Loading...
HomeMy WebLinkAbout46991-Z F 0 Town of Southold 4/22/2023 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44041 Date: 4/22/2023 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 1300 Long Creek Dr, Southold SCTM#: 473889 Sec/Block/Lot: 55.4-12 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/5/2021 pursuant to which Building Permit No. 46991 dated 10/18/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations and outdoor shower to existing single-family dwelling as applied for. The certificate is issued to Finegan,Lisa of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46991 1/4/2023 PLUMBERS CERTIFICATION DATED 1/26/2023 C�t\hogu�Eat P-H lnq� Au o 0 ized e "Foc,F TOWN OF SOUTHOLD �Sofr � BUILDING DEPARTMENT C IN TOWN CLERK'S OFFICE oy�o �o� ti SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 46991 Date: 10/18/2021 Permission is hereby granted to: Finegan, Lisa 1300 Long Creek Dr Southold, NY 11971 To: construct alterations and outdoor shower to existing single-family dwelling as applied for. At premises located at: 1300 Long Creek Dr, Southold SCTM #473889 Sec/Block/Lot# 55.4-12 Pursuant to application dated 10/5/2021 and approved by the Building Inspector. To expire on 4/19/2023. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $516.00 CO-ALTERATION TO DWELLING $50.00 Total: $566.00 ui or pv SOUIyOIo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.deviina-town.southold.ny.us Southold,NY 11971-0959 �yC4UNT1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Lisa Finegan Address: 1300 Long Creek Dr city:Southold st: NY zip: 11971 Building Permit* 46991 Section: 55 Block: 4 Lot: 12 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Peconic Power Systems ' License No: 45056ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service X Commerical Outdoor X 1st Floor X Pool New Renovation X 2nd Floor X Hot Tub Addition Survey Attic X Garage X INVENTORY Service 1 ph X Heat Duplec Recpt 59 Ceiling Fixtures 20 Bath Exhaust Fan 3 Service 3 ph Hot Water Gas GFCI Recpt 5 Wall Fixtures 11 Smoke Detectors 4 Main Panel 200A A/C Condenser 1 Single Recpt Recessed Fixtures 53 CO2 Detectors Sub Panel A/C Blower 1 Range Recpt Gas Ceiling Fan Combo Smoke/CO 3 Transfer Switch UC Lights Dryer Recpt G8S Emergency Strobe Heat Detectors 2 Disconnect Switches 43 Z LED 2 Exit Fixtures 11 Sump Pump Other Equipment: Fridge, Dual Fuel Oven, DW, Micro, W/D Gas and Elec., 200A 42Circuit/ 31 Used Notes: Two Story Inspector Signature: Date: January 4, 2023 S.Devlin-Cert Electrical Compliance Form Town Hall Annex Telephone(631)765-1802 54375 Main Road : Fax(631)765-9502 P.O.Box 1179 ' �? Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF BOUTHOLD JAN 2 �Z23 D . t5UILUINU DEPT C .R T-1 F I C A I 1 N TOWN OFSOUTHOLD Date: J 2 3 Building Permit No. 1 .117 Owner- 1-1 rNe ah (Please print) Plumber:. CC _..�2� �C�6 -_C J�jC1 �.... (Please print) I certify that the solder used in the water supply system contains less than 2110 of I% lead. (Plumbers Signature) Sworn to before me this ,day ofU"20 aj CONNIE D.BUNCH Notary Public,State of New York lam _ No. 01BU6185050 Qualified in Suffolk County Commission Expires April 14,2 Notary Public, .testy I,� OF SOUly�lo - -- `��� * # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPEC ION [ ] FOUNDATION 1ST [ ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: -P W L07 Q IZ-V— n tD�OkiZL U — ov— , DATE Iy Y INSPECTOR ho�,oF SOUIyo� 'A # # TOWN OF SOUTHOLD BUILDINdDEPT. °ycoum" 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) `[l,<DELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR ` qWjq ��OF SOUTyO� # # TOWN OF SOUTHOLD BUILDING DEPT. courm 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] PKULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMRKS: &6,4 't �,t%, DATE I INSPECTOR r N. J. MAZZAFERRO, P.E. PO Box 57, Greenport,N.Y. 11944 Phone- 516-457-5596 Consulting Engineer August 4, 2022 Design, Construction, Inspection Town of Southold-Building Department 53095 Main Road Southold NY 11971 �J Re: Residential Alterations n 1300 Long Creek Drive D V Southold,N.Y., 11971 District-1000, Section-55.,Block-4, Lot-126 A U 0 - 4 2022 Building Permit Number-46991 -Alterations BUILDING DEPT. TOWN OF SOITIHOLD, Inspection-Insulation On 8/2/22, I inspected the insulation installed at the noted location. The inspection covered the alterations to the existing structure. The inspection results are: 1 -Walls-Insulation provided and installed by TNT Insulation. Insulation provided rated as R-21. The insulation provided was done in compliance with the applicable sections of the IRC,NYS and Southold Town Building Codes for an existing structure. ,1 2-Ceiling-Insulation provided and installed by TNT Insulation. Insulation provided rated as R-30. The insulation provided was done in compliance with the applicable sections of the IRC,NYS and Southold Town Building Codes for an existing structure. Result-The insulation installation performed by TNT Insulation, as verified by inspection, is compliant with all applicable codes for an