Loading...
HomeMy WebLinkAbout41352-Z S11ff0rt Town of Southold 3/11/2023 a y� P.O.Box 1179 W ---C 53095 Main Rd �y� oar Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43914 Date: 3/11/2023 THIS CERTIFIES.that the building WIRELESS COMMUNICATION SYSTEMS Location of Property: 1040 Horton Ln, Southold SCTM#: 473889 Sec/Block/Lot: , 63.-1-10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/29/2014 pursuant to which Building Permit No. 41352 dated 2/8/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: wireless communications facility for AT&T as applied for. The certificate is issued to Cubesmart LP of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41352 6/7/2017 PLUMBERS CERTIFICATION DATED th ri d ignature o�gUFFo��,co TOWN OF SOUTHOLD �� oy BUILDING DEPARTMENT . C2 2 TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41352 Date: 2/8/2017 Permission is hereby granted to: Cubesmart LP PTA-CS # 658 PO BOX 320099 Alexandria, VA 22320 To: install a wireless communications facility as applied for per planning board approval. At premises located at: 1040 Horton Ln SCTM # 473889 Sec/Block/Lot# 63.-1-10 Pursuant to application dated 2/8/2017 and approved by the Building Inspector. To expire on 8/10/2018. Fees: WIRELESS COMMUNICATIONS -NEW FACILITY $750.00 -COMMERCIAL $50.00 o a . $800.00 Building n ector 1 pF SO(/��Ql Town Hall Annex Telephone(631)765-1802 54375 Main Road y ,r Fax(631)765-9502 P.O.Box 1179 aQ roger.richertR-town.southold.ny.us Southold,NY 11971-0959 Q COUNT`1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Cubesmart LP (AT&T LI - 1025) Address: 1040 Horton Lane city:Southold st: New York zip: 11971 Building Permit#: 41352 Section: 63 Block: 1 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: EECO Electric License No: 54281-ME SITE DETAILS Office Use Only Residential Indoor X Basement Service Only Commerical X Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200A Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer RecptEmergency Fixture Time Clocks Disconnect 200A Switches Twist Lock Exit Fixtures TVSS Other Equipment: 200A Underground Service Notes: Inspector Signature: Date: June 7, 2017 0-Cert Electrical Compliance Form.xls �590000, �,of so�T �.� y0l coUNi'1,N`� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE 1° INSPECTOR ` soulyo coUNTI,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION [ ] FRAMING / STRAPPING [ FINAL 14)1#104W 7;WZl-"'o [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: l IM//l/ in�A'fi �h ecL c/ AS '�' . DATE S INSPECTOR OFFICE LOCATION: MAILING ADDRESS: Town Hall Annex ,\\OFSO(/T�O P.O. Box 1179 54375 State Route 25 hQ �� Southold, NY 11971 (cor. Main Rd. &Youngs Ave.) Southold, NY Telephone: 631765-1938 u> >c www.southoldtownny.gov G • �Q COU PLANNING BOARD OFFICE TOWN OF SOUTHOLD October 25, 2017 D OCT 2 5 2017 John Coughlin, Esq. c/o R6, Nielsen, Huber & Coughlin, LLP BUILDINGDEPT. 36 North New York Avenue TOWN OFSOZTTHOLD Huntington, NY 11743 Re: Proposed Site Plan for New Cingular Wireless/AT&T at 1040B Horton's Ln. 1040B Horton's Ln., ±400'n/o Traveler St. & Hortons La., Southold SCTM#1 000-63-1-10 Dear Mr. Coughlin: The Planning Board has found that the requirements of the above-referenced Site Plan have been completed based on the site inspection made October 13, 2017 and the Work Session held on October 16, 2017. The site is now in conformance with the Site Plan entitled "AT&T @ 1040B Hortons Lane", prepared by Malick & Scherer, P.C. on January 21, 2010 and last revised April 2, 2015. This letter does not condone any changes from the approved Site Plan and from approvals permitted by other agencies; Planning Board approval is required prior to any significant changes to the site. Please, if you have any questions regarding this site plan or its process, do not hesitate to call this office at 631-765-1938. Respectfully, 4 Donald J. Wilcenski Chairman cc: Michael Verity, Chief Building Inspector Jamie Richter, Town Engineering Inspector 416. ' ``P y -70 411 * I i 01 AO tv Ito ♦ I 4f - ♦i /, 40f 6 Ol - " r ~ a.- - 7171- 7 t f l J e f .r j 1 •.J� _�C � 1 _r 1 . 1 a ii �-� r _ •tet ;*: 41 } � _�' �-' . f loom Ow "es IW JmwHrA t Alt. k •r i' I Amw. . law via P4 *IWWW r 'r•'��''� �'fib !'• 1 ;w ��l� t � � •'," :. T pr tea. Will , N' i r 1 r IL i F r1 00 ; r 1 1 vr • "ar AV � ic s b live i " 56 , r i .w 1 1 :1 k t i qp .. J6_ WW 40 • � r • r � r • � �ty Oro • ,..t., a c .4 .,� ,► mu t r foe 1 N , r k ;r.1r ftAftj op ik ted bit 1 • 1 T Top & BOTMy IDUMAM ML ar- m dMR�tR M1t� +t'+'� a r-ar 41tW w$ ion rs '+' Ii"M.•7IfW ws i Fr cot 1 L VAM ��eeeeeeee_ '* ��� �. r MMA R Map ap Y IPA= M04 Rd Y wit. MlN1 M PAW WAO O&Y. HJH.M (6) 05 WRZ04TAIL TU rte' f24 SPA= µ V-- 915) iTAL REQ TW & SOT, (g4) Vr& 7 it i � x * r � r • • • rQ • re IMULATION STATE BNEROY COM 11Vl"A:4 fA .al-M PAM MIM-, �l b� e�if'e•�R�i v��7•i 1. � 1.�yr !� �w � • � A,� ��� �� ^ ,,.. r TOWN F SALJFH_ LD BUILDING PERMIT APPLICATION CHECKLIST B=DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 / Survey SoutholdTown.NorthFork.net PERMIT NE ` ` — ,heck Septic Form N.Y.S.D.E.C. --� Trustees p r Flood Permit Examined / J _ _ -:Storm-Water Assessment Form ----1 Contact: Attorney for Applicant: Approved_ ,20�_ Mail to: Re,Nielsen,Huber&Coughlin,LLP Disappro ed JO l 36 N.New York Ave.,Huntington,NY 11743 Phone: 631-425-4100 BLDG. DEPT, Expiration 20 TOWN OF SOUTHO ng Inspector CATION BUILDING PERMIT 20 %�( INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered b��,this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. New Cingular Wireless PCS,LLC("AT&T") (Signature of applicant or name,if a a mpo thm) Limited Liability Company 440 Hamilton Avenue,White Plains,NY 10601 (Mailing address of applicant) State whether applicant is owner, lesse agent, architect, engineer, general contractor, electrician,plumber or builder Applicant is Lessee Name of owner of premises YSI XXXII, LLC Limited Liability,Company (A$on the tax roll or latest deed) If alcgnt is a signature, f dul authorized officer. Ne Cm ular Wire e , By- (Name and title axpoxattx)6-. ieex) Kevin J.Russ,PMP,Area Manager-Constru:tion&Engineering Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which propose l work will be done: 1040-B Hortons Lar: ; Southold House Number Street Hamlet County Tax Map No. 1000 Sectic -1 63 Block 1 Lot 10 Subdivision Filnd Map No. Lot 2^ State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Public storage facility b. Intended use and occupancy Same as above with Public Utility Wireless Telecommunications Facility 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Applicant proposes to replace the existing flagnole with proposed public utility wireless telecommunications unipole,install antennas MescjiRtiorl therein, tns a1�11 related equt ment inside existing building,and ' stall related generator, all as depicted i e p a s su mitted 4. Estimate osM%�1.t�-CAS ee herewith. (To be paid on filing this application) 5. If dwelling, number of dwelling units N/A Number of dwelling units on each floor N/A If garage, number of cars N/A 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. Public storage facility 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Existing one-story storage buildings to remain unchanged; Existing 40'+/-flagpole to be removed Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction*Front Rear Depth Height Number of Stories Proposed 72'unipole to be installed on T planter/caisson(Total height at 6.94+/-acres 75'+/- Approx.300 sq.ft.equipment room in building;and 9. Size of lot Front Rear - Depth approx.31.62 sq.ft.concrete pad for generator 10. Date of Purchase June 18,2009 Name of Former Owner U-STORE-IT,L.P. 11. Zone or use district in which premises are situated Light In 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO_X 13. Will lot be re-graded? YES NO Y Will excess fill be removed from premises? YES NO y(10 6 S00deS4/1r4 RICL I gul-M 3dVD 14.Names of Owner of premises YSI XXXII,LLC Address (, gone, FA 190?7Phone No. qo1-9222look-1 Name of Architect Malick&Scherer, H P.C. Address Frotita 8�s yte 260 phone No 908-537-1300 . amptonr Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO x * IF YES, D.E.C. PERMITS MAY BE REQUIRED. .. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES x NO� * IF YES, PROVIDE A COPY. STATE OF NEW YORK) n� COUNTY OF SASS: WN ) Kevin J. Russ being duly sworn,deposes and says that(s)h: is the applicant (Name of individual signing contra A)above named, (S)He is the Kevin J. Russ,PMP, Area Manager - Construction&Engineering for New Cingular Wireless PCS,LLC, Lessee (Contmetor,Agent, Corporate Officer, etc.) of said owner or owners,and is duly aur:lorized to perform or have performed the said work and to make and file this application; that all statements contained in this app`ication are true to the best of;tis knowledge and belief, and that the work will be performed in the manner'set forth in the application filed therewith. Sworrj3o before me th' _ day of _20 I Nei -Cingular Wireless PCS,LLC By: Notary Public Signature of Applicr nt CHERYL A BLISS Kevin J. Russ,PMP Notary Public,State of NowYorlt A,,-.,-a Manager - Construction&I -igineering W.OIBLG056053•Suffolk County Certificate Filed in New York Cw* eomnassion Expires March 12.. � SOF SO�jy D MAR 2 9 2017 Town Hall Annex J�f Telephone(631)765-1802 I: 54375 Main Road cA (631)765-gg5 P.O.Box 1179 G roaer.dchertCatown.sfil� �+�+�+ Southold,NY 1197I-0959 �� fir' oI,YCOlJNt'1,� TOWN OF SOUTHOLD j. BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: - ,•e Date: 0231)--� Company Name:_ �ec47Y ' _ r , ;.. Name: , ; i License No.: Address: ? � C �d . �Cp /\-L\/ 1c7W i Phone No.: �- �0�1— �CvS— �S �. JOBSITE INFORMATION: (*Indicates required information) *Name: AT-4-( 1, — 10 ZS € *Address: ► O y�0—� N-��fii��s J.�,-,-ems � s'� ��� N� l l�� � Cross Street: i *Phone No.. `f'�—?� Pro c*, , Permit No.: Tax-Map District: 1000 Section: �3 Block: I Lot: ) *BRIEF DESCRIPTION OF WORK(Please Print Clearly) f (Please Circle Alf That Apply) *Is job ready for inspection: YENO. Rough In Final *Do-you need a Temp Certificate: YES/ NO Temp Information(if needed) *Service Size: 1 Phase 3Pha 150 200 300 350 400 Other *'New Service: Re-connect ndergroun Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION .82=Request for Enspecrion Form ' AN 37-17 57TH ST. Woodside NY, 11377 khasanddct11c.net 718-502-6262 Digital Construction Technology,LLC 718-255-6691 April 13,2017 To D Mike variety APR 1 3 2017 Inspector,Town of Southold Town Hall Annex,54375 Main Road,Southold NY 11971 BUILDINGDEPT. AT&T Site ID: LI-1025 TOWN OF SOUTHOLD Address: 1040-B Hortons Lane,Southold, NY 11971 BP # Subject: Regarding 03 Sets of Pole Foundation Drawing with NYS P.E.Stamp for LI-1025 Dear Sir, Attached please find the 03 sets of Pole foundation drawing with NYS P.E stamp for your review,approval& record. Please make your comments to accept it. Sincerely Mohammad Islam Project Manager Digital Construction Tech Inc Comments: Signature: TOWN OF SOUTHOLD COUNTY OF SUFFOLK: STATE OF NEW YORK --------------------------------------------------------------------------------------X In the Matter of the application of proposal of New Cingular Wireless PCS,LLC AFFIDAVIT OF For Approval to erect a public utility wireless telecommunications RADIO FREQUENCY unipole and install related equipment at the premises("Premises"): ENGINEER 1040-B Horton's Lane, Southold,New York District 1000 Section 63,Block 1,Lot 10 --------------------------------------------------------------------------------------X STATE OF NEW JERSEY ) ) SS.: COUNTY OF ) STEPHANE GUILLABERT,being duly sworn,deposes and says: 1. I am a radio frequency engineer for New Cingular Wireless PCS, LLC (hereinafter "AT&T"). As a radio frequency engineer, I am trained to identify service deficiencies in AT&T's wireless telecommunications network and to evaluate the ability of proposed antenna sites to remedy these service deficiencies. I am fully familiar with AT&T's wireless telecommunications network in Suffolk County. 2. I submit this affidavit in support of AT&T's application for approval to install a wireless telecommunications facility at the Premises. Pursuant to this application, AT&T requests approval to erect a telecommunications unipole, with antennas installed therein, and install its related equipment as depicted in the plans submitted herewith. 3. AT&T is considered a public utility for zoning purposes under the laws of the State of New York and is licensed by the Federal Communications Commission to serve the public within Suffolk County and throughout much of the United States. AT&T strives to provide reliable service throughout its licensed coverage area. 4. At present,there is a substantial service gap in AT&T's wireless network coverage in the vicinity of the proposed site. A service gap exists if the user of an AT&T mobile telephone cannot reliably transmit, receive or maintain a voice or data connection. The service gap in coverage that now exists in the vicinity of the proposed site prevents AT&T from providing reliable service in the area. This unreliability represents an inconvenience to users of AT&T's services and can have serious consequences during times of emergency or disaster. 5. In order to understand why the proposed antenna site is needed, it is necessary to understand how AT&T's system works from an engineering standpoint. AT&T's wireless telecommunications system is designed so that low powered base stations are strategically located at determined distances apart and at predetermined heights. Due to such factors as hills, valleys, trees, buildings, and other physical obstructions and due to the nature of radio waves, each coverage area or "cell" is irregularly shaped. With sufficient signal strength from each base station, the AT&T user can reliably transmit, receive or maintain voice or data connections. The sites are ordinarily engineered to cover a limited area so that an antenna facility will cover only the area surrounding it but will not interfere with other sites in the system. 6. AT&T has established design criteria so that its wireless network will provide reliable wireless service to its customers, whether those customers are on the street, in a vehicle, or in a building. Providing reliable service to AT&T's customers within vehicles and buildings is critical for AT&T to provide the quality of wireless service that customers demand and successfully compete with other wireless providers. 7. To meet customer demands and expectations, AT&T strives to provide both In-Vehicle (or In-Car) coverage and In-Building coverage. These coverage levels represent the minimum signal strength and reliability of service needed to transmit,receive or maintain a voice or data connection at the mobile handset as the environment changes. 8. AT&T has reliable In-Vehicle coverage when a customer can place or receive a call within a vehicle successfully across 95% of a site's coverage area. In-Vehicle coverage generally results in unreliable in-building coverage. Since the signal level is stronger closer to the antenna site than further away from the antenna site,there will be some coverage within buildings close to the site. 9. AT&T has reliable In-Building Residential coverage when an AT&T customer can place or receive a call while in a building that is three stories or less in height successfully across 95% of the site's coverage area. This type of coverage will typically provide reliable coverage over the majority of the cell coverage area; however in some areas, and specifically at the outer geographic boundaries of the cell site's coverage area, coverage will be restricted and will likely lead to customers dissatisfaction if customers try to place or receive a call inside a windowless room,cellars or emergency shelters. 10. AT&T has reliable In-Building Commercial coverage when an AT&T customer can place or receive a call while in a building that is greater than three stories in height successfully across 95% of the site's coverage area. In-Building Commercial coverage is targeted for urban residential centers and business districts with high-rise buildings, and suburban business centers. Coverage issues may still occur in hard to serve locations such as within elevators and parking structures. 11. To provide these levels of coverage, AT&T has scientifically determined the strength of the wireless signal ("signal strength") necessary to provide these levels of coverage. Because wireless signals are attenuated (i.e. degraded or partially blocked) by obstructions such as trees, automobile windows,automobile sheet metal,and building materials such as wood,brick and metal,a wireless signal must be of sufficient strength in the ambient environment (i.e. outside with no obstructions) to reliably penetrate into automobiles and buildings. 12. Wireless signal strength is measured on a logarithmic power scale referenced to 1 milli- watt of power. Signal strength levels less than 1 milli-watt being negative. The smaller the negative dBm number, the stronger the signal. For example, -75dBm is a stronger signal level than —85dBm. An ambient signal level of—95dBm would provide reliable On-Street coverage. AT&T's system requires an ambient signal level of—85dBm to provide reliable In-Vehicle coverage, and an ambient signal level of— 75dBm to provide reliable In-Building coverage. These signal level requirements provide the basis for AT&T's design criteria. 13. AT&T's design criteria for wireless facilities serving an area are based upon providing 95% reliable signal over a site's coverage area to ensure reliable service for customers. This standard reflects a business judgment that 100% reliability is an unrealistic goal at this time due to financial, technical and environmental constraints. A 95% level of reliability is consistent with the level of service provided by AT&T's competitors and is the standard in the industry. Providing service at this level allows AT&T to satisfy customers' demands and compete on an equal footing with competitors serving the market. 14. To achieve the 95% reliable design goal, AT&T conducts extensive analysis based upon AT&T's technology and the area served. 15. In order to eliminate the service deficiency in a particular area, AT&T performs signal propagation studies to determine the height and location of the needed cell site. Based on its studies, AT&T determined that an antenna facility would have to be established within a narrowly defined search area in order to remedy the service gap in question. In this case,we determined that the installation of the proposed facility will allow AT&T to provide reliable service in the vicinity of the Premises. 16. AT&T has determined that the proposed antenna centerline heights of 72' and 62' are the optimal heights to ensure that reliable service can be afforded to AT&T users in the vicinity of the Premises. The location and height of the antennas is determined by some or all of the following factors: availability of existing structures, willingness of property owners to enter into leases, drive test data, location of existing antenna sites in the area, topography in the surrounding area, land cover features in the area such as buildings and foliage, and the results provided by computer propagation software that enables radio frequency engineers to predict the anticipated signal propagation at a given height and location 17. In order to illustrate the effect that the proposed site would have on coverage in its vicinity, propagation maps have been prepared demonstrating the different coverage levels summarized above. The maps depict the areas presently enjoying reliable service in the vicinity, and the area to be served by the proposed site. As the maps indicate,the proposed facility is of vital importance to AT&T's efforts to provide reliable service to the area in question. Unless this application is granted, AT&T will be unable to provide reliable service in the vicinity of the Premises. 18. The antennas proposed will not interfere with radio or television service or public safety telecommunications in the surrounding area. 19. AT&T will comply with all FCC rules regarding human exposure to radio frequency energy. 20. AT&T will comply with all FCC rules regarding interference to other radio services. / alt STEPHANtjtUILLABERT �-•'� OTS �9����` Swo to before met day of 4. = � �Q® :Zo NOT P �I ®��i '•. �.•� `�� cAROUN9 WA BURTON W JERRY LM i TOWN OF SOUTHOLD COUNTY OF SUFFOLK : STATE OF NEW YORK In the Matter of the Application of New Cinguiar Wireless PCS, LLC AUTHORIZATION OF For Approval to construct a public utility wireless telecommunications OWNER facility at the prem;ses("Premises"): 1040-B Hortons Lane, Southold,NY District 1000 Section 63, Block 1, Lot 10 STATE OF NEW YORK ) SS.: COUNTY OF SUFFOLK } Y being duly sworn,deposes and says: I am the C� '&�1nTof YSl XXXII, LLC, owner in fee of the premises known as District 1000,Section 63,Block 1,Lot 10(the"Premises"hereafter),and do hereby authorize New Cingular Wireless PCS, LLC ("AT&T" hereafter), and its representatives to bring such applications for municipal approvals as maybe necessary for constructing or installing on the Premises such antennas,support structures, and related equir nent as AT&T may require for the establishment of its public utility wireless telecommunication facility. As such,I willfully cooperate with AT&T and its agents in obtaining any required Approvals, COMMONWEALTH OF PENNSYLVANIA NOTARIAL SEAL SUZANNE HOFFMAN Notary Public WAYNE TOWNSHIP,CHESTER COUNTY My Commission Expires Apr 10,2017 Sworn to bef,re me this ,! 1�/ day f ,2014 C TA Y PUBLI DECLARATION Or COVENANTS AND RLSTRICTIONS DIST. THIS DECLARATION mad% by PUDG£ CORP. , this 12TH DAY 1000 of December, 19.0, a domestic corporation, having its principal SECTION offices at 50000 Main Road, Southold, New York, 11971, hereinafter 063.00 referred to an the DECLARANT, as the owner of premises described BLOCK in Schedule "A" annexed hereto (hereinafter referred to as the (. PREMISES) desires to restrict the ust? and enjoyment of said LOTjfPREMISES and has for such purposes dotermineed to impose or, said PREMISES Covenants and Restrictions and uoas hereby declare that a 010.000 I said PREMISES shill be hold and shall be con dyed subject to the following covenants and restrictions 1. DECLARANT has made atpplication to the Suffolk County Department o1' Health Services (bereinabft• referred to as the DEPARTMENT) for a permit to construct approval of pians or approval of a sub-division or development on the PREMISES 2, WHEREAS, the applicant , is desirous of ZP constructingg a commercial building consisting of 1001 mini-storng!s facility , such facility I will he used for storage of goods only and will not contain any plumbing or heating, nor will the apace be used for any manufacturing. Additionally, the apace will not be utilized j by any employee excoPt for placement and 1 removal of stored geode. The total number of employees shall never exceed 3, Should the applicant desire to, ev*end its operation into the instrtoted apace, application shall be first ,made to the DEPARTMENT for approval under current criteria and any additional sanitary disposal facilities required shall be installed In accordance with approved i plana prl4+ in taxing occupancy of the 1� restricted apace- , The maximum permissable ` daily sewage ttischArge shall nevwr exceed +i 4133.9 gpd. 3. The DECLARANT, its isuccessors and/or assigns shall set forth timse covenants , agreaments f and declarations in any and all leases to occupaanta , tenants ,end/or lessees of the above described property and shall, by their terms, subjoAt same to the covenants and restrictions contained heroin, of the tF.CtARANT, its successors and/+)r assigns to so condition the leaves shall not Invalidate thenar automatic subjugation to the +covenants and restrictions, :l A ► I4, All of the covenants and re®triet;hns contained hereft, shall be construed to be in addition to and not in derogation or limitation upon any pr1o..visi43ne of local, state w and �+ federal laws, ordinances, ardor or regulations in effect at the time of execution of this agreomento or at the time such laws, ordinances and/or regulations may thereafter be revi.aed# axendmad' or promulgated. S . Thi% document is made 6ubject to the provisions Of 411 laws req'jired by law or by their provisions to be ir+noriorated herein and they are to be incn ..�,.�a'akec� herein and rude a part hareof, nese though fully set forth, 6. The aforementioned Restrictive Covend,ila Shall be enforcoabl* by the County of Suffolk, State j of New York, by injunc•tive relief or by any tt .either remedy in eqW ty or at law. The failure of said aegencie g or the County of Suffolk to enforce the sage shall not be deemed to affect t. a validity of this covenant nor to impose any liability whatsoever upon the County of Suffolk or any officer or employee thereof. I } 7. These covenants and restrictions shall run with the land:. ,and shall,, be binding upon the DECLARANT, its successors and aseigns, and uponall persons or entities claiming under thaw and may be termin4ted., refta od or amended only with they, writ.te4i consent of the DEPARTMENT. S. If any section, aub0k�ction, paragraph, clause,. phraDe or provision of these covenants and restrictions shall, by a Court of compsttnt urledi:c.tion r be ad-judged #.l.legal, unlawful, nvalid, or held. to be unconstitutional, the aam shall hot affect the validity of these toVanants u nt part as a Whole, or any her p or p r hereof other than the part so adi.udged: io be illsgaal, unlawful, invalid, or+ vn—Institutional- 9. Local Law M32•1980-The DECLARANT represents and warrants that he has not offered or givcn -'ny gratuity to any official, employee, or agent of Suffolk County, Pew York Stats , or of any Political party, with the purpose or intent of securing favorable treatment with respect to th ,Oeriormaheo of an agre+emMt, and that such 'per�►on his read and familiar with the provisions of Local Law 032-1900. achedule i Consant, attached and made a pht has f PUDZI(GORP EYt 2_ � PRESIDENT � t c ' P&341 I. STATL OF NEW YORK ) SSI t COUNTY Of NASiAU y ON THIS 17TH DAY OF DECEMBER, 1990, BEFORE ME PERSONALLY CAME, JAMES L. CRAY. SR. , TO ME XHOV;N, WHO BEING BY ASE DULY SWORN DID DEP)SE AND SAY THAT HE RESIDES AT NO 0 BRIDGE LANA;, ! CU'CHiju,UE, NEW 't�RK; THAT HE IS THE PRESIDENT OF PUDGE CORP-9 THE CORPORATION DESCRIBED IN ARD WHIICH EXECUTED THE FOREGOING INSTRUMENT; THAT HE KWUWS THE SEAQ. OF SAID CORPORATION; THAT THE i` SEAL AFFTXED TO SAID INSTRUMENT IS SUCH CORPORATE SEAL; THAT IT WA3 SO AFFIXED BY ORDER OF THE F,nNRD OF DTRCCTORS OF SAID i'.ORPORATION, AND THAT HE SIGNED HIS NAME THERETO BY LIKE ORDER. I� MM1N , i } I� 11 I' � S • 1 ,1 ft`2 t ' 1 1, "RC,HEDULE A"' ' DESCR=.TION OF f�ROP,_,,T.Y DECLARANT: PUDGE .CORF. H.D. REF. NO. OR NAME OF SUB-DIVISION C 1090.012 ALL that certainplot, piece or parcel of land, situate. -lying and being at Southold, Town of Southold, County of Suffolk and State of Now York, more pmticularly bounded and described as follows: BEGINNING at a concrete monument (set on the gas eQi°ly line of Hortons Lana where the some is in'torsected by the northerly line of land now or• 4'ormorly of Marton and from said point of beginnings RUNNING THEM .forth 11 degrees 47 minutes 40 seconds West , 351.93 feet to a concrete ms3nument and land now or formerly of Finkbeinarl RUNNING THENCE aloha land of Finkbeiner and land now or formerly of Witkowski North 72 de`ress 27 minutes 00 seconds East, 180.33 feet to a oancrete monument and THENCE North 70 degrees 09 minutes 00 se-condo East, 342.41 foot to a concrete munument and land now or formerly of Charnews•1 RUNNING THENCE along said land now or formerly of Charnews and land nor or formerly of Jennings, South 17 degrees 43 minutes 30 seconds East , 828.24 feet to a concrete monument and land now or formerly of the 'Long Island Railroads RUNNING THENCE along said last mentioned land South 70 degrees 30 minutes 30 seconds West, 403.88 fast to a points and land now or formerly of Hcrtonj RUNNING THENCE along land now or for- marly of Horton the following two (2) courant and distancest (1) North 19 degrees 22 minutes 40 ercot►ds West, 261.28 feet to M concrete monument and (2) South 78 degrees 12 minutes 20 seconds West, 148.84 fest to the concrete monument set at the ®int or plane of BEbtNNING and this easterly line of Kortons Lens. DIST. 1000 SECTION 063.00 BLOCK 01.00 LOT 010.000 i "SCHEDULE S" CONSENT OF MORTGAGEE/LIENOR IDECLARANTI PURGE CORP. H.D. REF. Nn, OR NAME OF SU$•DIVISIONt C10-90-017. In the matter of the application of PURGE, the undersigned, as holder of a mortgage or lion on premises described in Schedule "A" annexed hereto, hereby consents to covenants and restrictions on said premises and hereby subordinates its mortgage zr lion on the premises described in said SCHEDULE "A": C P ` AMK FMR SAVINGS BY I EDWARD F. Y VICE ?RESIDENT STATE OF NEW YORK COUNTY OF Mf AU �S5. ON THE DAY OF ' 19909 before me par®onally came, to me known, who, being by me duly sworn, d + depo6e andaythat he resides at S l•►���) { 1 t .s..� that he is the Vico ,I,� ,�..t • of APPLE BAN FOR SAVINGS, the banking corporation der-cribed in and which executed the foregoing f said at instrument; -tbcs_.a�b that It was ace -*ff i x�d- artivir -of #gra..cf std'• e °tn, and that he his name thetrdto by like order. / AMA VKM XM" PON A. .f Na. anew M eunaw o� te,1eM j �! ®?® • �''•. �. 1. ,.ON 7M �•1• :`•.� . I ' '!x' i . .r Q ,a' .,, , .''.,. .•ti,• , `+'4r .l,P(�'_YgJ3 Ab 114• ' r • ' '� •- .r• � moi, �' , i tp•,. • {a - ! ,•I', • Fl.. Q `�a ' '� !1 t, P' '�'R�`i it.,�, r,• '' .•1 v} .'21!?� • P.. tt y°. !.. .r� ��:, ;•.. ,P'f', r eh',:7; ,'J'" i '} •. �,a .y wt 14a, •.:iq l`i ' .�•! • •,t:; , `. , 1••,Q'�. +Lsy`•�1.1 ). �'•t•....•a,...� ..(I, ���r�.;t11 %. '.s': =i(,`�';cl•'�ti';r.;i••. ;kf��yF.ti';i•"''+ ••!+, `�'���{'i:d'��tP:'t`1::,• �" ` ` ! _ ai r_iuc'•`.tl',',••�'�,,if F'.� � .i,.�.' 1L�1w'__,��I{ F..t^.: i�F:V��•, • t its" 'Y �•'x tt',r r .,LL.�'�'.v:{Ss 1'. ____ =rl:dn�._+•S'-:yin •.:.'.' ..�:nAi&�INfA���'.:.» e:tt �µ�(,'L�'h.. �` i;j.%�',ry,,,.. • j L.aie.�rs+ "i.:rli:s,'ali•e?2,'u1397>BrFt:�.1r. A°.h=if•M��:Ei�i:t1�11��'iti`le.•.� .Mt 1 i DICZ&ATION at COVUAM am ARMICTION TMfI 1YdU •I NM=A M DIST. :000 SECTION THIS ORCL& IGN grade this�,.�? day of n,�r.;rMRr- �, Sgt 063.00by �.PUDE GRI' .-.... having Its principal place .... . ..�- - BLOCK at business at ., sUlhuab hereinagtes 01,00 referred to an the "otCLA ". LOT 010,0Q0 ,, 8 oRIAa, DRCLAMNT is the awft*r in toe siarple of rsal 'property located within a sole source aquifer 'that is par- Ott to IM ticularly environmrntaliy sensitive, which pCoporty is mote fully �,. described in schedule "A", annexed WOW NHRRaAS, application her bm*n lade to the, IUTTOLX COUNTY OIVARTNINT pt RIALTH GIRViCZS (IMMi) for th"T approval to ac- aosdance with applicable standarda, and wHZ IAS, the tUTIOLK COUNTY OIlAATHINT OF RRALTH sxgueRS has approved said map provida+l, haa.ves , that this 4 Declaration be recorded as against the said real property in the ., outtalk County Clerk' s Office and. the Declarations contained herein be fully complied with- HpAlo THIRIt®Ro, gICLA rrarrsntao declares, and repre- �� sent$ that the above-describ gad- p:'opsrty is held subject to the tollowinq covenants and vesl#iucienia•j�1 s IN 1111 1, WM111111!!11,��111 III I F, .aq it'll ®sCLARAST, its successors, a;nd/or ,assigns represent that XkAg S aware of the requirements sot forth in psticiea V11 end xtx of the sulfolj+ Couaety s®nitary Code which set standards and restrictions for storage and discharge Of tcw:: or haaardous materials in Suffolk County. r 3. should there be any thong* to the operation or use of the premises, the 0gCLAOlvMj its successors and/or assigns oust notify the Suffolk County Department of Health Services as hereinafter provided. 3. The sanitary waste flow for the premises shall not exceed the population density equivalent of 4133.9) gallons per day for the lot's area as detezoLned pursuant to Article 6 Of the Suffolk County sanitary Code. Should the sanitary waste flow from the lot exceed the population density squivaltnt for the lot' s area, a sewage treatment facility must be provided in ac- cordonce with the provisions ut Article ` of the suffolk County sanitary Code and all buildings on thsi lot must be connected to the sewage treatment facility. ' 1. sh®maid a sewage treatmmm•nt facility or sewer district be- cosme available to service the preemmiseis, DIC T, its successors and/or assigns hereby agreetsl to connect to and be ssrved by such facility 'at district within lis days and Oct any existing Vzivate waste disposal facilities shall be disconnected and sban- donsd according to standards of the ICONS. �. ®BCLAAANT# its sucuessors, and/or assigns, agree that upon written notification by $come to the respective tenant or occupant, said tenant or occupant shall, at lts own cost and *S- pens*, install a monitoring well or %nils as per sperifications i of the sCous, both upgzadisnt and doringradient in the groundwata6 Z flow, where# in such notification, the &CONN specifies the facts and circumstances under which it has .reason to believe that the groundwater under said praises is or will be threatened by a source of pollution from the said premises. DICLAPAUTp its suc- cessors and/or assigns shall install said monitoring well or wells in conformance with any reasonable requirements of the $CON$ at its own cost and expense. i. All fee owners, tenants or ,occupants of the subject premises shall., without notice, during normal working hours, provide access and entry to the subject premises, buildings and facilltiss to authorised and appropriate county inspectors or Of- ficials, subject to any governmental security regulations. 7. The owner, tenant or occupant ;hereby consent, on behalf of themselves, their successors and/or assigns to permLt the dCDN9 to enter upon the above-described property and clean up any spills of illegal toxic or hazardous discharges, and to assume the roasonable cost of such cleanup. whi-ch cost shall be entered AS a judgment upon notice against the iowner, occupant, tenant or lessee responsible for such spill or spills. This paragraph shall not apply to spills or toxic or hozardaus Materials which are not caused by or the fault of the dwnar, tenant, occupant or lessee, or any of their agents and/or employees. i. All notifications required to 'be given haxeunder to the SCONB shall be in writing and addressed to the Commissioner of Health Services and mailed or delivered to the iCDHB# 225 Rabro � Drive test, Hauppou47a, New York$ 1179i, or to such other desig- noted person or agency as may be required. 3 ` !. The OXCLARAMT, its succossa rs, and/or assigns shall sot forth those covenantsp agreements and declarations in any and all leases to occupants , teaaants and/or losses* of the above. described property and shall, by their terno subject ceases to the covenants and restrictions contained heroin. railurs of the DZCLApAUTP its successors And/or aarsigne to so condition tete losses shall not invalidate their automatic subju®ation to the covenants and restrictions. 10. All of the covenants and restrictions contained herein shall be construed to be in addition 'to and not in derogation or Hesitation upon any provisions of local, stats, ani :adoral laws, ordinances, and/or rogulations in effect at the time of execution of this agroement, or at the time such laws, ordinances, and/or regulations may thereafter be revised, amondad# or promulgated. it . The declarations not forth in the WHIMAS clauses con- tained heroin shall be doomed and construed to be promises , covenants, and restrictions as if 4;ully repeated and set forth herein. 11 . This document is pude subject to the provisions of all laws required by law or by their provisions to be incorporated heroin, and they are deemed to be lncorporated heroin and made a part hereof, as though fully sot forth. 13. If any section, subaoction, iWagrafah, clavas, phrase or provision of these covenants and restrictions shall, by a court of competent jurisdiction, be Adjudged Illegal , unlawful, In- valide, or held to be unconstitutional,, the same shall not affect the validity of th'se covenants and restrictions as a whole, or any other part of provision hereof other than the part so ad- lgdged to be illegal, unlaw#ul, invaliLd# or unconstitutional. 3 • 11193N349 14. These Roattictive Covenants shall be enforceable by the County of Suttolk, State of ftw Tark, by injunctive rel*if or by any other comedy in equity or at lair. The failure of said agencies or the County at Quffolk to enforce Nasse *hall not be dewed to affect the validity of this covenant nor to impose any liability whatsoever upon the County Of lottolle at any officer or employee thereof. 19. Any violation of these restrictions and covenants shall cause the violator, in addition to any► fins$, penaltiq$ 444/02 forfeitures prescribed by law, to pay for any and all reasonable legal fees and expenses incurred by the County of iuffolk in en- fracing the Covenants and Restrictions contained herein. ;S. These covenants and restrictions shall run with the land and shall be binding upon the DICLAVIANTo its successors and/or assigns, and upon all persons ox entitles claiming under thea and may be terminated, revoked or seendod by the owner of the promises only with the written consent of the Department. 1�. Local Law 112-1160 - The VICLAPANT represents and war- cants that he has not offered or given any gratuity to any official , employee, or agency of Suffolk County, Now fork State, ur of any political party, with the purpose or intent of scouring favorable treatment with respect to the awarding air amending of an agreement, or the making of any detaerminations with compact to the performance of an agretment, and that such person has read grid is familiar with the provisions of Local Law 133-1900. *.r schedule b consent, attached ft art hereof. SYi .8. AXES L. GRAY' 11t. , PRESIDENT G.Q. STATE OF NEW YORK ) ( COUNTY OF NASSAU ) SS., � ON THIS 12TH DAY OF DECEMBER, 19909 BEFORE ME CAME, JAMES L. GRAY, SR. , TO ME KNOWN, WHO, BEING BY ME 'DULY SWORN, DID DEPOSE AND SAY THAT HE RESIDES AT NO No BRIDGE LANE, CUTCHOGUE, NtW YORK( THAT HE IS THE PRESIDENT OF PUDGE CORP. , THE CORPORATION DESCRIBED IN AND WHICH EXECIITED THE FOREGOING INSTRUMENT, AND . THAT HE KNOWS Tti4 SEAL OF SAID CORPORATION$ AND THAT HE SIGNED HIS NAME THERE10 BY LIKE ORDER. 01 4� II C 1 I�1 s �. !SCHEDULE ;'1 DESCRIPTION OF PROPERTY DECLARANTt PURGE CORP. H.D. REF. N0. OR NAME OF SUB-DIV3;SION C 10-90-013 ALL that certain plot, piece or parcel of land, situate, lying and being at Southold, Town of Southold, County of Suffolk and Stats of New York, more partioulairly bounded and described as followst BEGINNING at a concrete monument set on the easterly line of Hortona Lane where the same is intersected by the northerly line of land now or formerly of }Lorton and from said point of beginning; RUNNING THENCE North 11 degrese 47 minutes 40 seconds West 351. 93 fest to a concrete monument and land now or for-aicly of Finkbeinerl RUNNING THENCE along land of Finkbeiner anti land now or formerly of Witkowski North 72 degrees 27 minutes 00 seconds East , 180.33 fest to it concrete monument and THENCE North 70 dsgross 09 minutes 00 seconds East, 342.41 teat to a concrete munument and land now or formerly of Charnewa ; RUNNING THENCE along said land now or formerly of Chnrnsws and land nor or formerly of Jennings,, South 17 degrees 43 minutes 30 seconds East, 926.24 fest to a concrete monument and land now or formerly of the laongR Island Railroad; RUNNING THENCE along said lasL mentioned land South 70 degrees 30, minutes 30 seconds West, 403,116 feet to a point; and land now or formerly of Horton; RUNNING THENCE along land now or for- merly of Horton the following two (2) courses and distances; (1) North 19 degrees 22 minutes +00 seconds West, 261.23 fest to a concrete monument an* (2) gouty 7e doSress 12 minutes 20 seconds West, 148.64 feet to the concrete monument set at the poin°t ' or place of BEGINNING and the easterly line of Hortons ns. DIST. 1000 SECTION 063.00 ROCK 01.00 LOT 010.000 �f F js 7 0 7M WAWA "SCNEDU X Btt CON0.2�SENT O00000WF MORTGP,dMUG IENMOR DECLARANT: PURGE CORP, H.D. REI'. $i0. OR i NAME OF SUB-DIVISION: CIO-90-012 , In the matter of the application of PURGE, the undersigned, as holder of a mortgage or lien an premises described in e Schedule "A" annexed hereto, hereby consents to covenants and restrictions on said premises aliq }'ereby subordinates its mortgage or lion on the promises described in said SCHEDULE "A". ,LE K I"OR SAVINGS a SYl ' 41 " ev s 841* STATE OF NEW 'YORK } COUNTY OF AASSAU )SS t ON THv .L AY OFvvJ.. . , 1900, befdr* Baa po:Osonally cme, to toe ka�own9 who, baing by'� dulysworn, dig o a nd say that he resides: at .p t 1 that be is the vt'( Pt'4 V...s of.,,.A,. PLE 8A FOR SAVINGSt the banking, dorroretion described in and which executed the foregoing instrument; t M . °Linn, and that hs siSned his name thereto by like i ardor. l , K MM A. 1ALWA 1 *'"a Q11toh�4AN .��{. r rn :ftt`4!;♦.}r�.R..•<yn• �` •.I.„1}m... •ii'r' i y� �� ��- _,.. f f.��, ..ty i � j I;y�tlSu.`.iA�;•• . >'•fti+h. .d•�.�'. ♦r"•;,t t,' '' ,l r ,.r "•r. ^r r .„,r.l,ljyl.sli::�'i'h,. M1' 'r�h"�•�>Y° - _ � '!. ��lir t'�• �-, a >^fir ,• , „�,r, , < ., ,,,.4' ^� i�7••!� :,' rt' ,! ',. r • •i�'`4�•>^•lYr•:. `r',•r •'J_,'r r•. '. ,' • Vii. " 'i�, .,'+i'r , ' :.'"l.i .. - ,• , (` OL. :r _ u REFERENCE COPY This is not an official FCC license.It is a record of public information contained in the FCC's licensing database on the date that this reference copy was generated.In cases.where FCC rules require the presentation,posting,or display of an FCC license,this document may not be used in place of an official FCC,licen'se. omm ederal`F Communications Commission o ,'`• G Aly`,:r:.,fi.:..