Loading...
HomeMy WebLinkAbout47851-Z OS�FFOt,f�oG� Town of Southold 4/24/2023 t P.O.Box 1179 C4 _ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44051 Date: 4/24/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 610 Lupen Dr., Cutchogue SCTM#: 473889 Sec/Block/Lot: 104.-1-3 Subdivision: Filed Map No. Lot No. i conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/18/2022 pursuant to which Building Permit No. 47851 dated 5/24/2022 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Lufrano,Lucille of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47851 3/10/2023 PLUMBERS CERTIFICATION DATED h iz d Signature TOWN OF SOUTHOLD �o PGS BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE 'd • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 47851 Date: 5/24/2022 Permission is hereby granted to: Lufrano, Lucille PO BOX 642 Point Lookout, NY 11569 To: Install roof mount solar to existing single family dwelling as applied for. At premises located at: 610 Lupen Dr., Cutchogue SCTM #473889 Sec/Block/Lot# 104.4-3 Pursuant to application dated 4/18/2022 and approved by the Building Inspector. To expire on 11/23/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector 0f SOUj�QI . � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(a)-town.southold.ny.us Southold,NY 11971-0959 Q�yCOUNT`I,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Lucille Lufrano Address: 610 Lupen Dr city:Cutchogue st: NY zip: 11935 Building Permit* 47851 Section: 104 Block: 1 Lot: 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: GreenLogic License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency StrobeHeat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 23.3kW Roof Mounted PV Solar Energy System w/ (55) SPR 425W Modules, AC Combiner Panel, 150A Disconnect x2 Notes: Solar Inspector Signature: Date: March 10, 2023 S.Devlin-Cert Electrical Compliance Form pF SOUIyo� --- _ TOWN OF SOU.THOLD BUILDING DEPT. �ycoum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] R GH PLBG. [ ] FOUNDATION 2ND [ NSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL gc/A'✓ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMAR S: 04 WA" VIRAL 40V 44-,0007 DATE 'liv INSPECTOR 47 65 r 41C) Lo ZA�r- pF SOUI # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION ( ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ ] PRE C/O [ ] RENTAL REMARKS: ,epl 415- 14 f /��gf 4 Al"9 kJ c IS 1^41'J9 ed i;glZ,4,Z a DATE INSPECTOR li-� OF SOGTyo� r y 7w - * # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ], FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR OF SOGTyO� # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) >:� pELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE Ca 7i�' INSPECTOR OF SOGTyO� �V� * TOWN OF SOUTHOLD BUILDING DEPT. courmN�' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] . FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS:(Alk R .rp ot P 6, 9T ' /L Lol DATE 116 INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS, J►d OA FOUNDATION(1ST) Cfi y -------------------------------------- FOUNDATION(2ND) 9 � O O S ROUGH FRAMING& PLUMBING y t J W Tj 7 n�G. INSULATION PER N.Y. 6 STATE ENERGY CODE O l riv o ++dl✓ ins FINAL ADDITIONAL COMMENTS S 7,2-- Pay o re-c 101 ans 3 c n N " w � 0 wz Z� d b y 4su�rac � ~<, TOWN OF SOUTHOLD–BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 f. Ip Telephone (631) 765-1802 Fax (631) 765-9502 littps://www.southoldtowzlny.go_v Date Received APPLICATION IL I PERMIT For Office Use Only E PERMIT NO. L Building Inspector: D APP 1 8 2022 BUILDING DEPT. Applications and forms must be filled out in their entirety:Incomplete TOWN OF SOUTHOLD applications Will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date:2/2/2022 OWNER(S)OF PROPERTY: Name:Lucille Lufrano SCTM#100.0-104-1-3 Project Address:610_Lupen Drive,,Cutch,og qq, NY 11935 Phone#:516-697-9455 Email:lenny.lufrano@gmail.com Mailing Address:P.O. Box 642, Point Lookout, NY„1„1569 CONTACT PERSON: Name:Barbara- GreenLogic LLC Mailing Address:97 North Sea Road, Southampton, NY 11968 Phone#:631-771-5152 x117 Email.Barbara�Greenlogic.com DESIGN PROFESSIONAL INFORMATION; Name:James J. Stout Architect & Assoc. Mailing Address:2 Greg Lane, East Northport,, NY Phone#:631-858-9388 Email:stouthub@jamesstoutarch.com CONTRACTOR INFORMATION: Name:Green'Logic LLC Mailing Address:97 North Sea Road, Southampton, NY 11968 Phone#:631-771-5152 —7Email:AlVl@Gree.nlogic.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair EJ Demolition Estimated Cost of Project: EOther ' Solar Panels $, 105,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? Dyes ®No 1 f • PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants nd restrictions with respect to this property? ❑Yes No IF YES, PROVIDE A COPY. 0 Check Box After Reading: The'own er/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building zone Ordinance ofthe Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations'or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and,regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class.A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):GreenLogic LLC DAuthorized Agent ❑Owner Signature of Applicant: Date: 21,2_12 2-- STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Z� day of �Jr�'�I . 20 Notary Public BARBARA A.CASCIOTTA Notary Public, State of New York PROPERTY OWNER AUTHORIZATION No. o�-cA4 Qualified in Suffolkfolk Co Cou ty (Where the applicant is not the owner) Commission Expires May 11, 2 I� Lucille Lufrano residing at d/0 bde �— hereby authorize GreenLogic LLC to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date LJ C- t(2 Ly �rcLt o Print Owner's Name 2 4SUFftJt�,�`r BUILDING DEPARTMENT- Electrical Inspe for 4,o j �j�/ TOWN OF SOUTHOLD o o j Town Hall Annex - 54375 Main Road - PO BoRo 's,, * Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 14 rogerr(aDsoutholdtownnV gov — seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 4/15/2022 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Phone No: 631-771-5152 [El request an email copy of Certificate of Compliance Address.: . 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Lucille Lufrano Address: 610 Lu en Drive, Cutchogue, NY 11935 Cross Street: Phone No.: 516-697-9455 Bldg.Permit#: "j �51 email: lenny.lufrano@gmail.com Tax Map District: 1000 Section: 104 Block: 1 Lot: 3 BRIEF DESCRIPTION OF WOR ectric system - 22-360- - unPower SPR-X22-360- mo em Size: 23.040kW Check All That Apply: � ppY� 'S ,r Is job ready for insp tion?: ❑YES ❑✓ NO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: ❑✓ YES [:]NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1' 02 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx �r,�v✓i�^ °� I sU �l7 Z� , � . 2 AMENDED �SVFFO(�•c�`� BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD H i Town Hall Annex- 54375 Main Road - PO Box 1179 o • �� Southold, New York 11971-0959 yfj0 ao�}Yy Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr ,southoldtownny.gov — seand@southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 3/9/2023 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Phone No: 631-771-5152 gkrequest an email copy of Certificate of Compliance Address.: , 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Lucille Lufrano Address: 610 Lupen Drive, Cutchogue, NY 11935 Cross Street: Phone No.: 516-697-9455 Bldg.Permit#: 47851 email: Lenny.lufranoCgmail.com Tax Map District: 1000 Section: 104 Block: 1 Lot: 3 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (55) SunPower SPR-M425-H-AC panels >:t (55) SunPower SPR-M425-H-AC micro inverters (1) SunPower PV56 monitor System Size: 23.375kW Check All That Apply: Is job ready for inspection?: DYES 0 NO ❑Rough In OFinal Do you need a Temp Certificate?: OYES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground LateralsD1 ❑2 ❑H Frame [—]Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx S.C.D.H.S. REF -04-0096 LOT NUMBERS 'REFER TO "MAP OF SECT1011J ONF. HICKORY ACRES" FILED IN TIYE SUFFOLK,COUNTY '!FRh'.5 OFFICE N ON APRIL 20, 1961 AS FILE NO. 3"325. SURVEY OF PROPERTY I % AT EAST CUTCHOGUE C' W~ TOWN OF SO UTHOLE a o � o 00 00 SUFFOLK COUNTY, N. Y. rte o� 1000-104-01-03 O SCALE: 1'=30' Q m z (VACANT) FEBRUARY 26, 2004 OCTOBER 5. 2004 -- NOVEMBER 23, 2004 (FOI,Nf-A ri!)N It, - (DgWNG UNKNO„'N NOVEMBER 9, 2005 (TINA!1 ro WELL G.P. LDC. •, -:, DRI VE �� j 130.00' �..._ ` WATER Ng0'12'50 1 . '8 v •;t ." 'j .tel CIEC ,G p7`SECOND O rr FLA �o S c f 1 p aE Z ` ANw 23.4 f-LP 17.6 \ '� 5EG � ON Nf.A �xx o"p g E 57DR RAGE 7 x_x�x -A HOUSE fa. r y for 6 N K m x a SHo.YiFA \ > >• q 1 � X UMOEAGPU TANK 1 J EXISTING WELL FOR NON-POTABLE USE ONLY. PAGPANE -c.E. "p G�S�vclION 00X ENCS °�� '� ��1�E 16' I am familiar with the STANDARDS FOR APPROVAL S.T. 20.9 a AND' CONSTRUCTION OF SUBSURFACE SEWAGE C. AOT o u DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES Ne s. ,� Eby%"/ O and will abide by the conditions set forth therein and on the (.