existing structure. The insulation was installed in compliance with the IEC Code for Existing Buildings, in particular Section R503 Alterations. Nicholas J.Mazzaferro,P.E. 5 PSE of EW Y� r- O � �2 Ho p 051 ARop S1010, N. J. MAZZAFERRO, P.E. PO Box 57,Greenport,N.Y. 11944 Phone- 516-457-5596 Consulting Engineer August 4, 2022 Desi�a, Construction, Ii2spection Page 1 of 1 Town of Southold-Building Department 53095 Main Road DD Southold NY 11971 p Re: Residential Alterations 1300 Long Creek Drive A U G - 4 2022 Southold,N.Y. 11971 District-1000, Section-55.,Block-4, Lot-126 BUILDING.DEPT. TOWN OF SO,UTHOLD Building Permit Number—46991 -Alterations Inspection—Rough Plumbing On 8/2/2022, I inspected the construction for the alterations at the noted location. The inspection covered the interior plumbing roughing for the Water Supply System(WS). The inspection results are: 1 —WS—System was exposed, pressurized and readily viewed. I observed the hot and cold water supply lines associated with the alteration. System constructed as required. All construction was done in compliance with the applicable sections of the IRC,NYS and Town of Southold Building Codes. Result—Based upon inspection of this project and to the best of my knowledge,belief and professional judgment,construction as installed complies with the plans and applicable codes of the IRC,NYS and Southold Town Building Codes. Nicholas J.Mazzaferro,P.E. SE of Ey, Y q� O ARoFEssioN�`'� r i JAN 2 a 90.1 BUILDING DEPT. mIAIKI Or enj 1runl n o 1 ' V , 1 f: 44 ,�;^�; !�r�„ •'�ar.�.:"Vit: a { +I F IV PIN do 1 �Ii I i . l� _— i I� 1 • • � � b i A FOUNDIATION(1ST) • i • e i - MANr STATE'ENPRG'Y, COOE' a: o iii � ��.., � - � • �. �„- • B i f➢ X391 @•A • TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 ca oy�o ao� Telephone(631) 765-1802 Fax(631) 765-9502 hgps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: 4_�a OCT 5 2021 Applicatioris and forms must be"'Jill d outin their entirety Incomplete application`s will not be accepted Where 11the Applicant isnot the,owner;an B1J `1015T• Owner's Authoriiatron form(Page 21 shall be completed: TO`- ;. Date:9-28-2021 OW,NEOF R(S) ,PROPERTY Namelisa Finegan _ SCTM#1000-55-4-12 Project Address:1300 Long Creek Drive, Southold Phone#: Email: Mailing Address: 4..CONTACT PERSON Name:Nancy Dwy_er__._._. ._.- Mailing Address: Phone#: Email:dw erdesi ns.inc ahoo.com DE5IGN.PROFESSIONAL-INFORMATION: Name:Nick Mazzaferro Mailing Address: Phone#: Email:nickmazzaferro a outlook.com P._ ______.________._._.___..._ CONTRACTOR1N FORMATION Name:T.B.D. Mailing Address: Phone#: Email: DESCRIPTION,OF.PRO_ SED,.2CONSTRUCTION ❑New Structure ❑Addition Iteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Interior alteration and windows/doors $ Will the lot be re-graded? ❑Yes E14, Will excess fill be removed from premises? ❑Yes []lM 1 P ROPERTY,.IN FORMATION Existing use of property:sin le familyresidence Intended use of property: �ag_..............��w_...r._.�_.._._g��.__._.._....__ same Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to , _ this property? ❑Yes 024 IF YES,PROVIDE A COPY. {heCl("BOX After Reading The owner/contractor/design professional is responsible for all drainage;and storm water issues as provided by Ch'apter'236 of the.Toain Code:,APPLICATION Is'HEREBY MADE to the Building•Department fo`r the"issuance,of a Building Permit"pursuant to the _ di none Ordinance of"the Town of Southold,Suffolk;County,New York and other applicable Laws;Ordinances or Regulations,for the construction of buildings,:" additions,alteratwn$,or,.forremogefor demolition as herein.described.7he"appllcant agrees to comply witFi all applicable laws;ordinances,building de, housing code and regulations and to admit authorized inspectors onpremises`and m"building(s)for;necessary inspections.:False"statements made herein are punishabie�as atiass A'' erimearior:pursuant to'Section 210 45 of the New York State Penal Law Application Submitted (print n me).Lr cy Dwyer 11R'Authorized Agent El Owner Signature of Applicant: r .____�___.________.__._,...___ Date:v g pp �' 2--pu CONNIE D.BUNCH STATE OF NEW YORK) Notary Public,State of New York SS: No.01 BU6185050 COUNTY OF ) Qualified in Suffolk County Commission Expires April 14,2-03 Nancy Dwyer being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this c�� o2 0 day of rte"' l 20—a-1 `V Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) Lisa Finegan residing at 1300 Long Creek Dr. Southold do hereby authorize Nancy Dwyer to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Lisa Finegan Print Owner's Name 2 r: ECCE E BUILDING DEPARTMENT- ElectricaPDpectOPL 1 a 2022 0 ✓�� Gy TOWN OF SOUTHOLD � o Town Hall Annex- 54375 Main Road - PO Bo ^!G DEP% � J��SOUT(-!O(_f� o Southold, New York 11971-0959 'djjo ® Telephone (631) 765-1802 - FAX (631) 765-9502 ✓ ro err southoldtownny.gov — seand(c-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 7/18/2022 Company Name: Peconic Power Sytems Electrician's Name: Robert Stanevich License No.: ME-45056 Elec. email:Peconicpowersys@gmail.com Elec. Phone