Loading...
HomeMy WebLinkAbout45620-Z J""'tet opo CpG,� Town of Southold 3/4/2023 P.O.Box 1179 W 53095 Main Rd Southold,New York 11971 t CERTIFICATE OF OCCUPANCY No: 43 889 Date: 3/4/2023 THIS CERTIFIES that the building ALTERATION Location of Property: 90 Dawn Dr,Greenport SCTM#: 473889 Sec/Block/Lot: 35.-5-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/30/2020 pursuant to which Building Permit No. 45620 dated 12/29/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: partially finished basement(recreation room and gym)to existing single family dwelling as applied for. The certificate is issued to Ryan Jr,John of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45 0 5/27/2022 PLUMBERS CERTIFICATION DATED 2/16/2023 ich idolfi AW� Aori ed S'g tore =1'' TOWN OF SOUTHOLD SUFFoI,r�,Gy BUILDING DEPARTMENT y TOWN CLERK'S OFFICE `oy • oma } SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45620 Date: 12/29/2020 Permission is hereby granted to: Ryan Jr, John 90 Dawn Dr Greenport, NY 11944 To: construct additions and alterations (finish basement) to existing single-family dwelling as applied for. At premises located at: 90 Dawn Dr, Greenport SCTM # 473889 Sec/Block/Lot# 35.-5-11 Pursuant to application dated 11/30/2020 and approved by the Building Inspector. To expire on 6/30/2022. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $543.60 CO -ALTERATION TO DWELLING $50.00 Total: $593.60 Buil in .spec pF SO!/jyQlo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlinCaD_town.southold.ny.us Southold,NY 11971-0959 �Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: John Ryan Jr Address: 90 Dawn Dr city;Greenport st: NY zip: 11944 Building Permit#: 45620 Section: 35 Block: 5 Lot: 11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: GJS Electric License No: 4839ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service X Commerical Outdoor X 1st Floor Pool New X Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt 19 Ceiling Fixtures 1 Bath Exhaust Fan Service 3 ph Hot Water Gas GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser 1 Single Recpt Recessed Fixtures 22 CO2 Detectors Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt 30A Emergency FixtureTime Clocks Disconnect Switches 12 Z LED 3 Exit Fixtures Pump 1 Other Equipment: Humidifier, Mini Split, 200A Panel 54 Circuit/ 54 Used Notes: Finished Basement Inspector Signature: Date: May 27, 2022 S. Devlin-Cert Electrical Compliance Form pF SOU�yOIo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 L Southold,NY 11971-0959L OyCOU '�, y �� �� FEB 2 8 2023 BUILDING DEPARTMENT St@It,L ING DEPT TOWN OF SOUTHOLD 70WN OFSOUT9-OLD CERTIFICATION Date: Building Permit No. (�Z J Owner: 1 'N Ij (Please rint) Plumber: ( ` (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead.. umbers Signature) Or Sworn to before me this :41 day of EkL To a 20 _ Notary Public,s�uf-4 1 k County Michael Margulies Notary Public;SEate'of Neva York No.01MAS"3509 Qualified in St,jfFolk bounty Commission Expirjs"Nov.19,202ja pF 50UTy�� * # TOWN OF SOUTHOM BUILDING DEPT.- 765-1802 EPT.765-1802 INSPEC ION [ ] FOUNDATION 1 ST [ UGH PLBG. [ ] FOUNDATION 2ND- [ INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ j FIREPLACE &.CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS:. DATE [D INSPECTOR OF SOUTyO� L U2 [ 00 * # TOWN OF SOUTHOLDI BUILDING DEPT. courm, 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ .] FIREPLACE-& CHIMNEY j ] -FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: 4,y r-s DATE It7 INSPECTOR t� OF soOTyO� # TOWN OF SOUTHOLD BUILDING DEPT. t� com, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Fes` ZZm;�noc z•• ef-au-I&E M-eu. ase cs s p6x becf- F E6--Mec--ti 671ZI S y b 6 DATE INSPECTOR 4141 OF SOUIyo 16) �� 1 v l v�� ,• # # TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) `[A ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ ] PRE C/O [ ] RENTAL REMARKS: d" a ryiGe DATE 27122 INSPECTOR �oy>�UF SOUIyo� # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATIOWCAULKING [ ] FRAMING /STRAPPING [ NAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATEAkqINSPECTOR )3P P (631)650=6666 V(631)1'650-6667'., ', .�► -C(516) 658-0325. ,r TO DD N E L L www.tocarch„itects.com A.;R,C H 6 T,E C T, P. C. - ,todd@tocarchit6cts.com May 22, 2021. " Town of Southold . Building department " Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971=0959 Re: Ryan:Residence 100•Dawn Drive , . 'Greenport, NY 11944 To whom it,may concern: ; ' ,Please be advised that we a are submitting plans to amend,the permit.for the property.The changes are. as follows: • Egress.window location-and well changed from the fromthe side facing Dawn Drive to the side facing Wiggins Lane. ; • The a/c units are being relocated to the back side of the house to make room for the new egress - window well. • A storagecloset is being added in th,e unfinished part of the'basement. Please feel free to contact our office with any questions`or concerns,you may have. ; Very tru�rrsiursr±_�_ Tod&d nr � -935 TOC:cm • • • ice`V ' � t " ROUGH FRAMING& PLUMING • • B d G �g t3 9. � — — ted, R TOWN OF SO-gTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined ,20 � Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved ,20 Mail to: Disapproved a/c Phone: Expiration ,20 Building lnsp6ctor APPLICATION FOR BUILDING PERMIT Date September 2nd 20 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. 1 b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. ,e;No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations,9- or removal or demolition as herein described. The applicant agrees to-con Ly,vaitl�'��1 �Dl "able Iaws, ordinances,buil mg c de,housing code, and regulations, and to admit authorized inspect�r on*euil ' g for necessary ins ection . UU NOV 3 0 2020 (Signature of applicant orT-11�c ' orporation) 1�`aTII'- •F ;;ate;,;; ';�, PO Box 2120 Greenport, NY 11944-0972 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder OWNER Name of owner of premises JOHN RYAN (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. ' Other Trade's License No. 1. Location of land on which proposed work will be done: 100 DAWN DRIVE, GREENPORT House Number Street Hamlet County Tax Map No. 1000 Section 35 Block 5 Lot l l S Subdh,dsion CLEAVES POINT SECTION NO.3 Filed Map No.4650 Lot 75&76 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy RESIDENCE b. Intended use and occupancy RESIDENCE 3. Nature of work(check which applicable):New Building Addition Alteration x Repair Removal Demolition Other Work �o / (Description) 4. Estimated Cost � ��c� Fee 4Z00 "�' �•'�C �3d(7 A (To be paid on filing tht application) 5. If dwelling, number of dwelling units A Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify,nature and extent of each type of use. d )A 7. Dimensions of ex*sting structures, if any: Front 66 ,1 Rear Depth 5 '� Height Number of Stories I �f Dimensions of same structure with alterati s or additions: Front (0�•� Rear Depth 35-3 Height Number of Stories � 8. Dimensions of e tire new construction: Front /A Rear Depth Height Number of Stories 9. Size of lot: Front L4�• Rear 1 '54 -12 Depth D,0 10. Date of Purchase 12-cYl Name of Former Owner L I S /a LS 0Z A 6 4-- 11. Zone or use district in which premises are situated iz. 40 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO X 13. Will lot be re-graded? YES NO X Will excess fill be removed from premises? YES NO X 14.Names of Owner of premises JOHN RYAN Address PO Box 2120 Greenport,NY 11944.0972 phone No. 917-921-0000 Name of Architect Todd O'Connell Address 1200 Veterans Mem Hwy Hauppauge NY 11788 Phone No 631-650-6666 Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO X * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO ✓ * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUN O ' �`'`'� being duly sworn, deposes and says that(s)he is the applicant ame of individual 'ig ing contract)above named, (S)He is the lV U0VVA--- (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewit . Swo fore me t day ofNA20 2O EMILY J REEVE Notary Public,State of New NA RE6059270 ry ublic ©uallfled In Suffolk County Signature of Appli ant My commission expires July 23,2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) residing at Pb Z.I1-b C ver,, ►�-� l4 U L( (Print property owner's name) (Mailing Address) Lbo t �,sZ�r• 17� Y� l do hereby authorize , ConAt (t (Agent) to apply on my behalf to the Southold Building Department. /0 (O per's Signature) (Date) ,-A,l 9\4 12 V\. (Print Owner's ame) ChG'"n'9�-d SUa � C4 ILDING DEPARTMENT TOWN OF SOUTHOLpaI Inspector oxtAq EOox-Town Hall Annex- 54375 Main Road - PO Box 1179 ^� wN of Southold, New York 11971-0959 o Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrn-southoldtownny.4ov- sea nd n-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTR AN INFORMATION (All Information Required) Date: 10 / 06 / Company Na e: Ryleigh Electrtic Inc. Electrician's Name: Michael Pistone License No.: 215-ME Elec. email: info@ryleighelectric.com Elec. Phone No: 631- 1-0462 ml request an email copy of Certificate f Compliance Elec. Address.: 247 Po 'on Rd. Ronkonkoma. NY 11779 JOB SITE INFORMATION ()Al formation Required) Name: New Horizon omes Inc. Address: 100 Dawn Dr Cross Street: Greenport Phone No.: 631-745-7128 Bldg.Permit#: 45620 em*(-newshorizonhomesinc@gmail.ca Tax Map District: ' 1000 Section: 35--\ B ck: 5 Lot: 11 BRIEF DESCRIPTION OF WORK, INCLUDE SQUAR 0" TAGE (Please Print Clearly): Residential basement being converted to Living S ce uare Footage: 1000 Circle All That Apply: Is job ready for inspection?: �/ YES NO ❑Rough Final Do you need a Temp Certificate?: ❑ YES NO Issued On %\,7 Temp Information: ( information required) Service Size❑1 Ph 3 Ph Size: A #Meters Old Met ❑New Service❑Fire Re nnect❑Flood Reconnect❑Service Reconnect❑Underground Overhead # Underground Latera 1 2 H Frame Pole Work done on Service? Y Additionallnfor ion: PAYMENT DUE WITH APPLICATION ECE � ME ILDING DEPARTMENT-Electrical Inspector OV $ ���� TOWN OF SOUTHOLD y ILDING DEPT. Town Hall Annex- 54375 Main Road - PO Box 1179 1,, N OF SOUTHOLD Southold, New York 11971-0959 �'IS- ��o�� Telephone (631) 765-1802 - FAX (631) 765-9502 'X' rogerr@,southoldtownny.gov — seand(@,southoldtownny.4ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: _ Company Name: GJS Electric, LLC Electrician's Name: Gary Salice License No.: 4839ME Elec. email:gary@nfay.com _Elec. Phone No: 631-298-4545 D 1 request an email copy of Certificate of Compliance Elec. Address.: 6615 Main Rd., Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: Address: LIU Cross Street: �, Phone No.: _ Cj �-I -pom Bldg.Permit#: � S( -An email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: J�Rough Ndv 2. -7 r Is job ready for inspection?: YE NO ❑ Final Do you need a Temp Certificate?: YES �0 Issued On Temp Information: (All information required) Service Size❑1 PhF-13 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 12 H Frame Pole Work done on Service? Y N Additional Information: ® E C E � VI ENT DUE WITH APPLICATION � NOV 0 9 2021s� l h � 7 '4t BUILDING DEPT. O TOWN OF SOUTHOLD �� ECEVVE Os�fILDING DEPARTMENT- Electrical'Inspector OV 0 8 2021 TOWN OF SOUTHOLD co N ILDING DEPT. Town Hall Annex-54375 Main Road - PO Box 1179 N OF SOUTHOLD Southold, New York 11971-0959 *4 �ap� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrc(&,southoldtownny.4ov - seand(,U�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: GJS Electric, LLC Electrician's Name: Gary Salice License No.: 4839ME Elec. email:gary@nfay.com -Elec. Phone No: 631-298-4545 [D I request an email copy of Certificate of Compliance Elec. Address.: 6615 Main Rd., Mattituck, NY 11952 JOB SITE INFORMATION (All information Required) op Name: 7�nkn L4 " Address. I('- � .o .J- Cross Street: W Phone No.: Bldg.Permit#: i4 C, ( a n email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage:. Circle All That Apply: 90✓ I�t _ Is job ready for inspection?: YE ❑ NO Rough I ❑ Final Do you need a Temp Certificate?: YES Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals1 2 H Frame Pole Work done on Service? M Y N Additional Information: D V( ENT DUE WITH APPLICATION NOV 0 9 2021s� h l 7 \ BUILDING DEPT. Q TOWN OF SOUTHOLD �� Q' PERMIT# Address:- Switches ddress:Switches I Outlets G F I's Surface Sconces H H's UC US Eri.d_;.eFans ._. . . ...,. _ .. H.W.. Exhaust Oven WD: ..;` .. .. ,_ Smokes DW .Mini :. CarbQn 'Micro. _ enerafor Combos . Cooktop . '.Tran fer' , :;4c AH Hood Service 'Amps Have Used Special:., S V M,.� . . . .. .. _.: _ . _ . . . .. . .. .. Comments: �� v�l :. i Town Hall Annex ' Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD August 13, 2020 John Ryan 90 Dawn Drive Greenport, New York 11944 Dear Mr. Ryan: RE: Suffolk County Tax Map Number 1000-35-5-11, 90 Dawn Drive, Greenport, New York, owned by John Ryan. Please be advised the above property is also known as 100 Dawn Drive, Greenport, New York. Best Regprds,/ Connie Bunch Southold Town Building Dept. SYMBOL LEGEND O MONUMENT FND FIRE HYDRANT ED GAS METER FE. FENCE O I.P. /I.B. FND (D MANHOLE ® WATER METER MAS. MASONRY ® I.P. /I.B. SET IM "A"-INLET pd GAS VALVE PLAT. PLATFORM t o0l SPOT ELEVATIONS '® "B"-INLET WATER VALVE W,W. WINDOW WELL ' j—" TRAFFIC SIGNAL POLE ® "E"-INLET TEST HOLE B/W BAY WINDOW CQj UTILITY POLE ® YARD INLET TREE C/E CELLAR ENTRANCE > GUY WIRE ® YARD INLET SHRUB 0/H OVERHANG UTILITY POLE W/LIGHT ® CABLE TV BOX 0 BOLLARD R/0 ROOF OVER )�( LIGHT POLE Z A/C UNIT AL WETLAND FLAG L.S.A. LANDSCAPED AREA SIGN (0 ELECTRIC METER CANT. CANTILEVER DX. DEPRESSED-CURB ,TI III t' ¢pi LANE'' WIGGINS f , I (50' WIDE) i L EDGE OF PAVEMENT - EDGE OF PAVEMENT•- i e --- ----�'� SLATE RET. N66°39WALL(12') 50"E 147.35_ �=•, y[ N W FND.FE y[rr m 3.7'f MON. WALL D, ;• ° 10.5' I ' s O A) c� -► I t.I I Q GO O -'4 Zv Q FM LOT 76 ASPHALT SLATE WAu( Ada " 011 I j TAX LOT It DRIVEWAY a F/S ` 9f6.3 � O I n c, TAX LOT 28.2 = -> ' ®Q�o�4.D`,.o:R/o 7 0.4- 24.7 38.1' I O '3• : GARAGE' - r � I� it ti .�'' --� _ �'- D I �;n CHAIN F lo,-,..- -' .1 'S79RY 11 r s p w LANK FEN. ,_ - -FRAME-RESIDENCE^ P)GA %< 'll FEN' 20,2''2.3'�. F�S12.D 42.8' 5.0' OI ® PA710 ,TE DECK 41.4' O (3fi• FEN 42.8L N► Ii AB I M . 0.44 ON � _ II ' O.r Try LATE WALL(12") O I FEN r.7/Q°,�,z,20pf T/T �� CAIN LINK FEN.4IEN' �/ 154.72' 0 NJ GATE -- - 33.7. I - — - - -- ,I g I :4 C x $0 1 FM LOT 75 2 g TAX LOT >2 z t :P z i Ii g s CHAIN LINK FEN. g z g f, FM LOT 74 %} TAX LOT 13 LOT AREA i 29,315.94 S.F. GRAPHIC SCALE 0.67 AC. j 30 0 15 30 { �! GUARANTEED TO: JOHN R. RYAN JR. (a ) sTEWARCOMPANY IN FEETLoANDEPOT.COM LLC. ' 1 inch = 30 ft. ISAOA/.ATIMA �E OF NEW 'SURVEY SCALICE LAND SURVEY OF PROPERTY r PES J. 2cq 0� LOT 75 AND 76 G� l� MAP OF s SURVEYING P.C.- CLEAVES POINT JJ Always On P o i n t SECTION NO. 3 n 99-io5 West Hoffman.Avenue, Lindenhurst, New York 11757 j; Email:MJScalice�a)mjslandsurvey.com Phone:631-957-240o Fax:63i-226-240o FILE DATE: 06/14/1966 MAP N0. 4650 !, 4 $� 0� SITUATE 4+ cF�s °•0508 ��� DR.:MC CREW.:AL SCALE: 1" = 30� SUFFOLK TAX MAP N0. GREENPORT, TOWN OF SOUTHOLDr F� LAND DATE SURVEYED:04/30/2019 JOB No,S19-0798 0100-035.00=05.00-011.000 SUFFOLK COUNTY, NEW YORK I' ^�(1)UNIDTHORIZEO ALTERATION OR ADDITION TO THIS SURVEY MNP BEARING A LICENSED LAND SURVVOR'S SEAL IS A VIOLATION OF SECTION 7208,SUB-DIVISION 2,OF NEW YORK STATE EDUCATION LAW.(2)ONLY BOUNDARY SURVEY NAPS WIM THE'SURV'YOWET EMBOSSED SEN.ARE GENUINE TRUE AND CDR TTECT COPIES OF THE SURVEYOR'S ORIGINAL WORK AND OPINION. 