Loading...
HomeMy WebLinkAbout49314-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT ` TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 49314 Date: 5/30/2023 Permission is hereby granted to Adams, Jason 382 Van Brunt St Brook) n, NY 11231 To: construct additions and alterations to existing single-family dwelling as applied for. At premises located at: 1650 Meda Ave, Mattituck SCTM # 473889 Sec/Block/Lot# 113.-11-11 Pursuant to application dated 5/12/2023 and approved by the Building Inspector. To expire on 11/28/2024. Fees; SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $484.00 CO-ADDITION TO DWELLING $50.00 Total: $534.00 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 � " Telephone(631) 765-1802 Fax(631) 765-9502 https:l/www.s+ uthhc ldlc wnn Date Recelved APPLICATION FOR BUILDING PERMIT J Y For Office Use Only t r PERMIT NO. Building Inspector: Applications and forms must be filled out in their entirety.Incomplete MAY 1 2 2023 applications will not be accepted. Where the Applicant Is not the owner,an Owner's Authorization form(Page 2)shall be completed. " r Date:May 16,2023 OWNER(S)OF PROPERTY: I Name:Jason Adams & Eileen Shannon SCTM#1000-113-11-11 Project Address:1650 Meday Ave, Mattituck, NY 11952 Phone#:646-772-5336 1Email:jasonpeteradams@gmaii.com Mailing Address:382 Van Brunt St., Brooklyn, NY 11231 CONTACT PERSON: Name:Jason Adams Mailing Address:382 Van Brunt St., Brooklyn, NY Phone#:646-772-5336 Email:jasonpeteradams@gmail.com DESIGN PROFESSIONAL INFORMATION: Name:Michael Schmitt Architect, P.C. Mailing Address:30 Vesey St.,PH, New York, NY 10007 Phone#:212-477-0906 Email:ms@studiomsa.com CONTRACTORINFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure RAddition (®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $150,000 Will the lot be re-graded? ❑Yes IQ No Will excess fill be removed from premises? ❑Yes @No 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R40 this property? ❑Yes WNo IF YES,PROVIDE A COPY. W Cheek Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold.Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of bulctings. additions.alterations or for removal or demolition as herein described.The applicant gees to comply with all applicable laws,crI building code, housing code andihatlons and to admit authorized Inspectors on premissa and In building(s)for necessary Inspections.False statements made herein are punishable as a Class A m sd'omsmw pursuer,to Section 210.45 of the New York State Penal law. Application Submitted By(print name):Jason Adams ❑Authorized Agent INOwner Signature of Applicant: Da 16,2023 STATE OF NEW YORK) I ti�cI41il ' " irrJ � rrk� � � SS: COUNTY OF MCtLIlULLID ) ',s��� *� h One Jason Adamsmw being duly s d that(s)he is the applicant (Name of individual signing contract)above n i er, x (S)he is the Owner (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 6th day of May 20 23 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 S ss� 0- o :� N O .cO / S.C.T.M. NO. DISTRICT: 1000 SECTION.• V� 113 BLOCK: 11 LOT(S): Q Z E 00- 0 r a) n ^' ``^/ r.-I Z U (V : . GL= F GRAVEL pAV MEN7 ' AVcoo ) ATENUE EL 2,5.3 DL--AjL CL 24.2 .'b K1T('.*.** HE '1kN' ADDITIONa BLUE STONE .4 e e,4 ° DRNEWAY a' LILA U.P e N73*05'00"E A X50.00 a • • a CONC. e •d EL' 25.9 • . • . MON, EL 26.0 e AT CORN 1650 IM E DAY AVE N U E a ' t12 a �_ �` °' - ate, ��l G MATTOITUCK NY 11952 , A w . a . I , , E!_ 26,8 •• d 90 DRY WELL W �Q 8'DlAxB'DEEP ® > Z cu I i EL 27.5 1f a` LATE > �� r EL.27.5:: STOOP Q = DRAWING LIST , o �,! o ° d' , ...5 1'' . ENC(„05ED W ! t Y f - _ SHT DESCRIPTION DATE •...:�:;:� :;.:Q �+�Et: i ' 38.6 o ~ ,,:'• Q o.1:6.50 .... W}OOD . � �� •d• .,r.'e,.•rr..i: r:',•..'.: '' •: +•+. PATIO `0 ST-100.00 DRAWING LIST & SURVEY 3/17/2023 ! "'' :•;�;':°4: '- FF EIS . 0$ 9, p EL: 28.4LO ,,.:.. SD-100.00 STORM WATER DRAINAGE 3/17/2023 EL 28.8 "' . '�•� " ;•,•::'�5:E3r;' I GATE ' " 10' WIDE 25. 1 ' :1 s.6' 8.0' z A-100.00 SITE PLAN 3/17/2023 / OD S WO DECK HR ••• . . w RIGHT OF WAY R - ' .�' C� A-101.00 DEMO PLAN 3/17/2023 a ;r;,;; ... •• SPA , 8x8.5 ::�: "'"4 1 t� �GARAGE: 8 8x8 N t- PQ U A-102.00 FLOOR PLAN 3/17/2023 - "�ATEEL(29.5 �-. cn z A-102.10 MEZZANINE PLAN 3/17/2023 EL 25.5 CNC. WALL _. . ' . . • • ( - 0 P f 0 LOT 27 oa A-103.00 ROOF PLAN 3/17/2023 ° "' I `L 0) 6 : P/ O LOT 28 ( 00 °' I A-104.00 FOUNDATION PLAN 3/17/2023 cV EL 31.3 A-104.10 1ST FLOOR FRAMING PLAN 3/17/2023 � S71o32'2Q"W 1 I 150.20 c,o A-104.20 MEZZANINE AND ROOF FRAMING PLAN 3/17/2023 N 00 I rn!zh . Fla �- A-104.30 WALL FRAMING DETAILS 3/17/2023 cV I I A-105.00 FOUNDATION DETAILS 3/17/2023 O I ' 41Ar 17 2723 0CD, 0 i 41 SUILOINGDEpT A-106.00 EXTERIOR WALL SECTIONS 3/17/2023 CL , I TC"u"OFS0I)TH LD A-106.10 EXTERIOR WALL SECTIONS 3/17/2023 I A-200.00 ELEVATIONS 3/17/2023 P-100.00 PLUMBING PLAN 3/17/2023 M-100.00 MECHANICAL PLAN 3/17/2023 O E-100.00 ELECTRICAL PLAN 3/17/2023 U CO CO � 0Ap (a) LU FINAL SURVEY 04-15-21 THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL z ~ `r LOCA 7rON5 SHOWN ARE FROM FIELD OBSERVATIONS ✓:� 1` '`� '` " .• a`n z REVISED 04-23-16 AND OR DATA OBTAINED FROM OTHERS. Q ^ AREA: 14,793.84 S.F. OR 0.34 ACRES ELEVA77ON DATUM: NA_vD88 3'dc• .i �- �..