�1 e1•2' t'' Qa SioG'`K permit to construct. �J 1 G.P. m 26P The location of wells and cesspools shown hereon ore . LP ~ 41.Y from field observations and or from data obtained from others. Slot' WALL/y% N� t;G) j(00 M Elevations are referenced to an assumed datum. 1 X/�/S6�'1�50 tGGG OF Ne ANY ALTERATION OR ADDITION TO THIS SURVEY IS A WOLAAON OF SECT/ON 7209 OF THE NEW YORK STATE EDUCATION LAW. G'�E d bZ^QN ov • � �` N EXCEPT AS PER SECTION 7209-SUBD/NSION 2. ALL CER),FICAnONS �i ,.j6'iQ W 5081 HEREON ARE VALID FOR THfS MAP AND COPIES THEREOF ONLY IF $i7 PECONiC VEN SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR 63.37' .3.3,71 ,3S Ft11`J (631) 765 WHOSE SIGNATURE APPEARS HEREON. NG) i7�St�QJ�$� P.0. BOX - AREA=22,635 SQ. FT. =_MONUMENT (CD ��G, UNKNOW `'��f 3;)7;j 1-130 rRAt . K� ,.lIIHlclli', . '� 11=f LOGIC° ENERGY April 15,2022 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Lucille Lufrano 610 Lupen Drive Cutchogue, NY 1000-104-1-3 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, M,dam W 4kMfa, Barbara Casciotta Account Manager GREEN95)&kaVAX9v0PAK-fflRom Tel: 631.771.5152 Fax: 631.771.5156 X31 771 5152 ext. 117 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd., #106 Southampton, NY 11968 Rosyln Heights, NY 11577 REENLOGICO ENERGY D L (�, �I IUI !� � March 9, 2023 � r MAR 13 2023 SOLOING OEPT Town of Southold TOWNOFSODli-IOLO Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Lucille Lufrano 610 Lupen Drive Cutchogue, NY 1000-104-1-3 Permit:_47851 Dear Building Inspector: Enclosed please find the below revised documents as the system changed. • Amended Electrical Inspection • 2 Amended Plansets • 2 Electrical Drawings • 2 Spec. sheets of the solar panels Please let us know if you need anything else in connection with this application. Yours truly, Jia&wiac C'amciottac Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 ext. 117 GREENLOGIC LLC • www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd., #106 Southampton, NY 11968 Rosyln Heights, NY 11577 DATE(MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 02/01r2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Nicholas Zulkofske Brookhaven Agency,Inc. ' PHONE 631 941-4113 FAX 631 941-4405 100 Oakland Ave,Ste 1 E-MAIL DRESS, Certificates@ brookhavena enc .com Port Jefferson,NY 11777 INSURERS AFFORDING COVERAGE NAIC# INSURER A.Southwest Marine&General Insurance Co. INSURED INSURER B•Merchants Preferred Insurance Co. GreenLogic,LLC s INSURER c:First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER D: National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E: AGCS Marine Insurance Co. INSURERF: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTRX COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE S1.000.00 A CLAIMS-MADE ®OCCUR DAMAGI OR(Fe occurrence) E TO RENTED $100,000 X Contractual Liability X X GL202200012922 01/31/2022 01/3112023 MED EXP(Any oneperson) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY�)ECT 71 LOC PRODUCTS-COMP/OP AGG $2,0009000 OTHER: E&O Liability $1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1 OOO OOO B X ANY AUTO - BODILY INJURY(Per person) $ OWNED SCHEDULED X X CAP1043565 08M112021 08M1/2022 BODILYINJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ X AUTOS ONLY X AUTOS ONLY $ UMBRELLA LIAB H OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE) $ DED RETENTION $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY ANY PROPRIETORIPARTNERIEXECUTIVE Y/N E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A see separate certificate (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ C NYS Disability D251202 04/11/2021 04/1112022 Statutory Limits E Installation Floater/Property SML93076366 04/1512021 04/1512022 $300,000 $2,500 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may he attached if more space is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD vlEw Workers! CERTIFICATE OF SYAYE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Greenlogic LLC 631-771-5152 97 North Sea Rd.,Suite 3 1 c.NYS Unemployment Insurance Employer Registration.Number of South Hampton,NY 11968 Insured Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identscation Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Porrcy) Number 203801194• 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) United Wisconsin Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"1 a" Building Department 53095 Route 25 WC589-00169-021-SZ Southold,NY 11971 3c.Policy effective period 12/01/2021 to 12/01/2022 3d.The Proprietor,Partners or Executive Officers are included.(Only check box it all partners/officers included) all excluded or certain partnerstofficers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"9 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2'. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate.is valid for one year after this form is approved by the insurance carrier or its licensed.agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,noir does.it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,If the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Alicia Christiansen (13-nt name of authorized representative or licensed agent of insurance carrier) Approved by: 1 2, 2 (Signature) (Date Title: Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier: 941-306-3077 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NO authorized to issue it. C-105.2(9-17) www.wcb.ny.gov NEW Workers' CERTIFICATE OF INSURANCE COVERAGE sTAZ E Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that Carrie 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured GREENLOGIC,LLC 631-941-4113 97 NORTH SEA ROAD,SUITE 3 SOUTHAMPTON,NY 11968 1 c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD BUILDING DEPARTMENT 3b.Policy Number of Entity Listed in Box"1 a" 53095 ROUTE 25 DBL251202 SOUTHOLD, NY 11971 3c.Policy effective period 04/11/2021 to 04/10/2023 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 4/7/2022 gY w��!,lY�U� 9 (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200, Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4B,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12_21) IIIIIIIP1°��°1��2�0°��1�����l�121°11°1°�'lllllll .K A,77-`t 61� M 4'.... V g Suffolk County Executive' Office of Consumer Affairs s VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 DATE I9SUED: 5/25/2006 No. 40227-H SUFFOLK COUNTY Home Improvement Contractor License This is to certifv that MARC A CLEAN doing business as GREEN LOGIC LLC having ftu-nished the requirements set forth i n accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York is hereby licensed to conduct business as a HOME IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Businesses A0 X. NOT VALED WMIOUT D)EPARTMENTAL SEAL AND A CURRENT k". CONSU1%AER AFFAIRS ID CARD v- IM. Director MRI . -A 4, '71 & W` X, A� A, 12" 1K A Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 DATE ISSUED: 12/10/2007 No. 43858-ME SUFFOLK COUNTY .Master Electrician License This is to certify that ROBERT J SKYPALA doing business as GREENLOGIC LLC having given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance f with and subject to the provisions of applicable laws,rules and regulations of i the County of Suffolk, State of New York. Additional Businesses NOT VALID WITHOUT DEPARTMENTAL SEAL ANDA CURRENT CONSUMER AFFAIRS UP CARD � a Director -_J I® J A M E S J. S TOUT A R C H I T E C T gC Assoc. 2 GREG LANE E AST NORTHP0RTN. Y. 831 - 8 58 9388 Letter of Certification April 7, 2022 RE: Lufrano Residence 610 Lupen Drive Cutchogue, NY 11935 To whom it may concern: I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above- mentioned address and have determined the structure and the attachment to be adequate to support the new additional load imposed by the proposed solar system and complies with the 140-mph wind design load as per 2020 Residential code of NYS(RCNYS), 2020 building code of NYS(BCNYS) residential code, 2020 Energy conservation construction code of NYS(ECCCNYS)and the 2017 National Electric Code NFPA 7012017 National Electric Code, and the ASCE 7-16. The existing 2"x 10"@ 16"o.c. roof rafters will provide adequate support. James J.Stout Architect ?,IEDARC, S J S?