Loading...
HomeMy WebLinkAbout47542-Z �o�oS�fF01,f�oG� Town of Southold 4/17/2023 P.O.Box 1179 y iftr 53095 Main Rd Southold,New York 11971 L� � CERTIFICATE OF OCCUPANCY No: 44024 Date: 4/17/2023 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 140 Pike St.,Mattituck SCTM#: 473889 Sec/Block/Lot: 141.4-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/23/2021 pursuant to which Building Permit No. 47542 dated 3/14/2022 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations for a restaurant to existing building as applied for. (Pookaberry Cafe Inca The certificate is issued to 140 Pike St LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47542 12/28/2022 PLUMBERS CERTIFICATION DATED 4/3/2023 JoNe Naranjo A ize ignature o�SUFFet�- TOWN OF SOUTHOLD BUILDING DEPARTMENT H TOWN CLERK'S OFFICE o • SOUTHOLD, NY 0 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47542 Date: 3/14/2022 Permission is hereby granted to: Zahra, Charles PO BOX 1137 Mattituck, NY 11952 To: alter an existing spa to a new restaurant as applied for per SCHD (food services only) approval. At premises located at: 140 Pike St., Mattituck SCTM # 473889 Sec/Block/Lot# 141.4-5 Pursuant to application dated 2/23/2021 and approved by the Building Inspector. To expire on 9/13/2023. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $806.80 CO-COMMERCIAL $50.00 Total: $856.80 Buil ing or ho��oF so�TyQl 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(Q-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: 140 Pike St LLC Address: 140 Pike St city:Mattituck st: NY zip: 11952 Building Permit#: 47542 Section: 141 Block: 4 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Tucker Electric Inc License No: 4926ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor X Pool New X Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 17 Ceiling Fixtures 10 Bath Exhaust Fan 2 Service 3 ph Hot Water GeSX2 GFCI Recpt 15 Wall Fixtures 1 Smoke Detectors Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures 12 CO2 Detectors 2 Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO 1 Transfer Switch UC Lights g2' Dryer Recpt GaS Emergency StrobeHeat Detectors Disconnect Switches 17 4'LED Exit Fixtures 2 Sump Pump Other Equipment: 60W Transformers-5, 96W - 1, W/D, 100A Sub 32 Circuit/25 Used, 100A Sub 22 Circuit/ 13 Used, Walk-in Fridge Notes: Restaurant Renovation Inspector Signature: Date: December 28, 2022 N � � S.Devlin-Cert Electrical Compliance Form o��pF SQUT�o! Town Hall Annex 4 F) 11Tel h e(631)765-1802 54375 Main Road uf 1)765-9502 P.O.Box 1179 G •: �"j Southold,rlY11971-0959 'Q �© i 1 APR 03 2023 TOV"90F80 THOLD BU LDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: 0 -V 93- �D2� Building Permit No. I Owner: Ca (Please print) Plumber:' (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. C (P umbers S46!ffiatut Sworn to before me this day of , 20 Dayline Cintron NOTARY PUBLIC,STATE OF NEW YORK RQugifiio in Suff 016442186 Qualified in SufTolk County Commission Expires 1011112026 Notary Public, County qo�aoF sou'yo # f TOWN OF SOUTHOLD BUILDING DEPT. °�ycoorm e�' 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY- [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION - [ ] FIRE RESISTANT PENETRATION ELECTRICAL:(ROUGH) NA ELECTRICAL (FINAL) ] CODE VIOLATION ] PR C/ REMARKS: MlYla� na � a OA d sr do DATE 519 Z INSPECTOR (� u Of 50(/T,��l # # TOWN OF SOUTHOLD BUILDING DEPT. �ycou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL ( ] FIREPLACE & CHIMNEY [ ] F SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: .,00.-- -F0 C6 vl 00 IrAht lAl m, ;)�"I� 1)"/ --o DATE 11132!Y INSPECTOR [/ 1 OP SOUIyo� —---- ` 4 # # TOWN OF SOUTHOLD BUILDING DEPT. �1y000MV 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FI [ ] FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �wlo\wtov nod DATE SS ?/ INSPECTOR l # f TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ rXFIRAE LATION/CAULKING FRAMING /STRAPPING [ L FIREPLACE & CHIMNEY [ SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL RE ARKS: LZ- DATE I'Y K UO Zl/ INSPECTOR OF SOUTyO� L-t-7 S-4 Z # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) /td ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: en" DATE INSPECTOR pF SOUIyO� BUILDING TOWN OF SO�ITHOLD BUI G DEPT. courme�' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL(4^ot [ ] `FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Oh"'. CLQ/ pv"—� www %0.40v, I 'lWQd4-f, �lvi �lm, tit., Q .--e otic ro DATE INSPECTOR Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck, New York 11952 Fax 631-298-2651 condonengineeri ng.com June 13,2022 Mr. Mike Verity ® 9 Chief Building Inspector JUN 5 2022 Southold Town Building Department 53095 Route 25 TOgV"OF WN OF SO,, P.O. Box 1179 Southold, New York 11971 Re: Pookaberry Cafe-140 Pike Street in Mattituck Dear Mr. Verity: I inspected the plumbing in the new bathrooms and kitchen in the building.The plumbing was found to be free of any leaks and properly installed. To the best of my knowledge the plumbing was installed in accordance with New York State Building Code standards. If you have any questions, please call me at 631-298-1986. Yours truly, don, P.E. A � 3• ` cl N 051 Bunch, Connie From: Frank Raynor <frank.raynor@yahoo.com> Sent: Saturday, December 17, 2022 5:01 PM To: Bunch, Connie Subject: Pookaberry Cafe 1 r FT?'n 4 rj 1+c.Jr. D4 E ,rt Yr1Err r' 7f , 7 r Y LAM }�j I 1 ��_ _. _.�.. � �;, . �� . ____�_ • �aitr �� +�_ i `�� � �� _ J' �i 1/� t� ��� ;,,�{'r;0 r� � 4 r � ,� 'f' v :��- ..k '� _` �. . ' .� ��' r ...�' _ , . , , , . ,` � -`_�� y ` '� _� ���'��� �r�''� �_ w ,w1 • � Jm 4 1 . . . Sean Here are the corrections made at pookaberry Cafe. Pike Street, Mattituck NY Please let me know that you got the pictures. Thank you. Frank Raynor Tucker Electric Inc Po Box 1065 Cutchogue. NY 11935 631-478-2801 Sent from Yahoo Mail on Android ATTENTION: This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 5 Bunch, Connie From: Frank Raynor <frank.raynor@yahoo.com> Sent: Wednesday, December 28, 2022 8:44 AM To: Bunch, Connie Cc: MARCOART Subject: 220 GFCI BREAKER FOR DISHWASHER r� C�55- Im The photo is the 220 GFCI breaker for the dishwasher at the ookaberry Cafe at Mattituck pike Street Please let me know if you need any other photos. Please pass this photo to Sean the Electrical Inspector. Thank you Frank Raynor Tucker Electric Inc 631-478-2801 Sent from Yahoo Mail on Android ATTENTION: This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. i e e o ® • OEM FOUNDATION ------------ • e • a o VFW, ROUGH PLUMB MIG At Be owe@ Wit �r�S9 Fa .aJ • e D ® 9 � a 1 ull � I rl. ..' /i �� � i� � � _ ��9J� � �� 1�,�ral�O / I! SI, I/ Ir� f•1 /,l i • 9`0 SUFF�°k o TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town H&il Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.Southoldto3ynny.l7L Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D C E ERMIT NO. Building Inspector: DEC 7 2021 pplicationsand forms must be filled out in their-entirety.'Incomplete BUILDING DEPT. pplications will not be accepted.. Where the Applicant is not the owner,an TOWN OF SOUTHOLD wrier's.Authorization-form(Page 2)shall be completed.. ate: December 16, 2021 WNER(S):OF PROPERTY:' .; ame: SCTM#1000-_141-4-5 roject Address:170 Pike Street Mattitruck, NY hone#: Email: ailing Address: CONTACT PERSON Name:peter Marco MailingAddress:455 Schoolhouse Road, Cutcho ue 11935 Phone#: 332-2100149 Email: DESIGN PROFESSIONAL INFORMATION:'.. Name:Johyn J. Condon, PE Mailing Address:1755 Sigsbee Road Mattituck,_NY 11952__ Phone#:631-298-1986 Email:condoneng@optonline.net CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY•INFORMATION"-` :: ` ,,.•;. Existing use of property_CommercialIntended use of property:COmmerclal Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑ Check Box After Reading:-The owner/contractor/desigri'professional 1s responsible for-all drainage and,storm water issuesas provided.by Chapter 236 of the Town Code:APPLICATION IS HEREBY MADE to the Building Department for the issuance.of a,Building Permit pursuant to.the Building.Zone Ordinance of the Town of Southold,Suffolk,County;New York'and other applicabr le Laws,Ordinances oRegulations,for the construction of buildings, additions,alterations or for removal or demolition as herein describeil:The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary.inspections.False statements made herein are punishable as a Class A misdemeanor.pursuant to Section.210AS of the.New York State Penal Law. . Application Submitted By(print name):Peter Marco IRAuthorized Agent El Owner Signature of Applicant:. Date: becenfia STATE OF NEW YORK) SS: COUNTY OF ) Peter Marco being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. `��r,ttUtt�/ii Sworn before me this D. Fp e Iy day of � ,�il ,200� It _��Oa:�o� °•s o ry ubliC MD.01FO6241401t N icomm. y 23,203 ir. ` .QAC ' PROPERTY OWNER AUTHORIZATION ''�'�9�c•F0.`��` (Where the applicant is not the owner) residing at p,-30l01 ke Cs-nr"t do hereby authorize P�4C-t/— Q--kC C-n to apply on my behalf to the To n of Southold Building Department for approval as described herein. NJ /2- �2-o-Z 1 Owner's Signature Date "ho-Vl 'es zQ Print Owner's Name 2 Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck,New York 11952 Fax 631-298-2651 condoneng i neeri ng.com January 20, 2022 rc- JAN 2 0 2022 a Ms. Amanda Nunemaker Building Permits Examiner TOWN OF SOUTNOLD Southold Town Hall Building Department 53095 Route 25 P.O. Box 1179 Southold, New York 11971 Re: Pookaberry Cafe-140 Pike Street in Mattituck Dear Ms. Nunemaker: The following are our answers to your plan review letter: Item 4 -As part of the Health Department review for restaurants,the plans were also reviewed by the Waste Water Management department and they were provided copies of the approved septic system which is currently installed on the property. The septic system is designed to handle the waste from a 35 seat restaurant and an apartment with a square footage of between 601 and 1,200 square feet.The current design for the building has a 35 seat restaurant and 769 square foot apartment which is within the capacity of the septic system. Based on this the Waste Water Management department approved the plans which resulted in overall Health Department approval Item 6-The only area in the building where walls and ceiling will be opened is in the new kitchen area. A note has been added to the plan to assure that the existing insulation is not disturbed or removed. Item 10-The cellar has its main means of egress which is a stair to the first floor where there is a door to the exterior at the top of the stair and a second means of egress through a bilco door and steps at the rear of the cellar. If you have any questions, please call me at 631-298-1986. Yours truly, n, P. . VIII 4 �p .! a Mak 3F� iu� 1 2023 = .eat°`OIJMJood Establishment Inspectiobft@5,_--L,,-, rJ Ud6y�1§� Suffolk County Department of Health Services - Page 1 of 4 360 Yaphank Avenue Suite 2A Yaphank,NY 11980 Date: 03/31/2023 631-852-5999 www.suffolkcountyny.gov/health ' p Establishment Name Establishment Address City/State Zip Code Telephone POOKABERRY CAFE 140 PIKE ST MATTITUCK,NY 11952 Facility ID# Permit Holder Purpose of Inspection Inspection Result FA0011567 POOKABERRY CAFE INC `Premise/Facility Inspection Permit Issued Owner Owner Address Permit Restrictions Capacity POOKABERRY CAFE INC PO BOX 222, CUTCHOGUE NY 11935 seats Inspection Violations Comply By Date 01 01-PERSON IN CHARGE PRESENT,EMPLOYEES TRAINED,DEMONSTRATES 3/31/2023 KNOWLEDGE Violation Description/Inspector Comments: 760-1340.6-There shall be a designated person in charge of the food establishment who holds a valid food safety/food protection certificate issued by an authority approved by the Commissioner during all hours of operation.No food establishment shall employ a person in charge of its operation unless such person holds a valid food safety/food protection certificate issued by an authority approved by the Commissioner. In the case of an owner-operated establishment,the owner must be so certified. Recertification shall be required every three years. 1)THERE WAS NO ONE IN CHARGE OF THE OPERATION AT THE TIME OF THE INSPECTION WHO WAS IN POSSESSION OF A VALID FOOD SAFETY/FOOD PROTECTION CERTIFICATE ISSUED BY AN APPROVED AUTHORITY. 2)NOT ALL SHIFTS ARE MANAGED BY A PERSON WHO IS IN POSSESSION OF A VALID FOOD SAFETY/FOOD PROTECTION CERTIFICATE ISSUED BY AN APPROVED AUTHORITY IN THAT THERE WERE NO VALID FOOD MANAGER CERTIFICATES ON SITE AT THE TIME OF INSPECTION. —CORRECTIVE ACTIONS#1-2:EMPLOYEES TO ENROLL AND SUCCESSFULLY COMPLETE THE FOOD MANAGERS COURSE 3)THE OWNER/OPERATOR WAS NOT IN POSSESSION OF A VALID FOOD SAFETY/FOOD PROTECTION CERTIFICATE ISSUED BY AN APPROVED AUTHORITY. --CORRECTIVE ACTION:OWNER/OPERATOR TO ENROLL AND SUCCESSFULLY COMPLETE THE FOOD MANAGERS COURSE 06 06-PROPER HANDWASHING 3/31/2023 Violation.Description/Inspector Comments: 760-1354.1-Adequate hand washing facilities must be provided in or immediately adjacent to toilet rooms and in food preparation areas and food service areas,used only for hand washing,and located as to permit convenient and expeditious use. These must be kept clean and equipped with hot and cold running water dispensed with a mixing faucet at a temperature of at least 100oF(38oC),hand cleansing liquid or powdered soap in suitable dispensers,and approved sanitary towels or other approved hand drying devices. 1)THERE WAS NO LIQUID/POWDER SOAP AT BOTH OF THE TOILET ROOM HAND WASH SINKS. --CORRECTIVE ACTION:SUPPLY IMMEDIATELY Food Establishment Inspection Report Suffolk County Department of Health Services Page 2 of 4 360 Yaphank Avenue Suite 2A Yaphank,NY 11980 Date: 03/31/2023 631-852-5999 {� www.suffolkcountyny.gov/health x� Establishment Name Establishment Address City/State Zip Code Telephone POOKABERRY CAFE 140 PIKE ST MATTITUCK,NY 11952 Facility ID# Permit Holder Purpose of Inspection Inspection Result FA0011667 POOKABERRY CAFE INC Premise/Facility Inspection Permit Issued Owner Owner Address Permit Restrictions Capacity POOKABERRY CAFE INC PO BOX 222, CUTCHOGUE NY 11935 seats 44 44-WAREWASHING FACILITIES-MAINTAINED,PROPERLY USED,TEST STRIPS 4/14/2023 Violation Description/Inspector Comments: 760-1346.14.a-Dishwashing machines(spray type or immersion)shall be properly installed,operated in accordance with the machine's data plate and other manufacturer's instructions,and maintained in good repair. The flow pressure of spray type dishwashing machines shall not be less than 15 nor more than 25 pounds per square inch on the water line adjacent to the machine.Water pressure measuring devices shall display pressures in increments of 1 pound per square inch or less,shall be accurate to plus or minus 2 pounds per square inch,and maintained in good repair.A 6.4 millimeter or%inch Iron Pipe Size(IPS)valve shall be provided immediately upstream from the control valve to permit checking the flow pressure of the final rinse water. Rinse water shall be so protected by baffles,or other effective means,as to minimize the entry of wash water into the rinse water. 1)THE MECHANICAL DISHWASHER IN THE KITCHEN WAS NOT FUNCTIONING AT THE TIME OF INSPECTION. Food Establishment Inspection Report Suffolk County Department of Health Services ' - - Page 3 of 4 360 Yaphank Avenue Suite 2A Date: 03/31/2023 Yaphank,NY 11980 631-852-5999 www.suffolkcountyny.gov/health Establishment Name Establishment Address City/State Zip Code Telephone POOKABERRY CAFE 140 PIKE ST MATTITUCK,NY 11952 Facility ID# Permit Holder Purpose of Inspection Inspection Result FA0011667 POOKABERRY CAFE INC Premise/Facility Inspection Permit Issued Owner Owner Address Permit Restrictions Capacity POOKABERRY CAFE INC PO BOX 222, CUTCHOGUE NY 11935 seats —Overall Inspection Comments RE:DISHWASHER -THIS ESTABLISHMENT SHALL BE ISSUED WITH A PERMIT WITH A SINGLE USE RESTRICTION DUE TO DISHWASHER WAS NOT FUNCTIONING AT THE TIME OF INSPECTION. Establishment is built substantially according to approved plans except as noted below". Establishment may open once all food contact surfaces have been washed and sanitized. Your permit will arrive shortly by mail.This report acts as a temporary permit until then.Once it arrives,please post it in public view with at least 1 Food Safety Certificate. 'Establishment the employee toilet room was not built as shown on the layout. Reminder:Bare-hand contact with ready-to-eat foods,open display of foods,operating with an expired permit and operating without a food manager on duty is subject to legal action. Inspected By Michael Cromwell,San ID#963 Cooper Min/Max 963 used Inspection results are available online at https://eco.suffolkcountyny.gov/#/pal/search Risk Factors cited in consecutive inspections may result in enforcement action,including a possible hearing and fine. THE FOOD MANAGER'S COURSE IS AVAILABLE ONLINE IN ENGLISH,SPANISH AND CHINESE! To register for the Food Manager's course,please visit https://apps2.suffolkr-ountyny.gov/Health/FdOnline/default.aspx. Suffolk County FMC App and SIRF self-inspection app for mobile devices are available for download from Google Play and the Apple Store. All food service establishment operators are required to post the following advisory on all menus(including website menus)and menu boards located inside or outside of the establishment:"Before placing your order,please inform your server if a person in your party has a food allergy". College,public and private school food operations are exempt. Effective Jan.1,2020 all drinking straws and stirrers must be provided in food establishments by consumer request only,and must be made of biodegradeable(non-plastic)material. Plastic drinking straws and stirrers may continue to be provided by request to consumers with a disability or medical condition. Effective July 1,2021 the use of latex products is prohibited in all food establishments. Further information at https:Hsuffol kcou ntyny.gov/Departments/Health-Services/Pu blic-Health-Protection/Plastics-and-Latex-Laws Suffolk County Local Law 29-2009 amended Chapter 437(now Chapter 754)of the Suffolk County Code to prohibit"heating or ignition of an e-cigarette which creates a vapor"in all public places. The use of"E-CIGARETTES"IN ALL ESTABLISHMENTS WITH A SUFFOLK COUNTY FOOD PERMIT IS PROHIBITED,SUBJECT TO ALL PROVISIONS OF THE NY STATE CLEAN INDOOR AIR ACT AND SUFFOLK COUNTY LOCAL LAW. EMPLOYEE SICK POLICY WAS DISCUSSED DURING THE INSPECTION: Person in charge was reminded that all sick employees MUST be excluded from food service.No sick employee is permitted to return to work until they have been symptom-free for at least 24 hours;certain illnesses require that employees are tested prior to returning to work,even if symptom-free,or require further Department approval. Contact the Bureau of Public Health Protection for details. A log must be kept on-site documenting the exclusion of ill employees. Food Establishment Inspection Report Suffolk County Department of Health Services ' Page 4 of 4 360 Yaphank Avenue Suite 2A Date: 03/31/2023 Yaphank,NY 11980 631-852-5999 " www.suffolkcountyny.gov/health Establishment Name Establishment Address City/State Zip CodeTelephone POOKABERRY CAFE 140 PIKE ST MATTITUCK,NY 11952 Facility ID# Permit Holder Purpose of Inspection Inspection Result FA0011567 POOKABERRY CAFE INC Premise/Facility Inspection Permit Issued Owner Owner Address Permit Restrictions Capacity POOKABERRY CAFE INC PO BOX 222, CUTCHOGUE NY 11935 seats EE0000963-Michael Cromwell PETER MARCO PRESIDENT "The items noted above are violations of applicable laws,rules and regulations found during an inspection of the operation of the facilities in this establishment which must be corrected as indicated.Failure to comply may result in the initiation of legal action against this establishment as provided for in Articles 2 and 13 of the Suffolk County Sanitary Code including a hearing,possible suspension of your food operation,and/or the publication of the violation and fines." 5007 v5 STEVEN BELLONEL� GREGSON H.PIGOTT,MD,MPH SUFFOLK COUNTY EXECUTIVE ,h �� COMMISSIONER SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES Suffolk County Department of Health Services Bureau of Public Health Protection Plan Review Unit 360 Yaphank Ave,Suite 2A ° Yaphank, NY 11980 r NOTICE OF PLAN REVIEW CONSTRUCTION OR ALTERATION OF FOOD SERVICE ESTABLISHMENT Establishment Name Establishment Address Pookaberry Cafe 140 Pike St Mattituck, NY 11952 The Department has reviewed an application for construction/alteration of the above referenced establishment. It has been determined that the plans cannot be approved at this time. Please review the items listed below and submit the requested information. Should you have any questions, please reach out to the reviewer directly. Required Paperwork ® APPLICATION FOR PLAN REVIEW: - Surface finish of basement concrete? Must be smooth, non-porous and easily cleanable ® APPLICATION FORA PERMIT: - Corporate title of Peter Marco ® EQUIPMENT SPEC/CUT SHEETS: - Thermomix is not NSF approved commercial grade.What are you using it for?Sous Vide? ® FLAT LINE PLUMBING RISER DIAGRAM: - Steamtable and combi oven must be indirectly drained Additional Approvals Required ® SEWAGE SYSTEM REVIEW REQUIRED - Please contact the Suffolk County Department of Health Services' Office of Wastewater Management at (631)852-5700. Approval from the Office of Wastewater Management is required before your food service plans can be approved. ® SEWAGE SYSTEM- FINAL APPROVAL IS REQUIRED Final approval from the Suffolk County Department of Health Services' Office of Wastewater Management is required before a pre-operational inspection can be conducted. Contact the Office of Wastewater Management at (631)852-5700 with questions. Water Heater Requirements ® THE WATER HEATER YOU HAVE SPECIFIED IS INADEQUATE TO MEET THE DEMANDS OF THE ESTABLISHMENT Minimum required water heater: 51.5 gallon with 145580 BTU or equivalent. Sinks/Plumbing ® MOP SINK - A mop hook is required. Cut sheet for mop hook provided but 14B not on plan Refrigeration and Hot Holding ® INSUFFICIENT REFRIGERATION - A walk-in refrigerator is required Equipment, Prep Space and Storage Areas ® PREP SPACE - Insufficient number of prep tables available for the proposed menu Layout/Other ® Panini press for grill marking bread only. No cooking without a hood ® Vacuum sealing requires NYS scheduled process approval. Please contact me for the requirements. PLEASE NOTE. WHEN RESUBMITTING PLANS THAT CONTAIN MULTIPLE PAGES, ONLY THE REVISED PAGES ARE REQUIRED. APPLICATION REVIEWED BY Amanda McDonnell 11/8/2021 PHONE: (631)852-5842 E-mail: amanda.mcdonnell@suffolkcountyny.gov Rev. 12/20 Suffolk County Department of Health Services Bureau of Public Health Protection aEL 17 1021 c r Plan Review Unit 360 Yaphank Ave,Suite 2ATO vvl4 OF SuUTHOLD Yaphank, NY 11980 CERTIFICATE OF APPROVAL CONSTRUCTION OR ALTERATION OF FOOD SERVICE ESTABLISHMENT Approval is issued under the provisions of Article 13, Section 1304 of the Suffolk County Sanitary Code Establishment Name Establishment Address Pookaberry Cafe 140 Pike St Mattituck, NY 11952 The Following Conditions Apply • This approval does not constitute approval by any other state or local agency • This certificate is not a permit to operate a food service establishment.The operator must call the Department at 631-852-5873 to arrange an inspection of the completed construction prior to operation • The proposed construction is in conformity with the plans and specifications approved by the Department • Approval is based upon the application,plans and menu provided.Any changes require written approval from the Department of Health Services • This approval is valid for 2 years.Extensions may be granted upon written request to the Department prior to the expiration date • The applicant shall comply with the following amendments to the plans and specifications: 1. Provide corporate title on permit application Issued for the Commissioner of Health r��zda�?2c�a�ure?� Designated Representative 12/14/2021 I � BUILDING DEPARTMENT- Electrical Inspector ,`•��' Ory TOWN OF SOUTHOLD �OWn gneii(631) nex- 54375 Main Road - PO Box 1179 o APR 2 7 2022thold, New York 11971-0959 - - �, o Telep765 1802 FAX (631) 765-9502 aull_ ��, TOWN outholdtownny.aov seand(c�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: April 25, 2022 Company Name: Tucker Electric Inc. Electrician's Name: Frank Raynor Jr License No.: ME - 4926 Elec. email:frank.raynor@yahoo.com Elec. Phone No: 631-478-2801 01 request an email copy of Certificate of Compliance Elec. Address.: PO Box 1065, Cutchogue, NY 11935 JOB SITE INFORMATION (All Information Required) Name: Peter Marco (POOKABERRY CAFE INC) Address: 140 Pike St., Mattituck, NY 11952 (PO Box 222, Cutchogue, NY 11935) Cross Street: Westphalia Rd Phone No.: 332-210-0149 Bldg.Permit#: Lf-7 j Y ';L email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New resaurant installation of new electric in kitchen, 2 bathrooms, lighting and receptacles throughout Square Footage: Circle All That.Apply: Is job ready for inspection?: 0 YES ❑ NO Z Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES [V--] NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y ON Additional Information: Please contact me at 631-478-2801 with any questions.Thank You Frank Raynor PAYMENT DUE WITH APPLICATION 0 BUILDING DEPARTMENT- Electrical Inspector eo V'a4 G� l`, Ic (� �`� 1c TOWN OF SOUTHOLD ?; �- Town HInnex - 54375 Main Road _-PO Box 1179 - AP 2 "� 2629 � �P uthold, New York 11971-0959 Telephbne`(631) 765-1802 - FAX (631) 765-9502 „g �f - southoldtownny.gov seand@,southoldtownny.gov s APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Inforrriation Required) Date: April 25, 2022 Company Name: Tucker Electric.lnc. Electrician's Name: Frank Raynor Jr License No.: ME - 4926 Elec. email:frank.raynor@yahoo.com Elec. Phone No: 631-478-2801 DI request an email copy of Certificate of Compliance Elec. Address.: PO Box 1065, Cutchogue, NY 11935 JOB SITE INFORMATION (All Information Required) Name: Peter Marco (POOKABERRY CAFE INC) Address: 140 Pike St., Mattituck, NY 11952 (PO Box 222, Cutchogue, NY 11935) Cross Street: Westphalia Rd Phone No.: 332-210-0149 Bldg.Permit#: LJ-7 j email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New resaurant installation of new electric in kitchen, 2 bathrooms, lighting and receptacles throughout Square Footage': . Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑✓ Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES Fg/] NO Issued On Temp Information: (All information required) Service Size❑l PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: Please contact me at 631-478-2801 with any questions.Thank You Frank Raynor PAYMENT DUE WITH APPLICATION oL �f1c). PERMIT# Address: Switches f.� Outlets 11 f GFI's Surface Sconces HH s ( Z UC Lt Q Fans - Fridge HW Exhaust Oven W/D Smokes DW Mini Carbon I Micro Generator Combo 1 Cooktop Transfer AC t AH Hood Service Amps Have Used Special: ��) ��'e� �•�' Comments: 14, 414C l C-el ���,/ )4NY / r1 LL C6 � 12fs�ADoSAN ct T7El2 coVnCA, , l . ca ✓O TI4 N50 mIJCN vv s4t S � -ETt 2 M fli2C � rr�"r SUFFOLK COUNTY WATER AUTHORITY 624 Old Riverhead Road,Westhampton Beach, N.Y. 11978 (516)268-1034 FAX No. (516)288-7937 June 15, 1998 SLMLK COUN'T'Y DEPARTNIENT OF HEALTH COUNTY CENTER RIVERHEAD, NEW YORK 11901 Gentlemen: This is to certify that the Suffolk County Water Authority has installed Public Water Service at the following location: 140 Pike Street Mattituck, N.Y.11952 A water meter was installed on : May 22, 1998 a }ISL ! $ ; Very truly yours, SUFFOLK COUNTY MOM AUTHORITY f nald P. Blake Eastern Regional Manager RPB/cah 4 .:r �g�fFO(KCOG TOWN OF SOUTHOLD—FIRE MARSHAL J x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownn.go_v FIRE PROTECTION SYSTEM PERMIT Date Received APPLICATION For Office Use Only C E1°I E PERMIT NO. Building Inspector: ® `°I SUN 0 3 2022 Applications and forms,must be filled out in their entirety.Incomplete LDD applications will not be accepted.WORK IS NOT TO BE STARTED prior BUILDING DEPT. to the approval of plans and issuance of a'permit. TOWN OF SOUTHOLD Hasa building permit been obtained for this project?,Z Yes ❑No If yes,building permit# Date:5/28/2022 PROJECT INORMATION:, ProjectAddress:140 PIKE STREET SCTM# 1000-141 .-4-5 city:MATTITUCK zip:11952 CONTACT PERSON INFORMATION: Name: 0 �. Mailing Address: Phone#: Email: Preferred contact method(select one): ❑Phone ,Email CONTRACTOR INFORMATION: Name:ABT DESIGN & FIRE PROTECTION Contractor License#:111 Mailing Address:1724 CHURCH STREET HOLBROOK,_,NY 11741 63 Email:ABTFIRE@YAHOO.COM - Phone#: 1--878-4896_ ._.. . _..._... - SCOPE OF WORK: Occupancy Description: ❑Assembly I9 Business ❑Education ❑Factory/Industrial ❑Institutional ❑Mercantile ❑Residential ❑ Storage Description of work:INSTALLATION OF KITCHEN EXHAUST HOOD R New System ❑ Existing System Modification Sprinkler/Standpipe/Water Supply Fire Alarm/CO Detection Systems" Other Fire Protection Systems (Check all that apply) (Check all that apply) (Check all that apply) ❑NFPA 13,13D or 13R System ❑Manual ❑Automatic El Smoke Control ❑Standpipe ❑ Fire Pump ❑Protected Premises(local) ❑Wet or Dry Chemical/Clean ❑Supervising station Agent Number of sprinkler heads: ❑Central Station R Kitchen hood/exhaust ❑ Other Floor Area(sq. ft.): 1 1 8 Check Box After Reading: I,the undersigned,understand that the issuance of a permit for the type which is herein applied for is based on the agreement to conform to all regulations,and requirements.I further understand that non-compliance of said requirements,by myself or any officer or employee of the firm or individual listed as the applicant on this form,shall be cause for revocation of said permit.Upon revocation of said permit the applicant or any employee of the applicant shall be prohibited to.conduct such work for which this permit was issued.The reissuance of'a permit shall be based upon review of the circumstances leading to the revocation.Any false statement(s)made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the Penal Law pp y(p Authorized Agent ❑Owner Application Submitted B (print name).- D Company(if applicable): ABT DESIGN & FIRE PROTECTION Applicant Signature: FIRE PROTE ION SYST ERMIT APPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). • FIRE ALARM/CARBON MONOXIDE DETECTION SYSTEM SUBMITTAL GUIDELINES • FIRE SPRINKLER SYSTEM SUBMITTAL GUIDELINES • FIXED FIRE SUPPRESSION,HOOD&EXHAUST SYSTEMS SUBMITTAL GUIDELINES FEES A$250 permit fee is required for a non-residential permit.A$50 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testing/inspection shall be made by contacting the Town of Southold Building Department(631)765-1802. FOR OFFICE USE ONLY Amount Paid: j Check.No.: A/0sJ'� FM: Permit No.: , 7,�r Z Date: 7 ZZ Exp.Date: . �3 3 2 a�ASUFFocK��Gy2 TOWN OF SOUTHOLD—FIRE MARSHAL y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtowm.gov FIRE PROTECTION SYSTEM PERMIT Date Received APPLICATION 4f For Office Use Only PERMIT NO. C y L Building Inspector: Applications and forms must be filled out in their entirety.Incomplete JUN 0 3 2022 -DD applications will not be accepted.WORK IS NOT TO BE STARTED prior to the approval of plans and issuance of a permit. BUILDING DEPT. TOWN OF SOUTHOLD Hasa building permit been obtained for this project? Yes ❑No If yes,building permit# Date: PROJECT INORMATION: " ProjectAddress:140 PIKE STREET SCTM# 1000-141 .-4-5 city:MATTITUCK zip:11952 CONTACT PERSON INFORMATION: Name: Mailing Address: Phone#: Email: Preferred contact method(select one): ❑Phone Email CONTRACTOR INFORMATION: , Name:ABT DESIGN & FIRE PROTECTION I contractor license Mailing Address:1724 CHURCH STREET_ HOLBROOK, NY" 11741 Phone#,631-878-4896. _.,. _._ ._._ Emai1:ABTFIRE@YAHOO..COM.._ ..... . .. ... .. ._ SCOPE OF WORK: Occupancy Description: ❑Assembly ®Business ❑Education ❑Factory/Industrial ❑Institutional ❑Mercantile ❑Residential ❑ Storage Description of Work:INSTALLATION OF UL300 COMMERICAL KITCHEN FIXED EXTINGUISHING SYSTEM R New System ❑Existing System Modification Sprinkler/Standpipe/Water Supply Fire Alarm/CO Detection Systems Other Fire Protection Systems (Check all that apply) (Check all that apply). (Check"all that apply) ❑NFPA 13,13D or 13R System ❑Manual ❑Automatic ❑ Smoke Control ❑Standpipe ❑ Fire Pump ❑Protected Premises(local) ©Wet or Dry Chemical/Clean ❑Supervising station Agent Number of sprinkler heads: ❑Central Station Kitchen hood/exhaust ❑ Other Floor Area(sq. ft.): 1 �;Check Box After,Reading:, I,the:undersrgned,;unAerstand that the"►ssuance of a;perniif for the type whick is herein applied for is based the,agreejn to conform to all,regulations;and;requirements I further understand that,non-co►nphance!of said requirements;by.myself or auy officer or`;,' :employee of the firm or inclMdual hsted as the appkanfon this form;'shalhbecausef6r revocation ofsaid permit..Upon'revocathon of said,permit•the , apphcanf or any employee"ot,the applicaptshall.be prohibited to.conduct such work forwhich'this permit wa_s issued.The reissuance:of,a:permitshall ,'based upon review of.the circumstanees leading to the revocation:Anyfalse.statement(s)made.herein`ir!e'punishable as,a.Class A'inisdeaieanor pursuanf'.,` to Section'210.45`of the Penal Law Application Submitted By(print name): (� RAuthorized Agent DOwner Company(if applicable): ABT DESIGN & FIRE PROTECTION Applicant Signature: Date: FIRE PROTECT SYSTE E IT APPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). • FIRE ALARM/CARBON MONOXIDE DETECTION SYSTEM SUBMITTAL GUIDELINES a FIRE SPRINKLER SYSTEM SUBMITTAL GUIDELINES • FIXED FIRE SUPPRESSION,HOOD&EXHAUST SYSTEMS SUBMITTAL GUIDELINES FEES A$250 permit fee is required for a non-residential permit.A$50 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testing/inspection shall be made by contacting the Town of Southold Building Department(631)765-1802. FOROFFCEUSE ONLY; ; Amount Paid: a ,:. Check No.: 16,Sf jam' FAVI: Permit No.: Z Date: p Exp.Date: 2 tq(-q , 5- X15 Easton, James From: david maretsky <abtfire11 @gmail.com> Sent: Tuesday,June 7, 2022 7:34 AM To: Easton,James Subject: [SPAM] - Marcos/Pookaberry Cafe, 140 Pike St, Mattituck Good Morning, we recently sent to your office permit applications for the exhaust hood and AES system at the above location. We noticed that the AES plans we sent has an error, the exhaust hood shows (2) 12"x12"ducts on the hood, when there is only one 21'x10". Please note that on listed (Econ Aire) exhaust hoods, a single duct penetration is allowable on hoods up to 14 feet long. I will send you amended AES plans for that soon. Aside from that there are no other changes. Reach me here via email , or at 631 872 5982 if you have any questions during your plan review. Regards Dave Maretsky ABT Fire Protection ATTENTION: This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. i o�As°F Coo TOWN OF SOUTHOLD—FIRE MARSHAL s2 Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 oy�o as Telephone(631)..765-1802 Fax(631)765-9502 https://www.southoldtomm.gov FIRE PROTECTION SYSTEM PERMIT Date Received APPLICATION For Office Use Only ® E C E � �f v] E PERMIT NO._47542_ Building Inspector: 17 Applications and forms must be filled out in their entirety.Incomplete JUN 2022 applications will not be accepted.WORK IS NOT TO BE STARTED prior BUILDING DEPT. to the approval of plans and issuance of a permit. TOWN OF SOUTHOLD Has a building permit been obtained for this project? ®Yes ❑No If yes,building permit# Date:6-15-22 —A PROJECT INORMATION: Project Address:140 Pike Street SCTM# 1000- !- S city:Mattituck Zip:11952 CONTACT PERSON INFORMATION: Name:MARCO (owner) Mailing Address:140 PIKE STREET MATTITUCK, NY 11952 Phone#:332-210-0149 Email:marcoartnyc@gmail.com Preferred contact method(select one): ❑Phone (]Email CONTRACTOR INFORMATION: Name:GARLAND FIRE SYSTEMS INC. Contractor License#:12000230776 Mailing Address:33 TEC STREET HICKVILLE, NY 11801 Phone#:516-223-3189 Email:dwalter@gfsfire.com SCOPE OF WORK: Occupancy Description: ®Assembly ❑Business ❑Education ❑Factory/Industrial ❑Institutional ❑Mercantile ❑Residential ❑Storage Description of Work:PROVIDING FIRE ALARM SYSTEM TO MONITOR SPRINKLER &AES B New System ❑Existing System Modification Sprinkler/Standpipe/Water Supply ' Fire Alarm/CO Detection Systems Other Fire Protection Systems (Check all that apply) (Check all that apply) (Check all that apply) R NFPA 13,13D or 13R System BManual DAutomatic ❑ Smoke Control ❑Standpipe ❑Fire Pump ❑Protected Premises(local) ❑Wet or Dry Chemical/Clean ❑Supervising station Agent Number of sprinkler heads: ❑Central Station R Kitchen hood/exhaust ❑ Other Floor Area(sq.ft.): 1 ®Check Box After Reading: I,the undersigned,understand that the issuance of a permit for the type which is herein applied for is based on the agreement to conform to all regulations and requirements.I further understand that non-compliance of said requirements,by myself or any officer or employee of the firm or individual listed as the applicant on this form,shall be cause for revocation of said permit.Upon revocation of said permit the applicant or any employee of the applicant shall be prohibited to conduct such work for which this permit was issued.The reissuance of a permit shall be based upon review of the circumstances leading to the revocation.Any false statement(s)made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the Penal Law Application Submitted By(print name): DOUGLAS WALTER RAuthorized Agent ❑Owner Company(if applicable): GARLAND FIRE SYSTEMS Applicant Signator . Date: 6-15-22 FIRE PROTECTION SYSTEM PERMIT APPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). • FIRE ALARM/CARBON MONOXIDE DETECTION SYSTEM SUBMITTAL GUIDELINES • FIRE SPRINKLER SYSTEM SUBMITTAL GUIDELINES • FIXED FIRE SUPPRESSION,HOOD&EXHAUST SYSTEMS SUBMITTAL GUIDELINES FEES A$250 permit fee is required for a non-residential permit.A$50 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testinglinspection shall be made by contacting the Town of Southold Building Department(631)765-1802. FOR OFFICE USE ONLY Amount Paid: Q Check No.: 1330 FM: Permit No.: Date: Exp.DiA. 2 • Proposed Bar/ Restaurant Pookaberry Cafe 140 Pike Street • Mattituck, NY 11952 FIRE ALARM SYSTEM Equipment Cut Sheets And Battery Calculations FIRE ALARM SYSTEM SUBMISSION GFS GARLAND FIRE SYSTEMS • 33 Tec Street Hicksville, New York 11801 TEL: 516-223-3189 FAX: 516-223-3126 NYS LIC. # 12000203776 LIC. HOLDER: JOHN P. GARLAND J� • STANDEY1 STANDBY S( UPV•) SUPV. ALARM I ALARM UQ ANTITY DESCRIPTION MAKE MODEL CURRENT EXTENDED I CURRENT EXTENDED 1 BASE PANEL(64 POINT) EDWARDS VS-1 0.155000 0.155000 0.204000 0.204000 0 PRIMARY LOOP CIRCUIT(FULLY LOADED LOOP) EDWARDS 64 POINT CARD 0.055000 0.000000 0.125000 0.000000 0 REMOTE ANNUNCIATOR PANELS EDWARDS RLCD 0.098000 0.000000 0.113000 0.000000 1 DIALER EDWARDS SA-DACT 0.041000 0.041000 0.041000 0.041000 0 ETHERNET CARD EDWARDS SA-ETH 0.034000 0.000000 0.034000 0.000000 0 CLASS A CARD EDWARDS SA-CLA 0.003000 0.000000 0.060000 0.000000 1 INTELLIGENT PHOTOELECTRIC SMOKE DETECTOR EDWARDS KI-OSD 1 0.000051 0.000051 0.000068 0.000068 0 INTELLIGENT HEAT DETECTORS EDWARDS KI-HFS 0.000045 0.000000 0.000045 0.000000 1 MANUAL PULL STATION EDWARDS GSA-M270 0.000250 0.000250 0.000400 0.000400 0 INTELLIGENT DUCT SMOKE DETECTOR EDWARDS GSA-SD 0.000250 0.000000 0.000400 0.000000 0 CONTROL RELAY MODULE EDWARDS GSA-CR 0.000100 0.000000 0.000100 0.000000 3 (SINGLE)INPUT MODULE EDWARDS GSA-CTI 0.000250 0.000750 0.000400 0.001200 0 CONTROL SIGNAL MODULE EDWARDS GSA-CC1 0.000223 0.000000 0.000100 0.000000 1 INPUT(WATERFLOWITAMPER)MODULE EDWARDS GSA-WTM/CT2 0.000250 0.000250 0.000400 0.000400 1 WALL HORN/STROBE(95cd) EDWARDS EG LED SERIES 0.000000 0.000000 0.076000 0.076000 • 0 WALL STROBE ONLY(15cd) EDWARDS MGI-VM 0.000000 0.000000 0.055000 0.000000 1 CELLULAR DIALER NAPCO FIRE STARLINK 0.071000 0.071000 0.200000 0.200000 2 CARBON MONOXIDE DETECTOR YSTEM SENSO C01224T 0.020000 0.040000 0.040000 0.080000 1 VIBRATING BELL POTTER MBA-8-24 0.000000 0.000000 0.060000 0.060000 0 CURRENT SUBTOTAL 0.308301 0.663068 TIME MULTIPLIER(HOURS) X 24.000000 X 0.083333 7.399224 + 0.055256 MINIMUM AMP HOURS REQUIRED(SUBTOTAL) 7.454480 BACK UP BATTERIES PROVIDED 12 VOLT 4 AH EDWARDS 12V4A 12 VOLT 6.5 AH EDWARDS 12V6A5 2:...: .r.12,VOLT IO AH';; ; -. .. :. .. ..,:. . . "EDWARD S4 - 12V1 0& 12 VOLT 12 AH EDWARDS 12V1 2A 12 VOLT 17 AH EDWARDS 12V17A 12 VOLT 24 AH EDWARDS 12V24A 12 VOLT 40 AH EDWARDS 12V40A 12 VOLT 50 AH EDWARDS 12V50A • 140 PIKE STREET MATTITLICK,NY V� KU1 Small Building Fire Alarm Solutions Kiddc� Technology that saves lives ' Intelligent Fire Alarm Systems ���1 ���� ��� / , ���~� FDmnn mmumo Wi / nmnmx 0244 ' S30001 Overview ��ot ~^"^^[V|�VV Features K]ddebrand intelligent life safety systems offer the power of ° Auto-programming speeds installation time high-end intelligent processing inconfigurations that deliver ° Supports V-Suheaintelligent modules and detectors uncomplicated solutions for small tomid-sized applications.With ° Form Ocontacts for alarm and trouble, Form Afor supervisory intelligent detection,electronic addressing, automatic device mapping,option�Ethern�Oounnac��t�and afull line ofeaai�' ° B��mn|oadd�oo|ngw�houtomotiode�oomapping oonhguredoptionoanjuundmodu|eo.thmse flexible systems offer ° Optional Ethernet port monitoring versatility that benofitobuilding owners and contractors alike. service,programming,diagnostics and ovariety ofsystem reports ° Two pmguammub|eew�ohoav�thLEDs and ou�omlabeling J�m��� pnmidomoneO|oeeAurC|a�mBi�a||igontd*�oe ° 8 �G iehomni�m�m����mo �dUL |oop�hatauppoMauptoG4de�oeaddmooeo,ondtwoO|auo8 " ' NoUficatinnAppliance Circuits(4AOs).Optional Class Adevice 1971-compliant strobe synchronization wiring ieavailable with the use ofamodule. ° Supports GSA-REL releasing module for fire suppression The VS4provides one Class AorClass Bintelligent device ° Class BorClass Awiring loop that supports upto2OUdevice addresses. Loop controller ° Ground fault detection bymodule modules may boadded incombination toexpand totuuy�em ° Optional xm�'pn�000|Fio|dGemerBhdgeforint»dtma* capacity in25O'pointincrements tnuptu1.00Odevice addresses. to3rd party Building Management Systems VG4panels include four N/Csthat may bewired for either Class A ° Supports uptneight uehalaonunoiatom.8LCD. LED'onkK orClass Boperation. and graphic interface) The RZ/1G-2module adds even more capacity toVSinstallations ° Can use existing wiring for most retrofit applications byadding upto10conventional device circuits and two additional ° Upload/download remotely orlocally notification appliance circuits.This makes them ideal retrofit ° Optional USB module for local printingorprogramming using solutions that can accommodate new intelligent detectors, aowell the configuration utility onatechnician's laptop aoexisting conventional devices. ° Two-level maintenance alert reporting VGSeries supports owide range ofhigh-end features, including: ° Pre-alarm and alarm verification bypoint ° Intelligent modules,detectors,and bases ° Adjustable detector sensitivity ° GSA-REL Releasing Modules ° 4x20character backlit LCD display ° R'Soheoremote annunciators ° Optional earthquake hardening:seismic Importance Factor 1.5 ° Integrated Carbon Monoxide gas sensing with K|'OSOD ~ Standalone operation detectors including distinct audible signaling ° Transmission test frequency byhour ° Alarm ONcommand manually activates alarm condition U� Page of uu`A s*sEr K85005-0135 Application Kdde VS Series life safety systems are powerful intelligent solutions Flexibility built right in for small to mid-sized buildings.Advanced intelligent technology Two fully-programmable front panel switch/LED combinations provide delivers the benefits of flexible system installation,while clean and an added measure of flexibility.Their slide-in labels take the mystery easy-to-operate user interfaces make panel operation and system out of custom applications,and present a clean finished appearance. maintenance quick and intuitive. Perfect for retrofits The smart choice Kidde VS Series control panels are particularly well-suited to Electronic addressing eliminates the tedium of setting dipswitches, retrofit applications.All connections are made over standard wiring and automatic device mapping ensures that each device resides -no shielded cable required.This means that in most situations on the system at its correct location. Meanwhile,innovative pro- existing wiring can be used to upgrade a legacy control panel gramming allows the designer to customize the system to pre- to VS technology without the expense or disruption of rewiring cisely suit the needs of the building owner. the entire building.VS control panels also support the ingenious Reliability you can count on RZI16-2 zone module,which adds up to 16 conventional circuits The inherent fault-tolerant characteristics of Analog/Address- and two NACs.This combination easily accommodates new able Technology boosts the reliability of Kidde fire alarm systems. intelligent detection alongside existing conventional circuits, When combined with VS Series smoke and heat detectors,these making it an superior solution in the retrofit market. systems deliver a level of dependability not previously available Scalable IP and Cellular Communications • for small to mid-sized applications.All Kidde systems are built to The panel supports IP connectivity using the SA-ETH option card exacting reliability benchmarks and meet international standards for monitoring services by a supervising station to meet NFPA for quality, in addition to agency listings for dependability. 72 Chapter 26. The Ethernet card uses the FIBRO protocol to Clear-cut remote annunciation communicate with Sur-Gard System receivers(see page 5 for Remote annunciation is a strong suit of the VS Series fire alarm compatible receivers).Several popular third-parry IP/Cellular systems. Up to eight annunciators can be installed on a single communicators have been tested with the VS control panels and system.Compatible annunciators include a range of LED and LCD are compatibility listed to UL864.The IP/Cellular communicators models that provide zone or point annunciation,as well as com- meet NFPA72 2013 edition requirements for sole or secondary mon control capabilities.VS control panels also supports graphic transmission paths. Using IP/Cellular communicators can reduce annunciation with optional graphic annunciator interface modules. the cost of ownership by eliminating POTS lines. Please see Each interface provides common control and 32 LEDs. the VS control panel compatibility documentation part number 3102354-EN for a full list of compatible communicators. Signals with a difference A complete line of accessories VS Series NACs are configurable to fully support the advanced VS Series life safety systems are supported by a complete line of signaling technology of Kidde Genesis and Enhanced Integrity no- analog/addressable detectors,modules and related equipment. tification appliances.These devices offer precision synchronization Consult the Ordering Information section for details. of strobes to UL 1971 standards.For Genesis devices,enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. Programming and remote diagnostics Dimensions I iidde VS Series life safety systems are simple to set up,yet offer �'� (2) (3) (4) advanced programming features that put these small building pan- I*-02-'I D3-- D, els into a class of their own.The auto programming feature quickly 0.. '00 O *0 gets the panel operational using factory default settings. Basic zone 1° i °O O and point settings can be programmed through the front panel O O O interface,so the system is up and running in no time. ) o 0For more advanced system configuration and correlation groups D1 ) °'' D8 programming,VS Series systems interface to a PC running compat- ible VS-CU software.This option offers full system configuration in ® - the familiar Windows®operating environment.Connection is made 4 to a laptop through the panel's optional RS-232 communications port,which can also be used to connect a system printer. Ds Among the many innovative features of VS Series control panels is �DS� °09►I D9W the optional network card.This module provides a standard 10/100 (1)Surface Mounting Holes (3)Backbox with Door Attached Base T Ethernet®network connection that permits access to the (2)Semi-flush mounting Holes (4)Backbox with door and trim kit attached. control panel from any remote location with the correct communica- tions protocols.The connection can be used to download to the Panel dimensions,in(cm) panel from the VS-CU,or upload and view system reports using the Model 131• tD2133 D4 os• D6 D7 Ds D9 VS,-CU. VS4 28.0 .0 22.0 15.75 10.25 4.9 30.1 2.7 (71.1) 2.8) (55.8) (40.0) (26.0) (12.4) (/6.4) (6.8) Available system reports include:Correlation groups, Device details, VS1 21.5 .5 15.5 14.25 10.25 4.9 23.6 2.7 (54.6) 9.0) (39.4) (36.2) (26.0) (12.4) (59.9) (6.8) Device maintenance, History, Internal status, System configuration, System status,Walk test, Dialer,and CO runtime. "Add 1-1/2 in.(3.81 cm)to D1 and D5 dimensions for trim kit The trim kit provides 0.75 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. Page 2 of 8 D A;- 7- K85005-0135 Plc': to t,e ..-v` ca:.......,,,i) c€s€fix u4s. Issue 2.0 System Layout VS4 Any combination of two single-or dual device loop modules --------------------------------------- soma -- I. i Standard Loop:250 points(one expansion slot) V-SLC2-2 Expander,Loop 9 of 2:250 points Up to 125 sensors and 125 modules per loop......... (one expansion slot) flp . JIM �='°., �i,�-,a.., ,�c,`� Vic::. �• u--SLC2-a 250 paints(crie expansion slot} V-SLC2-2 Expander,Loop 2 of 2:250 points ,o to 20,000 feet of wiringper loop__ Four Class B or two optional Class A NACs Four Class B or two optional Cfass A NACs 11wOptional 10A or 6.5 A Booster Ff Ethernet(SA-ETH)' DACT/Dialer(SA-DACT) Up to eight remote annunciators RS-232(SA-232 or SA-USB)**7:-FSixteen Conventional IDCs, Relays:Two Form C,one Form A "1 v two additional NACs with RZI16-2 module .•(iKidde 3 Each VS4 panel has room for up to two device loop controller modules in any combination of single or PanelLayout dual 250-device loops.VS4 comes with one loop _ that supports up to 125 detectors and 125 modules. 4- -008 n 0 VS1 2 s t' ® 8 i 1= Loop supports up to 64 intelligent devices of any type. — 8 10 �. . Up to 20,000 feet of wiring. = 11 ° ,•o .. ,F F 1 12 t r. y ,r o - 13 Two Class B or two optional Class A NACs isoVR Optional 10 A or 6.5 A Booster Power Supply o 61 1 Transformer ) 2 Main AC wiring block&fuse holder f Up to eight remote annunciators ) 3 RS-232 card connector(J3) Ethernet(SA-ETH)* 4 Dialer card connection(J8) i. DACT/Dialer(SA-DACT) 5 Ethernet card connector(Ji) d 6 Main circuit board RS-232(SA-232 or SA-USB)** 7 Panel backbox enclosure Relays:Two Form C,one Form A 8 Operator interface Sixteen Conventional IDCs, 9 SLC card connector(J7) !. two additional NACs with 10 Class A card connector(J2) �. RZ116-2 module 11 Tie wrap mounts Each VS1 panel ships with one device loop con- 12 LED expander connector(J6) troller that supports 64 devices of any type.This 13 Standby batteries panel's device capacity cannot be expanded. i *SA-ETH supports:(1)remote connectivity for diagnostics&programming,(2)Central station monitoring to Sur-Gard IP Receivers. —RS-232 supports:(1)Printer,(2)Programming Interface,(3)Use of Field Server Bridge(SA-FSB)for 3rd party Building Management Systems interface. Page 3 of s K85005-0135 No,i >.. <.,..c';n, i:i.:zo:latioa�p.ael Issue 2.0 Wiring & Configuration Device loop Auxiliary&smoke power outputs(TB3) The system provides one device loop circuit with a total capacity The control panel provides two auxiliary power TB3 of 125 detectors and 125 module addresses.The loop circuit is outputs that can be used for powering ancillary (2) supervised for opens,shorts,and grounds. equipment such as remote annunciators and two No (1) wire smoke detectors. Aux 2 can be software � NO Circuit VS4 VS1 selected to operate continuously.The circuit is specifications supervised for shorts and grounds. Device loops One Class B or A One Class B or A loop, (2) 0­11NO loop,supporting 125 supporting 64 devices of Circuit specifications 0 detectors and 125 any kind. Circuit voltage 21.9 to 28.3 V modules.Expandable to rangeNC four loops. Resettable circuit 24 VDC nominal at 500 mA (3) ��:Z Communication Maximum 20 V peak-to-peak NO (Aux power 2) line voltage Continuous circuit 24 VDC nominal at 500 mA. Circuit current 0.5 A max (Aux power 1) Use this circuit for powering Circuit 660 total,0.5 NF,max two-wire smoke detectors. 0 impedance (4) Isolators 64 maximum Note:Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that 0 Signal Supported on a system-wide basis(all device loops) amount. Synchronization when using an addressable notification appliance (1)Trouble circuit(NAC)module and Genesis or Enhanced Integrity notification appliances. (2)Supervisory Alarm,trouble,and supervisory relay(TB3) (3)Alarm Gass B wiring Class A wiring The trouble relay is normally-open, held closed,and opens on any trouble event or when the (4)Smoke/Aux m m panel is de-energized.The supervisory relay is SLC A +� Data SLC A +� normally-open,and closes on any supervisory SLC B +m + + SLC B + + + event.The alarm relay changes over on any Loop Loop Loop Loop alarm event. Loop card davlce device Loop card Data Line device device Relay specifications Alarm I Trouble Supervisory Notification appliance circuits(11`1132) Type Form C Form A VS4 control panels come equipped with four notification appliance Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive circuits.VS1 control panels come with two NACs. Each circuit can Relay circuits can only be connected to power-limited sources. be individually configured for continuous,temporal,synchronized, and coded output. Specifications ! VS4 VS1 Annunciator loop(TB4) Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A The control panel provides a connection for up to eight serially with SA-CLA module driven and supervised remote annunciators. Voltage 24 VFWR Current 6.0 A total,2.5 A max. 3.75 A total,2.5 A max. Circuit specifications per circuit at 120/230 per circuit at 120/230 Device loops Class B(Style 1)or Class A(Style 2) VAC 60 Hz. VAC 60 Hz. Circuit voltage 2.55 V 5.0 A total,2.5 A max. 3.0 A total,2.5 A max. Circuit current 30 mA max per circuit at 230 VAC per circuit at 230 VAC Circuit Up to 8 annunciators or 4000 feet S 50 Hz. 50 Hz. impedance Impedance 26 C total,0.35 pF max EOLR 15 K O,1/2 W Synchronization Supported system-wide Class B Class A Channell Channe12 Channell Channe12 Gass 8wiring ClassAwiring + — + — + — + — NAC7- NACI- o NACI+ + + 0 NACI+ + + & IS TB4 & & TB4 m �� + + EDLR 0 NAC2- + + Annunciator Annunciator 0 NAc2+ 0 NAC2+ - CHI(+)IN CHI(+)IN TO Tae CHI(—)IN CHI(—)IN 0 NAC3 + + 0 NAC3+ - - + NAC4- + + EOLR - " CH2(+)IN CH2(+)IN NAc4+ a+ CH2(—)IN CH2(—)IN Tee Tee Marking indicates output signal polarity when the circuit is active.Polarity reverses when the circuit is not active.Wire notification appliances accordingly.Notification appliance polarity shown in active state. Page 4 of s ",,. i; w._ K35005-0135 ©t's hp purposes. Issue 2.0 Option Cards Kidde VS Series panels are supported by a complete line of mod- RZ116-2 Remote Zone Interface Module ules and related equipment that enhance performance and extend PPf1'.2 system capabilities.Option cards plug directly into the control T panel main circuit board or are connected to it with a ribbon cable. After installation,terminals remain accessible.The cabinet pro- vides ample room for wire routing, keeping wiring neat at all times. :JeiaA m3'11..N. Single and Dual Loop Controller Cards The V-SLC2-1 is a single loop controller card that can be used The RZI16-2 Addressable Remote Zone Interface Module is an with the VS1 as a replacement for the standard 64-point loop, or addressable device that provides connections for sixteen Class B with the VS4 as a 250-point expansion module. Initiating Device Circuits and two Class B Supervised Output The V-SLC2-2 is a 500-point dual loop controller card for the VS4 Circuits.The inputs and outputs can be configured individually for that provides two IDC circuits,each with 125 detector addresses several device types. and 125 module addresses. The RZI16-2 requires 18 consecutive addresses on the Signaling Line Circuit(SLC).Addresses are assigned electronically.There are Specifications V-SLC2-1 V-SLC2-2 no address switches to set. VS4:one loop,250 VS4:two loops, device addresses 500 device The RZI16-2 incorporates two 8-segment DIP switches that are Device Addresses VS1:64 addresses addresses used to select the Alarm or Supervisory default device type for Wiring Class B or Class A each of the 16 IDC circuits.The module also includes one 4-seg- Operating Voltage 24 VDC ment DIP switch used to select the default Relay or NAC output Operating Current Standby:55 mA Standby:45 mA device type.Device types other than the default are accomplished (fully loaded loop) Alarm:80 mA Alarm:70 mA through programming. Note:These ratings do not include the use of two-wire smoke modules. RZ116-2 Specifications Communication Line Voltage Max.20.6 V peak-to-peak 24VVoltage Terminal Rating 12 to 18 AWG(0.75 to 2.5 mmg Sup Aux nominal: 24 VDC Circuit Current 0.5 A max. Supervisory current: 250 mA at 24 VDC nominal Alarm current: 1000 mA Max total loop resistance 66.0 24V/Aux minimum: 18.4 VDC Max total loop capacitance 0.5 uF 24V/Aux maximum: 26.4 VDC 64 isolators maximum per loop NAC1,NAC2 nominal: 24 VDC Isolators (total both isolator bases and modules) Current Ground Fault Impedance 0 to 5 kQ Standby current 32 to 120°F(0 to 49°C) for 4.7 k EOL(U.S.) 4.8 mA/circuit Operating Environment 0 to 93%noncondensing at 90°F(32°C) Standby current for 3.9 k EOL(Canada) 5.7 mA/circuit Alarm current at nominal voltage 31.1 mA/circuit SA-ETH Ethernet Interface Card/IP Communicator Relay outputs The SA-ETH card provides a standard Quantity 2 SA-ETH wiring 10/100 Base T Ethernet network Type Rating(pilot duty) Programmable 24 VDC at 2.5 A T°`°""�"°" "e"'°"` Input circuit wiring 25 Q per wire Network cable connection for connecting to an intranet, resistance a local network,or the Internet.The card Initiating device circuits 1 supports IP connectivity for monitoring Quantity 16 oH services by a supervising station to meet EOL resistor 4.7 kQ(U.S.);3.9 kQ Canada NFPA 72 Chapter 26. The Ethernet card Zone voltage 22.78 V for 4.7 kQ(U.S.) uses the FIBRO protocol to communicate 22.08 V for 3.9 1<0(Canada) with Sur-Gard System receivers(see Alarm current 31.1 mA/channel at nominal voltage Eftmet Lard Alarm impedance range <680.0 below).The card can be used to download configuration programming from the VS-CU Trouble impedance range >5.55 kQ to the panel. Supervised output circuits EOL resistor 15 kfl The Ethernet card is installed on the plastic assembly and Quantity 2 connects to the main circuit board via a ribbon cable. Short circuit detection <2.6 kf) Open circuit detection >61.9 kfl SA-ETH specifications Contact ratings 24 VDC at 2.5 A(5 A for two NACs) Ethernet 10/100 Base-T Compatible cabinets MFC-A,VS4,APS Operating environment Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F(32°C) Compatible Sur-Gard Receivers SG-System I,II,III,IV and 5 Page 5 of 8 7 =, s , .