___-- +(p _a Q a UNAUTHORIZED ALTERATION OR ADD1770N TO 7Nl5 SUR t/EY ISA V/OLATTON OF SECTION 7209 OF 774E NEW YORK STATE EDUCA77ON LAW, COPIES OF THIS SURVEY �` �-y 0- MAP NOT BEARING THE LAND SURVEYOR'S EM8OSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN S ` z�r42 _10 O ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS777UT70N Q LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INS777UTlON, GUARANTEES ARE NOT TRANSFERABLE. 174E OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE N07INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE CREC77ON OF FENCES, ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS EASEMENTS AND/OR SUBSURFACE SIRU&yUURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON 774E PREMISES AT THE 77ME OF SURVEY MARCH 17, 2023 SURVEY OF: PART OF LOTS 26,27 & 28 CERTIFIED TO: JASON ADAMS; MAP OF: MAP OF LOTS LOCATED AT EILEEN SHANNON; MATTITUCK L.I. PROPERTY OF WM. B. COOLING o FILED: MAY 10, 1921 AS #745 LU SITUATED AT: MATTITUCK TOWN OF: SOUTHOLD KENNETH M WO'YCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK Professional Land Surveying and Design o AUGUST 16, 2016 t , P.D. Box 153 Aquebogue, New York 11931 w FILE # 23-164 SCALE: 1 "=20' DATE: DEC. 18, 2003 PHONE (631)296--1588 rAX (631) 298-•1568 N.T.S. N.Y.S. LISC. NO. 050882 maintaining the records of Robert J. 8ennesay de Kenneth M. Royabuk W TITLE SHT &SURVEY ST- 1 00 . 00 U o- o C) (Y) o o o U :3 r- L a) Z cu -leL U O OQom, ..c a)�•, Z U N 24" Cl FRAME AND PERF DRAIN COVER N 8' DIAMETER DRYWELL, 8'-0" DEEP 4 DRAIN PIPES TO DRYWELL SEE SITE PLAN FOR LOCATION REFRIG COOKTOP OVEN W Q Z TRASH DW Q U 0 EXISTING STRUCTURE W ~ 2 �-- U-) Q Cfl 73 KITCHEN I I I� 4" PVC RISER AND LEADER A BATH BEDROOM-3 0 Fl 4" PVC RISER AND LEADER ADAPTER CONNE T TO EXISTING 4" PVC RISER AND LEADER AD TER WOOD PATIO o O HOT TUB U U) (.0 Q EXISTING Q � GARAGE0 U) W Z Q ti Q 3: ZtiQ O � � W Q � CL -� Z O 0 MARCH 17, 2023 Z U W SITE DRAINAGE PLAN e;5;�• ` 1 SCALE: 1/4"= 1'-0" ���,,,� / �+`�a o AUGUST 16, 2016 U co 1/411 -011 i. 1'y 17,747 t STORM WATER DRAINAGE SD- 1 00 . 00 U no 0 � o :�­ (1) o .Ei= o U � � L W Z E c 00- O U) cu � N Z U CV MEDAY A N 7303510011 E 150.000' C)EL 26.0 _ _ _ ---_.__ - - - PITCH - ------ - ._ I I I I PITCH DRYWELL I 8' DIAMETER X 8' DEEP DI (25.0) Q z I I � / 35.2 38.4 355 35 FRONT YARD SETBACK 5 FR NT YARD SETBACK I I CW c _ 23.6 �z L 27.5 I O I EL 27.5 - G U-) c N < 1� I --------- - -----_ 19.7 EL 27.0 (D�-- �-- O PROPOSED WOOD DECK 4.4 - �-- EL 28.8 0 35.2 PROPSED TWO-STORY I ADDITION ENCLOSED PORCH OLij TO BE DEMOLISHED 16.9 /Al EXISTING STRUCTURE co 1,850 SF I EL 27.5 i LmJ z 14.5 FFL EL 28.9 I I I / TOW p i I EL 28.8 CV ui < I10.6 18.5 35.2 co 25.3 EL 28.8 35.0 O PROPOSED I I L1.1 ONE-STORY O EXISTING f -{ ADDITION LO$8 I M + i + - GA EA ORAGF� ... r + + + iL 28.8. ............. ;:;::::::::::'� ..:...:..... PROPOSED CONC. .. .. ��• EL 3 . _ 9.0 Cfl ............ .. .... .. .......... ...................... -E -� -{- -} -�- -{ -{- .•..- :::.::..:.::......:.:.:.:.:.:.:.:+:.::::: :. PR�POSED OOD D K:.:::':: I 0i + + + r-- 22. .......................................... ................. L 28 8 TOW + + + + -I- >I- ::::::: :-f- SPA+ + :::: .....'.. '::::::::+:: EL X2.0 + + + + + + (n I IV. EL 30.5 35.2 2E I ........ OW + + + + + I -}� I + + + + + EL 32.4 + + + + f EL 31.1 l OUTDOOR SH6WER EL 31.1 + + _4PORTION-OF DEC(CONSI�UCTED_PELOW GRAD + + + + + + + + + + + + + + + •2 + + + + + + + I + + +EL 31. + + + + + + �IIIALL-STOW EL1.0XISTING CONC RET NI + + + + + + + + + I + _ + + + + + EL 3+1.5 + + + + + + + + + + + + + -f+ + Qco S 7103212011 W 150.200' z `t ti Q 3: Z OOcflw PY: 1 794 F OR , 33 A � � W CRE0 -, �. Z MAX PERMITTED LOT COVERAGE = 2,958.80 SF o TOTAL WITH PROPOSED ADDITIONS = 3,244 SF LESS PROPOSED DECK CONSTRUCTED BELOW GRADE 687 SF = TOTAL LOT COVERAGE OF 2,557 SF MAY 2 6 2023 A�, MARCH 17, 2023 MAY 17, 2023 Z O W A AUGUST 16, 2016 .,,.. y 1 : 10 ,tit$ • := "I w 177.0 J SITE PLAN A- 100 . 00 U � o 0 � o U � r- L ^ v' Q J_ --- a� Z c L -� O cu cu a) Z U N A REMOVE EXISTING CABINETS AND FIXTURES - - - - - - - - - - - - - - - - - - - - � II KI HEN EXISTING CHIMNEY LIVING ROOM L — I PORCH TO REMAIN (NO WORK) I I W n Z (- -1 - - - - - - - - - - - - - - - - - - -- I w B TH Il— JII I- - - - - - - - - - - - - - - - - - -� 2 I-- DEMOLISH EXISTING PORCH AND FOOTINGS I I II II I II II II II II II II II I UTILITY I I BEDROOM I I BEDROOM I I BEDROOM I REMOVE EXISTING FIXTURES II II II II II II I I II II I � 1 REMOVE EXISTING VINYL SIDING II II II EXISTING PROPANE TANK TO BE RELOCATED DEMOLITION NOTES I I BATH ENCLOSED (NO WORK) REMOVE EXISTING STUCCO WALL FINISH I I PATIO 1. REMOVE ALL PARTITIONS, DOORS, FIXTURES, ETC. INC=DICTATED BY ---------- OF PLAN II 2. REMOVE ALL FINISH FLOORING IN BEDROOMS 3. REMOVE ALL EXTERIOR SIDING BACK TO WALL SHEATHING AS INDICATED 4. REMOVE ALL DRYWALL AT EXTERIOR WALLS IN BEDROOMS 5. REMOVE SOFFIT AND FASCIA AT ALL AREAS OF SIDING REMOVAL DEMOLISH EXISTING COURTYARD WALLS AND FOOTINGS 6. NO STRUCTURAL ELEMENTS ARE TO BE REMOVED 7. ALL PLUMBING AND ELECTRICAL LINES, WHICH ARE TO BE REMOVED OR RELOCATED ARE TO BE '- — — — — — — — — — — — O CONCEALED PROPERLY AS PER CODE. �? 