'L (3)CNAUTHOTIONS ON THIS BOUNDARY SURVEY NAP SIGNIFY THAT THE MAP'WAS PREPARED IN ACCORDANCE WITH'WE CURRENT EXLSTINO CODE OF PRACTICE FOR LAND SURVEYS ADOPTED BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS,INC.THE ALWAYS N OF"UMMED TO PERSONS.FOR D.IF THE BOUNDARY SURVEY MIP N PRFPMID,R) :.THE TITLE COMPANY,TO THE GOVERNMENTAL AGENCY,AND lb THE LENDING INSRMION LASTED ON THIS BOUNDARY SURVEY MAP.(4j TME CERTIFlCARONS HEREIN AAE NDT TRMSFIINBLE(S)THE LOGTION OF UNOERCRDUND IMPROVEMENTS OR ENCROACHMENTS ME NOT ALWAYS IDTOVM AND OFTEN MUST BE ESTIMATED.ff ANY UNDERGROUND IMPROVEMENTS OR ENCROACHMENTS EXIST OR ARE SHOWN,THE IMPROVEMENTS OR ENCROACHMENTS ME NOT COVERED BY THIS SURVEY.(S)THE OFFSET(OR DIMENSIONS)SHOWN HEREON TROM THE STRUCTURES TO.THE PROPERTY UNES ARF.FOR A SPECIFIC PURPOSE AN USE AND THEREFORE ME NOT INTENDED/ GUISE THE ERECTIONOFE OF FENCER,NOT SHO WALLS,NOT GU PATIOS PLANTING MFRS,AODTTIONS 10 BUILDINGS,AND ANY OTHER TYPE OF CONSTRUCTION:(7)PROPERTY CORNER MONUMENTS WERE NOT SET AS PRAT OF THIS SURVEY.(B)THIS SURVEY WAS PERFORMED WITH A SPECTRA FOCUS 3O ROBOTIC TOTAL STATION. (9).THE EXISTENCE OF RIGHTS OF WAY AND/OR EASEMENTS OF RECORD IF ANY,NOT SHOWN ME NOT CUMANIEED. i 1zGenerated by REScheck-Web Software Compliance Certificate Project RYAN RESIDENCE Energy Code: 2018 IECC Location: Greenport, New York DEC, 2 8 2020 i. Construction Type: Single-family Project Type: Alteration Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 100 DAWN DRIVE JOHN RYAN TODD O'CONNELL GREENPORT, NEW YORK 11944 100 DAWN DRIVE TOC ARCHITECTS GREENPORT, NEW YORK 11944 1200 VETERANS MEMORIAL HWY HAUPPAUGE, NEW YORK 11788 TODD@TOCARCHITECTS.COM Compliance-,Passes using prescriptive requirerTients for alteration projects, Envelope Assemblies Gross Area Cavity Cont. Assembly .or R-Value R-Value U-Factor UA Perimeter Basement:Wood Frame 1,140 15.0 0.0 0.056 64 Wall height:7.5' Depth below grade: 6.0' Insulation depth: 7.5' Compliance Statement. The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version, PEScheck- eb and to comply ith the mandatory requireme -,t - d��in'ethe REScheck Inspection7ec t. 'y 74 Name-Title Sifgnatur 7/1 bA -Date Project Title: RYAN RESIDENCE Report date: 12/10/20 Data filename: Page 1 of 1 rod CLIMATIC AND CEOCRAi�HIG DESIGN CRITERIA TABLE R301.2(I) INTERNATIONAL RE5IDENTIAL GORE SUBJECT TO DAMAGE 11 N.ICI WIND DESIGN FROM 7 o f�D Ca'C C�M N I ICI ARCI11'I P. C, If 777� FOROUND SPEED d TOPOG SPECIAL WIND SEISMIC (MPH) RAPHIG WIND BORN DE51ON WEATHERING FROST LINE TERMITE WINTER ICE FLOOD AIR MEAN AIIA EFFECTSF EGION DEBRIS CATEGORY DEPTH p DESIGN BARRIERHAZARDS 4 FREEZING ANNUALZONE m p TEMP Q REQUIF ED h INDEX TEMP � �Q' {� �f1200 Veterans Memorial.Highway 120 BOF 5 FT OM D TO FEMA130w1t NO NO I MILE B SE BFG HEAVY J5 Y€� EI�Q� 1500 OR 55.4 Suite Hauppauge,NY11788 FROM MAP_ LESS COAS PANEL# p(6 ,) 0_6666 W I G G I N S LANE F(631)650-6667 MANUEL J DE5I6N CRITERIA " _ C(516)658-0325_ DESIGN TEMPERATURE HIGH TEMPERATURE E I I WINTER E- rN !FACTOR TITUDE CORRECTION INDOOR DESIGN COOLING DIFFERENCE , •. y , x "�^'ro ELEVATION LATITUDE= HEATING TEMPERATURE ------ ------ --- ------ ------ -_-__- SUMMER HUMIDI7`f -- WIND WIND COINCIDENT DAILY RANGE WINTER HUMIDITY COOLING I VELOCITY VELOCITY WET BULB TEMPERATURE DIFFERENCE HEATING COOLING (^ / 147 -35 I TO THE BEST OF MY KNOWLEDGE, BELIEF AND 9150E �� PROFE5510NAL JUDGEMENT, THESE PLANS 3 COMPLIANCE N66 _ '�'�'�AND/OR 5PECIFIGATIONS ARE IN IZ'y 170 WITH THE FOLLOWING: "�'� 2020 RESIDENTIAL CODE OF NEW YORK STATE — I PUBLICATION NOVEMBER 201`1t 7 L N I I 2020 RESIDENTIAL CODE OF NEW r YORK 5TATE N I to CHAPTERS 12-25 FOR MECHANICAL SYSTEMS � _ . � IS o N O CODE OF NEW YORK STATE N 2020 RESIDENTIAL O UEL 4 GAS SYSTEMS z # CHAPTERS 24 FOR F 2020 RESIDENTIAL CODE OF NEW YORK STATE o ASPHALT -� o I CHAPTERS 25-55 FOR PLUMBING 5Y5TEM5 O SLATE WALK - DRIVEWAY = ° z 2020 RE51DF-NTIAL CODE OF NEW YORK STATE — I 1. CHAPTERS 54-42 FOR ELECTRICAL 5Y5TEM5 j 'L 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE EGRESS I m F�,u AS ADOPTED WITH THE 2018 IEGC z ~ I U 00 WINDOW THE PROJECT COMPLIANCE METHOD CHOSEN 15 TOTAL S = ww UA-ALTERNATIVE AND A RES0 GHECK HAS BEEN SUBMITTED I I `7� °o OWQ v o J/ �o a WITH THESE DRAWINGS. I � W WNWO�pQzm° lU pzFx�Ow N v aw_ �zp v I mo;< z a iz v (p� J ~JjQJ1Q(�p R} 20. <t�WGll~�OFQ�e� � I Q��� W a�,�p PROP. FINISHEDLL�oaow ZON I NO INFORMATION BASEMENT �' - a o ® o TONN OF SOUTHOLD N O LOT 5): 011.000 (1 ,300 SQ. FT.) SECTION: 035.00 BLOCK: 05.0 ( SHED zU�OO� �0f ZONE: R-40 REQUIRED EXI5TINO ?0.2 4I '4 WW�QWa� '"HO LOT AREA 40,000 SOFT. 14,323 50-FT. 1 I / �a Q moo o° Ll FRONTAGE 150 FT. 147.35 FT. 42.8?&I J \ I I FRONT YARD 50 FT. 471 FT. M V v V N N � � RONT 1!ARD ✓O FT. 38.1 FT. F I REAR YARD 50 FT. 20.4'1 FT. SIDE YARD (MIN) 15 FT. 42.86 FT. ATE PATIO DECK REL GATED AIC UNITS. i I BUILDING HEIGHT 55 FT N/A F SL LOT COVERAGE 20 % CD Q Q Z 0 ' CD I to F� v Z 0 I z � Q I _ p— _ ...... _ v o CA z U 1 I W cO z — l9 7 lL H � l� l� z 154 . S70022'20"WN W 0OL L 0 I 0 U N x 0 Io 0 Q00000 I p n i to N d N () N Q I PLOT ipLAN a SCALE I"= 10'-0" z Ldd- ua � b- CD LU>= 0 OL Q � OLu �n o UA OL O No 0 v O M Jurl 1 1 2n21 Q � � tii z A.3 p110LDC �[:! ! AFCHITCHITECT p.C, 4 TODD O'CO3N A LL,AGA FLOOR JOISTS 1200Veterans Memorial Highway RELOCATED A/C UNITS. HVAC Suite 120 v ! CLOSET 2" SHEET ROOK Hauppauge,NY 1178E 650-6666 LINE OF GHANOE m CEILING F�631)65Q--6667 IN F.J. DIRECTION I _ ( ) — — — I C(516)658-0325 I I € 21,X4" AGQ STUD WALLWr ..� .+-. +s ,y� I I I EXISTING FOUNDATION WALL WITH tip © 16" O E ? V POURED CONCRETE FOOTING (V.I.FJ.IL I "X5" F.J. ® Ib" O.G. € w O PERIMETER PARTITION WALL-2" X 4" 0 HATER �j165- z I 7'-b" BELOW [Q = �9 AGQ WOOD STUDS a 16" O.C. OO FILTER O X N ® PROVIDE R-15 KRAFT-FACED BATT Y2° SHEET ROCK 0 41-411— I iv INSULATION AND 1/2 INTERIOR GYP. `;` RELOCATED ® w (3)2"X1_0" LVL ' BD. (SEE SPECIFICATION AND NOTES) IGAL INTERIOR 4 ' LAUNDRY UNFINISHED m �� -7= L CONSTRUCTION: tL f ; R-15 BATTEQUIPMENT BASEMENT 11 2 1 4 2" " STUD WALL.0-16" NSULATION GL6. HT. ;�1- [A - - O.G. 1 10r XX Ys" 6YP5UM BOARD i ! LCFINISHit E, REG ROOM 7'-5" GL6. HT. j EXISTINS SLP�BFOUNDATIONNALL Q 2MEMBRANE BETW EN 8302.7. UNDER STAIR PROTECTION. O SUMP ELEG. SHEET ROCK AND INSULATION ENCL05ED AGGE551BLE SPACE UNDER PUMP PANEL "X8" I_BEAMSTAIRS SHALL HAVE WALLS, UNDER (F T 2"X4" ABOVE) STAIRS SURFACE AND ANY SOFFITS i FLOOR FINISH TO BE SELECTED PROTECTED ON THE ENCLOSED SIDEWITH �" 6YP5UM BOARD MAINTAIN 6'-5" CLEARANCE OVER . 2"X4"STAIR PER CODE. (NOTE: 6'-4" w �j PROJECTIONS INTO REQUIRED 6'-5" V > AGQ PLATEHEIGHT PERMITTED PER CODE) Q 0 M1U2"X5" F.J. ® 1'-0" O.G. X�T-5" GL6. HT. z z -i _ X N J" GYPSUM BOARD� ON ALL BASEMENT LIQ d0 F CEILINGS A5 PER ro o N SECTION 8302.13PROVIDE "B" wLABEL DOOR vRELOCATEo 'z EX15TINO X OL TANK e /+se ,� ,� zo��U�E G CWI35 PA 5 NNEW EGRESS ����Qo � tuWINDOWv 0z kn WINDOW MAX 44" WwMg�oaoABOVE FINISHED FLOORNALL DETA I LOIL OIL �R510 EMERGENCY ESCAPE AND V5TAIR5 AND RAILINC75 u� 12" WIDE PERMANENTFURNRESCUE OPENINGS: MUST CONFORM TO COMPLYING LADDER ASSCALE: 5/4" = 1'-O"AT LEAST ONE EGRE55 WINDOW IN PROVIDE STAIRWAY LIGHTING AS PER STATE CODE R311 AND REQUIRED UP TO GRADE o �5QNEACH 5LEEPIN6 ROOM 15 TO BE SECTION 8303."( INTERIOR STAIRWAY 8312. 36" MIN. HEIGHT, 12'-5" WITH MAXIMUM b" 61a �' ingPROVIDED FOR EMEROENGY ESCAPE. ILLUMINATION: INTERIOR STAIRWAYS 35" MAX. HEIGHT ENCROACHMENT INTO m o oMIN. 5.7 SQ.FT. MIN. H=24 , MIN. W=20 , Q Q_� 'I11 ART FICIAL LI6HTD50URGE TOREQUIRED DIMENSIONS MAX 44 A.F.F. ILLUMINATE THE LANDIN65 AND WELLCRAFT WELLTREADS. THE LIGHT SOURCE SHALL BE PROVIDE 5/8" TYPE X" 2060 SINGLE UNIT �'v oR315 / AJ403 / AJ504 / AJ604 SMOKE AND GO CAPABLE OF ILLUMINATING TREADS 6YP5UM WALL BOARD. )=6RE55 WINDOW WELL ,nALARMS AND LANDIN65 TO LEVELS OF NOT 10��ouCARBON MONOXIDE ALARMS TO BE PROVIDED LESS THAN I FOOT-CANDLE 01 LUX) A5ON EACH LEVEL WITH 5LEEPIN6 ROOMS OR FUEL MEASURED AT THE ENTER OP TREADSE ALARMS TO BE AND LANDIN65. THERE 5HA!