= K85005-0135 Mot ?o tie, ;,u-. , ;r-'7=;, 'z,;zrsal; ourposrs. Issue 2.0 SA-DACT Dialer SA-232 RS-232 interface The SA-DACT provides communications between the control The SA-232 card provides an RS-232 in- sA-232 wiring GNOpanel and the central station over a telephone lines stem. It terface with VS panels. It can be used for TXD(white aewick re) P P Y P TxD(venae ire) transmits system status changes(events)to a compatible digital connecting a printer to the control panel RXD(red wire) alarm communicator receiver over the public switched telephone to print system events.The card also FF network.The dialer is capable of single,dual,or split reporting can be used for connecting a computer ®® of events to two different account and telephone numbers.The to download a configuration program modem feature of the SA-DACT can also be used for uploading from the VS-CU to the control panel. and downloading panel configuration, history,and current status The RS-232 card is installed on the plas- to a PC running the VS-CU. tic assembly and connects to the main circuit board via a ribbon SA-PACT one line1 The dialer phone lines connect cable. wiring LHMTo wall to connectors on the dialer's main hon�Hne2 phone jack circuit board.Phone line 1 con- SA-232 specifications Phone cablesnects to connector J4 and phone Operating voltage Standard EIA-232 (supplied) RJ311)acks line 2 connects to connector J1. Terminal rating 12 to 18 AWG(0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120oF(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F(32°C) '•°°Q o "anap, , CID] a� The SA-DACT queues mes- SA-CLA Class A Module(VS1 only) ❑(u�_®,e°� sages and transmits them The SA-CLA card provides Class A capability for NAC wiring. °° based on priority(alarm, Its terminal block provides the wiring connection for NAC return , El o•"❑o° supervisory,trouble,and wiring.The card is required for annunciator Class A wiring even 09° .9 ❑ monitor).Activations are trans- though this wiring does not return to the SA-CLA card.The SA- mitted before restorations. CLA is compatible with VS1 control panels only.VS4 panels are The SA-DACT is installed on the plastic assembly and connects to Class A Ready.The SA-CLA is installed directly to the control the main circuit board via a ribbon cable. panel circuit board using its plastic standoffs and plug connection. SA-DACT specifications SA-CLA specifications Phone line type One or two loop-start lines on a public, Operating voltage 24 VFWR switched network Operating current 3.75 A FWR total at 120/230 VAC 60 Hz Phone line connector RJ-31/38X(C31/38X) 3.0 A FWR total at 230 VAC 50 Hz Communication formats Contact ID(SIA DC-05) 2.5 A max per circuit Operating environment Circuit impedance 26 ohms,0.35uF Temperature 32 to 120°F(0 to 49°C) Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) Humidity 0 to 93%RH,noncondensing at 90°F Operating environment (32°C) Temperature 32 to 120oF(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90oF Compatible DACRs (32°C) Receiver Models Formats Ademco 685 Contact ID FBII CP220 Contact ID D16L-VS LED Display Expander(VS4 only) Osborne-Hoffman OH 2000 Contact ID The D1 6L-VS LED Display Expanders provide LED Bosch D6600 Contact ID annunciation for up to 16 zones. It provides two LEDs Silent Knight 9800 Contact ID for each zone.Two D1 6L-VS LED display expanders • Sur-Gard SG-MLR1,MLR2 Contact ID can be installed in each VS4 panel. The SA-USB Interface Card The SA-USB Interface Card provides a USB connection to a (3) (4) supported printer or a connection to a PC.The card can be o�za e g p Zone d0 used for connecting a printer to the control panel to print system (2) o� 0L 0[ �1 gn events.The card can also be used for uploading and downloading a® 0 °o® o[� panel configuration, history,and current status to a PC running the owl o� � 8� configuration utility(CU). °® o� O $� 8 aim SA-USB Specifications °off o6 °o® °o ?° Operating voltage 24VDC (1)LED 1 Current Standby/Alarm 13 mA,max 20mA (e) (2)LED 2 Universal Serial Bus 1 USB Type A-host port J3(printer connection) (3)LED Expander 1 (USB)ports 1 USB Type B-device port J4(CU connection) Supported Printer PT-1S (5)LED Expander 2 Printer communication (5)and trouble zone speed 9600 baud and trouble zone LEDs Operating environment Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing Page 6 of 6 . ?s�1'A a= L j K85005-0135 Not to ire a--euw �: 7< ii $IC"1 purpoaes. Issue 2.0 Specifications VS1 VS4 Device loops 1 loop Class B or Class A(Styles 4,6,7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 modules) detectors and 125 modules max.).Addresses 1 to 125 are Maximum T-taps:63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop:124 Notification appliance 2 Class B(Style n Class A(Style Z)optional 4 Class B(Style Y)or 2 Class A(Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max,per circuit 2.5 A FWR each max.per circuit Primary power 120 VAC,60 Hz, 1.3 A max. 120 VAC,60 Hz,2.0 A max. 230 VAC,50-60 Hz,0.62 A max. 230 VAC,50-60 Hz,0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA • Input zones 16 max. 32 max. Remote annunciator 8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B Data line length:4,000 ft.(1,219 m) Data line length:4,000 ft.(1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1:500 mA,24 VDC circuit Aux power 2:500 mA,24 VDC(1 A possible if you reduce total available NAC power by 500 mA) Output:28.3 to 21.9 VDC,special application Note.For a list of compatible devices,see the VS1 and VS4 Series Compatibility List(P/N 3102354-EN) Loop circuit Maximum loop resistance:66 n Maximum loop capacitance:0.5 pF Communication line voltage:Maximum 20.6 V peak-to-peak Operating current(fully loaded loop)Stand by:55 mA/45 mA Alarm:125 mA/115 mA(not including two-wire smoke modules) Circuit current:0.5 A max.Style 4,6,and 7 wiring Max.resistance between isolators:Limited only by overall wire run lengths 64 isolators maximum per loop(total both isolator bases and modules) Batteries Type:Sealed lead acid Voltage:24 VDC Charging current:2.47 A max.Amp hour capacity:26 Ah Standby operation:24 hour or 60 hour Placement:Up to two 10 Ah batteries will fit in the VS1 control panel cabinet and two 18 Ah batteries will fit in the VS4 control panel cabinet.If larger batteries are required,use a battery cabinet. SA-DACT dialer Phone line type:One or two loop-start lines on a public,switched network Phone line connector:RJ-31/38X(C31/38X) Communication formats:Contact ID(SIA DC-05) Operating current Standby/Alarm:41 mA Max.: 100 mA FCC registration number:GESAL01 BSADACT Industry Canada Registration number:3944A-SADACT Ringer equivalence number:0.1 B Ground fault impedance 0 to 5 kQ Alarm contact Form C N.O.24 VDC at 1 A(resistive load) Trouble contact Form C 24 VDC at 1 A(resistive load) Supervisory contact Form A N.O.24 VDC at 1 A(resistive load) Environmental Temperature:0 to 49°C(32 to 120°F)Relative humidity:0 to 93%noncondensing Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm� Page 7 of 8 ,.4 r: :I E E T K35005-0135 ,tc`tv t>v , �_z .cr icy.+ai:aflr.n pmposas. issue2.0 - _ Ordering Information Part_ 'Description. til0 VS4 Fire Alarm Systems Kidde VS4-G Four loop system with one 250-point loop installed.110v,dray door. VS4-G-2 Four loop system with one 250-point loop installed.230v,gray door. VS4-G-2-PG Four loop system with one 250-point loop installed.230v,gray door,Portuguese. Technology that saves lives VS4-G-2-SP Four loop system with one 250-point loop installed.230v,gray door,Spanish. VS4-GC Four loop sy stem,one 250-point loop installed.119y,gra door,LED strips,Canada. Contact us VS4-GD Four loop system,one 250-point loop installed.11 Ov,gray door,with dialer. Phone: 888.244.9979(Option 4) VS4-GF Four loop system,one 250-point loop.110v,gray door,LED strips,French Canada. Email: kidde.fire@carriercom VS4-G-PG Four loop system with one 250-point loop installed. 110v,gray door,Portuguese. Website: kidde-esfire.com VS4-G-SP Four loop system with one 250-point loop installed. 110v,gray door,Spanish. VS4-R Four loop system with one 250-point loop installed. 110v,red door. 89855e Tois a Carrier brand. VS4-R-2 Four loop system with one 250-point loop installed.230v,red door. 89wn Center Pkwy, Bradenton,FL 34202 VS4-RD Four loop system,one 250-point loop installed.11 Ov,red door,with dialer. SA-TRIM2 VS4 Flush mount trim,black. 02021 Carrier _ .. . All Rights Reserved. VSi Fire Alarm Systems VS1-G One loop system with one 64-point loop installed.110v,gray door. VS1-G-2 One loop system with one 64-point loop installed.230v,gray door. VS1-G-2-PG One loop system with one 64-point loop installed.230v,gray door,Portuguese. VS1-G-2-SP One loop system with one 64-point loop installed.230v,gray door,Spanish. VS1-GD One loop system,one 64-point loop installed. 11 Ov,gray door,with dialer. VSi-GL One loop system,one 64-point loop installed. 11 Ov,gray door,English Canada. VS1-GL-F One loop system,one 64-point loop installed. 110v,gray door,French Canada. VS1-G-PG One loop system with one 64-point loop installed.110v,gray door,Portuguese. V_S1-G-SP One loop system with one 64-point loop installed.110v,gray door,Spanish. VS1-R One loop system with one 64-point loop installed.110v,red door. VS1-R-2 One loop system with one 64-point loop installed.230v,red door. VS1-RD One loop system,one 64-point loop installed. 110v,red door,with dialer. SA-TRIM1 VSi Flush mount trim,black Option Cards V-SLC2-1 Expansion module,one 250-device loop.For VS4 only, V-SLC2-2 Expansion module,two 250-device loops,500 devices total.For VS4 only. RZI16-2 Remote Zone Interface Module.16 Class B IDCs,2 Class B Output.Bracket included. SA-DACT Dual Line Dialer/Modem,supports Contact ID,mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers&computers,mounts in cabinet. SA-ETH Ethernet Port,IP Communicator,mounts in cabinet on base plate. SA-FSB Field Server Bridge for connection to 3rd Party Building Management Systems. Supports BACnet and Modbus protocols. Mounts in the MFCA cabinet using the FSB-BRKT2 mounting plate. See separate SA-FSB datasheet K85010-0157 for additional information SA-CLA Class A adapter module.Provides Class A capacity on NACs.Mounts in cabinet on • main board.VS1 systems only. SA-USB RS-232 Serial port for connection to printers&computers,mounts in cabinet D1 6L-VS LED Annunciator module,16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to right of LCD display.For VS4 only, D8RY-VS Canada only:LED Annunciator module,two LEDs per zone,16 zones(4 alarm onl)4 8 supervisory only,4 alarm or supervisory).Mounts in cabinet.For VS4 only. Accessories CTM City Tie Module.2-gang.Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet,8"x 14"x 3.5"-red. BC-1 Battery Cabinet.14.0"x 18.25"x 7.25'.Holds two 12V24A batteries. BC-1 R Battery Cabinet-Red.14.0"x 18.25"x 7.25".Holds two 12V24A batteries. GSA-REL Releasing Module BC-1 EQ Seismic hardening Kit for VS Series panels.Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools VS-CU VS Series configuration and diagnostics utility. 260097 RS232 cable,4 conductor,DB9 PC interface Page 8 of 8A T�% S l_E T K35005-0135 Not to as sa«° r,;;?al'. ,kio,, puiq son. Issue 2.0 • � ,> K*Idde :-<ata c;g> Intelligent Initiating _ E L' E'C-T R O,N:-1 C ;I Ila•. e - e e A 0 U R E`S S'-1•N.6, Technology that saves lives Manual PullOULL CASE Stations OLIPT THEN . PULL HANDL GSA-M270, GSA-M270P, • GSA-M278 FIR .. GSA-M270 SERIES � Ewdde UL GSA-M278, 7150-1483: 0139 MEA S2318 Overview • Break glass operation The GSA-M270 and GSA-M278 series Manual Pull Stations are An up-front visible glass rod on the GSA-M270 discourages part of Kidde's Signature Series system.The GSA-M270 Fire tampering. Alarm Manual Pull Stations feature our very familiar teardrop • Intelligent device with integral microprocessor shape.They are made from die-cast zinc and finished with red All decisions are made at the station allowing lower com- epoxy powder-coat paint complemented by aluminum colored munication speed while substantially improving control panel stripes and markings. With positive pull-lever operation,one pull response time. Less sensitive to line noise and loop wiring on the station handle breaks the glass rod and turns in a posi- properties;twisted or shielded wire is not required. tive alarm, ensuring protection plus fool-proof operation. Presignal • ADA Compliant models(GSA-M270P)are equipped with a general alarm(GA) Meets ADA requirements for manual pull stations. keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is • Electronic Addressing with Non-volatile memory not required for proper operation. Permanently stores programmable address,serial number, type of device,and job number.Automatically updates historic Kidde's double action single stage GSA-M278 station is a contem- information including hours of operation, last maintenance porary style manual station made from durable red colored lexan. date, number of alarms and troubles, and time and date of last • To initiate an alarm,first lift the upper door marked"LIFT THEN alarm. PULL HANDLE",then pull the alarm handle. • Automatic device mapping Each station transmits wiring information to the loop control- Standard Features ler regarding its location with respect to other devices on the Note:Some features described here may not be supported by all control Sys- circuit. tems.Check your control panel's Installation and Operation Guide for details. • Stand-alone operation • Traditional familiar appearance The station inputs an alarm even if the loop controller's polling GSA-M270 models feature our familiar teardrop design with interrogation stops. simple positive pull action and sturdy die-cast metal body. • Diagnostic LEDs • One stage(GA),two stage(pre-signal),and double action Status LEDs;flashing GREEN shows normal polling;flashing models RED shows alarm state. GSA-M270 models are available for one or two stage alarm • Designed for high ambient temperature operation systems.The single stage double action GSA-M278 features a Install in ambient temperatures up to 120°F(49°C). rugged Lexan housing with keyed reset mechanism. • Page 1 of 4 D P.-i•A �i E c, K85001-0279 .lot to ?)e casae for insta;iation purposes. Issue 1.1 Application Typical Wiring The operating characteristics of the fire alarm stations are deter- The fire alarm station's terminal block accepts#18 AWG(0.75mm2) mined by their sub-type code or"Personality Code". NORMALLY- to#12 AWG(2.5mm�wire sizes.See Signature Loop Controller OPEN ALARM-LATCHING(Pesonality Code 1)is assigned by the catalog sheet for detailed wiring requirement specifications. factory; no user configuration is required.The device is configured for Class B IDC operation.An ALARM signal is sent to the loop Wiring Notes controller when the station's pull lever is operated.The alarm con- Q Refer to Signature Loop Controller manual for maximum dition is latched at the station. wire distance. 2. All wiring is power limited and supervised. Compatibility REAR VIEW of 278 Signature Series manual stations are compatible only with Kidde's Signature Loop Controller. 0 p 0 0 TB2 Warnings & Cautions a 7 0 0 0 This device will not operate without electrical power.As fires freRed- quently cause power interruption,we suggest you discuss further "rm/AcBve) 0 0 GNormal) safeguards with your local fire protection specialist. O TBI O' Testing & Maintenance To test(or reset)the station simply open the station and operate DATA IN(+) DATA OUT(+) the exposed switch.The GSA-M270 series are opened with a tool; {DATA IN(-) [::::DATAOUT(-) the GSA-M278 requires the key which is supplied with that station. From Signature controller Y To Next Device or Previous Device Q The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message.The user-friendly maintenance Figure 4. Single Stage Systems program shows the current state of each Signature series device and other pertinent messages.Single devices may be deactivated temporarily,from the control panel.Availability of maintenance features is dependent on the fire alarm system used. REAR f iEw Scheduled maintenance(Regular or Selected)for proper system 2708 270PB C:)C:) operation should be planned to meet the requirements of the Authority Having Jurisdiction(AHJ).Refer to current NFPA 72 and o ° ULC CAN/ULC 536 standards. TBz 87as 0 0 0 Red LED Green LED (Alarm/Active) 4 0 0 (Normae TBI O ° o.o j(DATA IN(+) DATA OUT(+) l DATA IN(-) DATA OUT(-) From Signature Controller Y To Next Device or Previous Device Q Figure 5. Two Stage Systems Page 2 of 4 D A TA a;_i_r K85001-0279 Not to be used 'or instal::t;oo purposes. Issue 1.1 • Installation Single-stage Signature Series fire alarm manual pull stations mount to North American,21/2 inch(64 mm)deep 1-gang boxes. Two stage presignal(270P)models require 11/2 inch(38 mm)deep 4-inch square boxes with 1-gang,th-inch raised covers.Openings must be angular.Rounded openings are not acceptable. Recommended box:Steel City Model 52-C-13;in Canada,use Iberville Model CI- 52-C-49-1/2. All models include terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Kidde recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station,saving valuable time during system com- missioning.Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory.The loop controller identifies each device on the loop and assigns a"soft"address to each serial number. If desired,the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch Compatible Electrical Box Compatible Electrical Box Cover Release Cover Release I` Screwrrt, a ° Back Back Q Plate ° Plate Tag91e Toggle % Switch ° Switch ° Oa0R" N90A1 `§ ° Gt Glass Rod _ ! ® Glass Rod Release Lever OPEN D Figure 1. GSA-M278 installation Figure 2. GSA-M270 installation Cover Release Sc w F Comp atible Electrical Box ,. , withik-inch raised covers �Q 144 ° �. Back • I Plate 0 ` Toggle a Switch 1 NaRMA o � Glass Rod Release Lever Do not use boxes with rounded openings. Figure 3. GSA-M270P installation • Page 3 of 4 ID„-1 A 3 H E E:T K85001-0279 110"a to b,-,a,L,-i tnr inntzalieation purposes. issue 1.1 - -�— Specifications 7 Catalog Number GSA-M270 GSA-M270P, GSA-M278 �Sd ®i Single Action Single Action Two Double Action Description -One Stage Stage(Presignal) -One Stage Addressing Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Technology that saves lives Operating Current Standby=250pA Standby=396uA Standby=25OpA Activated=400pA Activated=68OpA Activated=400pA Contact us Diecast Zinc-Red Epoxy Lexan-Red with Phone: 888.244.9979(Option 4) Construction&Finish with aluminum markings white markings Email: kidde.fire@carriercom Type Code Factory Set Website: kidde-esfire.com Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominaq Kidde is a Carrier brand. Operating Temperature:32°F to 120°F(0°C to 49°C) 8985 Town Center Pkwy, Storage and Operating Storage Temperature:-4°F to 140°F(-20°C to 60°C)Humidity:0 to 93% • Bradenton,FL 34202 Environment RH On-board Green LED-Flashes when polled All rights reserved. ©2Carrier LED Operation On-board Red LED-Rashes w hen in alarm rights Compatibility Use With:Signature Loop Controller Agency Listings UL,ULC,MEA,CSFM,FM Ordering Information Ship Catalog Wt.lbs Number Description (kg) GSA-M270 One Stage Fire Alarm Station, English Markings -UL/ULC Listed GSA-M270P Two Stage(Presignaq Fire Alarm Station,English Markings 1 (0.5) -UL/ULC Listed GSA-M278 Double Action(One Stage)Fire Alarm Station,English Markings -UL/ULC Listed Accessories 270-GLR 20 Glass Rods-for GSA-M270 series (USA ONLY) 276-GLR 20 Glass Rods-for GSA-M278 series 0 Page 4 of 4 D AY.. S�-i c c 7 K95001-0279 Not tra ba s:5ed for:, t<;id=„'s.^o.irposey. (ssue 1.1 T Q;Df'3[`C;a!oq Intelligent Initiating Devices Aff Kidditt Technology that saves lives _ :. I nt Ili ent Sy-vnoke �R s Detector ;004 �•a•--�•.�t l �'" ~' 1 u� FM 7272-1657: ...wm 0511 Overview Standard Features The Kidde Intelligent Optica Series KI-OSD smoke detector brings • Patented multi-criteria optical smoke sensing technology advanced optical(photoelectric)sensing technology to a practical . Wide 0.5 to 4.36%/ft. (1.6 to 13.6%/m)smoke obscuration design that increases efficiency,saves installation time,cuts costs, and extends life safety and property protection capabilities. • Uses Existing Wiring Continuous self-diagnostics ensure reliability over the long-haul,while . Integrated nuisance rejection reducing unwanted alarms environmental compensation helps reduce maintenance costs. from general cooking particulates Like all Kidde Intelligent Optica Series detectors,the KI-OSD is a Listed to UL 268 7th edition an intelligent device that gathers analog information from multiple optical sensors,converting this data into digital signals.Utilizing • Automatic Device Mapping dual optical wavelengths combined with multiple detection angles, . Up To 250 Total Kidde Intelligent Addresses Per Loop the KI-OSD differentiates particles that are not representative of actual smoke. Particle data is input into digital filters which • Two Levels of Environmental Compensation feed a series of ratios removing signal patterns that are typical of • Two Levels of Dirty Detector Warning nuisance sources,thus reducing unwanted alarms.To make an alarm decision,the detector's on-board microprocessor measures Twenty Pre-Alarm Settings and analyzes all optical sensor readings and compares this • Five Sensitivity Settings information to preprogrammed settings. • Non-Volatile Memory • Electronic Addressing • Environmental compensation • Automatic Day/Night Sensitivity Adjustment • Bicolor(Green/Red)Status LED • Standard, Relay,Fault Isolator,and Audible Mounting Bases • Sensor Markings Provide Easy Testing Identification Note:Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Page 1 of 4 D,,.T�. SH F E T K55®01-1001 Not to be t:se•.t for installation purposes. Issue 1 Application Testing & Maintenance The KI-OSD detects particles from a wide range of combustion Each detector automatically identifies when it is dirty or defective sources and will trigger an alarm when smoke density in the and causes a"dirty detector"message.The detector's sensitivity chamber reaches preprogrammed level.Thanks to its high- measurement can also be transmitted to the loop controller. performance patented reflective response technology,the smoke A sensitivity report may be printed to satisfy NFPA sensitivity sensor responds quickly and reliably to a wide range of fire types, measurements,which must be conducted at the end of the first including both fast and slow burning fires fueled by combustibles year and every two years thereafter. typically found in modern multi-use buildings. The user-friendly maintenance program shows the current state of each detector and other pertinent messages.Single detectors Compatibility may be turned off temporarily from the control panel.Availability of p y maintenance features is dependent on the fire alarm system used. The KI-OSD detector is compatible only with control panels using a Kidde Intelligent Loop controller. Accessories InstallationDetector mounting bases have wiring terminals that are y accessible from the"room-side"after mounting the base to the Kidde Intelligent Series detectors electrical box.The bases mount to North American 1-gang boxes mount to North American 1-gang 6_.,._ ~, `� and to 3'/2 inch or 4 inch octagon boxes, 11/2 inches(38 mm) • boxes,3-1/2 inch or 4 inch deep.They also mount to European BESA and 1-gang boxes with octagon boxes,and to 4 inch ,-- Self-locking tab 60.3 mm fixing centers.The KI-SB4, KI-RB4, and KI-IB4 mount to square electrical boxes 1-1/2 North American 4 inch sq.electrical boxes in addition to the above inches(38 mm)deep.They boxes.They include the KI-TS4 Trim Skirt,which is used to cover mount to European BESA andrt, the"mounting ears"on the base.The KI-ABST mounts to a 4 inch 1-gang boxes with 60.3 mm =IED Indicator square box only. fixing centers.See mounting base installation and wiring for -. .�•�: � f` m�r:u�. I more information. t jli ` Sensing and reporting technology KI-ABST/ABDT/ABLT KI-SB KI-B KI-RB KI-LED The microprocessor in each detector provides additional Audible Base Standard Base Isolator Base Relay Base Remote LED benefits-Self-diagnostics and History Log,Automatic Device Remote LED GSA-LED-The remote LED connects to the KI-SB Mapping,and Fast,Stable Communication. or KI-SB4 Standard Base only.It features a North American size Self-diagnostics and History Log-Each Kidde Intelligent 1-gang plastic faceplate with a white finish and red alarm LED. Series detector constantly runs self-checks to provide important SIGA-TS4 Trim Skirt-Supplied with 4 inch bases, it can also maintenance information.The results of the self-check are be ordered separately to use with the other bases to help hide automatically updated and permanently stored in the detector's surface imperfections not covered by the smaller bases. non-volatile memory Sounder Bases-Kidde Intelligent Series sounder bases Automatic Device Mapping-The loop controller learns where are designed for use where localized or group alarm signaling each device's serial number address is installed relative to other is required. devices on the circuit.The mapping feature provides supervision of each device's installed location to prevent a detector from being a KI-ABST bases provide sounder capability to Kidde Intelligent reinstalled(after cleaning,etc.)in a different location from where it Series to heat and smoke detectors.They are not intended was originally. for use with combination carbon monoxide detectors in Fire- • plus-CO mode. Fast Stable Communication-On-board intelligence means plus-CT bases provide sounder capability to Kidde less information needs to be sent between the detector and the Intelligent Serres smoke and heat detectors,as well as Carbon loop controller.Other than regular supervisory polling response, monoxide detectors when used with aGSA-T3T4 Temporal the detector only needs to communicate with the loop controller Pattern Generator. when it has something new to report. • KI-ABLT bases provide 520 Hz low frequency sounder capability to Kidde Intelligent Series smoke and heat detectors,as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator.The KI- ABLT is suitable for applications requiring low frequency audible tones. Page 2 of 4 D AT A S;-'e F K85001-1001 Not to ba vst�c9 r"" r in:lY^li'>3ilrii purposes. Issue f Typical Wiring The detector mounting bases accept#18 AWG(0.75mm2),#16 /Audible Sounder Bases,Fire Mode (1.0mm2),#14 AWG(1.5mm2),and#12 AWG(2.5mm2)wire sizes. RBST,ABDT,ABLT sounder bases Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. Standard Detector Base,KI-SB,KI-SB4 KI-ABST o D K-AB LT: KI-ABDT JmtOutput Made ode This is the basic mounting -ABLT: upercus Default=Fire base for KIDDE Intelligent Series Remote LED Volume Setting Cut/remove Jumper g Default=High for Fire plus CO detectors.The GSA-LED Max resistance Cuttremove kpee ijumper for KI-ABST: Remote LED is supported by + IOW dB ® ® Tone Setting this Base. DffA-DATA-DATA. Default=Temporal sic+sic- ourwIWouTCut/removejumper Tenn Description for Steady 1 Not Used O 2 DATA IN/OUT(+) 3 Not Used 4 DATA IN(-) DATA IN 11 sOUT t-) 4 Remote LED(-) 5 Remote LED(+) 6 Not Used DATA IN W DATA OUT 1+) 24 supVdc ly - • 7 DATA OUT(-) From SLC or To Next Device From powers base ' To Vdc out or previous base + + To next base or EOL relay Previous Device Data In _ Data out Isolator Detector Base,KI-IB,KI-IB4 From IOdde Controller or + + to next Kidde device previous device This base includes a built-in line fault isolator for use on Class A circuits.A detector must be installed for it to operate.The isolator base does not support the GSA-LED Remote LED. Warnings & Cautions The isolator operates as follows: • This detector does not operate without electrical power. -a short on the line causes all&(-) z As fires frequently cause power interruption, discuss isolators to open within 23 mfurther safeguards with the local fire protection specialist. -at 10 msec intervals,beginni • This detector does not sense fires in areas where smoke on one side of the Class Acircuit nearest the loopcannot reach the detector.Smoke from fires in walls, controller,the isolators DATOUT(-) roofs,or on the opposite side of closed doors may not close to provide thereach the detector. next isolator down DATA IN(+) DATA OUT(+) . In Canada, install according to CAN/ULC-S524 Standard for the line with power. From Kidde Controller To Next Device the Installation of Fire Alarm Systems,CSA C22.1 Canadian or Previous Device Tern Description -when the isolator next 1 Not Used Electrical Code,and the local authority having jurisdiction. to the short closes,it 2 DATA IWOUT(+) 3 DATA IN(-) reopens within 10 msec. 4 Not used 5 Not Used The process repeats beginning on 6 DATA OUT the other side of the loop controller. 7 Not Used Relay Detector Base, KI-RB,KI-RB4 This base includes a relay. Normally-Normally- Common Closed Open Normally Open or Normally Closed operation is selected during installation.The dry O contact is rated for 1 amp (pilot duty)®30 Vdc.The < o relay's position is supervised to avoid accidentally jarring it DATA IN(-) e DATA Our c-) out of position.The KI-RB can be operated as a control DATA IN(+) ToDATA OLYr Next Devl(ce From Made Controller relay if programmed to do so or Previous Devlce Tenn Description at the control panel.The relay 1 Normally Open base does not support the CONTACT RATING 2 DATA IWOUT(+) 1.0 Amp®30 VDC 3 Common GSA-LED Remote LED. (Pilot Duty) 4 DATA IN(-) 5 Not Used 6 Normally-Closed 7 DATA OUT- Page 3 of 4 D A T :3 iW w T K85001-1001 I Not t, be used for inst<aiiavon purpose,;_ Issue 1 Dimensions �A160 • Kidde CDA :378 Technology that saves lives � � INroaION oa Contact us Phone: 888.244.9979(Option 4) S7°' Email: WiddeJire@carrier.com Website: kidde-esflre.com \ Kidde is a Carrier brand. 8985 Town Center Pkwy, • Bradenton,FL 34202 © Specifications 2020 Carrier All rights reserved. Operating voltage 15.20 to 19.95 VDC Normal operating current 32 pA - - - -- --- - - Alarm current 45 pA Smoke Sensitivity Range UL/ULC:0.5 to 4.36%/ft.(1.6 to 13.6%/m)obscuration Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft./min(0 to 20 m/s) Wall mounting 12 in.(305 mm)max.from ceiling Compatible bases See Ordering Information Compatible detector testers Testifire 1000,Testifire 2000 Operating environment 32 to 120°F(0 to 49°C),0 to 93%RH,noncondensing Construction High Impact Engineering Polymer,White Storage temperature -4 to 140°F(-20 to 60°C) Environmental compensation Automatic Agency Listings CAN/ULC-S529,UL 268-7,UL 268A,CSFM,FM Ordering Information Catalog ®ascription Ship Wt. Number 'Ibs(kg) KI-OSD Intelligent Optical Smoke Detector 0.4(0.16) Accessories KI-SB Detector Mounting Base-Standard • KI-SB4 4-inch Detector Mounting Base c/w Trim Skirt KI-RB Detector Mounting Base w/Relay KI-RB4 4-inch Detector Mounting Base w/Relay,c/w Trim Skirt 0.2(.09) KI-IB Detector Mounting Base w/Fault Isolator KI-1134 4-inch Detector Mounting Base w/Fault Isolator,c/w Trim Skirt GSA-LED Remote Alarm LED KI-ABST Audible(Sounder)Base for Fire Detectors 0.3(0.15) KI-ABLT Low Frequency Audible(Sounder)Base for CO and/or Fire Detectors 0.3(0.15) KI-ABDT Audible(Sounder)Base for CO and/or Fire Detectors 0.3(0.15) GSA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1 (0.04) GSA-TS Trim Skirt-(optional for non 4-inch bases) 0.1 (0.04) GSA-DMP Detector Mounting Plate 3.0(1.4) SIGA-RTA Detector Removal Tool SIGA-VA Detector Cleaning Tool Page 4 of 4 D A T As r,2 T.a 1 K55001-1001 Not tra be used ::r ir„tallatinu purpas^s>. Issue 1 ® KlDD[` .cfi t>Strobes,Horns,Bells,Chimes AMY&Iddt' ! Technology that saves livesLERT ,y i o s•o••.....♦♦s s... i -. s•s s s•♦s•s s s saw i z ••••••°••••••aact enesis L .......°....... i ,00000001 OOQ 00000 { 00*0 0040���0/4 010 ! 0®0000000000®00 ! EG 1 Series A-V Compact Notification Devices rj; 7125-1657:0506 7135-1�6�577::0502 1 v Overview Standard Features <::FM Genesis LED EG1 Series horns and LED strobes feature a sleek High Performance LED Strobe Technology APPROVED low profile design and energy-efficient technology that makes -Ultra low device current consumption them less expensive to install and operate by reducing overhead. -High efficiency optics High performance LEDs require fewer circuits and power supplies. -Selectable 15,30,or 75 cd light output These new appliances are designed with energy-efficiency and life -LED devices may be mixed with legacy Xenon strobes safety in mind. • Efficient Audible Output Genesis LED EG1 Series uses high efficiency optics,combined -Selectable high or low dB horn output with patented electronics,to deliver a highly controlled and -Selectable temporal or steady horn output efficiently focused light distribution pattern in exchange for lower -Improved audio frequency range for better wall penetration current requirements.Strobes feature field-selectable 15, 30, Low-profile Design or 75 cd light output. ° -Compact design—single gang mounting Compared with Xenon-type strobes, Genesis LED EG1 Series -Ultra-slim—protrudes about 1"from the mounting surface appliances need fewer power supplies and often smaller wire -Attractive appearance—no visible mounting screws � gauge,which lightens conduit requirements.They are also • Multiple Cover Options backwards compatible with legacy strobes,so there's no need -Order with FIRE markings or no FIRE markings in both to replace all your existing devices to upgrade to new LED red and white technology. In fact, EG1 strobes can be mixed on the same circuit -Change markings at any time with quick-swap covers and used in the same field of view as Xenon-based strobes.This makes Genesis LED EG1 Series ideal for new installations and Easy to Install retrofits alike. -Diagnostic test points streamline device circuit testing Field-configurable sound output levels provide the flexibility -Fits standard 1-gang electrical boxes, no trim ring needed modern life safety projects demand,while the Genesis LED -Optional trim ring available for 4-inch square boxes control protocol keeps multiple strobes on compatible NAC -Slide switches for field configuration circuits synchronized to well within NFPA 72 requirements. -12 to 18 AWG in-out screw terminals for quick wiring Serviceability is another area where EG1 Series appliances shine. The innovative under-cover diagnostic test points provide easy access to device circuit testing while mounted. Page 1 of 6 D AT,-, S H E E T K65001-0667 Nott, bo I rc,�installation purposes. Issue 1.2 Application Genesis LED EG1 Series horns and strobes mount to any Strobes standard one-gang surface or flush electrical box. Matching optional EG1T trim rings are available to cover oversized openings Genesis LED EG1 Series strobes are UL 1971-listed for use and can accommodate one-gang or four-inch square boxes, indoors as wall-mounted public-mode notification appliances Optional color matched single-gang surface boxes are also for the hearing impaired. Prevailing codes require strobes to be available. used where ambient noise conditions exceed 105 dBA(87 dBA in Canada),where occupants use hearing protection,and in One-gang areas of public accommodation as defined in the Americans Electrical Box Trim Ring Backplate with Disabilities Act. Synchronization is important in order to avoid epileptic sensitivity. All Genesis LED strobes exceed UL synchronization requirements Signaling Appliance (within 10 milliseconds over a two-hour period)when used with a synchronization source.See the specifications table for a list Appliance Cover of compatible sources. Horns Genesis LED horn output reaches as high as 92 dBA and features an improved audio frequency range compared with other Genesis Two-gang LED horns.This results in excellent sound penetration through Electrical Box walls and a clear warning of danger.They can also be set for high or low dBA output.This setting reduces horn output by about 6 dBA.Models may be ceiling-mounted or wall-mounted and may be configured for either coded or non-coded notification appliance Optional circuits. Trim Ring Using a trim ring is optional The suggested sound pressure level for each signaling zone used 4-inch Octagon except when installing the with alarm signals is at least 15 dBA above the average ambient ® Electrical Box signaling appliance on electrical sound level,or 5 dBA above the maximum sound level having a boxes greater than three inches duration of at least 60 seconds,whichever is greater.These values wide. are measured at five feet(1.5 m)above the floor.The average ambient sound level is A-weighted,fast response sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically ® 4-inch Square result in a 6 dBA reduction of the received sound pressure level. ® ® Electrical Box The actual effect depends on the acoustic properties of materials in the space.A 3 dBA difference represents a barely noticeable change in volume. Installation Wiring All Genesis LED devices come with mounting screws for easy installation.The tab at the bottom of the device unlocks the cover to reveal the mounting holes.The shallow depth of Genesis LED Horn strobe Horn/strobe devices leaves ample room behind them for extra wiring.Once circuit in circuit out installed with the cover in place, no mounting screws are visible. + + ® w ® CD 00 0 Signal polarity shown in the active condition. 0 O 0 Page 2 of 6 DATA S H E E T @465001-0667 IJot to be used for�n3 aii:tion purposes. Issue 1.2 Dimensions Field Configuration EG1 Notification Appliances Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern.By sliding the tone selector 2.86 cmLj 3° switch, units may be configured for constant horn output that (7.62 cm) can be coded at precise intervals by KIDDE control panels and control modules. % Note:Temporal 3 coding is the required output for fire notification vovovooeoov00000 0000000000000000 devices per NFPA 72.Any device coding other than temporal 00000000000 00 3 is at the discretion and approval of the local authority having jurisdiction(AHJ). 4-5/8° Horns and horn-strobes are factory set for high dB output. Low (11.75 cm) dB output may be selected by sliding the tone selector switch. This reduces the output by about 6 dBA. Genesis LED clear strobes and horn-strobes may be set for 15, 30,or 75 candela output.The output setting is changed by simply removing the cover and sliding the candela switch to the desired setting.The device does not have to be removed from the wall Of to change the output setting.The setting remains visible through a small window on the left-hand side of the device after the cover EGiT Trier Ring is closed. 9/16° T3 temporal horn,high dB (1.43 cm) 5° (12.7 cm) T3 temporal horn,low dB Constant horn,high dB Constant horn,low dB 5-7/8" (14..9292 cm) 75 candela 30 candela � O 15 candela Operating current Horns Strobes Sound 16 to 33 16 to 33 Strobe 16 to 33 16 to 33 setting VDC VFWR setting VDC VFWR C-LOW 13 mA 15 mA 15,30,75 24 mA 32 mA Diagnostics T-LOW C-High ! .! T-High 23 mA 29 mA 0 0 + Horn-Strobes Strobe Sound setting 16 to 33 VDC 16 to 33 VFWR o setting 15,30,75 C-Low,T-Low 35 mA 43 mA C-High,T-High 45 mA 55 mA Test points indicated above are used to validate the Notification Appliance Circuit and verify device function. Page 3 of 6 DATA s H L l a K8.5001-0667 Mot to be used rar instzilation purposas. Issue 1.2 Sound Output Light Distribution Reverberant Anechoic Sound setting (UL 464) (CAN/ULC S525) Horizontal Left zo 15 10 0 5 10 15 Horizontal Right C-Low zo T-Low 80 dBA 86 dBA 35 30 25 25 30 35 40 40 C-High 85 dBA 92 dBA 45 , t 45 T-High 50 50 60 5 ' 55 ! 60 65 65 Sound pattern(ULC) 70 70 75 y / 75 Axis Angle Change in output 80 so 45°and 115° -3 dBA ,u Horizontal 85 5°and 130° -6 dBA 90 _ 90 65°and 135° -3 dBA — 5 Vertical 45°and 140° -6 dBA j 15 20 25 30 • 35 40 45 50 55 60 90 65 60 75 65 70 Vertical Bottom Measured — — UL Minumum Specifications Operating voltage 16 to 33 VDC, 16 to 33 VFWR Horn signal type Constant or T3 temporal Light output 15,30,or 75 candela Strobe flash rate 1 fps(flash per second)approx. 20 0 max.between any two devices. Synchronization (To determine allowed wire resistance,refer to these specifications, and the specifications for the synchronized signal source.) Synchronization sources KIDDE CC Series Signal Modules,Booster and Auxiliary Power Supplies, and Intelligent and Conventional Control Panels Wire size 12 to 18 AWG(0.75 to 2.50 mm2) Dimensions(WxHxD) 3 x 4-5/8 x 1-1/8 in.(7.62 x 11.75 x 2.86 cm) Strobe-to-box center offset -0.71 inches(-1.8 cm) Compatible electrical boxes[1] 1-gang,2-gang,4-inch octagon,4-inch square Trim rings EG1TR,EG1TW-Dimensions 5 x 5-7/8 x 9/16 in.(12.7 x 14.92 x 1.43 cm) Agency Listings FCC,]CC,UL1971,UL1638,UL464,CSFM (All models comply with ADA code of federal regulation Chapter 28 Part 36 final rule) Operating environment Temperature 32 to 122°F(0 to 50°C) Relative humidity 0 to 93%noncondensing [1]Electrical boxes must be at least 1-1/2 in.(3.81 cm)deep.Electrical boxes greater than three inches wide require a trim ring. Page 4 of s C ATA v E E T K65001-0667 Not to be us€d ;cr pu poses. issue 1.2 Ordering Information Notification Appliances •I or e Replacement Appliand&d0ebrs EGIARF Red FIRE EGIARN-CVR Red None EGIARN Red None EGIAWA-CVR White ALERT Horns EGIAWF White FIRE Horn Selectable Covers EGIAWN-CVR White None High/lowdB EGIAWN White None EGIVRN-CVR Red None EGIVRF Red FIRE EGIVRN Red None EGIVWA-CVR White ALERT Strobe Strobes EGIVWF White FIRE Covers EGIVWN-CVR White None Selectable 15,30,75 cd EGIVWN White None • EGIAVRN-CVR Red None EGIAVRF Red FIRE ; EGIAVWA-CVR White ALERT Rai EGIAVRN Red None Horn-strobe EGIAVWN-CVR White None Covers Horn-strobes Selectable EGIAVWF White FIRE 15,30,75 cd, High/low dB EGIAVWN White None Accessories EG1TR Trim ring,EG1 Series,red = I EG1TW Trim ring,EG1 Series,white 27193-11 One-gang surface mount box,red 27193-16 One-gang surface mount box,white Model Number Syntax,Appliances Model Number Syntax, Replacement Covers Genesis LED Series Genesis LED Series EGi=Wall mount appliances EG1=Wall mount appliances Housing Color Housing Color R=Red R=Red W=White W=White over EG 1 AVRF Housing Marking EG 1 AVRF-CVR Designation N=None •ALERT Marking F-FR=FEU available on white I Cover Marking F-SP=FUEGO strobe model with N=None It Functions F=FIRE clear lens only. Functions F-FR=FEU A=Horn only A=ALERT` See replacement A=Horn only F-SP=FUEGO V=Strobe only covers for more V=Strobe only F=FIRE AV=Horn-Strobe options. AV=Horn-Strobe A=ALERT Page 5 of 6 D.,T A S I I 2 E T K85001-0667 Not to au ua ti.s.':SMr in,kallaUon purposes. Issue 1.2 Qp idde Technology that saves lives Contact us... Email: kddde.fire®fs.utc.com Web: kidde.com/engineeredsystems 1016 Corporate Park Drive Mebane,NC 27302 Kidde is a registered mark in the United States and other countries. • ©2019 Walter Kidde Portable Equipment. All rights reserved. Page 6 of 6 D ATA F E E T K85001-0667 Not to be used tis r i 11...ion purposes. Issue 1.2 D POTTER BELLS ® The Symbol of Protection PBA AC&MBA-DC Features • Listed for indoor and outdoor use t • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4"box • Low current draw o • High dB output "` • AC and DC models 1 • DC models are motor driven,polarized,and have built in transient protection for supervised alarm circuits • Available in 6",8"and 10"sizes _ * V V CFM APPROVED *ULC on MBA-DC Only Description Technical Specifications These vibrating type bells are designed for use as fire or general Dimensions 6"(150mm),8"(200mm)and 10"(250mm) signaling devices.They have low power consumption and high decibel Cover.Steel Finish:Red Powder Coat ratings.The unit mounts on a standard 4"(101mm)square electrical Base:non-corrosive composite material box for indoor use or on a model BBK-1 or HC-BB weatherproof Enclosure All parts have corrosion resistant finishes backbox for outdoor applications.Weatherproof backbox model BBK- Model BBK-1 or HC-BB weatherproof backbox(optional) 1 or HC-BB,Stock No. 1500001. 24VAC Voltages Available 120VAC 12VDC(10.2 to 15.6)Polarized Notes 24VDC(20.4 to 31.2)Polarized 1. Minimum dB ratings are calculated from integrated sound pressure Indoor or outdoor use(See Note 1) measurements made at Underwriters Laboratories as specified in Environmental 40°to 150T(40°to 66°C) Limitations UL Standard 464. UL temperature range is-30°to 150°F(-34°to (Outdoor use requires weatherproof backbox.) 66-C) AC Bells-4 No.18 AWG stranded wires 2. Typical dB ratings are calculated from measurements made with a Termination DC Bells-Terminal strip conventional sound level meter and are indicative of output levels service use NFPA 13,72,local AHJ in an actual installation. 3. ULC only applies lies to MBA DC bells. *Specifications subject to change without notice. Size inches Voltage Model Stock Current Typical dB at Minimum dB at ,�j1da,Ra�� + i ¢. (mm) Number Number (Max.) 10&(3m)(2) 10 ft.(3m)(1) Ave 6(150) 12VDC MBA-6-12 -1750070 .12A 85 76 Installation must be performed by qualified personnel and in accordance with all 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 national and local codes and ordinances. • Shock hazard.Disconnect power source before.servicing.Serious injury or death 10(250) 12VDC MBA-10-12 1750060 .12A 92 78 could result. 6(150) 24VDC MBA-6-24 .1750100 .06A 87 77 Risk of explosion.Not for use in hazardous locations.Serious injury or death 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 could result. 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 _a , r•- 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 In outdoor or wet installations,bell must be mounted with weatherproof backbox, 6(150) 120VAC PBA1206 1806120* .05A 92 83 BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an 8(200) 120VAC PBA1208 1808120* .05A 99 84 electrical hazard. 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com • 5400776-REV Z 11/17 PAGE 1 OF 2 • POTTER BELLS ® The Symbol of Protection PBA AC&MBA-DC Installation The bell shall be installed in accordance with NFPA 13,72,or local AHJ.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. 1. Remove the gong. 2. Connect wiring(see Fig.3). 3. Mount bell mechanism to backbox(bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). Weatherproof Backbox Dimensions • eWARNING ` .. ; a ,,, .; /,.. Inches (mm) Failure to install striker down will prevent bell from ringing. MODEL BBK-1 OR HC-BB Fig 2 Bell Dimension Inches (mm) _ Fig I ° 5 3/4" _ 3 3/8" 5" (146—) 0 (86 mm) (127 mm) 10" (250 mm) 8„ r (200 mm) 6.+ (150 mm) ✓ J (41 (86 mm) � 41/4" �.---- (108 mm) 2 11/16" ° (68 mm) DWGq 776-1 ° 0 e e Wiring Rear View Fig 3 D.C. BELLS (OBSERVE POLARITY) A.C. BELLS • RED (IN) RED (OUT) WHITE (IN) WHITE (OUT) 0 0 FROM CONTROL PANEL TO NEM BELL FROM CONTROL PANEL OR OR END—OF—LINE OR PRECEDING BELL RESISTOR PRECEDING BELL BLACK (IN) BLACK (OUT) BLACK (IN) 0COLACK CAUTION- CAUTIO WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN, WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY 2. RED WIRES POSITIVE (+). AFTER LAST BELL. 3. BLACK WIRES NEGATIVE (-). 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS . 4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com • 5400776-REV Z • 11/17 PAGE 2 OF 2 Intelligent Input-Output r *dde KI •. o A D D R E S S I N.6 . Technology that saves lives hp, it Mue tz;o GSA-CT1 , GSA-CT1 HT, GSA-CT2, GSA-M CT2 t i MEA 7300-1483: 0115 GSA-CTI/2 �L GSA-MCT2 63424 Overview Standard Features The GSA-CT1 Single Input Module,GSA-CT1 HT High Multiple applications Temperature Single Input Module and GSA-CT2/GSA-MCT2 Dual Including Alarm,Alarm with delayed latching(retard)for Input Modules are intelligent analog addressable devices used to waterflow applications, Supervisory,and Monitor.The installer connect one or two Class B normally-open Alarm,Supervisory,or selects one of four"personality codes"to be downloaded to Monitor type dry contact Initiating Device Circuits(IDC). the module through the loop controller. The actual function of these modules is determined by the • GSA-CT1 HT rated for high temperature environments "personality code"selected by the installer.This code is downloaded Suitable for attic installation and monitoring high temperature to the module from the Signature loop controller during system heat detectors. configuration. Plug-in(U10)or standard 1-gang mount The input modules gather analog information from the initiating U10 versions allow quick installation where multiple modules are required.The 1-gang mount version is ideal for remote devices connected to them and convert it into digital signals. locations that require a single module. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. Automatic device mapping Signature modules transmit information to the loop controller 0 The GSA-CT1,GSA-CT1 HT and GSA-CT2 mount to standard regarding their circuit locations with respect to other Signature North American 1-gang electrical boxes, making them ideal for devices on the wire loop. locations where only one module is required.Separate 1/0 and Electronic addressing data loop connections are made to each module. Programmable addresses are downloaded from the loop The GSA-CT1 HT module operates at an expanded temperature controller, a PC,or the Signature Program/Service Tool. range of 32 OF to 158 OF(0°C to 70°C)for those applications There are no switches or dials to set. requiring more extreme environmental temperature variation. • Ground fault detection by address The GSA-MCT2 is part of the UIO family of plug-in Signature Detects ground faults right down to the device level. Series modules. It functions identically to the GSA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules.Two-and six-module U10 motherboards are available.All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclosures. • Page 1 of 4 DATA SH E E K85001-0241 ?der t [J., purposes. Issue 1.1 Signature Series Overview Motherboard The Signature Series intelligent analog-addressable system f' from Kidde Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels,and user- friendly maintenance and service tools.Analog information from Plug-in(U10) equipment connected to Signature devices is gathered and Module converted into digital signals.An onboard microprocessor in each Signature device measures and analyzes the signal and ----- decides whether or not to input an alarm.The microprocessor in each Signature device provides four additional benefits—Self- diagnostics and History Log,Automatic Device Mapping,and Fast, Stable Communication. Electronic Addressing-The loop controller electronically Self-diagnostics and History Log—Each Signature Series addresses each module,saving valuable time during system device constantly nuns self-checks to provide important commissioning.Setting complicated switches or dials is not maintenance information.The results of the self-check are required. Each module has its own unique serial number stored automatically updated and permanently stored in its non-volatile in its on-board memory.The loop controller identifies each device memory.This information is accessible for review any time at the on the loop and assigns a"soft"address to each serial number. . control panel, PC, or using the Signature Program/Service Tool. If desired,the modules can be addressed using the Signature Automatic Device Mapping The Signature Data Controller Program/Service Tool. (SDC)learns where each device's serial number address is Kidde recommends that this module be installed according to installed relative to other devices on the circuit.The SDC keeps a latest recognized edition of national and local fire alarm codes. map of all Signature Series devices connected to it.The Signature Series Data Entry Program also uses the mapping feature.With interactive menus and graphic support,the wired circuits between Application each device can be examined. Layout or"as-built"drawing pp information showing branch wiring(T-taps), device types and their The duty performed by the GSA-CT1 and GSA-CT2/MCT2 is address are stored on disk for printing hard copy. determined by their sub-type code or"Personality Code".The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. Installation One personality code can be assigned to the GSA-CT1.Two GSA-CT1,GSA-CTI HT and GSA-CT2:modules mount to North personality codes can be assigned to the GSA-CT2/MCT2. American 21/2 inch(64 mm)deep 1-gang boxes and 11/2 inch(38 Codes 1,2,3 and 4 can be mixed on GSA-CT2/MCT2 modules mm)deep 4 inch square boxes with 1-gang covers and GSA-MP only. For example, personality code 1 can be assigned to the first mounting plates.The terminals are suited for#12 to#18 AWG(2.5 address(circuit A)and code 4 can be assigned to the second MM2 to 0.75 mm2)wire size. address(circuit B). NORMALLY-OPEN ALARM-LATCHING(Personality Code 1) -Assign to one or both circuits. Configures either circuit A or B or Compatible electrical box both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors,etc.An ALARM signal is sent to the loop controller when the input contact is closed.The alarm condition is latched at the module, Wall plate,white NORMALLY-OPEN ALARM -DELAYED LATCHING (1-gang) (Personality Code 2)-Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiating devices such as Waterflow Alarm Switches.An ALARM signal is sent to the loop controller when the input contact is Q closed for approximately 16 seconds.The alarm condition is , latched at the module. Status LEDs s, NORMALLY-OPEN ACTIVE-NON-LATCHING(Personality LED viewing ports . ��. Code 3)-Assign to one or both circuits. Configures either circuit o A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors,etc.An ACTIVE signal is sent to the loop controller when the input contact is closed.The GSA-MCT2:mount the UIO motherboard inside a suitable Kidde active condition is not latched at the module. enclosure with screws and washers provided. Plug the GSA- NORMALLY-OPEN ACTIVE-LATCHING(Personality Code MCT2 into any available position on the motherboard and secure 4)-Assign to one or both circuits. Configures either circuit A or the module to the motherboard with the captive screws.Wiring B or both for Class B normally open dry contact monitoring input connections are made to the terminals on the motherboard(see such as from Supervisory and Tamper Switches.An ACTIVE signal wiring diagram). UIO motherboard terminals are suited for#12 to is sent to the loop controller when the input contact is closed.The #18 AWG(2.5 mm2 to 0.75 mm2)wire size. active condition is latched at the module. Page 2 of 4 DATA S H e E T K55001-0241 Not to be used for installation purposes. Issue 1.1 Typical Wiring Modules will accept#18 AWG(0.75mm2),#16(1.0mm2),and#14AWG(1.50mm2), and#12 AWG(2.50mm2)wire sizes. Note: Sizes#16 AWG(1.Omm2)and#18 AWG(0.75mm2)are preferred for ease of installation.See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave)Device Circuit Dire Specifications Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference Wire Size Maximum Distance to EOLR #18 AWG(0.75 mm2) I #16 AWG(1.00 mm� 4,000 ft(1,219 m) #14 AWG(1.50 mm2) #12 AWG(1.50 mm2) Typical N.O.Initiating Device Typical N.O.Initiating Device 1 INPUT 1 INPUT 2 0 AA style B(Class B) TB2 N 8 7 UL/ULC Listed Style B(Class B) o a o - 47KQ EOL UL/ULC Listed 8 7 6 5 UUULC Listed 47M EOL 0 0® 0 0 0 47Kn EOL Red LED Green LED (Alarm/Active) ® (Normal) Red LED ® ® Green LED 4 8 2 1 (Alarm/Active) 4 3 2 1 (Normal) T131 TBI { DATA IN W DATA OUT(+)lr DATA IN(+) DATA OUT(+)lF DATA IN(-) > DATA OUT(-)/ DATA IN(-) DATA OUT(-)1 To Next Device From Signature Contro0er To Next Device From Signature Controller or Previous Device or Previous Device Q A GSA-CT1, GSA-CT1 HT GSA-CT2 I-II Typical NOlnitlatin9 D°Wce NOTES uwLcumd uwLc,M-.I 47KW EOLnhpM2 InW1 7 47KWEOL 1Q Maximum 25 Ohm resistance per wire. 11c, 20 Maximum#12 AWG(2.5 mm2)wire;Minimum#18 AWG(0.75 mm2). AAA 03 Refer to Signature controller installation sheet for wiring specifications. • 44 Maximum 10 Vdc @ 350 NA MCR 5s The GSA-U106R and the GSA-U102R do not come with TB14. Q 1234 ulolw.ede:marroaed d 3 6 All wiring is supervised and power-limited. + Data m_ 3 7 These modules will not support 2-wire smoke detectors. : ° 4 slgw m 3 Tg14 0a i No wnnectlons required for MCR a—It Te OMnr modules may requln Warnings & Cautions Da�DaL± 4 reen 3 GLED INormal ®3 This module will not operate without electrical power.As fires Ked LED IAcWv; frequently cause power interruption,we suggest you discuss further safeguards with your local fire protection specialist. qulred for MCR. Compatibility GSA-MCT2 These modules are part of Kidde's Signature Series intelligent processing and control platform.They are compatible with VM, and VS Series control panels. Page 3 of 4 k--A z;:'2;=-I- K85001-0241 Not to Lre 11sar' ^r;., tniizl>i a:purposes. Issue 1.1 Specifications Catalog Number GSA-CTIHT GSA-CTI GSA-CT2 I GSA-MCT2 >4 Description Single Input Module Dual Input Module Kidde Type Code 48(factory set)Four sub-types 49(factory set)Four sub-types (personality codes)are available (personality codes)are available Address Requirements Uses One Module Address Uses Two Module Addresses Technology that saves lives Operating Current Standby=25OpA; Standby=396pA; Activated=400pA Activated=680pA Contact us Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Phone: 888.244.9979(option 4) Construction High Impact Engineering Polymer Email: kidde.fire@oarriercom Website: kidde-esfire.com Mounting North American 21/2 inch(64 mm)deep one-gang box- U102R/6R/6 Kidde is a Carrier brand. es and 11/2 inch (38 mm)deep 4 inch square boxes Motherboard 8985 Town Center Pkwy, with one-gang covers and GSA-MP mounting plates Bradenton,FL 34202 Operating Environment 32°F to 158°F 32°F to 120°F(0°C to 49°C) (0°C to 70°C) ©2020 Carrier Storage Environment -4°F to 140°F(-20°C to 60°C);Humidity:0 to 93%RH All rights reserved. LED Operation On-board Green LED-Flashes when polled;On-board Red LED- Flashes when in alarm/active. Both LEDs-Glow steady when in alarm Compatibility Use with Signature Loop Controller Agency Listings UL,ULC,MEA,CSFM Ordering Information Catalog Ship Wt. Number Description lbs(kg) GSA-CT1 Single Input Module—UL/ULC Listed 0.4(0.15) GSA-CT1 HT Single Input Module High Teperature Operation UL/ULC Listed 0.4(0.15) GSA-CT2 Dual Input Module—UL/ULC Listed 0.4(0.15) GSA-MCT2 Dual Input Plug-in(UIO)Module —UL,ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box-Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box-White,1-gang 1.0(0.6) GSA-UI02R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) —Two Module Positions GSA-UI06R Universal Input-Output Module Board w/Riser Inputs 0.62(0.28) —Six Module Positions GSA-U106 Universal Input-Output Module Board —Six Module Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet—Red,supports Signature Module 7,0(3.1) • Mounting Plates GSA-MB4 Transponder Mounting Bracket(allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) GSA-MP1 Signature Module Mounting Plate,1 footprint 1.5(0.70) GSA-MP2 Signature Module Mounting Plate,1/2 footprint _ 0.5(0.23) GSA-MP2L Signature Module Mounting Plate,1/2 extended footprint 1.02(0.46) Page 4 of 4 DAT), :3 K8500_1-®241 Not to be used ;puT uses. Issue 1.1 tran ireCommercial :Fire Alarm Ceiiu(ar,&Ior IP 9' ' } CO CELLULAR&'IP,'': .Ll F* Flre'.Aiarm L 'E Communicators. . ,. �_...NIMERCIAL.FIRE.V_._____�."........__..�. ___.__�_....._____ ._. .�.. ..�..._ __:Y____.._._..W.R�.........-...__�._ • Universal full event sole&dual path cellular Wor IP UL and NFPA 72 Fire Code-Compliant,the Starl-ink commercial fire alarm reporting from any panel brand, Series Wireless Commercial Fire Alarm Sole Path&Dual virtually anywhere Path Communicators provide universal support for any brand 12V to 24V fire alarm control panel,reporting in • Code-compliant,replaces 2POTs lines per FACP saves Contact ID and 4/2. With broadest Verizon LTE coverage thousands of dollars per year over the leased landlines footprint available,via most extensively deployed LTE CAT1, • Supports 12V-24 control panels and FACPs that using proven StarLink circuitry,they are also available communicate using Contact ID and 4/2(such as on legacy in mercantile locking metal models.All provide the most panels),as primary or backup economical solution for easy,versatile installation.Also regional compliances,i.e.,CSFM,NYCFD,LAFD and more. • Full data Reporting to any Central Station nationwide, via Verizon®LTE Network,"The Nations largest and most Easy,Universal Installation at Fire Communications Panel- reliable LTE network.Rated#1 overall network,proven to Powered Technology".StarLink Fire Communications are easily connected to any panel or Fire Alarm Control Panel 0 deliver consistently fast speeds ad i more places than any (FACP)standardly operating between 12V and 24V.Flexible other network"t in any application,Starl-ink Fire also comes in standard,or • Communicate critical life and safety alarm reports on Mercantile Models in metal housings,with code-compliant LTE(Long Term Evolution)10+year life,cyber-protected supervision,and choice of power options,Panel-Powered multi-billion dollar cellular network,for maximum life Technology"(powered by the panel),or direct-connect safety&liability protection 120VAC models.Signal Boost circuitry&dual diversity antennae for maximum signal acquisition&null avoidance, • Easiest installation,powered by panel,NO extra power receiving signals simultaneously on both antennae. supply, NO conduit,self supervised on 4 wires Flexible Performance&Reporting Options.Starl-ink • Over-the-Air Upgradeable Communicator Firmware. Fire provides full data reporting,in sole and dual path,as Remote ability for critical/mandatory updates,without a a primary or backup,to any central station of your choice, truck-roll without requiring any special equipment on premises. • Cost-saving models and plans for any code requirement. Ultra-affordable plans are available to meet various codes and requirements,with supervisory check-ins from 200 Substantial savings over monthly dedicated landline charges. seconds,to 5 minutes,to an hour.The units are very easily And,$100 saving incentive for system upgrades from old activated,plans and options are selected,and 24/7 account radios(all makes)and old POTS landlines,as well as new management is provided all through www.napcocomnet.com. installations connected by Napco StarLink Universal Fire Alarm verizon,/ Communicators • Sole Path Cellular and Dual Path Cellular&/or IP Models • Choice of plans(varies by model)-check-ins from 200 seconds,to 5-minutes to 1 hour,Verizon LTE Network • Patented Signal Boost1mand Dual Diversity Antennae for maximum signal acquisition&null avoidance, . ; receiving signals simultaneously on both antennae • Money-saving Tradeup incentive credit J • Bonus:Full High-Speed Napco Panel remote uploading/downloading • COMPLIANCES:NFPA72 Editions:2016,2013,2010, 2007;UL 864,9th Ed.,UL1610,UL985,UL1023,NYCFD; CSFM;LAFD StarUnk: n NFPX • Code-compliant standard or mercantile metal models(right and left respectively). 0 i," ta r Fs Commercial Fire'Alarm Cellular Wbr Ip connlinElic)AL F>IRi:CELLULAR&IV frre Alarm LTE CornmunlcatorsY -Y StarLink Fire Specifications Ordering Information STANDARD MODELS: COMMERCIAL FIRE SOLE PATH CELLULAR& • Advanced LTE Dual Diversity Antennae for optimized DUAL PATH CELLULAR&/OR IP("I"MODELS):* performance SLE-LTEVI-FIRE Dual Path Communicator,Cellular&dor IP, • Durable ABS plastic housing includes three keyhole slots for connected by Verizon LTE',ABS.Low current draw,panel- mounting(for commercial application,aligns with triple gang powered technology'(powered by control panel) boxes) SLE-LTEV-FIRE as above, but sole path cellular model • Panel Powered Technology'(powered by panel),Low current SLELTEVI-CFB Commercial Fire Dual Path Mercantile model draw,71 mA standby,200mA transmit in red metal housing on LTE,Verizon LTE Network,powered • Dimensions:5-3/8"x 7-7/8"x 1-7/8"(HxWxD) directly from control panel • Weight:13.5 oz SLETEVI-CFB-PS Commercial Fire Dual Path Mercantile model • 3 LED Indicators-Green,Signal Strength;Amber-Busy/ in red metal housing, LTE,Verizon LTE Network. Direct 120VAC Activation;Red-Trouble Powered(w/provisions for backup battery/charger).Or, • Patented Signal Boost1m signal amplification circuit and high- Optional TRF12 plug-in transformer may be used,where codes permit gain performance antennae p ._, • Operating Environment:0 to 49°C(32-1200F),up to 93% ACCESSORIES: :,m humidity(non-condensing) Free Commercial Fire Tradeup Trifold _ - - • 12V-24V Universal FACP Support,auto-current sensing. Brochures/Mailers/Stuffers(A720)for new g Support all brands communicating in Contact ID and 4/2 and existing fire accounts SLE-ANTEXT75 Optional extended antenna with MERCANTILE MODELS(similar to above,with): 75'cable(new conical shape) • Locking Metal Enclosure with Hinged door& 2 key-slots for SLE-ANTEXT50 As above,with 50'cable wall mounting(LED indicators,inside) SLE-ANTEXT30 As above,with 30'cable • Dimensions: 9-5/8"x 11-3/4"x 3-3/8"D(HxWxD) SLE-DLEXT Optional,as above,for downloading,extends distance • Weight:8 lbs(max.,power supply models) to Napco panel up to 100' • Electrical Ratings for 120VAC,60Hz TRF12 Optional Plug in AC Transformer,16.5V/20VA(use is • For Models with Power Supply: subject to local code compliance) • Input Voltage: 120VAC Nominal SLE-DLCBL Optional High-Speed Napco Panel Up/download cable • Input Current:400mA maximum • Maximum Charging Current: 200mA _ • Electrical Ratings for+12V ' New! FireLinlC Integrated Fire Alarm Control • For Models without Power Supply: i . Panel w/Starl-ink Fire LTE Built in • Input Voltage: 11-15VDC(power-limited output from listed o Y` Award whining FL-FRCP-LTEVS control panel) *, Firewoif 8 Zone 24V Conventional • Input Current:71 mAwith peak RF transmission current of z°18 Commercial Fire Alarrra,Control 200mA i Panel with onboard StarLink Fire I' Sole Path,Verizon LTE Cellular • Electrical Ratings for the IN 1 Burg/Fire Input: I : AEarm Communicator,and integral ( menu-driven LCD annunciator,w/ • Input Voltage:9-15VDC 4amp,24v power supply.optionally expandable up to 32 points/zones via • Maximum Input Current:Up to 2mA from FACP NAC circuit { commercial addressable,wireless or • Electrical Ratings for IN 2 and IN 3: • conventional fire devices(2 onboard NACs providing up to,4A notification I • Maximum Loop Voltage:15VDC power).-Locking,mercantile.red• e enclosure,(surface or,flush mount*) 1 Maximum Loop Current: 1.2mA # removable 16"xi7"door with { • Electrical Ratings for 3 PGM Outputs: 14.25"x16"base.Houses 1`6Ah battery backup • Open Collector Outputs: Maximum voltage 3V when active; 15V maximum when not active • Maximum PGM Sink Current:50mA mount �StarUnk• Operating Environment 0 to 49°C(32-120°F),up to 93% Rtw a humidity(non-condensing) COMMERCIAL FIRE CELLULAR&IP • 12V-24V Universal FACP Support,auto-current sensing. 333 Bayview Ave.,Amityville, 1- 89-92 USA pP g 1-800-645-9445 •Fax:1-631-789-9292 14 NEPA Support all brands communicating in Contact ID and 4/2 www.napcosecurity.com StadinkStadinkFire,PreUnk SignalBoost,PaneIT weredTedmobgy,Gemini&Gemini CommerdalaretrademakofNapco.Ver¢on,LTE,mareVademarhoftheimspecM companies.'StarUnkoffersfufi data cmeragein US fromNrtualyall panelbrandsreporfingin ContadlhWZ • WMgdeUi onthe5WAtadeupincentkeseearirieunderV/Aw,w.mpcoseatd.mTo shdinkl9adinlAgupgrade/fftmsubjedtodtangew/opdorrwfim.LlElitespandairrsarebasedm&Rafome¢3VeimrPrdftbasedontheRootMtaUSNafiodRo�ReportlH2O17. ©NAPCO,NAPCO Security Technologies Inc(NASDAQ:NSSQ A7342018.9 0 SYS TEM ASENSOR@ r C01224T and C01224TR -- - -� Carbon Monoxide , ,, 1 Detectors � with RealTest'Technology The System Sensor CO1224T and CO1224TR(round) Carbon Monoxide(CO)Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features With RealTest®technology,the CO gas sensing cell used in • RealTest@ enables a functional test using canned CO the C01224T and C01224TR CO detectors can be tested using a CO gas agent,fully meeting the requirements of NFPA 720:2009. • Full compliance with UL 2075 Simply put the detector into RealTest mode,spray a small amount • A code-required trouble relay of CO into the detector per the installation instructions,and within • Wiring supervision with SEMS terminals seconds the detector will alarm,indicating successful gas entry.(See the reverse page or the user manual for complete instructions.) • A six-year end-of-life timer • 12/24 VDC When dangerous amounts of CO are detected,the C01224T and • A low current draw of 20 mA in standby and 40 mA in alarm C01224TR detectors alert residents by sounding and flashing a temp 4 signal alarm.With 24/7 central station monitoring,residents • Versatile mounting for wall and ceiling are guaranteed protection whether they are away from home, • Accurate and reliable electrochemical sensing technology sleeping,or already suffering from the effects of CO. • Optional CO-PLATE CO Detector Replacement Plate to upgrade The C01224T and C01224TR are designed for system operation. previously installed competitor detectors to the C01224T These detectors are fully listed to UL 2075 and offer a code- required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.The C01224T and C01224TR also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision.With a low current draw,these detectors enable more devices to be connected to the panel,limiting the need to purchase extra power supplies or more expensive panels.As 12/24 VDC detectors,the C01224T and C01224TR will operate on most industry security and fire alarm control panels. Agency Listings @ 0 ( LISTED & E307195 E304075 5276-1653:0194 • C01224T and C01224TR Carbon Monoxide Detector Specifications Carbon monoxide(CO)detector shall be a system-connected System Sensor model number C01224T or C01224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct(surface)mount to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide dual-color LED indication that blinks to indicate normal standby,alarm,or end-of-life.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the panel.When the detector gives a trouble or end-of-life signal,the detector shall be replaced.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time specified by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts per million(ppm),as verified by a Nationally Recognized Test Laboratory, Electrical Specif!cations, Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA(75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size:C01224T Length:5.1 in,Width: 3.3 in,Height:1.3 in C01224TR Diameter:6 in,Height: 1.3 in Approximate Weight CO1224T:7 oz;C01224TR: 11 oz Operating Temperature Range 32oF to 104°F(0eC to 40°C) Operating Humidity Range 22 to 90%RH Input Terminals 14 to 22 AWG Mounting Single-gang back box;surface mount to wall or ceiling Operation Modes •. ..• GroeftLED, Bed LED Sounder Normal(standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattern Sound in temp 4 pattern RealTest®Feature: The System Sensor C01224T and C01224TR Carbon Monoxide Detectors with RealTest enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. Push and hold the Test/Hush button for Spray canned CO agent into Verify CO sensing at the two seconds to enter RealTest mode.The the detector. control panel.The detector will green LED will flash once every second automatically exit RealTest alarm to indicate Rearrest mode has started. mode after about 20-60 seconds. NOTE:Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes(except in RealTest mode). Trouble Feature: When the detector is in a trouble condition,it will send a trouble signal to the panel. r` End-of-Life Timer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to the panel to indicate it is time to replace the detector.An electrochemical CO detector lifespan is about six years.The detector must be replaced by the date marked on the inside of the product. CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint(when necessary)of previously installed competitive carbon monoxide detectors that require replacement. Ordering Information CO-PLATE DescriptionPart No. C01224T 12/24 volt,4-wire system-monitored carbon monoxide detector with RealTestO Technology C01224TR 12/24 volt,4-wire system-monitored round carbon monoxide detector with RealTestO Technology CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors as necessary ���� 3825 Ohio Avenue•St.Charles, IL 60174 02012 System Sensor. orcom �� ,� Phone:800-SENSOR2•Fax:630-377-6495 Ptorcurre tprd ct odtlonssrmati to changewtheltestve.Ynofthisdatasheet for current product infortnadon,including the latest version of this data sheet www.systemsensor.com SCOS00100•4112 FIRE ALARM SYMBOL LIST ELECTFICAL FFACPJ I aeu.wcanm PA'6 NOTES FM p saEuwuxxuN11N6 QI lJA.'AkINi fO DE PKfN.LEDACCLRDPI(.fO tlk LAIESfO:VKILN Lf nE NE.C,PNDN.I.OIFER SECipP5 GP nE N.FPA.S1N10,12Di. QN.Lcmir.for-mET 1E5fakE L•F 0.'aNDS.akrEhN95rILkYS. Ep 1 oaaeA:rmwvuiRuen 07U.1ER/M1NfI0DS PRE TO Gk SUkKv1iEDINALEtREiENfhME a'GKihvD FRE SY>fE175<GfSJ FaaE fO POJrfRPL+nE EalPAknf. MOUNT DN 1 09 EEeernveNDlvttlKsm%i vm, HORN/STROBE BOROY Of p ew cDB aw moE®r�wa ® CEILING MOUNTED caUXO THE - FQ D Y Qr01'COA1PaEIIfVsee ocrHl.slfxralo Paa��r,A�rezt~L. ,T7 00fl%T� Oa scrcrrwwcerolevEerrcoNoagP cRawnr. HORNLSTROBE 1 � maw W V S 3 PnrouPeEADErecrcR�A.wniwreoPn'Peo,�aun>.RDucr. STRO E ONLY 'X 0 mR�ear Rm�w a >'m Z co B 1 isuTwmarma3t 1O.aN Q Y y A TM" .—V °°- ° Lk�EwAawrrlrrlsnvcncnlsnvorr�ovmc+ds,carxrc�.svc�r>;ra.unalEt:l w ® 0 aE�e.rwwE m m 0 �/ �T-BAR/BACK-SBO%'110UNTING MANUAL PULL STATION© p,Y TAILS SCALES NTS fOMC'IDNffMYfQ',FN.SEOL^Rh15. 0 0 �E� �� W 0 r Q a1CWfING FEILNFi. � ® 1 rtN6BirAM41 OSAmn��m�OBAcO �D-, A),VNNNLPU5fATV.A 46'00nrez D_ I)VI'M.eO"fO nF PCITOM OF ilk DEVICE CR b"rtWV nE CELPIi ® 1 B1fA1B1TNFH1&CIOI � 0 ® EyAmoaq%5 fom vairroll FREED. FlRE ALARM DEVICES ® g —rwr.ai — ° (- MOUNTING HEIGHTS � 1 NIOENMmEFIMBfOs181B1wr�sr © 1 a.wmurPr a x�o SEOUENCE OF OPERATIONSBMW ®m 121uawraxo:meoE�rsrw ❑ NOTES p- /i✓ ..�-: `I ❑ L__JLi rFJ All B 6 B 6 B b 615&tlY °"ee�reoirmwn O.� � )( � c.�ma cl�mn�cn' `x4 ¢ �/ AAa11Mek we+40aaaw o3AINLarA1Q!em.ra'Aaon J/ �IpM `Q�� 1w.YaRmBL I'� , - '� �.mwAPMtuceuimw � ! � 5 2nd Floor Plan B NAC CKT-1 i I STROBE SHALL HORNISTROBE g ,� REMAIN ON SHALL SOUND UNIILPANELIS TEMPORAL-3 RESEL HORN - PATTERN NAC CKT-2 SHALL BE �n n! e< ^--_ saElNCEaeLI=_ A A F 1 1 1 1 AKg- 1STFLOOR IG444I A%2EU EU H—H EU wz 1 n 1 st Floor Plan s„= Q S Z '^ g ADDRESSABLELOOP N ; w g FIREALARYw"EsaE: C7w n VS-1 RD a:1 LrzTWISTED FPLP _ I�^00 Axz B:11QTwISTED FPLP FACP ALLw1RETOBEUSTEO FOR FIRE v ALARM USEAS PER N.EC. CELLAR To DEDICATED ❑ 12OVAe CIRCUI1 Cellar Plan a Q RISER DIAGRAM FIRE uM.PE.v mm u 5„E'T This MEF raa FIRE Mins AL USE orvEr FA-1 FIRE ALARM SYMBOL LIST C C� FACP 1 FARE ALARM CONTROL PANEL KIDDE EDWARDS VS-w N01�5 FAA O FSE ALARM ANNUNCIATOR PANEL KIDDE EDWARDS 0 AU. WIFING 1'0 P3 IN5f&LFP ACCOFPIN61'O TNS I AT�5f MV15ION OF TNS N,r,C, ANP Al 011 FF 5�C110N5 OF TNF N,F,P.A, 5fANPAFP5, R-CD-CR a 1 DOUBLE Acmm MANUAL PULL STATION KIDDE EDWARDS z 02 Al CONPUCTOt;S MU51 T�51 Ff;FF 0F GPOUNPS, Op�NS ANP SNOt?1"5, GSA-M270 Q ALL tFMINAVON5 AI?� 1'0 PF 5UP�FVI5FP 13Y A VT, 5�NfA11V� OF 6Al?I.ANP FII 5Y5tM5 (G,F,5,) FF?101?1"0 POWEpING TNS �QUIPMFNf, AHC-ABOVE 1 0T0E� SMOKE KIM EDWARDS KI-� HORN/STROBE �� MOUNT ON ® FFCOMWNP WRING A5 5NOWN, BOTTOM OF 0 O DETECTOR KV� DROP ACOUSTIC TI CEILING MOUNTED CEILING TILE AHC=ABOVE CEILING Q 4-- KIDDE 0 FOF COMPONFNf WIFIN6 51T P�f& 5HFFf ANP PACKAGING MAVIAL, s� O DUCT SMOKE DETECTOR , ' (a L S=SUPPLY SIDE GS0 BACK BOX w/ T— AR © 5HOF 12FAWIN65 PO NOT PFFICf CONPUIf FUN5 OF, QUM-fl ', D° �D HORN/STROBE S W U N >-- HORN STROBE � 1 NOTES, IN5fAl PRA P�WOF5 A MINIMUM OF 31 FPOM ANY AIL? PMctR-VM STROBE ONLY UCE, STROBE ONLY �° i � a) O �y � 1. T—BARS REQUIRED FOR CEILING MOUNTED SMOKE POTM ty Z DETECTORS AND NOTIFICATI❑N APPLIANCES IN AREAS ® WIOp 1'0 FLACWFNf OF CEILING MOUNTEP 01; PUCE MOUNtP 5MOKf 12 TtCfO1?5 OF, NEAT P�T�C1"OpQ5 1 VIBRATING EXTERIOR BELL MBA-8-24 -`1 WITH SUSPENDED CEILINGS, IJ 2, ALL EQUIPMENT SHALL BE INSTALLED IN COMPLIANCE WITH ALL LISTED DISTANCES, LOCAL ORDINANCES AND FFVVW MOUN1IN6 IN5TPUC11ON5 ANP FF,�CAU110N5, CONfACf G,F,5 FOL? IN5f&LA110N P VIEW _ ADM KIDDE '� Co C MANUAL PULL STATION 0 o O ADDRESSABLE RELAY MODULE Q dam- , REC❑MMENDATI❑NS, ONFPA-72 BAR/BACK BOX MOUNTINGKIDDE EDWARDS E TAILS S C A L E) NTS 1'0 AVOID NU15ANCF OP, FAL5F ALA2M5, - }(R' O REMOTE LED GSA-LED W O E ca °0 0U) O �9 MOUNTING N�IGN15; DIM 1 WATERIR_OW/TAMPER MONITOR MODULE KIDDE EDWARDS GSA-WTM or GSA-CT2 O MANLIAI, t'UL� 5TA110N5, 48" 10 C�NV wF 1 sPRwKLER WATERFLOW SWITCH FURNISHED BY 6) VISI.K: 80'' TO TNS 130ffOM OF TNF P�VICF O1P, 6" PF0W TNF CHLING, OTHERS� 0 TS 1 SPRINKLERF�SHED BY TAMPER SWITCH OTLL Oo WCT LOCAfION5 fO P3 V�FIFW IN THS FIFLI2, FIRE ALARM DEVICESKIDDE AIM 3 SINGLE INPUT MONITOR MODULE EDWARDS I MOUNTING HEIGHTS FURNISHEDAES 1 KITCHEN HOOD EXTINGUISHING SYSTEM OTHERS BY DICT 1 CELLULARCOMMUNICATORSNAFM TARLINKDIALER SEQUENCE OF OPERATIONSCo 2 CARBON MONOXIDE DETECTOR SY Wulff NSOR a �a � a �} W S � y o 18 � 6 NOTES CENTRAL STATION ALARM SERVICE TO RECEIVE SEPARATE fEl � - ' O DISTINCT SIGNAt_S AS FOLLOWS N4 ttitl.ck-cotchbgue Dining Room I ~ �– A]FIRE ALARMy ,• 's tJr.SS I"Rl f�.c.?�..liot4ol la a I— _ _J B)TROUBLE SIGNALS NOTETOPLAN EXAMINER: jzd A 10 YEAR BATTERY POWERED C)SUPUMSORY SIGNALS(TAMPER SWITCH) +5�� CARBON MONOXIDE DETECTOR U x• "i p�, d SHALL BE INSTALLED BY OTHERS 4t, if, ON THE 2ND FLOOR ONLY. Lady a a ;` C F J D)SUPL�iVISORY SIGNALS(CO DETECTOR-GAS ALARM) L,rt wChurch, I I Kitchen ] na F � � F � F � � � ��f F� I^rl,", • �I;I,��a LovLt. . ' a J , c y e. Mattgtuck eaEt tSffD1(f r'��t* X X X X ACTIVATES HORN AND STROBE BY MAIN ENTRANCE DOOR " Y 0 X X X X X X X TRANSMIT SK14AL TO CENTRAL STATION al a SaaFi z Living I Bed Roo - O Bedroom C C ACTIVATES CONTROL RELAYS FOR FAN+MUSIC SHUTDOWN > £ f LLJ f• X ACTIVATES EXTERIOR VIBRATING BELL k c 2nd Floor PIan SCALE:8"=,'-0" TIE-IN TO ADJACENT TENANTS FIRE ALARM SYSTEM E N NOTE TO PLAN EXAMINER: fi CS p�a•� \ IT IS NOT KNOWN AT THIS TIME ,,. ' Map data C2022 IF TAMPER SWITCHES WILL BE PROVIDED BY THE RPZ ON EXTERIOR ��5 N KEYPLAN ( N . T. S. ) BCE ;. UP NEW Fir MI ler Riser y N n — NEW NAC CKT-1 �j Z LLJ Y NOTE TOP N XAXAMINER: y Class K i� � > � THE BUILDlh G V ILL BE FULLY NEW a. ire Extinguisher WET SPRIN LE ED. E) ,.- STROBE SHALL Q Q w 0 0 HORNISTROBE 95 1 REMAIN ON n n U SHALL SOUND � ED � TEMPORAL-3 UNTIL PANEL IS Ladies Lay. Men's Lay. Kitchen RESET. HORN JA E z N,o/ III PATTERN NAC CKT-2 SHALL BE WF TS 1 c0 � o J � Front Entrance SILENCEABLE. Ax2 r Amo1Ax2 � N oM �J CCOIJ F DIM AIM � w r' I � w N cD M LJ"U ❑LB ❑ ��; 1 ST FLOOR w z N a w �+ /\ / NN ❑ ❑ 3UNM — E to J = w N ILLI F MjN= f UW 15:, Q �z Dining Room WF-1e / I f-- >- U ❑ ❑ ❑ ❑ ❑ ❑ D[]H D Box W Z Z Z ❑❑❑ [:][:][:][:]ElP� 1 1 S AIM � 1st Floor Plan SCALE:8'=,'-o" Aem V)Z ADDRESSABLE LOOP Q' B w � WH FACP DACT UP S NEW/NEW J rr hh Fri-1�(, ✓ NEEWFIRE ALARM WIRE SIZE: V w Ln o. e 0 A: 18/2 TWISTED FPLP 00 VS-1 RD B: 1412 TWISTED FPLP WIRELESS WIRELESS Ax2 ` COMMUNICATOR IS COMMUNICATOR 5; 00 APPROVED BY U.L. ro, ❑ WHICH MEETS DACT FACP ALL WIRE TO BE LISTED FOR FIRE W i NEPA-72 CODE. ALARM USE AS PER N.E.C. Ax2 Q U STORE ROOM umaces CELLAR EW Yoly TO W--INDEDICATED C0COOLU .a. r? w LER 0 120Vac CIRCUIT SF O Cellar Plan SCALE...1"=1,_o„ Z PROF I RISER DIAGRAM FIRE ALARM PLAN NO SCALE SHEET THIS AREA FOR FIRE MARSHAL USE ONLY FA - 1 ISI YS I F New York State insurance Fund PO Box 66699,Albany,NY 12206 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) D D A A A A A A 562457472 USI INSURANCE SERVICES LLC 725 RXR PLAZA EAST TOWER Imil 0j UNIONDALE NY 11556-3645 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER RIARK CORP T/A TOWN OF SOUTHOLD ABT DESIGN&FIRE PROTECTION BUILDING DEPARTMENT 1724 CHURCH STREET TOWN HALL HOLBROOK NY 11741 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 11169034-4 387856 02/03/2022 TO 02/03/2023 2/2/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 1169 034-4, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/IWWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE SUR NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 889297524 U-26.3 Client#:776522 RIARKCOR ACORD,,,, CERTIFICATE OF LIABILDATE(MMIDD/YYYY) ITY INSURANCE 5/02/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Yarden Bleicher NAME: USI Insurance Services LLC PHnNE AX eLo Ext):516419-4000 c ,No 725 MR Plaza,East Tower ADDRESS: Yarden.Bleicher@usi.com Uniondale,NY 11556 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Admiral Insurance Company 24856 INSURED INSURER B:Utica National Assurance Company 10687 Riark Corp.dba ABT Design 8r INSURER C Fire Protection INSURER D: 1724 Church Street INSURER E: Holbrook,NY 11741 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR INS WVD POLICY NUMBER MM/DDIYYYY MM/DD/YYYY A X COMMERCIAL GENERAL LIABILITY CA00004188401 5/15/2021 05/15/2022 EACH OCCURRENCE $110001000 CLAIMS-MADE 51 OCCUR PREMISES Eaoccurrence $300,000 X PD DED$10,000 MED EXP(Any one person) s5,000 PERSONAL&ADV INJURY $1,000000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERALAGGREGATE $2,000,000 POLICY X1PRO [7] ECT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ B AUTOMOBILE LIABILITY 4749790 4/27/2022 04/27/202 COMBINED SINGLE LIMIT Ea accident 1,000,000 ANY AUTO BODILY INJURY(Per person) $ OWNED X SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ X HIRES ONLY X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY Per accident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION PEROTH- AND EMPLOYERS'LIABILITY Y/N ISTATUTr OFFICERO/MEMBER EXCLUDED?ECUTIVE❑ N/A E.L.EACH ACCIDENT $ (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. Town Hall Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S35823618/M35801128 JYPCW FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the.time of system acceptance and approval. 1. Protected Property Information Name of property: Poke Berry Cafe Address: 141 Pike Street Mattituck Description of property: Restaurant/Bar Occupancy type: Public Assembly/retail Name of property representative: Marco(Owner) Address: Phone: Fax: E-mail: Authority having jurisdiction over this property: Town of Southold Phone: Fax: E-mail: 2. Fire Alarm System Installation,Service, and Testing Information Installation contractor for this equipment: GARLAND FIRE SYSTEMS INC. Address: 33 TEC STREET, HICKSVILLE NY 11801 Phone: 516.223.3189 Fax: 516.223.3126 E-mail: OFFICE@GFSFIRE.COM Service organization for this equipment: GARLAND FIRE SYSTEMS INC. Address: 33 TEC STREET,HICKSVILLE NY 11801 Phone: 516.223.3189 Fax: 516.223.3126 E-mail: OFFICE@GFSFIRE.COM Location of as-built drawings: BY FACP Location of Historical Test Reports: Location of system operation and maintenance manuals: BY FACP A contract for test and inspection in accordance with NFPA standards is in effect as of 12/2022 Contracted testing company: _Garland Fire Systems _.. Address: 33 Tec Street Hicksville, NY 11801 Phone: 516-223-3189 Fax: 516-223-3126 E-mail: office@gfsfire.com Contract expires: Contract number: Frequency of routine inspections: 3. Type of Fire Alarm System or Service NFPA 72®, Chapter Reference of System Type: Name of organization receiving alarm signals with phone numbers(if applicable): Alarm: CMS Phone: 631-289-2800 Supervisory: CMS Phone: 631-289-2800 Trouble: CMS Phone: 631-289-2800 Entity to which alarms are retransmitted: N/A Phone: Method of retransmission of alarms to that organization or location: N/A NFPA 72, Fig. 4.5.2.1 (p. 1 of 5) Copyright©2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. t ' If Chapter 8,note the means of transmission from the protected premises to the central station: ®Digital alarm communicator ❑McCulloh ❑Multiplex ❑2-way radio ❑ 1-way radio ❑N/A If Chapter 9,note the type of connection: ❑Local energy ❑Shunt ❑N/A 3.1 System Software Operating system(executive)software revision level: Site-specific software revision date: Revision completed by: 4. Signaling Line Circuits Characteristics of signaling line circuits connected to this system(see NFPA 72®, Table 6.6.1): Quantity: 1 Style: Y. Class: B 5. Alarm-Initiating Devices and Circuits Characteristics of initiating device circuits connected to this system(see NFPA 72®, Table 6.5): Quantity: Style: Class: 5.1 Manual Initiating Devices 5.1.1 Manual Pull Stations Number of manual pull stations: 1 Type of devices: ®Addressable ❑Conventional ❑Coded ❑Transmitter ❑N/A 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Number of smoke detectors: 1 Type of coverage: ❑Complete area ®Partial area ❑Nonrequired partial area ❑N/A Type of devices: ®Addressable ❑Conventional ❑Coded ❑Transmitter ❑N/A Type of smoke detector sensing technology: ❑Ionization ®Photoelectric 5.2.2 Duct Smoke Detectors Number of duct smoke detectors: Type of coverage: Type of devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter ®N/A Type of smoke detector sensing technology: ❑Ionization ❑Photoelectric 5.2.3 Heat Detectors Number of heat detectors: Type of coverage: ❑Complete area ❑Partial area ❑Nonrequired partial area ®N/A Type of devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter ®N/A 5.2.4 Sprinkler Waterflow Detectors Number of waterflow detectors: 1 Type of devices: ®Addressable EJConventional E]Coded E]Transmitter ❑N/A 5.2.5 Alarm Verification Number of devices subject to alarm verification: Alarm verification on this system is:❑Enabled ®Disabled ❑ Set for seconds 6. Supervisory Signal-Initiating Devices and Circuits 6.1 Sprinkler System Number of valve supervisory switches: 3 Type of devices: ®Addressable ❑Conventional ❑Coded ❑Transmitter ❑N/A NFPA 72, Fig.4.5.2.1 (p. 2 of 5) Copyright©2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. 6.2 Fire Pump Type of fire pump: ❑Electric ❑Diesel Type of fire pump supervisory devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter ❑N/A Fire Pump Functions Supervised ❑Fire pump power ❑Fire pump running ❑Fire pump phase reversal ❑Selector switch not in auto ❑Engine or control panel trouble ❑Low fuel Other: 6.3 Engine-Driven Generator Type of generator supervisory devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter ®N/A ❑Engine or control panel trouble ❑Generator running ❑Selector switch not in auto ❑Low fuel Other: 7. Annunciators 7.1 Annunciator 1 ®Local ❑Remote Type:o Addressable ❑Directory ❑Graphic ❑N/A Location: on FACP in Basement 7.2 Annunciator 2 ❑Local ❑Remote Type:❑Addressable ❑Directory ❑Graphic ❑N/A Location: 7.3 Annunciator 3 ❑Local ❑Remote Type:❑Addressable ❑Directory ❑Graphic ❑N/A Location: 8. Alarm Notification Devices and Circuits 8.1 Emergency Voice Alarm Service Number of single voice alarm channels: N/A Number of multiple voice alarm channels: N/A Number of speakers: N/A Number of speaker zones: N/A 8.2 Telephone Jacks Number of telephone jacks installed: N/A Number of telephone handsets stored on site: N/A Type of telephone system installed: ❑Electrically powered ❑Sound powered ❑N/A 8.3 Nonvoice Audible System Characteristics of notification device circuits connected to this system(see NFPA 72', Table 6.5): Quantity: . 1____..­_..___ - Style: ---Y— — -- .. .. _,....__ Class: B 8.4 Types and Quantities of Nonvoice Notification Appliances Installed Bells: With visual device: Horns: With visual device: 1 Chimes: With visual device: Bells: With visual device: Visual devices without audible devices: 2 Other(describe): NFPA 72, Fig. 4.5.2.1 (p. 3 of 5) Copyright©2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. 9. Emergency Control Functions Activated ❑Hold-open door releasing devices ❑Smoke management or smoke control ❑Door unlocking ❑Elevator recall ❑Other 10.System Power Supply 10.1 Primary Power Nominal voltage: 120 Amps: 20 Overcurrent protection: Type: Breaker Amps: 20 Location(of primary supply panelboard): Next to FACP Disconnecting means location: Next to FACP 10.2 Secondary Power Location: in FACP Type: Battery Nominal voltage: 24 Current rating: 7 Number of standby batteries: 2-12vdc Amp hour rating: 7AH Location of emergency generator: N/A Location of fuel storage: N/A Calculated capacity of secondary power to drive the system In standby mode: 24 In alarm mode: 5 11.Record of System Installation Fill out after all installation is complete and wiring has been checked for opens,shorts,ground faults, and improper branching, but before conducting operational acceptance tests. The system has been installed in accordance with the following NFPA standards:(Note any or all that apply.) ®NFPA 728 ®NFPA 70®,Article 760 ®Manufacturer's published instructions ❑Other(please specify): System deviations from referenced NFPA standards: Signed: Printed name: Date: Organization: Garland Fire Systems Title: Phone: 516-223-3189 12. Record of System Operation All operational features and functions of this system were tested by or in the presence of the signer shown below,on the date shown below,and were found to be operating properly in accordance with the requirements of: ❑NFPA 72® ❑NFPA 70®,Article 760 ❑Manufacturer's published instructions ❑Other(please specify): ❑Documentation in accordance with Inspection and Testing Form(Figure 10.6.2.3 of NFPA 72®)is attached Signed: Printed name: Date: Organization: GARLAND FIRE SYS Title: Phone: 516.223.3189 NFPA 72, Fig.4.5.2.1 (p.4 of 5) Copyright©2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. 13.Certifications and Approvals 13.1 System Installation Contractor This system as specified herein has been installed and tested according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: GARLAND FIRE SYS Title: Phone: 516.223.3189 13.2 System Service Contractor This system as specified herein has been installed and tested according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.3 Central Station This system as specified herein will be monitored according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.4 Property Representative I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.5 Authority Having Jurisdiction I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications,its approved sequence of operations,and with all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: NFPA 72, Fig.4.5.2.1 (p. 5 of 5) Copyright©2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. Food Establishment Inspection Report Suffolk County Department of Health Services — Page 1 of 2 360 Yaphank Avenue Suite 2A Date: 04/05/2023 Yaphank,NY 11980 631-852-5999 www.suffolkcountyny.gov/health Establishment Name Establishment Address City/State Zip Code Telephone POOKABERRY CAFE 140 PIKE ST MATTITUCK,NY 11952 Facility ID# Permit Holder Purpose of Inspection Inspection Result FA0011567 POOKABERRY CAFE INC Reinspection/Follow-up Permit Issued Owner Owner Address Permit Restrictions Capacity POOKABERRY CAFE INC PO BOX 222, CUTCHOGUE NY 11935 seats Inspection Violations Comply By Date No violations cited. —Overall Inspection Comments OK TO ISSUE PERMIT.OK TO OPERATE WITH MULTI USE DISHWARE.DISHWASHER NOTED FUNCTIONING PROPERLY AT THE TIME OF INSPECTION.ALL HANDWASH SINKS WERE NOTED SUPPLIED WITH LIQUID SOAP AND PAPER TOWELS. Inspected By Michael Cromwell,San ID#963 DeltaTRAK Model 11050 used Inspection results are available online at https:Heco.suffolkcountyny.gov/#/pal/search Risk Factors cited in consecutive inspections may result in enforcement action,including a possible hearing and fine. THE FOOD MANAGER'S COURSE IS AVAILABLE ONLINE IN ENGLISH,SPANISH AND CHINESE! To register for the Food Manager's course,please visit https://apps2.suffolkcountyny.gov/Health/FdOnline/default.aspx. Suffolk County FMC App and SIRF self-inspection app for mobile devices are available for download from Google Play and the Apple Store. All food service establishment operators are required to post the following advisory on all menus(including website menus)and menu boards located inside or outside of the establishment:"Before placing your order,please inform your server if a person in your party has a food allergy". College,public and private school food operations are exempt. Effective Jan.1,2020 all drinking straws and stirrers must be provided in food establishments by consumer request only,and must be made of biodegradeable(non-plastic)material. Plastic drinking straws and stirrers may continue to be provided by request to consumers with a disability or medical condition. Effective July 1,2021 the use of latex products is prohibited in all food establishments. Further information at https://suffo[kcountyny.gov/Departments/Health-Services/Public-Health-Protection/Plastics-and-Latex-Laws Suffolk County Local Law 29-2009 amended Chapter 437(now Chapter 754)of the Suffolk County Code to prohibit"heating or ignition of an e-cigarette which creates a vapor"in all public places. The use of"E-CIGARETTES"IN ALL ESTABLISHMENTS WITH A SUFFOLK COUNTY FOOD PERMIT IS PROHIBITED,SUBJECT TO ALL PROVISIONS OF THE NY STATE CLEAN INDOOR AIR ACT AND SUFFOLK COUNTY LOCAL LAW. EMPLOYEE SICK POLICY WAS DISCUSSED DURING THE INSPECTION: Person in charge was reminded that all sick employees MUST be excluded from food service.No sick employee is permitted to return to work until they have been symptom-free for at least 24 hours;certain illnesses require that employees are tested prior to returning to work,even if symptom-free,or require further Department approval. Contact the Bureau of Public Health Protection for details. A log must be kept on-site documenting the exclusion of ill employees. L � APR 0 5 2023 ' �� .I Food Establishment Inspection Report Suffolk County Department of Health Services Page 2 of 2 360 Yaphank Avenue Suite 2A Yaphank,NY 11980 Date: 04/05/2023 631-852-5999 www.suffolkcountyny.gov/health Establishment Name Establishment Address City/State Zip Code Telephone POOKABERRY CAFE 140 PIKE ST MATTITUCK,NY 11952 Facility ID# Permit Holder Purpose of Inspection Inspection Result FA0011567 POOKABERRY CAFE INC Reinspection/Follow-up Permit Issued Owner Owner Address Permit Restrictions Capacity POOKABERRY CAFE INC PO BOX 222, CUTCHOGUE NY 11935 seats EE0000963-Michael Cromwell PETER MARCO PRESIDENT 'The items noted above are violations of applicable laws,rules and regulations found during an inspection of the operation of the facilities in this establishment which must be corrected as indicated.Failure to comply may result in the initiation of legal action against this establishment as provided for in Articles 2 and 13 of the Suffolk County Sanitary Code including a hearing,possible suspension of your food operation,and/or the publication of the violation and fines." 5062 4 STEVEN BELLONE GREGSON H.PIGOTT,NID,NIPH " SUFFOM COUNTY EXECUTIVE COMMISSIONER e SUFFOLKCOUNTY DEPARTMENT OF HEALTH SERVICES I' Johnson Controls 010 One Stanton Street,Marinette,WI 54143-2542 SA ohnson Tel+1 715 735 7411 wm.JohnsonControls.com Controls ij October 21, 2020 I � Subject: Tandoori Oven Protection Recommendation I i To Whom It May Concern, This letter is written to address ANS L's recommendation for protections of Tandoori Ovens. If the oven in question is fired by gas, and there are no lava rocks or ceramic briquettes utilized during the cooking process, the 1 N nozzle may be used based on protection for gas.radiant char-broiler protection. The IN nozzle should be positioned ov66ad and has a maximum dimension of 36" on the longest side and a total of 864 in2,when the nozzle discharge pattern is unobstructed. If the oven in question is fired by wood, the use of!the 3N nozzle will be needed utilizing the wood fueled char-broiler protection. The concepts of the recommended protection addressed above are not itested or listed since Tandoori Ovens are not recognized by U 1 as requiring protection or addressed in any test methods. Any protection chosen should be in compliance with all local codes and acceptable to the authority having jurisdiction. Sincerely, Corey Polzin Technical Services Manager— pecta azards, America I � II I I I I i SUFFO.LK. -COUNTY DEPARTMENT OF FIRE, .RESCUE AND E;MERGEN..CY SERVICES PORTABLE:FIRE- EXTIN.G.U-ISHER AND,AUTOMATIC FIREEXTINGUISHING SYSTEMS LICENSING BOARD .. ' C-ERTIFI.CATE ,0F REGI-STRATI;ON ��. -REGISTRATION t - 111 � - - - _ - • - .' ..- �wf, r``.•'� �� ��.:s= �•:Fa_I =tea �, .F� I'�F 11, EFFECTIVE DATE:,. 03/18/ EXPIRATION DATE: ,`03/31/2023 'R':.v.h ISSUED TO: NAME ;&p-Corp..' _ dbaBT Design-and Fire'P.�r_:otection ADDRESS: ,' ='t�: 1724 Church l treet Holbreo6k, NY 1,1,174 s " ENDORSEMENTS Portable Fire Extinguishers . RDry/Wet Cbei�nical Extinguishing Systems° This Certificate of Registration,Does.Not Ezciusiveiy-Recothmend the Bearer COMMISSIONER- _ CHIEF FIRE-MARSHAL q-KYL << . 4j FastWrap® XL f/ Commercial Kitchen Grease Duct R��S7�R Fire Protection Products Product Data & Installation Guide '�AslFkk 1. Product Description U` Thermal Ceramics new FireMaster® FastWrap XL is the thinnest and lightest flexible wrap material available that passes the ASTM - ,w l _ E2336 test standard required by the 2006 IMC and NFPA 96 for , reduced clearance enclosure materials used to provide 1 or 2 hour fire rating for kitchen exhaust ducts. The FastWrap XL core blanket is manufactured using Thermal Ceramics' patented SuperwoolO fiber, a 2000°F rated, non-com- bustible, alkaline-earth silicate wool with low biopersistence. FastWrap XL is the product of extensive research and development resulting in break-through improvements in fiberization technology —, with significant enhancements in thermal properties beneficial to fire protection applications. FastWrap XL when used in combination _ with an approved firestop sealant provides an effective through -- penetration firestop in rated floor and wall assemblies. FastWrap XL is UL Classified and is part of UL's Listing and Follow-Up Service 4. Performance Specifications Program to ensure the consistent quality essential to the critical Reference Standard Standard No. Performance nature of this life-safety application. GreaseDuct Enclosure Product Features System ASTM E2336 Pass •Approval as a 1 or 2 hour shaft alternative in kitchen grease duct Section 16.1 - Non- applications Combustibility ASTM E136 Pass •Zero clearance to combustibles at any location Section 16.2-Fire •Thin and Lightweight at 1X inch thick, 6 pcf density Resistanance (wall) ASTM E119 Pass •Contours easily to complex duct designs • Butt Joints on inside layer to save labor and material Section 16.3 - ASTM C518 Pass • Fully foil encapsulated for fast and clean installation Durability Test •Completely inorganic and non-combustible Section 16.4 - ASTM E2336 Pass •Contains 2000°F rated fibers for added safety margin Internal Fire Test • Contains no low temperature mineral or glass fibers Section 16.5- Fire •Wide variety of through penetration systems Engulfment(duct) ASTM E814/E119 Pass • Resistant to mold growth (ASTM D6329) • Extensive Listings and detailed installation instructions Surface Burning Characteristics • Recognized and accepted by inspectors requiring less job-site Flame Spread engineering judgments (foil/blanket) ASTM E84 5/0 •Available in space saving 50 and 100 square foot rolls for optimal Smoke Developed job-site storage (foil/blanket) ASTM E84 5/0 •Available in 48 inch widths for less joints and installation labor Thermal Resistance 2.Applications (R-value) ASTM C518 (70F) 4.2 per inch •Applied in 2 layers to provide 1 or 2 hour fire protection to grease Mold Growth (75% ducts exhausting Type 1 hoods per IMC 2006,NFPA 96 and 2006 humidity) ASTM D6329 Resistant IAPMO UMC Mold Growth (95% ASTM D6329 Resistant 3. Physical Characteristics humidity) Duct FireMaster 5. Listings/Building Code Reports Fire Protection Unit Size Units/Wt./ Product ctn. ctn. Listed Uses Agency Listing Grease Duct Enclosure System (Zero UL G18 FastWrap XL Roll 1X'x 24"x 25' 1 37.5 lbs. Clearance)-AC101 (ASTM E2336) Grease Duct Enclosure System (Zero ICC-ES* ESR 2213 FastWrap XL Roll 1X'x 48"x 25' 1 75 lbs. Clearance) -ASTM E2336 Through Penetration FireStop System UL C-AJ-7119 FastWrap XL Collar Roll 1W x 6"x25' 4 37.5 lbs. _ASTM E814/UL 1479 Color White blanket with silver foil encapsulation *International Code Council -Engineering Service _M Morgan crucible Thermal Ceramics 6. Storage: C. 2 & 3 Sided Wrap Installation (Figure 1) FastWrap,,XL must be stored in a dry warehouse environment on When space does not allow for a complete wrap applied to the duct pallets. Pallets should not be stacked. on all four sides,the FastWrap XL is approved for 2 or 3 sided instal- l. Installation lations with mechanical attachment to a concrete or CMU assembly. FastWrap XL shall be installed by a qualified contractor in accor- The FastWrap XL is installed on the 2 or 3 sides of the duct as dance with manufacturer's instructions and referenced standards. described in one of the installation methods described in sections A See figures 1 to 5 for complete details. or B with the starting edge of the blanket attached to the concrete or CMU assembly and then wrapped around the duct until the other Materials and Equipment: end can be affixed to the other concrete or CMU assembly, thus • FastWrap XL blanket encapsulating the duct with insulation around all accessible sides. •Aluminum foil tape The blanket is to flange out onto the concrete or CMU assembly. It • Minimum X"wide filament tape (optional) shall be secured to the adjoining assembly with min 3/,s"diameter,4" •Carbon steel or stainless steel banding material,minimum'z'wide, long concrete anchors, footed to a minimum 134" wide x 3/,6' thick minimum 0.015"thick,with steel banding clips steel strip/strap with pre-drilled holes spaced a maximum 10" on • Hand banding tensioner and crimping tool center. The steel strip is to be placed around the entire perimeter of • Minimum 12 gage steel insulation pins;steel speed clips,minimum the duct in the exposure area. The FastWrap XL insulation wrap is 134"x 134"square or 134"dia., or equivalent sized cup-head pins; secured to the duct with minimum W wide steel banding 1034" cen- • Capacitor discharge stud gun ters. The ends of the banding are to loop into the steel strips/straps • FireMaster F2-HT-XL3 Prefabricated Door or Field Fabricated that foot the blanket to the concrete floor or wall, and tightened Door Hardware down. The trapeze support system may be incorporated within the •An approved firestop sealant wrap system. General. D. Mechanical Attachment Methods for Insulation Wrap To minimize waste, FastWrap XL blanket should be rolled out tautly I. Banding (Figure 2)- Minimum 34"wide carbon steel or stainless before measuring. Cut edges of the blanket shall be taped with alu- steel banding, 0.015" thick, is placed around the entire perimeter of minum foil tape to prevent exposed edges of the insulation from the insulated duct with maximum 1034"spacing centers and 134"from wicking moisture from condensation or grease from a compromised each blanket edge or 134"from each collar edge when using the butt leaking duct joint into the material and causing degradation of the joint and collar method. When banding, filament tape can be used fire barrier. Overlaps are used to block heat transfer in the event of to temporarily hold the blanket in place until the banding is applied. duct deformation resulting from thermal expansion. FastWrap XL The banding is placed around the material and tightened so as to blanket may be installed with either a mechanical banding system or firmly hold the FastWrap XL in place against the duct, but not cause insulation pins and clips (see Mechanical Attachment Methods any cutting or damage to the blanket. below and figures 1 and 2). Support hanger systems do not need 2 pinning (Figure 3)- For duct spans 24"or larger, min. 12 gage, to be wrapped provided that the hanger rods are at least a minimum 5" long steel insulation pins are welded to the duct in columns of V diameter and spaced a maximum of 60" on center along the spaced 12" apart, 6" - 12" from each edge and on 1034" centers length of the duct, and the angle iron is a minimum of 2" x 2"x '/8" along bottom horizontal and outside vertical runs to prevent blanket or SMACNA equivalent support system (SMACNA band strap sup- sag. Pins are also required,1"from the end of a duct and 1"from port do not apply). Horizontal trapeze support system may be incor- any edge near a 90° bend, spaced on 6" centers. Pins are locked porated into the wrap enclosure. into place with 134" diameter round or square, galvanized steel, A. First Layer— Butt Joint(Figure 2) speed clips or cup head pins. Pins that extend beyond the outer The first layer of FastWrap XL is cut to completely wrap around the blanket wrap layer shall be turned down to eliminate sharp edges or perimeter of the duct with enough excess to provide a tight butt joint the excess length cut off. where the blanket ends meet. The joints of adjacent blankets are E. Grease Duct Access Door Installation (Figure 4) firmly butted against each other. This interior layer can be held tem- Four galvanized steel threaded rods, %"diameter by 4X"to 5"long porarily in place with filament tape spaced 1-1/2"from each blanket are welded to the duct at the corners of the door opening. Four 4" edge, and spaced on nominal 10-1/2" centers along the center of long steel tubes fit over the threaded rods to hold the door to the the blanket. While not required, the inside layer can be installed duct and protect the wrap from damage as the door is removed. with 3" overlaps along perimeter and adjacent blankets. Four 5" long 12 gage insulation pins are welded to the door panel B. Second Layer—3" Overlap, or 6" Collar(Figure 2) for installation of the blanket. Three layers of FastWrap XL are The second layer of FastWrap XL is cut to completely wrap around impaled over the 12 gage insulation pins on the 16 gauge door the perimeter of the first layer, with enough excess to overlap itself panel and held in place with speed clips. Each layer must have min- not less than 3". Joints in the second layer should be staggered a imum 1"overlap over the previous layer. When the door is installed, minimum of 12 inches from joints on the inner layer. Adjacent blan- this first and second layer must fit tightly against the wrap surround- kets on the second layer must overlap each other by not less than ing the door opening to form tight butt joints. Pins that extend 3". As an alternative to overlaps on adjacent blankets installed on beyond the outer layer of FastWrap XL shall be turned down to the second layer, adjacent blankets can be tightly butt jointed and avoid sharp points on the door. The steel tubes are placed over the wrapped with a 6" wide FastWrap XL collar centered over the butt threaded rods. The insulated door panel is placed over the thread- joint. This outside layer can be held temporarily in place with fila- ed rods covered by the steel tubes and held in place with washers ment tape spaced 1 X'from each blanket edge,and spaced on nom- and wing nuts. FireMaster F2-HT-XL3 Access Doors are tested and inal 10X" centers along the center of the blanket. Mechanical approved per ESR 2213 as alternatives to field fabricated doors. attachment as described in Section D must be used to make the Installations instructions for the F2-HT-XL3 door are included with installation permanent the complete assembly. F. Through-Penetration Fire Stop System (Figure 5) 9. Maintenance and Repair When-.,the duct penetrates a fire rated wall, ceiling, or floor, an No maintenance is required when installed in accordances with approved fire stop system must be employed. Thermal Ceramics installation instructions. Tremco Inc. Fyre Sil®or Fire Sil S/L If damage is limited to the foil facing,aluminum foil tape can be used Sealant to repair the foil facing. Specificed Technologies Inc. Pensil®300 If an area of blanket is found to be damaged the following procedure Rectoseal 835+TM Sealant must be incorporated. HILTI Inc. IFS One TM Sealant - If the damaged area is larger than 8"x 8"the entire wrap section must be removed and replaced according to Thermal Ceramics Prior to installing this firestop'system the surfaces of all openings and installation instructions. penetrating items needs to be clean and dry. *If the damaged area is small(less than 8"x 8"),the damaged area Cut the aluminum scrim facing off FastWrap XL blanket to expose the must be cut away and replaced with a new section 1"larger in length core blanket. FastWrap XL scrap blanket must be packed into the and width than the cut out are, such that the new section can be annular space at minimum 50% compression. The packing material compressed tightly into the cut out area. All cut edges of the new must be recessed a minimum W'from the surface of the concrete or section must be taped and sealed wth aluminum foil tape. The new gypsum wall. Install a minimum of 3C of approved firestop sealant section must be held in place with either pinning or banding per into the recessed opening. When there is no room in the remaining Thermal Ceramics installation instructions/ annular space to wrap the duct with FastWrap XL material, the 10. Limitations enclosure may terminate above and below the floor/ceiling or wall assembly as shown in figure 5 by mechanically attaching the 'Thermal Ceramics FastWrap XL shall be installed in accordance FireMaster to the termination point above and below the termination with these installation instructions. The integrity of FastWrap XL area with bands or pins. systems is limited to the quality of the installation. *For personal protective equipment recommendations see the MSDS. Thermal Ceramics is a trademark of Morgan Crucible Company plc. FireMaster and FastWrap are trademarks of Thermal Ceramics Inc. FastWrap products are manu- factured by Thermal Ceramics Inc.and are distributed by authorized distributors. Tremco and Fyre-Sil are trademarks of Tremco Inc. Thermal Ceramics Thermal Ceramics FireMaster FastWrap XL 2 Sided Wrap Detail for FireMaster FastWrap XL 3 Sided Wrap Detail for Attaching to Walls/Ceilings 1 or 2 Hour Attaching to Walls/Ceilings 1 or 2 Hour Grease or Air Duct Grease or Air Duct 3 \ 3 `_\ \ \ = 4 \\ \ \ \ 4 8 \= 8 \ 7 7 2 6 2 3 6 Figure 1 1. Concrete slab 5. Air gap (8" maximum) 2. Two layers FireMaster FastWrap XL 6. Duct 3. Concrete fastener system 7. Steel banding 1/2"wide minimum 4 1/8"thick x 2"-3" wide bar stock per- 8 Banding clip forated 12" o.c. Thermal Ceramics 1 � FireMaster FastWrap XL Commercial Kitchen Grease Duct System 1 or 2 Hour Shaft Alternative Zero Clearance to Combustible y ten° •c 1 +.v F L�}i {••''rye`69' 9 � 1 �4 2 D7, �-,"71- aa£caa l- 'sc•5lsvxasx'ha+a' , 0• '?' S' f 1 •a ,1I BUTT JONPFI OLLAR, Figure 2 1. Two layers FireMaster FastWrap XL 2. Steel banding 1/2"wide minimum 3. Tight butt joints on inner layer 4 Minimum 3" overlap on perimeter and between adjacent blanket on outside layer 5. Minimum 3/8" diameter hanger rod 6. Minimum 2" x 2" x 1/8" angle 7. 