8. REMOVE AND PROPERLY TERMINATE ELECTRIC HEATERS IN BEDROOMS. U) Cfl 9. PROTECT ALL HEATING DUCTS FROM DUST INTRUSION. EXISTING STONE PATIO TO BE REMOVED . . Q M 10. ALL PLUMBING LINES TO BE CUT AND CAPPED AS REQUIRED. W 0 � @ REMOVE EXISTING VINYL SIDING Z ti o 3: Z ^ � O � (ow QCDa- z 0 U) a L AN: DEMOLITION 1 SCALE: 1/4"= 1'-0" ® MARCH 17, 2023 Z 0 5 w i ZA �,y, AUGUST 16 2016 uih 1/411 = 1'-0" -ko 1774 � DEMOLITION PLAN A- 101 . 00 U n- o � c ~o :� a) o AA 3 U O A105.00 A200.00 Q 6 U Z A106.10 E (Cf L U Q. �O .�------ 641 C0 O o O ��----' 6'-711 , 0.. N CU Z WOOD PATIO REFRIG W04 U N COOKTOP W04 OVEN/MV - A/ 11 77777777--J1 �t KITCHEN W03 I a DW LIVING I DINING ROOM `� 4 M (EXIST) 12'-0" -- A200.00 I 41-4Y8 11 5 2'-9" — 4'-6%" — 5'-9%" 4" 4 A106.01 A-106.10 W02 - -2- CL D LAUNDRY M DDERTO ZZM co co ' C co CL 2 71.911 C , Is A106.00 BATH Wol \ TYP OQ _ W � > Z Q BED-3 BED-2 MBR \ �' � w o Q UTLTY P, WALL TYPE cW I— B � G OWINDOW NUMBER DNQ DOOR NUMBER L AK (02 - • 1 C0 IONIZATION SMOKE DETECTOR & CARBON MONOXIDE ALARM DETECTOR GARAGE O A200.00 BATH WOOD PATIO _ (EXIST) WOOD PATIO O FLOOR PLAN O SCALE: 1/4"= V-0" DOOR SCHEDULE Generated by REScheck-Web Software HARDWARE Compliance Certificate SYM NAME HEIGHT WIDTH THICKNESS ACTION MAT'L SET NOTES Project 1650 Meday �' •� C MARVIN ELEVATE SERIES Ener Coder O U "NORTHFIELD"-SATIN NICKEL 9Y 2018 IECC WOOD-ULTREXELSPD12080, Location: Mattituck,New York —� A KITCHEN RO 8-0 RO 11-10 OXXO WOOD ULTREX PVD, HINGES-SATIN NICKEL �, h ` �. ^► PVD LOW E3,COLOR BARE WOOD x Construction Type: Single-family � N�c "EBONY" Project Type: Addition Climate Zone: 4 (5331 HDD) f I .t " M (D Permit Date: e- ,a- ry 11 PASSAGE SET AND THERMA-TRU PREHUNG Permit Number: ' (' Q B UTILTIY 7-0 2-8 1-3/4 OUT SWING - RH FIBERGLASS DEADBOLT FIBERGLASS DOOR AND FRAME y� . 17742 Q Q Construction Site: Owner/Agent: Designer/Contractor: Z y � L 1650 Meday Ave '"y�Q Z Q Mattituck,NY 11952 C BATH CLOSET 7-0 2-0 1-3/4" BI-FOLD SC TRACK AND KNOB PAINTED GENERAL NOTES: O Q w C-11 COAT CLOSET 7-0 2-6 1-3/8 BI-FOLD SC TRACK AND KNOB PAINTED Maximum SHG (n I- Compliance: C-12 LAUNDRY 7-0 4-0 1-3/8 TWIN SC KNOB AND CATCH PAINTED 1. ALL WORK TO COMPLY WITH 2018 IRC, NYS BUILDING CODE AND SOUTHOLD The%Better or Worse Than Code Index refects how close to compliance the home issbbased o code trade-off W u +M1µ+µ pW" - mw µ -ate Compliance: 7.0 Better Than Code Maximum UZ. 72 C:0.40 Your SHGC 0.19 Q /'1 a � 11 \ '`1J n ales TOWNCODE M DOES NOT provide an estimate of energy use or cost relative to a minimum-code home z Slab-on-grade tradeoffs are no longer considered in the LIA or performance compliance path in REScheck.Each stab-on-grade 0 D BATH 7-0 2-6 1-3/811 SWING SIC PRIVACY SET 5 JAM B S 4 2. COMBINATION SMOKE/CARBON MONOXIDE DETECTORS TO BE INSTALLED AS assembly in the specified climate zone must meet the minimum energy code insulation and depth requirements. Q ACCESS E FLOOR HATCH 2-6 2-6 HINGED ALUMINUM DOORS BA-PPA PER IRC 314 IN EACH BEDROOM AND OUTSIDE OF THE SLEEPING AREA. ALL -� DETECTORS TO BE INTERCONNECTED AND POWERED BY 120VAC. Envelope Assemblies 3. STORM WATER SHALL BE CONTAINED AND RECHARGED THROUGH DRYWELL0 MARCH 17, 2023 AS INDICATED ON PLANS. ` ` 4. ALL WORK SHALL CONFORM TO NYS ENERGY CODE Ceiling:Cathedral Ceiling 380 21.0 28.0 0.020 0.026 8 10 Wall:Wood Frame,16"o.c. 1,164 24.0 0.0 0.054 0.060 49 54 5. CONTRACTOR TO COORDINATE ALL BUILDING DEPARTMENT INSPECTIONS AS Door;Glass Door(over 50%glazing)SHGC:0.19 96 0.290 0.320 28 31 Z Vinyl Frame 0 WINDOW SCHEDULE REQUIRED INCLUDING BUT NOT LIMITED TO: Window:Un 5.1. FOUNDATION, FOOTINGS AND WALLS FOR POURED CONCRETE (TWO SHGC:0.19 167 0.290 0.320 48 53Lu SYM NAME HEIGHT WIDTH NOTES Floor:Wall:All-WoodJoistnress 380 0.0 0.047 0.047 18 18 INSPECTIONS) Crawl Wall:Solid Concrete or Masonry MARVIN ELEVATE SERIES WOOD-ULTREX 5.2. ROUGH FRAMING WalDepth belowheight: :2grade:5' 2.0' 97 0.0 15.0 0.090 0.065 9 6 W01 BATH RO 1-7 5/8 RO 5-5 ELAWN 3319 2W, LOW E3,COLOR BARE WOOD Insulation depth:2.0' x"EBONY",SATIN NICKEL HARDWARE 5.3. INSULATION Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other MARVIN ELEVATE SERIES ALL-ULTREX ELAWN 5.4. FINAL calculations submitted with the permit application.The proposed building has been designed to meet the 20181ECC requirements in W 5 REScheck Version:REScheck-Web and to comply with the mandato requirements listed in the REScheck Inspection Checklist. 1 W02 KITCHEN RO 6-11 RO 3-3 - 4119+ELCAP 4163 MULLED, LOW E3,COLOR mandatory a AUGUST 16, 2016 8 WHITE x"EBONY",SATIN NICKEL HARDWARE 5.5. ELECTRICAL ROUGH ° MARVIN ELEVATE SERIES ALL-ULTREX ELAWN 5.6. ELECTRICAL FINAL Name-Title Ignaure Date W W03 KITCHEN RO 6-11 RO 2-1 2519+ELCAP 2563 MULLED, LOW E3,COLOR WHITE x"EBONY", SATIN NICKEL HARDWARE 1/411 = 11-011 MARVIN ELEVATE SERIES ALL-ULTREX ELAWN W04 KITCHEN RO 1-7 a RO 3-1 3719, LOW E3,COLOR WHITE x"EBONY",SATIN NICKEL HARDWARE FLOOR PLAN MARVIN ELEVATE SERIES ALL-ULTREX ELCAP W05 MEZZANINE RO 6-1 RO 6-1 7373, LOW E3, COLOR WHITE x"EBONY", FIXED Project Title:1650 Meday Report date:03/10/23 Data filename: Page 1 of9 A- 1 0 3 X 8 JOISTS 24" OC TYPICAL MEZZANINE 1. ALL WORK TO COMPLY WITH ALL CODES OF NEW YORK STATE RESIDENTIAL CODE 2020&TOWN CODES SECTION R325 2. MEZZANINE AREA EQUAL TO 177 SF OPEN TO ABOVE 3. AGGREGATE AREA OF KITCHEN/DINING/LIVING