Loading...
HomeMy WebLinkAbout47552-Z .r2= � S�Ffal Town of Southold 3/7/2023 ys 4, P.O.Box 1179 y x 53095 Main Rd W�y�j01 �ao� � Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43902 Date: 3/7/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1375 Sterling Rd., Cutchogue SCTM#: 473889 Sec/Block/Lot: 104.-2-24 Subdivision: I Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/14/2022 pursuant to which Building Permit No. 47552 dated 3/15/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Melly,Peter&Catherine of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47552 6/24/2022 PLUMBERS CERTIFICATION DATED Auth i ed i ature o�SUFFQi�co TOWN OF SOUTHOLD �� ay BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE WO . - SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47552 Date: 3/15/2022 Permission is hereby granted to: Melly, Peter 23 Edmarc Ct Oakdale, NY 11769 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled and readily accessible as per code. At premises located at: 1375 Sterling Rd., Cutchogue SCTM # 473889 Sec/Block/Lot# 104.-2-24 Pursuant to application dated 2/14/2022 and approved by the Building Inspector. To expire on 9/14/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector pF SO(/T�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlinCcD-town.southold.ny.us Southold,NY 11971-0959 Comm, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Peter Melly Address: 1375 Sterling Rd city:Cutchogue st: NY zip: 11935 Building Permit#: 47552 Section: 104 Block: 2 Lot: 24 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: NY State Solar License No: 62692ME SITE DETAILS X Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer LIC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 7.329kW Rood Mounted PV Solar Energy System w/ (21) SunPower 400W, AC Disconnect, Combiner Panel w/220x3 Notes: Solar Inspector Signature: Date: June 24, 2022 S.Devlin-Cert Electrical Compliance Form r4f so y�Io 4-7S5 '2- / -3 7.5 ✓ 'r4.t - # # TOWN OF SOUTHOLD BUILDING DE�. `ycou631-765-1802 INSPECTION [. ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �o ✓�-1 5 c57� / r off' AA BJpL i X12 smn6z o GW moo 72ra w/A 0 e&P� SAO(AZ WiXtC -� 2Z- DATE A INSPECTOR r OF SOUI�o * # TOWN OF SOUTHOLD BUILDING DEPT. °ycouHn��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL5jgV [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: vc� 6-1116 0 vv DATE Y- INSPECTOR L4-7 S 5 G y Pontino, Susan U From: Debra Archer <darcher@nystatesolar.com> Sent: Thursday, June 23, 2022 3:39 PM To: Pontino, Susan Cc: Permitting Subject: 1375 Sterling Rd Inspection/Permit Close Out Attachments: Melly-REVISED-Scanned (2).pdf Hi good afternoon, I just spoke with inspector Sean Devlin, in regards to revisions for a failed inspection at 1375 Sterling Rd, Cutchogue.The reason for the failure he said was that we installed 22 panels and we submitted plans and applied for 21. I'm attaching here photographs from the installation, indicating 16 panels in one array, and 5 in the other,for 21 in total (as shown on plans).The plans attached were recently mailed in but here is a digital copy for your reference. Please let me know if this is sufficient and if anything else is needed to close the permit. Thank you! Debra F' 1 y vc, a f }51 .x.. r J Debra Archer X Operations Supervisor 516-206-0601 darcherCa nystatesolar.conn ATTENTION:This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 2 F LD' . IE INSPETION:REP RT< T' .._ ,.,.,.-,.i b �.'j'�- `,!j Vit". 1 FOU I'D QN:..1ST,' " `K'' 0 % ); { FO A PION'(2ND); I- : . .:-",.. �.;. --;tl- .. ' 1';1.5,':'•1- ::::"I.;ti,.: ,..\ti.):i:7;�,�:fk. �- . :+v. moi?:'^ ^':�r''•\,•Ae.'�t:` :7.:::;� E . .-�a �Y t:. .,, '' ,,ll 1+ �9 \.�_.;.i<i;'':,f:;-io`?:>:is'",;'.,�,.,irt. .�t•Citi;,1;-<'Ij:-'i " __ .....-A. ,:Fsi:%Ci.7..1''{'.e'-y itr: ,., ,}Ic'9i: 0 hCy RQUGH.FRAIYIING;4` -' ►��yy :f, `„' Vin, :l�i:,a,:!';�':r�l'.tia yi..... .. I...1:.I ' l'� PLUIVIBZNG'' �r .-�s:'.:4: ,::: :r w,..' ter,;: +.1�: ..t s,t;;::':,"”'t. I n P t.e.'`: ,c..•, ray l„�:;i�,'•'�'.::' 1 v,;�Jp:'`..,;, .:'.:,',:?;;..:: . % f...T,--F*, l 5.!; ni.1)�.]r J+f.L. \r...r'.• ::' , .vl!:.. y; . 0 _rl f, ti .,j:, r ,:j.f- :.'r "r . ti,;�' ,,... ..r.^ j.; k'.......::t'"'`'' r - . 3� , 11— 1. INSULATION, r;.:.,i:,zr :, to :. ..: ",18 .. H. TATE EN R' I '.' : -. . ;: :i . . .. \,? . %1,:1t.'I':i:, ']�>`.r�J(, .- 'a 1 t. .p 'i i. to `%.-t% Ys' Q;:1:. '``':..r,,.. i2` . ., lz . i , ,.. �,SJ;�;:1•:'<!: x:11'.'..a':=''1'< •`.J`J.+ .i',;. 'XPi," ,Y^,YjJ...,.i..l.'.•4' .urs+.._ r^i. .,.�:7;?.��Gi.;l'i :44%:x. . FINAL ... r ;.ti:;mir :.:a; ' t',%J:,1.. 'L.,;. ',Y., �; - ]:V. .1 'i:"�, '4� r!'`'ii: "�lIina Ott., rJ; . . . . . ... -fit•: �z:�7--F.. s ri?...'':,:.:. .. .. .. .. r �. • 'y``;`, :'i!—`—q :;Gtr i:�{,:;:;i, , - . . '- .a a'. - }_—'e , r y: •:C ,t., .. - H . .. :`; . . -'. pi.;.•y:.. y :'f-,:i'.iq�n'S%o.'s`;g''1,7Ufi5cir�;-i�Y:':%��':',:fi::..`::. • '1i ;6. ii)r?,4i',.--'I;ti;:pj:i$``t,&,4.(>w_'B�.:, ,,r ;s ,. ' 'ti''' :�'I'i-1Sn�;}:."jt"S`s.�^;-11• )�A ''L:i�ii.[''iri�k!i(;.,,�'�9:., Pr, •. s t, r,),. ri'n:b•'-3"t;;',.4.f�::r,V-\.,'!_2-1:!' f•'.'.. yg�%.ri:" ;;a .L;tY 6 :Y`(�{ �, „' . . .. r j `^:;:.1, ;•I�o;sk:'r-iy'�ti;-1�.:'arF;^t., 1, . � ���r ' ?if '; c • i :' - r ." �, o�O�g�fFO(k�oGy� TOWN OF SOUTHOLD —BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o ao� Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ® E C E R V �C(L PERMIT NO. Building Inspector: FEB 20222 .Applications and forms must be filled out in their entirety. Incomplete TOWti OF G DEPT LD applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed.: Date: OWNERS)OF PROPERTY: Name: Peter & Catherine Mell _, .__._... SCTM# 1000- I G i-}...-...a. o`� _. . . Y Project Address: 1375 Sterling._Road Cutchogue, NY 11935 Phone#:(516)-635-1462Email:bammermelly@aol.com Mailing Address: 1375,Sterling..Road Cutcho ue, NY 119,35. CONTACT PERSON: Name: - P�e� Mailing Address: . Phone#:.._�� �.`. -_.��..-2..�. _�...__._.._.. ...__...... Email: . .rn `1��. .., h . . _.+ �.l011 K ,.t DESIGN PROFESSIONAL INFORMATION: Name` Pacifico Engineering PC Mailing Address:700, Lakeland Avenue, Suite 2B Bohemia,,_NY 11716 Phone#:(631)-988-0000 _ „ Email:nycsolar@pacificoengineering.com CONTRACTOR INFORMATION: . Name: Reid Garton Mailing Address: 385 W John Street Hicksville, NY 11801 Phone#: 516 -418-2131 a Email:permitting@nystatesolar.com_._ DESCRIPTION AF PROPOSED CONSTRUCTION E:1New Structure 'n 'Addition [!Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther Solar Panel.System $$35,661.65 Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Resid.ential. Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ENO IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Reid Garton ®Authorized Agent ❑Owner Signature of Applicant: / Date: Z q' Z 2- Ashley Ashley RIZZO STATE OF N E W YO R K) Notary Public,State of New York Reg.No.01 RIS426481 SS: Qualified In Nassau COunty 1211312025 CO U NTY O F M"L ck-'y ) Commission Exp f�6 -3-CAI being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, / (S)he is the Coy)-bra ,-ftSy (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 20 ZZ Notary Public BONNIE CLAIRE ZELLLNER PROPERTY OWNER AUTHORIZATION Notary Public-State of New York NO.01ZE6424367 (Where the applicant is not the owner) Qualified in Suffolk County My Commission Expires Nov 1,2025 I, 4 er/o2 residingat /05 C neje !'til L4e, Sc)q1 )l 41 1 11 g-7� do hereby authorizeto apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signafae Date a Print Owner' Name 2 jFFOL BUILDING DEPARTMENT-Electrical Inspector S � ` , TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 .... ,,l rogerr(a�southoldtownny.gov -- seand(c-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date:_3)1 s-- 20 zZ Company Name: L Stwi t, IQr Electrician's Name: , Ck ('AMn '04 License No.: Mt✓ - ((,2j0q2_ Elec. email: tli�� �US�CcveS alar_ cwn Elec. Phone No: I Cn._-1I`6--z13 El request an email copy of Certificate of Compliance Elec. Address.: 3s s- W. n St-- -\jn-A- lcx: (CILStiilo JOB SITE INFORMATION (All Information Required) Name: Address: Cross Street: Phone No.: Co -- L93F - I Z BIdg.Permit#: „44 `f-7 �2- email: J c-o(- C0 f vl Tax Map District: 1000 Section: I 0 , o o Block: 02— o 0 Lot: 02-4 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Ci rUV4- Square Footage: Circle All That Apply: Is job ready for inspection?: El YES NO R Rough In ❑ Final Do you need a Temp Certificate?: E YES©NO Issued On Temp Information: (AII information required) Service Size❑1 Ph FJ3 Ph Size: A #Meters Old Meter# ❑New ServiceE]Fire ReconnectoFlood ReconnectEService ReconnectE]Underground ElOverhead #Underground Laterals 1 F12 H Frame 0 Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION SCDHS REFf R-12-1131 �o 123.41' N /�0 3N85l4�6 00�rlcE r-<v''�� � o.ia ��% i EL. 20.5' SURVEY OF PROPERTY AT CUTCHOGUE p,o s TOWN OF SO UTHOLD . OPE o Dr�vo SUFFOLK COUNTY, N.Y. 1000-104-02-24 o �t EP M "r"'� SCALE.--V= 30' MARCH J 2021 SEPZUBER Z 2021 (FOUNDATION LOCATION) I0.0Q/o ('� rHOUSE iFoLkDATION1Y/0TOP/OUtaDAitOM 0.20.E ; TpgY r AME QI r e 99' .. 0 TEST HOLE DATA VQL MCOONALD CEOSC£NCE ® 1/20/2021 rim W= fL 19 5' 1' DARK BROWN LOAAI OL u 19 I v 'o ma a t/O BROIW SIL TY SAND SM � i faTfAYJ t `�G (�� .�• P10EL '19.7` EL.19.7• 70.oa.— 1 SB` -46.'00"W-,o--. PALE BROWN nNE SAND SP ZA- 14.6M Sa FT x,19 i STERLING +LEL ROAD . �ayu�ENr t(")Rem To IUP QNASSAU FARMS'nLLD ON +lad- `p(JgLjC WATER IN STREET F EL. 25' 1 17' 69CH 14 1935 AS FXE NO. 1179 \ NO WATER ENCOUNTERED EVATIAVS AND CONTOUR LINES ARE EFERENCED TO NAVD 1N39 '£ LOCATIONS OF WELLS AND CESSPOOLS SHOWN HEREON ARE FROM pWXLLUW FM pVWX�IFATV —� ;LD OBSERVATIONS AND OR FROM DATA OBTAINED FROM OTHERS EREFORE THEIR LOCA77ONS AND OR EXISTENCE IS NOT GUARANTEED. im familiar with the STANDARDS FOR APPROVAL AND CONSMUC17ON OF SUBSURFACE 'WAGE DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES and will abide by the editions set forth therein and on the permit to construct. The location of wells and RAIN RUNOFF CONTAINMENT sspools shown hereon are /iom field observations and or from data obtained from others. HOUSE W7TH PORCH -3,000 SOFT !� L =nr.Y.S. LIC. No. 'ALTERATION OR AD01ndY To IRIS SURVEY ISVA OLA nOIN' J,000 x 1 x 0.17 = 510 cu.lt. p aYtC r!R , YCRS P.C. SECTION 72090E THE NEW YORK STATE EDUCATION LAW. 51%2.2 - 12.1 VF CPT AS PER SECTION-7209-SUBDIW9ON 2. ALL C£RnnCAnONsPROVIDE 2 OWs. 8a X 6' DEEP (63l)�-765-4020 'r"AX (631) 765– EON ARE VAUD rOR DOS UAP AND CORES THEREOF ONLY IF P.O. 90X 909 I UAP O7 CCPI£S BEAR TIO£1UPR£SSED SEAL Or THE SURVEYOR Connected by Gutters & Leaders 1230 TRA1rFLER SHEET ISE SIGNATURE APPEARS HEREON. SCU,—HCLD. N.Y: 11971 X21-0 RI Workers' CERTIFICATE OF TATE Board ompensati®n NYS WORKERS' COMPENSATION INSURANCE COVERAGE B 1a.Legal Name b Address of Insured(use street address only) 1b.Buss Telephone Number of Insured NY State Solar LLC 516-418-2131 385 W John St,Unit 100 1c.NYS Unemployment Insurance Employer Reglatration Number of Hicksville,NY 11801 Insured Work Location of Insured(Only required If coverage Is speclficagy Mm/ted to 1d.Federal Employer Identification Number of Insured or Social Security certain locations/n New York State,l a.,a Wrap-Up Polley) Nu mber 32-0580074 2.Nance and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Indemnity Insurance Co.of North America Town of Southold 3b.Policy Number of Entity Listed in Box'1a" 54375 Route 25 WLR C68959755 P.O.Box 1179 Southold,NY 11971 3c•Policy effective period 3/1/2021 to 3/1/2022 3d.The Proprietor,Partners or Executive Officers are 0 Included.(9nly check box If all partners/officers Induded) ® all excluded or certain partnerslofNcers excluded. This certifies that the insurance carrier indicated above in box-'T insures the business referenced above in box"1a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation Insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within-10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate Is valid for one year after this form Is approved by the Insurance carrier or Its licensed agent,or until the policy expiration date listed in box"3c",whichever Is earlier. This certificate is issued as a matter of Information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is In effect. Please Note:Upon cancellation of the workers'compensation policy Indicated on this form,N the business continues,to be named on a permit,license or contract Issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Kevin Groves R0L4;0k% (Print name of���prasentatrve or rKensed agent or insurance carriar) Approved by: 11/19/2021 (signature) (Dae) Tius: Vice President I• Telephone Number of authorized representative or licensed agent of Insurance carrier.462-445_3619 Please Note:Only Insurance carriers-and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are M authorized to issue IL C-105.2(947) www.wcb.ny.gov Workers' Compensation Law Section 57. Restriction on Issue of permits and the entering into contracts unless compensation is secured. 