Loading...
HomeMy WebLinkAbout25247-zFOPuM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT office of the Building Inspector Town Hall southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-26044 Date: 10/20/98 THIS CERTIFIES that the building ACCESSORY Location of Property: 1195 GOOSE CREEK LA SOUTHOLD (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 78 Block 8 Lot 8 Subdivision Filed Map No. __ Lot No. __ conforms substantially to the Application for Building Permit heretofore filed in this office dated OCTOBER 19, 1998 pursuant to which Building Permit No. 25247-Z dated OCTOBER 19, 1998 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is INSTALLATION OF A WOOD STOVE IN EXISTING ONE FAMILY DWELLING AS APPLIED FOR "AB BUILT. The certificate is issued to ARTHUR & MARCIA WEINBERG ' (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED N/A N/A N/A Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 25247 Z Date OCTOBER 19 98 Permission is hereby granted to: ARTHUR & MARCIA WEINBERG CUTCHOGUE,NY 11935 for : INSTALLATION OF A WOOD STOVE IN EXISTING ONE FAMILY DWELLING AS APPLIED FOR "AS BUILT" at premises located at 1195 County Tax Map No. 473889 Section 078 pursuant to application dated OCTOBER Building Inspector. GOOSE CREEK LA SOUTHOLD Block 0008 Lot No. 008 19 98 and approved by the Fee $ 35.00 Building/Inspecto~ ORIGINAL Rev. 2/19/98 BLDG. DEFT. _?OWN OF SOUTHOLD Form No. b TOWN OF soUTHOLD BUILDING DEPARTMENT TOWN HALL !.; APPLiCATiON FOR iiSR;iiSFi2CATE OF OCCUPANCY This application must be filled in by typewriter OR ink and submitted to the building inspector with the following: for new building or new use: 1. Final survey of .property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval froRIHealth Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and ~pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00. Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Buildin~ - $100.00 3. Copy of Certificate of Occupancy - , .25~. 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date . . New Construction ........... Old Or Pre-existing Building. ~ .............. Location of Property .... '.~.. '' ' House No. Street Hamlet N: ci .............. Omwer or Owners of Property ...... -. ' ............. P.% ." County Tax Map No I000, Section .......... Block ............. Lot ........ ; ........ Filed Map Lot ...... Subdivision ................................................................ Permit No..%53.4.7~ ........ Date Of Permit.l&/.l~/~ ....... Applicant 2kR.TliU~ R. MARCIA. WEIMBERC ..... Health Dept. Approval............ ............ .. Underwriters Approval ......................... Planning Board Approval ...... Request for: Temporary Certificate ........... Final Certicate ........... Fee Submitted: $ .... APPLICANT 24 Clearance Clearance Defiant Encore Clearance Chart Stove Clearance Unprotected Surfaces Protected Surfaces Stove Installed I Stove in Stove Installed Stove in Parallel to Wall Corner .~ Parallel to Wall Corner Side Rear Corners Side Rear Corners (A) 24-" (B) 31" (C) 24" (D) 8' (E) 15' (F) 8' No stove heat shields (610 mm) (790 mm) (610 mm) (200 mm) 080 mm) (200 mm) Topexit, rearstOVe (G) 24" (H) 19~ (1) 17~ ", (J) 8" (K) 11" (L) 7" and chimnod, connector (610 mm) (480 mm) (430 mm) f (200 mm) (280 mm) (180 mm) heat Rearexit, rearstove (M) 24" (N) 19" NA (P) 8" (Q) 11" NA heat shield onJy (610 mm) (480 mm) (200 mm) (280 mm) Chimney Connector Clearance All Installations All Installations No chimnqy connector heat shields (S) 24" (610mm) (S) 8" (200 mm) Chimrjey connector heat shields installed (S) 12" (300mm) (S) 4" (1O0mm) Clearance to Combustibles in Front of Stove All Installations (S) 48" (1220mm) l. A ceiling hear shield 24~ (610mm) in diameter and suspended 1" (25mm} from the ceiling, mmr surround the chimney connector in installations in which the chimney connector penetrates the ceiling. The chimney connector shield extends only to 28' (? 10mm) above the flue colllar. 