ROOM IS EQUAL TO 749 SF-MAXIMUM ALLOWABLE MEZZANINE EQUAL TO ONE-THIRD OF THE FLOOR AREA OF THE ROOM OR SPACE IN WHICH THE MEZZANINE IS LOCATED. THIS AREA IS EQUAL TO TO 246 SF AS PER R325.3 4. GUARDRAIL ENCLOSURE AROUND MEZZANINE TO BE 36"IN HEIGHT AS PER R325.5 OPEN TO ABOVE 5. EGRESS SHALL BE IN COMPLIANCE WITH SECTION R311.7 6. SHIP'S LADDER SHALL BE USED FOR EGRESS AS PER R311.7.12 7. ALL GLAZING ADJACENT TO EGRESS STAIR TO BE FULLY TEMPERED I TCHEN REFLECTED CEILING PLAN 2 SCALE: 1/4"= 1'-0" -- —`_ 20'-011 3'-8%,1 co 6 WO6 MEZZANINE �r- • OPEN TO BELOW M r CO r 36"HIGH GUARD RAIL 36"HIGH GUARD RAIL OPEN TO BELOW Woe LADDER TO \oo MEZZ rn F� 0FLOOR PLAN MEZZANINE 3 SCALE: 1/4"= 1'-0" U N 0- 0 N M O N O U = O i ROOFING SPECIFICATIONS -�-. O Z L 1. ENTIRE ROOF TO RECEIVE POLYISOCYANU RATE ROOFING BOARD MECHANICALYIn O ATTACHED, INSULATION BOARD SHALL BE FIRESTONE ISO95+ GL. FASTENERS SHALLcu �- BE COMPATIBLE FIRESTONE ALL PURPOSE FASTENERS AND PLATES. FASTENERS TO BE OF ADEQUATE LENGTH TO PENETRATE ALL EXISTING ROOFING MEMBRANES INTO I I — ` — — — _ _—_ ` co Z SOUND ROOF STRUCTURE. I —1 I U N 2. ROOF MEMBRANES SHALL CONSIST OF ONE PLY OF STICHBOND POLYESTER FABRIC I I I SET INMETACRI'LICSBASE COAT AND MULTIPLE WHITE TOP COATS. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - r - - - =5 - - - - - - - - - - - - - - - - - - - - - -I—I I I 3. PROVIDE FULL PERIMETER WOOD NAILER FOR ATTACHMENT OF GRAVEL STOPS AND I r- — — — — — — — — — — — — — — — — — — — — — GUTTERS I i I I 4. PROVIDE COMPATIBLE LIQUID APPLIED FLASHING AT ALL PENETRATIONS 5. CUT NEW REGLE:T AS REQUIRED AND INSTALL NEW STAINLESS STEEL COUNTER I I I II FLASHING INTO MASONRY CHIMNEY I I I 6. PITCH GUTTERS 1" IN 10' MINIMUM7� f I EXISTING FLAT ROOF PITCHED 1/4" PER 1'-0" I I ENTIRE ROOF TO RECEIVE 2" OF ADDITIONAL I I of e- l i INSULATION LION I I I I I I II EXISTING BUILDING �F-- - _- - - _- — — __ 7 II I Li II I I I i t II II II I I I I �— - - - - -i �- -�- - L - - - - - - - - - - - - - - - - - - - - s- - � = v I II II N � II II I I I II U) II II L1- o I I I I I I I 4" ROUND LEADER TIED INTO DRAINAGE PIPE L L1) M > II I II II I j � z U) I �- - I- - �- - - J I- - - -� I - - - - -� - - - - - - - - - - - - - � - - - - . - - - - - - - - - - �- - - - - - - - - - - - - �-- C - - - -I W � F— = �— Q PITCH GUTTER TO LEADERLo I L — F— tj r — � II II � 1I II IL 5" GUTTER Li 5" GUT[ER 4" ROUND LEADER TIED INTO DRAINAGE PIPE i 4" ROUND LEADER TIED INTO DRAINAGE PIPE II II II II O MAIN ROOF PLAN II II SCALE: 1/4" = 1'-0" II II L- - - - - - - - - -i 1 NEW FLAT ROOF PITCHED 1/4" PER 1'-0" MIN ENTIRE ROOF TO RECEIVE 7.5" OF POLYISO INSULATION O U ''^^ J_ METACRYLICS ELASTOMERIC ROOF SYSTEM U vJ Q � C't) � 2 X 6 FRAMED PARAPET 0 �` I.L Lo V 4"x 3"OVERFLOW SCUPPER MTD 2"ABOVE ROOF W CV U) 'DENSGLASS Z Q 3 LAYERS 2-1/2"POLY ISO ROOF INSULAT N Zp'. 0 16OZ COPPER FLASHING PITCH 1/4"PER 12"MIN Q E STAGGER ALL JOINTS /� W 4"x 4"COPPER CORNER SCUPPER 4n X 3�� OVERFLOW SCUPPER SET 211ABOVE LOW POINT OF O d- w 6"x 6"x 5"LEADER HEAD ROOF Z O 4"ROUND COPPER LEADER Q "ADVANTECH SHEATHING 4" ROUND LEADER 3 X 8-ROOF JOISTS 24"OC 4"X 4" SCUPPER AND LEADER HEAD 0 MARCH 17, 2023 n 1 X 6 T&G PINE Z DRYWALL o Lu ;A� UPPER ROOF PLAN �' ''� `" '� �' ' ui 1 � AUGUST 16, 2016 SCUPPER SECTION - t- CC SCALE: V=V-0" SCALE: 1/4' - 1'-0' x � 1/411 1 ROOF PLAN A- 103 . 00 U o— O N M O -1-- N O L /J E (u U 0.. O U) cu 0- a) ti z U cV GENERAL NOTES 1 . ALL WORK TO COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES 2. CONTRACTOR IS RESPONSIBLE FOR VERIFICATIONS OF ALL DIMENSIONS AND AA CONDITIONS BEFORE WORK BEGINS. A-105.00 3. ALL FOOTINGS TO REST ON UNDISTURBED SOIL � N MINIMUM 3'-0" BELOW FINISHED GRADE 11'-10%" 11'-10%" 11'-10%" COORDINATE 0'-0" CORNER OF EXISTING FOUNDATION 4. CONCRETE DESIGN AND CONSTRUCTION SHALL BE AS PER ACI 318-89 _ _ _ _ 19'-8 8 5. ALL CONCRETE TO BY 3500 PSI NORMAL WEIGHT — — t. 6. WELDED WIRE FABRIC SHALL CONFORM TO ASTM i — ----- — — ------- _ • S2 A-185. MIN. TENSILE STRENGTH OF 70,000 PSI ``' 14 DIA CONCRETE FOOTINGS TYP. _ � 7. ALL BAR REINFORCEMENT SHALL CONFORM TO �T � -� - ____ -- - - �- -- - _ _ � o0 2 X 2 CONC FOOTING _ BB I Z ASTM A-615 GRADE 60 -�;� I A-105.00 U) >- 8. FOUNDATION AND RETAINING WALL DESIGN AS �. 81 Q U PER 2015 I.R.C. 4 4 �2 i 5i8" x 12" ANCHOR BOLTS u 0 5 .C. R 0 I 4'-0" OC MAX TYPICAL CC — w I rn G F~- 6'-1y2" 6'_1y2" 73 LmEE B A 105.00 - TYP �h SIMPSON SDHD HOLD DOWNS TYP SEE SHT A-104.30 FOR LOCATIONS A-105.00 • ' SYM I DEMOLISH EXISTING 8" CMU c SLEEVE AROUND EXIST. I WASTE LINE FOUNDATION WALL f ( GG o EXISTING WASTE LINE i a s A � 3'-6" 7'-44" DD A-105.00 � A-105 I _ _. . ... . „_ _. . ..,. ... ... . . TYP I 7'-348" 6'-8'/8" 3 18" DIA CONCRETE FOOTINGS TYP. p I U Co kl- cc I Qcoc� A-105.00 I 0 L? /^ vJ SYM Z Q - 0 (oW 000, U d- - Qua I � � z MAINTAIN 2" CLEARANCE FROM SETBACK LINE Q 0000, i 0 0 0 0 0 0 0 0 01-6 Y4„ ® MARCH 17, 2023 Z 0 20'-4y2" 3" PVC SLEEVE TYPICAL ` ARS.: � � t a AUGUST 16 F Olt u A I , 2016 u"k ' Fm"k AT 1 'p" ""h L a ILQ . _ ` a � 0 AS NOTED SCALE. 1/4�� — 1 -0�� l�3rj, 17742 ���'� � FOUNDATION PLAN A- 1 04 . 