-L BEA QQ* Q Q BURNING EQUIPMENT, SMOK w w��WALL SWITCH AT EACH FLOOR LEVEL 8303.1 - VENT-EXCEPTION 2PROVIDED IN EACH 5LEEPIN6 ROOM, OUTSIDE TO CONTROL THE LIGHT O URGE NOTE= PROVIDE MINIMUM OF .55 AIR NOTE: COORDINATE ALL FIN15H AREA TO VENTILATE: EACH 5LEEPIN6 ROOM AND ON ALL FLOORS CHANGE PER HOUR IN FINISHED MATERIALS WITH CLIENT PRIOR FINISHED BASEMENT- 456 5Q.F7. a[WHERE THE STAIRWAY HA5 SIX OR BASEMENT d A MINIMUM OF 6 FEET TO CONSTRUCTION- FLOOR, 800 SQ.FT. X 7'-5" (1.42') GLC.HT. = 5,936 GUBIG FT. V V V N NMORE RISERS CANDLES OF ILLUMINATION a 30" GEILIN6, WALLS, ETC. h:VE THE FLOOR AS PER 8303 OF 5,x36 GUBIG FT. X 0.35 (AIR GH:ANGE/ HR) = 2,077.6 GUBIG FT./ HR. THE RGNYS 2077.6 GUBIG FTJ HR / 60 MI1�li1HR. = 34.63 GUBIG FT./ MIN- REQUIRED NOTE: HARDWIRED SMOKE PROVIDE 40 CFM FAN NOTE: ALL A55UMED EXISTING DETECTORS TO BE PROVIDED IN STRUCTURE SHALL BE VERIFIED IN ALL BEDROOMS AS PER CODE. FIELD. ALL DISCREPANCIES SHOULD 8303.1 - LIGHT-EXCEPTION 2 BE BROUGHT TO THE ARCHITECTS A MIN. OF 6 FOOT CANDLES(65ATTENTION IMMEDIATELY. NOTE: INTERIOR WALLS TO BE Ix) OVER THE AREATYPICAL INTERIOR WALL COVERWCONSTRUCTION: OF A ROOM AT A HEIGHT OF 30INCHES ABOVE THE FLOOR NOTE: CONDITIONS DRAWN AND 2x4 STUD WALL a I6 O.G. W ZNOTED AS EXISTING ARE TO BE Y2" 6YP5UM BOARD FINISH D WCONFIRMED AT START OF I (fc) = I(Im) / SCL.ft. Z XCONSTRUCTION. ARCHITECT 15 TOB I (Ix) = I NO X 10."16 Q XNOTIFIED IMMEDIATELY OF ANY NOTE: ALL PERIMETER Lux = I lumen / sq,.m. o „ I Im = I (Ix) x area m— (— PARTITION WALL-2 x 4 AGQBOTTOM PLATE, 2" X 4" WOOD I Im = 0.001496 WATTS � vI led bulb = 800 lumens (5-12N)STUDS ® Ib O.G. PROVIDE R-15 w 0 Z Z z NOTE: UPGRADE EXISTING E Z NCONDITIONS TO MATCH KRAFT-PAGED BATT INSULATION FINISHED BASEMENT /"//GONDITIONPSL INDICATED ON AND I/2" INTERIOR GYP. BD. 500 SQANS. .FT. x 0.093 = 74.4 Q Ju 0 0 Q W llQQIISQUARE METERS(SHAD I� ll 51�lTII�lLumens = 74.4(1x) X 42.4 sc�.m. BUILT INI"1 J— LADDE„ Q QN5GALE I/4 = I -O PROVIDE AT LEAST 4 led bulbs Q u� ry no ly �6„ MIEXIST. 2"X5" F.J. a I6" O.G. V.I.F.IIII l X8 1 —SEAMSLAT 2"X411 AEOVE ' LH ( o 0 0 0 0 0 (� vIt 51 UA �S=/EXISTING FOUNDATIONWALL WITH FOURED2, STONE OONGRETE FOOTING N.I .F.). o o ` AiCFILL jREQ . ROOM FERIMETER PARTITIONI !! III I- — GLC. HT. WALL-2 x 4 AOGQ WOODSTUDS @ 1 O.G. FROVID �— R-15 KRAFT—FACED BATT *MCTED TO/FOUNDA to � ua INA SYSTEM/ /NSULATION AND 1/2 " ,Fcn `� O 1-1-1r %INTERIOR C1'i=. �3D. (SF— n_AQ n.s0 / �'' / / D- Si�EGIFI OATION AND O z NOTES) O Q� � m VI Q2ORO55 SEOTION J F-RF-55 HIN7ON DETAIL � SCALE I/4"= I'-OSCALE I/4"= I'-b" z ■ O Q 0 Q GENERAL CONDITIONS UNLESS OTHERWISE NOTED, GENERAL FIRE BLOCKING 2020 NYSEGG -AIR LEAKAGE: 2020 EGG OF NEW YORK STATE: CONDITIONS OF THE CONTRACT FORFIRE BLOCKING SHALL BE PROVIDED, INSULATION -JOINTS, PENETRATIONS, AND ALL R401.5: PERMANENT CERTIFICATE - SHALL BE COMPLETED BY THE MINIMUM DE51GN DEAD LOADS A5 PER ASCE -I CONSTRUCTION, AIA DOCUMENT-201 AS PER SECTION R502.15 OF THE ALL EXTERIOR WALLS AND ROOFS OTHER SUCH OPENINGS IN THE BUILDER OR RE515TF-RED DESIGN PROFESSIONAL AND POSTED IN 7-I6 - CHAPTER 3 TABLE 03.1 c�•c 4/87 SHALL APPLY. THE CONTRACTOR RESIDENTIAL CODE OF NEW YORK SHALL BE INSULATED WITH FOIL BUILDINGS ENVELOPE THAT ARE THE UTILITY ROOM OR OTHER APPROVED LOCATION IN51DE THE COMPONENT LOAD SHALL OBTAIN CERTIFICATE OF ( sf) STATE, TO GUT OFF ALL CONGEALED FACED FIBERGLASS BATT INSULATION SOURCES OF AIR LEAKAGE MUST BE BUILDING. OCCUPANCY. SUBSTITUTIONS SHOULDVERTICAL C u DRAFT OPENINGS (BOTH BY JOHN MANVILLE OR APPROVED SEALED. G E I L I N G 5 TODD n+, ry rye r r NOT BE MADE WITHOUT WRITTEN A f. c H a T r. c T P. C. AND HORIZONTAL). EQUAL, FOIL TO BE PLACED TOWARD -RECESSED LIGHTS MUST BE TYPE IG 8402.2.4: ATTIC OR CRAWL SPACE ACCESS - SHALL BE i AUTHORIZATION BY THE ARCHITECT. PROVIDE FIRE BLOCKING IN WARM SIDE. PROVIDE 11/2" RIGID RATED AND INSTALLED WITH NO WEATHER-STRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO ACOUSTICAL FIBER BOARD 1.0 THE PREMISES SHALL BE KEPT CONGEALED SPACES OF STUD WALLS FOAM INSULATION ON ALL EXTERIOR PENETRATIONS, OR TYPE IG OR NON-IC THE INSULATION ON THE SURROUNDING 5URFACE5. GYPSUM BOARD (per � INCH thickness) 0.55 REASONABLY GLEAN AT ALL TIMES. AND PARTITIONS, INCLUDING FURRED FOUNDATION WALLS FROM FOOTING RATED INSTALLED INSIDE AN (1/2 INGHE5) (2.2) TCDD O'CONNELL,AIIA AT THE COMPLETION OF WORK, THE SPACES AT THE CEILING AND FLOOR TO 6"BELOW FINISHED GRADE UNLESS APPROPRIATE AIR-TIGHT ASSEMBLY R402.4: AIR LEAKAGE - BUILDING THERMAL ENVELOPE SHALL BE (5/5 INCHES) (2.75) 1200 Veterans Memorial Highway CONTRACTOR SHALL REMOVE ALL LEVELS. CONGEALED HORIZONTAL OTHERWISE SPECIFIED. CARE SHOULD WITH 0.5" CLEARANCE FROM CONSTRUCTED TO LIMIT AIR LEAKAGE TO < 5 AIR CHANGES PER MECHANICAL DUCT ALLOWANCE 4.0 Suite 120 WASTE MATERIALS, TOOLS, RUBBISH, FURRED SPACES SHALL ALSO BE FIRE BE TAKEN NOT TO DAMAGE COMBUSTIBLE MATERIALS AND 5" HOUR. Hauppauge,NY 117f38 ETC., GLEAN GLASS AND LEAVE WORK BLOCKED AT INTERVALS NOT FOUNDATION WATERPROOFING. CLEARANCE FROM INSULATION SUSPENDED STEEL CHANNEL SYSTEM 2.0 BROOM GLEAN UNLESS OTHERWISE WOOD FURRING SUSPENSION SYSTEM 2.5 P(631)650-6666 SPECIFIED. THE CONTRACTOR SHALL EXCEEDING 10 FEET. 8402.4.1.1: INSTALLATION - THE COMPONENTS OF THE BUILDING F(631)650-6667 GLASS WINDOWS AND DOORS VAPOR RETARDER: THERMAL ENVELOPE SHALL BE INSTALLED IN ACCORDANCE WITH C(516)65€3.0325 CARRY WORKMAN'S COMPENSATION PLUMBING TO BE INSTALLED AS PER SECTION -REQUIRED ON THE WARM-IN-WINTER THE CRITERIA LISTED IN TABLE 402.4.1.1. WHERE REQUIRED BY G O V E R 1 N G 5, ROOF, AND W A L L AND GENERAL LIABILITY INSURANCE. CONTRACTOR SHALL INSTALL WATER 8308 OF THE RE51DF-NTIAL CODE OF SIDE OF ALL NON-VENTED FRAMED CODE OFFICIAL, AN APPROVED THIRD PARTY SHALL INSPECT ALL ALL SHALL COMPLY WITH STATE ANDASPHALT SHINGLES 2.0 SUPPLY AND SANITARY 5Y5TEM AS NYS. ALL GLA55 IS TO BE INSULATED CEILINGS, WALLS, AND FLOORS. COMPONENTS AND VERIFY COMPLIANCE. ' LOCAL CODES AND ORDINANGE5. THE INDICATED. PROVIDE HOT AND GOLD LOW-E UNLESS OTHERWISE SPECIFIED. GYPSUM 5HEATHING, 1/2-In. 2.0 CONTRACTOR SHOULD FULLY SHUT-OFF VALVES AT ALL FIXTURES. GLASS SUBCONTRACTOR SHALL NOT MATERIALS IDENTIFICATION: 8402.4.1.2: TESTING - BUILDING OR DWELLING UNIT SHALL BE INSULATION, ROOF BOARDS (per inch thickness) GUARANTEE HIS WORK AND THE WORK ALL WATER PIPING TO HAVE INSTALL GLA55 UNTIL PROPER -MATERIALS AND EQUIPMENT MUST BE TESTED AND VERIFIED AS HAVING < 5 ACH50 IN CZ4A, 5, A&A. FIBERBOARD OF HIS SUBCONTRACTORS FOR A GLEANOUTS AT ALL CHANGES OF CLEARANCES ARE PROVIDED. ALL INSTALLED IN ACCORDANCE WITH THE TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY. PERLITE I.5y. PERIOD OF ONE YEAR AFTERDIRECTION AND AT BASE OF SLIDING GLASS DOORS, SKYLIGHTS MANUFACTURER'S INSTALLATION POLYSTYRENE FOAM COMPLETION OF THE PROJECT UNLESS VERTICAL WASTES. USE 4" CAST IRON AND/OR WINDOWS AS REQUIRED BY INSTRUCTIONS. 8402.4.4: COMBUSTION CLOSETS - ROOMS CONT,; CLIMATIC AND CEOCRAPHIC DESIGN CRITERIA TABLE 8501.20) INTERNATIONAL RESIDENTIAL CODE K 1� s WIND DESIGN SUBJECT TO DAMAGE FROM GROUND SPEED TOPOG SPECIAL WIND SEISMIC 10 U G (,)'r 0 N N(!.:. 5NOW (MPH) RAPHIG WIND BORN DESIGN WEATHERING FROST LINE TERMITE CI WINTER ICE FLOOD AIR MEAN :A r c Ii i e c LOAD EFFECTS REGION DEBRIS CATEGORY a DEPTH 12 DE51ON BARRIER HAZARDS 9 FREEZING ANNUAL k ZONE m f TEMP Q REQUIRED b INDEX I TEMP J 30 130w1t NO NO I MILE B BOF 5 FT MOD TO FEMA — c ,' TODD OAC r4ELLr AIIA SEVERE BF6 HEAVY 1`z Y� �O 1500 OR55.4 FROM MAP LESS 1200Veterails Memorial Highway COAST PAS # Suite 120 Hauppauge,NY 11788 MANUEL J DESIGN CRITERIA n W I G G I N S L A N E P(531)650-6666 WINTER SUMMER ALTITUDE CORRECTION INDOOR DESIGN DESIGN TEMPERATURE HIGH TEMPERATURE I F(631)6$0-6667 ELEVATION LATITUDE HEATING COOLING FACTOR TEMPERATURE COOLING DIFFERENCE � C($16)6$$-032$ COOLING WIND WIND COINCIDENT DAILY RANGE WINTER HUMIDITY SUMMER HUMIDITY TEMPERATURE VELOCITY VELOCITY WET BULB DIFFERENCE HEATING COOLING 147 -351 ................... - TO THE BEST OF MY KNOWLEDGE, BELIEF AND I _ ..