Loading...
HomeMy WebLinkAbout49244-Z FF TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 49244 Date: 5/15/2023 Permission is hereby granted to: Silver Sands Hld s I LLC c/o Alexander Perros 19215 Soundview Ave Southold NY 11971 To: (unit 28) legalize "as built" alterations and deck addition to existing motel building as applied for per DEC NJ letter, At premises located at: 1220 Silvermere Rd, Greenport SCTM #473889 Sec/Block/Lot#47.-2-13 Pursuant to application dated 12/9/2022 and approved by the Building Inspector. To expire on 11/13/2024. Fees: AS BUILT-COMMERCIAL ADDITIONS/ALTERATIONS $692.80 CERTIFICATE OF OCCUPANCY $50.00 Total: $742.80 Building Inspector rt ;. TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone 631 765-1802 Fax 631 765-9502 htt s // rww.sotitlioldtownn �o�v' P ) ) 1 , Date Received APPLICATION FOR BUILDING PERMIT I t � �GI� III►�/ I For Office Use Only 9 ,2022 PERMIT NO. Building Inspector°, LM SUILO NG DEPT Applications and forms must be filled out in their entirety. Incomplete TOWNCIFSOUTH6LID applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date:December 1, 2022 OWNER(S)OF PROPERTY: Name:SILVER SANDS HOLDINGS I, LLC SCTM#1000-47-2-13 Project Address: 1220 Silvermere Road, Unit 28 ,Greenport, NY 11944 Phone#:917-318-0027 Email:ALEX@SILVERSANDS-MOTEL.COM Mailing Address: 1400 SILVERMERE ROAD, GREENPORT, NY 11944 CONTACT PERSON: Name:RICHARD VANDENBURGH, ESQ.. Mailing Address:42155 MAIN ROAD, PECONIC, NY 11958 Phone#:631-613-9019 Email:RICH@GREENPORTBREW.COM DESIGN PROFESSIONAL INFORMATION: Name:JOHN CONDON, PE. - CONDON ENGINEERING Mailing Address:1755 SIGSBEE ROAD, MATTITUCK, NY 11952 Phone#:631-298-1896 Email:condoneng@optonline.net CONTRACTOR INFORMATION: Name:HIGHLAND PEAK GROUP, LLC Mailing Address:19215 SOU NDVIEW AVENUE, SOUTHOLD, NY 11971 Phone#.917-318-0027 Email:ALEX@SILVERSANDS-MOTEL.COM DESCRIPTION OF PROPOSED CONSTRUCTION []NewStructure ❑Addition E Alteration RRepair ❑Demolition Estimated Cost of Prct: See Attached. $ I ❑Other � - --- Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes 51 No 1 m PROPERTY INFORMATION Existing use of property:R_3 Intended use of property: R-3 Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-3 this property? ❑Yes ®No IF YES, PROVIDE A COPY. Q Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): ®Authorized Agent ❑Owner Signature of Applicant: Date: 'Z 17 L STATE OF NEW YORK) SS: COUNTY OF SUFFOLK RICHARD W. VANDENBURGH being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)heisthe AGENT (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 20 DECEMBER 22 Notary Public CONNIE D.BUNCH Notary Public,State of New York No.01 BU6185050 PROPERTYAUTHORIZATION Qualified in Suffolk County ('''here the applicant is not theowner) Commission Expires April 14,2 Oa I, ALEX PERROS residing at,19215 SOUNDVIEW AVENUE, , SOUTHOLD, NY RICHARD W. VANDENBURGH do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein, Owner's Signature Date ALEX PERROS Print Owner's Name 2 9 N. J. MAZZAFERRO P.E. PO Box 57, Greenport,N.Y. 11944 Phone- 516-457-5596 Consulting Engineer March 16, 2023 Design,,,Construction. Inspection Silver Sands Holdings 1, LLC 1400 Silvermere Road, Greenport,NY 11944 Re: - Certification Statement-Construction Costs for Refurbishment of Cabins 26-27-29 House Unit 28 Tax Lot— 1000-047-02-13 (1220 Silvermere Road, Gpt,NY 11944; Cabins 26-27,29 House 28) Property Occupancy Code—Comm—Motel/Cabins—NYS Building Code Section 310.2 Project Category—Alteration 2 -NYS Existing Building Code Section 603 Tax Info—Comm—Motel—3 Buildings on 0.50 acres—Pre-Existing 1957. CofO's Exist for Building 29, 11/27/57—Addition, 11/21/84—Green House.No other CofO's. On numerous occasions from 11/2022 thru 2/2023 I inspected the Silver Sands Site at the noted address. During the inspection I met with the Project Manager(Alex Perros) and he provided me with the project documentation for the proposed refurbishment. The documents included: - Project Design Drawings (1 set) -Real Estate Evaluation/Certification Statement -Newmark Valuation&Advisory -Tax Records from Southold Town Files The Project Manager requested Professional Engineering Services. The scope of the services included developing a construction estimate for the Project and comparing the estimate to the data provided in the Appraisal Report prepared by Newmark Valuation and Advisory. The scope also included defining the work category per the current NYS Existing Building Code and evaluating the energy use improvements per the current NYS