No: 516-819-7191 '❑I request an email copy of Certificate of Compliance Elec. Address.: PO box 512 Cutchogue NY 11935 JOB SITE INFORMATION (All Information Required) Name: Finnegan Address: 1300 Long Creek Drive Cross Street: Laurel ave Phone No.: Bldg.Permit#: 46991 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Renovation and new underground service Square Footage: 2000 Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In E Final Do you need a Temp Certificate?: YES❑ NO Issued On emaA9.01 —1-a0 '� Temp Information: (All information required) Service SizeFV11 Ph❑3 Ph Size: 200 A # Meters Old Meter# ❑New Service[]Fire Reconnect[]Flood Reconnect❑Service Reconnect E✓ Underground❑Overhead # Underground Laterals ✓ 1 R2 ✓ H Frame Pole Work done on Service? El Y ✓ N Additional Information: Fp- rP, !1111J F� PAYMENT DUE WITH APPLICATION LM JUL 18 2022 , Lam'` BUILDING DEPT. TOW^!OF Sr1l HELD epE 1 BUILDING DEPARTMENT- Electrical S ecto t �p��� �.� � , �� AUL 1 � 2Q�� 410; TOWN OF SOUTHOLD. '. , Town Hall Annex - 54375 Main Road - PO Bo 't �� «O,�_ Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr southoldtownn v.gov a seandasoutholdtownny qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ail Information Required) Date: 7/18/2022 Company Name: Peconic Power Sytems Electrician's Name: Robert Stanevich License No.: ME-45056 `Elec. email:Peconicpowersys@gmail.com Elec. Phone No: 516-819-7191, ❑I request an email copy of Certificate of Compliance Elec. Address.: PO box 512 Cutchogue NY 11935 JOB SITE INFORMATION (All Information Required) Name: Finnegan Address: 1300 Long Creek Drive Cross Street: Laurel ave Phone No.: Bldg.Permit#: 46991 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): .Renovation and new underground service .square Footage: f2obo Circle All That Apply: Is job ready for inspection?: YES NO F Rough In Final Do you need a Temp Certificate?: 0 YES ❑ NO issued On eynaA kd� -I-a®- Temp Information: (All information required) Service Size�1 Ph F]3 Ph Size: 200 A # Meters Old Meter# ❑New Service0 Fire Reconnecto Flood Reconnect[]Service Reconnect❑✓ Underground[-]Overhead # Underground Laterals ✓ 1 2 ✓ H Frame Pole Work done on Service? Y ✓ N Additional Information: n j rC- a PAYMENT DUE WITH APPLICATIONJUL 1 8 20)1 J II . BUILDING DEPT /V � `����� PERMIT# Addr ss: Switches 5-19Outlets I� G FI's S Surface 2 v Sconces H H's UC Lts Fans _ Fridge HW Exhaust 7� Oven. V WAD I Smokes I I y; DW l Mini 1 Carbon Micro I Generator Combo Cooktop Transfer 3 ACAH 1 Hood Service I Amps Have Used Special: �w LAI,, Comments 1��/Qo1 SURVEYED FOR:- 1-4,Q,21/ LOCATED AT � 0 T% � �. •--c �'�J LOT /& e MAP OF �/FN�/Ko,�-r ,G sa�J L d o o SCALE 1'-3a' �'�$•� �jcJ' 3d7 Al C> 'a Q /-,_ offse•s or dimensions shown U S \ n from the structures to the 01� ry lines are for specihcpurpoe. thr•erore are not ur..�to the erection offences.a PoolsPatios,. \a eas,addaion to Bude7 oorgru k,% 4-* s� 4 A/O/�r�4 0` tl lmiS—S-28To7 Scr�jsa/11 � o� AJ.�G•vt / OF NE�� /S4 4•Z- �~ sl � S- to CO 'j GOra^ree<o-ce-ti°ca;•ons indicated he^eo-t shall run only :¢ ,., * to the p--,son for whom the surrey is prepared,and on his behalf to the title company,governmental agency and SURVEYED �� �'j 199/ BY lend ng trs wtior hs.--d he-eon,and to the assignees;of the No.49237 lend-rig institution. Guarantees or cer;ifrcations are not WILLIAM R SIMMONS III ;4J?37 J� rs•e•ab!e to adlitioial ins.a�•o-.s or s..5sea,,ent owners. 7Q WEST MAIN STREET tis�D L SSP traEAST ISLIP, L I. N.Y. cae FILE NO 2�p/'Z. PAGE GRID � rw ewtr RY tr/ L N fINEGAN RE51DENCE PROPOSED A L TfRA TION5 WQnz 6z J W APP OVER AS NOTED < Q DATE: b C) n o m B.P.# FEE:F BY: _- COMPLY WITH ALL CODES OF NOTIFY BUILDING DEPARTMENT AT NEW YORK STATE & TOWN CODES FOLLOWING INSPECTIONS:02 GAM To 4 PM FOR THE AS REQUIRED AND CONDITIONS OF FOLL 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING SOU HEH-b LAN[\IING BOARD 3. INSULATION SOUTH)LBUSTEES 4. FINAL - CONSTRLI'?ION MUST BE COMPLETE FL� C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW !ORK STATE. NOT RESPONSIBLE FOR OCCUPANCY OR -)ESIGN OR CONSTRUCTION ERRORS. USE IS UNLAWFUL WITHOUT CERTIFICA? DETAIN STORM WATER RUNOFF OF OCCUPANCY _ - - PURSUANT TO CHAPTER 236 �j > EXISTING ROOF TO OF THE TOWN CODE, m N REMAIN, ALL AREASI 7r z d _ J O o m o - -- — - - — PLUMBER CERTIFICATION — --- — - --- - -- — ON LEAD CONTENT BEFORELIfMB�NG -- -- — - ALL PLUMBING WASTE _— — --- — --_ _- - - ---- CERTIFICATE OF OCCUPANCY &WATER LINES NEE D SOLDER USED IN WATER TING BEFORE COVERING oC z SUPPLY SYSTEM CANNOT O O O EXCEED 2/10 OF 1% LEAD. Q p oC O - - --- INSPECTION REQUIRED i oL z w _1 - z TW21052 TW21052TW2I052 TW21052 TW210A2 TW21042 11 L I NEW ENTRY DOOR NEW 4" 'V"JOINT EXISTING SIDING TO NEW WINDOWS, ALL w/SIDE LIGHTS VERTICAL CEDAR REMAIN, ALL AREAS LOCATIONS; NEW I x4 SIDING MTH ENTRY AZEK SURROUNDS w/ W u ALCOVE HISTORIC SILL FRONT ELEVATION 5CALE: 4" = I '-0" cz oC - wLn I.L NW Q } 3 a� z G � :1z Uc .Y Lu Lu r , • l� ' h:w.0� .:r: � Iii w•'� . � 414 '�'.:.'F �;. . x v - v' , _qc ' ♦ _ _ _ mit � � +}:. i. �M� V „• , rte,* ^,�,�_ �`'.