�� PROFESSIONAL JUDGEMENT, THESE PLANS39'5011 E -� ....� AND/OR SPECIFICATIONS ARE IN COMPLIANCE 60391 a WITH THE FOLLOWING: I N66 _ _ ................ ----- 2020 RESIDENTIAL CODE OF NEW YORK STATE _ ------.- �� I PUBLICATION NOVEMBER 2011 2020 RESIDENTIAL CODE OF NEW YORK STATE ' I CHAPTERS 12-23 FOR MECHANICAL SYSTEMStF IV v I ►V I m 2020 RESIDENTIAL CODE OF NEW YORK STATE p I N CHAPTERS 24 FOR FUEL 4 GAS SYSTEMS O 2020 RESIDENTIAL CODE OF NEW YORK STATE -P Z 0 CHAPTERS 25-33 FOR PLUMBING SYSTEMS oASPHALT _ c5I 2020 RESIDENTIAL CODE OF NEW YORK STATE I SLATE WALK CHAPTERS 34-42 FOR ELECTRICAL. SYSTEMS - DRIVEWAY = o � 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE I Z AS ADOPTED WITH THE 2018 IECG I M Jin V 0. THE PROJECT COMPLIANCE METHOD CHOSEN 15 TOTAL p o o UA-ALTERNATIVE AND A RE5GHECK HAS BEEN SUBMITTED IN p w v WITH THESE DRAWINGS. D El El F zo, a I' . EGRESS �3 �°p�° = o 20.3WINDOW ZONING INFORMATION PROP. FINISFED �N,� o o x TOM OF SOUTHOLD � i I ��- BASEMENT � W ��NY�Q��� < a_ SECTION: 035.00 BLOCK: 05.00 LOT(5): 011.000 SHED (11300SQ. F7.) ZONE: 8-40 REQUIRED EXISTING LOT AREA 40,000 5G.FT. 14,323 50.FT. 20 2 x o w 3 FRONTAGE 150 FT. 147.35 FT. / '� p v �Q�� v ' InopoQ Q III FRONT YARD 50 FT. 47.7 FT. 42.al'J I FRONT YARD 50 FT. 38.1 FT. I x XY u REAR YARD 50 FT. 20.47 FT. 51 DE YARD (MIN) 15 FT. 42.86 FT. I BUILDING HEIGHT 35 FT N/A SLATE PATIO DECK LOT COVERAGE 20 % 1 15 % C-0 F C) I O cn p � O I z w 0 _ z O v I I LU p �. c 154.72' z z z S702220W � z00f ELECTRICAL LU INSPECTION (REQUIRED 1- °o � w IN° APPROVEDI 0 " 0 (3 " AS NOTED I o o � I N f\V N N ry < DATE: c\v N N D I � FEE: 3, � BY; w � d) NOTIFY BUILDING DEPARTMENT AT # PLOTI I 765-1802 8 AM TO 4 PM FOR THE I WW> PLAN FOLLOWING INSPECTIONS: Ix 1. FOUNDATION - TWO REQUIRED SCALE I"= 10'-O" FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING Blower door Z 3. INSULATION 4. FINAL - CONSTRI;C T ICzN MUST and ductwork l BE COMPLETE F0;- c.0. testing required. ALL CONSTRUCTION SMALL MEET THE lu REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR < _ DESIGN OR CONSTRUCTION ERRORS. Ifl LU COMPLY WITH ALL CODES OF Z NEW YORK STATE & TOWN CODES _ tu 1 AS REQUIRED AND CONDITIONS OF Z o J----I OL -S9�11 tD-T 7: . M IG BOARD Zaf "' -F9WRUS T EES 0 OCCUPANCY OR 0 USE IS UNLAWFUL o 0 WITHOUT CERTIFICATE o OF OCCUPANCY i N Q i z to J Q 0 D � D 1 A.3 ". �- mrt jr, ,�; ci��NI11 !.. t� i, C i Y. C. TOO O'C NIVElL AMA 6-� 01 FLOOR JOISTS 120OVeteraris Mee zorial Highway HVAC OC - CLOSET 2" SHEET ROCK Hauppauge,NY 11788 m CEILING , P(631)650-6666 � LINE OF CHANGE IN F.J. DIRECTION F(631)650-6667 — — — C(516)655-0325 W� 22'-5" 2"X4" AGQ STUD WALL +s ry > V EXI5TING FOUNDATION WALL WITH a'+rrr Q O J O POURED CONCRETE FOOTING LU _ = PERIMETER PARTITION WALL-2" X 4" OO WATEB 2"X5" F.J. ® I6" O.G. M ' ACO WOOD STUDS a I6 O.G. „ O FILTER O '�'-6" BELOW X - PROVIDE R-15 KRAFT-FACED BATT Y2 SHEET ROCK (- N ® INSULATION AND 1/2" INTERIOR GYP. RELOCATED ® w tlJ ~ (3)2"X10" LVL BD. (SEE SPECIFICATION AND NOTES) LAUNDRY UNE I N I SHED m > TYPICAL INTERIOR = X O WALL CONSTRUCTION: R-I5 BATT EQUIPMENT BASEMENT u� dl� tu 2"x4" STUD WALL a Ib" '1'-b" GL6. HT. = -1 = p C I INSULATION X = X y2" GYPSUM BOARD tc tc cV cV FINISH O X REG. ROOM 7'-5" CLO. HT. n® EXISTING SLAB FOUNDATION WALL u I MEMBRANE BETWEEN 8302.-. UNDER STAIR PROTECTION.— 5UMP ELEC. ENCLOSED ACCESSIBLE SPACE UNDER O PUMP PANEL _ — _ _ _ 6"xs" I_BEAM _ SHEET ROCK AND INSULATION STAIRS SHALL HAVE WALL5, UNDER (FLAT 2"X4" ABOVE) - in STAIRS SURFACE AND ANY SOFFITS FLOOR FINISH TO BE SELECTED m PROTECTED ON THE ENCLOSED SIDE - m WITH �" GYPSUM BOARD I I ry N MAINTAIN V-5" CLEARANCE OVER to Di 7'-5" Ui 2" " # X4 Z w STAIR PER CODE. (NOTE: 6'-4" I- PRI PERMITTED PER III ' 0 7 p O AGQ PLATE v HEI&HTODE) WINDOW MAX 44" - X10 to < ABOVE FINISHED FLOOR =_ w 4 21 F.J. ® I'-O" O.G. ® p 12" WIDE PERMANENT ! 7'-5" GLC. HT. ® X " GYPSUM BOARD V Z COMPLYING LADDER AS 3 QQ XIN ON ALL BASEMENT LIQ REQUIRED UP TO GRADE a - � F- CEILIN55 AS PER X u w o WITH MAXIMUM b" NEW EGRESS D X X � Q m O '►* u w J SECTION 8302.13 v Q 'z ENCROACHMENT INTO WINDOW � N tL SLAB w O 0 0 It- REQUIRED DIMENSIONS !~ I RELOCATE 4 m O-1 EXI5TIN6 is wNoJ� o } �c0 � OIL TANK ID e c. +6a -� ~ LU��N � PA 5HQZu � NELLCRAFT 2060 5 NGLE UNI N z 0 wu -o O W EGRESS WINDOW WELL z Jv� I,�I A I I OIL OIL WALL DETAIL °4 ~Q�zZ�o ~ Qv RNLI OJIY 0 8310 EMERGENCY ESCAPE AND VSTAIRS AND RAILINGS in HWH FURN SCALE: 3/4" = I'-O" <0 j> �09 �°m RESCUE OPENINGS: MUST CONFORM TO 1 0�tu m in AT LEAST ONE EORE55 WINDOW IN PROVIDE STAIRWAY LIGHTING A5 PER STATE CODE 8311 AND u EACH SLEEPING ROOM IS TO BE SECTION 8303.7 INTERIOR STAIRWAY R512. 56" MIN. HEIGHT, 12'-5" o z 19 PROVIDED FOR EMERGENCY ESCAPE. ILLUMINATION: INTERIOR STAIRWAYS 35" MAX. HEIGHT A•3 N u w p o z MIN. 5.'1 SQ.FT. MIN. H=24", MIN. W=20 , t w- SHALL BE PROVIDED WITH AN u$m m to�► MAX 44" A.F.F. ARTIFICIAL LI5HT SOURCE TO 0 a 5" �������' � ILLUMINATE THE LANDINGS AND 8303.1 - VENT-EXGEPTON 2 N°a °w v TREADS. THE LIGHT SOURCE SHALL BE s AREA TO VENTILATE: r-N°w q m -F o }- PROVIDE /8 TYPE X �pDov< �uoz Lp 8313 / AJ405 / AJ504 / AJ&04 SMOKE AND GO CAPABLE OF ILLUMINATING TREADS GYPSUM WALL BOARD. FINISHED BASEMENT- 456 5Q.FT. z�'- �' ALARMS AND LANDINGS TO LEVELS OF NOT 500 SQ.FT. X '7'-5" (1.42') GL6. HT. = 5,936 CUBIC FT. _O m°�N�To- 0 Z CARBON MONOXIDE ALARMS TO BE PROVIDED LESS THAN ( FOOT-CANDLE (I I LUX) A5 5,936 GUBIG FT. X 0.3'.5(AIR CHANGE/ HR.) = 2,077.6 GUBIG FT./ HR. �� ����z��� � ON EACH LEVEL WITH SLEEPING ROOMS OR FUEL MEASURED AT THE EATER OF TREADS 2077.6 CUBIC FT./ HR /60 MIN/HR. = 34.63 CUBIC FT✓ MIN- REQUIRED w w w d w (K BURNING EQUIPMENT, SMOKE ALARMS TO BE AND LANDINGS. THERE SHALL BE A PROVIDE 40 CFM FAN Q d m o o o S D PROVIDED IN EACH SLEEPING ROOM, OUTSIDE WALL SWITCH AT EACH FLOOR LEVEL NOTE: PROVIDE MINIMUM OF .55 AIRp EACH SLEEPING ROOM AND ON ALL FLOORS TO CONTROL THE LSOURCE CHANGE PER HOUR IN FINISHED N TE IGHT COORDINATE ALL FINISH WHERE BASEMENT d A MINIMUM OF 6 FEET THE 5TAIRhAY HAS SIX OR MATERIALS WITH CLIENT PRIOR v v N N TO CONSTRUCTION- FLOOR, 8303.1 - LIGHT-EXCEPTION 2 MORE RISERS CANDLES OF ILLUMINATION a 50" CEILING, WALL5, ETC. VE THE FLOOR AS PER R505 OF A MIN. OF 6 FOOT G?NDLES (65 THE RGNYS Ix) OVER THE AREA NOTE: HARDWIRED SMOKE OF A ROOM AT A HE15HT OF 30 DETECTOR5 TO BE PROVIDED IN INCHES ABOVE THE FLOOR NOTE: ALL ASSUMED EXISTING PER CODE. STRUCTURE SHALL BE VERIFIED IN ALL BEDROOMS A5 PI (fc) = I(Im) / sq,.ft. FIELD. ALL DISCREPANCIES SHOULD I (Ix) = I (fc) X 10.76 BE BROUGHT TO THE ARCHITECTS ATTENTION IMMEDIATELY. NOTE: INTERIOR WALLS TO BE Lux = I lumen / sq,.m. ♦- TYPICAL INTERIOR WALL I Im = I (Ix) x areaz L COVER 11.1 CONSTRUCTION: I Im = 0.001496 WATT5 NOTE: CONDITIONS DRAWN AND 2"x4" STUD WALL ® Ib" D.G. I led bulb = 500 lumens (5-12w) Z v O NOTED AS EXISTING ARE TO BE Y2" GYPSUM BOARD FINISH !U 13 CONFIRMED AT START OF FINI5HED BASEMENT Q CONSTRUCTION. ARCHITECT 15 TO BE 500 SOFT. x 0.093 -- "74.4 z � NOTIFIED IMMEDIATELY OF ANYO z NOTE: ALL PERIMETER SQUARE METERS _ O V15CREPANCIES45" to z v O PARTITION WALL-2„ q, x 4 ACO Lumens = "i4,4(Ix) X 42.4 s .m . _ BOTTOM PLATE, 2” X 4" WOOD 3,154.56 (Im) REQUIRED N — O NOTE: UPGRADE EXISTING STUDS ® 161, O.G. PROVIDE R-15 O Z Z Z_ CONDITIONS To MATCH KRAFT-FACED BATT INSULATION PROVIDE AT LEAST 4 led bulbs z O O CONDITIONS INDICATED ON AND 1/2" INTERIOR GYP. BD. = 3200 lumens O W O W W X (3 PLANS. " TOP TOPSOIL 0- U 0 n UJ z FINISHED BASEMENT PLAN BUILT IN �° LADDER � /' O N (°`� N N ry i1 �_ c4` O p t i LI) 55r-.ALE 1/4"= 1'-0" �N n N 0 it 6" MIN. w ; > EXIST. 