HomeMy WebLinkAbout48582-Z ��p�guFFOI Town of Southold 3/4/2023
a P.O.Box 1179
o53095 Main Rd
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 43876 Date: 3/4/2023
THIS CERTIFIES that the building GENERATOR
Location of Property: Private Rd,Fishers Island
SCTM#: 473889 Sec/Block/Lot: 3.-5-3
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
11/14/2022 pursuant to which Building Permit No. 48582 dated 12/13/2022
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
accessory generator as applied for.
The certificate is issued to Wilmerding,Charles&Anne
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 48582 12/13/2022
PLUMBERS CERTIFICATION DATED
Auth ized Signature
o�SUFFe��,co TOWN OF SOUTHOLD
BUILDING DEPARTMENT
y z TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 48582 Date: 12/13/2022
Permission is hereby granted to:
Wilmerding, Charles
201 S Radnor-Chester Rd
Villanova, PA 19085
To: Install accessory standby generator at existing single family dwelling as applied for.
At premises located at:
Private Rd, Fishers Island
SCTM # 473889
Sec/Block/Lot# 1-5-3
Pursuant to application dated 11/14/2022 and approved by the Building Inspector.
To expire on 6/13/2024.
Fees:
ACCESSORY $100.00
ELECTRIC $85.00
CO-RESIDENTIAL $50.00
Total: $235.00
Building Inspector
o��OF SOUTyoI
� o
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 �Q roger.richert(cD-town.south old.ny.us
Southold,NY 11971-0959 Q�yCOUn��
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Charles Wilmerding
Address: Private Road City: Fishers Island St: New York Zip: 6390
Building Permit#: 48582 Section: 3 Block: 5 Lot: 3
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
contractor: DBA: Z&S Contracting License No: 4798-ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement X Service Only
Commerical Outdoor X 1 st Floor Pool
New X Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel 1 A/C Blower Range Recpt Fluorescent Fixture Pumps
Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks
Disconnect Switches Twist Lock Exit Fixtures 11 TVSS
Other Equipment: 22 KW stand by generator with 200a disconnect
Notes:
Inspector Signature: Date: December 13 2022
81-Cert Electrical Compliance Form.xls
�T
SOUIyo<o
# TOWN OF SOUTHOLD BUILDING DEPT.
`ycoutme�' 631-765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] IN ULATION/CAULKING
[ ] FRAMING /STRAPPING [ FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: a� • U'
DATE INSPECTOR
FIELD INSPECTION REPORT DATE COMMENTS
FOUNDATION (1ST) y
------------------------------------
COOC
FOUNDATION (2ND)
z
O
ROUGH FRAMING&
PLUMBING
1
INSULATION PER N.Y. '3
STATE ENERGY CODE
FINAL
ADDITIONAL COMMENTS
C)
0
z
H
x
d
b
H
. lr
r
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
T d
Town Hall Annex 54375 Main Road P_ O. Box 1179 Southold,,NY 11971-0959
y *
Telephone(631) 765-1802 Fax(631)765-9502 httpW:
saLwwwsoutholdtawnnv: ov
�.
pp¢ •4Pov-n.t•
1.
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use only _
�In
PERMIT NO. _ Building Inspector:,_ �"�,�
NOV 1 4 292
Applications and forms must be filled out in their entirety.Incomplete
applications will not be accepted. Where the Applicant is not the owner,an '�n
Owner's Authorization form(Page 2)shall be completed.
