Loading...
HomeMy WebLinkAbout48064-Z ;�oguFFOt�leeGy Town of Southold 3/13/2023 P.O.Box 1179 o ` 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43921 Date: 3/13/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 6285 New Suffolk Ave., Mattituck SCTM#: 473889 Sec/Block/Lot: 115.-6-30 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/10/2022 pursuant to which Building Permit No. 48064 dated 7/14/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Felakos Jr,James&Sieczka,Elizabeth of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48064 11/22/2022 PLUMBERS CERTIFICATION DATED Au ri ed Yidnature TOWN OF SOUTHOLD ago aye BUILDING DEPARTMENT 0 TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48064 Date: 7/14/2022 Permission is hereby granted to: Felakos Jr, James 6285 New Suffolk Ave Mattituck, NY 11952 To: remove existing solar panel system and install new roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 6285 New Suffolk Ave., Mattituck SCTM # 473889 Sec/Block/Lot# 115.-6-30 Pursuant to application dated 6/10/2022 and approved by the Building Inspector. To expire on 1/13/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building nspector *pE SOUTyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin( -town.southold.ny.us Southold,NY 11971-0959 D�yCOUn�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: James Felakos Jr Address: 6285 New Suffolk Ave city:Mattituck st: NY zip: 11952 Building Permit#: 48064 Section: 115 Block: 6 Lot: 30 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: GreenLogic LLC License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures 11 Pump Other Equipment: 20.4kW Roof Mounted PV Solar Energy System w/ (48) SunPower SPR-m425 Modules, SunPower Monitor, AC Disconnect x2, Combiner Panel Notes: Solar Inspector Signature: � r Date: November 22, 2022 S.Devlin-Cert Electrical Compliance Form lqajiv so 0(0 s s— TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION FOUNDATION 1ST ROUGH PL13G. FOUNDATION 2ND INSULATIOWCAULKING FRAMING /STRAPPING FINAL FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) /�4ELECTRICAL (FINAL) CODE VIOLATION PRE C/O RENTAL REMARKS: Aj ,A-4. DATE StZ INSPECTOR tow OF SOUTyO� - f # TOWN OF SOUTHOLD BUILDING DEPT. °ycouHr+��`' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: o4f 4vp4� -6 A0 XvsC-CA, J-J S 4 V4 aCNI�X- .T /A b0rnAC1d-- 2 ,41) r �Jn� Ll pir- ol,�4 v DATE ?—INSPECTOR .. pf SOUTyO� * # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATIO _N/'CAAULKING [ ] FRAMING /STRAPPING FINAL Sc ' [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE 2✓ INSPECTOR :i. •LI: ::n::'• FIEI;D TNSRE -0 �,,.:-,,': CTI, N':RR RT D'PTE' GQ.1VY' T.xS . . r _,-;• ., :; . I r. FOUNDATION:(IST): � FOUNDATION' .2ND ::;;:,,.{•:ti,,.:.;..,; �n -.1',:+.'.!':x'1:1,• .Y'.u;,,.}.��::,:, :'., `�. ,-1-- /�� 1:.:., ..', .; i::• V�j i:: :6•:n;, :- ,AQYMIl Q r.: .,f Y .:k::? �'... ,i s PI;UIVI�'' :.,. t.,�f.- ter• .�' .r,a�z.. ll , . �:.y1:,:j-i�' t;?Y.,,�i::�:;a"33,,.,1.ryi;,:. 1:a;11....d;�ab6 `;Y,^f':r:.,a..1'..�e: ///^111 :�,: 1 Lr';;« :•ij!. '�I,.,+..":�:'/..,• iii" , .. hrt.T..,., nS: _ ,j' , V--- w r• 1. .J•` ad•' 1.•. V'.,, .. 'a r,! y.. 4'e� INSLTY�ATIQN R:N: (.``,'; - - :�< ':,:;:.:- .. � . . . . .�. .. - . -Z , - STATE EI�t�RGY C,0 k, ' :..,..::�:i: . ;:•.:..: . %:i 4; .,a".};.5,•,}jF.�r=-�`ii" .1;,:'':.J,.: :' ,. . . . :Cj.;:� ij f�'.=':: .' ii4 Sf'�q',"Yg,--!.l,ya;; .`...? . �. Y..',A..;, ;i��.:,ii';',t'i",?^^r' !'l:y-:r.;o-r�tii.:%: , .'r �6.:ti�`,:'L+ .G.,;.lul:,i�{:�.\,i;1 as°'.i�: ti.:.':' L;a'":,1..4'`I.:V,,„.: �I:•:yv is . W4''. ..41 i..t.�:. rc,},S:'r:t. ''if:�':'�":.1*S,l:,l .Y+�':'`Iv -, /' �.4 Y!,,,- : ,1.31'',!`4[':., .f�,l.;;•�'' .`��:,: i. •:('"�;<:y^�•'ti•4f• af-Ilb:+/•LX-(`.,"~r:\,ai.,"•:�'.;..: a(. /Q -� .1:,\.. C-I" lV.i cut::: t �'•.� Wil'�."�''. a` r 71:: 7.v...:; ,^ " :: T 1,'.+7;:j,'r1?'7,: 'r•':;..,,_ .,:!_.1y,i::"li.�:::::.i:::. . #,. .)_, .` ,•---, i.4:'.i,?.^i•'.::1`x"9;'i. y F '::k.:' 4iH L;'.:: . . i,%',�'%,, ':i , :' d .11 k. - i• �. • 'r - , , . . r'J•/.:'ii?--.r "'i::r:4'�Wi ,, . V 1k:-i'Y.i7w•y:':Std'.' �1".i„I.-;.y:.�.: y�fis.-.,",;i�''S,?lkay`�';!''1T t/C.>17i`p,,tr`,y �,}.,•. U•ii! , %�f:•i::.. ;ti.:::..:,':F:i• f?./s�+fSa''R,�1i.Nr:�si:;;:.•r'..,•: :l• 'i 'i,,t0T. ^k. ; -n S • S �\' " �V 'n ,i �� ' '!. .). . .hI . 1 . \ TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 ]iit)s://www.southoldtowniiy.gov Date Received APPLICATION FOR BUILDING PERMIT or Office Use only E C E PERMIT NO. Building Inspector: L) JUN I'D 2022 Applications and forms must befillecl out in their,entlrety.Incomplete - applications will not be accepted.'Where the Applicant is not the owner,an, BUILDING DEPT. .Owner's Authorization form�(Page 2)shaill be pomp'lleted., TOWN OF SOUTHOLD Date:5/4/2022 ,OWNER(S)OF PROPERTY: Name:James Flellak,os.. SCI TIVI#1000-115-6-30 Project Address:6285 New Suffolk Ave, Mattituck,,NY 11952 Phone#:917-834-7433 Email:felakoS@ gMail.com Mailing Address: ........... CONTACT PERSON: , Name:"BarbaraLogic LLC ......... Mailing 11 Ad I dress:97 North,..Sea,Road, Southamptqp, NY 11968 Phone#:631-771-5152 X1 17 Email:Barbara(@Greenlogic.com ----------- 'DESIGN,PROFESSIONAL INFORMATION: Name:James J. Stout Architect & Associates Mailing Address:2 Greg Lane, East Northport, ........ _NY 11731 Pho ne.!:03.1-858793188-1 Email:stouthu.bOiamessto,u,tarc.h....com., CONTRACTOR.INFORMATION: Name:GreenLogicLLC Mailing Address:97 North Sea,,Ro,a 11968 ------ �0,_$�QVthqjMlq Phone#:631-771-5152 Email:,AM@Greenlogic.com DESCRIPTION OF PROPOSED CONSTRUCTION E]NewStructure ElAddition ®Alteration EIRepair ElDemolition Estimated Cost of Project: Rother Solar Panels $ 69,000 Will the lot be re-graded? E]Yes ®No Will excess fill be removed from premises? E]Yes ®No PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes�Ao IF YES, PROVIDE A COPY. 0 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):GreenLogic LLC DAutho/riiz�ed Agent []Owner Signature of Applicant: Date: 5` /lot'A STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be'performed'in the manner set forth-in the application file therewith. Sworn before me this day of Ma ,20.23- Notary Public BARBARA A CASCIOTTA Notary Public-State of New York No.01-CA4894969 PROPERTY OWNER AUTHORIZATION qualified in Suffolk County Commission Expires May t1,2023 - - (Where the applicant is not the owner) I� Jim Felakos residing at 4-le GreenLogic LLC cJlCi' c f� ( o hereby authorize to apply on my behalf to th wn of Southold Building Department for approval as described herein. _ O r s Signature _ . Date Print wner's h.am 2 { M, C V I� Su¢fk BUILDING DEPARTMENT- Electrical In or �Ca C`i✓ TOWN OF SOUTHOLD JUN 1'.0 2022 - Town Hall Annex - 54375 Main Road - P Box '1X91-DING DEPT: is a Southold, New York 11971-0959 TOWN OF SOUTHOLD Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(Dsoutholdtownny.gov — seand(�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 5/4/2022 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Phone No: 631-771-5152 ®krequest an email copy of Certificate of Compliance Address.: 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: James Felakos Address: 6285 New Suffolk Ave, Mattituck, NY 11952 Cross Street: Phone No.: 917-834-7433 Bldg.Permit#: wo email: felakos@gmail.com Tax Map District: 1000 Section: 115 Block: 6 Lot: 30 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (56) SunPower SPR-X22-360-E-AC panels >:t (56) SunPower SPR-X22-360-E-AC micro inverters (1) SunPower PVS6 monitor System Size: 20.160kW Check All That Apply: Is job ready for inspection?: DYES ❑✓ NO ❑Rough In - ❑✓ Final Do you need a Temp Certificate?: ❑✓ YES [:]NO Issued On 5/4/2022 Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground [:]Overhead # Underground Laterals ❑1 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx REVISED BUILDING DEPARTMENT Electrical Inspector