1. The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, and notwithstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department, board, commission or office authorized or required by law to enter Into any contract for or In connection with any work involving the employment of employees in a hazardous employment defined by this chapter,notwithstanding any general or special statute requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been secured as provided by this chapter. C-105.2(94T)REVERSE - voRK` worker's" CERTIFICATE OF INSURANCE COVERAGE sTarl:; Compensation Board' DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured NYSS LLC DBA: s w.i HNAST UNITE T 00 5164182131 HICKSVILLE,NY 11801 Work Location of Insured(Only required if coverage is specifically limited to 1 c.Federal Employer Identification Number of Insured certain locations in New York State,Le.,Wrap-Up Policy) or Social Security Number 32-0580074 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier Town of SoutholdListed as he certificate Holder) Standard Security Life Insurance Company of New York 54375 Route 25 3b.Policy Number of Entity Listed in Box"l a" P.O. Box 1179 T20186-000 Southold, NY 11971 3c.Policy effective period 1/7/2018 to 11/18/2022 4. Policy provides the following benefits: Q A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as des c d above. Date Signed 11/19/2021 By rr� r (Signature of Insurance carrier's authoriz d representative or NYS Licensed Insurance Agent of that Insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law.It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200,Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4C or SB of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance canfers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. Additional Instructions for Form D13-120.1 By signing this form,the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in box"1 a"for disability and/or paid family leave benefits under the New York State Disability and Paid Family Leave Benefits Law.The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices my be sent by regular mail.)Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Disability and/or Paid Family Leave Benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or paid family leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of NYS Disability and/or Paid Family Leave Benefits Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Disability and Paid Family Leave Benefits Law. DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first, two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. ` (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carver is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first,two thousand eighteen,the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (10-17)Reverse AC�® DATE(MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 11/17/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER NAME: Joseph Price Joseph P.Price Jr Insurance Brokerage Inc, PHONE 631-509-4509 IFAXAfCNo Priceagy.com AD"RIESS: Joseph@pdceagy.com P.O.Box 171 INSURERS AFFORDING COVERAGE NAIC S Mt.Sinai, NY 11766 INSURER A: Southwest Marine&General Insurance Company 12294 INSURED INSURER B: New York Marine&General Insurance Comany 16608 NYSS LLC. INSURER C: Southwest Marine&General Insurance Company 12294 DBA NY STATE SOLAR INSURER D: 385 W JOHN STREET INSURER E: HICKSVILLE,NY 11801 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER MOM/ LDIDY EFF POLICY LIMITS LTR X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 GE TO CLAIMS-MADE �OCCUR PREM SES EaEoccurrence) $ 100,000 MED EXP(Any one person) $ 5,000 A PK202100018285 07/01/2021 07/01/2022 PERSONAL&ADV INJURY $ 1,000,000 GEN'LAGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY E PRO- LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Es accident ANY AUTO BODILY INJURY(Per person) $ B ALL OWNED rx SCHEDULED AU202100017053 07/01/2021 07/01/2022 BODILY INJURY(Per accident) $ AUTOS AUTOS X HIRED AUTOS NON-OWNED PROPERTY DAMAGE $ AUTOS Per accident UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 3,000,000 C X EXCESS LAB CLAIMS-MADE EX202100001570 07/01/2021 07/01/2022 AGGREGATE $ 3,000,000 DED X RETENTION$ 10,000 $ WORKERS COMPENSATION AND EMPLOYERS'LIABILITY Y/N STER ER ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ N/A E.L.EACH ACCIDENT $ OFFICERWEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Installation Floater PK202100018285 07/01/2021 07/01/2022 Occurrence $50,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Description:Solar energy contractor,including operations,maintenance,and panel installation.Electrical work and oversight of subcontractors. Evidence of insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of Southold Building Dept ACCORDANCE WITH THE POLICY PROVISIONS. 54375 Route 25 AUTHORIZED REPRESENTATIVE PO Box 1179 Southhold NY 11971 Joseph Price @ 1986-2014 ACOMOTORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD Labor,-Licensing tk Consumer Affairs HOME IMPROVEMENT LICENSE i Name REID T GARTON Business Name 's certifies that the arer is duly licensed NYSS LLC DBA_ the County of suffolk License Number:._ HI-62273 Rosalie Drago Issued: -06/03/2019 Commissioner Expires: 06/01/2023 j DIRECTORY OF PAGES SCOPE OF WORK PV-1 PROJECT SUMMARY THIS PROJECT INVOLVES THE INSTALLATION OF OF NF SOLAR PANELS.THE SOLAR PANELS WILL BE p�E PV-2 SITE PLAN RACKED USING A PREENGINEERED RACKING Gj� pLPH aq� 0 PV-3 ATTACHMENT PLAN SYSTEM.THE RACKED MODULES WILL BE • ELECTRICALLY CONNECTED WITH DC TO AC PV-4 ATTACHMENT DETAILS POWER INVERTERS AND INTERCONNECTED TO THE PV-5 3 LINE DIAGRAM LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE PV-6 SAFETY LABELS LOCAL UTILITY AND PERMITTING JURISDICTION. Odtl18'c x MODULE DATASHEET _ Z INVERTER DATASHEET W UiSSter4ngR0. �edso9 SYSTEM DETAILS a MOUNTING SYSTEM DATASHEET crcyu1,NY 11935 MOUNTING SYSTEM ENGINEERING LETTER NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM DESCRIPTION WITH NO BATTERY S1e�19� STORAGE PROJECT DETAILS ANNUAL PRODUCTION 6,581 KWH 0 ZONING RESIDENTIAL DC RATING OF SYSTEM 8,400 W x -A AC RATING OF SYSTEM 7,329 W it, € USE AND OCCUPANCY SINGLE FAMILY W SPVVR� (107AS)INTEGRATED IN CLASSIFICATION DWELLING INVERTER(S)pe�`� MODxE 8 x INVERTER TYPE MICRO INVERTER 8 PERMITTING AUTHORITY New. Ytrk © (z1) „ B UTILITY COMPANY PSEBG d1017337,7219i89 MODULE SUNPOWER-A400-BLK-G-AC oqi i 7 I! METER SERIAL NUMBER s NEC VERSION 2017 NEC(NFPA 70) INTERCONNECTION DETAILS 2020 NYS RESIDENTIAL Z r FIRE CODE LOAD SIDE AC O J CODE,IBC 2015. POINT OF CONNECTION CONNECTION PER NEC W M ARTICLE 705.12(D) Q rn CONTRACTOR INFORMATION 1 PLOT UTILITY SERVICE 120 1240 v 0 w W PV-I SCALE:NTS MAIN SERVICE PANEL OW W uJ c Z COMPANY NY STATE SOLAR WITOP-FED 200 A Z ELECTRICAL PANEL aS BUSBAR,200 A MAIN U) � 3 LICENCE NUMBER BREAKER L NASSAU COUNTY O W c 385 W JOHN ST UNIT 100, = C) 100,HICKSVILLE,NY SITE DETAILS Q A 11801 U ADDRESS U SUFFOLK COUNTY ASHRAE EXTREME LOW 6.80°F 3125 VETERANS THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF AB N I A MTAwwN MEMORIAL HWY,G, ASHRAE 2%HIGH 86.00°F 1 CMD 1 E.IM RONKONKOMA,NY 11779 PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE DATE Br M22 WITH APPLICABLE CODES AND REGULATIONS.THE DOCUMENT SHALL NOT BE RELIED UPON AS A CLIMATE DATA SOURCE TMY3 scAie. PHONE NUMBER 516418.2131 SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS.CONTRACTOR SHALL WIND SPEED 136 MPH NTS INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS AND NOTHING IN THIS CONTACT EMAIL info@nystatesolar.com DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM.CONTRACTOR IS WIND EXPOSURE B TIRE. ADDRESS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS.DIMENSIONS,AND DETAILS IN THIS CATEGORY PROJECT SUMMARY CONTRACTOR DOCUMENT. GROUND SNOW LOAD 30 PSF SIGNATURE P V 1 ROOF' GENERAL NOTES (I6)PV ARRAY LOCROINVERTERS EQUIPMENT LIKELY TO BE WORKED UPON NEI UNDER MO ES WHILE ENERGIZED SHALL BE INSTALLED IN 1 LOCATIONS THAT CLEARANCES PER NEC 1106MINIMUM WORKING y�P.