Date: 0 31
OWNER(S)OF PRO RTY:
y Name:
Chu. - W1 I we i SCTM#1000-
i Project Address:1361 C.A. 12— I
Phone#: V Xq 1, 2-3 S-5- Email:
p
w Mailing Address: 2j 1 S. K ,� y ,_ ( QhG Vd1, PA- I lO
� �/� 1.�'l �est-""
CONTACT PERSON:
Name:
ottki Coy+- (-LoMailing Address:
Address: 5"A5C O `S 'S
Phone#: Email: 1
I -2 9� 7 ?.5� ZQ�Q 4 tyLt,t ,Cant
DESIGN OR SSIONAL INFORMATION:
s
Name:
f
Mailing Address:
I Phone#: Email:
I
CONTRACTOR INFORMATION:
Name: -t-- Co l� /
Mailing Address: �I O �Cj� a �S 1
Phone#: 1 -7 YS7 Email: cot
J C.�TlI
IDESCRIPT11bill OF PROPOSED CONSTRUCTION
ON tructu a OAddition Alteration ❑Repair ❑Demolition Estimated Cost of Project:
ther 1+^ S 7ty 0 o DU
3 Will the lot be re-graded? Oyes o Will excess fill be removed from premises? OYes ONO
l
t
E
F
T
k
PROPERTY INFORMATION
Existing use of property: �eg t ,h f 6 Q Intended use of property: ax t
Zone or use district in which premises is situated: Are there any covenants a d restrictions with respect to
(�
x
R 1 7-Vthis property?.[;JYes QNo IF YES,PROVIDE A COPY.
11 Check Box After Reading: The owner/contractor/deslpi Professional h responsft for all drainage and storm water Issues as provided by
i chapter 236 of the Town Code.APPLICATION is mEREBY MADE to the BWWng Deputment for the hsuacci of a Mddng permit pursuant to the Baildin j Zone
I Ordinance of the Town of southow,suffoik County,New York and other applicable Laws,Ordinances or Regulations„for the aanstructlon of buildings,
nddithum alterations or for removal or demolition as herein described.The applicant agrees to comply with OU appocMe laws,ordinances,building code,
housing ends and regulations and to admit authorized inspectors on premises and In buildings)for rNcessary inspections,False statements made herein are
punishable as a Dass A misdemeanor pursuant to Section 210AS of the New York State Pena!Law.
Application Submitted By(p ript name): p (�pryrn LLO ❑Authorized Agent ❑Owner
fi 1 1
Signature of Applicant: Date:
a. STATE OF NEW YORK)
d'
SS:
COUNTY OF (GPj'!?LdC I
��L` Cosi`'(-0 being i g dui y sworn,deposes and says that(s)he is the applicant
(Name of Individual signing contract)above named,
(S)he is the ( (, Gf_�
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained In this application are true to the best of his/her knowledge and belief,and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
—e—Clay of �yVg�-t 20 ZZ
N ryPublic
{ t Hc1P z zZ,5 P-3
i
i PROPERTY OWNER AUTHORIZATION
(Where the applicant is not the owner)
I, C r lk -g Wjmudi"O't esiding at AV ) �!r
V mov R"
� ��g7 do hereby authorize (,Olaf / �II/!� .- snq to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature ate
C3V YV 1fin
Print Owner's Name
2
'lam
SO F04 -c;,. BUILDING DEPARTMENT-Electrical Inspectol Vol ' 4 A22
CI` TOWN OF SOUTHOLD
{ Town Hal(Annex-54375 Main Road -PO Box 1179
�A. Southold, New York 11971-0959
� Telephone (63.1)7654802 FAX(631)765-9502
rogerr -southoldtownny.gov w seand(a)southoldtownny gov
APPLICATION._FO.R ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date:
Company Name: 7 3 `-14` ►-,
Name:
License No.: _1 q "11'1 email: 7-
�
Phone No: - request an email copy of Cerfffic-atg of Compliance
Address.:
, LXAkido-
JOB SITE INFORMATION (All Information Required)
Name:
Address: 1 301
Cross Street*,
Phone No.: o Zq 1— 5 - ----
Bldg.Permit#: email:
Tax Ma 'District: 1000 Section: 3 Block: 5- Lot: 3
BRIEF DESCRIPTION OF WORK (Please Print Clearly)
Check All That Apply:
Is job ready for inspection?: S []NO ❑Rough In [ginal
Do you need a Temp Certificate?: ❑YES ❑NO Issued On
Temp Infor-mations (Al Information PegUiPed)
Service Size [D1 Ph ❑3 Ph Size: A # Meters Old Meter#
❑New Service ❑ Service Reconnect F]Underground [-]Overhead
#Underground Laterals []1 2 H Frame❑Pole Work done on Service? ❑Y ❑N
Additional Information:
PAYMENT DUE WITH APPLICATIQ --- -
r'
Electrical inspectlon Form 2020.xisx
PROVIDE 2
ON SITE SEPTIC SY 7'ct
LIMITS OF
(SEE
'i) LEACHING POOLS
CLEARING
DETAIL
to
EXPANSION AREA
REMOVE DECK
PROVIDE
DISTRIBUTION
J,
IBENCHMA : %:,
'
BOX (SEE DETAIL) J
PROPOSED
Dl a ID
SCREENED
PORCH
. .........