TOWN OF SOUTHOLD %\0 Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerlD-southoldtownny.gov — seand(a southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Phone No: 631-771-5152 Mkrequest an email copy of Certificate of Compliance Address.: 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: James Felakos Address: 6285 New Suffolk Ave, Mattituck, NY 11952 Cross Street: Phone No.: 917-834-743 Bldg.Permit#: email: felakos@gmail.com Tax Map District: 1000 Section: 115 Block: 6 Lot: 30 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (48) SunPower SPR-M425-H-AC panels «`t (48) Enphase IQ7HS micro inverters (1) SunPower PVS6 monitor System Size: 20.400Kw Check All That Apply: Is job ready for inspection?: DYES ❑✓ NO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: ❑✓ YES [—]NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame[—]Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION 17- 10 OCT 21 2022 Electrical Inspection Form 2020.xlsx B$J1rLDE\TG DEPT. TO'R'N OF SGUTIxOLID Suffolk County Executive's Office of Consumer Affairs i VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 DATE ISSUED: 12/10/2007 No. 43858-ME SUFFOLK COUNTY Master Electrician License � This is to certify that ROBERT 3 SKYPALA doing business as GREENLOGIC LLC having given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York. Additional Businesses k NOT VALID WITHOUT DEPARTMENTAL SEAL j ANDA'CURRENT CONSUMER AFFAIRS IR CARD � - a. Director 7 -_J DATE(MM/DD/YYYY) ,eco CERTIFICATE OF LIABILITY INSURANCE `�• 02/01/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Nicholas Zulkofske Brookhaven Agency,Inc. PHONE 631 941-4113 Fwn.AX 631 941-4405 100 Oakland Ave,Ste 1 E-MAIL Certificates@brookhavenagency.com Port Jefferson,NY 11777 INSURERS AFFORDING COVERAGE NAIC p INSURER A: Southwest Marine&General Insurance Co. INSURED INSURER B: Merchants Preferred Insurance Co. GreenLogic,LLC INSURER C: First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER D: National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E: AGCS Marine Insurance Co. INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTRYL(MM1DDNYYY1 X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A CLAIMS-MADE OCCUR DAMAGE TO RENTED 100,000 X Contractual Liability X X GL202200012922 01/31/2022 01/31/2023 MED EXP(Any oneperson) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY PRO- F—]LOC PRODUCTS-COMP/OP AGG $2,000,000 JECT OTHER: E&O Liability $1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1,000,000 BX ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED X X CAP1043565 08/11/2021 08/11/2022 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS PROPERTY DAMAGE X HIRED NON-OWNED $AUTOS ONLY X AUTOS ONLY $ UMBRELLA LAS OCCUR EACH OCCURRENCE EXCESS LIAB HCLAIMS-MADE AGGREGATE $ DED I I RETENTION $ WORKERS COMPENSATION PERTtITF FR OTH- AND EMPLOYERS'LIABILITY Y/N ANY OFFICER/MEM ER EXCLUDED?ECUTIVE❑ E.L.EACH ACCIDENT $ N/A see separate certificate (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ C NYS Disability D251202 04/1112021 04/11/2022 Statutory Limits E Installation Floater/Property SML93076366 04/15/2021 04/15/2022 $300,000 $2,500 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <> ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD YOK Comp Workers' CERTIFICATE OF 5TA7E Bompel�sa#i®n NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Legal Name&Address of insured(use street address only) 1b.Business Telephone Number of Insured Greenlogie LLC 631-771-5152 97 North Sea Rd.,Suite 3 1 c.NYS Unemployment Insurance Employer Registration Number of South Hampton,NY 11968 insured Work Location of Insured(Only required if coverage is specifical(y limited to 1 d.Federal Employer identification Number of Insured or Social Security certain locations in New York State,i.e.,a.Wrap-UP Policy) Number 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carder (Entity Being Listed as the Certificate Holder) United Wisconsin Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"1 a" Building Department 53095 Route 25 WC589-00169-021-SZ Southold,NY 11971 3c.Policy effective period 12/01/2021 to 12/01/2022 3d,The Proprietor,Partners or Executive Officers are Fj included.(only Check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law..(To use this.form,New York(NY)must be listed under Item3 on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiumsthat cancel the policy or eliminate the insured4rom the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate Is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information oniy and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities,beyond those.contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract Issued by a certificate holder,the business,must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the Insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Alicia Christiansen (13,t name of authorized representative or licensed agent of insurance carrier) 3 - Approved by: (Signature) ( ) Title: Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier:941-306r3077 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov voW Workers' CERTIFICATE OF INSURANCE COVERAGE STATECompetlSatian Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie la.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured GREENLOGIC,LLC 631-941-4113 97 NORTH SEA ROAD,SUITE 3 SOUTHAMPTON,NY 11968 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD BUILDING DEPARTMENT 3b.Policy Number of Entity Listed in Box 1 a" 53095 ROUTE 25 DBL251202 SOUTHOLD, NY 11971 3c.Policy effective period 04/11/2021 to 04/10/2023 4. Policy provides the following benefits: ❑D A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: Q A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as describedabbove..' Signed 4/7/2022 B (Woy �NUUrDate Slgn (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 4113,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 111111111D°°°1°°°°°1°1°!11°!'°'!°!°°1111111 6 X Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIAL 1EG14WAY W HAUPPAUGE,NEWYORK 11788 DATE ISSUED: 5/25/2006 No. 40227-H SUFFOLK COUNTY 3A Home Improvement Contractor License This is to certifv that MARC A CLEAN doing business as GREEN LOGIC LLC having ftumished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York is hereby licensed to conduct business as a HOME r IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Businesses NOT VALID WITHOUT DIEPARTMENTAL SEAL AND A CURRENT CONSUNJER AFTAIRS ID CARD Director GREENLOGICO ENERGY June 9,2022 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: James Felakos 6285 New Suffolk Ave Mattituck, NY 1000-115-6-30 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec.sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, '3wdkwiaa ,wcioftac Barbara Casciotta Account Manager Barbara@Greenlogic.com GREE QGt�J1..�15,2,&Erjgn�ogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S. Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 GREE LOGIC° ENERGY October 19, 2022 OCT 2 1 2022 BUrLDING Dr-,PT. The Town of Southold TOWN OF SOUTHOL D Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Project Info: Building Permit No. 48064 Jim Felakos 6285 New Suffolk Avenue Mattituck, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the solar electric system we installed at the above reference address. As the system has changed, I have also enclosed as built Glans, revised electrical application and electrical drawing. Please let me know if you have any questions about the installation. Sincerely, 53aw&ua ewc&v& Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC •www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd., #106 Southampton, NY 11968 Rosyln Heights, NY 11577 F----------------------------NEW EQUIPMENT ----- - _ __ EXISTING SERVICE -� 120/240, 1 PH, 3W ' (TYPICAL SYSTEM SCHEMATIC. FINAL INSTALLATION MAY VARY, REQUIRES LOCAL AHJ AND UTILITY APPROVAL) I 300A K W H � PV—SA-1 A AC—COMBINER PANEL = ® AC—CMB-1 _ _ _ _ N • • • 2 1 Ti 1 (PV ONLY) B ACA ADISCCONNECT AC DISCONNECT I C —, (EXTERIOR) (TAP SWITCH) TYP. PV ARRAY � I 1ooA � I MAIN �\ PV—SA—N A I A B N iFMI BKR-1 • • •N `� r L 1 I BKR-N J �--j MAIN MAIN TYPICAL PV MODULE WITH I I NON- I A B N A B N INTEGRAL DC/AC INVERTER II FUSED LL OSED I BKR-M IEGC I I N I GC PM-1 I I N N I I EGC I I � II p I I II I I I �,,, ECC j EGC II I I I I I I MAIN C/TI I AC DISTRIBUTION I AC DISTRIBUTION I II I I NEW ECC I (NON-CRITCAL LOADS)i (NON-CRITCAL LOADS L -------1---------------1— #— )I -- IRREVERSIBLE BOND, TYP. ' -� EXISTING1GEC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Felakos, James 6285 New Suffolk Ave R EEN LOGIC° Mattituck, NY 11952 ENERGY ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 1 of 4 Drawing No: FLKS-3LD1A Revision: 1 Revised: 9/26/2622 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 20.40 (PV) TOTAL PV KW RATING: (DC POWER) 18.432 (PV) QTY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL: SPR-M425-H-AC 48 PV MODULE: 425 W DC (NOMINAL), EACH SUNPOWER BRAND, MODEL: SPR-M425-H-AC 48 PV INVERTER: (INTEGRAL TO MODULE) 384 VA, 1.45 A, 240V AC, EACH REVISIONS Felakos, James 6285 New Suffolk Ave GREENLOGICO Mattituck, NY 11952 ENERGY ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 2 of 4 Drawing No: FLKS-3LD1A Revision: 1 Revised: 9/26/2022 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-5 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 10-MODULES PM-1 PRODUCTION MONITOR SUNPOWER PVS-6 AC-CMB-1 AC COMBINER PANEL, CRITICAL LOADS 250V, 200A, NEMA-1, 1-PH, 3-WIRE BKR-1...BKR-5 CIRCUIT BREAKER, PV-SA-1...PV-SA-5 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-M CIRCUIT BREAKER, PM-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 100A, NEMA-1, FUSED; FUSE RATING: 100A AC-DSC-2 AC DISCONNECT SWITCH (EXTERIOR) 25OV, 100A, NEMA-311, NON-FUSED REVISIONS Felakos, James � LOGICS 6285 New Suffolk Ave GREG Mattituck, NY 11952 ENERGY ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 3 of 4 Drawing No: FLKS-3LD1A Revision: 1 Revised: 9/26/2022 ELECTRICAL LOAD SUMMARY,AC CIRCUITS VOLTAGE MAX.AC TAG POWER, MAX RANGE CURRENT VOLTAGE, NOMINAL PV-SA-1 3072 WATTS 211-264 VAC 11.60 A AC 240 V,AC PV-SA-2 3840 WATTS 211-264 VAC 14.50 A AC 240 V,AC PV-SA-3 3840 WATTS 211-264 VAC 14.50 A AC 240 V,AC PV-SA-4 3840 WATTS 211-264 VAC 14.50 A AC 240 V,AC PV-SA-5 3840 WATTS 211-264 VAC 14.50 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 2" PVC-40 3/0 / 2 C THWN-2 2" EMT 3/0 / 2 D THWN-2 3/4" EMT 12 / 12 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM PROPOSED ELECTRICAL LOADS REVISIONS Felakos, ,lames GREG ELOGIC® 6285 New Suffolk Ave Mattituck, NY 11952 ������ ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 4 of 4 Drawing No: FLKS-3LD1A Revision: 1 Revised: 9/26/2022 No Vent Pipes Will Be Covered By The Solar Array ( .r # LOG IC �-� Fier=-RGY Legend: GreenLogic,LLC Approved Felakos,James AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge 6285 New Suffolk Avenue per R202 definitions per R324.6.1 as per R324.6.2.1 Mattituck,NY 11952 Total System Size:20.160kW 1 circuit of 11 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 4 on a 20A breaker Azimuth:177" Meter N 4 SunPower Monitoring System: svo 360W Panels SunPower Panel/Array Specifications: —� Panel:SPR-X22-360-E-AC —-I Racking:SunPowerInvisimount I Panel:61.39"X 41.18" Surface:73'3"X 86'8" Magic#:Invisimount I I 0 Legend: 1 I ! I 56 SunPower 360W Panels SunPower Invisimount Rail I I I I 1 0 93 Quick Mount E Lag I I IAPI IAP OB 2x8"Douglas Fir Rafter 24"O.C. I I I I I 2x6"Douglas Fir Truss 24"O.C. 0 1 1 O 0 1 svo Notes: ——————————1 1———————————�•' Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower I I Added Roof load of PV System:2.84psf I I I Engineer/Architect Seal: 35 SunPower 360W Panels svo 17 SunPower 360W,Panels 4 Drawn By:MA Drawing#12 of 13 a Date:4/29/2022 REV:A Drawing Scale:"=1.0' rl i CQUIPM ENT ... .......... ...... EXIST!!\,;(] SF`7�vi", PV--SA-1 AC-COMBINER PANEL 120/240, 1PH, 1 I AC,-C1v1B--1 (Py,/ LOADS ONLY) PV SA.-2 400A IKWH .; 1 PV-SA-3 A c BKR-1 AC-DSC-1 AC DISCONNECT BKR-2 PV-SA-4- 2 1 BKR-3 BKR-4 MAIN PV-SA-5 rM BKR-5 A B I FUSED r.SED PV-SA-6 BKR-6 f--an 5KR-7 IEGC N PV-SA-7 IF EGC EXISTING AC PANLEXISTING G GEC EC ff6 cu 20.160kW DC 17.640kW AC PROPOSED 3-LINE ELECTRICAL DIAGRAM . REVISIONS Felakos, Jim GREENLOGI ' 6285 New Suffolk Avenue EN E RC Y Mattituck, NY 11952 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Felakos-3LD1 Revision: 1 Revised: 3/24/22 ---- II- Lj_j ky) .. ........... ........... EQUIPtvitFNT .............. ........ ..................................................... EXISTING SIERVIfl FEB 15 20tj 3 LD 120/240, 1;''N, 3W BUILDING DEF f (TYPiCAL%)S-Ehi SCHEMA-11C. nNAL INSTALIAMN MAY VARY, TOWN MOUTH ILD REQUIRES LOCAL AH \, AND LMUTI APPROVAL) 400A ( KWH i PV—SA-1 ihAl AC—COMBINER PANEL C < AC—DSC-2 AC—DSC-1 lV NLY) P:11 AC DISCONNECT AC DISCONNECT XTERIOR) {TAP StNI*fCH' TYP. PV ARRAY 100A MAIN PV—SA —N A 9 BKR_1 FUT-, T 'MAIN MIAIN N! j 200A 200A BKR-N J0 TYPICAL PV MODULE NON- El [ri NI AI CJ i INTE RAL DC/AC: INVERTER FUSED BKR-.kl z I IE(;C I !EGC N I N N EGCI ccIL EGC MAIN Cirl 1 AC DIS'TRIBI-I'TRO(ti I AC DISTRIBUTI.'N I I NEW EGC I (NON—CRITCAL LOAUS) (KoN—CRITICAL LOADS: #6CU MIN. ............. IRREXIERSIBLE BOND, TYP. EXISTING GEC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Felakos, JamesJ. 6285 New Suffolk Ave GFREEPINLOGIC0 ENERGY Mattituck, NY 11952 2.) REVISED TO REFLECT ASBUILT CONFIGURATION ,fi ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION I We t4 Page 1 of 4 Drawing No: FLKS-3LD2A Revision: 2 Revised: 2/13/2023 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 20.40 (PV) TOTAL PV KW RATING: (DC POWER) 18.432 (PV) QTY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL: SPR-M425-H-AC 48 PV MODULE: 425 W DC(NOMINAL), EACH SUNPOWER BRAND, MODEL: SPR-M425-H-AC 48 PV INVERTER: (INTEGRAL TO MODULE) 384 VA, 1.60 A, 240V AC, EACH REVISIONS ` Felakos, James o.5�rs�•sr r� - ® 6285 New Suffolk Ave �¢` �' GENL®GIC Mattituck NY 11952 = ENERGY 2.) REVISED TO REFLECT ASBUILT CONFIGURATION �Qq QIt.633 OP} ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION rF bF n��a Page 2 of 4 Drawing No: FLKS-3LD2A Revision: 2 Revised: 2/13/2023 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-5 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-6 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PM-1 PRODUCTION MONITOR SUNPOWER PVS-6 AC-CMB-1 AC COMBINER PANEL, CRITICAL LOADS 250V, 100A, NEMA-1, 1-PH, 3-WIRE BKR-1...BKR-6 CIRCUIT BREAKER, PV-SA-1...PV-SA-6 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-M CIRCUIT BREAKER, PM-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 100A, SERVICE RATED, CIRCUIT BREAKER RATING: 100A AC-DSC-2 AC DISCONNECT SWITCH (EXTERIOR) 250V, 100A, NEMA-311, NON-FUSED REVISIONS Felakos, James d�S�Es' sr �., GREENLOGIC® 6285 New Suffolk Ave a��` ct Mattituck, NY 11952 A I' ¢* ENERGY 2.) REVISED TO REFLECT ASBUILT CONFIGURATION �q 021633 o ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION is Page 3 of 4 Drawing No: FLKS-3LD2A Revision: 2 Revised: 2/13/2023 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3,072 WATTS 211-264 VAC 12.80 A AC 240 V,AC PV-SA-2 3,072 WATTS 211-264 VAC 12.80 A AC 240 V,AC PV-SA-3 3,072 WATTS 211-264 VAC 12.80 A AC 240 V,AC PV-SA-4 3,072 WATTS 211-264 VAC 12.80 A AC 240 V,AC PV-SA-5 3,072 WATTS 211-264 VAC 12.80 A AC 240 V,AC PV-SA-6 3,072 WATTS 211-264 VAC 12.80 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 2" PVC-40 2 / 6 C THWN-2 2" EMT 2 / 6 D THWN-2 3/4" EMT 12 / 12 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE,DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM PROPOSED ELECTRICAL LOADS REVISIONS Felakos, James 6285 New Suffolk Ave ¢°�P °-� ENLOGIC Mattituck, NY 11952 ¢* ENERGY 2.) REVISED TO REFLECT ASBUILT CONFIGURATION \fi �Z1 3� o ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION 9Te of NE�� Page 4 of 4 Drawing No: FLKS-3LD2A Revision: 2 Revised: 2/13/2023 Pi�pJEC>T:;! ZONING BATA k REQUIRED REGULATIONS TAX MAP # IO00-II 15-6-50 SGTM#1000-115-6-;r:0;LOT AREA = 38,064 S.F.;R-40 NG ZONING DISTRICT R-40 NG ALLOWED E.:15T. PROP05ED COMPLIES LOT AREA 5£3,064 S.F. MINIMUM REQUIRED -" ---- FRONT YARD 40.0' 50.5' 505' YES FEMA FLOOD ZONE X " SIDE YARD 15.0' 20.0' 20.0' YES NETLAND5 DISTRICT N PERMIT # BOTH SIDE YARDS 35.0' N/A N/A N/A DEG DISTRICT N N.J. LETTER REAR 50.0' 1200, 1205 YES �- PROVIDED LOT SIZE 40,000 36 64. 