2"X5" F.J. a Ib" O.G. V.I.F. '7'-6" G.H. &"X8" I —E3EAM (PLAT 2 "X4" AE30\/E) d- 0 0 0 0 o � v(cF0 0 �0 ;" / / �> EXIST 1 NC FOUNDATION WALL W 1 TH POURED �(� �° o0 o° %O CJ c4 / i2"/PEA STONE in 00 LU BACKFILL / f GONGRETE F0071NO N.I .P.). , l�z REG, . �� FERIMETER PARTITION I -'-5 " GLC. H7. WALL-2 " x 4" AGCQ WOOD STUDS © 1(oO.G. PROYI D O o , O / �� j IL Q O- -F AG E D BATT CONNECTED TO FOUNDATION o� RAINAee PIPE,/ / (� Z —I K RA P T t- ° i" /DRAINAGE SYSTEM.% INSULATION AND 1/211 INTERIOR GYP. 5D. (SES �-- ' 'O SPECIFICATION AND O NOTES) OL GROSS SECTION EC RF.SS lel I NDON DETAIL o z cv r Z � N Q � w z SCALE I/4"= I'-O" SCALE 114"= 1'-0" # --1 O Q k!) p GENERAL CONDITIONS UNLESS OTHERWISE NOTED, GENERAL FIRE BLOCKING 2020 NY5ECO -AIR LEAKAGE: 2020 EGG OF NEW YORK STATE: MINIMUM DESIGN DEAD LOADS* A5 PER ASCE n. , CONDITIONS OF THE CONTRACT FOR FIRE BLOCKING SHALL BE PROVIDED, INSULATION -JOINTS, PENETRATIONS, AND ALL R401.3: PERMANENT CERTIFICATE - SHALL BE COMPLETED BY THE 7-I6 - CHAPTER 5 TABLE 05.1 CONSTRUCTION, AIA DOCUMENT-201 AS PER SECTION R502.13 OF THE ALL EXTERIOR WALLS AND ROOFS OTHER SUCH OPENINGS IN THE BUILDER OR REGISTERED DE51ON PROFESSONAL AND POSTED IN 4/87 SHALL APPLY. THE CONTRACTOR LOAD ., RESIDENTIAL CODE OF NEW YORK SHALL BE INSULATED WITH FOIL BUILDINGS ENVELOPE THAT ARE THE UTILITY ROOM OR OTHER APPROVED LOCATION INSIDE THE COMPONENT <� ! SHALL OBTAIN CERTIFICATE OF STATE, TO GUT OFF ALL CONGEALED FACED FIBERGLASS BATT INSULATION SOURCES OF AIR LEAKAGE MUST BE BUILDING. (psf) ;": OCCUPANCY. SUBSTITUTIONS SHOULDVERTICAL DRAFT OPENINGS (BOTH BY JOHN MANVILLE OR APPROVED SEALED. G E I L I N G S cr•;.r,�.�r.:i'i : NOT BE MADE WITHOUT WRITTEN AND HORIZONTAL). EQUAL, FOIL TO BE PLACED TOWARD -RECESSED LIGHTS MUST BE TYPE IG R402.2.4: ATTIC OR CRAWL SPACE ACCES5 - SHALL BE 1 ` ` ` ` p ` AUTHORIZATION BY THE ARCHITECT. PROVIDE FIRE BLOCKING IN WARM SIDE. PROVIDE 11/2" RIGID RATED AND INSTALLED WITH NO WEATHER-STRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO ACOUSTICAL FIBER BOARD 1.0 THE PREMISES SHALL BE KEPT CONGEALED SPAGE5 OF STUD WALLS FOAM INSULATION ON ALL EXTERIOR PENETRATIONS, OR TYPE IG OR NON-IC THE INSULATION ON THE SURROUNDING SURFACES. GYPSUM BOARD (per j INCH thickness) 0.55 TODD O'CONNELL,AIIA REASONABLY GLEAN AT ALL TIME5. AND PARTITIONS, INCLUDING FURRED FOUNDATION WALLS FROM FOOTING RATED INSTALLED INSIDE AN (1/2 INCHES) (2.2) AT THE COMPLETION OF WORK, THE 5PAGE5 AT THE CEILING AND FLOOR TO 6"BELOW FIN15HED GRADE UNLESS APPROPRIATE AIR-TIGHT ASSEMBLY R402.4: AIR LEAKAGE - BUILDING THERMAL ENVELOPE SHALL BE (5/8 INCHES) (2.'75) 1200 Veterans Memorial Highway CONTRACTOR SHALL REMOVE ALL LEVELS. CONGEALED HORIZONTAL OTHERWISE SPECIFIED. CARE SHOULD WITH 0.5" CLEARANCE FROM CONSTRUCTED TO LIMIT AIR LEAKAGE TO < 3 AIR CHANGES PER MECHANICAL DUCT ALLOWANCE 4.0 Suite 124 WASTE MATERIALS, TOOLS, RUBBISH, FURRED SPACES SHALL ALSO BE FIRE BE TAKEN NOT TO DAMAGE COMBUSTIBLE MATERIALS AND 3" HOUR. Hauppauge,NY 11788 ETC., GLEAN GLASS AND LEAVE WORK BLOCKED AT INTERVALS NOT FOUNDATION WATERPROOFING. CLEARANCE FROM INSULATION SUSPENDED STEEL CHANNEL SYSTEM 2.0 BROOM GLEAN UNLE55 OTHERWISE WOOD FURRING SUSPENSION SYSTEM 2.5 P(631)650-6666 SPECIFIED. THE CONTRACTOR SHALL EXCEEDING 10 FEET. 8402.4.1.1: INSTALLATION - THE COMPONENTS OF THE BUILDING F(631}65Q-6+:�i67 CARRY WORKMAN'S COMPENSATION GLASS WINDOWS AND DOORS VAPOR RETARDER: THERMAL ENVELOPE SHALL BE INSTALLED IN ACCORDANCE WITH C(516)653-f1325 AND GENERAL LIABILITY INSURANCE. PLUMBING TO BE INSTALLED AS PER SECTION -REQUIRED ON THE WARM-IN-WINTER THE CRITERIA L15TED IN TABLE 402.4.1.1. WHERE REQUIRED BY G O V E R I N G S, ROOF, AND WALL CONTRACTOR SHALL INSTALL WATER R308 OF THE RESIDENTIAL CODE OF 51DE OF ALL NON-VENTED FRAMED CODE OFFICIAL, AN APPROVED THIRD PARTY SHALL INSPECT ALL ALL SHALL COMPLY WITH STATE AND SUPPLY AND SANITARY SYSTEM AS NYS. ALL OLA55 IS TO BE INSULATED CEILINGS, WALLS, AND FLOORS. COMPONENTS AND VERIFY COMPLIANCE. ASPHALT SHINGLES 2.0 LOCAL CODES AND ORDINANCES. THE INDICATED. PROVIDE HOT AND GOLD LOW-E UNLE55 OTHERWISE SPECIFIED. GYPSUM 5HEATHIN6, 1/2-in. 2.0 CONTRACTOR SHOULD FULLY SHUT-OFF VALVES AT ALL FIXTURES. GLAS5 SUBCONTRACTOR SHALL NOT MATERIALS IDENTIFICATION: R402.4.1.2: TESTING - BUILDING OR DWELLING UNIT SHALL BE INSULATION, ROOF BOARDS (per Inch thickness) GUARANTEE HIS WORK AND THE WORK ALL WATER PIPING TO HAVE INSTALL GLASS UNTIL PROPER -MATERIALS AND EQUIPMENT MUST BE TESTED AND VERIFIED AS HAVING < 3 ACH50 IN CZ4A, 5, AGA. FIBERBOARD OF H15 SUBCONTRACTORS FOR A CLEANOUT5 AT ALL CHANGES OF CLEARANCES ARE PROVIDED. ALL INSTALLED IN ACCORDANCE WITH THE TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY. PERLITE 1 . PERIOD OF ONE YEAR AFTER DIRECTION AND AT BASE OF SLIDING GLASS DOORS SKYLIGHTS MANUFACTURER'S INSTALLATION POLYSTYRENE FOAM 00.2 COMPLETION OF THE PROJECT UNLESS URETHANE WITH FOAM FOAM 0.5 OTHERWISE SPECIFIED. ALL WORK VERTICAL WASTES. USE 4" CAST IRON AND/OR WINDOWS AS REQUIRED BY INSTRUCTIONS. 8402.4.4: COMBUSTION CLOSETS - ROOMS CONTAINING SHALL IS PERFORMED IN THROUGH FOUNDATION WALL PITCHED CODE, SHALL BE INSULATED -MATERIALS AND EQUIPMENT MUST FUEL-BURNING APPLIANCES REQUIRE SPECIAL CARE. PLYWOOD (per 1/8-in. THICKNESS) 0.4 ACCORDANCE WITH GOOD BUILDING MIN. I/8" PER FOOT. TRAP/WASTE TEMPERED GLASS. ALL GLASS DOORS IDENTIFIED 50 THAT THE COMPLIANCE EXCEPTION: DIRECT VENT APPLIANCES WITH BOTH INTAKE AND RIGID INSULATION, 1/2-in. 0.75 PRACTICES. THE CONTRACTOR SHALL SIZES FOR FIXTURES SHALL BE AS AND WINDOWS SHALL BE INSTALLED IN CAN BE DETERMINED. EXHAUST PIPES INSTALLED CONTINUOU5 TO THE OUTSIDE SKYLIGHT, METAL FRAME, " WIRE GLA55 8.0 INDEMNIFY AND HOLD HARMLESS THE FOLLOWS: STRICT ACCORDANCE WITH THE -MANUFACTURER MANUALS FOR ALL OWNER, ARCHITECT, AND THEIR DI5H WASHER 1 1/2" MANUFACTURES SPECIFICATIONS. ALL INSTALLED HEATING AND COOLING 8403.3.2: DUCT SEALING - DUCTS, AIR HANDLER5, AND FILTER WOOD SHEATHING (PER INCH THICKNESS) 5.0 ' AGENTS AND EMPLOYEES FROM AND KITCHEN SINK 1 1/2" WINDOWS ARE TO BE CAULKED AND EQUIPMENT AND SERVICE WATER BOXES SHALL BE SEALED. WATERPROOFING MEMBRANE LAVATORY 1 1/4" SEALED AS PER 2020 NYSECC HEATING EQUIPMENT MUST BE BITUMINOUS, SMOOTH SURFACE AGAINST ALL CLAIMS, DAMAGES, 1.5 LOSES AND EXPENSES, INCLUDING SHOWER 2„ -REQUIREMENTS. PROVIDE FLASHING PROVIDED. 8403.3.3: DUCT TESTING DUCTS SHALL BE PRESSURE TESTED TO SINGLE-PLY SHEET WATERPROOFING MEMBRANE 0.7 ATTORNEYS FEES ARISING OUT G OR TOILET 3" PANS UNDER ALL SLIDER, DOORS, AND -INSULATION R-VALUES AND GLAZING DETERMINE AIR LEAKAGE. FLOOR FILL RESULTING FROM THE PERFORMANCE ALL SYSTEMS TO HAVE ONE 3" MAIN WINIDOW5 WITHIN A 6" OF AN EXTERIOR U-FACTORS MUST BE CLEARLY EXCEPTION: DUCT LEAKAGE TEST 15 NOT REQUIRED WHERE OF THE WORK PROVIDED THAT ANY VENT 5TACK INCREASED TO 4" SURFACE. ALL EXTERIOR DOORS ARE MARKED ON THE BUILDING PLANS OR THE DUCTS AND AIR HANDLERS ARE LOCATED ENTIRELY WITHIN LEIOHT WEIGHT CONCRETE, PER INCH 8.0 to SUCH CLAIM, DAMAGE, LOSS OR THROUGH THE ROOF. PROVIDE FROST TO BE FULLY WEATHER-STRIPPED. SPECIFICATIONS. THE BUILDING THERMAL ENVELOPE. SAND, PER INCH 8.0 r PROOF HOSE-BIBS AS INDICATED ON PROVIDE ALL SCREENS AND ty EXPENSE (A) 15 ATTRIBUTABLE TO STONE CONCRETE, PER INCH 12.0 BODILY INJURY, SICKNESS, DISEASE PLANS WITH EA51LY ACCESSIBLE HARDWARE AS REQUIRED. ALL GLASS DUCT INSULATION: R403.3.5: BUILDING CAVITIES - SHALL NOT BE USED AS DUCTS OR OR DEATH OR TO INJURY TO OR DRAIN DRAIN-COCK5. THE WATER IS TO BE FREE OF 5CRATCHE5 AND -SUPPLY DUCTS IN UNCONDITIONED PLENUMS FLOORS AND FLOOR F I N 15 H E 5 Z DESTRUCTION OF TANGIBLE PROPERTY SUPPLY AND SEWAGE DI5P05AL IMPERFECTIONS AND GUARANTEED BY ATTICS