• " I Y � 4i 4 u a »: d Lu Lm t\ ' OCTmilli 5 77 w .,�.. r . Y. x I ! i k i vr`�y�as t w e a _ m- F • a �w .Y may♦ 1 OF NEw C IkO �� 7k W w tisFo 4'0° 05�o�y PAGE: PESSI ONP� I UNAUTHORIZED ALTERATION OR ADD/TION TO THIS DRAW/NG AND RELATED DOCUMENTS 15 A VIOLATION OF 5EC, 7205 OF THEN Y5, EDUCATION LAW L u = uo ' O 4 N O >, N W Q07Z U' Z J QQ W oCUQ > FW Lf± L N � CX135 CX135 CX135 P3 35 Q STANDING SEAM o �? METAL ROOF ON 4-1 OVERHANG J p z0 II I I I I II 11 TW2032 TW2032 W2032 00 T NEW OUTDOOR LU U W2436 TW2436 NEW BASEMENT SHOWER F VH2GG10 TW2104G TW21046 FW06061 ENTRY o 2868 UL Li Li L cz z Q0 LU Z LU Z BACK ELEVATION SCALE: 4" = I '-0" W � a v W 11- U.J Q } LdIUL LU LL 3 C z ® G � U � z � i Q� Q� TW210410 LTW0410 LU m c QW203 c U F-THW A 81 A 81 Z � U � TW2032 HFL7]H HHEI 7�L-d HLF--]]H W � m W >° L�Lli IC z �- o U = z � Q z SIDE ELEVATION GARAGE SIDE ELEVATION SCALE: 4" = I '-0" SCALE: 4" = I '-0" F Nfk, P y it 9.c PAGE: NO 0570(p ROFES S 101 P, . 2 UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING AND RELATED DOCUMENTS 15 A VIOLATION OFSEC 7203 OF THE N.K5. ,EDUCATION LAW L 7 N O N O >, C13 N d. Q 07 Z DECK (3 - UNDER � Z DEBILCOCK DUCK BOA105 LU QQ J oGUQ � 00 0 0 Li 00 HALL r El 13 o o KITCHEN BEDROOM PANTRY CLOSET CL05U C) L L O � N C Z HALL GARAGE O O l() O O LIVING ROOM BEDROOM _ LOST ENTRY HALL — Z OE O O C) lu 10 C) OL z R EXISTING FI RST FLOOR LAYOUT z z SCALE: l 6" = 1 '-0" HEADER TO BE WRAPPED FINISHED w/ I x AZEK SECTION EXISTING BILCo DECK AS EXISTING 5ECTION G"SHIPLAP C ILING ON A FASTEN EXISTING WOOD B LOCATION DECK HATCH PERMANENTLY TO REMAIN UNDERSIDE O JOISTS; PROVIDE 4" L W VOLTAGE IN PLACE COVER OLD W LED HH WITHI CEILING .22'-10546 —" BILCO LOCATION TION STRUCTURAL MALL 2- 7�1"LVL HEADER MATCH DETAIL BRACKETS -- . — . — . — . - - _ . — . — . — : — . . — @THIS ROOF — . — . WALL BRAC S TO HAVE 4 COVERING - R X 4x4 POSTS ON 10" MIN. 8001b lo'-I Ru — 6'-5/6'-- - — e'-T5(6" la-IC72" 5'-0" 4'-1" SONOTUBE w/POURED TW2032 TW2 32 TW2032 TW2436 TW2436 TW21046 TW21046 _ _ _ Fw060610111 AN FWH2661 CONCRETE FOOTING W U BUILT IN EGRESS nook5 20"x20"x8"d. CL 27'-2Y2" 13'-4" 1'-I I° -s" COMPLETE w/ Ix6 TSG "' BANQUETTE wo ' O HEADER HEADER 4OG DRY CEDAR SCREENING Ln a ��loset ® AREA/ EXISTING BEDROOM ❑ ( �/ _ �' TO BE ALTERED W in WALL LEGEND: WINDOW ALIGN,RONT 4 e CK 121 5q.ft. 5HELr 4 u- KITCHEN W 15.9%L .� ANG ROD m �Vp 8.9%V 'Np _ N } AREAS TO BE REMOVED OUTDOOR EC �D a0 OO ' OF LAUNDRY SHOWER EXISTING STUD FRAME WALLS/PARTITIONS 3-7"0 � OO OO OO EE 0s.D. closet L 0 TO REMAIN AS IS. PATCH ANY SURFACE O _._ — — 4068 U MATERIAL IF AFFECTED BY CONSTRUCTION - - s' O d er hard pipe NEW DOOR 2868 z X x x FRAME IN WALL UNDER NEW CONCRETE N z N z N z v nted to exterior 11 EXISTING DOOR HEADER; LOCATION BA5EMENT 5TAIR Q QL _ — _ 2GG8 0 Q 2-2x8 HEADER NEW CONSTRUCTION: n� PATCH SHEATHING SIDING 2"X 4" STUD FRAME EXTERIOR WALLS FRAMED N MUDROOM m O O O @ I G" OC, UNDER EXISTING WINDOW/DOOR "� ~ •C.C. Z 1-- ENTRY a S.D. 2GG8- UNITS BEING REMOVED; PROVIDE R-15 BATTS, � PROVIDE 20 MINUTE REPLACE EXISTING PLYWOOD SHEATHING ON EXTERIOR, HOUSE WRAP FIRE RATED DOOR WITH SIDING TO MATCH EXISTING;�" GYPSUM BOARD DOWN SELF CLOSING HINGES GARAGE DOORS WITHIN ON INTERIOR SIDE - ALL AREAS PATCHED TO MATCH 14,G' 5'-5" 2068 71 5 0" 14 U DOOR SWEEP UO z EXISTING OPENINGS w 2"X 4" INTERIOR STUD PARTITION, 2- 14" LVL D OPPED HEADER _ 2- 117g" LVL DRPD HD w/ I LAYER�" GYPSUM BOARD ON EACH 71-3-1— T-3" 2'-1^ a m cabinets counter_ •C.O. u 2 '� �- 246 N butler pantry EXISTING GARAGE o SIDE; USE MOISTURE/MOLD RESISTANT GREAT ROOM 03'2Yz" e'-o" Q 1- BOARD IN KITCHEN LAUNDRY�BATH AREAS USE mclos -- 2GG8 ------ N CEMENT BOARD ON ALL AREAS TO RECEIVE TILE 5HELrw/ 11.6" 0 3 A" rr ROD o O S.D. z Q N HALL - • PROVIDE NEW WINDOWS- ANDERSEN 400 SERIES, PREFINISHED WHITE INT/EXT. WINDOWS THROUGHOUT ALL AREAS; EXISTING p A5 EXISTING p LLJ Z r ROUGH OPENINGS � HEADERS TO BE USED EXCEPT WHERE SHOWN. 2668 ® �_ • ANY NEW WINDOW LOCATION TO RECEIVE 2- 2"x I O" HEADERS C I W r ABOVE w/ 2- 2x4 MULLION BETWEEN ANY PAIR. NEW EXTERIOR O �* _ � m DOORS TO HAVE 2- 2"x 10" HEADERS UNLESS OTHERWISE NOTED; x CD x NOTE: MATCH HEADER HEIGHTS TO EXISTING FOR ANY NEW LOCATION. N z - N z_ ° Q + ,OR OVERHEAD � z ENTRY HALL EXISTING BEDROOM z , - G€ PER • NEW INTERIOR TRIMMED OPENINGS AND DOORS TO HAVE P '� RER SPECIFICATIONS 2- 2x8" HEADERS ABOVE. OPENING DIMENSIONS AS NOTED. Ln TO BE ALTERED 3 EXISTING FIREPLACE I xO a I G7 sq.ft, x O IN ACCORDANCE WITH THE TO REMAIN;NEW W i' closet LI F' z 13.4%L RESIDENTIAL ELECTRICAL CODE • PROVIDE R-19 BATT INSULATION WITHIN EXISTING CEILING MA50NRY VENEER 6068 � 7.5%V OF NEW YORK STATE �-- o IF FRAMING CAVITY BECOMES EXPOSED. N 468 U s TO BE 5ELECTED coats i z � - - _ - UP I �sneer - - Q HANG ROD TW21042 TW21042 z 1"41 it " 14'-5" 14 EGRESS TW21052 ' TW21052 TW21052 TW21052 EXISTING MASONRY 7-U 718" ENTRY STOOP 5ECTION SECTION A B PROPOSED FI RST FLOOR LAYOUT Pj lOF NFA, SCALE: ' = 1 '-0° J.M�Z 9 °.p� F� 0 >r PAGE: SOA 0 05709<a ROF�SSIOtAN, 3 UNAUTHORIZED AL TERA TION OR ADDITION TO 77YI5 DR4 WING AND RELATED DOCUMENTS 15 A VIOLA TION OF 5EC 7209 OF THE N.Y.S. EDUCA TION LA W C\1 O C\1 EL u.j _3 u Q (f) C) 00 ........................ 