10ptimal 6" FastWrap XL collar Thermal Ceramics FireMaster FastWrap XL Typical Insulation Pin Layout For Duct Spans >24"Wide To Prevent Blanket Sag Wm W y K 1 � T� [BitlF.Y [[84 SIDE ELEVATION END ELEVATION ,ova' 'i.+.RIES BOTTOM VIEW Figure 3 1.IMinimurn 12 gauge steel insulation pins Thermal Ceramics FireMaster FastWrap XL Access Door Systems Commercial Kitchen Grease Duct 4 ? 2 1 FireMaster DuctMate 4 n FireMaster Field t, 6 F2-HT Door System Fabricated Door System Figure 4 1 DuctMate® F2-HT Access Door or 16 5. Spool pieces gauge cover plate 2. All thread rods 6. Wing nuts and washers 3. Installation pins with speed clips Outer cover plate Three layers FastWrap XL with mini- 7 labeled "ACCESS 4. mum 1" overlaps and all edges sealed DOOR-DO NOT wtih aluminum tape OBSTRUCT" Thermal Ceramics FastWrap XL Through Penetration System 1 or 2 Hour Grease Duct 2 2 4 d d S 5 SECTION A-A SECTION -A 1 i fp A A A A FLOOD VIEW FLOOR Vr E Fast'A(rap XL Fa,st%Alrap XL Termi hated At The Top And Bottom Continuous Through Sudaco Of Tho Fl000rollIng Asscinbly Tho 17Icot-10oElnn Assonibl Figure 5 1 Duct 2 Two layers FastWrap XL 3 Scrap pieces of FastWrap XL 4 Approved Through Penetration FireStop Sealant 5 IRated floor or wall North America-Sales Offices South America-Sales Offices Colombia Canada Argentina T.+57(2)2282935/2282803/2282799 T. +1(905)335 3414 T.+54(11)4373 4439 F:+54(11)4372 3331 F:+57(2)2282935/2282803/23722085 F:+1(905)335 5145 Brazil Guatemala Mexico T:+55(21)2418 1366 F:+55(21)2418 1205 T+50(2)4733 295/6 T+52(555)576 6622 Chile F:+50(2)4730 601 F:+52(555)576 3060 T.+56(2)854 1064 F:+56(2)854 1952 Venezuela United States of America T:+58(241)878 3164 Eastern T:+1.800.338.9284 F:+1.866.785.2764 F:+58(241)878 6712 Western T+1.866.785.2738 F:+1.866.785.2760 04.08/7 14-23615.OM 140 PIKE STREET - AREA#1 Fire Sprinkler Reports for Peter Marco 140 Pike Street Mattituck, New York 51 �ESSIO���° Prepared By: John Condon Condon Engineering, P.C. 1755 Sigsbee Road Mattituck, New York 631-298-1986 December 7,2021 L Y Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Condon Engineering �� I t� 140 Pike Street-Area#1 i � � Mattituck, NY 11952 7 Z. a.5 Page 2 General Project Data Report General Data Project Title: 140 Pike Street-Area#1 Project File Name: Fire Sprinkler Plan 140 Pike Street- Area#1 ..fiw Designed By: John Condon Date: December 7, 2021 Code Reference: NFPA 13 Approving Agency: LOCAL JURISDICTION Client Name: Peter Marco Phone: Address: 140 Pike Street City, State Zip Code: Mattituck, New York Home Address 140 Pike St Mattituck, New York Company Name: Condon Engineering, P.C. Representative: John J. Condon, P.E. Company Address: 1755 Sigsbee Road City And State: Mattituck, New York Phone: 631-298-1986 Building Name: 140 Pike Street Building Owner: Contact at Building: Peter Marco Phone at Building: Address Of Building: 140 Pike Street City, State Zip Code: Mattituck, New York 11952 Project Data Description Of Hazard: Ordinary 1 Sprinkler System Type: Wet Design Area Of Water Application: 1368 ftz Maximum Area Per Sprinkler: 130 ftz Default Sprinkler K-Factor: 5.60 K Default Pipe Material: SCHED 40 STEEL BLK Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 250.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: Reliable Model: F1 FR56 Size: 1/2 Temperature Rating: 165 F NONE Water Supply Test Data Source Of Information: SCWA Test Hydrant ID: 820068000 Date Of Test: 11-22-2021 Hydrant Elevation: 0 ft Static Pressure: 66.00 psi Test Flow Rate: 2026.00 gpm Test Residual Pressure: 54.00 psi Calculated System Flow Rate: 548.84 gpm Calculated Inflow Residual Pressure: 58.75 psi Available Residual Pressure At System Flow: 64.93 psi Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 7.00 psi Minimum Desired Flow Density: 0.15 gpm/ftz Maximum Water Velocity: 20.00 ft/s Maximum Frictional Loss/ 100 feet: 20.00 psi Number Of Active Nodes: 24 Number Of Active Pipes: 23 Number Of Inactive Pipes: 0 Number Of Active Sprinklers: 12 Number Of Inactive Sprinklers: 0 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#1 .fiw Tuesday, December 7, 2021, 2:06 PM I W Fire-Fire Sprinkler Hydraulics Calculation Program ? Elite Software Development,Inc.-! Condon Engineering _, tr 140 Pike Street-Area#1 Mattituck,NY 11952 f r.i"7 Page 3 Fire Sprinkler Input Data Node Input Data Area Group Sprinkler Pressure Node Elev(ft) Non-Sprinkler Node Node Description Branch Dia. KFactor(K) Estimate (psi) Branch Non- Flow(gpm) No. Branch Description (in) Branch Len. Branch Stnd Stnd Fittings Branch Sprk (ft) Fittings (ft) KFactor(K) 1 Sprinkler A 5.60 12.13 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 2 Sprinkler A 5.60 13.60 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 3 Sprinkler A 5.60 20.46 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 4 Sprinkler A 5.60 30.67 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 5 Sprinkler A 5.60 12.47 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 6 Sprinkler A 5.60 14.87 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 7 Sprinkler A 5.60 20.87 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 8 Sprinkler A 5.60 31.54 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 9 Sprinkler A 5.60 15.08 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 10 Sprinkler A 5.60 16.05 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 11 Sprinkler A 5.60 22.82 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 12 Sprinkler A 5.60 34.74 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 35 No Discharge ---- N/A 32.73 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 36 No Discharge ---- N/A 33.65 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 37 No Discharge ---- N/A 37.04 0.00 0.00 0.000 0.0 ---- 0.0 0.00 38 No Discharge ---- N/A 41.32 0.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#1 .fiw Tuesday, December 7, 2021, 2:06 PM r �,Fire°-.Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc.i Condon Engineering: 140 Pike Street-Area#1 Mattituck, NY 11952 ri.+>- Page 4', Fire Sprinkler Input Data Node Input Data (cont'd) Area Group Sprinkler Pressure Node Elev(ft) Non-Sprinkler Node Node Description Branch Dia. KFactor(K) Estimate(psi) Branch Non- Flow(gpm) No. Branch Description (in) Branch Len. Branch Stnd Stnd Fittings Branch Sprk (ft) Fittings (ft) KFactor(K) 39 No Discharge ---- N/A 39.86 6.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 60 No Discharge ---- N/A 41.18 6.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 61 No Discharge ---- N/A 46.21 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 62 No Discharge ---- N/A 46.87 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 63 No Discharge ---- N/A 43.81 3.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 64 No Discharge ---- N/A 53.39 3.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 65 No Discharge ---- N/A 57.47 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 66 No Discharge ---- N/A 58.75 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#1 .fiw Tuesday, December 7, 2021, 2:06 PM Fire-Fire Sprinkler Hydraulics Calculation Program T Elite Software Development,Inca! Condon.Engineering ; 140 Pike Street-Area#1 Mattituck, NY 11952 Page 5 Fire Sprinkler Input Data Pipe Input Data Nominal Nominal Fitting Total CFactor Beg. End. Pipe Description Diameter Type Fitting Length Length Length (gpm/inch- Node Node (inch) Group Data (feet) (feet) (feet) psi) 1 2 SCHED 40 STEEL BLK 1.000 0 E 10.50 1.40 11.90 120 2 3 SCHED 40 STEEL BLK 1.000 0 14.50 0.00 14.50 120 3 35 SCHED 40 STEEL BLK 1.000 0 T 7.00 3.50 10.50 120 4 35 SCHED 40 STEEL BLK 1.000 0 T 3.50 3.50 7.00 120 5 6 SCHED 40 STEEL BLK 1.000 0 E 17.50 1.40 18.90 120 6 7 SCHED 40 STEEL BLK 1.000 0 12.00 0.00 12.00 120 7 36 SCHED 40 STEEL BLK 1.000 0 T 7.00 3.50 10.50 120 8 36 SCHED 40 STEEL BLK 1.000 0 T 3.50 3.50 7.00 120 9 10 SCHED 40 STEEL BLK 1.000 0 E 5.00 1.40 6.40 120 10 11 SCHED 40 STEEL BLK 1.000 0 12.00 0.00 12.00 120 11 37 SCHED 40 STEEL BLK 1.000 0 T 7.00 3.50 10.50 120 12 37 SCHED 40 STEEL BLK 1.000 0 T 3.50 3.50 7.00 120 35 36 SCHED 40 STEEL BLK 2.000 0 10.50 0.00 10.50 120 36 37 SCHED 40 STEEL BLK 2.000 0 10.50 0.00 10.50 120 37 38 SCHED 40 STEEL BLK 2.000 0 E 2.50 3.50 6.00 120 38 39 SCHED 40 STEEL BLK 3.000 0 E 6.00 4.90 10.90 120 39 60 SCHED 40 STEEL BLK 3.000 0 T 2.00 10.70 12.70 120 60 61 SCHED 40 STEEL BLK 4.000 0 E 10.50 7.10 17.60 120 61 62 SCHED 40 STEEL BLK 4.000 0 2E 9.50 14.20 23.70 120 62 63 SCHED 40 STEEL BLK 4.000 0 E 7.50 7.10 14.60 120 63 64 Backflo Prev 9.500 Loss 64 65 SCHED 40 STEEL BLK 4.000 0 2E 8.00 14.20 22.20 120 65 66 SCHED 40 STEEL BLK 4.000 0 T 32.00 14.20 46.20 120 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#1 .fiw Tuesday, December 7, 2021, 2:06 PM ;Fire'=Fire Sprinkler.,Hydraulics Calculation Program :; •`Elite Software Development,Inc:j Condon Engineering ,'�. 140 Pike,Street'-Area#1. Mattituck,NY.11952` . Fire Sprinkler Output Data Overall Node Groupings Output Data Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out(+) In (-) Residual Flow At Beg. Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure (psi) Node(gpm) 1 2 0 -19.50 19.50 0.00 0.00 - 12.13 2 1 0 19.50 20.65 0.00 0.00 13.60 0.00000 2 3 0 -40.15 3 2 0 40.15 25.33 0.00 0.00 20.46 0.00000 3 35 0 -65.48 4 35 0 -31.02 31.02 0.00 0.00 30.67 0.00000 5 6 0 -19.77 19.77 0.00 0.00 12.47 0.00000 6 5 0 19.77 21.60 0.00 0.00 14.87 0.00000 6 7 0 -41.37 7 6 0 41.37 25.58 0.00 0.00 20.87 0.00000 7 36 0 -66.95 8 36 0 -31.45 31.45 0.00 0.00 31.54 0.00000 9 10 0 -21.75 21.75 0.00 0.00 15.08 0.00000 10 9 0 21.75 22.44 0.00 0.00 16.05 0.00000 10 11 0 -44.18 11 10 0 44.18 26.75 0.00 0.00 22.82 0.00000 11 37 0 -70.93 12 37 0 -33.01 33.01 0.00 0.00 34.74 0.00000 35 3 0 65.48 0.00 0.00 0.00 32.73 0.00000 35 4 0 31.02 35 36 0 -96.50 36 7 0 66.95 0.00 0.00 0.00 33.65 0.00000 36 8 0 31.45 36 35 0 96.50 36 37 0 -194.90 37 11 0 70.93 0.00 0.00 0.00 37.04 0.00000 37 12 0 33.01 37 36 0 194.90 37 38 0 -298.84 38 37 0 298.84 0.00 0.00 0.00 41.32 0.00000 38 39 0 -298.84 39 38 0 298.84 0.00 0.00 0.00 39.86 0.00000 39 60 0 -298.84 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#1 Aw Tuesday, December 7, 2021, 2:06 PM Fire Fire Sprinkler Hydraulics Calculation Program. Elite:Software Development,Inc:;# Condon.Engineering a� 140 Pike_Street,Area#1'i 'MattitUck,'NY 11952 . Page Fire Sprinkler Output Data Overall Node Groupings Output Data (cont'd) Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out(+) In (-) Residual Flow At Beg. Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure (psi) Node (gpm) 60 39 0 298.84 0.00 0.00 0.00 41.18 0.00000 60 61 0 -298.84 61 60 0 298.84 0.00 0.00 0.00 46.21 0.00000 61 62 0 -298.84 62 61 0 298.84 0.00 0.00 0.00 46.87 0.00000 62 63 0 -298.84 63 62 0 298.84 0.00 0.00 0.00 43.81 0.00000 63 64 0 -298.84 64 63 0 298.84 0.00 0.00 0.00 53.39 0.00000 64 65 0 -298.84 65 64 0 298.84 0.00 0.00 0.00 57.47 0.00000 65 66 0 -298.84 66 65 0 298.84 0.00 0.00 -298.84 58.75 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#1 Aw Tuesday, December 7, 2021, 2:06 PM Wd 90:Z '6ZOZ 'L jagweoad 'Aepsenl nnll• eaJd-1994S 94d OK veld jalNuudS aj13\...\:o £ZZ'K 09'06 0 ££'9Z OZ6 >118 1331S Ob a3HOS 000'0 09'£ 1 MOL 6VO'6 t,01£ 00'0 00'0 00'0 L£ £ZZ'K 001 99t79£'6 9L'9Z 00'6 Z8'ZZ 9L'9Z 00'0 09'9 6 6 VZ6'0 09'06 0 £Z'6 OZ6 >118 1331S Ot,Q3HDS 000'0 00'0 ----- 09'96 L907 99'E£ 00'0 00'0 00'0 9£ t,Z6'0 09'06 Z0880'0 00'0 007 £L'Z£ 00'0 00'0 00'0 9£ 90 6'Z 00'L 0 89'6 6 OZ 6 N18 1331S Otr 03HOS 000'0 09'E 1 Sty'6£ 6V0'6 99'££ 00'0 00'0 00'0 9£ 90 6'Z OS'£ t800£'0 9V 6£ 00'6 t79'6£ 9b'6£ 00'0 09'9 8 68L76 09'06 0 98't7Z OZ6 >118 1331S Ot,43HOS 000'0 OS'£ 1 96'99 6b0'6 99'£E 00'0 00'0 00'0 9£ 68L,Z6 001 LZL 6Z'6 89'92 00'6 L8'OZ 89'92 00'0 09'9 L Z90'Z 001 0 69'6 6 OU >118 1331S 0t,a3HOS 000'0 09'£ 1 ZO'6£ 6b0'6 £L'ZE 00'0 00'0 00'0 9E Z90'Z OS'£ 9 6E6Z'O ZO'6E 00'6 L9'OE ZO'6£ 00'0 09'S b 89Z'Z6 09'06 0 6E't7Z OZ6 >i18 1331S Ot,a3HOS 000'0 OS'£ 1 8t"99 6tO"6 EL'ZE 00'0 00'0 00'0 S£ 89Z'Z6 001 9E896'6 £E'9Z 00'6 9VOZ ££'SZ 00'0 09'9 E OLL'9 0076 0 0 '96 OZ6 >118 1331S Ot,43HOS 000'0 00'0 ----- 8 Vt t7 6170'6 Z8'ZZ 9L'9Z 00'0 09'9 6 6 OLL'9 0076 Kt799'0 t7t7'ZZ 00'6 90'96 tib'ZZ 00'0 09'9 06 £L6'0 Ot7'9 0 L0'8 OZ6 >118 1331S Ot,43HOS 000'0 Ot7'6 3 SL'6Z 6170'6 90'96 t7t7'ZZ 00'0 09'9 06 £L6'0 00'9 86696'0 SL'6Z 00'6 80'96 9L'6Z 00'0 09'9 6 V66'9 00'Z6 0 9£'96 OU >118 1331S OV a3HOS 000'0 00'0 ----- L£'H7 6VT 6 L8'0Z 89'92 00'0 09'9 L 1766'9 00'Z 6 £966t7'0 09'6Z 00'6 L817 09'LZ 00'0 09'9 9 60t7'Z 06'86 0 t7£'L OU >118 1331S Ot,43HOS 000'0 OV 6 3 LL'66 6b0'6 L8'b6 09'6Z 00'0 09'9 9 60t7'Z 0916 9t7LZ6'0 LL'66 00'6 LVZ6 LL'66 00'0 09'9 9 998'9 09176 0 66't76 OZ6 >118 1331S Ot,(13HOS 000'0 00'0 ----- 96'Ot7 610'6 9VOZ ££'9Z 00'0 09'9 E 998'9 09't76 ZLZLV0 S9'0Z 00'6 09'£6 99'OZ 00'0 09'9 Z 8LV 6 06'6 6 0 t7Z'L OZ 6 >118 1331S OV 43HOS 000'0 Ot7'6 3 OS'66 6b0'6 09'£6 99'0Z 00'0 09'9 Z 8Lt7'6 09'06 £ZVZ6'0 09'66 00'6 £6'Z6 09'66 00'0 09'9 6 (Isd)-id 01) dj!D-adA1 (sdt) anlen-0 (!sd) (wd6) (N) aPoN ual-tot sbulpj �ltloolan 0991)(lsd)-3d 'ela aplsul ajnssaJd a6jeyosla aotoej>{ pu3 isd - 'ual-;!3 (11/!sd) (wd6) ei wo en isa aso d UOIIen913 e o 6a ( ) 3d -uel-edld UPI '3 (wd6) b a 'WON I P. 2j HMS I P N 8 e4ea lndlnp adid Ileaanp e}lea }ndlnp jel)iuiadS a iii g.a ed AN ' on3qjeW �'#eaay-3aaa3S aM!d Ot?6 } r'r Buu69u!Bu3 uopuoo, ':;auj';uawdo�ana❑a�ennyoga;�13 weaBad"uoi;elna�e�sajneap�SH�a!�u!�dg ani ani ;Fire'=Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc.'], cordon Engineering ` Mattituck, NY 11952 _ 1 140 Pike Street''Area#J1 Page 9; Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) /ft Pipe-Len L q (gpm) F. . . Beg. Nodal Spk/Hose Residual Nom. Dia. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 12 5.60 0.00 33.01 34.74 1.00 33.01 . 0.32894 3.50 2.303 37 0.00 0.00 0.00 37.04 1.049 33.01 T 3.50 0.000 SCHED 40 STEEL BLK 120 12.25 0 7.00 2.303 36 0.00 0.00 0.00 33.65 2.00 0.00 0.32316 10.50 3.393 37 0.00 0.00 0.00 37.04 2.067 194.90 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 18.63 0 10.50 3.393 37 0.00 0.00 0.00 37.04 2.00 0.00 0.71262 2.50 4.276 38 0.00 0.00 0.00 41.32 2.067 298.84 E 3.50 0.000 SCHED 40 STEEL BLK 120 28.57 0 6.00 4.276 38 0.00 0.00 0.00 41.32 3.00 0.00 0.10413 6.00 1.135 39 0.00 6.00 0.00 39.86 3.068 298.84 E 4.90 -2.598 SCHED 40 STEEL BLK 120 12.97 0 10.90 -1.463 39 0.00 6.00 0.00 39.86 3.00 0.00 0.10413 2.00 1.322 60 0.00 6.00 0.00 41.18 3.068 298.84 T 10.70 0.000 SCHED 40 STEEL BLK 120 12.97 0 12.70 1.322 60 0.00 6.00 0.00 41.18 4.00 0.00 0.02772 10.50 0.488 61 0.00 -4.50 0.00 46.21 4.026 298.84 E 7.10 4.547 SCHED 40 STEEL BLK 120 7.53 0 17.60 5.034 61 0.00 -4.50 0.00 46.21 4.00 0.00 0.02772 9.50 0.657 62 0.00 -4.50 0.00 46.87 4.026 298.84 2E 14.20 0.000 SCHED 40 STEEL BLK 120 7.53 0 23.70 0.657 62 0.00 -4.50 0.00 46.87 4.00 0.00 0.02772 7.50 0.405 63 0.00 3.50 0.00 43.81 4.026 298.84 E 7.10 -3.464 SCHED 40 STEEL BLK 120 7.53 0 14.60 -3.059 63 Backflo 3.50 43.81 298.84 Prev 64 9.50 psi 3.50 53.39 64 0.00 3.50 0.00 53.39 4.00 0.00 0.02772 8.00 0.615 65 0.00 -4.50 0.00 57.47 4.026 298.84 2E 14.20 3.464 SCHED 40 STEEL BLK 120 7.53 0 22.20 4.079 65 0.00 -4.50 0.00 57.47 4.00 0.00 0.02772 32.00 1.281 66 0.00 -4.50 0.00 58.75 4.026 298.84 T 14.20 0.000 SCHED 40 STEEL BLK 120 7.53 0 46.20 1.281 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#1 .fiw Tuesday, December 7, 2021, 2:06 PM Fire'=Fire.Sprinkler Hydraulics Calculation Program,' EliteZoftware Developi66ht,.11146:1 Condon Engineering ' � 140 Pike Street-Area#1 Mattituck,NY 91952 Pae 10} Fire Sprinkler Output Data Overall Sprinkler Output Data Flowing Area Group Sprinkler Sprinkler Residual Flowing Area Flowing Sprinkler Sprinkler Elevation Pressure 2 Density Discharge Node No. Code KFactor(K) (feet) (psi) (ft ) (gpm/ft2) (gpm) 1 A 5.60 0.00 12.13 130.00 0.150 19.50 2 A 5.60 0.00 13.60 130.00 0.159 20.65 3 A 5.60 0.00 20.46 130.00 0.195 25.33 4 A 5.60 0.00 30.67 130.00 0.239 31.02 5 A 5.60 0.00 12.47 130.00 0.152 19.77 6 A 5.60 0.00 14.87 130.00 0.166 21.60 7 A 5.60 0.00 20.87 130.00 0.197 25.58 8 A 5.60 0.00 31.54 130.00 0.242 31.45 9 A 5.60 0.00 15.08 130.00 0.167 21.75 10 A 5.60 0.00 16.05 130.00 0.173 22.44 11 A 5.60 0.00 22.82 130.00 0.206 26.75 12 A 5.60 0.00 34.74 130.00 0.254 33.01 Sub Totals For Group A 1560.00 0.192 298.84 Totals For All Groups 1560.00 0.192 298.84 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#1 .fiw Tuesday, December 7, 2021, 2:06 PM Fire re Sprinkler Hydraulics Calculation Program Elite:Software"Devolopirient,Ind" Coridon Erigineering - 140 Pike Street-•Area#.1; Mattituck,,NY 11952 Page 111 Fire Sprinkler Output Summa Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number: 1 HMD Actual Residual Pressure: 12.13 psi HMD Actual GPM: 19.50 gpm Sprinkler Summary Sprinkler System Type: Wet Specified Area Of Application: 1368.00 ft2 Minimum Desired Density: 0.150 gpm/ft2 Application Average Density: 0.218 gpm/ft2 Application Average Area Per Sprinkler: 114.00 ft2 Sprinkler Flow: 298.84 gpm Average Sprinkler Flow: 24.90 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity( In Pipe 37-38) 28.57 ft/sec Maximum Velocity Pressure( In Pipe 37-38) 5.49 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0000 psi Actual Average Nodal Pressure Imbalance: 0.0000 psi Actual Maximum Nodal Flow Imbalance: 0.0000 gpm Actual Average Nodal Flow Imbalance: 0.0000 gpm Overall Network Summary Number Of Unique Pipe Sections: 23 Number Of Flowing Sprinklers: 12 Pipe System Water Volume: 56.43 gal Sprinkler Flow: 298.84 gpm Non-Sprinkler Flow: 0.00 gpm Demand Flow Excluding Exterior Hose Flow: 298.84 gpm Exterior Hose Flow: 250.00 gpm Minimum Required Residual Pressure At System Inflow 58.75 psi Node: Demand Flow At System Inflow Node: 548.84 gpm C:\...\Fire Sprinkler Plan 140 Pike Street-Area#1 .fiw Tuesday, December 7, 2021, 2:06 PM Fire F..ire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc Condon'Engineering x 140 Pike Street=Area#1 .Mattitkk„NY 11952. i Pa e,1,2' Fire Sprinkler Output Data 'Hydraulic Supply/Demand Graph 100 90 80 .N 70 66 !1. 60 � 54 fU) 50 N 40 11 1 30 20 10 0 3 6 9 12 15 18 21 24 27 30 Flowrate(MO) gpm Supply Curve Data Static Pressure: 66 psi Test Residual Pressure: 54 psi Test Flow Rate: 2026 gpm Demand Curve Data Calculated Residual Pressure: 58.75 psi Calculated Flow Rate: 548.84 gpm Exterior Hose Flow: 250.00 gpm Excess Available Residual Pressure At Calculated Flow: 6.18 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 11.45 psi C:\...\Fire Sprinkler Plan 140 Pike Street-Area#1 .fiw Tuesday, December 7, 2021, 2:06 PM condoneng@optonline.net From: Sean Baccei <sean@jpastudio.com> Sent: Wednesday, December 1, 2021 2:26 PM To: condoneng@optonline.net; liberty631 @optonline.net Subject: 18 Bay View Road Happy holidays to you both.... John C.-we've chosen the contractor for this residential project which you did the engineering. It will be Adam Christopherson who will have John at Liberty Iron Works do to the steel. Apparently you two know each other well? Always a small world, probably more so out there.... Anyhow-the steel numbers are coming in quite high,comparatively, and we are wondering if there is any room to dial back either some of the steel itself,or at least some of the thicknesses of the members. For instance,there is a 6,000$ savings to go to 4"x 4"x 1/4" columns in lieu of the 5x5x1/2 currently detailed. Obviously,we do not want to compromise the structure. But I am doing my due diligence on trying to determine any way to shave some dollars off the overall cost. Without digging in and generating any fee(for now)also interested in any way to remove some steel for more traditional framing, even if it means tie-backs or considerably more framing members. The project is permitted at this point,and we'd only make a change if we feel it doesn't impact both the design aesthetic or the structure. If this means fee for running noew numbers(and new drawings)we can discuss further, maybe without Liberty on the line. Happy to make this a call, if that would expedite things,or allow some spitbaling of ideas. Just let me know. Best regards, Sean Sean Baccei Project Manager JPA Studio i rf 140 PIKE STREET - AREA#2 Fire Sprinkler Reports for Peter Marco 140 Pike Street Mattituck, New York 1684 SS80���' Prepared By: John Condon Condon Engineering,P.C. 1755 Sigsbee Road Mattituck, New York 631-298-1986 February 25,2022 Fire=Fire Sprinkler Hydraulics Calculation Program ,f Elite Software Development,lnc.„ Condon Engineering ' 140 Pike Street-Area#2.� Mattituck,NY 11952 Pade 2"? General Pro'ect Data Report General Data Project Title: 140 Pike Street-Area#2 Project File Name: Fire Sprinkler Plan 140 Pike Street- Area#2 Rev2..fiw Designed By: John Condon Date: February 25, 2022 Code Reference: NFPA 13 Approving Agency: LOCAL JURISDICTION Client Name: Peter Marco Phone: Address: 140 Pike Street City, State Zip Code: Mattituck, New York Home Address 140 Pike St Mattituck, New York Company Name: Condon Engineering, P.C. Representative: John J. Condon, P.E. Company Address: 1755 Sigsbee Road City And State: Mattituck, New York Phone: 631-298-1986 Building Name: 140 Pike Street Building Owner: Contact at Building: Peter Marco Phone at Building: Address Of Building: 140 Pike Street City, State Zip Code: Mattituck, New York 11952 Project Data Description Of Hazard: Light Hazard Sprinkler System Type: Wet Design Area Of Water Application: 1071 ft2 Maximum Area Per Sprinkler: 225 ft2 Default Sprinkler K-Factor: 5.60 K Default Pipe Material: SCHED 40 STEEL BLK Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 250.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: Reliable Model: G5 Size: 1/2 Temperature Rating: 165 F NONE Water Supply Test Data Source Of Information: SCWA Test Hydrant ID: 820068000 Date Of Test: 11-22-2021 Hydrant Elevation: 0 ft Static Pressure: 66.00 psi Test Flow Rate: 2026.00 gpm Test Residual Pressure: 54.00 psi Calculated System Flow Rate: 518.11 gpm Calculated Inflow Residual Pressure: 40.50 psi Available Residual Pressure At 65.04 psi System Flow: Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 7.00 psi Minimum Desired Flow Density: 0.10 gpm/ft2 Maximum Water Velocity: 20.00 ft/s Maximum Frictional Loss/ 100 feet: 20.00 psi Number Of Active Nodes: 29 Number Of Active Pipes: 28 Number Of Inactive Pipes: 0 Number Of Active Sprinklers: 11 Number Of Inactive Sprinklers: 0 C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM Fire='Fire Sprinkler Hydraulics Calculation ProgramElrte Software Development,,Inca( Condon Engineering. 140 Pike Street-Area#2'i Mattituck,..NY.11952 7Page, Fire Sprinkler Input Data I.Node Input Data. Area Group Sprinkler Pressure Node Elev(ft) Non-Sprinkler Node Node Description Branch Dia. KFactor(K) Estimate(psi) Branch Non- Flow(gpm) No. Branch Description (in) Branch Len. Branch Stnd Stnd Fittings Branch Sprk (ft) Fittings (ft) KFactor(K) 12 Sprinkler A 5.60 19.05 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 13 Sprinkler A 5.60 19.04 8.00 0.00 0.000 0.0 ---- 0.0 0.00 14 Sprinkler A 5.60 19.31 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 15 Sprinkler A 5.60 18.90 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 16 Sprinkler A 5.60 16.14 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 17 Sprinkler A 5.60 16.60 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 18 No Discharge ---- N/A 17.43 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 19 Sprinkler A 5.60 18.70 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 20 No Discharge ---- N/A 20.09 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 21 Sprinkler A 5.60 20.35 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 22 Sprinkler A 5.60 18.91 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 23 No Discharge ---- N/A 20.69 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 24 Sprinkler ---- 5.60 20.76 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 25 Sprinkler A 5.60 20.92 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 50 No Discharge ---- N/A 20.84 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 51 No Discharge ---- N/A 20.91 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM Firere Sprinkler Hydraulics,Calculation Program . 7 Elite Software Development,Inc.,? `Co'' ridor Engineering " k. 140 Pike Street-`Area#2,i Ma#tituck;NY 11952 ti_ Pa a 4`I Fire Sprinkler Input Data ,Node Input Data (cont'd) Area Group Sprinkler Pressure Node Elev(ft) Non-Sprinkler Node Node Description Branch Dia. KFactor(K) Estimate(psi) Branch Non- Flow(gpm) No. Branch Description (in) Branch Len. Branch Stnd Stnd Fittings Branch Sprk (ft) Fittings (ft) KFactor(K) 52 No Discharge ---- N/A 20.92 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 53 No Discharge --- N/A 21.22 8.00 0.00 --- 0.000 0.0 ---- 0.0 0.00 54 No Discharge ---- N/A 21.98 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 55 No Discharge ---- N/A 22.20 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 56 No Discharge ---- N/A 22.60 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 58 No Discharge ---- N/A 22.77 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 59 No Discharge ---- N/A 23.03 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 61 No Discharge ---- N/A 28.88 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 62 No Discharge ---- N/A 29.26 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 63 No Discharge ---- N/A 26.13 3.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 64 No Discharge ---- N/A 35.64 3.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 65 No Discharge ---- N/A 39.45 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 66 No Discharge ---- N/A 40.50 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM Fire,,Fire Sprinkler Hydraulics Calculation Program . Elite Sottware'Development,:adc_.:? Condon-Engineering „ ', 4*_ 140,Pike Street-.Area#2 5�=�k �'.M6tfituckj"`NY 1-1952age 5 Fire Sprinkler Input Data Pipe Input Data Nominal Nominal Fitting Total CFactor Beg. End. Pipe Description Diameter Type Fitting Length Length Length (gpm/inch- Node Node (inch) Group Data (feet) (feet) (feet) psi) 12 50 SCHED 40 STEEL BLK 1.000 0 T 6.00 3.50 9.50 120 13 52 SCHED 40 STEEL BLK 1.000 0 T 6.50 3.50 10.00 120 14 53 SCHED 40 STEEL BLK 1.000 0 T 6.50 3.50 10.00 120 15 54 SCHED 40 STEEL BLK 1.000 0 ET 11.50 4.90 16.40 120 16 18 SCHED 40 STEEL BLK 1.000 0 8.00 0.00 8.00 120 17 18 SCHED 40 STEEL BLK 1.000 0 T 1.50 3,50 5.00 120 18 20 SCHED 40 STEEL BLK 1.000 0 4.50 0.00 4.50 120 19 20 SCHED 40 STEEL BLK 1.000 0 T 4.00 3.50 7.50 120 20 21 SCHED 40 STEEL BLK 2.000 0 L 3.50 2.10 5.60 120 21 23 SCHED 40 STEEL BLK 2.000 0 4.00 0.00 4.00 120 22 23 SCHED 40 STEEL BLK 1.000 0 T 6.00 3.50 9.50 120 23 55 SCHED 40 STEEL BLK 2.000 0 T 4.50 7.10 11.60 120 24 56 SCHED 40 STEEL BLK 1.000 0 T 5.50 3.50 9.00 120 25 58 SCHED 40 STEEL BLK 1.000 0 T 5.50 3.50 9.00 120 50 51 SCHED 40 STEEL BLK 2.000 0 10.00 0.00 10.00 120 51 52 SCHED 40 STEEL BLK 2.000 0 2.00 0.00 2.00 120 52 53 SCHED 40 STEEL BLK 2.000 0 12.00 0.00 12.00 120 53 54 SCHED 40 STEEL BLK 2.000 0 T 7.00 7.10 14.10 120 54 55 SCHED 40 STEEL BLK 2.000 0 2.50 0.00 2.50 120 55 56 SCHED 40 STEEL BLK 2.000 0 1.00 0.00 1.00 120 56 58 SCHED 40 STEEL BLK 4.000 0 9.50 0.00 9.50 120 58 59 SCHED 40 STEEL BLK 4.000 0 E 4.00 7.10 11.10 120 59 61 SCHED 40 STEEL BLK 4.000 0 E 12.50 7.10 19.60 120 61 62 SCHED 40 STEEL BLK 4.000 0 E 9.50 7.10 16.60 120 62 63 SCHED 40 STEEL BLK 4.000 0 E 7.50 7.10 14.60 120 C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM Fire ire Sprinkler Hydraulics'-Calculation Program Elite Sofiware-Development,'.Inc,# Condon Engineering 140"Pike Street-Area#2;' Mattituck, NY :11952 Fire Sprinkler Input Data Pipe Input Data (cont'd) Nominal Nominal Fitting Total CFactor Beg. End. pipe Description Diameter Type Fitting Length Length Length (gpm/inch- Node Node (inch) Group Data (feet) (feet) (feet) psi) 63 64 Backflo Prev 9.500 Loss 64 65 SCHED 40 STEEL BLK 4.000 0 E 8.00 7.10 15.10 120 65 66 SCHED 40 STEEL BLK 4.000 0 T 32.00 14.20 46.20 120 C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM Fire=Fire Sprinkler Hydraulics Calculation Program Elite Software Development,'Inc:;; Condon Engineering 140 Pike Street-Area#2, Mattituck,NY 11952 Pag6 7. Fire Sprinkler Output Data Overall Node Groupings Output Data Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out(+) In (-) Residual Flow At Beg. Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure(psi) Node(gpm) 12 50 0 -24.44 24.44 0.00 0.00 19.05 13 52 0 -24.43 24.43 0.00 0.00 19.04 0.00009 14 53 0 -24.61 24.61 0.00 0.00 19.31 0.00009 15 54 0 -24.35 24.35 0.00 0.00 18.90 0.00008 16 18 0 -22.44 22.50 0.00 0.00 16.14 0.06100 17 18 0 -22.82 22.82 0.00 0.00 16.60 0.00007 18 16 0 22.44 0.00 0.00 0.00 17.43 -0.00007 18 17 0 22.82 18 20 0 -45.26 19 20 0 -24.21 24.21 0.00 0.00 18.70 0.00009 20 18 0 45.26 0.00 0.00 0.00 20.09 0.00000 20 19 0 24.21 20 21 0 -69.47 21 20 0 69.47 25.26 0.00 0.00 20.35 0.00014 21 23 0 -94.73 22 23 0 -24.35 24.35 0.00 0.00 18.91 0.00009 23 21 0 94.73 0.00 0.00 0.00 20.69 0.00000 23 22 0 24.35 23 55 0 -119.09 24 56 0 -25.51 25.51 0.00 0.00 20.76 0.00012 25 58 0 -25.61 25.61 0.00 0.00 20.92 0.00013 50 12 0 24.44 0.00 0.00 0.00 20.84 0.00000 50 51 0 -24.44 51 50 0 24.44 0.00 0.00 0.00 20.91 0.00000 51 52 0 -24.44 52 13 0 24.43 0.00 0.00 0.00 20.92 0.00000 52 51 0 24.44 52 53 0 -48.94 53 14 0 24.61 0.00 0.00 0.00 21.22 0.00000 53 52 0 48.94 53 54 0 -73.55 54 15 0 24.35 0.00 0.00 0.00 21.98 0.00000 CA...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM Fire=Fire Sprinkler Hydraulics Calculation Program 4� Elite Software Development,Inc `Condon Engineering.-. ' x 140 Pike Street Area#2 4 Mattituck,'NY 11952 . Pa e•i3 Fire Sprinkler Output Data :Overall Node Groupings Output Data (cont'd) Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out(+) In (-) Residual Flow At Beg. Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure(psi) Node (gpm) 54 53 0 73.55 54 55 0 -97.89 55 23 0 119.09 0.00 0.00 0.00 22.20 0.00000 55 54 0 97.89 55 56 0 -216.98 56 24 0 25.51 0.00 0.00 0.00 22.60 0.00000 56 55 0 216.98 56 58 0 -242.49 58 25 0 25.61 0.00 0.00 0.00 22.77 0.00000 58 56 0 242.49 58 59 0 -268.11 59 58 0 268.11 0.00 0.00 0.00 23.03 0.00000 59 61 0 -268.11 61 59 0 268.11 0.00 0.00 0.00 28.88 0.00000 61 62 0 -268.11 62 61 0 268.11 0.00 0.00 0.00 29.26 0.00000 62 63 0 -268.11 63 62 0 268.11 0.00 0.00 0.00 26.13 -0.08858 63 64 0 -268.20 64 63 0 268.20 0.00 0.00 0.00 35.64 0.08858 64 65 0 -268.11 65 64 0 268.11 0.00 0.00 0.00 39.45 0.00000 65 66 0 -268.11 66 65 0 268.11 0.00 0.00 -268.11 40.50 C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM Fire-Fire Sprinkler Hydraulics Calculation Program � Elite Software Development,Inc.i Condon Engineering �' 140 Pike Street-Area#2 Mattituck,NY 11952 7;:,,,..C Pa e 9 Fire Sprinkler Output Data Overall Pipe Output Data Beg. Nodal Spk/Hose Residual Nom. q (gpm) F. L./ft Pipe-Len.Dia. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 16 5.60 8.00 22.50 16.14 1.00 22.50 0.16107 8.00 1.289 18 0.00 8.00 0.00 17.43 1.049 22.44 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 8.33 0 8.00 1.289 17 5.60 8.00 22.82 16.60 1.00 22.82 0.16613 1.50 0.831 18 0.00 8.00 0.00 17.43 1.049 22.82 T 3.50 0.000 SCHED 40 STEEL BLK 120 8.47 0 5.00 0.831 18 0.00 8.00 0.00 17.43 1.00 0.00 0.58980 4.50 2.654 20 0.00 8.00 0.00 20.09 1.049 45.26 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 16.80 0 4.50 2.654 19 5.60 8.00 24.21 18.70 1.00 24.21 0.18542 4.00 1.391 20 0.00 8.00 0.00 20.09 1.049 24.21 T 3.50 0.000 SCHED 40 STEEL BLK 120 8.99 0 7.50 1.391 20 0.00 8.00 0.00 20.09 2.00 0.00 0.04792 3.50 0.268 21 5.60 8.00 25.26 20.35 2.067 69.47 L 2.10 0.000 SCHED 40 STEEL BLK 120 6.64 0 5.60 0.268 21 5.60 8.00 25.26 20.35 2.00 25.26 0.08507 4.00 0.340 23 0.00 8.00 0.00 20.69 2.067 94.73 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 9.06 0 4.00 0.340 22 5.60 8.00 24.35 18.91 1.00 24.35 0.18743 6.00 1.781 23 0.00 8.00 0.00 20.69 1.049 24.35 T 3.50 0.000 SCHED 40 STEEL BLK 120 9.04 0 9.50 1.781 12 5.60 8.00 24.44 19.05 1.00 24.44 0.18866 6.00 1.792 50 0.00 8.00 0.00 20.84 1.049 24.44 T 3.50 0.000 SCHED 40 STEEL BLK 120 9.07 0 9.50 1.792 50 0.00 8.00 0.00 20.84 2.00 0.00 0.00694 10.00 0.069 51 0.00 8.00 0.00 20.91 2.067 24.44 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 2.34 0 10.00 0.069 13 5.60 8.00 24.43 19.04 1.00 24.43 0.18857 6.50 1.886 52 0.00 8.00 0.00 20.92 1.049 24.43 T 3.50 0.000 SCHED 40 STEEL BLK 120 9.07 0 10.00 1.886 51 0.00 8.00 0.00 20.91 2.00 0.00 0.00694 2.00 0.014 52 0.00 8.00 0.00 20.92 2.067 24.44 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 2.34 0 2.00 0.014 14 5.60 8.00 24.61 19.31 1.00 24.61 0.19109 6.50 1.911 53 0.00 8.00 0.00 21.22 1.049 24.61 T 3.50 0.000 SCHED 40 STEEL BLK 120 9.14 0 10.00 1.911 C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM Fire=Fire Sprinkler Hydraulics Calculation Program r - i Elite Software Development,Inc:;; C6hdoriEngineering f, x 140 Pike"Street-Area#2 Mattituck, NY 11952 r„ , r Pa a 10' Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) /ft Pipe-Len L Beg. Nodal Spk/Hose Residual Nom . .. Dia. q (gpm) F. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 52 0.00 8.00 0.00 20.92 2.00 0.00 0.02506 12.00 0.301 53 0.00 8.00 0.00 21.22 2.067 48.94 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 4.68 0 12.00 0.301 15 5.60 8.00 24,35 18.90 1.00 24.35 0.18733 11.50 3.072 54 0.00 8.00 0.00 21.98 1.049 24.35 ET 4.90 0.000 SCHED 40 STEEL BLK 120 9.04 0 16.40 3.072 53 0.00 8.00 0.00 21.22 2.00 0.00 0.05325 7.00 0.751 54 0.00 8.00 0.00 21.98 2.067 73.55 T 7.10 0.000 SCHED 40 STEEL BLK 120 7.03 0 14.10 0.751 23 0.00 8.00 0.00 20.69 2.00 0.00 0.12989 4.50 1.507 55 0.00 8.00 0.00 22.20 2.067 119.09 T 7.10 0.000 SCHED 40 STEEL BLK 120 11.39 0 11.60 1.507 54 0.00 8.00 0.00 21.98 2.00 0.00 0.09039 2.50 0.226 55 0.00 8.00 0.00 22.20 2.067 97.89 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 9.36 0 2.50 0.226 24 5.60 8.00 25.51 20.76 1.00 25.51 0.20426 5.50 1.838 56 0.00 8.00 0.00 22.60 1.049 25.51 T 3.50 0.000 SCHED 40 STEEL BLK 120 9.47 0 9.00 1.838 55 0.00 8.00 0.00 22.20 2.00 0.00 0.39414 1.00 0.394 56 0.00 8.00 0.00 22.60 2.067 216.98 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 20.75 0 1.00 0.394 25 5.60 8.00 25.61 20.92 1.00 25.61 0.20577 5.50 1.852 58 0.00 8.00 0.00 22.77 1.049 25.61 T 3.50 0.000 SCHED 40 STEEL BLK 120 9.51 0 9.00 1.852 56 0.00 8.00 0.00 22.60 4.00 0.00 0.01883 9.50 0.179 58 0.00 8.00 0.00 22.77 4.026 242.49 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 6.11 0 9.50 0.179 58 0.00 8.00 0.00 22.77 4.00 0.00 0.02268 4.00 0.252 59 0.00 8.00 0.00 23.03 4.026 268.11 E 7.10 0.000 SCHED 40 STEEL BLK 120 6.76 0 11.10 0.252 59 0.00 8.00 0.00 23.03 4.00 0.00 0.02268 12.50 0.445 61 0.00 -4.50 0.00 28.88 4,026 268.11 E 7.10 5.413 SCHED 40 STEEL BLK 120 6.76 0 19.60 5.857 61 0.00 -4.50 0.00 28.88 4.00 0.00 0.02268 9.50 0.376 62 0.00 -4.50 0.00 29.26 4.026 268.11 E 7.10 0.000 SCHED 40 STEEL BLK 120 6.76 0 16.60 0.376 C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 11:22 PM Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc..i Condon•Engineering, .,r 140 Pike Street-`Area#2,j Mattituck,,NY 11952 Pae 11 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe-Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 62 0.00 -4.50 0.00 29.26 4.00 0.00 0.02268 7.50 0.331 63 0.00 3.50 0.00 26.13 4.026 268.11 E 7.10 -3.464 SCHED 40 STEEL BLK 120 6.76 0 14.60 -3.133 63 Backflo 3.50 26.13 268.20 Prev 64 9.50 psi 3.50 35.64 64 0.00 3.50 0.00 35.64 4.00 0.00 0.02268 8.00 0.342 65 0.00 -4.50 0.00 39.45 4.026 268.11 E 7.10 3.464 SCHED 40 STEEL BLK 120 6.76 0 15.10 3.806 65 0.00 -4.50 0.00 39.45 4.00 0.00 0.02268 32.00 1.048 66 0.00 -4.50 0.00 40.50 4.026 268.11 T 14.20 0.000 SCHED 40 STEEL BLK 120 6.76 0 46.20 1.048 C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc.4 Condon Engineering 1,40 Pike Street-Area#21 Mattituck,NY 11952 7fr, .s Pae 12 Fire Sprinkler Output Data Overall Sprinkler Output Data Flowing Area Group Sprinkler Sprinkler Residual Flowing Area Flowing Sprinkler Sprinkler Elevation Pressure Density Discharge Node No. Code KFactor(K) (feet) (psi) (ftz) (gpm/ft2) (gpm) 12 A 5.60 8.00 19.05 225.00 0.109 24.44 13 A 5.60 8.00 19.04 225.00 0.109 24.43 14 A 5.60 8.00 19.31 225.00 0.109 24.61 15 A 5.60 8.00 18.90 225.00 0.108 24.35 16 A 5.60 8.00 16.14 225.00 0.100 22.50 17 A 5.60 8.00 16.60 225.00 0.101 22.82 19 A 5.60 8.00 18.70 225.00 0.108 24.21 21 A 5.60 8.00 20.35 225.00 0.112 25.26 22 A 5.60 8.00 18.91 225.00 0.108 24.35 25 A 5.60 8.00 20.92 225.00 0.114 25.61 Sub Totals For Group A 2250.00 0.108 242.60 24 5.60 8.00 20.76 225.00 0.113 25.51 Sub Totals For Non-Group 225.00 0.113 25.51 Totals For All Groups 2475.00 0.108 268.11 C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM .I [ re .Fire-Sprinkler.Hydraulics Calculation Program Elite-Software`Development,'Inc Crondon Engineering ?` k 140 Pike Street=Qrea#2 Mattituck,,NY..11,952 4. Pa a 13 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number: 16 HMD Actual Residual Pressure: 16.14 psi HMD Actual Flow: 22.50 gpm Sprinkler Summary Sprinkler System Type: Wet Specified Area Of Application: 1071.00 ft2 Minimum Desired Density: 0.100 gpm/ft2 Application Average Density: 0.250 gpm/ft' Application Average Area Per Sprinkler: 97.36 ft2 Sprinkler Flow: 268.11 gpm Average Sprinkler Flow: 24.37 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity( In Pipe 55-56) 20.75 ft/sec Maximum Velocity Pressure( In Pipe 55-56) 2.90 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0057 psi Actual Average Nodal Pressure Imbalance: 0.0006 psi Actual Maximum Nodal Flow Imbalance: -0.0886 gpm Actual Average Nodal Flow Imbalance: 0.0082 gpm Overall Network Summary Number Of Unique Pipe Sections: 28 Number Of Flowing Sprinklers: 11 Pipe System Water Volume: 65.94 gal Sprinkler Flow: 268.11 gpm Non-Sprinkler Flow: 0.00 gpm Demand Flow Excluding Exterior Hose Flow: 268.11 gpm Exterior Hose Flow: 250.00 gpm Minimum Required Residual Pressure At System Inflow 40.50 psi Node: Demand Flow At System Inflow Node: 518.11 gpm C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM .r Fire=Fire Sprinkler Hydraulics Calculation Program n Elite Software Development,lnc. Condon,Engineering . tr 140 Pike Street'-Area#21� .Mattituck,,NY •11952 Pa a:14'3 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph 100 90 80 70 66 Q 60 N 54 3 U) 50 0) L ,� a 40 30 20 10 0 3 6 9 12 15 18 21 24 27 30 Flowrate(x100) gpm Supply Curve Data Static Pressure: 66 psi Test Residual Pressure: 54 psi Test Flow Rate: 2026 gpm Demand Curve Data Calculated Residual Pressure: 40.50 psi Calculated Flow Rate: 518.11 gpm Exterior Hose Flow: 250.00 gpm Excess Available Residual Pressure At Calculated Flow: 24.54 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 14.91 psi C:\...\Fire Sprinkl ... #2 Rev2.fiw Wednesday, March 9, 2022, 1:22 PM 140 PIKE STREET - AREA#3 Fire Sprinkler Reports for Peter Marco 140 Pike Street Mattituck, New York ar,, �® 1684 Prepared By: John Condon Condon Engineering,P.C. 1755 Sigsbee Road Mattituck,New York 631-298-1986 November 30,2021 t "Fire,Sprinkler Hydraulics.Calculation Program EIK6e Software Development,'lnc;.' Condon Engineering k: 140 Pike Street,,Area#3` Mattituck;._NY .1'.1952 Pa e General Project Data Report General Data Project Title: 140 Pike Street-Area#3 Project File Name: Fire Sprinkler Plan 140 Pike Street- Area#3..fiw Designed By: John Condon Date: November 30, 2021 Code Reference: NFPA 13 Approving Agency: LOCAL JURISDICTION Client Name: Peter Marco Phone: Address: 140 Pike Street City, State Zip Code: Mattituck, New York Home Address 140 Pike St Mattituck, New York Company Name: Condon Engineering, P.C. Representative: John J. Condon, P.E. Company Address: 1755 Sigsbee Road City And State: Mattituck, New York Phone: 631-298-1986 Building Name: 140 Pike Street Building Owner: Contact at Building: Peter Marco Phone at Building: Address Of Building: 140 Pike Street City, State Zip Code: Mattituck, New York 11952 Project Data Description Of Hazard: Ordinary 1 Sprinkler System Type: Wet Design Area Of Water Application: 317 ft2 Maximum Area Per Sprinkler: 130 ft2 Default Sprinkler K-Factor: 5.60 K Default Pipe Material: SCHED 40 STEEL BLK Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 250.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: Reliable Model: G5 Size: 1/2 Temperature Rating: 165 F NONE Water Supply Test Data Source Of Information: SCWA Test Hydrant ID: 820068000 Date Of Test: 11-22-2021 Hydrant Elevation: 0 ft Static Pressure: 66.00 psi Test Flow Rate: 2026.00 gpm Test Residual Pressure: 54.00 psi Calculated System Flow Rate: 329.56 gpm Calculated Inflow Residual Pressure: 32.32 psi Available Residual Pressure At 65.58 psi System Flow: Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 7.00 psi Minimum Desired Flow Density: 0.15 gpm/ft2 Maximum Water Velocity: 20.00 ft/s Maximum Frictional Loss/ 100 feet: 20.00 psi Number Of Active Nodes: 19 Number Of Active Pipes: 18 Number Of Inactive Pipes: 0 Number Of Active Sprinklers: 4 Number Of Inactive Sprinklers: 0 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Tuesday, December 7, 2021, 2:24 PM Fire',Fire Sprinkler Hydraulics.Calculation Program ; "" Elite Software Development,Inc::; 1 rte' Condon,Engineering 140 Pike Street-Area#3! 11`-:Mattituck, NY 11952 .,Pag6 31 Fire Sprinkler Input Data Node Input Data Area Group Sprinkler Pressure Node Elev(ft) Non-Sprinkler Node Node Description Branch Dia. KFactor(K) Estimate (psi) Branch Non- Flow(gpm) No. Branch Description (in) Branch Len. Branch Stnd Stnd Fittings Branch Sprk (ft) Fittings (ft) KFactor(K) 26 Sprinkler A 5.60 12.25 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 27 Sprinkler A 5.60 13.12 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 28 Sprinkler A 5.60 12.13 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 29 Sprinkler A 5.60 12.99 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 50 No Discharge ---- N/A 17.39 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 51 No Discharge ---- N/A 17.56 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 52 No Discharge ---- N/A 17.68 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 53 No Discharge ---- N/A 18.42 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 54 No Discharge ---- N/A 19.29 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 55 No Discharge ---- N/A 19.44 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 56 No Discharge ---- N/A 19.50 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 58 No Discharge ---- N/A 19.53 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 59 No Discharge ---- N/A 19.55 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 61 No Discharge ---- N/A 25.01 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 62 No Discharge ---- N/A 25.05 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 63 No Discharge ---- N/A 21.62 3.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Sunday, December 5, 2021, 3:34 PM Tire-Fire Sprinkler Hydraulics Calculation Program Elite Software"Development,Inc..' [Condon,Engin.'eering 140 Pike Street.-Area#3. Mattituck, NY 11952 _ Page 4.1 Fire Sprinkler Input Data Node_Input Data (cont'd) Area Group Sprinkler Pressure Node Elev(ft) Non-Sprinkler Node Node Description Branch Dia. KFactor(K) Estimate(psi) Branch Non- Flow(gpm) No. Branch Description (in) Branch Len. Branch Stnd Stnd Fittings Branch Sprk (ft) Fittings (ft) KFactor(K) 64 No Discharge ---- N/A 28.71 3.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 65 No Discharge ---- N/A 32.21 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 66 No Discharge ---- N/A 32.32 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Sunday, December 5, 2021, 3:34 PM Fire-Fire Sprinkler Hydraulics Calculation Program, , Elite Software Development,Inc: Condon.Engineering %r' k" 140 Pike Street-Area#3 g Mattituck,"NY.11952 ' s Page 5 Fire Sprinkler Input Data Pipe Input Data Nominal Nominal Fitting Total CFactor Beg. End. Pipe Description Diameter Type Fitting Length Length Length (gpm/inch- Node Node (inch) Group Data (feet) (feet) (feet) psi) 26 27 SCHED 40 STEEL BLK 1.000 0 7.00 0.00 7.00 120 27 51 SCHED 40 STEEL BLK 1.000 0 T 6.00 3.50 9.50 120 28 29 SCHED 40 STEEL BLK 1.000 0 7.00 0.00 7.00 120 29 50 SCHED 40 STEEL BLK 1.000 0 T 6.00 3.50 9.50 120 50 51 SCHED 40 STEEL BLK 2.000 0 10.00 0.00 10.00 120 51 52 SCHED 40 STEEL BLK 2.000 0 2.00 0.00 2.00 120 52 53 SCHED 40 STEEL BLK 2.000 0 12.00 0.00 12.00 120 53 54 SCHED 40 STEEL BLK 2.000 0 T 7.00 7.10 14.10 120 54 55 SCHED 40 STEEL BLK 2.000 0 2.50 0.00 2.50 120 55 56 SCHED 40 STEEL BLK 2.000 0 1.00 0.00 1.00 120 56 58 SCHED 40 STEEL BLK 4.000 0 9.50 0.00 9.50 120 58 59 SCHED 40 STEEL BLK 4.000 0 E 4.00 7.10 11.10 120 59 61 SCHED 40 STEEL BLK 4.000 0 E 12.50 7.10 19.60 120 61 62 SCHED 40 STEEL BLK 4.000 0 E 9.50 7.10 16.60 120 62 63 SCHED 40 STEEL BLK 4.000 0 E 7.50 7.10 14.60 120 63 64 Backflo Prev 7.000 Loss 64 65 SCHED 40 STEEL BLK 4.000 0 E 8.00 7.10 15.10 120 65 66 SCHED 40 STEEL BLK 4.000 0 T 32.00 14.20 46.20 120 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Sunday, December 5, 2021, 3:34 PM Fire=Fire Sprinkler Hydraulics Calculation Program - Elite Software Development,Inc, CondorrEngineering ; 140 Pike Street=Area#3;3 Matti4uck, NY_1.1952 r' f Page 6; Fire Sprinkler Output Data Overall Node Groupings Output Data Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out(+) In (-) Residual Flow At Beg. Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure(psi) Node (gpm) 26 27 0 0.00 19.60 0.00 0.00 12.25 27 26 0 0.00 20.29 0.00 0.00 13.12 0.00450 27 51 0 0.00 28 29 0 0.00 19.50 0.00 0.00 12.13 0.01292 29 28 0 0.00 20.19 0.00 0.00 12.99 -0.00663 29 50 0 0.00 50 29 0 0.00 0.00 0.00 0.00 17.39 50 51 0 0.00 - 51 27 0 0.00 0.00 0.00 0.00 17.56 51 50 0 0.00 51 52 0 0.00 52 51 0 0.00 0.00 0.00 0.00 17.68 52 53 0 0.00 53 52 0 0.00 0.00 0.00 0.00 18.42 53 54 0 0.00 54 53 0 0.00 0.00 0.00 0.00 19.29 54 55 0 0.00 55 54 0 0.00 0.00 0.00 0.00 19.44 55 56 0 0.00 56 55 0 0.00 0.00 0.00 0.00 19.50 56 58 0 0.00 58 56 0 0.00 0.00 0.00 0.00 19.53 58 59 0 0.00 59 58 0 0.00 0.00 0.00 0.00 19.55 59 61 0 0.00 61 59 0 0.00 0.00 0.00 0.00 25.01 61 62 0 0.00 62 61 0 0.00 0.00 0.00 0.00 25.05 62 63 0 0.00 63 62 0 0.00 0.00 0.00 0.00 21.62 63 64 0 0.00 64 63 0 0.00 0.00 0.00 0.00 28.71 64 65 0 0.00 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Sunday, December 5, 2021, 3:34 PM Fire"-Fire Sprinkler Hydraulics Calculation Program �� Elite Software Development,Incl Condon Engineerings 140 Pike Street.-Area#31 Mattituck, NY 11952 ' �: "_ Pa a it Fire Sprinkler Output Data Overall Node Groupings Output Data (cont'd) Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out(+) In (-) Residual Flow At Beg. Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure(psi) Node (gpm) 65 64 0 0.00 0.00 0.00 0.00 32.21 65 66 0 0.00 66 65 0 0.00 0.00 0.00 0.00 32.32 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Sunday, December 5, 2021, 3:34 PM Fire-Fire Sprinkler Hydraulics Calculation Program ; Elite Software Development,Inc.; Condon Engineering ;' 'k i 140 Pike Street-Area#3 Mattituck, NY 11952 r .C Pa e 8, Fire Sprinkler Output Data Overall Pipe Output Data /ft Pipe-Len L q (gpm) F. . . Beg. Nodal Spk/Hose Residual Nom. Dia. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 26 5.60 8.00 19.60 12.25 1.00 0.00 0.12533 7.00 0.877 27 5.60 8.00 20.29 13.12 1.049 19.59 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 7.27 0 7.00 0.877 28 5.60 8.00 19.50 12.13 1.00 0.00 0.12408 7.00 0.869 29 5.60 8.00 20.19 12.99 1.049 19.49 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 7.23 0 7.00 0.869 29 5.60 8.00 20.19 12.99 1.00 0.00 0.46244 6.00 4.393 50 0.00 8.00 0.00 17.39 1.049 39.68 T 3.50 0.000 SCHED 40 STEEL BILK 120 14.73 0 9.50 4.393 27 5.60 8.00 20.29 13.12 1.00 0.00 0.46667 6.00 4.433 51 0.00 8.00 0.00 17.56 1.049 39.88 T 3.50 0.000 SCHED 40 STEEL BLK 120 14.80 0 9.50 4.433 50 0.00 8.00 0.00 17.39 2.00 0.00 0.01700 10.00 0.170 51 0.00 8.00 0.00 17.56 2.067 39.68 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 3.79 0 10.00 0.170 51 0.00 8.00 0.00 17.56 2.00 0.00 0.06158 2.00 0.123 52 0.00 8.00 0.00 17.68 2.067 79.56 ----- 0.00 0.000 SCHED 40 STEEL BILK 120 7.61 0 2.00 0.123 52 0.00 8.00 0.00 17.68 2.00 0.00 0.06158 12.00 0.739 53 0.00 8.00 0.00 18.42 2.067 79.56 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 7.61 0 12.00 0.739 53 0.00 8.00 0.00 18.42 2.00 0.00 0.06158 7.00 0.868 54 0.00 8.00 0.00 19.29 2.067 79.56 T 7.10 0.000 SCHED 40 STEEL BLK 120 7.61 0 14.10 0.868 54 0.00 8.00 0.00 19.29 2.00 0.00 0.06158 2.50 0.154 55 0.00 8.00 0.00 19.44 2.067 79.56 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 7.61 0 2.50 0.154 55 0.00 8.00 0.00 19.44 2.00 0.00 0.06158 1.00 0.062 56 0.00 8.00 0.00 19.50 2.067 79.56 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 7.61 0 1.00 0.062 56 0.00 8.00 0.00 19.50 4.00 0.00 0.00240 9.50 0.023 58 0.00 8.00 0.00 19.53 4.026 79.56 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 2.01 0 9.50 0.023 58 0.00 8.00 0.00 19.53 4.00 0.00 0.00240 4.00 0.027 59 0.00 8.00 0.00 19.55 4.026 79.56 E 7.10 0.000 SCHED 40 STEEL BLK 120 2.01 0 11.10 0.027 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Sunday, December 5, 2021, 3:34 PM Fire-Fire'Sprinkler Hydraulics Calculation Program , :. Elite Software Development,Inc: Coridon Engineering 140 Pike Street-Area#3 Mattituck, NY-11952 Pa?.fara s a 9,$ Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. Nodal Spk/Hose Residual Nom. Dia. G (gpm) F. L./ft Pipe-Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 59 0.00 8.00 0.00 19.55 4.00 0.00 0.00240 12.50 0.047 61 0.00 -4.50 0.00 25.01 4.026 79.56 E 7.10 5.413 SCHED 40 STEEL BLK 120 2.01 0 19.60 5.459 61 0.00 -4.50 0.00 25.01 4.00 0.00 0.00240 9.50 0.040 62 0.00 -4.50 0.00 25.05 4.026 79.56 E 7.10 0.000 SCHED 40 STEEL BLK 120 2.01 0 16.60 0.040 62 0.00 -4.50 0.00 25.05 4.00 0.00 0.00240 7.50 0.035 63 0.00 3.50 0.00 21.62 4.026 79.56 E 7.10 -3.464 SCHED 40 STEEL BLK 120 2.01 0 14.60 -3.429 63 Backflo 3.50 21.62 79.56 Prev 64 7.00 psi 3.50 28.71 64 0.00 3.50 0.00 28.71 4.00 0.00 0.00240 8.00 0.036 65 0.00 -4.50 0.00 32.21 4.026 79.56 E 7.10 3.464 SCHED 40 STEEL BLK 120 2.01 0 15.10 3.500 65 0.00 -4.50 0.00 32.21 4.00 0.00 0.00240 32.00 0.111 66 0.00 -4.50 0.00 32.32 4.026 79.56 T 14.20 0.000 SCHED 40 STEEL BLK 120 2.01 0 46.20 0.111 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Sunday, December 5, 2021, 3:34 PM Fire=Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc:' ..'lam �;�-..: Condon Engineering r 140 Pike Sfreet=-Area#3.q Mattituck,.NY 11952 Pa e.10:{ Fire Sprinkler Output Data Overall Sprinkler Output Data Flowing Area Group Sprinkler Sprinkler Residual Flowing Area Flowing Sprinkler Sprinkler Elevation Pressure Z Density Discharge Node No. Code KFactor(K) (feet) (psi) (ft ) (gpm/f?) (gpm) 26 A 5.60 8.00 12.25 130.00 0.151 19.60 27 A 5.60 8.00 13.12 130.00 0.156 20.29 28 A 5.60 8.00 12.13 130.00 0.150 19.50 29 A 5.60 8.00 12.99 130.00 0.155 20.19 Sub Totals For Group A 520.00 0.153 79.57 Totals For All Groups 520.00 0.153 79.57 C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Sunday, December 5, 2021, 3:34 PM Fire=Fire Sprinkler Hydraulics Calculation Program Elite Software Development,lnc.;. Condon Engineering / x - 140 Pike Street:--A rea#3; Mattituck,NY 11952 . Pa e'11 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number: 28 HMD Actual Residual Pressure: 12.13 psi HMD Actual GPM: 19.50 gpm Sprinkler Summary Sprinkler System Type: Wet Specified Area Of Application: 317.00 ft2 Minimum Desired Density: 0.150 gpm/ft2 Application Average Density: 0.251 gpm/ft2 Application Average Area Per Sprinkler: 79.25 ft2 Sprinkler Flow: 79.57 gpm Average Sprinkler Flow: 19.89 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity( In Pipe 0-0 ) 0.00 ft/sec Maximum Velocity Pressure ( In Pipe 0-0) 0.00 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0056 psi Actual Average Nodal Pressure Imbalance: 0.0028 psi Actual Maximum Nodal Flow Imbalance: 0.0129 gpm Actual Average Nodal Flow Imbalance: 0.0013 gpm Overall Network Summary Number Of Unique Pipe Sections: 18 Number Of Flowing Sprinklers: 4 Pipe System Water Volume: 62.07 gal Sprinkler Flow: 79.57 gpm Non-Sprinkler Flow: 0.00 gpm Demand Flow Excluding Exterior Hose Flow: 79.57 gpm Exterior Hose Flow: 250.00 gpm Minimum Required Residual Pressure At System Inflow 32.32 psi Node: Demand Flow At System Inflow Node: 329.56 gpm C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Sunday, December 5, 2021, 3:34 PM Fire=Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc.:; Condon Engineering � `P _ 140 Pike Street-Area#3 .Mattituck; NY.11952- :Pae 12 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph 100 90 80 U 70 65 ) Q 60 54 W 50 N a` 1 40 4 14 111 30 20 10 0 3 6 9 12 15 18 21 24 27 30 Flowrate(x100) gpm Supply Curve Data Static Pressure: 66 psi Test Residual Pressure: 54 psi Test Flow Rate: 2026 gpm Demand Curve Data Calculated Residual Pressure: 32.32 psi Calculated Flow Rate: 329.56 gpm Exterior Hose Flow: 250.00 gpm Excess Available Residual Pressure At Calculated Flow: 33.26 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 12.41 psi C:\...\Fire Sprinkler Plan 140 Pike Street-Area#3.fiw Sunday, December 5, 2021, 3:34 PM 140 PIKE STREET - AREA#4 REVISED Fire Sprinkler Reports for Peter Marco 140 Pike Street Mattituck, New York Al .x a 05 664 FESSO. Prepared By: John Condon Condon Engineering, P.C. 1755 Sigsbee Road Mattituck, New York 631-298-1986 February 8,2022 r Fire=Fire Sprinkler Hydraulics Calculation Program Elite Software Develo4 pment,Inc. Condon Engineering 140 Pike Street-Area#4'Revi_sed;. 'Mattituck,NY 11952 Pa `e.2,i General Project Data Report General Data Project Title: 140 Pike Street-Area#4 Revised Project File Name: Fire Sprinkler Plan 140 Pike Street- Area#4 Revised..fiw Designed By: John Condon Date: February 8, 2022 Code Reference: NFPA 13 Approving Agency: LOCAL JURISDICTION Client Name: Peter Marco Phone: Address: 140 Pike Street City, State Zip Code: Mattituck, New York Home Address 140 Pike St Mattituck, New York Company Name: Condon Engineering, P.C. Representative: John J. Condon, P.E. Company Address: 1755 Sigsbee Road City And State: Mattituck, New York Phone: 631-298-1986 Building Name: 140 Pike Street Building Owner: Contact at Building: Peter Marco Phone at Building: Address Of Building: 140 Pike Street City, State Zip Code: Mattituck, New York 11952 Project Data Description Of Hazard: NFPA 13 Sprinkler System Type: Wet Design Area Of Water Application: 771 ft2 Maximum Area Per Sprinkler: 130 ft2 Default Sprinkler K-Factor: 5.60 K Default Pipe Material: SCHED 40 STEEL BLK Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 250.