��OFN��`O CONTRACTOR SHALL USE ONLY COMPONENTS 2 LISTED BY A NATIONALLY RECOGNIZED C "� TESTING LABORATORY FOR THE INTENDED USE Z ROOF 1 (/ (s)w ARRAY CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL RELATED EQUIPMENT, ? CABLES,ADDITIONAL CONDUITS,BOXES, +� 3 E1tl, RACEWAYS,AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND � 3510NP� OPERATIONAL PV SYSTEM THE SYSTEM SHALL COMPLY WITH NEC ARTICLE 690,ALL MANUFACTURERS LISTING 4 AND INSTALLATION INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S(AHJ) APPLICABLE CODES 0 WHERE DC PV SOURCE OR DC PV OUTPUT Y j' BOX W MONITORING CIRCUITS ARE RUN INSIDE THE BUILDING,THEY o� PV AC COMBINER SHALL BE CONTAINED IN METAL RACEWAYS, MAIN SERVICE PANEL TYPE MC METAL-CLAD CABLE,OR METAL - UTILITY METER 5 ENCLOSURES FROM THE POINT OF PENETRATION INTO THE BUILDING TO THE 8 M FIRST READILY ACCESSIBLE DISCONNECTING FRONT OF HOUSE MEANS,PER NEC 690.31(G) c FACING STREET, DRIVEWAY "s: 33? 1 SITE PLAN PV-2 SCALE:NTS zr O � w � in A4�"` R324.6 ROOF ACCESS AND PATHWAYS-ROOF ACCESS,PATHWAYS,AND SETBACK REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324.6.1 THROUGH P-324.6.2.11.ACCESS AND MINIMUMQ M v rn SPACING SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF,TO PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF,PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS,AND TO W W i PROVIDE EMERGENCY EGRESS FROM THE ROOF. O 1.- U 0)>_ LL LU Z Z EXCEPTIONS: z d p d 1.DETACHED,UNINHABITABLE STRUCTURES,INCLUDING BUT NOT LIMITED TO DETACHED GARAGES,PARKING SHADE STRUCTURES,CARPORTS,SOLAR TRELLISES AND SIMILAR STRUCTURES,SHALL NOT BE 0_ °iU m REQUIRED TO PROVIDE ROOF ACCESS. w Z W u�p 2.ROOF ACCESS,PATHWAYS AND SETBACKS NEED NOT BE PROVIDED WHERE THE BUILDING OFFICIAL HAS DETERMINED THAT ROOFTOP OPERATIONS WILL NOT BE EMPLOYED. ^ r 3.THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL(17-PERCENT SLOPE)OR LESS. 00 W U) U (NY)R324.6.1 PATHWAYS-NOT FEWER THAN TWO PATHWAYS,ON SEPARATE ROOF PLANES FROM LOWEST ROOF EDGE TO RIDE AND NOT LESS THAN 36 INCHES(914MM)WIDE,SHALL BE PROVIDED ON ALL Q BUILDINGS.NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF,FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A PATHWAY NOT LESS THAN 36 U U INCHES WIDE(914MM)SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY,ON AN ADJACENT ROOF PLANE,OR STRADDLING THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS MILAN ATANTA N CNKD E,IM VENT PIPES,CONDUIT,OR MECHANICAL EQUIPMENT.PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE LOCATED ALONG THE SAME PLANE AS THE TRUSS,RAFTER,OR OTHER SUCH FRAMING SYSTEM THAT DATE av21Im2: SUPPORTS THE PATHWAY. SCALE EXCEPTION:ACCESS PATHWAYS SHALL NOT BE REQUIRED ON ROOF SLOPES CONTAINING PHOTOVOLTAIC MODULES,PANELS,OR AN ARRAY WHERE THE OPPOSING OR ADJACENT ROOF SLOPE IS AN ACCESS NTS ROOF. TITLE. (NY)R324.6.2 SETBACK AT RIDGE-PHOTOVOLTAIC ARRAYS SHALL NOT BE LOCATED LESS THAN 18 INCHES(457MM)FROM A HORIZONTAL RIDGE. SITE PLAN PV-2 BUILDING REVIEW NOTE TOWN BUILDING PLANS EXAMINER HAS RECEIVED '(EpF ROOF AREA 1 THE ENCLOSED DOCUMENT FOR MINIMUM 11 12PITC RAFTER THE ACCEPTABLE THE TOWN AS SPE SUBMITTAL IED IN THE BUQUIREMENTS OFILDING AND/OR *��po�pH P4r�n`09 I t&12 PITCH 31'-0" C.SPACING RESIDENTIAL CODE OF THE STATE OF NEW YORK. 45)MOr -^ 151 MODULES [3M7 �18)ATTACHMENTS THIS REVIEW DOES NOT GUARANTEE COMPLIANCE TYPE n E.sNAPNRACK sPEEDSEx WITH THAT CODE.THAT RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE L OF THE NEW YORK STATE LICENSED DESIGN ■ PROFESSIONAL OF RECORD.THAT SEAL AND r SIGNATURE HAS BEEN INTERPRETED AS AN S[CNP� $ ATTESTATION THAT,TO THE BEST OF THE i r LICENSEES BELIEF AND INFORMATION THE WORK IN DOCUMENT IS: I -ACCURATE •CONFORMS NTH GOVERNING CODES JI�5'-0' APPLICABLE AT THE TIME OF THE SUBMISSION [7Ta J [84-] •CONFORMS WITH REASONABLE STANDARDS • OF PRACTICE AND WITH VIEW TO THE _ ROOF'TRUE:10'TILT:AREA SAFEGUARDING OF LIFE,HEALTH,PROPERTY ]44'TRU 4T112PITCH AND PUBLIC WELFARE IS THE RESPONSIBILITY � 1a-oc s ACIND OF THE LICENSEE o I (16)MODULES r 35' 6' (4T)ATTACHMENTS H n TYPE.SNAPMRACKSPEEDSEILL [426"[ KNEEN NOTE s • , i L^ 8 8 ■ ■ ■ ■ i n •AN 18"WIDE CLEARING(FREE OF SOLAR 'o - ■ ■ ■ �` I EQUIPMENT)SHALL BE PROVIDED ALONG AT > ■ • ■ : j - LEAST ONE SIDE OF THE ROOF RIDGE ON THE b 3 (TYPICAL SYSTEM ■ ■ ,':. SAME SIDE AS THE SOLAR EQUIPMENT OR ON i n 71 EACH OFF ACROSS ANOTHER SIDE OF THE RIDGE THAT DOES NOT ONLY rNA SHO_ HAVE SOLAR EQUIPMENT ON IT.SUFFICIENT FOR CLARITY 59'-6" [214, ACCESS PATHWAYS,ROOF ACCESS POINTS, Z J AND GROUND ACCESS AREAS SHALL BE O PROVIDED IN ACCORDANCE WITH THE 2020 W M NYS RESIDENTIAL CODE. Q m rn •ROOF SHALL HAVE NO MORE THAN A SINGLE 2 K I/ SPACINGSETYWENof W W ROMS AND COLUMNS LAYER OF ROOF COVERING IN ADDITION TO O �_ V m} THE SOLAR EQUIPMENT. LL W Z = Z •INSTALLATION OF SOLAR EQUIPMENT SHALL BE Z FLUSH-MOUNTED,PARALLEL TO AND NO MORE °d 2 6 THAN 6-INCHES ABOVE THE SURFACE OF THE W Z W ROOF. a�w c~1 0 •WEIGHT OF THE INSTALLED SYSTEM SHALL O W NOT EXCEED MORE THAN 5-PSF. H [j •ANY PLUMBING VENTS ARE NOT TO BE CUT OR :D Q COVERED FOR SOLAR EQUIPMENT U U INSTALLATION.ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A 'N A.TANTAKMN PLUMBING PERMIT AND INSPECTION. CHKD E.IM DATE 0121/2022 THIS PV SYSTEM HAS BEEN DESIGNED TO MEET SALE THE MINIMUM DESIGN STANDARDS FOR BUILDING NTS 1 ATTACHMENT PLAN AND OTHER STRUCTURES OF THE ASCE 7-10,2020 TITLE NYS RESIDENTIAL CODE. ATTACHMENT PLAN PV-3 SCALE:3/32"= 1'-0" PV-3 SNAPNRACK,ADJUSTABLE END CLAMP. SELECT TO MATCH MODULE HEIGHT - --'h-MODULE SPACING ROOF STRUCTURE SNAPNRACK,MID CLAMP. SELECT TO MATCH MODULE HEIGHT PV MODULE,TYP. RAFTER/SPACING. R1:2"x 12"1 1a"O.C. . Rz:z•x a"@ 16•O.C. Cp OF NFA --SNAPNRACK,ULTRA RAIL PV MODULE,TYP. PV MODULE FRAME,TYP. co - SNAPNRACK,UNIVERSAL END CLAMP. ACTUAL SPAN: R2:12'-3 R1:10'-0" • MODULE HEIGHT AGNOSTIC AND SNAPNRACK,ULTRA RAIL HIDDEN BENEATH MODULES 0 DETAIL A: DETAIL B: DETAIL C: SNAPNRACK,ULTRA RAIL SHEATHING: PLYWIDOD SNAPNRACK,ADJUSTABLE END CLAMP SNAPNRACK,MID CLAMP SNAPNRACK,UNIVERSAL END CLAMP k+ PV MODULE,TYP. COLLAR TIES: WA Oq � � q 641a� A TYPE/LAYERS: ARCH/1-LAYER �FFSSIONP�� i SNAPNRACK ULTRA RAIL •RAIL END OVERHANG' �— 'RAIL SPAN'DISTANCE BETWEEN -- DISTANCE FROM RAIL END CENTERS OF TWO ROOF ATTACHMENTS SNAPNRACK ROOF ATTACHMENT, TO OUTER ROOF ATTACHMENT CENTER. VARIES WITH ROOF TYPE J NOT TO EXCEED 34%OF ALLOWABLE SPAN F STRUCTURAL MEMBER ^ n u� SNAPNRACK,MID CLAMP. W x s SNAPNRACK,AD]USTABLE F o> END CLAMP.SELECT TO SELECT TO MATCH MODULE HEIGHT 'MODULE OVERHANG MATCH MODULE