OR OUTSIDE THE BUILDING CERAMIC OR QUARRY TILE (3/4-In.) v (OTHER THAN THE WORK ITSELF SYSTEM SHALL COMPLY TO THE THE MANUFACTURER FOR A PERIOD OF MUST BE INSULATED TO R-8. R403.4: MECHANICAL SYSTEM PIPING INSULATION - CARRYING ON CERAMIC n. MORTAR BED 16.0 J INCLUDING THE LOSS OR USE APPLICABLE COUNTY DEPARTMENT OF NC LE55 THAN 5 YEARS. ALL WINDOWS -RETURN DUCTS IN UNCONDITIONED FLUIDS >105°F OR <55°F, INSULATE TO R-3 4N. RESULTING THERE FROM). (B) 15 HEALTH STANDARDS AND TO BE ANDERSEN UNLESS INDICATED ATTICS OR OUTSIDE THE BUILDING CERAMIC OR QUARRY TILE (3/4-1n.) REGULATIONS. APPROVAL OF ALL OTHERWISE. MUST BE INSULATED TO R-4. R403.6: MECHANICAL VENTILATION - THE SuiLDING SHALL BE ON I-In. MORTAR BED 25.0 CAUSED IN WHOLE OR IN PART BY ANY PLUMBING MUST BE OBTAINED FROM -SUPPLY DUCTS IN UNCONDITIONED PROVIDED WITH VENTILATION THAT MEETS THE REQUIREMENTS OF vZ ii NEGLIGENT ACT OR OM155ION OF THE APPROPRIATE LOCAL AUTHORITIES SPACES MUST BE INSULATED TO R-8. IRO/IMG. CONCRETE FILL FINISH (PER INCH THICKNESS). I.O IL CONTRACTOR, ANY 5UBCONTRAC7OR, PRIOR TO CONGEALMENT. PRIOR TO -RETURN DUCTS IN UNCONDITIONED THE MECHANICAL VENTILATION RATE SHALL BE NO GREATER HARDWOOD FLOORING, 7/7-in. 4.0 ANYONE DIRECTLY OR INDIRECTLY PAINTING AND STAINING SPACES (EXCEPT BASEMENTS) MUST THAN ORDERING, CONTRACTOR SHALL LINOLEUM OR ASPHALT TILE, I/4-in. 1.0 EMPLOYED BY ANY OF THEM, ORTHE FOLLOWING IS INCLUDED FOR THE BE INSULATED TO R-2. O.OI X GFA + 7.5 X (# OF BEDROOMS I) ANYONE FOR WHOSE ACTS ANY OF o SUPPLY GUTS OF FIXTURES FOR CONVENIENCE OF THE PAINTING MARBLE AND MORTAR ON STONE-CONCRETE FILL 33.0 OWNERS APPROVAL. IN THE EVENT -INSULATION IS NOT REQUIRED ON GFA = CONDITIONED FLOOR AREA THEM MAY BE LIABLE REGARDLESS CONTRACTORS AND ONLY AS AN RETURN DUCTS IN BASEMENTS. SLATE (PER mm THICKNESS) 15.0 THAT THE OWNER CHANGES, THE o � OF WHETHER OR NOT IT 15 CAUSED IN INDICATION OF THE TYPES OF PAINTS �,o d o } CONTRACTOR SHALL CREDIT THE R403.7: EQUIPMENT SIZING - PER ALGA M/NUEL 5, BASED ON 50LID FLAT TILE ON I-In. MORTAR BASE 23.0 ,�► o PART BY A PARTY INDEMNIFIED REQUIRED FOR VARIOUS SURFACES. IT DUCT CONSTRUCTION: LOADS CALCULATED PER ALGA MANUEL J. ~MmLOL, v z u V u°• N OWNER FOR THE FULL 15 THE INTENT OF THESE 5UBFLOORING 5/4-in. 3.0 W Q zm� b HEREUNDER. ALL MATERIALS, SUBGONTRAGTORS COST FOR THE -ALL JOINTS, SEAMS, AND m� tU ASSEMBLIES, AND METHOD OF SPEGIFIGATIONS TO PROVIDE A CONNECTIONS MUST BE SECURELY 8404.1: LIGHTING - A MINIMUM OF 7590 OF PERMANENTLY FLOORS HOOn JOIST (no luster) 12-In. Ib-In. oin ko CHANGED UNIT. P O.G. O.G. Z a ~ 0 CONSTRUCTION INCLUDING BUT NOT COMPLETE FINISH. ALL PAINTED FASTENED WITH WELDS, GASKETS, INSTALLED FIXTURES MUST HAVE HIGH-EFFI;ANGY LAMPS. J015T SIZES (in.) (Ls/FT2) (L5/rT2) °-�*�z� �z W v LIMITED TO FORM-WORK, SURFACES MUST BE FULLY COVERED - wtu HVAC MASTICS (ADHESIVES), LOWVOLTAGE LIGHTING EXEMPT BLOCK-WORK, FRAMING, NAILING, SYSTEM TO BE DESIGNED BY OTHERS. IN A UNIFORM MANNER TO BE MASTIC-PLUS-EMBEDDED-FABRIC, OR 2x6 PLACING OF CONCRETE, ETC. ARE TO PROVIDE PROPER SUPPLY TO ALL ACCEPTABLE. TAPES. DUCT TAPE 15 NOT2x8 6 6 4 d d z o BE CAREFULLY SUPERVISED BY THE ROOMS CONFORM WITH ALL STATE INTERIOR WOOD SURFACES-APPLY TO PERMITTED. 2020 RESIDENTIAL CODE OF NEW YORK SATE SECTION R308- CONTRACTOR TO BE SURE THEY ARE AND LOCAL CODES. LIGHTLY SANDED SURFACES, WALLS, EXCEPTION: CONTINUOUSLY WELDED GLAZING 2x10 7 6 N z o z o m IN ACCORDANCE WITH THE DRAWINGS, DOORS, FRAMES, TRIM, AND BASES, AND LOOKING-TYPE LONGITUDINAL 2x12 8 7 SPEGIFIGATIONS, APPLICABLE CODES ONE GOAT WOOD FILLER OR STAIN - EXCEPT AS INDICATED IN SECTION 8,08.1.1 EACH PANE OF d m o iL o o o FRAMING AND ROUGH CARPENTRY JOINTS AND SEAMS ON DUCTS GLAZING INSTALLED IN HAZARDOUS LOCATONS AS DEFINED IN FRAME PARTITIONS ( sf) - °aF AND GOOD PRACTICE. DEVIATIONS JOISTS RAFTERS AND STUDS SHALL AND TWO GOATS MGKLU5KY S OPERATING AT LESS THAN 2" w. - d m 4 9' SECTION 8308.4 SHALL BE PROVIDED WITf A MANUFACTURE 5 WOOD OR STEEL STUD5, I/2-In. GYP. BOTH SIDES 8.0 w o u FROM THE DRAWINGS AND EGGSHELL FINISH NON-YELLOWING Wo> o u° F BE CONSTRUCTION GRADE DOUGLAS (500 PA.) DESIGNATION SPECIFYING WHO APPLIED TH° DESIGNATION WOOD STUDS 2x4 UNPLASTERED aw wv w SPECIFICATIONS WILL NOT BE POLYURETHANE. 4.0 m F FIR-SOUTH SELECT STRUCTURAL. ALL -DUCTS SHALL BE SUPPORTED EVERY DESIGNATING THE TYPE OF GLASS AND THI SAFETY GLAZINGPERMITTED WITHOUT WRITTEN GYPSUM BOARD- MINIMUM ONE GOAT FRAME WALLS `"`" d �' z o WOOD SILLS AND WOOD IN CONTACT 10 FEET OR IN ACCORDANCE WITH THE STANDARD WITH WHICH IT COMPLIES, WHICH I5 VISIBLE IN THE FINAL z o} AUTHORIZATION OF THE ARCHITECT. PRIMER AND TWO GOATS FLAT PAINT. WITH MASONRY SHALL BE AGQ. ALL MANUFACTURER'S INSTRUCTIONS. INSTALLATION. THE DESIGNATION SHALL BE ACID ETCHED EXTERIOR STUD WALLS: THE CONTRACTOR SHALL BE EXTERIOR WOOD SURFACES- TWO � �a��'��� z� � X EXTERIOR SHEATHING SHALL BE 1/2 -COOLING DUCTS WITH EXTERIOR SANDBLASTED CERAMIC-FIRED LASER ETCHED EMBOSSED OR BEA °d x d j2�x d RESPONSIBLE FOR THE SHOP GOATS EXTERIOR GRADE STAIN. 2x4 ® I6-in., 5/8-1n. GYPSUM, w w w d w` ,3 GDX DOUGLAS FIR PLYWOOD. INSULATION MUST BE COVERED WITH A TYPE THAT ONCE APPLIED CANNOT BE REK' VED WITHOUT BEING I I.O `�Z 0 o DRAWINGS WHICH MAY BE NEEDED. SUB-FLOORS TO BE 3/4" GDX EXTERIOR EXPOSED METAL- MINIMUM VAPOR RETARDER. ,� INSULATED, 3/8-In. SIDING ��d d�m o°�o� p ALL DIMENSIONS AND CONDITIONS ONE GOAT ZING CHROMATE AND TWO DESTROYED. A LABEL SHALL BE PERMITTED IN LIEU OF THE PLYWOOD EXTERIOR SHE TO -AIR FILTERS ARE REQUIRED IN THE MANUFACTURE'S DESIGNATION 2x6 ® Ib-in., 5/8-In. GYPSUM, ARE TO BE FIELD VERIFIED. GOATS EXTERIOR ENAMEL. 12 O ARE 70 CONTRACTOR TO REMOVE BE COVERED WITH TYVEK HOUSE RETURN AIR SYSTEM. R308.4 HAZARDOUS LOCATIONS - THE LOCATIONS SPECIFIED IN INSULATED, 5/8-In. 51DINO Y ALL MATERIAL SHALL BE OF BEST WRAP OR APPROVED EQUAL. BLOCK -THE HVAC 5Y5TEM MUST PROVIDE A SECTIONS R308.4.1 THROUGH R308.4.7 SHALL BE CONSIDERED TO BE V V N N RELOCATE AS REQUIRED ALL QUALITY PITTSBURGH, PRATT EXTERIOR STUD WALLS WITH BRICK VENEER 48.0 EXISTING WORK WHICH INTERFERES STUD WALLS AT I/2 STORY HEIGHTS MEANS FOR BALANCING AIR AND SPECIFIC HAZARDOUS LOCATIONS FOR THF PURPOSE OF GLAZING AND AT ALL UNSUPPORTED EDGES OF LAMBERT, DUTCH BOY. CABOT5, WATER SYSTEMS. WINDOWS, GLASS, FRAME AND SASH WITH NEW CONSTRUCTION. MCKLU5KYS, OR APPROVED EQUAL. 8308.4.1- GLAZING IN DOOR- GLAZING IN FXED AND OPERABLE 8.0 PLYWOOD. PROVIDE SOLID BLOCKING CONTRACTOR 15 TO PROVIDE PANEL OF SWINGING, SLIDING AND Blf'OLD POOR5 SHALL BE CLAY BRICK WYTHE5: AND DIAGONAL BRACING OF FLOOR TEMPERATURE CONTROLS: CONSIDERED TO BE A HAZARDOUS LOGATON 4 IN 39.0 SITE WORK JOISTS AT 8' O.G. MAXIMUM AND SAMPLES ALL PAINTS AND STAINS _EACH DWELLING UNIT HAS AT LEAST FOR ARGHITEGT 5 AND/OR OWNERS 8308.4.2- GLAZING ADJACENT TO DOOR-GLAZING IS LE55 THAN 60 8 IN '19.0 STAKEOUT 15 TO BE PERFORMED BY A SOLID BLOCKING UNDER ALL APPROVAL. ONE THERMOSTAT CAPABLE OF INCHES ABOVE THE FLOOR OR WALKING 5LRFACE AND IT MEETS 12 IN 115.0 LICENSED SURVEYOR. STAKING AND UNSUPPORTED EDGES OF PLYWOOD. AUTOMATICALLY ADJUSTING THE EITHER OF THE FOLLOWING- I6 IN 155.0 LAYOUT ARE TO ESTABLISH ALL LINES ALL GAP PLATES TO BE DOUBLED SPACE TEMPERATURE SET POINT OF - GLAZING IS WITH 24" OF EITHER SID: OF THE DOOR HOLLOW CONCRETE MASONRY UNIT WYTHE5: z GYPSUM WALL BOARD W AND BENCHMARKS. VERIFY ALL GIVEN AND NAILED BOTTOM GAP PLATED TO THE LARGEST ZONE. -GLAZING 15 ON A WALL PERPENDICULAR TO THE PLANE OF THE WYTHE5 THICKNESS (IN INCHES) 4 6 8 10 12 0 INSTALLED AS PER SECTION R702.3.2. DATA ON DRAWINGS. IN CASE OF END OF STUD5. LAP GAP PLATES AT + v z0 DISCREPANCY, THROUGH R702.3.6 OF THE NEW YORK DOOR IN A CLOSED POSITION AND WITHIN .4 OF THE HINGED 51DE OF DENSITY OF UNIT (105 PGF) RECEIVE CORNERS. WHERE FLUSH FRAMING ELECTRIC SYSTEMS: AN IN-SWING DOOR NO GROUT STATE RESIDENTIAL CODE. GYPSUM 22. 