-0 T0 � - Yrs 021 �0 `� OF NE`N G ENL®GIC® ENERGY GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#A: Total System Size:23.375 Array Size:16.150M 1 circuit of 10 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuitof9 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:156° Pitch:35" Monitoring System: N SunPower Pand/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:48'2 1/8"X 18'6 5/8" Surface:49'7"X 22'6" Magic*.Invisimount Legend: ® 38 SunPower 425W Panels SunPower Invisimount Rail f 60 UniRac Drk Standoff B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: .ED ARC s roe .9 21633 �0 OF NE`N Drawn By:MA Drawing#1 of 8 Date:5/23/2022 REV:A Drawing Scale:1/8"=1.0' V a GREENLOGICO sl ENERGY GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#A: Total System Size:23.375 Array Size:16.150kW 1 circuit of 10 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuitof 9 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:156° Pitch:35" Monitoring System: SunPower Pand/Array Specifications: Panel:SPR-M425-H-AC Raddng:SunPowerinvisimount Panel:73.7"X 40.6" Array:48'2 1/8"X 18'6 5/8" Surface:4917"X 22'6" Magic#:Invisimount Legend: ® 38 SunPower 425W Panels SunPower Invisimount Rail • 60 UniRac Drk Standoff 18 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" JAITI Materials Used:UniRac,SunPower Added Roof load of PV System:2.31psf Engineer/Architect Seal: �,,�RED ARC �5 SES J STC 'ttil �' s J 1633 °`� F NO Drawn By:MA Drawing#2 of 8 Date:5/23/2022 REV:A Drawing Scale:1/8"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#A• Total System Size:23.375 Array Size:16.150kW 1 circuit of 10 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:156° Pitch:35° Monitoring System: SunPower Panel/Arra Specifications: Panel:SPR-M425-H-AC Raddng:SunPower Invisimount Panel:73.7"X 40.6" 1 2 Array:48'21/8"X 18'6 5/8" Surface:49 7"X 22'6" Magic#:Invisimount Legend: ® 38 SunPower 425W Panels 1 3 — SunPower Invisimount Rail • 60 UniRac Drk Standoff 8 2x10"Douglas Fir Rafter 16"O.C. Notes: 1 4 Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: DARc� S J S TOG �T�O P T ` 6 sr 02 33 y0Q' OF NE`N Drawn By:MA swing#3 of 8 Date:5/23/2022 1 REV:A Drawing Scale:1/8"=1.0' ;�, GREENL®GIC° ENERGY GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#B: Total System Size:22.950kW Array Size:7.225kW 1 circuit of 7 on a 20A breaker 1 circuit of 10 on a 20A breaker ❑ Aam156° o Pitch::35 35° Monitoring System: N SunPower Pand/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:27'6"X 18'6 5/8 Surface:34'1"X 22'2" Magic IP invisimount Legend: ® 17 SunPower 425W Panels SunPower lnvisimount Rail • 30 UniRac Drk Standoff H 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: QED Ai?e 0• g33 SOC" • � F NE`N Drawn By:MA Drawing#4 of 8 Date:5/23/2022 REV.A Drawing Scale:3/16"=1.0' U�GREENLOGIC@ ENERGY GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#B- Total System Size:22.950kW Array Size:7.225kW 1 circuit of 7 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:156° Pitch:35" Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-M425-H-AC Racidng:SunPower InI M visimount Panel:73.7"X 40.6" Array:2T 6"X 18'6 5/8 Surface:34'1"X 22'2" Magic Invisimount Legend: ® 17 SunPower 425W Panels SunPower Invisimount Rail • 30 UniRac Drk Standoff Op 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower - ------f.�, Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ED At?c \5 PEES J S TOS IIx s i k:Y `sg J �.i tira,.o 0 1633 y0 N E� Drawn By:MA 1-UraVing#5 of 8 Date:5/23/2022 REV:A Drawing Scale:3/16"=1.0' G�� EL®GIC® ENERGY GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#B• Total System Size:22.950kW Array Size:7.225WV 1 circuit of 7 on a 20A breaker 1 circuit of 10 on a 20A breaker ❑ Azimuth:156° c Pitch:35° Mel Z Monitoring.System: SunPower 0 5 Pand/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount 77V Panel:73.7"X 40.6" Array:27'6"X 18'6 5/8 Surface:34'1"X 22'2" -Z Ma is#:Invisimount Legend: 6 ® 17 SunPower 425W Panels SunPower Invisimount Rail • 30 UniRac Drk Standoff 2x10"Douglas Fir Rafter 16"O.C. /E X Z Notes: Number of Roof Layers:1 6y\ Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf I/ T T Engineer/Architect Seal: �5 s J s roe 33 �Q- F F N E\N Drawn By:MA Drawing#6 of 8 Date:5/23/2022 REV.A Drawing Scale:3/16"=1.0' No Vent Pipes Will Be Covered By The Solar Array GREENLOGIC° ENERGY Legend: GreenLogic,LLC Approved Lufrano,Leonard AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge 610 Lupen Drive per R202 definitions per R324.6.1 as per R324.6.2.1 Cutchogue,NY 11935 Total System Size:23.375 1 circuit of 10 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuitof9 on a 20A breaker 1 circuit of 10 on a 20A breaker 1 circuit of on a broker 1 2D 1 circuit of 10 on a 20A breaker Meter Azimuth:156° Monitoring System: SunPower 01 Pand/Array Specifications: Panel:SPR-M425-H-AC Raddng:SunPower Invisimount Panel:73.7"X 40.6" Surface:83'8"X 45' Magic*Invisimount Legend: 1 I ® 55 SunPower 425W Panels I I — SunPower Invisimount Rail I I • 90 UniRac Drk Standoff I I 18 2x10"Douglas Fir Rafter 16"O.C. API IAP 1 I I I Notes: I I Number of Roof Layers:1 1 I Height above Roof Surface:4" L---------------------I _________ ______ Materials Used:UniRac,SunPower __—_——_————gyQ-____ —flRVO Added Roof load of PV System:2.31psf I En ineer/Architect Seal: IAP IN ig Mf \V tED ARc �5 �SiST �T 38 SunPower 17 SunPower �4 425W Panels 425W Panels �� , 21633 �0 OF NE`s Drawn By:MA Drawing#7 f:1 Date:5/23/2022 REV:A Drawing Scale:1/16"=1.0' /\ GREENLOGICO ENERGY GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive NY 11935 JOB MATERIAL LIST Cutogue, i Total System Size:23.375 1 circuit of 10 on a ZOA breaker 1 circuit of 9 on a 20A breaker tcircu0of9 on a 20A breaker -_- --- - - - 1 circuit of 10 on a 20A breaker 1 circuitof 7 on a ZOA breaker 1 circuit of 10 on a 20A breaker _. Azimuth:156° Material List QtV. Rail Material List t �V Monitoring System: SunPower Pandl/Army Specifications: �_... .... _. ... _ Panel:SPR-M425-H-AC _- ------- ----- UniRac 4 Drk Standoffs 90 -- ---- --- -- --- ---�---•-, Radang.SunPower In ' 'wslmount 5/16"x4.5"55 lag Bolts 180 Panel:73.7"X 40.6" f.....__.__._ --•_---.._--. - Surface:83'8"X 45' 5/16r Stainless Steel Washers 180 _ Magic#•Invisimount Oatey 11920 Flashing(Silver) 32 Oatey 12920 Flashing(Black) 58 ® 55 SunPower 425W Panels -- ii SunPower Invisimount Ra • 90 UniRac Drk Standoff 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: -,ED ARCM T� i U1, IT 0 633 �0 Z CP NES Drawn By:MA 1-M=ing#8 of 8 Date:5/23/2022 REV:A Drawing Scale:1/16"=1.0' SUNPOWERG 400-425 W Residential AC Module SunPower°Maxeon°Technology Built specifically for use with the SunPower EquinoxT°°system,the only fully integrated solution designed,engineered and warranted by one manufacturer. �® Highest'Power Density Available. SunPower's new Maxeon®Gen 5 cell is 65%larger than H prior generations,delivering the most powerful cell and highest-efficiency panel in residential solar.The result is more power per square meter than any commercially available solar. X • % larger 5" 6" Fundamentally Different. ff f And Better. MR1, 1,... Highest Lifetime Energy and Savings. Designed to deliver 60%more energy over 25 years in real-world conditions like partial shade and high temperatures.' SunPower®Maxeon®Technology 15096 C--------_ ------------------------- • Most powerful cell in home solar 2 140% ------------ a • Delivers unmatched reliability a 13096 120% Up to SunPower" • Patented solid metal foundation prevents 11096 eries 60% breakage and corrosion 100% more 90% lifetime 80% energy T70% �Efl N 6096 0 5 10 15 20 25 7 Years of operation Best Reliability. Best Warranty. ® With more than 25 million modules deployed around Factory-integrated Microinverter(MI) the world,SunPower technology is proven to last.That's '• • Highest-power integrated AC module why we stand behind our module and microinverter in solar with the industrys best 25-year Combined Power and — • 60%lighter than prior SunPower MIs . Product Warranty,including the highest Power Warranty • Engineered and calibrated by SunPower for SunPower AC modules in solar. A-Series:A425 I A415 A400 SunPower®Residential AC Module ,AC Electrical Data Inverter Model:SPWR-A4 @240 VAC Peak Output Power 366 VA Max.Continuous Output Power 349 VA Nom.(L-L)Voltage/Rangez(V) 240/211-264 Max.Continuous Output Current(A) 1.45 Max.Units per 20 A(L-L)Branch Circuit3 11 CEC Weighted Efficiency 97.0% Nom.Frequency 60 Hz Extended Frequency Range 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 5.8 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor(adjustable) 0.7 lead./ 0.7 lag. DC Power Data Warranties,CertifIcations,and Complianc;e SPR-A425-G-AC SPR-A415-G-AC SPR-A400-G-AC 25-year limited power warranty Nom.Power 5(Pnom) 425 W 415W 400 W Warranties 25-year limited product warranty PowerTol. +5/-0% +5/-0% +5/-0% UL 1703 Module Efficient 22.8 22.3 21.5 Certifications UL 1741/IEEE-1547 and Efficiency UL 1741 AC Module(Type 2 fire rated) Temp.Coef.