}-,.> Wireless Telecommunications Bureau so RADIO STATION AUTHORIZATION LICENSEE: NEW;,CING ARI.WLRELESS PCS LLC Call Sign File Number d'f:x.91'.•fa J'✓'1�.4 KNKA' ATTN:REGINALD YOUI�G!§4.00D� Radio Service NEW CINGULAR WIRELES$,PCS;I:iLC CL-Cellular 2200 N.GREENVILLE AVE;.1, !'%;,;� RICHARDSON,TX 75082 �` �? `` i Market Numer Channel Block CMA001 A t Sub-Market Designator � t:; FCC Registration Number(FRN): 000329,1�92,�; .,_,;� 0 Market Name New York,NY-NJ/Nassau-Suffolk Y Grant Date Effective Date ` -tratiob Date Five Yr Build-Out Date Print Date 08-16-2005 11-24-2012 - 10-0122015 Site Information: Location Latitude Longitude Gro0J Elevation Structure Hgt to Tip Antenna Structure \ (metersg)),, Registration No. ,� 'V (meters)�' 10 40-36-05.0 N 074-06-30.3 W 116.1 Address: 140 Merrick Avenue City: STATEN ISLAND County:RICHMOND State:NY i""4onstpbDeadline: Antenna: 1 Azimuth(from true north) 0 45 90 1 511 180 225 270 315 Antenna Height AAT(meters) 139.900 143.100 140.300 146.500 146'000';x`..!4128.100 140.700 137.000 Transmitting ERP(watts) 278.700 129.600 12.300 1.000 �,-'Qt200 0:400 11.200 135.700 Antenna:2 Azimuth from true north 0 45 90 135 '-1;480 2" 270 315 ( ) Antenna Height AAT(meters) 146.000 149.200 146.400 152.600 fl!5'2;1.00 134.200 146.800 143.100 TransmittingERP watts 22�. 6b' (watts) 6.000 83.600 284.900 183.300 22:400 115400,? 0.200 0.200 tri- 7;1•.,� Antenna:3 Azimuth(from true north) 0 45 90 135 180 it '225''"'•;°, 270 315 . Antenna Height AAT(meters) 146.000 149,200 146.400 152.600 152.10 .:tj3j,,:2W 146.800 143.100 Transmitting ERP(watts) 0.300 0.100 3.400 48.000 265.500 236.:500 .,x39.000 2.400 Conditions: Pursuant to§309(h)of the Communications Act of 1934,as amended,47 U.S.C. §309(h),this license is subject>to t_hezf,3 following conditions: This license shall not vest in the licensee any right to operate the statio 'nor aryfright iir,.tlig,•iise':of the frequencies designated in the license beyond the term thereof nor in any other manner than authorized hei 'ier the license not the right granted thereunder shall be assigned or otherwise transferred in violation,of the Communications Act of 1934,as amended. See 47 U.S.C. §310(d). This license is subject in terms to the right of use.or control conferred by§706 of the Communications Act of 1934,as amended. See 47 U.S.C.§606. FCC 601-C Page I,of 20 August 1607 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA3jff,',:.,;,N File Number: Print Date: Location Longitude Ground Elevation Structure Hgt to Tip Antenna Structure :"} �} "=f: •:r (meters) (meters) Registration No. 13 071-58-32.2 W 55.5 54.3 Address:MOU1 A`�UK$TATE POINT$OULEVARD City:East Hampton tt.County:;$UFFOLK State:NY Construction Deadline: Antenna: 1 Azimuthb'( om�`lr4ute=north`J v0•; 45 90 135 180 225 270 315 Antenna Height AAT(meters)�s. >Y : 91;'500 87.900 91.500 91.500 91.500 90.800 90.600 91.500 Transmitting ERP(watts) Mrt`r` ' "146.300 65.300 7.700 0.500 0.200 0.600 9.200 68.400 Antenna:2 Azimuth(from true north`;;;'0,,-,, 45 90 135 180 225 270 315 frM;.::,..f.FS Antenna meters AAT Height g (meters) ; 91,50,0 87.900 91.500 91.500 91.500 90.800. 90.600 91.500 Transmitting ERP watts " 2;500 32.500 162.900 208.200 57.300 5.100 0.200 0.100 :.:; . Antenna:3 Azimuth(from true nortfi) Ots45 99 135 1$Q 225 270 315 Antenna Height AAT(meters) �91r500 '7'.'900 91.500 91.500 91.500 90.800 90.600 91.500 Transmitting ERP(watts) 2 300 �5620''4': . 0.200 6.000 62.900 208.200, 159.200 27.700 Location Latitude Longitude .., �':�`mGround Elevation Structure Hgt to Tip Antenna Structure meters) (meters) Registration No. ..0 28 41-15-30.5 N 073-32-04.9 W 230:7; . 48.5 Address:Route 35 and Route 123 ` City: South Salem County:WESTCHESTER State• Y: Construction Deadline: Antenna: 1 Azimuth(from true north) 0 45 9Q;;`'-+" ' '#135 180 225 270 315 f +.Y Antenna Height AAT(meters) 47.600 85.80008 7009.200 143.900 113.000 153.200 116.400 Transmitting ERP(watts) 61.600 9.400 011A =s 0.1,,0.,0, 0.100 0.200 7.200 45.000 Antenna:2 Azimuth(from true north) 0 45 90 f135' `: 180 225 270 315 Antenna Height AAT(meters) 47.600 85.800 108.700,-:)t! 143900 113.000 153.200 116.400 Transmitting ERP(watts) 0.100 0.400 7.9003b800" 30.700 3.300 0.300 0.100 Antenna:3 Azimuth(from true north) 0 45 90 135 180,,,-, 225 270 315 Antenna Height AAT(meters) 47.600 85.800 108.700 139.204 g,91A3900� `113.000 153.200 116.400 Transmitting ERP(watts) 0.700 0.100 0.100 0.400 "1'2.100 64:500 69.700 9.000 P. ;< �i1i.Y Y*v t�T FCC 601-C Page 2 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC , Call Sign:KNKA31:0�!�;.,��a File Number: Print Date: Location Latifii"de. rA ;; Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters) Registration No. 31 40-24-4,6':4 `'4'" 074-36-05.3 W 95.7 86.6 1056213 Address:45 OL;.'.GEORGETOWN RD. 7.7 City:Rocky Hill /County:°Sp`MERSET State:NJ .Construction Deadline: Antenna: 1 Azimutht((from litre north), ;0. 45 90 135 180 225 270 315 Antenna Height AAT(m'eters),,.;, ;,,,85;500 78.900 72.700 78.400 83.400 60.300 48.900 69.600 Transmittiug ERP(watts) , 116.900 168.700 33.900 1.700 0.100 0.100 0.400 10.700 Antenna:2 Azimuth(from true norGl ''a,M.;Q f 45 90 135 180 225 270 315 Antenna Height AAT(meters) ;;L `` f98 fiQ0 92.000 85.900 91.500 96,500 73.400 62.000 82.700 Transmitting ERP(Watts) .t': O IdO 1.600 39.000 212.300 157.700 17.800 0.500 0.100 Antenna:3 Azimuthfrom true north 0, ;';a a,;;=4 ( � 45 90 135 180 225 270 315 Antenna Height AAT(meters) �$5;5008900 72.700 78.400 83.400 60.300 48.900 69.600 Transmitting ERP(watts) 0.400 ";0a00, 0.100 0.100 0.300 5.300 13.800 5.400 Location Latitude Longitude ° ;.., x,,,Ground Elevation Structure Hgt to Tip Antenna Structure (meters) Registration No. ; 1 (me;�ers) 53 ;�1, 40-44-59.2 N 072-57-06.9 W r-;�;6"I�=�<L'�`�,. 38.1 Address:40 South Country Road City:Village of Bellport County: SUFFOLK State:lli 1111 Construction Deadline:04-05-2012 .�✓'..r 4`l"i .*r•7 Antenna: 1 Azimuth(from true north) 0 45 9,q; 35 180 225 270 315 Antenna Height AAT(meters) 30.000 30.100 3;,000 443.300 43.200 43.100 36.700 30.000 Transmitting ERP(watts) 228.300 279.800 8 ;5Q0; 10,,.600 0.700 0.600 3.400 46.100 wwlm.h. � , . a.� :ijhl.-.1 Antenna:2 Azimuth(from true north) 0 45 90 ;135 `' 180 225 270 : 315 Antenna Height AAT(meters) 30.000 30.100 43.000 ' X43:;OO;;f,,, 43.200 43.100 36.700 30A'00 Transmitting ERP(watts) 3.400 46.100 228.300 �ti279.800 85,500 10.600 0.700 0.600 Antenna:3 Azimuth(from true north) 0 45 90 135 180,. ,,r„'.: 225 270 315 Antenna Height AAT(meters) 30.000 30.100 43.000 43.300 AT 200" -43._100 36.700 30.000 Transmitting ERP(watts) 22.700 1.500 1.000 1.600 (21.600 151,,400 305.600 148.000 ' W � FCC 601-C Page 3 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC r l Call Sign:KNKA3,�1.0;:;=e ,, File Number: Print Date: Location Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters) Registration No. 54 41-01-4¢ 072-29-50.2 W 17.7 30.5 Address:21855- J' n 0ad:48 City:Cutchogue,>Cobnty°SUFFOLK State:NY Construction Deadline:04-05-2012 Antenna: 1 Azimuth'(from'Uru'imorth).,-O, 45 90 135 180 225 270 315 Antenna Height AAT(neters) � 33.100 37.300 30.700 38.000 30.000 38.800 39.000 Transmitting ERP(watts) 61.000 41.500 7.400 1.100 0.300 0.500 9.200 40.500 yi to Antenna:2 Azimuth(from true north)" '0'; 45 9Q 135 180 225 270 315 Antenna Height AAT(meters) , X39 0 ,0 33.100 37.300 30.700 38.000 30.000 38.800 39.000 Transmitting ERP(watts) ,;_r t°67p0 66.200 217.800 243.300 104.400 15.500 2.000 0.800 Antenna:3 Azimuth(from true north) `0 ;y',',;'•'a;,, =45 90 135 180 225 270 315 . Antenna Height AAT(meters) 1,q;000 3'3:100 37.300 30.700 38.000 30.000 38.800 39.000 Transmitting ERP(watts) 9.100 ;1t,3'0O°:• 0.900 17.200 105.600 245.500 209.800 58.200 r,n ground Elevation Structure Hgt to Tip Antenna Structure Location Latitude Longitude sir'.!.,.,• "'" (meters) Registration No. 55 40-44-55.8 N 073-02-11.9 W 7:6°'fi4 '},a 19.2 Address:Blue Point Avenue ; City:Blue Point County: SUFFOLK State:NYC�nsfi°uct�on Deadline:04-05-2012 Antenna: 1 Azimuth(from true north) 0 45 90.1?jk-T;,°W5 180 225 270 315 Antenna Height AAT(meters) 30.000 30.000 0: 00 x;3'0.000 30.000 30.000 30.000 30.000 Transmitting ERP(watts) 164.500 285.200 54'iOQr 1.600 0.100 0.100 0.700. 14.600 Antenna:2 Azimuth(from true north) 0 45 90j3S �,,,', 180 225 270 315 Antenna Height AAT(meters) 30.000 30.000 30.000 £'`W30 Qp;f`; 30.000 30.000 30.000 30.000 Transmitting ERP(watts) 0:100 1.600 36.700 25x4 800 202.400 22.100 0.200 0.100 Antenna:3 Azimuth(from true north) 0 45 90 135 180 sr.,-r, 225. 270 315 Antenna Height AAT meters 30.000 30.000 30.000 30.000 ' �� g, (meters) 000 30000 30.000 30.000 Transmitting ERP(watts) 7.200 0.100 0.200 0.300 5:000. R2:300 312.800 113.600 i� #t ,�rur>�. k FCC 601-C Page 4 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA31,0: �;:, File Number: Print Date: Location-X'ititud6e , \ Longitude Ground Elevation Structure Hgt to Tip Antenna Structure r:. meters (meters) Registration No. 56 40-38-04:0 N''^�.,-y 073-19-57.0 W 3.0 38.1 1237189 Address:OC N;PARKWAY City:BABYLONk? CQunty:'"SUFFOLK State:NY Construction Deadline:04-05-2012 tf Antenna: 1 Azimuth(from tcd&,,Aorth),-0., 45 90 135 180 225 270 315 Antenna Height AAT'(md"ters)sr ;k 30000 31.300 31.800 32.000 32.000 32.000 32.000 30.000 Transmitting ERP(watts) ;r 00 103.600 12.200 0.800 0.300 1.000 14.600 108.400 Antenna:2 Azimuth(from true 45 90 135 180 225 270 315 Antenna Height AAT(meters)r. �a X30 400 31.300 31.800 32.000 32.000 32.000 32.000 30.000 Transmitting ERP(watts) V ` 8x200 76.600 220.800 140.100 21.200 1.700 0.300 0.500 Antenna:3 Azimuthfrom true nort�i ( )""Q,,.r"r;.,t€;::>"='.a',4.5 90 135 180 225 270 315 C ".;, Antenna Height AAT(meters) 5, 000 31.300 31.800 32.000 32.000 32.000 32.000 30.000 ..,^ n Transmitting ERP(watts) 3.900 ;4t`Q.;IOQ 0.100 3.400 41.400 180.900 191.900 46.000 'Ob-, Location Latitude Longitude '«4;a`Ground Elevation Structure Hgt to Tip Antenna Structure "4 uM eters) (meters) Registration No. 57 41-26-18.9 N 073-46-37.6 W ` 5.6U 33.2 ° . Address:CALIFORNIA HILL ROAD(WAWAYA�jp1 RO ) City: CARMEL County:PUTNAM State:NY Construction Deadline: 04-05-2012 Antenna: 1 Azimuth from true north �i 1, '` a ':" ( ) 0 45 90 - • 135 180 225 270 315 Antenna Height AAT(meters) 198.300. 139.700 94.700 21`0.300 190.500 218.900 147.400 153.600 Transmitting ERP(watts) 88.100 113.600 24 '00'n, 2.7.0.0 0.700 0.300 3.100 24.300 Antenna:2 Azimuth(from true north) 0 45 90 :135 :'. 180 225 270 315 Antenna Height AAT(meters) 198300 139.700 194.700`';�y2130Q: 190.500 218.900 147.400 153.600 Transmitting ERP(watts) 0.500 6.200 43.200 108 4(0 86.100 11.400 .1.200 0.300 Antenna:3 Azimuth(from true north) 0 45 90 135 180225 270 315 Antenna Height AAT(meters) 198.300 139.700 194.700 210.300 19;500''''218.900 147.400 153.600 .:;.,a g Transmitting ERP(watts) 9.700 1.600 0.100 2.200 ��:,26.600 QA00 242.800 103.600 6 , FCC 601-C Page 5 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA.3,1•0�f,, File Number: Print Date: LocationLatitudef,- ;i } Longitude Ground Elevation Structure Hgt to Tip Antenna Structure • ,;;-'.r.>-;;! (meters) (meters) Registration No. 58 41-28-20IE ISH'`' 073-49-00.2 W 365.8 33.8 Address:CLANCE FAIINESTOCK STATE PARK ROUTE 301 .;Y ., City:COLD SPun'`..r PUTNAM State:NY Construction Deadline:04-05-2012 7 Antenna: 1 Azimuthfromueriorth ) 0� 45 90 135 180 225 270 315 Antenna Hei ht AAT meters "" 271U''600 85.500 161.400 159.600 161.000 182.400 200.000 254.700 Transmitting ERP(wafts),g r °'`"`x121.700 51.900 4.800 0.800 0.100 1.100 13.300 65.300 Antenna:2 Azimuth(from nu°'e noh) ; 0;"r, 45 90 135 180 225, 270 315 pPt:.,m ,•r Antenna Height AAT(meters)I' r''V 85.500 161.400 159.600 161.000 182.400 200.000 254.700 Transmitting ERP(watts) X24.300 88.100 113.600 24.300 2.700 0.700 0.300 Antenna:3 Azimuth(from true nort )`A 0 4a`''�45 90 135 180 225 270 315 Antenna Height AAT(meters) 270:600 $5.500 161.400 159.600 161.000 182.400 200.000 254.700 Transmitting ERP(watts) 2.400x070'0''.,, 0.900 12.500 86.100 216.400 171.900 22.700 r , Location Latitude Longitude ti' AWg,,Ground Elevation Structure Hrtto Tip Antenna Structure (miters) (meters) Registration No. 59 40-48-03.0 N 074-48-24.9 W �s3 z9:W1��, 37.2 Address:204 Schooley Mountain Road ' City:Long Valley County:MORRIS State:NJ Coit'"ruction Deadline:04-05-2012 Antenna: 1 Azimuth(from true north) 0 45 qw, { x 13,5 180 225 270 315 Antenna Height AAT(meters) 124.300 30.000 124200 =x;82.100 156.500 114.400 155.800 130.300 Transmitting ERP(watts) 172.300 16.200 O.Cpb y;'. 0.30.0 0.500 0.300• 8.700 143.400 t.t•. Antenna:2 Azimuth(from true north) 0 45 90 f;, `"�` "f 180 225 270• 315 ,. .:. Antenna Height AAT(meters) 124.300 30.000 124.200'%1\18,.100f' 156.500 114.400 155.800 130.300 Transmitting ERP(watts) 0.200 5.600 119.400 )fid 'A0 22.800 0.900 0.300 0.500 Antenna:3 Azimuth(from true north) 0 45 90 135 180,x, 225 270 315 Antenna Height AAT(meters) 124.300 30.000 124.200 182.100 156:500i:A,11 1;4.400 155.800 130.300 Transmitting ERP(watts) 0.200 0.500 0.300 1.000 x.';,`4 .500 232:000 77.200 3.600 jr)!7 r FCC 601-C Page 6 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign: File Number: Print Date: Location rL'ahtu`de: ;'. Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters) Registration No. 40-49-27iN"two'" 074-46-28.6 W 312,7 53.6 Address:Nocktoty i Road,-, City:Long Valley GQuiity:,MORRIS State:NJ Construction Deadline:04-05-2012 Antenna: 1 Azimuth(from e"north), 0 45 90 135 180 225 270 315 Antenna Height AAT`(iieters) 1)6'1x',V'67 300 30.000 96.700 161.500 121.500 72.200 126.300 131.900 Transmitting ERP(watts) V164.500 285.200 54.500 1.600 0.100 0.100 0.700 14.600 Antenna:2 Azimuth(from true no�tli);::,4.,0 �. 45 90 135 180 . 225 276 315 Antenna Height AAT(meters) ;'.°:r' ;;;,67.0.0 30.000 96.700 161.500 121.500 72.200 126.300 131,900 Transmitting ERP(watts) 1.600 36.700 254.800 202.400 22.100 0.200 0.100 Antenna:3 Azimuth(from true nort�i)' O P,, '':. 45 90 135 186 225 270 315 Antenna Height AAT(meters) '67:300 §0'.000 96.700 161.500 121.500 72.200 126.300 131.900 Transmitting ERP(watts) 7.200 'U:.10 ;, 0.200 0.300 5.000 82.300 312.800 113.600 Location Latitude Lon tude 4°`1'a:. '°`'Ground Elevation Structure Hgt to Tip Antenna Structure' k meters) (meters) 61Registration No. .. 40- 42.132-45.7 N 074-44-21.8 W5��9 ,,.b Address:Route 202&Evergreen Drive } rd.•,3.) City:Branchburg County: SOMERSET State:NJ@onst'ruction Deadline:04-05-2012NJ , Antenna: 1 Azimuth(from true north) 0 45i Q.Q= _ ""^��i'135 180 225 270 315. Antenna Height AAT(meters) 30.700 30.000 64:900 A55800 30.000 32.600 30.000 30.000 Transmitting ERP(watts) 312.800 77.200 3`1601`6 0.200 0.700 0.400 2.000 72.100 Antenna:2 Azimuth(from true north) 0 45 90 ' \ 180 225 270 315 Antenna Height AAT(meters) 30.700 30.000 64.900 (i",�ii,135 x55: " > 30.000 32.600 30.000 30.000 00, Transmitting ERP(watts) 11.200 184.800 222.000 x"20 800" 0.700 0.400 0.700 0.400 Antenna:3 Azimuth(from true north) 0 45 90 135 180,.,,-;.3;r,Y,225 270 315 Antenna Height AAT(meters) 30.700 30.000 64.900 55.800 �6,30',000-, 'N32:600 30.000 30.000 Transmitting ERP(watts) 0.700 0.400 0.700 0.400 117,,�<1�.2008,4:800 222.000 20.800 F A:^, .L FCC 601-C Page 7 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA310;; File Number: Print Date: LocationwLa`titu'de� Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters) Registration No. 62 40-35-, 074-08-03.5 W 83.2 44.2 Address:460 BLLE AVE„ City: Staten Island C`ouinty;R OND State:NY Construction Deadline:04-05-2012 Antenna: 1 Azimuth .from truea�orth:w 0� � 45 90 135 180 225 270 315 Antenna Height AAT meters) ,. ',,+,;.98300 85,000 101.400 103.000 101.000 88.400 95.300 92.900 Transmittin ERP watts ar'w;,'" `°° g' (watts) ..,-,.,. ' '312.800 103.600 6.000 0.100 0.200 0.300 5.800 92.300 Antenna:2 Azimuth(from true north)'.0; �y 45 90 135 180 225 270 315 Antenna Height AAT(meters) .' °'.-'98?300 85.000 101.400 103.000 101.000 88.400 95,300 92.900 Transmitting ERP(watts) *;r.: Qr800 ,16.400 175.900 278.700 48.400 1.300 0.100 0.100 Antenna:3 Azimuth(from true north)° O R;,,; ,:45 90 135 180 225 270 315 Antenna Height AAT(meters) 8'x300 85:000 101.400 103.000 101.000 88.400 95.300 92.900 Transmitting ERP(watts) 0.200 >0 1'OQ', 0.100 1.800 41.200 266.800 188.500 19.300 Location Latitude Longitude �";; , v`'£Ground Elevation Structure Hgt to Tip Antenna Structure meters) (meters) Registration No. 63 ;. 40-26-06.5 N 074-40-55.5 W � 47 5' "'; 42.7 Address:42 Concord Lane City:MONTGOMERY TOWNSHIP County: SOMERET; r%'State:NJ Construction Deadline:04-05-2012 ,.T" from true north 0 45 Antenna: 1 Azimuth( ) j 5 180 225 270 315 9Q,:;,,� Antenna Height AAT(meters) 49.700 57.90092QQ r.S •100 42.400 31.600 30.000 30.000 Transmitting ERP(watts) 217.800 243.300 1GO 15.500 2.000 0.800 6.700 66.200 Antenna:2 Azimuth(from true north) 0 45 . 90 ;. �° `'" 13 180 225 270 315 Antenna Height AAT(meters) 49.700 57.900 49.200 P55 190,1 i 42.400 31.600 30.000 30.000 Transmitting ERP(watts) 0.900 17.200 105.600' 245500✓ 209.800 58.200 9.100 1.300 Antenna: 3 Azimuth(from true north) 0 45 90 135 180 .:, ,>;;e 225 270 315 Antenna Height AAT(meters) 49.700 57.900 49.200 55.100 X42 400�` 31,:600 30.000 30.000 Transmitting ERP(watts) 29.600 4.400 1.300 1.800 :y 136.500 1'6.1 400 242.800 165.200 .YJ FCC 601-C Page 8 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign: l File Number: Print Date: Location,,L"atitud'e, _-': Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters) Registration No. 64 �,z.,..a•. .�. 40-58-3,6 N- ' 074-35-47.9 W 336.2 28.7 Address:HIGH ?XFiW TERRACE EXTENSION City:JEFFERSON'Tgw"mSHIPy� County:MORRIS State:NJ Construction Deadline:04-05-2012 Antenna: 1 Azimuth s(fiom`t�rizetio;th),, 045 90 135 180 225 270 315 Antenna Height AATmeters) �;y s;: ;88 600 63.800 75.100 151.600 100.900 65.300 105.800 118.100 Transmitting ERP(watts) 226.600 76.800 6.700 0.200 0.100 0.400 21.600 149.700 Antenna:2 Azimuth ( ' 40;x'` 45 90 135 180 225 270 315 from true nortl `.; �a Antenna Height AAT(meters) i;188 600 63.800 75.100 151.600 100.900 65.300 105.800 118.100 TransmittingERP watts "-b_,, (wafts) ,;,`0,Jy,O'0 ,,,0.400 21.600 149.700 226.600 76.800 6.700 0,200 Antenna:3 Azimuth(from true north) 0 tt ..`•'d',4S 90 135 180 225 270 315 Antenna Height AAT(meters) $$::500 6 `.800 75.100 ,^ 151.600 100.900 65.300 105.800 118.100. Transmitting ERP(watts) 6.700 0 200; , 0.100 0.400 21.600 149.700 226.600 76.800 ' Location Latitude Longitude �;;,�•,.,.� (Yr;{,Ground Elevation Structure Hgt to Tip Antenna Structure (meters) Registration No. 65 40-24-05.9 N 074-38-50.2 W A6i3 33.5 Address:YOUNG DRIVE-ROCKY HILL WATEIf' ANK " City:ROCKY HILL County: SOMERSET State:N .. ; D04-OS-2012 , Antenna: 1 Azimuth(from true north) 0 45QV s35 180 225- 270 315 Antenna Height AAT(meters) 50.200 47.300p`t3004$.1Q0. 46.600 30.000 30.000 ' 30.000 Transmitting ERP(watts) 62.500 5.600 0.2Ob i, O IAO.O 2.100 28.500 160.800 216.400 mow.,, ,�=r• ,;;•,;...�, Antenna:2 Azimuth(from true north) 0 45 90 '135 '" 180 225 2`10 315 �N.v,, � �w"r, Antenna Height AAT(meters) 50.200 47.300 30.0001.;48` '0.0'r'-' 46.600 30.000 30.000 30.000 Transmitting ERP(watts) 59.600 211.400 168.009 ;31300`` 2.200 0.100 0.200 5.400 Antenna:3 Azimuth(from true north) 0 45 90 135 180, in,,,.".225 270 315 Antenna Height AAT(meters) 50,200 47.300 30.000 48.100 4'6:600``-'s'`3,�0�000 30.000 30.000 Transmitting ERP(watts) 0.100 0.600 13.400 106.000 {;;242.800 x' .200 14.600 .0.800 FCC 601-C Page 9 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA3.k0,:-"i`,, File Number: Print Date: ,5 Location �;a{ltude; yr„;;, Longitude Ground Elevation Structure Hgt to Tip Antenna Structure meters meters r.•;,.:.. (meters) (meters) Registration No. 66 l� 40-54-, O;I�T'p `' 074-44-38.5 W 250.2 46.3 �r•'d' Address:207 WAT RLQO VALLEY ROAD City:MOUNT O-JI V :,;, oupy:MORRIS State:NJ Construction Deadline:04-05-2012 Antenna: 1 Azimuth(firoin trueriorth), ;;0, 45 90 135 180 225 270 315 Antenna Height AAT(teeters) rdF u;;; 64 200 30.000 30.000 30.000 30.000 49.800 42,700 61.100 Transmitting3p5.600 140.000 18.400 1.000 0.200 0.700 16.800 133.400 Antenna:2 Azimuth(from true nortl ;;.p;,,;; 45 90 135 180 225 270 315 Antenna Height AAT(meters) 2.s'•.` y`c'.(4y2 ,0 30.000 30.000 30.00030. 00 49.800 42.700 61.100 Transmitting ERP(watts) 0.200 0.300 6.80Q 75.000 266.200 211.400 39.400 Antenna:3 Azimuth(from true north)" 90 135 180 2.25. 270 315 Antenna Height AAT(meters)' X64:`200 30'.}000 30.000 30.000 30.000 49.800 42.700 61.100 Transmitting ERP(watts) 2.700 elgj 900,. 202.400 272.400 78.700 7.000 0.200 . 0.100 1 Location Latitude Longitudevyr. ?- Ground Elevation Structure Hgt to Tip Antenna Structure jne ers) (meters) Registration No. 67 41-10-53.6 N 074-23-16.2 W 1713§6 4'"%�.. „•�;.-.. 41.1 Address:776 Warwick Turnpike "'`^ t`" City:Hewitt County:PASSAIC State:NJ Construc6oii headline:04-05-2012 Antenna: 1 Azimuth(from true north) 0 459U ''`;135 180 225 270 315 �:>:`Is Antenna Height AAT(meters) 214.700 96.900 3,;8,.40042,39.400 91.200 39.800 116.800 176.000 Transmitting ERP(watts) 248.400 61.500 2.600';'<',-A 0,2P0 0.500 0.300' 1.600 57.200 du}>4 Antenna:2 Azimuth(from true north) 0 45 90f 135 #• 180 225 270 315 Antenna Height AAT(meters) 214.700 96.900 138.400-,,�23 91.200 91.200 39:800 116.800 176.000 Transmitting ERP(watts) 0.500 0.300 8.900 "V'', 40 176.300 16.600 0.600 0.300 Antenna:3 Azimuth(from true north) q 45 90 135 180,„,.qm,,,•.,225 270 315 Antenna Height AAT(meters) 214.700 96.900 138.400 239.400 ?�1y206•-'�x;39.•800 116.800 176.000 Transmitting ERP(watts) 5.500 0.200 0.500 0.400 tt}§y':`;,0.100 9-00 221.700 101.700 #°d''i 1ix•h� ,'rr' . `�1b"' ,d� ,F'f;'�•u_t phi c ,•�. FCC 601-C Page 10 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA3IQ: '`'$N File Number: Print Date: Location ,.I,atttii"tle Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters) Registration No. 68 40-30-19:0 074-43-47.1 W 30.8 44.2 Address:325 Mick'oint;Road ,. City:NESHANICySTALQN ,County: SOMERSET State:NJ Construction Deadline:04-05-2012 Antenna: 1 Azimuth $om true''riorth 45 90 135 180 225 270 315 Antenna Height AAT ine't rs g ( ) �30:LQ;00 34.600 44.600 30.000 30.000 30.000 30.000 30.000 Transmitting ERP(watts) ,,.y 16.600 32.300 1.200 0.200 0.600 0.200 3.600 94.900 Antenna:2 Azimuth(from true north)> °Qin 45 90 135 180 225 270 315 Antenna Height AAT(meters) .Ll,-v ;30}000 34.600 44.600 30.000 30.000 30.000 30.000 30.000 Transmitting ERP(watts) 03.00 ,1.000 40.500 232.000 77.300 3.600 0.200 0.500 r Antenna:3 Azimuth(from true north)y 0„R 45 90 135 180 225 270 315 Antenna Height AAT(meters) X34°.600 44.600 30.000 30.000 30.000 30.000 30.000 Transmitting ERP(watts) 0.200 C0:400°?., 0.400 0.400 19.400 193.700 125.300 7.800 Location Latitude Longitude °:y. ';=S Ground Elevation Structure Hgt to Tip Antenna Structure m (meters) eters) Registration No. 69 40-56-48.1 N 073-03-37.1 W 68'6 36.0 Address:200 BELLE TERRE ROAD :;N City:Port Jefferson County:SUFFOLK State:NY{r on" ction Deadline:04-05-2012 Antenna: 1 Azimuth from true north '` ' ( ) Q 45 9�;4�"�="-4�ry;1,35 180 225 270 315 Antenna Height AAT(meters) 97.000 97.00053 900 4,63'.800 58.800 56.500 93.200 96.900 �..,A �- Transmitting ERP(watts) 21.100 11.100 1.'500-n"" 0 .0.0. 0.100 0.200 1.800 11.600 Antenna:2 Azimuth(from true north) 0 45 90 •<t3 ' 189 225 270 315 Antenna Height AAT(meters) 97.000 97.000 53.900 58.800 56.500 93.200 96,900 Transmitting ERP(watts) 3.000 30.100 108.000 123 600 48.500 5.500 0.200 0.100 Antenna:3 Azimuth(from true north) 0 45 90 135 180,,.,x,-,,:r„225 270 315 Antenna Height AAT(meters) 97.000 97.000 53.900 63.800 8..$00' "°°,,-56:500 93.200 96.900 Transmitting ERP(watts) 2.600 0.300 0.300 6.300 :t;_56.800 561800 126.900 26.300 FCC 601-C Page 11 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA3.1;Q�4,;:Q7`, File Number: Print Date: �;:;Y . Location ,, '`a:, Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters) Registration No. 70 40-59-37:0 N't 'f 072-10-17.0 W 27.4 107.6 1003631 ,,. Address: SPRING: IREP,,LACE ROAD&ABRAHMS PATH City:EAST HAIvIPTQy;=County: SUFFOLK State:NY Construction Deadline:04-05-2012 Antenna: 1 AzimuthRo•,m hib!e n rth),:�,:p,, 45 90 135 " 180 225 270 315 Antenna Height AATFNteiers) t+' r=a,,.1'0 t' 0 .�.;; : �.9 0 111.500 108.700 110.800 110.100 104.600 103.300 106.100 Transmitting ERP(watts), A 63.100 8.800 0.900 0.100 0.000, 9.900 64.600 rYg�,e v yxr Antenna:2 Azimuth(from true nr(li} 0;, 45 90 135 180 225 270 315 Antenna Height AAT(meters) ,10 s, 0 111.500 108,700 110.800 110.100 104.600 103.300 106.100 g (wafts) ,.•,t, °4;; '0- ,40.800 184.200 229.200 73.300 7.800 0.600 0.200 Transmittin ERP watts 1,. Antenna:3 Azimuth(from true north) , 90 135 180 225 270 315 Antenna Height AAT(meters) 1' ,8:900 r',. .500 108.700 110.800 110.100 104.600 103.300 106.100 Transmitting ERP(watts) 3.700 ,0`3x00 0.400 9.100 78.600 229.200 184.200 37.200 Location LatitudeLongitude ;;Ground Elevation Structure Hgt to Tip Antenna Structure nme`ers) (meters) Registration No. 71 40-56-20.9 N 072-46-40.4 W5 t !" ,,�,�R;293 �_'�, 34.4 1006549 Address:FRESH POND ROAD City: CALVERTON County: SUFFOLK State:NY Construction Deadline:04-05-2012. tY ':r.,., Antenna: 1 from Azimuth true north `'`""'' >. u ( ) 0 45 ,7, 1''35 180 225 270 315 Antenna Height AAT(meters) 61.300 55.800 511''4 OQ 3'S'.100 42.900 38.600 30.000 57.800 Transmitting ERP(watts) 121.700 58.900 9"4•007""\ 0.600, 0.400 0.600 8.600 60.300 from true north)) 0 45 Antenna:2 Azimuth 90 fir 180 225 270 315 Antenna Height AAT(meters) 61.300 55.800 51.000 '°;=.135 ,00 42.900 38,600 30.000 57.800 far_,, Transmitting ERP(watts) 2.600 36.300 172.900 `:J09.20. 0 66.800 8.300 0.500 0.400 Antenna:3 Azimuth(from true north) 0 45 90 135 180,,. ,; ,, 225 270 315 Antenna Height AAT meters 61.300 55.800 51.000 35.100 !" g (meters) �r 2900 fB600 30.000 57.800 Transmitting ERP(watts) 3.500 0.800 0.500 6.700 69.500 26s244,400 173.200 35.800 • vIJ •RA4'tj V 444;'tet.,�Ypx'�{�=r�9��."`,:t'•`r� ", FCC 601-C Page 12 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KN File File Number: Print Date: Location..i;atitude'.:, ,,,:. Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters) Registration No. 72 41-27-619,:2 N`'r.d,:="' 073-38-58.3 W 269.4 39.9 Address:TOPQrlECHQ:ROAD City:Lake Carm`e Coanty'•``P TN State:NY Construction Deadline:04-05-2012 5� Antenna: 1 Azimuth om `Y ) �0 45 90 135 180 225 270 315 �fitrue>no�rth Antenna Height AAT(dieters) 30 800 61.300 110.800 136.700 168.700 112.400 47.600 98.400 Transmitting ERP(watts) '-082.300 56.000 3.400 2.000 0200 2.700 9.400 70.500 Antenna:2 Azimuth(from true nrth),'`0"' 45 90 135 180 225 270 315 i r Antenna Height AAT(meters) 'ii°° x;: 0.$00 61.300 110.800 136.700 168.700 112.400 47.600 98.400 Transmitting ERP(watts) 1.400 17.100 42.700 12.100 0.600 0.100 0.100 Antenna:3 Azimuth(from true north)"' 90 135 180 225 .270 315 Antenna Height AAT(meters) 39':800 61:`300 110.800 136.700. 168.700 112.400 47.600 98.400 y, Transmitting ERP(watts) 6.200 r`0:9QQ;, 4.900 25.900 186.600 238.400 180.200 14.300 Location Latitude Longitude .'":;'. j Ground Elevation Structure He to Tip Antenna Structure nit ers) (meters) Registration No. 73 41-25-55.1 N 073-52-49.7 W -3:45:0` •. 113.1 1010179 :., Address:ROUTE 301. City:PUTNAM VALLEY County:PUTNAM State: 5.'r'Construction Deadline:04-05-2012 ;.. Antenna: 1 Azimuth(from true north) 0 45 9(1;::a>`t ' 135 180 225 270 315 Antenna Height AAT(meters) 181.800 97.100 % 3.300 x„41:95.300 263.600 266.100 240.900 264.800 Transmitting ERP(watts) 3.500 46.400 19,;:000, 2Q3.500 53.800 4.000 -0.200 0.200 Antenna:2 Azimuth(from true north) 0 45 90 x`:135 ` .Y`. 180 225 270 " 315 Antenna Height AAT(meters) 181.800 97.100 153.300' '., 195': OQ; 263.600 266.100 249.900 264.800 Transmitting ERP(watts) 2.300 0.100 0.200 '5$00 ` 68.300 224.800 174.200 35.800 Antenna:3 Azimuth(from true north) 0 45 90 135 180„..,1-�w.ot,y,,225 270 315 Antenna Height AAT(meters) 181.800 97.100 153.300 195.300 /,27.63 � :600"-' 66.100 249.900 264.800 fP,. ! t'� Transmitting ERP(watts) 18.000 0.700 0.100 0.100 '_S 400 7500 237.200 157.100 FCC 601-C Page 13 of 20 August 2007 r Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA3IO:.t':", File Number: Print Date: Location�LAttude, kr:# Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters)) Registration No. 74 41-06- 44'N= =' 072-22-25.1 W 5.5 56.1 �: ei Address:Moore's tTane City:Greenport �`Co.uCntyA SU.F. OLK State:NY Construction Deadline:04-05-2012 45 9 225 270 315 .. 0 Antenna: 1 Azimuth .fromQ 135 18'', e�nort�i) Qh Antenna Height AAT meters `50;000 48.600 49.100 46.900 44.900 42.300 50.000 50.000 Transmitting ERP(watts) t `w 5.400 17.000 13.100 2.800 0.300 0.100 0.100 0.500 Antenna:2 Azimuth(from true norCl�}:. 0;'' 45 90 135 180 225 270 315 Antenna Height AAT meters "'' g ( )69��`q`° ��F$r�0.000 48.600 49.100 46.900 44.900 42.300 50.000 50.000 Transmitting ERP(watts) 3.900 37.900 118.100 91.700 17.000 1.500 0.200 Antenna:3 Azimuth(from true north)" p ,,v;;•4. ,.45 90 135 180 225 270 315 Antenna Height AAT(meters) x#8.600 49.100 46.900 44.900 42.300 50.000 50.000 Transmitting ERP(watts) 0.800 ;,0:2QQ; 0.400 6.900 58.800 144.400 76.000 10.300 - .i',,s1 rF /W ,x,,1 x Location Latitude Longitude ;,. � 'x°:Ground Elevation Structure Hgt to Tip Antenna Structure ;k , �✓' ('1`t1eLers) (meters) Registration No. 75 40-52-34.0 N 073-22-14.1 W 24.4 Addresi:Alvord Avenue ''` City:Greenlawn County: SUFFOLK State:NY Construction Deadline:04-05-2012 Antenna: 1 Azimuth(from true north) 0 45 9QePA "` ,15 180 225 270 315 Antenna Height AAT(meters) 108.5Q0 99.400 b�5;:400 X67,.800 61.400 46.700 91.000 104.200 Transmitting ERP(watts) 81.600 104.400 28.7.0.0` 2.6.00 0.100 0.100 1.300 16.300 Antenna:2 Azimuth(from true north) 0 45 90 180 225 270 315 Antenna Height AAT(meters) 108.500 99.400 05.400 , 67%8A0,,;61 61.400 46.700 91.000 104.200 Transmitting ERP(watts) 0.300 6.100 60.000v 1,$7.100 145.300 27.000 2.400 0.300 Antenna:3 Azimuth(from true north) 0 45 90 135 180 n,-.'_.,,225 270 315 Antenna Height AAT(meters) 108.500 99.400 65.400 67.800 61';400"` %46.700 91.000 104.200 Transmitting ERP(watts) 12.200 0.900 0.200 1.100 =61`4.600 1:0111,100 206.600 96.500 F 4'J FCC 601-C Page 14 of 20.1 August 2007 r � Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA3,10 `,� File Number: Print Date: r,1• f•;•j, Location >Iatifud'e,? ;',r; Longitude Ground Elevation Structure Hgt to Tip Antenna Structure 3, (meters) (meters) Registration No. 76 40-57-22:OT `' 072-58-25.0 W 65.5 40.5 1013195 Address: SYOS,�E; ROAD•,,. City: SOUND Cpwo`O, : SUFFOLK State:NY Construction Deadline:04-05-2012 4f•l e. \ �•,V f Antenna: 1 Azimuth,from ttie'riorth)., 0; 45 90 135 180 225 270 315 Antenna Height AAT(meters)P ;.:,',,90'200 90.200 49.300 64.900 56.800 51.100 `78.800 90.200 Transmitting ERP(watts) 14.800 2.300 0.200 0.100 0.200 2.200 15.100 Antenna:2 Azimuth(from true nortli ;.,�•,i~� 45 90 135 180 225 270 315 Antenna Height AAT(meters) ;`sy�?''''90. 00 90.200 49.300 64.900 56.800 51.100 78.800 90.200 Transmitting ERP(watts) °s.';.;.'2SQ0 ,32.500 162.900 208.200 57.300 5.100 0.200 0.100 Antenna:3 Azimuth(from true nort(i) 0 n-'';�'_���45 90 135 180 225 270 315 Antenna Height AAT(meters) x`90;;200 0.500 49.300 64.900 56.800 51.100 78.800 90.200 Transmitting ERP(watts) 2.300rj`2f0 9 0.200 6.000 62.900 208.200 159.200 27.700 Elevation Structure Hgt to Tip Antenna Structure Location Latitude Longitude (meters) (meters) Registration No. 77 40-52-10.0 N 072-34-35.0 W. r:.5t9=w,;;<. 51.8 1003626 Address:OLD COUNTRY ROAD&EAST END AVE City:EAST QUOGUE County: SUFFOLK State:N,Y ?` Construction Deadline:04-05-2012 Antenna: 1 Azimuth(from true north) 0 45 90:-:-" 135 180 225 270 315 Antenna Height AAT(meters) 83.300 86.400 8.7:100 $9.900 89,700 85.100 48.400 74.900 Transmitting ERP(watts) 242.800 148.800 30'+ ,QQ` 3. 00 0.200 4.300 . 30.900 145.400 :=u,'• , Antenna:2 Azimuth(from true north) 0 45 90 (""t4� 135.""`t,;; 180 225 270 315 Antenna Height AAT(meters) 83.300 86.400 87.100 89`.90.0';.';:4 89.700 85.100 48.400 74.900 Transmitting ERP(watts) 0.200 4.300 30.900 .4.00 242.800 148.800 30.200 3.700 � Location Latitude Longitude Ground Elevation StructfireHgt;fo.Tip Antenna Structure (meters) (mete'rs) ;.;:; Registration No. 78 40-58-10.8 N 072-20-46.6 W 77.1 91:4'i :.. ,.; 1014849 Address:MIDDLELINE ROAD - e`'^' `v City: Sag Harbor County: SUFFOLK State:NY Construction Deadline:04=x05 2012 Antenna: 1 Azimuth(from true north) 0 45 90 135 180 t;-•' 225 `..'°0 270 315 Csi.� +!!sal Antenna Height AAT(meters) 123.900 125.700 107.900 122.200 122.9003 111.4'66? 124.400 123.900 Transmitting ERP(watts) 68.000 221.300 114.700 9.400 0.800 ` 4.1100Y ;:0,:100 4.500 1 110, t}t:si=., =� FCC 601-C Page 15 of 20• August 2007 Licensee Name: NEW CINGULAR WIRELESS PGS,LLC Call Sign:KNKA3 0-:1'.; File Number: Print Date: Location,aIatiLongitude Ground Elevation Structure Hgt to Tip Antenna Structure >' (meters) (meters) Registration No. 78 40-58- Q'r$ V` s'`J 072-20-46.6 W 77.1 91.4 1014849 Address:MIDDY ALINE RQAD City:Sag Harbor'`�Count" SUFFOLK State:NY Construction Deadline:04-05-2012 Antenna:2 Azimuth tr `,from ue„iorth),.<-,0•,.• 45 90 135 189 225 270 315 Antenna Height AAT meter's) r :;.;,,1234*0 125.700 107.900 122.200 122.900 111.400 124.400 123.900 Transmitting ` "s'7 `;z ERP(watts) �`�--0.100 1.800 39.700 184.500 153.800 16.600 1.500 0.100 Antenna:3 Azimuth(from true ngrttiY''"`10rr'z', 45 90 135 180 225 270 315 Antenna Height AAT(meters) ;; `'.j• :,12 900 125.700 107.900 122.200 122.900 111.400 124400 123.900 Transmitting ERP(watts) `'$...,,i;060 , 0.700 0.100 0.100 6.800 77.200 242.800 88.700 Location Latitude LongitulaeGround Elevation Structure Hgt to Tip Antenna Structure �'Y r ,,(meters) (meters) 79 Registration No. y .--_• YAG. 40-43-03.0 N .073-16-27.0 8.5 45.7 1013196 Address:ORINOCO DRIVE City:BAY SHORE County: SUFFOLK `!tate\ Construction Deadline:04-05-2012' Antenna: 1 Azimuth(from true north) 0 90"::;s:;W 135 180 225 270 315 Antenna Height AAT(meters) 30.000 32.400 45 60`0 46.500 46.500 46.400 33.100 30.000 Transmitting ERP(watts) 231.800 103.600C,J-2:200. 0.800 0.300 1.000 14.600 108.400 Antenna:2 Azimuth(from true north) 0 45 90 "NJ35 180 . 225 270 315 fir Antenna Height AAT(meters) 30.000 32.400 400046.500 46.500 46.400 33.100 30.000 Transmitting ERP(watts) 2.500 32.500 162O,Q 20.8.200 57.300 5.100 0.200 0.100 "^.•fttj�t;. Antenna:3 Azimuth(from true north) 0 45 90 �`"11-1,fil3$'"'"`` � 180 225 270 315 Antenna Height AAT(meters) 30.000 32.400 45.600 (xA :00" 46.500 46.400 33.100 30.000 Transmitting ERP(watts) 2.300 0.200 0.200 '600b; " 62.900 208.200 159.200 27.700 Location Latitude Longitude' Ground Elevation Structrtre3Hgt;to,Tip Antenna Structure (meters) (meters) tlr, Registration No. 80 41-30-55.0 N 073-39-48.0 W 307.8 52.4''I <:;at 1011871 Address: 183 DENTON LAKE ROAD (a- , City:HOLMES County:PLJTNAM State:NY Construction Deadline:04`ZQS�''2012 Antenna: 1 Azimuth(from true north) 0 45 90 135 180 'w'`225a,' ; 270 315 Antenna Height AAT(meters) 99.000 118.600 101.400 154.300 178.700-;$ 96.0�0:'s'`"°� 141.200 185.800 Transmitting ERP(watts) 17.600 13.800 4.900 0.500 0.100 0 40Q' f4 800 13.500 FCC 601-C Page 16 of 20 August 2007 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA341.0�9 , File Number: Print Date: Location L,Ad ;, Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters) Registration No. ar y > 80 41-30- 50 N 5 `' 073-39-48.0 W 307.8 52.4 1011871 J. Address: 183 DNfON LAKE ROAD City:HOLMES vfCount:, 14TTNAM State:NY Construction Deadline:04-05-2012 ,,,,e NO Antenna:2 Azimuth�(fromtrue'riorth),O, 45 90 135 180 225 270 315 Antenna Height AAT(meters) x '`99 000 118.600 101.400 154.300 178.700 96.000 141.200 185.800 Transmitting ERP(watts) < , ;- \ 0,100 0.800 7.100 10.900 2.100 0.100 0.100 0.100 Antenna:3 Azimuth(from tree nort );>: 0 '`' 45 90 135 180 225 270 315 Antenna Height AAT(meters) :''° y'99.p,0;0 118.600 101.400 154.300 178.700 96.000 141.200 185.800 Transmitting ERP(watts) '` 01`00 0.100 0.100 0.400 7.200 41.600 30.400 3.500 Location Latitude Longitu`de;, '`N Ground Elevation Structure Hgt to Tip Antenna Structure '' :'• (meters) (meters) Registration No. p'``>„i.�•,..dry p.4 81 40-35-19.3 N 073-41-49.1 a` "' 1.5 31.4 Address: 1039 West Park Avenue City:Long Beach County:NASSAU StateiclY -Construction Deadline:04-05-2012 Antenna: 1 Azimuth(from true north) 0 45 �;;1':r,'= `` 90:'?; 135 180 225 270 315 ati lF1's•• SS Antenna Height AAT(meters) 30.000 30°000 3,0:500 31.100 31.100 31.100 30.100 30.000 Transmitting ERP(watts) 242.800 117.500l 8: 00 1.200 0.800 1.300 17.200 120.300 Antenna:2 Azimuth(from true north) 0 45 9,0, s=' 35 180 225 270 315 Antenna Height AAT(meters) 30.000 30.000 3�0,;500 1+.100 31.100 31.100 30.100 30.000 Transmitting ERP(watts) 2.700 36.600 18 :40, 222.300 67.900 8.500 0.500 0.400 ( ) 1;35' ;'a 180 225 270 315 Antenna:3 Azimuth from true north 0 45 90 �•;°.;; tt Antenna Height AAT(meters) 30.000 30.000 30.500 ;131. ,- ; 31.100 31.100 30.100 30.000 .. Transmitting ERP(watts) 3.500 0.800 0.500 <;6-,,7,00 69.500 227.400 173.200 35.800 h ^3•h Location Latitude Longitude Ground Elevation Struct ri i'J, t to.Tip Antenna Structure (meters) (meters) Registration No. 82 40-36-04.9 N 073-30-12.4 W 1.2 3,41'a 4 . Address:JONES BEACH MARINE THEATER ={ City:WANTAGH County:NASSAU State:NY Construction Deadline:44-;'0' 012_ Antenna: 1 Azimuth(from true north) 0 45 90 135 180 y225'` ,, :, 270 315 Antenna Height AAT(meters) 30.000 30.000 30.100 30.200 30.20M,',-,. 30.200;', 30.000 30.000 TransmittingERP(watts) 242.850 117.500 18.000 1.200 0.800 "�'„1"3Q0°" 2117.200 120.300 ny FCC 601-C Page 17 of 20 August 2607 J 1 ; Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA31:0;;:.',,,," File Number: Print Date: Location *I..... u'd'e =`:• Longitude Ground Elevation Structure Hgt to Tip Antenna Structure (meters) (meters) Registration No. 40-36-Q4:9 i`1 073-30-12.4 W 1.2 34.1 Address:JONES;B'EACH:•MARINE THEATER City:WANTAGH County:I4, SSAU State:NY Construction Deadline:04-05-2012 Antenna:2 Azimuth from north 45 90 135 180 225 270 315 Antenna Height AAT in'eters) t _30 000 30.000 30.100 30.200 30.206 30.200 30.000 30.000 Transmittin ERP watts tf} g (_ ) 2 700 36.600 181.400 222.300 67.900 8.500 0.500 0.400 Antenna:3 Azimuth(from true n rth);y'QZ 45 90 135 180 225 270 315 Antenna meters AAT Height ' g ( ) °,����'�''�= 30�d00 30.000 30.100 30.200 30.200 30.200 30.000 30.000 Transmitting ERP(watts) `;'t 3;500 0.800 0.500 6.700 69.500 227.400 173.200 35.800 Location Latitude Longitude.;,,�.a i. Ground Elevation Structure Hgt to Tip Antenna Structure t ,,,Z* (meters) (meters) Registration No. 83 41-15-38.7 N 072-00-51.9 "Y' "�i'23.2 20.4 ,,;''�p't, `'bis Address:JCT ORIENTAL AVE&ETTICK ,rVEti, r,,.y'} City:FISHERS ISLAND County:SUFFOEK jr �S ale:NY Construction Deadline:64=05-2012 ( ) 0 45^`�'',," 0'� 135 180 225 270 315 Antenna: 1 Azimuth from true north Antenna Height AAT(meters) 30.000 3100 3'80, 33.800' 33.800 33.800 33.800 30.000 Transmitting ERP(watts) 0.800 14.900;,;;:5;13'400 1.1Q0 0.100 0.100 0.100 0.100 Antenna:2 Azimuth(from true north) 0 45 9d,r' ' -'x;135 180 225 270 315 Antenna Height AAT(meters) 30.000 31.600 33{i00 435.800 33.800 33.800 33.800 30.000 Transmitting ERP(watts) 0.100 0.100 O�1OT0' 0`.1 0.200 1.500 0.900 0.100 rs' Antenna:3 Azimuth(from true north) Q 45 90 135"" '• 180 225 270 315 Antenna Height AAT(meters) 30.000 31.600 33.800 133Q,Q+`✓j 33.800 33.800 33.800 30.000 41 Transmitting ERP(watts) 0.200 0.100 0.100 0.100 0.100 0.400 0.900 Location Latitude Longitude Ground Elevation Structure.Hgt,to,Tip Antenna Structure (meters) (meters) "<<; Registration No. 84 40-57-46.4 N 072-40-46.9 W 21.9 45,,7A, Address:900 Reeves Avenue �, R, City:RIVERHEAD County:SUFFOLK State:NY Construction Deadline%_q,fL 5-2012 Antenna: 1 Azimuth(from-true north) 0 45 90 135 180 270 315 s-=;_•' lei-.,,1 Antenna Height AAT(meters) 60.100 60.100 52.600 50.800 40.700 A._: 44.6,0 33.100 60.100 Transmitting ERP(watts) 146.3'00 65.300 7.700 0.500 0.200 t`4000 'J 9:200 68.400 S, },'�r:Yf--•+'J.t'"1,t"'4 i FCC 601-C Page 18 of 20 August 2607 i J r Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA3,IQ;`:-; File Number: Print Date: Location,, Longitude Longitude Ground Elevation Structure Hgt to Tip Antenna Structure F'"` `,_ ''. ` ;' (meters) (meters) Registration No. 84 40- 072-40-46.9 W 21.9 45,7 Address:900 Reeves Avenue,,.• City:RIVE RH$AD r,4: ourity:'r,§VFFOLK State:NY Construction Deadline:04-05-2012 Antenna:2 Azimuth'(fiamtru `,riortli) .,p:, 45 90 135 180 225 270 315 ''a,�d; »'i .•...',z Antenna Height AAT(meters) 60"4 ,t,:,r 100 60.100 52.600 50.800 40.700 44.600 33.100 60.100 ra,5,•��Wi^• Transmitting ERP(watts) f ,i ;r•" .r 2.500 32.500 162.900 208.200 57.300 5.100 0.200 0.100 Antenna:3 Azimuth(from true north),;,, p 45 90 135 180 225 270 315 Antenna Height AAT(meters) ;x}"„ ,a60, U0 60.100 52.600 50.8Q0 40.700 44.600 33.100 60,100 Transmitting ' ERP(watts)) �.;:;.'�,2,:300 ,0.200 0.200 6.000 62.900 208.200 159.200 27.700 Location Latitude Longitude`"-gcs` Ground Elevation Structure Hgt to Tip Antenna Structure meters meters Registration No. 85 40-45-33.3 N 073-11-30.4 :>`:,' 1.9 71.9 Address: 170 FEDERAL PLAZA , " } City:CENTRAL ISLIP County: SUFFOL G;;$tate:`NY,>. Construction Deadline:04-05-2012 . Antenna: 1 Azimuth(from true north) 045;x;:.";z`'`✓90r;;s 135 180 225 270 315 Antenna Height AAT(meters) 34.300 30.400 55':20. 63.500 63.400 62.500 41.900 30.000 Transmitting ERP(watts) Q 242.800 117.50.0;;11&:000., 1.200 0.80 1.300 17.200 120.300 Antenna:2 Azimuth(from true north) 0 45 9.O::a i 4-35 180 225 270 315 Antenna Height AAT(meters) 34.300 30.400 5,5,200 x:63'.500 63.400 62.500 41.900 30.000 Transmitting ERP(watts) 2.700 36.600 1kf;4'Q0, 22,2.300 67.900 8.500 0.500 0.400 Antenna:3 Azimuth(from true north) 0 45 90 ';"_X3$ 180 225 270 315 Antenna Height AAT(meters) 34.300 30.400 55.200 ;63:5OOta 63.400 62.500 41.900 30.000 Transmitting ERP(watts) 3.500 0.800 0.500 69.500 227.400 173.200 35.800 ..x�. Control Points: Control Pt.No.1 Address: 87 W.PASSAIC STREET City:ROCHELLE PARK County: State:NJ Telephone Number: Control Pt.No.2 a,• f i'?