2. The ceiling heat shield required when the chimney cormector shields are used should meet the wall protector. This will requite trimming the ceiling shield along the line of intersection with the wall protector. Defiant Encore Clearance Diagrams Unprotected Surfaces Stove Installed Stove in Parallel to Wall Corner Protected Surfaces Stove Installed Stove in Parallel to Wall Corner Top Exit Installations Rear Exit Installations NA E NA 28 Spe~ifica~ior~ Specifications Range of heat output ................................ 8,700-41,700 Btu's/hr.* Maximum Mat output ...................................... 47,000 Btu'dhr.*" Area heated*** ............................. Up to 1900 sq. fi. ( 115 sq. ut.) Fuel size/type ........................................ 18-20' (450.500 mm) logs Fuel capacity ......................................................... 40 lbs. { 18 kg.) Loading ....................................................................... Front or top Chimney connector ................................... 8" (200 mm} diameter Chimney flue size ...................................... 8" (200 mm) minimum Flue exit Fosition ........................................ R~ver~ible, top ot rear Primary air .................. Manually set, thermostatically maintained Secondary ait .......................................................... Self-regulating Ash handling system ....................................... Removable ash pan Glass panel ........................................... High.temperature ceramic Weight ............................................................... 350 Ib~./159 kg.) Width(leg-to-leg) .................................................. 27" (685 mm) l~pth (leg-to-leg) .................................................. 15" (380 mm) Height to top of flue collar: With regular legs ..................... 25-1/4" (640 mm) top exit ................................................ 26-I/2" (675 mm) rear exit With plinth ............................. 23-1/4" (590 mm) top exit ................................................ 24-1/2" (620mm) rear exit 7,3/8" 190 mm) [-- 27" (685 mm) -- (685 mm) Front elevation '5" (130 mm) 22-1/2" (570 mm) ~--- (390 mn*) 1,5' (380 mm) --~ *'5.1/4" (135 mm) Side elevation (460 mm) ~~ ~(83.114" (50 mm) 27' (690mm) To~ view 0CT-19-1998 11:01 TO: BROWN BROTHERS FAX NO. (2~) ~95 - 867O ~1~[0~ 1~0. (z12) ~93- ~ ~ / 212 49~ 55?4 P.01/0~ FAX NO.: FROM: DATI~: ~F~ O~ PACES ~TOT,COLTS~r~TO TInS COV]m S__m~.T) 0CT-19-1998 11:01 BROUN BROTHERS 212 493 55?4 P.02/03 Wail ChLam~ combus~bl¢ ma~rial the wall is cur away re provide r_hc required 18' (460 mm) clearance for the connector, The msuldng specs mus£ temaln empty. A flush-mounted She~r meral cover may be, used on one side only. If coverS must be use~. on .bgth sides, ench cover must be mounted on non.combustible spaccn at least 1" (25 mm) clear of r, he wall. Your local dealer or your local building inspector can provide details for other aDptoved me,,th, ods of passing a chimne~t co .n0ec- to,r thtougha combu, stlble wall in your area. InCanada, this ~ of insmllataon must conform to CAN/CSA- B365; Installation C. ode Mr Solid Fuel Burning Appli. anees and ~xtuipmenc. NOT~ Do not vent your De[iant Encore into a facto~.obmlt (~eamncc) fiteplace. These appliarc~s and their chimneys are specifically designed as a unit for use as fireplaces. It malt void the listing or be hazardous to adapt them {or any other use. DO NOT CONNECT A DEFIANT ENCORE TO ANY AIR DISTRIBUTION DUCt OR SYSTEM. Three other methods am also approved by thc NFl(A: ^ttem. en_doys am~mt~f heat radiates imm tim bottom * Using a =~rJon of double-wall ch mna¥ w th a'9;~C---- plat~. °~n_ _c~_~Z_?.._r~_ the floor beneath re~Lulms · ~vo Kinos or special protection. (230 mm) clearance to combusttbles ..... s' · · ' de a Hea b'o~ecaon ~s prowded by a Vermont Oasnng Placing a secn°n °re chinmey conncc r°r tnsi ...... ldKit art $0164 ventilated thimble, which in turn is separated from l~ortem, zaea, t ~n, ie , p, . :, .. . .--~.....:u~ ~.., ,o ~ ~n mra~ of fik"t,,las, i,~.ulatin,, S~ark ann eraser ~rptea~on ~s ptovmeo o¥ anoor ~.um.