(Power) -0.29%/°C Compliance UL 62109-1/IEC 62109-2 Shade Tol. Integrated module-level max.power point tracking FCC Part 15 Class B ICES-0003 Class B CAN/CSA-C22.2 NO.107.1-01 OperatingTested • • CA Rule 21(UL 1741 SA)^ Operating Temp. -40°F to+140°F(-40°C to+60°C) (includes Volt/Var and Reactive Power Priority) UL Listed PV Rapid Shutdown Equipment6 Max.Ambient Temp. 122°F(50°C) 3000 Pa,305 kg/M2 front&back Enables installation in accordance with: Wind:62 psf, Max.Load •NEC 690.6(AC module) Snow:125 psf,6000 Pa,611 kg/M2 front •NEC 690.12 Rapid Shutdown(inside and outside the array) Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) NEC 690.15 AC Connectors,690.33(A)-(E)(1) Mechaaical Data When used with InvisiMount racking and InvisjMount accessories (U L 2703): Solar Cells 66 Monocrystalline Maxeon Gen 5 Module grounding and bonding through InvisiMount Front Glass High-transmission tempered glass with Class Afire rated anti-reflective coating When used with AC module Q Cables and accessories(UL 6703 and Environmental Rating Outdoor rated UL 2238)6: Rated for load break disconnect Frame Class 1 black anodized(highest AAMA rating) PID Test Potential-induced degradation free Weight 46.5 lbs(21.1 kg) Recommended Max. 1.3 in.(33 mm) I--72.2(1835) ^{ Module spacing _I I 1 SunPower 415 W,22.2°h efficient,compared to a Conventional Panel on same-sized 1. I � j (57140 arrays(260 W,16%efficient,approx.1.6 m'),7.9%more energy per watt(based on PVSyst pan files for avg.US climate),0.5%/yr slower degradation rate(Jordan,et.al. L "Robust PV Degradation Methodology and Application:'PVSC 2018). o I 2 Based on search of clatasheet values from websites oftop 10 manufacturers per IHS,as of c ❑ in.(mm) 1.2(30) r__ January2019. g 3#1 rank in"Fraunhofer PV Durability Initiative for Solar Modules:Part3."PVTech Power i7 -�-(- Magazine,2015.Campeau,Z.etal."SunPowerModuleDegradation Rate;'SunPowerwhite J paper,2013. 4 Factory setto 1547a-2014 default settings.CA Rule 21 default settings profile set during , 1.57(40) commissioning. 5 Standard Test Conditions(1000 W/m'irradiance,AM 1.5,25°C).NREL calibration standard: SOMS current,LACCS FF and voltage.All DC voltage is fully contained within the module. -)- 6 This product is UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; --4.87(22)!­-- and 0.87(22)!­-- and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors; when installed according to manufacturer's instructions. See www.sunpower.com/facts for more reference information. ACM- For CMOtt&EFor more details,see extended datasheet www.sunpower.com/datasheets Specifications RMACTNE included inthis datasheetare subjecttochangewithoutnotice. wwvosnnooa. I ' U ©2019 Sun Power Corporation.All Rights Reserved.SUNPOWER,theSUNPOWER logo and LISTED to 0 S V N P C��/V E R MAXEON are registered trademarks of SunPower Corporation in the U.S.and other Module F(re Fedorma=Type 2 countries as well.1-800-SUNPOWER. Please read the Safety and Installation Instructions 532628 for additional details. 532618 RevA NEW EQUIPMENT PV--SA-1 EMSTING SERVICE AC-COMIBINER PANEL I 1120/240, '!PH, 3W AC-CMB-1 (PV LOADS ONLY) 11 w i PV-[SA-2 N PV-SA-3 BKR-1 AC-DSC-1 AC DISCONNECT 1 Ll 'Jr BKR-2 PV-SA-4- L L ; 3" FM rm --77 BKR-3 BKR-4 MAIN PV-S4-5 BK A B IJ r-lF'UJSEDf PV-SA--a BKR-r) 1 F- 13KR-7 EG N PV-SA-71 A- I ! I N EGC EXISTING AC P,44DEXISTING GEC EC 23-.040kW DC 20.160M AC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Lufrano, Leon.ard MF JM 610 Lupen Drive a w1pGREENLOGIC0 Cutchogue, NY 11935 lko ENERGY ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No Lufrano-3LD1 Revision: 1 Revised: 2/2/22 m' EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V,200A, NEMA-1, 1-PH,3-WIRE BKR-1 CIRCUIT BREAKER,PV-SA-1 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-5 CIRCUIT BREAKER, PV-SA-5 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-6 CIRCUIT BREAKER, PV-SA-6 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-7 CIRCUIT BREAKER,PV-SA-7 MATCH AC COMBINER PANEL BRAND,2-POLE,20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 100A, NEMA-1, FUSED; FUSE RATING:100A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4"PVC-40 12 / 6 B THWN-2 2"PVC-40 4 / 6 C THWN-2 2"EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE,DISTANCE,AND DERATING FACTORS. 2.)ELECTRICAL CONDUIT TO BE MIN.PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Lufrano, Leonard GREED'E D' O 610 Lupen Drive ��'��:�;'�� A �'� � � Cutcho ue, NY 11935 �i�LS�CY g ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Lufrano-3LD1 Revision: 1 Revised: 2/2/22 GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#A: Total System Size:23.040WArray SIza 17.640kW - I cYailt of 11 on a 20A breaker 1 cimit of 10 on a 20A breaker 1 cto,it of 9 on a 20A breaker 1 Ckooltof 10 on a 20A breaker 1 ckcuit of 9 on a 20A bre akar Azimuth:156° Pitch:35" Monitoring System: SunPower PanellArra S cificatlons: Panel:SPR-X22-360•E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:48'10 114"X 20'7 314" Surface:49'T'X 22'6" Ma is#.Invisimount 0 Legend: Q 49 SunPower 360W Panels SunPowerinvisimount Rail • 82 UniRac Drk Standoff B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" i Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: I. Fo R .Nlb' -S JSE 01 ro y�T k t'�� i RPP tt�� ; y' l H BUILDING DEPS: ,� X21 33 `0 Q01�' OF SOt1Ti'1..-LI-' F r t�E�U Drawn By: DD g#1 of 8 Date:4/7/2022 REV:A Drawing Scale:1/8"=1.0' LOGIC@ r Gree»Logi'c,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#A: Total System She:23.040kW Array Sze:17.640M 1'ctcult of 11 on a 20A brealmr 1 circuit of 10 on a 20A breaker 1circuit of 9 on a 20A breaker 1 circuitof 10 on a 20A breaker 1 circuit of 9 on a 20A bre akar Azimuth:156° Pitch:35" Monitoring System: N SunPower Pand/Anray Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:48'10 114"X 20'7 314" Surface:49 7"X 22'6" Ma is#:Invisimount Legend: 0 -r 49 SunPower 360W Panels SunPower Invisimount Rail • 82 UniRac Drk Standoff 99 2x10"Douglas Fir Rafter 16"O.C. 11/114\11 IT \/ Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: D AFS, \G .Es J s ON tt �y,`,Y'�srp�l•�K L1 .1 4fi lr s .a 0 N Drawn y:M4 Drawing#2 of 8 Date:4M20212 I REV:A Drawing Scale:1/8"=1.0' LOG 6C° GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#A: Total system she:23.040kw Array Sze:17.540M Ick 10M of 11 on a 20A hie afar 1 Ckalt of 10 on a 20A bre eker t crait of flon a 20A breakar 1 Omit of 10 on a 20A bresker 1 omit of 9 on a 20A hrasker Azimuth:156" Pitch:35" Monitoring System: N SunPower PanellArra S cificatlons: Panel:SPR-X22-360-E-AC 1 3 Ranting:SunPowerinvisimount Panel:61.39"X 41.18" Array:48'10 1/4"X 20'7 3/4" Surface:49 7"'X 22'6" Magic#.Invisimount 1 1 0 2 4 Legend: t-_t. 49 SunPower 360W Panels SunPower Invisimount Rail 1 2 5 4 • 82 UniRac Drk Standoff 10 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 1 2 S Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: • GJ i i S]• '� /T,< O NE`N Drawn Drawing#3 of 8 Date:4/7/2022 'REV:A Drawing Scale:1/8"=1.0' GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#B: Total System Size:23.040kW Array Size:5.400kW 1 circuit of 7 on a 20A breaker 1 circuit of 8 on a 20A breaker ❑ Azimuth:156° o Pitch:35° Monitoring System: SunPower 0 Panel/Affay Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 3/4'X 15'5 5/8" Surface:34'1"X 22'2" Ma is#:Invisimount Legend: 15 SunPower 360W Panels SunPower Invisimount Rail • 28 UniRac Drk Standoff 0� 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seat: 6 � F N E\N Drawn By:MA Drawing#4 of 8 Date:4/7/2022 REV:A Drawing Scale:3/16"=1.0' LOGIC° GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#B: Total System Size:23.040kW Array Size:5.400kW 1 circuit of 7 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:156° Pitch:35° Monitoring System: SunPower Pan el/Array Specifications: Panel:SPR-X22-360 E-AC Racking:SunPower Invisimount �• Panel:61.39"X 41.18" Array:Z4'4 3/4"X 15'5 5/8" Surface:34'1"X 22'2" n 11 Magic#.Invisimount L end: -�.. 15 SunPower 36OW Panels i. — SunPower Invisimount Rail • 28 UniRac Drk Standoff B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf Engineer/Arc hitect Seal: �lti 9l 02 6�N O NO • Drawn By:MA Drawing#5 of 8 Date:4/7/2022 REV.A Drawing Scale:3/16"=1.0' LOOIC� GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive i Cutchogue,NY 11935 Surface#B: Total System Size:23.040kW Array Size:5.400kW 1 circuit of 7 on a 20A breaker 1 circuit of 8 on a 20A breaker ❑ Azimuth:156° o Pitch:35° N Monitoring System: 6 SunPower Panel/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 3/4"X 165 5/8" Surface: 7 Magic*Invisimount Legend: 15 SunPower 360W Panels SunPower Invisimount Rail • 28 UniRac Drk Standoff 7 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: DCjA R D 16,, �Q'f 4� O F N.- Drawn By:MADrawing#6 of 8 Date:411/2022 REV:A Drawing Scale:3/16'=1.0' J ' No Vent Pipes Will Be Covered By The Solar Array :LOGIC" Legend: GreenLogic,LLC Approved Lufrano,Leonard AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge 610 Lupen Drive per R202 definitions per R324.6.1 as per R324.6.2.1 Cutchogue,NY 11935 Taal system size:28.040kW 1 circuit of ll an a 20A breaker 1 circuit of 10 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 10 on a 20A breaker 1 circuit of 9 on a 20A breaker 4 1 circuit of on a 20A breaker b \ 1 Circuit of B on a 20A breaker Meter A21muth:156° Monitoring System: N SunPower Pand/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Surface:83'8"X 45' Magic#:Invisimount Legend: 0 64 nPower 36OW Panels I 1 I ( — SunPower Invisimount Rail I 1 • 110 UniRac Drk Standoff I I AR BB API IAP 2x10"Douglas Fir Rafter 16"O.C. I I a Notes: i 1 Number of Roof Layers:1 I I Height above Roof Surface:4" L---------------------1 _________ ______ Materials Used:UniRac,SunPower SVo --- fl Added Roof load of PV System:2.84psf svo Engineer/Architect Seal: NV QAP <�_D ApLKJp t-- � /.