Rr
RO
T
M
AINI 4,04v TI
...........
COWM6110141 /EXISTING 2ua 'q
N
Toexpi
CKPiLE STORY
BEDROOM
SIDE
-"AREA
NCE
P 0 DE 1500
EMAIN) rn
1541tiqlIkk -JAN
K (SEE DETAIL)
sr
S i ; PARKING—LOAM
REMOVE GRAVEL
56
AND SEED
JJON -OF EXISTING
EXISTING
TIC SYSTEM—
FROM SITE WATER SERVICE
'SO I'm-080 . , . E
{SUMP ANV"R.MOW
PROVIDE DRY WELLS
FOR ROOF DRAINAGE
48
mrp)-3 DRY WELLS'
S)
MAPLE
F.
(SEE DETAIL) 27"
rl
PROVIDE 14V Liy
DK AN' MAPLE
FILLED
25
EXISTING I STORY
r,, STORAGE BUILDING
TO REMAIN
0*
(DRY BUILDING)
STAGING
AREA
11 lwO
E
PROVIDE 12"
lei
ING
LANDSCAPED CHER Y
ISLAND
PROVIDE
CONCRETE
ONS UC1164
WASHOUT PIT
ENTRANCE
(SEE DETAIL)
SEE DETAIL)
IRON
EXISTING 6" WATER MAIN S 431.17
W
W 57SZ84
... .......
hR DG
I E
1
-4q
6
N
SHERS J$LAN OPMENT
CORP
3p
APPROVED AS NOTED OCCUPANCY OR
DATEAg?.. 3 USE IS UNLAWFUL
FEE `ABY: WITHOUT CERTIFICATE
NOTIFY BUILDING DEPARTMENT AT OF OCCUPANCY
631-765-1802 8AM TO 4PM FOR THE (� ANCY
FOLLOWING INSPECTIONS:
1. FOUNDATION-TWO REQUIRED
FOR POURED CONCRETE
2 ROUGH-FRAMING&PLUMBING
& WSULATION
4► FINAL-CONSTRUCTION MUST
BE COMPLETE FOR C.O.
ALL CONSTRUCTION SHALL MEET THE
REDUIREMENTSOFTHECODESOFNEW ALL CODES OF
YORK STATE. NOT RESPONSIBLE FOR NE:VV YORK STATE & TOWN CODES
DLWAORCONSTRUC70NERRORS AS REQUIRED AND CONDITIONS OF
SOUTHOLD TOWN ZBA
SOUTHOLD TOWN PLANNING BOARD
M SOUTHOLD TOWN TRUS T C75
SCI NPAI I N,'l4.5,DEC
RETAIN STORM WATER RUNUF
PURSUANT TO CHAPTER
OF THE TOWN CODE.
GENERAC®
20/22/24 kW GUARDIAN® SERIES _
Residential Standby Generators
Air-Cooled Gas Engine
Standby Power Rating ,
INCLUDES: G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz
• True Power"" Electrical Technology G007042-10,G007042-11,G007043-10,G007043-11(Aluminum-Bisque)-22 kW 60 Hz
G007209-10,G007210-10(Aluminum-Bisque)-24 kW 60 Hz
• Two-line multilingual digital LCD EvolUtionTM controller
(English/Spanish/French/Portuguese)
• 200 amp service rated transfer switch availablePV
• Electronic governor 4 ';
• Standard Wi-Fi®connectivity _
• System status&maintenance interval LED indicators t
• Sound attenuated enclosure
• Flexible fuel line connector a
• Natural gas or LP gas operation t ._ �• GENERAC -.i
• 5 Year limited warranty
• Listed and labeled for installation as close as 18 in(457 mm)to a
r:
structure.*
`Must be located away from doors,windows,and fresh air intakes and in
accordance with local codes. Product shown with optional fascia Idt
CONusor CLIS�TEUU8 QUA n 1
Note:CETL or CUL certification only appplies to unbundled units and units packaged
with limited circuit switches.Units pac9ged with the Smart Switch are ETL or UL
certified in the USA only.
