRID CEILING, FIXTURE SHALL HAVE SELF CONTAINED EMERGENCY BATTERY UNIT TO PROVIDE ONE LAMP WITH 90 MINUTES OF EMERGENCY POWER. H.E. WILLIAMS CAT. # USG-D24-2320C-26S-(1)-E2520C/120-EM/B100 OR EQUAL AS SELECTED BY THE CONTRACTOR. AS. 2'x4' RECESSED PARABOLIC, 4 F52TG/SPX55 LAMPS, STEEL HOUSING AND DOOR FRAME, SPRING LOADED LATCHES, 5" DEEP .32 CELL SEMI-SPECULAR SILVER LOUVER, ENERGY SAVING ELECTRONIC BALLAST (TWO 2 LAMP BALLAST), 120 VOLTS, FIXTURE SHALL BE SUITABLE FOR GRID CEILINGS, FIXTURE SHALL HAVE SELF CONTAINED EMERGENCY BATrERY UNIT TO PROVIDE ONE LAMP WITH 90 MINUTES OF EMERGENCY POWER. H.E. WILLIAMS CAT. # U3G-D24-4520C-48S-(2)-E2520C/120-EM/B100 OR EQUAL AS SELECTED BY THE CONTRACTOR. B. 2'x2' RECESSED PARABOLIC, 2 F31T8U/SPX55 LAMPS, STEEL HOUSING AND DOOR FRAME, SPRING LOADED LATCHES, `3" E. J. L. L1. M. N. DEEP 9 CELL SEMI-SPECULAR SILVER LOUVER, ENERGY SAVING VOLTS, FIXTURE SHALL BE SUITABLE FOR GRID CEILING. H.E. WILLIAMS CAT. # U3G-D22-2310C-3`3S-(1)-E2510C/120 DOWNLIGHT, 75 WATT A-19 INCANDESCENT LAMP, 6" DIAMETER ELECTRONIC BALLAST (ONE 2 LAMP BALLAST), 120 OR EQUAL AS SELECTED BY THE CONTRACTOR. REFLECTOR AND TRIM RING WITH ALZAK ALUMINUM FINISH, STEEL HOUSING, ADJUSTABLE MOUNTING BRACKETS, PRE-WIRED JUNCTION BOX, 120 VOLTS. STAFF CAT. # `360-36251CL-9956 OR EQUAL AS SELECTED BY THE CONTRACTOR. WALLWASH DOWNLIGHT, 75 WATF A-19 INCANDESCENT LAMP, 6" DIAMETER WALLWASH REFLECTOR AND TRIM RING WITH ALZAK ALUMINUM FINISH, STEEL HOUSING, ADJUSTABLE MOUNTING BRACKETS, PRE-WIRED JUNCTION BOX, 120 VOLTS. STAFF CAT. # `361-36152CL-9956 OR EQUAL AS SELECTED BY THE CONTRACTOR. SELF-CONTAINED EXIT LIGHT, 6" HIGH RED STENCIL LblIERS, HIGH INTENSITY L.E.D. LAMPS, ALUMINUM HOUSING, BLACK FINISH, BRUSHED ALUMINUM FACE, MAINTENANCE FREE LEAD BA~FERY TO PROVIDE 90 MINUTES OF EMERGENCY POWER, SOLID STATE BATTERY CHARGER, LOW VOLTAGE DISCONNECT, TEST SWITCH, READY LIGHT, UNIVERSAL MOUNTING, 120 VOLTS (CONTRACTOR IS RESPONSIBLE FOR ORDERING SINGLE OR DOUBLE FACE EXIT SIGNS AS SHOWN ON THE PLAN) EMERGI-LITE CAT. #LEDPXL-X-R-EI OR EQUAL AS SELECTED BY THE CONTRACTOR. EXTERIOR PENDANT MOUNTED LIGHTING FIXTURE, 100 WA~ METAL HALIDE LAMP, ALUMINUM AND STEEL COMPONENTS, GASKETED POLYCARBONATE LAMP COMPARTMENT, SUSPENDED FROM AIRCRAFT CABLE, REMOTE BALLAST SUITABLE FOR WET LOCATIONS, 120 VOLTS, WHITE