HomeMy WebLinkAbout48035-Z 4G0`O c Town of Southold 4/22/2023 a P.O.Box 1179 } 53095 Main Rd o4; a� f}` Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44040 Date: 4/22/2023 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 3485 Rocky Point Rd.,East Marion SCTM#: 473889 Sec/Block/Lot: 21.-6-8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/23/2022 pursuant to which Building Permit No. 48035 dated 7/1/2022 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"rear deck and screened porch additions to existing single family dwelling as applied for. The certificate is issued to Breslin,Deidre of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED Au ori ed i ature ��O g�FFD1��G TOWN OF SOUTHOLD BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48035 Date: 7/1/2022 Permission is hereby granted to: Breslin, Deidre 3485 Rocky Point Rd East Marion, NY 11939 To: Legalize as built rear deck and screen room at existing single family dwelling as applied for. Additional certification may be required. At premises located at: 3485 Rocky Point Rd., East Marion SCTM #473889 Sec/Block/Lot# 21.-6-8 Pursuant to application dated 5/23/2022 and approved by the Building Inspector. To expire on 12/31/2023. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $668.80 CO-ADDITION TO DWELLING $50.00 Total: $718.80 Building Inspector UE SOUIyO TOWN OF SOUTHOLD BUILDING DEPT. couto, 631-765-1802 INSPECT-ION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ rULATIOWCAULKING FRAMING/STRAPPING [ AL Ak-� %j[k- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ . ] RENTAL REMARKS: << Q r DATE �� �Y XIA(/ FIELD INSPECTION REPORT DATE COMMENTS - o FOUNDATION (IST) rQ V" y -------------------------------------- FOUNDATION (2ND) W O ROUGH FRAMING& PLUMBING i r INSULATION PER N.Y. �3 STATE ENERGY CODE '1 FINAL ADDITIONAL COMMENTS - - o zz X t� N >1 b 0 z x E� x e b H tio�sOrut`��o TOWN OF SOUTHOLD —BUILDING DEPARTMENT y z V� Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631)765-1802 Fax (631)765-9502 https://vmw.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only nD PERMIT NO. v S Building Inspector: MAY 2 3 2022 Applications and forms must be filled out in their entirety.Incomplete BUILDING DEPT. applications will not be accepted. Where the Applicant is not the owner,an TOWN OF SOUTHOLD Owner's Authorization form(Page 2)shall be,completed. Date:4.13.2022 OWNER(S)OF PROPERTY: PCTM#.1000-1000-21-06-08 Project Address:3485 Rocky Point Rd. East Marion Phone#: 516 3(0 0-.'. .lD.y-v�_. ... Email: C, ek,c1re o b(eSl-j* -. &N 'I.I -..CM4 MaAddress:,.- ...ilingd :.. _. 19 MS. -- ce. ,... .., . ...11 .40. CONTACT PERSON: Name:Joan Chambers Mailing Address:PO Sc;: 49 Southold NY 11971 Phone#:631-294-4241 Email:joa_nchambers 10@gmailcom DESIGN PROFESSIONAL INFORMATION: Name:Louis Schwartz Mailing Address:? Ridgewood St, Bay Shore, NY 11.706 Phone#:(631) 410-6838 Email:tiderunnereng@gmaii.com CONTRACS"OR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ®New Structure ❑Addition []Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Deck $ Will the,lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 -PROPERTY INFORMATION Existing use of property:�eSICI@r1C „ Intended use of property:Residence,.,.- Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-80 this property? ❑Yes BNo IF YES, PROVIDE A COPY. ❑ Check Boit After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.,APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterationsor for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In_building(s)for necessary inspections.False statements made herein are punishable'as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Joan Chambers BAuthorized Agent ❑Owner Signature of Applicant: Date: 4.13.22 STATE OF NEW YORK) SS: COUNTY OF qhs-55erN ) Joan Chambers being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statenients contained.in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ZACHARY WILLIAM HIEB Notary Public-State of New York J ri ��1 " NO.01H16394299 l day of f7� j�I f ,20 Qualified in Nassau County �- Notary bM Commission Expires Jul 1, 2023 ,,�_�e PROPERTY OWNER AUTHORIZATION ` P� (Where the applicant is not the owner) re 2re SI1 * residing at 199 s (,(,�i LSonl Aide, N Ili 11more- 1 1-'10 do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. rj'-�f- I, 6N&==M !!� 1/ 02 Owner's Signature ate e Irci Cc. 12 Print Owners Name 2 s Concerning: " Breslin Residence . 3485 Rocky Point Rd. East Marion NY 6.27.22 Nancy, Enclosed is the correct survey for 3485 Rocky Point Rd. and I have drawn the location of the deck as you requested, Thank-you, Joan Chambers ' pp}�,,�� .,:.,. ,. ���%(yi,� ne a�py�.�h°'°•""^"ate`__.,..._...-..-' in D LM JUN 2 R 909 BUILDING DERE TOWN OFSOU'7i a'iLB� T Lp OPIW W4 2a' f5 ! LOT 7 1 Y 3$' 940.(V ROCKYa �0R�ROAD [.49.,S , 1 I r Lor10 FuLoTs LNES► SEI C TANKS AND CEMMS SHOWN H TRW M BATA ,:Pr,' �t 0onm • �i1tE�. Gam. � c m�sr ,v��xmrem SURVEVOR LOT a I MEMO= MAP OF EASMARM WOODS Mff MAMX TOWN OF WUMMW mt �7 SURYWIDATE MOM t 3485 ROCKY PT. RD . EAST MARION NY EXISTING: SINGLE FAMILY RESIDENCE SCTM# 1000-21 -6-8 ZONE R-80 PROPOSED: AS-BUILT DECK & AS-BUILT SCREENED ENCLOSURE EXT. WALL OF EXIST, HOUSE C7 EXISTING SLID, GL. DR. Z GENERAL NOTES LLO J 2X12 ACQ LEDGER BDLTED TO HOUSE FRAMING W/ 3/8"x3" EPDXY COATED SCREWS 1. All work shall conform to the requirements of the 2020 Building Code of N.Y. r— — — @ 12' OC STAGGERED Cr ° State, County and Town Department Regulations, Utility Company requirements and LU o I best trade practises. o DN 4 RISERS I I 2. Before commencing work the Contractor shall file all documents required by the o w I I Building Department, pay all fees required by local agencies and obtain all required ° AS-BUILT SCREENED ENCLOSURE w I permits. o = I 3. The Contractor shall visit the site and verify all dimensions and the existing c L— — conditions affecting the work prior to construction. Any discrepancies which would T interfere with the satisfactory completetion of the work described herein shall be o reported to the architect or property owner. Do not start work until such conditions N Q (2) 2x12 GIRDERS STRAFPED TO 4X4 ACQ POSTS - have been examined and a course of action mutually agreed upon. Failure to notify (3) 2X6 HEADER STRAPPED TO 4X4 POSTS TYR. ANCHORED TO 14" DIA. C,)NC. PIERS TO 36" MIN BELOW GRADE the owner or architect of unsatisfactory conditions will be construed as an acceptance 00 of the conditions to properly perform the required work. (o 4. All work is to conform to the drawings and specifications of the architect and Y engineer consultants. LU 5. The Contractor is to maintain a complete and up to date set of plans on the 00 I job site at all times N 6. The drawings are not to be scaled under any circumstances. AS-BUILT DECKS 7. It shall be the Contractor's responsibility to ascertain all prevailing procedures 5/4x4 WOOD DECKING including storage and toilet fa ci I ities,protection of existing work to remain,access to I I work area, hours of permitted work,availability of water and electric power and all other conditions and restrictions for this particular location in order to execute the I work in a careful and orderly manner with the least possible disturbance to the public. 8. The Contractor shall make the neccesary arrangements to utilities and services DECK GUARD RAIL To MEET CODE temporarily disconnected while performing the work as required. 