00 U 0- 0 � � o :+- (1) o .E :'= o U � � L Q a) Z E v 0.. O U �- Ncu N Z U (V AA 2 X 2X12 PT GIRDER A-105.00 11'-104" 1'-104" — 11'-10�" COORDINATE 0'-0" CORNER OF EXISTING FOUNDATION 0 0 4'_4% 19'-8 8" N 2'-sy8" • L a, 3'-10" o pit c; cn 14" DIA CONCRETE FO TINGS TYP. C cn 0 2' X 2' CONC FOOTING o0 0'-0" _ _ _ _ _ _ _ _ _ _ _ _ .- H 2 x 1-3/4 x 5-1/2 LVL 2.0E C7 00 m I A-105.00 # \o \ X Eo m`' `" I 12 o 2" X 12" ANCHOR BOLTS c„ �d �� 6'-0" OC MAX TYPICAL W W ol r w o Z Q ►�: 6'-1y2" 6'-15/8 }- , �2' GG I 6-1 EE A-105.00 Q A-105.00 W TYP G • Ln Q 3'-112" r- GENERAL NOTES_ I • DEMOLISH EXISTING 8" CMU N N FOUNDATION WALL 00 � o 1 . ALL WORK. TO COMPLY WITH ALL CODES OF NEW o 0 zo YORK STATE & TOWN CODES, 2018 IRC I cn 9'-11" o cn 2. CONTRACTOR IS RESPONSIBLE FOR cn 0 02 VERIFICATIONS OF ALL DIMENSIONS AND 0 CONDITIONS BEFORE WORK BEGINS. 3 X 2X8 PT GIRDER 3. ALL EXTERIOR FRAMING MEMBERS TO BE ACA ' TREATED FOR GROUND CONTACT SYP #2 OR BTR. 4. ALL BUILT-.UP EXTERIOR HORIZONTAL MEMBERS 3-6" 2,-61 T-4Y4" 3'-4/4" ED WITH VYCOR FLASHING TAPE I I /2 TO BE COVERI I DD 9A YY TO 5. STUD SIZE, HEIGHT AND SPACING AS PER 2018 IRC, A-105.00 1 TYP R602.3.1 A-105.00 6. ALL INTERIOR SOLID WOOD FRAMING MEMBERS I 18" DIA CONCRETE FOOTINGS TYP. TO BE SPF #2 OR BTR 7. ALL SUBFLORING TO BE 4" T&G ADVANTECH 3'-0" 7'-3j" 6'-s%'� A-105.00 3'-oj" SHEATHING. GLUED AND NAILED WITH 8D RING SHANK NAILS. 6" ON PERIMETER AND 8" IN THE 38'-1j" FIELD. 10'-2j" cn co 2 u Q K KA M 1 'k 0� v rmh L A"m' < co 0 FlRbT FL Fr"4 N 8. ALL EXTERIOR SHEATHING TO BE 2 NOMINAL APA =� o w o L? @ RATED SHEATHING. ALL JOINTS TO FALL ON SCALE: 1 /4" = 1 �-011 \ MAINTAIN 2 CLEARANCE FROM SETBACK LINE z Q Q MEMBERS OR SUITABLY BLOCKED 0 z ~' ° 44'-0�" Q Q co w 9. ALL SHEATHING TO BE NAILED WITH 8d (0.131" dia) - - - - 9'-84" Q t co 0- RING SHANK NAILS 4" OC ON ALL EDGES AND 8" OC `- o IN THE FIELD. Q 10. ALL FASTENERS NAILED INTO TREATED MEMBERSCD TO BE CORROSION RESISTANT MARCH 17, 2023 11 . FOUNDATION AND RETAINING WALL DESIGN AS EXISTING RETAINING WALL 3" PVC SLEEVE TYPICAL PER 2018 IRC SECTION R404 Z 12. MAXIMUM STUD HEIGHT ALLOWED OF 18 FEET AS W PER R602.3.1 r Lu AUGUST 16, 2016 1/411W c U rf C 1ST FLR FRAMING PLAN A- 104 . 10 U METACRYLICS ELASTOMERIC ROOF SYSTEM _ O 2 X 10 RIM TYPICAL U CO 2 X 6 FRAMED PARAPET N o = O U � � 2" SHEATHING ON INTERIOR OF PARAPET 2 X 6 STUD WALL 16"OC TYP Q (/� >,. Z 1" DENSGLASS v 2 E ca .L- 3 LAYERS 2-1/2" POLY ISO ROOF INSULATION I I— — — ---_— --- __— U) }' STAGGER ALL JOINTS I I — - m 160Z COPPER FLASHING I I cu u N COR-A-VENT SV-3 I I A l .20 I I 3-1/2"x 12"24F-V4 DF GLULAM C I I I 2 x 8 RIM BOARD I I X ico 1/2 PLYWOOD SHEATING COR-A-VENT STURDI-BATTEN - _ 12" OC TYP. II � $" X 5" VG CEDAR SIDING 3 X 8 - ROOF JOISTS 16" OC 3-1/2 X 12 GLULAM 1 x 6 T&G PINE 3" ADVANTECH SHEATHING 17D 5-1/2" R-23 ROCKWOOL INSULATION 4 I _ I I OVERFLOW SCUPPER m I m — —. — LI PROSOCO MVP WRB CONTINUOUS - LAP OVER PARAPET 2 DRYWALL --------------------- -� FLASH ALL JOINTS WITH PROSOCO FAST FLASH SCUPPER AND LEADER W � ROOF FRAMING PLAN Q z PARAPET/WALL SECTION SCALE: 1/4"= 1'-0" SCALE: 1"= 1'-0" Q U cW I— G F AA A-105.00 PROPOSED ROOF LINE 3 11'-938" 11'-938" 11'-758" 5 A-106.20 4 A-106.10 EXISTING ROOF LINE A 106.10 2 X 6 STUD WALL 16"OC TYP --- 19'-8 8 N _.. ..... ... ...... GENERAL NOTES 3x 1-3/4 x 11-1/4 2.0 E LVL _ _ .< _ d 3 x 8 JOISTS 24"OC = - - --- - - -- - °- `r co 1 . ALL WORK TO COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES I 2x 1-3/4"x 11-1/4"2.0E LVL 2. CONTRACTOR IS RESPONSIBLE FOR _ �! VERIFICATIONS OF ALL DIMENSIONS AND I OPEN TO BELOW 00 4 3 X 1-3/4"X 11-1/4"2.0E LVL co ... CONDITIONS BEFORE WORK BEGINS. EXISTING STRUCTURE TYP M '` A-106.20 3. ALL ROOF JOISTS TO BE CONTINUOUS WITH 2 X 8 2 LO 00 o SOLID BLOCKING AT M I DSPAN A-106.20 _ =1 2 X 8 JOISTS 16"OC DOUBLE 2 X6 STUDS AT FULL HEIGHT WALL 4. SUBFLOOR AND ROOF SHEATHING TO BE 3" j � co � 4 ADVANTECH SHEATHING GLUED AND NAILED WITH I r Q CO @ W N U) RING SHANK 8D NAILSAWELDED WIRE FABRIC SHALL CONFORM TO ASTM S2 A-185. MIN. TENSILE ATTACH JOISTS WITH \ 2TRIPLEX8S 2X8 6"OCTUDS Z N X JOIST HANGERS 2 X 8 STUDS 16"OC TYP 0 STRENGTH OF 70,000 PSI � 5. ALL BAR REINFORCEMENT SHALL CONFORM TO C- � Z g 0 ASTM A-615, GRADE 60 cn � `� Q 6. MAXIMUM STUD HEIGHT ALLOWED OF 18 FEET AS 1 O PER R602.3.1 A-106.20 MARCH 17, 2023 FLOOR FRAMING PLAN Z @!EZZANINE SCALE: 1/4Omni " = 1'-0" PROPOSED ROOF LINE .o(j ti q ' "t�`��s`'� c�y�}, o AUGUST 16, 2016 1/411 a n� ui MEZZ & ROOF FRAMING 77742 �0PLAN A- 104 . 2 0 U � o � � o a� o o L vJ 2'-1" 1'-4Y4" Q aj Z s V 3'-0" E — 5'-9" 3'-4" c� U d. O cu Nca N M G OUTLINE OF EXISTING STRUCTURE T- -1 `- BOTTOM OF GIRDER I LUS 2" ABOVE EXISTING ROOJOISTS io — _ Lo _ � o - (T) ti 00 o - , O N O II I ) 16 W � - - - - - - - - 16'-5y4" Q U BUILDING SECTION WEST W 5 SCALE: 1/4" = 1'-0" LULD' NG SECTION EAST `o � 4 SCALE: 1/4" r BLOCKING FOR 7-1/4"X -3/4"LVL 2.0E HEADER SHEATHING EDGES TYP DOUBLE zxs HEADER TYP ALL WINDows DOUBLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ' " ' " " " " ' "PLYWOOD SHEATHING CONTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D NAILS 4"OC AT EDGES,8'IN SIMPSON A21 BOTH SIDES OF COLUMN TYP . . . . 