38,064.0 NO si, i ate.. s ,:.. .j:i:;. .0 S.F. O S.F. S.F. - EXISTING PROPOSED LOT WIDTH 150.0' 102.8' 102.8' NO _ LOT DEPTH 1?5.0' 255 255.0' YES J FIRST FLOOR AREA 3460.0 3460.0 S.F. 3,636.-1 S.F. LIVABLE FLOOR AP.=A S.F. 3p91.3 S.F. \ BEDROOM COUNT 4 4 MAXIMUM PERMITTED BUILDING HEIGHT 35.0' 15.0' 15.0' YES NUMBER OF STORIES 2 1 1 YES \' 582°16'10"E 254.48' IS'SIDE YARD SETBACK PRINCIPAL I LOT'C.•0 ER' i^ " ri -- - -- - - - - -- - - - - - ---�- - - - T- BUILDINC,ENVELOFE N -I DESCRIPTION AREA % LOT I I GOVEf RAGE FRAME DECK 51 15 I I TOTAL LOT AREA -8,064.0 90' EXIST.I.G. I Sao S.F. POOL Ib'x32' i w w' a EXIST. Q EXISTING HOUSE 3,460.0 S.F. 4 FRAME O - ' 0ARAc5I� E EXI5TINO COVERED PORCH 164.1 S.F. 0.4% W w WI nom' DECK �; kn ju w -- [� I 71 ro o i EXI5TINO COVERED DECK 216.0 S.F. 0.6% i EXISTING POOL 8 DECK 1,202.0 S.F. 5.2% EXIST. I STORY I- FRAME HOUSE z $ GARAGE PR,P-PAVER w 2 I EXI5TINS GARAGE 5,76.0 S.F. 1.5% O _ _ PATIO AT GRADE 10- s---- - - - --�~ J I o o o l I TOTAL AREA OF ALL 5TR:UGTURES 5618.'1 S.F. 14.8% w a zrV I MAXIMUM COVERAGE ALLOWED = 20% I V .,PROPOSED ADDITION UNDER I - T• EXI5TIN6 COVERED PORCH I 51TE LAYOUT NOTES: PROJECT- "a, ROJECT-=y , 1. THIS 15 AN ARCHITECTS SITE PLAN d 15 I I SUBJECT TO VERIFICATION BY A LICENSED FELAKOS SURVE'r'OR. THE INFORMATION ' REFRESENTED ON THIS SITE PLAN IS TO THE RENOVATION ARCHIT OF KNOKLEDGE. 2.SURVEY T'5 BESTION WAS OBTAINED 40'FRONT YARD 5 TBAGK - PRINCIPAL WiLDINO ENVELOPE I� FROM,!,,SURVEY DATED NOVEMBER I,1-114 O AND PREPARED BY: 6285 NEW SUFFOLK AVENUE \ IN MATTITUCK,NY 11952 n 0 I� RODE¢IGK VAN TUYL \ s I°uI s OREENPORT,N.Y. 11,144 DRAWING TITLE.i SITE PLAN -- -- - - ----------- ---J PAGE: -N82°53'50"W 205.00 A-300 DATE 01/23/20 4 OF 9 SITE PLAN - - - SCALE.r-o• 1s'-o• " JAMES J. S TOUT A RCHITECT & Assoc. 2 GREG LANE EAST NORTHP ORT N. Y. 631 — e58 93 $ 8 Letter of Certification May 2, 2022 RE: Felakos Residence nn 6285 New Suffolk Avenue D �l Mattituck, NY 11952 JUN 1'0 2022 s BUILDING DEPT. TOW iV OF SOUTHOLD To whom it may concern: I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above- mentioned address and have determined the structure and the attachment to be adequate to support the new additional load imposed by the proposed solar system and complies with the 140-mph wind design load as per 2020 Residential code of NYS(RCNYS), 2020 Energy conservation construction code of NYS (ECCCNYS), and the ASCE 7-16. 9 I&6n n e(4- m(.(�•1 The existing 2"x 8"@ 24"o.c. roof rafters will provide adequate support. 1_� (Q�,a James J. stout APPROVED AS NOTED f DATE: Architect P.# FEE: BY: CU A CY OR NOTIii­ FY BUILDING DEPARTMENT AT Q CCC E IS UNLAWFUL REy�AIDC FOLLOWING ANSPECTIO NS:FOR THE TN �' 0 CE;RTIFIC �`�,P�� ST°�T���� ORNPOURED CONCCRE TQUIRED OC L PANCY 2, ROUGH FRAMING & PLUMBING , 3. INSULATION 4. FINAL - CON'STRU 'poN MUST BE COMPLETE c-;n c ,;}, ALL CONSTRUCTION SY,LL MEET THE C=NES REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR COM L WITH ALL CODES O DESIGN OR CONSTRUCTION ERRORS. W YO STATE & TOWN CODES S REQL IA ED AND CONDITIONS OF ELECTRICAL SOMOLD TOAW^ NINE BOARD INSPECTION REQUIRED SQ�� )STEES N.Y.S. Fr > EENL®GIC® �-� ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#A: Total System Size:20.16OkW Array Size:12.600kW 1 circuit of 11 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth:177° Pitch:18° Monitoring System: N SunPower Pand/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:66'3 7/8"X 20'7 3/4" Surface:69'7"X 23'4' Magic#:Invisimount Legend: ® 35 SunPower 360W Panels — SunPower Invisimount Rail x XIX • 60 Quick Mount E Lag 11 2x8 Douglas-Fir Rafter 24 0.G Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: P�D4 ftc'�� 5 J S TOS It ttl II�s�7J\ c1 S OF N�� . Drawn By:MADrawing#1 of 13 Date:4/29/2022 REV:A Drawing Scale:1/8"=1.0' 0EEINL®Glc° ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue attdudc,NY 11952 JOB MATERIAL LIST _ --- _ ._.. - Total System Size:20.160kW 1 circuit of 11 on a 20A breaker • 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 9 on a 20A breaker - - - ----.... ._ -._..__-- .__----- -.---.-•-- -.- .___. .___ _.__ _._ _.__.._..- _ ___.- --__ ---.__....-- ..-. -_.. __ _ _ ). lcircuit of8ona20Abreaker 1 circuit of 4 on a 20A breaker Azimuth:177° Material List QtV. Rail Material List QtY Monitoring system: N SunPower Pand/Array Specifications: Cast Aluminum Mounting Block w/Black Aluminum Flashing 93 ! Raddng sunPowerInvisimount 5/16"x7/8"EPDMSealing Plug 93 Panel:61.39"X 41.18" 5/16"x5.5"Hex-Head Lag Screw 93 - - Surface:73'3"x 86'8" - _ •._ _ Magic*Invisimount 3h 5/16"x1.25"Fender Washer 9 _.. _. _. . Legend: _._. . .. - 56 SunPower 360W Panels SunPower Invisimount Rail • 93 Quick Mount E Lag no 2x8"Douglas Fir Rafter 24"O.C. _.. ......:.... .. .. _. __.--...... _.. 2x6"Douglas Fir Truss 24"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seat: fl r Y J S/-p b C� Drawn By:MA Drawing#13 of 13 Date:4/29/2022 REV:A Drawing Scale:"=1.0' � GREENL®CIC® ENERGY GreenLogfc,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#A• Total System Size:20.160kW Array Size: 12.600kW 1 circuit of 11 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth:177° Pitch:18" Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-X22-360-E-AC 111141 VIN Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:66'3 7/8"X 20'7 3/4" Surface:69'7"X 23'4" Magic#:Invisimount Legend: ® 35 SunPower 360W Panels SunPowerinvisimount Rail • 60 Quick Mount E Lag Ij 2x8"OouglasFir-Rafter 247 O.C. /ty Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: ED q_.h'C 5 SiST hiT k! I; ]r� ^1633 Drawn By:MA Drawing#2 of 13 Date:4/29/2022 REV:A Drawing Scale:1/8"=1.0' G REE LOGIC" ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattitudc,NY 11952 Surface#A: Total System Size:20.160kW Array Size:12.600WV 1 circuit of 11 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth:177° Pitch:18" Monitoring System: N SunPower Pand/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount 1 1 2 Panel:61.39"X 41.18" Array:66'3 7/8"X 20'7 3/4" Surface:69'T'X 23'4" Magic*.Invisimount 1 3 2 2 Legend: ® 35 SunPower 360W Panels SunPower Invisimount Rail 3 • 60 Quids Mount E Lag 11 2x8 Douglas-Fir Rafter 24"O.C. 3 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: -e\ TO /TAN ..A �� T^ 2 33 �0 NE`N Drawn By:MA Drawing#3 of 13 Date:4/29/2022 REV:A Drawing Scale:1/8"=1.0' REENL®GIC° ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#B: Total System Size:20.16OkW Array Size:6.120kW 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:87" Pitch:18° Monitoring System: SunPower Pand/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 3/4"X 15'5 5/8" Surface:33'8"X 20'5" Magic#:Invisimount Legend: ® 17 SunPower 360W Panels SunPower Invisimount Rail • 25 Quick Mount E Lag -2x6"-Douglas-Fir-Truss 24°-O.Q Notes- Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: g J 5 T pG fj�a C) „, 21633 COQ' OF r\1111 Drawn By:MAS tDrawi g#4 of 13 Date:4/29/2022 1 REV-A Drawing Scale:1/8"=1.0' GREENLOGIC ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#B• Total System Size:20.160kW Array Size:6.120kW 