HEIGHT Q „m€ SNAPNRACK,ULTRA RAIL DISTANCE FROM RAIL SIDE 70 MODULE EDGE.. r PV MODULE TYP NOT TO EXCEED 25%OF MODULE LENGTH OR LO MODULE MANUFACTURER RECOMMENDATIONS $ } 8 L Zjm Oyu mfr€ b3: SNAPNRACK,ULTRA RAIL END CAP,OPTIONAL Z } O Lu ROOFING MATERIAL, Q :E M COMP SHINGLE SHOWN,TYP. ROOF SHEATHING AND UNDERLAYMENT MATERIAL,TYP. w W O F_ U c: STRUCTURAL MEMBER SNAPNRACK ROOF ATTACHMENT,VAIRES WITH LL LU W C Z EN WOODRAFTER SHOWN,TYP. ROOF TYPE IL•REFER TO SPECIFIC'ATTACHMENT DETAZ - FOR ATTACHMENT&WATERPROOFING DETAILS — .6 N w cn cn m W Z W Ln O O � LJ w � MID CLAMP ASSEMBLY F- _ / \r &12 AWG BARE 5/18'•'IB SS BOLT Cn F- COPPER / COPPER WIRE SS SPLIT LOCK VASHER Q (TORQUE TO FT-tBS) (J V / NOTE. SNAPNRACK 1.ALL HARDWARE IS INCLUDED FROM MANUFACTURER DRWN ATMrtAKARN 1 GROUND LUG 2.A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CHKC E SS BONDING PIN \ I `\ CONTINUOUS ROW OF MODULES DI1TE 0721no22 I 1 3.GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL I.GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR SCALE —� MODULE I CHANNEL NUT PERPENDICULAR TO RAIL i FRAME �` ' / �\ 5.ENSURE SPLIT LOCK WASHER 151NSTALLEDON TOP OF COPPER WIRE NTS RAIL lONDING RAIL ATTACHMENT DETAILS J� PINS CHANNEL NUT PV-47:1 OF 1 3 METER NUMBER:98593646 SIMPOAER ��/ 1 2 10 11 PvsuPERVI50R4 I.— ftAhvFA SIONP�F. FT�A.r"Ym.A.�n,:s, i . 1orO PMEL roou.Aa,uA:.teA.rwAa"nr Ar,n,n.,ww ""A sst .,.. 6 2 4 , Ul i'- 1 2 9 10 UJ Q - I F wYv...trWn AIM1•vv4rYAPF Atinvnr YCtuw.vAK�Y Z �$ — �fi �3. est SYSTEM DETAILS NEW GRID414TERACTIVE CONDUIT AND CONDUCTOR SCHEDULE p J PHOTOVOLTAIC SYSTEM DESCRIPTION H WITH NO BATTERY W M CONDUCTOR NUMBER OF CONDUIT RUN Q 2 STORAGE TAG CONDUCTOR TYPE CONDUIT TYPE 2 X v rn GAUGE CONDUCTORS SIZE LENGTH � W W pr DC RATING OF SYSTEM 8,400 W U F U rn} ENPHASE D-CABLE 12 2 WA N/A BO'-0" AC RATING OF SYSTEM 7,329 W 1 Z d W C Z RARE COPPER GND IN FREE AIR 6 1 N/A N/A 25'-0" — ,a a; 6j INVERTER(S) SPMR-M DD TAS)WTEGRATEDM 1n MODWAE ENPHASE"ABLE 12 2 W -0 A N/A BO' " W W W � INVERTER TYPE MICRO INVERTER 2 2 Z w I— t RARE COPPER GND IN FREE AIR 6 1NIA N/A 25-0" p W M U MODULE (27) SUN POW ER-A-400-BLK-G-AC 3 TlAMi2 10 2 LFMC 8 PVC 1" 50'-0" N U GENERAL NOTES 4 THV"2 10 2 LFMC&PVC 1" so'-0" 0 1, ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION 5 TM 2 10 4 PVC SCH.40 1" 30'-0" � F.A TNtARN wSTR(x; P EGC 10 2 PVC SCH.40 1" 30'-0" DATE �1�2 2. ALL PV EQUIPMENT SHALL LISTED BY RECOGNIZED TESTING LAB 3. WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION.BREAKER SHALL NOT READ LINE AND LOAD TMMN-2 12 3 PVC SCH.40 1" 1Q'-0" SCALE. 4. WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION,THE BREAKER SHALL BE INSTALLED AT THE 6 NTS OPPOSITE END OF THE BASS BAR OF THE MAIN BREAKER EGL 12 1 PVC SCH.40 1" 10'-0" S. WORK CLEARANCE AROUND ELECTRICAL.EQUIPMENT WALL BE MAINTAINED PER NEC 110.26(A)(1).110.26(A)(2). nTLE._ 110.269(AH3) TH%W2 6 3 PVC SCH.40 1" 20'-0" 6. ALL EXTERIOR CONDUITS.FITTINGS AND BOXES SHALL BE RAIN TIGH AND BE MIN.NEMA 3R RATED 7 3-LINE DIAGRAM 7. AC AND DC GROUNDING CONDUCTORS PER NEX ARTICLE 690.43(A)THRU(F)CONNECTED AS PER 690.45(A).69046 AND SIZED PER 250.112 GEC 6 1 N/A N/A 20'-0" B. PROVIDE EXPANSION JOINTS AND ANCHORING OF ALL CONDUIT RUNS AS PER NEC REQUIREMENTS CLASS 1-16 AWG.TWSTED PAIR P V 5 9. PROVIDE LABEL,PLACARD AT EXISTING UTILITY CONNECTION WITH'WARNING-CUSTOMER OWNED ELECTRICAL B INSTRUMENT CABLE 16 2 PVC SCH.40 1" 20'-0" GENERATION EQUIPMENT CONNECTED'WITH APPROPRIATE HAZARD AND OUTPUT RATTING OF PV SYSTEM DC RACEWAY PHOTOVOLTAIC SYSTEM LABELING NOTES O PHOTOVOLTAIC POWER SOURCE DISCONNECT _ ALL PLAQUES AND SIGNAGE REQUIRED BY 1 SEE NOTE NO.6 NEC ARTICLE AC SOLAR DISCONNECT,NEC 2017 NEC WILL BE INSTALLED AS REQUIRED SOF N�yY O 690.31(G)(3) © ARTICLE 690.14(C)(2) LABELS,WARNING(S)AND MARKING SHALL COMPLY WITH ANSI Z535.4,WHICH REQUIRES r TRANSITION BOX THAT DANGER,WARNING,AND CAUTION • , SIGNS USED THE STANDARD HEADER O O ELECTRIC SHOCK HAZARD 2 COLORS,HEADER TEXT,AND SAFETY ALERT ooxoEEQUIPPED WITH SYMBOL ON EACH LABEL.THE ANSI IBMWIS lON9Mranws ��THE LIME AND STANDARD REQUIRES A HEADING THAT IS AT LOAD SOESMAYBE EMI SHUTDOWN LEAST 50%TALLER THAN THE BODY TEXT,IN SIONr tin om PoTn ACCORDANCE WITH NEC ARTICLE 110.21(B)i `AT THE EACH DISCONNECTING SEE NOTE NO.7 NEC ARTICLE A PERMANENT PLAQUE OR DIRECTORY SHALL INVERTER O MEANS FOR PHOTOVOLTAIC O 690.56(C) BE INSTALLED PROVIDING THE LOCATION OF EQUIPMENT.NEC ARTICLE THE SERVICE DISCONNECTING MEANS AND o 690.17(4) 3 O THE PHOTOVOLTAIC SYSTEM Ct O ® DISCONNECTING MEANS IF NOT IN THE SAME <I LOCATION IN COMPLIANCE WITH NEC t WYERTER Ol1IPUT CONECTION 690.56(8) ? i 00 NOT RELOCATE THIS WHERE THE INVERTERS ARE REMOTELY u DISCONNECT SWITCH ELECTRIC SHOCK HAZARD 2IRCURRENTBEacE LOCATED FROM EACH OTHER,A DIRECTORY w j g 5 THE Tk CONDl1CTORS OF IN SHALL BE INSTALLED AT EACH DC ^r SOLAR BREAKER(MSP)NEC O © TwsvHor ROUNDED AM $ PHOTOVOLTAIC SYSTEM DISCONNECTING t- 9 ARE UNGROUNDED AM ARTICLE 705.12(D)(2)(3)(B) MEANS,AT EACH AC IS CONNECTING MEANS, � S MAY BE ENERGUED 4 _ _ AND AT THE MAIN SERVICE DISCONNECTING y MEANS SHOWING THE LOCATION OF ALL AC Z 8 OAT EACH DEVICE WHERE AND DC PHOTOVOLTAIC SYSTEM 6 3 ENERGIZED,UNGROUNDED DISCONNECTING MEANS IN THE BUILDING,IN S MAIN SERVICE PANEL CIRCUITS MAY BE EXPOSED DUAL POVVER SUPPLY ACCORDANCE WITH NEC 690.4(H) a'4 DURING SERVICE.NEC ARTICLE Tv ELECTRIC SYSTTEE�y �a ® © O ® O 690.35(F) THE MATERIALS USED FOR MARKING MUST s BE WEATHER RESISTANT,IN COMPLIANCE 9 ANY AC ELECTRICAL PANEL S WITH CBC 511.3.1.IT IS RECOMMENDED THAT m THAT IS FEED BY BOTH THE UL 969 BE USED AS STANDARD TO 1 O T • l UTILITY AND THE DETERMINE WEATHER RATING O J PHOTOVOLTAIC SYSTEM(MSP) LABEL(S)WITH MARKING"WARNING: H W u� NEC ARTICLE 705.12(D)(4) PHOTOVOLTAIC POWER SOURCE"SHALL BE Q -�0) LOCATED EVERY 10 FEET OF EACH DC W W DC DISCONNECT,NEC ARTICLE RACEWAY AND WITHIN ONE FOOT OF EVERY O 1.- U rn ® 690.53(FOR REFERENCE ONLY) • 6 TURN OR BEND AND WITHIN ONE FOOT LL LU W _ Z ABOVE AND BELOW ALL PENETRATIONS OF z ROOF/CEILING ASSEMBLIES,WALLS AND w N U 3 BARRIERS.THE LABEL SHALL HAVE 3/8"TALL W W tnO • LETTERS AND BE REFLECTIVE WITH WHITE ^ L • • TEXT ON A RED BACKGROUND 0 W r j LABEL(S)WITH MARKING"PHOTOVOLTAIC U) H CJ SYSTEM EQUIPPED WITH RAPID SHUTDOWN." U V B O SHALL BE LOCATED 7 POINT-OF-INTERCONNECTION OR AT MAIN Dawn aunTA N DISCONNECT,NEC ARTICLE ••,y SERVICE DISCONNECT.THE LABEL SHALL CHKD E.IM AC O AC DI (FOR REFERENCE ONLY) HAVE 318"TALL LETTERS AND BE REFLECTIVE DATE D�a1= WITH WHITE TEXT ON A RED BACKGROUND I SCALE. NTS POINT OF INTERCONNECTION OR AT MAIN TITLE. 1 O SERVICE DISCONNECT(MSP),NEC ARTICLE SAFETY LABELS 690.54(FOR REFERENCE ONLY) PV-6 AppROVED AS NOT s� OCCUPANCY DATE: '3 1 •�-�B.P.