` ;y Address:Manhattan Switch,810 7th Avenue '' City:New York County: State:NY Telephone Number: :a' FCC 601-C Page 19 of 20 August 1001 Licensee Name: NEW CINGULAR WIRELESS PCS,LLC Call Sign:KNKA310 ."r:ht File Number: Print Date: Waivers/ 0"i"" This license is conchioned-upon compliance with the provisions of Applications of AT&T Wireless Services,Inc.and Cingular Wireless Corporttoii For Consent to Transfer Control of Licenses and Authorizations,Memorandum Opinion and Order,FCC 04-255(rel.Ocf126,2004):. - Commission approv f'tlit application and the licenses contained therein are subject to the conditions set forth in the ,.., �f Memorandum Opinion;and Order,adoped�on December 29,2006 and released on March 26,2007,and revised in the Order on Reconsideration,adopteil'and released:6hr Narch 26,2007.See AT&T Inc.and BellSouth Corporation Application for Transfer of Control,WC Docket No.06 74 T -~,.,orandum Opinion and Order,FCC 06-189(rel.Mar.26,2007);AT&T Inc.and BellSouth Corporation,W Dob et No7:06-74,Order on Reconsideration,FCC 07-44(rel.Mar.26,2007). The action taken with respect to 'pplic tim 0004589004 does not preclude or prejudice any potential enforcement action regarding this Application,and bes,not�viistit4te a waiver of any of the Commission's rules with respect to this Application. .;,V, FCC 601-C Page 20 of 20 August 2007 . .,.:. ,:..'. `.: . :, : . Y :. ,I.. '' Thai M not anoilicial FCE lIconae:It is_a record of pnlilie 3afon containad in tha,FCC's l�camsing dataliasa an tha date that this refatrace; '; r c was elated ,wcasas wd a FCC,ru e' iha ' ' �Py.., Ste. ., ;. r P m,Postmg,'or dteplay of en PCC Iieeasa,flus doc1.ument maY�4t he used. m.place of an:ofFidal FCC license: :,, . '. .. ._ ,. , <.,.,, j .... .. .. .. A. .:. -.... .; I I .. .. : .. v ,... ,.. ..- .e.. .. ., .., .... .. :.... .::�i. au rrc r...,..,: '; .. , .. . . °` �; .:':I ., Federal Commanucatllolns Comm><ss><on ,YL y;x a f x ti I. _ WireIese Telecommunications Bnrean ' �" 11►M �S�°"� 1. �tADIO STA TION'AUTS.OItTZA.TTU�V .,. ... ...:::.......:, . . ,, .,r,,.: :• ,.-;:;, :: :: w r: CENS 1 . LI C Na S 'PCS C W S T.L ,::::. :.... 1:1 N l]I:AR. ,.: > ..... N .., ,, . . < ..,..: ..:. ,.;,., 4,. X.<, . S...:.t..r:.'. ., ,. ....- .......... ..... .... ..., s .,...: .St .: .. i. .. .. ...,.. ...-..,n.....,...... , ,.., .. ... ... .. ..i:.,:.,.... ... .: .. ..... .. r ... ..... .. .. .. ..> X.. �.':::...:':..:''.. >.::'. '::.::.� ::.'. A Oa8 2 �_: :::...> _. . . . .. F.. :WQ 9 . G SS Pt✓ LLC N C1N S NEW ULAR iRELE ,.,... W . ..':,. $6 1 LE ACX�11 RIVE MS A� 11 , 'CW=•PC5'Broadland `''``�: O TX. 24.` PLAN 75 0 ,.,... ,...: _ ,. �,, ,.:._, i c# _;. .;.......:. ::a � ` .. .. .>...., .. .. a..s .. .... .,.. v e ....-: x... ,:i: a x• yr `:f:: ✓' F e rat►on,Number. DO 329 ':192:. ' CCR . . .p E :.,.>. *:::::.:...... . . :.... . ... .. ... ... ..: ".: r:..::. .. , .:. . .... . ., .. ::::.. ,::. . ........ ....... .. rn . G a t Date ;. :.,::.., Effective Da :.....:.:.. t ... e .., ..,. >,.. ..-.,..... .. .. ,. , :;.:::: Expiration`Date'':;: ;:; . Print Date : '"': %:.... ...:..... 2 2,1 1:. .... Q .... D3-16=2010:.': :_^. T 4=2014: .> . :.:'.:.......::..I...: ,: ,.,:_.. ..... r„� t::: ...,... , E „ ...:....... .. ,, .. o?;::.::.::<:...:'...::. ..:::::...:.. ,,.:,x,,_�., y:.,, arket umber .., :':'.:';- :::... Sub-lVtarket Desi afoti M ,. ,1,................,.....,. Chagiikl luck. :: :>;:: : ;'. .`''` �..... .. �5� ;4:.�:.:;�. .... ...,.., ...: :r. ::' .'if'.:.i R ..:... .. ,. ... .... :... .....�:. ,,. r <„.., Market`"Name::';': <;::::, ::.. .,. . i. ;'..: :. . .............: -Tr ".....%. OT' a; "-.'1st Bnil1.d-out Date ..`.': :,;:::':,.' - 3cd° d-out Date:" " 2nd Build out Date..,.::;<,,, .; . :.. .;. . ;4th'B d-out Date .., .. ......,. . . .. ... .1 .,. . ::.: ,.,..... ... Waivers.Conditions. xr N ,. ,.._... . 1. ,. ,. NE , . , 1..1111:. e: �.: . , , _.,.. .;: ... -,,. i..,r ... : ,. ... . :...v.. .: ... ., ... t,,. �:; , :k::. % , ... . , v, -:. - ., s. : �Y, Condition's' _. . , ,,:. : , . , " . -Puf'susnt to:§309. of the:CommiWcations;Act of;1934,as amended;47:U:3 C:: 309 ,i 'is',license is su, ect to.the'_ .,, (h). §.. �) , bj , following conditions This license shall'not vest in the licensee+any Tight to operate., a station`'nor anynght in the use,of the„', . .. . ;frequencies designated in the.lkense beyond the,term,thereof nor in any'other manner thanauthoriae l:herein 'Neither the:.., . . < ;license nor-the right granted.thereunder;shall be assigned or otherwise transferred in violation of the'Communf;a&oris Act.of . 1934,as"amended.'See 47 U:S:, §310(d). _Tliis license is subject in terrns.to the right of us', control co>jferred by§706 of ... , . ... - ,. the Comrriumcations Act'of 1934,as amended.,:See 47:U•S.C•.§606. ,, .; ,. .` This.license.maynot authorize operation thiou hbti the entire e '� sp py ... p g g graphic,area.or ectrum identified qn the liardcg version . To view the specific geographic area and spectium authorized by this license,'refer I the Spectium and Market Area informs under the,Market Tab of the license re11 cord,in the Universal Licensing.System.(ULS). To view the license record;go'io.the_ULS homepage at http:#vAreless.fec:goy/uls%index:htm?joti=home and select'Ucense.Search"::;Followahe instructions;on how to search for license-info%rmation. .'� : _ "' . .. , . . , .,. , .1. _ 1.• FCC 6.. MB . Page 1 of.1 I . April 2009 r.y REFERENCE COPY ,." . ..:.''.: '':.:.:: ::::.: :.':., Ttits.is not'an:of tial FCC Uceaee;It is;a record of public wformWc6l coutainedin the FCC's lic6i*.database.on the date that.this refaceace copy was fed.1n casae where FCC rulas require the preshmiation,_posting,or display of an FCC license;this document may hot b®used in place of as official FCC-liccnsa; FedierAl,C6bibkn>lcabons Commission.:: Wireless"TeleeommunicationjBureau . r ' STATION;RUTHORIZATION. • 0CEr1s` .:,i1gE- wC1K6ULAR WIR'=SS PCS LLC call Si" e: um Fil N or.: TTN:PCC QROUP:;":= WPSI 626: .a 77 NEW;CINGULAR.WiREIESS ij' S,>LLC," :::': >. 'o 5601':LEGACY:DRIVB CW. Broadband PF.ANO TX 75024;:.:;:;':':; :.:,.:.: , .. `.FCC ItZe ation Number: RN : 0003Z9L192'. Grant.Date. ,, .... ::;Effective U Ex ifation Dafe:: Print_Date" k....:..::.::..: ...:: : ;::. :.:;.;.::;: :. :' 4-2014: ,,'.::;'>.:;'.',.. - .i :: ketNum er.....,;::>' Sub-MaikefDeg Mar b h`an ck" :.; u o ...... :.....: Cyr�..;,ew ..... .: .... 1st Build=out Date':.;;; ;;;; :;-;;;: 2dd But7d-out Date::::;:.." rd,Bnild-0nf;Date': :..;:.. . "4th Build=outDate l2 1 . 999. .... E Waivers/Conditions: Spectivm ease,as with this license. See Spectnnn I:easing Arra�genien'i-Letter dated]2!07/2004 and"File`No: 0001757186:. , ,s Spectrum Leasing Arrangement associated with,file number 0001757186 was'exteaded t6Ol/05%2009. See file number 0001885143. Conditions: Pursuant.to§309(h)"of.the Communications Aaof 1934,as amended,'47-U:S.C.§309(h),thisaicense is subject"to the following conditions: This license shall not vest in the licensee any right to operate the stat on'iior any right:in'the use of the frequencies designated in the,license beyond the term'theieof nor in any other manner'than"authorized her ih;'iNcither the license nor the right granted thereunder shall be assigned or otherwise transferred in violation,of,ihe;.Coriimuniaatfons Act of ' 1934,as amended."See 47 U.S.C;§310(d). This license is subject in terms to the right of use of control:conferred by§706 of the Comm unicatioris`Act of 1934,as amended..See V U.S.C:.§606. This license may not authorize operation throughout the entire.geographic area or spectrum identified;on"the hardcop',,'rsion." To view the specific geographic area and spectrum authorized by this license,"refer to the Spectrum and Market;k information under the Market Tab of the license record in the'ilniversal Licensing System(UI,S), To view the license record,,go to the ULS homepage at http, wireless.fcc:gov/uls/index.htm?job4ome and select"License Search". Follow the instructions on how to search for license information. FCC 601-MB Page 1 of 2 April 2009 LicenseeName: `NEW:G7NCiULAR' IRMESS PCS,:UC Call W6g F Number: "Pr1nt Date Commtssion:a roVal'of?lnsra".jication:ettd the liceiises;.aaitained therein are eub'eat to.the conditions set foitli'in the p pp.:. ]., -to, ......:. .. P. iz6n"and,Or er ado-ted oa Decgmber 29,.2006 an case on- `6 26.2007,and revise"d:;` . :Memorandum t� ui the'';Oraeroii Reconsideiration.ado ted end released on:March 26 200,7:>See AT&T.Inc:.and 13el1Soiif} . 6. P oration A'PP Itcahon A. of Control;WC Docket No.06,74,Mgmafandoin"Opimon and'Order,PCC 061S9(t6, Maf 26,2007);AMT Inc.and BellSouth Corporstioti WC DOO,etNo.06=74,"praertui,Recanaldaiution,:FCC.0,,7-44.(rel.Mar_26 .2007).' :.:: IV 4, , : 2. : 4. r. y , r.. FCC 601-MB Page 2 of 2 April 2009 ` , ; . " . � 11*1 i� .:�,.....:! . I . .-.I .. . .: . ,� --I I. L.I : : - . z�, REFEREhICE'CORY >::<:'I h's ie Ao an fRuW:FCC ficensb.lt is a eaoi�d of lie iaforinetlon.contaiaed an fhe.l?Ccs li -.:".::i-*;- ►,.-.:..::..1:.:: p... .:R� ca�ist-g'dafaiisee anafie date that thjs nnerence :`. ..'-:`., ,.., <: ,' . copy was generated:In;cesca wheia FCC rules mquite theprosontation;pasting;or:display of an 1tCC lipepse,this document may not;bo+used m place df as of6dal FCC licence ;.•. -+� ` �, ,k," -'' Fed'eraX Commtpiiaiscal�ons Coi ss><on" o �,: ,: :'_,:.;. , . . W ,.....,. .. ,. , ;,,; REFERIIv CE COPY::' This isnot an official oiCc license.Itis aiecord:of public,information contained m the FCC's:licensing databeae:on the date that f6is reference In cases where FCC nde* iaqume fhb proserdatia': osthr or l of au FCC livens this document ma notbe riled ' copy was generated." P. F�," �P aY 4 Y in pleca of in OR FCC lMease: ;' hot, Federal Communications Coinlnission Wireless:Telecommunicatlous Bureauo ; .. w , rwissRADIO STATION AUTHORIZATION .,,::.. .r i10ENSBE: ":.T&T:M0111L1TY 3PBCTRUM.LLC : ;Ca S' :. . :CIROUP,; WQN424. AT&T MOBIL=SI?ECTRUM LLC dio Sei.10. " J" rol e 5601 L130ACY DRIVB;MS:A 3 '"WY 700 MHz Lower Band(Bloeks A," B,$ FCC atlon:Number s 0014980726;' r..'; Gr t D fe' tiVe fDx irati n"Date: print Date;':::': " 01=06-2009 03-1;6-2010 06-1 : 3.2019 ::.... . Mar umber .,. ,kat..N. 0 0 CM I ' A e am,e' Mark k M .:": .•:..:...:....<: > ::::::: ::Neal:York;fiNY-NJINasseu:Siffoll: :�. ;1st Build-out Oak' 2nd Build-out'Aate•` _', .: Build=out Date; 06:13,2013.:' : '.." " ,..:' 06,:13 2019,:..• :.�� a"..:::, _. ;": .::::. . .. :....:....::. r ;..' Wa1Ve nditlon 6/CQ B. Ifthe4hcilities author�zed.herem are used to,provide bib'd cast_o erations,wlipther exclusivel.,or:in.combination;with other y servrces,the�licensee;must seek renewal.of the license either,within eiglityears"from the commencement of the.liroadcast serYice`or witlnn theaeiin of the license had the broadcast:service not been ovide whichever, enod is shof,CT-,in len 47 CFR.§27.:1"3 pr d, p gth See. .roe. • . . Conditionsi Pursuant to§309(1i)of the Communications Act of 1934;as amended,47 U.S.C.§309(h),thisaicen�a.is subject to the fo]lowing conditions::This license shall not vest in the licensee any right to operate the station nor.any right in,the use of the,. frequencies designated iri the license beyond the tern thereof nor'in any-other manner than authorized:herein.,Neither the ' license`nor.the right-granted thereunder shall be.assigned or otherwise transferred in violation of the.Commrinications Act of 19M,,as amended: See 47 U.S.C..§310(d).-This license'is subject in tenns.to the right of.use'or control'confe red_by§206 of the Communications Act of 1934,as amended. See 47.U.S.C.§606. This license may not authorize operation'throughoui the entire geographic area'or spectrum identified:on the`hardcopy;version. To view:the specific geographic area and spectrum authorized by this license,refer to the Spectrum and.Market Area information under the'IMarket Tab of the license record in the Universal Licensing System(ULS). To view the license record,go to the ULS homepage at http://wireless.fcc.gov/uls/indez.htm?job=home and select"License Search". Follow the instructions on how to search for license information. FCC 601-1V[B Page 1 of 1 April 2009 p'EMRFn10E COPY... ;, :::,,'. �':'.... ,,.•-. : , ,. . This;is not ao Wracial FCC license:'1t ie;a zecotd:ofpublic informadoa captained in the FCC's.cedsing database on the date that this rofbienca copy.was generated:In,cease where FCC.ntlestequn the pTeseion,posting,or.display of as I?CC:lioense,this doi;umont may not ba used" . ".. hi place of;an official kC lieeose. Federm al Comunications Commission R!ireleee T.elecommwmcationa;Bureau cb CA RADIO'STATION AUTHORIZATION LICBNSEBi.-AT&T>MOBILITY:IlLLG- -..: .. ; . ..::. . ... ........ u •Call Sign'• FIIe Number FC I,< C GROUP P .. . .. ,' .... - WWU 'AT&TMOBIIITY II:LLC; 948 • 5601:LBC3ACY DRIVB; L wei Band': loc1�'C PLANO.TX:75024 D). : ........:.. e . . 007698 233 CC lte a n'N umb r 2 F Bo Grant Date. Effective-Date y irationDate PriiitDate ,. O1-24-2043 03 064320.19. . :.ar:CkMetA.Numbe . Sub-MrkeF77777M.. .,ams,::":..,:";...:'. ::;::' :.-::..::.:,:::.-._:::.:: :: : .::;:;::::::'.:'::. -.•.: : . .. lst Build=out Date;;<;; 2nd Build-out Date :::: ;.; ;3rd Build-bid Date:.;: 4th Build-out Date 06-1340.19 Waivers/Conditions :.... If the facilities autlionzed herein are used:to provide,broadcast erations,.vi!Nether;eiiclusivpl :or,in:combination with,other Y . "services*'the:licensee iniust.seek renewal of the license'either'within eight yeurs`from.the'commencenight of the broadcast'.,.,' service or'w fl tile,term of the license had the.broadcast service.not been:rovided;whichever enod is shorter in len See P , , P . 47 CFR§27.,13(b):;. Operation'of t6,iciliti' authorized herein;.are subject to the condition that harmful'interference,.may.not be caused to,.b must be accepted from UHF TV transmitters in"Canada'and Mexico'asIdentified in existing andany:future agreements with those countries: " Conditions: .` Pursuant to§309(h)of the Communications Act of 1934,as,amended,4TU.S.C.§309(h),thisaicense is subject to the following conditions: This license shall not vest in the licensee:any right to operate the stationnor`any right in the'use,of-the frequencies designated in the license beyond the term thereof nor in any other manner than authori ed l'ereiri:'Neither the license nor the right granted thereunder"shall be assigned or'otherwise transferred in violation of.the Communcations'Act of 1934,as amended. See 47;U.S.C:§310(d). This license is subject in terms to the right of use 6f control:conferred by.§706 of the Communications Act,of.1934,as amended. -See 47 U.S.C: -This license may not authorize:operation throughout the entire.geographic area or spectrum identified;on the"hardcopy:Version. To-view the specific geographic area and spectrum authorized by this license,refer to the Spectrum and;Mark'k Area information under the Market'Tab of the license record in the Universal Licensing System(ULS). To view the license record,go to'the ULS homepage at h"Ilwireless.fcc.gov/tils/index.htm?iotrhome and select"License Search". 'Follow the instructions on how to search for license information. ` FCC 601-MB Page,1 of I April 2009 REFERENCE COPY ` This is not an official FCC license.It is a record of public information contained in the FCC's licensing database on the date that this reference copy was generated.In cases where FCC rules require the piesentation,posting,or display of an FCC license,this document may not be used in place of an official FCC license. Federal Communications Commission w Wireless Telecommunications Bureau 15 RADIO STATION AUTHORIZATION C�E•1� v LICENSEE: T&I`{MQ ILITY SPECTRUM LLC �rrl'�t� Call Sign File Number ATTN:REGINALD OBE" CID WQIZ617 AT&T MOBILITY SP)rCTRUIvI;TLC C Radio Service 2200 N.GREENVILLE A WY-700 MHz Lower Band(Blocks A, RICHARDSON,TX 75082`;'; B&E) FCC Registration Number 00148076 4y t` � (F�� 1r Grant Date Effective Date>), Expiration Date Print Date "kJ06-26-2008 11-29=201'2 ? 03-07-2021 Market Number : ' Channel Block Sub-Market Designator BEA010 'WF vim r 0 Mar,16 ame New York,' o Ne s,apr,-Long Isl 1st Build-out Date 2nd Build-out Date '`s;`: 31ri1 Build-out Date 4th Build out Date 03-07-2017 03-07-2021 Waivers/Conditions: If the facilities authorized herein are used to provide broadcast operations;,wether exclusively or in combination with other services,the licensee must seek renewal of the license either within eight years from the commencement of the broadcast service or within the term of the license had the broadcast service not been provided,whichgyer period is shorter in length. See 47 CFR§27.13(b)• r Conditions: Pursuant to §309(h)of the Communications Act of 1934,as amended,47 U.S.C. §309(h),'thitticiaseF is subject to the following conditions: This license shall not vest in the licensee any right to operate the statiori'nbr anyfigll,in the use of the frequencies designated in the license beyond the term thereof nor in any other manner than author•zed f­'ftiii',Neither the . license nor the right granted thereunder shall be assigned or otherwise transferred in violatiotif 1heCommilpicati6ns Act of 1934,as amended. See 47 U.S.C. §310(d). This license is subject in terms to the right of us e r cod trc l;eoi ferred:by§.706 of the Communications Act of 1934,as amended. See 47 U.S.C.§606. This license may not authorize operation throughout the entire geographic area or spectrum identified on,theYacdGb'"py�;yersion. To view the specific geographic area and spectrum-authorized by this license,refer to the Spectrum and;lVTarket'Area informatio under the Market Tab of the license record in the Universal Licensing System(ULS). To view the license record,go to the ULS homepage at http://wireless.fcc.gov/uls/index.htm?job=home and select"License Search". Follow the instructions on how to search for license information. FCC 601-MB Page 1 of 1 April 2009 REFERENCE COPY This is not an official FCC license.It is a record of public information contained in the FCC's licensing database on the date that this reference copy was generated.In cases where FCC rules require the presentation,posting,or display of an FCC license,this document may-not be used in place of an official FCG•,license. Federal Communications Commission tu Z , Wireless Telecommunications Bureau amiss 3 RADIO STATION AUTHORIZATION LICENSEE: A:T&1MQILITY SPECTRUM LLC Call Sin File Number ATTN:REGINALD YgUNGB1;COD WPZA235 AT&T MOBILITY SPECTRLIIv`fi tC Radio Service 2200 N.GREENVILLE A $f1W 'f WZ-700 MHz Lower Band(Blocks C, RICHARDSON,TX 75082 r<:?:,;• D) FCC Registration Number(FRN): 0014,9.,80726 Grant Date Effectiv'e:Date``,,y Expiration Date Print Date 12-11-2003 11-29:`111:.:2 ?` 06-13-2019 Market Number 1 hitpel Block Sub-Market Designator EAG701 R��h ";� ' n 0 Mar 0., me �NQrthea�t�,r�„, a. k'A l� 1st Build-out Date 2nd Build-out Date <` 3�rd)Build-out Date 4th Build-out Date 06-13-2019x ;; Waivers/Conditions: () K> % F�. :i'. Operation of the facilities authorized herein,are subject to the conditioh`,that,hr,ful interference may not be caused to,but must be accepted from UHF TV transmitters in Canada and Mexico as ideAtifie'dYin existing and any future agreements with those countries. If the facilities authorized herein are used to provide broadcast operations,whether,' elilsively d"fin combination with other services,the licensee must seek renewal of the license either within eight years from.the commencement of the broadcast service or within the term of the license had the broadcast service not been provide'};% ichever period is shorter in length. See 47 CFR§27.13(b). ` :,; Conditions: _ � ';' Pursuant to§309(h)of the Communications Act of 1934,as amended,47 U.S.C.§309(h), liis license'is subject to the following conditions: This license shall not vest in the licensee any right to operate the station'hor any_rtght.in the use of the frequencies designated in the license beyond the term thereof nor in any other manner than authoriither the license nor the right granted thereunder shall be assigned or otherwise transferred in violatio ,of t1reCommuttications Act of 1934,as amended. See 47 U.S.C. §310(d). This license is subject in terns to the right of use or cby §706 of the Communications Act of 1934,as amended. See 47 U.S.C. This license may not authorize operation throughout the entire geographic area or spectrum identified<on thepha dCopy;version. To view the specific geographic area and spectrum authorized by this license,refer to the Spectrum and M !Area information under the Market Tab of the license record in the Universal Licensing System(ULS). To view the license record,go to the ULS homepage at http://wireless.fcc.gov/uls/index.htm?job=home and select"License Search". Follow the instructions on how to search for license information. FCC 601-MB Page 1 of 2 April 2009 Licensee Name: AT&T MOBILITY SPECTRUM LLC Call Sign: WPZA235,, -),,a File Number: Print Date: This applicatioriis'g{aned pursuant to the Commission's Order In the Matter of Qualcomm Incorporated Petition for Declaratory�tu�ling,WaDdelcet No.05-7,FCC 06-155,released October 13,2006. k }�. Ht 43 at�' ��•`.'I^'�'�'c:fey�,.. i tl(ctr'y }'Pi i.� • r��"•vk'Gtiti�''tc� ~' 4};�r. FCC 601-MB Page 2 of 2 April 1009 e am i RF Exposure Analysis for Proposed Upgrade New Cingular Wireless PCS LLC (AT&T) Antenna Facility Site ID: LI-1025 1040 -B HORTON'S LANE, SOUTHOLD NY March 18th, 2014 Prepar d by Stephane Guillabert Senior RF Engineer Bechtel Communications,Inc. � sr New Cingular Wireless PCS, LLC(AT&T) Table of Contents 1. INTRODUCTION.................................................................................................................................3 2. SITE DATA...........................................................................................................................................3 3. RF EXPOSURE PREDICTION...........................................................................................................4 4. FCC GUIDELINES FOR EVALUATING THE ENVIRONMENTAL EFFECTS OF RF EMISSION.............................................................................................................4 5. COMPARISON WITH STANDARDS AT 6 FT ABOVE STREET LEVEL..................................5 6. CONCLUSION AT 6 FT ABOVE STREET LEVEL........................................................................5 7. FCC LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE(MPE)..........................................6 8. EXHIBIT A—INDIVIDUAL SYSTEMS POWER DENSITY BY DISTANCE AT6FT ABOVE GROUND.................................................................................................................7 9. ATTACHMENTS..................................................................................................................................9 10. FOR FURTHER INFORMATION...................................................................................................10 11. REFERENCES...................................................................................................................................10 2 New Cingular Wireless PCS, LLC(AT&T) 1. Introduction This report constitutes an RF exposure analysis in connection with the proposed New Cingular Wireless PCS, LLC (AT&T) antenna facility located at 1040 — B Horton's Lane, Southold, NY. This analysis uses site-specific engineering data to determine the predicted levels of radio frequency(RF)electromagnetic energy in the vicinity of the upgraded facility and compares those levels with the Maximum Permissible Exposure(MPE) limits established by the Federal Communications Commission. 2. Site Data AT&T Site Name: LI-1025 Number of simultaneously operating channels UMTS 1900:2-2-2 UMTS850:2-2-2 LTE700:2-2-2 LTE 1900:2-2-2 Type of antenna Andrew SBNHH-1D65A Power per channel(Watts ERP) UMTS 1900: 555 Watts UMTS850:298 Watts LTE700:260 Watts LTE1900: 838 Watts Top of Antenna(feet AGL) 72' for LTE and 62' for UMTS Antenna Aperture Length 55" 3 c- New Cingular Wireless PCS, LLC(AT&T) 3. RF Exposure Prediction The following equations established by the FCC,in conjunction with the site data,were used to determine the levels of RF electromagnetic energy present in the vicinity of the upgraded facility': 0.64*N*EIRP(9) PowerDensity = )r*R 2 (mw/cm2) Eq. 1-Farfield Where, N= Number of channels, R= distance in cm from the RC (Emission Center) of antenna, and EIRP(0) = The isotropic power expressed in milliwatts in the direction of prediction point. P lch*N*103 PowerDensity = 2* in *R*h*a l 360 (mw/cm2) Eq.2-Near-field Where Pi„/ch=Input power to antenna terminals in watts/ch,R=distance to center of emission, h=aperture height in meters, a =3 dB band-width of horizontal pattern. 4. FCC Guidelines for Evaluating the Environmental Effects of RF Emission In 1985,the FCC established rules to regulate radio frequency(RF)exposure from FCC licensed antenna facilities. In 1996, the FCC updated these rules, which were further amended in August 1997 by a Second Memorandum Opinion and Order. These new rules represent a consensus of the federal agencies responsible for the protection of public health and the environment, including the Environmental Protection Agency (EPA), the Food and Drug Administration (FDA), the National Institute for Occupational Health and Safety (NIOSH), and the Occupational Safety and Health Administration(OSHA). Under the laws that govern the delivery of wireless communications services in the United States, as amended by the Telecommunications Act of 1996, the FCC has exclusive jurisdiction over RF emissions from personal wireless antenna facilities, which include cellular, PCS, messaging and aviation sites.2 Pursuant to its authority under federal law,the FCC has established rules to regulate the safety of emissions from these facilities. 'RF exposure is measured and predicted in terms of power density in units of milliwatts(mW),a thousandth of a watt,or microwatts(ill W),a millionth of a watt,per square centimeter(cm2). Data comparing predictive analysis with on site measurements has demonstrated that power density can be effectively predicted at given locations in the vicinity of a wireless antenna facility. 2 47 U.S.C.Section 332(c)(7)(B)(iv)states that"[n]o State or local government or instrumentality thereof may regulate the placement,construction,and modification of personal wireless service facilities on the basis of the environmental effects of radio frequency emissions to the extent that such facilities comply with the Commission's regulations concerning such emissions." 4 New Cingular Wireless PCS, LLC(AT&T) 5. Comparison with Standards at 6 ft above street level The maximum cumulative power density at the facility represents 1.27%of the public/uncontrolled MPE limit.This is at 6 feet above ground and approximately 80 feet from the antenna facility. Cumulative percentage of FCC uncontrolled limit by distance. Uncontrolled MPE Result 10000 100%of Controlled Limit 100%of Uncontrolled MPE ———-5%of Uncontrolled M PE 1000 Predicted Poweroensity 100 W IL 10 0 c - 0 1 � 0 0.1 100/ 0.01 0.1 1 10 100 1000 10000 Horizontal Distance From Antenna at 6ft above ground, ft See Exhibit A for graphic breakdown of individual systems power density by distance. 6. Conclusion at 6 ft above street level This analysis requires a conservative methodology and is based on the simultaneous and continuous operation of all proposed transmitters. In actual operation,many of the transmitters will operate intermittently and therefore the actual levels will be even lower. This analysis shows that the maximum power density in accessible areas at this location is well below the Maximum Permissible Exposure limit established by the FCC. 5 New Cingular Wireless PCS, LLC(AT&T) 7. FCC Limits for Maximum Permissible Exposure (MPE) Power Density (MW" 100 Occupatimal `s --------- General Public, •5 5.0 (� 5 �k 55 t 5 ----------- R5 e PI 5� >f y l+ 5 / 0.2 `�----------- 14 1 I 1 ! 1 1 va 4.8 1.34 3.4 30 300 1,500 100,000 Frequency(Wz) 6 New Cingular Wireless PCS, LLC(AT&T) 8. Exhibit A—individual systems power density by distance at 6ft above ground ATT LTET00 10000 1000 100 N E U 10 3 m 1 0 m 0 0.1 a 001 0-001 - 0.1 1 10 100 1000 10000 Horizontal Distance From Antenna at 6ft above ground,ft ATT LTE1900 10000 1000 100 E 10 U 3 1 2�Z m 0.1 m 0 0.01 a- 0.001 0.001 0.0001 0.00001 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna at 6ft above ground, ft 7 New Cingular Wireless PCS, LLC(AT&T) ATT UMTS1900 10000 1000 100 E 10 _U 1 0 0.1 m 0 0-01 d 0.001 0-0001 0.00001 0-1 1 10 100 1000 10000 Horizontal Distance from Antenna at 6ft above ground, ft ATT UMTS850 10000 1000 100 E 10 U 1 3 c 0.1 (D 0 0.01 IL 0.001 0.0001 0-00001 0.000001 0-1 1 10 100 1000 10000 Horizontal Distance fromAntenna at 6ft above ground, ft 8 New Cingular Wireless PCS, LLC(AT&T) 9. Attachments ATTACHMENT A - LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE(MPE) (A) Limits for Occupational/Controlled Exposure Frequency Electric Field Magnetic Field Power Density Averaging Time Range Strength (E) Strength (H) (S) 1E12, IH12 or S (MHz) (V/m) (o/m) (mw/cm2) (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f2)* 6 30-300 61.4 0.163 1.0 6 300-1500 — -- f/300 6 1500.100,000 -- -- 5 6 (B) Limits for General Population/Uncontrolled Exposure Frequency Electric Field Magnetic Field Power Density Averaging Time Range Strength (E) Strength (H) (S) 1E12, IH12 or S (MHz) (V/m) (A/m) (MVI/CM2) (minutes) 0.3.1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f2)* 30 30-300 27.5 0.073 0.2 30 300-1500 -- -- f/1500 30 1500-100,000 -. -- 1.0 30 f= frequency in MHz*Plane-%%ave equivalent power density NOTE 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided he or she is mac aware of the potential for exposure. NOTE 2: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or Gan not exercise control over their exposure. 9 New Cingular Wireless PCS, LLC(AT&T) ATTACHMENT B INFORMATION I INFORMATION 1 INFORMACION�j The signs must be posted in a visible area at each entrance to the site and at •- localized areas. j ACAUTION signs alert persons that they are attempting to enter an area in which RF exposure may exceed the Occupational/Controlled MPE. r The signs must be posted in a visible area at each entrance to the site and at localized areas (in conjunction with any required barriers) when the RFE survey indicates that exposure levels in any area of the rooftop are equal to or exceed the On t61s tower: R.db^eq.enoy0eklseemsoro Occupational - Controlled MPE. antenna.1y oaaeod FCC rules for�urnan eaposuro. n.wMa mmenww.o,....—d a imMer a a�e...a.ay.aer.w w 10. For Further Information Additional information about the environmental impact of RF energy from personal wireless antenna facilities can be obtained from the Federal Communications Commission: Dr.Robert Cleveland Federal Communications Commission Office of Engineering and Technology Washington,DC 20554 RF Safety Program: 202-418-2464 Internet address: rfsafety@fcc.gov RF Safety Web Site: www.fcc.gov/oet/rfsafety 11. References [1] The Communications Act of 1934,as amended by the Telecommunications Act of 1996,47 U.S.C. Section 332(c)(7)(B)(iv). [2] Guidelines for Evaluating the Environmental Effects of Radio frequency Radiation,Notice of Proposed Rulemaking,ET Docket 93-62, 8 FCC Rcd 2849(1993). [3] Guidelines for Evaluating the Environmental Effects of Radio frequency Radiation,Report and Order,ET Docket 93-62,FCC 96-326,adopted August 1, 1996. 61 Federal Register 41006(1996). [4] Guidelines for Evaluating the Environmental Effects of Radio frequency Radiation,Second Memorandum Opinion and Order,ET Docket 93-62,adopted August 25, 1997. [5] Evaluating Compliance with FCC Guidelines for Human Exposure to Radio frequency Electromagnetic Fields,OET Bulletin 65,August, 1997. 10 valmontT STRUCTURES VALMONT MICROFLECT 3575 25th St. SE Salem, OR 97302 PHONE: 1-800-547-2151 ENGINEER: Nathan Ross Reviewed by: COMMUNICATION POLE DESIGN CALCULATIONS OF NEAM 0 by y � w F 0 KMB DESIGN VALMONT ORDER# 279218 FEB 03 2017 .SITE NAME: SOUTHOLD, NY POLE HEIGHT: 34FT (95 FT AGL) %lal on' t Page 1 STRUCTURES 1/30/17 ENGINEERING DATA for KMB DESIGN SOUTHOLD,NY VALMONT QUOTATION 279218 1) STRUCTURE DESIGN CONFORMS TO EIA/TIA-222-G INCLUDING: 105.0 MPH WIND(3 SECOND GUST,50 YR.RETURN PERIOD) 50.0 MPH ICE WIND(50 YR.RETURN PERIOD) DESIGN ICE THICKNESS=0.75 INCHES EXPOSURE CATEGORY C STRUCTURE CLASSIFICATION If TOPOGRAPHIC CATEGORY 1 60.0 MPH BASIC WIND SPEED WITH NO ICE FOR TWIST AND SWAY 2) FEEDLINES ARE ASSUMED TO BE PLACED INTERIOR TO THE POLE. 3) ALL MICROWAVE ASSUMED TO BE 6 GHz UNLESS OTHERWISE NOTED. 4) TOTAL POLE HEIGHT IS 35 FT AGL 5) (6)48 IN X 10 FT CANISTERS TO 95 FT AGL 6) ELEVATIONS ARE MEASURED FROM TOP OF BASE PLATE(APPROX 1 FT AGL) 7) POLE DESIGNED TO 135 MPH ULTIMATE WIND SPEED PER IBC 2012 8) WIND SPEED CONVERSION TO 105 MPH NOMINAL PER IBC 2012 1609.3.1 9) LOADING AS FOLLOWS: 34.0'POLE 1-48"DIA X 60'CELL SILO @ 34.0 STRUCTURE ANCHORAGE INFORMATION POLE HEIGHT(FT): 34 NUMBER OF A.B.'s: 8 BOLT CIRCLE(IN): 54.50 DIA.OF A.B.'s(IN): 1.75 BASE VERTICAL(K): 22.00 LENGTH OF A.B.'s(IN): 66.00 BASE SHEAR(K): 11.77 PROJECTION LENGTH(IN): 8.75 BASE MOMENT(FT-K): 630 TEMPLATE OD(IN): 58.00 ,/almost - Structures Engineering Form#3098(12105) Page 2 val ont T STRUCTURES BY DATE CHKD.BY DATE SHEET NO. 1/30/17 ENGINEERING DATA for KMB DESIGN SOUTHOLD, NY VALMONT QUOTATION 279218 EIA/TIA-222-G BASIC WIND: 105.0 MPH DESIGN ICE THICKNESS: 0.75 IN. WIND&ICE: 50.0 MPH EXPOSURE CATEGORY: C TWIST&SWAY: 60.0 MPH STRUCTURE CLASS.: II Ss: N/A TOPOGRAPHIC CATEGORY: 1 Sl: N/A DATA W.O.ICE DATA W/ICE QTY DESCRIPTION HEIGHT EPA WT EPA WT 1 48"DIA X 60'CELL SILO @ 34.0' 144.00 12000 225.00 24000 f Valmont - Structures EnaineeForm#3098(12/05) BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 *** SUMMARY *** Design Code: TIA-222-G Addendum 2 ---------------------------------------------------- DESIGN SUMMARY ------------------------------ ---------------------- Height Above Base Plate (ft) 34.00 Ground Line Diameter (in) 48.000 Pole Shaft Weight (lbs) 5472 Top Diameter (in) 48.000 Pole Taper (in/ft) 0.00000 Shape: 16 Sides Section Characteristics /First/ Base Diameter (in) 48.000 Top Diameter (in) 48.000 Thickness (in) 0.31250 Length (ft) 34.000 Weight (lbs) 5472 Yield Strength (ksi) 65.00 ------------------------------------------- ANALYSIS SUMMARY ------------------------------------------- Pt. of Governing Pole Fixity Level Sec.l Top Governing Load Case WIND WIND WIND Height (ft) 0.00 0.00 34.00 Resultant Moment (in-kips) 7562 7562 3481 Shear Force (lbs) 11774 11774 8078 Axial Force (lbs) 20976 20976 14356 Effective Yield Strength (ksi) 71.62 71.62 71.62 Combined Interaction Value 0.22 0.22 0.10 Total Deflection (in) 0.00 0.00 1.28 Note: Diameters are outside, measured across the flats Forces and moments are reported in the local element coordinate system BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 *** POLE SHAFT POINT OF FIXITY REACTIONS *** Loading Moments Moments Moments Moments Shear Shear Shear Notes Case About About Resultant Vertical In In Resultant Identifier X-Axis Y-Axis (X & Y) Torsional Force X-Direction Y-Direction (X & Y) (in-kips) (in-kips) (in-kips) (in-kips) (lbs) (lbs) (lbs) (lbs) WIND 5793 -4861 7562 0 20979 7565 9015 11769 ICE + WIND 1326 -1113 1732 0 38108 1809 2156 2814 T+S 1056 -886 1379 0 17473 1381 1646 2149 Note: Positive vertical force is downward. Reactions are considered in the global coordinate system. BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 *** INPUT LOADS *** Design Code TIA-222-G Addendum 2 Loading Case WIND Orientation of System Basic Wind Velocity is 105.00 mph Ice Thickness 0.00 +******* +X-Axis Wind Orientation is 50.0 Degrees Clockwise From +X Axis * * . (Transverse) Structure Weight Overload Factor is 1.200 Exposure C, Gust Factor 1.10 Structure Category 2, Topographic Category 1, Crest Height.0.00 ft (Longitudinal) * * (Vertical) Orientations are Measured Clockwise From +X Axis +Y-Axis * * +Z-Axis Positive Y Axis is 90 Degrees Clockwise From +X Axis Foundation Rotation of 0.00 Degrees Elevation of structure base above surrounding terrain = 1.00 ft Load Mounting Load Load Orientation Number Height Height Eccentricity in XY Plane Force-X Force-Y Force-Z EPA (ft) (ft) (ft) (Degrees) (lbs) (lbs) (lbs) (ft^2) 1 34.00 69.90 0.00 50.00 5142 6128 14400 144.00 1-48" DIA X 6 BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 *** INPUT LOADS *** Design Code TIA-222-G Addendum 2 Loading Case ICE + WIND Orientation of System Basic Wind Velocity is 50.00 mph Ice Thickness 0.75 +******* +X-Axis Wind Orientation is 50.0 Degrees Clockwise From +X Axis * * (Transverse) Structure Weight Overload Factor is 1.200 Exposure C, Gust Factor 1.10 Structure Category 2, Topographic Category 1, Crest Height 0.00 ft (Longitudinal) * * (Vertical) Orientations are Measured Clockwise From +X Axis +Y-Axis * * +Z-Axis Positive Y Axis is 90 Degrees Clockwise From +X Axis Foundation Rotation of 0.00 Degrees Elevation of structure base above surrounding terrain = 1.00 ft Load Mounting Load Load Orientation Number Height Height Eccentricity in XY Plane Force-X Force-Y Force-Z EPA (ft) (ft) (ft) (Degrees) (lbs) (lbs) (lbs) (ft^2) 1 34.00 69.90 0.00 50.00 1139 1357 28800 225.00 1-48" DIA X 6 BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 *** INPUT LOADS *** Design Code TIA-222-G Addendum 2 Loading Case T+S Orientation of System Basic Wind Velocity is 60.00 mph Ice Thickness 0.00 +******* +X-Axis Wind Orientation is 50.0 Degrees Clockwise From +X Axis * * (Transverse) Structure Weight Overload Factor is 1.000 Exposure C, Gust Factor 1.10 Structure Category 2, Topographic Category 1, Crest Height 0.00 ft (Longitudinal) * * (Vertical) Orientations are Measured Clockwise From +X Axis +Y-Axis * * +Z-Axis Positive Y Axis is 90 Degrees Clockwise From +X Axis Foundation Rotation of 0.00 Degrees Elevation of structure base above surrounding terrain = 1.00 ft Load Mounting Load Load Orientation Number Height Height Eccentricity in XY Plane Force-X Force-Y Force-Z EPA (ft) (ft) (ft) (Degrees) (lbs) (lbs) (lbs) (ft-2) 1 34.00 69.90 0.00 50.00 939 1119 12000 144.00 1-48" DIA X 6 BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 *** Properties *** Distance Diameter From Across Wall D/t W/t Moments of Connection Base Flats Thickness Across Across Inertia Area Locations (ft) (in) (in) Flats Flats (in^4) (in^2) Top of Sect 1 34.00 48.000 0.3125 153.60 25.32 13585 47.30 31.50 48.000 0.3125 153.60 25.32 13585 47.30 29.00 48.000 0.3125 153.60 25.32 13585 47.30 26.50 48.000 0.3125 153.60 25.32 13585 47.30 24.00 48.000 0.3125 153.60 25.32 13585 47.30 21.50 48.000 0.3125 153.60 25.32 13585 47.30 19.00 48.000 0.3125 153.60 25.32 13585 47.30 16.50 48.000 0.3125 153.60 25.32 13585 47.30 14.00 48.000 0.3125 153.60 25.32 13585 47.30 11.50 48.000 0.3125 153.60 25.32 13585 47.30 9.00 48.000 0.3125 153.60 25.32 13585 47.30 6.50 48.000 0.3125 153.60 25.32 13585 47.30 4.00 48.000 0.3125 153.60 25.32 13585 47.30 2.00 48.000 0.3125 153.60 25.32 13585 47.30 Pt of Fixity 0.00 48.000 0.3125 153.60 25.32 13585 47.30 BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 Forces and Moments for Pole in the Local Element Coordinate System Loading Case WIND Dist. From Resultant Shear Shear Resultant Base Mx My Mx & My Torsion X-Dir. Y-Dir. Shear Axial (ft) (in-kips) (in-kips) (in-kips) (in-kips) (lbs) (lbs) (lbs) (lbs) 34.00 2667 -2237 3481 0 5193 6188 8078 14356 31.50 2856 -2396 3728 0 5390 6424 8385 14841 29.00 3052 -2561 3984 0 5584 6655 8687 15327 26.50 3255 -2731 4249 0 5774 6881 8983 15813 24.00 3465 -2907 4523 0 5960 7103 9273 16299 21.50 3681 -3089 4806 0 6142 7320 9555 16785 19.00 3904 -3276 5097 0 6319 7531 9831 17272 16.50 4133 -3468 5396 0 6491 7735 10098 17759 14.00 4368 -3665 5702 0 6657 7933 10356 18246 11.50 4609 -3868 6017 0 6820 8127 10610 18734 9.00 4856 -4075 6339 0 6982 8321 10862 19222 6.50 5109 -4287 6669 0 7144 8513 11114 19710 4.00 5367 -4504 7006 0 7305 8706 11365 20198 2.00 5578 -4681 7282 0 7434 8859 11565 20590 0.00 5793 -4861 7562 0 7568 9019 11774 20976 BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 Deflections and Stresses for Pole Loading Case WIND *** Deflections and Stresses *** Distance Defl. Axial Flexural Shear Torsion Combined Effective From Defl. Defl. Resultant Defl. Interaction Interaction Interaction Interaction Stress Yield Base X-Dir Y-Dir X & Y Z-Dir Rotation Term Term Term Term Interaction Strength (ft) (in) (in) (in) (in) (deg.) (ksi) 34.00 0.8 1.0 1.3 0.0 0.32 0.00 0.10 0.01 0.00 0.10 71.62 31.50 0.7 0.9 1.1 0.0 0.30 0.01 0.10 0.01 0.00 0.11 71.62 29.00 0.6 0.7 1.0 0.0 0.29 0.01 0.11 0.01 0.00 0.12 71.62 26.50 0.5 0.6 0.8 0.0 0.27 0.01 0.12 0.01 0.00 0.12 71.62 24.00 0.4 0.5 0.7 0.0 0.25 0.01 0.13 0.01 0.00 0.13 71.62 21.50 0.4 0.4 0.6 0.0 0.23 0.01 0.13 0.01 0.00 0.14 71.62 19.00 0.3 0.3 0.4 0.0 0.21 0.01 0.14 0.01 0.00 0.15 71.62 16.50 0.2 0.3 0.3 0.0 0.1.9 0.01 0.15 0.01 0.00 0.16 71.62 14.00 0.2 0.2 0.2 0.0 0.16 0.01 0.16 0.02 0.00 0.17 71.62 11.50 0.1 0.1 0.2 0.0 . 