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:87° Pitch:18° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 314"X 15'5 5/8" Surface:33'8"X 20'5" Ma is#:Invisimount Legend: ® 17 SunPower 360W Panels SunPower Invisimount Rail • 25 Quick Mount E Lag �f 2x6"Douglas-Fir Truss-247 O.C. IXI K I A\ j Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: 633 i _4 OP N E�iv Drawn By:MA Drawing#5 of 13 Date:4/29/2022 REV:A Drawing Scale:1/8"=1.0' , GREENLOGIC® ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#B: Total System Size:20.160kW Array Size:6.120kW 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:87" Pitch:18" Monitoring System: Z SunPower 4 Pand/Array Specifications: Panel:SPR-X22-360-E-AC Raddng:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 314"X 15'5 5/8" Surface:33'8"X 20'5" Ma is#:Invisimount 5 4 L end: ® 17 SunPower360W Panels SunPower lnvisimount Rail • 25 Quick Mount E Lag 8 2x6"Douglas Fir Truss 24"O.C. 5 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: ED ARC S J S TOC y/jam a 46 c • X21633 �� cO� Nem� Drawn By:MA Drawing#6 of 13 Date:4/29/2022 REV:A Drawing Scale:1/8"=1.0' EEL®GIC® ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#B: Total System Size:20.160kW Array Size:6.120kW 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:87° Pitch:18" Monitoring System: Z SunPower PanellArray Specifications: Panel:SPR-X22-360-E-AC Racking:SunPowerinvisimount Panel:61.39"X 41.18" Array:24'4 3/4"X 15'5 5/8" A= Surface:33'8"X 20'5" SFd L Ma is#:Invisimount OOJ9�a cis Legend: o ® 17 SunPower 360W Panels SunPower Invisimount Rail 04 • 25 Quick Mount E Lag fO Q 9j�s N 18 2x6"Douglas Fir Truss 24"O.C. % Notes: �� Nk Number of Roof Layers:1 N Height above Roof Surface:4" Materials Used:Quids Mount,SunPower 2x6 Douglas Fir Added Roof load of PV System:2.84psf Engineer/Architect Seal: ,-; c TpGy,T�C) 33 �L:T y `mac QF. NE`s Drawn By:MA Drawing#7 of 13 Date:4/29/2022 REV:A Drawing Scale:1/8"=1.0' 1I> REE L®GIC° ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#C• Total System Size:20.160kW Array Size:1.440kW 1 circuit of 4 on a 20A breaker Azimuth:87° Pitch:18" Monitoring System: SunPower Pand/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPowerinvisimount Panel:61.39"X 41.18" Array:6'11 1/8"X 10'3 1/2" Surface:41'3"X 18' Magic#:Invisimount Legend: o 4 SunPower 360W Panels — SunPower Invisimount Rail • 8 Quick Mount E Lag 01 24"Douglas Fir Truss 24"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf En 'neer/Architect Seal: C-MEDA a�ES J S?-, it ' 0 633 SID F NE Drawn By:M Drawing#8 of 13 Date:4/29/2022 REV:A Drawing Scale:1/8"=1.0' REEL®GIC® ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#C: Total System Size:20.160kW Array Size:1.440kW 1 circuit of 4 on a 20A breaker Azimuth:87° Pitch:18° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:V 11 1/8"X 10'3 1/2" Surface:41'3"X 18' Magic#:Invisimount Legend: o 4 SunPower 360W Panels SunPower Invisimount Rail • 8 Quick Mount E Lag 2x6"Douglas-Fir Truss-24°0.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf En 'neer/Architect Seal: z 633 yO� Drawn By:MA :gSof 13 Date:4/29/2022 REV:A Drawing Scale:1/8"=1.0' � EENL®GIC® ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#C: Total System Size:20.160kW Array Size:1.440kW 1 circuit of 4 on a 20A breaker Azimuth:87" Pitch:18" Monitoring System: SunPower 49 Pand/Array Specifications: ❑ Panel:SPR-X22-360-E-AC 6 Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:6'11 1/8"X 10'3 1/2" Surface:41'3"X 18' Magic#:Invisimount Legend: o 6 4 SunPower 360W Panels SunPower Invisimount Rail • 8 Quids Mount E Lag 00 2x6"Douglas Fir Truss 24"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: o� Ap b�Es J STCG> T� 11 v p ? 021633. Drawn By:`Nf �`Dr� rinD of 13 Date:4/29/2022 T .A Drawing Scale:1/8"=1.0' ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#C- Total System Size:20.160kW Array Size:1.440kW 1 circuit of 4 on a 20A breaker Azimuth:87" Pitch:18° Monitoring System: SunPower 1$ Pand/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" L Array:6'11 1/8"X 10'3 1/2" LL Surface:41'3"X 18' F CO) Magic#:invisimount CU Legend: 4 SunPower 60W Panels c p ° — SunPower lnvisimountRail 'fes �G j X 0 8 Quids Mount E Lag O Q ��T CV 10 2x6"Douglas Fir Truss 24"O.C. Notes: dN N Number of Roof Layers:1 T, Height above Roof Surface:4" Materials Used:Quids Mount,SunPower 2x6 Douglas Fir Added Roof load of PV System:2.84psf Engineer/Architect Seal: 5 c 7' oeS J S T .91 ^� 1633 CQ- Drawn By:MA brewing of 13 Date:4/29/2022 REV:A Drawing Scale:1/8"=1.0' No Vent Pipes Will Be Covered By The Solar Arra EElL®GIC® ENERGY Legend: GneenLogic,LLC Approved FelaAR-Access Roof AP-Access pathway,36" minimum width SVO—Setback at ride .lames p Y g 6285 6285 New Suffolk Avenue per R202 definitions per R324.6.1 as per R324.6.2.1 Mattituclk,NY 11952 Total System Size:20.160kW 1 circuit of 11 on a 20A breaker 1 circuit of 12 ona 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 4 on a 20A breaker Azimuth:177° Meter N 4 SunPower Monitoring System: svo 360W Panels SunPower Pand/Arra specifications: — Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Surface:73'3"X 86'8' 1 Magic#:Invisimount I I p Legend: 56 SunPower 360W Panels SunPower Invisimount Rail I I I I 1 • 93 Quick Mount E Lag I I IAPI InP I I 1 0 0 2x8"Douglas Fir Rafter 24"O.C. I I 1 00 2x6"Douglas Fir Truss 24"O.C. O 1 1 O svo 0 I Notes: -----------1 1-----------L _—— Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower I I Added Roof load of PV S I I ystem:2.84psf I Engineer/Architect seal: I ARC STDG 35 SunPower �-A 360W Panels svo 17 SunPower 360W Panels F N E`N Drawn By:MA Drawing#12 of 13 Date:4/29/2022 REV.A Drawing Scale:"=1.0' .... ._......_....._._..........__ _..._._ _....- - ......_..._._..._.._.._._....- - NEW EQUIPMENT......------_...__............_...._..._ ..._..... .....-- -........_.......................................... ..._._... -.... - - EXISTING SERVIC I PV-.SA-1 _q, AC-COMBINER PANEL 120/240, 1 PH, 3VV • '( AC-CMB-1 --- >PV LOADS ONLY) ( � P/ SA-2 ;1 400A (,K N M ruA V PV—SA-3 m JA% A B PI I✓ h • • • _ BKR-1 AC—DSC-1 �� . • . . AC DISCONNECT ', .� BKR-2 PV—+A—4rm- _ I h I ♦ • r 1 BKR-3 ; IV J BKR-d }�MAIN M- 1 rM • r • 1 s s • I BKR-5 A H N I v — rFUSEDFUSED PV—SA-6 _sit BKR-6 • • • � ® nig N • • • 2 1 5KR-7 EGC ( N PV—SA-7 N FF • • • —_— * • • 2 1EGC �� IV ECC EXISTING AC PAN LEXISTING GEC GEC CU _ 20.160kW DC 17.640kW AC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Felakos, Jim :; Ef ' 6285 New Suffolk Avenue G Mattituck, NY 11952 ENERGY ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Felakos-3LD1 Revision: 1 Revised: 3/24/22 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 8-MODULES PV-SA-2 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 8-MODULES PV-SA-3 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 8-MODULES PV-SA-4 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 8-MODULES PV-SA-5 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 8-MODULES PV-SA-6 PV SUB-ARRAY S P R-X2 2-3 60-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 8-MODULES PV-SA-7 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 8-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 2880 WATTS 211-264 VAC 11.70 A AC 240 V,AC PV-SA-2 2880 WATTS 211-264 VAC 11.70 A AC 240 V,AC PV-SA-3 2880 WATTS 211-264 VAC 11.70 A AC 240 V,AC PV-SA-4 2880 WATTS 211-264 VAC 11.70 A AC 240 V,AC PV-SA-5 2880 WATTS 211-264 VAC 11.70 A AC 240 V,AC PV-SA-6 2880 WATTS 211-264 VAC 11.70 A AC 240 V, AC PV-SA-7 2880 WATTS 211-264 VAC 11.70 A AC 240 V, AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Felakos, Jima 6285 New Suffolk Avenue GREENL1 Mattituck, NY 11952 ENERGY ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Pa e 2 of 3 Drawing No: Felakos-3LD1 Revision: 1 Revised: 3/24/22 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V,200A, NEMA-1,1-PH,3-WIRE BKR-1 CIRCUIT BREAKER,PV-SA-1 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-2 CIRCUIT BREAKER,PV-SA-2 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-3 CIRCUIT BREAKER,PV-SA-3 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-4 CIRCUIT BREAKER,PV-SA-4 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-5 CIRCUIT BREAKER,PV-SA-S MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-6 CIRCUIT BREAKER,PV-SA-6 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-7 CIRCUIT BREAKER,PV-SA-7 MATCH AC COMBINER PANEL BRAND,2-POLE,20A AC-DSC-1 AC DISCONNECT SWITCH(LINE TAP) 250V, 100A,NEMA-1,FUSED; FUSE RATING:100A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4"PVC-40 12 / 6 B THWN-2 2"PVC-40 4 / 6 C THWN-2 2"EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE,DISTANCE,AND DERATING FACTORS. 