4 F R. F1 11 MASTER DEN 11 1 1 CLOSET L05T II It II it II II II Ll Li CL05ET :g C\1 C) 0 J(s) 0 (n ry z 0 00C) �z EX15TING SECOND FLOOR LAYOUT 9 O5CALE: < r) OL z 0 — E/ Lu �— Lu Z Z SECTION 5FCTION, LU CL Ln 'n t� EXISTING HEADER TO REMAIN UNFINISHED SAVE o/ U) If F0551BLE:CONN LENGTH TO REMAIN CL IT UNFINISHED ATTIC Of EX15TING ROUGH OPENING CONFIRM — Lu tn TO REMAIN P3535 CX 135 CX 135 CX 135 LL- NEW KNEE WALL FRAMED UNDER EX15TING RAFTERS. PROVIDE R-15 EGRESS ALL LEGEND: N o 14--93 INSULATION WITHIN MOISTURE RESISTANT DRYWALL TO BATHROOMAREAS TO 13E REMOVED z EX15TING KNEE WALL5 51DE Of WALL NEW CASEMENT WINDOWS TO HAVE MODIFIED CHECK RAI L 4 G/I COLONIAL GRILL EXISTING STUD FRAME WALL51PARTITION5 TO REMAIN AS 15. PATCH ANY SURFACE Z 5'-6°height at wall a 3'-1 4-2 MATERIAL If AFFECTED BY CONSTRUCTION bench wits 'S pocket u door 0 — - — - — - EXPANDED BATH — - — - — - — - — - — - - - —Ima�oT7—,a ceiling NEW CONSTRUCTION: In 2x4 STUD FRAMING wl R-15 INSULATION, 7-105/," 0 FINISHED TO INTERIOR 51DE AS INDICATED EXISTING VAULTED /P\ U u BY NOTES ON PLAN G-Vo x 2 CEILING TO REMAIN 00 C\j 01 EXISTING EXTERIOR GABLE END z 2"X 4" INTERIOR STUD PARTITION, OAOT ALD 24Q5"' 5'-1 WALL TO REMAIN. BEDROOM TO W/ I LAYER in GYPSUM BOARD ON EACH Lu BE EXTENDED TO WALL; PROVIDE is) EXISTING DEN C.O. 2GG8 EXISTING MASTER (�n- SIDE; USE MOISTURE/MOLD RESISTANT R-15 INSULATION WITHIN FRAMING TO BE ALTERED (n UNFINISHED ATTIC OVER BOARD IN BATHROOM * USE CEMENT in i SHADED AREA DRYWALL TO INTERIOR SIDE. GARAGE TO REMAIN C 0 u 0 SHOWS NEW BOARD ON ALL AREAS TO RECEIVE TILE x n 272 5ei.ft. EX15TING EXTERIOR SHEATHING u EX�05ED CRD55 TIE51 I < CEILING FRAMING 7.57o L 51DING BOTH TO REMAIN TO 13E WRAP ED w/ I x b 7.07o V 0 u u U.J _I N 0 PROVIDE NEW WINDOWS-ANDERSEN 400 SERIES, PREFIN15HED MATERIAL 272 561.ft. '-I: z 03 DOWN 0 1 1 7.8%L 2 POG.8 20G8 WHITE INT/ EXT. WINDOWS THROUGHOUT ALL AREAS; EXISTING ROUGH OPENINGS * HEADERS TO BE USED EXCEPT WHERE SHOWN. 4.2%V EXISTING GABLE END ANY NEW WINDOW LOCATION TO RECEIVE 2- 2xG HEADERS u-j line of 7-O'ce,finq WALL OVER GARAGE-; Z t - — - — - — - — - x PAIR. u q3 L L Z 2411� Co r 45 e.'201G8 �F NEW WINDOW- :tL C105et C105et 2- 2xG HEADER SET AT MATCH HEADER HEIGHTS TO EXISTING FOP,ANY NEW LOCATION.i 5-2" ABOVE GARAGE NLu CLOSET TO 15E CUSTOM WALL PLATE HEIGHT NEW INTERIOR OPENINGS AND INTERIOR DOORS TO 'T 4'-75/8" C105ct BUILT IN WITHIN PITCHED HAVE 2- 2x8" HEADERS ABOVE. OPENING DIMENSIONS AS NOTED. rro o P CEILING LINE.DESIGN DETAILS 4 NEW KNEE WALLS FRAMED UNDER • CON5TRUCTION.,13Y OTHERS • PROVIDE R-38 BATT INSULATION WITHIN EXISTING CEILING WPROVIDE!ATTICEXISTING RAFTERS. PROVIDE R-15 ACCESS PANEL INSULATION WITHIN DRYWALL TO IF ANY FRAMING CAVITY BECOMES EXPOSED. USE R-38 BATT W/ VENTEDBAFFLES IN ANY EXPOSED PITCHED CEILING AREA. o BEDROOM 51DE Of WALL. FRAMING z LEFT EXPOSED ON ATTIC SIDE. UNFINISHED ATTIC TO REMAIN TYPICAL BOTH SIDES Of BUMP OUT. Z —I..OUTLINE Of�FIR57 fLOOP,WALLS BELOW \\:\ f SECTION SECTION SECOND FLOOR LAYOUT OF Ntc-tv 0 MA SCALE: '4,, = J ,-on 70 0 w PAGE: 1pF 0. 0570`b O"Es 51 ON UNAUTHORIZED ALTERATION OR ADDITION TO THIS DPv4 WNG AND RELATED DOCUMENTS 15 A VIOLA T/OV OF 55C 7209 OF THE N Y.S. EDLICA TION LA W L N + O 41 N O >, c z N � Q6Z C9 z lLl � U Q oNo � FIRST FLOOR AREA \ 4x4 POSTS W/2x2 BALUSTERS � CAP RAIL; COMPOSITE RAILING SYSTEM m EXISTING FLOOR STRUCTURE GRADE NEW 2xG ACQ 8" POURED CONCRETE JAMB FRAMING FOUNDATION WALL w/ 2- 2x8 ACID HEADER AT #5 REBAR @ 12"O.C. NEW EXTERIOR DOOR #5 REBAR @ 12" O.C. OUTSIDE (VERTICALLY) ENTRANCE BASEMENT N L #5 REBAR @ 12"O.C. L L 3'-O"X 8" POURED N _ O SECTION � CONCRETE FOOTING q SECTION C ZB O ON COMPACTED FILL J In STAIR WALL DETAIL ° � o � o 4" CONCRETE SLABm o PITCHED TO CENTER FOR SCALE: 4" = I '-O" =1 _ N DRAINAGE PROV. EPDXIED#4 STEEL REBAR HORIZONTAL @ 12" O.G. Z O INTO FOUNDATION W LL ALL AREAS OF ABUTTING WALLS N O_ O WITH FOOTINGS 5TAIR DETAIL Lu \ / < O FIBERGLASS DRYWELL o � p U p W/STEEL REINFORCING; / \ 3068ip O Z PROVIDE 4" P.C. SLAB, up – O PITCHED WITH DRAIN - NEW ENTRY DOOR; O LuWPOUPf DCONCRETE N RELOCATE OIL TANK – FILL LINE TO FRONTN z x Z Z ENTRY STAIRS U Q NZ — CORNER OF BASEMENT z 2 u Q -L+ NUMBER OF TREDS TO p Lu Ln °L z u2� BE VERIFIED IN FIELD BASED E O0 N ON EXISTING GRADE OR 4x4 POSTS W/2x2 t BALUSTERS * CAP RAIL; USE COMPOSITE RAILING SYSTEM C.O. t 5.D. ALL AREAS OF UNFINISHED I I I GARAGE ABOVE n m BASEMENT TO REMAIN UNEXCAVATEDLo Ln oC U-J in Lu 0 II II o I NN 3 Q 4"0 ROOF p' I -Z si- ROOF LJ VENT EXISTING CHIMNEY 4 FOOTING TO REMAIN II I ATTIC 15ATHI Lu - 1I 1 1/2 p1 1/2 i 1 1/2 �1 1/4 1 I SECTION I I A SE B ON � c of o U p I I SH WER ' BASEMENT LAYOUT SECOND FLOOR I I W s 02 2 I SCALE: 4" = 1 '-0" I C.OJ I W C) -- ---T — -r KITCHEN BATH I I BATH IF2 W I I 1 1/2 1 u2 I 3.. 