24.0 51.0 37.0 45.0 1 p 1- CLARIFICATION FROM ARGHITEGT OCCURS, USE MIN. 16GA SHEET METAL -SEPARATE ELECTRIC METERS ARE 8308.4.3- GLAZING IN WINDOW WALLBOARD APPLICATION SHALL BE PRIOR TO PROCEEDING. EXCAVATE JOIST HANGERS BY "TECO" OR REQUIRED FOR EACH DWELLING UNIT. - EXPOSED AREA OF AN INDIVIDUAL PANE15 LARGER THAN 9 5Q.FT. (GROUT SPACING) O p Q TAPE JOINT SYSTEM. ALL GYPSUM AND BACK FILL FOR WORK INDICATED APPROVED EQUAL. ALL CORNERS TO BOARD TO BE I/2" ON WALLS AND I/2" -BOTTOM EDGE OF GLAZING IS LESS THAN18" ABOVE THE FLOOR 48 IN. O.G. 29.0 55.0 41.0 55.0 Q F- ON DRAWINGS. STOCKPILE TOPSOIL BE MINIMUM 3/2X4 STUDS. HEADERS ON CEILINGS UNLE55 OTHERWISE FIREPLACES: - TOP EDGE OF GLAZING IS MORE THAN 5F " ABOVE FLOOR AND 40 IN. O.G. 0.0 40.0 49. 57.0 OBTAINED FROM STRIPPING DRIVEWAY SHALL BE MINIMUM 2/2X6 UNLESS INDICATED. FINISH JOINTS, J-BEADS. -FIREPLACES MUST BE INSTALLED 52 IN. O.G. 52.0 42.0 52. 61.0 ONE OR MORE WALKING SURFACES ARE WI'HIN 36 MEASURED O z z z 24 IN. O.G. AND BUILDING SITE. STOCKPILE ALL NOTED ON PLANS. MINIMUM BEARING NAIL DIMPLES CORNERS AND EDGES WITH TIGHT FITTING NON-COMBU5TABLE HORIZONTALLY AND IN A STRAIGHT LINE G= GLAZING 54.0 46.0 57.0 67.0 �- O O I6 IN. o. G. 40.0 55.0 bb.0 79.0 z X O EXCAVATED MATERIAL. NEW AND FOR STUDS, JOISTS AND BEAMS SHALL FIREPLACE DOORS (X SHALL BE TAPED AND RECEIVE THREE 308.4.4- GLAZING IN GUARDS AND RAILINGS FULL GROUT 55.0 •75.0 95.0 115.0 W O W to EXISTING BACK FILL MATERIAL AND BE 3 1/2". USE DOUBLE JACK STUDS -FIREPLACES MUST BE PROVIDED TOPSOIL ARE TO BE FREE OF WEEDS, FOR HEADERS OVER FIVE FEET IN GOATS OF JOINT COMPOUND. ALLOW WITH A SOURCE OR COMBUSTION AIR, 8308.4.5- GLAZING AND NET SURFACES- 3ATHTUBS, SHOWERS WHERE (L v O D W z THE BOTTOM EXPOSED EDGE OF GLAZING S LESS THAN 60 INCHES DENSITY OF UNIT (125 PGF)- SEE ASCE 5TANDARD - MINIMUM DESIGN 24 HOURS TO DRY BETWEEN GOATS. p13 TREE ROOTS, ROCKS AND DEBRIS. LENGTH. FINAL COAT TO BE SANDED SMOOTH. AS REQUIRED BY THE FIREPLACE MEASURED VERTICALLY ABOVE ANY STANDING OR WAL,;KING DENSITY OF UNIT (155 PGF) LOAD FOR BUILDING 5TRUGTURE5 AND tv cv cv ry n ALL SURPLUS MATERIAL THAT 15 CONSTRUCTION PROVISIONS OF THE different dead load OTHER STRUCTURES -ASGE-1-I6 UNSUITABLE FOR BACK FILL MATERIAL NOTE: METAL CORNER BEAD TO BE USED ON SURFACE BUILDING CODE OF NEW YORK STATE, _ R308.4.6 GLAZING ADJACENT TO STAIRS AND RAMPS- GLAZING values for differ (PGF) p 'm r aui Q ALL OUTSIDE CORNERS AND AROUND SHALL BE REMOVED FROM THE SITE. FOUNDATIONS CHAPTER 4 DESIGN THE RESIDENTIAL CODE OF NEW YORK n Q ALL OPENINGS. WHERE THE BOTTOM EXPOSED EDGE OF TE GLAZING 15 LESS THAN SOLID CONCRETE MASONRY UNIT WYTHE5: � � � � `A PROTECT ALL TREES WITHIN EIGHT BASED UPON PRESUMPTIVE LOAD STATE OR THE NEW YORK CITY 36" ABOVE THE PLANE OF THE ADJACENTWALKING SURFACE OF FEET OF THE BUILDING. PROPER BEARING VALUES OF SANDY GRAVEL BUILDING CODE, AS APPLICABLE. WYTHE5 THICKNESS (IN mm) 4 6 8 l0 12 ELECTRICAL STAIRWAY, LANDING BETWEEN FLIGHTS ORSTAIRS OR RAMPS DENSITY OF UNIT (105 PGF) # APPROVALS MUST BE OBTAINED AND/OR GRAVEL AT 2000 LB5 PER 52. 51.0 69.0 87.0 105.0 ALL WORK SHALL COMPLY WITH THE -GLAZING 36 OR LESS MEASURED HORIZONTALLY FROM THE DENSITY of UNIT (155 PCF) > BEFORE COVERING ANY EXCAVATED SQUARE FOOT. CONTRACTOR TO NATIONAL ELECTRICAL GODS AND ALL SERVICE WATER HEATING: WALKING SURFACE 38.0 60.0 81.0 102.0 124.0 WORK. DENSITY OF UNIT (155 PGF) CONSULT ENGINEER IF DIFFERENT SOIL -WATER HEATERS WITH VERTICAL 41.0 4.0 87.o Ilo.o 133.0 STATE _COAL AND UTILITY COMPANY R308.4.7 GLAZING ADJACENT TO THE BOTOM STAIR LANDING MATERIALS ARE FOUND UPON PIPE RISERS MUST HAVE A HEAT TRAP * WEIGHTS OF MASONRY INCLUDE MORTAR BUT NOT PLASTER. FOR CODES AND REGULATIONS. ALL - WHERE GLAZING IS LESS THAN 36" ABONE THE LANDING AND WITHIN CONCRETE BLOCK EXCAVATION OR TEST HOLE, FOR ON BOTH THE INLET AND THE OUTLET PLASTER, ADD 5 Ib/ft2 FOR EACH FACE PLASTERED. VALUES CIRCUITS SHALL BE MINIMUM 15 AMP. A 60 HORIZONTAL ARE LE55 THAN 180 CGREES FROM THE BOTTOM Z ALL CONCRETE BLOCK 15 TO HAVE ALTERNATIVE FOOTING AND POWER WIRING SHALL BE MINIMUM 14 UNLESS THE WATER HEATER HAS AN TREAD NOSING OIVS CONREPRESENT A SOME CASES SAME ERE 15 CONSTRUCTION. DUR-O-WALL REINFORCING EVERY FOUNDATION WALL DE51ON INTEGRAL HEAT TRAP OR 15 PART OF CONSIDERABLE RANOE WEIGHT THIRD COURSE. FILL TOP COURSE AWG. CONVENIENCE OUTLETS SHALL 1lI BE LOG4TED 12 ABOVE FINISHED A GIRGULATING SYSTEM. SOLID. MORTAR MIX TO BE ONE PART -INSULATE CIRCULATING HOT WATER NOTE: WINDOW FALL PROTECTION TO BE 'ROVIDED : FLOOR UNLESS OTHERWISE INDICATED. FOR ALL WINDOWS AS PER 2020 RESIDENTIAL CODE OF NEW YORK STATE SECTION R305.1 l l PORTLAND GEMENT, ONE PART LIME NOTEALL NON-ENGINEERED LUMBER ALL SW'TGHED TO BE LOCATED 36" PIPES TO THE LEVELS ON TABLE I. TO BE DOUGLAS FIR #2 OR BETTER �-/ PUTTY, AND 51X PARTS SAND, OR ONE PART MASONRY GEMENT AND THREE ABOVE THE FINISHED FLOOR UNLESS GIRGULATING HOT WATER SYSTEMS: 2020 RESIDENTIAL GORE OF NEW YORK ;TATE SECTION R312.2 MINIMUM HEIGHT- CEILING- HABITABLE SPACE, HALLWAYS AND ly PARTS SAND. OTHERViISE INDICATED. SUPPLY -INSULATE GIRGULATING HOT WATER PORTION OF BASEMENTS CONTAINING THESE SPACES SHALL HAVE A ' I ' _ RECOMMENDED LAMPS IN ALL PIPES TO THE LEVELS ON TABLE I. - IN DWELLING UNITS WHERE THE TOP OF 74E SILL OF AN OPERABLE CEILING HEIGHT OF NOT LE55 THAN 7 FEET. BATHROOMS, TOILET CQ J-4--1-n, FIXTURES. WINDOW OPEV OPENING IS LOCATED LE55 THAN24 INCHES ABOVE THE ROOMS, LAUNDRY ROOMS SHALL HAVE A CEILING HEIGHT OF NOT HEATING AND COOLING PIPING FINISH FLOOR AND GREATER THAN 72 INC+E5 ABOVE FIN15H GRADE LESS THAN 6 FEET 8 INCHES Q Q Z INSULATION: OR SURFACE BELOW THE EXTERIOR OF TF_ BUILDING EXCEPTION: -HVAC PIPING CONVEYING FLUIDS -THE OPERABLE WINDOW SHALL COMPLY JITH: I. FOR ROOMS WITH SLOPED CEILINGS THE REQUIRED FLOOR TAELE I: MINIMUM INSULATION THICKNESS FOR CIRCULATING HOT WATER PIPES Z OPERABLE WINDOW THAT ARE ROVIDED WITH WINDOW AREA OF THE ROOM SHALL HAVE A CEILING HEIGHT OF NOT ABOVE 105°F OR CHILLED FLUIDS INSULATION THIGKNE55 IN INCHES BY PIPE SIZES BELOW 55°F MUST BE INSULATED TO OPENING CONTROL DEVICES THAT COMPL' WITH SEG. R312.2.2 LESS THAN 5 FEET AND NOT LESS THAN 50 PERCENT OF THE HEATED WATER NON-GIRGULATING RUNOUT5 CIRCULATING MAINS AND RUNOUT5 Z 7 THE LEVELS IN TABLE 2. REQUIRED FLOOR AREA SHALL HAVE A CEILING HEIGHT OF NOT TEMPERATURE (F) UP TO I" UP TO 1.25" 1.5" TO 2.0" OVER 2" l� O R312.2.2 WINDOW OPENING CONTROL DEVI�E5- SHALL COMPLY WITH LESS THAN FEET 1.L A5TM F2090 2. THE CEILING HEIGHT ABOVE BATHROOM AND TOILET ROOM 170-180 0.5 I.O 1.5 2.0 NOTES: THE WINDOW OPENING DEVICE AFTER OFRATION TO RELEASE THE FIXTURES SHALL BE SUCH THAT THE FIXTURE 15 CAPABLE OF 140-160 1 0.5 0.5 1.0 IS Q ZZ CONTROL DEVICE ALLOWING THE WINDOWTO FULLY OPEN SHALL NOT BEING USED FOR ITS INTENDED PURPOSE I. OBTAIN ALL PERMITS PRIOR TO 100-130 0.5 0.5 0.5 10 u 0 Old THE START OF WORK. REDUCE THE NET CLEAR OPENING AREA cF THE WINDOW UNIT TO . LESS THAN THE AREA REQUIRED BY 5ECION R310.2.1 2. ALL BEDROOM TO BE PROVIDED TABLE 2: MINIMUM INSULATION THICKNESS FOR HVAC, PIPES - WITH ROD 4 SHELF, ALL LINENO z CLOSETS TO BE PROVIDED WITH 5 PIPING SYSTEM FLUID TEMP. INSULATION THIGKNE55 IN INCHES BY PIPE 51ZE �/ ROWS OF SHELVES. TYPES RANGE (F) 12" RUNOUT I" AND LESS 1.25" TO 2" 2.5" TO 4" V 3. DOOR TRIM AND BASE MOLDING HEATING SYSTEMS !!_. TO MATCH EXISTING LOW PRESSURE/TEMPERATURE 201-250 1.0 1.5 1.5 2.0 4. ALL BATHROOM FIXTURES AND LOW TEMPERATURE 120-200 0.5 1.0 1.0 1.5 d FAUCETS TO BE SUPPLIED BY OWNER STEAM CONDENSATE N O AND INSTALLED BY CONTRACTOR (FEED WATER) ANY 1.0 1.0 1.5 2.0 0 r- z COOLING SYSTEMS it IV 5. FINISHES TO BE SUPPLIED CHILLED WATER, REFRIGERANT 201-250 1.0 1.5 1.5 2.0 lu BY OWNER AND BRINE 120-2000.5 1.0 1.0 1.5 m 0 < O Q La