2.)ELECTRICAL CONDUIT TO BE MIN.PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Felakos, Jim 6285 New Suffolk Avenue Mattituck, NY 11952EN ERGS' ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Felakos-3LD1 Revision: 1 Revised: 3/24/22 SUNP WER SunP®wer®X-Series: X22-370 I X22-360 I II : SunPowero Residential AC Module Built specifically for use with the SunPower EquinoxT"'system,the only fully integrated solution designed,engineered,and warranted byone manufacturer. Maximum Power. Minimalist Design. "e sirs AVO WA Industry-leading efficiency rneans more power and savings per available space.With fewer modules required and hidden microinverters,less is truly more. L �� Highest Lifetime Energy and Savings. Designed to deliver 60%rnore energy over 25 years in real-world conditions like partial shade and high temperatures.! Fundarir'rentiiilly Different.. a And Better. a up to > 1,Gs5 600% ,o more e ;lifetime ear, (energy LnN 0 10 15 20 25 The SunPower�,'Maxeon,"Solar Cell nears of operation • Enables highest efficiency modules avalabie . • `Unmatched reliability' • . it.ented soR4 metal founda:ic,r; Best Reliability. Best Warranty. prevents breakage andcorrosion With more than 25 million modules deployed around b..0 . the world,Sur Power technology is proven to last.That's why we stand behind our module and microinverter 14 with the industrls best 25-year Combined Power and m Product Warranty,including the highest Power Warranty in solar. Factory-integrated Microinverter' 1r ;; i • Simpler,ester installation c 0 ee„ • Irtegratei wire manageryient, rapid shi:tdown 92% • r�ngirteered and eallbrated:;y' E 90i, 112% ,o Wt more Sun',ower for Sun ower modules c :Power In year � Y2Y5 ! J25 Years of operation D. X-Series:X22-370 ( X22-360 SunPowery'Residential AC Module I AC Electrical Data Inverter Model:Enphase IQ 7X5(IQ7XS-96-ACM-Us) @240 VAC @208 VAC --- -- -....._........_........... Peak Output Power 320 VA 320 VA _...._....__.._..............................................................................................................................................................................._._.__.................................................................... .. . _..-.._.............................._......................_. .. .._.......................................__.-..........................._.................._.......... Continuous Output Power 315 VA 315 VA _..- -.._...._..__....._........_..._...._._....._._.._........._.........._._..._...._............__..- ._.............-- --........... _. _..-- Norn.(L-Q Voitage/Range'cv) 240/211-264 208/183-229 IAI ax.ContInjou s Output Can'rent(A) 1.31 1.51 j t•1ax.Units per 20 A(L L)Branch Circuit' 12(single phase) 10(two pole)Wye ;- -----.....-----.....__..__._.......-----------....._..........................._......._.._................_.........._.........._........._._........................._.---- --....._................----...._...._.......................... CLC:We.ignted Efficiency 97.5`x!0 97.0% - - - -..._........................._....._...----.-._.._...._....._.....-...._..._....-....__........................._....- ------.._......_.........---- - -._.._......-.._. I Nom.Frequency 60 Hz Extenders Frequency Ram e 47-68 H7 ;;C Snort stall(Fat!It Current C ver 3 Cycles 5.8 A rrns -_...._. .. Overvoitage Class AC Por III -. -..- -............... _......... -- --- C Port Bac fie d Carrera 18 rnA -- --..-..................._...-_._..._.........._......... .. ..................._...._....----..__. Pnwer Factc;r Setting1.0 . ......_............................_..............._....----.._.._....... .._._..-.._._..-- -._.._......._...................._.................._...-- -.._..---- ---. I Porre•r=actor(adjustable) 0.7 lead./ 0.7 lag. _......_..__.....__..._....._....._..._..........._..._..__......_..._..._._....._....__....._......_...._.._..._....._...---.................. _...._........_.................__......................................._..._.-..__............_...._._........._....... ......................_...---_.......... No active phase balancing for three ptiase instal a*.ions --- DC Pow e Data Warranties,Certifications, Compliance SPR-X22-370-E-AC SPR-X22-360-E-AC I ,warranties 25-year limited powerwarrany - Nominal Power`'(Prom) 370 W 360 W 25-year limited product warranty --------- -- I • Power Tolerance +5/-095 +5/-0% UL 17031 CertificationsUL 1741/IEEE-1547 Module Efficiency` 22.795 22.1% I UL 1741 AC Module(Type 2 fire rated) and! e'. Temp.Coef.(Power) -0.29`WIC- -0.29%/°C !CfI, ince UL 52109-1/IEC G2109-2 i i FCC?art 15 Class B •Three bypass diodes ICF.S-0003 Class B Shade Tolerance •Integrated module-level maximum CAN/CSA.-022.2 NO.107.1-01 power point tracking CA Rule 21 (UL 1741 SAY! -- - -- (includes VoltNar and Reactive Powf_'r Pdarity) Tested Operating ConditionsUL Listed PV Rapid Shutdown Equiprnent' Operating Temp. -40°F to+140°F(-40°C to+60°C) _..-. _......_.............................. Max.Ambient Ternp. 122°F(50°C) Enables installation in accordance with: NEC 690.6(AC module) Max.Load Wind:62 psf,3000 Pa,305 kglm1 front&back NEC 690.12 Rapid Shutdovrn(inside and outside the array) Snow:125 ps,5000 Pa,511 kg/m7 front NEC 690.15 AC Connectors,690.33(A)-(E)(1) Impact Resistance 1 inch(25 nim)diarr!eter hail at 52 rnph(23 m/s) _-_-__.....-..-.....................__.... ..............._.._....__......__-....---------.--....._..._..._....__._.._.._........._......_._............_......__....... When used with Invisilviour racking and InAsiMount accessories b (UL 2703): Solar Cells 95 iAonccrystalline Maxeon Gen III Module grounding and bonding through Invis!Mount ------......._.........._. _ ......._............. ... . .................._................__...................................... Class A fire rated Front Glass High-transmission tempered glass'with When used with AC'module Q Cables and accessories(UL 570'and anti-reflective coating - UL 2238)5: ----- �--- - - ---- Environmental Rating Module:Outdoor rated ! Rated for load break disconnect Inverter:NEMAT'pe 6 Class II 1 PID Test Potential-induced degradation free I f--tame Class'i black anodized(highest AAMA rating) --..__................-._--- --...--_.-......__..............._....._...-_-- -.-.-__.__............., I Weight 42.9 ib(19.5 kg) m 6t ia. : ..-.............._------_....._.....__ .._.---------------........._------------------------------------------------------------------------_........._ ..._...._.............. Recornn,iended Max. I � I Module Spacing 1.3 in.(33 mm) SunPower.360 W compared to a conventional module on same•sizod arrays(260 W,15% I (Urn) cfficienc,approx.1.6m'),4,6rnareenergyoerwatt(basedonthird party module cha r,.acter izat ion and PvSim),0.7515/yr slower degreda tion(Campeau,Let at."Sun Power Vioduie Degradation Rate,"Surl Power white paper,2013). • 1046 Milt � znMM . 2i3asc;donsearchefdansbee[vah)esfromwebsit.esof[opl0mam�facat:rersperlHS,asof January 2017, 3rtrankin"Fr aunhoferPVDurabi!ityinitiativeforSol arMod ules:Part'3."PVTecaPowe r " ............'"