0.14 0.01 0.17 0.02 0.00 0.17 71.62 9.00 0.1 0.1 0.1 0.0 0.11 0.01 0.18 0.02 0.00 0.18 71.62 6.50 0.0 0.0 0.1 0.0 0.08 0.01 0.19 0.02 0.00 0.19 71.62 4.00 0.0 0.0 0.0 0.0 0.05 0.01 0.20 0.02 0.00 0.20 71.62 2.00 0.0 0.0 0.0 0.0 0.03 0.01 0.20 0.02 0.00 0.21 71.62 0.00 0.0 0.0 0.0 0.0 0.00 0.01 0.21 0.02 0.00 0.22 71.62 BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 Forces and Moments for Pole in the Local Element Coordinate System Loading Case ICE + WIND Dist. From Resultant Shear Shear Resultant Base Mx My Mx & My Torsion X-Dir. Y-Dir. Shear Axial (ft) (in-kips) (in-kips) (in-kips) (in-kips) (lbs) (lbs) (lbs) (lbs) 34.00 597 -501 779 0 1162 1384 1807 28798 31.50 639 -536 834 0 1216 1449 1892 29501 29.00 684 -574 892 0 1270 1513 1975 30203 26.50 730 -613 953 0 1322 1575 2057 30903 24.00 778 -653 1016 0 1373 1636 2136 31601 21.50 828 -695 1081 0 1423 1696 2214 32297 19.00 880 -738 1149 0 1471 1754 2289 32990 16.50 933 -783 1219 0 1518 1809 2362 33680 14.00 989 -830 1290 0 1564 1863 2432 34368 11.50 1045 -877 1365 0 1608 1916 2501 35052 9.00 1104 -926 1441 0 1652 1969 2570 35731 6.50 1164 -976 1519 0 1695 2021 2638 36405 4.00 1225 -1028 1599 0 1739 2073 2706 37072 2.00 1275 -1070 1665 0 1774 2114 2759 37597 0.00 1326 -1113 1732 0 1810 2157 2816 38108 BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 Deflections and Stresses for Pole Loading Case ICE + WIND *** Deflections and Stresses *** Distance Defl. Axial Flexural Shear Torsion Combined Effective From Defl. Defl. Resultant Defl. Interaction Interaction Interaction Interaction Stress Yield Base X-Dir Y-Dir X & Y Z-Dir Rotation Term Term Term Term Interaction Strength (ft) (in) (in) (in) (in) (deg.) (ksi) 34.00 0.2 0.2 0.3 0.0 0.07 0.01 0.02 0.00 0.00 0.03 71.62 31.50 0.2 0.2 0.3 0.0 0.07 0.01 0.02 0.00 0.00 0.03 71.62 29.00 0.1 0.2 0.2 0.0 0.07 0.01 0.02 0.00 0.00 0.04 71.-62 26.50 0.1 0.1 0.2 0.0 0.06 0.01 0.03 0.00 0.00 0.04 71.62 24.00 0.1 0.1 0.2 0.0 0.06 0.01 0.03 0.00 0.00 0.04 71.62 21.50 0.1 0.1 0.1 0.0 0.05 0.01 0.03 0.00 0.00 0.04 71.62 19.00 0.1 0.1 0.1 0.0 0.05 0.01 0.03 0.00 0.00 0.04 71.62 16.50 0.0 0.1 0.1 0.0 0.04 0.01 0.03 0.00 0.00 0.05 71.62 14.00 0.0 0.0 0.1 0.0 0.04 0.01 0.04 0.00 0.00 0.05 71.62 11.50 0.0 0.0 0.0 0.0 0.03 0.01 0.04 0.00 0.00 0.05 71.62 9.00 0.0 0.0 0.0 0.0 0.02 0.01 0.04 0.00 0.00 0.05 71.62 6.50 0.0 0.0 0.0 0.0 0.02 0.01 0.04 0.00 0.00 0.05 71.62 4.00 0.0 0.0 0.0 0.0 0.01 0.01 0.04 0.00 0.00 0.06 71.62 2.00 0.0 0.0 0.0 0.0 0.01 0.01 0.05 0.00 0.00 0.06 71.62 0.00 0.0 0.0 0.0 0.0 0.00 0.01 0.05 0.00 0.00 0.06 71.62 BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Forces and Moments for Pole in the Local Element Coordinate System Fuse 1.13.0.0 Loading Case T+S Dist. From Resultant Shear Shear Resultant Base Mx My Mx & My Torsion X-Dir. Y-Dir. Shear Axial (ft) (in-kips) (in-kips) (in-kips) (in-kips) (lbs) (lbs) (lbs) (lbs) 34.00 486 -408 635 0 947 1128 1473 11999 31.50 521 -437 680 0 983 1171 1529 12401 29.00 556 -467 726 0 1018 1213 1584 12803 26.50 593 -498 775 0 1053 1255 1638 13206 24.00 632 -530 825 0 1087 1295 1691 13608 21.50 671 -563 876 0 1120 1335 1743 14011 19.00 712 -597 929 0 1153 1374 1793 14413 16.50 754 -632 984 0 1184 1411 1842 14816 14.00 796 -668 1040 0 1215 1448 1890 15218 11.50 840 -705 1097 0 1244 1483 1936 15621 9.00 885 -743 1156 0 1274 1519 1982 16023 6.50 932 -782 1216 0 1304 1554 2029 16426 4.00 979 -821 1278 0 1334 1589 2075 16829 2.00 1017 -854 1328 0 1357 1618 2112 17151 0.00 1056 -886 1379 0 1382 1647 2150 17472 BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 Deflections and Stresses for Pole Loading Case T+S *** Deflections and Stresses *** Distance Defl. Axial Flexural Shear Torsion Combined Effective From Defl. Defl. Resultant Defl. Interaction Interaction Interaction Interaction Stress Yield Base X-Dir Y-Dir X & Y Z-Dir Rotation Term Term Term Term Interaction Strength (ft) (in) (in) (in) (in) (deg.) (ksi) 34.00 0.2 0.2 0.2 0.0 0.06 0.00 0.02 0.00 0.00 0.02 71.62 31.50 0.1 0.2 0.2 0.0 0.06 0.00 0.02 0.00 0.00 0.02 71.62 29.00 0.1 0.1 0.2 0.0 0.05 0.00 0.02 0.00 0.00 0.02 71.62 26.50 0.1 0.1 0.1 0.0 0.05 0.00 0.02 0.00 0.00 0.03 71.62 24.00 0.1 0.1 0.1 0.0 0.05 0.00 0.02 0.00 0.00 0.03 71.62 21.50 0.1 0.1 0.1 0.0 0.04 0.00 0.02 0.00 0.00 0.03 71.62 19.00 0.1 0.1 0.1 0.0 0.04 0.01 0.03 0.00 0.00 0.03 71.62 16.50 0.0 0.0 0.1 0.0 0.03 0.01 0.03 0.00 0.00 0.03 71.62 14.00 0.0 0.0 0.0 0.0 0.03 0.01 0.03 0.00 0.00 0.03 71.62 11.50 0.0 0.0 0.0 0.0 0.02 0.01 0.03 0.00 0.00 0.04 71.62 9.00 0.0 0.0 0.0 0.0 0.02 0.01 0.03 0.00 0.00 0.04 71.62 6.50 0.0 0.0 0.0 0.0 0.01 0.01 0.03 0.00 0.00 0.04 71.62 4.00 0.0 0.0 0.0 0.0 0.01 0.01 0.04 0.00 0.00 0.04 71.62 2.00 0.0 0.0 0.0 0.0 0.00 0.01 0.04 0.00 0.00 0.04 71.62 0.00 0.0 0.0 0.0 0.0 0.00 0.01 0.04 0.00 0.00 0.04 71.62 MINIMUM DEFLECTION RATIO // DEFLECTION LIMIT / DEFLECTION // IS BY VALMONT INDUSTRIES FOR: KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 DATE 01/30/2017 Fuse 1.13.0.0 NUMBER SHIPPED PROJECTION GALVANIZED THREAD OF BOLTS DIAMETER LENGTH WEIGHT AS LENGTH LENGTH SIZE (IN.) (IN.) (KIPS) (IN.) (IN.) 8 1.750 66.00 0.51 BOLTS, TEMPLATES 8.75 66.00 5-UNC-2A STEEL STEEL MAXIMUM BOLT MAXIMUM BOLT FACTORED NOMINAL STRESS INTERACTION CONFIGURATION OF SPEC. SPECIF. FORCE SHEAR FORCE TENS. STRENGTH AREA VALUE BOTTOM END VALMONT (KIPS) (KIPS) (KIPS) (SQ. IN.) S23 A615 59.96 1.47 152.00 1.90 0.41 THREADED WITH HEAVY HEX HEAD NUT NOTE: BOLT INTERACTION VALUE WAS CALCULATED BY DIVIDING SHEAR FORCE BY FACTOR RELATED TO DETAIL TYPE d] IN EIA-G SPECS. *** BOLT COORDINATES (IN.) *** BOLT NO. X-COORD Y-COORD * BOLT NO. X-COORD Y-COORD 1 27.250 0.000 * 2 19.269 19.269 3 0.000 27.250 MAX. BOLT CIRCLE = 54.50 IN. TEMPLATE DIAMETER = 58.00 IN. *** BASE PLATE CHARACTERISTICS GOVERNED BY LOADING CASE WIND *** BASE PLATE BASE PLATE ACTUAL RAW MATERIAL POLE DIAM. DIAMETER THICKNESS WEIGHT WEIGHT (MAJOR (IN.) (IN.) (KIPS) (KIPS) (DAM.) N ; 59.78 1.75 1.02 1.75 48.00 EFFECTIVE PLASTIC MOMENT IN PLASTIC FACTORED PLATE WIDTH SECTION MOD. BASE PLATE MOMENT RESISTING MOM. (IN.) (CU. IN.) (IN. -K) (IN. -K) (IN. -K) 18.85 14.43 194.87 721.58 649.43 STEEL STEEL EFFECTIVE STRESS SPECIF. SPECIF. YIELD STRESS RATIO VALMONT OTHER (KSI) S56 A572 50 0.30 ** LOADS AT POLE BASE IN THE GLOBAL COORDINATE SYSTEM ************************** LOADING CASES ************************* LOADING CASE IDENTIFICATION WIND ICE + WIND T+S ]MAX CRITERION- LOAD CASE MOMENT ABT. X-AXIS (IN-KIP) 5792 1326 1056 ]MOMENT ABT. X WIND MOMENT ABT. Y-AXIS (IN-KIP) -4860 -1113 -886 ]MOMENT ABT. Y WIND SHEAR FORCE (LB.) 11768 2814 2148 ]RES. MOMENT WIND VERTICAL FORCE (LB.) 20978 38108 17472 ]SHEAR FORCE WIND ]BOLT FORCE WIND ]BOLT TENSION WIND Quote/Order No.: ;72782181 ENGR`NAR' ,•�; '^ `� Total flagpole height= Date: 113012017 48"4 Heightofpole= 95 ft Silo pipe change height= "-_ -=5G ft Diameter of cellsllo Height of cellsllo= 60 ft Flag dimensions= ..x.;.a.. 3-seegust windspeed=V=z'`_v��;;�;..-.105'.mPh #of Top Whip Antennas_ -1`=';- =0f default 0 #of Antennas=::'-_;':_ '.",961 default#of Carders•3 55 ft #of Carriers= '_r,;. _ �:.i,8� 60 ft PalntType.`.;-�.`.E_;,;Whk61 default Gray Weight= 12.00 k Topp- .`''.i.?=• 'i."=1.i default Topo H Exposure= `-'` ;,-.c.0 OK default c Structure Class=;-.'=: "?„s_;`,,:2OK defaultl _ W Indarea of silo=CA�= 144.0 ft' - 35 ft Windarea of flag=CAAA= 0.0 W W Indpressure per EIA-G= 36.9 psf Force from lop part of silo= 5.67 k Force from entire silo= 8.51 k Force from flag= 0.00 k Ay =PLs/3EI= 34.8 In Moment at pipe change= 1779.0 In-k =148.3 ft-k Moment at base of silo- 3480.6 In-k =290.1 ft-k Silo upper support pipe: a=�**,PIpeY$(ze�,14,z037ffi`�;c; �.SIlO•support pipe= 14"OD x 0.375"Wall Thickness Support pipe weight per foot= 54.62lbsift Z= 69.63 Ins fb=M/Z= 25.55,,x'4 ,I4.9'50kst,OK Pipe to pipe weld size=;? :51n = 72.84 in' Weld stress= 24.42 b11C k 1-0.750.6'70ksi,OK Bolts for pipe to pipe flange: bolt diameter= In area of bolt= 1.325 Int number afbolts= siloflange: Flange Max bolt force = .4. s;;;•.„.=_,;.42.4 I �In k _ Max bolt stress= 32.0;ksl a�78.75ks1=0.75.105ksl,OK Q ? 7 in Silo pipe to pipe flange: + Moment in sllo flange- 275.3239321 In-k Fb= 50 ksl trequired=: 1.87 in >;i:O,In re"d,OK Bolts for base flange: bolt diameter=_.``,j =�:'x:,»1:6?In area of bolt= 1.325 In' number of bolts= 6 Flange bolt circle= 42 In Max batt force= - 55.2 k silo flange: Max boll stress= 0.75'105ks1,OK 11.5 In Silo base flange: O ? 71n Moment in silo flange= 635.3527015 In-k +_ Fb= 50 ksl t,,= 2.84 In t= £i".,xsas 325;M>-,, ,In req'd,OK Silo lower support PIPs: No.of Spokes=8 PIPe- 18"%437S'�'--=-. Silo support pipe= 18"OD x 0.375"Wall Thickness Support pipe weight per foot= 70.65 lbs/ft Z= 116.51 Ins 1= 1048.57 in fb=NZ= 30 a 45ks1e0.9.50ksl,OK tapered pole Range: Pipe to flange weld size In 3 in 150.31 In Weld stress= 23.2 i°'31'Asla0,75•0.6'7oksi,OK 7 In Tapered pole flange: O Moment In pale flange= 165.744183 In-k Fb= 50 ksl t,q„m= 1.45 in tapered Pole weld: t=-•w._,='; ;;<<j.75,In S-i1.0In req'd,OK 7 _�nl Flange to pole weld sizeIn 0 0.5 In Total weld= 87 In 1.25 in zaa= 177.19 In' 2.5 in Weld stress= 19.6'a31.5ksI-0.75.0.W0ks1,OK valmont MICROFLECT VALMONT/MICROFLECT 3575 25' ST. SE- P.O. BOX 12985 SALEM, OR 97302-1190 PHONE: 1-800-547-2151 ENGINEER: NAR Reviewed by: NAR DRILLED PIER FOUNDATION DESIGN CALCULATIONS of NEw y c RD �� FEB 0 3 2017 Valmont Order No.: 279218 Customer: KMB DESIGN Site: SOUTHOLD Pole Ht: 34 FT (95 FT AGL) valmont;Y Monopole Pier Design Lateral Pressure CUSTOMER:ifEMB`DESIG,�(w� , 'GREG SITE:SOUTuOLD+ ° ax,t.k4" s ha4 .";l K UNIT WEIGHT BELOW THE WATER TABLE. "5 +.,: .l .2.a.« �u..:3.::;s.�..7.t.a t^,y K' �3;k�„,Yfr,.W;r DWG NO.!B=a45362,��`-; � 105 w---'�EIA-F=2(Default),TIA-G=1 0 FACTOR>t _ 075:i=u w EIA-F=1,TIA-G=0.75 GW DEPTH(FT) 38.7 BGS ultimate lateral pressure=yztan'(45+(0/2))+2ctan(45+(0/2)) (ref.Bowles,eq.2-41) allow.Lat.Pressure=(ult.Lat.Pressure)/FS Group Soil Type Depth start ftDepth and(ft) c(psf) 4(degrees) y(pcf) lateral pressure start psf) lateral pressure end psf) slope(psflft) .,;.��,•�„--..-------------_._-_�'�::...,....:._.....�,....�_ � _ `� � �.�r� '�" ----------- --------- -- ------- -- -- 304.44 11 0.00 11568_69 P S=s 380 0.83 •g:�:iy.:.:: ""f1.:y:,. �:.e ".��%i: ..°„':i §,.,....,. ;..�.;_,� ,"u �... �, _.r, 2 .,, 'S�";• :x:10203.13.•:• :.T— .117.73.;15;. .13 <• . ..:�zc"^=.. r� a , r I s i-- i 4 Americas Lighting and Communication Structures Valmont Industries,Inc.7002 North 288th Street,Valley,NE 68064-0358 USA Toll Free:800-825-6668 Fax:402-359-6091 www.valmont.com Pole Geometry Bolt Circle = 54.50 Inches # of Bolts = 8.0 Bolt Diameter = 1.75 Inches Bolt Projection = 8.8 Inches Bolt Length = 66.0 Inches Base Plate Diameter = 58.0 Inches Pole Loads • Factored Moment = 630.1 ft-Kips Factored Shear = 11.8 Kips ' Factored Weight = 22.0 Kips ---_.___. Shear Height = 53.5 Ft Moment Anchor Bolt Allowables Fu = 100.0 Ksi • 6 FY = 75.0 Ksi At = 1.90 in^2 Anchor Bolt Loads Moment = 7561.8 in-Kips Shear - 11.8 Kips Weight = 22.0 Kips Calculate the Bolt Maximum Applied Force Bolt Applied Force = 24943.8 in-Kips + 11.8 / 0.50 Kips + 22.0 kips = 62.9 Kips 54.5 in * 8 8 8.0 Bolt Allowable = .8 * Fu * At 152.0 Kips (per EIA-G Sec. 4.9.9) Bolt Allowable > Bolt Applied Force , 152 Kips > 62.9 Kips => OK Calculate the Anchor Bolt Development Length ACI 318 ld = db*Fy*apyX* 3 (40*(fc')^.5) * ((c+Ktr)/db)) Given all minimums are met for the Bar Installation Per ACI a = 1 P = 1 � = 1 ((c+Ktr)/db) 1.5 Id 1.75*75000* 3 = 104 in (40-(4000(^.5(•1.5 Calculate the Ultimate Bond Stress Fy*Ag/(a*db*ld) = Bond-Allowable Ksi 0.250 Ksi Calculate the Allowable Bond Stress .6*Bond Allow*1.33 = 0.199 Ksi Calculate the Required Bolt Length Lre Bolt Applied Force + Bolt Projection = 66.1 in >66 in provided, bottom template q 3,14•db*0.199 needs to be double nutted Check AB pullout via Rebar Development length with bottom template double nutted: ((c+Ktr)/db)rebar= 2.5 Ldb = (3*db*fy/(40*f'c^0.5*((c+Ktr)/db)))*(As_req/As_prov'd) - 14.8 in L_regd = Ldb + abproj + 3.6875" + 3" = 30.2 in Bolt Length > Bolt Required Length 66 in 1 30.2 in => OK ACER PROJECT NO. 20150006 DATED 05/08/2D15 Re(:ACI 31R BUILDING CD DE RE4uI0.EHEN}5 valmont By: NAR DRILLED PIER ANALYSIS site: SOUTHOLD check: NAR MLE ST-URE VICRVCLCCT Dwg: B-145362 A-279218 Data: 01/30/17 CUSTOMER:IQ10 DE9IGN Calculate the Concrete Shear Strength 11.8 Kips ACI 318 Shear Height =53.5' VG = 2*(fc')D.s*bw*d Given: 0 bw = 72 in SECTION AT 3.6 3.6 THE MAX d = 56.1 in - MOMENT IN THE fes' = 4000 in 5 PIER = 0.85 MAX PRESSURE 4375 PSE kVG - 434 Kips 10 Calculate the Reinforament Shear Strength 14.4 SECTION AT Act Gla #4 heri—tal cies at 12L apacin_ 15 14.4 THE MAX SHEAR IN THE Vs = s y* PIER Given: 20 MAX NEGATIVE A� = 0.4 in^2 PRESSURE 6089 PSF fy = 60 ksi 25 d = 4.676 Ft FT s = 1 Ft Pressure Profile 0.85 for kVs = 127 Kips Anaiysis The *'=v*'^^'^ Shear in the Pier occurs at Reaction Inflection Point 14.4' Load Factors for the design Acx 318 EE 2-D atm mm_a aIe[adore4 by 1.6 611-dy UAc1 = 1.0 USIA = 1.0 UTOTAL - UCIA*UAGI UTOTAL = 1.0 Vdssign-UTOTAL*V— = 176.7 Kips ov. f OV, > Vdbeign 434.3 Kips t 127.2 Kips - 561.5 Kips > 176.7 Kips =>ox The maximim bending stress in the pier occurs at 3.6' below the ground level. Where the (passive pressure reaction) _ (the applied shear) Depth MmE� - Passive P(essun: M,m = 8139.4 At The Location ft dft=Applied Shear 'Ground-Lina Use only the steel to carry the banding loads - Calculate the Reinforcment Bending Strength Use (221 #9 vertical —her. Vertical Rebar Section Properties I = AsIEEL*RvB 2 in^4 2 A.,,,, = 22 in^2 R— = 30.9 in I - 10527.4 in^4 S = 340.3 in^3 Base the bending strength on factored Vertical bar Fy per TIA-222-G of 54 Kai FTy = 60 KSI 0 = 0.9 FTyA:.w m- = FT1*� FTMABLE = 54 KSI Max Design Moment MNAR = 8139 in*KIP MDU14N = MMA-U—n MmsIGN = 8139 in*KIP MGERIGN Weiaht FTYDEBIGN = 'M S A,_ FTY—mN = 24.9 KSI Elry - > F—..- 54 —.. N54 RSI > 24.9 KSI => OK ACER PROJECT NO. 20150006 DATED 05/08/2015 Rat:ACI 318 BNx LD1NG CGDE REQUIREMENTS ' valmont By: NAR DRILLED PIER ANALYSIS Site: SOUTHOLD - Check: NAR POLE STRUCTURE MICROFLECf Dwg B-145362 A-279216 Date: 01/30/17 KMB DESIGN valmont;V MiCROFLECT Mon roO,e P a=neHsQ CHSTOMOt:RM0 DR8SQ1 6ITE:avamwa .D.1 2]9218 .H-145362 Geotel Rpt AGER PRO06CT NO.2015DD06 DATED 05/08/2015 Geotec Report Water Depth 38.7 FT Otigioi.Ron Dot.: 01/30/17 VEASION:1.15 Evgiveat:NA8 Check¢:RAR ' Polo Ge®Bkry Bole height- 34 ft ..it CSrCle 54.5.Inches 4 of Bolts B Belt Diameter 1.]5 Inches _ Bolt Projection. 8.-05 Inches Bolt Length- 66.0Inche5 Bottom Template Diameter- 5B.D Inches Pole!.Dade Factored Mot."" 630.1 ft-Kips Factored Sheat 11.77 zips Factored Wei qht- 22.GD Kips Shear Haight• 535 Ft e (col offset)- 343..]in or Anehet Holt Toed Facted Nmaent- 7562 in-Kips Factored Shear 11.77 Kips Factored Weight. 22.OD Kip, Anchor Holt Alloveble Fu 100.D Wei FY- 75.0 K.i Area tensile 1.90 inz S awl +Vltimatal {Hltimat.ZERO=GROUND LINE ea aveouae Daptp Start Depth end :+•_�S=ev_S*. Level f PPSF Etart wPSF/FT If t) (fol Entl Prss (f[) ,{IIeP�umry Pessile 1 0 30d.d3921]d 0 3B 11569 3.59 C. dA=Applied 2 10203 130.8344498 38 50 11]73 ..oi�_� R 3 M(in-Kip.) -(ft-Kips) Cbvvd_�4 4 8139 67KB 5 oN g Tc�.LS.I-At:S L- aP Neignt IAbove ozaena 61aaI- 0.5 Ft Diameter Pier- 6 Ft - Length (Delo.gr...d) 2D C...tate valvme - 21.5 tubi.Fntdo Load xnttectian-event aapth ILIDI• 14.3] FC R..ive4 OTM BD5.2£t-R'iPo I.--� 1428..e ei11'.77,�•,•^•a+...e/.n 1. sheat_._: 11.8 Ripa 6haota.,i.ti,e 11.87 1.01 .w...eiav w__v Wokght 22.0 Hip. Tewdatiev teas Prapctlae Abouk load-tion Point ZERO GROUND LINE t<ea atvea N-1" a..iv. ....,.. ., .,... Depth Start Depth Rod ...Hunt Psiop• canauac �seiapa Laval I tPSF Start t PEF/FT we (ft) (ft) Kip. ups Eip-rc pl_ 1 0 304 0.0 14.4 0.D0 188.60 D X903 176 P73 2 4375 304 14.4 38.0 -Sd7.7B -28.95 416 109 3 10203 131 38.0 50,0 0.00 0.00 0 0 Ti.Hat I 4 Tie.OA SeismicTies]..; Tie Vettieal 6recing 1 FT - 12• Number of Tien 23- Ar.a_Ties 0.4in^2 VERTICAL 111TIOH R­of the tie) IB_- d in TRIC101E55 OF CONCRETE COVER bo R 30.9 in RADIOS OF VERT.HEBAR 14P Aoteol 22.0 ry"2 TOTAL AREA OF VERT.OAR, 29000 ESI PN I.tsol 10527 in"4 DEBAR MuB.NT OP INERTIA 11 305294515 in"2•LB 340.3 Ln"3 :L-TICK RGDOLDS M 8139 in•KIP APPLIED MAX MIN MOVNT @ AT DEPTH ZERO SHEAR OU FIER Vertical Esr 0 9 15 Mi..based ov 20Oab.ad/fy per ACI 31B Bae Camt 22 >. 21 Mi..L...d t.. {aea.a o.85 ..travg[A Reduction F1111 or .city Ot sceel Sheer 0.9 revgN Hetluc[Son-to.fat Capacity Of Steel Plerure MP Fry TN 60 Esi REBAR"I GtaI 60 iR Fty TN ALL 54 Ksi DEBAR It, Allowable Pier Design Secludes PRI Steel FTYDESIGN 24.9 K.i cel.Mated {V4 127.2 Kip DEBAR.hear Allowable Piet D-He ACI 318 Vet[ical Rebar Horir Spaclvg- 7.71 in Diameter of hoops. FT Diameter of ve[tioel rebel cit is- 61.875 in reetfag eaoamta Ra9.iraota 4000 p.i oncre to conptea,itn p ttiea I D-85 ore 9th Re union Felt,,for Capeclty Of Concrete {V. 434 Kip. SHEAR CAPACITY OF CONCRETH ACI 318 d 4.66 FT diatavice from eetteme cum Eiber to cent of ten.ion[section g[oup Arif R.Malick,PE,CME Principal ,�\\r Glenn J.Scherer,PE Principal Colleen Connolly,PE,PTOE MRS0�0 Associate Robert Zalewski,PE,CFM, CSM Malick6Scherer, PC. Associate Steven C.Ra auo,PE Consulting Engineers•Construction Inspectors•Land Surveyors Director of Structures Michael J.McAlpin,PLS Director of Survey June 26,2014 Town of Southold 53095 Route 25, P.O. Box 1179 Southold, NY 11971 RE: New Cingular Wireless PCS, LLC Site#LI-1025 1040-B Horton's Lane Southold, NY 11971 District 1000,Section 63, Block 1, Lot 10 Dear Building Official, New Cingular Wireless PCS, LLC is proposing a 74'tall unipole mounted atop a 1'tall caisson (75'overall height to top of structure),and associated equipment at the above referenced property. The unipole and foundation are designed in accordance with all applicable codes and requirements including, but not limited to,The Building Code of New York State,TIA/EIA-222-F and TIA/EIA-222-G.The unipole manufacturer will provide a structural analysis that demonstrates the compliance with the codes and requirements listed above. The associated equipment will be located within the adjacent storage facility building, mounted to the concrete slab (floor).The existing concrete slab has the structural capacity to support the proposed equipment. Additionally,an Emergency Backup Generator will be installed outside of the storage facility directly adjacent to the equipment location.The Generator will be mounted on a proposed concrete slab.The concrete slab will have adequate structural capacity to support the generator as per all applicable codes and requirements. Feel free to contact me with any questions or concerns at 908-537-1300. Ve�P�CI�F N�C W yO C-2 n J feslo nen 75376 O 07531 Q, pROFESS10 Perryville III Corporate Center • 53 Frontage Road,Suite 260 • Hampton, NJ 08827 Ph 908.537.1300 • Fax 908.537.1398 TOWN OF SOUTHOLD FORM NO. 3 NOTICE OF DISAPPROVAL DATE: August 25, 2014 TO: Re, Nielsen, Huber& Coughlin for YSI XXXII, LLC 36 N. New York Ave., Huntington, NY 11743 Please take notice that your application dated July 29, 2014 For permit to construct a Wireless telecommunications facilites Location of property: 1040 Horton Lane, Southold, NY County Tax Map No. 1000- Section 63 Block 1 Lot 10 Is returned herewith and disapproved on the following grounds: Pursuant to Article XVII, Section 280-70, G) Fall Zones, a smaller fall zone may be allowed if supported by a report from a structural engineer. Section 280-71- Required approvals states Site Plan and Special Exception approval from the Southold Town Planning Board is required. Authorized Signature CC: file, Planning Bd. Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. FOR INTERNAL.USE ONLY . N USE DETERMINATION - SITE P LA Initial Determination � - I 1 . Date Sent: �- project Name: Project Address: Zoning District---L-T,-- . Suffolk � County Tax Map No.:1000= - Request: a (Note: Copy of Buildtrg Peril Application and supporting documentation�a&to -proposed use or uses should be submitted.) Initial Determination as to whether use is permitted: 'on as to whether site plan is required: Initial Dete.rminati y�S f Signature of Building Inspector Planning Department(P.D.) Referral: -Date of Commen P.D. Date Received: — t:_ -- Comments: Signature of Planning Dept.-Staff Reviewer Final Determination Date: 1 �— Decision: CinnattlrP of Riiildina Insnpator va' montes STRUCTURES January 16,2015 Don Huntley,PE Market Engineer Bechtel Communications,Inc. 300 Broadacres Drive Suite 250 Bloomfield,NJ 07003 8 201.571.0692 Ref: Design and failure modes for a 75-ft/95-ft Tapered Monopole Quality of Steel and Fabrication of a Monopole Structure Site:AT&T LI 1025—1040-B Horton's Lane,Southold,NY Pole to be designed with a 35'theoretical fall point Valmont SO#279218 1 have reviewed Code Section 280-70G and am offering the following comments: • The communication monopole structure for this project is required to be sized in accordance with ANSI/TIA/EIA-222-F and ANSI/TIA-222-G. These standards have been approved by ANSI/ASCE, which has dealt with the design of antenna support structures for over 40 years. The TIA standard, based on provisions of this nationally known specification, has a long history of reliability. At its core philosophy is It's first and foremost priority to safeguard and maintain the health and welfare of the public. • The TIA standard designates a minimum wind loading for each county in the United States. Valmont uses the wind loading listed in the TIA standard unless a greater value is specified by our customer. Structures are also designed for radial ice at a code specified reduced design wind loading. Code designated coefficients are used to ensure that the structure will survive the designed wind speed. The structure can usually survive even a greater wind load than the baste design wind speed because of these conservative coefficients. • Design and loading assumptions that are used for the analyses of these structures are very conservative in nature when compared to other codes,which makes structural failure highly improbable. • Failure of a steel monopole occurs when a point is reached where the induced stresses exceed the yield strength of the material. At this point,the deflections induced in the material are no longer temporary. Hence,a permanent deflection in the monopole would exist. • The term failure above refers to local buckling at a designated point on the pole. Local buckling does not cause a free failing pole;rather it relieves the stresses from the pole at this location. Monopoles are flexible,forgiving structures,which are not generally susceptible to damage by impact loads such as wind gust or earthquake shocks. • When local buckling occurs,a relatively small portion of the shaft distorts and'kinks'the steel. When the pole begins to bend the exposure area is reduced and therefore,the force due to wind is decreased as well. Even though buckling exists,the cross section of the pole is capable of carrying the entire vertical load, Therefore,wind induced loads could not conceivably bring this type of structure to the ground due to the excellent ductile properties,design criteria,and failure mode. Quality of Steel and Manufacturing: • Monopoles are fabricated from ASTM A572 Grade 65 material with a controlled silicon content of 0;06% maximum to ensure a uniform galvanized coating. The base material is fabricated from Grade 50 material. All plate material meets a V-Notch toughness requirement of 15 ft-lbs.@-20 degrees Fahrenheit. By meeting the strict toughness requirement,monopoles are best suited to resist the cyclic/fatigue type loading(i.e.wind induced loading)these structures exhibit. • Anchor bolts are fabricated from A615 Grade 75 material. The bolts are typically 2%in diameter,made from#18J bar stock. Anchor bolts come complete with five(5)A194 Grade 2H hex nuts, Valmont Mierotlect,Valmont Industries,Inc. 3375 25'h Strect Salem,OR 97302-1123 USA Toll Free,800-547.2151 Fax;503.316-2040 wwv.valmonl corn i valmont STRUCTURES • Fabrication of the monopole should be performed at an AISC qualified facility. This will ensure that the provisions of the AISC Manual of Steel Construction are followed. Also,all welding and inspection should be in accordance with the American Welding Society's Specification D1.1 (latest revision). In addition,this monopole can be designed to theoretically fail at approximately the 35-ft elevation by purposely over designing the pole sections below this point.In the unlikely event the pole were to fail at this point,the significant loading reduction caused by the removal of the tower wind area and weight above would greatly reduce any chance that the remaining tower would have any structural damage,thereby providing a theoretical failure radius of approximately 40-ft as designed,or 60-ft if approved with a total height of 95'. 1 hope these comments address any issues that you might encounter relative to the anticipated performance of the monopole structure and the quality of steel fabrication. In consideration of the parameters above and given the fact that there are presently no structures or areas of congregation within 60'of the pole,we respectfully request that the Planning Board waive the"fall zone"requirements of the Code. If you have additional questions or comments,I may be reached at 503.589-6618. Sincerely, David Casey Proj.Eng. OF NEw IAM re,t 0 � y fi ysFO O P JAN 2 12015 Valmont Microftect,Valmont Industries.Inc 3575 25'u Street Salem,OR 97302.1123 USA Toll Free:800-547-2151 Fax:503.316-2040 wwwYalmontcom MAILING ADDRESS: PLANNING BOARD MJ. SMSERS OF SOyOo P.O.soi1s oSouthold,Box 1179 Chair OFFICE LOCATION: WILLIAM J.CREMERS Town Hall Annex PIERCE RAFFERTY �pQ 54375 State Route 25 JAMES H.RICH III Oly (cor.Main Rd. &Youngs Ave.) MARTIN H.SIDOR COUSouthold, NY Telephone: 631 765-1938 www.southoldtownny.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD State Environmental Quality Review NEGATIVE DECLARATION Notice of Determination Non-Significance April 6, 2015 This notice is issued pursuant to Part 617 of the implementing regulations pertaining to Article 8 (State Environmental Quality Review Act) of the Environmental Law. The Southold Town Planning Board, as lead agency, has determined that the proposed action described below will not have a significant effect on the environment and a Draft Environmental Impact Statement will not be prepared. Name of Action: New Cingular Wireless/AT&T at 1040B Hortons Lane SCTM#: 1000-63-1-10 Location: ±400'n/o Traveler Street& Hortons Lane, Southold SEQR Status: Type I ( ) Unlisted (X) Conditioned Negative Declaration: Yes ( No (X) Description of Action: This proposed Site Plan is for a 95' high wireless telecommunications monopole to include six (6) AT&T panel antennas and four(4) empty 10' sections for possible future co-location (all concealed within the pole), along with 300 sq. ft. proposed within an existing building for associated ground equipment on 6.9 acres in the Light Industrial Zoning District. Reasons Supporting This Determination: An Environmental Assessment Form has been submitted and reviewed and it was determined that no significant adverse effects to the environment were likely to occur should the project be implemented as planned. The property is currently improved with self-storage facility use. The monopole is proposed to be located where an existing flagpole currently exists. • "a ?v 64 °' e 4 UO- S t fi The property is zoned Limited Industrial (LI). Zoning Districts located within the vicinity of the parcel include R-40 and R-80 (Residential) to the north and west. Hamlet Business (HB) to the south and Hamlet Density (HD) to the east. The dominant surrounding land uses within the vicinity of the site include mixed residential. The site is improved, therefore, the proposed action will not result in the significant removal or destruction of large quantities of vegetation. The impact to soils resulting from the construction of the new equipment cabinets would be negligible. The design includes the placement of supporting equipment in existing storage units on the property. Based on the existing use and improved facilities, the proposed action will not cause a substantial intensification of use over the current use. No agricultural soils, open space or recreational resources occur on site, therefore, the proposed action will not cause significant impacts to agricultural, open space or recreational resources. No substantial adverse change in existing air quality, ground or surface water quality or quantity, traffic.or noise level will occur as a result of the proposed action. County Route 48 (CR 48), located to the north of the parcel and New York State Route 25 (SR 25), located to the south of the parcel are New York State Scenic Byways. A Visual Analysis prepared by VHB Consulting Services and Malick & Scherer LLC., dated March 2014 and September 30' 2014, indicates that the proposed action will not result in significant aesthetic impacts over existing conditions due to the mitigation proposed, improvements of the lot and existing vegetative screening. Therefore, the Planning Board in consideration of the findings of the Visual Analysis has determined that the action would not result in significant impacts to view sheds from CR 48 or SR 25 or those identified as important to the community. The proposed action is located within an,Archeo-sensitive area (Mapinfo 2015). Due to the improvements on the parcel and the minimal new ground disturbance proposed, the action would not result in adverse impacts to cultural/historic resources nor impair the character or quality of important historical or architectural resources. The site is currently improved and the proposed action will not result in significant adverse impacts to aesthetic resources or to existing community or neighborhood character or result in a material conflict with the community current plans or goals as officially approved. Based upon such, no significant, adverse impacts to the environment are expected to occur should the project be implemented as planned. This determination is based, in part, on the Planning, Zoning and Visual Impact Analysis (March 2015) prepared by VHB;the Real Estate Consulting Report, dated March 9, 2015, prepared by Lynch Appraisal LTD; the RF Exposure Analysis for Proposed Upgrade New Cingular Wireless PCS, LLC;AT&T Antenna Facility prepared by Betchel Communications, Inc. and testimony heard at the March 9, 2015 Public Hearing. For Further Information: Contact Person: Mark Terry, Principal Planner Southold Town Planning Board, 631/765-1938 cc: Town Board Building Dept. 3 MAILING ADDRESS: PLANNING BOARD MEMBERS if SOy® P.O.Box 1179 DONALD J.WILCENSKI �� l� Southold, NY 11971 Chair OFFICE LOCATION: WILLIAM J.CREMERS CA Town Hall Annex PIERCE RAFFERTY �p 54375 State Route 25 JAMES H.RICH III ���, ^a (cor.Main Rd. &Youngs Ave.) MARTIN H.SIDOR Own Southold, NY Telephone: 631 765-1938 www.southoldtownny.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD — -- - r 1\ April 7 2015 1 lj APR 24 2015 John Coughlin, Esq. _ - c/o Re, Nielsen, Huber & Coughlin, LLP 36 North New York Avenue Huntington, NY 11743 Re: Approval: Proposed Site Plan for New Cingular Wireless/AT&T at 10408 Hortons Lane Located at 1040B Hortons Lane, ±400'n/o Traveler Street & Hortons Ln., Southold SCTM#1000-63-1-10 Zoning District: Light Industrial Dear Mr. Coughlin: The following resolutions were adopted at a meeting of the Southold Town Planning Board on April 6, 2015: WHEREAS, this proposed Site Plan is for a 95' high wireless telecommunications monopole to include six (6) AT&T panel antennas and four (4) empty 10' sections for possible future co- location (all concealed within the pole), along with 300 sq. ft. proposed within an existing building for associated ground equipment on 6.9 acres in the Light Industrial Zoning District, Southold; and WHEREAS, the agent to the applicant, John Coughlin, Esq., submitted an application for Site Plan review and Special Exception review on October 27, 2014; and WHEREAS, on November 17, 2014, the Planning Board found the application incomplete for review with revisions to be made and further information to be submitted; and WHEREAS, on November 20, 2014, pursuant to §280-74A(4) of the Town Code, the Planning Board entered into a Letter of Agreement with Cityscape Consultants, Inc. to assist the Board in reviewing and evaluating the proposed wireless application; and WHEREAS, on January 23, 2015, the agent to the applicant, John Coughlin, Esq., submitted the information requested; and WHEREAS, on February 9, 2015, the Planning Board formally accepted the application as complete for review; and 10408 Hortons Lane Pae 12 April 7, 2015 WHEREAS, on February 9, 2015, the Southold Town Planning Board, pursuant to the State Environmental Quality Review Act §617.6, established itself as lead agency for this Unlisted Action; and WHEREAS, on February 12, 2015, the Southold Town Planning Board, pursuant to §617.6 of the Environmental Conservation Law acting under the State Environmental Quality Review Act, initiated the SEQR lead agency coordination process for this Unlisted Action; and WHEREAS, on February 12, 2015, the Planning Board, pursuant to Southold Town Code §280-131 C., distributed the application to the required agencies for their comments; and WHEREAS, on March 2, 2015, the Southold Fire District determined there was adequate fire protection and emergency access for the site; and WHEREAS, on March 6, 2015, the Southold Town Fire Inspector reviewed and determined that there was adequate fire protection and emergency access for the site; and WHEREAS, on March 9, 2015, a public hearing was held and closed by the Planning Board for the above-referenced Site Plan; and WHEREAS, on March 18, 2015, the Town of Southold LWRP Coordinator reviewed the above-referenced project and has recommended the proposed project be found consistent with Southold Town LWRP policies; and WHEREAS, on March 18, 2015, the Southold Town Engineer reviewed the above-referenced application and determined the project meets the minimum requirements of Chapter 236 for Storm Water Management; and WHEREAS, on March 19, 2015, the Architectural Review Committee (ARC) reviewed the proposed project and approved the design as submitted; and WHEREAS, at a Work Session held on March 23, 2015, the Planning Board reviewed the report issued by Cityscape Consultants and determined that an increase in overall height of the proposed tower from 75' to 95' with potential future co-locations would achieve the result of fewer antenna support structures in the immediate area of this commercial zone; and WHEREAS, at a Work Session held on March 23, 2015, the Planning Board reviewed the recommendation to waive §280-701(2) for the maximum height of 80 feet in this Light Industrial (commercial) Zone. They found that an increase in overall height of the proposed tower to 95' with potential future co-locations would achieve the result of fewer antenna support structures in the immediate area of this commercial zone; and WHEREAS, at a Work Session held on March 23, 2015, the Planning Board reviewed the request to waive §280-701(3) for the minimum distance of all wireless equipment to adjacent residential property lines. They found that the proposed ground equipment is contained entirely within an existing storage building on site and the proposed tower has been certified to be constructed with a smaller fall zone; and 10408 Hortons Lane Pae 13 April 7, 2015 WHEREAS, at a Work Session held on March 23, 2015, the Planning Board reviewed the request to waive §280-70N(4) for base equipment and shelter landscaping. They found that the proposed ground equipment is contained entirely within an existing storage building on site which accomplishes the goal of concealing the base equipment shelter from other properties and roads; and WHEREAS, at a Work Session held on March 23, 2015, the Planning Board found that all applicable requirements of the Site Plan Regulations Article XXIV, §280 — Site Plan Approval of the Town of Southold have been met; and WHEREAS, on March 27, 2015, the Southold Town Chief Building Inspector reviewed and certified the proposed Wireless Communication Facility as a permitted use in the Light Industrial Zoning District; and WHEREAS, on April 2, 2015, revised Site Plans showing the 95' tower height were submitted by the agent to the applicant, John Coughlin, Esq., and reviewed by Cityscape and the Planning Board and accepted; and WHEREAS, the Southold Town Planning Board, in their Special Exception Approval resolution on April 6, 2015, and pursuant to Part 617, Article 6 of the Environmental Conservation Law acting under the State Environmental Quality Review Act, granted a Negative Declaration for this Unlisted Action; and WHEREAS, at their public meeting on April 6, 2015, the Planning Board granted approval to the Special Exception Application for this site; be it therefore RESOLVED, that the Southold Town Planning Board hereby waives §280-701(2) of the Town Code for the maximum height of 80 feet in this Light Industrial Zone as described above; and be it further RESOLVED, that the Southold Town Planning Board waives §280-701(3) for the minimum distance of all wireless equipment to adjacent residential property lines as described above; and be it further RESOLVED, that the Southold Town Planning Board waives §280-70N(4) for base equipment and shelter landscaping as described above; and be it further RESOLVED, that the Southold Town Planning Board has determined that this proposed action is consistent with the policies of the Town of Southold Local Waterfront Revitalization Program; and be it further RESOLVED, that the Southold Town Planning Board grants Approval with a Condition to the Site Plan entitled "AT&T @ 1040B Hortons Lane", prepared by Malick & Scherer, P.C. on January 21, 2010, last revised on April 2, 2015, and authorizes the Chairman to endorse the Site Plan, including the following twelve plans: 1. Z01 — Cover Page 2. Z02 — Key Map 3. Z03 — Key Map; Founders Village Condominiums 10408 Hortons Lane Pae 14 April 7, 2015 4. Z04 — Radius Map /Vicinity Map 5. Z05 — Historical / Cultural and Landmark Locations 6. Z06 — Site Plan 7. Z07 — Detailed Site Plan 8. Z08 Equipment Room 9. Z09 — Elevation and Details 10.Z10 — Generator Detail 11.Z11 — Mechanical Details 12.Z12 — Equipment Specifications The condition is as follows: 1. Prior to a Building Permit being issued, a "Letter of No Objection"from the Long Island Rail Road must be provided to this department. Please note the following requirements in the Southold Town Code relating to Site Plans: 1. Any outdoor lighting shall be shielded so the light source is not visible from adjacent properties and roadways. Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries. 2. All storm water run-off from grading, driveways and gravel areas must be contained on site. 3. Approved Site Plans are valid for eighteen months from the date of approval, within which time all proposed work must be completed, unless the Planning Board grants an extension. 4. Any changes from the Approved Site Plan shall require Planning Board approval. 5. Prior to the issuance of a Certificate of Occupancy, the Planning Board must inspect the site to ensure it is.in conformity with the Approved Site Plan, and issue a final site inspection approval letter. Should the site be found not in conformance with the Approved Site Plan, no Certificate of Occupancy may be issued unless the Planning Board approves the changes to the plan. A copy of the Approved Site Plan is enclosed for your records. One copy will also besent to the Building Department and the Town Engineer/Highway Department. If you have any questions regarding the above, please contact this office. Very truly yours, )Inmes H. Rich, III Vice-Chairman Encl. cc: Building Dept. with map/Town Engineer with map 1040B Hortons Lane Pae 15 April 7, 2015 By signing this letter, the applicant acknowledges that there are Town Code requirements and conditions, including those listed above, that must be satisfied prior to the issuance of a Certificate of Occupancy. Print name: Applicant/Agent Signature: Date: '0)r� �� M_AJ_JNG ADDRESS: PLANNING BOARD MEMBERS �Qv sorry P.O. Box 1179 DONALD J.WILCENSKI �� �� Southold,NY 11971 Chair ~ � OFFICE LOCATION: WILLIAM J.CREMERS y Town Hall Annex PIERCE RAFFERTY p 54375 State Route 25 JAMES H.RICH III (cor.Main Rd. &Youngs Ave.) MARTIN H.SIDOR �'��'DUMV, Southold,NY Telephone: 631765-1938 www.southoldtownny.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD April 7, 2015 John Coughlin, Esq. c/o Re, Nielsen, Huber & Coughlin, LLP 36 North New York Avenue Huntington, NY 11743 Re: Approval and SEQRA Determinatidn: Special Exception for New Cingular Wireless/AT&T at 1040B Hortons Lane Located at 1040B Hortons Lane, ±400'n/o Traveler Street & Hortons Ln., Southold SCTM#1000-63-1-10 Zoning District: Light Industrial Dear Mr. Coughlin: The Southold Town Planning Board adopted the following resolutions at a meeting held on Monday, April 6, 2015: WHEREAS, an application for a Special Exception & Site Plan Approval for a wireless communication facility was accepted for review on February 9, 2015, including a Site Plan prepared by Malick & Scherer, P.C. on January 21, 2010; and WHEREAS, the Southold Town Planning Board reviewed the above-referenced request for a Special Exception for a 95' high wireless telecommunications monopole to include six (6) AT&T panel antennas and four (4) empty 10' sections for possible future co-location (all concealed within the pole), along with 300 sq. ft. proposed within an existing building for associated ground equipment on 6.9 acres in the Light Industrial Zoning District, Southold; and WHEREAS, on February 9, 2015, the Southold Town Planning Board, pursuant to the State Environmental Quality Review Act §617.6, established itself as lead agency for this Unlisted Action; and WHEREAS, on February 12, 2015, the Southold Town Planning Board, pursuant to Part 617, Article 6 of the Environmental Conservation Law acting under the State Environmental Quality Review Act, initiated the SEAR lead agency coordination process for this Unlisted Action; and 1040B Hortons Lane Pae 12 April 7, 2015 WHEREAS, the submission by the applicant has been reviewed and corroborated with an independent radio frequency engineer retained by the Town to assist in the review process; and WHEREAS, on March 9, 2015, a public hearing was held and closed; and WHEREAS, on March 23, 2015, the General Requirements in §280-70 were met; and WHEREAS, on March 23, 2015, the Southold Town Planning Board made a determination that the applicant has satisfied the requirements for a Special Exception pursuant to Town Code Section 280-142 and the additional standards for a Special Exception in Town Code Section 280-73B as detailed in the Staff Report dated March 23, 2015; and WHEREAS, on March 27, 2015, the Southold Town Building.Inspector reviewed the plan and certified that the proposed Wireless Communication Facility is a permitted use in the Light Industrial Zoning District; therefore, be it RESOLVED, that the Southold Town Planning Board, pursuant to the State Environmental Quality Review Act, performed a coordinated review of this Unlisted Action and, as lead agency, made a determination of non-significance and grants a Negative Declaration; and be it further RESOLVED, that the Southold Town Planning Board hereby finds and determines that the standards for Special Exception Approval have been met; and be it further RESOLVED, that after deliberation of the application and consideration of the above factors, the Southold Town Planning Board grants a Special Exception for the Wireless Communications Facility as shown in the Site Plan Application for"AT&T @ 1040B Hortons Lane", prepared by Malick & Scherer, P.C. on January 21, 2010, and last revised on April 2, 2015. Please also note the following requirements in the Southold Town Code relating to Special Exceptions: 1. Any Special Exception Approval granted under this article shall have a term of five years, commencing from the granting of the Special Exception, which may be extended for an additional five-year term upon application to the Planning Board. 