1114 4 11/4 11/4 �11l2 I I 11 114 F.A.I. p z � INK o 0 W. b U o FIRST FLOOR Z 2 11/4 3 2 3 2 11/4 C.oJ _ TO IXISTING SCHD APPROVED 4 SANITARY 5Y5TEM 4"C.I.HOU5E TRAP SLOPE" 1/4" PER FOOT PITCH TO DRAIN OF NFt, BASEMENT q it O 41 0 No 0570 9 `v PAGE: AROFEssIoNP�� 5 UNA UTHORIZED AL TERA TION OR ADDITION TO TH/5 DRAWING AND RELATED DOCUMENT5 15A VIOLA TION OF SEC. 7209 OF THE N.Y.S. ,EDUCA TION LA W 41 0 41 GENERAL NOTES: N 0 • The information on this set:of construction documents is to relate basic design ELECTRICAL NOTES: v z N c "tent and framing details. They are intended as a construction aid, not as a substitute for generally accepted good budding practice and are in compliance with • All electrical work to be BOARD OF FIRE UNDERWRITERS approved and to include Z cf) Q6� current 2020 New York State Building Codes and the 2018 IRC. The general contractor installation of fixtures+�specifications as indicated on plans. Light fixtures to be supplied by Is responsible for providing standard construction details and procedures to ensure a professionally finished, structurally sound and weatherproof completed product. owner and installed by contractor. GPI outlets required at bathrooms and exterior areas. Install all outlets as per code. All work is to be done in strict accordance with the New York State Code • General contractor to cocrdinate all subcontractors, scheduling of work and by a licensed electrician. All new switches*outlets to be Leviton.Toggle, supplied*installed EXISTING ROOF STRUCTURE- Z interaction between trades. w by contractor. Contractor to do all hook-ups as required for bathroom fans, cooking exhausts and RIDGE, RAFTERS, SHEATHING, Q • The contractor is responsible for ensuring that all work and construction meets provide wiring as required for gas fireplace and cooking appliances. ROOFING, INSULATION, DRYWALL or exceeds current federal, state and local codes, ordinances and regulations, etc. ALL TO REMAIN These codes are to be considered as part of the specifications for this building plan. a m FRAMING NOTES' EXISTING CROSS TIES • If in the course of construction, a condition exists which disagrees with that as TC REMAIN; REMOVE indicated on these drawings,the contractor shall stop work and notify the designer DRYWALL SURROUND 4 the engineer immediately. Should he fail to follow this procedure and continue work, • All lumber is to be Douglas Fir#2 or better at I G"on center WRAP FINISH w/ I x TRIM he shall assume all responsibility and liability arising therefrom. • All wood framing In contact with concrete or masonry is to be pressure treated. 'ACQ'designation MATERIAL • Dimensions take precedent over scale-DO NOT SCALE DRAWINGS. refers to current arsenic-free treated wood standards and shall take the place of'CCA' • The designer has not been engaged for construction supervision and assumes no • All TJI's are to be installed in accordance with the manufacturer's specifications and shall include responsibility for construction coordinating with these plans, nor responsibility for squash blocking web stiffeners at bearing points on girders and other load bearing areas _JI construction means, methods, techniques, sequences or procedures or for safety 1_1 and programs in connection with the work indicated. There are no • p p g Structural Steel ASTM A36- FY= 36 KSI 9 DEN warranties for a specific use expressed or implied in the use of these plans. 00 • All straps, connectors, plates, bolts, nails, etc. are to be galvanized. Designated connectors, straps, � EXISTING • Contractor to provide hardwired smoke detectors, with battery back up, and with etc. on these drawings are my by Simpson unless otherwise indicated. All connectors, straps, etc. are to be no Intervening switches, on all floors and in each bedroom. Verify with local code �; KNEE WALLS requirements as per Section R3 17 New York State Residential Construction Code. naileWbolted In accordance with the manufacturers specifications. EXISTING Install carbon monoxide detectors as per code. • All floor sheathing Is to be 4"AC type plywood, tongue 4 groove and shall be glued and screwed to ATTIC the floor Joists(6"o.c. edges# 12"o.c. Heid) FOUNDATION NOT[=S: EXISTING FLOOR STRUCTURE TO REMAIN • Solid blocking is to be installed every 8'-0"max. or mid span of all floor joists with spans exceeding NEW WINDOW LOCATION- j 8'-0". Blocking is to be installed at all point load bearing points. • General contractor to review plans, elevations and details to determine I x4 CASED PROVIDE 2- 2x 10 HEADERS s= intended heights of finished floor above typical grade. • Install double Joists under all partitions running parallel _. OPE '^ REMOVE (1)TOP _ ABOVE C520 STRAPPING • Footings shall bear on undisturbed soil within bearing capacity of 1.5 tons/sq.ft. • All exterior wall headers to be as Indicated on floor plans 4 sections and all interior PLATE; INSTALL NEW 2- 14" LVL HEADER C.