¥o,~,.,~ m ,. ,--~ , ~- o . --. o ,~romcwr, which may lac any non-combustible material. For a new heazth, we recommend a non-combusuhlc · Placing a section ofchinmey conoecror inside a section ofg' (230 mm) diameter, solid-insulated, factory- built chimney, with two inches {}fair space between thc chimney section and comhustibleL In Canada, ~ Canadian Standards A~sociation has established different, guide, lines. The illustmtionbelow, shows one method, m whmh all combustible material m floor protector such as 1/4' non-asbestos mineral board or its equivalent, or 24 gauge sheet metal. If carpeting is pte~s~nt, it must be removed beteore imt~lation of me floor protector. The floor protector may ~ covered with a non-combustible decorative material If de, aired. An appro~d wall pass-through [er Cn~d~, When using btlck,,tile, or stone for the decorative surface, individual pieces must he mortared so sparks cannot fall th, rough. , In the Ummd States, most installations wdl requite that the bottom heat shield be attached. Only when the stove is placed on a completely non-combustible surface, such as unpainted concrete over earth, may it be used without the heat shields, In Canada, installation of the Defiant tlncote is not permitted un]e~ the bottom heat shield is attached. Even with the bottom heat shield installed, you must alan usc a lb:or protector in both the United States and Canada. The required ~{imenslons for flour ptotectols vary sli~hWbetwecn the two countries: In tile United States, the floorprotector is required under the stove, and it must exrendar least 16 inches (not including the ash lip) from the front of the stove (labeled ~C" in accompanying illust~tion), and at lea~t 6 inches from the sides and rear (~D" and "E' in illustration). It must also extend under the chimney connector and 2 indaes to ~ither side ("F~ in illustration), For the Lq' (200 mm) connector used with the Defiant Encore, the protector must be a minimum of 12' (300 mm) wide, centemcl under the connector. To meet thee requirements, it floor protector must bo . at lcas~ 39' wide and'44' deep in the LJnited States. In Canada, a non-combustible floor protector is OCT-1B-1SgB 11:82 BROWN BROTHERS 212 493 5574 P.03/03 , ,- ~ 20lnstallatton__ A U.S. Canada A. 35' $9' (9~Ornm) g. 41" 4:P (ll70mm) C. lZ' 12' D. 6" 6' K 167 18' (~Omm) As a re. suit, such fireplace hearths can be a ~ci~ hazard and are considered a combustible floor. Keep in mind that many raJ~ed hearths will extend than the required clearance ftom the front of the heater when it is installed. In such eas~, sufficient floor protec- tion as described above must be added in front of thc hearth to satisfy the minimum floor protector requirement Re.q. uirvd floor protector dimensions for both top- and reap exiting stove. Combustible supporting timbers may lie beneath fireplace hen,ihs, raqairing additional flOOr protection. required un, der the stove as well, The floorptotector must extend 18 roches (460 mm) to the front (la~elcd "G" in accompanying illustration), :mci 6 inches (1SO mm) from the sides and rear ("D" and "IE" in illustration). TO meet these r~quircmcnts, a floor p~tector io Canade must be at least 39' (990 mm) w~de and 43' (1170 mm) deep. Floor protect on also must extend under the chimney connector and 2 inches to tit. her side ('cF" in i ustzafion), Fo~: the 8" (200 mm) conr)cctot used with the Defiant Encore, the protector must be a minimum of 12* (300 mm) wide, centered under the connector. An optional plinth can be used to raduce ~e D, dianr ]~ncore% heighrby 2~.