2. On a renewal application, the applicant shall demonstrate that the wireless communication facility is in compliance with all applicable laws, rules and regulations and with all of the conditions of the Special Exception Approval and Site Plan, that the facility is necessary to provide adequate service, and that there is no reasonable alternative available to the owner which will provide adequate service without the continuing use of the facility. 3. Subsequent Special Exception renewals shall be subject to review by the Planning Board and subject to such standards that shall be included in the Town Code at that point in time. 1040B Hortons Lane Pae 13 April 7, 2015 Enclosed please find a copy of the Negative Declaration for your records. If you have any questions regarding the information contained in this resolution, please contact the Planning Board Office. Very truly yours, Cc aures H. Rich, III Vice-Chairman Encl. cc: Town Engineer Building Dept. -rToa vn of Southold} New York 191P mor-�MENEEMENIN Telecommunications Site Review Consultants, Inc. Equipment. Upgrade Application 7050 West PalmeBoca Ra on F#15-652 33433 Tel:877.438.2851 Fax:877.220.4593 November 10, 2015 D C � ❑„ E f Ms. Heather M. Lanza, AICP N 0 V 12 2015 Planning Director Town Hall Annex Building Southold Town 53095 Route 25 Planning Board Southold,New York 11971 RE: New Cingular Wireless PCS,LLC (AT&T) Dear Ms. Lanza, At your request, on behalf of the Town of Southold ("Town"), CityScape Consultants, Inc. ("CityScape") in its capacity as telecommunications consultant for the Town, has considered the merits of the above referenced application submitted by AT&T Mobility ("Applicant") to modify and upgrade their equipment on an existing one hundred eleven (I 11) foot monopole tower, owned by Crown Communications. The tower is located at 21855 Country Road 48, Cutchogue,New York, see Figure 1. Support Structure&Equipment The purpose of the proposed modification is to allow the Applicant to add equipment for upgrades for fourth generation (4G) advanced wireless services, by replacing antennas and Remote Radio Heads (RRH) that will support higher speed wireless broadband. These modifications to the tower equipment will occur at the seventy (70)foot level,Appendix, Exhibit A. The Applicant currently maintains nine (9) panel antennas; three (3) per sector. Three (3) new antennas (one per sector) will replace three of the existing antennas at the same locations. Additionally the Applicant will add three (3) new RRHs to the existing three (3) for six (6) total RRHs. The new antenna configuration is depicted in Appendix, Exhibit B. The referenced facility and tower has been designed, constructed and continues to be operated by the Tower Owner and professionals with expertise in telecommunications site design and construction. The facility has been designed to maximize the use of telecommunications facility and will have the capability to provide space for future collocation opportunities. Town pf Southold,New York `�. ��"� �■■_!!!T '"'Page 2 r p- kid Sol Consultants, Inc. Structural Analysis The Applicant submitted a structural analysis, prepared by Paul J. Ford & Company, dated March 9, 2015 and based on ANSI/EIA/TIA-222-F standards. The report summary indicates that with the upgrades, the tower is still within its design limits, see Appendix, Exhibit C. Specifically, the tower with the existing and proposed equipment will have a stress rating of 93.2% while the base (foundation) rating will have a stress rating of 77.6%. CityScape found that Nextel has removed six (6) antennas at 250 feet and twelve (12)feedlines from the ground to 250 feet. It is unusual for Nextel to remove or decommission a site without converting the same to a SprintPCS facility, but that apparently did happen since the Nextel electronic equipment shelter has been removed. Wireless applications, other than new support structures are governed under the Middle Class Tax Relief and Job Creation Act of 2012 (Tax Relief Act) and shall be afforded streamlined processing with a qualified application. A qualified application under the Tax Relief Act cannot increase in size of the ground compound, or tower structural changes increasing the height or girth by ten percent (10%) or twenty (20) feet, whichever is greater. Since the Applicant will not be increasing the height or girth of tower, nor the compound, this application is qualified for streamlined processing under the Tax Relief Act. The submitted application conforms to the requirements of Town codes and State of New York wind codes and structural integrity. Therefore, it is Cityscape's recommendation that the Town approve the application with the following condition: The facility shall remain secured and protected from unauthorized personnel. I certify that to the best of my knowledge all of the information included herein is accurate at the time of this report. CityScape is only employed by local governments and has unbiased opinions. All recommendations are based on technical merits without prejudice, according to prevailing laws and codes. Respectfully submitted, Jonathan N. Edwards,P.E. Cityscape Consultants, Inc. Town,of Southold,New York Page 3 �titit AM. a � o��J Consultants, Inc. s •' DeLormeStreet Atlas USAW 2009 r ,m Q°' 48 try Pc VtiJ�a� - ��geQ�✓SdJt � �� J 4. C <� r L J Go`o v��'� m 25 m fcutd�6 6e q ° g � 4, 4' ' v >r.`' '�. •�,i " t ,i4. 'fir=-' ; Data use subject to license. ft O Del-orme.DeLorme StreetAtlas USA®2009. 0 600 1600 2400 3200 4000 www.deforme.com MN(13.7-W) Data Zoom 13-0 Figure 1 — Site Location Town,of Southold,New York p"qpm! °'"'"t■�����!� Page 4 M � o oil Consultants, Inc. Appendix Town.of Southold,New York Page Pa e 5 Consultants, Inc. RAO. CENIER OF-EX61INO BfETa70F'�'JI>�TEP,N.� ITA —67 *'&OO L TOPof: T:]-SIti<tG TOWER ice. WMER 0< E3 IS RID VERIZON ANWi?05 [ala CE a1 t2 Ci fnx( it a r T. . .... ar Et : .5 E atNC qAqCAP CC$ DYAE ON - MUNO ^IK tFAMST ON 'j'...,4p;AP.aO ti�WER C� EairSlt`t tdEVEL fcNTEividS- s'=er' W . JN!STAk1, (t)JM PAH. s7rlH* i t{STiNOE SEE TA 'Q fAO�j P'5 o Tf_f =: E t df`t T20 +7SEf�_ 4iCc #sN u (TYP.-ALL .'q£CTOR.S) 7O' : .kGL (TYP. &L SECTORS) "L5�MW I'E ( E CCML 7fA�) �YYYtg AZL SEi:I'c��y " (r!rP.. ALL SECTORS), ANDREW ,IINTMIA PROPUSE0 CTE AkDREW AT*T (SSNIM-1065A) HEXP+ >i ANTENNA Ch EXiSTINfi jjFE MAS.' (TYP;"ALL, SECTORS) cut OC Tan, 7 AW) EXISTING SOLE rx1STf1� flt�s'�[.IPdI, ofim - Tip Qs L`F.,cDE Exhibit A - Existing Support Structure Town of Southold,New York •of MEMEMENEW and d 10G T� Page 6 m Consultants, Inc. (°ACCT' 4) S .E TING (1) .LTE ANDREW ANTENNA�A TK, (.I) PRO E0 07t i4.i+tOR44 1 AT4T'; XP—QRT S DE EE JAIL 2WAOX INSTALL (1) ISO MHz RAH CR EKISIMGJNPE ' (SEE: OETAIL f f A- ) T Ell.NNG V PE.MAST ' T-APkJ M5Tjkr, (1) 700 kC RRH''.IONXISTIlsN�, M; EF, wEy WNG AT&T 94ENNA TO 1 A Exhibit B— Proposed Antenna Configuration Town of Southold,New York Page 7 .t. 1::3." .. Consultants, Inc. STRUInPAUL J. FORD AND COMPANY CTU RAL E N G I N EER S 250 East Broad Street • Suite 600 • Columbus,Ohio 43215-3708 Date: March 09,2015 Marianne Dunst Paul J.Ford and Company Crown Castle 250 E.Broad Street,Suite 600 3530 Toringdon Way Suite 300 Columbus,OH 43215 Charlotte,NC 28277 mscroggy@pjfweb.com Subject: Structural Analysis Report Carrier Designation: AW Mobliity Co-Locate Carrier Site Number: NYCENY1027 Carrier Site'Name: NA Crown Castle Designation: Crown Castle BU Number: 806579 Crown Castle Site Name: NY Cutchogue 958280 Crown Castle JDE Job Number: 325398 Crown Castle Work Order Number: 1020795 Crown Castle Application Number: 249744 Rev.1 Engineering Finn Designation: Paul J.Ford and Company Project Number: 37515-0232.002.7805 Site Data: 21855 COUNTRY RD,CUTCHOGUE,Suffolk County,NY Latitude 41°1'4&5T,Longitude-72'29'50.29" 108.5 Foot-Monopole Tower Dear Marianne Dunst, Paul J.Forel aril Company is pleased to submit this"Structural Analysis Report"to determine the structural integrity of the above mentioned tower. This analysis has been perronned in accordance with the Crown Castle Structural'Statement of Work'and the terms of Crown Castle Purchase Order Number 763689,in accordance with application 249744,revision 1. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation,under the following load case,to be: LCT Existing+Reserved+Proposed Equipment- Sufficient Capacity Note-,See Table I and Table II forthe proposed and existing/re5erved loading,respectively. The structural analysis was performed for this tower in accordance with the requirements of TIAIEIA-222 F Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a fastest mile wind speed of 85 mph with no ice,37.6 mph with 0.75 inch ice thickness and 50.mph under service loads. We at Paul J.Forel and Company appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. Respectfully submitted by: Morgan Scroggy,E.I. Structural Designer tnxTower Report-version 6.1.4.1 Exhibit C — Structural Analysis Summary Hillside Maintenance Complex Patrick A.Nowakowski 93-59 183 Street President ' Hollis,NY 11423 Long Island Rail Road April 23,2015 Mr.John Coughlin Nielsen,Huber&Coughlin,LLP 36 North New York Ave Huntington,NY 11743 Re: Re 15-30; 10408 Hortons Lane Southold NY 11971 Dear Mr.Coughlin, The Long Island Railroad (LIRR) Engineering Structures Inspection Group has received your package submittal dated March 26, 2015, for the construction project at the above location. We have reviewed the submitted Suffolk County tax map; zoning drawings,stamped construction drawings by Malick & Scherer P.C. dated January 21, 2010, property survey, and the miscellaneous Town of Southold application documents. Additionally, a site visit was conducted April 21, 2015. We have determined that your work has no impact on the operation of the LIRR. At this time we take "No Exception". However, Nielsen, Huber&Coughlin LLC and its agents shall adhere to the following while performing construction near our Right-OF-Way. • Fouling of LIRR track includes operation of equipment or any part of equipment, (i.e. excavator arms, cranes etc.) within 20 feet From the LIRR right of way or above LIRR tracks. All parties are notified that fouling LIRR track without LIRR flag protection being present is a violation of Federal Law. • Protection of LIRR property and facilities is the responsibility of the building's Owner and his designated Contractors. • All damages to LIRR property caused by the project shall be repaired by the Owner/Contractor or repaired by the LIRR and charged to the Owner/Contractor. Should you have any questions,please contact Don Malings of my staff at 646-418-5425. Sincerely, Donna L. Dill, P.E. Managing Engineer—Civil Inspections Cc: E.Maines,P. Nebab,D.Malings;File 2015036 MTA long Island Rail Road is an agency of the Metropolitan Transportation Authority.State of New York Thomas F,Prendergast,Chairman and Chief Executive Officer SCHERER DESIGN GROUP, LLC Colleen Connolly,PE Partne/CEO Steven Krug,PE Partne/COO February 14,2023 Town of Southold 53095 Route 25 Southold, NY 11971 Attn: Engineering Department r. Re: AT&T Site Name: LI-1025 1040-B Hortons Lane G Southold, NY 11971 SDG Project#:14BECO01 To Whom It May Concern, Scherer Design Group, LLC (SDG) is writing regarding the completed work at the above-referenced site. SDG performed the Final Inspection for subject site on 12/08/2022 to confirm the work on the site has been completed ! ' in accordance with the Construction Documents,by SDG, Revision 16,dated 09/20/2017.Additionally,SDG received inspection reports and photos from contractors in relation to the construction, and had a survey completed l i+i confirming the installed location of the Generator. ;1 �iiii•, • Daily Inspection Report,by ACER Associates, LLC,issued on 04/12/17 H! 1'. • Property Survey, by D.W Hann'ig L.S.,PC issued on 9/8/22 'i. The proposed installation was constructed in accordance with the Construction Documents referenced above. As such,SDG requests the permit be closed. Should you have any questions or comments, please call me at 908-323-2513. i Regards, s Colleen Connolly, P.E. NY#087018 100 Corporate Drive,Suite 202 • Lebanon,NJ 08833 Ph:908.323.2513 • Fax:908.323.2525 Certified Woman 0 Pmed Business Enterprise 10 SCHERER DESIGN GROUP,LLC Colleen Connolly,PE Partner/CEO Steven Krug,PE Partner/COO February 14,2023 Town of Southold 53095 Route 25 Southold, NY 11971 Attn: Engineering Department Re: AT&T Site Name:11-1025 1040-B Hortons Lane Southold, NY 11971 SDG Project#: 14BEC001 ; To Whom It May Concern, Scherer Design Group, LLC (SDG) is writing regarding-the completed work at the .above-referenced site. SDG I' performed the Final Inspection for subject site on 12/08/2022 to confirm the work on the site has been completed in accordance with the Construction Documents,by SDG, Revision 16,dated 09/20/2017.Additionally,SDG received inspection reports and photos from contractors in relation to the construction, and had a survey completed confirming the installed location of the Generator. I;. .. • Daily Inspection Report, by ACER Associates, LLC,issued on 04/12/17 • Property Survey, by D.W Hannig L.S., PC issued on 9/8/22 The proposed installation was constructed in accordance with the Construction Documents referenced above. As such,SDG requests the permit be closed. Should you have any questions or comments, please`call me at 908-323-2513. Regards, Colleen Connolly, P.E. NY#087018 100 Corporate Drive,Suite 202 • Lebanon,NJ 08833 Ph:908.323.2513 • Fax 908.323.2525 Certified Woman 0wned Business Enterprise RE, NIELSEN, HUBER & COUGHLIN, LLP ATTORNEYS AT LAW 36 NORTH NEW YOE% AVENUE HUNTINGTON, NEw YoRK 11743 TELEPHONE: (631) 425-4100 FACSIMILE: (631) 425-4104 OF COUNSEL WILLIAM J. NIELSEN August 4, 2014 By Hand Building Department Town of Southold Annex Building AUG -4 2014 1 ' 54375 Route 25 ^� Southold NY 11971 - Attn.: Ms. Connie Bunch TOVVPI ?�SOUTNOLD RE: New Cingular Wireless PCS, LLC ("AT&T") Amended Building Permit Application for Public Utility Wireless Telecommunications Facility Premises: 1040-B Horton's Lane, Southold,NY SCTM#: 1000-63 - 1 - 10 Dear Ms. Bunch: As you know, we represent AT&T in connection with the subject application, which was filed with your office on July 29, 2014. As requested, enclosed please find our firm's check no. 1786, in the sum of$50.00, which amount represents the fee for an updated Notice of Disapproval. As discussed, we will hold off on submitting a new Building Permit fee check in the amount of $750.00 until the application is being processed for issuance of the Building Permit. Should you require any further information,please advise. Very truly yours, RE,NIELSEN, HUBER& COUGHLIN, LLP By: C ugh n JC:mk Enclosure RE, NIELSEN, HUBER & COUGHLIN, LLP ATTORNEYS AT LAW 36 NORTH NEW YOB AVENUE HUNTINGTON, NEW YORK 11743 TELEPHONE: (631) 425-4100 FAcsIMILE: (631) 425-4104 OF COUNSEL WILLIAM J. NIELssrr April 6,2015 BY HAND - Town of Southold Building Department FD��Town Annex Building IT�54375 Main Road APR 6 ?015 �-� Southold,NY 11971 Atm.: Mr.Michael Verity, Chief Building Inspector -T_ RE: New Cingular Wireless PCS,LLC("AT&T")—LI 1025 Proposed Public Utility Wireless Telecommunications Facility Premises: 1040-B Horton's Lane, Southold,New York SCTM#: 1000—63— 1.— 10 Dear Mr. Verity: As you know, our firm represents AT&T with respect to its proposal to construct a public utility wireless telecommunications facility at the subject premises. The Building Permit Application was filed your office on July 29, 2014 and the Notice of Disapproval was issued on August 25, 2014. As required, AT&T thereafter sought Site Plan and Special Exception Permit Approvals from the Planning Board and the Approvals are currently pending adoption by the Planning Board. We will submit copies of said Approvals with your office upon receipt. Please note that the Planning Department, during its review of the subject proposal, recommended approval of a taller 95' unipole than the 75' height originally proposed by AT&T, in an effort to allow for greater collocation opportunities. We understand that the Planning Board intends to adopt this recommendation. To that end, we have enclosed the following documents: 1. Four(4) sets of revised Construction Drawings, prepared by Malick& Scherer, P.C., Revision 12, dated April 1,2015,revised to depict the proposed 95' pole;and 2. Correspondence of David Casey, Project Engineer, Valmont Industries, Inc., regarding fall zone radius, dated January 16,2015. Please let us know what, if any, additional documents are needed for your office's reactivation of the Building Permit Application and issuance of the Building Permit. Thanking you for your courtesies,we remain Very truly yours, RE,NIELSEN,HUBER&COUGHLIN,LLP By: J. Coug in JJC/mk Enclosures RE,NIELSEN, HUBER & COUGHLIN, LLP ATTORNEYS AT LAW 36 NORTH NEW YORK AVENUE HUNTINGTON, NEW YORK 11743 TELEPHONE: (631) 425-4100 FACSIMILE: (631) 425-4104 OF COUNSEL February 6, 2017 WILLIAM J.NIELSEN BY HAND M Town of Southold Building Department R DDLS�L:�O Town Annex Building 54375 Main Road f E B 6 2017 Southold,NY 11971 Attn.: Mr. Michael Verity, Chief Building Inspector 1BUILDINGDE". RE: New Cingular Wireless PCS,LLC ("AT&T")—LI 1025 TOWN OF SOUTHOLD Proposed Public Utility Wireless Telecommunications Facility Premises: 1040-B Horton's Lane, Southold,New York SCTM#: 1000—63 — 1 — 10 Dear Mr. Verity: As you know, our firm represents AT&T with respect to its proposal to construct a public utility wireless telecommunications facility at the subject premises. The initial Building Permit Application was filed your office in 2014, and supplemented in 2015. Additionally, in 2015, AT&T obtained Site Plan and Special Exception Permit Approvals from the Planning Board. Pursuant to communications with your office, enclosed please find the following documents: 1. Four(4) sets of Foundation Drawings, Valmont Industries, Inc., dated February 3, 2017; 2. Four (4) sets of Communications Pole Design Calculations, Valmont Industries, Inc., .dated February 3, 2017; and 3. Four (4) sets of Drilled Pier Foundation Design Calculations, Valmont Industries, Inc., dated February 3, 2017. Please let us know what, if any, additional documents are needed for your office's reactivation of the Building Permit Application and issuance of the Building Permit. Thanking you for your courtesies, we remain Very truly yours, RE,NIELSEN, HUBER& COUGHLIN, LLP By: CouWn Enclosures RE,NIELSEN, HUBER & COUGHLIN, LLP ATTORNEYS AT LAW 30 NORTH NEW YORK AVENUE HUNTINGTON, NEw YORK 11743 TELEPHONE: (031) 425-4100 FACSIMILE: (031) 425-4104 OF COUNSEL WILLIAM J.NIELSEN February 17, 2017 BY HAND Town of Southold Building Department D �DV[E D ' in Town Annex Building 54375 Main Road FEB 1 7 2017 Southold,NY 11971 Attn.: Mr. Michael Verity, Chief Building Inspector BUILDING DEPT. RE: New Cingular Wireless PCS,LLC ("AT&T")—LI 1025 TOWN OF S®1TH®LD Proposed.Public Utility Wireless Telecommunications Facility Premises:, 1040-B Horton's Lane, Southold,New York SCTM#: 1000—63 — 1 — 10 Dear Mr. Verity: As you know, our firm represents AT&T with respect to its proposal to construct a public utility wireless telecommunications facility at the subject premises. Based on recent communications with your office, we were advised that the final Building Permit fee for this project was to be $800.00. To that end, enclosed herewith, please find AT&T Check No. 454, in the requested amount, payable to the Town. Thanking you for your courtesies, we remain Very truly yours, RE,NIELSEN, HUBER& COUGHLIN, LLP By: . Co ghli Enclosure RE, NIELSEN, HUBER & COUGHLIN, LLP ATTORNEYS AT LAW 36 NORTH NEW YORK AVENUE v HUNTINGTON,NEW YORK 11743 TELEPHONE: (631)425-4100 FACSIMILE: (631)425-4104 October 3, 2017 BY HAND Town of Southold Building Department Town Annex Building 54375 Main Road Southold,NY 11971 Attn.: Mr. Michael Verity, Chief Building Inspector RE: New Cingular Wireless PCS,LLC ("AT&T")—LI 1025 Building Permit No. 41352 Proposed,Public Utility Wireless Telecommunications Facility Premises: 1040-B Horton's Lane, Southold,New York SCTM4: . 1000-63 — 1 - 10 Dear Mr. Verity: As you know, our firm represents AT&T with respect to its proposal to construct a public utility wireless telecommunications facility at the subject premises. The Town issued Building Permit No. 41352 on February 8, 2017 (copy enclosed). Subsequently, AT&T determined that it would like to utilize a different generator and also slightly different supporting HVAC units. Pursuant to communications with your office, and your direction to pursue an amendment of the Building Permit,-enclosed please find the following: 1. Four (4) sets of revised Construction Drawings, prepared by Malick & Scherer, P.C., Revision 16, dated September 20, 2017. Please let us know what, if any, additional documents are needed to amend Building Permit 41352. Thanking you for your courtesies, we remain Very truly yours, RE,NIELSEN, HUBER& COUGHLIN, LLP By: hn J codgbM Enclosures 120-11 89'AVE Richmond Hill NY, 11418 C( )� ® John@dct-inc.net t� 718 502-6262 O� 718 502-6691 Digital Construction Tech,Inc. Tuesday, February 21,2023 Site Name: LI-1025 Site Address: 1040 Horton Ln,Southold NY 11971 Block: 1 Lot: 10 Building Department, Please receive this letter as a formal request to close the permit No. 41352 for the construction of a new AT&T cellular site for the above address. As per building department clerk, we have completed and pass all necessary inspections and the only requirement left was a professional engineer letter included to in this folder. If you have any questions, comments or need additional information,do not hesitate to contact me. • /Z THANK YOU Aocr- MIRIAM MERCHAN Project Closeout Coordinator I Certified Minority/Business Enterprise miriam@dct-inc.net Digital Construction Tech. Inc. 120-1189th Ave,Richmond Hill,NY.11418 Office:718-502-6262 Ext: 108 Cell:917-808-8143 • New Cingular Wireless PCS, LLC ("AT&T") ' Cellular Coverage from Surrounding sites without proposed site LI-1025 411� "1461W . Proposed Site • On Air Sites 4hatie nLn -75 dBm + �' r El -85 dBm _ v� Ln ® -95 dBm J�'2 � �s stare H. 114 �` P� .,0�!✓.1% 4 Acle � i�,• a ,. ;v *Lw' �Q� } Rocky Ave .� .�' ,a 10 L r ala ` 2 ake r �� � ,. miles 0 Ilk d�ja�, Ca111'�r 9� _air v , tis Li �Ln a a 1 �,�„ •MAI New Cingular Wireless PCS, LLC ("AT&T") ' Cellular Coverage from Surrounding sites with proposed site LI-1025 at 62 ft ;. Proposed Site ? f y � . On Air Sites � P� o i 5hadenLn -75dBm � r 0 -85 d B m � -95 dBm �'�,P -� o state Hi 1 t4� j`•� -p , ade �o #cod p� c� " ,*•L� d + '� ■ f4F }+ fl oo Rocky oint Ave � � ' • s� -eke r �/ ■ �� •^ , miles e, + ' ' � a . otioi Ar , JOS. r f ke �t 229 n N Qa l J a o ' � New Cingular Wireless PCS, LLC ("AT&T") Cellular Coverage the proposed site LI-1025 at 62 feet •• Proposed Site tf►� ;.' 225¢ �• `' G3 � On Air Sites CN rt -75 dBm =' ' Me+tad E:1 -85 dBm "� -95 dBm 114 t =�� '� V1lrlfie�e Ave IlkFerry Rdz TO Ir 0D ay _ a s Air d Lake or a r n. �. 0 0.5 1 h �. "222 x. miles �c�i W 1E iyr.t c� ° `z A + 1 ass} CL n New Cingular Wireless PCS, LLC ("AT&T") ' PCS Coverage from Surrounding sites without proposed site LI-1025 �. Proposed SiteV I! On Air Sites Bnl -Ir -75 d ° -85 d B rn o�, i'� � - v -95 dBm C, r, S' Q ,Kati State Hi gh%vau 914 ` ;,f'- •` �� +� y0 d' jX ', ��• Q � 1 8 �r fi �s erin cs / M ro - R c k y -'+{lam 04 cep L rrko n e9 t p /Ln v`, tP C'? L CD _ of �rtY Ln a 0 • New Cingular Wireless PCS, LLC ("AT&T") ' PCS Coverage from Surrounding sites with proposed site LI-1025 at 62 ft . Proposed Site ► • 9+'` " 225 � � Q'l•Or • On Air Sites Menhadent -75 dBm o - 0 -85 d B m -95 dBm M � ,� f c State Highwayli4 Ar ' � � -` fir.,• .-P �` Rockyve p gyp ► %1025 . aQ. �� �° - r� i tdf ! milesert i!► " d 3 C? c' �'— '` 229 � 4,�j,�M.e •� ,� ��t% !sem c! -� New Cingular Wireless PCS, LLC ("AT&T") ' PCS Coverage the proposed site LI-1025 at 62 feet • Proposed Site V 22 5Q • On Air Sites x ` -75 d Bm 0\6`a'a�O o N mss° !AoI Menha� ,. -85 dBm .0 ° � � a y� D6 "0' ,# -� N -95 d B m .; 4"� �e tie ��' - R te Hi way , M IL r ,t, Wade d g ■ '�" �7� ��es ' WJfiehe qve �Sr" 0" FerrY Rd2 'v ey. i y . Rocky 'st Ave a 0 0 v:- 2 a ` ^ �(` T ° � p L1�025 ao. its p �_ d�Q �Rd Ward g± ° Lake t)r r a v �o� ` d f o o.s � l �orYadRd }. J miles ¢ n toy r' r lip Ln =•or `' '4' � rr 7 ` �. 4 hi' r �„� � / o o �J►�i Rte. _ n. ,,, Vicinity Map i .r,]•:te.a;y, �'-yp,,... `/ fPre`fit-,�? Chorners N/F V J o �•�-''' +P"-"'-' S1TOJ:TOE pavd SJt0'06'12 E State Pic— 626.24'Dved .,.`�r"� n ". h.?--fir4';j coop;•.�'. ..:-�� s,N F " '�• 'N .. '` 1 j'71•' R'1 B,lilding B per Zoning Resolutx One Story Metal Storage Buildg Area 21,7241 Sg. I 8 y Legend of Symbols & Abbreviations a.... ❑ om a� a �' a- Lot b.,O II j i N ° Lot Area O IRON PIN FOUND O MANHOLE 4y # I I € O LIGHT POLE O GAS VALVE o 6.94+- Acres ❑° Iuw'r�v^ svm \ ❑ CATCH BASIN O POWER POLE eve , rra••"•+,yV 302,481+- Sq. Ft. Z O MONITORING WELL ,~r OVERHEAD UTILITY UNE e LL -F- FENCE Parking Spaces g p �. m.❑ a4 ea ° 1; H S g o 2,-; 2 Handicap Space $ ^1 �+R ... nI W s on d mMm`"° a inns =Q sm::❑ Ir ~ 85 Regular Parking Spaces II § W s"° ❑ a - a - In a� c 100 Parking Spaces TotalIS O§ ? �;'° Z� �'^°•a a aIN N3 a^ a rn Om m a Mt• U .. N _ a m rw.a I N O am J �a m9 &_ SII rte y E a C Site Data Landscape Coverage Area: 44,018 sq.ft. 14.55% :° ❑ ,� _-- rl In om ,..-❑ I Building Floor Area: 70,445 sq.ft. - 23.29% -'-' a Lot Coverage - Buildings, Pavement etc.: 258,463 sq.ft- - 85.45% Z-2. Ea p4� a y ret•" •'• }' d •""• c•'�°^' sa,m NJIW State Pic- 26123'Deed 8 One Satory wva4 eu;ldnq 6E <,.� NfY22'2240OOW Dead Wd eldq,gree 0z0-p Had-N/F V )v o wdq.He;",.SOS, R. S p 6 One e g nares sn.¢, i g tAeo --IIdj aS2 a 15 yr{• O4.e 8 rw. Bldq.gree'gldb_g o a E B41q.NeyM1t.e04t Sq FL 8 I 24.0'; y e �•�3'a ouwvw ,v4 �."",❑ sever .v... a s.,x. xivr A For Buildings Labeled A-E see Action of Zoning Board of Appeals a"" a„• g a.e 4ep"'° R Appeal No. 3560-SE August 6, 1987 for Building Setback Requirements Nl 1'4)'4 07y 0ny ='�' =° __ o.'"ke wxa,• .a..• "°'° yz ti Bearings and Coordinates to New York State Plane - Long Island -- e•r•_- are a,a, tel ' Elevation Datum - NAVD88 a P.O.B. _ porta s La - ® w (Public ne ----- Street - Width Varies)) Pt. of the Town of Southold Suffolk Co., N.Y. p 20 40 60 u The underground utilities shown have been oco blled from field c rvey information end existing drawings. The surveyor makes n guarantee that SCALE 40' In my professional oPinlon,and based o my observations and/.r the underground utifties shown comprise all such utilities o n the o TAT cope of s rn n.^hereby cert;fy this was made(romp o N either in service or abandoned. Tho surveyor further does at woreanl 77��..��N�7M�T'� actual s rvey o of and this In.,, rect. H}oaf eve C r D.W.i1L 11V1V1G L.S.,P.C. that the underground utilities shown are in the exact location January t4,10,o FLOOD NOTE: Rev'd 2/2/10-Bearings only $URV$]`QtL9-PLANNERS-CAr13LJLiAN73 i B graphic Plotting indicated aIthou h he does certify that the By grap p g only,This property is In Zones) 9 y y era located as accurately Rev'd 9 09 14- sre (Na Oesianalion) of the ndatl Insurance Rate MOP.Community Panel No. as Possible from inlDrtnation avviloble. The surveyor hos not / / nified,o on^y 7H8 RTARIt]A'PL1($aUIIDQ4ayl __ __ 36f OJC0158H ,which bears n ellective date al Rev'a 9/07/2022-Generator o ly :(3I5)U2-=-FAX'(3J10f pAVlO WILLIAM HANNI P.Ls.,-N.Y.S.LIC.N0.4]M1f f e 09 25 09 and is physically located the underground utilities-Underground Fadbties PHONE:(71�6�372S-PAX(31�6BL7774 tvp net.n a SDecial Flood Hazard Area. Plj eels J048775/base pl11/dw9/noel-0.sbuilt-5-7-2014 Protective OrgaNm Gan PDF created with pdfFactory trial version wmv.pdffactory com d b I I r REINFORCING STEEL SCHEDULE ►45'SPACING FROM CENTERLINE OF PIER LOCATION NO REQ'D. BAR SPC'G. SIZE CUT LGTIL TOTAL LGTIL TOTAL WT. SHAPE TO THE CENTERLINE OF BOLT CLUSTER. (4) — ANCHOR BOLTS 2 1/4"0 X 7'-0" PAD HORIZONTAL 64 N 13'-6" 864'-0" 2307 LBS. STRAIGHT DWG. REINFORCING ON DWG. Pi4 (#18J A615 GR. 75 OR EQUAL) ON A 44'0 B.C. PIER VERTICAL NOTED SEE REBAR C3 REINFORCING 24ON DWG. #7 V-11" 166'-0' 339 LBS. DETAIL PIER TIES B ONODWG. #5 15'-8" 125'-4" 131 LBS.TOTAL R AR Wr. 2777 LBS. C1 i 0 I-7 r Ff TIES TO HAVE 20-f 10' HOOKVERLASHOWN3/4" T; 2'-6' 2'-6' II✓Ifs U u 5'-0' TOP & BOTTOM TEMPLATES 5'-9" �I VERTIC L PART NO.: 157163-9001 REBAR DETAIL "A" PIER TIE HOOK DETAIL GENERAL NOTES: PLAN VIEW 1..ALL ANCHOR BOLTS AND VERTICAL REINFORCING BARS ARE TO BE SECURELY TIED BEFORE (4) — ANCHOR BOLTS 2 4"0 X 7'-0' (#IBJ A615 GR. 75CONCRETE IS PLACED SO THEY WILL REMAIN PARALLEL TO THE CENTERUNE OF THE PIER. TEMPLATE OR EQUAL) W/(5) GALV. H.H.N. & (2) GALV. FW. EACH•AT TOP 2. THE GROUND ELEVATION SHALL BE A MAXIMUM OF 6" BELOW THE TOP OF THE PIER. 3. ALL EXPOSED CONCRETE CORNERS ARE TO BE CHAMFERED 3/4 INCH. (8) //5 HO A 4. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 DEFORMED BARS. 1 WITH 0 (2) WITHIN TOP 5" OF CONCRETE 5. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4500 PSI, IN ACCORDANCE WITH ACI 318-11. — 6. REINFORCING STEEL TO HAVE A 3" MINIMUM CONCRETE COVER. _ _ 7. FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL REPORT BY ACER ASSOCIATES, ¢ _ III PROJECT NO. 20150006, DATED MAY 8, 2015. I-III—III — I—E—II� 8. ANCHOR BOLTS 2 1/4"0 X 7'—O" (#18J A615 GR. 75 OR EQUAL) ON A 44'0 BOLT CIRCLE (4 REQ'D). /� �� \ II i IIII _ 1IIIIi i lI 9. CONCRETE REQUIRED 14.52 CUBIC YARDS. D 1 10. SEE THE GEOTECHNICAL REPORT FOR COMPACTION REQUIREMENTS, IF SPECIFIED. 11. THE FOUNDATION IS BASED ON THE FOLLOWING FACTORED LOADS: MOMENT(KIP—FT) = 779.38 0 `i < AXIAL (KIPS) = 16.11 0. (24) 7 VERTICAL 0 SHEAR (KIPS) = 13.23 jJ REBAR EVENLY = o 12. 4.5 FT OF SOIL COVER IS REQUIRED OVER THE ENTIRE AREA OF THE FOUNDATION SLAB. � SPACED w GO UNLESSOTHERH75E SPECIFIED MATMAL• o ALL nlM w _ ALLIANCE COMMUNICATIONS CABLES INC NO ARE ARE IN INCHES� FINISHES AM NLN r r — TOLERANCES: FRACTIONS 3 1716' 5abPE IndUStP1ES' ANGLES±-12,DEG. TOLERANCES DO NOT APPLY Towers and Poles LI-1025, NY TEMPLATE DECIMALS 3':010' TO RAW MATERIAL ' CONFIDENTIAL 95.00 MONOPOLE This document and the Mormation contained herein Is the confidential trade Is. .l property of S°bre Communlcatlons SIZE DRAWING NO. REV (16) j�8 HORIZONTAL REBAR 3" Corporouon('Sabre')and must not be JOB N0. 157163 EVENLY SPACED EACH WAY reproduced,copied or used,In whole or to DATE 2/27/17 B 157163—F1 TOP & BOT. (64) TOTAL �p ltimmon�euoo RA the Prior DRAWN BY DLK ELEVATION VIEW DATE R CHK DESCRIPTION 02017 sabre Communications Corporation SCA LE PAGE All ri to reserved CHECKED BY WJ None 1 OF 1 i lea. NOTICE: ALL PARTS ARE TO BE INVENTORIED AND ANY SHORTAGES urcAa ° REPORTED WITHIN 48 HOURS OF DELIVERY. SHORTAGES REPORTED AFTER THIS TIME PERIOD WILL BE CHARGED TO THE CONTRACTOR. CALL 800/369-6690 ASK FOR THE CONTRACTS DEPARTMENT DRAWING LIST MONOPOLE ERECTION 157163—MM o MONOPOLE FOUNDATION(S) 157163—F1 ACCESS PORT ®3'-0" 157163-F2 ORIENT POLE W THE FIELD TO SUIT MONOPOLE FABRICATION 157163-01 TIA—GROUNDING—KIT—MONOPOLE C30150110 BILL OF MATERIALS BOM-1 a•. ACCESS PORT ®9-0" ORIENT POLE IN THE FIELD TO SUIT 18C (4)2 Ile#BOLTS A K'/B.C. M FACTORY APPLIED PAINT. �- I Or i ACCESS PORT ®11'-0" ORIENT POLE IN THE FIELD m STAT � I R ♦ DOLT INSTALLATION DETAILS 1. INSTALLATION OF BOLTS: BOLTS FOR TOWERS AND ANTENNAS SHALL BE INSTALLED.WITH THE NUTS FACING TO THE OUTSIDE X I EXIT PORT AND/OR TO THE TOP OF THE TOWER, UNLESS PROHIBITED BY LACK OF CLEARANCE .. % I i 2. TIGHTENING OF BOLTS: ALL HIGH STRENGTH BOLTS SHALL BE TIGHTENED TO A SNUG—TIGHT CONDITION,AS DEANED BY AISC. BOLT FOR 3.NUT LOCKING DEVICE ALL NUTS SHALL BE EQUIPPED WITH SOME TYPE OF NUT LOCKING DEVICE SEE THE INDIVIDUAL DRAWINGS rl'-o NAME PLATE FOR THE TYPE OF NUT LOCKING DEVICE TO BE USED.FOR EACH INDIVIDUAL APPLICATION. umums GTHu e1S s�>Ea YA SABRE NAME PLATE ,■asp o N ., ALLIANCE COMMUNICATIONS CABLES INC ANCHOR BOLTS T»LDMOM 1RA=s*1ne- Sabre Industries' LI-1025, NY ANDES 3 I/1 DEa MERAlIMM DO NOT Towers and Poles DIALS!.ala' APPLY To RAW NATERAL ' 95.00 MONOPOLE LEVELING NUT This DDeumen an he n(orrnation contained herein Is the confide tial trade •.:v . ,...,`'' �..�' •.. CONCRETE ttttet prop at re Communication y� DRgDE6 N0. li1CV FOUNDARON orpor aba re and must not be 70H 157183 m educed coped or used h without or'I Dao z zv L7 B 157163—MM 0 ,for•ony purpose without thePOLE ELEVATION BASE INSTALLATION z�5 Sabbre'�cmm`D�i s°CaryO°al{onn.�� LK BCAii pAOE DAIS DEswrRaNNlt-rt I i s e er a ®®8! W7 1b7163—E N.T.S. I v 1 111111111110 11111111111111111111111111 SIIuLIE NOTES: C30150110 TIA-222-G GROUNDING HIT FOR MONOPOLES 1. MONOPOLE AND ANCHOR BOLT QUANTITY SHOWN TYPICAL ITEM QTY. PART. NO. DESCRIPTION WEIGHT 2. THERE SHALL BE A MINIMUM OF (3) GROUNDING ELECTRODES INSTALLED SYMMETRICALLY 1. 6 C30096006 GROUND ROD 5/8 X 10--0 GALV. STEEL 64.8 AROUND THE BASE OF THE STRUCTURE AT A MINIMUM 20 FT. SPACING. 2. 6 C30097008 GROUND ROD CLAMP 5/8(HARGER 302UGRC OR EQUAL) 0.8# 3. ALL BENDS IN GROUND WIRE TO BE WELL ROUNDED CURVES FREE OF KINKS, TWIST, ECT. 3. 3 C30093000 GROUND LUG BURDY K2A26U OR EQUAL) 0.6# 4. 6 C30095103 WIRE, 2/0 STRANDED BARE COPPER 25 FT. 61.8# 5. 3 C40012003 BOLT ASSEMBLY, 1/4 X 1 S.S. 0.3 TOTAL WEIGHT 128.3 MONOPOLE 2 (SHOWN TYPICAL) 1 5 3 4 o� A 3 CONCRETE FOUNDATION 40 =0 5 (SHOWN TYPICAL) MONOPOLE GRADE ;< c (SHOWN TYPICAL) •r:.. I I I 2 I LU C3 v-0• I -11 w MIN.) z 1 ELEVATION VIEW PLAN VIEW UNLESS OTHERWISE SPECIFIED MATERA1. ALL DIMENSIONS INCLUDE FMSHES AND ARE IN INCHES TOLt7LWCES.FIV=GNS 1 1/18• Sabre Industries' TOPER GROUNDING HIT ANGLES is 1/2 DED. WLERANCEs Do NOT APPLY Towers and Poles PER TIA-222-G SPECIFICATONS DECIMALS f.010' TO RAW WITERNL FOR MONOPOLES CONFIDENTIAL This doeummt and the Information can—od herein Is the eonlldenU.trade asaret property of sabre Communications SIZE DRAWING NO. REV Corporation('Sobn�)and mu.t not be repruducad,copled or used,In.ho[.or In DATE 12/7/05 B 030150110 1 part,for any purpoee■itluwt the prior A.FUSED Vffl%im ■nttm conamt of Sobra. DRATIN HY MLC SCALE PAGE 02014 Sabre Comrtwnicellons Corpaatbn None 1 OF 1 REV DATE H DESCRIPTION All rihts reserved. CHBCm BY WMN PC=PIECE OR=ORANGE CUSTOMER : ALLIANCE COMMUNICATIONS CABLES INC PLT=PALLET WH=WHITE BDL=BUNDLE 0/W=OR&WH Sabre Industries SITE : LI-1025, NY CRT=CRATE N/R=NOTREQ'D Towers and Poles D=DRUM SP=SPECIAL B.O.M. 95 FT. MONOPOLE Bx=Box PACKING ITEM NO. DRAWING PART TOTAL z QTY PKG. DESCRIPTION WEIGHT ¢ KIT OF NO NO. REQ D. NUMBER REV NO• LBS. a PKG'S 1 ANCHOR BOLTS AND TEMPLATES 2 2 157163-9001 ANCHOR BOLT TEMPLATES(W\44"BOLT CIRCLE) 143 3 4 C40041007 2-1/4"X 7'-0"(ASTM A615 GRADE 75)OR EQUAL 484 4 SECTIONS 5 1 MR1571630110 34'-0"TOP SECTION W\BASE 4923 G/P 6 MOUNTS 7 1 Z10101604 SPECIAL CANISTER 8 GROUNDING 9 1 C30150110 TIA-GROUNDING-KIT-MONOPOLE 128 10: MISCELLANEOUS 11 5 C30136001 11"X 26"X 0.1875PL ACCESS COVER(GALV) 81 SP 12 1 C40068001 130Z CAN OF COLD GALV SPRAY 1 13 1 CS00500 NAME PLATE 1 14 1 PT00000 PAINT,COLOR TBD 10 15 16 17 18 19 20 DATE 2/27/17 JOB NO. 157163 DRAWN BY DLK PRINT NO. BOM-1 REV DATE DRW CHK DESCRIPTION CHECKED BY WJ PAGE 1 OF 1 Q�BOfIOLI 6 SECIIOLI To 3rAT0 OA SRAdaT le-SOED POLE UST OF MATERIAL TA me N ®�OIDa OF SUSS BAR LUG 5 fall OTY WK NO I WTum TvuWT I 1 1 13ne3-mlo naE 1Ir:3500.$W.3 Nn-e] 31D1 z 1 Isne}5001 SA4 MiC 1] . 4130 Sri M1ln-'A sx J 71 fl 171OJ1e TOP t •1 t ASLO t0 1 /, ♦ /13ndY5002 IfP FI.VIQ MlE x n J 6Il AST1-60 SSP t 1 T ON�A It/i•P f�� '1 ym �'.MILD F :H t x{x 3 Oagl116Ja6 -57 Sao i e 1 ASS y tE]DIe ♦n7 SL0lCnld BAD(tElaR: 4n7 I t 01P LOME HIM 1 + y ales 7 °clm]east 1 x m x Slav Afra59 aawD GL M]e n I (` e 1 tD01]alto 71A-0ta0(0 -MT-YalaVE — IUD P 1 GODeBaol 13m DW OF 03D q v SPRAY — a a, FLANGE PLATE FABRICATION k, t°1/e•P m t olmm xAla LUTE — , FLAT LABELING DETAIL TOLERANCE NOTE _ RANGE FLATS AAE m BE lE1®PaPoaaEAR i m T/a Ness a nes POE m Cllwl(+)m(-)t/° I py(5 1•R TTP. 7YP.O ei'IDY m TAO iter m W1®l�Yad 16 ' S/I6 EA.SPOKE D —SEE FLANGE PLATE NOTE FABRIGDm FACTORY APPLIED PAINT. TOLERANCE NOTE 1 TYP.0 5/le G WOKEI D�� OFLANGE PLATE DETAIL • a, uw.-t• 157183-5002 _ DEL ' '�m.Ex�Tr Im(44AI1 �•�fe7so�-{ �z�� rawc 1� wATL I A Ixb P as ]I.Itr m m7(aR �P 10 II AeyT / e 12 tx aaoSTw. Y COT PORT 41.300 ! 7 I t] S\ ACCESS PORT DETAIL PP— —aav S IEa I/4 1W. 1 I! h)REEL \♦ Is,/ ] i 1 1 uv azo• •� a 1� to a130 DM a, IDG• ma To EVE fd FINN 0A4 0, m RATS 4,106!IS t I Im$ 1 P x 1-t�f A3ee »m nBAtrtxa tx1ePED0 PDa a I GROUND LUG ANGLE WELD NOg1B0L i xur 9D• -- 270• ztt n yp � S 1 I 7/IfIIKIE ]/ICr MOLE lwF1t]M IRIT 0. inSOL VOM m aE n BASE PLATE DETAH _HAND HOLESACC®PORE DATA TATTLE TYPICAL ORIENTATION r_Num1 sW loo4r !! 2 wTTxa 7 a s Tar x zs•POR m RAT t rLMARK: MWS00004 s clm]eoaa Io 1 as 1 4 J 4 A3n-ns i w i1.Rid BOTI1M ar POLE UNLESS OTNEIMSE SPOID W7E7DAL• s tlr x a]•PORT m PL o-5 Ism �0°�',,,D ARE , ALLIANCE COMMUNICATIONS CABLES INC w"RO1B0 O16CQE Sabre Industries' TLtiFAANCLR FRACIe71s t 1/fe Towers and Poles LI-1025, NY AIImES t In TIxERNICfS DO NOT S 17 x 25•PORT ON MT IS I DECWALS i.015 APPLY TORAY YATE78AL UP Y�a Donal OF PMC CONTD�FNhT14T 95.00 MONOPOLE formation con oR Dram s the Is ' roparty of Sabre Communfcations oration,constitutes a trade secret srya ND. R� 1 RA "(1 CHAD as defined b Iowa Code Ch.550 and JOH 157183 ! `>-s) (') D♦-fs) shall not be r�lroduced,copied or used D� p 27 )2 B 157163-01 U POLE ELEVATTON in whole or in part for any purpose atsoeTe�without prior written conselt DB►llF HE DLK 13C= ,PAGE DALE nP noN of Sobre Communications Corporation.Cm=W Irrl g1 N.T.S. 1 1 I s 1 I I REINFORCING STEEL SCHEDULE •45' SPACING FROM CENTERLINE OF PIER LOCATION NO REQ'D. BAR SPC'G. SIZE CUT LGTH.TOTAL LGTIL TOTAL WT. SHAPE TO THE CENTERLINE OF BOLT CLUSTER. PIER VERTICAL NOTED REINFORCING 24 ON DWG. 15'-0" 360'-0" 736 LBS. STRAIGHT ASH (4) — ANCHOR BOLTS 2 1/4"0 X 7'-0' PIER TIES 17 ON TE G. #5 15'-8" 266'-4" 278 LBS. 0:51 -_� (#IBJ A615 GR. 75 OR EQUAL) ON A 44"0 B.C. TOTAL REBAR WT. 1014 LBS. PIER TIES TO T 20'OVERLAP ORHAVE 5 3/4' f TOP & BOTTOM TEMPLATES �10' HOOK AS SHOWN PART NO.: 157163-9001 IIJII 2'-6" 2'-6" u u yI VERTICAL 5'-0" REBAR (4) — ANCHOR BOLTS 2 1/4"0 X 7'-0" (#18J A615 GR. 75 PIER TIE HOOK DETAIL PLAN VIEW OR EQUAL) W/(5) GALV. HHN & (2) GALV. FW. EACH AT TOP TEMPLATE (17) #5 HORIZONTAL TIES 0 12" C/C GENERAL NOTES: AWITH TWO (2) WITHIN TOP 5" OF CONCRETE 1. ALL ANCHOR BOLTS AND VERTICAL REINFORCING BARS ARE TO BE SECURELY TIED BEFORE CONCRETE IS PLACED SO THEY WILL REMAIN PARALLEL TO THE CENTERLINE OF THE PIER. 2. THE GROUND ELEVATION SHALL BE A MAXIMUM OF 6" BELOW THE TOP OF THE PIER. _ _ n 3. ALL EXPOSED CONCRETE CORNERS ARE TO BE CHAMFERED 3/4 INCH. 4. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 DEFORMED BARS. I—III—III— 5. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4500 PSI, III—I I IN ACCORDANCE WITH ACI 318-11. I—I i I— 6. REINFORCING STEEL TO HAVE A 3" MINIMUM CONCRETE COVER. I 7. FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL REPORT BY ACER ASSOCIATES, PROJECT NO. 20150006, DATED MAY 8, 2015. 8. ANCHOR BOLTS 2 1/4'0 X 7'-0" (#18J A615 GR. 75 OR EQUAL) ON A 44'0 BOLT CIRCLE(4 REQ'D). TEMPLATE 9. CONCRETE REQUIRED 11.27 CUBIC YARDS. 10. SEE THE GEOTECHNICAL REPORT FOR DRILLED PIER INSTALLATION REQUIREMENTS, IF SPECIFIED. I I 11. THE FOUNDATION IS BASED ON THE FOLLOWING FACTORED LOADS: — — o MOMENT(KIP—FT) = 779.38 (24) #7 VERTICAL n AXIAL (KIPS) = 16.11 REBAR EVENLY SPACED SHEAR (KIPS) = 13.23 _ 1 UNLESS OMERWISE SPECIFIED MATERIAL* ------III ALL DIMENSIONS INCLUDE FINISHES AND ARE IN INCHES ALLIANCE COMMUNICATIONS CABLES INC _ TOLERANCES:FRAC110-t 1/1e• Sabre Industries' `r1 ANGLES t 1/2 DEC. TOLERANCES DO NOT APPLY Towers and Poles LI-1025, NY L _ _ J DECIMALS t.010' TO RAW MATERIAL CONFIDENTIAL 95.00 MONOPOLE T This document and the information 1 amtat pr herein b the omMmtial trade secret property of Sabre must not bona SIZE DRAWING NO. REV 5'-0'0 Corporation('sabre)and must not be JOB N0. 157163 D reprodueed,copied or used,In whole or h DATE 2/27/17 B 157163—F2 0 part,for any purpose without the prior written consent of Sabre. DRAWN BY DLK ALE ELEVATION VIEW DATEDEscRIDESCRIPTION02017 Sabre Communlcotlone Co poraum. All hts reserved CHECKED BY WJ NSCone --,PAGE— REV OF 1 I 180• NOTICE: ALL PARTS ARE TO BE INVENTORIED AND ANY SHORTAGES W-W AOL ° '° •� REPORTED WITHIN 48 HOURS OF DELIVERY. SHORTAGES REPORTED % 13 ° AFTER THIS TIME PERIOD WILL BE CHARGED TO THE CONTRACTOR. Ba• ---�---- ;°% n°• CALL 600/369-6690 ASK FOR THE CONTRACTS DEPARTMENT DRAWING LIST MONOPOLE ERECTION 157163-MM D MONOPOLE FOUNDATION(S) 157163-F1 ACCESS PORT ®3'-0" 157163—F2 ORIENT POLE IN THE FIELD TO SUIT 180• MONOPOLE FABRICATION 157163-01 TIA—GROUNDING—KIT—MONOPOLE C30150110 BILL OF MATERIALS — BOM-1 ' �^�\ SPEdLL CANSIFR B°• ' + , 270' .. I } `j U NE u APR 1 3 2017 0• ``.. ACCESS PORT ®9'-0" ORIENT POLE IN THE FIELD TO SUIT 180• (4)21/4'0 BOLTS 7� RUIL�911C�TJlrgcL'�i�y��T•e �.PNVI� OF SOU A.HOL A� Q 9 O O�� FACTORY APPLIED PAINT. .. 