FEATURES
O INNOVATIVE ENGINE DESIGN &RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod-
Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI-
the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge
rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%.
O TRUE POWER'"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network
form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small-
allows confident operation of sensitive electronic equipment and micro-chip based est electronic component.
appliances,such as variable speed HVAC systems.
O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with
✓ PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system
compatibility.
O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby
generators, Mobile Link WI-Fi allows users to monitor generator status from any-
where in the world using a smartphone,tablet,or PC.Easily access information such
as the current operating status and maintenance alerts. Users can connect an
account to an authorized service dealer for fast,friendly,and proactive service.With
Mobile Link,users are taken care of before the next power outage.
'IGENEPROM00(9
AC (2
•,w+waauHoaras.aaam
GENERAC®
20/22/24 kW Features and Benefits
_ Engine
• Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly
rings help the engine run cooler,reducing oil consumption and resulting in longer engine life.
• "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance These features combine to assure smooth,quick starting every time.
• Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine
' life.Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown Prevents damage due to overheating.
Generator
• Revolving field Allows for a smal ler,lightweight unit that operates 25%more efficiently than a revolving armature generator.
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability.
• Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes.
• EPA Certified for non-emergency applications Allows unit to be used for demand response applications(excluding 20 kW units).
• UL 2200 listed For your safety.
Transfer Switch (if applicable)
• Fully automatic Transfers vital electrical loads to the energized source of power.
• NEMA 3R Can be installed inside or outside for maximum flexibility.
• Integrated load management technology Capability to manage additional loads for efficient power management.
• Remote mounting Mounts near an existing distribution panel for simple,low-cost installation.
Evolution— Controls
• AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition.
• Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences.
• Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations.
• Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage.
• Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home.
• Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds.
• Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute.
• Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for
5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
• Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries.
• Main line circuit breaker Protects generator from overload.
• Electronic governor Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding
winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access
to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries.
• Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure.
GENERAC®
20/22/24 kW Features and Benefits
Installation System
• 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
• Integral sediment trap Meets IFGC and NFPA 54 installation requirements.
Connectivity(Wi-Ff equipped models only)
• Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for '
complete peace of mind.
• Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.
• Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due.
• Monthly report with previous month's activity Detailed monthly reports provide historical generator information.
• Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.
• Weather information Provides detailed local ambient weather conditions for generator location.
GENERAC®
20/22/24 kW Specifications
Generator
Model G007038-1 6007042-10 G007038-3 6007042-11 G007209-10