--""" Magazine,2015.Campeau,Z.et al.'Su n Powe r IVordule Degradat ion Rate;'SunPowerwhitt. oa?)er,2013. 343 mm i -1r.acforysetto1547a-2011.defauh:settirgs.C'ARule21 defaultsettings profilesetduring tt9S inti co:nmissionirg.sr-e tha Equino c lnstal!ation Guide#S'18't 0 i for more information. S.Standard'RstCcnditions(1C)00W/m%irrtrdiance,AM1.5,26°Q.NRf::l.calihra[ion �,_ _ � ____._.1 standai d:SOF'S r urrenc,iACCS FFand voltage..All DCvoltage is fully cor•u ned within the ^nodule. 437 mrn _ 6 This product is UL Listed as PVRSE and c:onfor nis with NEC 2014 and NEC 2011690.t2; � (17.1 IN and 022.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors;, when mstaUed according to manufactureils Instructions. O¢nanxe GFIDAT�CRTMNV See more npou see extended for mere.reference Information. wer.tion. w ,N (t r ^p� For more details,see extended da*:asheet nanv.sunpotver.com7da[asheets LISTED�� �„\,/ C K Specifications i nduded in this datasheet are subject to change without notice. ,0201851 in?owerCorporation.AII Rights Renewed.5UNPO'MER,the Module FirePedam .Type 2 SUNPOWERiogo and MAXEON are registered trademarks of 51.10ower Please read the Safety and Installation InStructionsfor details. 531945 RevA Corporation in the U.S.and other countries as well.1-800-SUNPOWER. sunpowe-r.com `,p. .i'. .�`"wU�'.:�� � ",°"•.�s..,� x<�. ., :TSF Simple and Past Installation Integrated module-to-rail grounding Pre assembled mid and end clamps j i Devitating mid clamp for easy placement i F' Mi d clamp width facilitates consistent,even module spacing _ �'�.��. •�- ; m.���. �_ ,��. Simple,pre-drilled rail splice UL 2703 Usted integrated grounding Flexible Design � Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle rnanagernent Customer-Preferred Aesthetics ,1#1 module and#1 mounting aesthetics Best-in-class system aesthetics Elegant Simplicity Premium,low-profile design Black anodized components SunPower"' InvisiMount m is a SunPower-designed Hidden mid clamps and encs`clamps rail-based mounting system. The InvisiMount system and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior aesthetics. Built for use with SunPower DC and.AC modules The InvisilMount product was specifically envisioned and Gest-in-class system reliability and aesthetics Combine with SunPower modules and engineered to pair with SunPower modules.The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for-both homeowners and installers. s a top Di _ sunpower.com Datasheot, ® • +T dr .�' �+ �zri £'�'., T;,'&'�wP%�ti,''^Y,a ,�i .,,,,,';,,��.� �4 •� ��`0. �': ., ..I)i" T ra� 4, �,�s�, sw'' �:sa•• .r 3 Module*!Mid Clanip and Pail Module*/End Clamp and Rail Y ff `7Z eM Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly End Cap a a0 Q� ® �q� • # Temperature j -40°C to 90°C(-40°F to 194°F) Component Material Weight ___ 3000 Pa uplift — . _......................_....----..................._.._. Max.Load(LRFD) i Md Clamp Black oxide stainless steel AISI 304 63 g(2.2 err.) 6000 Pa downforce End Clamp Black anodized alurninurn=alloy 6063-T6 1 10 g(3_33 07) j Rail Black anodized aluminum alloy 6005-T6 8.30 g/r1-i(9 0z/fC) s 8 Rail Splice Aluminum alloy 6005-T5 330 g rn(9 oz/ft) 25-year product Warranty ...._..._.._._..__.,__.. ._.. .............................. ............................................................................................................ .......... Warranties GfOUnd big 304 stainless N arras les Assembly (A7-70 bolt;tin-plated copper!ug) '06.5 g/m(3.75 oz) 5-year finishwarranty - — --............ .....--._...__._...... ---- —.End Cap Black acetal(POM)copolymer 10.4 g(0.37 oz) j ---._.----- I UI.7703 Listed Certifications l a ® Class A Fire Rated �^ a� Composition Shingle Rafter Attachment plication Composition Shingle Roof Decking Attachment Pp Curved and Flar Tile Roof Attachment Universal Interface for Other Roof Attachrrlents Refer to roof attachment hardware manufacturers documentation. *Module frame that is compatible with:the InvisiMount system required for hardware intel'operability. ,U 2015 SunPower Corporation,All Rights Reserved. SUNPOWER.the SUNPOWER logo,and iNVISIMOUNT are trademarks or registered trademarks of SunPower Corporation.All other trademarks are Elie property of their respective owners. sunpcy:•jer.com Specificatons included in this datasheet are subject to change without notice. Document#509506 Re< _ y J A M E S J. S TOUT A R C H I T E C T & Assoc. 2 G REG L ANE E AST NORTHPORT N. Y. 831 - 8 58 9388 Post Installation Letter August 8, 2022 RE: Felakos Residence 5285 New Suffolk Avenue Mattituck, NY 11752 To Whom It May Concern: This letter is to confirm that as of this date August 8,2022 I,James J Stout, NYS license 021633 have personally inspected the placement and installation of the roof top solar panels at the above listed address. The solar panels have been installed as per manufacturer's guidelines and specifications. The racking system design and installation complies with the 2020 NYSRC and 2020 NYSUCS building code and provisions of ASCE 7-16. The installation was done as per As-Built plan. Thank you for your cooperation in this matter. James J. Stout Architect ARC des s io 'yip Q� �Pn G� �0 1 Ft7{ �2 V X0 F N E�(�l REENL®GIC® ENERGY G lakes,James LLC Approved mes 6285 New New Suffolk Avenue Mattituck,NY 11952 Surface#A` OCT 2 1 2022 Total System Size:20AOOkW Array Size:13.600WV 1 circuit of 8 on a 20A breaker ]BIDING DEPT. 1 droit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker TOWN OF SOUTH®LD 1 droit of 8 on a 20A breaker Azimuth:177° Pitch:18° Monitoring System: N SunPower Pand/ArraS cificabons: Panel:SPR-M425-H-AC Raddng:SunPower Invisimount Panel:73.7"X 40.6" Array:65'1 3/4"X 20'7 3/8" Surface:69'T'X 23'4" Ma is#:Invisimount Legend: ® 32 SunPower 425W Panels — SunPowerinvisimount Rail • 86 Quids Mount E Lag f 8 2x8"Douglas Fir Rafter 24"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ARC f 5 SEs J S7- 0 7- 0 633R O N � Drawn By:MA Drawing#1 of 9 Date:6/8/2022 REV:A Drawing Scale:1/8"=1.0' r,� ��l LOGIC' ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#A: Total System Size:20.400WV Array Size:13.600WV 1 circuitof 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 dreuit of 8 on a20A breaker 1 drevit of 8 on a 20A breaker Azimuth:177" Pitch:18" Monitoring System: N SunPower Pand/Array Specificadons: Panel:SPR-M425-H-AC Racking:SunPowerinvisimount Panel:73.7"X 40.6" Array:65'1 314"X 20'7 3/8" Surface:69'T'X 2347 Magic M Invisimount Legend: ® 32 SunPower 425W Panels — SunPower Invisimount Rail • 86 Quick Mount E Lag 09 2X8"Douglas Fir Rafter 24"O.C. Notes: Number of Roof Dyers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: \��ED ARO 0Es J S,o yiT it �F NE`N`1 Drawn By:MA V Drawing#2 of 9 Date:6/8/2022 REV:A Drawing Scale:1/8"=1.0' h GRSE I ILOG IC® ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#A: Total System Size:20.400WV Array Size:13.600kW 1 draft of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 dreuit of 8 on a 20A breaker Azimuth:177° Pitch:18° Monitoring System: N SunPower Pand/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount 1 1 X 1 2 Panel:73.7"X 40.6" Array:65'13/4"X 20'7 3/8" 1 3 2 Surface:69'7"X 23'4" Magic#.Invisimount 3 Legend: 1 ® 32 SunPower 425W Panels AIEE —114E 4 — SunPower Invisimount Rail • 86 Quick Mount E Lag 4 H 2x8"Douglas Fir Rafter 24"O.C. 4 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.31 psf En 'neer/Architect Seal: `,�¢ED ARC f�.5 SES J S/-0 y�j 9 , 63 �O er a OF N�`� Drawn By:MA Drawing#3 of 9 Date:6/8/2022 REV:A Drawing Scale:1/8"=1.0' GELOGIC° ENERGY GreenLogic,LLC Approved Fdakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#B: Total System Size:20.400kW Array Size:6.800kW 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:87" Pitch:18" Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-M425-H AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:24'9"X 17'2" Surface:33'8"X 20'5" Ma is#:Invisimount Legend: ® 16 SunPower 425W Panels SunPower Invisimount Rao • 42 Quids Mount E Lag 10 2x6"Douglas Fir Truss 24"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: C��ED ARcy �5 ESJSTO Y JSP •i`+,` 1a;_' 633 Drawn By:MA Drawing#4 of 9 Date:6/8/2022 REV:A Drawing Scale:3/16'=1.0' ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#B: Total System Size:20.400kW Array Size:6.800kW 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:87" Pitch:18° Monitoring System: 2 SunPower Pand/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPowerinvisimount Panel:73.7"X 40.6" Array:24'9"X IT 2" ZZA Surface:33'8"X 20'5" Magic#:Invisimount L end: ® 16 SunPower 425W Panels — SunPower Invisimount Rail • 42 Quick Mount E Lag H 2x6"Douglas Fir Truss 24"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ly �R�D gRcy - �C 1 I , meq 02 . 