Energy Conservation Code. Based upon my on-site inspection,my review of the project plans and professional experience I developed a Construction Cost Estimate for the Project. The estimate was developed using my professional experience,knowledge of the site and local contracting conditions,up to date pricing from suppliers and the MEANS System for Cost Estimating. Specific site information and details provided in the drawings were 1 considered in the estimating process. The estimate was developed using a format that allowed direct comparison with the Appraisal Report. My estimate is based upon the actual design plan elements, square footage costs for the construction, geographic factors for the project location and actual conditions observed and confirmed at the site. The estimate includes 2022 cost adjustments and labor availability factors. Result—Based upon inspection of this project and to the best of my knowledge, belief and professional judgment, the construction cost for the planned refurbishment of these (3) individual structures is: Total Cost—Cabins 26-27-29, House 28 = $297,112 (A copy of my summary estimate is attached). Base Line Cost for Completely New Structures= $1,055,222 (Newmark Valuation) Therefore the planned refurbishment for the Cabins and House on this Tax Lot is 28% of the replacement cost for the entire the building. YS and Southold Town Code Definitions & Classification of Work: The 2020 Building Code of the State of New York contains the following definition: SUBSTANTIAL IMPROVEMENT - Any repair reconstruction, rehabilitation, alteration, addition or other improvement of a building or structure, the cost of which equals or exceeds 50 percent of the market value of the structure before the improvement or repair is started. The Town of Southold Code—Chapter 280—Zoning Article 280-4 - contains the following: DEMOLITION-Any removal of a structure or portion thereof, where the total cost of the reconstruction of the structure or portion thereof exceeds 50% of the market value of the existing structure before the start of removal. The Cabins are single story structures with a limited floor plan with uncomplicated interior walls and simple room design (i.e., single room and small bathroom). As a result, the use of materials and sophisticated components and finishes is limited. The House is a one and a half story structure with a storage loft. The floor plan includes three bedrooms, loving room, kitchen/dining room and two bathrooms. The structure has uncomplicated interior walls and simple room design. As a result, the use of materials and sophisticated components and finishes is limited. 2 For example, all of the existing foundation, exterior wall framing, sheathing and structural components remain in place. The only planed work for these elements is to repair any deterioration discovered during the construction. The installation of supplemental headers, and removal and fill in of window openings falls well below the 50% demolition definition. Even in the event of discovery of additional repairs due to deterioration of the existing structural components, the reasonable additional work value would add no more than an additional 10%to the total cost and remain well below the 50%threshold. The plumbing, electrical and HVAC installation and fixtures are standard class and simplistic with uniform installations. In addition, the finishes, floor coverings and tiling are also basic commercial grade and standard quality. The specific and actual numbers balanced against the reconstruction cost result in the following conclusion: The actual expenses incurred and contractual agreements to complete the reconstruction of the structures on this tax lot reveals that the total cost will be 28% of the total value of the structures. This is below the 50% demolition limit and rebuilding costs as defined by the NYS-Building Code and the Southold Town Code. Additionally, per the NYS Code, the work to be included with substantial improvement should not include: Any project for improvement of a building required correcting existing health, sanitary or safety code violations identified by the building official and that are the minimum necessary to assure safe living conditions. Based on this definition in the NYS Code and my inspections of the existing structure, adjustments should be made to the estimated cost of the rehabilitation/alteration work for comparison purposes. My Professional Engineering opinion is that the following work items would have to be done to assure