2 X 6 STUDS 16"OC TYP "PLYWOOD SHEATHING " ' " ' 8D NAILS 4"OC EDGES " " 12"OC FIELD TYP . . . . . . . , , , . , BLOCF;ING AT SHEATHING TYP O . . . . J Q TOP PLATE FASTENED TO HEADER WITH 16D SINKERS 3"OCM U' CONTINUOUS BLOCKING AT SHEATHING EDGES TYP Q '^ @ �l! tel"/ OO 00 -- . . . HEIGHT OF STUDS TO 1 W MAXIMUM HE BE 8 T— r �'PL°WOOD SHEATHING 8D NAILS DOUBLE 2 X 6 HEADER TYP CV 8D COMMON NAILS 3' OC GRID AS PER IRC R602.3.1 AT FULL HEIGHT WALL TYP 4"OC AT EDGES 8"OC IN FIELD TYP 2 X 1-3/4"X 14" �.'.� AT HEADER . . . . . . . . . . . . . . . . . . . . . . . . Z I` o 2.0E LVL HEADER ~ Q SIMPSON CS 14 DOUBLE STRAP PORTAL FRAME SHEATHING FASTENED W 60"INSTALLED ON BACKSIDE OF WITH 8 D COMMON NAILS 3"OC ALL STUDS . . . . JACK STUD BOTH SIDES BLOCK OUT PLATES AND BLOCKING PROVIDE DOUBLE STUDS AT O Z . , . HOLD DOWNS TYP AT HEADER AS REQUIRED DOUB_E STUDS AT ALL HOEDOWNS TYP DOUBLE STUDS . . . . . FnI AT HOEDOWNS TYP SIMPSON STHD14 STRAP TIE HOLDOWN TYP DOUBLE BOTTOM PLATES SIMPSON STHD HOLDOWN TYP SIMPSON STHD HOLD DOWN TYP ANCHORED TO FOUNDATION 8"ANCHOR BOLT 8"EMBEDMENT o W/2"SQUARE WASHER TYP w uj TRIPLE 2 X 6 JACK STUDS ST FRAMING ELEVATION OEA „= „ NORTH ELEVATION �� L L � AUGUST 16, 2016 SCALE: 1/4 - 1 -0 � J��. ✓� . o Lij JUL SCALE: 1/4”= 1'-0" ��� �n w SCUTH FRAMING ELEVATION i,,zjr42 � WALL FRAMING DETAILS s P A- 1 04 . 30 U CL o U O CD 4 EXTEND EXISTING ROOF OVERHANG 0 2 X 1-3/4 X 11-1/4 LVL BEAM 4 X 4 PT POST 2 x 1-3/4 x 5-1/2 LVL SET ON 2 X L PT BLOCK < a) z GROUT CMU CORES SOLID AS REQUIRED 0 2 x 6 PT SILL TYP 1-1/2"CHAMFER TYP. L- T.O.WALL Q 3"SCH 40 PIPE COLUMN 2"CONC. RAT SLAB — [31'-6"] U) -�e >- ON 6-MIL VBMIRADRAIN DRAINAGE FABRIC 1-1/2"PVC WEEPS ca EXISTING CMU FOUNDATION WALL 6'-0"OC TYP m N z QQR 2 X 6 PT JOISTS 16"OC , . �•� : -, - . -.,_,, . 4'-4y4' 0 . i ,. �,�._ .,: EXISTING FOUNDATION -0" 2x2x12 PT BEAM BB FOUNDATION SECTION LedgerLOK 3-5/8"BOLTS 34"OC — FOUNDATION SECTION SCALE: 1/4" = 1'-0" 14"DIA PORCH FOOTING 3'-10" 4.4 1" AA PORCH FOOTING SECTION 01-1011 SCALE: 1/4"= 1'-0" 1-1/2"CHAMFER TYPICAL DECK #4 VERTICAL REBAR 24"O.C. #4 HORIZONTAL REBAR 12"FROM TOP OF WALL NEW FOOTING EXISTING FOOTING AND MID WALL 3-2x8 DECK BEAM 2 X#4 HORIZONTAL REBARS TYP W T.O.FOOTING 2"CONC. RAT SLAB 2 X 18"#5 REBAR DOWELS z -MIL VB ON 6 [27'-3 1/2"1 T.O.W. EPDXIED INTO EXITING FOOTING Q SIMPSON ABU66Z TYP. [28,-0"] — — 6" EMBEDMENT D W I- 18"DIA DECK FOOTING b.) — — 5 DECK FOOTING SECTION Lo Q DD SCALE: 1/4"= 1'-0" OUNDATION SECTION cc FOOTIN��ECTION RETAINING WALL AT DECK @Is CALE: 1/4"= 1'-0" r r SCALE: 1/4" 0 �v SCALE: 1/2"= 1'-0" G T.O.W. _EXIST GRA_DE_ __ T.O.W. [29'-10"] 1-1 "PVC WEEPST.O.DECK T.O.SF OCTYP = T_.O.GRADE BOF [24'-6"] (D FOUNDATION ELEVATION SCALE: 1/4"= 1'-0" O 1-1/2" CHAMFER TYPICAL U (.0 Q 3" PVC X 12" LONG SLEEVE FOR FENCE POST ' ' Q M O W 0 N U #4 VERTICAL REBAR 48" O.C. #4 VERTICAL REBAR 48" O.C. z Q �~„ p #4 VERTICAL REBAR 24" O.C. O ^ < C 0 � � � Lu D #4 HORIZONTAL REBAR 12" FROM TOP OF WALL 2 X #4 HORIZONTAL REBAR TYP 2 X #4 HORIZONTAL REBAR TYP z m AND MID WALL Ocf) Cn D C1) Q 2 X #4 HORIZONTAL REBARS TYP > 2 X #4 HORIZONTAL REBARS TYP 2 X #4 HORIZONTAL REBARS TYP W m Q ® MARCH 17, 2023 G) > 1 --' — Z i 0 O p — W 11-711 e 21-011 �, 21-011 --7, 01-711 =- i-01e �y�— RC,S,��;,� o AUGUST 16, 2016 3 2 X #4 BARS LAPPED AS SHOWN 8 FOUNDATION WALL TYP FOUNDATION WALL STEP TYP OLSCA4L ETAINING WALL TYP 1/2"= 1'-0" SCALE: 1/2"= 1'-0" SCALE: 1/2"= 1'-0" FOUNDATION DETAILS 77742 �. A� -1 A- 1 05 . 00 U MO N M O O O 0 U � r- L Q N Z =' U v EL O c ca O n N Z U N 2" ISO ROOF BOARD MECHANICALLY ATTACHED 2" ISO ROOF BOARD MECHANICALLY ATTACHED FLUID APPLIED ACRYLIC ROOFING FLUID APPLIED ARYLIC ROOFING 2" ISO ROOF BOARD MECHANICALLY ATTACHED 3/4" PLYWOOD ROOF SHEATHING > 3/4" PLYWOOD ROOF SHEATHING FLUID APPLIED ACRYLIC ROOFING Z Q 3X8 CEILING JOISTS 24" OC 3/4" PLYWOOD ROOF SHEATHING >— �z 3/4" HARDI FASCIA 3/4" HARDI FASCIA Q () 3/4" HARDI FASCIA 0 D W I- 1/4" HARDI SOFFIT 1/4" HARDI SOFFIT 1/4" HARDI SOFFIT �— 7/16" HARDI PANEL 7/16" HARDI PANEL 7/16" HARDI PANEL L Q 1/2" PLYWOOD SHEATING 3" RIGID INSULATION 3X8 CEILING JOISTS 24" OC 1/2" PLYWOOD SHEATING 3X8 CEILING JOISTS 24" OC co _ r- 7/16" HARDI PANEL 1/2" DRYWALL 1/2" PLYWOOD SHEATING 7/16" HARDI PANEL 7/16" HARDI PANEL 3" RIGID INSULATION 3" RIGID INSULATION 3/4" HARDI TRIM BOARD _ 2" RIGID INSULATION 1/2" DRYWALL 3/4" HARDI TRIM BOARD 1/2" DRYWALL " 3-1/2BATT INSULATION 3/4" HARDI TRIM BOARD 2" RIGID INSULATION 2" RIGID INSULATION PROSOCO MVP WR BARRIER , 1/2" DRYWALL i� 3-1/2" BATT INSULATION 3-1/2" BATT INSULATION DYKES 413 CASING 1/2" DRYWALL ll 2 X 1-3/4" X 9-1/4" LVL 2.0E PROSOCO MVP WR BARRIER 1/2" DRYWALL , i� DYKES 413 CASING PROSOCO MVP WR BARRIER TYP `Y'� 2 X 1-3/4" X 9-1/4" LVL 2.0E 1' X 2" PVC TRIM - F 3/4" PLYWOOD SUBFLOOR 3/4" PLYWOOD SUBFLOOR I; 3/4" PLYWOOD SUBFLOOR COPPER LEDGER FLASHING 6" FIBERGLASS BATT INSLUATION 6" FIBERGLASS BATT INSLUATION 6" FIBERGLASS BATT INSLUATION 1 X 6 TREX DECKING 2X8 FLOOR JOISTS 16" OC 2X8 FLOOR JOISTS 16 OC METAL Z FLASHING 2X8 FLOOR JOISTS 16" OC W/CONCEALED FASTENERS 5/8" x 2 " PVC TRIM111" x 2 " PVC TRIM 2X8 PT LEDGER �,�, 1T : I \ 1/2" X 4" HD GALV LAG BOLTS 34" OC MAX 2X8 PT DECK JOISTS 16" OC 2 X 6 PT SILL PLATE 2 X 6 PT SILL PLATE 2 X 6 PT SILL PLATE COPPER TERMITE SHIELD COPPER TERMITE SHIELD COPPER TERMITE SHIELD 1/2" X 10" SILL ANCHOR BOLTS 6'-0" OC MAX " 1/2" X 10" SILL ANCHOR BOLTS 6'-0" OC MAX 1/2" X 10" SILL ANCHOR BOLTS 6'-0" OC MAX 2" RIGID INSULATION 2" RIGID INSULATION 2" RIGID INSULATION 6 MIL VAPOR BARRIER TOP EDGED CAULKED TO FOUNDATION WALL 6 MIL VAPOR BARRIER TOP EDGED CAULKED TO FOUNDATION WALL 6 MIL VAPOR BARRIER TOP EDGED CAULKED TO FOUND. WALL 2" CONCRETE RAT SLAB ON 6 MIL VAPOR BARRIER a 2" CONCRETE RAT SLAB ON 6 MIL VAPOR BARRIER a j 2" CONCRETE RAT SLAB ON 6 MIL VAPOR BARRIER O d d d M 2i co Wco Z Q IN Q EXTERIOR WALL SECTION AT DOOR EXTERIOR WALL SECTION AT WINDOW EXTERIOR WALL SECTION TYP z 1 _ ! 