14 A0. $-0' �pROFESS��� I0. i ACCESS PORT ®11'-0" ORIENT POLE M THE FIELD TO SUIT X t BOLT INSTALLATION DETAILS 1.INSTALLATION OF BOLTS: BOLTS FOR TOWERS AND ANTENNAS SHALL BE INSTALLED WITH THE NUTS FACING TO THE OUTSIDE 8 I EXIT PORT AND/OR TO THE TOP OF THE TOWER, UNLESS PROHIBITED BY LACK OF CLEARANCE. 2.TIGHTENING OF BOLTS: ALL HIGH STRENGTH BOLTS SHALL BE TIGHTENED TO A SNUG—TIGHT CONDITION, AS DEFINED BY RISC. � Y BOLT FOR 3. NUT LOCKING DEVICE: ALL NUTS SHALL BE EQUIPPED WITH SOME TYPE OF NUT LOCKING DEVICE. SEE THE INDIVIDUAL DRAWINGS J&SABRE LATE FOR THE TYPE OF NUT LOCKING DEVICE TO BE USED FOR EACH INDIVIDUAL APPLICATION. UNLESS O7NFRw15E SPEa ED MATERIAL• °- ALL DOIEN90N5 WCWDE i NAME PLATE FINISHES AND ARE W WCN6 ALLIANCE COMMUNICATIONS CABLES INC HOR BOLTS TD1ERANCM ERAcnc t f/1s• Sable Industf IES" LI-1025, NY ANGLES f 1/2 DEO.TDIFAANCES DO NOT Towers end Poles DEGMAIS 3.Of O• APPLY TO RAW MATERIAL 95.00 MONOPOLE LING NUT This Documen and the information contained herein Is the confidential trade CONCRETE secret properly of�,bre Communication SIZE DRAITQTO N0. REV FOUNDATION Corporation("Sabre and must not be JOB 157163 v 11�'11 produced,copied or used,in whole or m DA78 2 27 17 B 157163-MM 0 art, for any purpose without the POLE ELEVATION BASE INSTALLATION ar written consent of Sabre.DRATfN 8Y DLK BCALE' PAGE R. DATE CHK DESCRIPTION 11017 Sabre reserved. em rved.ions Corporation.CHO=B• Wj 157163—E N.T.S.' 1 Q 1 rights reserved. REINFORCING STEEL SCHEDULE *45' SPACING FROM CENTERLINE OF PIER LOCATION NO REQ'D. BAR SPC'G. SIZE CUT LGTH.TOTAL LGTH. TOTAL WT. SHAPE TO THE CENTERLINE OF BOLT CLUSTER. (4) — ANCHOR BOLTS 2 1/4"0 X 7'-0" PAD HORIZONTAL 64 NOTED #8 13'-6" 864'-0" 2307 LBS. STRAIGHT o A5 18J A615 GR. 75 OR EQUAL ON A 44"0 B.C. REINFORCING ON DWG. (# ) PIER VERTICAL 24 NOTED #7 6'-11" 166'-0" 339 LBS. SEE REBAR I REINFORCING ON DWG. DETAIL PIER TIES 8 NOTED #515-8" 125'-4" 131 LBS. o ON DWG. TOTAL REBAR WT. 2777 LBS. o + PIER TIES TO HAVE 10,. HO OVERLAP OR 5 3/4°HOOK AS SHOWN � N n i� 2'-6" 2'-6" II✓IIS U U 5'-0" TOP & BOTTOM TEMPLATES 5-9" yl VERTICAL PART NO.: 157163-9001 REBAR REBAR DETAIL "A" PIER TIE HOOK DETAIL 7'-0" 7'-0" 14'-0" GENERAL NOTES: PLAN VIEW 1. ALL ANCHOR BOLTS AND VERTICAL REINFORCING BARS ARE TO BE SECURELY TIED BEFORE (4) — ANCHOR BOLTS 2 1/4"0 X 7'-0" (#18J A615 GR. 75 CONCRETE IS PLACED SO THEY WILL REMAIN PARALLEL TO THE CENTERLINE OF THE.PIER. TEMPLATE �OR EQUAL) W/(5) GALV. H.H.N. & (2) GALV. FW. EACH AT TOP 2. THE GROUND ELEVATION SHALL BE A MAXIMUM OF 6" BELOW THE TOP OF THE PIER. 3. ALL EXPOSED CONCRETE CORNERS ARE TO BE CHAMFERED 3/4 INCH. b (8) #5 HORIZONTAL TIES 0 12" C/C 4. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 DEFORMED BARS. WITH TWO (2) WITHIN TOP 5" OF CONCRETE 5. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4500 PSI, IN ACCORDANCE WITH ACI 318-11. i0 6. REINFORCING STEEL TO HAVE A 3" MINIMUM CONCRETE COVER. x _ _ _ 7. FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL REPORT BY ACER ASSOCIATES, =III—III-I — I-III—III— NE j. PROJECT NO. 20150006, DATED MAY 8, 2015. 8. ANCHOR BOLTS 2 1/4"0 X 7'-0" (#1BJ A615 GR. 75 OR EQUAL) ON A 44"0 BOLT CIRCLE(4 REQ'D). II i IIII _ IIIA II I C 9. CONCRETE REQUIRED 14.52 CUBIC YARDS. O 10. SEE THE GEOTECHNICAL REPORT FOR COMPACTION REQUIREMENTS, IF SPECIFIED. E FOUNDATION IS BASED ON THE FOLLOWING FACTORED LOADS: o O d MOMENT (KIP—FT) = 779.38 Of ' W AXIAL (KIPS) = 16.11 (24) #7 VERTICAL _ CD to Z SHEAR (KIPS) = 13.23 REBAR EVENLY C? 12. 4.5 FT OF SOIL COVER IS REQUIRED OVER THE ENTIRE AREA OF THE FOUNDATION SLAB. SPACEDUj o �� �� DO UN A `I FINIS ESA E I A DI � E,� 5�0 �l ALLIANCE COMMUNICATIONS CABLES INC F� T TOLERANCES: FRACTI Sabre Industries" v io TEMPLATE ANGLES t 1/2 DEG. TOLERANCES DO NOT APPLY Towers and Poles LI-1025, N 1 DECIMALS t.010' TO RAW MATERIAL CONFIDENTIAL 95.00 MONOPOLE This document and the information contained herein is the confidential trade secret property of Sabre Communications L--(16) #8 HORIZONTAL REBAR 3" TYP. ------]'Corporation('Sabre')and must not be JOB N0. 157163 SIZE DRAWING NO. REV EVENLY SPACED EACH WAY reproduced,copied or used,in whole or in DATE 2/27/77 B 157163—F1 part,for any purpose without the prior TOP & BOT. (64) TOTAL written consent of Sabre. I DRAWN BY I DLK SCALE PAGE ELEVATION VIEW 02017 Sabre Communications Corporation. DATE R CHK DESCRIPTION All rights reserved. CHECKED BY WJ None 1 OF 1 REINFORCING STEEL SCHEDULE *45' SPACING FROM CENTERLINE OF PIER LOCATION NO REQ'D. BAR SPC'G. SIZE CUT LGTH.TOTAL LGTH. TOTAL WT. SHAPE TO THE CENTERLINE OF BOLT CLUSTER. PIER VERTICAL NOTED REINFORCING 24 ON DWG. #7 15'-0" 360'-0" 736 LBS. STRAIGHT q5µ (4) — ANCHOR BOLTS 2 1/4"0 X 7'-0" PIER TIES 17 NOTED #5 15'-8" 266'-4" 278 LBS. o ON DWG. O< (#18J A615 OR. 75 OR EQUAL) ON A 44"0 B.C. TOTAL REBAR WT. 1014 LBS. PIER TIES TO T 20"OVERLAP ORHAVE 5 3/4" .� TOP & BOTTOM TEMPLATES �I \ HOOK AS SHOWN PART NO.: 157163-9001 IIJII"' 2'-6" 2'-6" D IJ VERTICAL 5'-0" REBAR (4) - ANCHOR BOLTS 2 1/4"0 X 7'-0" (#18J A615 GR. 75 PIER TIE HOOK DETAIL PLAN VIEW OR EQUAL) W/(5) GALV. HHN & (2) GALV. FW. EACH AT TOP TEMPLATE o + (17) #5 HORIZONTAL TIES @ 12" C/C GENERAL NOTES: WITH TWO (2) WITHIN TOP 5" OF CONCRETE 1. ALL ANCHOR BOLTS AND ER11CAL REINFORCING BARS ARE TO BE SECURELY TIED BEFORE CONCRETE IS PLACED SO THEY WILL REMAIN PARALLEL TO THE CENTERLINE OF THE PIER. 2. THE GROUND ELEVATION SHALL BE A MAXIMUM OF 6" BELOW THE TOP OF THE PIER. 3. ALL EXPOSED CONCRETE CORNERS ARE TO BE CHAMFERED 3/4 INCH. c 4. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 DEFORMED BARS. I-I I I II I I II I II I-III—III— t G 5. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4500 PSI, , I I—I I IN ACCORDANCE WITH ACI 318-11. 6. REINFORCING STEEL TO HAVE A 3" MINIMUM CONCRETE COVER. 0 * 7. FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL REPORT BY ACER ASSOCIATES, Q PROJECT NO. 20150006, DATED MAY 8, 2015. W 8. ANCHOR BOLTS 2 1/4"0 X 7'-0" (#18J A615 GR. 75 OR EQUAL) ON A 44"0 BOLT CIRCLE-(4 REQ'D). TEMPLATE ( ° 9. CONCRETE REQUIRED 11.27 CUBIC YARDS. _ 10. SEE THE GEOTECHNICAL REPORT FOR DRILLED PIER INSTALLATION REQUIREMENTS, IF SPECIFIED. o { = 11. THE FOUNDATION IS BASED ON THE FOLLOWING FACTORED LOADS: �► MOMENT (KIP—FT) = 779.38 F 9 AXIAL (KIPS) = 16.11 7VERTICAL — �sFO S\O�Q' 1 �1l SHEAR (KIPS) = 13.23 REBAREVENLY SPACED I PROFES UNLESS OTHERWISE SPECIFIED MATERIALI— —I ALL DIMENSIONS INCLUDE FINISHES AND ARE IN INCHES ALLIANCE COMMUNICATIONS CABLES INC J TOLERANCES:FRACTIONS t 1/16' Sabre Industries- ANGLES t 1/2DEG. TOLERANCES DO NOT APPLY Towers and Poles LI-1025, NY L — — I DECIMALS t.010' TO RAW MATERIAL J CONFIDENTIAL 95.00 MONOPOLE This document and the Information contained herein is the confidential trade secret property of Sabre Communications SIZE DRAWING N0. REV 5'-0"0 Corporation('Sabre")and must not be JOB NO. 157163 reproduced,copied or used,In whole or in DATE 2/27/17 B 157163-F2 part,for any purpose without the prior written consent of Sabre. DRAWN BY DLK SCALE PAGE ELEVATION VIEW 02017 Sabra Communications Carporatian. REV DATE D CHK DESCRIPTION All ri hts reserved. CHECKED BY WJ None 1 QF 1 BOTTOM OF SECRON TO STAND OFF BRAaa:T IB- SO POLE LIST OF MATERIAL TAPER-M INIFT fl-F a C-UNE OF BUSS BAR LUG 6• HEW Ott 10RK NO. DFSaWMN YAIEWAL R➢41T 6-1'R I 1 15716}-0110 LUBE 1 4'a JR00 a -0' IST2-65 5161 180' 2 1 15n65-SON BAff&1 NOVI J 4•. 41.So'sa As72-50 554 ] 11R LT/W18 MT14 x11 — ID a 1 4 1 i5T8J-SD02 TOP MN0.MlE S%37 318-OA As]2-- 069 1 (12)l 1/4.0 HOLES S 5 CJNJEO05 ACQ.4 PATI 10 1 X n 1 %C%314-)M2NNR N S A-ST2-65 000 7 1 ON A 19 1/20 B.C. 6 J YYFlJ00o4 OVOIIND LVO ANGLE A-36 J 6 1 AS410LY W➢GH➢ 4717 BP 270' SIRUCNI✓E BUIX NOGHR 4717 5 16 9CP IDOSE Y6( ] 1 3/4.0 7 5(10106001 IID'X 26.0'X 018]511 ALXPM COVER Gk A-]6 n 1 8 I CJOISNIO M-fRNMOWC-NIT-YONOPIXE 128 9 1 C{0o680N —CAN OF CNO GLLV SPRAY — 2 FLANGE PLATE FABRICATION16 1/8'O 10 1®D5oo NANE MTE 1 ° TOLERANCE NOTE FLAT LABELING DETAIL nAxce PLATES ARE To BE Bn➢Eo PERPENDILIAAR TD THE AT(5 OF THE POLE TO WI➢CN(+)OR(-)1/8 +� DEGREE PP.® 6FDIIDN D iAC NOI®L iD Wit11 1118&YAR%N0. 5/16 EA.SPOKE —SEE RANGE PLATE NOTE: FABRICATION FACTORY APPLIED:P TT TOLERANCE NOTE Y.o 5/16 EA.SPOKE OF�157163 5002DETAIL 12" :PO.RT E/B BE WALL A 44.M00°B.IIY ON CENTERd10 a 12 41.500• % 7 I ly •\ r % a ACCESS PORT DETAIL 90— _ _ _ -27o- 4F?/ 090 0' V 6 1�• 1/4 -' j j 5 (2)REQ. sF�An0FESS���P l l �L 5 I 90' 2 1 1 18 / i 25500•NA. 0 180° so• SDP 1D POLE 1'-6'FRCP BASE ON MTS A 10.h 16. 1 I n xDTF� 0' " REPSii 10➢RNGSr.a026PE0 POR r' 4•X 1-I/Y ASBB MONOPOLE ED GROUND 111aD DFTAIL4 GROUND LUG ANGLE WELD ANWOfl B0.T I 'dAa wG 13AR NUT X �upe P. 90• �-- } 270' IIY 214• WASHER Rig —I--- 8 � IS 8 t I T/16v xaE T/1e•F xaE `w�wERG Nu �f I D. ZZ IRS m Paa ABASE PLATE DETAIL HAND HOLES IIEu PART xumFAA CESS IPOFrr WIOFr D DATA ABLE YATFAUL SPEC TJX TYPICAL ORIENTATION 11-0 5 10•X 25•PORT ON MT 1 MARL]. MWS00004 s r�NJ8W5 101 TS I/Y 4' 3/1 A-572-65 z IIP itFROM BOTIOY OF POLE 6 UNLESS OTHERWISE SPECIFIED MATERIAL• B_0 5 10'%25'PORT W PL 16,14-15 FINISHES ME IN INCE s ALLIANCE COMMUNICATIONS CABLES INC UP Y Row Ballow OF POLE SBbI`E IndU5t1`IE'7 TDLERANQS FRAC IONS t 1/16• Towers and Poles LI-1025, NY ANGLE 3 1/2 DEO.TOIENANCES DO NOT 5-0 5 10'%15•PORT ON Mi 10,1 DECIMALS 3.010' APPLY TO RAW MATERIAL UP s FIRM BaTRM OF POLE CON 95.00 95.00 MONOPOLE information can alne eraAm 1s the sole property of Sabre Communications Corporation,constitutes a trade secret IOH 157163 91ZE DRAFD7zz ((M»» (MD (RAD as defined by Iowa Code 1 550 and (S-6) (1) pals) shall not be reproduced,copied or used DATE12/27/171 $ 157163 POLE ELEVATION in whole or in part for any purpose whatsoever without prior written consent DRAIIN HY DLK SC DATE K DEscRrnoN of Sabre Communications Corporation.99M— WJ N. NOTES: C30150110 TIA-222-G GROUNDING HIT FOR MONOPOLES 1. MONOPOLE AND ANCHOR BOLT QUANTITY SHOWN TYPICAL. ITEM QTY- PART. NO. DESCRIPTION WEIGHT 2. THERE SHALL BE A MINIMUM OF (3) GROUNDING ELECTRODES INSTALLED SYMMETRICALLY 1. 6 C30096006 GROUND ROD 5/8 X 10'-0 GALV. STEEL 64.8# AROUND THE BASE OF THE STRUCTURE AT A MINIMUM 20 FT. SPACING. 2. 6 C30097008 GROUND ROD CLAMP 5/8 (HARGER 302UGRC OR EQUAL) 0.8# 3. ALL BENDS IN GROUND WIRE TO BE WELL ROUNDED CURVES FREE OF KINKS, TWIST, ECT. 3. 3 C30093000 GROUND LUG(BURDY K2A26U OR EQUAL) 0.6 4. 6 C30095103 WIRE, 2/0 STRANDED BARE COPPER (25 FT.) 61.8 5. 3 C40012003 BOLT ASSEMBLY, 1/4 X 1 S.S. 0.3# TOTAL WEIGHT 128.3 / MONOPOLE 2 / (SHOWN TYPICAL) 1 i/ 5 3 4 o® 1 �= ry 3 CONCRETE FOUNDATION 4 p �p� (SHOWN TYPICAL) MONOPOLE GRADE (SHOWN TYPICAL) 2 o z o� _ m 1'-0" o w (MIN.) z 1 ELEVATION VIEW PLAN VIEW UNLESS OTHERWISE SPECIFIED WATERIAL• ALL DIMENSIONS INCLUDE FINISHES AND ARE IN INCHES TOLERANCES:FRACTIONS t 1/16" SeIbre Industries' TOWER GROUNDING HIT ANGLES t 1/2DEG. TOLERANCES DO NOT APPLY Towers and Poles PER TIA-222-G SPECIFICATONS DECIMALS f.010" TO RAW MATERIAL CONFIDENTIAL FOR MONOPOLES This document and the information contained herein Is the confidential trade secret property of Sabre Communications SIZE DRAWING NO. REV C—rntlon("Sobre")and must not be reproduced,copled or used,In whole or in DATE 12/7/05 B 030150110 1 1 7 24 06 KLE DLW CHANGED ITEM 2 WAS 030097001 part,for any purpose without the prior t: 11 Ev1sED-IGI115. will consent of Sabre. DRAWN BY I MLC REV DATE DR CHK DESCRIPTION 02014 Sabre Communications Corporation. CHECKED BY WMN Nof 1PAG OFEAll rl hts reserved. PC=PIECE OR=ORANGE CUSTOMER : ALLIANCE COMMUNICATIONS CABLES INC PLT=PALLET WH=WHITE BDL=BUNDLE 0/W=OR&WH Sabre Industries SITE : LI-1025, NY CRT=CRATE N/R=NOTREQ'D Towers and Poles D=DRUM SP=SPECIAL B.O.M. 95 FT. MONOPOLE BX=BOX PACKING ITEM NO. DRAWING PART TOTAL QTY NO. REQ'D. NO. DESCRIPTION WEIGHT ¢ KIT OF NO. NUMBER REV LBS. a PKG'S 1 ANCHOR BOLTS AND TEMPLATES 2 2 157163-9001 ANCHOR BOLT TEMPLATES(W\44" BOLT CIRCLE) 143 3 4 C40041007 2-1/4"X 7'-0"(ASTM A615 GRADE 75)OR EQUAL 484 4 SECTIONS 5 1 MR1571630110 34'-0"TOP SECTION W\BASE 4923 G/P 6 MOUNTS 7 1 Z10101604 SPECIAL CANISTER 8 GROUNDING 9 1 C30150110 TIA-GROUNDING-KIT-MONOPOLE 128 10 MISCELLANEOUS 11 5 C30136001 11"X 26"X 0.1875PL ACCESS COVER(GALV) 81 SP 12 1 C40068001 130Z CAN OF COLD GALV SPRAY 1 13 1 CS00500 NAME PLATE 1 14 1 PT00000 PAINT,COLOR TBD 10 15 16 17 18 19 20 DATE 2/27/17 JOB NO. 157163 DRAWN BY DLK PRINT NO. BOM-1 REV DATE DRW CHK DESCRIPTION CHECKED BY WJ PAGE 1 OF 1 ITEM NO. FEATURES UNIT WEIGHT ID REGO WEIGHT(LBS) (LBS) 1 1 SECTION A VALMONT 5-22 0.313" THK (A572 GR65) 5,472 5,472 2 1 BOTTOM CAGE PLATE 115 115 3 8 1.75" ANCHOR BOLT, LENGTH=5.50' A615 GR75 64 508 4 1 BASE PLATE VALMONT 5-56 1.750" THK (A572 GR50) 1,023 1,023 [NOMINAL] 1 TOP CAGE PLATE (REMOVE BEFORE SETTING POLE) 148 148 94'- 0.00" 3 GROUNDING LUG 2 6 GALVANIZING 128 128 5 3 HAND HOLE STD (9" x 241 48 144 6 3 HAND HOLE STD (9" x 24") 48 144 7 3 HAND HOLE STD (6" x 12") 22 66 8 3 HAND HOLE STD (6" x 12") 22 66 9 3 HAND HOLE STD (6" X 12") 22 66 1 POLE CAP 104 104 84'- 0.00" HOLE COORDS (INCHES) HOLE COORD Y (8 REQD) 27.25 0.00 19.27 19.27 0.00 27.25 76'- 0.00" I 10.38" TYP +0,0 X 36.00" 74'- 0.00" 9 I I 60.70"TYP 14.0"0 x 0.375" MAST I NOTES: 1. BASE PLATE THICKNESS = 1.750" 2. BASE PLATE ALLOWABLE STRESS (KSI) = 50 3. ANGLES ARE MEASURED CLOCKWISE FROM 0 DEGREES 4. MAXIMUM BOLT CIRCLE DIAMETER = 54.50" 5. MAXIMUM CAGE TEMPLATE DIAMETER = 60.50" BASE PLATE ANCHORAGE CHARACTERISTICS 64'- 0.00" NOTES: 1. FACTORED REACTIONS FOR FOUNDATION DESIGN. MOMENT 7,562 IN-KIPS SHEAR 11,769 # VERTICAL = 22,002 # 2. GALVANIZED PER ASTM A-123. 3. DESIGN CRITERIA: ANSI/TIA 222-G ADDENDUM 2 4. THIS STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING LOADING: EXPOSURE CATEGORY = C STRUCTURE CLASSIFICATION = 2 561- 0.00" TOPOGRAPHY CATEGORY = 1 WIND LOAD CASES ARE BASED ON 3 SECOND GUST AND 50 YEAR WIND RETURN PERIOD 8 A. CASE 1: WIND = 105 MPH WIND SPEED 54'- 0.00" B. CASE 2: WIND = 50 MPH ICE AND WIND SPEED DESIGN ICE THICKNESS = 0.75 INCH C. CASE 3: WIND = 60 MPH WIND SPEED D. EQUIPMENT MTG CENTROID WITHOUT ICE WITH ICE HT. HT. EPA WT EPA WT 18.0110DESCRIPTION (FT) (FT) (FT**2) (LBS) (FT**2) (LBS) x ------------------------------- ------ ------ ------- ----- ------- ----- 0.375" I 1-48" DIA X 60' CELL SILO 34.00 69.90 144.00 12000 225.00 24000 MAST 5 FEEDLINES ARE PLACED INTERIOR TO POLE SHAFT (UNLESS NOTED OTHERWISE) . 6. TOTAL POLE HEIGHT IS 35 FT AGL 7. (6) 48 IN X 10 FT CANISTERS TO 95 FT AGL 8.' ELEVATIONS'ARE MEASURED FROM TOP OF BASE PLATE (APPROX 1 FT AGL) 44'- 0.00" I I 9. POLE DESIGNED TO 135 MPH ULTIMATE WIND SPEED PER IBC 2012 10. WIND SPEED CONVERSION TO 105 MPH NOMINAL PER IBC 2012 1609.3.1 34'- 0.00" 33'- 0.00" 7 1 OF NEW 'AM 7'- 0.00" W 31- 0.001, yy 5 4 (TOP OF BASE PLATE) R F S`ONQ� 3 FEB 0 31017 2 SECTION INFORMATION ORDER PROJECT FILE ID SCALE DATE ENGR 279218 279218 1 279218 1 NONE 01/30/17 NAR) Valmont ITEM IDI LENGTH I BASE OD I TOP OD I THK I MATL DESCRIPTION 1 1 34'- 0.00" 1 48.00" 1 48.00" 1 0.313" 1 A572 65 KSI KMB DESIGN 95' POLE, SITE: SOUTHOLD, NY 279218 GENERAL NOTES: DRILLED PIER ANCHOR BOLTS (SEE SECTION A-A FOR DETAILS) 6' 0 1.Prior to excavation, check the area for underground facilities. 6' 0 2.All reinforcing shall be deformed bars conforming to ASTM A615 B Grade 60 (60,000 psi min. yield) and shall be provided by the i foundation contractor. i 3.All concrete shall have a minimum compressive strength of 4000 psi @ 28 days. The requirement for the concrete shall be as given in the cap0 A ACI "Building Code Requirements for Reinforced Concrete", ACI 316, the 71!�": latest edition. CAP=0.5' CONCRETE PIER i 9.Trowel top of pedestal smooth. -- -- --------- --------, --- --- 5.Steel reinforcement and concrete should be placed immediately upon completion of the pier excavations. Contractor shall not allow a cold joint to form in the pier. Portion above grade should be formed. REBAR TIES 12"ON CENTER DOUBLE AT TOP wlTx � _ r Temporary casing may be required to prevent caving prior to 1 ON --TT- �._� 8-1.75" DIAMETER X 66" LONG concrete placement. Bottom c C ANCHOR BOLTS ON A 54.5" BOLT 6.The ground water was encountered at 38.7' below grade during boring. Template i CIRCLE MATCHING PROVIDED TEMPLATES 7.Concrete is assumed to weigh 150 pcf. <—�B B.Estimated concrete volume = 21.5 cubic yards total. 00 20.5' 9.Design Based on the following loads from installation drawing for VERTICAL REBAR order No: 279218. FOUNDATION 6 ANCHOR BOLT LAYOUT PLAN Factored Moment - 630.1 FT-KIPS (NO SCALE) Factored Download 22 KIPS CENTER THE CAGE IN _ Factored Shear- 11.8 KIPS THE DRILLED PIER 10. Reference: ACER PROJECT NO. 20150006 DATED 05/08/2015 11. Concrete shall be placed using a tremie to the depth indicated on the foundation drawing. 23 #4 BAR TIES, 12" OC, 2 ON TOP, 1 ON BOTTOM 12. Anchor bolts to be ASTM A615, Gr. 75 ksi. 13. Ref Soils Report for installation recommendations. 22 EQUAL SPACED #9 VERTICAL BARS SECTION ) �f 20' _ ) PIER ELEVATION (NO SCALE) Reinforcement Steel Schedule Total Total J- - -- - � Rebar Rebar Bar Weight Weight BAR - Type size Spacing lb/ft (lb) Qty 8.75" Anchor Bolt Projection i VERTICAL REBAR GEOMETRY 1 Verticall #9 EQUAL 3.4 1496 22 2 Ties 1 #4 12" 0.67 1 277 23 ANCHOR BOLT LOCATION TEMPLATE ,TOTAL STEEL WEIGHT FOR COMPLETE FOUNDATION INSTALLATION = 1773# i CHAMFER 1" #9 REBAR LAP SPLICE TABLE Ref. ACI 318 SECTION C-C 04 Rebar Rebar CONCRETE REBAR PIER REBAR LAYOUT Size Grade STRENGTH OVERLAP (NO SCALE) 5,- 4" PSI INCHES #9 60 4000 42 i #9 60 4000 15 NOTES: Where vertical bars are to be spliced, splices should be staggered. SECTION A-A TYP ` O� �A�_I GRADE 60 REBAR TIES HOOK GEOMETRY*** AM ANCHOR BOLT ELEVATION ���\``�^'�'I Al 0 - Rebar ASK # 6db 9db* (NO SCALE) Size Min Length Nominal Diameter i Note: EXTREME CARE SHOULD BE TAKEN TO ENSURE THAT ALL '9 seismic Hcok Not RNd N/A N/A _ BOLTS ARE LEVEL WITH RESPECT TO EACH OTHER �Ll _ *db - Bar Diameter TO ENSURE ADEQUATE NUT ENGAGEMENT r. 0 REBAR 11E GEOMETRY *+Refers to ACI Stirrup hook detail 6db 3in min. LIJ �nAyy eZ ZV� n0 t�v Ae Description Date Hy/Ck 1111 11T1 valmontV SALEM, OR 97302T SE o Ess o2HERN1sE NOTED MAIN (503) 363-9267 DXMWSIONS ARE IN INCHES MICROFLECT FAx (503) 316-2040 TOURA TOLSRANOARE: FEB0 31017 X.-X"X/X"_ 11 By: NAB DRILLED PIER FOUNDATION LAYOUT x' - r 1/e" Check: NAR CUSTOMER: KMB DESIGN X.- -. 1/16" Date: 01/30/17 SITE: SODTHOLD ANALYSIS VERSION: 1.15 S.O.#279218 SIZE - B DWG NO.B-145362 iShe.t 1 o£ 1 wwM a I ic k 9 S C h r , P Consulting En9ineers-Constuction Inspectors-Land Surveyors Perryville III Corporate Center 53 Frontage Road, Suite 260 Hampton,'NJ 08827 Ph 908.537.5 7 . 537.1398 www. m co E SITE # ■ LI - 1 025 M Lill ._ �- 1040- B HORTONS LANE , SOUTHOLD , NY 11971 GLE F ^APER NY PROFESSIONAL ENGINEER#075376 SCOPE OF WORK: IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER TO ALTER THIS DOCUMENT IN ANY WAY. An Unmanned Telecommunications Facility Including Equipment Cabinets Located 'ns' y g SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. — —PROPOSED WORK AREA �•��� inside an Existing Building, %''"''- l I£_ a 95' Overall Height Unipole with (6) Internally / 'E , °, I Installed Antennas in Place of an Existing 40' Tall APPLICANT: ♦ '� / " " =_" 4, "`£, Ili y. Flag Pole and an Emergency Backup Generator. 401 110, *00 PROJECT DIRECTORY: Property Line F �" ,a Zn ♦ f 1 '{_ // ♦ ` ; y.; ' APPLICANT: 'M / ♦ ` 48 ``_. New Cingular Wireless PCS, LLC k ° / ♦ ♦ ♦` ` `'' 400 Hamilton Avenue / ♦ ♦ 6, = "�" ` y '``• Suite 600B White Plains, NY 10601 / ♦ ♦ 6� ti �' "~ 631-424- � ♦ � � ``'� ., 3028 _ e3yF '` `'° °=f`', ATTORNEY: °�� SITEo ;_;' . M "�" ' CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING N H MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE Re , ielsen, uber & Coughlin, LLP, `a, {� �`'` 36 N. New York Avenue, THAT THEY HAVE THE LATEST REVISION OF THE BLOCK 1 " ;g;•3 ;. h'.,j F"=. �� ,rf ;'. CONSTRUCTION DOCUMENTS. LOT 10 ♦ I ;°.� , °& t } `"' Huntington, NY 11743 f aSouth�ld ''. 631-425-4100 ° , 16 GENERATOR UPDATE 09/20/17 RS - �, SITE ACQUISITION SPECIALIST: - "'- Victoria Brennan 631-807-7836 15 HVAC UPDATE 08/11/17 CM 4g RF ENGINEER: ♦ / �� o � F{ a 14 HVAC UPDATE 04/14/17 CM /♦ ` ♦ , ,` ".J '' '.s F //µM . ' PROPERTY OWNER: ♦ / �� ',"" '", aN, _ �, ; . "''_;°' � - O _ 13 PLANNER, COMMENTS 04/02/15 LM ` ♦ ♦ , '`� AVN".""' ;�: _: _ � :� YSI XXXII LLC � S CubeSmart LP ♦ ♦ � i } UNIPOLE HEIGHT ♦ ��� °° `-; M 5 Old Lancaster Rpad 12 04/01/15 LM ' Malvern, PA 19355 CHANGE _ 11 CLIENT COMMENTS 07/18/14 SK , ecC> .:.CreetDr W. Copyri phtb and 1 19$$-2000 Micrasa#k Oar" aratiarti andlar its Suppliers. All ri hts rese rued. , SITE COORDINATES KEY MAP LATITUDE: N41003'56.10" (NAD83) NO. ISSUE OR REVISION DATE BY LOCATION MAP LONGITUDE: W74025'57.64" (NAD83) NOT TO SCALE NOT TO SCALE GROUND ELEVATION: 39' +/- (NAVD88) PROJECT TITLE: DWG. DWG. TITLE APPLICABLE BUILDING CODES AND STANDARDS LEGAL DESCRIPTION : T01 COVER PAGEDISTRICT: 1000 SECTION M 63 CONSTRUCTION DOCUMENTS SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE,AND LOCAL CODES AS ADOPTED BY THE GN1 GENERAL NOTES LOCAL AUTHORITY HAVING JURISDICTION (AHJ)FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS BLOCK: 1 LOT: 10 IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. ZONE: LI - LIGHT INDUSTRIAL RM1 RADIUS MAP/VICINITY MAP ' SITE #: LI-1025 BUILDING CODE: INTERNATIONAL BUILDING CODE(IBC),2015 AS ADOPTED BY NEW YORK A01 SITE PLAN ELECTRICAL CODE: NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)70-2014,NATIONAL ELECTRICAL CODE,AS ADOPTED BY NEW YORK SITE ADDRESS: A02 ELEVATION AND DETAILS 1040-B HORTONS LANE MECHANICAL CODE: INTERNATIONAL MECHANICAL CODE(IMC),2015 AS ADOPTED BY NEW YORK p p W A03 DETAILS W W w > W SOUTHOLD, NY 11971 A04 EQUIPMENT ROOM PLUMBING CODE:NATIONAL STANDARD PLUMBING CODE,2015 AS ADOPTED BY NEW YORK O O 1.- 0 U) A05 REFLECTIVE CEILING PLAN LIGHTNING PROTECTION CODE: NFPA 780-2006, LIGHTNING PROTECTION CODE W_ Of O a- > a a- DISTRICT: 1000 SECTI A06 GENERATOR DETAIL FUEL GAS CODE: INTERNATIONAL FUEL GAS CODE(IFGC),2015 AS ADOPTED BY NEW YORK Q Q Q (_n BLOCK: 1 LOT: 1 � M01 MECHANICAL DETAILS ENERGY CODE: INTERNATIONAL ENERGY CONSERVATION CODE,2015 AS ADOPTED BY NEW YORK E3 ZONE: LI- LIGHT INDUS'S .� M02 EQUIPMENT SPECIFICATIONS SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST APPROVED OF THE FCLLOWING STANDARDS: CONSTRUCTION MANAGER: DATE El F-1 El M&S PROJECT #: 14BEC001 E01 ELECTRICAL DETAILS AMERICAN CONCRETE INSTITUTE(ACI)318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE E02 ELECTRICAL DETAILS AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION,ASD,THIRTEENTH EDITION, E03 ELECTRICAL DETAILS AISC 360, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS SITE ACQUISITION: DATE F—] SCALE: AS NOTED DATE: 01/21/10 TIA-222-G, STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES, TIA 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS DRAWN BY: GCE CHECKED BY: CCS NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101 (2015), LIFE SAFETY CODE, NFPA 37(2002), STATIONARY COMBUSTION ENGINES ❑ ❑ ❑ AND GAS TURBINES,NFPA 853(2003), STANDARD FOR THE INSTALLATION OF STATIONARY FUEL POWER PLANTS RF ENGINEER: DATE DRAWING TITLE: ' AMERICAN WELDING SOCIETY(AWS)D1.1 (2004),STRUCTURAL WELDING CODE-STEEL INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS(IEEE)81, GUIDE FOR MEASURING EARTH RESISTIVITY,GROUND El El (TYPICAL DRAFTING STANDARDS FOR ALL SHEETS) IMPEDANCE,AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100(1999)RECOMMENDED PRACTICE FOR DATE POWERING AND GROUNDING OF ELECTRONIC EQUIPMENT OWNER/OWNER REP: COVER PAGE Existing Mn, Upper And Lower Case Lettering eLabeling Existing Features IEEE C2 NATIONAL ELECTRIC SAFETY CODE(NESC)2012 PROPOSED BOLD, UPPER CASE LETTERING WHEN LABELING TELCORDIA GR-1275 GENERAL INSTALLATION REQUIREMENTS 000, 0. PROPOSED FEATURES ANSI T1.311, FOR TELECOM-DC POWER SYSTEMS-TELECOM, ENVIRONMENTAL PROTECTION DRAWING NO.: PAGE NO.: Light Lines Represent Existing Features FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION OR OTHER REQUIREMENTS,THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT DARK LINES REPRESENT PROPOSED FEATURES iJ dig. BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT,THE SPECIFIC REQUIREMENT SHALL GOVERN. T01 1 of 14 GENERAL NOTES: f. ... l 1 . THE NOTES CONTAINED HEREIN ARE NOT PROJECT SPECIFIC. THE CONTRACTOR SHALL UTILIZE THE ALL NOTES WHICH PERTAIN TO THE WORK DEPICTED IN THIS PLAN SET. 2. THE CONTRACTOR*S SHALL CONTACT M&S TO VERIFY THAT THEY HAVE BEEN ISSUED : } . THE LATEST REVISION OF THE CONSTRUCTION DOCUMENTS PRIOR TO THE START OF CONSTRUCTION. MalicldScherer, t N 3. ALL DIMENSIONS AND INFORMATION SHOWN IN THE DRAWINGS ARE DERIVED FROM Consu/ting Engineers-ConstructionInspectors-Land surveyors LIMITED FIELD OBSERVATIONS MADE FOR THIS PROJECT. DETAILED INFORMATION WAS Perryville III Corporate Center COLLECTED FOR SPECIFIC WORK AREAS. THIS INFORMATION IS TO BE USED FOR THE 53 Frontage Road, Suite 260 WORK SHOWN ON THESE PLANS ONLY. Ham 8827Ph 908.5 37.1398 4. UNLESS SPECIFICALLY REQUESTED BY THE CLIENT OR REQUIRED TO PROCEED WITH andg om THE CREATION OF THE CONSTRUCTION DOCUMENTS, STRUCTURAL PROBES HAVE NOT m %- BEEN PREFORMED. BUILDING COMPONENT CONFIGURATION AND CONDITION NOT A OTHERWISE VISIBLE BENEATH SURFACE FINISHES, MAY VARY AND SHALL BE CONFIRMED BY THE CONTRACTOR PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES, WHETHER IN CONFIGURATION OR CONDITION SHALL BE BROUGHT ° sa TO THE IMMEDIATE ATTENTION OF THE ENGINEER. f "r GLENN J. SCHERER 5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS & FIELD CONDITIONS PRIOR TO THE NY PROFESSIONAL ENGINEER#075376 START OF CONSTRUCTION. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE IT IS A VIOLATION OF THE LAW FOR ANY PERSON, ATTENTION OF THE ENGINEER. THE CONSEQUENCES OF PROCEEDING WITH UNLESS ACTING UNDER THE DIRECTION OF A LICENSED CONSTRUCTION AFTER DISCOVERING A FIELD CONDITION DISCREPANCY AND WITHOUT ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. THE APPROVAL OR RECOMMENDATIONS OF THE ENGINEER, SHALL BE THE SOLE SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. RESPONSIBILITY OF TH N A . APPLICANT: 6. THE CONTRACTOR SHALL ADHERE TO ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES. 7. CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY PERMITS AND INSPECTIONS TOrl - COMPLETE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL INSPECTIONS REQUIRED BY THE AUTHORITY HAVING JURISDICTION, INCLUDING, BUT NOT LIMITED TO, ELECTRICAL, PLUMBING, FIRE PROTECTION AND STRUCTURAL. 8. THE CONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY THE ENGINEER OF CONSTRUCTION STAGES WHICH REQUIRE SPECIAL OR CONTROLLED INSPECTIONS WITH A MINIMUM OF 48 HOURS (BUSINESS DAYS NOTICE. THESE INSPECTIONS INCLUDE, BUT CONTRACTOR SHALL CONTACT MSS PRIOR TO ORDERING MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE ARE NOT LIMITED TO, CONCRETE REINFORCEMENT, CONCRETE POURING, STRUCTURAL THAT THEY HAVE THE LATEST REVISION OF THE CONSTRUCTION DOCUMENTS. STEEL ERECTION/BOLTING, WELDING AND THE INSTALLATION OF EPDXY ANCHORS. FAILURE TO COORDINATE THESE INSPECTIONS WITH THE ENGINEER MAY PROHIBIT 16 GENERATOR UPDATE 09/20/17 RS SIGNOFF WITH THE AUTHORITY HAVING JURISDICTION. 9. CONTRACTOR SHALL PROVIDE ENGINEER WITH PHOTOGRAPHS FOR EACH STAGE OF 15 HVAC UPDATE 08/11/17 CM CONSTRUCTION. THE PHOTOGRAPHS SHALL INCLUDE, BUT ARE NOT LIMITED TO, BEAM POCKETS & PEDESTAL CONNECTIONS. 14 HVAC IUPDATE 04/14/17 CM 10.. THE CONTRACTOR IS RESPONSIBLE FOR SAFETY DURING CONSTRUCTION. THE ENGINEER HAS NO RESPONSIBILITY FOR OR CONTROL OVER SAFETY AT ANY TIME. 13 PLANNER COMMENTS 04/02/15 LM 11 . THE ENGINEER HAS NOT PERFORMED AN INSPECTION FOR ASBESTOS OR OTHER UNIPOLIE HEIGHT HAZARDOUS MATERIALS. THESE DRAWINGS ARE NOT MEANT TO DEPICT OR IMPLY THE 12 CHANGE 04/01/15 LM PRESENCE OR ABSENCE OF SUCH MATERIALS WITHIN THE PROPOSED WORK AREAS. 12.. TRUE NORTH SHALL BE DETERMINED. CONTRACTOR IS RESPONSIBLE FOR PROPER 11 CLIENT COMMENTS 07/18/14 SK AZIMUTH ALIGNMENT. 13., THE CONTRACTOR SHALL CONTACT THE TELECOMMUNICATIONS CARRIER TO ACQUIRE NO. ISSUE OR REVISION DATE BY THE LATEST RF DATA SHEET PRIOR TO THE START OF CONSTRUCTION. RF INFORMATION ISSUED BY THE TELECOMMUNICATIONS CARRIER SUPERSEDES INFORMATION CONTAINED HEREIN. PROJECT TITLE: 14,. ROUTING IS DIAGRAMMATIC AND CONTRACTOR IS TO UTILIZE BEST POSSIBLE ROUTING CONSTRUCTION DOCUMENTS TO EXPEDITE CONSTRUCTION PROCESS. ROUTING SHALL NOT IMPEDE UPON REQUIRED PASSAGEWAYS OR MEANS OF EGRESS. SITE #: LI-1025 15,. THE CONTRACTOR SHALL PROVIDE NEW PENETRATIONS FOR ROUTING THROUGH FIRE RATED ASSEMBLIES AND FIRE STOP ALL PENETRATIONS AS PER CODE. THE SIITE ADDRESS: CONTRACTOR SHALL BE RESPONSIBLE TO RESTORE THE FIRE RATING OF BUILDING 1040-B HORTONS LANE COMPONENTS IF EXISTING PENETRATIONS ARE USED FOR NEW ROUTING. SOUTHOLD, NY 11971 16., ALL DISTURBED AREAS SHALL BE REPAIRED TO MATCH EXISTING ADJACENT, INCLUDING DISTRICT: 1000 SECTION: 63 BUT NOT LIMITED TO FIRE RATED MATERIALS. BLOCK: 1 LOT: 10 17„ ANY DISTURBANCE TO ROOFING, FLASHINGS OR ANY EXTERIOR SURFACE SHALL BE ZONE: LII- LIGHT INDUSTRIAL REPAIRED/SEALED WATERTIGHT AND IN ACCORDANCE WITH ANY WARRANTIES, AS M&S PROJECT #: 14BECO01 APPLICABLE. THE GENERAL CONTRACTOR SHALL EMPLOY THE WARRANTY GRANTOR, OR OTHER AUTHORIZED CONTRACTOR, WHERE REQUIRED FOR MAINTENANCE OF THE SCALE: AS NOTED DATE: 01/21/10 WARRANTY. 18,, THE PERIMETER AND ANCHORS OF ALL STEEL TO CONCRETE OR MASONRY DRAWN BY: GCE CHECKED BY: CCS CONNECTIONS SHALL BE SEALED WATERTIGHT USING A PURPOSE FORMULATED MASONRY SEALANT. DRAWING TITLE: 19,. CONTRACTOR SHALL REMOVE TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. GENERAL NOTES DRAWING NO.: PAGE NO.: GN1 2 of 14 NOTE. `:.,. ; NO FEDERAL AND STATE LANDMARKS OR SCENIC BYWAYS ARE LOCATED WITHIN 14 300 OF THE SUBJECT PARCEL. { °h IL 4 � � - - ` ♦ 6 1 18 19 20 ' � C 2 ` Scherer, P ('l B A Tiq Bldg 9 13 1 Consu/ting Engineers-Construction Inspectors-Land Surveyors .00 C ♦ Perryville III Corporate Center Bldg 8 Section: •63.02 53 Frontage Roa Suite 260 401 0.0 Block. 1 Ham p It i 37 t Ph 908.537 0 98 i 37 36 3 ♦ 1 www. an twer. m 35 43 A 27 E Founders Village Condominiums t Z 47 46 45 44 E 0 C S E 0 C 8 A 26 A 1 /'I Section: 63.01 Bldg 12 (::EE) Bldg 10 3 BlOak: 1 Bldg 14 C ` 1 U��ii 376 r �NG�• ♦/36 30 31 321 R 29 E GLENN J. SCHERER 139 28 c ° Q a 1 NY PROFESSIONAL ENGINEER#075376 38 40 41 4 A 8 1 � 3 24 25 9.1 t IT IS A VIOLATION OF THE LAW FOR ANY PERSON, 22 A 6 C 0 E Bldg 11 21 R 8.1 UNLESS ACTING UNDER THE DIRECTION OF A LICENSED o E I ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. 8 c Id —• R , t SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. _ •�'• //�� 61 71 t APPLICANT: 1 _ • -'T/"� / / ' ^ Section: t 1 __- '•��!'�"Ti/////iii//iii/ / Block: 1 R 1 loom 1 0. ��� '- // /�1 woor ev 00 Section: 63 / / / / / r / /� •JI HB , 25.4 Block: 1 //// / / / / / r 1 t L . . Po._. ..r. ... 3.2 R — 40 moll i / / / 9.3 Q1 /////// / /////////// O , CONTRACTOR SHALL CONTACT M85 PRIOR TO ORDERING 13.2 /// ///// / 2.2 Vacant Land �; MATERIALS OR ////// // / �`� / / / / / / / / / / / i• I THAT THEY HAVEITHENLATESTTREVISOIONTOFETHERE R IT //// ///// / / / / / / / / / / / / / / / t CONSTRUCTION DOCUMENTS. 1 1 12 S E ��i/////// /// //// N Vacant Land R ///////// // / / / / / / / / / / / / / / / .� I t 16 GENERATOR UPDATE 09/20/17 RS 1 / ////// � / •,Ji / / / / / / 00 N�A� /////////// o ,cy / / / / / / / / / / / / / / 5 �. 0• 'f0 N� / / / / / / / / � - C 15 HVAC UPDATE 08/11/17 CM 131 209' ppf�R� 1�///////// / / ZONE BOUNDARY LINE (TYP) P� �1//////// / / / �+/ / / / / / y 2.1 3.1 R ES. • /// 'iii �iiiii ,/�r R Q C R 1 14 HVAC UPDATE 04/14/17 CM 11 ,•///// / / / / / / / / / / / / / / / 30.1 ` R tV// / / / / / / / / / / / / / / / / / D 15 'R 13 PLANNERCOMMENTS 04/02/15 LM 17 1R6 •i / / / / / / / / / / / / / / / / / / / � t 18 R0 UNIPOILE HEIGHT 19 12 04/01/15 LM / / / / / / / / / / / / �,,r.•�.+• 11 .1 20 R CHANGE R 14 ❑ - •.•,, -- '�". Vories) 1 r 11 CLIENT 'COMMENTS 07/18/14 SK _ _- ane � R _--- - _ �W�dth � Horton �- 8.11 ?a 13 1 R 00� R NO. ISSUE OR REVISION DATE BY 3.1 R 7 ? s. RO 000 PROJECT TITLE: R 1 t 6 y � CONSTRUCTION DOCUMENTS R � p 8.2 Rd Section: 63 R e Block: 5 SITE #: LI-1025 � Section. 63 n�(S � � Block: 1 un O i 12R1 SITE ADDRESS: LAND USE LEGEND: 1 .3 5 Vacant Land � 1040-B HORTONS LANE R - Residential `♦ 0 R , SOUTHOLD, NY 11971 C - Commercial Industrial ❑ 4 � 0 - Open Space/Residential 3.2� R DISTRI1CT: 1000 SECTION: 63 � � ` R ; BLOCK: 1 LOT: 10 O ZONE: LI- LIGHT INDUSTRIAL 500' RADIO LINE ♦ ♦♦ � ZONING LI-GEND: _ - - R1 ` M&S PROJECT #: 14BECO01 LI ! LIGHT INDUSTRIAL � �' - - - (D , •�• 31 M � SCALE: AS NIOTED DATE: 01/21/10 R-40! RESIDENTIAL LOW DENSITY AA .� 1 HAMLET DENSITY RESIDENTIAL �• � R R - 40 r� ; DRAWN BY. GCE CHECKED BY. CCS =HD - - O DRAWING TITLE:CHB ! HAMLET BUSINESS 000 000*0 R- ! RESIDENTIAL LOW DENSITY A • ❑ =ROI RESIDENTIAL/OFFICE i�� RADIUS MAP/ VICINITY MAP 1 RADIUS MAPNICIIVITY MAP DRAWING INO.: PAGE NO.: 11x17 SCALE=: 1"= 200'-0" 22x34 SCALE: 1" = 100'-0" RM1 3 of 14 NOTES: 1. SITE PLAN AND PROPERTY LINE DATA SHOWN WAS TAKEN FROM M , a A SITE PLAN ENTITLED FINAL TOPO SURVEY., PERFORMED BY D.W. HANNIG L.S., P.C. RE-CERTIFIED ON MAY 1, 2014. THIS DRAWING DOES NOT CONSTITUTE A BOUNDARY SURVEY. r 2. THE PROPOSED USE OF THE DEVELOPMENT IS FOR AN `. Deed peed UNMANNED WIRELESS COMMUNICATION FACILITY, ° M E 626,2THE FACILITY WILL NOT BE STAFFED FULL TIME. IT WILL BE VISITED NOTE: S17•43 30"E 4 FOR MAINTENANCE APPROXIMATELY ONCE PER MONTH. EXISTING FLAG POLE TO BE REMOVED State plane 4 TECHNICIAN MAY PARK NEAR COMPOUND ON TECHNICIAN Mclick9bIcherer, Put AND REPLACED WITH NEW 941 GRAY , PARKING AREA. Consu/ting Engineers-Construction/nspectors-Land Surveyors UNIPOLE ON 1 ' HIGH CAISSON ABOVE S30•p6 12 - • J • IT 3. NO SANITARY OR WATER FACILITIES ARE REQUIRED. Perryville III Corporate Center GROUND LEVEL (95' OVERALL HEIGHT) 13P 1"°`POC•° ( ELECTRIC AND TELEPHONE ARE THE ONLY UTILITIES THAT p ARE REQUIRED. UTILITY SERVICE WILL BE PROVIDED FROM 53 Frontage Road, Suite 260 ' Ham ton, NJ 08827 • - UTILITY POLE AS SHOWN. 8 4. NO WATER COURSE OR FLOOD PLAINS WILL BE EFFECTED BY Ph 908.537.300 Fax 9 0 .537.1398 • n: 63 � THIS DEVELOPMENT. www.mali er.com • / • Sects° 5. ACCESS TO THE SITE WILL BE VIA EXISTING HORTONS LANE. 5�P �" ,,. S`, N 510k��0 \ TRAFFIC IMPACTS WILL BE NEGLIGIBLE SINCE THE SITE IS UNMANNED • Lo Use 6. NO TREES/SHRUBS WILL BE AFFECTED BY THIS CONSTRUCTION. 1 Building B ornmerc�a ( 7. NO SITE LIGHTING IS PROPOSED. • 150' FALL ZONE C Lot Are°' s °' -a 8. THE CONTRACTOR SHALL ABIDE BY ALL CURRENT LOCAL, 6•gq+ Asa• Ft. 1 o STATE, AND NATIONAL CODES THAT ARE APPLICABLE. 37 , _ ` 30248� +- 9. THE CONTRACTOR SHALL COORDINATE WITH UTILITY NYPROFES ER#075376 Lo. COMPANIES AND MEET ALL CURRENT UTILITY COMPANY •o REQUIREMENTS AND SPECIFICATIONS. IT ISAVIOLATION OF THE LAW FOR ANY PERSON N ` AT&TPA 10. NO CHANGE IN EXISTING DRAINAGE PATTERNS WILL UNLESS ACTING UNDER THE DIRECTION OF A LICENSED / �6) AT& NEL Building A RESULT FROM THIS PROPOSAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. Cr ANTENNAS INSTALLED SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. 0 11. NO TRASH DISPOSAL IS REQUIRED IN CONNECTION WITH WITHIN TOP TWO RF COMPATIBLE N THE PROPOSED INSTALLATION. APPLICANT: CYLINDERS OF PROPOSED UNIPOLE 1 i . GPS DEVICE ATTACHED BuildingC �' 2 SITE PLAN NOTES . TO NEW UNIPOLE o SEE DETAIL 3/A03 J 11x17 SCALE: NTS 22x34 SCALE: NTS p / � 1 � rn 8.9 1 BRICK PLANTER AT BASE OF c, LI District REQUIRED EXISTING PROPOSED '" r o r} FLAG POLE ATO BE RESTORED o w- AFTER INSTALLATION 9" o ` OF PROPOSED UNIPOLE) 74 `, 0 Min Lot Size 40,000 SF 302,481 SF No Change _:Z1, 7 M , ' Building D CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING w • , No Change MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE 0 Min Lot Width 100 351 .93 THAT THEY HAVE THE LATEST REVISION OF THE ' ' CONSTRUCTION DOCUMENTS. Building E °o � N O •I 209' cpeff� k� I Min Lot Depth 150' 403.66 No Change.w°,k o, 16 GENERATOR UPDATE 09/20/17 RS to o ► .•: AT&T CABLING TRENCHED UNDERGROUND WITHIN = (, Min Front Yard 100' 69.0' 296'2, (F) 15 HVAC UPDATE 08/11/17 CM (8) 6 PVC SLEEVES FROM EQUIPMENT ROOM TO 257.9 (G) Q UNIPOLE. SAW CUT ASPHALT PARKING LOT AS REQUIRED. REPAIR PARKING LOT TO MATCH - , 14 HVAC UPDATE 04/14/17 CM • - peed Min Side Yard 20' 30.02' 209.0 (F) EXISTING CONDITIONS, SEE DETAIL 1/A03 AND , Property Line NOTE BELOW 61 23 129.0 (G) TECHNICIAN , Plane 2 13 PLANNER COMMENTS 04/02/15 LM F71 ate „ pe Min Both Side PARKING SPOT PROPOSED AT&T DIESEL BACKUP GENERATOR - . '22' W St 2140 W D Yards 40 60.04 627.9 ' • � N31 45 N 19 2 UNIPOLE HEIGHT ELECTRIC AND TELCO CONDUITS ATTACHED TO PROPOSED CONCRETE PAD , - 245.9' (F) 12 04/01/15 LM TRENCH17D UNDERGROUND FROM 12 P°, ,� SEE DETAIL 6/AO3 X - Min Rear Yard 70' 50.76' CHANGE SOURCE TO EQUIPMENT ROOM IN I I I I Distance From Unipole to Exist�ng 267.4' (G) C) Structures on Property11 CLIENT COMMENTS 07/18/14 SK $uILDInIG E. Saw CUT ASPHALT �. -.- AT&T 300 S.F. EQUIPMENT I , PARKING LOT AS REQUIRED ROOM IN BUILDING E UTILIZING Building A: 308.2 Min Landscaped • 25% 15% No Change REPAIR PARKING LOT TO MATCH N ,k UNITS 703, 704 9771 AND 772Area EXISTING CONDITIONS °k �°�'°'° N SEE DETAIL 1/A04 Building B: 144.8 Max Lot NO. ISSUE OR REVISION DATE BY SEE DETAIL 2/AO3 AND NOTE #2 o Building C: 199. 1 ' Coverage 30%0 23.28% 23.29% N Office for � Max Building � > PROJECT TITLE: Lawn Mower U-Store-It Building D. 74.7 Height g 35 24 95 Repair Shop ° Building E: 75.2' Max Number CONSTRUCTION DOCUMENTS ��k • N of Stories 2 1 N/A � P,d �. cv Building F: 180.8' Q • w � 1 °�° ; �°�k 1 �"�c°� � SITE #: LI-1025 �« S «° oo Building G: 181 .3' , e P°rk1rW �° o cn SITE ADDRESS: C) SITE Parking Spaces 1040-B HORTONS LANE NM 6 e P "9 SP°`O I CE _ - _ ►�^° ti 2 Handicap Spaces Wireless REQUIRED EXISTING PROPOSED SOUTHOLD, NY 11971 _ Telecommunications EQU ED E S G N ExistingMeter - - P � and Disconnects _ - P 84 Regular Parking Spaces Z. 1 °47 0 W 351 .9 °"�'°°d` Max Tower Height 80 N A 95 DISTRICT: 1000 SECTION: 63 _ 1 Technician Parking Space 9 / BLOCK: 1 LOT: 10 5 •tu", - °M� NOTE: 87 Total Parking Spaces Tower Setback: ZONE: LI- LIGHT INDUSTRIAL NEW CS1C CABINET TO BE PoN Hobane rton Nearest Dwelling Unit N A' N/A 276.7' d! P Width Varies) INSTALLED BY SERVICE (Pubiir. Street - CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES Nearest Res. Prop. Line 5 0' N/A 209.0' M&S PROJECT #: 14BECO01 PROVIDER G AM PROPOSED METER AND DISCONNECT AND SEWERS BEFORE THE START OF CONSTRUCTION. Min Lot Area 40,000 SF 302,481 SF No Change SCALE: AS NOTED DATE: 01/21/10 ATTACHED TO BUILDING EXTERIOR. IF ANY DISCREPANCIES FROM THESE PLANS ARISE, TELCO CONDUIT TRENCHED COORDINATE WITH UTILITY COMPANY CONTACT THE ENGINEER (M&S) IMMEDIATELY. FROM UTILITY POLE TO FOR ELECTRICAL CONNECTION Min Fence Height 6' N/A N/A DRAWN BY: GCE CHECKED BY: CCS NEW CSC CABINET. MaxOORDINATE ALLOW FOR 3' ACCESS COAX CABLE CHART r WITH SERVICE PROVIDER. CLEARANCE IN FRONT NO. QTY. SECTOR COAX LENGTH 8 a A ea 500 SF N/A 300 SF DRAWING TITLE: SEE DETAIL 2/AO3 OF NEW METER AND 1 8 ALPHA 170' Base Screening Yes N/A No DISCONNECT (Vegetation) / Utility Pole 2 8 BETA 170 SITE PLAN 75KVA Transformer 3 8 GAMMA 170' Tower Color Gray N/A Gray � Call betore you dig. E SITE PLAN 3 BULK REQUIREMENTS DRAWING NO.: PAGE NO.: 11x17 SCALE: 1"= 80'-0" 22x34 SCALE: 1" = 40'-0" 11x17 SCALE: NTS 22x34 SCALE: NTS A01 4 of 14 " REPLACE EXISTING FLAG POLE \ , ° WITH NEW 94' UNIPOLE ON 1 ' HIGH CAISSON ABOVE GROUND (3) AT&T PANEL ANTENNAS INSTALLED :.;. LEVEL (95' OVERALL HEIGHT) 38" WITHIN 101 RF COMPATIBLE CYLINDER Mr e r, P C"*' 95' +/— AGL DIA (TOP OF UNIPOLE) Consulting Engineers-Construction Inspectors-Land Surveyors In Perryville III Corporate Center 53 Frontage Road, Suite 260 92' +/— AGL U (3) AT&T PANEL ANTENNAS INSTALLED Ha P, e 7 (RAD CENTER) WITHIN 10 RF COMPATIBLE CYLINDER 85' +/— AGL_ Ph 908.5 ,,fi .1398 TOP OF RF COMPATIBLE CYLINDER icka ^ds he�g .co C ) ,.., ;Yl �� A 82' +/— AGL — �� I 9 U (RAD CENTER) FS oN 75' + AGL AL - TOP OF RF COMPATIBLE CYLINDER)—) GLENN J.SCHERER NY PROFESSIONAL ENGINEER#075376 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, EMPTY 10' RF COMPATIBLE CYLINDER UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. 65' +/— AGL_ SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. (TOP OF RF COMPATIBLE CYLINDER) APPLICANT: EMPTY 10' RF COMPATIBLE CYLINDER W 55 +/— AGL_ (TOP OF RF COMPATIBLE CYLINDER) hP EMPTY 10' RF COMPATIBLE CYLINDER PROPOSED PROTECTIVE CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING BOLLARDS (TYP FOR 12) MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE THAT THEY HAVE THE LATEST REVISION OF THE PAINTED CAUTION CONSTRUCTION DOCUMENTS. YELLOW 16 GENERATOR UPDATE 09/20/17 RS SEE DETAIL 4/AO3 GPS DEVICE ATTACHED TO BUILDING EXTERIOR 15 HVAC UPDATE 08/11/17 CM SEE DETAIL 3/AO3 COAX CABLES ROUTED I UP INTERIOR OF PROPOSED -J 14 HVAC UPDATE 04/14/17 CM AT&T 300 S.F. EQUIPMENT UNIPOLE I I ROOM IN 703, 704 ,7711 BUILDING I 13 PLANNER COMMENTS 04/02/15 LM UTILIZING UNITS 7 I AND 772 SEE DETAIL 1/A04 BRICK PLANTER AT BASE OFI I TO BE 12 UNIPOLE HEIGHTEXISTING FLAGPOLE 04/01/15 LM Building E RESTORED AFTER INSTALLATION CHANGE OF PROPOSED UNIPOLE) I 12'+/— AGL I 11 CLIENT COMMENTS 07/18/14 SK (TOP OF GPS) I _ I NO. ISSUE OR REVISION DATE B TOP OF GENERATOR Y .