G007039-1 G007043-10 G007039-3 G007043-11 G007210-10
_
0 (22 (20 kW) (22 kW) (24 kW)
_
Rated maximum'continuous power capacify,(L`P} f s,; 20 000 Watts 22;000_Wattsl, ?.20;000 Watts 22;000 Watts 24 0OO Watts' 't
Rated maximum continuous power capacity(NG) 18,000 Watts' 19,500 Watts'_ 18,000 Watts' 19,500 Watts" 21,000 Watts' 1
Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83,3/75.0 91.7/81.3 _100/_8 7.5
[Total Harmonic Distortionw-_._ _ ., . ,
Less.than 5%
Main line circuit_breaker _ 90 amp 100 amp T 90 amp — 100 amp 100 amp
Phase_ _.�__.w_...- _,.b._.�_ .___.,. .._ ..._._.�__ �_.._ _ .. ..�. 1 M. 1-
Number or rotor poles_ 2
60 F1z
Power factor 1.0
;Battery requirement(not includedj, vT 7_? _ ,"_$ _`- _ '' �^ 'T 12 Volts;.6r'oo�-26R 540 CCA minimum gr Grod 35AGM 850`CCA minimum
Unit weight(lb/kg) 448/203 466/211 436/198 445/202 455/206
Drmenswns
Ax-WxN in/cm" ' 48-x 25 z29`/121,9x63.5'x73.7 - X
Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load"` 67 67 67 67 67
Sound out ut in d8 A at 23 R 7 mj with eneratorm Quiet-Test low-s eed exercise mode 55 57 55 57 57
' TM
Exercise duration 5 min
Engine
Engine type GENERAC G-Force 1000 Series
Lidumher of cylinders'`m - 2
Displacement 999 cc
__.__._ w.. ._._..-._ _ _ _w_. - „__.... .___ Alumfn_umw/cast iiron sleeve
Valve arrangement Overhead valve~
[Igmhonsystem _,_..__ __ Solid-state w%magneto,
Governor system Electronic
Starter 12 VDC
fOd apacfty mcludmg"filter, '>__<r_ M °kip" l 9 qt/18 L
Operating rpm -__. -.� ..,,_-_.,_-.._.. _-,.._.�_.... ...__ .__ ' 3,600
Fuel consumphan _
Natural gas ft3lhr(m3/hr) j
f s 1/2 Load 204(5 78) 228(6:96) 164(4 64) 203(575)
I F' 'Load 301-(8 52) 327(9.26) 287(8.13) 306(P.66) }
�uq"d propane fts/hr(gal/hr)[Uhrj
f 1/2 Load 87(2.37)[8 99] _ 92(2 53):[9 57] '86(2 36)[8.95] 92(2 53)[9.571' :f
FuIII d 130(3.56)[13!48 ,142(3 90)[74 77) 136(1,74)[1415] 142(3.90),114.77f t
Note:Fuel pipe must be sized for full load.Required fuelpressureto generator fuel inlet at all load ranges-3.5-7 in water column(0,87-1.74 kPa)for NG, in water column(2.49-2.99 kPa)for LP
gas.For BTU content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG).
Controls
Two-line plain text multilingual LCD Simple user interface for ease of operation.
Mode buttons:'AUTO u.y_t - Automatic stall on'utility failure.Weekly,61-weekly,4o�Monthly'selectable exerciser rc_
MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place.
z „r"" r y- -°'Stops unit.Power is,removed Control and ciiarger still operateT�
Ready to Run/Maintenance messages Standard w
[Engine run hours mdicahon- Standard
Programmable start delay between 2-1500 seconds _ Standard(programmable by dealer only)
[UtflityVolrageLoss%RetumtoLr@yadjusfatile(brownout'sethng) -- M -�
Future Set Capable Exerciser/Exercise Set Error warning Standard
Y
IRuNAlarm/Maintenance logs , 50 events each
Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration).
Starter lockout • __.__ _. .., ... _ ._._._..._., _.,__--u ___-._ ._w__,Starter cannot reengage unhl0'sec after engine has stoppedP _.. - -_
Smart Battery Charger _ - Standard
[Charger FaulUMissin AC warnin m' k
Standard
t
Low Battery/Battery Problem Protection and Battery Condition indication Standard
Automatic Voltage Regulati0--h--w-ii,hOver and Under Voltage Protection" Standard
Under-Frequency/Overload/Stepper Overcurrenl Protection _ Standard
(Safety Fused/Fuse Problem Protection._. . _._
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard
Overcrank/Overs eed(@ 72 Hz)/ m 5ehse Loss Shutdown
' .T-
_ Standard
High Engine Temperature Shutdown _ Standard
Yntelnal,FaulUlncorcectWiring protection M."„ x w 7,-:7777'_777 -'''-Standard 77-
4{ A
Common external fault capability Standard
Field u radable tumware - - `•�. _ _
Rating definitions-Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed.No overload capability is available for this rating.
(All ratings In accordance with BS5514,ISO3046,UL2200,and DIN6271).
Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases
approximately 3.5%for each 1,000 ft(304.8 m)above sea level;and also will decrease approximately 1%for each 10 OF(6°C)above 60 OF(16°C),
"'Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on Installation parameters.