� � AN F V d n I X1 x1m X1 AN A' tStZt A% A% Al NE NK Ny Ny 49 SunPower 15 SunPower 360W Panels 36OW Panels b r wn ByDrawing#7 of 8 :4/7/2022 REV:A wing Scale:1/16"=1.0' LOGIC i + Green Logic,LLC Approved Lufrano,Leonard 610 Lupen Drive JOB MATERIAL LIST Cutchogue,NY 11935 Total System Size:23.040kW . 1 circuitof 11 on a 20A breaker 1 circuit of 10 on a 20A breaker 1 clrcultof 9 on a 20A breaker 1 circuit of 10 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 c rcuitof 7 on a 20A breaker 1 circuitof B on a 20A breaker i Azimuth:156° i Material List Qty. Rail Material list 0t . Monitoring System: N SunPower Pand/Array Specifications, Uni Rac 4"Drk Standoffs 110 Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount 5/16"x4.5"SS Lag Bolts 220 Panel:61.39"X 41.18" Surface:83'8"X 45' 5/16„Stainless Steel Washers 220 Magic# Invisimount Oatey 12920 Flashing(Silver) 40 Legend: Oatey 12920 Flashing(Black) 70 ;-..t. 64 SunPower 36OW Panels SunPower Invisimount Rail • 110 UniRac Drk Standoff 2x10”Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:i Height above Roof Surface:4" j Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf j'. Engineer/Architect Seal: Xf CLTnG =�T 02 033 • �' Drawn By: Drawing#8 of 8 Date:4/712022 REV.A Drawing Scale:1116"=1.0' UTILITY SERVICE: 120/240 1 PH, 3W CUSTOMER r UTILITY REVENUE METER RM 300 AMP, 250V JAN 05 2023 L J (EXISTING) BUIIDING®EPT TOWHOFSOMOLD AUTOMATIC GENERATOR TRANSFER SWITCH SERVICE DISCONNECT SERVICE DISCONNECT � __0 150A 150A MAIN MAIN i - - - _ DIST BUTTON, TYP. CRITICAL LOADS SUB-PANEL _ D TAP SWIT q q -DSC-1 150A DISTRIBUTION TYPICAL -- -- -- -- NEMA-1, FUSED SAFETY SWITCH AC-CMB-1 250V, 100A, NEMA-1 MAINf20A) 20A) 20A) 20A) 20A) 20A) 15A O ) � I f ' I�� I I I I I I � I I I III I I I I S I III I I I 1 1 � PROPOSED ELECTRICAL SCHEMATIC NEW EQUIPMENT ra-i LaJ K_I La-1 LaJ Lai ra--- Lufrano, Leonard REVISIONS P 610 Lupen Drive EOAR� y<E1\ � ; LOG W Cutchogue, NY FE�* 2.) AS-BUILT CONFIGURATION EUMINATING THE COST OF ENERGY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION a, 3�yo �F,NE Page 1 of 5 Drawing No: LL610-3LD2 Revision: 2B Revised: 12/31/2022 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 21.120 kW (PV) TOTAL KW RATING: (DC POWER) 23.375 kW (PV) QTY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL: SPR-M425-BLK-H-AC 55 PV MODULE: (SPR-M425-BLK-H-ACJ 425 W DC(NOMINAL), EACH SUNPOWER BRAND, MODEL: SPR-M425-BLK-H-AC(IQ7AS) 55 PV INVERTER: (INTEGRAL TO MODULE) 384 VA, 1.60 A, 240V AC, EACH PROPOSED 3-LINE ELECTRICAL DIAGRAM Lufrano, Leonard REVISIONS 610 Lupen Drive h u Cutchogue, NY ENE 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 5 Drawing No: LL610-3LD2 Revision: 2B Revised: 12/31/2022 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 7-MODULES PV-5A-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 9-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 9-MODULES PV-5A-4 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-5 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-6 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 10-MODULES BKR-1 ...BKR-6 CIRCUIT BREAKER, PV-SA-1...PV-SA-6 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-CMB-1 AC COMBINER PANEL 250V, 100A, NEMA-1, 1-PH, 3-WIRE, 100A MAIN BKR AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 25OV, 100A, NEMA-1, FUSED; FUSE RATING: 100A PM-1 PV POWER PRODUCTION MONITOR SUNPOWER PV SUPERVISOR, MODEL PVS6 PROPOSED EQUIPMENT SPECIFICATIONS Lufrano, Leonard REVISIONS 610 Lupen Drive ' ' Cutchogue, NY E Y 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 5 Drawing No: LL610-3LD2 Revision: 2B Revised: 12/31/2022 ELECTRICAL LOAD SUMMARY, AC CIRCUITS TAG POWER, MAX VOLTAGE MAX. AC VOLTAGE, NOMI- RANGE CURRENT NAL PV-SA-1 2,688 WATTS 211-264 VAC 11.20 A AC 240 V,AC PV-SA-2 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC PV-SA-3 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC PV-SA-4 3,840 WATTS 211-264 VAC 16.00 A AC 240 V,AC PV-SA-5 3,840 WATTS 211-264 VAC 16.00 A AC 240 V,AC PV-SA-6 3,840 WATTS 211-264 VAC 16.00 A AC 240 V,AC PM-1 35 WATTS 240 VAC 0.20 A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS Lufrano, Leonard REVISIONS ' R;E 610 Lupen Drive � E Cutchogue, NY E iN= Y 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION Page 4 of 5 Drawing No: LL610-3LD2 Revision: 2B Revised: 12/31/2022 CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 3/4" PVC-40 12 / 12 C THWN-2 1-1/2" PVC-40 1 / 6 D THWN-2 1-1/2" PVC-40 1 / 6 1.) CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Lufrano, Leonard 610 Lupen Drive ' ' Cutchogue, NY �` ENERGY 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION Page 5 of 5 Drawing No: LL610-3LD2 Revision: 2B Revised: 12/31/2022 1 � �- - NEW EQUIPMENT------ - EXISTING SERVICE EMERGENCY AC ---------- ----- EQUIPMENT-------------------- 120/240, 1PH, 3W STANDBY GENERATOR (TYPICAL SYSTEM SCHEMATIC, i FINAL INSTALLATION MAY VARY, REQUIRES LOCAL AHJ 300A K W H PV-SA-1 A AND UTILITY APPROVAL) 41 FmT,• AC-CMB-1 N • • • 2 1 AC-COMBINER PANEL u NEMA-3R, EXTERIOR / J ---- - — I (PV ONLY) B I TYP. PV ARRAY AC-DSC-1 ' TYP. (6) CIRCUITS MAIN AC DISCONNECT C (TAP SWITCH) i I A B N I PV-SA-6 A I BKR-1 . . . I 150A ATS N -• • • 2 1 - I BKR-N MAIN A B N TYPICAL PV MODULE WITH I I BKR-M 150A INTEGRAL DC/AC INVERTER I I II � II I i N 150A I PM-1 EGC N Y-9 MAIN ' I i EGC D I MBJ EGC A B N ' I I MAIN C/T I AC DISTRIBUTION I I EW EGC I (NON-CRITICAL) 6CU MIN. L---------------- -L-_�- -------7---� N --- ---_--IRREVERSIBLE BOND, TYP. --- I I -__- _-__-__-__-__-__�J EXISTING1GEC EGC AC DISTRIBUTION (CRITIAL LOADS) Lufrano, Leonard REVISIONS 610 Lupen Drive ¢o� E�s°y^FA- E E LOG IC® Cutchogue, NY ct ENERGY 2.) AS-BUILT CONFIGURATION \a,��==63'�oPt ELIMINATING THE COST OF ENERGY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION OF NEN Page 1 of 5 Drawing No: LL610-3LD2 Revision: 2C Revised: 2/20/2023 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 21.120 kW (PV) TOTAL KW RATING: (DC POWER) 23.375 kW (PV) QTY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL: SPR-M425-BLK-H-AC 55 PV MODULE: (SPR-M425-BLK-H-ACJ 425 W DC(NOMINAL), EACH SUNPOWER BRAND, MODEL: SPR-M425-BLK-H-AC(IQ7AS) 55 PV INVERTER: (INTEGRAL TO MODULE) 384 VA, 1.60 A, 240V AC, EACH PROPOSED 3-LINE ELECTRICAL DIAGRAM Lufrano, Leonard REVISIONS 610 Lupen Drive oyE ° TyFA R EEN LOG ICO Cutchogue, NY ; ENERGY _ 2.) AS-BUILT CONFIGURATION "� 'oz�63'�o^r ELIMINATING THE COST OF ENERGY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION �. OF NEN Page 2 of 5 Drawing No: LL610-3LD2 Revision: 2C Revised: 2/20/2023 c' EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 7-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 9-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 9-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-5 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-6 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-BLK-H-AC, 1-CIRCUIT OF 10-MODULES BKR-1 ...BKR-6 CIRCUIT BREAKER,-PV-SA-1...PV-SA-6 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-M CIRCUIT BREAKER, PM-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 15A AC-CMB-1 AC COMBINER PANEL 250V, 100A, NEMA-311, 1-PH, 3-WIRE, 150A MAIN BREAKER AC-DSC-1 AC DISCONNECT(LINE TAP) 25OV, CIRCUIT BREAKER, NEMA-1, RATING: 150A,SERVICE RATED PM-1 PV POWER PRODUCTION MONITOR SUNPOWER PV SUPERVISOR, MODEL PVS6 PROPOSED EQUIPMENT SPECIFICATIONS Lufrano, Leonard REvisioNs 610 Lupen Drive ��PE°A"`y REE L.OGICO `+ EzSr F ENERGY Cutchogue, NY t 2.) AS-BUILT CONFIGURATION 21E33 Oe ELIMINATING THE COST OF ENERGY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION OF NEN Page 3 of 5 Drawing No: LL610-3LD2 Revision: 2C Revised: 2/20/2023 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX. AC VOLTAGE, NOMI- RANGE CURRENT NAL PV-SA-1 2,688 WATTS 211-264 VAC 11.20 A AC 240 V,AC PV-SA-2 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC PV-SA-3 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC PV-SA-4 3,840 WATTS 211-264 VAC 16.00 A AC 240 V,AC PV-SA-5 _ 3,840 WATTS . 