36" MIN. HIGH — — — 4" MIN. SPACE BETWEEN BALUSTERS 9. The Contractor shall provide all dimensions and cut-outs for other trades. — — — — — - - — — — — — — — — — — , r- 10. The Contractor shall provide proper shoring and bracing for all remaining structure W I I prior to removal of existing structure. 1 1 I 11. Plumbing, electrical, HVAC and similar work shall be performed by licensed a persons who shall arrange for and obtain all required inspections.The General o I ( Contractor shall be responsible for scheduling all other inspections as required. L — — —J 12. The Contractor is solely responsible for construction safety and shall hold the 15'-0" owner and architect harmless from litigation arising out of the Contractor's failure to 3'-0" 2'-0" provide construction safety means and methods. 3'-0" 20'-0" '-0" FLOOR PLAN FOUNDATION PLAN CONSTRUCTION NOTES 1 /4" = V-0"011 3 .9 . 2 2 1 /4" = 1 1—W 3 .9 . 2 2 r^" °"'P.! A'^ 1. All footings shall rest on undisturbed soil at a minimum of 3 6" below fin. rade. 4vE"r 6'�i�l+�d��".► ikGT"D 9 9 2. Poured concrete shall have a minimum psi of 3500 at 28 days unless noted. 3. Sill plates shall be preserved, treated wood and be installed above a 16 oz. copper termite sheild. 0 BY: 4. Shingle siding shall conform to ASTM D 3679 and be installed in accordance OCCUPANCYOR NOTHFY BUILDING DEPARTMENT AT with the New York State Building Code and manufacturers specifications. 765-1f;02 0 AM TO 4 P&I FOR THE 6. Unless otherwise noted all framing and structural wood components shall be AS-BUILT SCREENED ENCLOSURE USE IS UNLAWFUL FCJ","I'..�9'�,'i !(7 #2 or better Douglas Fir. ASPHALT/FIBERGLASS SHINGLES h i '�9 - �t VV0 R'EOUIRED 7. All framing techniques and methods shall be as prescriptive design based on ROOFING FELT VOTHOUT CERTIFICATE 1' "...,,�,E';rF'�"'n((;;44�•'`�F= AF&P Wood Frame Construction Manual for One and two Family Dwellings (WFCM) 1/2" PLYWD SHEATHING €�a r¢�Ukl a 2X8 @ 24" OC RAFTERS BOLTED TO f1�1 J� /'t`' {`�` IVIG Or as specified in R301.2.1.1 EXISTING ROOF RAFTERS OFOCCUPANCY .1 .��L1 Ni _Y (, s y�t,rt l )�3 9. Fireblocking shall be provided In all wood framed construction In accordance V V 11 l V V ` 4, FINAL - CONSTRUCTION MUST with NYS Code R 602.8 to form an effective fire barrier between stories and �? COMPLETE FOR C.O. between the top story and roof space. (3) 2x6 HEADER SHALL MEET 11. All portions of the new structure are designed to comply with local geographic ALL CONSTRUCTION and climatic criteria as stated in the following table. 4X4 POSTS @ ENCLOSURE HIE REOUIREMEP'TS OF THE N.Y. n _ TATE CONSTRUCTION! & ENERGY GEOGRAPHIC & CLIMATE DESIGN CRITERIA EXISTING HOUSE AS-BUI1_T DECK GOi�' L j WITH H ALL CODES OF CODES. NOT F?ESPO;+ISIPLE FOR DECK GUARD RAIL To MEET CODE NEW YORK STATE & TOWN CODES On C;OW'il-RUCTION ERRORS GROUND SNOW LOAD 45 psi /// 36" MIN. HIGH WIND SPEED 130 MPH 4" MIN. SPACE BETWEEN BALUSTERS AS REOUIR7 AND CONDITIONS OF SEISMIC DESIGN CATATGORY B 5/4x6 WOOD DECKING 2x8 @ 16" OC DECK JOISTS SOUTHOLDTOVINZBPt WEATHERING SEVERE STRAP JOISTS TO GIRDER FROST LINE DEPTH 2X12 ACQ LEDGER BOLTED ^ t 36" El I TO HOUSE FRAME. SOUTHOLDTOVr1NPMNINGBOPAD l�dditl®nal TERMITE THREAT MODERATE TO HEAVY 2-2X12 ACG DECK GIRDERS ANCHORED CertifiC�tion DECAY SLIGHT TO MODERATE SOUTHOIDTOWNTRUSTEES 11 WINTER DESIGN TEMPERATURE 11 To 10" POUR. CONC. PIERS MIN. BELOW GRADE IY.��.S.DEC Way Be Required. FLOOD HAZARD AS NOTED IJ AS-BUILT DECK & SCREENED ENCL. RETAIN STORM WATER RUNOFF I I I PURSUANT TO CHAPTER 236 3.9.2 2 L_ _J JJ OF THE TOWN CODE" � y ress ,S �f �gQ 0, w 101 r 0-1 ,1� 110� START[" 77006 permits I draffing I ex editin 1 OF 1 SECTION 1 p'��FESSIOPO BOX 49 1 /4" = 11-011 3 .9 . 2 2 JOAN CHAMBERS SOUTHOLD NY 11971 631-294-4241 P-1 V D i BUILDI'MIG DEPT '," ,<a�-Souk;���"