safe living conditions as defined by the code. Although there were no actual violations issued for these conditions, my professional judgement is that the following items have to be addressed in order to safely re-open this facility: 1 — Due to mold conditions existing throughout the buildings and in particular in the wall cavities and on the ceiling, all the interior wall and ceiling finishes (sheetrock) need to be removed and replaced. Any existing insulation needs to be removed and disposed. Once cleaned, the walls and ceilings should be insulated, new sheetrock installed and finishes applied. This rehabilitation work improves the health and safety conditions necessary to assure safe living conditions. 3 2 — The existing plumbing fixtures were aged, deteriorated and not functioning as designed. All the bathrooms need to be rehabilitated with new efficient water use fixtures that meet the sanitary and safety codes. Based upon the NYS Code Defmition, the work items described above should not be considered part of the Substantial Improvement value calculation. If these items are separated from the total estimated costs for the project the resulting estimate for the proposed improvements would reduce from 28% to 24% buildings value. This further reinforces the statement that the proposed renovation of these structures fall well below the 50% value threshold as related to the Demolition of Structures. Based upon the analysis presented, the real estate documentation and my professional opinion the project should not be considered a "Demolition" in regards to the Town of Southold Code. Project Evaluation --Alteration Level The 2020 Building Code of the State of New York defines Alteration—Level 2 as Scope — Level 2 alterations include the reconfiguration of space, the addition or elimination of any door or window, the reconfiguration of or extension of any system, or the installation of any additional equipment. This proposed project work for these three buildings exactly aligns with this definition. Even though there is substantial interior work to improve the health, sanitary and safety conditions of the facility, the project should be classified as an Alteration—Level 2. Project evaluation Definition of Work.Area Based upon my on-site inspections and my review of the project design plans I was able to evaluate the aspects of this project in comparison to the NYS Work Area definition. The code defines work area as: That portion or portions of a building consisting of all reconfigured spaces as indicated on the construction documents. Work Area excludes other portions of the building where incidental work entailed by the intended work must be performed and portions of the building where work initially intended by the owner is specifically required by this Code. It is noted that for all the structures, the entire structural foundation system, exterior framing and sheathing, roof framing and sheathing, interior floor framing and structural covering, and some interior wall framing all remain as-is and in place. The major rough plumbing infrastructure will also remain in use. 4 The Cabins are one story open structures and the House is an existing one and a half story structure with an open loft storage area. Because these buildings are being renovated in kind to remain as the same use, evaluating this project based upon impacted Work Area is not practical from engineering prospective. Based upon my evaluation of the project conditions and scope it is my professional opinion the project does not have a Work Area that exceeds 50% of the building space. Actually the majority of the work area is in spaces where the activity is required to correcting existing health, sanitary or safety issues. Based upon the my evaluation of the proposed work scope, the work required for safety code reasons and the actual size and configuration of the cabins and house; this renovation does not have a "Work Area" that exceeds 50% of the Building Area. Summary Result - Based upon inspection of this project and to the best of my knowledge, belief and professional judgment: 1 - The statements in the Value Certification Letter dated November 10, 2022 for the construction costs of the planned refurbishment are accurate. 2 - The overall cost of the planned construction will be 28% of the property valuation (less than 50%). 3 - The adjusted cost based upon NYS definitions of the planned construction will be 24% of the property valuation (less than 50%). 