# C� OR USE IS UNLAWFUL FEE:ieBIJ•fh7 BY:` O NOTIFY BUILDING DEPARTMENT AT WITHOUT CERTIFICATE 765-1802 8 AM TO 4 PM FOR THE OF OCCUPANCY FOLLOWING INSPECTIONS: CY 1. FOUNDATION TWO REQUIRED. FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL'• CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR ,CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OP ;NEW YORK STATE & TOWN CODES �AS REQUIR AND CONDITIONS OF SOUTHOLD TOWN ZBA ! SOUTHOLD TOWN PLANNING BOARD acv=Lowmvm atm 'SOUTHOLD TOWN TRUSTEES N.Y.S.DEC RETAIN STORM WATP ER RUNOFF PURSUANT TO CNA OF THE TOWN CODE. Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2B P C M Ph:631-988-0000 Bohemia, NY 11716 I G c solar@pacificoengineering.com January 10,2022 i -- Town of Southold Building Department ® � � � � �p 54375 Route 25, P.O. Box 1179 �J Southold, NY 11971 '� •� 2022 FEB Subject: Solar Energy Installation for 0 Catherine&Peter Melly BUILDING DEPT. 1375 Sterling Rd TOWN OF SOUTHOLD Cutchogue, NY 11935 1 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section A B Mean roof height 26.0 ft 12.0 ft Pitch 44 degrees 19 degrees Roof rafter 2x12 2x8 Rafter spacing 16 inch on center 16 inch on center Reflected roof rafter span 8.9 ft 11.0 ft Table R802.4.1(1)max allowable 26.0 ft 18.5 ft The climactic and load information is below: CLIMACTIC AND Ground Wind Live Load, Point GEOGRAPHIC DESIGN Exposure Snow Speed,3 Pnetper pullout Fastener Type CRITERIA Category Load,Pg, sec gust, ASCE 7, load,Ib psf mph psf Roof Section A B 20 130 18 42 SS 5/16"dia lag bolt,4-1/2"length B 33 76 SS 5/16"dia lag bolt,4-1/2"length Weight Distribution ®F NZk�, array dead load 3.5 psf Q'` NPA � �- load per attachment 8.1 Ib The subject roof has 1 layer of shingles. Panels mounted flush to roof no higher than 6 inches above roof surface. Ralph Pacifico, PELU Professional Engineer 9 NYO IANS�'QQI.Q9�Y, 97 DIRECTORY OF PAGES SCOPE OF WORK PV- 1 PROJECT SUMMARY THIS PROJECT INVOLVES THE INSTALLATION OF OF NFp f{ PA SOLAR PANELS. THE SOLAR PANELS WILL BE �� C/,r O PV-2 SITE PLAN RACKED USING A PREENGINEERED RACKING PV-3 ATTACHMENT PLAN SYSTEM. THE RACKED MODULES WILL BE r ELECTRICALLY CONNECTED WITH DC TO AC n / � PV-4 ATTACHMENT DETAILS POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS t� a PV-5 3-LINE DIAGRAM CONSISTENT WITH THE RULES ENFORCED BY THE �A �6 8182 PV-6 SAFETY LABELS LOCAL UTILITY AND PERMITTING JURISDICTION. ofi 'SSIONP MODULE DATASHEET x � INVERTER DATASHEET ��a�� w 1375 Sterling Rd, �ecCsr9 Rd SYSTEM DETAILS a MOUNTING SYSTEM DATASHEET utchogue,NY 1 935 Q NEW GRID-INTERACTIVE MOUNTING SYSTEM ENGINEERING LETTER PHOTOVOLTAIC SYSTEM � DESCRIPTION WITH NO BATTERY Q �ec�ir9� STORAGE -j PROJECT DETAILS ANNUAL PRODUCTION 6,433 KWH � Eo =2 Z ZONING RESIDENTIAL 0 . DC RATING OF SYSTEM 8,400 W W r F- o> o AC RATING OF SYSTEM 6,195 W Q o USE AND OCCUPANCY SINGLE FAMILY I- CLASSIFICATION DWELLING S1QcINVERTER(S) (21) ENPHASE IQ7+(240 V) o Peconic X INVERTER TYPE MICRO INVERTER z g PERMITTING AUTHORITY New York a (21) HANWHA z >_ C, UTILITY COMPANY PSE&G 41.017337,-72.458469 MODULE Q.PEAK DUO BLK ML-G10+ 0 L z METER SERIAL NUMBER _� bt,pdatasso22 400 'a o > ( y NEC VERSION 2017 NEC (NFPA 70) a U z�i INTERCONNECTION DETAILS 2020 NYS RESIDENTIAL FIRE CODE LOAD SIDE AC O J CODE, IBC 2015. POINT OF CONNECTION CONNECTION PER NEC uj ARTICLE 705.12(D) Q c'') ri PLOT UTILITY SERVICE 120/240 V 0� UJ W CONTRACTOR INFORMATIONO I— U °' >- PV-1 SCALE: NTS MAIN SERVICE PANEL tL W Z �p W/TOP-FED 200 A Z 0- W L Z COMPANY NY STATE SOLAR (� E � V ELECTRICAL PANEL — - L,� BUSBAR, 200 A MAIN � .69 0 LICENCE NUMBER D 222 BREAKER Z � NASSAU COUNTY � � o W cy C) 0385 W JOHN ST UNIT 100, 100, HICKSVILLE, NY ;N j:)z.S DEPT U U 11801 TG�N ,�to;,THoL►) SITE DETAILS Q ADDRESS U SUFFOLK COUNTY ASHRAE EXTREME LOW 6.80° F 3125 VETERANS DRWN Q.ZENG MEMORIAL HWY, G, THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OFA ASHRAE 2% HIGH 86.00° F CHKD E.IM RONKONKOMA, NY 11779 PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE I DATE 01/07/2022 WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A CLIMATE DATA SOURCE TMY3 SCALE: PHONE NUMBER 516-418-2131 SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL WIND SPEED 136 MPH NTS INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS AND NOTHING IN THIS CONTACT EMAIL info@nystatesolar.com DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS WIND EXPOSUREB TITLE: ADDRESS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS,AND DETAILS IN THIS CATEGORY PROJECT SUMMARY CONTRACTOR DOCUMENT. GROUND SNOW LOAD 30 PSF SIGNATURE Pv_ 1 ROOF GENERAL NOTES (16)PV ARRAY MICRO INVERTERS EQUIPMENT LIKELY TO BE WORKED UPON G UNDER MODULES OF 1 WHILE ENERGIZED SHALL BE INSTALLED IN44 44 44 � PAC, LOCATIONS THAT SATISFY MINIMUM WORKING P qC CLEARANCES PER NEC 110.26 * ` /��oO�� 44 44 CONTRACTOR SHALL USE ONLY COMPONENTS 2 LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE ROOF 1 (5)PVARRAY CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL RELATED EQUIPMENT, 3 CABLES, ADDITIONAL CONDUITS, BOXES, �ESS10104 RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM THE SYSTEM SHALL COMPLY WITH NEC ARTICLE 690, ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AND THE 4 RELEVANT CODES AS SPECIFIED BY THE Q = AUTHORITY HAVING JURISDICTION'S (AHJ) o APPLICABLE CODES =i z WHERE DC PV SOURCE OR DC PV OUTPUT w Y T E BOX W MONITORING CIRCUITS ARE RUN INSIDE THE BUILDING, THEY o>Y PVAC COMBINER SHALL BE CONTAINED IN METAL RACEWAYS, U. MAIN SERVICE PANEL 5 TYPE MC METAL-CLAD CABLE, OR METAL >u (n Of UTILITY METER ENCLOSURES FROM THE POINT OF o 0 PENETRATION INTO THE BUILDING TO THE M FIRST READILY ACCESSIBLE DISCONNECTING o FRONT OF HOUSE MEANS, PER NEC 690.31(G) o:} FACING STREET, DRIVEWAY o NCH 1 SITE PLAN z PV-2 SCALE: NTS Z J O J Lu R324.6 ROOF ACCESS AND PATHWAYS- ROOF ACCESS, PATHWAYS,AND SETBACK REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324.6.1 THROUGH R.324.6.2.1.ACCESS AND MINIMUM Q rn SPACING SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, TO PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS,AND TOW W cr PROVIDE EMERGENCY EGRESS FROM THE ROOF. O I-Z U IL WZ Z EXCEPTIONS: Z W W 1. DETACHED, UNINHABITABLE STRUCTURES, INCLUDING BUT NOT LIMITED TO DETACHED GARAGES, PARKING SHADE STRUCTURES, CARPORTS, SOLAR TRELLISES AND SIMILAR STRUCTURES, SHALL NOT BE � °LJ 0 U REQUIRED TO PROVIDE ROOF ACCESS. w zLij Lo 2. ROOF ACCESS, PATHWAYS AND SETBACKS NEED NOT BE PROVIDED WHERE THE BUILDING OFFICIAL HAS DETERMINED THAT ROOFTOP OPERATIONS WILL NOT BE EMPLOYED. 3. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL(17-PERCENT SLOPE) OR LESS. 00 w (NY) R324.6.1 PATHWAYS-NOT FEWER THAN TWO PATHWAYS, ON SEPARATE ROOF PLANES FROM LOWEST ROOF EDGE TO RIDE AND NOT LESS THAN 36 INCHES (914MM)WIDE, SHALL BE PROVIDED ON ALL Q U BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, A PATHWAY NOT LESS THAN 36 U U INCHES WIDE (914MM) SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ZENG ADJACENT ROOF PLANES. PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS DRWN E.im. CHKD VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE LOCATED ALONG THE SAME PLANE AS THE TRUSS, RAFTER, OR OTHER SUCH FRAMING SYSTEM THAT DATE 01/07/2022 SUPPORTS THE PATHWAY. SCALE: EXCEPTION: ACCESS PATHWAYS SHALL NOT BE REQUIRED ON ROOF SLOPES CONTAINING PHOTOVOLTAIC MODULES, PANELS, OR AN ARRAY WHERE THE OPPOSING OR ADJACENT ROOF SLOPE IS AN ACCESS NTS ROOF. TITLE. (NY) R324.6.2 SETBACK AT RIDGE-PHOTOVOLTAIC ARRAYS SHALL NOT BE LOCATED LESS THAN 18 INCHES (457MM) FROM A HORIZONTAL RIDGE. SITE PLAN PV-2 BUILDING REVIEW NOTE TOWN BUILDING PLANS EXAMINER HAS RECEIVED ROOFAREAI THE ENCLOSED DOCUMENT FOR MINIMUM OF N� 164'TRUE;44'TILT; ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OFI' N PACs 11.6/12 PITCH 0� 2"x,2"RAFTER THE TOWN AS SPECIFIED IN THE BUILDING AND/OR 16"O.C.SPACING 3372" RESIDENTIAL CODE OF THE STATE OF NEW YORK. * �O (5)MODULES [372--0 (18)ATTACHMENTS THIS REVIEW DOES NOT GUARANTEE COMPLIANCE G TYPE:SNAPNRACK SPEEDSEAL _ G e /1 WITH THAT CODE. THAT RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE �� OF THE NEW YORK STATE LICENSED DESIGN _ ■ _ ■ — — ■� �� X- PROFESSIONAL OF RECORD. THAT SEAL AND ,0 2 `\ �, ` ■ oSIGNATURE HAS BEEN INTERPRETED AS AN i FFSSIO ATTESTATION THAT, TO THE BEST OF THE LICENSEES BELIEF AND INFORMATION THE WORK \\ T N I w IN DOCUMENT IS: u •ACCURATE •CONFORMS WITH GOVERNING CODES 5'-0' 6'-6- 6'-6-+184-] 7'-0' APPLICABLE AT THE TIME OF THE SUBMISSION � [60.] [78"7 [78.7 •CONFORMS WITH REASONABLE STANDARDS Q = OF PRACTICE AND WITH VIEW TO THE —� o ROOFAREA2 SAFEGUARDING OF LIFE, HEALTH, PROPERTY O E 344'TRUE:19'TILT; g 4.1/12 PITCH AND PUBLIC WELFARE IS THE RESPONSIBILITY o 2"x 8"RAFTER OF THE LICENSEE w Y E 16"O.C.SPACING x (16)MODULES35'-6" ~ o c (47)ATTACHMENTS 5 o Q N c TYPE:SNAPNRACK SPEEDSEAL [426-] 0� -- NOTE --- o ®■ ? o 0 ► z F_ _c —�i i •AN 18"WIDE CLEARING (FREE OF SOLAR o z ■ ■ • ■ EQUIPMENT) SHALL BE PROVIDED ALONG AT o --- -- ■ — ■ i— i ■ LEAST ONE SIDE OF THE ROOF RIDGE ON THE y SNAPNRACK SYSTEM i (TYPICAL RAIL ACROSS ■ SAME SIDE AS THE SOLAR EQUIPMENT OR ON Z m EACH ROW OF ARRAY) -- ---- ANOTHER SIDE OF THE RIDGE THAT DOES NOT ONLY TWO SHOWN HAVE SOLAR EQUIPMENT ON IT. SUFFICIENT FOR CLARITY 59'-s" ACCESS PATHWAYS, ROOF ACCESS POINTS, >_ [714-] AND GROUND ACCESS AREAS SHALL BE O J PROVIDED IN ACCORDANCE WITH THE 2020 W Io NYS RESIDENTIAL CODE. Q 2M •ROOF SHALL HAVE NO MORE THAN A SINGLE re, w 1/2'SPACING BETWEEN � Lu W ROWS AND COLUMNS LAYER OF ROOF COVERING IN ADDITION TO O I.-_ U } THE SOLAR EQUIPMENT. LL W Z z •INSTALLATION OF SOLAR EQUIPMENT SHALL BE Z 0- FLUSH-MOUNTED, PARALLEL TO AND NO MORE W W THAN 6-INCHES ABOVE THE SURFACE OF THELu Lo 0 ROOF. 2 � (r M U •WEIGHT OF THE INSTALLED SYSTEM SHALL O r- NOT EXCEED MORE THAN 5-PSF. _ j •ANY PLUMBING VENTS ARE NOT TO BE CUT OR D < COVERED FOR SOLAR EQUIPMENT U Q U INSTALLATION.ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A DRWN Q.ZENG PLUMBING PERMIT AND INSPECTION. cHKD E.IM DATE 01/07/2022 THIS PV SYSTEM HAS BEEN DESIGNED TO MEET SCALE: THE MINIMUM DESIGN STANDARDS FOR BUILDING NTS rl_"� ATTACHMENT PLAN AND OTHER STRUCTURES OF THE ASCE 7-10, 2020 TITLE. SCALE: 3/32" = 1'-0" NYS RESIDENTIAL CODE. ATTACHMENT PLAN PV-3 PV-:3 SNAPNRACK,ADJUSTABLE END CLAMP. SELECT TO MATCH MODULE HEIGHT 1/L"MODULE SPACING ROOF STRUCTURE SNAPNRACK,MID CLAMP. SELECT TO MATCHOW MODULE HEIGHT PV MODULE,TYP. R1: 2"x 12" @ 16" O.C. ( RAFTER/SPACING: R2: 2" x 8" @ 16" O.C. 0 SNAPNRACK,ULTRA RAIL r� PV MODULE,TYP. PV MODULE FRAME,TYP. SNAPNRACK,UNIVERSAL END CLAMP. ACTUAL SPAN: R1: 10'-0" MODULE HEIGHT AGNOSTIC AND R2: 12'-3" SNAPNRACK,ULTRA RAIL HIDDEN BENEATH MODULES i ® DETAIL A: DETAIL B: DETAIL C: SNAPNRACK,ULTRA RAIL SHEATHING: PLYWOOD SNAPNRACK, ADJUSTABLE END CLAMP SNAPNRACK, MID CLAMP SNAPNRACK, UNIVERSAL END CLAMP ��$ a� PV MODULE,TYP. COLLAR TIES: N/A 5t�� A 4 _ C TYPE/ LAYERS: ARCH / 1-LAYER SNAPNRACK,ULTRA RAIL "RAIL END OVERHANG" "RAIL SPAN"DISTANCE BETWEEN DISTANCE FROM RAIL END CENTERS OF TWO ROOF ATTACHMENTS SNAPNRACK ROOF ATTACHMENT, TO OUTER ROOF ATTACHMENT CENTER. VARIES WITH ROOF TYPE Q = NOT TO EXCEED 34%OF ALLOWABLE SPAN J c STRUCTURAL MEMBER O o rz E O " U m E 2 Q SNAPNRACK,ADJUSTABLE SNAPNRACK,MID CLAMP. W 0 END CLAMP.SELECT TO SELECT TO MATCH MODULE HEIGHT LL N 0 "MODULE OVERHANG" <( U. o MATCH MODULE HEIGHT SNAPNRACK,ULTRA RAIL DISTANCE FROM RAIL SIDE TO MODULE EDGE. w cr PV MODULE,TYP. NOT TO EXCEED 25%OF MODULE LENGTH OR co MODULE MANUFACTURER RECOMMENDATIONS S o �7 0_ L Y=o F c m Z } o L Z � 0 N N 3:x Q co U Z c)M SNAPNRACK,ULTRA RAIL END CAP,OPTIONAL Z J O w Ln ROOFING MATERIAL, Q M COMP SHINGLE SHOWN,TYP. < 75 _0 O') ROOF SHEATHING AND UNDERLAYMENT MATERIAL,TYP, w O U � } STRUCTURAL MEMBER, SNAPNRACK ROOF ATTACHMENT,VAIRES WITH LL_ w z Z WOODEN RAFTER SHOWN,TYP. ROOF TYPE.REFER TO SPECIFIC"ATTACHMENT DETAIL" Z n- w i FOR ATTACHMENT&WATERPROOFING DETAILS 06 � U) Q) w Z ti �O O � MLLJ A.- MID CLAMP ASSEMBLYTZU 6-12 AWG BARE 5/16"-18 SS BOLT I— COPPER WIRE SS SPLIT LOCK WASHER D Q _ — (TORQUE TO 16 FT-LBS) () V _ /�fli / \�\ NOTE. \ 1.ALL HARDWARE IS INCLUDED FROM MANUFACTURER SNAPNRACK 2.A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY DRWN Q2ENG / _ \ GROUND LUG CONTINUOUS ROW OF MODULES CHKD E.IM — DATE 01/07/2022 SS BONDING PIN 1 I /i \ 3.GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL 4.GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR SCALE: —�——— MODULE I CHANNEL NUT PERPENDICULAR TO RAIL FRAME \ / 5.ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE NTS I I RAIL TITLE: SS BONDING RAIL ATTACHMENT DETAILS � PINS CHANNEL NUT PV-4-1 METER NUMBER:98593646 .(�' OF ROOF ATTIC � TO UTILITY PAC" y 1 3 O ROOF MOUNTED SOLAR DECK O UTILITY METER m 1 2 12 13 I -UI 0 —— ----- - ----- I EXTERIOR WALL I j'y 2 I 5 IQ COMBINER PANEL ' FFgsIot PA � ENPHASE ENVOY � I I 10Ar2P I STRING OF I I I MSP NOTE (13)Q.PEAK DUO BLK ML-G10+ ' 20A/2p I THIS MAIN DISTRIBUTION 400 MODULES MOON PANEL HAS A 200 AMP I MAIN RATED BUS WITH 200 AMP (13)ENPHASE 07-72-2 US —— I J -------- - ------- ----y I MAIN BREAKER MICRO INVERTER 2pgl2P I I L0 IN PARALLEL EGO ATTACHED I LOADS 200 A BUS z 120%=240 A TO RAIL I 240 A-200 A MAIN=40 At - ,{ r_____ _ _____________, I < = ROOF MOUNTED I 40p I THE MAXIMUM BACK FEED rn 13 MODULES/STRING x 1.21 AlMODULE=15.73 AMP LOAD/STRING SOLAR DECK I I CIRCUIT BREAKER SIZE IS J `p n 15.73 AMP x 1.25 CONT DUTY=19.66 AMP(WIRE AMPACITY MIN.) I 40 AMP PER NEC 2017 C E SECTION 705.12(D)(2)(3)(b) 0 Z I 'N­L, N Lz L' CONNECTION WITH c �p 1 2 7 $ ----- -- EGC/GEC I LOAD SIDE PER NEC 2017 LJ Y o r SECTION 230.82(6) J x I 1— 0> o 6 _1_GROUND ROD ? o 2 4 (!) o o ROOF ATTIC � O STRING OF I -- (8)Q.PEAK DUO BLK ML-G10+ I F- - 400 MODULES Z to = (8)ENPHASE IQ7+-72-2-US —J > MICRO INVERTER — L)s Z IN PARALLEL EGC AT TO RAIL w n 8 MODULESlSTRING x 1.21 A/MODULE=9.68 AMP LOAD/STRING Z 9.68 AMP z 1.25 CONT DUTY=12.10 AMP(WIRE AMPACITY MIN.) Z J O W M Q rn 0� wW CONDUIT AND CONDUCTOR SCHEDULE 0 L