2 11 _ 11 3 11 _ 11 ° O � f SCALE: 3/4 — 1'-0" SCALE: 3/4 — 1 -0 SCALE: 3/4 — 1 -0 Q (D w ") '----' z O U) Q 0 MARCH 17, 2023 Z O W w L. a .. ij., o AUGUST 16, 2016 W Q 3/4" = 1'-0" 1( • EXTERIOR WALL SECTIONS A- 1 06 . 00 U o- o LIQUID APPLIED METACRYLIC ROOFING co p LIQUID APPLIED METACRYLIC ROOFING LIQUID APPLIED METACRYLIC ROOFINGN p v o 2" GYPSUM ROOF SHEATHING Q Z 2" GYPSUM ROOF SHEATHING2" GYPSUM ROOF SHEATHING E cu t' Y 3 X 2.5" ISO ROOF BOARD MECHANICALLY ATTACHED 3 X 2.5" ISO ROOF BOARD MECHANICALLY ATTACHED 3 X 2.5 ISO ROOF BOARD MECHANICALLY ATTACHED v 3/4" PLYWOOD ROOF SHEATHING 3/4" PLYWOOD ROOF SHEATHING 3/4" PLYWOOD ROOF SHEATHING c ca 0- N � � Z U N COPPER DRIP EDGE COPPER DRIP EDGE COPPER DRIP EDGE 1 X 6 VERTICAL CEDAR SIDING 1 X 6 VERTICAL CEDAR SIDING _ _ _ _ 1 X 6 VERTICAL CEDAR SIDING I COR-A-VENT STURDI-BATEN 16" OC j 1 X 5 NOMINAL V-GROVE PINE SIDING 1 X 5 NOMINAL V-GROVE PINE SIDING 1 X 5 NOMINAL V-GROVE PINE SIDING 3X10 CEILING JOISTS 16" OC COR-A-VENT STURDI-BATEN 16" OC 3X10 CEILING JOISTS 16" OC COR-A-VENT STURDI-BATEN 16" OC 3X10 CEILING JOISTS 16" OC 1/2" PLYWOOD SHEATING 3" RIGID INSULATION 3" RIGID INSULATION 3" RIGID INSULATION 5-1/2" BATT INSULATION 1/2" DRYWALL PROSOCO MVP WR BARRIER 5-1/2" BATT INSULATION 1/2" DRYWALL 5-1/2" BATT INSULATION ui > � ® z Q 1/2" DRYWALL �— QU Q D w f- 2 X 6 FRAMING 16" OC TYP 2 X 6 FRAMING 16" OC TYP ~ u Q Cfl 2 X 1-3/4" X 14" LVL 2.0E 2 X 1-3/4" X 5-1/2" LVL 2.0E 3X8 CEILING JOISTS 24" OC LVL HEADER AS PER STRUCTURAL DRAWINGS 1 PROSOCO MVP WR BARRIER TYP T 1/2" DRYWALL 1 � 5-1/2" BATT INSULATION PROSOCO MVP WR BARRIER O 1' X 2" PVC TRIM --� I 3/4" PLYWOOD SUBFLOOR 3/4" PLYWOOD SUBFLOOR 3/4" PLYWOOD SUBFLOOR co Q 6" FIBERGLASS BATT INSLUATION 6 FIBERGLASS BATT INSLUATION COPPER LEDGER FLASHING I 6" FIBERGLASS BATT INSLUATION < . . Q M 2 1 X 6 TREX DECKING I 2X8 FLOOR JOISTS 16" OC 2X8 FLOOR JOISTS 16" OC W Q Ll? @ W/CONCEALED FASTENERS 2X8 FLOOR JOISTS 16" OC z Q 04 Q 2X8 PT LEDGER Z ti Q O � 1/2" X 4" HD ^ GALV — w LAG BOLTS 34" OC MAXw 2X8 PT DECK JOISTS 16 OC - � COPPER TERMITE SHIELD � -' 2X6 PT SILL PLATE � �; 2X6 PT SILL PLATE O 2 X6 PT SILL PLATE -' COPPER TERMITE SHIELD ) COPPER TERMITE SHIELD Q 1/2" X 10" SILL ANCHOR BOLTS 4'-0" OC MAX a 1/2" X 10 SILL ANCHOR BOLTS 4'-0" OC MAX a 1/2" X 10" SILL ANCHOR BOLTS 4'-0" OC MAX -' d d 2" RIGID INSULATION d 2 RIGID INSULATION El 2" RIGID INSULATION 6 MIL VAPOR BARRIER TOP EDGED CAULKED TO FOUNDATION WALL LL 6 MIL VAPOR BARRIER TOP EDGED CAULKED TO FOUNDATION WALL { I 6 MIL VAPOR BARRIER TOP EDGED CAULKED TO FOUND. WALL ® MARCH 17, 2023 I 2" CONCRETE RAT SLAB ON 6 MIL VAPOR BARRIER . . 2" CONCRETE RAT SLAB ON 6 MIL VAPOR BARRIER 2" CONCRETE RAT SLAB ON 6 MIL VAPOR BARRIER a _� . ,�- 0 a 4 G 0�, o AUGUST 16, 2016 EXTERIOR WALL SECTION AT DOOR EXTERIOR WALL SECTION AT WINDOW MEZZANINE WALL SECTION TYP w 4 3/4" = 1'-0" SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0" W EXTERIOR WALL SECTIONS A- 1 06 . 10 U � O L) C ~o (D O .� o U v-- i Z �= U (u i V FL O N N � � Z U �y o COol00 ti —�j mmmmmmq r &—SCALORTH ELEVATION 77 E: 1/4" W � Z U) Q LJLJ QU W c �_ G I— Ln Q Cfl 2 r O C/) (D Q z Q ti a Zti � � � < o ❑ a- N I filill z 0 CV (n Q ® MARCH 17, 2023 EAST ELEVATION SOUTH TIO ELEVAN o LLJ 4 SCALE: 1/4" = 1'-0" SCALE: 1J4" FI7 aRCy':� o AUGUST 16, 2016 ui C) 1/4" = 1'-0" f�K ` ` rp '� ELEVATIONS ►� � . �Jr, r 1774 J A-200 . 00 U CL o � ( ~o 4- cu o U b i � z VTR c i �jY �- N c6 cu n- z VTR LOOP TRAP IN ISLAND 1-1/2 II i KS D1V k FIRST FLR. � 9 t -- -- - - - �i 211 - 2„ KITCHENSANITARY PIPING SCALE: N.T.S. I I - EXISTING TO SEPTIC I ; inn 61 I W VTR �R /Q z i 2" 2„ 3 SS WC �1-112 LAV _ 2„ WM _. ... cl 1-112"' 1 112 �2 W f- I „ 2„ 3„ 2 i SHR -211 - FIRST FLR. U-) Q C0 7> r 3” , i BATHROOM SANITARY PIPING 3 SCALE: N.T.S. 0 U c/) Q . . Q C`7 CD Lo W 1 U zQtiQ � zr- Q PLUMBING NOTES p CD W 1 . ALL PLUMBING MEANS AS PER 2018 IPC, IRC AND SOUTHOLD TOWN LOCAL CODES Q � a 2. ALL DWV PIPING TO BE SCH 40 PVC OR ABS -' 0 3. ALL CONNECTIONS BETWEEN PVC AND ABS AS PER APPROVED ADHESIVES 4. ALL WATER PIPING TO BY TYPE L COPPER OR PEX. ALL FITTINGS, VALVES AND SOLDER TO BE LEAD FREE 5. PROVIDE WATER HAMMER ARRESTORS AT ALL FAST CLOSING VALVE. ALL WATER HAMMER ARRESTORS TO BE ® MARCH 17, 2023 INSTALLED N SERVICEABLE LOCATIONS 6. ALL WATER PIPING TO RECEIVE FIBERGLASS INSULATION CR EQUAL AS PER NYSECC. PROVIDE CONTINUOUS Z 0 VAPOR BARRIER. 7. ALL FIXTURES AND TRIM TO BE SUPPLIED BY OWNER. •?,Erj �cyy�� o AUGUST 16, 2016 lk N A w J 1/4" = 1'-0" ui PLUMBING PLAN 1774 • ��," 3s�1' , P- 100 . 00 U o- o 0 (y) (D o .� o L 7 Z E c L UP TO 12 X 12 RA FILTER GRILLE !V^ MOUNTED IN WALL,OFFSET 2"IN WALL V) 'Y 3x10 CAVITY CU UP TO 4 X 12 FLOOR REGISTER 0- CU 7 Z 100 CFM ` ? 