4 —According to the NYS Code this project should be classified as an Alteration — Level 2 5 — According to the NYS Code this project does not have a "Work Area" that exceeds 50% of the building area. 6 — The Construction Cost and Real Estate Value Estimates developed are accurate for the proposed project. The assessment of the volume and value of the existing building elements that remain in place is also valid. Based upon the results of these efforts, the determination that this work is not a NYS Substantial Improvement is correct. In addition, the determination that this work is not a Demolition Project as defined by the Town of Southold Code (Chapter 280) is correct. F IVES o� Nicholas J. Mazzaferro, P.E. �* 4 � I o 'ro , 5 0sro Y tl 3 A y Pzl I N N in N- 1 N fN" c5 N , 0w 11J"1 7 �Q1 e'+V C7 i - N S E, PPS a>� N G- PP9 "'u;10 ffm W'Ml v^R a""@ w•^M of uj', .... ... m cel! g :.�..� ..... -.._,�_ r! v ro - r a#'i W. ,�49. � °u"' rn 0 Ln � raw' n Ire u^r t R � , x . V N 00 N N 16' N aN 0 O yCI :SNI O� R: OI t I! G Yh oZ i rn lD N. N jpYN N f.. a 6 I SILVER SANDS 1400 SILVERMERE ROAD GREENPORT, NY 11944 631-513-9019 ADDENDUM TO BUILDING PERMIT APPLICATION Unit 28 WITH RESPECT TO DEC TRUSTEES WATER & SEWER: DEC JURISDICTION —See Attached No Jurisdiction Letter dated 7/27/21 TRUSTEES JURISDICTION —See Attached Letter from Kimack dated November 10, 2022. Additional Administrative Permit being issued. SCWA HOOK-UPS—See Attached Permit issued by SCWA for connection. SEWER HOOK-UPS— Be advised that we did not perform any new work or hook ups and the only work that was done by Skrezec was to inspect and repair a broken line. See Skrezec letter dated November 29, 2022. DESCRIPTION OF THE PROPOSED CONSTRCUTION: For Each of the cottages, the work to be done includes as typical: •Roof replacement. •Repair or Replace damaged/rotted framing where needed.. •Upgrade insulation. •Replace/upgrade existing plumbing risers and fixtures. •Replace/upgrade existing electrical service and rough-in. •Replace/upgrade existing HVAC. •Replace interior wood flooring. •Replace sheet rock and trim. •Repair or Replace screened-in porches, as needed. •Repair foundation cracks, as needed. •Replace windows and doors in kind. •Repair or Replace existing siding. CERTIFIED COST OF THE PROJECT: $207,856.00 (37% OF THE COMBINED STRUCTURES VALUATION WHICH TOTALS $561,058.00) AS DETERMINED BY CERTIFIED VALUATION OF NEWMARK VALUATON AND ADVISORY CO. NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL ENTAL C NSE VATICN DIVIR40ii of InvItanniontol Pomiltb,Region 1 SUNY cin Stony Brook,50 Gicle Road.Stony Brook,NY 11790 P;(631)444-03651 F;(631)444-0360 www'doc:ny ouv LETTER,OF NO JURISDICTION TIDAL WETLANDS ACT July 27, 2021 Alexander Perros Silver Sands Holdings I LLC 19215 Soundview Ave. Southold, NY 11971 Re: Application #1-4738-04898/00001 Silver Sands Holdings I LLC Property: 1100, 1220 & 1135 Silvermere Road SCTM# 1000-47-2-13, 14 & 15 Dear Alexander Perros: Based on the information you submitted the Department of Environmental Conservation has determined that the portion of the above properties landward of the functional bulkheads greater than 100 feet in length, as shown on the survey prepared by Young and Young, last revised 5/17/2022, which was constructed prior to August 20, 1977 as evidenced on Tidal Wetland Map#720-552, are beyond the jurisdiction of the Article 25 Tidal Wetlands Act. Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661), no permit is required to conduct regulated activities landward of that bulkhead. Be advised, no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all precautions are taken to prevent any sedimentation or disturbance within Article 25 jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the jurisdictional boundary and your project (i.e. a 15' wide construction area) or erecting a temporary fence, barrier, or hay bale berm. This letter shall remain valid unless site conditions change. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. Sincerely, 9 .5 ��- Kevin Kispert Permit Administrator cc: BMHP File .NA yg1111I Depa "Ind tit Conservation N. J. MAZZAFERRO P.E. PO Box 57, Greenport, N.Y. 11944 Phone - 516-457-5596 Consulting Engineer March 13, 2023 Design, Construction Inspection Silver Sands Holdings 1, LLC 1400 Silvermere Road, Greenport,NY 11944 Re: - Energy Evaluation- Costs for Refurbishment of Cabins 26-27-29 House Unit 28 Tax Lot— 1000-047-02-13 (1100 Silvermere Road, Gpt,NY 11944; Cabins 26-27,29 House 28) Property Occupancy Code—Comm—Motel/Cabins—NYS Building Code Section 310.2 Project Category—Alteration 2 -NYS Existing Building Code Section 603 Tax Info—Comm- Motel—3 Buildings on 0.50 acres—Pre-Existing 1957. CofO's Exist for Building 29, 11/27/57 —Addition, 11/21/84—Green House. No other Cofo's. On 3/14/23 I reviewed the project plans for the three (3) Cottages on Lot 13. My review included discussions with the Project Manager (Alex Perros). The purpose of this effort was to determine if the proposed construction complies with the 2020 NYS Building Code (Energy Conservation), in particular the 2018 IECC. The proposed work has been determined to be an "Alteration-2" as defined by the NYS Code. The elements reviewed for energy conservation include the exterior envelope, fenestration and HVAC System. House Exterior Enyelope. The exterior envelope includes the roof, ceiling walls and floor. The insulation provided in the design is as follows: Element ExistingProposed Roof Structure Batts—(R-11) Batts—(R-49) New Ceilings Batts—(R-11) Batts—(R-30) New. Walls - ExteriorBatts—(R-11) Batts—(R-15) New Walls-..Interior None Batts—(R-11) New-Sound Floors None Batts—(R-22.5) New Spray-Max Depth Box Beam None Spray Foam—R-30 Overall Substandard Exceeds Requirements 1 w I find this proposed design for the exterior building envelope to be compliant with the Code. This finding is based upon Code Section C503- Alterations, Item C503.1 General. The design building envelope meets the requirements of this Code Section as follows: -After the Alteration the building will be more compliant with the Code. - After the Alteration the building will use less energy for routine operational needs. - The Alterations do not create any hazardous conditions or overload any building systems - All exposed cavities in the roof, ceiling, walls and floors will be 100% filled with insulation. Fenestration: The fenestration includes the doors and windows throughout the Cabin and House Structures. As part of this alteration all the doors and windows are being upgraded. The doors will be Thermatrue or Anderson 400 Series. The windows will be Anderson 200 Energy Star Series. The new replacement doors and windows in the design all have a "u" factor in the range of 0.30 to 0.32. The Prescriptive Section of the Code requires: Windows - to meet Section C402.4 Table C402.4 the "u" factor is 0.45 Doors - to meet Section C402.4.5 Table C402.1.4 the "u" factor is 0.61 The Thermatrue Doors have a"u" factor of—0.30 (or less) The Anderson 400 Series Doors have a"u" factor of- .032 The Anderson 200 Series Windows have a"u" factor of- .032 I find this proposed design for the fenestration to be compliant with the Prescriptive Code. This finding is based upon Code Section C402.4 and C402.4.5. The design for the window and door replacement meets the prescriptive requirements of the Code. HVAC: The HVAC Systems includes the new "split units" proposed for the House. The use of split units will provide a more efficient, highly controllable system. The system provided in the design is: Cottagg Conditioned Space Proposed Unit Cabins 26-27,29, Hse 28 All Rooms ComfortStar Unit—Various Ratings 2 I find this proposed design for the HVAC System to be compliant with the 2018 IECC, in particular Section C403.3.2 HVAC Equipment Performance Requirements. This finding is based upon the efficiency ratings and vast operational improvement of the newer systems. The building mechanical system meet the requirements of this Code Section as follows: -After the Alteration the buildings will be more compliant with the Code. - After the Alteration the buildings will use less energy for daily operational needs. - The Alterations do not create any hazardous conditions or overload any building systems Lighting The Interior and Exterior Lighting Systems include all new LED luminaires. The interior lighting proposed for the cottages will be 100% LED, decreasing the amount of energy used, reducing the interior heat load and providing a longer unit life cycle. The exterior lighting proposed for the cottage area meets the code requirement for visibility while conforming to the Dark Sky requirements of Southold Town. The exterior fixtures will be 100% LED, decreasing the amount of energy used and providing a longer unit life cycle. The systems provided in the design are as follows: -After the Alteration the buildings will be more compliant with the Code. -After the Alteration the buildings will use much less energy for daily operational needs. - The Alterations do not create any hazardous conditions. Nicholas Mazzaferro, PE of iew . 051()' � �? 'FE 4 3