FINISH. POULSEN CAT. # ORP-MAX-598-WHITE. SURFACE MOUNTED LIGHTING FIXTURE, 2 F32TG/SPX35 LAMPS, STEEL HOUSING AND END CAPS, CLEAR PRISMATIC WRAP-AROUND LENS, ENERGY SAVING ELECTRONIC BALLAST, 120 VOLTS, WHITE FINISH. H.E. WILLIAMS CAT. # 17-4-2320C-A-(1)E2520C-120 OR APPROVED EQUAL. SURFACE MOUNTED UGHTING FIXTURE, 2 F32TG/SPX55 LAMPS, STEEL HOUSING AND END CAPS, CLEAR PRISMATIC WRAP-AROUND LENS, ENERGY SAVING ELECTRONIC BALLAST, 120 VOLTS, WHITE FINISH, FIXTURE SHALL HAVE SELF-CONTAINED EMERGENCY BATTERY UNIT TO PROVIDE 90 MINUTES OF EMERGENCY POWER. H.E. WILLIAMS CAT. # 17-4-2320C-A-(1)E2320C-120-EM/BlO0 OR APPROVED EQUAIL. TWIN WEATHERPROOF ADJUSTABLE LIGHTING HEAD, GASKETED ALUMINUM CANOPY, 12 VOLT, 9 WA~F LAMPS, WHITE FINISH. EMERGt-LITE CAT. # EF11D(IE) OR APPROVED EQUAL. RECESSED EMERGENCY BATTERY UNIT TO POWER REMOTE HEADS, NO UNIT MOUNTED HEADS, STEEL HOUSING, WHITE FINISH, 12 VOLT, 36 WATT SEALED NICKEL CADMIUM BATFERY TO PROVIDE 90 MINUTES OF EMERGENCY POWER, TEST SWITCH, READY LIGHT, 15 MINUTE TIME DELAY. EMERGI-LITE CAT. # 12TSC56-O-TD(15)-120V OR APPROVED EQUAL. NOTES: FLUORESCENT LIGHTING FIXTURES IN ROOMS INDICATED WITH THIS NOTE SHALL HAVE DOUBLE SWITCHING. ONE SWITCH SHALL CONTROL THE TWO OUTER LAMPS AND THE SECOND SWITCH SHALL CONTROL THIE INNER LAMP(S). CONTRACTOR SHALL PROVIDE THE REQUIRED NUMBER OF BALLASTS IN EACH LIGHTING FIXTURE. 2. CONNECT EMERGENCY BATTERY UNIT TO UNSWITCHED HOT LEG OF NORMAL LIGHTING CIRCUIT SERVING THE AREA. ALL, EXISTING LIGHTING, RECEPTACLES AND ELECTRIC EQUIPMENT SHALL BE DISCONNECTED AND REMOVED. EXISTING ELECTRIC METER AND SERVICE SHALL BE DISCONNECTED AND REMOVED. ENGINEERING PROJECT # 802 AMIN ENOINEERINO, P.C. CONSULTING ENGINEERS 242 OLD NEW BRUNSWICK ROAD SUITE #350 PISCATAWAY, NEW JERSEY 08855 (908) 981-1270 PUSHPAVATI AMIN P.E. PROFESSIONAL ENGINfER UC. No. 58477 I I DIETZ & ASSO,CIATES,P C ~ R C ff I T I~ C T 90 E~et Halsey Road · Suite 105 · peilippany, New Jersey 07054 · ('~01) 4~6-8155 · FAX (,SOl) 428-8,~70 CHARLES P. DIETZ DIE'I*Z & ASSOCIATES, DESIGN BY: R.L DRAWN BY: CHECKED BY: P.A. APPROVED BY: P.A. LIFE ADVICE EDUCATION CENTER SOIYlItO~, ~ YORK A I~vsLOPMff~IT OF M~TROPOLITAN Ig~ INSURANCE COMPANY DATE ISSUE LOG DE:SCRIPT]ON ISSUD FOR BIDDING SCALE: 1/4" :1'-0' DATE: 12-,30-97 SHEET NO: E-2 JOB NUMBEF 97066 SHEET NO.