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: Reliable Model: G5 Size: 1/2 Temperature Rating: 165 F NONE Water Supply Test Data Source Of Information: SCWA Test Hydrant ID: 820068000 Date Of Test: 11-22-2021 Hydrant Elevation: 0 ft Static Pressure: 66.00 psi Test Flow Rate: 2026.00 gpm Test Residual Pressure: 54.00 psi Calculated System Flow Rate: 433.19 gpm Calculated Inflow Residual Pressure: 47.54 psi Available Residual Pressure At 65.31 psi System Flow: Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 7.00 psi Minimum Desired Flow Density: 0.10 gpm/ft2 Maximum Water Velocity: 20.00 ft/s Maximum Frictional Loss/ 100 feet: 20.00 psi Number Of Active Nodes: 32 Number Of Active Pipes: 31 Number Of Inactive Pipes: 0 Number Of Active Sprinklers: 11 Number Of Inactive Sprinklers: 0 C:\...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM Fire=Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc..j Condon Engineering fr 140 Pike Street:-Area#4.Revised-I Mattituck,NY 11952 . Page 31 Fire Sprinkler Input Data Node Input Data Area Group Sprinkler Pressure Node Elev(ft) Non-Sprinkler Node Node Description Branch Dia. KFactor(K) Estimate(psi) Branch Non- Flow(gpm) No. Branch Description (in) Branch Len. Branch Stnd Stnd Fittings Branch Sprk (ft) Fittings (ft) KFactor(K) 23 Sprinkler A 5.60 7.00 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 24 Sprinkler A 5.60 7.71 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 25 Sprinkler A 5.60 10.65 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 26 Sprinkler A 5.60 11.34 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 27 Sprinkler A 5.60 7.67 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 28 No Discharge ---- N/A 7.71 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 29 Sprinkler A 5.60 11.47 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 30 Sprinkler A 5.60 9.85 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 31 Sprinkler A 5.60 8.43 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 32 Sprinkler A 5.60 8.51 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 33 Sprinkler A 5.60 7.92 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 34 Sprinkler A 5.60 7.44 17.00 0.00 0.000 0.0 ---- 0.0 0.00 39 No Discharge ---- N/A 8.04 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 40 No Discharge ---- N/A 8.38 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 41 No Discharge ---- N/A 9.00 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 42 No Discharge ---- N/A 9.89 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 C:\...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM Fire-Fire Sprinkler Hydraulics Calculation Program k . Elite Software`Development;Inc.;j Condon Engineering 140 Pike Street-Are a#4 Revised Mattituck,NY'11952 Page 4. Fire Sprinkler Input Data Node Input Data (cont'd) Area Group Sprinkler Pressure Node Elev(ft) Non-Sprinkler Node Node Description Branch Dia. KFactor(K) Estimate(psi) Branch Non- Flow(gpm) No. Branch Description (in) Branch Len. Branch Stnd Stnd Fittings Branch Sprk _ (ft) Fittings (ft) KFactor(K) 43 No Discharge ---- N/A 11.13 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 44 No Discharge ---- N/A 11.43 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 45 No Discharge ---- N/A 12.04 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 46 No Discharge ---- N/A 13.13 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 47 No Discharge ---- N/A 12.18 17.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 48 No Discharge ---- N/A 22.67 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 49 No Discharge ---- N/A 26,28 8.00 0.00 --- 0.000 0.0 ---- 0.0 0.00 57 No Discharge ---- N/A 28.61 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 58 No Discharge ---- N/A 28.69 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 59 No Discharge ---- N/A 28.82 8.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 61 No Discharge ---- N/A 34.45 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 62 No Discharge ---- N/A 34.64 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 63 No Discharge ---- N/A 31.34 3.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 64 No Discharge ---- N/A 43.38 3.50 0.00 ---- 0.000 0.0 --- 0.0 0.00 65 No Discharge ---- N/A 47.02 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 66 No Discharge ---- N/A 47.54 -4.50 0.00 ---- 0.000 0.0 ---- 0.0 0.00 C:\...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM �Fir®:Fiie Sprinkler Hydraulics Calculation Program .: Elite,Software Development;,Inc:: Condon Engineering., " 140 Pike;Street-Area#4 Revised ,`Mattit6ck,`NY.11952 Pa a 5.:; Fire Sprinkler Input Data Pipe Input Data Nominal Nominal Fitting Total CFactor Beg. End. Pipe Description Diameter Type Fitting Length Length Length (gpm/inch- Node Node (inch) Group Data (feet) (feet) (feet) psi) 23 28 SCHED 40 STEEL BLK 1.000 0 T 6.00 3.50 9.50 120 24 39 SCHED 40 STEEL BLK 1.000 0 4.00 0.00 4.00 120 25 44 SCHED 40 STEEL BLK 1.000 0 T 3.50 3.50 7.00 120 26 45 SCHED 40 STEEL BLK 1.000 0 T 2.50 3.50 6.00 120 27 28 SCHED 40 STEEL BLK 1.000 0 0.50 0.00 0.50 120 28 47 SCHED 40 STEEL BLK 1.000 0 E 14.50 1.40 15.90 120 29 47 SCHED 40 STEEL BLK 1.000 0 T 2.50 3.50 6.00 120 30 43 SCHED 40 STEEL BLK 1.000 0 T 9.00 3.50 12.50 120 31 42 SCHED 40 STEEL BLK 1.000 0 ET 11.50 4.90 16.40 120 32 41 SCHED 40 STEEL BLK 1.000 0 T 2.00 3.50 5.50 120 33 40 SCHED 40 STEEL BLK 1.000 0 T 2.00 3.50 5.50 120 34 39 SCHED 40 STEEL BLK 1.000 0 T 4.00 3.50 7.50 120 39 40 SCHED 40 STEEL BLK 1.500 0 T 4.00 5.60 9.60 120 40 41 SCHED 40 STEEL BLK 1.500 0 8.00 0.00 8.00 120 41 42 SCHED 40 STEEL BLK 1.500 0 T 1.00 5.60 6.60 120 42 43 SCHED 40 STEEL BLK 1.500 0 6.00 0.00 6.00 120 43 44 SCHED 40 STEEL BLK 1.500 0 1.00 0.00 1.00 120 44 45 SCHED 40 STEEL BLK 1.500 0 1.50 0.00 1.50 120 45 46 SCHED 40 STEEL BLK 1.500 0 2.00 0.00 2.00 120 47 46 SCHED 40 STEEL BLK 1.500 0 T 5.50 5.60 11.10 120 46 48 SCHED 40 STEEL BLK 1.500 0 E 3.00 2.80 5.80 120 48 49 SCHED 40 STEEL BLK 2.000 0 E 9.00 3.50 12.50 120 49 57 SCHED 40 STEEL BLK 2.000 0 T 1.00 7.10 8.10 120 57 58 SCHED 40 STEEL BLK 4.000 0 7.50 0.00 7.50 120 58 59 SCHED 40 STEEL BLK 4.000 0 E 4.00 7.10 11.10 120 C:\...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM �.fire .Fir_e= Sprinkler Hydraulics Calculation Program Elite Software Development;lnc. Cndon Engineering ` 140.Pike Street-Area#4 Revised Mattituck,NY 11952 ?. Pa e,6± Fire Sprinkler Input Data Pipe Input Data (cont'd) Nominal Nominal Fitting Total CFactor Beg. End. Pipe Description Diameter Type Fitting Length Length Length (gpm/inch- Node Node (inch) Group Data (feet) (feet) (feet) psi) 59 61 SCHED 40 STEEL BLK 4.000 0 E 12.50 7.10 19.60 120 61 62 SCHED 40 STEEL BLK 4.000 0 E 9.50 7.10 16.60 120 62 63 SCHED 40 STEEL BLK 4.000 0 E 7.50 7.10 14.60 120 63 64 Backflo Prev 12.000 Loss 64 65 SCHED 40 STEEL BLK 4.000 0 E 8.00 7.10 15.10 120 65 66 SCHED 40 STEEL BLK 4.000 0 T 32.00 14.20 46.20 120 CA...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM Elite Software Development,Inc:A Fire Fire Sprinkler Hydraulics Calculation Program ' . Mattituck NY 11r952. � 140 Pike Street-Area#4 Revised Page-7 Fire Sprinkler Output Data Overall Node Groupings Output Data Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out(+) In (-) Residual Flow At Beg. Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure(psi) Node (gpm) 23 28 0 -14.82 14.82 0.00 0.00 7.00 24 39 0 -15.55 15.55 0.00 0.00 7.71 0.00000 25 44 0 -18.28 18.28 0.00 0.00 10.65 0.00000 26 45 0 -18.86 18.86 0.00 0.00 11.34 0.00000 27 28 0 -15.51 15.51 0.00 0.00 7.67 0.00000 28 23 0 14.82 0.00 0.00 0.00 7.71 0.00000 28 27 0 15.51 28 47 0 -30.32 29 47 0 -18.97 18.97 0.00 0.00 11.47 0.00000 30 43 0 -17.57 17.57 0.00 0.00 9.85 0.00000 31 42 0 -16.26 16.26 0.00 0.00 8.43 0.00000 32 41 0 -16.34 16.34 0.00 0.00 8.51 0.00000 33 40 0 -15.76 15.76 0.00 0.00 7.92 0.00000 34 39 0 -15.28 15.28 0.00 0.00 7.44 0.00000 39 24 0 15.55 0.00 0.00 0.00 8.04 0.00000 39 34 0 15.28 39 40 0 -30.83 40 33 0 15.76 0.00 0.00 0.00 8.38 0.00000 40 39 0 30.83 40 41 0 -46.59 41 32 0 16.34 0.00 0.00 0.00 9.00 0.00000 41 40 0 46.59 41 42 0 -62.93 42 31 0 16.26 0.00 0.00 0.00 9.89 0.00000 42 41 0 62.93 42 43 0 -79.19 43 30 0 17.57 0.00 0.00 0.00 11.13 0.00000 43 42 0 79.19 43 44 0 -96.76 44 25 0 18.28 0.00 0.00 0.00 11.43 0.00000 44 43 0 96.76 44 45 0 -115.04 C:1...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM Fire,- P .Fire Sprinkler Hydraulics Calculation Program .f .4{. Elite Software Develo Ment;Inc:; Condon Engineering " 140 Pike Street:=Area#4 Revised ,Mattituck,'NY 11952. .' - "Pa`e•8 Fire Sprinkler Output Data Overall Node Groupings Output Data (cont'd) Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out(+) In (-) Residual Flow At Beg. _ Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure (psi) Node(gpm) 45 26 0 18.86 0.00 0.00 0.00 12.04 0.00000 45 44 0 115.04 45 46 0 -133.90 46 45 0 133.90 0.00 0.00 0.00 13.13 0.00000 46 47 0 49.29 46 48 0 -183.19 47 28 0 30.32 0.00 0.00 0.00 12.18 0.00000 47 29 0 18.97 47 46 0 -49.29 48 46 0 183.19 0.00 0.00 0.00 22.67 0.00000 48 49 0 -183.19 49 48 0 183.19 0.00 0.00 0.00 26.28 0.00000 49 57 0 -183.19 57 49 0 183.19 0.00 0.00 0.00 28.61 0.00000 57 58 0 -183.19 58 57 0 183.19 0.00 0.00 0.00 28.69 0.00000 58 59 0 -183.19 59 58 0 183.19 0.00 0.00 0.00 28.82 0.00000 59 61 0 -183.19 61 59 0 183.19 0.00 0.00 0.00 34.45 0.00000 61 62 0 -183.19 62 61 0 183.19 0.00 0.00 0.00 34.64 0.00000 62 63 0 -183.19 63 62 0 183.19 0.00 0.00 0.00 31.34 0.00000 63 64 0 -183.19 64 63 0 183.19 0.00 0.00 0.00 43.38 0.00000 64 65 0 -183.19 65 64 0 183.19 0.00 0.00 0.00 47.02 0.00000 65 66 0 -183.19 66 65 0 183.19 0.00 0.00 -183.19 47.54 CA...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM Fire,-Fide Sprinkler Hydraulics Calculation Program' Elite Software Developrrieni;Inc:,', CoEngineering " 140 Pike Street,-Area#4 Reviseds' Maftituck,,NY 11952 t:. ....': Pa e,9.1 Fire Sprinkler Output Data Overall Pipe Output Data Beg. Nodal Spk/Hose Residual . Nom. Dia. q (gpm) F. L./ft Pipe-Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 23 5.60 17.00 14.82 7.00 1.00 14.82 0.07473 6.00 0.710 28 0.00 17.00 0.00 7.71 1.049 14.82 T 3.50 0.000 SCHED 40 STEEL BLK 120 5.50 0 9.50 0.710 27 5.60 17.00 15.51 7.67 1.00 15.51 0.08132 0.50 0.041 28 0.00 17.00 0.00 7.71 1.049 15.51 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 5.76 0 0.50 0.041 24 5.60 17.00 15.55 7.71 1.00 15.55 0.08172 4.00 0.327 39 0.00 17.00 0.00 8.04 1.049 15.55 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 5.77 0 4.00 0.327 34 5.60 17.00 15.28 7.44 1.00 15.28 0.07911 4.00 0.593 39 0.00 17.00 0.00 8.04 1.049 15.28 T 3.50 0.000 SCHED 40 STEEL BLK 120 5.67 0 7.50 0.593 33 5.60 17.00 15.76 7.92 1.00 15.76 0.08379 2.00 0.461 40 0.00 17.00 0.00 8.38 1.049 15.76 T 3.50 0.000 SCHED 40 STEEL BLK 120 5.85 0 5.50 0.461 39 0.00 17.00 0.00 8.04 1.50 0.00 0.03599 4.00 0.346 40 0.00 17.00 0.00 8.38 1.610 30.83 T 5.60 0.000 SCHED 40 STEEL BLK 120 4.86 0 9.60 0.346 32 5.60 17.00 16.34 8.51 1.00 16.34 0.08952 2.00 0.492 41 0.00 17.00 0.00 9.00 1.049 16.34 T 3.50 0.000 SCHED 40 STEEL BLK 120 6.06 0 5.50 0.492 40 0.00 17.00 0.00 8.38 1.50 0.00 0.07727 8.00 0.618 41 0.00 17.00 0.00 9.00 1.610 46.59 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 7.34 0 8.00 0.618 31 5.60 17.00 16.26 8.43 1.00 16.26 0.08879 11.50 1.456 42 0.00 17.00 0.00 9.89 1.049 16.26 ET 4.90 0.000 SCHED 40 STEEL BLK 120 6.04 0 16.40 1.456 41 0.00 17.00 0.00 9.00 1.50 0.00 0.13474 1.00 0.889 42 0.00 17.00 0.00 9.89 1.610 62.93 T 5.60 0.000 SCHED 40 STEEL BLK 120 9.92 0 6.60 0.889 30 5.60 17.00 17.57 9.85 1.00 17.57 0.10247 9.00 1.281 43 0.00 17.00 0.00 11.13 1.049 17.57 T 3.50 0.000 SCHED 40 STEEL BLK 120 6.52 0 12.50 1.281 42 0.00 17.00 0.00 9.89 1.50 0.00 0.20616 6.00 1.237 43 0.00 17.00 0.00 11.13 1.610 79.19 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 12.48 0 6.00 1.237 CA...\Fire Sprinki ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM Fire.=F46,Sprinkler Hydraulics Calculation Program ;' Elite:Software Development;Inc:« Condon`Engirieering. ' tr 140 Pike Street-Area#4. Revised'j Ma4tifuck•;AY 11952 �; + Pa e,10, Fire Sprinkler Output Data ;Overall Pipe Output Data (cont°d) Beg. Nodal Spk/Hose Residual NoDia. q (gpm) F. L./ft Pipe-Len. PF-(psi) Elevation m. Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 25 5.60 17.00 18.28 10.65 1.00 18.28 0.11022 3.50 0.772 44 0.00 17.00 0.00 11.43 1.049 18.28 T 3.50 0.000 SCHED 40 STEEL BLK 120 6.79 0 7.00 0.772 43 0.00 17.00 0.00 11.13 1.50 0.00 0.29870 1.00 0.299 44 0.00 17.00 0.00 11.43 1.610 96.76 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 15.25 0 1.00 0.299 26 5.60 17.00 18.86 11.34 1.00 18.86 0.11679 2.50 0.701 45 0.00 17.00 0.00 12.04 1.049 18.86 T 3.50 0.000 SCHED 40 STEEL BLK 120 7.00 0 6.00 0.701 44 0.00 17.00 0.00 11.43 1.50 0.00 0.41141 1.50 0.617 45 0.00 17.00 0.00 12.04 1.610 115.04 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 18.13 0 1.50 0.617 45 0.00 17.00 0.00 12.04 1.50 0.00 0.54482 2.00 1.090 46 0.00 17.00 0.00 13.13 1.610 133.90 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 21.10 0 2.00 1.090 47 0.00 17.00 0.00 12.18 1.50 0.00 0.08576 5.50 0.952 46 0.00 17.00 0.00 13.13 1.610 49.29 T 5.60 0.000 SCHED 40 STEEL BLK 120 7.77 0 11.10 0.952 28 0.00 17.00 0.00 7.71 1.00 0.00 0.28119 14.50 4.471 47 0.00 17.00 0.00 12.18 1.049 30.32 E 1.40 0.000 SCHED 40 STEEL BLK 120 11.26 0 15.90 4.471 29 5.60 17.00 18.97 11.47 1.00 18.97 0.11803 2.50 0.708 47 0.00 17.00 0.00 12.18 1.049 18.97 T 3.50 0.000 SCHED 40 STEEL BLK 120 7.04 0 6.00 0.708 46 0.00 17.00 0.00 13.13 1.50 0.00 0.97299 3.00 5.643 48 0.00 8.00 0.00 22.67 1.610 183,19 E 2.80 3.897 SCHED 40 STEEL BLK 120 28.87 0 5.80 9.540 48 0.00 8.00 0.00 22.67 2.00 0.00 0.28817 9.00 3.602 49 0.00 8.00 0.00 26.28 2.067 183.19 E 3.50 0.000 SCHED 40 STEEL BLK 120 17.52 0 12.50 3.602 49 0.00 8.00 0.00 26.28 2.00 0.00 0.28817 1.00 2.334 57 0.00 8.00 0.00 28.61 2.067 183.19 T 7.10 0.000 SCHED 40 STEEL BLK 120 17.52 0 8.10 2.334 57 0.00 8.00 0.00 28.61 4.00 0.00 0.01121 7.50 0.084 58 0.00 8.00 0.00 28.69 4.026 183.19 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 4.62 0 7.50 0.084 CA...Wire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM Fire Fire Sprinkler Hydraulics Calculation„Program 7 Elite Software Development ln'c ;Condon'Engineering " ,140 Pike Street=Area#4,Revised 4.Mattituck;NY 11952 Pa e 1;1:,i Fire Sprinkler Output Data :,'Overall Pipe Output Data (cont'd) Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe-Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 58 0.00 8.00 0.00 28.69 4.00 0.00 0.01121 4.00 0.124 59 0.00 8.00 0.00 28.82 4.026 183.19 E 7.10 0.000 SCHED 40 STEEL BLK 120 4.62 0 11.10 0.124 59 0.00 8.00 0.00 28.82 4.00 0.00 0.01121 12.50 0.220 61 0.00 -4.50 0.00 34.45 4.026 183.19 E 7.10 5.413 SCHED 40 STEEL BLK 120 4.62 0 19.60 5.632 61 0.00 -4.50 0.00 34.45 4.00 0.00 0.01121 9.50 0.186 62 0.00 -4.50 0.00 34.64 4.026 183.19 E 7.10 0.000 SCHED 40 STEEL BLK 120 4.62 0 16.60 0.186 62 0.00 -4.50 0.00 34.64 4.00 0.00 0.01121 7.50 0.164 63 0.00 3.50 0.00 31.34 4.026 183.19 E 7.10 -3.464 SCHED 40 STEEL BLK 120 4.62 0 14.60 -3.300 63 Backflo 3.50 31.34 183.19 Prev 64 12.00 psi 3.50 43.38 64 0.00 3.50 0.00 43.38 4.00 0.00 0.01121 8.00 0.169 65 0.00 -4.50 0.00 47.02 4.026 183.19 E 7.10 3.464 SCHED 40 STEEL BLK 120 4.62 0 15.10 3.633 65 0.00 -4.50 0.00 47.02 4.00 0.00 0.01121 32.00 0.518 66 0.00 -4.50 0.00 47.54 4.026 183.19 T 14.20 0.000 SCHED 40 STEEL BLK 120 4.62 0 46.20 0.518 C:\...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM 'Fire"-Fire Sprinkler Hydraulics Calculation Program Elite Software Development;.lnc. Coridori Engineering 140 Pike Street-Area#,4 Revis6d ;Mattifuck, ,NY,11952 Pae 12'! Fire Sprinkler Output Data Overall Sprinkler Output Data Flowing Area Group Sprinkler Sprinkler Residual Flowing Area Flowing Sprinkler Sprinkler Elevation Pressure 2 Density Discharge Node No. Code KFactor(K) (feet) (psi) (ft ) (gpm/ft2) (gpm) 23 A 5.60 17.00 7.00 130.00 0.114 14.82 24 A 5.60 17.00 7.71 130.00 0.120 15.55 25 A 5.60 17.00 10.65 130.00 0.141 18.28 26 A 5.60 17.00 11.34 130.00 0.145 18.86 27 A 5.60 17.00 7.67 130.00 0.119 15.51 29 A 5.60 17.00 11.47 130.00 0.146 18.97 30 A 5.60 17.00 9.85 130.00 0.135 17.57 31 A 5.60 17.00 8.43 130.00 0.125 16.26 32 A 5.60 17.00 8.51 130.00 0.126 16.34 33 A 5.60 17.00 7.92 130.00 0.121 15.76 34 A 5.60 17.00 7.44 130.00 0.118 15.28 Sub Totals For Group A 1430.00 0.128 183.19 Totals For All Groups 1430.00 0.128 183.19 C:\...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM Fire;=Flee Sprinkler Calculation Program :: Elite Software Development,Inc71 ; Condon Engineering•, 140 Pike Street.-Area#4 Revised` Ma'ttituck;NY 1.1952 r ti Page,13 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number: 23 HMD Actual Residual Pressure: 7.00 psi HMD Actual Flow: 14.82 gpm Sprinkler Summary Sprinkler System Type: Wet Specified Area Of Application: 771.00 ft2 Minimum Desired Density: 0.100 gpm/ft2 Application Average Density: 0.238 gpm/ft2 Application Average Area Per Sprinkler: 70.09 ft2 Sprinkler Flow: 183.19 gpm Average Sprinkler Flow: 16.65 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity( In Pipe 46-48) 28.87 ft/sec Maximum Velocity Pressure( In Pipe 46-48) 5.61 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0000 psi Actual Average Nodal Pressure Imbalance: 0.0000 psi Actual Maximum Nodal Flow Imbalance: 0.0000 gpm Actual Average Nodal Flow Imbalance: 0.0000 gpm Overall Network Summary Number Of Unique Pipe Sections: 31 Number Of Flowing Sprinklers: 11 Pipe System Water Volume: 61.48 gal Sprinkler Flow: 183.19 gpm Non-Sprinkler Flow: 0.00 gpm Demand Flow Excluding Exterior Hose Flow: 183.19 gpm Exterior Hose Flow: 250.00 gpm Minimum Required Residual Pressure At System Inflow 47.54 psi Node: Demand Flow At System Inflow Node: 433.19 gpm C:\...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM r ^ "Fire;Fire Sprinkler Hydraulics Calculation Program ",�- ,. Elite Software Development,lnc i Condon•Engineering 140 Pike Street-Area#4 Revised M'attifdck,NY 11952 " Pa erA41 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph 100 90 80 .N 70 Q. 60 � 54 � 50 N a 1 40 30 20 10 0 3 6 9 12 15 18 21 24 27 30 Flowrate(x100) gpm Supply Curve Data Static Pressure: 66 psi Test Residual Pressure: 54 psi Test Flow Rate: 2026 gpm Demand Curve Data Calculated Residual Pressure: 47.54 psi Calculated Flow Rate: 433.19 gpm Exterior Hose Flow: 250.00 gpm Excess Available Residual Pressure At Calculated Flow: 17.77 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 21.31 psi C:\...\Fire Sprinkl ... Revised.fiw Tuesday, February 8, 2022, 3:22 PM Bulletin 034 February 2021 HIMImlabld Model G5 Series Sprinklers Standard Spray, Flat Concealed Pendent Available with Gasketed Cover Plate Features • Standard Coverage,Concealed Pendent(K2.8,4.2,5.6,&8.0 [40,60,80,&115 metric]) ; • Flat concealed cover plate available in a variety of finishes. IN • Available with Stainless Steel Clad cover plate(see Table 1). • 3/4-inch(19 mm)cover plate adjustment. • Cover plate available with optional gasket. Model G5 Cover Plate Model G5 Cover Plate Product Description with QR Gasket Model G5 series sprinklers are standard coverage,flat plate concealed sprinklers designed for installation in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets.All Model G5 series sprinklers use a fusible-link operating element. The sprinklers are offered with a standard Model G5 cover plate, a Model G5 cover plate with a quick-response(QR)gasket,or a Model G5 cover plate with a standard-response(SR)gasket.Model ' G5 sprinklers with a gasketed cover plate are intended for use in Model G5 Cover Plate dust free environments such as clean rooms. with SR Gasket Model G5 sprinklers must only be,used with the Model G5 cover Note:Gasket material is silicone rubber,available in white only. plate listed or approved with the sprinkler.Table A provides a summary of available Model G5 series sprinklers,along with Listing and Approval information for each sprinkler and cover plate combination. Model G5 Series Sprinkler Summary K-Factor Listings Max.Working Sprinkler Sprinkler gpm/psi"Z Cover Plate and Sensitivity Pressure Identification Model (L/min/bar'/2) Model Approvals psi(bar) Number(SIN) G5 cULus QR G5-28 (40) G5 QR Gasket cULus QR FM SR 175(12) RA3411 G5 SR Gasket cULus, FM SR G5 G5-42 (60) G5 QR Gasket cULus QR 175(12) RA3413 G5 SR Gasket cULus SR G5 cULus QR 250(17) FM, LPCB,VdS,CE SR 175(12) G5-56 (80) G5 QR Gasket cULus QR 250(17) RA3415 G5 SR Gasket cULus SR 250(17) FM SR 175(12) G5 G5-56 300 (80) G5 QR Gasket cULus QR 300(21) RA4014 G5 SR Gasket cULus SR G5 G5-80 (815) G5 QR Gasket cULus QR 175(12) RA3412 G5 SR Gasket cULus SR G5-80F (8.0 G5 SR Gasket FM SR 175(12) RA3417 www.reliablesprinkler.com f 1 Model G5-28 Standard Coverage,Concealed Pendent Sprinkler SIN RA34V Technical Specifications Sprinkler Temperature Ratings =µ ,`• , Style:Flat Concealed Pendent 165°F(74°C) Threads:112"NPT or ISO 7-1 R1/2 212°F(100°C) Nominal K-Factor:2.8(40 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) (See Table B) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 OR Gasket(cULus only) Levers:Bronze Allo ` Y Model G5 SR Gasket ..�%�,�. Yoke:Brass Alloy Sealing washer:Nickel with PTFE Cover Plate Finishes Load Screw:Bronze Alloy (See Table I) Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model W3 £ Deflector:Bronze Alloy Model FC $Mx Cup:Steel Listings and Approvals . cULus Listed(Light Hazard only) FM Approved Model G5-28 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower Fusible Link I 3/4"(19 mm)Max. Deflector(retracted) �. ;; Cover Plate Adjustment3/16"(5 mm) Pin(extended) Deflector(extended)---- _ _ Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-28 Sprinkler Sensitivity Cover Plate Model Listing or Approval Agency cULus FM G5 OR SR G5 OR Gasket OR -- G5 SR Gasket SR SR QR:Quick-response SR:Standard-response Bulletin 034 Page 2 of 9 February 2021 Rellable www.reliablesprinkler.com Model G5-42 Standard Coverage,Concealed Pendent Sprinkler SIN RA3413 Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) Threads:1/z"NPT or ISO 7-1 R1/2 212°F(100°C) Nominal K-Factor:4.2(60 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) (See Table C) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 QR Gasket Levers:Bronze Alloy Model G5 SR Gasket Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE (See Table 1) Load Screw:Bronze Alloy Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light Hazard only) —Model G5-42 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower Fusible Link I1 3/4"(19 mm)Max. Deflector(retracted) ;; 3/16"(5 mm) Cover Plate Adjustment Pin(extended) Deflector(extended) Model G4/G5 Cover Plate—Z/F-3-5/16"(84 mm)Dia. \—Ceiling Model G5-42 Sensitivity Listing or Approval Agency Cover Plate Model cULus G5 QR G5 QR Gasket QR G5 SR Gasket SIR QR: Quick-response SR:Standard-response Bulletin 034 Page 3 of 9 February 2021 Reliabld www.reliablesprinkler.com r Model . Coverage, • .ent Sprinkler SIN RA3415 • Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) paY".. '• ,. Threads:1/2"NPT or ISO 7-1 R1/2 212°F(100°C)(cULus,FM,LPCB,CE only) Nominal K-Factor:5.680 metric ( ) Sensitivity Max.Working Pressure: (See Table D) 175 psi(12 bar) 250 psi(17 bar)(cULus only) Cover Plates Model G5 Material Specifications Model G5 QR Gasket(cULus only) Fusible Link:Beryllium Nickel Model G5 SR Gasket(cULus and FM only) ?=F Sprinkler Body:Brass Alloy i Cover Plate Finishes Levers:Bronze Alloy •� ;�:,�:�^"` Yoke:Brass Alloy (See Table I) Sealing washer:Nickel with PTFE Sprinkler Wrench Load Screw:Bronze Alloy Model W3 Towers:Copper Alloy Model FC Pins:Stainless Steel Listings and Approvals Deflector:Bronze Alloy cULus Listed(Light&Ordinary Hazard only) Cup:Steel FM Approved LPCB Approved VdS Approved[165°F(74°C)only] CE Listed(2831-CPR-S2062) Model G5-56 Sprinkler Components and Dimensions �• 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling ... Tower Fusible Link 3/4"(19 mm)Max. - x 3/16"(5 mm) Deflector(retracted) Cover Plate Adjustment 1 1 ....... Pin(extended) Deflector(extended) Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-56 Sensitivity Listing or Approval Agency Cover Plate Model cULus FM LPCB,VdS,CE G5 QR SR SR G5 QR Gasket QR - -- G5 SR Gasket SR SR - QR: Quick-response SR:Standard-response Bulletin 034 Page 4 of 9 February 2021 Reliable www.reliablesprinkler.com x Model G5-56 00 Standard Coverage,Concealed Pendent Sprinkler SIN RA4014 Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165'F(74°C) µ:' `• Threads: /z"NPT or ISO 7-1 R1/2 212-F(100°C) ? - Nominal K-Factor:5.6(80 metric) Sensitivity Max.Working Pressure:300 psi(21 bar) (See Table E) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 QR Gasket „x.., Levers:Bronze Alloy Model G5 SR Gasketm ~ Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE Load Screw:Bronze Alloy (See Table 1) Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light&Ordinary Hazard only) Model G5756 300 Sprinkler Components and Dimensions 2-5/16” (58 mm) Dia. Threads Body Cup Ceiling Tower Fusible Link 3/4"(19 mm)Max. Deflector(retracted) I Cover Plate Adjustment ;;;;;;; 3/16"(5 mm) ....... Pin(extended) Deflector(extended) 4Z. Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-56 300 Sensitivity Listing or Approval Agency Cover Plate Model cULus 77 G5 QR G5 QR Gasket QR G5 SR Gasket SR QR:Quick-response SR:Standard-response c Bulletin 034 Reliable Page 5 of 9 February 2021 www.reliablespr.inkler.com F Model G5-80Standard Coverage, • - Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) •..:.m Threads:3/a"NPT or ISO 7-1 R3/4 212°F(100°C) Nominal K-Factor:8.0(115 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) (See Table F) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 QR Gasket Levers:Bronze Alloy Model G5 SR Gasket Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE Load Screw:Bronze Alloy (See Table Wrench Towers:Copper Alloy Sprinkler Wr Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light&Ordinary Hazard only) Model G5-80 Sprinkler Components and Dimensions ' 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower ��,,,�, Fusible Link 3/4"(19 mm)Max. Deflector(retracted) �.; ;; Cover Plate Adjustment 3/16"(5 mm) ....... Pin(extended) ; Deflector(extended) Model G4/G5 Cover Plate 3 5/16"(84 mm)Dia. Ceiling Model G5-80 Sensitivity Listing or Approval Agency Cover Plate Model cULus G5 QR G5 QR Gasket QR G5 SR Gasket SR QR: Quick-response SR:Standard-response Bulletin 034 Reliable Page 6 of 9 February 2021 www.relia6lesprinkler.com Model GS-80F Standard Coverage,Concealed Pendent Sprinkler SIN RA3417 Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165-F(74°C) Threads:3/4"NPT or ISO 7-1 R3/4 212°F(100°C) Nominal K-Factor:8.0(115 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) Standard Response Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 SR Gasket Levers:Bronze Alloy Cover Plate Finishes Yoke:Brass Alloy (See Table 1) Sealing washer:Nickel with PTFE Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model W3 Pins:Stainless Steel Model FC £, Deflector:Stainless Steel Listings and Approvals Cup:Steel FM Approved Model G5-80F Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower Fusible Link 3/4"(19 mm)Max. Deflector(retracted) ; Cover Plate Adjustment 3/16"(5 mm) .... Pin(extended) Deflector(extended) — -=-a��--_ Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. V,Ceiling Model G5-80F Sensitivity Listing or Approval Agency Cover Plate Model FM 77 G5 SR GSSR Gasket SR SR:Standard-response Bulletin 034 Page 7 of 9 February 2021 Reliable www.reliablesprinkler.com l Installation Dimensions and Cover Plate Information 51 Min.to Max. Min.to Max. Cover Plate Recommended Cover Plate Face of Fitting Dropped Cover Plate Cover Plate Diameter Hole Diameter in Adjustment to Deflector Temperature Ceiling Distance Rating Model Inch Inch Ceilingt'> (mm) Inch (mm) Inch below Ceiling °F (mm) (mm) Inch (°C) mm G5 3-5/16 (84) 135°F 3 3-11/16 (57°C) G5 QR Gasket(2) (94) 2-5/6 3/4 1-1/2 to 2-1/4 1/4 to 1 (67) (19) (38 to 57) (6 to 25) or G5 SR Gasket(') 4 165°F(4) (101 mm) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on nominal thread make up.Verify dimensions based on fitting and thread sealing method prior to installation.A'/2"x 1/2°brass nipple extension(Reliable P/N 6999991900)is available to assist with replacement of Reliable Model G4A sprinklers. 2. Model G5 QR Gasket and Model G5 SR Gasket cover plates are sold as assembled units including both the cover plate and gasket.Model G5 QR Gasket and Model G5 SR Gasket cover plates and gaskets are not interchangeable. 3. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). 4. For use with 212°F(100°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F(66°C). Cover Plate Finishes(l)I2) _ Standard Finishes Special Application Finishes Listing &Approval Agencies White Paint Off-White Paint Individual Model G5 series sprinkler may be listed or approved by Chrome^) Black Paint the following agencies: Custom Color Paint(Specify)(') Underwriters Laboratories, Inc.and UL Canada(cULus) Raw Brass(Lacquered) Listing Category:Sprinklers,Automatic and Open Bright Brass0) Guide Number: NIV p Finished Bronze ^> FMApprovals(FM) Black Plated ^� Loss Prevention Crtification BoardLPCB Satin Chrome ( ) Stainless Steel Clad(5) VdS Schadenverhiitung GmbH (VdS) • EC-Certificate of Conformity 0832-CPD-2062(CE) Notes: See Table A and the individual sprinkler data sheets in this Bulletin 1. Paint or any other coating applied over the factory finish will void all for listings and approvals applicable to each sprinkler. approvals and warranties. 2. Cover plates do not carry corrosion resistant listings or approvals. 3. Custom color paint is semi-gloss unless specified otherwise. 4. Not listed for use with QR sealing gasket. Installation 5. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Alloy on the back side. Model G5 series sprinklers are intended to be installed in accordance with NFPA 13, FM Global Property Loss Prevention Application Data Sheets,and the requirements of applicable authorities having jurisdiction. Model G5 series sprinklers must not be Model G5 series sprinklers are standard coverage,flat plate installed in ceilings with positive pressure in the space above. concealed pendent sprinklers.The sprinklers are intended for Ensure that the 4 slots in the cup are open and unobstructed use in accordance with NFPA 13 and FM Global Property Loss following installation. Prevention Data Sheets,as well as the requirements of the Model G5 series sprinklers are shipped with a wrench-able applicable approval agencies. protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model G5 series sprinklers are available as either Quick-response Model G5 series sprinklers can be installed without removing (QR)or Standard-response(SR)depending on the approval the wrench-able protective cap using the Model W3 wrench. agency and cover plate selected. Alternatively, Model G5 series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap Model G5 series sprinklers use Model G5 flat cover plates. Model during installation of the sprinkler.The use of any other wrench G5 QR Gasket and G5 SR Gasket cover plates are available to to installed Model G5 series sprinklers is not permitted and may limit air and dust movement through the ceiling. damage the sprinkler. Bulletin 034 Page 8 of 9 February 2021 Rellable www.reliablesprinkler.com Wrench Model FC Model W3 For use with Model G5 Series sprinklers For use with Model G5 Series sprinklers with without wrench-able cap installed wrench-able cap installed Fully insert the Model W3 wrench over the cap until it reaches Replace any sprinkler or cover plate which has been painted(other the bottom of the cup,or the Model FC wrench over the sprinkler than factory applied).Properly installed Model G5 cover plates will until the wrench engages the body. Do not wrench any other have an air gap that is required for proper operation, do not seal part of the sprinkler/cup assembly.The Model W3 and FC the gap or paint the cover plates. Model G5 series sprinklers have wrenches are designed to be turned with a standard 1/2"square holes in the cup that must remain unobstructed. drive.Tighten the sprinkler into the fitting after applying a PTFE Replace any sprinkler which has been damaged.A stock of spare based thread sealant to the sprinkler's threads. Recommended sprinklers should be maintained to allow quick re-placement installation torque is specified in Table J. of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Installation Torque rmm Recommended Installation Guarantee Sprinkler Threads Torque (min.—max.) For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, ft.lb N.m and conditions,visit www.reliablesprinkler.com. '/2"NPT or IS07-1 R1/2 8-18 11-24 %"NPT or IS07-1 R3/4 14-20 19-27 Patents Do not exceed the maximum recommended torque.Exceeding the Model G5 series sprinklers may be covered by one or more of the maximum recommended torque may cause leakage or impairment following patents: of the sprinkler. Use care when inserting or removing the wrench U.S. Patent 6,554,077, U.S. Patent 7,275,603, U.S. Patent from the sprinkler to avoid damage to the sprinkler. 8,776,903,U.S. Patent 9,248,327 Install the cover plate by hand,pushing and then turning the cover Ordering Information in the clockwise direction until it is tight against the ceiling. For Specify the following when ordering. Model G5 QR Gasket and Model G5 SR Gasket cover plates,the gasket should be attached to the flange of the cover plate skirt Sprinkler only. Do not glue the gasket in place or allow the gasket to overlap Model[G5-28][G5-42] [G5-56][G5-56 300] both the cover plate and the flange of the skirt. [G5-80][G5-80F] • Temperature Rating[165°F(74°C)][212°F(100°C)] Maintenance Threads[NPT or ISO 7-1] Reliable Model G5 series sprinkler should be inspected and the Cover Plate sprinkler system maintained in accordance with NFPA 25, as well Model[G5, G5 QR Gasket,G5 SR Gasket] as the requirements of any Authorities Having Jurisdiction. Finish(See Table 1) Prior to installation,sprinklers should remain in the original cartons Sprinkler Wrench and packaging until used. This will minimize the potential for Model W3 damage to sprinklers that could cause improper operation or non- Model FC operation. Do not clean sprinklers with soap and water,ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without 0 touching the sprinkler. rn rn rn z Bulletin 034 Reliable Page 9 of 9 February 2021 www.reliablesprinkler.com Bulletin 051 January 2020 W ® Model G5-56 Dry(SIN RA5114) K5.6 (80 metric) 11abi Concealed Dry Pendent Sprinkler N O ro UL Quick Response CD FM Standard Response ¢ 1/2" (13mm) Cover plate Adjustment Features 1. Rat cover plate with threaded attachment. 2. Cover plate available in chrome and white as Stan- dard Finishes, Also available in a wide variety of Special Application Finishes. " 3. Cover plates with gaskets are available to limit r� dust and air movement through the ceiling. 4. Available in Ordinary or Intermediate temperature rating. 5. Sprinkler available in lengths from 41/4 inches (108mm) to 48 inches (1219mm) in 1/4-inch (6.35mm)increments(see Fig. 1). Approvals & Listings Moe 5-56 Dry-Sprinkler 1. Listed by Underwriters Laboratories and Certified for Canada(cULus)as a Quick-response sprinkler for Light sealing washer to move out of the inlet orifice admitting water and Ordinary Hazard occupancies. UL Guide Number from the supply piping.The sprinkler uses a fast-response fus- VNIV,Sprinklers,Automatic and Open. ible element with an Ordinary, 165°F (740C), or Intermediate, 2. FM Approved as a Standard-response sprinkler. 212°F(100°C),temperature classification. Patents The Model G5-56 Dry sprinkler has a dropdown deflector The Model G5-56 Dry is covered by the following patents: design that allows the sprinkler to be recessed into the ceiling U.S. 5,775,431 and concealed by a flat cover plate.The cover plate assembly U.S. 5,967,240 threads into the sprinkler's cup and provides 1/2--inch(13mm)of cover adjustment. The cover plate assembly consists of a flat Application cover plate that is attached to the skirt using either 135°F(57°C) The Model G5-56 Dry is a cULus Listed Quick Response or 165°F (74°C) temperature rated solder. The 135°F (57°C) Concealed Dry Pendent sprinkler intended for use in accor- cover plates are for use with Ordinary temperature classifica- dance with NFPA 13.The Model G5-56 Dry sprinkler is cULus tion sprinklers and the 1650(74°C)cover plates are for use with Listed for use in Light and Ordinary Hazard occupancies. Intermediate temperature classification sprinklers. The Model G5-56 Dry is FM Approved as a Standard Re- The Model G5-56 Dry sprinkler is available in lengths rang- sponse Concealed Dry Pendent sprinkler intended for use in ing from 41/4 inches(108mm)to 48 inches(1219mm)in 1/4-inch accordance with FM Loss Prevention Data Sheet 2.0. (6.35mm) increments (see Fig, 1). The length of the sprinkler must be selected to provide the Exposed Minimum Barrel Product Description Length in a Heated Area required by Fig.2. The Reliable Model G5-56 Dry sprinkler is a Dry Pendent The Model G5-56 Dry sprinkler is available with 1-inch NPT sprinkler, where the sealing washer is located at the inlet end or ISO 7-1 R1 threaded inlet fittings.The standard inlet fitting in- of the sprinkler assembly The position of the sealing washer is cludes a long inlet designed to minimize the potential for water, controlled by a fusible element at the opposite end of the sprin- scale,and sediment to accumulate on the sprinkler inlet in wet- kler assembly.The sprinkler is installed with the fusible element and dry-pipe sprinkler systems. For wet-pipe sprinkler system at the ceiling of a protected space that may be subject to freez- applications where the standard inlet interferes with installation ing temperatures and the inlet orifice located in a heated area into existing plastic pipe fittings,an inlet fitting is available with a above the ceiling. Operation of the fusible element allows the short("PL")inlet.See Fig.3 for further information. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 k*; Technical Data: Temperature Rating Nominal Orifice Size: 1/2-inch (15mm) Max. Thread Size: 1-inch NPT per ANSI B2.1 or ISO 7-1 R1 Classification Sprinkler Cover Ambient Nominal K Factor: 5.6 (80 metric) Plate Temp. Maximum Working Pressure: 175 psi (12 bar) — 100% Ordinary 165°F(74°C) 135°F(57°C) 100°F(38°C) factory hydrostatically tested to 500 psi (34.5 bar) Intermediate 212°F(100°C) 165°F(74°C) 150°F(66°C) Sprinkler Installation Wrench: Model FC wrench Sprinkler Identification Number(SIN): RA5114 Materials: See Fig. 4 -— -�J Ls-l� -zJ r L- - System Fitting Inlet Threads 2-5/8" [67 mm] Dia. Hole in Ceiling "A" Dimension 2-5/16" Sprinkler [59 mm] Cup Assembly Nominal Position 1/2"[12 mm] of Cover Plate Total Cover Plate Adjustment Cover Plate 1/4"[6 mm] Assembly Cover Plate Adjustment ' Ceiling IL_ 1/4"[6 mm] Min.to 1/4"[6 mm] 051 FG01 B 5/8"[16 mm] Max. Cover Plate Adjustment Dropped Deflector to Ceiling Fig. 1 Note:The"A" dimension is based on a nominally gauged pipe thread "make-up"of 0.600"(15mm) per ANSI B2.1 [71/2 threads approximately]. "A"Dim. 41/n"to 48"(108mm to 1219mm)in Ya"(6.35mm)increments 2. Cover Plate Finishes sprinklers with the short inlet fitting shall not be used on dry- Standard Finishes �, ,;F, .��,,� pipe sprinkler systems. The Model G5-56 Dry sprinkler and White Paint :;; ;. the cover plate assembly are not intended for installation in Chrome corrosive environments, including, but not limited to, those Special Application with salt aerosols or chlorine. FinishesU1-1130OVV', Model G5-56 Dry sprinklers must be installed with the Ex- Off White Paint posed Minimum Barrel Length required by Fig. 2 located in Black Paint a Heated Area.Do NOT install the sprinkler in ceilings which Custom Color Paint—Specifyi'I have positive pressure in the space above. Raw Brass(Lacquered) Bright Brass The following steps must be followed for Finished Bronze Model FC installation: Satin Chrome Sprinkler Wrench 1. Cut a 25/-inch (67mm) diameter hole in the ceiling di- Stainless Steel Clad(2) rectly in-line with the outlet of the tee. 2. Apply pipe joint compound or Polytetrafluoroethylene (') Custom color paint is semigloss,unless specified otherwise. (PTFE)tape to the threads of the sprinkler's inlet fitting. (2) Stainless steel clad cover plates are Type 316 Stainless Steel on the finished 3. A protective cap is provided to protect the drop-down side and C102 Copper Alloy on the back side.Cover plates are not listed sprinkler deflector from damage which could occur Jur- or approved as corrosion resistant.Stainless steel clad cover plates are not ing construction before the cover plate is installed.The available perforated. cap is factory installed inside the sprinkler cup.Remove Optional Cover Plate with Gasket* the cap to install sprinkler,Step 4,then reinstall cap until the cover plate is installed. 4. Install the sprinkler in the tee using the Model FC wrench.The Model FC wrench has a socket drive which is inserted into the sprinkler's cup and around the body of the sprinkler prior to installation of the sprinkler. Do NOT wrench any of the part of the sprinkler/cup assem- bly. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to maximum installation torque is 22-30 Ib-ft Model G4/G5 Model G4/G5 SR Gasket (30—40 N-m). When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken OR Gasket Cover Plate to prevent damage to the sprinkler. Reinstall the protec- Cover Plate (FM Approved) tive cap following installation of the sprinkler, until the (cULus Listed) cover plate is installed. "Model G4/G5 OR Gasket and Model G4/G5 SR Gasket cover a. Alternatively,where access to the outer tube of the plates are sold as assembled units including both the cover sprinkler is available, the Model G5-56 Dry sprin- kler may be installed using a pipe wrench. The plate and gasket.Model G4/G5 OR Gasket and Model G4/G5 protective cap should not be removed to install SR Gasket cover plates and gaskets are not interchangeable. the sprinkler with a pipe wrench.The pipe wrench Installation Instructions shall only be permitted to interface with the steel Model G5-56 Dry sprinklers must only be installed in stan- outer tube portion of the sprinkler (Item #8 inFig. 4). Do NOT wrench any other portion of the dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) sprinkler/cup assembly.A pipe wrench can install pipe tees in the horizontal position,even at branch line ends. the sprinkler into the fitting with a large amount Model G5-56 Dry sprinklers shall not be installed into elbows of torque; consideration should be given to the or pipe couplings located on drop nipples to the sprinklers. need for future removal of the sprinklers because In all installations, including into CPVC piping,the dry sprin- the installation torque will have to be matched or kler shall be installed with protrusion into the fitting in accor- exceeded to remove the sprinkler. The recom- dance with the installation diagrams in this Bulletin. mended minimum to maximum installation torque Installation of the Model G5-56 Dry sprinkler is not recom- is 22-30 Ib-ft(30—40 N-m). mended in copper pipe systems, as this may reduce the 5. To install the cover plate,remove the protective cap and life expectancy of the sprinkler. Do not install Model G5-56 install the cover plate by hand turning the cover in the Dry sprinklers with the standard (long)inlet fitting into CPVC clockwise direction until it is tight against the ceiling. For adapter fittings or tees that have an internal obstruction(see Model G4/G5 OR Gasket and Model G4/G5 SR Gas- Fig. 3); this will damage the sprinkler, the fitting, or both. A ket cover plates, the gasket should be attached to the short inlet("PL")version of the Model G5-56 Dry sprinkler is flange of the cover plate skirt only. Do not glue the gas- available for use in existing installations with CPVC adapter ket in place or allow the gasket to overlap both the cover fittings or tees having an internal obstruction; Model G5-56 plate and the flange of the skirt. 3. MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM INSTALL 1 INCH NPT THREADED ENDOF DRY PENDENT SPRINKLER WET PIPE INTO THE 1 INCH NPT SIDE OUTLET EXPOSED BARREL OF A MALLEABLE IRON TEE FITTING AMBIENT AMBIENT TEMPERATURE I PER ANSI B 16.3(CLASS 150) TEMPERATURE -- -- ____ OR CAST IRON THREADED TEE FITTING OF PROTECTED 40°F/4°C 50°F/10°C 60°F/16°C -� ! r � PER ANSI 16.4(CLASS 125)ONLY. AREA*AT THE - ----�-ff{I DISCHARGE END EXPOSED MINIMUM BARREL LENGTH** 7�7 OF THE SPRINKLER (FACE OF TEE TO TOP OF CEILING) IN.(MM) IN. IN. IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 40°F(4°C) 0 0 0 0 0 �_ _ CAUSE CONDENSATION ON THE EXPOSED 30°F(-1°C) 0 0 0 DRY SPRINKLER,CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION,FOAM 20°F(-7°C) 4(100) 0 0 -- INSULATING TAPE OR EQUIVALENT. 10°F(-12°C) 8(200) 1(25) 0 0°F(-18°C) 12(300) 3(75) 0 MINIMUM (HEATED AREA) IF NECESSARY,SEAL THE CLEARANCE SPACE - EXPOSED AROUND THE SPRINKLER CUP TO AVOID 10°F(-23°C) 14(350) 4(100) 1(25) BARREL LEAKAGE OF AIR INTO THE PROTECTED -20°F(-29°C) 14(350) 6(150) 3(75) LENGTH AREA. -30°F(-34°C) 16(400) 8(200) 4(100) CLEARANCE DO NOT BLOCK VENT HOLES ON TOP OF CUP. A HOLE -40°F(_40°C) 18(450) 8(200) 4(100) DIMENSION -50°F(-46°C) 20(500) 10(250) 6(150) -60°F(-51°C) 20(500) 10(250) 6(150) INSIDE SURFACE OF * FOR AMBIFN1 TLMPLRATURES EXPOSED TO THE DISCHARGE INSULATION, WALL, OR ND 01 II-11 SPRINKLER IHAT OCCUR BETWEEN THE VALUES CEILING I1S11_D, USI TI-IL NLX1 COOLER TEMPERATURE. -* [HF MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE "A" DIMENSION. THE MINIMUM EXPOSED BARREL LLNCTH IS BASED ON A PROPERLY SEALED PENETRATION WITH COVER PLATE A MAXIMUM WIND VELOCI FY ON THE EXPOSED SPRINKLER OF CEILING 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL FII-1_P AVOID FREEZING OF THE WET PIPING WHERE HIGHER WIND VLIOCIIY IS EXPECTED. (PROTECTED AREA) 051FG02A - HIE MINIMUM EXPOSED BARREL LENGTH IS MEASURED 35/16"DIA. I ROM II-IE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSUI ATION, WALL, OR CEILING LEADING TO THE COLD SPACE, WHICHEVER IS CLOSEST TO THE FITTING. Fig.2 *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction;this will damage the sprinkler,the fitting, or both. Short inlet("PL")versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet("PL")should only be installed in CPVC fittings of wet-pipe systems. In all cases,verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal No Internal Obstruction Obstruction � I Female Female Pipe Pipe 00 Thread Thread CPVC Fitting with Internal Obstruction CPUC Fitting= No Internal Obstruction Shorter Longer Inlet Inlet ' Male Male Pipe Pipe Thread Thread -17; - -7L Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION COMDRYDET2 Fig.3 5. L Maintenance Ordering Information The Model G5-56 Dry should be inspected and the sprin- Specify: kler system maintained in accordance with NFPA 25. Do 1. Sprinkler: Model G5-56 Dry not clean sprinklers with soap and water, ammonia or any 2. Threads: [1-inch NPT-standard][ISO 7/1 R1 -optional] other cleaning fluids. Replace any sprinkler that has been 3. Inlet,Length: [Standard][Short ("PL")—for existing wet- painted (other than factory applied) or damaged in any pipe installations only] way. Concealed sprinklers cover plates can not be painted 4. Cover Plate Finish: [White][Chrome][Special Applica- in the field, after installation or have any other coating ap- tion—Specify] plied other than the factory finish. A stock of spare sprin- 5. Sprinkler/Cover Plate Temperature Rating: [Ordinary— klers should be maintained to allow quick replacement of 165°F sprinkler with 135°F cover plate][intermediate— damaged or operated sprinklers. Prior to installation,sprin- 212°F sprinkler with 165°F cover plate] kler should be maintained in the original cartons and pack- 6. Nominal Sprinkler Length (face of fitting to face of aging to minimize the potential for damage to sprinklers ceiling - "A" Dimension from Fig. 1): [Specify length — that would cause improper operation or non-operation. Lengths available from 41/a inches to 48 inches(108mm Engineering Specification to 1219mm) in 1/4-inch (6.35mm) increments] Model G5-56 Dry Pendent Concealed Sprinkler Dry pendent sprinklers shall be dry pendent concealed sprinklers with a flat cover plate. Sprinklers shall be cU- Lus Listed as Quick Response for Light and Ordinary Hazard applications as well as FM Approved as Standard Response. Sprinklers shall be available in lengths from 4'/4 inches (108mm) to 48 inches (1219mm) in 1/4-inch (6.35mm) increments based on face of fitting to finished ceiling distance. Sprinkler length shall be selected to pro- vide the Exposed Minimum Barrel Length based on the minimum design temperature in the protected area and the minimum temperature in the conditioned space where the barrel is located in accordance with the Manufactur- er's written installation instructions. Sprinklers shall have [1-inch NPT][ISO 7-1 R1] threaded inlet fittings with [stan- dard length inlets designed for use with wet- or dry-pipe sprinkler systems][short length inlets designed for use with wet-pipe sprinkler systems having pipe fittings with internal obstructions that prevent the insertion of standard length inlets]. Sprinklers shall have a PTFE coated beryllium nick- el Belleville spring washer inlet seal and brass alloy cap that prevent water entry from the sprinkler system piping into the sprinkler prior to actuation. Sprinklers shall have a fast-response fusible link that controls the movement of the inlet seal and cap through a mechanism consisting of link arms, a seat adapter, an orifice adapter, an inner tube, and a yoke. Sprinklers shall use a drop down deflector supported by tapered pins. Sprinklers shall have a galva- nized steel cup for threaded attachment of the flat cover plate assembly, Cover plate attachment shall provide up to '/z-inch (13mm) of adjustment. Sprinklers shall be [Ordi- nary temperature classification, 165°F (74°C), with 135°F temperature rated cover plates][Intermediate temperature classification, 212°F, with 165°F temperature rated cover plates]. Cover plates shall be[solid][perforated]with facto- ry applied [White][Chrome][Special Application—Specify] finish. Dry pendent concealed sprinklers shall be Reliable Model G5-56 Dry(SIN RA5114). 6. r MATERIAL SPECIFICATIONS ITEM# DESCRIPTION MATERIAL 1 BODY,MACH. DZR BRASS � �- �_ 2 DEFLECTOR COPPER ALLOY `-------- - = 8. 3 DEFL.SPLITTER BRASS ALLOY 4 DEFL.PIN STAINLESS STEEL 5 MEGA-INLET DZR BRASS 6 LINK ASSY. NICKEL/BERYLLIUM NICKEL 13,_ `\\ 7 LEVER COPPER ALLOY 8 OUTER TUBE GALVANIZED STEEL \\ t \\ :' 9 INNER TUBE BRASS ALLOY 10 FLIP DISK BRASS ALLOY 11 CAP BRASS ALLOY (T, 12 WASHER PTFE COATED BERYLLIUM NICKEL 13 SETSCREW STAINLESS OR ALLOY STEEL 14 LOAD SCREW STAINLESS STEEL 15 BOTTOM CUP GALVANIZED STEEL 16 TOP CUP GALVANIZED STEEL 17 ADJ.SEAT ADAPTER BRASS ALLOY 18 YOKE BRASS ALLOY / 19 CLOSURE YOKE BRASS ALLOY 20 ORIFICE ADAPTER BRASS ALLOY \ t 10` '-08 (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) 1416 .......... _— t_ � ✓l (J' 051 FG04 2 r!!yi 4il;.oi� Fig.4 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. Recycled ® (800)431-1588 Sales Offices 19 Paper Relle iabi (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.01/20 P/N 9999970480 L.c h Bulletin 014 August 2021 R Model F1 FR Series Quick Response o Glass Bulb Sprinklers Model F1 FR56 Sprinkler Types 7;> N Standard Spray Upright N Standard Spray Pendent '��`' `? Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall ? Model F1FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent ;R; _ -- Horizontal Sidewall . Model F1 FR56 Concealed Sprinkler Types Standard Spray Pendent al Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler Types Standard Spray Upright Vertical Sidewall Horizontal Sidewall Recessed Standard Spray Pendent Pendent/Fl/F2 Model F1 FR40 Sprinkler Types Standard Spray Pendent Model F1 FR42 F1 FR40 F1 FRXLH & F1 FR28 Recessed Sprinkler Types "f . . Standard Spray Pendent Model F1 FR56LL&F1 FR42LL Low Lead Sprinkler Recessed Concealed Recessed Types Horizontal Sidewall Pendent Pendent/FP Standard Spray Pendent with less than 0.25% Lead Con- tentM: Listing &Approvals i The following organizations provide Listings or Approvals for ` I Iter various Model F1 FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific XLH Upright XLH Pendent XLH Recessed listings and approvals applicable to each sprinkler. Pendent F1/F2 1. Underwriters Laboratories Inc.and Certified for Cana- Product Description da (cULus) in accordance with ANSI/UL199. , 2. FM Approvals (FM) Reliable Model F1 FR series sprinklers 3. Loss Prevention Certification Board (LPCB) are quick-response automatic sprinklers t . 