—.J N 'L • Concrete shall be FC = 3,500 P51 @ 28 days headers are to be 2-2"x 10"unless otherwise noted. All headers exceeding 5'-0"shall have a double U AT ENLARGED OPENING = }� Jack stud with a single king stud*on exterior walls provide double sill plate(typical). ;r — — BETWEEN LIVING SPACES 3 N • Concrete on 4"sand or gravel fill minimum, with 6x6 - 10/10 welded wire mesh p� reinforcement. Interior slabs to be laced on 6 mil. stabilizedpolyethylene va or • Provide insulation baffles at eave vents between rafters and soffit vents as Indicated fireplace z p P on p , lans GREATROOM barrier. Welded were mesh is to be placed "the top third of the slab and is to be adequately supported by precast concrete bar supports to assure that the reinforcement • Exterior flashingis to be adequately installed at all connections between roofs, walls,is held In position during concrete placement and finishin y PATCH FLOORING s P 9 p g• chimneys, projections and penetrations as required by approved constrction practices. WHERE AFFECTED BY N 0 p 0 • Isolation joints are to be installed between the slab and the walls. Use preformed WALL CONSTRUCTION — ,joint filler that is to be cut 1/2"'below the slab surface and the resulting joint is to be filled FLOOR PLAN NOTES: EXISTING DECK with an elastomeric Joint sealant. • Dimensions shall take precedent over scale drawings, DO NOT SCALE DRAWINGS EXISTING FLOOR STRUCTURE TO REMAIN • General contractor to install cop-r-tex(or copper)sheet metal termite shields between all wood surfaces that are exposed to concrete or masonry surfaces. • All interior walls to be covered with J"gypsum board with metal corner reinforcing. All • Dampproof exterior of foundation wall with a bituminous coating; Foundation drywall products, including gypsum board, screw,joint compound, tapes 4 trim shall be U.S. Z Q excavation upon approval of bUlding department Inspections. Gypsum Co. or approved equal. All Joints shall receive 3 coats of,joint treatment. Said final O O coat to a uniform smooth surface. All walls, ceiling and interior of closets to be taped and C) PLUMBING HVAC NOTES: spackled, 3 coats, ready for paint. BASEMENT TO REMAIN NEW BASEMENT Q~ o� • Interior paint to be Benjamin Moore, walls"WHITE DIAMOND"and ceilings white, unless AS EXISTING ENTRY DOOR W >� • All plumbing work shall be done by a duly licensed plumber and must conform and adhere otherwise decided by homeowner. All Interior trim 4 mouldings to be satin"white diamond'. ° J to all New York State building codes�safety requirements. • Insulation ratings and installation locations as indicated on floor plans*sections. Q C) • If wall plates or joists are cut during the installation of plumbing fixtures or equipment • Interior doors to be solid core wood; style to be determined. Interior trim to be a � Z contractor must provide appropriate bracing to tie franing back together. I x4 casings with, sill and backbands; Metro Collection MC85 12 base moulding. O A E-21 • Plumber to supply and Install tankless, on demand hot water heater. • All bath *kitchen area walls and ceilings adjacent to wet areas to have water resistantW • Plumbing fixtures to be supplied by owner, installed by plumber. drywall, and provide cement board for all areas set to receive tile. Z LLJ _ Z • Mechanical subcontractor Is responsible for adhering to all applicable codes and • Kitchen to have countertops as selected with ceramic tile, subway backsplash; all baths y� safety requirements. to have ceramic tile floors and surrounds as selected by homeowner. • HVAC subcontractor to fully coordinate system data * requirements with the //�� equipment supplier and to pro-vide final system layout drawing and submit it to general contractor, BUILDING S ECT I O N "All owner and equipment supplier for final review*approval. • Mechanical system to be 3 zone with damper controls on second floor. Include SCALE: 4' = I'-O° optional hydrating air system within. • HVAC to vent all dryer*cooking exhausts. TO E 15TING FRAMING 3'-4" NAILING SCHEDULE 2'-0 W u m 201 8 WOOD FRAME CONSTRUCTION MANUAL 12 JOINT DESCRIPTION NAIL QUALITY NAIL SPACINGS —1 t` GENERAL WIND PROTECTION CONNECTION NOTES EXISTING SHEATHING 2x4 ACQ LEDGER BOLTED S�FD ROOF FRAMING Adapted from Standard for Hurricane Resistant Residential Construction; SSTD ROOF TO REMAIN, �� TO HOUSE FRAME; SHED RAFTER TO TOP PLATE TOE NAILED 8'-0"WALL:3-8d PER RAFTER 10-99 and 2018 SBC High Wind Edition Wood Frame Con5tructlon TYPICAL ALL AREAS E�RpF� RAFTERS SIT ON LEDGER � 18-0"WALL:AL:3 8d PER JOIST 2- 7 4 RAFTER 3-8d PEP, Fasteners and Connectors for Wood Frame Construction �X\ �\NG 5� FASTEN w/ H2.5 SERIES LU LVL HEADER, LU CEILING JOIST TO TOP PLATE TOE NAILED o 10'-0"WALL:4-8d PER JOIST I . A continuous load path between footin 5, foundations walls, floors, studs and 2x4 CJ L 16i'w/ WRAP FINISHED p g 6" SHIPLAP CEILING ON 3 CEILING JOIST TO PARALLEL RAFTER FACE NAILED SEE TABLE 3.7 EACH LAP EXISTING DORMER TO F'/ roof framing shall be provided. ST/� UNDERSIDE OF JOISTS STRUCTURAL WALL z CEILING JOLT LAP. OVER PARTI'IONS FACE NAILED SEE TABLE 3.7 EACH LAP REMAIN, INCLUDING COLLAR TIE TO RAFTER FACE NAILED SEE TABLE 3.4 PER TIE FRAME, SHEATHING, G� BRACKET o BLOCKING TO RAFTER Si- TOE NAILED 2-8d EACH END 2. Approved connectors, anchors and other fastening devices not included