7-FLEX 92 CFM FLEX .. 148 CFM 8"FLEX i , i i I , CONDENSER - MITSUBISHI SUZ KA18NAHZ 16"RIGID TAKEOFF MIN AIR HANDLER-MITSUB13HI SVZ KP18NA RETURN 15x16 x60 " PLENNUM SUPPLY PLENUM 545 CFM 12 x 24 RA FILTER GRILLE 14"FLEX MOUNTED ABOVE DOOR 15"MIN 8"FLEX 42 CF 8"FLEX " 2 CFM '< .,- Ago 8"FLEX i 8 142 CFM 14 6x12 6x12 (00� calc Project Name:1650 Meday Expansion { i Address:1650 Meday Avenue,Mattituck,NY , OUTDOOR DESIGN CONDITIONS _ _._____•__ �_ Weather station:Suffolk Co.AP,East Quogue(Islip DD) Summer Outdoor F: � Summer Indoor F: Design Grains: o Daily Range: z j _... ... Winter Outdoor F: o Winter Indoor F: Cooling RH: .r . Elevation(Ft): : S 3 : f - LOAD TOTALS HVAC System:HP-1 CALCULATION TO Q U UJi S - r e: Heating BTUH: s ' Heated square footag g Cooled square footage: Cooling BTUH: Heated volume(above grade CF): n CFM: Cooled volume(above grade CF): Sensible cooling: w Exposed wall area(SF): Latent cooling: - SHR: _ r i Load Calculation I P111, pq f Coaling - i HeatingLMJ = 9 0 5,000 10,000 15,000 20,000 BTUH i : , Approved ACCA MJ8 Calculations Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. " All computed calculations are estimates on building use,weather data,and inputted values such a R-Values,window types,duct loss,etc.Equipment selections shouldy , meet both the latent and sensible gain as well as building heat loss. , MANUALD-1650MEDAYAVE Friction Rate Worksheet GENERAL NOTES: 1. ALL WORK TO COMPLY WITH 2018 IRC, NYS BUILDING CODE AND SOUTHOLD Step 1) Manufacturer's Blower Data 2 TOWN CODE O 2. ALL DUCTWORK INSTALLED IN UNCONDITIONED SPACES TO BE INSULTED External static pressure(ESP)= o s Iwc CFM = 675 U WITH R-8 INSULATION AND A CONTIGUOUS VAPOR BARRIER. Step 2) Device Pressure Losses Cfl Q 3. AIR HANDLER TO BE INSTALLED ON SUSPENSION SPRING HANGERS FROM (Y Direct expansion refrigerant coil ('7 C� STRUCTURE. Electric resistance heating coil r Q L? rJ 4. CONDENSER TO BE INSTALLED ON RAISED LEGS Hot water coil �"` �' 0 rn Heat exchanger .M F��'q� y,, z Q 5. PROVIDE BALANCING DAMPERS AT ALL SUPPLY TAKE-OFFS Low efficiency filter 014 �t � L. ��:. High or mid-efficiency filter �; �; '�` z Q Electronic filter . O O w Humidifier ; Supply outlet 0.031 Return grille 0037 �� �;� a• Q C a Balancing damper 0.03 Z Other device �� 77742 0,/ 0 Total device losses(DPL) o z3a '�'�! < Step 3) Available Static Pressure ASP= ESP-DPL=( 0.50 _0.238 )= 0.262 IWC A MARCH 17, 2023 Step 4) Total Effective Length(TEL) Supply-side TEL+ Return-side TEL=( 225.5 + 1465 )= 372 FEET o 0 Step 5) Friction Rate Design Value(FR) ASP x 100 TEL FR value from friction rate chart = 0.07 0.06 500 :Inadequate Fan Pertormance 0.08 o AUGUST 16, 2016 450. 400 i 1 0.10 W 350 0.12 a 1/411 — 1 0" 300 _ ,.._..._. . ._ , 0 — - 0.14 A/ / 250 0.18 150 W MECHANICAL PLAN 150 100 50 or •High runout velocity I,p` //�' `/' 1 00 - 00 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 Y Available Static Pressure U n- o 4 . o T C 4"6 V�JCTI� i r TT 'J I I r; ���' � F WP t SEE REFLECTED - .. - t W z CEILING PLAN cu EX ' U a. o / GFI WP UC U /} /— WP20 cu 112 Z : WINE U N FRIG UC LIVING ROOM I DINING ROOM (EXIST) SEE REFLECTED ` - = CEILING PLAN 1- I : Ii j t , J .. ,.. ,.. ...,.. _ TO MEZZANINE co EXG co _ _ _..,._... ... .... .. ... _. " WP CO cot EXG EXG EXG ! \ « BEDROOM BEDROOM BEDROOM (EXIST) (EXIST) (EXIST) n A KITCHEN REFLECTED CEILING PLAN 2 SCALE: 1/4"= 1'-0" GF' Wp WP 3 co a Qz W I- 36"HIGH PARTITION BATH p I— (EXIST) CD � � B F � 3 FLOOR PLAN 1 SCALE: 1/4"= 1'-0" FLOOR PLAN MEZZANINE 3 SCALE: 1/4" = 1'-0" O U LIGHTFIXTURE SCHEDULE2 co 2i ELECTRICAL NOTES SYM NAME VOLTAGE WATTAGE MAKE/MODEL w LO N u 1. ALL WORK TO CONFORM TO THE LATEST NATIONAL ELECTRICAL CODE, z Q ti ¢ SOUTHHOLD TOWN CODE AND ALL OTHER GOVERNING AGENCIES q BATH 120 LED SUPPLIED BY OWNER 3 Q --� < 2. ALL EXTERIOR AND UNDERGROUND WIRING SHALL BE RUN IN PVC CONDUIT O d' w 3. ALL INTERIOR WIRING SHALL BE NON-METALIC (NM) CABLE B KITCHEN / MEZZANINE 120 LED - 14 W KUZCO KUZP 135786 z 4. ALL LOW VOLTAGE WIRING SHALL EE MINIMUM 14 GA. DIRECT BURIAL Q CABLE 5. ALL CONDUCTORS SHALL BE THWN(THHN COPPER C LAUNDRY 120 LED - 15.5 W WAC R3ASDL 6. ALL EXTERIOR AND DEVICES SHALL BE INSTALLED IN WEATHR-PROOF ENCLOSURES A �, ® MARCH 17, 2023 7. ALL DEVICES SHALL BE DECORA STYLE, COLOR WHITE D EXTERIOR A 120 LED - 10.5 w X 2 WAC CALIBER TWO LIGHT !R*, � ��~ 8. PROVIDE ADDITIONAL. CIRCUIT BREAKERS IN EXISTING PANEL BOARD '�-�03 - L AS REQUIRED 9. PROVIDE GFIC PROTECTED OUTLETS IN ALL EXTERIOR APPLICATIONS E EXTERIOR B 120 LED - 18 W WAC TUBE 5" BLACK AND GARAGE AS REQUIRED ��, � 10. PROVIDE ARC FAULT PROTECTION IN AS REQUIRED BY CODE. 11. ALL SWITCHES TO BE LOCATED 48" AFF TYPICAL, ALL RECEPTACLES TO F EXTERIOR C 120 LED - 18 W WAC HR-LED418-R =' 17742 BE MOUNTED 18" AFF TYPICAL +D�r 12. NO FIXTURES OR DEVICES TO BE INSTALLED WITHIN 5' OF HOT TUB AUGUST 16, 2016 0 13. REFERENCE DETAILS AND ELEVATIONS FOR FIXTURE INSTALLATION G UTILITY 120 LED SUPPLIED BY OWNER LL LOCATIONS v „ - 14. COMBINATION SMOKE= AND CO DETECTORS TO BE INSTALLED IN ALL � 1/4 - 1 0 BEDROOMS AND OUTSIDE OF BEDROOMS AS SHOWN. ALL UNITS TO BE W 120V HARDWIRED AND INTERCONNECTED TOGETHER. ALL DEVICES TO ELECTRICAL PLAN BE WALL MOUNTED BETWEEN 4" AND 12" FROM CEILING E- 100 . 00