4. VdS Schadenverhutung GmbH (vdS) with a glass bulb thermal element. Model �� .,_, F1 FR series sprinklers are Standard Spray 5. Underwriters Laboratories Inc. and Underwriters Lab- a'" oratories of Canada Certified for Health Effects to NSF/ sprinklers,with the exception of the Model ANSI Standard 61 Annex G (ULH) F1 FR56 Conventional sprinkler which is XLH Recessed 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- an Old-style/Conventional sprinkler. Pendent FP CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) The Model F1 FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated (EC) 7. (EC)Waterk certified. Certificate Number 23347. (WM) response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response UL Listing Category enables the Model F1 FR Series sprinklers to apply water to a Sprinklers,Automatic&Open(VNIV) fire faster than standard-response sprinklers of the same tem- Quick Response Sprinkler perature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule.This glass bulb is specially constructed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in Model F1 FR Series sprinklers must be installed with the Reli- both the liquid and vapor phases.The vapor phase can be seen able sprinkler installation wrench identified in the Design and as a small bubble.As heat is applied,the liquid expands,forcing Installation Information table in this Bulletin. Any other wrench the bubble smaller and smaller as the liquid pressure increases. may damage the sprinkler. A leak tight sprinkler joint can be Continued heating forces the liquid to push out against the bulb, obtained with a torque of 8 to 18 Ib-ft (11 to 24 N-m). Do not causing the glass to shatter,opening the waterway and allowing tighten sprinklers over the maximum recommended installation the deflector to distribute the discharging water. torque. Exceeding the maximum recommended installation Model F1 FR Series sprinklers provide a wide range of options torque may cause leakage or impairment of the sprinkler. where quick-response,glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal side- Model F1 FR Series Recessed sprinklers are to be installed wall, and vertical sidewall deflectors as shown in Fig. 1, Fig.2,or Fig.3,as applicable to the specific • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 model being installed.The Recessed Escutcheon Data table in metric), and 5.6 (80 metric) the Bulletin identifies the only recessed escutcheons that are • Flush, recessed, and concealed installations permitted to be used with each Model F1 FR Series Recessed See the Design and Installation Information table in this Bul- sprinkler.The use of any other recessed escutcheon will void all letin for information on the approvals and availability of specific approvals and negate all warranties. Model F1 FR series sprinkler configurations. Concealed Sprinklers Model F1 FR Recessed Pendent and Recessed Horizontal Model F1 FR Series Concealed Pendent sprinklers are to Sidewall sprinklers are required to be used with Reliable Model be installed as shown in Fig. 4 or Fig. 5, as applicable to the F1, F2, or FP recessed escutcheons. See the Recessed Es- selected cover plate. Model F1 FR56 Concealed Pendent and cutcheon Data table in this Bulletin for listing and approval infor- Model F1 FR56LL Concealed Pendent sprinklers have a facto- mation with each specific Model F1 FR series sprinkler. Model ry-installed Model CCP cup.A protective cap is installed at the F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are factory that should remain on the sprinkler until the sprinkler is a friction fit assembly allowing for 3/4-inch (19mm) and 1/2- installed and should then be reinstalled on the sprinkler until the inch(12.7mm)of adjustment,respectively. Model FP recessed cover plate is installed.The concealed sprinkler assemblies are escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) completed by the installation of a Model CCP push-on/thread- threaded adjustment. off cover plate assembly.The cover plate and sprinkler cup as- Model F1 FR56 Concealed Pendent and Model F1 FR56LL semblies are joined using a cover plate skirt with flexible tabs Concealed Pendent sprinklers are required to be used with for threaded engagement. A choice of two Model CCP cover Model CCP cover plates.A standard profile Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch plate is available that provides up to 1/2-inch(12.7mm)of cover (8mm) of cover adjustment. Do not install Model F1 FR Series plate adjustment. In addition, a low profile Model CCP cover Concealed Pendent sprinklers in ceilings which have positive plate is also available that provides up to 5/16-inch (8.Omm)of pressure in the space above. cover plate adjustment. See the Design and Installation Infor- Model F1 FR Series Concealed Pendent sprinklers require mation and Listed and Approved Temperature Ratings tables a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The in this Bulletin for further information on approved cover plate Model W4 wrench is used to engage the sprinkler wrenching sur- options. faces and to install the sprinkler in the fitting.Remove the protective Application cap to install the sprinkler,then reinstall the protective cap until the Model F1 FR Series sprinklers are intended for use in ac- cover plate is installed.When inserting or removing the wrench from cordance with NFPA 13, FM Property Loss Prevention Data the sprinkler/cup assembly,care should be taken to prevent dam- Sheets, and the requirements of the Authority Having Juris- age to the sprinkler.Do not wrench any other part of the sprinkler/ diction. Care must be exercised that the k-factor, tempera- cup assembly. Installation is completed by removing the protective ture rating, deflector style, and sprinkler type are in accor- cap from the sprinkler and pushing the cover plate onto the cup. dance with the requirements of the applicable design and Final adjustment is made by hand turning the cover plate until the installation.standards. In addition, Model F1 FR Series sprin- skirt flange makes full contact with the ceiling.Cover plate removal klers must be used in accordance with their listings and ap- requires turning the cover plate in the counter clockwise direction. provals, as well as the information provided in this Bulletin. After installation,inspect all sprinklers to ensure that there is a gap Installation between the cover plate and ceiling and that the four cup slots are Glass bulb sprinklers have orange bulb protectors or protec- open and free from any air flow impediment to the space above. tive caps to minimize bulb damage during shipping, handling Concealed cover plate/cup assemblies are listed only for use and installation. Reliable sprinkler installation wrenches are with specific sprinklers. The use of any concealed cover plate/ designed to install sprinklers with bulb protectors in place. Re- cup assembly other than the Reliable Model CCP with Model move the bulb protector at the time when the sprinkler system is F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed placed in service for fire protection.Removal of the bulb protec- Pendent sprinklers or the use of the Model CCP Concealed for before this time may leave the bulb vulnerable to damage. cover plate assembly on any sprinkler with which it is not spe- Remove bulb protectors by undoing the clasp by hand. Do not cifically listed my prevent good fire protection and will void all use tools to remove bulb protectors. guarantees,warranties,listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar)- 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414& RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal Orifice Sprinkler Listings K-factor Deflector/ Installation Approval Model Diameter Orientation Height Wrench SIN and Notes US Metric inches mm inches mm Approvals Pendent 2.25 57 W2 RA1411 cULus 2 F1 FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 W4 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 W4 RA1418 VdS Pendent 2.25 57 W2 RA1413 cULus 2 F1 FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 Upright 2.25 57 W2 RA14231 cULus 1,2 F1 FR42LL 4.2 60 7/16 10Pendent 2.25 57 W2 RAI 410 cULus,ULH Recessed Pendent 2.25 57 W4 RA1410 cULus,ULH F1 FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 (F1 FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 cULus,FM, Pendent 2.25 57 W2 RA1414 LPCB,VdS,EC, 1,2,3,4 WM cULus,FM, Recessed Pendent 2.25 57 W4 RA1414 LPCB,VdS,EC, 1,2,3,4 WM Fl FR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 W4 RA1414 cULu VdS,EC, 5,6 WM cULus,FM, Upright 2.25 57 W2 RA1425 LPCB,VdS, EC, 1,2,3,4 WM "Conventional 2 25 57 W2 RA1475 LPCB,VdS,EC, 4 (Pendent or Upright)" WM Pendent 2.25 57 W2 RA1415 cULus, ULH 1 FIFR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 W4 RA1415 cULus, ULH Concealed Pendent 2.25 57 W4 RA1415 cULus,ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus,FM 1,2,3,7 F1 FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 W4 RA1435 cULus,FM 8 Sidewall FlFR56 5.6 80 1/2 15 Vertical Sidewall(Pen- 2 25 57 W2 RA1485 cULus,FM, 1,2,3,9 dent or Upright) LPCB (')cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3)Available with FM approved Polyester coating in black or white. (4)Available with LPCB and VdS approved Polyester coating. (5)VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprinklers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (6)Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates,available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. (')cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches(102mm to 305mm).FM Approval of the F1 FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (8)cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (')The F1 FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies.LPCB approval of the F1 FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector/ 100°F(38°C)Max.Ambient 150T(65°C)Max.Ambient 225T(107°C)Max. Model OrientationQ Tem . Tem Ambient Temp. 135o F(57 C) 155-F(68-C) 175-F(79-C) 200 F(93o C) 286*17(141 C)Temp. Temp.Rating Temp.Rating Temp.Rating Temp.Ratin Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS Pendent cULus F1FR42 Recessed Pendent cULus Upright cULus F1FR42LL Pendent cULus,ULH Recessed Pendent cULus,ULH Pendent cULus F1 FRXLH Recessed Pendent cULus Upright cULus Pendent cULus,FM,LPCB,VdS,EC,WM Recessed Pendent cULus,FM,LPCB,VdS,EC,WM 171 FR56 Concealed Pendent` cULus,WM cULusNVMS,EC, cULus,WM Upright cULus,FM,LPCB,VdS, EC,WM "Conventional LPCB,VdS,EC,WM Pendent or Upright)" Pendent cULus, ULH F1FR56LL Recessed Pendent cULus,ULH Concealed Pendent' cULus,ULH Horizontal Sidewall cULus,FM F1 FR56 Recessed Horizontal cULus, FM Sidewall F1 FR56 Vertical Sidewall(Pen- cULus,FM,LPCB dent or Upright) Model F1 FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For In- termediate Temperature Classification sprinklers use a 1657(74°C)temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model F1 Model F2 Model FP Model Orientation (Fig.1 &3) (Fig.1 &3) (Fig.2) SIN 3/4-inch(19mm) 1/2-inch(12.7mm) 1/2-inch(12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 FlFR42LL Recessed Pendent cULus,ULH cULus,ULH cULus,ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus,LPCB,VdS, cULus,FM,LPCB, cULus,VdS,EC,WM RA1414 EC,WM VdS,EC,WM F1FR56LL Recessed Pendent cULus,ULH cULus,ULH cULus,ULH RA1415 F1 FR56 Recessed Horizontal Sidewall cULus cULus,FM cULus RA1435 4. 2 1/4-HOLE DIA. [57.2mm] 1 15/16"DIA [49.2mm] / —_— 1"X 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS FACE OF FITTING \ / TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1'[25.4mm] L J AT MINIMUM RECESS = 3/8'[9.5mm] Fl ESCUTCHEON LYS/11L// F2 ESCUTCHEON 3/4'TI9mm] AT MAXIMUM RECESS = 3/4'T19mm] ADJUSTMENT AT MINIMUM RECESS = 3/8'T9.5mm] F2 ESCUTCHEON 1/2'T12.7mm] ADJUSTMENT F1 ESCUTCHEON AT MAX/MUM RECESS = 7/8'[22.2mmJ [3.2mmJ AT MINIMUM RECESS = 1-5/8'[41.3mmJ F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'[28.6mm] AT MINIMUM RECESS = 1-5/8"[41.3mm] 2 27/32"DIA. [72.2mmJ Fig. 1 Model F1 FR56,F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon I I 1" X 1/2" REDUCER -----I----- 2 5/8" 01A. [66.7mm] HOLE IN CEILING 1 1 2 5/16" DIA. [58.7mm] CUP L J CEILING FACE OF FITTING 03svu TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = 1-1/2'T38mm] AT MINIMUM RECESS = 1'[25.4mm] � I AT MAXIMUM RECESS = 9/16'[14.3mm] %2'T 12.7mm] AT MINIMUM RECESS = 1'[25.4mm] ADJUSTMENT 3 1/4 DIA. [82.6mm] Fig.2 Model F1 FR56,F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1'[25.4mm] AT MINIMUM RECESS = 3/8'T9.5mm] F1 ESCUTCHEON F2 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8'T34.9mm] AT MAXIMUM RECESS = 3/4'T 19mm] AT MINIMUM RECESS = 2-1/16'[52.4mm] AT MINIMUM RECESS = 3/8'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'T41.3mmJ 2 114" HOLE DIA. 1/8„ AT MINIMUM RECESS = 2-1/16'T52.4mm] [57.2mm] (3.2mm] 1" X 1/2" REDUCER nl I —I I IIIIIII i 4"-12" 1 15/16" DIA. J lilll I ---- [101.6mm-304.8mm] (49.2mmJ i 2 27/32" DIA. CEILING TO mn [72.2mmJ DEFLECTOR uni TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. F1 ESCUTCHEON 3/4'(19mm] ADJUSTMENT F2 ESCUTCHEON 1/2'T 12.7mmJ ADJUSTMENT olsmac RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MMJ CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW — — — --------+-------- ------ 2 518" DIA. 2 5/16" DIA — ;' �; HOLE /N CEILING L_ _J CUP ®� d� 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING T/ DIMENSION CE/LING I 1/2" MAX. --- — 15/16" COVER ADJUSTMENT j COVER PLATE — ASSEMBLY /J 5176" DIA. SPRINKLER CONCEALED, 1/2" ADJUSTMENT 017FG°I^ Fig.4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch(12.7mm)adjustment-Model CCP cover plate 6. I" x 1/2" REDUCING TEE OR ELBOW ——— --------+-------- ------ 2 5/8" DIA. 2 5/16" DIA I HOLE IN CEILING CUP � ®a vu 1 1/2" MAX. FACE OF FITTING " +TO FACE OF CEILING _ r J� I ; �_' DIMENSION :tea_' CEILING "' "' 5116" MAX. 3/4" COVER ADJUSTMENT J� j COVER PLATE— ASSEMBLY 3 5116" DIA. SPRINKLER / CONCEALED, 5/16" ADJUSTMENT 017FG02A Fig. 5-Model H FHbb/Fl I­RbbLL Concea e en ent sprinkler with ow profile - inch (8.Omm) adjustment-Model CCP cover plate Maintenance Material Data The Model F1 FR Series sprinklers should be inspected and Frame: DZR Brass,QM Brass,or Low Lead Brass the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any Deflector: CDA Alloy 220,260,or 510 other cleaning fluids.Remove dust by using a soft brush or gen- Load ScrewlPintle: CDA Alloy 360 or 544 tle vacuuming. Replace any sprinkler which has been painted Cup: CDA Alloy 651 or 693 (other than factory applied)or damaged in any way.A stock of Washer: Nickel Alloy 440 or 360,coated with PTFE spare sprinklers should be maintained to allow quick replace- Adhesive Tape ment of damaged or operated sprinklers. Bulb: Glass Finishes (1) Standard Finishes Ordering Information Sprinkler Escutcheon Cover later') g Bronze Brass Chrome Specify: Chrome Plated Chrome Plated White 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] Polyester Coated(4)(5)(5) White Painted Special A lication Finishes [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Escutcheon Cover plateM 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Electroless Nickel Electroless Nickel Pendent][Upright][Conventional][Horizontal Sidewall] PTFE(7) PTFE Bright Brass [Recessed Horizontal Sidewall][Vertical Sidewall] Bright Brass(3) Bright Brass Black Platin Black Paint(2)(6) Black Paint Off White 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Off White(2)(6) Off White Satin Chrome 4. Sprinkler Temperature Rating: [135'F (57'C)][155'F Chrome Dull Chrome Dull (68°C)][175°F (79°C)][200°F (93°C)][286°F(141-C)] (1)Other finishes and colors are available on special order.Consult the fac- 5. Sprinkler Finish tory for details. Custom color painted sprinklers may not retain their UL 6. Escutcheon Model: [F1][F2][FP] Corrosion resistance listing.Coverplate custom paint is semi-gloss,unless specified otherwise. 7. Escutcheon Finish (where applicable) (2) cULus Listed only. 8. Cover plate Model: [standard profile CCP 1/2-inch (3) 200°F(93°C)maximum. (12.7mm) adjustment][low profile CCP 5/16-inch (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW),RA1485(VSW),RA1425(Upright),RA1414(Pendent)and RA1415 (g,Omm) adjustment] (Pendent)in standard black or white.Corrosion resistance in other polyester 9. Cover plate Temperature Rating: [1357 (57°C) for use colors is available upon request. with Ordinary Temperature sprinklers][165'F (74°C) for (5) FM Approvals finish as"Polyester coated"applies to SIN Number use with Intermediate Temperature sprinklers] RA1414,RA1435 and RA1425 in standard black or white. (6)LPCB and VdS Approved finish applies only to RA1425,RA1414,RA1418 (VdS) 10. Cover plate Finish and RA1475. (')cULus listed Corrosion Resistant Note:When Model F1 FR Series Recessed sprinklers are ordered,the sprin- klers and escutcheons are packaged separately. 7. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many pre- cision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fre Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. AlIQ Recycled (800)431-1588 Sales Offices Paper Reliabid (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.08/21 P/N 9999970300 •i Bulletin 034 February 2021 ® Model G5 Series Sprinklers Standard Spray, Flat Concealed Pendent Imlabi Available with Gasketed Cover Plate Features • Standard Coverage,Concealed Pendent(K2.8,4.2,5.6,&8.0 AWN [40,60,80,&115 metric]) - • Flat concealed cover plate available in a variety of finishes. • Available with Stainless Steel Clad cover plate(see Table 1). • 3/4-inch (19 mm)cover plate adjustment. • Cover plate available with optional gasket. Model G5 Cover Plate Model G5 Cover Plate Product Description with QR Gasket Model G5 series sprinklers are standard coverage,flat plate concealed sprinklers designed for installation in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets.All Model G5 series sprinklers use a fusible-link operating element. The sprinklers are offered with a standard Model G5 cover plate, a Model G5 cover plate with a quick-response(QR)gasket,or a Model G5 cover plate with a standard-response(SR)gasket.Model G5 sprinklers with a gasketed cover plate are intended for use in Model G5 Cover Plate dust free environments such as clean rooms. with SR Gasket Model G5 sprinklers must only be used with the Model G5 cover Note:Gasket material is silicone rubber,available in white only. plate listed or approved with the sprinkler.Table A provides a summary of available Model G5 series sprinklers,along with Listing and Approval information for each sprinkler and cover plate combination. Model G5 Series Sprinkler Summary K-Factor Listings Max.Working Sprinkler Sprinkler gpm/psi112 Cover Plate and Sensitivity Pressure Identification Model (L/min/bar'12) Model Approvals psi(bar) Number(SIN) G5 cULus QR G5-28 2.8 FM SR(40) G5 QR Gasket cULus QR 175(12) RA3411 G5 SR Gasket cULus, FM SR G5 G5-42 (60) G5 QR Gasket cULus QR 175(12) RA3413 G5 SR Gasket cULus SR G5 cULus QR 250(17) FM, LPCB,VdS, CE SR 175(12) G5-56 (80) G5 QR Gasket cULus QR 250(17) RA3415 G5 SR Gasket cULus SR 250(17) FM SR 175(12) G5 G5-56 300 (80) G5 QR Gasket cULus QR 300(21) RA4014 G5 SR Gasket cULus SR G5 G5-80 (810) G5 QR Gasket cULus QR 175(12) RA3412 G5 SR Gasket cULus SR G5-80F (8.0) G5 SR Gasket FM SR 175(12) RA3417 www.reliablesprinkler.com 4 ' Model G5-28 Standard Coverage,Concealed Pendent Sprinkler SIN RA341, Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) Threads:1/2"NPT or ISO 7-1 R/z 212°F(100°C) < s.. Nominal K-Factor:2.8(40 metric) Sensitivity a Max.Working Pressure:175 psi(12 bar) (See Table B) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 OR Gasket(cULus only) Levers:Bronze Alloy Model G5 SR Gasket ; ` Yoke:Brass Alloy Sealing washer:Nickel with PTFE Cover Plate Finishes Load Screw:Bronze Alloy (See Table I) Pte, Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model W3 " a• Deflector:Bronze Alloy Model FC = Cup:Steel Listings and Approvals cULus Listed(Light Hazard only) FM Approved Model G5-28 Sprinkler Components and Dimensions 2-5/16" ---- (58 mm) Dia. Threads Body Cup Ceiling Tower """435116- Fusible Link I 3/4"(19 mm)Max. Deflector(retracted) �.; �; Cover Plate Adjustment 3/16"(5 mm) Pin(extended)—/ Deflector(extended)--- ^s Model G4/G5 Cover Plate (84 mm)'Dia. Ceiling Model G5-28 Sprinkler Sensitivity F1. Cover Plate Model Listing or Approval Agency cULus FM G5 QR SR 7 G5 QR Gasket QR G5 SR Gasket SR SR QR:Quick-response SR:Standard-response Bulletin 034 Page 2 of 9 February 2021 Reliable www.reliablesprinkler.com Model G5-42 Standard . Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) Threads:1/2'NPT or ISO 7-1 131/2 212°F(100°C) S Nominal K-Factor:4.2(60 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) (See Table C) ~ $m Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 OR Gasket Levers:Bronze Alloy Model G5 SR Gasket Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE (See Table 1) Load Screw:Bronze Alloy Towers:Copper Alloy Sprinkler Wrench ' e` Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light Hazard only) Model G5-42 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower Fusible Link I I 3/4"(19 mm)Max. Deflector(retracted) �. I. Cover Plate Adjustment 3/16"(5 mm) ....... Pin(extended) 11 ....... Deflector(extended) Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-42 Sensitivity Listing or Approval Agency Cover Plate Model cULus 77 G5 OR G5 OR Gasket OR G5 SR Gasket SR QR: Quick-response SR:Standard-response Bulletin 034 www.reliablesprinkler.com 3 of 9 February 2021 www.reliablesprinkler.com I � Model G5-56 Standard Coverage,Concealed Pendent Sprinkler SIN RA3415 Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) Threads:112"NPT or ISO 7-1 131/2 212°F(100°C)(cULus,FM,LPCB,CE only) Nominal K-Factor:5.6(80 metric) Sensitivity Max.Working Pressure: See Table D 175 psi(12 bar) ( ) Cover Plates 250 psi(17 bar)(cULus only) ; Model G5 Material Specifications Model G5 OR Gasket(cULus only) ' Fusible Link:Beryllium Nickel Model G5 SR Gasket(cULus and FM only) a. Sprinkler Body:Brass Alloy Cover Plate Finishes Levers:Bronze Alloy �I%:., •* Yoke:Brass Alloy (See Table I) Sealing washer:Nickel with PTFE Sprinkler Wrench Load Screw:Bronze Alloy Model W3 Towers:Copper Alloy Model FC Pins:Stainless Steel Listings and Approvals Deflector:Bronze Alloy cULus Listed(Light&Ordinary Hazard only) Cup:Steel Steel FM Approved LPCB Approved VdS Approved[165°F(74°C)only] CE Listed(2831-CPR-S2062) Model G5-56 Sprinkler Components and Dimensions �. r 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower Fusible Link 3/4"(19 mm)Max. - Deflector(retracted) I Cover Plate Adjustment 3/16"(5 mm) Pin(extended)------ Deflector extended)—/Deflector(extended) Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-56 Sensitivity Listing or Approval Agency Cover Plate Model cULus FM LPCB,VdS,CE G5 OR SR SR G5 OR Gasket OR - G5 SR Gasket SR SR QR:Quick-response SR:Standard-response Bulletin 034 Reliable Page 4 of 9 February 2021 www.reliablesprinkler.com 4 Modelior Coverage,Concealed SIN RA40V Technical Specifications Sprinkler Temperature Ratings , ,, Style:Flat Concealed Pendent 165-F(74°C) Threads:112"NPT or ISO 7-1 R1/2 212°F(100°C) Nominal K-Factor:5.6(80 metric) Sensitivity Max.Working Pressure:300 psi(21 bar) (See Table E) ; Material Specifications Cover Plates t Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 QR Gasket Levers:Bronze Alloy Model G5 SR Gasket t ..•;,_ Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE See Table 1 �=0 m - Load Screw:Bronze Alloy ( ) ° Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light&Ordinary Hazard only) Model G5-56 300 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower 3/16"(5 mm) Fusible Link I I 3/4"(19 mm)Max. ' -- Deflector(retracted) �. Cover Plate Adjustment Pin(extended) I I Deflector extended -3,..�z--- •' } Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-56 300 Sensitivity mag- Listing or Approval Agency Cover Plate Model cULus G5 QR G5 QR Gasket QR G5 SR Gasket SR QR: Quick-response SR:Standard-response Bulletin 034 Page 5 of 9 February 2021 Reliable www.reliablesprinkler.com J Model i Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) , - Threads:3/4"NPT or ISO 7-1 R3/4 212°F(100°C) 1` Nominal K-Factor:8.0(115 metric) Sensitivity - Max.Working Pressure: 175 psi(12 bar) (See Table F) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 QR Gasket ` Levers:Bronze Alloy Model G5 SR Gasket Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE (See Table 1) M T� Load Screw:Bronze Alloy ' Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light&Ordinary Hazard only) Model G5-80 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower Fusible Link 3/4"(19 mm)Max. 3/16"(5 mm) Deflector(retracted) ;; Cover Plate Adjustment Pin(extended) i Deflector(extended) Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-80 Sensitivity Listing or Approval Agency Cover Plate Model cULus G5 QR G5 QR Gasket QR G5 SR Gasket SR QR: Quick-response SR:Standard-response Bulletin 034 Reliable Page 6 of 9 February 2021 www.reliablesprinkler.com Model :0 .. Sprinkler Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) Threads:3/4"NPT or ISO 7-1 R3/. 212°F(100°C) Nominal K-Factor:8.0(115 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) Standard Response Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 SR Gasket Levers:Bronze Alloy Cover Plate Finishes Yoke:Brass Alloy (See Table 1) Sealing washer:Nickel with PTFE Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model W3 Pins:Stainless Steel Model FC Deflector:Stainless Steel Listings and Approvals &' Cup:Steel FM Approved Model G5-80F Sprinkler Components and Dimensions 2-5/16" (58 mm)-� Dia. Threads Body Cup Ceiling Tower ,����„ Fusible Link 3/4"(19 mm)Max. - Deflector(retracted) �. Cover Plate Adjustment 3/16"(5 mm) Pin(extended) Deflector(extended) Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-80F Sensitivity Listing or Approval Agency Cover Plate Model FM G5 SR GSSR Gasket SR SR:Standard-response Bulletin 034 www.reliablesprinkler.com 7 of 9 February 2021 www.reliablesprinkler.com t. ti Installation Dimensions and Cover Plate Information Min.to Max. Min.to Max. Cover Plate Recommended Cover Plate Face of Fitting Dropped Cover Plate Cover Plate Diameter Hole Diameter in Adjustment to Deflector Temperature Ceiling Distance Rating Model Inch Inch Inch Ceiling�'> below Ceiling °F (mm) (mm) (mm) Inch(mm) Inch (°C) mm G5 3-5/16 (84) 135OF(3) 3-11/16 (57°C) G5 QR Gasket(') (94) 2-5/8 314 1-t/2 to 2-t/4 1/4 to 1 (67) (19) (38 to 57) (6 to 25) or G5 SR Gasket(2) 4 165°F(4) (101 mm) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on nominal thread make up.Verify dimensions based on fitting and thread sealing method prior to installation.A 1/2"x 1/2"brass nipple extension(Reliable P/N 6999991900)is available to assist with replacement of Reliable Model G4A sprinklers. 2. Model G5 QR Gasket and Model G5 SR Gasket cover plates are sold as assembled units including both the cover plate and gasket.Model G5 QR Gasket and Model G5 SR Gasket cover plates and gaskets are not interchangeable. 3. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). 4. For use with 212°F(100°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F(66°C). Cover Plate Finishes(l)i2> _ Standard Finishes Special Application Finishes Listing &Approval Agencies White Paint Off-White Paint Individual Model G5 series sprinkler may be listed or approved by ChromeN Black Paint the following agencies:, Custom Color Paint(Specify)(3) Underwriters Laboratories,Inc.and UL Canada(cULus) Raw Brass(Lacquered) ListingCategoSprinklers,Automatic and Oen Bright Brass(4) GuidNumber:bN V p Finished Bronze(4) FM Approvals FM Black Plated(1) Loss Prevention Certification BoardLPCB Satin Chrome(4> � ( ) Stainless Steele(1) � VdS Schadenverhutung GmbH (VdS) • EC-Certificate of Conformity 0832-CPD-2062(CE) Notes: See Table A and the individual sprinkler data sheets in this Bulletin 1. Paint or any other coating applied over the factory finish will void all for listings and approvals applicable to each sprinkler. approvals and warranties. 2. Cover plates do not carry corrosion resistant listings or approvals. 3. Custom color paint is semi-gloss unless specified otherwise. 4. Not listed for use with QR sealing gasket. Installation 5. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C1 02 Copper Alloy on the back side. Model G5 series sprinklers are intended to be installed in accordance with NFPA 13, FM Global Property Loss Prevention Application Data Sheets,and the requirements of applicable authorities having jurisdiction. Model G5 series sprinklers must not be Model G5 series sprinklers are standard coverage,flat plate installed in ceilings with positive pressure in the space above. concealed pendent sprinklers.The sprinklers are intended for Ensure that the 4 slots in the cup are open and unobstructed use in accordance with NFPA 13 and FM Global Property Loss following installation. Prevention Data Sheets,as well as the requirements of the Model G5 series sprinklers are shipped with a wrench-able applicable approval agencies. protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model G5 series sprinklers are available as either Quick-response Model G5 series sprinklers can be installed without removing (QR)or Standard-response(SR)depending on the approval the wrench-able protective cap using the Model W3 wrench. agency and cover plate selected. Alternatively, Model G5 series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap Model G5 series sprinklers use Model G5 flat cover plates. Model during installation of the sprinkler.The use of any other wrench G5 QR Gasket and G5 SR Gasket cover plates are available to to installed Model G5 series sprinklers is not permitted and may limit air and dust movement through the ceiling. damage the sprinkler. Bulletin 034 Reliable Page 8 of 9 February 2021 www.reliablesprinkler.com S Wrench .�,,s .•s Amu Model FC �- Model W3 For use with Model G5 Series sprinklers For use with Model G5 Series sprinklers with without wrench-able cap installed wrench-able cap installed Fully insert the Model W3 wrench over the cap until it reaches Replace any sprinkler or cover plate which has been painted(other the bottom of the cup,or the Model FC wrench over the sprinkler than factory applied).Properly installed Model G5 cover plates will until the wrench engages the body. Do not wrench any other have an air gap that is required for proper operation, do not seal part of the sprinkler/cup assembly.The Model W3 and FC the gap or paint the cover plates. Model G5 series sprinklers have wrenches are designed to be turned with a standard 1/2"square holes in the cup that must remain unobstructed. drive.Tighten the sprinkler into the fitting after applying a PTFE Replace any sprinkler which has been damaged.A stock of spare based thread sealant to the sprinkler's threads. Recommended sprinklers should be maintained to allow quick re-placement installation torque is specified in Table J. of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Installation Torque Recommended Installation Guarantee Sprinkler Threads Torque (min.—max.) For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, ft.lb N.m and conditions,visit www.reliablesprinkler.com. '/2"NPT or IS07-1 R1/2 8-18 11-24 '/4"NPT or IS07-1133/4 14-20 19-27 Patents Do not exceed the maximum recommended torque.Exceeding the Model G5 series sprinklers may be covered by one or more of the maximum recommended torque may cause leakage or impairment following patents: of the sprinkler. Use care when inserting or removing the wrench U.S. Patent 6,554,077, U.S. Patent 7,275,603, U.S. Patent from the sprinkler to avoid damage to the sprinkler. 8,776,903,U.S. Patent 9,248,327 Install the cover plate by hand,pushing and then turning the cover Ordering Information in the clockwise direction until it is tight against the ceiling. For Specify the following when ordering. Model G5 QR Gasket and Model G5 SR Gasket cover plates, the gasket should be attached to the flange of the cover plate skirt Sprinkler only. Do not glue the gasket in place or allow the gasket to overlap Model[G5-28][G5-42][G5-56][G5-56 300] both the cover plate and the flange of the skirt. [G5-80][G5-80F] • Temperature Rating[165°F(74°C)] [2127(100°C)] Maintenance Threads[NPT or ISO 7-1] Reliable Model G5 series sprinkler should be inspected and the Cover Plate sprinkler system maintained in accordance with NFPA 25, as well Model[G5,G5 QR Gasket,G5 SR Gasket] as the requirements of any Authorities Having Jurisdiction. Finish(See Table 1) Prior to installation,sprinklers should remain in the original cartons Sprinkler Wrench and packaging until used. This will minimize the potential for Model W3 damage to sprinklers that could cause improper operation or non- Model FC operation. Do not clean sprinklers with soap and water,ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without o touching the sprinkler. rn rn z Bulletin 034 Reliable Page 9 of 9 February 2021 www.reliablesprinkler.com r Bulletin 051 January 2020 R Model G5-56 Dry(SIN RA5114) K5.6 (80 metric) CD bi Concealed Dry Pendent Sprinkler N 0 UL Quick Response FM Standard Response m 1/2" (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Cover plate available in chrome and white as Stan- dard Finishes. Also available in a wide variety of Special °^ Application Finishes. 3. Cover plates with gaskets are available to limit dust and air movement through the ceiling. 4. Available in Ordinary or Intermediate temperature rating. 5. Sprinkler available in lengths from 41/4 inches (108mm) to 48 inches (1219mm) in 1/4-inch (6.35mm)increments(see Fig. 1). Approvals & Listings 1. Listed by Underwriters Laboratories and Certified for ode 5-56 r Sprinkler Canada(cULus)as a Quick-response sprinkler for Light sealing washer to move out of the inlet orifice admitting water and Ordinary Hazard occupancies. UL Guide Number from the supply piping.The sprinkler uses a fast-response fus- VNIV,Sprinklers,Automatic and Open. ible element with an Ordinary, 165°F (740C), or Intermediate, 2. FM Approved as a Standard-response sprinkler. 212°F(1000C),temperature classification. Patents The Model G5-56 Dry sprinkler has a dropdown deflector The Model G5-56 Dry is covered by the following patents: design that allows the sprinkler to be recessed into the ceiling U.S. 5,775,431 and concealed by a flat cover plate.The cover plate assembly U.S. 5,967,240 threads into the sprinkler's cup and provides 1/2-inch(13mm)of cover adjustment. The cover plate assembly consists of a flat Application cover plate that is attached to the skirt using either 135°F(57°C) The Model G5-56 Dry is a cULus Listed Quick Response or 165°F (74°C) temperature rated solder. The 135°F (57°C) Concealed Dry Pendent sprinkler intended for use in accor- cover plates are for use with Ordinary temperature classifica- dance with NFPA 13.The Model G5-56 Dry sprinkler is cULus tion sprinklers and the 165'(74'C)cover plates are for use with Listed for use in Light and Ordinary Hazard occupancies. Intermediate temperature classification sprinklers. The Model G5-56 Dry is FM Approved as a Standard Re- The Model G5-56 Dry sprinkler is available in lengths rang- sponse Concealed Dry Pendent sprinkler intended for use in ing from 4'/4 inches(108mm)to 48 inches(1219mm)in'/4-inch accordance with FM Loss Prevention Data Sheet 2.0. (6.35mm) increments (see Fig. 1), The length of the sprinkler must be selected to provide the Exposed Minimum Barrel Product Description Length in a Heated Area required by Fig.2. The Reliable Model G5-56 Dry sprinkler is a Dry Pendent The Model G5-56 Dry sprinkler is available with 1-inch NPT sprinkler, where the sealing washer is located at the inlet end or ISO 7-1 R1 threaded inlet fittings.The standard inlet fitting in- of the sprinkler assembly The position of the sealing washer is cludes a long inlet designed to minimize the potential for water, controlled by a fusible element at the opposite end of the sprin- scale,and sediment to accumulate on the sprinkler inlet in wet- kler assembly.The sprinkler is installed with the fusible element and dry-pipe sprinkler systems. For wet-pipe sprinkler system at the ceiling of a protected space that may be subject to freez- applications where the standard inlet interferes with installation ing temperatures and the inlet orifice located in a heated area into existing plastic pipe fittings,an inlet fitting is available with a above the ceiling. Operation of the fusible element allows the short("PL")inlet.See Fig.3 for further information. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data: Temperature Rating Nominal Orifice Size: 1/2-inch (15mm) Max. Thread Size: 1-inch NPT per ANSI B2.1 or ISO 7-1 R1 Classification Sprinkler Cover PlateAmbient Nominal K Factor: 5.6 (80 metric) Temp. Maximum Working Pressure: 175 psi (12 bar) - 100% Ordinary 165°F(74°C) 135°F(57"C) 100°F(38°C) factory hydrostatically tested to 500 psi (34.5 bar) Intermediate 212°F(100°C) 165°F(74°C) 150°F(66°C) Sprinkler Installation Wrench: Model FC wrench Sprinkler Identification Number(SIN): RA5114 Materials: See Fig. 4 � ---------- 4 -i�7--- r� i I I I - �- --i— - - —+— — - u -- t-- Ls—l1 r l �- - System Fitting Inlet Threads 2-5/8" [67 mm] Dia. - 77 Hole in Ceiling "A" Dimension 2-5/16" Sprinkler [59 mm] Cup Assembly Nominal Position 1/2" [12 mm] of Cover Plate Total Cover Plate Adjustment Cover Plate 1/4"[6 mm] Assembly Cover Plate Adjustment ' 1 Ceiling ,— i�- 1/4"[6 mm] Min.to 1/4" [6 mm] 051 FG01 B 5/8"[16 mm] Max. J Cover Plate Adjustment Dropped Deflector to Ceiling Fig. 1 Note:The"A" dimension is based on a nominally gauged pipe thread "make-up"of 0.600" (15mm) per ANSI B2.1 [71/2 threads approximately]. "A"Dim. 41/4"to 48"(108mm to 1219mm)in'/4"(6.35mm)increments 2. Y Cover Plate Finishes sprinklers with the short inlet fitting shall not be used on dry- , , Standard Finishes �,_�_ ��.,° pipe sprinkler systems. The Model G5-56 Dry sprinkler and White Paint °;: the cover plate assembly are not intended for installation in Chrome corrosive environments, including, but not limited to, those Special Application with salt aerosols or chlorine. Finishes Model G5-56 Dry sprinklers must be installed with the Ex- Off White Paint posed Minimum Barrel Length required by Fig. 2 located in Black Paint 3=1 a Heated Area.Do NOT install the sprinkler in ceilings which Custom Color Paint—SpecV') have positive pressure in the space above. Raw Brass(Lacquered) Bright Brass The following steps must be followed for Finished Bronze Model FC installation: Satin Chrome Sprinkler Wrench 1. Cut a 25/8-inch (67mm) diameter hole in the ceiling di- Stainless Steel Clad(2) rectly in-line with the outlet of the tee. 2. Apply pipe joint compound or Polytetrafluoroethylene (') Custom color paint is semi-gloss,unless specified otherwise. (PTFE)tape to the threads of the sprinkler's inlet fitting. (2) Stainless steel clad cover plates are Type 316 Stainless Steel on the finished 3. A protective cap is provided to protect the drop-down side and C102 Copper Alloy on the back side.Cover plates are not listed sprinkler deflector from damage which could occur Jur- or approved as corrosion resistant.Stainless steel clad cover plates are not ing construction before the cover plate is installed.The available perforated. cap is factory installed inside the sprinkler cup.Remove Optional Cover Plate with Gasket* the cap to install sprinkler,Step 4,then reinstall cap until the cover plate is installed. 4. Install the sprinkler in the tee using the Model FC wrench.The Model FC wrench has a socket drive which is inserted into the sprinkler's cup and around the body r 1 of the sprinkler prior to installation of the sprinkler. Do s NOT wrench any of the part of the sprinkler/cup assem- bly. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to maximum installation torque is 22-30 Ib-ft Model G4/G5 Model G4/G5 SR Gasket (30—40 N-m). When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken OR Gasket Cover Plate to prevent damage to the sprinkler. Reinstall the protec- Cover Plate (FM Approved) tive cap following installation of the sprinkler, until the (cULus Listed) cover plate is installed. Model G4/G5 OR Gasket and Model G4/G5 SR Gasket cover a. Alternatively,where access to the outer tube of the sprinkler_is available, the Model G5-56 Dry sprin- plates are sold as assembled units including both the cover kler may be installed using a pipe wrench. The plate and gasket.Model G4/G5 OR Gasket and Model G4/G5 protective cap should not be removed to install SR Gasket cover plates and gaskets are not interchangeable. the sprinkler with a pipe wrench.The pipe wrench Installation Instructions shall only be permitted to interface with the steel outer tube portion of the sprinkler (Item #8 in Model G5-56 Dry sprinklers must only be installed in stan- Fig. 4). Do NOT wrench any other portion of the Bard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) sprinkler/cup assembly.A pipe wrench can install pipe tees in the horizontal position,even at branch line ends. the sprinkler into the fitting with a large amount Model G5-56 Dry sprinklers shall not be installed into elbows of torque; consideration should be given to the or pipe couplings located on drop nipples to the sprinklers. need for future removal of the sprinklers because In all installations, including into CPUC piping,the dry sprin- the installation torque will have to be matched or kler shall be installed with protrusion into the fitting in accor- exceeded to remove the sprinkler. The recom- dance with the installation diagrams in this Bulletin. mended minimum to maximum installation torque Installation of the Model G5-56 Dry sprinkler is not recom- is 22-30 Ib-ft(30—40 N-m). mended in copper pipe systems, as this may reduce the 5. To install the cover plate,remove the protective cap and life expectancy of the sprinkler. Do not install Model G5-56 install the cover plate by hand turning the cover in the Dry sprinklers with the standard (long)inlet fitting into CPVC clockwise direction until it is tight against the ceiling. For adapter fittings or tees that have an internal obstruction(see Model G4/G5 OR Gasket and Model G4/G5 SR Gas- Fig. 3); this will damage the sprinkler, the fitting, or both. A ket cover plates, the gasket should be attached to the short inlet("PL")version of the Model G5-56 Dry sprinkler is flange of the cover plate skirt only. Do not glue the gas- available for use in existing installations with CPVC adapter ket in place or allow the gasket to overlap both the cover fittings or tees having an internal obstruction; Model G5-56 plate and the flange of the skirt. 3. MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER - -- WET PIPE INTO THE 1 INCH NPT SIDE OUTLET EXPOSED BARREL OF A MALLEABLE IRON TEE FITTING AMBIENT -L----- __ PER ANSI B 16.3(CLASS 150) AMBIENT TEMPERATURE __ TEMPERATURE -- -- -- ____ OR CAST IRON THREADED TEE FITTING OF PROTECTED 40°F/4°C 50°F/10°C 60'F/1 6'C ; -� i � PER ANSI 16.4(CLASS 125)ONLY. AREA'AT THE DISCHARGE END EXPOSED MINIMUM BARREL LENGTH** OF THE SPRINKLER (FACE OF TEE TO TOP OF CEILING) �__yllit== Ls-1 I-zJ __ ___IN.(MM) IN.(MM) IN.(MM) IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 40°F(4°C) 0 0 0 CAUSE CONDENSATION ON THE EXPOSED 30°F(-1°C) 0 0 0 DRY SPRINKLER,CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION,FOAM 20°F(-7°C) 4(100) 0 0 - _- INSULATING TAPE OR EQUIVALENT. 10°F( 12°C) 8(200) 1(25) 0 0°F(-18°C) 12(300) 3(75) D MINIMUM (HEATED AREA) IF NECESSARY,SEAL THE CLEARANCE SPACE 10°F(-23°C) 14(350) 4(100) 1 25 EXPOSED AROUND THE SPRINKLER CUP TO AVOID ( ) BARREL LEAKAGE OF AIR INTO THE PROTECTED -20°F(-29°C) 14(350) 6(150) 3(75) LENGTH AREA. -30°F(34°C) 16(400) 8(200) 4(100) CLEARANCE J DO NOT BLOCK VENT HOLES ON TOP-OF-CUP. HOLE -40°F(-40°C) 18(450) 8(200) 4(100) DIMENSION -50°F(-46°C) 20(500) 10(250) 6(150) _60°F(-51°C) 20(500) 10(250) 6(150) INSIDE SURFACE OF FOR AMBII_NI 1LMPERAIURES EXPOSED TO THE DISCHARGE INSULATION, WALL, OR CND OF II IE SPRINKLER THAT OCCUR BETWEEN THE VALUES CEILING I IS 1), USf_ TI-IF NEXT COOLER TEMPERATURE. [HE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS 11-IF "A" DIMENSION. THE MINIMUM EXPOSED BARREL 1 LNC11-I IS BASED ON A PROPERLY SEALED PENETRATION WITH COVER PLATE A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF CEILING 30 MPH (A8 KM/H). LONGER EXPOSED BARREL LENGTHS WILL III-1-P AVOID FREEZING OF THE WET PIPING WHERE HIGHER WIND VF_LOCITY IS EXPECTED. (PROTECTED AREA) 051FG02A *** THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED 35/16"DIA. I ROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSUI_AFION, WALL, OR CEILING LEADING TO THE COLD SPACE, WIIICIIEVFR IS CLOSEST TO THE FITTING. Fig.2 F *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction;this will damage the sprinkler,the fitting,or both. Short inlet("PL")versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet("PL")should only be installed in CPVC fittings of wet-pipe systems. In all cases,verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal Obstruction No Internal Obstruction � 1 i Female Female Pipe Pipe Thread­-' Thread__,-"�o CPVC Fitting with Internal Obstruction CPVC itting - No Internal Obstruction Shorter ' Longer Inlet Inlet Male Male Pipe � p � Pipe i Thread Thread II i -77 Dry Sprinkler Dy Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION COMDRYDET2 Fig.3 5. Maintenance Ordering Information ' The Model G5-56 Dry should be inspected and the sprin- Specify: kler system maintained in accordance with NFPA 25. Do 1. Sprinkler: Model G5-56 Dry not clean sprinklers with soap and water, ammonia or any 2. Threads: [1-inch NPT-standard][ISO7/1 R1 -optional] other cleaning fluids. Replace any sprinkler that has been 3. Inlet Length: [Standard][Short ("PL")—for existing wet- painted (other than factory applied) or damaged in any pipe installations only] way. Concealed sprinklers cover plates can not be painted 4. Cover Plate Finish: [White][Chrome][Special Applica- in the field, after installation or have any other coating ap- tion—Specify] plied other than the factory finish. A stock of spare sprin- 5. Sprinkler/Cover Plate Temperature Rating: [Ordinary— klers should be maintained to allow quick replacement of 165°F sprinkler with 135°F cover plate][Intermediate— damaged or operated sprinklers. Prior to installation, sprin- 212°F sprinkler with 165°F cover plate] kler should be maintained in the original cartons and pack- 6. Nominal Sprinkler Length (face of fitting to face of aging to minimize the potential for damage to sprinklers ceiling - "A" Dimension from Fig. 1): [Specify length — that would cause improper operation or non-operation. Lengths available from 4'/a inches to 48 inches(108mm Engineering Specification to 1219mm) in 1/4-inch (6.35mm) increments] Model G5-56 Dry Pendent Concealed Sprinkler Dry pendent sprinklers shall be dry pendent concealed sprinklers with a flat cover plate. Sprinklers shall be cU- Lus Listed as Quick Response for Light and Ordinary Hazard applications as well as FM Approved as Standard Response. Sprinklers shall be available in lengths from 4'/a inches (108mm) to 48 inches (1219mm) in 1/4-inch (6.35mm) increments based on face of fitting to finished ceiling distance. Sprinkler length shall be selected to pro- vide the Exposed Minimum Barrel Length based on the minimum design temperature in the protected area and the minimum temperature in the conditioned space where the barrel is located in accordance with the Manufactur- er's written installation instructions. Sprinklers shall have [1-inch NPT][ISO 7-1 R1] threaded inlet fittings with [stan- dard length inlets designed for use with wet- or dry-pipe sprinkler systems][short length inlets designed for use with wet-pipe sprinkler systems having pipe fittings with internal obstructions that prevent the insertion of standard length inlets]. Sprinklers shall have a PTFE coated beryllium nick- el Belleville spring washer inlet seal and brass alloy cap that prevent water entry from the sprinkler system piping into the sprinkler prior to actuation. Sprinklers shall have a fast-response fusible link that controls the movement of the inlet seal and cap through a mechanism consisting of link arms, a seat adapter, an orifice adapter, an inner tube, and a yoke. Sprinklers shall use a drop down deflector supported by tapered pins. Sprinklers shall have a galva- nized steel cup for threaded attachment of the flat cover plate assembly. Cover plate attachment shall provide up to'h-inch (13mm) of adjustment. Sprinklers shall be [Ordi- nary temperature classification, 165°F (74°C), with 135°F temperature rated cover plates][Intermediate temperature classification, 212°F, with 165°F temperature rated cover plates]. Cover plates shall be[solid][perforated]with facto- ry applied [White][Chrome][Special Application—Specify] finish. Dry pendent concealed sprinklers shall be Reliable Model G5-56 Dry(SIN RA5114). 6. MATERIAL SPECIFICATIONS 5; ITEM# DESCRIPTION MATERIAL r_jIli;hj f —11 1 BODY,MACH. DZR BRASS 1 p-- %2} 2 DEFLECTOR COPPER ALLOY 3 DEFL.SPLITTER BRASS ALLOY 4 DEFL.PIN STAINLESS STEEL 5 MEGA-INLET DZR BRASS 6 LINK ASSY. NICKEUBERYLLIUM NICKEL 113 - —' ;\\`• \\ 7 LEVER COPPER ALLOY 8 OUTER TUBE GALVANIZED STEEL \ E \ 9 INNER TUBE BRASS ALLOY ` 10 FLIP DISK BRASS ALLOY 11 CAP BRASS ALLOY n / 12 WASHER PTFE COATED BERYLLIUM NICKEL l� 1 13 SETSCREW STAINLESS OR ALLOY STEEL a 14 LOAD SCREW STAINLESS STEEL v 15 BOTTOM CUP GALVANIZED STEEL `! 16 TOP CUP GALVANIZED STEEL 17 ADJ.SEAT ADAPTER BRASS ALLOY 18 YOKE BRASS ALLOY 17 11 A � 19 CLOSURE YOKE BRASS ALLOY .__._i.._.__._......_...__...._ 20 ORIFICE ADAPTER BRASS ALLOY WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) o Csr r 051 FG04 �� r �llliii Fig.4 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. ® Recycled 00 (800)431-1588 Sales Offices Paper Reliabi (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.01/20 P/N 9999970480 F -1 "0 From 3elow YO Down to Cellar and FD 59 4 °P 411 o1 V/ O11A 1 , FD Connectio 2"0 Dow t ell r 25Class K .10 Fire Extingui99 26 �-------- A@ Dining Room A I I O 1 2"0� 33 58 uo Ladies Lav 11 '�11to '-1„0 24 A A 1„ 1 0 I I 39 40 11 10 A 22 ❑° 1 g A 17 E). r=%7 =HydraLICalculation --------0 Froma #4 1 211 I I 1 0 Below i i ❑ 4 �— Mens Lay. Hydraulic Calculation 48 25 49 2”0 U to 1"0 27 A Area #3 A 29 57 2nd Flo 0 11 A 1 I I O 1 L �� J ia 1„0 21, 1 211 41 A 24 A 4"0--' 56 2DA -1 0 45 32O m O O 2" 211 23 211 " i--i 46 44 42 1"0 olnsl F] 52 I I 1"0 1"0 54 51 50 A 26 A 111 4 \-2"0 O I 29 ❑ 4 110-----� I ❑ I L J I I F1_ 11101110 1,10 I I ,(J I I I I I Kitchen A L-- J 1'0 31 A 14 Al 13 A 12 1110 30 []Fj A 15 Hydraulic Calculation Area #2 28 A A 27 23 Al O ❑ ❑ ❑ 1-1 ❑ ❑ El ❑ ❑ El Living Room Q QF11 F1 O El- El ULIE] E1_1E1 Bedroom O O Water Main 1st Floor Sprinkler Plan 2nd Floor Sprinkler Plan 3 65 6 110 XUp 64 6 1101 From Above 73 ro aIJF m❑ FD Connectio \3"o 38 211 0 B 1110 111 11,01"0 O B B B 12 37 11 10 prinker Design Data 00 * Hydrant Test Data- Pressure Hydrant-Sound Avenue and Love 2"0 59 Lane Water Motor Gong on Exterior Wall Flow Flow Hydrant- Love Lane and Pike Street Legend B110 B 1"0 �1"0 B (1110 B �1 5 Date- November 22, 2021 ® A-Ceiling Pendant Sprinkler- Reliable Model G5-56 Static Pressure-66 psi p B-Attic Pendant Sprinkler- Reliable Model F1 FR - Og 36 �7 O - Residual Pressure-54 psi 0 C- Dry Sprinkler- Reliable Model DH56 v 39 - Flow-2,026 gpm Hydraulic Calculation 60 NFPA 13 Sprinkler Piping 2"0 Area #1 — — Below Ground Piping 3110 2nd Floor O Node Identification used in Hydrolic Calculations Light Hazard 1 Density-0.1 gpm/ft2 Multiple Heads NFPA - 13 B Restaurant Service Areas 1"0 1"0 1"0 O Ordinary Hazard 1 B f B f C Density-0.15 gpm/ft2 Multiple Heads O 35 O3 O 4"0-\ Restaurant Seating Areas ,. Light Hazard 1 • Density-0.1 gpm/ft2 Multiple Heads as tags 1'848' ,' ! Cellar Areas Ordinary Hazard 1 p :,,,._, •�,,� Density-0.15 g0mlft2 Multiple Heads 681 or Cellar Sprinkler Plana = Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education Scale: 1/4" V-0' Condon Engineering, P.C. Pookaberry Cafe Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Drawn by : JJ C 1755 Si sbee Road 140 Pike Street Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing CJ the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Mattituck, New York 11952 Mattituck New York Land Surveyor shall affix to the item his/her seal and the notation'Aftered by'followed by his/her Date 2-25-2022 signature and the date of such alterations,and a specific description of the afteration. (631) 298-1986 1"0 Schedule 40O Steell Fire Sprinkler System Specifications Fire Suppression System Scope of Work- Furnish all materials and labor required for a proper and complete installation of the fire sprinkler suppression system and related work including but not limited to: sawcutting, pipe, pipe hangers, supports, bracing, heads, signage, valves, fittings, testing, inspections &cleanup. the fire sprinkler contractor shall be licensed in Suffolk County with the fire marshal's office. General-Construction shall conform to the most current editions of the building code&fire code of New York State, NFPA 13, National Electric Code, local zoning ordinances and fire marshal office. Contractor shall comply with all provisions, requirements, regulations and directions as outlined in the latest OSHA requirements. Fire Sprinkler System-The following conditions shall apply specifically to the contractor and his fire protection licensed subcontractor. a. The contractor shall furnish and install all items whatsoever that may be necessary to complete a working and finished fire protection system of the Electric Heater character and type specified. SAFE-T-COVER Model400SN-AL in ed Side of Box Cover rA able Model G5-56 QR Sprinkler g b.All work must be in accordance with the requirements of the owner's insurance company, and shall comply with the latest edition of NFPA 13, and Wilkins Model 375 OSY 4"0 RPZ 8" Min. K=5.6 NFPA 13R and all local ordinances, the New York State Fire Code, and.the local fire Marshall's office. The plans and specifications shall be used Scale=NTS as an outline only. this contractor shall be responsible to obtain written approval of the complete installation from the local fire marshal. In addition, all work must meet with the engineer's approval. c. Work in this section includes, but is not limited to, providing all the following material, equipment, products and labor for a complete and approved sprinkler system: 1. Installation of new sprinkler cross main and branch lines 2. Installation of new sprinkler heads 3. Any and all items. appurtenances, etc. necessary to hang, support, anchor, brace, etc. equipment furnished under this contract 4. All sprinkler lines are to be filled with Noble Model PG38 or equivalent antifreeze solution. 5. One year warranty Front Access Pane O 6. Testing Test Cocks Must be Positioned 30"Clearance Min. When to Facilitate Testing (30" Minimum Clearance) VO Schedule 40 Steel d. The contractor shall be responsible for submitting all required hydraulic calculations, plans, documentation, applications, fees and payments etc. for Enclosure is Opened obtaining a fire sprinkler permit from the local fire Marshals office. 78" e. Install horizontal piping pitched to low points and in a manner to make it possible to test and empty the entire system; provide valves and piping of sizes and in locations as indicated by and in accordance with the requirements of NFPA 13. Wilkins Model 375 OSY 4" ,a F PZ SAFE-T-COVER Model 400SN-AL f. Coordinate routing of cross main and branch piping with existing ductwork, piping, lighting, insulation batting, etc. in existing ceiling. offset routing of or Equivalent piping as required to avoid all existing conflicts. Equipped with Heater to protect RPZ from freezing g. Ream and remove burrs carefully at thread pipe cuts. use one-piece continuous length pipe between sprinklers avoiding the use of couplings except where absolutely necessary. h. Screw joints shall be made up with pipe paste applied to male threads only. ream pipe as necessary to make bore at end of the pipe the same as s3 B Reliable Model F1 FR56 the inside diameter of the pipe. — -� — s4 - - - K=5.6 i. Materials: Scale=NTS 1. Sprinkler system piping and fittings: interior piping: Schedule 40 black steel pipe. fittings for threaded pipe shall be malleable iron fitting 150 psi. c - V-D rain Port M 2. Reducers: reductions in pipe sizes shall be made with one piece reducing fittings. bushings will not be acceptable. co 3. Sprinkler heads: sprinkler heads shall be Underwriters'approved and listed for use intended (pendent, flush, upright or sidewall type) installed ::: :;': ',;*' as indicated on the drawings. all piping for concealed and recessed heads shall be concealed or run above the ceilling. head. fusible solder link type, or glass bulb type, temperature rated for specific area hazard. sprinkler heads shall be as manufactured by Reliable Model G5-56 in finished ceiling spaces on the first and second floors and Reliable Model F1 FR in the cellar. The sprinklers with a'K'factor of 5.6. 6" ' IIS u p rt Stanchions "'' 4. Hangers and supports: hanger rods shall be hung from structural members with suitable clips or beam clamps as necessary. piping shall not be supported from lighting, ductwork, other piping or equipment. all hangers shall be plumb. hangers and supports shall be UL approved and shall comply with NFPA standards and owner's insurance requirements as to size,type and spacing. Manufacturer: clevis type and roller type Concrete Slab Per hangers shall be hot dipped galvanized as manufactured by ITT Grinnell co., Central Iron, Leifried, or equal. Manufacturer's Specifications :a. 5. Test and drain valves: bronze body globe, rubber discs, 300 psi c.w. non-shock, similar to Fairbanks, figure no. 4591-3 or 4691-3 or approved Note: equal. The Siamese Connection 62 65 6. Unions: couplings and unions shall not be used except where pipe is more than 20' in length between fittings. screwed unions shall not be used must be Down Stream of " ' �' From Water Main on pipe larger than 2". Coupling and unions of other than screwed type shall be of the es approved specifically for use in sprinkler systems. .f. tYP PP P Y P Y the RPZ 7. Signs and charts: store and save existing inspector's test sign for re-installation by this contractor. 