(50 mm), However, a plinm installation must include the spec_iai Plinth H~t Shield ?acka~e and the Ddianr l~ncor¢ Rear Heat ah:eld plus standard non-combustible floo,rptotection that is 35' wide x 41' d(mp ~ 39' (990 mm) wi~ x 43' (I090 mm) ctcep in Canada ~ plus the requited 6 (150 mm) extending beyond thc stove to each sld, c and thc mar, and 16' (18' [4~0 mm] in Canada) in front of the stove. If the imtalladon is in thc Uni~ecl States and thc floor is completely non,combustible, the addi6onai floor protection and heat shields are not requited. The floor protection and heat shields arc always rcquimd in Canada. Floor Protection foe Fireplace l~ta|latlons Don't a~,sume that your fireplace hearth L~ completely non-combustible Many fireplace heat,tbs do not satisfy thc "complcre[y non-combustible" roqurrcmcnt becauro the brick or concrete in front of the ~rep!ace opening is ~upporred by heavy woc~ framing. Because hear passes,£hrou~gh brick, or concrete readily, it can ~sily pa~s through to mc wooo, from thc front of thc stove: 16' (410 mm) from thc front in the United States and 18' (460 mm) from the front in Canada. Hearth rugs do not satisfy the~equirement$ for floor protection. Fireplace imtallariom also have s~cia] clearance roquimmenu to thc side walls, side decorative trim, and fireplace mande. This information follows. Keep the .Stove a Sa. re Distance from Surrounding Matermls Both a stove.and it: chimney connector radiate heat in all directions when operating., and dangerous overheating of nearby combustible mater,als can ~ccur if they are too close to the hear. A sa~'e instal}ation requires that adeqoare ¢/e~o~e be maintainad between the hot stove and it~ connector and nearby combustibles. C~ar~e is the distance between either your stove (measured from the bottom edge of the stove's top plate) or chimney connector, and nearby walls, floor~, the ceiling, and any other fixed combustibla surface. Your stove has special olearanee requirements r, ha~ have been established aket careful reseagh and testing to UL and UI-C standards. These clearance requirements must be strictly observed. In'addition, furnishings and oghe~ combustible materials must be kep£ away from the stove as well. In ~neral, a distance o(48' (1220 mm) must be maintained between the stove and moveable combustible ireres such as drying g~othr, s, fumi£ure~ newspapers, firewood, erg, Keeping those clearance areas erupt3, assures that neaffoy sunCaces and objects will not overheat, TOTAL P.03 'FORM NO. 1 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL $OUTHOLD, N.Y. 11971 TEL,: 765-1803 .... BOARD OF HEALTH ...... 3 SETS OF PLANS ....... SURVEY .......... CHECK .......... SEPTIC FORM · NOTIFY CALL ................ MAIL TO: Disapproved a/c ..................................... ( ui ing Inspector) APPLICATION FOR BUILDING PERMIT 19?d Date ............ INSTRUCTIONS a. This application must be completely filled in by typewriter or in ink and submitted to the Building Inspector, with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streetf or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this appli. cation. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issued a Building Permit to the applicant. Such permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or .used in whol~ or in part for any purpose whatever until ~ Certificate of Occupancy shall have been granted b3~ the Building'fnspec{br. ' APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Towfi of Southold; .Suffolk Coun3?, New ~ork, and. other appl. i~a..ble Laws, Ordinances Regulations, for. the construction of buHdlngs, additions or aiteratmns, or for remo{ml or demollhon, as herein described. The applicant agrees to comply wit.h all app. licable laws, ordinances, buildin_.g, oedeT-,-,-,-,~eusing~.qp:~t_e, and regulations, and tc admit authorized insp. ectors on premises and m bufilding for necessary i: .(,~Fe~.c.t~~/...~___~... . ..... ~,.~q¢,' ~ t~ ~7/oe~et ~& ................... (S~fe~}' fil~p~l~h~ ~)~ame, if a corporation) State whether applicant is owner, lessee, agent, architect, engineer, gen~al co~,t~t~,. 8e$~,,'pinmber or builder. .... . . . ...... ' ...... ~ '. ....~'.. .......d ' ': ' ' ' ':' '~[?,'rL~,_~;?,f' '~ ............... · . ~.as on t]e tax rou It' applicant is a corporation, si§nature of duly authorized officer. (Name and title of co,orate officer) . ALL CONTRACTOR*S MUST BE SUFFOLK COUNTY LICENSED Builder's License No .......................... Plumber's License No ......................... Electrician's License No ' Other Trade's License No ...................... Location of land on which proposed work will be done~ ............................ ltouse Number Street ltamlet County Tax Map No. 1000 Section ..... .7.~. ......... Block .... ~. ............. Lot...~.-. Subdivision ..................................... Filed Map No ................ Lot ............... (Name) State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy· · ~..~. ~.t .~..~.~...~ .. b. Intended use and occupancy ...... ~... ~.~.~. ............................................... 3. Nature ofw v ch i ble): New Building ..... ' ..... Addition .......... Alteration .......... ork (check x hi applies ' Repair ............. Removal ........ Demolition ............. Other Work ............... i (Descriplion) 4 Estimated Cost ~! · (to be paid on filing this application) 5. If dwelling, number of dwelling u nits ............... Number of dwelling units on each floor ................ If garage, number of cars ...... , ............................................................... 6. If business, commercial or mixed accupancy, specify nature and extent &each type of use .................. 7. Dimensions of existing strUctures if any: Front ............... Rear .............. Depth ............ Height ............... Numt er of Stories ..................................................... Dimensions'of same strUcture wit t alterations or additions: Front Rear Depth ...................... Height ...................... Number of Stories ................... 8 Dimensions of entire new constru :tion: Front ' Rear Depth Height ............... Numk er of Stories ....................................................... 9. Sizeoflot: Front ...................... Rear ...................... Depth ..................... 10. Date of Purchase..; ........................... Name of Former Owner ............................ I 1 Zone or use district m which prer ises are situated 12. Docs proposed construction violate any zoning law, ordinance or regulation: · 13. Will lot be regraded',; .......... i .................. Will excess fill be removed from premises Yes No 14 Name of Owner 6fpremises ' Address Phone No Name of Architect Address Phone No Name of Contractor ' Address ' Phone No 15. Is this property located w~thin 300 feet of a tidal wetland? *Yes ..... No ..... *If yes, Southold Town Trustees Permit may be required. .. I PLOT DIAGRAM Locate clr:arly and distinctly all uildlngs, whether existing or proposed, and. indicate all set-back dimensions from property lines. Give street and block ~ ~mber or description according to deed, and show street names and indicate whether :nterior or corner lot. AP ,ROV D !$ NOTED 766-1802 9 AM TO FoCLO~ke INSPEC 1 FOUNDA~ON- FOR POURED 2. ROUGH - FRAMII 3, iNSULATION 4, FINAL - CONS? BE COMPLETE F 4 PM FOR THE ION8; KWO REQUIRED £RETE IG & PLUMBING IUCTION MUST tC.O. ALL CONSTRUCTIO;N SHALL MEET THE REQUIREMENTS OF THE NY, CONStrUCteD. · ENE. Y CODES NOT ~E~PO.SI"LE FOR DESIGN OR CONSTRUCTION ERRORS m 'FATE O~ N~W~YOI~I~ .... i ou v ..... ' (Name of individual signing Icontract) 5Dye named, i UNDERWRITERS CERTIFICATE REQUIRED If copper tubing is :used for water distributing system; piping shall be of types _Kor L oD~ UNDERWRITERS CERTIFICAFE REQUIRED being duly sworn, deposes and says that he is the applicant is the ........................................................................ ,,~ (Contractor agent , corporate officer , etc . ) smd owner or owners, and is duly au_th, om.ed to perf..otto or have performed the said work and to make and file this ~plication; that all statements containe~l m this applicatton are true to the best of his knowledge and belief; and that the ork will be performed in the manner s~: forth in the application filed therewith. ~om to before me this ...................... day of.. otary Public, .'~~e~...('f. ~ U.A,qc~AF1ET O. ~UlXOt!F%'J (Signature of applicant)