GENERAC®
20/22/24 kW Switch Options
Service Rated Automatic Transfer Switch Features G007039-1,G007039-3(20 kW)
• Intelligently manages up to four air conditioner loads with no additional hardware. Model G007043-10,0007043-11(22 kW)
G007210-10(24 kW)
• Up to eight additional large(240 VAC)loads can be managed when used in conjunctionNO;of.poles y �2
with Smart Management Modules(SMMs). Current rating(amps) _. -"`" 200 — _..._.
• Electrically operated,mechanically-held contacts for fast,clean connections. Volta a rahn (VACj: • 120/240,10
g g
• Main breakers are rated for 80%continuous load. Utility voltage monitor(fixed)*
-Pick-up 80%
• 2-pole,250 VAC contactors. -Dropout 65%
• Service equipment rated,dual coil design. [Return toYUtility'' _ m YAp_43 sec 4
_ _
• Rated for both aluminum and copper conductors. EnclosurETL or ULe a Iisted NEMA 6 Standard-,R _�}
• Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range, _250 MCM,-#6 4
*Function of Evolution controller
Dimensions Exercise can be set to weekly,bi-weekly,or monthly
vri
200 Amps 120/240,1 o
Open Transition Service Rated
Height Width Depth
H1 H2 W1 W2
in 26.8 30.1 10.5 13.5 6.9
cm 67.95 76.43 26.67 34.18 17.5 ez "'
Wire Ranges
Conductor Lug Neutral Lug Ground Lug
250 MGM-#6 350 MGM-#6 2/0-#14
GENERAL®
20/22/24 kW Available Accessories
7 _77 7
7"
Modeh#
Product
ioi6 C Description
13007101-0 lBattery Pad-Warmer PPad warmer rests under the battery.Recommended for use if temperature regularly falls below d (4 q.(Not nec-
�essary for use with AGM-style batteries).
Oil 13007103 Warmer (Oil slips_Fi direcfl�over the oil iilir_14_ec 6im_rriWri—de jloi i�jf temperature regularly tgc�iWw Fr'(-1 R
_ 'W _6Wa&iWWir i�e_F Is_iW We'l W extreme _
-1 �Breather Warmer lj�wiif4j'ap applications.For use with Evolution controllers only in climates Where
heavy icing occurs.
jG0056-21 0------Auxiliary—Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be
;Contact Kit needed Not compatible with 50 amp pre-wired switches.
7-0-Bisque iFascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured_�,
_,._,_ _,_ Jappearance as well as offering protection from rodents and insects by covering the lifting holes located in the base.':_ 11
G0057036 important to touch up the paintto protect from fu1_urCc_oTF6_SIOn.
-Bisque Paint Kit lf-t—he—gen—er,a—t,o,-r"e,n—c,lo—sure—is scratched or
The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
'iG006485-0 [Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a
Generac automatic standby generator(oil not included).
jG007005-0 iffi-l'i LP Tank Fuel Level The Wi-FI enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the
Monitor iLP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta-
Itus alerts are available through a free application to notify users when the LP tank is in need of a refill.
G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large eiec-
G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SIMM'S can reduce
00 the overall size and cost of the system.
'j007 69-0-4G LTE ;Mobile Linkt Cellular IThe Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using
d00
G71170_0-Wi-FV (Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us-
Ethernet lers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,
iusers are taken care of before the next power outage.
RG007220-0 Bisque Base Plug Kit lBase plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured
lappearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Ki
lcontains four plugs,sufficient for use on a single air-cooled home standby generator.
Dimensions & PCs
Model UPC 637.6 mm 1218 mm
[25.1 In] [48.0 1n]
G007038 696471074185
G007039 696471074192 0
G007042 696471074208
G007043 696471074215
G007209 696471071511 727.2 m.
[28.6 In]
G007210 696471084801
0
848 mm 1232 mm
[48.61n1
LEFT SIDE VIEW FRONT VIEW
Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
GENERAC® Generac:Power Systems,Inc. - S45 W29290 HWY.59,Waukesha,WI 53189 - generac.com
- M (W022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Part No.A0000937814 Rev,E 03/15/2022