211-264 VAC 16.00 A AC 240 V,AC PV-SA-6 3,840 WATTS 211-264 VAC 16.00 A AC 240 V,AC PM-1 35 WATTS 240 VAC 0.20 A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS Lufrano, Leonard REVISIONS �EpEo aR� 610 Lupen Drive S �S�.sTyrFEENLOGIC�' Cutchogue, NY t EN ERGY 2.) AS-BUILT CONFIGURATION a,�o„ SSyo� ELIMINATING THE COST OF ENERGY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION Pa e 4 of 5 Drawing No: LL610-3LD2 Revision: 2C Revised: 2/20/2023 y �, CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 10 / 6 B THWN-2 1-1/2" PVC-40 1/0 / 6 C THWN-2 1-1/2" PVC-40 1/0 / 6 D TH W N-2 3/4" PVC-40 12 / 12 1.) CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM PROPOSED EQUIPMENT SPECIFICATIONS Lufrano, Leonard REVISIONS 610 Lupen Drive ��r��5�s REENLOGICO Cutchogue, NY ENERGY 2.) AS-BUILT CONFIGURATION \''FbcNej++°Pr ELIMINATING THE COST OF ENERGY 11935 1.) INITIAL SUBMITTAL WITH APPLICATION Page 5 of 5 Drawing No: LL610-3LD2 Revision: 2C Revised: 2/20/2023 T OCCUPANCY OR pPPRO Ep AS N0 �� USE IS UNLAWFUL WITHOUT CERTIFICATE DATE: S� B.P. OF OCCUPANCY FEE BY: r NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION -"TWO REQUIRED FOR POURED CONCRETE 2, ROUGH - FRAMING & PLUMBING 3. INSULATION toMPLY WITH ALL CODES OF 4. FINAL CONSTRUCTION MUST NEW YORK STATE & TOWN CODES BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE qS REQU RED.AND.CONDITIONS OF REQUIREMENTS OF THE CODES OF NEW $p11THOLD TOWN ZBA FORYORK STATE.ECONSTRUCTION RESPONSIBLE DESIGN RERRORS. SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES DEC w%mr^wp%,l" U,yOFF WA1ER R RETAIN STORM CHAPSER 236 PURSUANS SO CODE. ��SHE TOWN fill III IILjIIIL_P= 111111, fill III I JAMES J. S TOUT A R C H I T E C T & Assoc. 2 G REG L ANE E AST NORTHP01? T N. Y. 631 — 85a 9388 Letter of Certification April 7, 2022 RE: Lufrano Residence 610 Lupen Drive Cutchogue, NY 11935 To whom it may concern: I, James J.Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above- mentioned address and have determined the structure and the attachment to be adequate to support the new additional load imposed by the proposed solar system and complies with the 140-mph wind design load as per 2020 Residential code of NYS(RCNYS),2020 building code of NYS(BCNYS)residential code,2020 Energy conservation construction code of NYS(ECCCNYS)and the 2017 National Electric Code NFPA 70/2017 National Electric Code, and the ASCE 7-16. The existing 2"x 10"@ 16"o.c. roof rafters will provide adequate support. James J.Stout Architect ,'�&tE D \� nes i S 7- . '�!V� �Pb •�.,,-� OGS, r IF OF NES NEW EQUIPMENT EXISTING SERVICE . • - ;nr AC—COMBINER PANEL 120/240, 1 PH, -3k/V • • 2 1 -ells-1 1 (PV LOADS ONLY) i ?hl I 'V PV-SA-3 FMI . . . - - BKR-1 Av—DSC-1 _ • • • zft AC DISCONNECT PV-SA-4 • • • BKR-3 • • • 1 _ PV— —5 ' :" BKR-4 RAIN —� ft I • • • BKR-5A B N IV FUSE© ' o PV-SA-6 BKR-G P 1 . . . 6KR-7 EGG RV-SA-7IF I N _ l ff rsr _ i I�I • • • 1 EGG 17 ! 3z3 EGc ! EXISTING AC PAN TI XISTING GEG -GEC 6 CU 23.040kW DC 20.160M AC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Lufrano, Leonard 610 Lupen Drive cl, ll ENERGY � � u� Cutchogue, NY 11935 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Lufrano-3LD1 Revision: 1 Revised: 2/2/22 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES PV-SA-2 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES PV-SA-3 PV SUB-ARRAY SPR-X22.360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES PV-SA-4 PV SUB-ARRAY SPR-X22-360-E-AC EN PHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES PV-SA-5 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES PV-SA-6 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES PV-SA-7 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 4-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 . 3600 WATTS 211-264 VAC 14.64 A AC 240 V, AC PV-SA-2 3600 WATTS 211-264 VAC 14.64 A AC 240 V, AC PV-SA-3 3600 WATTS 211-264 VAC 14.64 A AC 240 V, AC PV-SA-4 3600 WATTS 211-264 VAC 14.64 A AC 240 V, AC PV-SA-5 3600 WATTS 211-264 VAC 14.64 A AC 240 V, AC PV-SA-6 3600 WATTS 211-264 VAC 14.64 A AC 240 V, AC PV-SA-7 1440 WATTS 211-264 VAC 7.75 A AC 240 V, AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS t ( EESLOGIC' Lufrano, Leonard 610 Lupen Drive Cutchogue, NY 11935 ERGY ELIMINATING -ERE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION --Page 2 of 3 Drawing No: Lufrano-3LD1 Revision: 1 Revised: 2/2/22 s EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V,200A, NEMA-1, 1-PH,3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-3 CIRCUIT BREAKER,PV-SA-3 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-4 CIRCUIT BREAKER,PV-SA-4 MATCH AC COMBINER PANEL BRAND,2-POLE,20A - BKR-5 CIRCUIT BREAKER,PV-SA-5 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-6 CIRCUIT BREAKER,PV-SA-6 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-7 CIRCUIT BREAKER, PV-SA-7 MATCH AC COMBINER PANEL BRAND,2-POLE,20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V,100A,NEMA-1, FUSED; FUSE RATING: 100A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4"PVC-40 12 / 6 B THWN-2 2"PVC-40 4 / 6 C THWN-2 2"'EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE,DISTANCE,AND DERATING FACTORS. 2.)ELECTRICAL CONDUIT TO BE MIN.PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Lufrano, Leonardi'_lL.N LOGIC ` � m 610 Lupen Drive ': ✓ Cutchogue, NY 11935 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Lufrano-3LD1 Revision: 1 Revised: 2/2/22 LOGIC G►eenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#A: Total System 3.040kW Array Sze:17.64Ok640kW 1ckcult of 11 on a 20A breaker 1 circuit of 10n a 20A bre alar 1 circuit of 9 cn a 20A bra alar 1 circuit of to on a 20A bra akar � 1 circuit of 9 an a 20A bre alar Azimuth:156° Pitch:35° Monitoring System: SunPower Pand/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:48'10 IM"X 20'7 3/4" Surface:49 T'X 22'6" Magic t Invisimount Legend: Q 49 SunPower 360W Panels SunPowerinvisimount Rail • 82 UniRac Dirk Standoff 8 2x10"Douglas Fir Rafter 16"O.C.X/1\ A\ ' I Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: j tED ARc - !�^C-;,,tJ`ES J S TCG�T E' DAPR 1 8 2022 BUILDING DEPS: � 021 33 ,OQ" TOWN OF S0UTH0LL; Drawn By: Drawing#1 of 8 Date:47/2022 REV:A Drawing Scale:1/8"=11.0' I : LOGIC' GreenLogfo,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#A: Total System Size;23.=kW Array Sze:17.640M 1 circuit of 11 on a 20A breaker 1 circult of 10 one 20A bre akar 1 circuit of 9 on a 20A breaker i circuit of 10 on a 20A bre aker 1 circuit of 0 on a 20A breaker Azimuth:156° Pitch:35° Monitoring System: N SunPower Pand/Anray S clfications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:48'10 1/4"X 20'7 314" Surface:49'7"X22'6" Magic A Invisimount L end: 0 49 SunPower 360W Panels SunPower Invisimount Rail • 82 UniRac Drk Standoff 8 2x10"Douglas Fir Rafter 16"O.C. 14 \41 Notes: Number of Roof Layers:1 XUDI I h 'A 11 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: r!-rGDA C .-S J STp qT 02 N E`N Drawn y:M Drawing#2 of 8 Date:4M2 REV:A Drawing Scale:1/8"-=1.0, ?'^ LOGIC° GreenLogfc,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface.#A: Total System Stce:23.040kW Array Sze:17.640M 1"oe'I of 11 on a 20A beafar 1 ckarlt of 10 on a 20A breaker t 1 drea of 9 on a 20A breaker 1 ekwitof 10 on a 20A breaker 1 ctallt at 9 on a 20A breaker Azimuth:156" Pitch:35" Monitoring System: N SunPower Pand/Array Specifications: Panel:SPR-X22-360•E-AC 1 3 Racking:SunPowerinvisimount Panel:61.39"X 41.18" Array:48110 1/4"X 20'7.3/4" Surface:49'7"X 22'6" Magic*.Invisimount 1 1 2 4 Legend: 0 49 SunPower 360W Panels SunPower Invisimount Rail 1 2 5 4 • 82 UniRac Drk Standoff B 8 2x10"Douglas Fir Rafter ot,zzl, Notes: Number of Roof Layers:1 1 2 5 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: - r` G k o .Q p� Drawn Drawing#3 of 8 Date:4/7/2022 REV:A r Drawing Scale:1/8"=1.9 ;LOGIC° Greenlogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#B: Total System Size:23.040kW Array Size:5.400kW 1 circuit of 7 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:156" c Pitch:35" Monitoring System: N SunPower Pand/Affay Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 3/4"X 15'5 5/8" Surface:34'1"X 22'2" Ma is#:Invisimount Legend: 15 SunPower 360W Panels SunPowerinvisimount Rail • 28 UniRac Drk Standoff 19 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: FED qpc . v �4' •fin. (;* ��� ATF ���<1 G33 40 ��� • Drawn By:MA Drawing#4 of 8 Date:4/7/2022 REV:A Drawing Scale:3116"=1.0' y' <t ,LOGIC by GmenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive Cutchogue,NY 11935 Surface#B: Total System Size:23.040kW Array Size:MOM 1 drouk of 7 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:156" Pitch:35" Monitoring System: N SunPower 4 Pand/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39'X 41.18" Array:24'4 314"X 15'5 5/8" Surface:34'1"X 22'2" Magic#:Invisimount Legend: 15 SunPower 36OW Panels SunPowerinvWmount Rail • 28 UniRac Drk Standoff 00 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers,1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Rcof load of PV System:2.84psf Engineer/Architect Seal: r Ap Si 41 hF ty 6F \\9T X216 yp D NEVI • Drawn By:MA Drawing#5 of 8 Date:4/7/2022 1 REV:A Drawing Scale:W16"=1.0' 1 " :LOGIC' GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive i Cutchogue,NY 