in �E'T SIDING, INSULATION t 0 WALL BRACKETS TO HAVE U RIM BOARD TO RAFTER END NAILED 2-I Gd EACH END the Standard Building Code, Section 230G of IBC shall be used in accordance DRYWALL INSTALL NEW MIN. BOOB WEIGHT CAPACITY with manufacturer's recommendations. WINDOWS WITHIN �q/ Z WALL FRAMING EXISTING OPENINGS MASTER EXISTING EXTERIOR WALL TOP PLATE TO TOP PLATE FACE NAILED 2-I Gd ' PER FOOT 3. Metal plates, connectors, 5crew5, bolt5, and nails exposed directly to the TOP PLATES AT INTERSECTIONS FACE NAILED 4-1 Gd JOINTS-EACH SIDE weather or Subject to salt corrosion in costal areas, Shall be stainless steel or = BUILT IN STUD TO STUD FACE NAILED 2-1 Gd 24"O/C hot dipped alvarnzed. i i CL05ET TO E(15TING 5UBFLOOR HEADER TO HEADER FACE NAILED I Gd 10'O/C ALONG EDGES pp g EXISTING DECK TOP OR BOTTOM PLATE TO STUD END NAILED 2-I Gd PER 2X4 STUD 4. Where windows and doors interrupt wood structural panel Sheathing and EXISTING 3-I Gd PER 2X6 STUD 5id1n framin anchors or connectors shall be provided at the to and bottom SAVE 4-)Gd PER 2X8 STUD g' g p p BOTTOM PLATE TO FLOOR J015--, of cripple studs, header studs, and at least one stud at each side of opening. EXISTING FLOOR STRUCTURE TO REMAIN BANDJO15T,END JOIST,OR BLOCKING FACE NAILED 2-I Gd ' PER FOOT OVERHANG DETAIL w 5. Ridge straps shall be attached to each pair of opposing rafters except where FLOOR FRAMING collar ties of I xG or 2x4 lumber 15 located in upper third of attic space and NEW WINDOW LOCATION- SCALE: 1" = I '-0" JOIST TO SILL,TOP PLATE,OR GIRDER TOE NAILED 4-8d PER JOIST attach to each pair of rafters. PROVIDE 2- 2x 10 FIEADERS 4 0 BRIDGING TO J015T TOE NAILED 2-86 EACH END G. Uplift connectors shall be provided at each rafter bearing. ABOVE C520 STRAPPING EXISTING FRONT FACADE U BLOCKING TO JOIST TOE NAILED 2-8d EACH END BEDROOM MUDROOM BEDROOM TO REMAIN- FRAMING, BLOCKING TO SILL OR TOP PLAT TOE NAILED 3-I Gd EACH BLOCK 7. Floor to floor hold-downs to be provided every 48, and every I G" within 4' HALL SHEATHING, SIDING, LEDGER STRIP TO BEAM FACE NAILED 3-1 Gd EACH J015T INSULATION 4 DRYWALL; JOIST ON LEDGER TO BEAM TOE NAILED 3-8d PERJ015T i9 PROVIDE NEW WINDOWS BAND JOIST TO JOIST END NAILED 3-1 Gd PER of exterior corners.J015T 2x4 INTERIOR STUD UNDER EXISTING HEADERS LU BAND JOIST TO SILL OR TOP PLATE TOE NAILED 2-I Gd PER FOOT 8. Sill Plate to Foundation Anchorage: Sill plate shall be anchored to the PARTITIONS,1" GYP. Z BOARD foundation with anchor bolts having a min. bolt diameter of 5/8" and 3"x 3"x EXISTING OAK FLOOR EACI1 SIDE �_ CD TO REMAIN; PATCH AS `f ROOF SHEATHING 1/8" washers. A minimum of one anchor bolt shall be provided within G to 12 NEEDED UNDER OLD WALL m 4'PERIMETER EDGE ZONE- I G"C/C-G"AT PANEL EDGES inches of each end of each late. Anchor bolts shall have a minimum embedment STRUCTURAL PANELS 8d AND AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD p LOCATIONS LU of 7 inches m concrete/ masonry foundations. Anchor bolts shall be located m INTERIOR ZONE- 10-O/C-G"AT PANEL EDGES AND 12"AT within 12 inches of corners and at spacing not exceeding 4 feet on center. EXISTING FLOOR STRUCTURE TO REMAIN 8d INTERMEDIATE SUPPORTS IN THE PANEL FIELD Q� • FOR ROOF SHEATHING WITHIN 4'-0"OF THE PERIMETER EDGE OF THE ROOF,INCLUDING 4'-O"ON EACH SIDE OF THE ROOF PEAK,THE 4'-0"PERIMETER W EDGE ZONE ATTACHMENT REQU REMENT5 SHALL BE USED. DE51GN LOAD CALCULATIONS CEILING SHEATHING Q Z } GYPSUM WALLBOARD 5d COOLERS 7"EDGE/ 10"FIELD 75 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS 050 o BASEMENT WALL SHEATHING EXTERIOR BALCONIES 60 AS EX STING O REMAIN Z 53 STRUCTURAL PANELS 112" 1 1 ga.Galy.Roofing nail 3"EDGE/G"FIELD DECKS 40 Q (.1 2"x1.51.x.7/16"head) ATTICS WITHOUT STORAGE 10 25/32" 1 1 ga.Galy.Roofing nail 3"EDGE/G"FIELD ATTICS WITH STORAGE 40 (.l 2'S 1.75"L.x.3/8"head) ROOMS(OTHER THAN SLEEPING ROOMS) 40 FIBERBOARD PANELS 7/1 G" Gd 3"EDGE/G"FIELD SLEEPING ROOMS 30 25/32" 8d 3"EDGE/G"FIELD fl GYPSUM WALLBOARD 5d COOLERS 7"EDGE/ 10"FIELD 4'EDGE ZONE- I G"O/C-G"AT PANEL EDGES AND 1 2"AT HARDBOARD 8d INTERMEDIATE SUPPORTS IN THE PANEL FIELD CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA INTERIOR ZONE- 10 O/C-G"AT PANEL EDGES AND 12"AT 8d INTERMEDIATE SUPPORTS IN THE PANEL FIELD G?.CJ`:D LOAD �5 the S\C'cu' FLOOR SHEATHING 5A8'C 10,1 :J S'_!D 130 mph STRUCTURAL PANELS- I"OR LE55 8d G"EDGE/ 12"FIELD Ex caure C:I`Ccjcry m, PS F Nfly 5_5MIC CA7_GC;Y 5 BUILDING S ECT I O N Nailing requirements are based on wall sheathing nailed G inches O.C.at the panel edge. If wall sheathing is nailed 3 inches O.C.at the panel edge to obtair 1u i n 9� higher shear capaaties,naihng requirements for structural members shall be doubled,or al -?.CST L'.":_D" H 3'-0" SCALE: 4 _ '_?.'t.1 T_ ^ICD_?A-E 70 HEAVY When wall sheathing rs continuocs over connected members,the tabulated number of nails shall be permitted to be reduced to I-I Gd nail per foot, PAGE: N"0' ° 057(P ROFES S 10 6 UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING AND RELATED DOCUMENTS 15 A VIOLATION Of 5EC. 7209 OF THE N.),.S. EDUCATION LAW