4" Ductile Iron 4" Ductile Iron Insulated Freezer, j. Inspections and Testing Water Line Water Line r Cooler Structure or Exterior Framing 1.After installation is complete, but before the piping is furred in or covered over, the contractor shall provide instruments and equipment, secure, Fi re I i n e Service and RPZ perform and pay for all tests necessary to produce satisfactory evidence of the correctness of the installation and acceptance thereof by the local fire marshal. Valve P I a nDischarge End of ry Sprinkler 2. All new piping and equipment shall be hydrostatically tested as per NFPA 13. Scale: 1/2" = 1'-0" in Cold Area C Reliable Model DH56 Sprinkler O - K-5.6 Scale=NTS b - ,0516 Scale: 1/4„ = 1,-0' Condon Engineering, P.C. Pookaber Cafe Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education ry Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Drawn by : JJC 1755 Si sbee Road 1�0 Pike Street Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing 9 lea the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer, ineer,A chitect,or Mattituck, New York 11952 M at�itu ck, New York Land Surveyor shall affix to the item his/her seal and the notation'Altered b followed b his/her Date : 2-8-2022 signature and the date of such alterations,and a specific description of the alteration. (631) 298-1986 0 r PS UP DN. p O Fir Sprinkler Riser °' TS Class K Fire Extinguisher 0 os S ED H a Ladies Lay. Men's Lay. Kitchen Front Entrance m PS ANN ❑ 1:1 F Ll — ❑ ❑ I i [-1 F1I i I � , I I X I F]--F] I i [PSI i Dining Room O F1 F1 F ❑ 1:1 ❑ 1:1 1:1 �nox Box 10 F11 Fl. [1-1:1 -------- � I I I I ❑ O 1st Floor Plan � Dining Room I I S I I I I t--------A c S F- --I I I � • I I I I I I O Kitchen I I I I , UP Wl� PS 00 QS QS O c S ao Living/Bed Roo Q Q0 OOF— O Bedroom O O 2nd Floor Plan o 0 a NLL urnaces STORE ROOM F— r Erg C01i - NAR 1 0 2022 Ji BUILQINUEPT THO1.C' WALK-IN COOLER 0 0 ❑ 011:8 48 1848 1848 M lu aU Cellar Plan f y., f New Water Heater `- - � * Rheem Model HE55-160 Natural Gas * 55 Gallon * 160,000 BTU/Hour Input Scale:711 = 1'-0' Condon Engineering, P.C. Pookaber Cafe Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Drawn by : JJC 1755 Si sbee Road M 140 Pike Street Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing gVAnl the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Mattituck, New York 11952MattitUCk New York Land Surveyor shall affix to the item his/her seal and the notation"Altered by'followed by his/her Date : 3-9-2022 631 298-1986 signature and the date of such alterations,and a specific description of the alteration. Sequence of Operation 1. Activation of a smoke/heat detector device shall illuminate alarm LED on control panel LCD screen and annunciator, sound all alarm horns, strobes, in temporal 3 pattern, send an alarm signal to the central station, and shut down all fans, boilers, clothes dryers, and the clothes cleaner. 2. Activation of a pull station shall illuminate alarm LED on control panel LCD screen and annunciator, sound all alarm horns, strobes, in temporal 3 pattern, send an alarm signal to the central station, and shut down all fans, boilers, clothes dryers, and the clothes cleaner. 3.Activation of a flow switch shall illuminate alarm LED on control panel LCD Symbol Description Manufacturer Model No. Qty. screen and annunciator, sound all alarm horns, strobes, in temporal 3 pattern, Vista-128FBP/ send an alarm signal to the central station, and shut down all fans, boilers, clothes FRCP Addressable Fire Alarm Control Panel Honeywell 1 V128FBP-24 dryers, and the clothes cleaner. ANN Liquid Crystal Display Fire Annunciator Firelite ANN-80 1 4.Any system fault or supervisory condition shall Illuminate fault/supervisory LED (2) 18 Gage Twisted on the control panel and annunciator, activate for malfunction of manual pull S Addressable Photo Electric Smoke Detector Honeywell Shielded Cable station, smoke detector, heat detector, horn strobe, AC power, battery, ground 0 yw 5193SD 21 fault or phone lines. PS Addressable Manual Fire Alarm Pull Station Firelite BG12LS 5 5. Activation of a CO detection device shall not set off the fire alarm devices, shall North Cellar Walk in Cooler South Cellar Furnace#1 Furnace#2 shut down all fans in the building, CO alarms shall annunciate using a temporal 4 pattern, and send an alarm signal to the central station, will not activate anyHeat Detector, Fixed 135 Degree System Sensor 5603 3 S S S S S S S S C S PS s P g One Telephone Line& strobes. Wireless Connection forLadies and Mens and Dining Mk Heat Detector, Fixed 135 Degree and ROR System Sensor 5601 0 Central Station Front Entrance Kitchen iC Room Specifications Handicap Lay. Handicap Lay. Communication H H PS S S CO S PS ® Heat Detector, Fixed 200 Degree System Sensor 5604 0 FAC P TS S PS S S 1. All fire and CO alarm equipment and wiring to be installed according to the latest National Electric Code,and the latest edition of NFPA-72 and as required Apart. by the Fire Marshal. ® Photoelectric Duct Smoke Detector System Sensor D2 2 Annunciator Apart. Apart. Apart. Apart. Living/ Panel Hall Dining Apart. Hall Apart- Bedroom Living/ Bedroom 2. Smoke and heat detector spacing 30' max. Room Kitchen Closet Bedroom Closet Bedroom Closet ® Control Relay Firelite CRF-300 4 S0 S PS H S SCO S S C S 3. All conductors must test free of opens, shorts, and grounds, prior to final testing. \_r�/ Audible/Strobe, Wall Mounted System Sensor P2R 6 4. All fire alarm wiring run in conduits shall not be run in conduit with other Strobe, Wall Mounted System Sensor SR 3 120 (2) 18 Gage Twisted electrical systems. / \ vac Wiring a Weatherproof Audible/Strobed System Sensor P2RK 2 5. Grounding must comply with the National Electric Code. Grounding must be /y,�p\ No. 12 AWG single conductor unless otherwise noted. HS Horn/Strobe, Ceiling Mounted System Sensor pC2R 0 6. All wiring to sensing devices are to be No. 18 AWG copper or as specified by North Cellar South Cellar the manufacturer.All signaling devices are to be wired with a minimum of No. 18 AWG copper or as specified by the manufacturer. CO CO Detector Firelite C01224TR 3 7. All equipment is to be installed in accordance with the manufacturers' F—T-1 Alarm Communicator Honeywell 3G/4G specifications. Front Front Ladies and Mens Kitchen Dining Front Apartment Dining Lay. Room Entrance Room 8. Install detectors a minimum of 3'-0"from an return air registers. Knox Box KNOX 3200 1 Entrance Entrance Handicap Lay. � y g / \ / \r\7/ 9. After alarm indication, all fans shall be manually reset independent from FACP ® Water Flow Switch System Sensor WFD 1 system reset. Furnace#1 Furnace#2 HW Heater#1 HW Heater#2 10. As per ADA all devices shall be mounted as follows: ITS] Sprinkler Tamper Switch System Sensor OSY2 1 -Manual pull stations 48"o.c. R R R ® -Alarm indicating appliance 80"a.f.f. 11. Strobes shall be wired to remain active after silence function is performed. 12. All fire alarm devices shall be wired to communicate with the fire alarm control panel located in the Laundry office. 13. Install duct smoke detectors in the supply ducts of the HVAC system and shut off relays at the fan. 14. The fire and CO alarm system is to shut down all fans in the building when an alarm is activated. 15. Annunciator panel and alarm horn/strobe are to be water proof construction. 16. CO alarms shall be UL2034 listed and CO detectors shall be UL2075 listed. 17. Wireless smoke, heat,and CO detectors are allowed to be used. Celling 3' Min. Ceiling Diffuser Smoke Detector Hom/Strobe & Strobe Device 10, Pull Station ,.:; •5y L DO FIRE 00 zo 051 -1 LL Floor Typical Device Mounting Heights Scale: 1/4" = V-0' Condon Engineering, P.C. Pookaber NTS Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education ry Cafe I 1 11011111111 AM Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Drawn by : JJC 1755 Si sbee Road 40 Pike Street Professional Engineer,Architect,or Land Surveyor,to alter any item in anyway.If an item bearing 9VA 2 the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Mattituck, New York 11952M attituck New York Land Surveyor shall affix to the item his/her seal and the notation"Altered by'followed by his/her Date : 3-9-2022 signature and the date of such alterations,and a specific description of the alteration. (631) 298-1986 l R-102 RESTAURANT t E SUPPRESSION SYSTEM FIR. s i � Jyrl DESIGN, INSTALLATION, RECHARGE,AND MAINTENANCE MANUAL'= = r • - � �� EELLii I ' tis'� L�,3•Y w.3' � • yA. LLY h: ' yyfifi4 1� i Ft. - 'SS39.sYkf TCS�diYYv.IG'CK� ^2::Gi'�3Li�S.tYTRSt:.LDE'fi'y%'1^1Y2:'�3'- .�i SECTION III—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-1 7-1-09 REV,6 EXTINGUISHING AGENT ANSULEX Low pH Liquid Fire Suppressant(1.5 gallon—Part No. "ANSUL-AUTOMAN"REGULATED RELEASE ASSEMBLY 79694 or 3.0 gallon—Part No.79372)is a potassium-based solu- (MECHANICAL) tion designed for fast knock-down and suppression of grease- related fires.The agent is shipped in plastic contairlers which pro- NOTE:AGENT TANK MUST BE vide one 5 P V charge.complete tank Refer to Section ,Page -2.1,for ORDERED SEPARATELY ® o p g ( g OR SEE PAGE 3.4 o c, maximum agent fill capacity.) Agent storage life expectancy is �"o twelve years and can be stored at a temperature of—40 OF to 130 RELEASE OF(-40°C to 54°C).Note:When installing agent in R-102 sys- MECHANISM tem,temperature range is 32 OF (0 °C) to 130 OF (54 °C).The distributor must record the batch numbers and date of shi ment receipt to be filed with each installation record. �YA� "ANSULEX"LOW pH LIQUID FIRE SUPPRESSANT 1 QREGULATOR I SHIPPING WT.25 LB(11 kg) I FIGURE 2 i OOD1;B 3.0 GALLON 1.5 GALLON SHIPPING WT.35 LB(16 kg) SHIPPING WT.19 LB(9 kg)jl 000138 000137- REGULATED RELEASE ASSEMBLY(ELECTRICAL) FIGURE 1 The ANSUL AUTOMAN Regulated Electrical Release.Assembly REGULATED RELEASE ASSEMBLY(MECHANICAL) (Part No.429856) is'identical to the mechanical version except it also contains a factory installed 120 VAC solenoid and electrical The ANSUL AUTOMAN Regulated Mechanical Release Assembly switch. (Part No. 429853) contains the'regulated release mechanism,, expellant gas hose for agent tank hookup, and enclosureiknock- The solenoid is used to provide electrical actuation of the release I mechanism.The electric switch is used to protect the solenoid by outs to facilitate installing actuation piping;expellaht piping detec- tion system; and additional equipment. This regulated naAdditional electrical switches can be added as required for assembly is used in single,double,and multiple tank syste��',n1'1s anndd auto- matic equipment and gas shut-off accessories,as well as Initiating must be mounted to a rigid surface.The release mechaniDm can audible and visual alarms. be used to interconnect both the actuation and expellant gas lines as required per system design.The regulator is designed to allow "ANSUL AUTOMAN"REGULATED RELEASE ASSEMBLY a constant flow of gas into the tank at 110 psi (7.6 bar)wlen the (ELECTRICAL)* system is actuated.The agent tank must be ordered separately. NOTE: NK MUST BE In single, double, and multiple-tank sstems, the Provided expel- ORDERED (VD � lant gas hose connects the agent tank to the bottom outl6t of the SEPARATELY regulator. In double and multiple-tank system configurations, the OR SEE PAGE 3-4 back outlet of the regulator is used as an expellant•gas feed for one additional tank-enclosure or tank-bracket hookup.The enclo= REGULATOR m SWITCH sure contains the required knockouts to facilitate this con*tion. rection. If a pressure switch is to be attached to the regulator,additional fit- tings are required. ° I The tank is mounted within the enclosure.The tank contains an SOLENOID adaptor/tube assembly with a burst disc union.The burst disc helps prevent siphoning of the agent up the pipe due to significant ° temperature fluctuations in the area where the tank is located.The tank is stainless steel and, under normal conditions, requires hydrostatic testing every twelve years. The detection and additional equipment required per system design are connected to the release mechanism.The enclosure SHIPPING WT.34 LB(15 kg) contains knockouts to facilitate detection and additional hookups. The system can be actuated automatically or manually.Automatic actuation occurs when a fusible link within the detection system FIGURE 3 Separates in a fire condition. Manual actuation of the system 0001 occurs when personnel pull on the remote manual pu I station "NOTE:ANSUL AUTOMAN Regulated Electrical Release,Part No.429856,is not pull ring. intended to be used with electric detection. I I SECTION III—SYSTEM COMPONENTS 4 UL EX3470 ULC EX3470 Page 3-2 REV.6 7-1-09 REMOTE MECHANICAL RELEASETheban I bracket is constructed of mild steel and painted red.It is The Remote Mechanical Release, Part No. 433485, is used' to designed 16r'mounting the tank in a minimum amount of space. actuate up to five (5) R-102 regulated actuators. The remote The�Dracict Assembly can only be utilized with 3.0 gallon tanks mechanical release utilizes a 101-10 carbon dioxide cartridge as (Part No. 29862), the actuation pressure to operate the regulated actuators. The release is housed in a stainless steel enclosure. BRAKE SSEMBLY �! MOUNTING BRACKET I ► I,I RELEASE I l O MECHANISM i i 111 I I'I I I it I 1 I ° SHIPPING WEIGHT: 20 LB(9.1 kg) FIGURE 4 ,.i SHIPPING WT.7 LB(3 kg) (0 749g FIGURE 6 SINGLE TANK ENCLOSURE ASSEMBLY 0001A1 The Single Tank Enclosure Assembly(Part No.429870) is useid in REGULATED ACTUATOR ASSEMBLY double and multiple-tank systems and must be mounted to a;rigid The , egulated Actuator Assembly (Part No. 429850) contains the surface near the regulated release or regulated actuator assembly regulator, pneumatic actuator, expellant as hose for agent tank its expellent gas line will be connected to, f hook° ,I ' p g g p,ands ienclosure knockouts to facilitate installing expellant pip- The enclosure is designed for mounting either a 1.5 gallon (Part I Ing. This`assgmbly is used in multiple-tank systems and must be No.429864).or a 3.0 gallon tank(Part No.429862) In a minimum moue"ted tot al'rigid surface. amount of space. The rle6ulaton contains two outlets 1350 apart.One outlet is used ENCLOSURE ASSEMBLY l to int' ,connect the expellant gas hose to the enclosed agent tank. ', The$t'he y.ou tlet connects an expellant gas line to an additional o 40 ,enclo ure orlbracket assembly.The regulator is designed to allow NOTE:AGENT TANK MUST ° ° ;: ,a colstant flow of nitrogen into each agent tank connected (two BE ORDERED 0 t-tanks maxi um) at 110 psi (7,6 bar). SEPARATELY s OR SEE PAGE 3-4 �: ,The pneumatic actuator is designed to puncture the expellant gas ,cartridge;seal;upon receiving pressure from the regulated release 0 asser,Pbly actuation piping.The enclosure contains a knockout to ;facilitate distribution piping hookup. 0 REG 1 LATED ACTUATOR ASSEMBLY MOUNTING ENCLOSURE NO E:AGENT TANK MUST BE ORDE9ED I PNEUMATIC �� ;{ SEPARATELY ACTUATOR SHIPPING WT. I OR SEE PAGE 3.4 ASSEMBLY 13 LB(6 kg) REGULATOR ' I I FIGURE 5 I ` 000142 � is RED PAINTED BRACKET ASSEMBLY r SHIPPING WT. The Bracket Assembly (Part No. 429878) is used in double and 19 LB(9 kg) multiple-tank systems and must be mounted to a rigid surface near the regulated release assembly or regulated actuator asserR�ply FIGURE 7 that its expellant gas line will be connected to. 000143 I SECTION —SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-3 4-1-06 REV.8 I I AGENT TANK ASSEMBLY OEM REGULATED ACTUATOR ASSEMBLY The agent tank shipping assembly (3-Gallon, Part o.142 862, The OEM Regulated Actuator Assembly, Part No. 418691, and 1.5 Gallon, Part No.429864)consists of a stainle$�ste,e tank includes the regulator,pneumatic actuator,expellant gas hose and and an adaptor/tube assembly.The adaptor/tube a mbl) con- OEM bracket. Also available is an OEM Regulated Actuator tains a burst disc.The burst disc prevents agent le geld e to Assembly with all the above mentioned components except for the significant temperature fluctuations in the area I whet ;the it I nk is bracket.This assembly is Part No.418522. located. Under normal conditions, the tank requirel hydr'static III testing every twelve years.The date of manufacturei tamp d on the tank nameplate. The tank is shipped uncharged and must be fill s wl I only ANSULEX Low pH Liquid Fire Suppressant during i' alla�N n. I I dal TANK ADAPTOR/ TUBE ASSEMBLY Id y 3 GALLON SHIPPING WT. 7 LB(3 kg) { 1.5 GALLON SHIPPING WT. 5 LB(2 kg) ji SHIPPING WT.4 LB(2 kg) TANK 0 AGENT I > FIGURE 10 III ! ` TWO.TANK ENCLOSURE ASSEMBLY > FIG JRE 8 The Two Tank Enclosure Assembly, Part No.429872, consists of 000140 twpp expellant gas hoses,two grommets, and the mounting enclo- St.re.The assembly is used in 9 gallon systems.It can be coupled OEM RELEASE/BRACKET ASSEMBLY with a 3-gallon regulated release assembly or a 3-gallon regulated ` (FOR OEM IN-CABINET USE ONLY) a8tuator assembly to give a total of 9 gallons of agent.Agent tanks The OEM Regulated Mechanical Release/Bracket ssey, Part m st be ordered separately. No. 79493, contains the same regulated release �iechl alsm as I I TIe tank enclosure is designed to mount in a minimum amount of the standard ANSUL AUTOMAN Regulated Rele se As embly. sl ace. The OEM Regulated Electrical Release/Bracket ssernb+ , Part >No.418054", is identical to the mechanical ver sion�IlexcepI it con- tains a factory installed 120 VAC solenoid and eII I tric',l I witch. These release/bracket assemblies must be installed in a; uitable equipment enclosure either horizontally or vertically They ontain all the necessary mounting and conduit holes n eded o fully ! SHIPPING WT. install the assembly.The agent tank is installed epai�at ly and 2s LBS(,2 kg) need not be bracketed once it is piped and fill,11. Not : OEM Release/Bracket.Assembl must be installed high Ihou Ih n cabi- net so that there is sufficient room to install and re r iove'icalrtridge. >"Note:OEM Regulated Electrical Release/Bracket Assembly, irt No.!!4 8054,is > not intended to be used with electric detection. FIGURE 11 ill I� i 002277 MOUNTING RELEASE tl •• / BRACKET MECHANISM 'I REGULATOR ;I I I SHIPPING INT. 10 LB(5 kg) IM6URIE9 ' 000,.14 I ( I 1 11f I I f i SECTION III—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-4 �I REV.7 4-1-06 24 VDC REGULATED RELEASE ASSEMBLY(ULC APPROVED AD T ONA SHIPPING ASSEMBLIES ONLY) The 24 VDC Regulated Release Assembly, Part No. 429859, is both hexel,asetor actuator mechanism and the agent tanktWhen used where electric,thermostat detection is required via the use of orde ing a c, m shipping assembly, order the following part a releasing control unit. This assembly consists of a 24 VDC num e.rs: ANSUL AUTOMAN II-C regulated release mechanism, expellant gas hose,and enclosure knockouts to facilitate installing actuation I Shipping Wt. piping, expellant piping, detection system, and additional equip- Part o: De cription Ib (kg) ment.Agent tank must be ordered separately, 430 9., 3. i!Gallon Mechanical Release 33 (15) The system can be actuated automatically or manually.Automatic ! Sh pping Assembly including: actuation occurs when the control panel receives a signal from the 42''853 Mechanical Regulated detection circuit.The panel then sends an electrical signal to the Release Assembly 24 VDC regulated release, causing it to actuate.When actuation 429862 3.0 Gallon Tank Assembly occurs,the gas cartridge is punctured,pressurizing the agent tank 4303 Oi' 1. Gallon Mechanical Release 30 (14) and discharging the agent through the distribution piping.Manual SH'pping Assembly including: actuation of the system occurs when personnel pull on the remote i 42 '853 Mechanical Regulated manual pull station pull ring. '', Release Assembly 42. 864 1.5 Gallon Tank Assembly NOTE:AGENT TANK MUST BE I'I ORDERED SEPARATELY 4303 91. 3.0 Gallon Regulated Actuator 36 (16) Shipping Assembly including: SHIPPING WT. 42850 Regulated Actuator Assembly 34 LB(15 kg) 42862 3.0 Gallon Tank Assembly 4303 6 1.5�'Gallon Stainless Steel Enclosure 18 (8) Shliping Assembly including: 142C$70 Single Tank Mounting Box j I Assembly i 421, 664 1.5 Gallon Tank Assembly i 41 511 Hose Assembly 43037r1-3.0IGallon Stainless Steel Enclosure 20 (9) FIGURE'12 I" Shl(ping Assembly including: OD2270 FI 42-870_ Single Tank Mounting Box (� Assembly I;!42,�62 3.0 Gallon Tank Assembly 41 511 Hose Assembly I . I 4303 4f11 6.0,'Gallon Stainless Steel Enclosure 40 (18) Shipping Assembly including: i42 872 Two Tank Mounting Box IIj Assembly 42 862 3.0 Gallon Tank Assembly(2) 4303 2 3.0 Gallon Mounting Bracket Shipping 20 (9) Assembly including: :421,378 3.0 Gallon Mounting Bracket �II Assembly 142( 62 3.0 Gallon Tank Assembly I i I I I I II r\ I i i SECTION III-SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-5 7-1-09 REV.8 l r, GAS CARTRIDGES NOZZLES The R-102 system uses gas cartridges to store nitro g n or carbon There are 11 types of discharge nozzles each designed to distrib- dioxide expellant gases under pressure until the syst m is actuat- ute the liquid agent in a uniform pattern throughout the hazard ed, at which time the cartridge,seal is punctured and;4he release area: gas expels liquid agent from one or more tanks thr ugh the dis- 1. 1W Nozzle 7. 245 Nozzle charge piping and out the discharge nozzles. I 2. 1 N Nozzle 8. 260 Nozzle Four nitrogen gas cartridges and three carbon dlo>ide c as car- 3. 1/2N Nozzle 9. 290 Nozzle tridges are available as shown in Figure 13. ' I 4. 3N Nozzle 10. 2120 Nozzle Cartridges noted as TC/DOT are both Transport Can da( C)and 5. 2W Nozzle 11. 1 F Nozzle Department of Transportation (DOT) approved. Car ridges noted 6. 230 Nozzle as DOT are Department of Transportation approved niy. Although these nozzles are similar in appearance and have Cartridge selection options are provided in Section I un er Tank certain common parts, the tip of each nozzle is designed for a and Cartridge Requirements. I specific application and must only be used in those areas. See NITROGEN GAS CARTRIDGES Nozzle Application Chart in Section IV - System Design, for individual nozzle usage. 3/8-18 NPT FEMALETHREAD v 7( 1 I 17 1 4 IN, T 43. cm) 7 7/8 IN (29558 m) (3 1/4 m) ( INTERNAL CUP 20 cm) (31.1 cm) STRAINER o( INSIDE BLO� I OFF RECESS FOR--�pp���gpp����pp pppp 21/2 IN. 21121N. 43116 IN. /16Ii C PVLOOP haXXX_X VENDOR (6.4 cm) (6.4 cm) (10.6 cm) (9 cm) CODE LT-20-R LT-30-R DOUBLE-TANK ! LT-I-101.30 NOZZLE (IF PRESENT) CARTRIDGE CARTRIDGE CARTRIDGE CAITRIDGE STAMPING 000145 000146 000147 00146 FIGURE 14 CARBON DIOXIDE CARTRIDGES 000002 _ Nozzle Identification Chart D Note:See Component Index for nozzle package shipping assem- bly part numbers. 11 518 IN. Nozzle 91N. 77/81N. (29.5,cm) Nozzle Nozzle Nozzle* Flow (zz.s 0m) (2o em) 1r Type Part No. Stamping No, Nozzle Material D i W Nozzle 419336 1W" 1 Chrome-Plated Body 0 1N Nozzle 419335 1 N** 1 Chrome-Plated Body 21N. 21/21N. 2l1/21N. 1/2N Nozzle 419334 1/2N 1/2 Chrome-Plated Body (5.1 cm) (6.4 cm) (1.4 cm) '3N Nozzle 419338 3N 3 Chrome-Plated Body 101.10000AR9000RIDGE 101-20AR0000161 TRIOGE 1i -30DGE 0 2W Nozzle 419337 2W 2 Chrome-Plated Body D FIGURE 13 230 Nozzle 419339 230 2 Chrome-Plated Body Additional cartridge shipping assemblies are available for 245 Nozzle 419340 245 2 Chrome-Plated Body European and Australian requirements. 260 Nozzle 419341 260 2 Chrome-Plated Body P-Cartridge European Australian TG/DOT 290 Nozzle 419342 290 2 Chrome-Plated Body Description Part No. Part No. Part No. 2120 Nozzle 419343 2120 2 Chrome-Plated Body LT 20-R 428440 428948 43429 1 F Nozzle 419333 1F 1 Chrome-Plated Body LT 30-R 428441 426553 , 423435 'Nozzle stamping may contain an additional letter indicating a vendor's code. Double Tank 428446 426563 423493 P-Stainless steel versions are available in the 1W nozzle(Part No.432527)and LT-A-101-30 428442 426555 423491 ° the 1N nozzle(Part No.435672). 101-10-CO2 428443 N/A 423439 SILICONE LUBRICANT 101-20-CO2 428445 N/A 423441 Dow Corning Compound 111, Part No. 78112, is available in a 101-30-CO2 428444 N/A 423443 5.3-ounce tube.Compound has excellent qualities for sealing and I.Note: For 101-10 cartridge, Part No.15850 is DOT only; lubricating system components. I i " y SECTION III—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-6 REV.7 7-1-09 SWIVEL ADAPTOR CONDUIT OFFSET ASSEMBLY >The Swivel Adaptor Assembly consists of a swivel nut,swivel body 'The conduit offset assembly, Part No.435961, is used to change and swivel ball.All are chrome-plated.The swivel adaptor allows direction of the wire rope on detection, mechanical gas valve,and any nozzle to be rotated approximately 300 in all directions.Swivel remote pull station lines.The conduit offset assembly can only be Adaptors must be ordered as a Swivel Adaptor Shipping used in the area where the conduit attaches to the regulated >Assembly, Part No.423572,which contains 25 Swivel Adaptors or release assembly. When using the conduit offset assembly, the >Part No.419385,which contains 9 Swivel Adaptors. maximum number of pulley elbows is still allowed.The Conduit Offset Shipping Assembly, Part No.436063, consists of 6 conduit /® 3/8-18 NPT offsets. FEMALETHREAD a CONDUIT COUPLING 3/8-18 NPT CONDUIT MALE THREAD I OFFSET 30 DEGREE ROTATION FIGURE 15 000003 CO qDUIT RUBBER BLOW-OFF CAPS CO NECTOR i >The Rubber Blow-Off Cap helps keep the orifice of the nozzle free of grease or other substances that could interfere with agent dis- tribution.A retaining strap attaches the blow-off cap to the nozzle. FIGURE 18 Rubber Blow-Off Caps must be ordered as a Shipping Assembly, 0001553 >Part No. 77695, which contains 50 blow-off caps, or Part No. >77411,which contains 12 blow-off caps. "QUIK SEA "ADAPTOR The"Q ik-S'al"adaptor is a listed mechanical bulkhead fitting that produc6s a 'liquid-tight seal around both distribution piping and `�• detecti§n conduit which runs through restaurant hoods and ducts. The "Quik-seal" adaptor accepts threaded pipe or conduit. The >adaptor is available for 1/4 in. (Part No. 78196), 3/8 in. (Part No. >77285) 1/2 n.(Part No.77287),or 3/4 in.(Part No.77289)pipe or conduit size When using with EMT conduit, a conduit connector must b in talled in each end of the adaptor. The "Quik-Seal" Adapto Shi ,ping Assembly must be ordered as stated below: FIGURE 16 Shipping 00000, Assembly Hole Size Size j Part No, qty. Required CB METAL BLOW-OFF CAP 1/4 in. I 78196 24 3/4 in. The CB Metal Blow-off Cap Package, Part No.433208,is used for 3/8 in. 77285 24 1 1/8 in. all high temperature environments.The metal blow-off cap con- 1/2 in. 77287 24 1 1/8 in. tains a special O-ring placed inside the cap which integrates with 3/4 in. 77289 24 1 3/8 in. the nozzle to create a seal and to help hold the blow-off cap in > position. ADAPTOR BODY The CB Metal Blow-Off Cap Package, Part No.433208, contains cz::�GASKET 10 blowoff caps. LOCKWASHER Also available is a 10 pack of CB Stainless Steel Blow-Off Caps, Part No.434707. NUT i >A 10 pack of Metal Blow-Off Cap O-rings, Part No.551530, is also > FIGURE 19 >available. 0001U STAINLESS —� STEEL WIRE METAL CAP FIGURE 17 007633 SECTION III—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-7 7-1-09 REV.6 "COMPRESSION-SEAL"ADAPTOR D COCKING LEVER/LOCK BAR This adaptor is a mechanical bulkhead fitting that produces a The cocking lever is a component required to cock(arm) both the liquid-tight seal around pipe and conduit when installing distribu- mechanical/electrical ANSUL AUTOMAN release and the mech- tion piping and detection conduit through restaurant hoods and anical gas valve.After the ANSUL AUTOMAN is cocked (armed), ducts. The "Compression-Seal" adaptor is a straight-through the lock bar must,be inserted to eliminate the accidental firing of design requiring no cutting or threading of conduit or pipe.The the release mechanism.These components are available as either e adaptor is available for pipe sizes of 1/4 in.(Part No.79149),3/8 in. an individual shipping assembly ora shipping assembly containing (Part No.79151),1/2 in.(Part No.79147),and EMT conduit size of both. Listed below are the various shipping assembly part num- 1/2 in. (Part No. 79153). Each "Compression-Seal" Adaptor bers. Shipping Assembly must be ordered as stated below: Part No. Description Shipping Assembly Hole Size 435603 Short Handle Cocking Lever only Size Part No. Qty. Required (MechanicaVElectrical ANSUL AUTOMAN) 1/4 in.Pipe/1/2 in.tube 79149 24, 3/4 in. 435790 Short Handle Cocking Lever with Lock Bar 3/8 in.Pipe/5/8 in.tube 79151 24 1 1/8 in. (Mechanical/Electrical ANSUL AUTOMAN) 1/2 in. Pipe 79147 24 1 1/8 in. 14995 Long Handle Cocking Lever only 1/2 in.EMT Conduit 79153 24 1 1/8 in. (Mechanical/Electrical ANSUL AUTOMAN) 15618 Long Handle Cocking Lever with Lock Bar COMPRESSION NUT (Mechanical/Electrical ANSUL AUTOMAN) 26310 Cocking Lever only(ANSUL AUTOMAN II-C) ADAPTOR BODY 416018 Cocking Lever only(Mechanical Gas Valve) GASKET LOCKWASHER NUT-® 14985 Lock Bar FIGURE 20 Short Handle Cocking Lever 000155 "HOOD SEAL"ADAPTOR ASSEMBLY This adaptor is a mechanical bulkhead fitting that produces a liq- uid-tight seal around 1/2 in.EMT conduit when installing the detec- tion line through restaurant hoods and duct.The adaptor accepts a high temperature pulley elbow and, when used, correctly posi- tions the elbow or conduit in line with the conduit adaptor hole in the detector bracket.The"Hood Seal"eliminates the need for mul- tiple elbows when penetrating the top of a hood when installing the 'Requires a crescent wrench or open and/box wrench detection line."Hood Seal"Adaptors are available in quantities of 6 as Shipping Assembly Part No.423253. Long Handle Cocking Lever /SEAL NUT SEAL G WASHER ADAPTOR BODY--= O GASKET PULLEY O ELBOW \ (NOT PART �l OF ASSEMBLY) Lock Bar USE ONLY PULLEY ELBOW,PART NO.423250 FIGURE 21 000150 D REDUCING COUPLING The reducing coupling,Part No.436228,is made of stainless steel material with 3/8 in.x 1/2 in. NPT inlet threads. If necessary,the reducing coupling can be utilized when installing the Agent FIGURE 23 Distribution Hose Line Kit, Part No. 435982. Two couplings are 005325 required per Agent Distribution Hose. 114 IN. (3.3 cm) 1 3/16 IN. (3.0 cm) FIGURE 22 000324 SECTION III—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-8 REV 8 7-1-09 DETECTORS PULLEYTEE The detector consists of three basic components:the bracket,link- The Pulley Tee(Part No.427929) is used to change the direction age, and fusible link.(Fusible links are not included and must be of two wire ropes by 900.It must be used in areas where the tem- ordered separately.)The bracket holds the entire assembly to the peratures are within the range of 32°F to 130°F(0°C to 54°C). mounting surface.The linkage is used to support the fusible link. Pulley tees can be used in mechanical gas valve actuation lines The fusible link is designed to separate at a specific temperature and remote manual pull station lines. Pulley tees cannot be used and release the wire rope,thereby actuating the regulated release within a detection line. mechanism. The scissor style detector allows the wire rope to be strung com- pletely through the detection system conduit and brackets first and O O the detector linkage assemblies are then clipped on later. The detector consists of two types of assemblies: P The Terminal Detector(Part No.435546)includes a test link and is placed last in a series of detectors.This detector is sometimes a referred to as the end-of-line detector and is thus named because FIGURE 26 it is at the point at which the wire rope"terminates;'or is anchored 000447 at the detector bracket.Only one terminal detector is required per STAINLESS STEEL CABLE detection system. Te in.stainless stecale is run from the D The Series Detector(Part No.435547)is any detector located in- hh ughc conduit, all ser es detectors and pul eytelbows, and erminal into line between the regulated release assembly and the terminal the regulated release mechanism trip lever.When any fusible link detector. separates, the tension on the cable is relaxed, and the trip lever D When using Part No.435546 and 435547 detectors, a total of.15 actuates the regulated release mechanism.The cable can also be detectors can be in one detection system:14 series detectors,Part used for mechanical gas valves and remote manual pull stations. •No.435547 and 1 terminal detector, Part No.435546. The cable is available in 50 ft (15 m) (Part No. 15821) and 500 ft •Note: Series Detector, Part No.435547, is also available as Part (152.4 m) (Part No.79653) lengths. P No,435548,25/Pkg. SCISSOR STYLE-PART NO.435546 AND 435547 BRACKET LINKAGE FUSIBLE V LINK FIGURE 24 000159 PULLEY ELBOWS There are two types of pulley elbows used to change the direction of the wire rope by 900.ANSUL recommends for temperatures not in excess of 700 °F (371 °C). Part No. 415670 has socket ends with set screws for 1/2 in,conduit, and Part No.423250 has com- pression ring ends also for 1/2 in.conduit. Pulley elbows must be ordered in quantities of 50 as Shipping Assembly Part No.415671 (socket end type)and Part No.423251 (compression end type). PART NO.415670 PART NO.423250 O D 000160 000161 FIGURE 25 I SECTION III-SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-9 7-1-09 REV.5 REMOTE MANUAL PULL STATION MECHANICAL GAS VALVES The remote manual pull station (Part No. 434618.or.435960) is The mechanical gas valves are designed to shut off the flow of gas made out of a molded red composite material. The red color to the appliances upon actuation of the regulated release assem- makes the pull station more readily identifiable as the manual bly.The valves are available in sizes of 3/4 in.,1 in., 1 1/4 in., 1 1/2 means for fire suppression system operation.The pull station is in.,and 2 in.ANSUL style;and 2 1/2 in.and 3 In.ASCO style.The compatible with the ANSUL Flexible Conduit.The molded manual valves are rated for natural and LP gas.Both styles are UL Listed pull station should be mounted at a point of egress and positioned 'and includes the air cylinder, tubing, and fittings, Part No. 15733, at a height determined by the authority having jurisdiction.Trim for connection to the release mechanism. Rings, Part No.427074(pack of 10), are available. Maximum Part No.434618(Without Wire Rope) Part Operating Part No.435960(With 50 ft(15.2 m)of Wire Rope) No. Description Pressure 55598 3/4 in.Gas Valve (ANSUL) 10 psi (0.69 bar) 55601 1 in.Gas Valve(ANSUL) 10 psi (0.69 bar) uw�p� 55604 1 1/4 in.Gas Valve(ANSUL) 10 psi (0.69 bar) 55607 1 1/2 in.Gas Valve(ANSUL) 10 psi (0.69 bar) 55610 2 in.Gas Valve (ANSUL) 10 psi (0.69 bar) 25937 2 1/2 in.Gas Valve(ASCO) 5 psi (0.35 bar) 25938 3 in.Gas Valve (ASCO) 5 psi (0.35 bar) Flow Capacity BTU/HR, at 11 in.P.D. (CFH) 0.64 SP GR FIGURE27Pipe Size P.D.1 in.WC 1000 BTU/ft3 (inches) 0.64 SP GR Natural Gas FLEXIBLE CONDUIT 3/4 751 751,000 Flexible conduit allows for quicker installations and the conve- 1 1288 1,288,000 nience of being able to route the cable over, under and around 1 1/4 1718 1,718,000 obstacles. Flexible conduit can.be used as a substitute for stan- 1 1/2 2630 2,630,000 dard EMT conduit or can be used with EMT conduit.Flexible con- 2 4616 4,616,000 duit can be used only with the Molded Manual Pull Station, Part 21/2 5700 5,800,000 No.434618, and mechanical gas valve installations.The Flexible 3 7100 7,300,000 Conduit comes in a 500 ft (152.4 m) length, Part No.434525, or To calculate gas flow for other than 1 Inch p.d.: together with 500 ft(152.4 m)of wire rope, Part No.435959. Also available is a Flexible Conduit Strain Relief (50-pack), Part New cfh=(cfh at 1 inch)x mew plc No.435979. To calculate gas flow for other than 0.64 SP GR: A 50-pack of Flexible Conduit Inserts, Part No. 434347, is also New cfh=(cfh at 0.64) x available. New SP GR P Note:Flexible conduit cannot be used in detection systems. A B C Valve Size in. (mm) in. (mm) in. (mm) 3/4 in. 33/4 (95.3) 63/8 (161.9) 51/2 (139.7) 1 in. 33/4 (95.3) 6 318 (161.9) 51/2 (139.7) 1 1/4 in. 47/8 (123.8) 73/8 (187.3) 63/8 (161.9) 1 1/2 in. 47/8 (123.8) 73/8 (187.3) 63/8 (161.9) 2 in. 57/8 (149.2) 77/8 (200.0) 611/16 (169.9) 2 1/2 in. 713/16 (198.4) ----- 91/16 (230.2) 3 in. 725/32 (197.6) ----- 91116 (230.2) D. c C - B �A � 314 IN.THRU 2 IN. 2 1/2 IN.THRU 3 IN. 004208 004209 FIGURE 28 SECTION III-SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-10 REV.4 7-1-09 ELECTRICAL GAS VALVES MANUAL RESET RELAY The electrical gas valves are designed to shut off the flow of either The Manual Reset Relay, Part No.426151, is required when using natural or LP gas to the appliances upon actuation of the regulat- an electrical gas valve shut-off system.After the electric gas valve ed release assembly.The valves are available in sizes of 3/4 in., has closed, either due to system actuation or power failure, the 1 in., 1 1/4 in., 1 1/2 in.,2 in., 2 1/2 in.,and 3 in.The valve is held valve cannot be re-opened, allowing gas to flow, until the reset open by an energized solenoid and upon system actuation, the relay button is manually pressed, re-energizing the circuit. The switch contacts in the regulated release assembly open, thus de- reset relay is available 120 VAC.The manual reset relay is also energizing the circuit to the gas valve solenoid, causing the valve recommended for electrical shut down.' to close.Valves are available in 120 VAC and are UL Listed. Part Max.Operating No. Description Pressure 13707 3/4 in.Solenoid Gas Valve (ASCO) 25 psi (1.7 bar) 13708 1 in.Solenoid Gas Valve (ASCO) 25 psi (1.7 bar) 550360 1 1/4 in.Solenoid Gas Valve (ASCO) 25 psi(1.7 bar) 13709 1 1/2 in.Solenoid Gas Valve(ASCO) 25 psi(1.7 bar) 13710 2 in.Solenoid Gas Valve(ASCO) 25 psi(1.7 bar) 550363 21/2 in.Solenoid Gas Valve(ASCO) 5 psi(0.35 bar) D 17643 3 in.Solenoid Gas Valve(ASCO) 5 psi (0.35 bar) Flow Capacity BTU/HR, at 1 in.P.D. FIGURE 30 (CFH) 0.64 SP GR 000007 Pipe Size RD. 1 in.WC 1000 BTU/ft3 (inches) 0.64 SP GR Natural Gas ELECTRICAL SWITCHES 3/4 264.96 247,500 The electrical switches are intended for use with electric gas 1 1091.01 1,119,000 valves, alarms, contactors, lights, contractor supplied electric 1 1/4 1662.49 1,730,000 power shut-off devices and other electrical devices that are 1 1/2 1818.35 1,900,000 designed to shut off or turn on when the system is actuated. 2 3117.18 3,251,000 Switches are available in kits: One Switch Kit, Part No. 423878, 21/2 6078.49 5,821,000 Two Switch Kit, Part No. 423879, T*e Switch Kit, Part No. 3 7169.51 7,430,000 . 423880,and Four Switch Kit,Part No.423881.Mounting hardware To calculate gas flow for other than 1 inch p.d.: and 12 in. (305 mm) long wire leads are provided with each kit. Each switch has a set of single-pole, double-throw contacts rated New cfh=(cfh at 1 inch) x f"new p:d. at: To calculate gas flow for other than 0.64 SP GR: UL/cUL/CSA Rating ENEC Rating New cfh=(cfh at 0.64)x /_0.64 --- 250 VAC, 21A Resistive IE4T105p Approved e New SP GR 250 VAC, 2 HP 250V, 21A Resistive 125 VAC, 1 HP 8A Motor Load Valve A i3 Size in. (mm) in. (mm) COMMON NA 3/4 in. 35/16 (81.0) 3 5/8 (92.1) 1 in. 5 (127.0) 627/32 (173,8) 1 1/4 in. 713/16 (198.4) 729/32 (200,8) 0 0 1 1/2 in. 5 (127.0) 519/32 (142.1) N.C. 2 in. 63/32 (78.6) 515/16 (150.8) 2 1/2 in. 713/16 (198.4) 729/32 (200.8) 3 in. 713/16 (198.4) 729/32 (200.8) Q ° FIGURE 31 001612 B -F- �-----A �1 FIGURE 29 004210 SECTION III—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-11 7-1-09 REV. 1 ALARM INITIATING SWITCH ML STYLE Fusible Link To Be Used The Alarm Initiating Switch Kit, Part No. 428311, can be field Fusible Shipping Where mounted within the ANSUL,AUTOMAN release.This switch must Link Assembly Temperature Temperature be used to close a supervised alarm circuit to the building main fire Part No. Part No. Rating Does Not Exceed alarm panel when the ANSUL AUTOMAN release actuates.This 550368(.1) 551522(10) 165 OF (74°C) 100'F (38°C) action will signal the fire alarm panel that there was a system actu- 550365(l) 551523 (10.) 212'F(100 OC) 150'F (66 OC) ation in the kitchen area. The switch kit contains all necessary 550366(l) 551524(10) 280'F(138 OC) 225'F(107 OC) mounting components along with a mounting instruction sheet, 550009 (j) 551525(10) 360'F(182 OC) 290'F(143 OC) The switch is rated 50 mA, 28 VDC. 550367 (l) 551526 (10) 450°F(232°C) 360 OF(182 OC) SPACER 56816 (l) 551527 (10) 500'F(260 OC) 400 OF(204°C) TOWARD ANSUL WHEN SPACER AND 56816 (l) 73867(25) 500'F(260°C) 400'F (204 OC) AUTOMAN� SWITCH ARE PROPERLY MOUNTED,THIS DIVIDER MUST BE BETWEEN THE � N.O.AND N.C.TERMINALS \ COM ANSUL. Z N.O. TEMPERATURE RATING STAMPED ON FUSIBLE LINK BODY r N.C. K STYLE ML STYLE / > 000170 000171 FIGURE 34 ALARM INITIATING SWITCH MAXIMUM REGISTERING THERMOMETER FIGURE 32 004990 >The Maximum Registering Thermometer, Part No.15240, may be used to indicate the highest normal temperature for the protected REGULATOR TEST KIT area.Once this is established,the correct rated fusible link can be -- The Test Kit Assembly(Shipping Part No.56972)is required to test 'chosen. Other methods for determining maximum temperatures the regulator setting and nitrogen flow during 12-year maintenance >may be used. examinations. This will ensure that the regulator is functioning HOSE/GROMMET PACKAGE properly. The Hose/Grommet Package,Part No.418511,consists of a 24 in. ® rubber hose and 2(two)grommets.This package is required when expellant gas hose is routed outside the ANSUL AUTOMAN Regulated Release, Regulated Actuator, and/or tank enclosure assemblies. FIGURE 33 000169 FUSIBLE LINK Select correct UL Listed fusible link(s)for installation in detector(s) according to the temperature condition chart below: K STYLE Fusible Link To Be Used Fusible Shipping Where Link Assembly Temperature Temperature Part No. Part No. Rating Does Not Exceed 415739 (l) 415739(l) 165 'F (74°C) 100'F (38 OC) 415740 (l) 415740(1) 212 OF(100 OC) 150'F (66 OC) 415741 (1) 415744(25) 280 OF (138 OC) 225 OF(107 OC) 415742(l) 415745 (25) 360'F (182 OC) 290'F(143 OC) 415743(1) 415746 (25) 450 OF (232 OC) 360'F(182°C) SECTION III–SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-12 REV. 1 7-1-09 IN-LINE BURST DISC ASSEMBLY(MANIFOLDED SYSTEMS NOZZLE AIMING DEVICE ONLY) The Nozzle Aiming Device, Part No.431992, is available to prop- The in-line burst disc assembly is required to eliminate the siphon- erly aim each nozzle to the correct aiming point. The device ing of the agent up the pipe during extreme temperature variations. clamps to the nozzle and emits a small laser light that reflects on In addition to eliminating the siphoning effect,the common in-line the surface that it is aiming at.The nozzle can then be rotated to burst disc assembly eliminates the possibility of one or more indi- point at a predetermined aiming point and then tightened to hold vidual discs located in the tank adaptor from failing to burst.The that angle.The aiming device adaptor attaches to the nozzle.The assembly consists of a stainless steel body which houses the shipping assembly consists of the aiming device and the adaptor. burst disc.When utilizing this assembly in a manifolded system,it is necessary to modify(remove)the burst disc located in all of the R-102 tank adaptors in the system.The in-line burst disc assem- bly Is to be mounted as close to the tank outlet as possible.After system discharge,the assembly must be disassembled and a new burst disc installed. Part No. Description ADAPTOR 416970 In-Line Burst Disc Assembl NOZZLE y AIMING 417911 Burst Disc(Pack of 10) DevlcE FIGURE 37 _— 1.54 IN. ,—,�I 000520 ! (3.9 cm) STAINLESS STEEL BRAIDED ACTUATION HOSE The Stainless Steel Actuation Hose is used to connect the actua- tion line compression tees between each pneumatic actuator.The hose has the same thread, 7/16-20, as the fittings.The actuation hose allows flexibility between the AUTOMAN and each regulated actuator. Hose Part No. Length Couplings 31809 16 in.(41 cm) 7/16-20 x 7/16-20 Females 32335 20 in.(51 cm) 7/1,6-20 x 7/16-20 Females --� 32336 24 in.(61 cm) 7/16-20 x 7/16-20 Females 430815 ti�.� \\\\�,�• h,�,,,," 42 in.(107 cm) 7/16-20 Female x 1/4 in. NPT Fitting Part No. Description RED SIDE OF BURST / DISC TO BE TOWARDS—� 31810 Male Elbow(7/16-20 x 1/4 in.NPT) ADAPTOR,PART NO. 31811 Male Tee(7/16-20 x 7/16-20.x 1/4 in.NPT) 417707 415371 Tee(7/16-20 x 1/8 in.Male NPT x 1/8 in.Female NPT) FIGURE083833532338 Male Straight Connector(7/16-20 x 1/4 in.NPT) 25627 1/4 in.Check Valve 1/4 IN.CHECK VALVE The 1/4 in.check valve, Part No.25627, blocks the flow of actua- tion gas from the actuator that was actuated to the actuator(s)that was not actuated.This prevents actuation gas from escaping from Ins-2o 7116-20 an open actuator which may have had the cartridge removed. , FIGURE 38 CHECK VALVE PART NO.25627 000433 D AGENT DISTRIBUTION HOSE AND RESTRAINING CABLE KIT The Agent Distribution Hose and Restraining Cable Kit, Part No. 435982,consists of a 5 ft(1.5 m) long Agent Distribution Hose, a 3 ft (0.9 m) long Restraining Cable, and a Restraining Cable Hardware Package.The Agent Distribution Hose can be utilized with castered cooking appliances with;castered supports found in commercial kitchens.The hose allows I for movement of the appli- (0. IN.NPT6 cm) 2 IN. ance for cleaning without having to disconnect any fire suppres- (0. (5.1 0m) sion system discharge piping. Note:The Agent Distribution Hose Is authorized for use with only D FIGURE 36 UL Listed ANSUL Wet Chemical Restaurant Fire Suppression Systems. -� 000899 5 REVISIONS D SPFCTFICATInN; APTRAT R Ac-TOP�SOLO FILTER A PATENT NUMBERS FOR QUESTIONS,CALL THE PC-PSP O➢RITED STAICS)-US PATENT 7963330 B2. TME RATE EASE-STOP SOLO F0.TCR N I S A SL STAGE RE- RAT1AInG Long IYvW OGike AC-PSP WALL(CANAM)-CA PATENT 2820%9. A UNICUE S-BAFFLE DESIGN IN COMUNCTIDN VIIH A SLOTTED REAR BAFRC DESIGN. 0 RN101 43 AC-PSP iN AN➢(CAVA➢A)-G PATENT 2528136 TO IICLIW R EKCEPTIOIAL FILTRATION EFFICIENCY. PHOS(516)513-5398 [KHAUSi 0003 NO-2/BO-2/SND-2(CANAIW-CA PATENT 2]20135 C. FILTER li STAINLESS STEEL LOTSTRIILTION.AM SQC➢TO FIT INTO STAN➢A¢D EMAIL re0433econe0'.[on 2-INCH DEEP NE00 CINNVELI . UNITS SMALL INLWIE STAINLESS STECL BANDIES A.A FASTENING➢[VICE TO SECURE THE TWO M 0 - A 04 KWN)ST TOTAL GOO CO.,G COMPONENTS WHEN ASSEMBLED HNOD TAG l00EL OF SP RLENGTN COOKING TYPE APPLIANCE DESIGN TOTAL S ( SUPPLY CO)ST�WICDTION END TO RCW G¢EASE EXIRACTI@J EFitLIENLY PERFORMANCE 511ALL REMOVE AT LAST I.OF GREASE 0 TEMP BUTY CFN/TT EYN—ANDTH IENG IGNT DIA 3 CFM VEL SP 6N ENO FTIRES FIWE HICRONS IN S12E.ANO DS.GR[7SE PARTICLES SEVEN M[ERl¢1S IN 512E AND E 430 SS LARGER.WITH A CDR¢ESPON➢tNG PRESSURE IRDP NOT 10 EXCEED LO W[MES OF WATER GAUGE. - E 1 4.22 ECOJ-PIR 12'9' CEG I )CAVY 275 3506 10' 33' 4' 3506 1520 -IR25' 2801 WHERE EXPILSED THE CAPTRRTE GIEASE-STOP SGLO WAS TESTED LO ASTM$TAN➢ARD AS F2519-OS 130 SS MANUG'.1 RER APPROVED FOR USC W SOLID NR.'ICATIBNS AS AS AR¢ESTER g E FfFiC10KY vi PAartd[O[AI¢'itR PIiESs,PC ORO•vS MV NATE 2 MIS126 ECON'U'I 4'11' ➢EG I N/A 0 0 1102 WHERE CJ�CSN ALRVE ALONE B 130 SS 3 126 EC E, 4.11' DEG I WA 0 0 1402 WHERE C%POSEO ALONE - XISL-Piv D 00 FO N , nelxE L cia[A W i[H `ST[ 1� IDT�pD TAG TTp[ OiYFMITGHESLENGTN EFF M,[�ONSP> LTTVE ) MFE LOCATIIN SXL TTpE F T SIZE T( MUCEL A OUANT6Y PIPING WEIGHT ; u. 85%SEC fILTEa iY %J • 1 tPPTRATE SQD GDTER '9 20' 16 SPEC 4 L55 SERIES E26 M37 RIGHT 12'N4B'N21' LPS LB v e C 2 0 4S AD C�B.t PAa,30.CuDLV[1C2.aN) RLW GTE 1610 A 0 ® m 3 WTGTE FILTERS ARE MILT IN[OIRW+N VITNu ® ^ O C e NGYA 096 `7l�eulUAl1�V\j/,\' SG STANDARD tt O z HOD TAG OPTION UL STANBNtD 41016. i INC. NOE 1 DACKSPLALVI IW.00' NIGH % 16500' LONG 430 IS VERTICAL ULC-36495641 � C F SENSOR-Cv. , ^ F L f ¢ ) I HOOD TAG POS [NGT WIDTH MIEIGNt TYPE WIDTH LEND EM'S 6M Sv € ND 2 front L 59'N 12" 6' MUA 8' 36' 600 0.139' 3 front 59' 12" 6' NW 8' 36' 600 6139' Z (U i o U T IULL N W S11PRY PtEMa1 cu N]OD CRVER OU¢OVOR�C Di I�NSTALL.Ca) aAnWa�aE RTD SENSOR INSTALLATION (IF NOT FACTORY INSTALLED) Z - nN¢DVARC'��er Ws1iaLElb �u,w� o + NICD Ore RI[,B M1ss`]�.Im`°MIDI(ar4ct b cmlyd c°bet • ru...vu U s u U 4{ 41 ...A. NM.I.U nao U �-I f A/l Mrwm,v�) t �r u�� aa� DATE,3/31/3042 kY9� n11.w DriOS 51GA p�EM_6-I Y INSTRUCTIONS ASSEMBLY INSTRULTiONS DRArie1 n6rk.eY6n ED pccrMBLY INSTRUCTIONS HANGING ANGLE RUST BE SUPPORTED VITH 1I2'-13 TPI WwGING ANGLE MUST BCSWPDRTEO VITN 12'-13 TPI RY: mK.is®Fi°'O GRADE 5(MINIMUM)ALL-TWEA0.SANDWICH WINGING GRADES(MINIMUM)ALL-THREAD.SANDWICH WNGSNG HANGING ANGLE MUST BE SI.EPORTEO VITH I/2'-13 T" ANG1.E2 AND CEILING PNCHOR POINTS WITH 1/2'DRAOE 5 SAD CEILING ANCTIOR POINTS VITH 12'GRADE 5 $OAL6 (MINIMUM)STEEL FLAT WASHERS AND 1/2'-13 TPI _ GRADE 5(NIMMIM ALL-THREAD SANDVICII HPNGING MINIMUM)STEEL FIAT WASHERS ANO 1/2'-13 TPI GRADE 5 011NIMUM)IE%NUTS AS SHOWN.HEST USE ANGLES ANO CEILING ANCHOR POINTS VITH 1/2'GRADE 5 GRADE 5 GAINUMN HEX NUTS AS SHOYN.MUST USE DOI)BLED HIX NUT CONFIGURATION ABOVE CEILING WIMMVN)STEEL FLAT WASHERS ANO I/2' UD ED HEX NUT CO,SIGIIRATION ABOVE CEILING ANLHMS SINGLE HIX MIT BENEATH HANGING ANGLE IS MASTER Df1AVNNG GRADE 5(MINDOIM)HIX NUTS AS SHOWN.MUST USE ANCHORS SINGLE NIX MIT BENEATH HAILING ANGLE IS ANEPTAHLE GOR PSP HANGING ANGLES.MAINTAIN 1/<'OF ltrm m 0.®1BI ,IE%MIT CON-i IGURATIS BENEATH HOOD HANGING pLCEPTABLE GTIR GLiL LENGTH HANGING ANGLES EXPOSED THREADS BENEATH BOTTOM 11EX 1¢IT•TORWE ANGLES AND ABOVE CEILING ANCHIIRS.WNNTAIN 1/4'OF MAINTAIN 1/4.OF EID'OSED UTS TO BENEATH BOTTOM ALL NEI NUTS TO 57 FT-LDS EXPOSED THREADS BENEATH BOTTOM MES NUT.TORQUE HEX NWT.TOROIE ALL NE%MJTS TO 57 R-LBS. ALL HET HITS TO BT FT-LBS. SHEET NO. t r E + REVISIONS D A T—� SEC TEMP�� E -SER DETAIL S .uwv�uA+wu R'v+o�nr omm .mm...umTm ' DR PL4N NEW-HOOD F2 NEW-NOOp 83 O 4' 11.00 LONG/26M150-PSPPLAN _ 6MIS0-PSP 1 1]�Q Gnn�sp�rw Xi®ns2 m "' NR[ MvirDput 12'aW LGtia+. i J � ✓� s rATm v1Tx imoc � Z (1J r maa.L n...ovr. O U p� W _ ru .xv orwrerxo�ii U C4 urx L Y ES O1 U Z Y i� BAo�Aw�xiw C$ ti U M: I DAT&-3/31/2022 DWGP. 5184904 sv�0 DRAWH —k— eV: SCALA mn3TER ORAwIxo TION L^PP/ I;ODPl,4824EX-2 fIDDD-of SHEET N0. 2 NEVISIONS Fy��Qj1 ON- O 51849 4 � UNIT TPG GTY FPN UNIT MODEL Y NPNUFACIURER VM CSP RPM "wE� HP 6HP PHASE VOLT fLA VIELOCITY 4� SOKS 1 1 E HDJ24HP cCCu-AIR 3506 I I.C. I 99] p➢P 12000 I1.5920I 1 1115 165 J9>fPX 264 I 21 MUA FAN INFOR6fATI0N-JOB S7H4904 FM' UNIT TAG DTY GPN UNIT NpDEL tl BLpVER HOUSING [Hil'M ➢� ESP RPM E� HP HHP PNPSE VOLT FLA NEA M➢fP n acl SONES NO I EA-PI-GLO 1 0 50 AI - 2605 0300 923 00P 7016 11H90 1 113 122 153P 29A 2fi0 21 8 FAN UNITTAG QTY ➢ESCRIPTRRI °u xp GREASE Bp% 1 2 M PARTS—1-IT 2 1 2 YEM PMTS VARRA F CC&SSORfd'S �° 1 TEM UNIT TAG • NO GREASE GRAVITY VPI.L SI➢E GRAVITY NOIpRI2Ei1 VALL CUP CAMPER NTAINT➢ISEHPRGE CAMPER MNPER MWNT YES p LL _U NO V[1fM ITEN -C FAV 1 0 1 4H LHS NRH 31500'V 31500'L%20AOD'H 4DOD1=PITCH�A-�MGK -NT- A[UNH 21D00 . J NI -1,L Mp Axo uc-ssti4 vm— S AIN uRnnEa waa -wEUE n].�csv¢A�iivr— 2n• a'2 20 GAUGE STEE euauL iDPpnTUS i¢] CONSTRIICTIDN. L FAN P— DFT610RAipG(TRLIS�Vf cEtLFTD tx _ 3 FLANGE. �� E0.SE GRAIN VOULv Vu3[viaATE OP[RAT.TAN ` L _nAT TE ra+1-1 � RG➢F CIPMING 6R[Att vuN1vS 3I `✓ ➢IMENSIpNi 2 ——— aw ieaRwz vvxTilw iwi Cmv crux PIT66:➢C RS ARE AVAIr em f�1' uua® �S FOR PITENEO -- B R KAA i VARRAxtt. SPECIFY PITCH 12' EXAMPLE 7/12 PITCH=30'SLOPE pILTVIT HETVCEN Nlp PN I. oiH�ERS]Dll • L_ �l w...w n (1J U U ..�..r..o W ru �p� 0 Z O }� ---- U Y L U Y 4' ice' d c5 U F I I DATE 3/31/2022 imm— DMA 5184904 TOP VIEW D"Aay xnf1-- SCALA --"""'®"6 ransrea oNAwIN� SHEET NO. 3 REVISIONS _ p p � p i p W,C�ivLRCp�SIv0.T�NRi vi"Iµi�M IY ObWOt M s1S.1 Hprstx4 , Y�.H�2��f N R161i->IEGI. 6�,T A x,�,.,,�ELL,RAE okiiRx Ax"_�HRarrswwE aAa,E�Re ADLR Dries,,,<L,•„�:I�,a�FR�T.i,:1M EF,T�,„�,� S�cTS�p�plp¢�perssva[�""am�IAmnmr.vp°Eo"Mss"Eevew�xrc�n¢[ceu q[mm Mum vAv.GA¢uR E EE 3 8 ort BLOYER DMCHARGE L mp b I� tee• � � - a FLEIt = CGNOULT RIR GiELa vIRInTi � J z,yr Tb vz � 3 1 y�g F L6TING LUG. Koo $ ARROV. 4 S[@WECT BLUVER/SiD,OR - ACCESS I— N•SER 1. U. T - -- - L R HELREo � _ _ J• �" cu N U p W N P1TCHEa alias A¢Avanael[ 4• a r FGR ITT_ROOFS z H. 0 + SPECIFY PIICM U N E"AMPLE,7/12 PITCH=W SLOPE S- u d N U Y ' 0) 0- i-' o a U 2: DATE:3/31/2022 DWGX: 5184904 DMR nrk.ev _ BT: SCALE: -, - 3/4' 1'-0. MASTER OpAWIN6 SHEET NO. 4 s Ci IL M-t 02 SYSTEM X NEW EXISTING SIR-Eill III Lu �� FRONT VIEW SCALE 1/4" /^+ GAS VALVE _X_NEW EXISTING LEGEND 1?fTI, 'L- 1 .5GAL 1 3GALG=MECHANICAL GAS SHUT OFF VALVE Dftll�llYN BY._i4Nl�RE�1 B RCL___05 2022 P=REMOTE MANUAL PULL STATION PIPING MATERIAL BLACK MS=MICRO SWITCH fZE1(ISION#106/07/2022 SUPPLY PIPE SIZE 3/8" BRANCH PIPE SIZE 3/8" THIS INDICATES 3/8" SCHEDULE 40 BLACK PIPE GAS VALVE TYPE MECH SIZE 2" BRAND ANSUL THIS INDICATES'/2' 2-360 DEGREE SCHEDULE 40 BLACK PIPE DETECTOR TEMPERATURE RATING 3-450 DEGREE QTY 5 THIS INDICATES HOOD SIZE: 12'8"X 48"X 24" DUCT SIZE: 21 X 10 STAINLESS STEEL CABLERUN IN%"EMT CONDUIT HOOD SIZE: DUCT SIZE: FLOW POINTS 13 EQUIPMENT NOZZLE SURFACE NOZZLES QTY AREA PART# HEIGHTS LOCATIONS DUCT 1 21"X 10" 2W 0-50 CENTERLINE DUCT 'ANSUL AUTOMAN•REGULATED RELEASE" OPENNG ASSEMBLY(MECHANICAL) 21'•x10" IN HOOD CABINET PLENUM 2 12'9"X 48" IN 10-X4- 2"OFF FILTER ---------------------------------------------------- ---------------------------------------------------------- --------------- PLENUM zW ANYWHERE ALONG OR WITHIN PERIMETER OF ------450 ----- 360 - 360 --------- 50 ----I`-4 50-t ----------- FRYER 1 14"X 21 ' 3N FRONT HAVE OF POT AIMED 3 25"X 35" AT CENTER 1 N 1 N GJJA MS AFRONT EDGE AIMED L 6 BURNER RANGE 3 36"X 32 1/4" 1 F 40"X 50" AT CENTER 3N \ SMALL GRIDDLE 1N 1F 1F 1F 1N ANSUL 701 30 CI DOUBLE 1N SALVMANDfR TANK SMALL GRIDDLE PO 1/4•x 213)16' PUL --- COMBI OVEN LARGE GRIDDLE STATION WOKS 68 TABLE TO' CHARBROILER TANDOORI RANGE TABLETOP F15" ' 36"X 321/4' 24"X 28" R X TANDOORI 1 12"RO N 1 N 24"X 48" CENTERLINE 12"ROUND E15 GAS OPENING VALVE ALONG OR WITHIN R GAS/ELEC RAD 1 24"X 28" IN 15"X 40" PERIMETER AIMED AT IS ACCESSIBLE CENTER 14111 TAP[ FLOOl1 NATURAUMES ��sen FLOOl1 ENGINEER SALYMANDER 1 30 1/4"X 21 3/16" 1 N Z9'X 16"ABOVE THE GRATE AT � THE FRONT EDGE CONVEYOR FLOOR PLAN OVEN PAQTS X FRYER TO HAVE LIMIT CONTROL TO SHUT OFF FUEL AT 425 DEGREE REGULATED RELEASE ASSEMBLY(MECH)_#429853 x DETECTORS SHALL BE LOCATED OVERALL EQUIPTMENT SINGLE TANK INCLOSURE 1.5GAL=#429864 x SYSTEM INSTALLED AS PER UL300,MANUFACTURERS&AHJ SINGLE TANK INCLOSURE 3GAL=#429862 x MANUAL PULL LOCATED MAX 10'-20'FROM HOOD&48"FROM FLOOR 101-20 CARTRIDGE=#423441 X ALL FUEL SOURCES ARE GAS UNLESS OTHERWISE NOTED 101-30 CARTRIDGE=#423443 X THE FOLLOWING FUNCTIONS TO OPERATE UPON SYSTEM DISCHARGE DOUBLE TANK CARTRIDGE=#423493 *MAKE UP AIR SUPPLY SHUT DOWN*GAS FUEL SHUTS OFF IN KITCHEN 1W NOZZLE=#419336 *EXHAUST FAN REMAINS ON*ELECTRIC FUEL SHUT OFF UNDER HOOD IN NOZZLE=#419335 *FIRE ALARM SHALL ACTIVATE IF ONE IS INSTALLED 3N NOZZLE=#419338 2W NOZZLE=#419337 EXHAUST ii NOTE:' 230 NOZZLE_#419339 t ELEC. CCPR. TO SEE CAPTIVE-AIRE DWGS. 245 NOZZLE=#419340 O1 D ^'' FOR Kill REQUIRED FOR EXHAUST U)STQACT®V: 260 NOZZLE_#419341 HOOD. LOCATION: 290 NOZZLE=#419342 ABT DESIGN & FIRE PROTECTION 1 F NOZZLE=#4193333 AN , 1724 CHURCH STREET QUICK SEAL 3/8"_#77285 oia QUICK SEAL YZ"_#77287 O1A HOLBROOK, NY 11741 MARCOS CAFE PULLY ELBOW=#432250 140 PIKE STREET PULLY TEE=#427929 631-878-4896 FAX#631-878-5727 REMOTE PULL=#434618 - - NASSAU COUNTY LIC#406 MATTITUCK, NY 11952 1' n i� ANSUL MECH GAS VALVE t UP =#55601 �N• ��.y,. �' ` ' C� SUFFOLK COUNTY LIC# 111 1%"=#55604 11/2"= HUNTINGTON LIC#F016529 #55607 EMAIL:ABTF/RE@YAHOO.COMi #25937 I 3"_#25938 nki - L/� EMP. -- -- -- . LAV H. C. LAV. -- - --- �� 0 ;- - s-e- LAV. �-- * ra ; 19 21 (�C� 20'tJ - •.. 16 4b. 0152��` -- o JC - i'-� 2'-t0' r-N• r-1- IT. IJ 2A 22� 2 23 23a J ANS` — [Q-t (DO SYSTEM X NEW EXISTING FRONT VIEW SCALE 1/4" GAS VALVE _X_NEW EXISTING 1 .5GAL 1 3GAL _ G=MECHANICAL GAS SHUTOFF VALVE DRikVYI.1€iY: ANDREA BAYARD 05/11/2022 P=REMOTE MANUAL PULL STATION PIPING MATERIAL BLACK MS=MICRO SWITCH REVISION 0 106/07/2022 SUPPLY PIPE SIZE 3/8 BRANCH PIPE SIZE 3/8 REVISION#2 10/12/2022 THIS INDICATES 3/8" GAS VALVE TYPE MECH SIZE 2" BRAND ANSUL SCHEDULE 40 BLACK PIPE THIS INDICATES W 2-360 DEGREE SCHEDULE 40 BLACK PIPE DETECTOR TEMPERATURE RATING 2-450DEGREE QTY 4 _ THIS INDICATES i STAINLESS STEEL CABLE HOOD SIZE: 12 8 X 48 X 24-, DUCT SIZE: 21"X10" RUN IN Y2'EMT CONDUIT HOOD SIZE: DUCT SIZE: FLOW POINTS 12 EQUIPMENT NOZZLE SURFACE NOZZLES QTY AREA PART# HEIGHTS LOCATIONS DUCT 1 21"X 10" 2W 0-50 CENTERLINE DUCT "ANSUL AUTOMAN"REGULATED RELEASE" ODENING ASSEMBLY(MECHANICAL) 21"x 10" IN HOOD CABINET PLENUM 2 12'9"X 48" 1 N 10'X 4• 2••OFF FILTER -------------------------------------------- ----------------------------- PLENUM zw ANYWHERE ALONG OR WITHIN PERIMETER OF rl ------------3R, - 360 --------- 50 --- 450 -------------------- ----- -----' FRYER 1 14"X 21" 3N 25"X 35"FRONT HAVE OF POT AIMED 1N 3 AT CENTERS A G A FRONT EDGE AIMED L L r 6 BURNER RANGE 3 36"X 32 1/4" 1 F 40••X 50" AT CENTER 3N SMALL GRIDDLE N 1F 1F 1F 1N ANSUL CABINET hot-3o DOUBLE TANK SMALL GRIDDLE 011/a X213/16' PUL COMBI OVEN LARGE GRIDDLE STATION REFRIGERATOR 68 TABLE TOP CHARBROILER WOKS RANiE TABLETOP F15" 36"X 3:1/4" 24"X 28" R X 17 TANDOORI Y1s E GAS ALONG OR WITHIN R VALVEIS ACCESSIBLE GAS/ELEC RAD 1 24"X 28" 1 N 15"X40° PERIM TE ENTAIMER ED AT plPf=TAPE «OOR NATURAL/MES ENGINEER SALYMANDER 1 301/4"X 21 3/16" 1 N 29"X 16"ABOVE THE GRATE AT THE FRONT EDGE CONVEYOR FLOOR PLAN nvFN /.ACTS x FRYER TO HAVE LIMIT CONTROL TO SHUT OFF FUEL AT 425 DEGREE REGULATED RELEASE ASSEMBLY(MECH)_#429853 x DETECTORS SHALL BE LOCATED OVER ALL EQUIPTMENT SINGLE TANK INCLOSURE 1.5GAL=#429864 x SYSTEM INSTALLED AS PER UI-300,MANUFACTURERS&AHJ SINGLE TANK INCLOSURE 3GAL=#429862 x MANUAL PULL LOCATED MAX 10'-20'FROM HOOD&48"FROM FLOOR 101-20 CARTRIDGE_#423441 X ALL FUEL SOURCES ARE GAS UNLESS OTHERWISE NOTED 101-30 CARTRIDGE_#423443 X THE FOLLOWING FUNCTIONS TO OPERATE UPON SYSTEM DISCHARGE DOUBLE TANK CARTRIDGE_#423493 *MAKE UP AIR SUPPLY SHUT DOWN*GAS FUEL SHUTS OFF IN KITCHEN 1 W NOZZLE_#419336 *EXHAUST FAN REMAINS ON*ELECTRIC FUEL SHUT OFF UNDER HOOD 1 N NOZZLE_#419335 *FIRE ALARM SHALL ACTIVATE IF ONE IS INSTALLED 3N NOZZLE_#419338 2W NOZZLE_#419337 E1OiAUST 5000 NOTE. 230 NOZZLE_#419339 ti ELEC. M111 TO SEE CAPTIVE-ARE DWGS. 245 NOZZLE=#419340 OtD FOR WTERIN,%,�C REOUtRED FOR EXHAUST CON 6IT VACTo1p: 260 NOZZLE_#419341I Ham' LOCATION: 290 NOZZLE_#419342 I �• O7C ABT DESIGN & FIRE PROTECTION 1 F NOZZLE_#4193333 FAN , QUICK SEAL 3/8"_#77285 018 1724 CHURCH STREET QUICK SEAL W_#77287 HOLBROOK, NY 11741 MARCOS CAFE PULLY ELBOW=#432250 s-•• •- 140 PIKE STREET PULLY TEE_#427929 631-878-4896 FAX#631-878-5727 REMOTE PULL=#434618 — MATT►TUCK, NY 11952 ANSUL MECH GAS VALVE uQ NASSAU COUNTY LIC# 406 - 1"=#55601 ottT " !' SUFFOLK COUNTY LIC# 111 1 Y<"_#55604 _ f ,• i , ;1 . 