11935 Surface#B: Total System Size:23.040kW Array Size:5.400WV 1 circuit of 7 on a 20A breaker 1 circuit of 8 on a 20A breaker ❑ Azimuth:156" i 0 Pitch:35" N Monitoring System: 6 SunPower Panel/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 3/4"X 15'5 5/8" Surface:34'1"X 22'2" 7 Magic*Invisimount Legend: 15 SunPower 360W Panels SunPower Invisimount Rail • 28 UniRac Drk Standoff 00 2x17 0"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf 1 Engineer/Architect Seal: �Gp.ED ARRC ^ES J S TOG 0 16z �O c OF N� • Drawn By:MA Drawing#6 of 8 Date:41112022 REV:A Drawing Scale:3/16"=1.V No Vent Pipes Will Be Covered By The Solar Army L®CICO Legend: GreenLogic,LLC Approved Lufrano,Leonard AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge 610 Lupen Drive per R202 definitions per R324.6.1 as per R324.6.2.1 Cutchogue,NY 11935 Total System Size:23DOM 1 circuit of 11 on a ZOA breaker 1 circuit of 10 on a 20A breaker 1 circuitit of 9 on a 20A breaker 1 circuof 10 on a 20A breaker 1 circuit of 9 of a 2DA breaker 4 1 circuit of B on a 20A breaker \ 1 circa it of t)on a 20A breaker Meter Azimuth:156" Monitoring System: SunPower Pand/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower lnvisimount Panel:61.39"X 41.18" Surface:83'8"X 45' Magic#:Inv!simount L end: 64 SunPower 36OW Panels 1 I I I � SunPower Invisimount Rail 1 I • 110 UniRac Drk Standoff I I AR B8 API IAP 2x10"Douglas Fir Rafter 1l O.C. l I 1 I Notes: I 1 a Number of Roof Layers:1 I 1 Height above Roof Surface:4" L_____________________I _______ ______ Materials Used:UniRac,SunPower SVO Added Roof load of PV System:2.84psf AIL A --- fl Svo Engineer/Architect Seal: IAP � ,�¢ALJ X, \�- J J S AN AN A 0 G33 49 SunPower i �0�1 �F 36OW Panels 15 SunPower 36OW Panels Drawn By: Drawing#7 of 8 Date:4/7/2022 REV:A Drawing Scale:1/16"=1.0' ` I _ - LOG IC® GreenLogic,LLC Approved Lufrano,Leonard 610 Lupen Drive i JOB MATERIAL LIST Cutchogue,NY 11935 Total System Size:23.040kW 1 circuit of 11 on a 20A breaker I 1 circuit of 10 on a 20A breaker 1 circultof g on a 20A breaker 1 circuit of 10 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuitof7 on a 20A breaker '• 1 circuit of B on a 20A breaker Azimuth:156" Material List Qty- Rail Material list t . gY �.. Monitoring System: SunPower Pand/Array Specifications: UniRac4"Dirk Standoffs 110 Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount 5/16"x4.5"SS Lag Bolts 220 Panel:61.39"X 41.18" Surface:83'8"X 45' . 5/16„Stainless Steel Washers 220 Magic P.Invisimount Oatey 12920 Flashing(Silver) 40 Legend: Oatey 12920 Flashing(Black) 70 1117-71 64 SunPower 360W Panels �( SunPower Invisimount Rail I; • 110 UniRac Drk Standoff 8 2x10”Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.84psf En neer/ArchltectSeal: FED ARC f , Es�s r�, 'yij, 0 IN Drawn By: Drawing#8 of 8 FDate:4/712022 REV:A Drawing Scale:1/16"=I.V I SUNPOWER SunPowerO -Series: X22-370 X22-360 SunPow&RResidential AC Module Built specifically for use with the SunPower Equinox"system,the only fully integrated solution designed,engineered,and warranted by one manufacturer. Maximum Power. Minimalist Design. Inclustry-leading efficiency means more power and savings per available space.With fe�,er modules required and hidden microinverters;less is truly more. Highest Lifetime Energy and Savings. Designed to deliver 500A more energy over 25 years in real-world conditions like partial shade and high temperatures.' ............ ............ .. .......... .............. . .. .. 610'46 -- Fgnda entally ®iff rent. • And Better. -- 170M1; Up t0 Better. A 'low 60% leoc; :mare ' e eo4, lifetime Ln GOO :rw The Sun Power"Maxeonl-�Solar Cell Years of operation Chab!e::,hrgltest-e�rit:lency moduleiiia bI Urlmatc^ed r iiai i'ity' • Pat:rated solid afetal fc:ndation Best Reliability. Best Warranty. Prevents breakage a6dcon-osion With more than 25 million modules deployed around the world,SunPower technology is proven to last.Thais s why we stand behind our module and microinverter with the industtys best 25-Year Combined Power and Product Warranty,including the highest.Power Warranty in solar. Factory-integratedMicroiriverter • ;im,rl^,faster inst�-rliatc� •' Integrated,rare manatierrleru, aa, �"vV• r:�piri :hui.doVvrr °a <M1;: .� ,.•. • Engln^erc' y d and a c 'ib at�d b. B .o ;more unPower for +an as,:.>-mod les = power s_a, & ' :"" v in year m srn� 25 o to Is 2c ,s Years of operation Datasheet X-Series:X22-370 X22-360 Su n Power"t Residential AC Mcdqle...,' r. Inverter Model:Enphase IQ 7XS(IQ7XS-96-ACM-US) @240 VAC- @208 VAC ........................-"---...............................................................................................----............................................................................ 0,,aK OumtA Power 320 VA320 VA ............... May.Contlritjolj:>Outowl,Po"e-jer 31 VA 315 VA 208/'18.3-229 24'0./2:: ..................................................................... . ... ............................................................................................................................. .................................................... ----- - Outou.- (A) 51 1.31 . - .......... ........... . .............. . ........................ Max.Units Per 20 A(LL;Brjrlcjj Cjrcj.ilr3 2(s:nge phase 10(two PC"1-2)wye ........................ ............--'—'-...- — '-'----- --- - --------.................. C7",-."'y".ighteti Effi,:!ency 97.iiyo 97 OWj Norn.F-r-:-qucn(.,/ 60112 ..............................................................................................................................................................................................................................................................................- ........................................................................................................ ................................................ E),ten-'ed F.'requency 68 J'i7 ..................... .......................................................................................................................................... ...................... ...........................--7 7'' ................................. A.0 Short.Circuit Fault Ct-rrertt Over-3 rynes 5.8 A rms OvervolIage Port A(-Port 3ac,14eed Current 18 mA ...................... ....................... .............. .............- ......... S5(t:ng 1.0 .......... .......... ........... ............ ......................... ....... .......................... . ................... O.-Tlead.10.7 lag. ...........-- .............. .......... .............. No acovel:yhasE balancing ......................................... DC PbData Mrrantits, SPR-X22-370-E-AC SPR-X22-360-E-AC25-.year limited pouter;varranty VV'a r r a I i t I e s 25war limitcdproduct war ranty mominal POWe!'`(PnOln' 370 W 3CO W i .................................................. .......................................... ........................................................... ........... ...............1 1,111703 FlPow-er-Tolerance-- -- ----- I -is -UL'741/IFEE-1 S47 Module Eff-dency 22.7t,'� I cleiu iczu,! l,JI_1-741 AC Module Type 2 fire rated) ....................................... ......... ......................... ................. ......................... and 7e UL 62109-1 'IFC 62'09-2 ,11p.Coal.(Power) 0.291/&/-'C Compliance ............................... ..................................................................... •FCC Part 15 Class I, 'three bypass diodes ICES 0003 Class 9 ShadeTolerance, integrated module-level maxifnuni CAN./CSA-C22.2 NO. [07.1 01 power point trackng CA Pule 21(UL 1741 'Includes VoltiVar ard ReactIV l e Power Priority) Tpted OperaftPH'Itions UL Lisced PV Rapid Shu'down Equipme. Operating it CmP. -40°F to+;I 40'F(-dVC to+60'C) ,_sables installation in accordance with: KAlax.Arnt-,ient Terrip. 122'F(50-C) NEC 690.6(AC module) Wind:62 psf,3000-Pa,3015 kg/rril frons&back N1.'C 690.12 Rapid Shutdown(inside and outside the array) 1 lvlax.-oad Snow:125psf,6000 Pa,611 kg./M-411,on' NEC 690.1 1-1 AC Connec:clrs. .. ..................................---................................. Impact 1 inch(25 nim)-diameter hail at 512,rri.ph(23 mis) -- When used with I-visiMount iack'n,-,and IIvisiNlount accessories Mec,hani(81 D (U!a at 2703): %4-odUie grounding and bondingthrough Invisilvlount, Solar Cells 95 Monctcr�stallirle Maxeon Gen III . ................ ..............I.................. . . ........................... ..... .. . ....... •Class A fire rated High-transmisslon tempered glass When used vlich AC rflodule Q Cables and accessories(UL 6703 and Frort Glass anti r'eflect'ive coaclrl�. UL 2233)1: Environmental Rating Module:Outdoor rated Rated for load breal,disconnect ........... ................................. ........................I Inverter.NEVIATIVpe 6 Class 11 PID Test Potential-induced,degradation free .................................................................................. ............. ................................... .................... Frame 1@7s I black anodi7ed'highest AAL. ratin-) • ...................................................................................... ............ ..................................... .......................................... Weigric, 42,9 Ib(19.5 kg) ............ Recu,T mierided Max. 1.3 in.(33 mm) MadUle Spacing ........... 4,Am 1 SunPutver 360 W compared to I,conventional module or,,sarne-sized arrays(26 0 IN,1 646 efficient,a ppr ox.1.6 m2),4 Vj more emn ergy p e r wea L;(ba z-'e 6 on third-party module d o -Pyt, w slob r d egra d at i o n(Cam peau,;'. "So n Powter A:I ion and PvSiml, .7 F aracrerizat — Odule Deg!'adation Ram": 'Unflowerwhite parter,201x`;. s to mea 3o»un 2Gasedonsearchofdatai>'neetv:;lue>fromvvehsitesoilap'Orrvaruiacurers:perlHS.;sol in} lanu,*-iry 2017. rank in"Fraunt,ofer"IV It iWative for Solar Mod Li IeF,�Part 1"PVY�f h:3ower Paper,2013. MG mm 4 Pactory set,to 1 defaLtit sclaIngs.U,Rut le'-,'defaul csei"Ungs profileset dL1rilI9 (15 5 to') comr iN5ioning.See the Equinox installation G-.-,Ide#51$`:01 rot more information. 5 Standard Test Condidons i I OCO WirW irradiance,AM 1.5,25'C).NREL ca!i:.)r-,!on Standard:M"AS COrrem,LACCS IFF and Voltage.All UC voltage is WIN contained vvichm the module. , C:his Product is UL Listed as PVRSE;)rid conforms!Pvith NE(:2014 arid NEC 20 17 690L12; (17a 14.1 aod 022.1-2015 Rule 64-211�Ra'old shutdown of PV systems,for AC and DI:conductors;wher,installed according to manufacturer's instruc,tons, = . I See wmorw,.stnpoweern xmcn-et fdormord:re fere n c e i-form I t!rn. UO@ L '�F1AWD�N UNP ter medetails, e etcd stasheet USTEB�7=0 SWER Snecificatons included in this dotasheet aresubiec,to change without nonce. J 2018 5UnPowe!'Corporation.Aif Rights Reserved.SUNPOWER,the Module Fite Type 2 SUNPUAIER logo incl MAXEON are registered trademarks ol'SurtPower Pieise read the&;feky and In5tallation im�trucdons for dLta,15. 531945 RevA Corporation in the U.S.and other countries at,well,1 sunpwerxom Simple and Fast Installation --- Irtegrared-mc'dule-.o-rail grbuncing Prp -c sennblezd mid and end damns - I..evitaring mid damp,For easy p,lac.ernent. Mid clanir,wldrh'i,:acillta!'FS'on lSt'nt even E 1-nod uiE'.`:p�1,:lI"1Q Simple,p,e­,';rilled rail sr,)i,-e 4 L 703 Listcc9 rtlourated rcir;nOflng F lexi )le Desi�.l • /tddCC"asC:s"i{?zirl.p'all Slot)f' rr'Sdt'ntOl I`<,;(JfS • rJt;=sl€;n in landscapeand p0n-."'c1i'i, Fails& 't)!z{easy obst.cle rnanagem.en Custorner-Preferred Aesthetics _.._ .........._.. -.,_ zftl r:.ordule an;d#" n-ount n g aestl,mics Best-in-class system-aesthetics Elegant Simplicity Prernium,low prof le design Rack anodized components SunPower' InvlsiMount11" Is a .StinPower-designed Ridder m d damps and end carnes rail-based mounting system.The Invis'Molunt.system and capper,tlusn rail addresses residential sloped roofs and combines faster Part of Slaoerior System F y installation time, cfc'slgr.l flexibility, and superior aesthetics. B lilt ror lase wft�,Sunpov er DC_and AC mocules The InvisiMolant produce was specifically envisioned and Best-In-das s sy sten-!.reliability and aesthetics erw -ieer-ed to .)pair with SunPo�wer modules. The resulting i_t..mnine'w:.` unPo,,.ver!-nodu,es and I monit.orirg ar:n systern level approach will amplify the aesthetic and installation benefits for both homeowners and installers. a '�:: �<:.�..} • . a� tee. sunpower.Com 777 `fit"$. "�,•f.,.tz .i�'„°s.e.b✓`',., .v;m.,re�,,,!�•,{ A r g R �v� • i Modu'e*i M!ci Clamp and Rai'! Module*i End Clamp and Rall Mid Ciamc nd Clamp Rail K Rail Splice Ground Lug Assembly End Cap a Terrlperature -»0°C to 90°C(--40°F to 194'F1 Component Material trJei hti....................................._-............ -- -.........._.._...............- .......__.._.................................._...... -�- - — Max.Load(LRFD) 3000 Pa uplift Mid Clamp --- [lack oxide stainless steel;1151 304 63 g(7.2 oz) 6000 Pa don;!;tortP................_._.....-- ------..__... ... End Clamp Black anodized alurninurn alloy 6063-T6 110 g(3.88 oz) Rail Black anodizod aluminurn alloy(6i)05-1'6 830 girn(9 oz/ft) ' I Rail Splice Aluminum alloy 6005-T5 830 g/m(9 oz/ft) 25-year proquct warranty' War arue G,ounce Lu 304 szai!ress ! � g 106.5>;hr:(3.75 oz) � 5-year fins^v�arranty Assembly (A2-70 bolt;tin-plated copper:uf;) -- _ -- - -----._....................._..................I................................................................. -- . .............................. l End Cap Clack acetal(f Oht)copolymer 10.4 g(037 0") �........... --._........................................_._....._...._...._..I....... --- ---- 03,' .ed ' Certifications l L 27 U­ Pd ! Class A Fire Rated " i Comnostion Shingie Rafter Attachment Compos:rum Shirngle Roof Decking Attachmnte ® " Application a a j ' Curved and Flat Tile Roof Attacnrnent' I Universal Interface for--her Roof Attachments I Refer to roof attachment hardware mar ufact!:ret's.iocumentation. *Morl-ile frame that is comparable with the Inv^siMount syetem required for hardware interoperability. , 2.115 SunPower Corporation. All Rights Renewed.SUNPOWER,the SUNPCWER Toro,and INVI.S3NOUt9T are trademarks or r egis;ered trademarks of SunPower Corporation.Ali other trademzrks are the pi rperty of their respective owners. illrlpe4Ver:'..^.m Specifications included in this data>heer are subject to change without notice. Document 4504506 RevC i uv� a. _ p, ,X rel. ','Flq•" ,�' ^' ,._ •x 'i_...-,.:}�°, .ow�..,�i .:� Y'. •moi-'&'.v,y ti. , l M 711 yy 63 Improve Support, Reduce Maintenance Costs SunPower EnergyLink—Plug-and-Play Installation An intuitive monitoring v'rebsi e enat)lc5 you to: This complete solution for residential a:id conxnercial rnonitorim—and See a visual mar?of culs_orner sites '-._ontrol Irutdes Ine�-unF_wer'"'PV Suaerwsor G(PGSu)whir improves Remotely rnanage hundreds of'sites the installation process,overall system reliability,and custorner Receive elec ive systern ref;orts experience. Ci:CE 5'SCE,"r"I issues ir'C`IErrlQtEl t ii• OSE Corn )act Dot print for improved aesthetics ...y.. y g,r` f:c f:. 1.)iagnose issues online Robust cloud connectivity and cornpre'r.ensive local connectivity Drill cJc;r+n for the status o' nd':icil;al devices Flexible configuration of devices during installation Consumption metering w_ -7=7Revenue-grade production metering(pending) Weh-based commissioning ry Rerr::ote_diagnostics of PVSE and inverters Durable UL Tvpe 3R erIClOS;re reduces maintenance costs Easy integration with SunPowe-eBOS Add Value for Customers \Kith the SunFawer t�At;nitorinQ System Robust Cloud Connectivity .Iv, customers can: _ .. ?r< Muiitiple options to maintain optimal • eP.,what TI-leis SOIar sXst::rrl produces each ,r' ° connectivity: day,month,or year Hardwires Ethernet Optimize:heir solar investrnent and save on Vtii Fi enemy expenses Cellular backup See Meir enemy use and estin;ated bili savings See their solar system's performance using the Stlnf:'Ower moni_oring vaeusite or mobile app - } F i£ D. f _ , : �L ae• SunPower Monitoring Websites PVS6 SunPower AC Modules x 1 ! � Multiple communication options include � I�19t1�Wo 3•- -'' ?:..' Ethernet,Wi-Fi,and cellular. Number of SunPower AC modules 85 Temperatu,e -22°F to {1401F(-30°C to+60'0)supported per P'v56 1-lumidity(maximum) 9596,non-condensing High-speed internet accessvia accessible Internet access router or switch 10()-2401 VAC(IN),SQ or 60117 Power. • 208 VAC(L-Lin 3-phase).60 Hz ; 'r 0 p i.�.a Yti;.• ZS-48.7 •. V inverters and meters • One channel of revenue-grade production etering kitcgrated Metering • Two channels cf,consumption metering ._.._—.—._—._................. ..._...._.._—__. _ -_.............. _.._..... Weight 5.5 lbs(2,5€cg) Ethernet i LAN(or optional`IRAN)pert Dimensions 11,8 x 8.0 x 42 in.(30.5 x 20.5 x 10.8 cm) PLC PLC for SunPower AC modules Enclosure rating UL90E Type 3( WI-F 802.11 bl,/n 2.4 GHz and 5 GHz ---- -...................i---._.........._._...-..-.._........_.....__........__._......_..._ ._...........---.-...-............ Cellular LTE Cat-M1/3(iiUMTS ti .. ice ll0(3ee IE((.802.1 5',4 MAC:2.4(.-;Hz ISMband Data Storage 60 days Customer site InoLN-tot we corn _...- - -..._.._................_.................---.—._._._............---...._............-....-............. .._.. Upgrades Auornatic firmware upgrades Partner site pvsm,gmt.us.sunco=rye r.com Browsers Firefoy,Saari,and Chrcme Mobile devices iPhone",iPacl',and Android' v Customer a r - Pp 1.Create a:count online at:monitor u_,.sunpoover.com. 2.On a mobile device,download the SunPovrer Monitoring Warranty 1C-year Limited Warranty app from,apple App Stores"or Google Piayt"store. 3.Sign in using account email and password. Certifications UL cUL,CE,UL 61010-1 and 2,FCC dart 15(Class Bim) 1 V C(U Ills LMM FCC 1D:YAW529027 E503346 536 R6VC t ,S U N ROW ER