- ( ) 1 ' +/— AGL /—(TOP OF BRICK PLANTER/ PROJECT TITLE: — CAISSON) 48„ CONSTRUCTION DOCUMENTS �- - - - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I DIA SITE #: LI-1025 COAX CABLE CHART PROPOSED AT&T DIESEL AT&T CABLING TRENCHED UNDERGROUND WITHIN SITE ADDRESS: BACKUP GENERATOR (8) 6" PVC SLEEVES UNDERGROUND FROM 1040-B HORTONS LANE NO. QTY. SECTOR COAX LENGTH ATTACHED TO PROPOSED EQUIPMENT ROOM TO UNIPOLE. SAW CUT ASPHALT • CONCRETE PAD PARKING LOT AS REQUIRED. REPAIR PARKING LOT SOUTHOLD, NY 11971 1 8 ALPHA 190 SEE DETAIL 6/AO3 TO MATCH EXISTING CONDITIONS 2 8 BETA 190' SEE DETAIL 1/A03 DISTRICT: 1000 SECTION: 63 3 8 GAMMA 190' PROPOSED CONCRETE BLOCK: 1 LOT: 10 PAD (31—5"X91—4") ZONE: LI- LIGHT INDUSTRIAL (31 .62 SgFt) R SEE DETAIL 5/A03 M&S PROJECT #: 14BECO01 SCALE: AS NOTED DATE: 01/21/10 Know wtat's SOV.. TRENCH (3) CONDUITS FROM PROPOSED DRAWN BY: GCE CHECKED BY: CCS Call f t . BACKUP GENERATOR TO PROPOSED EQUIPMENT ROOM DRAWING TITLE: SEE DETAIL 1/A03 ELEVATION AND DETAILS DRAWING NO.: PAGE NO.: 1 WEST ELEVATION 0 8' 16' 11x17 SCALE: 1/16"= 1'-0" 22x34 SCALE: 1/8" = 1'-0" A02 5 of 14 ' PROVIDE WARNING GRAVEL, PAVE, OR VEGETATE TAPE ORANGE 0.1 MM FLEXIBLE NTO MATCH EXISTING - GPS DEVICEPOLYETHYLENE FILM WHICH } :g • ..s ;; 0 , r I SHALL BE RESISTANT T ACIDS,IDS. _ `. I I 11 C2 It befm rm dig. BASES, HYDROCARBONS, AND WATER. `. ;< COMPACTED BACKFILL FINISHED GRADE, OR 6" OF TOPSOIL TO BE BACK y j PAVING MATCH SLOPE TRENCH 1 1/4"" DIA NOM "' � ° FILLED ON TOP OF CONDUIT TRENCH UNDISTURBED AND THICKNESS OF AND GRASS TO BE REPLACED OR SEEDED o Sc 40 PIPE EXISTING UNDISTURBED solL N (:�N, c e r e r, r E N 1/2" DIA BOLT 3/8"X 6"X6" Consulting Engineers-Construction Inspectors-Land Surveyors COMPACTED BACKFILL CONNECTION � � W SATISFACTORY THROUGH ALUMINUM SHEATHING PLATE Perryville III Corporate Center NATIVE OR IMPORTED 5 II II II I EI I �I I I_ - 3 FrSOILontage rontage Road, Suite 260 iv = — � , . . . . . . - STANDOFF Hampton, NJ 08827 UTILITY WARNING TAPE •. ... PLATE Ph 908.537.1300 Fax 908.537.1398 • ••r r••'' ►V.. � � * • �- CUT TO wwW.malicka com „ F.... .. . •,.N " III IIS °�'V REQUIRED LENGTH TE FN,� — — = SAND FILL •�a� (2) COAX f HT( CABLES ►'� c < . c• o: r 16" SAND FILL TELEPHONE CONDUIT 3" MIN ELECTRICAL CONDUIT 3/8"X611X611 GL ✓. G��IEd * WHERE APPLICABLE a WHERE APPLICABLE / \_ * BACKER PLATE NY PROFESSI s G 075376 2" (MIN) COORDINATE SIZE, TYPE COORDINATE SIZE AND AT&T CABLING WITHIN (8) AND QUANTITY WITH TYPE WITH LOCAL IT IS A VIOLATION OF THE LAW FOR ANY PERSON, (HORIZ. & VERT.) 6" PVC SLEEVES SCHEDULE 40. LOCAL UTILITY6" MIN UTILITY UNLESS ENG NEERI ACTNG UNDER THIS DIRECT ONTOF ANY LICENSED (TYP) SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. NOTES: 1 . HAND DIG ALL UTILITY CROSSINGS. *SEPARATION DIMENSION TO BE VERIFIED APPLICANT: WITH LOCAL UTILITY COMPANY REQUIREMENTS 2. CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES NOTES: AND SEWERS BEFORE THE START OF CONSTRUCTION. 1 • HAND DIG ALL UTILITY CROSSINGS. IF ANY DISCREPANCIES FROM THESE PLANS ARISE, CONTACT THE ENGINEER (M&S) IMMEDIATELY. 2. CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES rr ' LN . . AND SEWERS BEFORE THE START OF CONSTRUCTION. IF ANY DISCREPANCIES FROM THESE PLANS ARISE, 3 CONTACT THE ENGINEER M&S IMMEDIATELY. GPS DEVICE MOUNT 11x17 SCALE: NTS J2� x34 ALE• TS CONTRACTOR SHALL CONTACT MBS PRIOR TO ORDERING 16 V V V y V MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE THAT THEY HAVE THE LATEST REVISION OF THE TRENCH (1 ) ELECTRIC CONSTRUCTION DOCUMENTS. CONDUIT FROM PROPOSED 16 GENERATOR UPDATE 09/20/17 RS 1 UNDERGROUND COAX TRENCH DETAIL 2 ELECTITELEPHONE DUCT BANK BACKUP GENERATOR TO PROPOSED EQUIPMENT ROOM 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 1_ 0 SEE DETAIL 1/AO3 15 HVAC UPDATE 08/11/17 CM 0 0 WWM 6X6 - 18 GAUGE 0 Q 14 HVAC UPDATE 04/14/17 CM 5'-0" 3, " PROPOSED CONCRETE _ FILL WITH CONCRETE 5 PAD (3'-5"X9 -4 ) 13 PLANNER COMMENTS 04/02/15 LM FAINT SAFETY YELLOW _�_ X31 .62 SgFt) RADIUS TOP 8" CONCRETE 3 � SEE DETAIL 5/A03 SLAB 3 12 UNI O HEIGHT 04/01/15 LM CHANGE 4"O.D. PIPE O FILLED WITH CONCRETE = 11 CLIENT COMMENTS 07/18/14 SK 3/4" CHAMFER PROPO ED AT&T DIESEL 3" BA KUP GENERATOR NO. ISSUE OR REVISION DATE BY co 0 PROJECT TITLE: -I I I-I I I I I I-I I I-I I I •' • • • • • . 0 t. CONSTRUCTION DOCUMENTS =1 I 1=1 11= I I—III—I I 1=1 ':. ; '• . �•':�. � • •rs• • ; ,. � . . ;1�. s • • . Finished Grade ` a .X .X x -� .X .X SITE M LI-1025 (—I I f I l I I 1=11=1 11=1 1=1 l I I-- 11— TI _=11� 11= \\ •� -� —� �_) —� ( � —� —� —� ( �- -� —� —� �_� =1 Q SITE ADDRESS: A o o ,0 1040-B HORTONS LANE 001 s GRADE, PAVEMENT, / ..@P 7 V 0 >� SOUTHOLD, NY 11971 � OR FINISHED GRADE a0o� 0� i t° 6" MIN THICK LAYER DISTRICT: 1000 SECTION: 63 / Qa 'o(7 ' � OF 3/4" CRUSHED STONE BLOCK: 1 LOT: 10 �/ ��• o o (COMPACTED) o ZONE: LI- LIGHT INDUSTRIAL REPAIR DISTURBED AREA O TO MATCH EXISTING G I ,e t i . o C N ;,� PROPOSED PROTECTIVE BOLLARDS M&S PROJECT #: 14BECO01 (TYP FOR 12) PAINTED CAUTION 10 COMPACTED SUBGRADE `t YELLOW SEE DETAIL 4/A03 SCALE: AS NOTED DATE: 01/21/10 3000 PSI CONCRETE NOTE: DRAWN BY: GCE CHECKED BY: CCS 1 ) ALL EDGES SHALL BE CHAMFERED. 0D DRAWING TITLE: 2) PROVIDE LIGHT $RUSH FINISH. X-014, DETAILS DRAWING NO.: PAGE NO.: 4 PROTECTIVE BOLLARD 5 CONCRETE PAD DETAIL 6 GENERATOR DETAILED LAYOUT o 2' 4' 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: 1/4"= 1'-0" 22x34 SCALE: 1/2" = 1'-0" A03 6 of 14 1 '-6" ISP WITH 12 RRH UNITS ROPOSED RRH RACK ,r AT&T CABLING WITHIN :r �8pi s" PVC SLEEVES Property of AT&T , NETRATING FLOOR OF ROOM. FIRE STOP Authorized AS PER CODE. .; ELECTRIC, TELCO AND Personnel Only GROUND CONDUITS CConsu/ting Engineers-Construction Inspectors-Land Surveyors PENETRATING FLOOR i Perryville III Corporate Center OF ROOM. 53 Frontage Road, Suite 260 SEAL WATERTIGHT Hampton, NJ 08827 199- 11 " GROUND ROD In case of emergency, or prior to performing Ph 908.537. A 8.537.1398 TYP FOR2) maintenance on this site, call 800-638-2822 www. I N Firr com and reference cell site number LI-1025 G� s PROVIDE NEW 100 AMP g1VJ �j at&t o 1 - 1/2 HR PRIMARY DISCONNECT FIRED RATEDI I SWITCH 3' �ooR (� � I 1I 75 KVA 3 CONTACT INFORMATION SIGN G ,,,, �R 3 —0 X7 —0 X NY PROFESSIONAL ENGINEER#075376 I I TRANSFORMER 11x17 SCALE: NTS 22x34 SCALE: NTS 1 —3/4"—\ I I " IT IS A VIOLATION OF THE LAW FOR ANY PERSON, 16 GAUGE HOLLOW AIR ( ( I 200 AMP 8 UNLESS ACTING UNDER THE DIRECTION OF A LICENSED METAL. B—LABEL HANDLER I 1 1 I SECONDARY DISCONNECT ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. / II 1 2 / 704 1 EXISTING WALL TO I APPLICANT: SIGN DISPLAYING •� / - - - - - - - - - - - - - - - - - - - - -� l BE REMOVED CONTACT / - - - - - - - - - - - - - - - - - - - - INFORMATION AFFIXED 703 I Im II = TO EQUIPMENT ROOM Ln DOOR 04 SEE DETAIL 3/A 04 I I I I DUPLEX RECEPTACLE c1q .. .. DUPLEX On this tower: RECEPTACLE I I I I rA 1y rxc(-r,4 FCC roics # r human " SIGN DISPLAYING CONTACT INFORMATION �£��� � ( EXISTING WALL TO Fw� -,,:varor a,�qr&11 p �i�s ,;,E �,,,& MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE BE REMOVED CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING AFFIXED TO BUILDING EXTERIOR OUTSIDE �• t« �P ,� EW.s�flf3 THAT THEY HAVE THE LATEST REVISION OF THE — — — — — — — OF EQUIPMENT ROOM, SEE DETAIL 3/A04 ¢+ CONSTRUCTION DOCUMENTS. SWITCH 120V/15APROPOSED STUD WALL . SEE DETAIL DETAIL 2/Ao4 16 GENERATOR UPDATE 09/20/17 RS 13LB cot 106" I 4 SAFETY INFORMATION SIGN 00 FIRE EXTINGUISHER I -ry0. 772 1 I 11 x17 SCALE: NTS 22x34 SCALE: NTS 15 HVAC 'UPDATE 08/11/17 CM I n I I 1 14 HVAC UPDATE 04/14/17 CM 1 I POWER I I � " PLANT YV' Existing Ceiling �2) LAYERS OF 5/8 GYPSUM BOARD 13 PLANNER COMMENTS 04/02/15 LM TYPE X) PRIME AND PAINT WHITE _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ I UNIPOLE HEIGHT � � � CCOR OS ON RESISTANT STEEL) 12 CHANGE 04/01/15 LM h ( 1 11 CLIENT COMMENTS 07/18/14 SK III AIR EXTERIOR HANDLER I 1 I 1 FASCADE NO. ISSUE OR REVISION DATE BY I 1 TO REMAIN PAINT & TRIM TO I I I V7UNTOUCHED MATCH ADJACENT PROJECT TITLE: I CONSTRUCTION DOCUMENTS �1 ) LAYER OF 5/8" GYPSUM BOARD SITE #: LI-1025 TYPE X) PRIMED AND 9'-6" PAINTED WHITE FULL HEIGHT (TYP) SITE ADDRESS: (2) PROPOSED CARRIER HVAC 1040-B HORTONS LANE 4 TON UNIT PT R48M21 3 1 2" METAL STUDS 0 16" O.C. SOUTHOLD, NY 11971 STACKED) 20 MSG. CORROSION RESISTANT STEEL Existing Sheet THERMA FIBER INSULATION BETWEEN STUDS DISTRICT: 1000 SECTION: 63 Metal Wall BLOCK: 1 LOT: 10 ZONE: LII- LIGHT INDUSTRIAL FLOOR RUNNER (CORROSION RESISTANT STEEL) M&S PROJECT #: 14BECO01 VINYL BASE 15 SCALE: AS NOTED DATE: 01/21/10 NEW PARTION IN / DRAWN BY: GCE CHECKED BY: CCS LOCATIONS NOTED —/ ON PLANS DRAWING TITLE: EQUIPMENT ROOM DRAWING NO.: PAGE NO.: 1 FLOOR PLAN 0 21 4' 2 WALL SECTION STUD 11x17 SCALE: 1/4"= 19.0 22x34 SCALE: 1/2 - 1 -0 11x17 SCALE: NTS 22x34 SCALE: NTS A04 7 of 14 NOTE: a,, . . ' ' : •! III .� SUPPORT PROPOSED DUCTWORK WITH GALVANIZED g \\� 4"X23"X 1/4" GROUND BAR STEEL STRAPS ATTACHED TO CEILING JOISTS 1 SEE DETAIL 1170/EO2 USING # 10 STEEL SCREWS 0 4'-0" O.C. MAX. ° -:,"„ ` ,; . . g ITHONIA EXIST SIGN/EMERGENCY LIGHT PART# LHOMSW3R 120/277 7777 M THOMAS & BETTS 18" WIDE CABLE RACK Malicid Scherer, # W/ ACCOMPANYING HARDWARE ConsuifingEngineers-ConstructionInspectors-Land Surveyors PART# AL2-5- 18-1-06- 144 Perryville III Corporate Center 53 Frontage Road, Suite 260 PROPOSED 4'X 1 '. 2 BULB LIGHT Hampton NJ 08827.Ph 908.537.1 � , 7.1398 FIXTURE ATTACHED TO HORIZONTAL UNISTRUT SUPPORTS (TYP) www• e. to `T1` � (' rn r. 1 GLEN N'J: RER NY PROFESSIONAL ENGINEER#075376 r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -r —� d' ITISAVIOLATIONOFTHELAWFORANYPERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. (-*j SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. I I I APPLICANT: I II - - - - - - - - - - - - - - - - - - -J I I .. - - - - - - - - - - - - - - - - - - — � .7, CONTRACTOR SHIALL CONTACT M&S PRIOR TO ORDERING O I I I I MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE THAT THEYCOLATEST OF THE NSTRUCTIONDOCUMENTS. o I I I I I 16 GENERATOR UPDATE 09/20/17 RS I- - — — — — — — — — — — — - - — — — — I - - - - - - - - - - - - - - - - - I I I 15 HVAC UPDATE 08/11/17 CM HALO GROUND W/ #2 GREEN I I I INSULATED COPPER WIRE AND I I I 14 HVAC UPDATE 04/14/17 CM 2 CORNER DROPS I I I I I SEE SHEET E03 I 13 PLANNER COMMENTS 04/02/15 LM I I I II I I I I 12 UNIPOLE HEIGHT CHANGE 04/01/15 LM I II _ _ _ _ _ _ _ _ _ GENTEX SMOKE DETECTOR I i 11 CLIENT COMMENTS 07/18/14 SK 7OO-0 —SERTI E S- I _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ I h I I NO. ISSUE OR REVISION DATE BY I I I I I I I PROJECT TITLE: I I I II I I I I I CONSTRUCTION DOCUMENTS I I I SITE #: LI-1025 SITE ADDRESS: 1040-B HORTONS LANE (2) PROPOSED CARRIER HVAC SOUTHOLD, NY 11971 4 TON UNIT PT R48M21 DISTRICT: 1000 SECTION: 63 STACKED) BLOCK: 1 LOT: 10 ZONE: LI- LIGHT INDUSTRIAL M&S PROJECT #: 14BECO01 SCALE: AS NOTED DATE: 01/21/10 15 DRAWN BY: GCE CHECKED BY: CCS DRAWING TITLE: REFLECTIVE CEILING PLAN 1 REFLECTIVE CEILING PLAN 0 2' 4' DRAWING NO.: PAGE NO.: 11x17 SCALE;; 1/4"= 1'-0" 22x34 SCALE: 1/2" = 1'-0" A05 8 of 14 421 [16.6"] " 250 ' + 422 120 89 b [4.7"] [3.5"] R462 [R18.2"] R441 [R17.4"] [16.6"] NONLATCHING DOOR LATCHING DOOR 80 [3.2' (1 PLACE) (2 PLACES) RECOMMENDED ELECTRICAL STUB-UPS 111 (SEE DETAILED VIEW & TOP VIEW) MalickESNIcherer, # AIR FILTER & AIR /FUEL FUEL � , � [4.4 ] RESTRICTION INDICATOR SUPPLY RETURN \ INSIDE 17 Consulting Engineers-Construction Inspectors-Land Surveyors O O O A r194 DESCRIPTION BASE Perryville III Corporate Center __ __ 1 ° o [7.6"] HIGH VOLTAGE STUB-UP AREA 53 Frontage Road, Suite 260 I 94 1) AC LOAD LEAD CONDUIT AREA. Hampton, NJ 08827 [3.7"] LOW VOLTAGE CUSTOMER Ph 908.537.13,,x-F-a)(::9�8:537.1398 CONNECTION BOX 2) 120/240 VAC FROM UTILITY A /. i - I (NOTE 8) 777 (BY OTHERS) WWW I COn1 FUEL VENTS PRIMARY CB CONNECTION 384�� [30.6"] (GLAND PLATE INCLUDED) rl? � c �s�,y� • BOX OPENING B o [15.1"1 TANK a � .� (SEE NOTE 16) STUB-UP LOW VOLTAGE STUB-UP AREA m � ,' FUEL LEVEL SEE STUB-UP PRIMARY HIGH VOLTAGE N STUB-UP AREA WITH ( ) 1 TRANSFER SWITCH ° ° � � AREA ° s�H,` � � AREA DETAIL NOTE 6 ) / p o. '� •' FUEL FILL I VIEW GLAND PLATE COMMUNICATION CONDUITS. 3 lin (NOTE 7) COMMUNICATIONS AND 2-WIRE B START MUST NOT BE RUN IN G L R LOW VOLTAGE o CONDUIT WITH AC WIRING. NY PROFESSIONAL ENGINEER#075376 STUB-UP AREA ° (SEE NOTE16) (NOTE 8) (SEE NOTE 8) IT IS A VIOLATION OF THE LAW FOR ANY PERSON, jj TOP VIEW ° ° o UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. ENGINE BLOCK HEATER (NOTE 2) jj STUB-UP AREA DETAIL VIEW 2X SCALE [j 98„] 43 [1.7"] APPLICANT: TANK STUB-UP AREA (NOTE 6) ' ., , .. . . a .. 10 CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE THAT THEY HAVE THE LATEST REVISION OF THE CONSTRUCTION DOCUMENTS. ENGINE BLOCK' HEATER NOTES: (NOTE 2) 2407 [94'8"] 1. CONTROL PANEL INCLUDES BATTERY CHARGER WITH THREE PRONG CORD. 16 GENERATOR UPDATE 09/20/17 RS 437 X 945 (W X H) 880 X 945 (W X H) 965 OVERALL LENGTH DISCHARGE [38 ] 2. 1500W 120VAC ENGINE BLOCK HEATER WITH THREE PRONG CORD. 1­17.2 X 37.2] [36.6 X 37.2] OVERALL WIDTH AIR INTAKE TYP EACH SIDE (NOTES 9 & 11) 3. 12 VOLT NEGATIVE GROUND SYSTEM. BOLT-ON PANEL BOLT-ON PANEL AND REAR (NOTE 10) 4. GENERATOR MUST BE GROUNDED. 15 HVAC UPDATE 08/11/17 CM 5. CENTER OF GRAVITY & WEIGHT MAY SHIFT SLIGHTLY DUE TO UNIT OPTIONS. 6. STUB-UPS: BASE TANK REQUIRES ALL STUB-UPS TO BE IN THE REAR CONTROL PANEL"-. TANK STUB-UP AREA. 14 HVAC UPDATE 04/14/17 CM (NOTE 1) 7. HIGH VOLTAGE STUB-UP AREA INCLUDES THE AC LOAD LEAD CONNECTION LOW VOLTAGE CUSTOMER TO THE MAIN LINE CIRCUIT BREAKER, THE NEUTRAL CONNECTION, - ® a AND AUXILIARY 120/240V CONNECTION. CONNECTION BOX 8. CONNECTION POINTS FOR CONTROL WIRES. BOTTOM OF LOW VOLTAGE 13 PLANNER COMMENTS 04/02/15 LM • (NOTE 8) CUSTOMER CONNECTION BOX HAS KNOCKOUTS FOR 1/2" AND 1551 MAIN LINE CIRCUIT DISCHARGE 3/4" CONDUIT FITTINGS. [61.1"] BREAKER (MLCB) i ill, DUCT 9. MUST ALLOW FREE FLOW OF DISCHARGE AIR AND EXHAUST. SEE SPEC 12 UNIPOLE HEIGHT 04/01/15 LM (NOTE 15) SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. CHANGE 2310 [91-] HIGH VOLTAGE LEU 10. MUST ALLOW FREE FLOW OF INTAKE AIR. SEE SPEC SHEET FOR MINIMUM OVERALL CONNECTION BOXAIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 11 CLIENT COMMENTS 07/18/14 SK HEIGHT (NOTES 4 & 7) oa/ 11. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM THE RADIATOR IS NOT RECIRCULATED. 1358 12. IT IS THE RESPONSIBILITY OF THE INSTALLATION TECHNICIAN TO ENSURE NO. ISSUE OR REVISION DATE BY [53.5"] ° • ° ° • •, m THAT THE GENERATOR INSTALLATION COMPLIES WITH ALL APPLICABLE • ° ° ° ° - - MLCB ° ° CODES, STANDARDS, AND REGULATIONS. 0 0 0 1354 [53.3"] 13. 190 GALLON USEABLE CAPACITY BASETANK IS INCLUDED WITH GENERATOR. PROJECT TITLE: LOW VOLTAGE 14. UNIT IS SHIPPED WITH FUEL SUPPLY AND RETURN LINES DISCONNECTED ' RE STUB-UP 894 990 E EL AND PLUGGED BETWEEN ENGINE AND FUEL TANK. THIS HAS BEEN DONE FUI EL1168 [46"] ®� 802 736 [29 IGO "] CLEARANCE ' CE O GALLON TO FACILITATE PRESSURE TESTING OF THE TANK IN THE FIELD. CONSTRUCTION DOCUMENTS TYP LL [31.6"] TANK HEIGHT BOTTOM OF CAPAWY 0 FOR INFORMATION REGARDING CONNECTING THE FUEL SUPPLY AND ONLY �A�A��T� CONNECTION BOX RETURN LINES PRIOR TO START UP, SEE THE FUEL TANK FIELD TESTING PROCEDURE (OE5082) SUPPLIED IN THE TANK LOOSE VENTS KIT, WHICH IS SITE #: LI-1025 ' + + + + + + 0 0 o SHIPPED WITH THIS GENERATOR. 15. SEE DRAWING OC3850 FOR DISCHARGE DUCT REMOVAL. REMOVAL OF SITE ADDRESS: X17.45 [0.69"] 914 [36"] COOLANT DUCT WILL PROVIDE ACCESS TO MUFFLER FOR SERVICING. LIFTING BRACKETS -MOUNTING[0 HOLES MOUNTING HOLES 18 [0.7"] l'IRIGHT-SIDEVIEW OVERFLOW 16. ADDITIONAL 2" FEMALE NPT PORTS - PLUGGED OR EQUIPPED WITH 1040-B HORTONS LANE 40 X 60 SLOT TYP 76.2 [3 ] OIL DRAIN 570 TOP-MOUNT SWITCHES DEPENDING ON UNIT OPTIONS. SOUTHOLD NY 11971 [1,58" X 2.36"1 (8 PLACES) 950 [37.4"] (4 PLACES) TANK WIDTH (SHOWN WITH DOORS REMOVED) FUEL (4" NPT) WEIGHT DATA: (INCLUDES EMPTY FUEL TANK) [22.4"] 110 [4.3"] SEPARATOR OIL FILTER GENERATOR: 1409 KG (3106 LBS) DISTRICT: 1000 SECTION: 63 430TYP TYP GENERATOR WITH WOODEN SHIPPING SKID: 1474 KG (3250 LBS) (16.9"] BATTERY 1268 [49.9"] REAR VIEW BLOCK: 1 LOT: 10 TYP CENTER OF GRAVITY (IN BOX) UNITS: mm [INCHES] ZONE: Ll- LIGHT INDUSTRIAL 2692 [106"] TANK LENGTH M&S PROJECT #: 14BECO01 LEFT SIDE VIEW 16 SCALE: AS NOTED DATE: 01/21/10 DRAWN BY: GCE CHECKED BY: CCS DRAWING TITLE: GENERATOR DETAILS 1 GENERATOR DETAILS (SD030) DRAWING NO.: PAGE NO.: 17 SC =: NTS A A 22x SCALE• TS A06 9 of 14 . a nib'.., AR^ $ • Z s`•. or LX WC-R36M21 Std, 42 231 000 —R4M1 Std. Or LX 42 23 18-1/2 13 4 ,000 >= PC , Scherer, TTWCConsu/ting Engineers-Construction Inspectors Land Surveyors - ��� Or L -� 1 20,0 0 Perryville III Corporate Center TTWC-R48M21 Std. or LX 208-230/1 /60 12 18 28.7 45 53 Frontage Road, Suite 260 Hampton, NJ 0.8827 Ph 908.537.134 8.537.1398 www. om ' -R ►0M 1 Std, Or LX TO 00 { S. Scroll �1/ " � /4"' 1 = °m c: '' T ', \ 300 TTW -R4M1 Std, Or L Top 30015. Scroll at Now CIO GL tR NY PROFESSIONAL ENGINEER#075376 TTWC-R36M21 Std, or IT IS A VIOLATION OF THE LAW FOR ANY PERSON, LX . 77 UNLESS ACTING UNDER THE DIRECTION OF A LICENSED LX ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. TTW -*-R M 1 Std. or L 0.75 17.9 96 SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. q. ¢ $: • gY. ; .. , . f ; .. € ,i,. ." r3 9 r''= "Tie, :� { APPLICANT: anr Ce'"a.; 3 s'� �b �'•; ;r 1�. } y>,.g� �w, � .. S a r � , �, 1 s :a• ( ,.'d y,.r #P = •�.,•.< "�.', a. Y r m,„. .. ,. s', , . _ i ? € i t'�° ,"r a < > { h � . ( rs"sH eI •�, 1 µ MEF, s S .x f:e + a -It 1 MECHANICAL PHYSICAL DATA HVAC �, ,y•Tp .a." °` w`�Lis. wx^mfr•. 11x17 SCALE: NTS 22x34 SCALE: NTS w CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE THAT THEY HAVE THE LATEST REVISION OF THE CONSTRUCTION DOCUMENTS. Front Pack H I Left 16 GENERATOR UPDATE 09/20/17 RS 15 HVAC UPDATE 08/11/17 CM 14 HVAC V ; , ,,e� N� • .£t �� � � UPDATE 04/14/17 CM € v _.. 15 13 PLANNER COMMENTS 04/02/ .< . :. LM GF UNIPOLE HEIGHT 04/01/15 LM 12 CHANGE C 11 CLIENT COMMENTS 07/18/14 SK Top N 0 Bottom Right ipp NO. ISSUE OR REVISION DATE BY 9 PROJECT TITLE: n _ CONSTRUCTION DOCUMENTS E @ E ' SITE #: LI-1025 SITE ADDRESS: !> 1 t E 6 _" - 1040-B HORTONS LANE L �. SOUTHOLD NY 11971 DISTRICT: 1000 SECTION: 63 BLOCK: 1 LOT: 10 ZONE: LI- LIGHT INDUSTRIAL ' f` _ M&S PROJECT #: 14BECO01 + 42-00 H 20.50 0 "� f .00 V - SCALE: AS NOTED DATE: 01/21/10 .00 1 21 .50 P - w - > C 36.75 18.50 - 15 DRAWN BY: GCE CHECKED BY: CCS 0 32,75 K 40.50. Y . DRAWING TITLE: > E 21 ,00 L. 2.:25 S - Z - F 3.50 M 1 .25 T - - - MECHANICAL DETAILS G 1 .50 N 10.50 U - 2 IMECHANICAL BASE UNIT DIMENSIONS HVAC DRAWING NO.: PAGE NO.: 1 CALE:: NN 22 34 SCAL NTS A M01 10 of 14 COMMSCOPE E15S09P8001 PCS AMPLIFIER ALCATEL LUCENT 9442 RRH 700L MHz ALCATEL LUCENT NN-20500-305 UA08. 1 REMOTE RADIO HEAD REMOTE RADIO HEAD WEIGHT: 8.8 lbs = UMTS NODE B CABINET DIMENSIONS: H10.2%W6.7"xD2.4" RRH 2x60-850 ` WEIGHT: 51 .0 lbs (WITHOUT MOUNTING BRACKETS) 4. es wi DIMENSIONS: H21 .0"xW12.2"xD10.8" SOLAR SHIELD WITH WEIGHT: 48.5 lbs ° ( ) WEIGHT: VARIES DIMENSIONS: 1­118.5"xW11 .22"08.86" - DIMENSIONS: 1­174.0"xW23.6"023.6" Ma lick B Scherer, P C , RRH 2x60-1900 " Consulting Engineers-Construction Inspectors Land Surveyors Perryville III Corporate Center ' 53 Frontage Road, Suite 260 WEIGHT: 39.625 lbs " °ol Hampton, NJ,08827 -' > DIMENSIONS: H20.08 xW1 1 .22 xD7. 1 Ph 908.537.' x( .537.1398 _ .... www om 71, ? r• °sps°r :x , Vit: � I ... 4 � ` . 'g '� ' �u, :f�,.l COMMSCOPE E15S09P56 roc j= , . f GL ; E .. PCS AMPLIFIER = RER 2 antenna conneclors �. NY PROFESSIONAL ENGINEER#075376 IT IS A VIOLATION OF THE LAW FOR ANY PERSON WEIGHT: 9.3 lbs UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. - DIMENSIONS: H10.8 xW8.3 02.4 SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. APPLICANT: �_., �.r .��« .. .tea .� � •..k�. d .y s`• ..d• an oa ` r CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE THAT THEY HAVE THE LATEST REVISION OF THE CONSTRUCTION DOCUMENTS- . " 16 GENERATOR UPDATE 09/20/17 RS 15 HVAC UPDATE 08/11/17 CM COMMSCOPE SBNHH- 1 D65A ALPHA TECHNOLOGIES NEQ15238 COOPER B-LINE TWO-POST ALCATEL LUCENT RRH4X25-WCS ALCATEL LUCENT RRH2X40-07L-DE TRI-B�kND ANTENNA 24 48V DUAL VOLTAGE POWER SYSTEM EQUIPMENT RACK REMOTE RADIO HEAD REMOTE RADIO HEAD 14 HVAC UPDATE 04/14/17 CM WEIGHT: 33.5 lbs WEIGHT: VARIES 19" PANEL MOUNTING 23" PANEL MOUNTING WEIGHT: 31 .5 lbs WEIGHT: 52.9 Ibs 13 PLANNER COMMENTS 04/02/15 LM DIMENSIONS: DIMENSIONS: (WITHOUT MOUNTING BRACKETS) (WITHOUT MOUNTING BRACKETS) DIMENSIONS: H55.0 xW11 .9 xD7. 1 DIMENSIONS: 1­184.0 xW25.6 xD20.3 'A' = 36"- 108" 'A' = 36"- 108" DIMENSIONS: H31 .5"xW12"xD8.7" DIMENSIONS: H24.8"xW1 1 .5"xD6.1 " UNIPOLE HEIGHT 'B' = 20.31 " 'B' = 24.31 " 12 CHANGE 04/01/15 LM 'C' = 18.31 " 'C' = 22.31 " ,1'' - 'D' _ 17.75" 'D' = 2021 .75" 11 CLIENT COMMENTS 07/18/14 SK 'E' = " 'E' = 16" On 0FA-1 On: NO. ISSUE OR REVISION DATE BY PROJECT TITLE: CONSTRUCTION DOCUMENTS ? -? 4 ? SITE #: LI-1025 SITE ADDRESS: 1040-B HORTONS LANE Ld =.` SOUTHOLD, NY 11971 R1,10 NI.krkinfi-, 'LO $ ,§ _ ' Pj F n71 ,.€ DISTRICT: 1000 SECTION: 63 .. .. BLOCK: 1 LOT: 10 ti i P..o rt ZONE: LI- LIGHT INDUSTRIAL , M&S PROJECT #: 14BECO01 SCALE: AS NOTED DATE: 01/21/10 CHECKED GCE DRAWN BY: � BY: CCS a DRAWING TITLE: EQUIPMENT SPECIFICATIONS DRAWING NO.: PAGE NO.: 1 EQUIPMENT SPECIFICATIONS 11x17 SCALE=: NTS 22x34 SCALE: NTS M02 11 of 14 TO SOURCE 14 w, " PTC CABINET Maiicid ,Scherer, PC , Consulting Engineers-Construction Inspectors-Land Surveyors Perryville III Corporate Center 53 Frontage Road, Suite 260 POWER Hampton, NJ 08827 PANEL Ph 908.537.1300 Fax 908.537.1398 IN EQUIPMENT www.malic - -Com PROPOSED METER ROOM j NN J S ATTACHED TO BUILDING EXTERIOR ��,"C. LOCATION TO BE DETERMINED L BY BUILDING ELECTRICIAN 21 NY PROFESSI EEI�#075376 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROPOSED 200A DISCONNECT ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. W/ (2) 200A FUSES 2" EMT SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. ATTACHED TO BUILDING EXTERIOR i— — 2— 3/0 LOCATION TO BE DETERMINED BY ♦ 1 — 4 GND APPLICANT: BUILDING ELECTRICIAN CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE THAT THEY HAVE THE LATEST REVISION OF THE CONSTRUCTION DOCUMENTS. 16 GENERATOR UPDATE 09/20/17 RS NOTES: 15 HVAC UPDATE 08/11/17 CM 1 . WORK WITH SHEETS A01 Sc A02 FOR ROUTING OF CONDUITS. 2. CONTRACTOR IS TO VERIFY SERVICE CONNECTION METHOD, LOCATION AND MATERIAL WITH UTILITY COMPANY. 14 HVAC UPDATE 04/14/17 CM THIS WILL OCCUR PRIOR TO THE START OF ANY ELECTRICAL WORK. 13 PLANNER COMMENTS 04/02/15 LM 12 UNIPOLE HEIGHT 04/01/15 LM CHANGE ELECTRICAL NOTES: 11 CLIENT COMMENTS 07/18/14 SK CONTRACTOR IS TO VERIFY SERVICE CONNECTION METHOD, LOCATION AND MATERIAL WITH ELECTRIC COMPANY. THIS WILL OCCUR PRIOR TO THE START OF ANY ELECTRICAL WORK. NO. ISSUE OR REVISION DATE BY .ALL ELECTRICAL WORK WILL CONFORM TO THE NATIONAL ELECTRICAL CODE, THE ELECTRICAL CODE FOR THE STATE OF NEW YORK AND ALL NATIONAL AND LOCAL FIRE SAFETY AND BUILDING CODES. PROJECT TITLE: CONTRACTOR IS TO PROVIDE ALL ASSOCIATED MATERIAL ile. STRAPS, CONNECTORS, CRIMPS etc. FOR A CONSTRUCTION DOCUMENTS COMPLETE AND OPERATIONAL ELECTRICAL PROJECT. CONTRACTOR IS TO COORDINATE ALL OF HIS WORK TO MINIMIZE THE DISTURBANCE TO THE EXISTING SITE #: LI-1025 BUILDING OCCUPANTS, WORKERS OR ACCESS REQUIRED BY THE GENERAL PUBLIC OR MAINTENANCE PERSONNEL. SITE ADDRESS: ANY DISRUPTION OF THE EXISTING ELECTRICAL SERVICE MUST BE COORDINATED WITH THE CONSTRUCTION 1040-B HORTONS LANE COORDINATOR AND THE BUILDING CONTACT N. SOUTHOLD, NY 11971 ANY DISRUPTION OF THE EXISTING BUILDING CONDITIONS SHALL BE RETURNED TO THERE PREVIOUS CONDITION OR BETTER. DISTRICT: 1000 SECTION: 63 VERTICAL RUNS OF CONDUIT MUST BE SUPPORTED AT INTERVALS AS REQUIRED BY APPLICABLE CODES. INSTALLBLOCK: 1 LOT: 10 ALL REQUIRED PULL BOXES AND UTILIZE APPROPRIATE WIRE HANGING FITTINGS AND HARDWARE. ZONE: LI- LIGHT INDUSTRIAL CONTRACTOR IS TO PERMANENTLY SUPPLY AND FASTEN NAMEPLATES TO DESIGNATE VOLTAGE, NAME AND EQUIPMENT FED M&S PROJECT #: 14BECO01 FROM. SCALE: AS NOTED DATE: 01/21/10 ALL CUTTING AND PATCHING OF WALLS AND MASONRY REQUIRED FOR THE INSTALLTION OF ELECTRICAL HARDWARE SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR. DRAWN BY: GCE CHECKED BY: CCS PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE FIRE PROOF TO RESTORE ORIGINAL RATING. DRAWING TITLE: ELECTRICAL DETAILS 1 ELECTRICAL SCHEMATIC RISER DIAGRAM DRAWING NO.: PAGE NO.: 11x17 SCALE: NTS 22x34 SCALE: NTS E01 12 of 14 ` : °'+ COAX GROUND BAR COAX GROUND BAR COAX GROUND BAR 0 SECTOR "C" 0 SECTOR "B" 0 SECTOR "A" „ ..`.: .. MaliddScherer, PCw'4% 1 FRICTION ACCESS COVER 10, Consulting Engineers-Construction Inspectors-Land Surveyors Perryville III Corporate Center CN 53 Frontage Road Suite 260 COAX GROUND BAR Ham�t6>` J� GENERATOR AT TOP OF UNIPOLE GPS DEVICE ExIstIng Grade Ph 908.537.4 arc 5� 1398 wwwa wd� � Exlsting Surface er � 4� 8" PVC PIPEto COAX GROUND BAR 0>5376 AT BOTTOM OF UNIPOLE CADWELD CONNECTION CADWELD CONNECTION GLENN J. SCHERER NY PROFESSIONAL ENGINEER#075376 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, PROVIDE A SLOT U GROUND RING UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. IN THE PVC SLEEVE TO ACCOMODATE THE SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. EXTERIOR GROUND RING APPLICANT: GROUND BAR GROUND ROD 5/8 " DIA. 8' L ONG (TYP FOR 2) , y . ._...., . .; 6AWG ° GROUND ROD - Po �'�YP FOR 2 ELECTRIC EQUIPMENT EQUIPMENT PANEL CABINETS RACKS CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING #6AWG MATERIALS OR BIEGINNING CONSTRUCTION TO ENSURE THAT THEY HAVE THE LATEST REVISION OF THE ND & TELCO DOOR CONSTRUCTION DOCUMENTS. CONDUIT DOOR FRAME BOND INTERIOR 16 GENERATOR UPDATE 09/20/17 RS #6AWG GR UND 2 GROUND ROD CABLE INTERIOR ® 11x17 SCALE: NTS 22x34 SCALE: NTS 15 HVAC UPDATE 08/11/17 CM LADDER COAX FEED HVAC TRAY THRU. #6AWG 14 HVAC UPDATE 04/14/17 CM MISC. T1 SURGE GND BAR AT METAL ARRESTOR TELCO BACK DOUBLE CRIMP 13 PLANNER COMMENTS 04/02/15 LM OBJECTS BOARD CONNECTION EACH GROUND CONDUCTOR TERMINATING ON ANY GROUND BAR SHALL HAVE AN IDENTIFICATION TAG ATTACHED AT EACH END UNIPOLE HEIGHT INTERIOR 2 THAT WILL IDENTIFY ITS ORIGIN AND DESTINATION. 12 CHANGE 04/01/15 LM GROUND ?00D (D 3 SECTION "P" — SURGE PROTECTORS #6AWG � CABLE ENTRY PORTS (HATCH PLATES) (2 AWG) 11 CLIENT COMMENTS 07/18/14 SK m 1 �2 5 GENERATOR FRAMEWORK (IF AVAILABLE) (2 AWG) I O 4 TELCO GROUND BAR 2 AWG) NO. ISSUE OR REVISION DATE BY OA COMMERCIAL POWER �OMMON NEUTRAL GROUND BOND A +24V POWER SUPPLY RETURN BAR 2 AWG �2 AWG) „ 3 —48V POWER SUPPLY RETURN BAR 2 AWG PROJECT TITLE: 4 EXOTHERMIC RECTIFIER FRAMES. 13" -0 WELD COAX SUPPRESSION CONSTRUCTION DOCUMENTS NOTE: "A" SITE GROUNDING MUST CONFORM TO SECTION A — SURGE ABSORBERS SITE #: LI-1025 WNS IMPLEMENTATION STANDARDS NEWTON INSTRUMENT COMPANY INC. INTERIOR GROUND RING 2 AWG TECHNICAL SPECIFICATIONS FOR BASE BUTNER, N.C. OR APPROVED EQUAL EXTERNAL EARTH GROUND FIELD BURIED GROUND RING) SITE ADDRESS: STATION GROUNDING AND TVSS 2 AWG METALLIC COLD WATER PIPE IF AVAILABLE) G) 1040-B HORTONS LANE (VERS. 1 .1 6/30/04). N0. REQ. PART N0. DESCRIPTION 2 AWG BUILDING STEEL IF AVAILABLE 2 AWG SOUTHOLD, NY 11971 c ) c 10 1 /4"x4"x30" SOLID GND. BAR „ „ SECTION I — ISOLATED GROUND ZONE DISTRICT: 1000 SECTION: 63 20 2 A-6056 WALL MTG. BRKT. BLOCK: 1 LOT: 10 ALL COMMUNICATIONS EQUIPMENT FRAMES. ZONE: LI- LIGHT INDUSTRIAL 03 2 3061 -4 INSULATORS ISOLATED GROUND BAR — IGB (2 AWG) ® 4 3012- 1 5/8"- 11 x 1 " H.H.C.S. DETAIL NOTES: M&S PROJECT #: 14BECO01 05 4 3015-8 5/8 LOCKWASHER 1 , EXOTHERMICALLY WELD 2 AWG BARE INNED SOLID COPPER SCALE: AS NOTED DATE: 01/21/10 CONDUCTOR TO GROUND BAR. ROUTE C04DUCTOR TO BURIED (RGB) REFERENCE GROUND BAR - DETAIL GROUND RING AND PROVIDE PARALLEL EIJOTHERMIC WELD. DRAWN BY: GCE CHECKED BY: CCS 2. USE PERMANENT MARKER TO DRAW TE LINES BETWEEN DRAWING TITLE: EACH SECTION AND LABEL EACH SECTION ("P", "A", "I") WITH 1 " HIGH LETTERS. ELECTRICAL DETAILS 1 GROUND SCHEMATIC 1170 GROUND BAR DETAIL DRAWING NO.: PAGE NO.: 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS E02 13 of 14 T&B CO. "TY—RAP", 2 AWG GREEN , CAT. #TC376 STANDOFF INSULATED STRANDED COPPER WIRE.BRACKET OR (INTERIOR GROUND EQUIVALENT. 2 -0„ .. a , ON CENTER MAXIMUM RING). x v t l 4 SPACING. 2 AWG GREEN INSULATED STRANDED IN R OUTDOOR ANTENNA CABLES (TYP) 1717 COPPER WIRE. (INTERIOR GROUND CABLE GROUNDING RING). (TYP) (SEE MalickSo'cherer, Pful T&B CO. "C—TAP", CAT. T&B CO. "TY—RAP", CAT. WALL OR ROOF DETAIL 1139) consulting Engineers-ConstructionInspectors-Land surveyors I #54730 CRIMP TYPE TC376 STAND–OFF BRACKET AS REQ'D Perryville III Corporate Center PARALLEL TAP OR OR EQUIVALENT. 2'-0" ON EQUIVALENT. CENTER MAXIMUM SPACING. 53 Frontage Road, Suite 260 Hampton, NJ 08827 Ph 908.537.1300 Fax 08:537.1398 T&B CO. "TY—RAP" RADIUS SHOULD .`��6 AWG (TYP) www.rmalick ererX0 CAT. #TY25M CABLE NOT BE LESS _ �P �L TIE OR EQUIVALENT. THAN 8 IN. —Q±:m "TY—RAP".” ` IP t�+5NN`�I sC »� o T&B CO TY–RAP RF SURGE .• DR LOOPS 2 AWG TINNED ARRESTOR ANDREW (OR SIMILAR) BURNDY TYPE KS23 SOLID BARE CAT. TY25M CABLE TIE SPLIT–BOLT CONNECTOR . (TYP) MULTIPLE ENTRANCE OR EQUIVALENT. COPPER WIRE OR EQUIVALENTWALL/ROOF FEED THRU SOLID TO SOLID MUST ZDIRECTION OF BOND �- ASSEMBLY \ ` ti- GLENN-T'eQ PRLR�✓.. BE SPLIT BOLT. O TURN TO J� BAR GROUND COPPER LUG CLOSURE PLATE NY PROFESSION ALE�INER#075376 SHORTEST DISTANCE QO SEE DETAIL TO GROUND BAR IT IS A VIOLATION OF THE LAW FOR ANY TO HATCHPLATE. Q` 6 AWG GREEN ( 1 1 70 GROUND BAR NEWTON UNLESS ACTING UNDER THE DIRECTION OFA LICENSED INSULATED ) INSTRUMENT CO. ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. STRANDED COPPER INSULATED GROUND SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. WIRE. (UNIT BOND). INSULATED GROUND BAR (COPPER) ,APPLICANT: BAR (COPPER (SEE DETAIL 1170) r (SEE DETAIL 1429 2 AWG SOLID TINNED BCW TO GROUND RING e x - CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING HALO NON DIRECTIONAL CORNER CONNECTION DETAIL 2 HALO GROUND RING WALL SUPPORT .AND C TAP DETAIL EXTERIOR ANTENNA CABLE GROUNDING AT SHELTER COAX ENTRY PORT MATERIALS OR HAVE BEGINNING CONSTRUCTION TO ENSURE 1 3 THAT THEYCONSTRUCTIONTDOCUMENTSION OF THE 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 16 GENERATOR UPDATE 09/20/17 RS INTERIOR 15 HVAC UPDATE 08/11/17 CM GROUND RING (HALO) 14 HVAC UPDATE 04/14/17 CM 13 PLANNER COMMENTS 04/02/15 LM 12 UNIPOLE HEIGHT 04/01/15 LM CHANGE 0000DOUBLE 11 CLIENT COMMENTS 07/18/14 SK 1 2 AWG, GREEN INTERIOR GROUND CRIMP NOTE: COPPER STRANDED RING CONNECTION NO. ISSUE OR REVISION DATE BY „ WIRE (INTERIOR ,., IF THERE IS LIMITED SPACE 3 MAX MIN GROUND RING) PROJECT TITLE: ON THE RIGHT SIDE OF THE �'-- BARE COPPER 44P0000 HATCHPLATE, THE ABOVE SETUP AMAY S T BE IR SECT OASIS LONG SEE DETAIL 'Qi; CONSTRUCTION DOCUMENTS 0000121 � 7� BELOW THE HATCHPLATE. 10" t 1/8" 7 tidig SITE #: LI-1025 ti SITE ADDRESS: COPPER CRIMP1040-B HORTONS LANE INSULATION CONNECTOR T&B �O� SOUTHOLD, NY 11971 HATCHPLATE I #5P4740 OR NOTE: s DISTRICT: 1000 SECTION: 63 APPROVED PRO ED EQUAL BLOCK: 1 LOT: 10 MOUNT CELL REFERENCE GROUND THIS DETAIL IS USED FOR ZONE: LI- LIGHT INDUSTRIAL BAR 6CRgP) BELOW HATCHPLATE „ „ A DOWN CONNECTICN TO AND ALIN P SECTION WITH EDGE P A I AN MGB RGB. OF HATCHPLATE. rpm% / M&S PROJECT #: 14BECO01 EXOTHERMIC WELD AT—Z THE LOWEST POINT ON SCALE: AS NOTED DATE: 01/21/10 THE GROUND BAR. TO BURIED DRAWN BY: GCE CHECKED BY: CCS GROUND RING (BGR) DRAWING TITLE: ELECTRICAL DETAILS 4 CELL REFERENCE GROUND BAR (CRGB) INSTALLATION DETAIL 5 HALO GROUND RING SPLICE DETAIL 6 HALO NON-DIRECTIONAL GROWO RING SPLICE DETAIL DRAWING NO.: PAGE NO.: 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS E03 14 of 14 4.:N" . MTIIE UNDERSIGNED,PURSUANT TO SOUTifOLD TOWN CODE SECTION tz� 280-131(l),ACKNOWLEDGES TIIAT TILE CONDITIONS OF TILE SITE PIAN �-�—AL S FOI1TI I IN THE RESOLUTION OF APPROVAL DATED Consulting Engineers-Construction Inspectors-Land Surveyors ro ARE ACCEPTED(SEE CONDITIONS ON RESOLUTION). Perryville III Corporate Center -T PLEASE PRINT NAIWE Vill A (200C_1 53 Frontage Road Suite 260 z *° 9 A s 'NATURE — "V--_ Hampton, NJ 08827 DATE Ph 908.537.1300 Fax 908.537.1398 APPROVED BY TOWN OFSOL nioLD PLANNENG FO,ARD www.malickandscherer.com Y/ � 'HAIRPERSON SIGNATt:R DATE 01: NE wl��►r Y 0 S ITE : U - 1 025 l NOTE:The approved site development plan shall be valid for a perind of eighteen 08) mon!hs from the date of approval as per code section 2E-9.132A, ............... rz fp 1040- B HORTONS LSOUTHOLD , H 11971 GLENN'JCHERER . � NY P'ROFESSIONA(ENGINFfRs#97,5376 . SCOPE OF WORK: IT IS A VIOLATION OF THE LAIN FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. An Unmanned Telecommunications Facility Including '€l€ -- °- --"- ,; Equipment Cabinets Located inside an Existing Building, SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. — —PROPOSED WORK AREA £ € a 95' Overall Height Unipole with (6) Internally %" , , Installed Antennas in Place of an Existing 40' Tall APPLICANT: '0, Flag Pole and an Emergency Backup Generator. _'w:.„„ ♦ C � / � ♦ ♦ ` `� �-`",;�,�{` '�:��.,,€££ ��,,#F£s I ..'V"�f31�T—��---� a"""pp � a PROJECT DIRECTORY: " / 2 x ♦ ♦ Property Line .../// ♦ �f xf£=,_ ►- �° APPLICANT: •..:;:' -'; / ♦ 17` ' New Cingular Wireless PCS, LLC i / 401 ♦ `' J 400 Hamilton Avenue ♦ ♦ � ' ',€ f'£' � F�,,��r” � �,✓� Suite 6006 y ♦ v� \ ''RR White Plains, NY 10601 O ♦ ♦ ♦ rn \ 11r °_.�.., �',, , 631-424-3028 : .. . . ' ATTORNEY: O % F` CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING Re , Nielsen,SffFFF M r ` Huber & Coughlin, LLP, MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE SITE Y { � r THAT THEY HAVE THE LATEST REVISION OF THE BLOCK f"""-" j • � ,; '''' 36 N. New York Avenue, CONSTRUCTION DOCUMENTS. LOT 10 #. ',_ ;� ``' Huntington, NY 11743 Sou#hol , 1, 631-425-4100 O -'',"., 12 UNIPOLE HEIGHT 04/01/15 L �//, ✓ LY./IjCHANGE M SITE ACQUISITION SPECIALIST: Victoria Brennan 631-807-7836 11 CLIENT COMMENTS 07/18/14 SK 48J �._- RF ENGINEER: ISSUED FOR \ �♦ s,,% s-g:' . 310 07/10/14 CA \ ♦ ,� -: �- ' .: `�''y ` � `" m CONSTRUCTION Ole ♦ / ,C (f T ,, , w" '- .. k PROPERTY OWNER: �, ATTORNEY ♦ y : < , ' '- Q 9 07/01/14 TC --' - � COMMENTS ♦ ♦ / C3�� T `-;, -=Jir I�:1.:lrt ''`, '� YSI XXXII, LLC 01 000,♦ �`y*/ f- ffi' CubeSmart, LP ATTORNEY 5 Old Lancaster Rpad 8 COMMENTS 05/22/14 LM Malvern PA 19355 ---- 7 CLIENT COMMENTS 05/06/14 LL " �� =Greek Dr. ..._„W�..�.. '-,;'.. a ri lit and I08$-208 Mi arasa#tar° araban andlor its su ` Tiers. All ri ht� renre'd. COORDINATES KEY MAP LOCATION MAP LATITUDE: N41003'56.10" (NAD83) NO. ISSUE OR REVISION DATE BY LONGITUDE: W74°25'57.64" (NAD83) NOT TO SCALE NOT TO SCALE GROUND ELEVATION: 39' +/- (NAVD88) PROJECT TITLE: DWG. DWG. TITLE APPLICABLE BUILDING CODES AND STANDARDS LEGAL DESCRIPTION : T01 COVER PAGE DISTRICT: 1000 SECTION #: 63 CONSTRUCTION DOCUMENTS SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS BLOCK: 1 LOT: 10 GN1 GENERAL NOTES ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE ZONE: LI - LIGHT INDUSTRIAL SITE #: LI-1025 RM1 RADIUS MAPNICINITY MAP AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE A01 SITE PLAN DESIGN. SITE ADDRESS: A02 ELEVATION AND DETAILS o BUILDING CODE: o o W 1040-B HORTONS LANE A03 DETAILS [INTERNATIONAL BUILDING CODE (IBC), 2010 AS ADOPTED BY NY STATE BLDG CODE] > > W >O W SOUTHOLD, NY 11971 A04 EQUIPMENT ROOM O O ELECTRICAL CODE: � Z a A05 REFLECTIVE CEILING PLAN [NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70 -2007, NATIONAL ELECTRICAL CODE, AS ADOPTED BY a a a W DISTRICT: 1000 SECTION: 63 NYSTATE] A06 GENERATOR DETAIL Q Q Q S2 BLOCK: 1 LOT: 10 LIGHTNING PROTECTION CODE: ZONE': LI- LIGHT INDUSTRIAL M01 MECHANICAL DETAILS [NFPA 780 -2008, LIGHTNING PROTECTION CODE] ❑ 1:1 ElM02 EQUIPMENT SPECIFICATIONS FIRE/LIFE SAFETY CODE: FIRE CODE OF NEW YORK STATE -2010 CONSTRUCTION MANAGER: DATE M&S PROJECT #: 14BECO01 E01 ELECTRICAL DETAILS E02 ELECTRICAL DETAILS SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS. AMERICAN CONCRETE INSTITUTE (ACI) 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE FSCALE: AS NOTED DATE: 01/21/10 E03 ELECTRICAL DETAILS -u AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH SITE ACQUISITION: DATE EDITION,TIA/EIA 222-F AND ANSUTIA 222-G, STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES: TIA 607, COMMERCIAL BUILDING GROUNDING AND BONDING DRAWN BY: GCE CHECKED BY: CCS REQUIREMENTS FOR TELECOMMUNICATIONSEl F-1INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)81, GUIDE FOR MEASURING EARTH RF ENGINEER: DATE El DRAWING TITLE: RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC EQUIPMENT (TYPICAL DRAFTING STANDARDS FOR ALL SHEETS) IEEE C2 NATIONAL ELECTRIC SAFETY CODE, LATEST VERSION OWNER/OWNER REP: DATE T 0 F COVER PAGE Existing Light, Upper And Lower Case Lettering TELCORDIA GR-1275, GENERAL INSTALLATION REQUIREMENTS When Labeling Existing Features PROPOSED BOLD, UPPER CASE LETTERING WHEN LABELING ANSI T1.311, FOR TELECOM - DC POWER SYSTEMS -TELECOM, ENVIRONMENTAL PROTECTION PROPOSED FEATURES DRAWING NO.: PAGE NO.: FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, Light Lines Represent Existing Features METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, T01 1 of 14 DARK LINES REPRESENT PROPOSED FEATURES #- THE SPECIFIC REQUIREMENT SHALL GOVERN. GENERAL NOTES: ; 1 . THE NOTES CONTAINED HEREIN ARE NOT PROJECT SPECIFIC. THE CONTRACTOR SHALL UTILIZE THE ALL NOTES WHICH PERTAIN TO THE WORK DEPICTED IN THIS PLAN SET. ..: 2. THE CONTRACTOR*S SHALL CONTACT M&S TO VERIFY THAT THEY HAVE BEEN ISSUED ry„ THE LATEST REVISION OF THE CONSTRUCTION DOCUMENTS PRIOR TO THE START OF CONSTRUCTION. mclick 9 S)cherer, , 3. ALL DIMENSIONS AND INFORMATION SHOWN IIV THE DRAWINGS ARE DERIVED FROM Consulting Engineers-Construction/nspectors-Land Surveyors LIMITED FIELD OBSERVATIONS MADE FOR THIS PROJECT. DETAILED INFORMATION WAS Perryville III Corporate Center COLLECTED FOR SPECIFIC WORK AREAS. THIS INFORMATION IS TO BE USED FOR THE 53 Frontage Road, Suite 260 WORK SHOWN ON THESE PLANS ONLY. Hampton, NJ 08827Ph 908.537.1300 Fax 908.537.1398 4. UNLESS SPECIFICALLY REQUESTED BY THE CLIENT OR REQUIRED TO PROCEED WITH www.malickandscherer.com THE CREATION OF THE CONSTRUCTION DOCUMENTS, STRUCTURAL PROBES HAVE NOT of NEw BEEN PREFORMED. BUILDING COMPONENT CONFIGURATION AND CONDITION NOT ti ---;;y�0; OTHERWISE VISIBLE BENEATH SURFACE FINISHES, MAY VARY AND SHALL BE � { CONFIRMED BY THE CONTRACTOR PRIOR TO PROCEEDING WITH CONSTRUCTION. ,�� o 'z . �^r? �� ANY DISCREPANCIES, WHETHER IN CONFIGURATION OR CONDITION SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER. GL'EV J.SCHERER' 5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS & FIELD CONDITIONS PRIOR TO THE NY PROFESSIONAL NG71VL " #075376 START OF CONSTRUCTION. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE IT IS A VIOLATION OF THE LAW FOR ANY PERSON ATTENTION OF THE ENGINEER. THE CONSEQUENCES OF PROCEEDING WITH UNLESS ACTING UNDER THE DIRECTION OF A LICENSED CONSTRUCTION AFTER DISCOVERING A FIELD CONDITION DISCREPANCY AND WITHOUT ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. THE APPROVAL OR RECOMMENDATIONS OF THE ENGINEER, SHALL BE THE SOLE SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. RESPONSIBILITY OF THE CONTRACTOR. APPLICANT: 6. THE CONTRACTOR SHALL ADHERE TO ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES. w ` , 7. CONTRACTOR I RESPONSIBLE FOR ALL NECESSARY PERMITS AND INSPECTIONS TO S COMPLETE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL INSPECTIONS REQUIRED BY THE AUTHORITY HAVING JURISDICTION, INCLUDING, BUT NOT LIMITED TO ELECTRICAL PLUMBING FIRE PROTECTION AND STRUCTURAL. 8. THE CONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY THE ENGINEER OF CONSTRUCTION STAGES WHICH REQUIRE SPECIAL OR CONTROLLED INSPECTIONS WITH A MINIMUM OF 48 HOURS (BUSINESS DAYS) NOTICE. THESE INSPECTIONS INCLUDE, BUT MATERIALS SHALL CONTACT M8S PRIOR TO ORDERING MATALS OR BEGINNING CONSTRUCTION TO ENSURE HAVE THE ARE NOT LIMITED TO, CONCRETE REINFORCEMENT, CONCRETE POURING, STRUCTURAL THAT THEY CONSTRUCTIONTEST DOCUMENTSION OF THE STEEL ERECTION/BOLTING, WELDING AND THE INSTALLATION OF EPDXY ANCHORS. FAILURE TO COORDINATE THESE INSPECTIONS WITH THE ENGINEER MAY PROHIBIT 12 UNIPOLE HEIGHT 04/01/15 LM SIGNOFF WITH THE AUTHORITY HAVING JURISDICTION. CHANGE 9. CONTRACTOR SHALL PROVIDE ENGINEER WITH PHOTOGRAPHS FOR EACH STAGE OF 11 CLIENT COMMENTS 07/18/14 SK CONSTRUCTION. THE PHOTOGRAPHS SHALL INCLUDE, BUT ARE NOT LIMITED TO, BEAM 10 ISSUED FOR POCKETS & PEDESTAL CONNECTIONS. CONSTRUCTION 07/10/14 CA 10. THE CONTRACTOR IS RESPONSIBLE FOR SAFETY DURING CONSTRUCTION. THE ATTORNEY ENGINEER HAS NO RESPONSIBILITY FOR OR CONTROL OVER SAFETY AT ANY TIME. 9 COMMENTS 07/01/14 TC 11 . THE ENGINEER HAS NOT PERFORMED AN INSPECTION FOR ASBESTOS OR OTHERATTORNEY HAZARDOUS MATERIALS. THESE DRAWINGS ARE NOT MEANT TO DEPICT OR IMPLY THE ® 8 05/22/14 LM a PRESENCE OR ABSENCE OF SUCH MATERIALS WITHIN THE PROPOSED WORK AREAS. COMMENTS o c c-- N h� P M 12. TRUE NORTH SHALL BE DETERMINED. CONTRACTOR IS RESPONSIBLE FOR PROPER ' o c 7 CLIENT COMMENTS 05/06/14 LL AZIMUTH ALIGNMENT. Q 13. THE CONTRACTOR SHALL CONTACT THE TELECOMMUNICATIONS CARRIER TO ACQUIRE NO. ISSUE OR REVISION DATE BY THE LATEST RF DATA SHEET PRIOR TO THE START OF CONSTRUCTION. RF INFORMATION ISSUED BY THE TELECOMMUNICATIONS CARRIER SUPERSEDES INFORMATION PROJECT TITLE: CONTAINED HEREIN. 14. ROUTING IS DIAGRAMMATIC AND CONTRACTOR IS TO UTILIZE BEST POSSIBLE ROUTING CONSTRUCTION DOCUMENTS TO EXPEDITE CONSTRUCTION PROCESS. ROUTING SHALL NOT IMPEDE UPON REQUIRED PASSAGEWAYS OR MEANS OF EGRESS. SITE #: LI-1025 APRROVED BY 15. THE CONTRACTOR SHALL PROVIDE NEW PENETRATIONS FOR ROUTING THROUGH FIRE RATED ASSEMBLIES AND FIRE STOP ALL PENETRATIONS AS PER CODE. THE r PLANINING BOARD SITE ADDRESS: CONTRACTOR SHALL BE RESPONSIBLE TO RESTORE THE FIRE RATING OF BUILDING 1040-B HORTONS LANE COMPONENTS IF EXISTING PENETRATIONS ARE USED FOR NEW ROUTING. TOWN OF SOUTHOLD SOUTHOLD, NY 11971 DATE /� 16. ALL DISTURBED AREAS SHALL BE REPAIRED TO MATCH EXISTING ADJACENT, INCLUDING DISTRICT: 1000 SECTION: 63 BUT NOT LIMITED TO FIRE RATED MATERIALS. �.