33 y0� Drawn By:MA Drawing#5 of 9 Date:6/8/2022 REV:A Drawing Scale:3/16"=1.0' ` ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#B: Total System Size:20.400kW Array Size:6.800kW 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:87° Pitch:18° Monitoring System: 5 SunPower Pand/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPowerinvisimount Panel:73.7"X 40.6" 5 Array:24'9"X 17'2" Surface:33'8"X 20'5" Magic#:Invisimount Legend: 6 ® 16 SunPower 425W Panels — SunPower lnvisimountRail • 42 Quick Mount E Lag 6 0 B 2x6"Douglas Fir Truss 24"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" 6 Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.31psf Engineer/Architect Seal: C��ED aRe ��5 SES J S TC y�T �. NEIN Drawn By:MA Drawing#6 of 9 Date:6/8/2022 REV:A Drawing Scale:3/16"=1.0' R EE---9%1I L®G I C® ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue Mattituck,NY 11952 Surface#B: Total System Size:20.400kW Array Size:6.800kW 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:87" Pitch:18" Monitoring System: SunPower ,Lp 5 Panel/Anray Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7'X 40.6" Array:24'9"X 1 T 2" L- Surface:33'8"X 20'5" aSF�� L Magic#:Invisimount Cu ® Legend: 16 SunPower 425W Panels 2 +SlO 0 — SunPower Invisimount Rail • 42 Quick Mount E Lag H 24"Douglas Fir Truss 24"O.C. T. % Notes: Number of Roof Myers:1 N Height above Roof Surface:4" �• Materials Used:Quids Mount,SunPower 2x6 Douglas Fir Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ARc J S 'tl t 021 , �3 O JF NEIN Drawn By:MA Drawing#7 of 9 Date:6/8/2022 REV.A Drawing Scale:3/16"=1.0' No Vent Pipes Will Be Covered By The Solar Arrav GREEL®GIC® ENERGY Legend: GreenLogic,LLC Approved Fdakos,James AR-Access Roof - AP-Access pathway,36"minimum width SVO—Setback at ridge 6285 New Suffolk Avenue per R202 definitions per R324.6.1 as per R324.6.2.1 Mattituck,NY 11952 Total System Size:20.400kW 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:177° Meter Monitoring System: N SunPower Pand/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPowerinvisimount Panel:73.7"X 40.6" Surface:73'3"X 86'8" Magic*Invisimount Legend: • 1 48 SunPower425W Panels I — SunPower Invisimount Rail I • 128 Quids Mount E Lag IAP I 00 2x8"Douglas Fir Rafter 24"O.C. 1 00 2x6"Douglas Fir Truss 24"O.C. a o I svo --------------�--------r Notes: Number of Roof Layers:1 Height above Roof Surface:4" 2 Materials Used:Quids Mount,SunPower 11 Added Roof load of PV S 1 1 ystem:2.31 psf 1 Engineer/Architect Seal: I SES J S7- 32 T32 SunPowerA 425W Panels svo 16 SunPower Nj 425W Panels 0 Drawn By:MA\J Drawing#8 of 9 Date:6/8/2022 REV:A Drawing Scale:1/16"=1.0' GR EEN LOGIC' ENERGY GreenLogic,LLC Approved Felakos,James 6285 New Suffolk Avenue JOB MATERIAL LIST attitu ,N 1 952 Total System Size:20.400kW 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker - -. .. '. . ... _ .. 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:177° Material Listtg,y_. Rail Material List Qty Monitoring System: N SunPower Pand/Array Specifications: Cast Aluminum MountingBlockw-/Black Aluminum Flashing 128 — Panel:SPR P25-H'AC ------ Racking:Sun ower vis imount 5/16"x7/8" EPDM Sealing Plug 128 Panel:73.7"X 40.6" - - rr -.-; ---- - ;--- ---- ----- -, - - --- - - -- Surface:73'3"X 86'8.. 5/16 x5.5rr Hex-Head Lag Screw 128 _-- _ Magic#:Invisimount 5/16"x1.25"FenderWasher 128 Legend: I I 48 SunPower425W Panels SunPower Invisimount Rail • 128 Quick Mount E Lag _ ue 2x8"Douglas Fir Rafter 24"O.C. 2x6"Douglas Fir Truss 24"O C . Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: D ARc .4 � i •j��il c�l 9 �0 1633 �0 Drawn By: Tlir��In_g #9 of 9 Date:6/8/2022REV:A Drawing Scale:1/16"=1.0' VLA U V I OCT 2 1 2022 --------------------NE:^r EQUIPMENT -------------- EXI`✓:TIidG SERVICE I-------- s ,T�1T� v �. ----- f�< 120; »0, 'I FH, 31N 'SOW i OF SOU T OLD TY.%ICf TMFI4 SCHEMATIC, --- INSTA(.2ATi0C:4L�Y VAR-, RMUI.RM LOCAL s}iJ /�/ L\ ANO IMU€TY APPROVAL) i 300AI \�Vi`I € j I I PV--.SA—', _ ^":q% AC—COMBINER PANEL ._. . . . AC—CK1B-1 AC—DSC—'L AC—DSC—i — ._...__..................__... ---i (PV ONLY) E3% N 2 3 ( AC DISCONNECT AC DISCONNECT ' ;l -- —� (EXTERIOR) (TAP SWITCH) � �• � I TYP. PV ARRAY ^ I 1ODA MAIN �\ I PV—SA Pfl, I A P. BKR—'. . . . 2 ' ;' i rt MAIN �r�Pf.Aa4 ----- "—` i-1 I BKR—N TYPICAL PV MODULE V, I I NON.- L i INTEGRAL DC/AC INVERTER I I PllSEI; FUSED I I� BKR—M II i IEGC _ i I I N PM_I � EGC ;^ : I i I I7 MAIN C/T` ! AC DISTRIBUTION I i AC DISTRIBUTION j I I I f Iv 14' ECC I (NON—CRITCAL LOADS) (NON—CRT^ L LOAD 'I --------- --------------- ' #6CU PMN.; _ -----------------.i--------- ------.---J IRREVERSIBLE BOND, TYP. i EXISTINGC,EC PROPOSED 3-LINE ELECTRICAL DIAGRAM Felakos, James REVISIONS 6285 New Suffolk Aveco* 1O Mattituck, NY 11952 ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION ELIMINATING THE COST'OF ENERGY Pagel of 4 Drawing No: FLKS-3LD1A Revision: 1 Revised: 9/26/2022 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 20.40 (PV) TOTAL PV KW RATING: (DCPOWER) 18.432 (PV) QTY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL: SPR-M425-H-AC 48 PV MODULE: 425 W DC(NOMINAL), EACH SUNPOWER BRAND, MODEL: SPR-M425-H-AC 48 PV INVERTER: (INTEGRAL TO MODULE) 384 VA, 1.45 A, 240V AC, EACH REVISIONS Felakos, James � 6 6285 New Suffolk Ave E L Mattituck, NY 11952 ������ _ ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 2 of 4 Drawing No: FLKS-3LD1A Revision: 1 Revised: 9/26/2022 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 10-MODULES PV-SA-5 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 10-MODULES PM-1 PRODUCTION MONITOR SUNPOWER PVS-6 AC-CMB-1 AC COMBINER PANEL, CRITICAL LOADS 250V, 200A, NEMA-1, 1-PH, 3-WIRE BKR-1...BKR-5 CIRCUIT BREAKER, PV-SA-1...PV-SA-5 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-M CIRCUIT BREAKER, PM-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1AC DISCONNECT SWITCH (LINE TAP) 250V, 100A, NEMA-1, FUSED; FUSE RATING: 100A AC-DSC-2 AC DISCONNECT SWITCH (EXTERIOR) 250V, 100A, NEMA-311, NON-FUSED Felakos, James REVISIONS - 6285 New Suffolk Ave tF ;` �'.' GREENLOGICO Mattituck, NY 11952 ' ENERGY ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 3 of 4 Drawing No: FLKS-3LD1A Revision: 1 Revised: 9/26/2022 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3072 WATTS 211-264 VAC 11.60 A AC 240 V,AC PV-SA-2 3840 WATTS 211-264 VAC 14.50 A AC 240 V,AC PV-SA-3 3840 WATTS 211-264 VAC 14.50 A AC 240 V,AC PV-SA-4 3840 WATTS 211-264 VAC 14.50 A AC 240 V,AC PV-SA-5 3840 WATTS 211-264 VAC 14.50 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 2" PVC-40 3/0 / 2 C THWN-2 2" EMT 3/0 / 2 D THWN-2 3/4" EMT 12 / 12 1.) CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM PROPOSED ELECTRICAL LOADS REVISIONS Felakos, James GREE WGIC 6285 New Suffolk Ave Mattituck, NY 11952 ENERGY- ELIMINATING TWIGOST OF.ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 4 of 4 Drawing No: FLKS-3LD1A Revision: 1 Revised: 9/26/2022