1 Y2'_#55607 ii _ HUNTINGTON LIC#F016529 I ; : EMAIL: ABTFIRE@YAHOO.COM 2 2"=#55610 - - ���.' '/z"_#25937 3"_#25938 EMP. --------- ----- �� LAV _tzn H. C. �� __ !I/tii LAV. XL��LAV. � 161`07 c(3-ED y •' 23B ti !� • r ui o 00 5� `tL 00 om L(�ru `a= v c LL EXHAUST FAN MODEL: C j �L� 3Z0 ECON-AIR EABDU24HP �,� >I L_n4 m� 3506 CFM AS PER U.L. LISTING O cc , z 4_0 Li ro UP-BLAST GREASE EXHAUST FAN — MAKE—UP ARE MODEL: NOTE: 1 ECON-AIR EA-A1-G10 RETURN AIR MIN. 10' O POWER KILL SWITCH 2805 CFM AS PER U.L. LISTING FROM EXHAUST GREASE TRAP j 70 HINGE KIT (TYP.) t O W > II LIQUID TIGHT V ROOF CURB MAKE UP AIR DUCT WORK � I 18" MIN. pNEO R I I, C; O� L C.0I II z I I, >(TYP.) M16 O 00 V1 co RREMASTk;v 00 AS PER 21 x10 WELDED I I COMBUST r 16 GAUGE STEEL DUCT II 21"00" DUCT co TO HEAT SENSOR TEMP, PROBE ON ROOFUST FAN (2) PERFORATED SUPPLY PLENUMS I I IN BODY OF HOOD ON APPLIANCE + \•V = 0.. 4'-11"x12 x6" EACH SIDE OF FILTERS (TYP.) f HEAT SENSOR SHEETROCK CEILING F 3" WALL SPACER „ SHEETROCK CEILING U 7; N Z FAN -------� ANSUL CABINET ��� o N 0 N INTERLOCK N N �Ql 1. 12'-9" vE A " . ■ 1( J 11-0 3 SIDE WALL ECON-NR U.L. LISTED KiTCHEN GREASE HOOD 45 12 O Q Z 9 4824EX-2-PSP-F (SEE ATTACHED SUBMf1TAL) 48" o DOUBLE " SHEET ROCK o Z d- i ON METAL STUDS WITH GREASE BAFFLE FILTERS i U lu STAINLESS STEEL WALL30.25 FRYER 6"" GREASE CUP COVERING114 200Q SALAMANDER GUARD DOUBLE loo io HOOD OVER HANGS WITH STAINLESS STEEL WALL COVERING U COOKING EQUIPMENT 34" 36" 24" LU BY 6" MIN. ON ALL BACK WALL 34" UNAUTHORIZED ALTERATION OF, OR THE ADDIT►ON TO TANDOORI 6 BURNER CHAR- COMBI SIDES TANDOORI PLANS OR DOCUMENTS BEARING THE SEAL OF A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF OVEN RANGE BROILER ;n OVEN OVEN SECTION 7209, SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. FLOOR FLOOR ANY ALTERATION TO THIS DOCUMENT (MUST BE DONE BY A PERSON ACTING UNDER THE DIRECT SUPERVISION OF A LICENSED PROFESSIONAL IN ACCORDANCE WITH THE STATE EDUCATION LAW. FRONT VIEW CROSS SECTION COPIES OF THIS DOCUMENT NOT MARKED WITH AN ORIGINAL OF THE PROFESSIONAL ENGINEER'S INKED OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE •SCALE: %4" = 1'-0" SCALE: 4" = 1'-0" VALID TRUE COPIES. CLIENT: - X All views to the following scale 1/4 1 '-0'� X Dimensions KITCHEN CONSTRUCTION c1 X New Kitchen Existing Kitchen _ NON combustible (Masonary) _ Limited Comustoble-(S/rack—metal stud) � Combustable (S/Rock—wood studs) FIRE RAZED WAILS-2 NRS. _ Existing.1 hr. ok _ Special Sprinkler Installation-1 hr. ok X Marcos Cafe OPENING PROTECTIVE(I 1/2 HR)—(Self dosing, self latching, fire rated door assembly _ Special Sprinkler installation-3/4 hr. ok 140 Pike Street _ OK WTH4UT OPENING Protectives if ALL of the following comply - Mattituck, NY 11952 N Draft Curtain 24" HT.(NL/LC N Hds/Aes Special Sprinkler Installation N Exit at ade — OR — rimer heads within 24" of draft curtain 60" art kitchen safe X_'Cooiking Equipment In the Kitchen _ Cooking Equipment ct the front counter _ Cookingg Equi ment in the Dining Room _ Cooking Equipment in the r e on unit d) _ Cooking Equipment in a concess s and(d) _ Pizza Oven(d PROJECT: HOOD _ Exhaust cfm— Medium Duty (d) X Exhaust ch-'-Hee DLII d) _ Exhaust cfm--Extra Hea (d) INSTALL TYPE hat to griddle, fryers, pizza, rotisseries) (range, Wolk, gas elect. brollers) (Sold fud char broilers Wall—Linear Ft.x 340), (S—island Linear Ft x 540) Wdl—Linear Ft.x 400). (S—island Linear Ft x 600) (Wall—Linear Ft,x 550), (S—nand Unvr Ft x 700) KITCHEN HOOD X Liquid tight external weld _ 12max hood length per exhaust riser (d) X 18 ga. steel or 20 ga. stainless. X Supply Air 50/50-approx. replacement. (d) _ Supply Air 10 dg difference except A/C (d) _ Supply air hood damper (286 deg. max) Clearance 3" to Combustibles, Incd. 1" mineral wool. (Insul. the combustible not the hood $ Clearance 3`' to Limited Combustible (d) X Clearance— 0 to Non Combustible {{d) X Insulation — max Flame read Rating 25/x SKEET TITLE: CHAR BROILERS -- 4! min. to hood. _ Sand fuel to have spark arrestors (d) g FRYER— 16 Inch space to flame producing appliance or 16" high steel baffle, _ Solid Fuel— under separate hood HOOD PLAN FILTERS to heat source 18" minimum. To flue baffles f Inch minimum (uprights, rotisseries, ovens, etc) 6" overhang all sides. X 7 ft. maximum off floor. X 24 Inch minimum height dl sides LISTED HOOD installed in accordance With terms of its listing X Elect wire in conduit or EMT X Manufacturer ECON—AIR Exhaust CFM 3506 CFM U.L. LISTED R Clearance (Hood bottom to app. top) A Model 4824EX Supply ch 2805 CFM U.L. LISTED X Maximum booking surface temp. DUCTS X AIRFLOW 1540 ft/ minute minimum X Field welds #o be Bell or Td ing d Dimensions LxwkH X 16 go steel or 18 go Stainless �P g ( ) Duct exists Mg. ,redly as possible (d) X Horizontal duct fraud less them 75' (d) Duct connections to have flush bottoms (d) z Liquid tight external weld R No exhaust dam--ppens used Duct pitched back to hood to collect grease z O Ducts not shared by other systems X Shall not pass thru fire malls Not insulated unto inspected O Du _ CLEARANCE— Y minimum to combustibles, including 1 inch mineral wad, (hsvlate the combustible not thesiwd) Ln X CLEARANCE— Y to limited combustibles _ Clearance — V to non combustible (d) U X ACCESS PANELS — unobstructed X Within 3 ft each side of an inline fan _X Slgns— Access Panel — Do Nat Obstruct LU w ry {all d At floor vertically At direction of Ghon e 20 ft horizon vim► g R Access doer at horizontally cd base X Ductsecured to bldg,y EKTERRIOR — Weatherproofed _ ENCLOSURES — In bldg. more than 1 floor, from ding above hood or through any concealed spoc M ducts shall be enclosed. LU N Penetrate floors and ceilings N 6 inches duct to ardosure N Vented curb at roof d X Through Penetration Fire Stop System as alternative to Endosures with 6 inch airspace shall have a minimum 30 Inclusive airspace, depending on mfg. d O z FAN X TERMINATES — at bulding exterior up and away from roof X 40 inches from roof SHEET NO: Fan hinges away from duct with hold open retainer & flexible waterproof cable R Grease drains back to trap at fan _ Minimum 10' to air Intakes, property lines, windows and door's or 3' vertical R Safe access area for servicing _ Non—Cmustible s'Hie wall fan -termination ok, no openings 10' horizontal, don 32" vertical up, except char—broilers to permitted (d) A y ' Charles J. Zahra 1830 Pike Street Mattituck, NY 11952 June 1, 2022 ,r Southold Town Clerk 53095 Main Road Southold, NY 11971 Re: 140 Pike Street, Mattituck, NY— Dist. 1000 Sec 141.00 Block 04.00 Lot 005.000 To Whom It May Concern: On May 24th, 2022 the property located at 140 Pike Street (See attached Tax Bill), Mattituck, NY 11952 was conveyed to 140 Pike Street LLC; Pat & Phil Marco, of Cutchogue, NY and Peter Marco, Cutchogue, NY. We are no longer responsible financially for this property. We are not responsible for building permits, rental permits or any other governing regulations regarding this property by-Southold Town. Thank you in advance for any consideration, you may show this information. Regards, CharYia CC: Building Department, Code enforcement, Tax Department. s S va.P6uTE 25-P.0, £3(JX 1 W9 �:C�La3xs D$.tlt� a'L ; AA�.. ° �..Af"�1E k 7 E. .�.. l M0N-1,'1U 4:00 ANN 7X)3:00 1'M --c,oviltqomT NY 11H71-649u I9.6 C'i: 'L3 NIt 1,2021.-NOVEMBER 30,202-1-`MXES 13ECOME A LIEN F]FXn'*.',ry.EER 3,2021 631-765-1803 FAX:631-7655-51 q ° t p.�,,[i, 'P`,• t Tag i 4, q�jw a� t a° IF THE WORD"ARREARS"IS PRINTED HERE SEE 5 t I`t �4 `�"I`YG1 aM, }` ` NOTICE OF ARREARS ON REVERSE SIDE. ♦ °? 'e =` .:_473889.141.-4-5 382 14 17444 .a. p ® p p o •s r 140 Pike St 0.09 318,304,995 I 3,178,551 �i�e.•t.%2,tiufaw�S&llm !'�Y9;��^",:;"rC'vMLlu,a`., 465 1 Prof. bldg. 6169."'"'"AUTO"5-DIGIT 11935 ��—^ ^— �'• " " °_ ° ' " ����I�II���I1�11��111�11' 'I'I'I�011��I��I�I��III'IIII11�'���I111 12/7/2021 1,800 6,100 Zahra Charles J Zahra Jean T PO Box 1137 Zahra, Charles J. Mattituck,NY 11952-0920 First Half: 17389 $4,422.48 9.2/1612020._ ASSESSED___VALUE ' RATIO. 100%OF FULL VALUE Second Half: 17389 $4,422:49 12!16/2020 6 100: . WHICH "0.88°, c�F lTs: ' 4693182 - -- -- - - LEVY DESCRIPTION LEVY% TAXABLE VALUE _ p� �r F q�� TAX AMOUNT TOTAL TAX AMOUNT Mattituck School 61.95% _ 6,100 923.550 . 1.50%: 5,633.66 Mattituck Library 1 4.43% 6;100 1, 66;023 . 1.10% 402:74 - A 66.38% 0 6,036.40 Suffolk County Tax 1.11% 6,100`. ., 16.620 0.00% 101.38 SC Community College 0.12°!0? "6;1.00 1.271, 0.000/0- i I _ - . � . 1.2306 112.18 Southold Town Tax 22.760/6 6,100 I- ",-3392-9A- 2.20% 2,069:27. A 6. 22.760 9.27 MTA Payroll Tax' 0.04% ' 61100,- 58 8:80%• 3.58 t:. Out of Cty.SCCC0.03% 6,100 '' S1 44.10% 3.15 NYS Real PropTaxt,aw 0:94°I° .6,10o I` '13.98 258.70%- 85:36. Mattituck FD 6.31% 6,.100 i. 94.033.':. 360 ° 573.60` Mattituck Park0.91% 6,100; ,:;: ,x`„°';',13:64t3;;- ,11.00%4_.:.. 83.20 —T Solid Waste District — — _m...T 39a/o M� .-._,_M. ;--:2t37Gi :..:-3:90 I _ A 9.62% T FIRST HALF TAX 4,546:70 , SECOND HALF TAX: 4;04671 TQTA1 .TAX LOY := 9;09.3.41 DUE.SEC,1,2021 PAYABLE 11VITHOUT PENALTY TO JAN.10,2022. 'DUEDEC.1,2021 PAYABLE SVVTHO 1T PENALTYT4 MAY 31,2{22.SEE REVERSE .: SEE REVERSE SIDE FOR PENALTY SCHEDULE. SIDE FOR PEidALTY SCHEDULE AND COUNTY COMPTAOLLEA'S NOTICE:, HIS TAX,MAY BE PAID'IN ONE-OR fVdO INSTALLMENTS Printed On: 12/20/2021 At:01:32:49 PM r p ,L�a LEASE -AGREEMENT 04 � / AGREEMENT make this/CG�i day of April., 1982 , _ (J ' fi I /l, I between NORTH FORK ,BANK, & TRUST 'Co. , a,,.New York banking corporation with principal place of business 'a,t 245 Love Z5 ' I S Lane , Mattituck , ,New York 11952 , and The Town, of Southold, / a muni'cipal corpo'r'ation with off"i.c.e and principal place of d. business at 53095, Main Road, Southold, new York 11971. 1. - Lease:, The, Bank leases to. the ,Town. ".for a public -� parking facilfty that p.a"rcel of , _real property- .at Mattituck , (� Town of Southold, Suffolk` County , New. York, de scribed follows : 1` bounded No.r'th by Pike Street., 'West by Westphalia Avenue , South, by the,".'Protestant Episcopal Church and ,The Town of 'Southold, East .by Langer and the extension so.uther.ly of such line. 2.. Term: The Lease shall. commence April,, 13 , 1982 , t-t And run for a period of ten :(10) years. Thereafter", th,e l the lease shall be 'automatically, extended year to year . unless either party de,liv-ers written notice of •'c-a•ncella"tion ` sixty (60) days prior.,-to, 'the, termination ,of the ' then current' .` term. t 3 . 'Rent..: The 'Town shall pay to- the. Bank the, sum af . $1_00 ger ye.ar, in advpn&el for each year of the le.ase,I 4 , Improvements: The Town shall , at its own cost e an - ex.pens,e, .amp:rov.e."-the le'a'sed premis.es.' in,.s.ubstan.ti`al`ly, -t"he, desi.g.,n indicated :on_ ".P•r;eliminary -,sketch Mattituck.: P-arking -Area" prepaxeda_by Young ..& Youn-g ,_ Land 'Surveyors i a • dated January 5.,., 1982,, Rev 1, February 8 , 1982 , except that the driveway ac-ros$ the southern-most 'porti•on of the leased premises shall be one-way only toward Love Lane. Adequate i , paving and drainage shall be installed by the Town. Such I ` I improvements are to be completed within One (l) year from the date of this Agreement. The improvements shall progress to afford 'uninterrupte,d' 'and. unobstructed access to the . � • Bank"'s drive-in facilities from 'Pike tree-t;. The portion of i 1j the premises denoted on the sketch as "4 cars - Bank employees r, s: only" shall be reserved, for bank employee :parking only.. At ;t the expiration. of `.the Lease term or .any extension or renewal , ' thereof , all improvements shall become the,.property of the iJ �< Bank :and the Town shall not be entitlmd to, any compensation therefor, except as .s.et forth herein. 5 . Easement ' Agreement.: Thef parties are executing an easement ayreeme.nt 'simultaneously herewith. . The obligations of the Town contained °therein are incorporated, by reference herein: Th.e improvements on the leased parcel and the parcel to be a'c.quiredp'by, the 'Town as described in the Easement Agreement shall 'be ,made such that the 'ingress and egress over the leased par-cel .shall meet, and correspond with the westerly aisle 'and' `the, Bank ' s right=cif-way. over the. parcel to 'be acquired. 6. Reser"va't.i on of Access: North Fork Bank & 'Trus't .tb. ' hereby. ,reserves' the' .right to ingress and egress over the leased.,,parceh. from„ :P:ike Street to its :property, {.; such access to be (a) over a 24 ' aisle substantially as shown on the sketch from Pike Street t'oj3land of the Town and k, (b) from the easterlyVnd of the .right of way described in x: Schedule C of the Easement -Agreement over the ,southerly i; portion of the leased premises to land of t,he' .Bank , substantial y f ii as shown on the sketch,,, the latter to ,be reserved exclusively for the use. of the Bank. 7 . Bank Contribution : The Bank shall contribute the sum of $1,0 ,000.`00 toward the, improvement's * required to be made The Town shal-,l be solely responsible for maintenance and repair. 8 . Par-ki,,hg,: 'Bank.. .empl,oyees shall have the free and unrestri•c-ted right to park in the, town p.arkIn'q lots- covered by this term and .the town lot to b.e terminated to the south of the bank during B-ank , b,usiness hours , d'.uring, the term of this lease or any "renewal or extension thereof. 9. Easement on ,'Termination of Leds'e : Upon the termination of this Lease or any extension or renewals thereof , the Bank shall gra•nt' to° 'the Town a non-exclusive 24 ' easement for Ingress and egress over the leased premises from the northerly endof th:e' westerly aisle of the Town ' s parking area on the -p-arge'l 't.p be acquired by the Town to the south .; of' the le.a,s'ed premi.se.s. ,to ,6i.ther' .Westphalia Avenue or Pike Street, -such location to be solely "_w,i;thi:n the, discre.tion of F . -the Bane. This provision sha11 survive the termination of the Lease and be forever binding on _ the` I.D. Pike '-Str'ee't. -Parking•°I'o,t: It. ,is un'ders"to.od.".'that' �•".. the Bank intends to convert the former Levine Building on Pike Street to office space . In the event additional off- street Parking is required by 'the Planning Board in connection with its site plan approval, the Town agrees to release and s, terminate. its lease ' of the parking area bounded North b i Y Long Island Ra?ilrcad; fast by Love Lane, South by Pike . Street .and West by Westphalia Avenue upon 30.days prior written request- of the Bank. ll. Use. of premises , Assi nment, Miscellaneous : x during t e,,term ereo e , an The .Town shall ex ensigns or renewa s thereof, at all timesAaintain the premises as a �J public parking fac, ilit Y•• The Lease may not- be assigned or i sublet without , the %Vtit.ten p mission of the Bank. This Agreement may .be'modif.i?ed 'h b +, only y a signed writing and shall £ be construed in a-ccordance with the laws of: New York. t . „. This agreement shall b.e binding upon the parties.; their successors and. assigns, IN WITNESS ,- WHEREOF, the parties helve executed this f, Agreement this _'Z4E day of April, 1982 . r T$E:.NORTH FORK, BANK & TRUST CO. BOY 6 /S! 7"ay rte. THE TOWN ,bF SOUTH-OLD By .. �� Pea f`Ti STATE OF .NEW YORK) ._ ss. :• COUNTY .OF. SUFFOLK) ' om the/11A,t.h d'ay of April, appeared1982, before me -p.er,sonally, to. -me -known , il• who, being duly ,s�worn , . did depose and say that he resides at rt' that he is the of The North Fork Bank & Trust CO. , one of the ,Corporati.oms described in and which executed the foregoing instrument; that heknows the seal of said Corporation; that- the Jeal affixed to said instrument is such x corporate seal; that it was, so affixed by order of the Board of Directors of said, corporation , and that he signed his name thereto by"'lik,e'gorder. k / - a � otary Publics Nom'PubdW its 0 Now York STATE OF NEW YORK), No.82-48428"®.Sutjotk C�atinty ss.. .- Commiasfon Expires Macoh 30'l i— ,COUNTY OF SUFFOLK). On the.,�9;th day of April, 1982 , before me :pers;onAlly cameo 'to me known, who , being by me duly sworn;:. did depose and say that he resides at 3A A.v fx-r' r2�id �"yer.n-�<,–� that he is the �� =,�vf. the ,s<,/< Town of S.o.uthold, :one Of 'the- ;corporation's described in and which executed. the ,f-oregoing instruments that he knows .the seal of .said corporation; that the seal affixed to said instrument is such" corporate seal,; that. it was so affixed by' order of the Board :Q Directors of said corporation, and that he signed hisname thereto by like order. C.01 Nofary Public RG3tR1 1'!'.1ASK.ER NOTARY PUBLIC.State of Now York No.52°3933725,Sutfo k County Terni Expires March 30.1983 r. 1 ° 1: d ' C�ecocd f^ 7.7 V ork 1t� N �ornPa�Ma��Stre11�1 127 W' N.Y• , R��erhead � • Return tO' o E4 nU. to o ' J ti' t a Fes••{ ® tJl U m 0 Z 14 Id v U �O C� tL' �a .'�-r �— Z H 7! E4 ( � 4.) � ' Q 1 • a f r if ,i r� 2 1 C. if 30MJ -r irmi:.,•, K 09 69 T S r f F'< a r a 3' ,j sh •",a , 1 •L' Y' i. i •1 I` i< ,Y t ,v , I 5 S I 1 i I f3 1 S {• l' i I Yt ry 'i I •V ,f' T, 5 i N• a, 1'• �r i. ii 'I: t. ,k Y i,.r, •V.` 'a,. 'r,t,.: - r I k I'# � 1 n 't k i •i 1 1 't 1 'I r F1 , I 1{ I � i 11 r 1 ,I f 1 •}• i 7 I : I i•t { I I i � I 't ! i f i• •f }i I' i, I # i .l I' ! d ! I I r S 1 , I I I}' N } , V t` i r I' 1 11 I ,'Y LL x f ++ Y r 4 I I 'I 1. I f -II 1� :I I 1 1' 1 i 1 i I { I t I t 1 I rHr 1 Ir I ! I •I i ,h h I I < r i {• it I i i ry r I 1 { l 4i I 'r' l I I t. t I I• i, 1 'I ar' I r u [ S r •t. i 1 i 'f t I l 1 r �I I• •I I I i I i I r I' t •i o 'I 1' I !7 i t ( f. i Ir I } I ,. O .- t* I I j _ j' l :i v I �•! f •{i `a 1• .r' I.f' "r `+ i hQt��� *�1Jt1•t6 \ "�i '.1: 1� ,t•a i-t 'I 1 I i I I r a a' r 'I it+i 'a I xr •'i AN v #z J i l I P <D ¢ I ii I I li a •1 YJi I 'I. �Y• ''I Ik 1' �. �" •t' t) l f, , S I: Y il•ri. 1" ,! i 1 �I I I k •i,, t,, ,I i jjy f i• ''t, 1{ 1 I I 1•. x' I r44 .�y' T I •t ( •" (�µQf• .F•r•.�iGir 4. .ri�. r I : ! ,I' i � I I FI t t f i i:;. SWUM { ` 1 1 t t J t I I r\ r } { t i' •a e 1 yi _r,, ! r r f I ,S, :i•Y�} 1 1' w I' ° I i I I I I c i-• I A 'h' I 1 ;i r � EI i b } I r l - , I. I A'• , I `7• f d } .1 1: 'i Y• 1• +I. artAaw .tg.�s` », t: is I w' r , I l: I I" I I I�r, I . I. I I A' } a � _ r t I f l � ( i' 1• I' I i' ri {• r t a' I , i f rrir- `�i ,1{ :✓' '�` 't,` :r 4,` i , 'e -,'I, iii 'r I I i • r t• w i I a. i' 1 , r r Ij ii •h 1 ! ! I 1 1 '1: ^h i i 1 r d z r i ri' Iw r1f'i L: -,j { r v •a I' :li"' I I t'A , a I 1 I' I . I V : I d f LL l•. •;F 1 t t' i l+i" _ •I , I I i 1 'i r z' , I i f.• i +d V i• s !o L L o � r I' 3 F 1 i.t To nt7• E a r i I f F •, u' 1f. 55 i L<' a rY 1.- ! 1 M Y 4 1 1, , � F , i • iC 9:. 1 I, t' i #i'I"t'1N1.E4K t'r'C0 L �•'Tf•Af 'f'Si. '� '+E; 9�d' i I, .,I, 4 4 � �•:,� Iii, i '.,I" „ �(`'"'"''''`'� 1 7'. Y h LEr>•'t�l•.4J4 : � ',r' { Y ,. I`• 'r,l'4` It i;,�w,.,J, i:. 1 I I: P 4 � t�ouNot-� Mcwo 'N•. o, ta i Pr ii r 1) K.itY't R•i6• �':GAUNh1Blw -• G• p,' F� `nY ,i 1 u',, ,,i I Jill •I i 1. � ti.,4.'ili l" w � 'I, i• , i yyYy� a 'D• d - - � tIt .i+i I:. •.,�L,.-•'-„ ,1 iLr.r51+r+47w, I, t .I ... {, _ V• .a, �ar{q� , r. 11 :I y{ I ,{;� •1•t I ' ' i a O \\a �Lr_ I .V"'. ' I I Iit }}'►m{� 1 ...-+ r`It;, ��• � I .{!' •+" y , Y i i M '9. 'iy• 1 If 't.l`} I i I I MAN1-141;. ' r--"f'A1 k, �0Q1� •(j• .• ! "'•`� ,', r : '�' } ;r' •i'ii t,#9 i { -i,,J 1 11 ' Ir, ,ri ��yy�� J,�, , .�Y:�,( '� ,J.. 7 t. J t 1.51.,.�t f� nl'�°� ,I !• r # t I , n•,y,.� �',.' bf ley+' .�''r-•.,ter r" FiP ,. t •a Y r .'�r� k:ii. ',i . i .rA .. - - ,,,, �,i"},,YT''y �•- '.�: ..*''".'fir,, # '1a';. '9. ;[•, �•. _a.. ,.L..,�,st' t'9� - •T• t '.�r, '.t�,4 1 ,1 ".t0.< __ _�.V-'^�v i.• vlt , 3 'RP.'T'L'Ye .!f, t:l"i'.f,�i,'yltli'Y' ,NfiLwlXi}.k,r �' "0. ' .6�i'mwnA. rl 4.td Sp..k`, _+._St __ , .. ::,,i• Hy F,.� .rt :''!hU'O, 3�''r' .'St • - :1 \ w ,!". -+r _ -.. y kP�•' i�`•'v"r'Y.•CYY)p ,,,,tttt i n��1�,•U 4' '•R' NR �" t , r .. -' , .[ , ... a ., .. « .:. r.. . ..:, .`v• �°. + 4 , r P Jk i •,� -a 7 r.�'• 1 'z F '1J,.r T} I "3 X yy �p Ox •'1• - .y V r t U '.•i' i•t o !1 I 1t '� i• Walt ;rt 4..;.; "t. '•11- Y - ,a. ;c+'.,Y,:'.QTc tt'•.d.'L. J G I 4 ] ��.e:I'., �.:' `fi• ;'7,,'°'.''-,. 'IF� 1°i ItitA' A, ti' ,t 'dz•I v '�' 1' I 4" 1i it ;i� , I:r� t• h f" C T' al,, _ •i 1 a. C t 1 , 9• 1 7 r E J i; r a ,* _ " �i - _. 1,', 't { i�` -\ ."( rvi' 1. ,{'I rl tiY'u '�'• I `i7 r' 1 VG �®Y� liijy 1 b•00 O �19 i I � � r, �, ,�,��Q� OG• ',tQR '1 g 'nj i �•'K' ,�„rr.� � ��, '�w� I , I 'I /}''I��1(', �l 1h ., .. 'T/G*1t�.1 i '7�L:'{,(!.1 e''t►11�iNYL' wawa,t"� i �If,71os,H 62'�dk•AVt' Y9, 'I Oi �� �Z '� ',, I ` t I , I r 1 .j` 1 71c.F +fo.YJ :IG.f c! i ��Q, �j .;I - +t #'• /S,: i. ,�I .,,. I •k..; i ...,; ^'i 1.b; ;'t i •r� ,�y/'�•' d �i•� ', I, ! I 7�G q `f�G !e•1 F�•` �� Q ;, /- y Irl {. i �r �' 1; ,w• `I;"M:,'^: � 'I''t I - 1 r•„N. , V�. .P',' r \ I 9. 'I'5 '� i�� I I 1 , `i '�o-' r„( I 'I tltl '�•'�. .:3+ rz'a t eY 1 t naY�1 ,•r., I ; I + I L'rl►n4 9 �? L•[ 1 rl \ I: I .1 ,,,,k ,II "k"`J 1 r ,$- {: y .j, _ •4!' ,�• p+G '}' i {#({is i ', �'1, �g�r.}�, � ...� fi8` t .r• _ „i I I �I, ,r ■ q` .'"•IVG vr� 7b 4fit " PVG ',9• - Fj'L; ('i ;r - ' .L' =FII[OM iA•2i1b1.1 r I Li; 12. r.'' �.' 16 c 13.5 , i (' .•s,°x �, _ .i' ; ;!I E' - .,Nlllt.If'i7zl• - ; , '.i �. } '# 4" ri'-- '��"h �� Fe �' '�' rD'dC PYi 0 fAaJK O p A L h P I G YA rI K O� \ i cyt u ? • ` 3 3 • r t`S�GC�01..6r z °00 6 E T I ,1 G ,gyp 'r i I ,r, • E., j'. � k ril I,. ✓' 1' 742.0 al:.1!S cAc '!` r r I r 5 'r #. j I,I 1:I ;9. ' t E.n 14.1 Iii ..� �•. 1• r W4LL A�t�EA �,. ! ,1� � I .. 1 i 'I +r 11 i } nlro#T lsAeeArotS N I 2'P•Itrt. ,sreo�uo WA7ilk •.'3}+L•4., T � '• , t .r % -w.-•G- - �(L�` '' s, ,`i, \�.`" 9� i V i I I r•�'.,ev`., � row. '} {' lk°! 1 � '9 II i, ' � .,._ ...._ _ - P I #^' � I ;o �- .r tw ;'ter >*�• I 'I i ,I GAL 'y�n/a6 .,. t�iFO40A>. h'+' `t'�N► ��ae 00°° ° . �� `7 A 1t`A. O� to-ell � -"("' � N+d1'!M")1•.al�'rt"� � 1 N ,i I ,1�1�, 1 , yQ`I,P O� ;1 F pgQ� t 9., ;N Y j7 RO lul N" i1 A L. I+ I I � Ill ,II°I �l , I li ;!• On qq P 'ft9,'�`� �' ,,tet' .. ;I' 1 ' ! I 'I' } lmill{I,iu, •{ !r r� r r r x/ I # I r "I r i ."4;. ♦ � . .. i ! .L � p0 _ .. ''.I; 1 �t SfdktYET'.r:4i'{rr"wa.pr' -'I�r:�4L�•.-' 1 ,� II;i,;i I•II!1''I/`' �!� I I i ,l .jj aY r t I i ! i t'I 1 I, I' I' ',i•';i'`i;!{ii}. , ! an I , ^Jr s 0 QQ CA«0!T ff201rF+CC�VEN4� 618LT. FROM 6`CON TO''t`11..'.A4.1.J.Qh/�t�rr ,;i p, d_bF'f7 AG. Y 0 1 AG, = 2& 0 m�C Q� , 1 i 34.3 '�A1.�t`t'�1i "*{ �t»l».Q�' •• 092 2 „bJ+(\�� I 3 8 t"�"�+J"T15►UA►tS't' ( 11�t:1r tip .�. �O �o \ I 00 4 13.6' ars '46:LA-rr4;-> t� 1 D',�*1°7P�+�Cm.T � ,330 !v�'t7 { ,� o,� i t Q' 2 i 5 18 r2' ! � 9,'2' 10 . - r - 4 ) � . . ' �! pB25CWV P-11-001E.001E APA1Q' r : 01 200 �Q. 10'"� OF-I-ee1!c AWW& 90 ' ; 36.2' G Q• i . a. 405 ♦ ria i TOTAV tiANITAI� t t=-LO��/ - 3T5 GrF'D •I ,�3.;7. ; q., ,i+ , r 't ;;.. 575- Q V P &f- At >Fs tzE: :�, �!.•r>' •r i .v. I-aJ I a,rp"..;,a +I.R v, Sr• ..q, 1 r •A %. s •.r, tt :. r r�- I .. .' , ,. r - .. r.r.,i,'i "" .:. -F.. , y��!. t+` "i .;y. ;�°hM :W'k,:a••h"^a2.'' +•a9M. '%v:'-fir•k,� - .. .. .. r ■ire : .r r , , t .. r •I6 is .' ° wr";i,. ..J, m , �. Pani .,'{ f • 1 r 3 rag i. ( ! ;I^ .P.. .,r••: •.,.` F�' �i. ,r q b' � C7 'l�• r�,°•. ,,,t. ray ".l "I f •"3. 4 9! i asamoY��uirri { ■ ■ I Y11 tl //igyy�� 'Tr. fLx. I' 6' '� R„r A IY•IYIII■■Growl• I a■� ' Fr "S. 1 `/ J,! q� 7' d b 1: a' 1 rat , `�� i�' •fit, :.C. a� , y , i� tt i a8 i 1 .j 1 •!T •.i= lir' � �`a r i I• 1 ',d oti' A1' 05 t9 ,` KIaA IJ r f' a' F 'z r I •i t 1 v r*K 1 1 1•. I' 'i S 'f: y''itr,:'• / I' Y%.J• .ih n 1 fs I yy •1'r• {J '1 h! [ tom' r ,y la.ray ► � '�"'t'�t ,r.z .x^t .4r 'Z �� � r 1 T N , .t 4 r C s s• ,;'{, T V .,- ''i t r 4'� C d+-• C" j is• t va. a't• n• y h" d �.a' 7 1 tii'- , .4 r r r � ,.' -:fi#""q3, y ` '"rj:•F ¢¢•• :r,^ .ai{iI)¢''�'� ,,.',. 1.}, „rr1: k. {it',,.,, r'i'•'„'`il...Sn.. 7.1�'. �i,`g1Y ,..J,..��!i ;'ii' ,r d r;il .•;}'r ' .JS' r ,. G .,.A' z a i:l �,,,.r.l xr r�,C�i.•''"` tJ.: ta# I 4 r ,•r ,. r t•,. S� i+ •t o' r .r'� 'I ,1 ,!r r x:: `3 i' I 1' 1 � � z. r \ ,�� 'r ya, •at P et E 5 a ,1 �.Y i O 'ti' 'a• x' •i` t •i" ` it p, P s y NAND O Y sr' L A r•� t 'Y V Com•, 5 t'q \ 'S 5b :LsA A tii �' 0 I' i 'I it 1 1 t i r. 'Dn 'P� t• •Y' i 'i i 1, t !! k 1ss ,�i��)�'Yar�y. �i V 1 '-a' •{i '•x e .}' `r . P' V gar i,�G•. A. "i ,.r:1•', { Y r 1{ i" I' f• I I Y z: •r' 1 d• ,m .:hrl 1 •i , I r Y _ -fl � a I #' 'r t' to T K A v f le t;+• A 1' Y� , ii - •i- i •.I. Q f I � , k k r I I o' tt •,i t. rt 1 .,• 7 tr 1 V 4 1 `i 9 i• � I ef" a � I , 1 � •k # 4r Maw 1•^ I I 'a, • n 1• r o I' r' ! ;r 1 1 I-n ,.1 t 1' "1 pp V I 1 ! 8 4:• 2 'I .i r ; � t 1 i eta j r- f r A i• I`' , t' t w 4'. 1 > p' I II I 1 i { nF, }} L i �9' ry �' /• 7 r 1 r k "J'1 'I r I 1' e 1, i= '4' '''I f '{' •I e N D" II 8• ! it a' i 1 1 •, 4� 7 r•'.V Vim• tfrV \ iiti' 't. ,l;l' t ,l 't i" Y1.. •r ;Ir 1 w N• s r'� 9F t I i• I. I' # 1 '1 I '!` t ri::•.,L j }[ f' NI � I'4 ', 'fi, '1, rf 1' i r k ' •+r 4nID ,�n "�!} I# i$• 'r ;J• i r •1' t. 11 i � f I 4' i' •'I ,;!I: is 3• .I" ri''L 1r19i 1 t •# n� l: J v4 'k ii i'• f 7 1 N l• •t r 1 1 J 'r q OFr i •i y 4 i, r � 1.• 1m"'f "f'Ilk•96. l >rr x t tb ti7 W &'... 1 A` Q Ess y � L- ,Y` m ?i I �• z� 11.9• - �,-J 'a' •;; r,::.+ ,' ;'' I ,i '.t e' r,l'ip,1 .'� %: j• w� is {r, • r I `r r I �'. 'Y ,y;:i, I{.`•, 11' l+":Y 1 It, I k7t .A IA. '1: ,'.�• 'I i `✓r ,t 1 .'!i 'f' ,�ry5 t !.,' 'a, ,l` 'f i �i4 ^,p�{':'�'. r sa 3 • tl a 4.1 'i1 tJ I l�! C OWN ER lr i TO ;� •��4''� r r, d• 1 j ( 4 rA aa'il ,Y I 1 r Glti'A ttia,�tr av CHARLES A _ES J. ZAHRA O7ttJ l; I Y r= h ' v . 8�p PIKE STREET 'I',<. �� � '•i' ',}' r a REE •i ''I ',`;- I I i' � �� � ti ,w ` I . ;, f I• I i 3 i •, MAT 1TUCKeN.Y. 119 2NOt 3 [ k r+• 4 ^+s I t' Cl> ,r• Y 1' x f {• yrr i. O.sAit' tdOMEN T' IO U EN, ',i` i •� t ai' 0 t' r '6 I' ,1 R+: Y1� ,r�I', �/ r w� Q r�, }� /'�y�.'T -J'A.i. U I 6 `1: '.7 n l� I $ lbT r I. tom'p FC'i t n a2' f f..Fa+lf � N,'ARE tEFEtENCEO3 ELE /A NS StCW ^HSRE I I ' , • �w:J', f:. 3,<. `J 1 S I .�• ;I.^,c•i.' .;fir", 9 ,- �f ,,•s I: ,. �►"Yr1QV' /� ,�j�� i�'• it s,� rq 1 1G• :j '1, ry irr r�,tac• To tv:c.v a. *t SL •r d t •`r' i f J i' r J 4 tiS.�� �Xt3T NG Et .VA 7 ON I' t I r r. fi h' d �t D C' I "h 1 •Y.• r. F' A rr `r r r 1p rl i r d.i I •a ,1.11 ' _ 7.a ria , r F° K '`l'' a '3 •1, 'l r k' 'ta rli .a I •i � { 5" "t• , •n I il• ,s> '1 4 .f v '# .I a• � � t 1 t 1 I ,I' •i" 4 I r �1 II I n E 9 1 y a 'I+ Its .•a, s i , y I a I f Lim i•. t ! • , 'r •1 (ry� :I 1 a l' r RYY x • rt`=` �' Iw 1' eta, i ,S C , ,a, I ar ih i+ t' i" E Crt ^2 •'I' , nr 7$(5 [ ,.,, 1 •rl, •1' is .1 a• t /' i 1 La. '�• ;M1e^ t t I j f` •4 r •1; i ,a t I .,. _. -_ ... _._. `i' t;, 'i„a4 a{ n! ''N ,1`,F.x i, +'1` ya.;' '(ri,; :i 'f.,."�' •t �: i. A , .c r• I iI �II w i �0 � p£14•ppvE"E, 8 i _ i i c p/•, 5� R0 000 3g AO r'o 0 t " oo• �0 / - ` — / N0( . II _- 5 6039 5 580 0 •' I 6 0_ 04 0 22 o 60 � ,';i<+•},ic. `',py lig .. xs:r V Fr °<a. o_ REQ s 37�0 9, • _:fi`� _ •_ . . F r o VR►b ►N SDEWpL 8134 •a - VAUMORIZE0 ALTERATION OR ADDITION TO }}IS SL'-'!-'y IS A VICLAT`pL,U OF g 7� ' - 00^�/ SECTi.... '=:i ,F . -nav?C%C STATIE O { 03' EC"'CA LA<,. I 'S.7140 GC'r'PS- VT; rr T TEMING S79°465 To;� s:., F E GARAGE ,� I 29 aE RAM �,:•., :. . :_ C-) GUAZANT:_'_ WN 70.35, 11 Fr.Ely„<?v.,,; •;• :-_ :.�•-•:r ' 1JT�IE iiTLE COST?n'7!. A!%,CY AND tVgD,K:i 44ilT � _ o44 .►,.w r TO THE �.:_L .•_c-79 fGiKiY<GUA.<AN-4' A.5 r.L:•T.T.:Ar-SFE"AKE r 0•2 , ,, � ADCt1FONAl Eh1TITUpOr;S Cfi:V15E.pUru• c !.5 1 ;{ ,�;� 0 12022 DD Q, s AV I � BUILDING DEPT ali \, o26r0„w j Rc'VISE•p - APR. 13,1982 SURVEY FOR TOWN OF sou THOLD ,F AT MATT/TUCK c>S. M i SUFFOLKrOWN OF SOU THOLD P� h. `o - COUNTY, NEW YORK '�� A'` ' i SCALE• I" =20' j Y fr , s - MAR. 8 /9 ot) NO a2GU,ARANTEED TO: s 3 NOTE •-MONUME//T U.S.LIFE TITLE/NSUR,9NC£CDMPANYOFIV/ YOB K SUFF, CO.TAX MAP-D/ST.-/000 SECT.14/.6L K.-04 LOT-P/O 028 • ,�,,� �gag3 SllRVE'1�0. } YOUNG a YOUNG, RIVERHEAD, N<Y. ALDENW. YOUNG, N<Y.S.P.E.$L.S< L/C.NO./2845 u HOWARD W. YOUNG N.Y.S.L.S.L/C.NO. 45893 FIRE ALARM SYMBOL LIST E L E C T FR I C A L FACP 1 FIS ALARM CONTROL PANS KIDDE EDWARDS VS-1RD NOTES FAA 0 FRSE t L.ARM ANNUNCIATOR PANE. KIDDE EDWARDS 0 ALL WIRING TO BE INSTALLED ACCORDING TO THE LATEST REVISION OF THE N.E.C. AN[ R-C I-- ARDS ALL CONDUCTORS MUST TEST FREE OF GROUNDS, OPENS AND SHORTS. 1 DOUBLE ACTION MANUAL PULL STATION K E®270 z Q �3 ALL TERMINATIONS ARE TO BE SUPERVISED BY A REPRESENTATIVE OF GARLAND FIRE ® 1 PHOTOELECTRIC SMOKE KK°�DQE�®JWyARDS FM4 MOUNT ON AHC=ABOVE CEILING KI-OSD W/IV—�70Y -�- HORN/STROBE III C sorroM of - __= _ -_ ---- ALL -__ =-icor®wARos=- -. ® RECOMMEND WIRING AS SHOWN. OH 0 TMIE�-DE�T� CEILING; MOUNTED CEILING TILE �� Q 4— DROP ACOUSTIC TI AHC=ABOVE CEILING � FOR COMPONENT WIRING SEE DETAIL SHEET AND PACKAGING MATERIAL. � 0 DUCT SMOKE DETECTOR GSA SD S=SUPPLY SIDE_==— O BACK BOX wl T- AR © SHOP DRAWINGS DO NOT DEPICT CONDUIT RUNS OR QUANTITY. CD DD CD� 1 HORN/STROBE S (� U (D >- HORN STROBE �D L NOTESI INSTALL AREA DETECTORS A MINIMUM OF 3 FROM ANY AIR DUCT. STRO E ONLY )< 0 STROBE ONLY MGR-VM Cn a) I. T-BARS REQUIRED FOR CEILING MOUNTED SMOKE ® PRIOR TO PLACEMENT OF CEILING MOUNTED OR DUCT MOUNTED SMOKE DETECTORS OF POTTER < Z DETECTORS AND NOTIFICATION APPLIANCES IN AREAS VIBRATNG EXiB�IOR BBI- MBA-8-24 � WITH SUSPENDED CEILINGS. B 1 ^ •— .Y 2, ALL EQUIPMENT SHALL BE INSTALLED IN COMPLIANCE -'--'_ - --_ ..3.1 WITH ALL LISTED DISTANCES, LOCAL ORDINANCES AND REVIEW MOUNTING INSTRUCTIONS AND PRECAUTIONS. CONTACT G.F.S FOR INSTALLATION _ Ao KDDE®WARDS / MANUAL PULL STATION D o © O ADDRESSABLE RELAY MODULE 0 ��� o }, NFPA-72 RECOMMENDATIONS. - GSA-CR ♦V T-BAR/BACK BOX MOUNTING --R�--- -____-_. —_- - --___=_�� KD�E®w,aRos-_= - tet- - , ETA I LS . SCALE NTS TO AVOID NUISANCE OR FALSE ALARMS. )1( 0 REMOTE LED �A-� `W^^ Q CU O9 MOUNTING HEIGHTS: DIM 1 Co -WATH -lOW/TAMPER MONITOR MODULE KDDE EDWARDS O _ GSA-WW or GSA-CT2 O A) MANUAL PULL STATIONS: 48" TO CENTER uvF 1 SWaffiWATE3FLOWSWITCH RHMiM o BY 0- B) VISUAL: 80 TO THE BOTTOM OF THE DEVICE OR 6" BELOW THE CEILING. TS 1 3PFIINKLERTAMPEiSWITCH ��D� �0�/ OTHERS LL EXACT LOCATIONS TO BE VERIFIED IN THE FIELD. FIRE ALARM DEVICES "MEEDWARDS D.. AIM 3 S�'E INPUT MONROR MODULE GSA�T1 MOUNTING HEIGHTS AES 1 KITCHEd HOOD EXIINGUISHNG SYSTEM ROME)BY Onfm DACT 1 cELULAR COMMUNICATOR NAPCO STARLING-FREDIALER SEQUENCE OF OPERATIONSCo 2 CARSON MONoxIDE DETECTOR �''VISOR a 0 -- o NOTES: CENTRAL STATION ALARM SERVICE TO RECEIVE SEPARATE+El DISTINCT SIQNALS INDIVIDUALLY A3 FOLLOWS. • „ ¢€; y'i ro� 8. 3£ / %: Y.; r; > o n Room : . 9 cLUDEs FIFE ALARM CO DETECT SMOKE DETECTOR I z u� A) (IN w a SPRINKLER WATER FLOW KITCHEN HOOD AES+PULL ST A a FLOW, N T P AMINER: - OTE O LAN EX 10 YEAR BATTERY WERED B TROUBLE SIC;iNNAL A B TIER PO ) ✓w""'F T CAROBON MONOXIDELDETECTOR 0 „r. ,r i SHALL BE INSTALLED BY OTHERS s,.,.,i,;,. ,. C SUPERVISORY SIGNALS AMPER SWITCH ON THE 2ND FLOOR ONLY. (T y:. it .sx g ,ry F 's i.t• p CIA Kitchen ..v:::::;o. Q FZ Q Q Q Q Q Q Q Q r;. s, Q N ' W L -1 /'7 r z F <o: .Y, 'Atiluck cn X X X X X ACTIVATES Hz 01 LLJ ORN AND STROBE BY MAIN ENTRANCE DOOR w # s _ 66 X X X X X X X TRANSMIT SIGNAL TO CENTRAL STATION ( " F t. Living I Bed Roo C! 0 oy „.. Bedroom LO O ACTIVATES CONTROL RELAYS FOR FAN+MUSIC SHUTDOWN':_,. 1111 .. ys',�s .' W X ACTIVATES EXTERIOR VIBRATING BELL 2nd Floor PIan SCALE:B"=1'-D" , a TIE—IN TO ADJACENT TENANTS FIRE ALARM SYSTEM f" : (V NOTE TO PLAN EXAMINER: >�> IT IS NOT KNOWN AT THIS TIME `' Map dai t�,40,2022 � IF TAMPER SWITCHES WILL BE PROVIDED BY THE RPZ ON EXTERIOR K E Y P L A N ( N . T. S. ) Q g UP m DN 4 NEW NEW Fir Sprinkler Riser/� "'� Lj M NOTE TO PLN XAMINER: ClassK NAC CKT-1 w z THE BUILDI G ILL BE FULLY NEWO ire Extinguisher STROBE SHALL Q Q W WET SPRIN LE ED. 0 0 HORN/STROBE 1 REMAIN ON it _ ED � L��— , SHALL SOUND UNTIL PANEL IS Mens Lay. Kit ryz, ' TEMPORAL-3 RESET. HORN ( � Ladies Lay. Kitchen PATTERN AES WF TS 1 DO L o e o SHALL BE �D '0 Q tD NEW NAC CKT-2 SILENCEABLE. A 1 Ax2 J Front Entrance A Q) Q M r A � v- o Z..g.. 1 1 1 1 Axl o CO N -' o F AIM DIM AIM �a w , w N co / M � � oN ❑ ❑ H.]Ei 1ST FLOOR /L� w z � M -' L � " ❑ ❑ co —jN N O Z N E J tD Q W , F CO W � � � _jUJ �/I'� F-- (n Q J Dining Room Ax2 Y 12 lv� co L ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ nox Box M U W Q I >'- C> 1:1 El M = - � wzzz 1 1 S' AIM Q r n z � 1st Floor Plan SCALE:0"=1'-0" z B ADDRESSABLE LOOP Q J W FACP [LA P1 g _ � W N W uP NEW o FIRE ALARM WIRE SIZE: C�LLC� 0 A: 1812 TWISTED FPLP 00 VS-1 RDk" WIRELESS WIRELESS Ax2 B: 1412 TWISTED FPLP * COMMUNICATOR IS COMMUNICATOR T APPROVED BY U.L. WHICH MEETS s NFPA-72 CODE. DACT FACP ALL WIRE TO BE LISTED FOR FIRE 18 2322 ALARM USE AS PER N.E.C. Q -kDING DEPT urnaces Ax2 OFSOUTHOLf, STOREROOM CELLAR pF NEIN yo i Cj t * w ,m o: WALK-IN TO -.11 .�,'-� - N w COOLER DEDICATED Q Z x =r � 120Vac k ,r CIRCUIT � �'ORo�Ess�o`�P� Cellar Plan SCALE: "=1'-0'� Z RISER DIAGRAM EFF LARM PLAN NO SCALE HEET THIS AREA FOR FIRE MARSHAL USE ONLY 1 t� A z �Glrf_`fS f^FE 2'-4" /'" 2" d.f`.E..," II II I II I II II --------------------------------— ------------------------- II + ..r.�:.?;C £LFF.z�oR I I I FRYER COOKING STATION OVEN I I t 2'-4" x 2'-3"D '—C}"W x 2'-3"D 2i-11"W x 2'-10"D II II II a . II ' I II II � II <\ I I �� II ------------------------ - ----_--------------------J SF¢ F \\ i �;� _ F SERVER til / PREP CHILLER /// I ._._.____...__.......................__.__..... t F € ' 4'-O"W S'K..L.f-6"D HANDSINK I I I I I I I I I I � Cgl I I � rPREP CHILLER I I I FF LU iSATHI E,4T H EI Il IF] L11 ;.. �a '._..._._._... C� C3 ....... Uj LU CL i G CA C 110 110 I AT 1! I --- C> SHELF&TABLE 2'-O"D I I I I I I I I I I I I I I I I Z S" 2'-0" LU G" 2" N G`-0"LIJ I L - 00 i I i I I i t vi";'! g . v P .rte .......... f s > i �• � ��_.., i �� �� .. .... .._._.._...........___...................___....._.._..._......, a\�o'oc9 ti. ... �\\` 4A �� j�o.:, a�''.c�. .. � \a �\�a \`•��\ ��\�3 �� c px .gym r',' ft SC:�I..E. 1,{F2C tt�. -4 4(SFE ; { SCALE,. 11/4" `..',±!it :::: .4 t 3f � ( .............�._........ .....,_.........�.....�_..e...-.._.-. ..,_�ry............._._..____.....,..._..,.___....._..._..w...._..........-......_..__....... ..__ -..�..�,..._...... �i SCALE- 1/2" =, r¢t_(q}i # ISSUE/REVISION DATE 1 SCHEMATIC DESIGN 01.22.21 2 PERMIT SET 02.19.21 SYMBOL LEGEND IVALL TYPE LEGEND C ISTR .0 ION NOTES BATH ROOM FACILITIES REMAIN AS IS. PSE p NEW N.J. MAZZAFERRO, P.E. DRAWN BY:ZEN EUSix S V LL NO VlORK TO BE DONE. � p S --------------- �-=eRc,=c bV,�LG EXTERIOR�`K � �E���`I � I . o a P .t'r'gz�q�JI"�� PROFESSIONAL ENGINEER 02.19.21 * P.O. BOX 57, GREENPORT NY, 11944 �.�:<.R�. r�I=;rW.<�3 REMAIN AS I . NO P.O. * -�•- � .; �.t ��'C�RI�TO BE DONE. 516.457.5596 EMAIL:maz_lin@msn.com SCALE:AS NOTED 'F4b` ' LL "Alteration of this Docu"'en 4 s by an Architect or Licensed Frcftl�- do 5 09 ���� PLANS 1 Mona► Engineer, is ille �l." ,� SHEET N0: ^� Subdivisl)n 2, EssioNP�' MATTITUCK CAFE E���DDDR EXISTING DOOR rection 7e.�9, ,j. y. State Education L%7, 140 PIKE STREET MATTITUCK, NY 11952 A-1 ko Walls and Stairs above are V` to be covered with 8'Fire Rated Sheetrock R--e Detail A Re'—Af\ 3'-0" 3'-0" -Existing Doors 1. All work material and equipment shall be in accordance with the 2020 New UP stn D o 8'-9" York State Uniform Building Code, and the ICC/ANSI A117.1-2009. Landing Currently 8 4"Above Grade 2. All work to be performed by licensed and insured Contractors and Sub- Lift Landing to 12"Above Grade contractors. ` ' ! After Raisin N o 3. Contractor must car General Liability Insurance and Workman's j Fire Extinguisher ! � , g Landing �, carry ty ��, '-0"--i i \X' 21 2"- 12"= 9.5" Ris v "' New 2"0 Stainless Compensation as specified by State and Local laws. 0 ! -1 D ! ! �� �� ! 9.5"/131" = 1" in 13.79"Slope Steel Handrail �) c%� -CD O 4'-0T ! 4. Site is to be maintained in an order) manner, left clean of debris and -1-- + ! ' ` ! dge of Deck Surface broom clean upon completion. Contractor is responsible for the removal of � ico N � � site debris. -d�0�— a 5. All new walls or existing walls and ceiling areas that have been stripped of Clearance After Raising.Landing existing finishes are to be covered with 8"thick"fire-code"Type X drywall a \ , / 2 /146 = 1 in 12.167 Slope in accordance with UL Design No. U305. See Detail A Ladies Lay. ins ��V 6. The walls and surface area above the stairs from the cellar are to be 1st (V N floor and the walls and ceiling at the door to the exterior are to be covered 3' -0ff °x° p with 8"thick"fire-code"Type X drywall. See Detail A Self C ing - - elf Closing Door rr c� 3 8 if) Class ABC Doors w dges of Railing Top M 7. Insulation in the existing walls and ceiling areas are to remain undisturbed. CID Fire Extinguisher 5'-0" 8. Resilient floor tiles(selected by the owner) are to be installed throughout Existing Door 2 1 ed er Boar El ❑ ( ) g the Kitchen and Serving areas. 2 way Self Closing Door with Window 3��^ __ Q tered to Wal . 'U� F1 ❑ 4 ❑ ❑ 4 ❑ Employee Only Sign on Door i`� ,'i $" alv Bolts 16 9. All bathrooms must be ICC/ANSI compliant. ! `� ,� ! C Staggere ! ` ' ! U Building Occupancy Load F]__F1 4 X,\ N to 0 3'-3" AFFH VSD AS NOTED Wood Floor in Dinin Replace T-xisting Door i ister Existin ist w Dining Room-35 DATE: � B.P.# Handicap Ramp Kitchen and Entry Area-5 F1 ons Similar toy 5'_0" rade 2nd Floor Apartment-2 35 Seat Front Entry Door New Hand Rail FEE: > BY: EF1 Dining 10_31" New 12"0 Poured Concrete Total-42NOTIFY BUILDING DEPARTMENT AT Details onotube Footings Under 765-1802 8 AM TO ` P��! FOR THE Room Class ABC Existing Support Columns Scale: 1" = 1'-0�� Occupancy Classifications FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED ❑ Fire Extinguisher YWiden Existing Deck by 14 ," Restaurant-Assembly Group B FOR POURED CONCRETE 21 2 Above Grade Apartment-Residential Group R-3 2. ROUGH - FRAMING & PLUMBING 1:11:1F] El Handicap Ramp Details 3. INSULATION 4 ❑ 4 4 4 4 Construction Type V-A 4. FINAL CONSTRUCTION MUST ❑ F1 ❑ ❑ ❑ ❑ ❑ ❑ Scale: 1/4" = 1'-0" BE COMPLETE FOR C.O. Floor Areas ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW 1st Floor- 1,409 sf YORK STATE. NOT RESPONSIBLE FOR 1 st Floor Plan 2nd Floor-769 sf DESIGN OR CONSTRUCTION ERRORS. Widen Existing Deck by 14" Cellar- 1,370 sf 8'-011 COMPLY WITH ALL C E VN OF •� ►�� .� CODES AS REQUIRED AND CONDITIONS OF UP (ICO Door El Class ABC F Fire (Extinguisher IIt�SI�ECT�o � 1��Natural Gas Meters Class ABC 0 OPENING Ire Extinguisher •" �� Bottom of Stair above and O Walls are to be covered with $" Fire Rated Sheetrock OCCUPANCY OR See Detail A Below QF_ t USE IS UNLAWFUL New mmercial Water d ntial W ter PLU R CERTIFICATION WITHOUT CERTIFICATL Heater eater ON -AD CONTENT BEFORE OF OCCUPANCY C I TIFICATE OF OCCUPANG� • - SOLDER USED 1N WATER ❑ ELECTRICAL SUPPLY SYSTEM CANN0- INSPECTIONi REOUIRFD Sealed and Painted Concrete Sla Dining Room i EXCEED 2/10 OF 1% L F-4 ') ❑ ! ! Fire Leparation ! ! required as per STORE ROOM /urnaces L J NYS Code 2nd Floor I�a ALL PLUMBING WASTE. V ( &WATER LINES NEED;. All exterior lighting Total 769 sf 6 d TING EEF<fiE COVERING estaurant Electric Panel m�� installed,replaces] or ! I 3o i i repaired shall conform to Chapter 172 estaurant Electric Meter i i H t of the Town Code New Water Heater L Apartment Electric Meter * Rheem Model HE55-160 r� ub Water RPZ COOLER Kitchen * Natural Gas 5 ° 0 * 55 Gallon * 160,000 BTU/Hour Input IC I' I n ❑ ,8 �8 Co ❑ MAR 1 0 202 t �_, BUILDING utp7: Cellar Plan 0 -z3ul �r 00TH01,P 2x6 Studs Fire Stopped Living/Bed Roo Q Q O 16" Bedroom O O t � vi ork- /8 Thick Fire Rated Gypsum Board ' ( 2nd Floor Plan6L� S " 4A 1. Nail heads-Exposed or covered with joint compound. . w, ' CAM r 2. Joints-Exposed or covered with fiber tape and joint compound. 3. Wall board nailed 7"OC with 6d cement coated nails 1-7/8"long,0.0915 shank diam, 1/4"diam heads. �/ A(I � dj// `� � ]ntsHes' 4. Wallboard,Gypsum-5/8"thick,two layers applied either horizontally or vertically. Inner layer attached to A I 'f c r U, studs with the 1-7/8"long nails spaced 7"OC. Outer layer attached to studs over inner layer with the 2-3/8"long nails spaced 8"o.c. Vertical joints located over studs. All joints in face layers staggered with joints in base Scale: 1/4" = V-101' Condon Engineering, C 1 l� layers. Joints of each base layer offset with joints of base layer on opposite side. Plans are prepared by Condon Engineering,P.C. It is a violation of the New Yak State Education P.C. P o o ka b e rry Cafe S h a O Law,Article 145,Section 7209,for an person unless actin under the direction of a licensed Drawn by : JJC Usi n No. 0305 -1 Hour Wall Detail Professional Engineer,Architect,or LanSurveyor,to alter ny item in anyway.If an item bearing Y 1755 Sigsbee Road 1140 Pike Street This is the horizontal assemblythe seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Mattituek New York 11952aoa v NYS � Land Surveyor shall affix to the item his/her seal and the notation'Attered by'followed by his/her � Mattituek, New York between the R-3 and B Occupancies signature and the date of such alterations,and a specific description of the alteration. Date : 3-9-2022 (631) 298-1986 Roof Mounted Exhaust Fan \ ��,manhole / Leaching Pool �\ / 100 x 6' Deep FRYER GUARD SPLASH \ I — GUARg/ � rY J Sanitary Design UP \ DN. o O 02 11 M Restaurant 35 seats Class K 1 ,' I 12 �/ \ \ 2nd Floor Apartment Fire Extinguisher 1 `� ,' 0 / 07II 05 0� "-- -1 -- SPLASH-__0 I I EQUIPMENT SCHEDULE(y) 4'-0I Grease 1 u id 1 GUARD N a I NOM QTY EQUIPMENT CATEGORY MANUFACTURER MODEL NUMBER REMARKSNT 6Q"_ _ 1 _ 1 _ __ PLA H I O1 1 EXHAUST HOOD W FIRE PROTECTION ECON—AIR �Tear*ance 1 —— &— 10 0 GUA D / ECON_ AIR \ ` Clearance 29 28 0 18 21 19 `\ / 01B 1 EXHAUST FAN AUST D CONTROL PANEL ECON—AIR \ _ 01C 1 M.0�, AN Reslllent Floor Tiles � / F ECON—AIR \ J / \a �/ Throughout Kitche t6 \ / -�� 02 1 OVEN—STEAMER, COMBINATION, ELEC. RATIONAL USA ICOMBI PRO 10—HALF G Ladies Lay. Ens LdV and Serving Areas 23 23 / / \ Distribution 03 1 FRYER, DEEP FAT, GAS VULCAN 1VEG35M \ Leaching Pool 04 1 CHARBROILER, COUNTERTOP, GAS STAR MANUFACTURING 6024CBF 3' " 1-0,1 O 15 I 100 x 6' Deep 05 1 EQUIPMENT STAND BEVERAGE—AIR WTRCS-64-1 elf Closing Door Self 1 sing 1 06 1 HOT PLATE, GAS STAR MANUFACTURING 806H Door " � 07 1 CHEESE MELTER, GAS GARLAND GIBCM36 1 / 08 / SPARE NO. \ \ 10 1 HAND SINK, WALL MOUNT SAPPHIRE MANUFACTURING SMHS-02—D \ 11 1 SINK, NSF, 1 COMP, SAPPHIRE MANUFACTURING SMS1821 2 way Self Closing Door with Window _______ / `\ / 12 1 THREE COMP'T. SINK SAPPHIRE MANUFACTURING SMS-3-1821L 4 Employee Onl Sign on Door �` '� 13 1 CLEAN DRAINBOARD WALL MTD. 4 y g 1 ` 1 / \ 13A 1 FAUCET, WALL MOUNT T do S BRASS B-0231 F] i 1 4 El I `� ,� 14 1 MOP SINK KROWNE MS-1818 1 X 1 9f El / \ \ Leachin 001 14A 1 FAUCET, WALL MOUNT T do S BRASS 8-06656STR I , I M g 148 1 MOP HANGER ADVANCE K-242 Wood Floor in Dinin I ��/ \�� I 100 X 6' D�ep 15 1 DISHTABLE, UNDERCOUNTER SAPPHIRE MANUFACTURING SMUDT-60R Replace EXisting Door' I / 15A 1 PRE—RINSE FAUCET, WALL MOUNT T do S BRASS B-0133—B one Similar to th \ 16 1 WAREWASHER, UNDERCOUNTER JACKSON WWS DISHSTAR HT Front Entry Door \ / 17 1 DISHTABLE, SORTING SHELF SAPPHIRE MANUFACTURING SMSR21 EF1 18 1 REFRIGERATOR, SANDWICH PREP TRUE MFG. TSSU7224 MBHC / 19 1 HOT FOOD COUNTER VOLLRATH 38103 -�� 20 1 DOUBLE OVERSHELF \ _ I ' 21 1 WARMER, FOOD OVERHEAD HATCO — GRAH-84 0 22 1 REFRIGERATOR, REACH—IN TRUE MFG. T-35—HC 22A 1 FREEZER, REACH—IN TRUE MFG. — T-23F-2—HC IFI4 4 4 4 4 $ tic Tank 23 1 PREP. TABLE SAPPHIRE MANUFACTURING C1Q� X 6' 23A 2 WALL SHELF 23B / SPARE NO. Deep \ Leaching Pool 24 / SPARE NO. / 10Q1 x 6 Deep 25 / SPARE NO. 1st Floor Plan 26 / SPARE NO. 27 / SPARE NO. 28 1 PREP. TABLE SAPPHIRE MANUFACTURING 29 1 HAND SINK SAPPHIRE MANUFACTURING 30 1 WALK—IN COOLER RATER m� 308 1 CONDENSING UP 308 1 CONDENSING UNIT LOCKERS Roof 31 1 WALK-IN SHELVING (N.I.C. BY 32 1 ICE MAKER W/O BIN SCOTSMAN C0322MA-1 OTHERS) 32A 1 BIN, ICE SCOTSMAN B322S atural Gas Meters 33 2 ICONDENSATE EVAPORATER 34 1 1 REFRIGERATOR, WORK TOP TRUE MFG. — TWT-48—HC 4"0 PVC __1 0 0 0 0 0 QF_ 2"0 PVC—/ New Commercial Waterj dE ntial W ter Dish Heater Heater Table 3"0 Pvc Refrig. Freezer Sandwich Prep 3 Compartment Undercounter Mop Sink Hand Wash Refrig. 1 Compartment Sink Hand Wash #02 #16 #15 #14 Hand Wash -T Sink #22 #22A #18 Sink P t7 Sink #10 #10 Oven Dish � � Sink Sealed and Painted Concrete Sla "0 Pvc SteamerWasher# 2 3"0 PVC---.*' 2"PVC #11 STORE ROOM /urnaces Sink #14 2"CI 2"CI Sink Toilet Toilet Sink 2"Cl 2"CI 2"CI 2"CI 2"CI \�\ 2"CI 2"C 2"Cl 2"Cl 2"Cl F � CO To Grease Trap 2°Pvc 2"P 3"0 PVC 2"PVC 3"0 PVC //Restaurant Electric Panel 3"0 PVC \_3" O PVC 30 CO Ladies Lay. Mens Lay. JC Lay. To Septic Tank estaurant Electric Meter "0 PVC Waste Plumbing Riser Plan Apartment Electric Meter 32 ub Water R'PZ (STORERM. WALK-IN FIN. HUNG SHELVES COOLER 0 CLG. N.I.C.BY o 33 33 ABOVE) OTHERS) P . 1848 1848 1848 IW O , ..k,•. C'm 't R �' Cellar Plan 1 „y.,�. '... New Water Heater ' 10V r. �; * Rheem Model HE55-160 * Natural Gas * 55 Gallon Scale: 1/4" = 1'-0' Condon Engineering, P.C. Pook r * 160,000 BTU/Hour Input abe ry Cafe Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Drawn by : JJC 1755 Si sbee Road 140 Pike Street Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing 9 the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Mattituck, New York 11952 Mattituck New York Land Surveyor shall affix to the item his/her seal and the notation'Altered by'followed by his/her Date : 3-9-2022 signature and the date of such alterations,and a specific description of the alteration. (631) 298-1986 Walls and Stairs above are to be covered with$"Fire b� Rated Sheetrock 3'-0" 3'-0" -Existing Doors 1. All work material and equipment shall be in accordance with the 2020 New UP stn D o 8,-9„ York State Uniform Building Code, and the ICC/ANSI Al 17.1-2009. Landing Currently 8 4'Above Grade 2. All work to be performed by licensed and insured Contractors and Sub- Lift Landing to 12"Above Grade contractors. a i \\ /' Fire Extinguisher `� ,' After Raising Landing _(bN o 3. Contractor must carry General Liability Insurance and Workman's 1 I I 21 2'- 12"= 9.5" Ris "' New 2"fd Stainless Compensation as specified by State and Local laws. 0.._� i X i '-0"—�--t M = O 4'-01 i �' �� i 9.5"/131"= 1" in 13.79"Slope Steel Handrail ' \ 4. Site is to be maintained in an orderly manner, left clean of debris and dge of Deck Surface broom clean upon completion. Contractor is responsible for the removal of / i ❑' i \ ❑' C.0 i site debris. 6Q" / - i CTear�ance - -- -6�0'r-�-- 0 5. All new walls or existing walls and ceiling areas that have been stripped of Clearance After Raising Landing existing finishes are to be covered with 8"thick"fire-code"Type X drywall \ , / 2"/146"= 1" in 12.167"Slope in accordance with UL Design No. U305. See Detail A Ladies Lay. ins -L-a�V `'�� 6. The walls and surface area above the stairs from the cellar are to be 1 st U_ (V (V floor and the walls and ceiling at the door to the exterior are to be covered 3' ,-0„ Self C inFx O � � with 5'thick"fire-code"Type X drywall. See Detail A elf Closing Door g m c� C0 3141 Doors w dges of Railing Top 7. Insulation in the existing walls and ceiling areas are to remain undisturbed. C) Class ABC ;� " Fire Extinguisher 5'-0" 8. Resilient floor tiles (selected by the owner) are to be installed throughout Existing Door (2) 1 edger Boar 4 F1 F] X�,. --- Replace isti Door C2 tered to Wall the Kitchen and Serving areas. ne Simil to 8" alv Bolts 16" 9. All bathrooms must be ICC/ANSI compliant. � ��� i Front Ent Do C Staggered 4 U - - Building Occupancy Load Countertop No Seat � ��"�\ i x 0 1; � N Zo Wood Floor in Dinin �� �� i ister Existing ist x Dining Room-35 2 way Self Closing Door with Window �� �� 5'-0„ 9 w rade Handicap Ramp Kitchen and Entry Area-5 35 Seat Employee Only Sign on Door New Hand Rail 2nd Floor Apartment-2 EF1 Dining 2.. New 12"0 Poured Concrete Details Total-42 10-3- Room Class ABC onotugbe Footings Columns Existing Su Scale: 1" - 1'-0" Occupancy Classifications Fire Extinguisher Widen Existing Deck by 14" Restaurant-Assembly Group B 21 2"Above Grade Apartment-Residential Group R-3 4 1EF] ❑ 4 F1 4 1:1 114 1:1Handicap Ramp Details Construction Type V-A [:] Scale: 1/4" = 1'-0" Floor Areas 1 st Floor- 1,409 sf 1 st Floor Plan 2nd Floor-769 sf YWiden Existing Deck by 14" Cellar- 1,370 sf 8'-0" UP Class ABC ilco Door Fire Extinguisher 11 10 atural Gas Meters Class ABC re Extinguisher O Bottom of Stair above and Walls are to be covered with $" Fire Rated Sheetrock See Detail A Below 0 New Commercial Water dE ntial W ter Heater F eater e i --------i ❑ i i ❑� Dining Room j ealed and Painted Concrete Sla I i I i I i - /urnaces L_-- STORE ROOM 2nd Floor Total 769 sf estaurant Electric Panel 3o i i estaurant Electric Meter New Water Heater/Apartment Electric Meter * Rheem Model HE55-160 ub Water RPZ CWALK-INOOLER " Natural Gas Kitchen " 55 Gallon n � 160,000 BTU/Hour Input a 1848 1848 ! 1848 W ❑ ' e Cellar Plan 2x6 Studs Fire Stopped Living/Bed Roo Q Q O 16" Bedroom O O /8"Thick Fire Rated Gypsum Board 2nd Floor Plan 1. Nail heads-Exposed or covered with joint compound. \\\ . 2. Joints-Exposed or covered with fiber tape and joint compound. - 3. Wall board nailed 7"OC with 6d cement coated nails 1-7/8"long,0.0915 shank diam,1/4"diam heads. 4. Wallboard,Gypsum-5/8"thick,two layers applied either horizontally or vertically. Inner layer attached to studs with the 1-7/8"long nails spaced 7"OC. Outer layer attached to studs over inner layer with the 2-3/8"long nails spaced 8"o.c. Vertical joints located over studs. All joints in face layers staggered with joints in base Scale: 1/4" = V-0' Condon Engineering, P.C. layers. Joints of each base layer offset with joints of base layer on opposite side. P o o ka b e rry Cafe Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education A UL Desi n NO. 0305 -1 Hour Wall Detail Law,Article 145,section 72o9,for any person unless acting under the direction of a licensed Drawn by : JJC Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing 1755 Sigsbee Road 140 Pike Street This is the horizontal assembly the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Mattituck New York 11952 between the R-3 and B Occupancies Mattituck New York Land Surveyor shall affix to the item his/her seal and the notation'Altered by'followed by his/her Date : 4-14-2022 signature and the date of such alterations,and a specific description of the alteration. (631) 298-1986 V� Roof Mounted Z-- Exhaust Exhaust Fan --imJlanhole0 / \ I Leaching Pool FEB 2 4 202,E lass K /\ 100 x 6' Deep Desk n ai / �+ a�m.r. �./ Fire EXtin wisher FRYER GUARD SPLASH GUAR \ Sanitary Design UP DN. o 0S Staff Only Restaurant 35 seats ri Z1, 12 / 2nd Floor Apartment Open to Bel �' 0 on Conce I i '_0��—� os 1 13 \ I O -- S ace '-0"o �'' o 4'-0'7 I ' ` 1 13 Grease Trap F -1-- - -+- SPLASH i in _ _ 100 x 5' Liquid eep EQUIPMENT SCHEDULE I / ° GUARD ° I I \ / ITLM EQUIPMENT Stanchions 61„ I O' I �° N I NO QTY EQUIPMENT CATEGORY MANUFACTURER MODEL NUMBER REMARKS $e rating Staff\ -Q - / _- _ _- PLA H 01 1 EXHAUST HOOD W/ FIRE PROTECTION ECON-AIR Area from Public �Teararlce - -- -6'0— 29 28 ,$ 19 10 GUA D / \ / OtA 1 EXHAUST HOOD CONTROL PANEL ECON-AIR Area / Clearance / 0 21 17 01B 1 EXHAUST FAN ECON—AIR Resilient Floor Tiles \/ OIC 1 M.U.A. FAN ECON-AIR ---Throughout Kitche 02 1 OVEN-STEAMER, COMBINATION, ELEC. RATIONAL USA ICOMBI PRO 10-HALF G Ladies Lay. Law and Serving Areas 3 23 / \ Distribution 03 1 FRYER, DEEP FAT, GAS VULCAN 1VEG35M eaching Pool 04 1 CHARBROILER, COUNTERTOP, GAS STAR MANUFACTURING 6024CBF 3' " '-0" 0 15 I 100 x 6' Deep 05 1 EQUIPMENT STAND BEVERAGE-AIR WTRCS-64-1 elf Closing Door Self I sing 11 7 06 1 HOT PLATE, GAS STAR MANUFACTURING 806H Door 07 1 CHEESE MELTER, GAS GARLAND GIBCM36 1 �� 08 / SPARE N0. \ / 10 1 HAND SINK, WALL MOUNT SAPPHIRE MANUFACTURING SMHS-02-D Fire Extinguisher \ / \ 11 1 SINK, NSF, 1 COMP, SAPPHIRE MANUFACTURING SMS1821 Self Ll 12 1 THREE COMP T. SINK SAPPHIRE MANUFACTURING SMS-3-1821 L F1 e Extinguisher 13 1 CLEAN DRAINBOARD WALL MTD. 4 4 Employee Only Sign on Doo I `�\ �,' 7 13A 1 FAUCET, WALL MOUNT T & S BRASS B-0231 �F] r] r] F1 Fire Ixtln \ f O 14 1 MOP SINK KROWNE MS-1818 4 Countertop No Seat g "'� \ I 14A 1 FAUCET, WALL MOUNT T & S BRASS B-0665BSTR Leaching 001 I 14B 1 MOP HANGER ADVANCE K-242 —" �� I 100 x 6' D ep ___ 15 1 DISHTABLE, UNDERCOUNTER SAPPHIRE MANUFACTURING SMUDT-60R I Replac'.e-ExistingDoo�\td 15A - one Similar to th � 5 1 PRE RINSE FAUCET, WALL MOUNT T & S BRASS B-0133_B 16 1 WAREWASHER, UNDERCOUNTER JACKSON WWS DISHSTAR HT Wood Floor in Dinin Front Entry Door l \ / 17 1 DISHTABLE, SORTING SHELF SAPPHIRE MANUFACTURING SMSR21 \ 18 1 REFRIGERATOR, SANDWICH PREP TRUE MFG. TSSU7224 MBHC EF1 / \ \ / 19 1 HOT FOOD COUNTER VOLLRATH 38103 / 20 1 DOUBLE OVERSHELF 21 1 1 j WARMER, FOOD OVERHEAD HATCO GRAH-84 `- 22 1 REFRIGERATOR, REACH-IN TRUE MFG. - T-35-HC 1 FREEZER, 4 El 4 4 4 4 S tic Tank \ 23A 1 REP.TABLE CH-IN SAPPHIRE MANUFACTURING T-23F-2-HC El 00 X 6' 238 2 WALL SHELF 1:1 Deep \ / Leaching Pool 238 SPARE NO. 24 / SPARE NO. / 100 x 6' Deep 25 / SPARE NO. 1st Floor Plan 26 / SPARE NO. 27 / SPARE NO. 28 1 PREP. TABLE SAPPHIRE MANUFACTURING LOCKERS 29 1 HAND SINK SAPPHIRE MANUFACTURING 30 1 WALK—IN COOLER OTH30A 1 EVAPORATER Exit--- (�E 308 1 CONDENSING UNIT WLJ Illuminated Exit Sig 1�� Roof 31 1 WALK SHELVING UP—[ 24'-72 32 1 ICE MAKER W/0 BIN SCOTSMAN C0322MA-1 32A 1 JBIN, ICE SCOTSMAN 8322S atural Gas Meters 33 2 CONDENSATE EVAPORATER 34 1 REFRIGERATOR, WORK TOP TRUE MFG. - TWT-48-HC 41.0 PVC ew C m\`�Cial Water Residertial Water ea H ater Dish Refri Freezer Sandwich Prep 3 Compartment Table g. Undercounter Mop Sink ao 3"0 PVC 2"0 PVC Refrig. Sink Hand Wash 1 Compartment Hand Wash #02 #16 #15 #14 Hand Wash Sink #22 #22A #18 Sink y7 I Sink #10 #10 Oven Dish � � Sink Sealed and Painted Concrete Sla "0 Pvc SteamerWasher Furnace # 2 3"0 PVC--' 2„PVC_ #11 Y-\ Y Y Y STORE ROOM Sink Sink Urinal 2" Cl 2"Cl 2"Cl 2"Clr\~'21, CI 2"Cl 2" Cl ��2"Cl 2"C 2"CI 2"CI 2"Cl Toilet Toilet CO To Grease Trap mergency Light 0T 0 2"P 3"0 PVC 3"0 PVC 2„PVC 3"0 PVC \_3"0 PVC estaurant Electric Panel 30 CO To Septic Tank Ladies Lay. Mens Lay. estaurant Electric Meter E) ° 3"0 PVC 3"0 PVC " PVC ❑= Waste Plumbing Riser Plan Apartment Electric Meter aC3 ector Pumub Water RPZ (STORERM. WALK-IN Staff Lay. j p 2„PVC(FIN. HUNG SHELVES 33 COOLER 0 CLG. N.I.C.BY Toilet Sink Urinal 3"0 PVC PSE OF NES, ABOVE) OTHERS) U rina a 5� Xa , cc4,,0 0 J0_2„PVC a' "" y 1848 1848 1848 II ' 3'0 PVC , Staff Lay. 3"0 PVC1"' a nisi r � Cellar Plan 684 y�C t New Bathroom will comply Ejector Pum ��SSIONA�' New Water Heater ith ICC/ANSI A117.1 2009 requirements. * Rheem Model HE55-160 * Natural Gas * 55 Gallon Scale: 1/4" = 1'-0' Condon Engineering, P.C. * 160,000 BTU/Hour Input Pookaberry Cafe Plans are prepared by Condon Engineering,P.C. It is a violation of the New Yak State Education ng Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Drawn by : JJC Professional Engineer,Architect,or land Surveyor,to alter any item in anyway.If an item bearing 1755 Sigsbee Road 140 Pike Street the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Mattituek, New York 11952 Mattituek New York Land Surveyor shall affix to the item his/her seal and the notation'Altered by'followed by his/her Date : 2-24-2023 631 298-1986 signature and the date of such alterations,and a specific description of the alteration.