� BLOCK: 1 LOT: 10 17. ANY DISTURBANCE TO ROOFING, FLASHINGS OR ANY EXTERIOR SURFACE SHALL BE ZONE: LI- LIGHT INDUSTRIAL REPAIRED/SEALED WATERTIGHT AND IN ACCORDANCE WITH ANY WARRANTIES, AS M&S PROJECT #: 14BECO01 APPLICABLE. THE GENERAL CONTRACTOR SHALL EMPLOY THE WARRANTY GRANTOR, OR OTHER AUTHORIZED CONTRACTOR, WHERE REQUIRED FOR MAINTENANCE OF THE SCALE: AS NOTED DATE: 01/21/10 WARRANTY. 18. THE PERIMETER AND ANCHORS OF ALL STEEL TO CONCRETE OR MASONRY DRAWN BY: GCE CHECKED BY: CCS CONNECTIONS SHALL BE SEALED WATERTIGHT USING A PURPOSE FORMULATED MASONRY SEALANT. DRAWING TITLE: 19. CONTRACTOR SHALL REMOVE TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. GENERAL NOTES DRAWING NO.: PAGE NO.: GN1 2 of 14 NOTE. =a$ 3 NO FEDERAL AND STATE LANDMARK OR SCENIC BYWAYS ARE LOCATED WITHINk� 14 300' OF THE SUBJECT PARCEL. k / / rt ; 4 / / / 16 17 18 19 20 / C 2 1 / / / B MalickEScherer, N.." I B C D - / / A A Bldg 9 13.1 Consulting Engineers-Construction Inspectors-Land Surveyors dg 8 C ♦ Perryville III Corporate Center � '�' Section: 63.02 ♦ 53 Frontage Road, Suite 260 Ole 1 � Hampton, NJ 08827 � * 37 Ph 908.537.1300 Fax 908.537.1398 37 36 35 34 3 1Rp 1 www.malickandscherer.com 47 46 45 44 4 E D C B A 27 E Founders VillagelVillageCondominiums ` ` � E D C B A NEW Bldg 12 HD 26 A 0Section:i63. 3 :°r ,�" "F A BlOak: 1 Bldg 14 //36 � 31 32 � 1 I F . . cc R 28 29 D E � GLENN J��SCHIEk / C 0 1 NY PROFESSIONAL�NGINEF�R# x676 M g 22 3 24 25 A (� 9.1 IT IS A 1 1 UNLESS ACTOILA ION OR THE LDIRECTION FOR ANY PERSON, OF A LICENSED ' 21 e C D E (� R R• ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. Bldg 13 I - - _�.• '�/ 17a Section: 61 7.1 APPLICANT: " ///iiii�� Block: 1 R 1 • '',-'moi/ ////////// ���//// / / / � rr E /iii S 61ock: 63 //////// // / / // HB //,//////// 25.4 � I O- � _ . . . , .. 3.2 L 9.3 � ` 13.2 /// // / / / / / / / 22 Vacant Land C 0 TRACTOR SHALL CONTACT M&S PRIOR TO ORDERING _1 . a C a n an ` MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE R ////,,/%%///// , / / /►Y / / / / / / / / / / / i• , THAT THEY HAVE THE LATEST REVISION OF THE SITE CONSTRUCTION DOCUMENTS. 1 12 ///////// / / / / / / / / / / / / N Vacant Land R �� ///////// // / / / / / / / / / / // / / / ..� UNIPOLE HEIGHT 1 `,�►iiii//// � � 12 CHANGE 04/01/15 LM LI / / / / / I 5 0+ •t0 �IN� ///////// / / / / / / / / / / / / / / / /�- I C 11 CLIENT COMMENTS 07/18/14 SK 113 1 209' pRpp�� ����//////,// / /•/ / F / / / / / / /� ZONE BOUNDARY LINE (TYP) / / / -4/ / / / / / ` 3.1 �c�, /////// / / / m/ / / / / ki 9 Q 2.1 R ISSUED FOR 1R C 10 CONSTRUCTION 07/10/14 CA 1 30.1 11 'Y% 14 ATTORNEY R / i / / i / / / / �'/ / / / / / / / / 15 R9 COMMENTS 07/01/14 TC 16 %CD 17 R 19 18 8 ATTORNEY 05/22/14 LM R ���.+� 1 1 .1 20 R / COMMENTS ;•-0goo-off 1 R / 1 14h VarieS) 1 7 CLIENT COMMENTS 05/06/14 LL 1 R - ••. (\JV�dt 113 �Qne Horton 8.11 ?a R R 1 R �p /� NO. ISSUE OR REVISION DATE BY 3.1 1 R 7 � 0------- R �. RO?. �' � � �_� PROJECT TITLE: 1 �, 6 �E CONSTRUCTION DOCUMENTS a� 8.2 �R d • �� Section: 63 R e Block: 5 SITE #: LI-1025 Section: 63 ,�n�s�� 12.1 Block: 1 V �O i R SITE ADDRESS: LAND USE LEGEND: ��, 1 .3 5 �♦ Vacant Land ; 1040-B HORTONS LANE R - Re:sidentiol ♦ 0 R, SOUTHOLD, NY 11971 / C - Commercial Industriol ♦ 0 4 , R 0 - Open Space/Residentiol ♦� �- £ APPROVED BY DISTRICT: 1000 SECTION: 63 3.2 ♦` � ' BLOCK: 1 LOT: 10 R ` � � O ,:r PLANNING BOARD ZONE: LI- LIGHT INDUSTRIAL 500' RADIU LINE �� 0 ' , TOWN OF SOUTHOLD ZONING LEGEND: 21 , DATE / M&S PROJECT #: 14BECO01 LI LIGHT INDUSTRIAL - �'' 31 I SCALE: AS NOTED DATE: 01/21/10 R-4�0) RESIDENTIAL LOW DENSITY AA R R — q- Q • 4 7HD�) HAMLET DENSITY RESIDENTIAL �•� � ; DRAWN BY. GCE CHECKED BY: CCS HB� HAMLET BUSINESS �� '0 DRAWING TITLE: C>R-80 RESIDENTIAL LOW DENSITY A O 0� � o R0�) RESIDENTIAL/OFFICE i00 RADIUS MAP/ VICINITY MAP DRAWING NO.: PAGE NO.: 1 RADIUS MAP/VICINITY MAP 11x17 SCALE: 1"= 200'-0" 22x34 SCALE: 1" = 100'-0" RM1 3 of 14 NOTES: 1. SITE PLAN AND PROPERTY LINE DATA SHOWN WAS TAKEN FROM ,.. A SITE PLAN ENTITLED "FINAL TOPO SURVEY" PERFORMED BY D.W. HANNIG L.S., P.C. RE-CERTIFIED ON MAY 1, 2014. THIS DRAWING DOES NOT CONSTITUTE A BOUNDARY SURVEY. `. a 2. THE PROPOSED USE OF THE DEVELOPMENT IS FOR AN De eed UNMANNED WIRELESS COMMUNICATION FACILITY, •43'30 E 626.24 THE FACILITY WILL NOT BE STAFFED FULL TIME. IT WILL BE VISITED NOTE' S17 ne FOR MAINTENANCE APPROXIMATELY ONCE PER MONTH. EXISTING FLAG POLE TO BE REMOVED State P1° TECHNICIAN MAY PARK NEAR COMPOUND ON TECHNICIAN malick 5 ticherer, PC , AND REPLACED WITH NEW 94 GRAY 0006 12 E • � - PARKING AREA. Consu/ling Engineers-Construction Inspectors-Land Surveyors UNIPOLE ON 1 ' HIGH CAISSON ABOVE S3 3. NO SANITARY OR WATER FACILITIES ARE REQUIRED. GROUND LEVEL (95 OVERALL HEIGHT) - " ' 13PC*y„ySpp6�° � ELECTRIC AND TELEPHONE ARE THE ONLY UTILITIES THAT Perryville III Corporate Center ARE REQUIRED. UTILITY SERVICE WILL BE PROVIDED FROM 53 Frontage Road, Suite 260 • / . � - � " ' � UTILITY POLE AS SHOWN. Hampton, NJ 08827Ph 908.537.300 Fax 908.537.1398 4. NO WATER COURSE OR FLOOD PLAINS WILL BE EFFECTED BY www.malickandscherer.com . / • - ' ctlon� 63 � THIS DEVELOPMENT. 5. ACCESS TO THE SITE WILL BE VIA EXISTING HORTONS LANE. °�- NEW y TRAFFIC IMPACTS WILL BE NEGLIGIBLE, SINCE THE SITE IS UNMANNED. ��% ,. C,cN 0 Lot• Use 6. NO TREES/SHRUBS WILL BE AFFECTED BY THIS CONSTRUCTION. ;; � �'• F��9� Building B mere° 2 7. NO SITE LIGHTING IS PROPOSED. ¢mac Com eo� � A�aa�I 150' FALL ZONE Lot Ar pc -a 8. THE CONTRACTOR SHALL ASIDE BY ALL CURRENT LOCAL, },� °�TLx, A 10 STATE, AND NATIONAL CODES THAT ARE APPLICABLE. w 6'g4++- 'Sq. Ft �• �o 9. THE CONTRACTOR SHALL COORDINATE WITH UTILITY GLENN;J SCHERER � 4$� � NY PROFESSIONAL't.,G1NEER�A1l,5376` . •� COMPANIES AND MEET ALL CURRENT UTILITY COMPANY ' �,... , ,�� / O REQUIREMENTS AND SPECIFICATIONS. IT IS AVIOLATION OF THE LAW FOR`rANY PERSON, N ` 10. NO CHANGE IN EXISTING DRAINAGE PATTERNS WILL UNLESS ACTING UNDER THE DIRECTION OF A LICENSED g RESULT FROM THIS PROPOSAL. ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. � � (6) AT&T PANEL Building A -o • ANTENNAS INSTALLED SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. •1 11. NO TRASH DISPOSAL IS REQUIRED IN CONNECTION WITH z WITHIN TOP TWO RF COMPATIBLE THE PROPOSED INSTALLATION. APPLICANT: CYLINDERS OF PROPOSED UNIPOLE 1 �• GPS DEVICE ATTACHED Building c 2 SITE PLAN NOTES m� TO NEW UNIPOLE o SEE DETAIL 3/A03 11x17 SCALE: NTS 22x34 SCALE: NTS M a•g zo v � 4 o BRICK PLANTER AT BASE OF LI District REQUIRED EXISTING PROPOSED = * W '* CS ` FLAG POLE TO BE RESTORED o ., _ -... o CD / AFTER INSTALLATION 74 1 �_ . ..... OF PROPOSED UNIPOLE) Min Lot Size 40,000 S 02,481 SF No Chane ' 9 ' , U� g Building D 7j O CONTRACTOR SHALL CONTACT Mas PRIOR TO ORDERING • • MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE Min Lot Width 100 351 .93 No Change THAT THEY HAVE THE LATEST REVISION OF THE CD (� Building E ! 1 � aCONSTRUCTION DOCUMENTS. O Q_ N ' Q' Offs°° I J ' M 1 n ' • ZOg. S,d,,,k cBk> o. , o Lot Depth 150 403.66 No Change 13 PLANNER COMMENTS 04/02/15 LM o �"'`j ••: OCO AT&T CABLING TRENCHED UNDERGROUND WITHIN s ,,� Min Front Yard 100' 69.0' 296'2, (F) 12 UNIPOLE HEIGHT 04/01/15 (8) 6 PVC SLEEVES FROM EQUIPMENT ROOM TO 25 7.9 (G) CHANGE LM UNIPOLE. SAW CUT ASPHALT PARKING LOT AS REQUIRED. REPAIR PARKING LOT TO MATCH 209.0' (F) 11 CLIENT COMMENTS 07/18/14 SK EXISTING CONDITIONS, SEE DETAIL 1/A03 AND peed Min Side Yard 20' 30.02' 129.0 G Property Line 1 NOTE BELOW - � �61 .23 ( ) ISSUED FOR TECHNICIAN Pune 10 CONSTRUCTION 07/10/14 CA ;� ate Deed Min Both Side > PARKING SPOT PROPOSED AT&T DIESEL BACKUP GENERATOR 1 -45"1"" S '4D W � Yards 40 60.04 627.9 ELECTRIC AND TELCO CONDUITS ATTACHED TO PROPOSED CONCRETE PAD , - " ' N3 N 19"22 245.9' F g ATTORNEY 07/01/14 TC SEE DETAIL 6 AO3 �` - � ) COMMENTS TRENCHED UNDERGROUND FROM 12 P. � .. ` / a) Distance From Unipole to Existing Min Rear Yard 70 50.76 267.4, (G) R T EQUIPMENT ROOM IN I I I I CO SOURCE 0 ATTORNEY BUILDING E. SAW CUT ASPHALT AT&T 300 S.F. EQUIPMENT Structures on PropertyCOMM NTS 08 05/22/14 LM PARKING LOT AS REQUIRED. ROOM IN BUILDING E. UTILIZING Building A: 308.2' Min Landscaped 25% 15% No Change REPAIF, PARKING LOT TO MATCH i N a,k UNITS 703, 704 ,771 AND 772 co Building B: 144.8 NO. ISSUE OR REVISION DATE BY EXISTING CONDITIONS I SEE DETAIL 1/AO4 c6 Max Lot SEE DETAIL 2/AO3 AND NOTE #2 �'°°"O'k € t Building C: 199.1 ' Coverage 30°0 23.28°0 23.29°fo rn �" Office for PROJECT TITLE: Building D: 74.7 Max Building 35' 24' 95' Lawn Mower U-Store-It Height -0 Repair Shop o Building E: 75.2' Max Number a N o W CONSTRUCTION DOCUMENTS N Building F: 180.8' / Qan k N of Stories 2 1 N A o 9-n �� 10 C�jSITE #: LI-1025 o � Q . 1 ask Building G: 181 .3' Q �°C• a PorkW SpacesI� Parking Spaces SITE ADDRESS: SITE 1040-B HORTONS LANE N e Pa S I CE - ti 2 Handicap Spaces Wireless �z - SOUTHOLD, NY 11971 Telecommunications REQUIRED EXISTING PROPOSEDN Existing Meter .o 84 Regular Porkin Spaces and Disconnects 3DISTRICT: 1000 SECTION : 63 •47 Max ht 80N A 951 Techn�c�on Parking Space BLOCK: 1 LOT: 10 _ ZONE: LI- LIGHT INDUSTRIAL - -� Pds Lane NOTE: 87 Total Parking Spaces Tower Setback: NEW CSC CABINET TO BE 5 � o POW Horton Varies) Nearest Dwelling Unit• N/A; N/A 276.7: W;dtn Nearest Res. Pro Line 5D0 N/A 209.0 M&S PROJECT #: 14BECO01 INSIrALLED BY SERVICE E � (Public street - CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES p• PROVIDER G '""° PROPOSED METER AND DISCONNECT AND SEWERS BEFORE THE START OF CONSTRUCTION. Min Lot Area 40,000 SF 302,481 SF No Change SCALE: AS NOTED DATE: 01/21/10 ATTACHED TO BUILDING EXTERIOR. IF ANY DISCREPANCIES FROM THESE PLANS ARISE, TELCO CONDUIT TRENCHED COORDINATE WITH UTILITY COMPANY CONTACT THE ENGINEER (M&S) IMMEDIATELY. ��: APPROVED BY • Min Fence Height 6 N A N A FROM UTILITY POLE TO FOR ELECTRICAL CONNECTION 9 / / DRAWN BY: GCE CHECKED BY: CCS NEW CSC CABINET. COAX CABLE CHART': PLANNING BOARD a.,i. COORDINATE ALLOW FOR 3' ACCESS Max Equipment / WITH SERVICE PROVIDER. CLEARANCE IN FRONT N0. QTY. SECTOR COAX LENGTH � • TOWN OF SOUTHOLD qui ment Area 500 SF N A 300 SF DRAWING TITLE: SEE DETAIL 2/A03 OF NEW METER AND1 8 ALPHA 170Yes NA No ' a DATE Base Screening DISCONNECT (Vegetation) / UtilityPole 2 8 BET 1A 70' `* .� �; SITE PLAN 75KVA Transformer 3 8 GAMMA 170 n C ' � Tower Color Gray N/A Gray GRII , ng. DRAWING NO.: PAGE NO.: 1 SITE PLAN 3 TBULK REQUIREMENTS 11x17 SCALE: 1"= 80'-0" 22x34 SCALE: 1" = 40'-0" 11x17 SCALE: NTS 22x34 SCALE: NTS A01 4 of 14 Fr' REPLACE EXISTING FLAG POLE ` WITH NEW 94 UNIPOLE ON 14.. HIGH CAISSON ABOVE GROUND (3) AT&T PANEL ANTENNAS INSTALLED LEVEL (95' OVERALL HEIGHT) 38" . WITHIN 10 RF COMPATIBLE CYLINDERSNcherer,B 95' +/— AGL DIA (TOP OF U N I POL E) Consu/ting Engineers-Consfrucfion/nspectors-Land Surveyors n Perryville III Corporate Center 53 Frontage Road, Suite 260 92 +/— AGL U (3) AT&T PANEL ANTENNAS INSTALLED Hampton, NJ 08827 (RAD CENTER) WITHIN 10 RF COMPATIBLE CYLINDER Ph 908.537.1300 Fax 908.537.1398 85' +/— AGLwwuv.malickandscherer.com (TOP OF RF COMPATIBLE CYLINDER) 82' +/— AGL f— I ��°�N c�EVv F to ��`' (RAD CENTER) ' (TOP OF RF COMPATIBLE CYLINDER) GLESICHERER�V �`,� NY PROFESSI NAL ENGjNy 6 P 6 R'ANY'IT IS A VIOLATION EMPTY 10' RF COMPATIBLE CYLINDER UNLESS ACTING UNDER OF E.CTIION OF A LICENPERSONSED ENGINEER, ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. 651 LNDERL SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. (TOP OF RF COMPATIBLE CYLINDER)— Y ) APPLICANT: EMPTY 10' RF COMPATIBLE CYLINDER —/ 55' +/— AGLro .. (TOP OF RF COMPATIBLE CYLINDER)_ EMPTY 10' RF COMPATIBLE CYLINDER PROPOSED PROTECTIVE CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING BOLLARDS MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE TYP FOR 12 THAT THEY HAVE THE LATEST REVISION OF THE PAINTED CAUTION CONSTRUCTION DOCUMENTS. YELLOW SEE DETAIL 4/A03 13 PLANNER COMMENTS 04/02/15 LM GPS DEVICE ATTACHED UNIPOLE HEIGHT TO BUILDING EXTERIOR 12 CHANGE 04/01/15 LM SEE DETAIL 3/A03 COAX CABLES ROUTED UP INTERIOR OF PROPOSED --/ 11 CLIENT COMMENTS 07/18/14 SK AT&T 300 S.F. EQUIPMENT UNIPOLE ROOM IN BUILDING E, I UTILIZING UNITS 703, 704 9771 I 10 ISSUED FOR 07/10/14 CA AND 772 I CONSTRUCTION SEE DETAIL 1/A04 BRICK PLANTER AT BASE OF I EXISTING FLAGPOLE (TO BE I 9 ATTORNEY 07/01/14 TC Building E RESTORED AFTER INSTALLATION I COMMENTS OF PROPOSED UNIPOLE) I ATTORNEY 12'+/— AGL I 8 COMMENTS05/22/14 LM (TOP OF GPS) I I 7'-8" +/— AGL I NO. ISSUE OR REVISION DATE BY (TOP OF GENERATOR) oft 1 ' +/— AGL I —(TOP OF BRICK PLANTER/ PROJECT TITLE. — —' CAISSON Ln • 48 CONSTRUCTION DOCUMENTS L — — - - - - - - - - - - - - - - - - - � - - - - - - - i CtJ Lill DIA SITE #: LI-1025 PROPOSED AT&T DIESEL AT&T CABLING TRENCHED UNDERGROUND WITHIN COAX CABLE CHART BACKUP GENERATOR (8) 6" PVC SLEEVES UNDERGROUND FROM � SITE ADDRESS: NO. QTY. SECTOR COAX LENGTH ATTACHED TO PROPOSED EQUIPMENT ROOM TO UNIPOLE. SAW CUT ASPHALT 1040-B HORTONS LANE CONCRETE PAD PARKING LOT AS REQUIRED. REPAIR PARKING LOT SOUTHOLD, NY 11971 1 8 ALPHA 190' SEE DETAIL 6/A03 TO MATCH EXISTING CONDITIONS 2 8 BETA 190' SEE DETAIL 1/A03 `` APPROVED BY DISTRICT: 1000 SECTION: 63 3 8 GAMMA 190' PROPOSED„CONCRETE BLOCK: 1 LOT: 10 PAD (31-5 X9 —4 ) '"'` �LAI��di(�G EOAR� ZONE: LI- LIGHT INDUSTRIAL (31 .62 SgFt) � ,. 7�Ydr, .„ i SEE DETAIL 5/A03 TOWN OF sOu�'tloi.D M&S PROJECT M 14BECO01 DATE 11-15/awl . SCALE: AS NOTED DATE: 01/21/10 V741 1 aft h r' " . TRENCH (3) CONDUITS FROM PROPOSED z ® DRAWN BY: GCE CHECKED BY: CCS BACKUP GENERATOR TO PROPOSED EQUIPMENT ROOM SEE DETAIL 1/A03 DRAWING TITLE: ELEVATION AND DETAILS 1 WEST ELEVATION 0 8' 16' DRAWING NO.: PAGE NO.: 11x17 SCALE:: 1/16"= V-0" 22x34 SCALE: 1/8" = 1'-0" A02 5 of 14 PROVIDE WARNING GRAVEL, PAVE, OR VEGETATE TAPE ORANGE 0.1 MM FLEXIBLE GPS DEVICE TO MATCH EXISTING r /— POLYETHYLENE FILM WHICH , $ SHALL BE RESISTANT TO ACIDS, ' BASES, HYDROCARBONS, AND WATER. A, III COMPACTED BACKFILL « FINISHED GRADE, OR 6TRENCH " OF TOPSOIL TO BE BACK PAVING MATCH SLOPE FILLED ON TOP OF CONDUIT TRENCH 11/4..,, NOM DIA UNDISTURBED AND THICKNESS OF AND GRASS TO BE REPLACED OR SEEDED o SCH 40 PIPE _ EXISTING MclickEticherer, Pk.-,. , UNDISTURBED SOIL N „ 3/8 X 6 X6 Consulting Engineers-Construction Inspectors-Land Surveyors ' •- COMPACTED BACKFILL THROUGH ALUMINUM CONNECTION Perryville III r I o p W/ SATISFACTORY SHEATHING PLATE Corporate Center �- NATIVE OR IMPORTED 3/8"X6„ 53 Frontage Road, Suite 260 ti!i ia�s•�n• f•to.�' s 'a;t;� — t0 d' SOIL Hampton, NJ 08827 N = — ., � . . . . ' ' • , STANDOFF PLATE Ph 908.537.1300 Fax 908.537.1398 UTILITY WARNING TAPE •• '•-• •. CUT TO wrww.malickandscherer.com ':' ;:. ' �:' ''� I I—I �~ ` • aC3'r t� REQUIRED LENGTH snl s . •i f. f Ka M E IN SAND FILL ��a� (2) COAX CABLES 9� �� 16 SAND FILL 3" MIN ELECTRICAL CONDUIT =` w TELEPHONE CONDUIT 3/8"X6"X6" GLENN bHEPER 1..." "V WHERE APPLICABLE * WHERE APPLICABLE * BACKER PLATE NY PROFESSIONANGINE+ER,#07�376'r,�" " MI COORDINATE SIZE TYPE / COORDINATE SIZE AND N) AT&T CABLING WITHIN (8) AND QUANTITY WITH TYPE WITH LOCAL IT IS A VIOLATION OF THE LAV -F6R-ANY-PERSON, HORIZ. & VERT. 6 PVC SLEEVES SCHEDULE 40. LOCAL UTILITY „ UTILITY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED 6 MIN ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. (TYP) NOTES: APPLICANT: 1 . HAND DIG ALL UTILITY CROSSINGS. *SEPARATION DIMENSION TO BE VERIFIED WITH LOCAL UTILITY COMPANY REQUIREMENTS 2. CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES NOTES: �r AND SEWERS BEFORE THE START OF CONSTRUCTION. 1 . HAND DIG ALL UTILITY CROSSINGS. ° , IF ANY DISCREPANCIES FROM THESE PLANS ARISE, °° .. e. CONTACT THE ENGINEER M&S IMMEDIATELY. tl .b 2. CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES .... . 7a7 AND SEWERS BEFORE THE START OF CONSTRUCTION. �m IF ANY DISCREPANCIES FROM THESE PLANS ARISE, 3 GPS DEVICE MOUNT " CONTACT THE ENGINEER (M&S) IMMEDIATELY. 11x17 SCALE: NTS 22x34 SCALE: NTS CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE THAT THEY HAVE THE LATEST REVISION OF THE TRENCH (1 ) ELECTRIC CONSTRUCTION DOCUMENTS. CONDUIT FROM PROPOSED 12 UNIIPOLE HEIGHT 04/01/15 LM 1 UNDERGROUND COAX TRENCH DETAIL 2 ELECT/TELEPHONE DUCT BANK BACKUP GENERATOR TO CHANGE PROPOSED EQUIPMENT ROOM 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS SEE DETAIL 1/AO3 11 CLIENT COMMENTS 07/18/14 SK O O O0 ISSUED FOR 10 07/10/14 CA WWM 6X6 — 18 GAUGE O CONSTRUCTION 5'-0" 3,— „ PROPOSED CONCRETE 5 PAD �3 —5"X9"-4") 9 ATTORNEY 07/01/14 TC PAINT SAFETY YELLOW FILL WITH CONCRETE (31 .62 SgFt) COMMENTS RADIUS TOP 8" CONCRETE SEE DETAIL A 3_�_� L 5/ 03 ATTORNEY SLAB 8 COMMENTS 05/22/14 LM 4"O.D. PIPE 0 7 CLIENT COMMENTS 05/06/14 LL FILLED WITH CONCRETE 3/4" CHAMFER " PROPO ED AT&T DIESEL 3BA KUP GENERATOR NO. ISSUE OR REVISION DATE BY " co _ _ O PROJECT TITLE: M _ o•• • ,e:• • •t '�% • oft •� 1• :s . '.� •. s� :i,, o :•• •s t =� I I=III III—� I =I I E s •. . : t• * F t •�.,i �r =1 I 1=1 11= I 1=1 I 1=1 I 1=1 s•• . s• � • � • • • •• �. �• _� v� CONSTRUCTION DOCUMENTS Finished Grade X X .X .X #100 SITE #: LI-1025 N ��� '� —III—) I I-III—III I I-III—III—III=I I-III—III— I I—III=1 O o SITE ADDRESS: o ° b o c� 11040-B HORTONS LANE oo° 'q o Q SOUTHOLD, NY 11971 GRADE, PAVEMENT, / '� ° OR FINISHED GRADE / o °� M t° 6" MIN THICK LAYER DISTRICT: 1000 SECTION: 63 / M OF 3/4 CRUSHED STONE BLOCK: 1 LOT: 10 i °o REPAIR DISTURBED AREA Q4 (COMPACTED) * t ZONE: LI- LIGHT INDUSTRIAL O 1'0 MATCH EXISTING — — ou p• : N �,,� PROPOSED PROTECTIVE BOLLARDS M&S PROJECT #: 14BECO01 e. I (TYP FOR 12) PAINTED CAUTION 10" COMPACTED SUBGRADE APPROVED BY `t YELLOW SEE DETAIL 4/AO3 SCALE: AS NOTED DATE: 01/21/10 BOARD 3000 PSI CONCRETE NOTE: r, k>r; TOWN OF SOUThIOLD 3,-0„ DRAWN BY. GCE CHECKED BY.. CCS 1 ) ALL EDGES SHALL BE CHAMFERED. � 3'-0" DATE /��$ L �� 3•_p» DRAWING TITLE: 2) PROVIDE LIGHT BRUSH FINISH. ,., , . S't r'iyr e ��• �� DETAILS DRAWIMIG NO.: PAGE NO.: 4 PROTECTIVE BOLLARD 5 CONCRETE PAD DETAIL s GENERATOR DETAILED LAYOUT o 2' 4' 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: 1/4"= 1'-0" 22x34 SCALE: 1/2" = 1'-0" ---I A03 6 of 14 • 1 '-6" 'Aad•''y... Property of AT&T q$ . P PTA v.. DUPLEX RECEPTACLE AT&T CABLING WITHIN Authorized 100 AMP 6" PVC SLEEVES �8) ENETRATING FLOORMalidd e , PRIMARY DISCONNECT F FI STOP Personnel Only �0 ROOM. RE S O s Consu/ting Engineers-Construction Inspectors Land Surveyors SWITCH AS PER CODE. N Perryville III Corporate Center 75 KVA TRANSFO MER ELECTRIC, TELCO AND 53 Frontage Road, Suite 260 GROUND CONDUITS Hampton, NJ 08827 200 AM 19'— 1 1 " PENETRATING FLOOR In case of emergency, or prior to performing Ph 908.537.1300 Fax 908.537.1398 SECONDARY DISCONNEC OF ROOM, maintenance on this site, call 800-638-2822 www.malickandscherer.com SEAL WATERTIGHT and reference cell site number LI-1025 DUPLEX t^.;�=—"E �,� PROVIDE NEW RECEPTACLE at&t h'� r 1 - 1 2 HR / GROUND ROD ? FIRED RATEDNL (TYP FOR 2) 3 DOOR (1) DC 1 VI CONTACT INFORMATION SIGN GLEAN J`SC HERER� `° :: 3 —0 X7 —0 X " POVVERI V NYPROFESSI6I AL,ENGINEER#075376 1 -3/4" 6 _4 BATTERY p�NT ( UMTS 11x17 SCALE: NTS 22x34 SCALE: NTS IT IS A VIOLATION OF THE LAW FOR ANY PERSON, 16 GAUGE HOLLOW RACK 8" UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. METAL. B-LABEL I I I I SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. / 704 1 j EXISTING WALL TO II APPLICANT: � I � SIGN DISPLAYING •� / - - - - - - - - - - - - - - - - - - - - J I BE REMOVED rn 6 I h ,� CONTACT / - - - - - - - - - - - - - - - - - - - -�►{ 1 �•-- 771 I = INFORMATION AFFIXED II FA TO EQUIPMENT ROOM 703 I I `n - a T I I Nlop ' DOOR THERMOSTAT I RACK SEE DETAIL 3/AO4 IF RA�K I o DUPLEX RECEPTACLE I I I N DUPLEX on this tower: I I RECEPTACLE TVSS 1 I I Radio+�° alver�cy � tt1 �t ,y xc rd rCC njl,-n Cir kfmri & 2 (2) PRO OED RRH RACKS WITH I I SIGN DISPLAYING CONTACT INFORMATION �� CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING 18 RRH UNITS EACH AFFIXED TO BUILDING EXTERIOR OUTSIDE4r�`"' �'rrt � ra- granas MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE �.r« xe•4.a� �,f� +«asnra��* �sTHAT THEY HAVE THE LATEST REVISION OF THE OF EQUIPMENT ROOM, SEE DETAIL 3/AO4 Irv,w''�r*'"� f`° '�`�° M CONSTRUCTION DOCUMENTS. SWITCH 120V/1 5A _ _ _ _ _ _ _ _ _ _ _ _ 12 UNIPOLE HEIGHT 04/01/15 LM 13LB CO2 1o'-6" 1 EXISTING WALL TO 00 4 SAFETY INFORMATION SIGN CHANGE FIRE EXTINGUISHER 1 BE REMOVED ao TELCO BOARD 5/8" I I 11x17 SCALE: NTS 22x34 SCALE: NTS 11 CLIENT COMMENTS 07/18/14 SK ELECTRIC SERVICE THICK FRP PLYWOOD I I I PANEL 1 772 I I 10 ISSUED FOR 07/10/14 CA HIGH/LOW TEMP I I I CONSTRUCTION SENSOR 1 II00 II Existing Ceiling �2) LAYERS OF 5/8" GYPSUM BOARD g ATTORNEY 07/01/14 TC HVAC DISCONNECTAi PROPOSED STUD WALL II TYPE X) PRIME AND PAINT WHITE COMMENTS ATTACHED TO WALL SEE DETAIL 2/AO4 II ATTORNEY _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J CEILING RUNNER 8 05/22/14 LM q (CORROSION RESISTANT STEEL) COMMENTS I I 7 CLIENT COMMENTS 05/06/14 LL I II 2'-0" i EXTERIOR FASCADE NO. ISSUE OR REVISION DATE BY 1 0 REMAIN PAINT & TRIM TO I I UNTOUCHED MATCH ADJACENT I I PROJECT TITLE: N r ��FD r CONSTRUCTION DOCUMENTS o � N ,o TYPE XEROF PR MED ANDYPSUM BOARD � �, o. � SITE #: LI-1025 PAINTED WHITE FULL HEIGHT (TYP) SITE ADDRESS: 1040-B HORTONS LANE 9'-6" 3 1/2" METAL STUDS 0 16" O.C. SOUTHOLD, NY 11971 (20 MSG. CORROSION RESISTANT STEEL) Existing Sheet TTHERMA FIBER INSULATION BETWEEN STUDS DISTRICT: 1000 SECTION: 63 (1 ) FLOOR MOUNTED CARRIER HVAC HVAC DUCT WORK Metal Wall BLOCK: 1 LOT: 10 10 TON UNIT PT# 508YNO12 LOUVERS FLOOR RUNNER ZONE: LI- LIGHT INDUSTRIAL (CORROSION RESISTANT STEEL) M&S PROJECT M 14BECO01 / VINYL BASE / SCALE: ,AS NOTED DATE: 01/21/10 / APPROVED BY NEW PARTION IN / LOCATIONS NOTED — / -- PLANNING BOARD DRAWN BY: GCE CHECKED BY: CCS ON PLANS TOWN' OF SOUTHOLD DRAWING TITLE: DATE 4 EQUIPMENT ROOM 1 FLOOR PLAN o 2' 4' 2 WALL SECTION STUD DRAWING NO.: PAGE NO.: 11x17 SCALE: 1/4"= 1'-0" 22x34 SCALE: 1/2" = V-0" 11x17 SCALE: NTS 22x34 SCALE: NTS A04 7 of 14 NOTES: 4"X23"X 1/4" GROUND BAR SEE DETAIL 1 170/E02 1 )"A" = 12"H X 18"W DIFFUSER GRILL. 4 NON w . 2 PROPOSED DUCTWORK TO BE 18 DEEP U.N.O.ITH NIA EXIST SIGN/EMERGENCY =e x LIGHT PART# LH0MSW3R120/277 3)SUPPORT PROPOSED D UCTWORK WITH GALVANIZED STEEL STRAPS ATTACHED TO CEILING JOISTS USING # 10 STEEL SCREWS ® 4'-0" O.C. MAX. THOMAS & BETTS 18" WIDE CABLE RACK Malicksticherer, Pu'"% W/ ACCOMPANYING HARDWARE ConsuitingEngineers-construction Inspectors-Land surveyors PART# All-2-5- 18-1-06- 1144 Perryville III Corporate Center 53 Frontage Road, Suite 260 PROPOSED 4'X1 '. 2 BULB LIGHT Hampton, NJ 08827 FIXTURE ATTACHED TO HORIZONTAL Ph 908.537.1300 Fax 908.537.1398 UNISTRUT SUPPORTS (TYP.) it-6" www.malickandscherer.com 0F NEW Y - - - - - - - - - - - - - - - - - - - - GLENN J.SCHER�R ,, i I I Nle PROFESSIONAL:"ENGI,NEER 0075376 -ZI IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. ♦ I ' O I 1 I SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. ♦ w' I I I ♦ I 11 APPLICANT: 5♦ I _ of I II ♦ L- — — — — — — — — — — — — — — — — — — — - - CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE I— - - - - - - - - - - - - - - - - - - - , I I THAT THEY HAVE THE LATEST REVISION OF THE A I I CONSTRUCTION DOCUMENTS. I I12 CHANGE UNIIPOLE HEIGHT 04/01/15 LM I I I HALO GROUND W/ #2 GREEN I I INSULATED COPPER WIRE AND I I I I 11 CLIENT COMMENTS 07/18/14 SK 2 CORNER DROPS I I I SEE SHEET E03 I I I I i l I I I I ► I ISSUED FOR 10 07/10/14 CA 20GA GALVANIZED SHEET METAL I I I I I I CONSTRUCTION FABRICATED DUCTWORK (TYP.) I I 9 ATTORNEY 07/01/14 TC I 3'-0" 2'-0" I II COMMENTS GENTEX SMOKE DETECTORI � — — —I— — — — 1 — — � � 8 05/22/14 LM ATTORNEY 7000 SERIES (TYP.� I COMMENTS I I I h I I I I it 7 CLIENT COMMENTS 05/06/14 LL I I I II I I I I II I I NO. ISSUE OR REVISION DATE BY I I I I I I I i I I I PROJECT TITLE: - - �' - - - - - - - - - - - - - CONSTRUCTION DOCUMENTS SITE #: LI-1025 C(1 ) FLOOR MOUNTED p SITE ADDRESS: CARRIER HVAC 10 TON _ 1040-B HORTONS LANE p N UNIT PT# 50BYN012 � �� - - SOUTHOLD, NY 11971 Rnjl Q LOUVERSY --~ DISTRICT: 1000 SECTION: 63 BLOCK: 1 LOT: 10 ZONE: LI- LIGHT INDUSTRIAL APPROVED BY M&S PROJECT #: 14BEC001 l4(L'mow' PLANNING BOARD SCALE: AS NOTED DATE: 01/21/10 TOWN OF SOUTh40LD DRAWN BY: GCE CHECKED BY: CCS DATE DRAWING TITLE: REFLECTIVE CEILING PLAN 1 REFLECTIVE CEILING PLAN 0 2' 4' DRAWING NO.: PAGE NO.: 11x17 SCALE: 1/4"= 1 -0 22x34 SCALE: 1/2 = 1w.019 A05 8 of 14 p/�;.'.r}f 400 47 [15,7 -(15.7 ] F^2 Ai „s x , N flin 11 mmm MEM 200[7,9"] MaliddPC'*"' , 236 Consulting Engineers-Construction Inspectors-Land Surveyors Perryville III Corporate Center 53 Frontage Road, Suite 260 rII ' N Hampton, NJ 08827 Ph 908.537.1300 Fax 908.537.1398 244 41 www.malickandscherer.com [9.6�] [1.��] • • 74 LIFTING BRACKETS pF N E�,y 352 �' 40 60 SLOfi "cy�0 [1 [2,9" [1.58 X q '`r 99 540.5 '540,5 540. P'LACEs [3.9 [21,3"] [21.3'] [212"] � .3" ] FRAME MOUNTING T'0' OR PLAN � GONN J:SCHER�1 1 ��; TY " TYP TYP TYP TYP CENTERS NY PROFESSIONktNGIN ; ER# 5 76 IT IS A VIOLATION OF-THE LAW FOR';ANY PERSON, UNLESS ACTING UNDER THE-DIRECTION OF A LICENSED RIGHT SIDE VIEW ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. 2539.7 [111.8"1 SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. DISCHARGE OVERALL LENGTH 1az7.8 [40.5-] APPLICANT: sEE NOTE OVERALL WDTH AIR INTAKE TYP EACH SIDE AIR y � SEE NOTE 14) INTAKE w ,..-CONTROL PANEL LOW VOLTAGE .r. � CUSTOMER CONNECTIDN tCONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING EDS'' NOTE 3) 17,20 MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE [67.7-1 THAT THEY HAVE THE LATEST REVISION OF THE cwn-n "LCB (NOTE 7) « OVERALL CONSTRUCTION DOCUMENTS. HEIGHT UNIPOLE HEIGHT 12 CHANGE 04/01/15 LM 660 11 CLIENT COMMENTS 07/18/14 SK [26"] 10 ISSUED FOR 07/10/14 CA • • CONSTRUCTION MOUNTING PROVISION ATTORNEY 660 [26-] EOR 01/2" ANCHOR 0 906 [35.7"] (COMMENTS 07/01/14 TC NOTE 16 NGAPV FUEL INLET TYP ��� PUCE 4LT 9 T FRAME MOUNTING 760 C3091 CENTERS 8 ATTORNEY 05/22/14 LM LPL. FUEL INLET 1015.7 [40"] COMMENTS 1267 [49.9-3 FRAME WIDTH CENTER SOF GRAVITY 7 CLIENT COMMENTS 05/06/14 LL 2360 [92.9"] REAR VEW FRAME LENGTH NO. ISSUE OR REVISION DATE BY LE" ME VW PROJECT TITLE: NOTES: CONSTRUCTION DOCUMENTS 1 . THE LEFT SIDE OF THE GENERATOR IS SERVICE ACCESSIBLE. 11 . SEE SPEC SHEET FOR DUCT REMOVAL. REMOVAL OF FRONT SITE #: LI-1025 DUCT WILL PROVIDE ACCESS TO MUFFLER. 2. 10 AMP BATTERY CHARGER INCLUDED WITH GENERATOR. _ SITE ADDRESS: 12. 120VAC ENGINE BLOCK HEATER. 3. CONNECTION POINTS FOR CONTROL WIRES. o �� 1040-B HORTONS LANE fV P BOTTOM OF LOW VOLTAGE CUSTOMER CONNECTION BOX HAS 13. MUST ALLOW FREE FLOW OF DISCHARGE AIR AND EXHAUST SEE SPEC ,� Q L= SOUTHOLD NY 11971 KNOCKOUTS FOR 1 /2" & 3/4" CONDUIT FITTINGS. SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. ° "nom DISTRICT: 1000 SECTION: 63 4. GENERATOR MUST BE GROUNDED. 14. MUST ALLOW FREE FLOW OF INTAKE AIR. SEE SPEC SHEET FOR MINIMUM BLOCK: 1 LOT: 10 AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. -- ZONE: LI- LIGHT INDUSTRIAL 5. 12 VOLT NEGATIVE GROUND SYSTEM. 15. IT IS THE RESPONSIBILITY OF THE INSTALLATION TECHNICIAN TO ENSURE M&S PROJECT #: 14BECO01 6. OPTIONAL REMOTE EMERGENCY STOP SHIPPED LOOSE WITH GENERATOR. THAT THE GENERATOR INSTALLATION COMPLIES WITH ALL APPLICABLE CODES, STANDARDS, AND REGULATIONS. APP-ROVED B 7. MAIN LINE CIRCUIT BREAKER MLCB , AC LOAD LEAD CONNECTION AND SCALE: AS NOTED DATE: 01/21/10 , PL/�I��111�G BOARD AUXILIARY 120 240V CONNECTION. 16.ENGINE SERVICE CONNNECTIONS: / FUEL INLET NG/LPV = 1 - 1/4" NPT COUPLING TOWN OF SOUTHOLD DRAWN BY: GCE CHECKED BY: CCS 8. LEVEL 2A SOUND ATTENUATED ENCLOSURE STANDARD WITH GENERATOR. FUEL INLET LPL - 1/4" NPT COUPLING DATE WEIGHT DATA INCLUDES WOODEN SHIPPING SKID � � DRAWING TITLE: 9. DOORS MUST BE ABLE TO OPEN 90 DEG. TO BE REMOVED. STEEL ENCLOSED GENERATOR- 1278 KG 2818 LBS -Q DOORS ARE LOCATED ON THE LEFT SIDE OF THE GENERATOR ONLY. ] ALUMINUM ENCLOSED GENERATOR- 1141 KG [2515 LBS] 10. 'A' IS THE STUB UP AREA FOR THE MLCB AND NEUTRAL CONNECTION. GENERATOR DETAIL 17. TOTAL HEIGHT OF GENERATOR WITH 211 GALLON DIESEL TANK IS 87F . DRAWING NO.: PAGE NO.: 1 GENERATOR GENERAC SD050 11x17 SCALE: NTS 22x34 SCALE: NTS A06 9 of 14 COMMSCOPE E15SO9P8001 ALCATEL LUCENT 9442 RRH 700L MHz ALCATEL LUCENT NN-20500-305 UA08. 1 PCS AMPLIFIER w4 REMOTE RADIO HEAD REMOTE RADIO HEAD WEIGHT: 8.8 lbsi w UMTS NODE B CABINET WEIGHT: 51 .0 lbs (WITHOUT MOUNTING BRACKETS) RRH 2x60-850 DIMENSIONS: H10.2 xW6.7 xD2.4 Holes � DIMENSIONS: H21 .0"xW12.2"xD10.8" (WITH SOLAR SHIELD) WEIGHT: 48.5 lbs WEIGHT: VARIES « "....W . DIMENSIONS: H18.5"xW11 .22"xD8.86" DIMENSIONS: H74.0"xW23.6"xD23.6" MalickgzSciierer, F"! ' Consulting Engineers-Construction Inspectors-Land Surveyors M. . RRH 2x60-1900 � �a• " Po Perryville III Corporate Center 'J ' WEIGHT: 39.625 lbs «' - 53 Frontage Road, Suite 260 ,M., = �`' «�' �a�It yyys� Hampton' NJ 08827 • ?;•j t� DIMENSIONS: H20.08 xW1 1 .22 xD7. 1 ,.a. .._ - -- .. Ph 908.537.1300 Fax 908.537.1398 a' www.malickandscherer.com ► y a 4=„gym. £ ' COMMSCOPE E15SO9P56 sG` NN',J.SCHERER PCS AMPLIFIERa _' 2 � aetllte� NY PROFES IONAUENGOEEIR 07676 SSS ° • '',, X ,, ,,;, WEIGHT: 9.3 lbs ' IT IS A VIQLATION 6' THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE`DIRECTION OF A LICENSED ENGINEER TO ALTER THIS DOCUMENT IN ANY WAY. DIMENSIONS: H 10.8 xW8.3 xD2.4 SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. e It I s APPLICANT: YNy£ " .� `.CRY ,a,�:• ?Ero. �,Y � � `< '^" „'- ':.,.„� :sp - ,. ,S 3 .. •i:ef,•i•,a, vq ro �'.'wo?iw ,x.«.= Y ... u✓^".b` ws rte. ri.,s'*• _;+« l" Power connector Y.: r ;`, �, .$ = f CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING g MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE THAT THEY HAVE THE LATEST REVISION OF THE CONSTRUCTION DOCUMENTS. 12 UNIPOLE HEIGHT 04/01/15 LM CHANGE 11 CLIENT COMMENTS 07/18/14 SK COMMSCOPE SBNHH- 9 D65A ALPHA TECHNOLOGIES NEQ15238 COOPER B-LINE TWO-POST ALCATEL LUCENT - - - ISSUED FOR 10 TRI- BAND ANTENNA 24 48V DUAL VOLTAGE POWER SYSTEM EQUIPMENT RACK RRH4X25 WCS ALCATEL LUCENT RRH2X40 07L DE � REMOTE RADIO HEAD REMOTE RADIO HEAD CONSTRUCTION 07/10/14 CA WEIGHT: 33.5 lbs WEIGHT: VARIES 19" PANEL MOUNTING 23" PANEL MOUNTING WEIGHT: 31 .5 lbs WEIGHT: 52.9 lbs 9 ATTORNEY 07/01/14 TC DIMENSIONS: DIMENSIONS: (WITHOUT MOUNTING BRACKETS) (WITHOUT MOUNTING BRACKETS) COMMENTS DIMENSIONS: H55.0 xW11 .9 xD7. 1 DIMENSIONS: H84.0 xW25.6 xD20.3 'A' = 36$) ft At = 36 -108" DIMENSIONS: H31 .5"xW12"xD8.7" DIMENSIONS: H24.8"xW1 1 .5"xD6.1 " ATTORNEY 'B' = 20.31 'B' = 24.31 8 COMMENTS 05/22/14 LM . 'C' = 18.31 " 'C' = 22.31 " �'• � 'D' = 17.75" 'D' = 21 .75" ft 7 CLIENT COMMENTS 05/06/14 LL 31 On (184 Onty NO. ISSUE OR REVISION DATE BY -" �,n% �,, �w� ", ° � .; � :�=���: � - , . y®p �► � PROJECT TITLE: low"" w r". y f � b«:C, ,' °I y+R.y d d....!`,gs „ ..i a.6 ... s .moi..• .. !i ~ CONSTRUCTION DOCUMENTS _ SITE #: LI-1025 SITE ADDRESS: j j =�� = _. = 1040-B HORTONS LANE r .. , � PM49j SOUTHOLD, NY 11971 ,. ° to DISTRICT: 1000 SECTION: 63 � .. i _ , ,.a«.."°.'Y..e¢ <° Y .6 . ..' � I '$ `" ., ", `R p. i 3. R' •; € Iuul O = N n� BLOCK: 1 LOT: 10 ZONE: LI- LIGHT INDUSTRIAL M&S PROJECT #: 14 E B C001 SCALE: AS NOTED DATE: 01/21/10 ,. DRAWN BY: GCE CHECKED BY: CCS Jr •a"� DRAWING TITLE: EQUIPMENT * f - M _ ;0 ,.D SPECIFICATIONS IG LSs � 1 EQUIPMENT SPECIFICATIONS Y _ , ' DRAWING NO.: PAGE NO.: 11x17 SCALE: NTS 22x34 SCALE: NTS ILVIce_ l' - --- ----- M02 11 of 14 LLL" ' TO SOURCE 4 ., PTC CABINET Malicld �)cherer, , Consu/ting Engineers-Construction/nscectors-Land Surveyors Perryville III Corporate Center 53 Frontage Road, Suite 260 POWER Hampton, NJ 08827 PANEL Ph 908.537.1300 Fax 908.537.1398 IN EQUIPMENT www.malickandscherer.com PROPOSED METER ROOM ATTACHED TO BUILDING EXTERIOR OF NE LOCATION TO BE DETERMINED w Y BY BUILDING ELECTRICIAN 1,31:ANN 4,,SCHER,ER NY PROFS ZONAL ENGINEE #075376 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, PROPOSED 200A DISCONNECT UNLESS ACTING UNDER THE DIRECTION OF A LICENSED W/ (2) 200A FUSESENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. ATTACHED TO BUILDING EXTERIOR—JI2" EMT SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. LOCATION TO BE DETERMINED BY ♦� 1— 4/GNB APPLICANT: BUILDING ELECTRICIAN at , CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE THAT THEY HAVE THE LATEST REVISION OF THE CONSTRUCTION DOCUMENTS. 12 UNIPOLE HEIGHT 04/01/15 LM CHANGE NOTES: 1 . WORK WITH SHEETS A01 & A02 FOR ROUTING OF CONDUITS. 11 CLIENT COMMENTS 07/18/14 SK 2. CONTRACTOR IS TO VERIFY SERVICE CONNECTION METHOD, LOCATION AND MATERIAL WITH UTILITY COMPANY. 10 ISSUED FOR THIS WILL OCCUR PRIOR TO THE START OF ANY ELECTRICAL WORK. CONSTRUCTION 07/10/14 CA 9 ATTORNEY 07/01/14 TC COMMENTS 8 ATTORNEY 05/22/14 LM COMMENTS ELECTRICAL NOTES: 7 CLIENT COMMENTS 05/06/14 LL CONTRACTOR IS TO VERIFY SERVICE CONNECTION METHOD, LOCATION AND MATERIAL WITH ELECTRIC COMPANY. THIS WILL OCCUR PRIOR TO THE START OF ANY ELECTRICAL WORK. NO. ISSUE OR REVISION DATE BY ALL ELECTRICAL WORK WILL CONFORM TO THE NATIONAL ELECTRICAL CODE, THE ELECTRICAL CODE FOR THE STATE OF NEW YORK AND ALL NATIONAL AND LOCAL FIRE SAFETY AND BUILDING CODES. PROJECT TITLE: CONTRACTOR IS TO PROVIDE ALL ASSOCIATED MATERIAL ie. STRAPS, CONNECTORS, CRIMPS etc. FOR A CONSTRUCTION DOCUMENTS COMPLETE AND OPERATIONAL ELECTRICAL PROJECT. CONTRACTOR IS TO COORDINATE ALL OF HIS WORK TO MINIMIZE THE DISTURBANCE TO THE EXISTING SITE #: LI-1025 BUILDING OCCUPANTS, WORKERS OR ACCESS REQUIRED BY THE GENERAL PUBLIC OR MAINTENANCE PERSONNEL. C� SITE ADDRESS: ANY DISRUPTION OF THE EXISTING ELECTRICAL SERVICE MUST BE COORDINATED WITH THE CONSTRUCTION 1040-B HORTONS LANE COORDINATOR AND THE BUILDING CONTACT PERSON. N p SOUTHOLD, NY 11971 - ANY DISRUPTION OF THE EXISTING BUILDING CONDITIONS SHALL BE RETURNED TO THERE PREVIOUS CONDITION OR BETTER. Of , DISTRICT: 1000 SECTION: 63 VERTICAL RUNS OF CONDUIT MUST BE SUPPORTED AT INTERVALS AS REQUIRED BY APPLICABLE CODES. INSTALL BLOCK: 1 LOT: 10 ALL REQUIRED PULL BOXES AND UTILIZE APPROPRIATE WIRE HANGING FITTINGS AND HARDWARE. ZONE: LI- LIGHT INDUSTRIAL CONTRACTOR IS TO PERMANENTLY SUPPLY AND FASTEN NAMEPLATES TO DESIGNATE VOLTAGE, NAME AND EQUIPMENT FED M&S PROJECT #: 14BECO01 FROM. APP-ROVED BY SCALE: AS NOTED DATE: 01/21/10 ALL CUTTING AND PATCHING OF WALLS AND MASONRY REQUIRED FOR THE INSTALLTION OF ELECTRICAL HARDWARE SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR. PLANNING 130AR-D TOWN OF SOUTHOLD DRAWN BY: GCE CHECKED BY: CCS PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE FIRE PROOF TO RESTORE ORIGINAL RATING. DATE � �- odd f' DRAWING TITLE: ELECTRICAL DETAILS 1 ELECTRICAL SCHEMATIC RISER DIAGRAM DRAWING NO.: PAGE NO.: 11x17 SCALE: NTS 22x34 SCALE: NTS E01 12 of 14 N y w,.„;;;,;say✓• COAX GROUND BAR COAX GROUND BAR COAX GROUND BAR 0 SECTOR "C” 10 SECTOR "B" 0 SECTOR "A" f 01 Malick B Scherer, FRICTION ACCESS COVER 1 consulting Engineers-Construction Inspectors-Land Surveyors Perryville III Corporate Center CN 53 Frontage Road, Suite 260 GENERATOR COAX GROUND BAR GPS DEVICE Ph 9Q8.537 Hampton, NJ(08827 AT TOP OF UNIPOLE Exlstln Grade 300 Fax 908.537.1398 Exlsting Surface www.malickandscherer.com 811 PVC PIPE c y� COAX GROUND BAR to AT BOTTOM OF UNIPOLE ` ` �L CADWELD CONNECTION CADWELD CONNECTION �` �`U GLENNJ,.:SCHERER NY PROFESSIONAL'S' GIN7E��k#6753 6 r .a_` ''. IT IS A VIOLATION OF THE LAW FOR ANY PERSON, PROVIDE A SLOT GROUND RING UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. IN THE PVC SLEEVE SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. TO ACCOMODATE THE EXTERIOR GROUND RING APPLICANT: GROUND BAR GROUND ROD 5/8 " DIA. 8' LONG (TYP FOR 2) APPROVED BY 6 AW G PLANNING BOARD R TOWN OF SOUTHOLD GROUND OD p (TYP FOR 2) ELECTRIC EQUIPMENT EQUIPMENT DATEdµ; . PANEL CABINETS RACKS A - ' lR�,_ C CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING #6AWG G MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE ND & TELCO � ) THAT THEY HAVE THE LATEST REVISION OF THE CONDUIT DOOR DOOR CONSTRUCTION DOCUMENTS. BOND FRAME INTERIOR 12 UNIPOLE HEIGHT 04/01/15 LM #6AWG GROUND 2 GROUND ROD CHANGE CABLE INTERIOR • BAR 11x17 SCALE: NTS 22x34 SCALE: NTS 11 CLIENT COMMENTS 07/18/14 SK LADDER COAX FEED HVAC TRAY THRU. 10 ISSUED FOR 07/10/14 CA #6AWG CONSTRUCTION MISC. T1 SURGE GND BAR AT ATTORNEY METAL ARRESTOR TELCO BACK DOUBLE CRIMP 9 COMMENTS 07/01/14 TC OBJECTS BOARD CONNECTION EACH GROUND CONDUCTOR TERMINATING ON ANY GROUND BAR SHALL HAVE AN IDENTIFICATION TAG ATTACHED AT EACH END 8 ATTORNEY 05/22/14 LM INTERIOR 2 THAT WILL IDENTIFY ITS ORIGIN AND DESTINATION. COMMENTS GROUND 0 3 SECTION "P" — SURGE PROTECTORS #6AWG � et CABLE ENTRY PORTS (HATCH PLATES) (2 AWG) 7 CLIENT COMMENTS 05/06/14 LL m t "2 5 GENERATOR FRAMEWORK (IF AVAILABLE) (2 AWG) I 0 0 4 TELCO GROUND BAR (2 AWG) NO. ISSUE OR REVISION DATE BY oCOMMERCIAL POWER COMMON NEUTRAL GROUND BOND 2 AWG A " +24V POWER SUPPLY RETURN BAR 2 AWG ( , 3 —48V POWER SUPPLY RETURN BAR 2 AWG PROJECT TITLE: ' 4" EXOTHERMIC RECTIFIER FRAMES. WELD COAX SUPPRESSION CONSTRUCTION DOCUMENTS NOTE: " " SITE GROUNDING MUST CONFORM TO SECTION A — SURGE ABSORBERS SITE #: LI-1025 WNS IMPLEMENTATION STANDARDS NEWTON INSTRUMENT COMPANY INC. INTERIOR GROUND RING TECHNICAL SPECIFICATIONS FOR BASE BUTNER, N.C. OR APPROVED EQUAL EXTERNAL EARTH GROUND FIELD BURIED GROUND RING �] SITE ADDRESS: STATION GROUNDING AND TVSS ( 1040-B HORTONS LANE VERS. 1 .1 6/30/04,. DESCRIPTION 2 AWG METALLIC COLD WATER PIPE (IF AVAILABLE Nm SOUTHOLD, NY 11971 C J N0. REQ. PART N0. 2 AWG BUILDING STEEL (IF AVAILABLE) 2 AWG) 1 lc 1 4"x4"x30" SOLID GND. BAR ( R O / " " DISTRICT: 1000 SECTION: 63 SECTION I — ISOLATED GROUND ZONE c� t�� 02 2 A-6056 WALL MTG. BRKT. BLOCK: 1 LOT: 10 ALL COMMUNICATIONS EQUIPMENT FRAMES. ZONE: LI- LIGHT INDUSTRIAL U3 2 3061 -4 INSULATORS ISOLATED GROUND BAR — IGB (2 AWG) -� 4 4 3012- 1 5/8"- 1 1 x 1 " H.H.C.S. DETAIL NOTES: M&S PROJECT #: 14BECO01 Q 4 3015-8 5/8 LOCKWASHER 1 . EXOTHERMICALLY WELD 2 AWG BARE TINNED SOPP LID COPPER SCALE: AS NOTED DATE: 01/21/10 CONDUCTOR TO GROUND BAR. ROUTE CONDUCTOR TO BURIED (RGB) REFERENCE GROUND BAR — DETAIL. GROUND RING AND PROVIDE PARALLEL EXOTHERMIC WELD. DRAWN BY: GCE CHECKED BY: CCS 2. USE PERMANENT MARKER TO DRAW THE LINES BETWEEN DRAWING TITLE: EACH SECTION AND LABEL EACH SECTION ("P", "A", "I") WITH 1 " HIGH LETTERS. ELECTRICAL DETAILS DRAWING NO.: PAGE NO.: 1 GROUND SCHEMATIC 1170 GROUND BAR DETAIL 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS T22x34 SCALE: NTS E02 13 of 14 T&B CO. "TY—RAP", 2 AWG GREEN CAT, ##TC376 STANDOFF INSULATED STRANDED BRACKET OR COPPER WIRE " 2NG). NTERIOR GROUND r EQUIVALENT. 2 —0 ON :. . ;.�CENTER MAXIMUM . ' , k°.� SPACING. h . $' K 2 AWG GREEN INSULATED STRANDED IN R O�TDOOR ANTENNA CABLES (TYP)COPP RING). KIT ER WIRE. INTERIOR GROUND CABLE GROUNDING (TYP) Mclickbticherer, P", C , WALL OR ROOF SEE T&B CO. "C—TAP", CAT, T&B CO. "TY—RAP", CAT, DETAIL 1139) Consulting Engineers-Construction Inspectors-Land Surveyors ##54730 CRIMP TYPE TC376 STAND—OFF BRACKET AS REQ'D Perryville III Corporate Center PARALLEL TAP OR OR EQUIVALENT. 2'-0" ON 53 Frontage Road, Suite 260 EQUIVALENT, CENTER MAXIMUM SPACING. Hampton, NJ 08827 Ph 908.537.1300 Fax 908.537.1398 T&B CO. "TY—RAP" RADIUS SHOULD .`�6 AWG (TYP) www.malickandscherer.com CAT, ##TY25M CABLE NOT BE LESS _ TIE OR EQUIVALENT, THAN 8 IN. "TY—RAP" RF SURGE DRIP LOOPS of NEW 2 AWG TINNED o T&B CO. , ARRESTOR �' ANDREW (OR SIMILAR) �`�' ��c yo BURNDY TYPE KS23 CAT, TY25M CABLE TIE F - SPLIT—BOLT CONNECTOR OR EQUIVALENT, (TYP) MULTIPLE ENTRANCE SOLI A COPPER WIRE WALL/ROOF FEED THRUM OR EQUIVALENT, SOLID TO SOLID MUST DIRECTION OF BOND ASSEMBLY G'LE N J. CHEREk BE SPLIT BOLT, TO TURN TO GROUND BAR LUG CLOSURE PLATE NY PROFESSIONAL EN61N'960753 6 BAR COPPER TO GROUND BAR SHORTEST DISTANCE Q� SEE DETAIL IT IS A VIOLATION OF THE LAW FOR ANYPERSON TO HATCHPLATE. UNLESS ACTING UNDER THE DIRECTION OF A LICENSED � 6 AWG GREEN 1170) GROUND BAR NEWTON INSULATED INSTRUMENT CO ENGINEER,TO ALTER THIS DOCUMENT IN ANY WAY. STRANDED COPPER INSULATED GROUND SIGNATURE AND SEAL NOT VALID UNLESS ORIGINAL. WIRE. (UNIT BOND). INSULATED GROUND BAR (COPPER) APPLICANT: BAR (COPPER) (SEE DETAIL 1170) � (SEE DETAIL 1429 2 AWG SOLID TINNED BCW TO GROUND RING ' JE CONTRACTOR SHALL CONTACT M&S PRIOR TO ORDERING HALO NON DIRECTIONAL CORNER CONNECTION DETAIL 2 HALO GROUND RING WALL SUPPORT AND C TAP DETAILEXTERIOR ANTENNA CABLE GROUNDING AT SHELTER COAX ENTRY PORT MATERIALS OR BEGINNING CONSTRUCTION TO ENSURE 1 NON-DIRECTIONAL 3 THAT THEY HAVE THE LATEST REVISION OF THE CONSTRUCTION DOCUMENTS. 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS UNIPOLE HEIGHT 12 04/01/15 LM CHANGE INTERIOR 11 CLIENT COMMENTS 07/18/14 SK GROUND RING (HALO) ISSUED FOR 10 CONSTRUCTION 07/10/14 CA .1LI 9 ATTORNEY 07/01/14 TC � COMMENTS 8 ATTORNEY COMMENTS 05/22/14 LM 10000 1 J 1 INTERIORDOUBLE 7 CLIENT COMMENTS 05/06/14 LL 2 AWG, GREEN GROUND CRIMP NOTE: COPPER STRANDED RING CONNECTION NO. ISSUE OR REVISION DATE BY " MIN WIRE (INTERIOR c. . . 0000 IF THERE IS LIMITED SPACE 3 MAX GROUND RING) PROJECT TITLE: ON THE RIGHT SIDE OF THE BARE COPPER HATCHPLATE, THE ABOVE SETUP 0000 MAY BE MIRRORED AS LONG SEE DETAIL 'Qi. CONSTRUCTION DOCUMENTS AS THE P SECTION IS 1217 P-" BELOW THE HATCHPLATE. 10" ± 11/8" aC"i SITE #: LI-1025 0 �Fil, � SITE ADDRESS: 00001COPPER CRIMP n� `� 1040-B HORTONS LANE INSULATION CONNECTOR T&B '4Q2 0� SOUTHOLD, NY 11971 : HATCHPLATE i X54740 OR NOTEDISTRICT: 1000 SECTION: 63 APPROVED EQUAL BLOCK: 1 LOT: 10 MOUNT(( CELL REFERENCE GROUND THIS DETAIL IS USED FOR ZONE: LI- LIGHT INDUSTRIAL AND AR IG�IR�P'� SECTOION WIH HATCHPLATE GE "P" "A" "I" A DOWN CONNECTION TO OF HATCHPLATE. AN MGB/RGB. M&S PROJECT #: 14BECO01 EXOTHERMIC WELD AT THE LOWEST POINT ON--ZAPPROVED BY SCALE: AS NOTED DATE: 01/21/10 THE GROUND BAR. ■ PLANNING aoARD TO BURIED DRAWN BY: GCE CHECKED BY: CCS GROUND RING TOWN OF SOUTHOLD (BGR) DALE DRAWING TITLE: ELECTRICAL DETAILS 4 CELL REFERENCE GROUND BAR (CRGB) INSTALLATION DETAIL 5 HALO GROUND RING SPLICE DETAIL 6 HALO NON-DIRECTIONAL GROUND RING SPLICE DETAIL DRAWING NO.: PAGE NO.: 11x17 SCAILE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS E03 14 of 14