w Z �' z CONDUCTOR NUMBER OF CONDUIT RUN GENERAL NOTES Z � p TAG CONDUCTOR TYPE CONDUIT TYPE ci� wc GAUGE CONDUCTORS SIZE LENGTH ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S LLI Ill O 1 INSTALLATION INSTRUCTIONS z )` = 1 ENPHASE Q-CABLE 12 2 N/A N/A 1001-01, O (') U 2 ALL PV EQUIPMENT SHALL LISTED BY RECOGNIZED TESTING LAB BARE COPPER GND IN FREE6 1 N/A N/A 25'-0" AIR 3 READ LINE AND LOAD :D Q WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION.BREAKER SHALL NOT C/) U 2 ENPHASE Q-CABLE 12 2 N/A N/A 70'-0" WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION,THE BREAKER SHALL BE BARE COPPER GND IN FREE 6 1 N/A N/A 25'-0" 4 INSTALLED AT THE OPPOSITE END OF THE BASS BAR OF THE MAIN BREAKER DRWN Q.ZENG AIR WORK CLEARANCE AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), CHKD E.IM 3 THWN-2 10 2 LFMC & PVC 1" 5 110.26(A)(2),110.269(A)(3)70'-0" DATE 01/07i2022 ALL EXTERIOR CONDUITS,FITTINGS AND BOXES SHALL BE RAIN TIGH AND BE MIN.NEMA 3R SCALE: 4 THWN-2 10 2 LFMC & PVC 1" 70'-0" 6 RATED NTS AC AND DC GROUNDING CONDUCTORS PER NEX ARTICLE 690.43(A)THRU(F)CONNECTED AS PER rJ THWN-2 10 4 PVC SCH. 40 ill 30'-0" 7 690.45(A),690.46 AND SIZED PER 250.112 TITLE: EGC 10 2 PVC SCH. 40 1" 30'-0" $ PROVIDE EXPANSION JOINTS AND ANCHORING OF ALL CONDUIT RUNS AS PER NEC 3-LINE DIAGRAM REQUIREMENTS 6 THWN-2 6 3 PVC SCH. 40 ill 20'-0" PROVIDE LABEL,PLACARD AT EXISTING UTILITY CONNECTION WITH"WARNING-CUSTOMER GEC 6 1 N/A N/A 20'-0" 9 OU ELECTRICAL ING OF PV SYSAE�ON EQUIPMENT CONNECTED"1MTH APPROPRIATE HAZARD AND PV=-5 _ DC RACEWAYS PHOTOVOLTAIC SYSTEM LABELING NOTES PHOTOVOLTAIC POWER SOURCEDISCONNECT OALL PLAQUES AND SIGNAGE REQUIRED BYOf 1 SEE NOTE N0. 6 NEC ARTICLE AC SOLAR DISCONNECT, NEC 2017 NEC WILL BE INSTALLED AS REQUIRED �'t `'' O 690.31(G)(3) © ARTICLE 690.14(C)(2) LABELS, WARNING(S)AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES TRANSITION BOX rTHAT DANGER, WARNING, AND CAUTION Fj AWARNIN PHOTOVOLTAIC SIGNS USED THE STANDARD HEADER I ELECTRIC SHOCK HAZARD 2 COLORS, HEADER TEXT, AND SAFETY ALERT O O DO NOT TOUCH TERMINALSIT H SYMBOL ON EACH LABEL. THE ANSI TERMINALS ON BOTH THE LINE AND STANDARD REQUIRES A HEADING THAT IS AT LOAD SIDES MAY BE ENERGIZED RAPID LEAST 50%TALLER THAN THE BODY TEXT, IN Ssto IN THE OPEN POSITION ACCORDANCE WITH NEC ARTICLE 110.21(B) i AT THE EACH DISCONNECTING SEE NOTE NO. 7 NEC ARTICLE A PERMANENT PLAQUE OR DIRECTORY SHALL INVERTER O MEANS FOR PHOTOVOLTAIC O 690.56(C) BE INSTALLED PROVIDING THE LOCATION OF EQUIPMENT. NEC ARTICLE THE SERVICE DISCONNECTING MEANS AND O O ® 690.17(4) 3 THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME ELWARNING LOCATION IN COMPLIANCE WITH NEC o INVERTER OUTPUT CONNECTION 690.56(B) z d ��z DO NOT RELOCATE THIS0 . C.E. WHERE THE INVERTERS ARE REMOTELY E OVERCURRENT DEVICE Y ; a DISCONNECT SWITCH ELECTRIC SHOCK HAZARD �- {" LOCATED FROM EACH OTHER, A DIRECTORY 0 0 THE DC CONDUCTORS OF IN SHALL BE INSTALLED AT EACH DC m THIS PHOTOVOLTAIC SYSTEM Q SOLAR BREAKER (MSP) NEC PHOTOVOLTAIC SYSTEM DISCONNECTING O © ARE UNGROUNDED AND V ARTICLE 705.12(D)(2)(3)(B) 4 MEANS, AT EACH AC IS CONNECTING MEANS, > o MAY BE ENERGIZED AND AT THE MAIN SERVICE DISCONNECTING - - o MEANS SHOWING THE LOCATION OF ALL AC O AT EACH DEVICE WHERE ' AND DC PHOTOVOLTAIC SYSTEM z 3 ENERGIZED, UNGROUNDED OW DISCONNECTING MEANS IN THE BUILDING, IN o MAIN SERVICE PANEL CIRCUITS MAY BE EXPOSED DUAL POWER SUPPLY ACCORDANCE WITH NEC 690.4(H) 0 DURING SERVICE. NEC ARTICLE SOURCES:UTILITY GWD AND ; y 690.35 F PV SOLAR ELECTRIC SYSTEM THE MATERIALS USED FOR MARKING MUST Z G O O © O ® O BE WEATHER RESISTANT, IN COMPLIANCE POWER 9 ANY AC ELECTRICAL PANEL 5 WITH CBC 511.3.1. IT IS RECOMMENDED THAT DC • • • • SOURCE THAT IS FEED BY BOTH THE UL 969 BE USED AS STANDARD TO O RATED MPP VOLTAGE z 367 VDC UTILITY AND THE DETERMINE WEATHER RATING O J MAX • PHOTOVOLTAIC SYSTEM (MSP) LABEL(S) WITH MARKING "WARNING: W coLo SHORT CURRENT •:' • NEC ARTICLE 705.12(D)(4) PHOTOVOLTAIC POWER SOURCE" SHALL BE Q LOCATED EVERY 10 FEET OF EACH DC cr_ W W ® DC DISCONNECT, NEC ARTICLE RACEWAY AND WITHIN ONE FOOT OF EVERY O I- U } 690.53 (FOR REFERENCE ONLY) . 6 TURN OR BEND AND WITHIN ONE FOOT LL W Z ABOVE AND BELOW ALL PENETRATIONS OF Z POWER • • • • ROOF/CEILING ASSEMBLIES, WALLS AND � w U) U) :3SUPPLIE• '• • • •BARRIERS. THE LABEL SHALL HAVE 3/8"TALL W o i WITH • • • • • LETTERS AND BE REFLECTIVE WITH WHITE :E - co C)TEXT ON A RED BACKGROUND ILLI WITH MARKING "PHOTOVOLTAIC U Tj mill SYSTEM EQUIPPED WITH RAPID SHUTDOWN." U SHALL BE LOCATED �•.. 7 POINT-OF-INTERCONNECTION OR AT MAIN DRWN Q.ZENG AC DISCONNECT, NEC ARTICLEO I SERVICE DISCONNECT. THE LABEL SHALL CHKD E.IM 690.54 (FOR REFERENCE ONLY) •� """ HAVE 3/8"TALL LETTERS AND BE REFLECTIVE DATE 01/07/2022 ���N� WITH WHITE TEXT ON A RED BACKGROUND SCALE: POINT OF INTERCONNECTION OR AT MAIN NTS 1 O SERVICE DISCONNECT(MSP), NEC ARTICLE TITLE. 690.54 (FOR REFERENCE ONLY) SAFETY LABELS PV-6 Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 213 C T Ph:631-988-0000 Bohemia, NY 11716 I G c solar@pacificoengineering.com March 21,2022 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Catherine&Peter Melly 1375 Sterling Rd Cutchogue, NY 11935 1 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted' system.The units are to be installed in accordance with.the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section A B Mean roof height 26.0 ft 12.0 ft Pitch. 44 degrees 19 degrees Roof rafter 2x12 2x8 Rafter spacing 16 inch on center 16 inch on center Reflected roof rafter span 8.9 ft 11.0 ft Table R802.4.1(1)max allowable 26.0 ft 18.5 ft The climactic and load information is below: CLIMACTIC AND Ground Wind Live Load, Point GEOGRAPHIC DESIGN Exposure Snow Speed,3 Pnet per pullout Fastener Type Category. Load,Pg, sec gust, ASCE 7, CRITERIA psf mph psf load,Ib Roof Section A B 20 130 18 41 SS 5/16"dia lag bolt,4-1/2"length B. 33 74 SS 5/16"dia lag bolt,4-112"length Weight Distribution array dead load 3.5 psf 7�® q%A PACK load per attachment 7.8 Ib C�j��`�X' The As subject roof has 1 layer of shingles. 1 Y 9f'' Panels mounted flush to roof no higher than 6 inches above roof surface. r- �,1�V) Ralph Pacifico, PE Professional Engineer ��® 61 es a al Y NY 066 9 297 JUL 18 209BUILDING DEPT DO l� TOWN OF SOUTN611-D DIRECTORY OF PAGES SCOPE OF WORK PV- 1 PROJECT SUMMARY THIS PROJECT INVOLVES THE INSTALLATION OF -Y ��`wl�� SOLAR PANELS. THE SOLAR PANELS WILL BE ,�l PV 2 SITE PLAN � A RACKED USING A PREENGINEERED RACKING r �� ACr" Q PV- 3 ATTACHMENT PLAN SYSTEM. THE RACKED MODULES WILL BE Q�� �Do� � PV-4 ATTACHMENT DETAILS ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE + �..I PV- 5 3-LINE DIAGRAM LOCAL UTILITY USING MEANS AND METHODS h , CONSISTENT WITH THE RULES ENFORCED BY THE : PV-6 SAFETY LABELS LOCAL UTILITY AND PERMITTING JURISDICTION. MODULE DATASHEET '� �S5ia �° w� X _= Z INVERTER DATASHEET l a` w 1375 Sterling Rd, Stzt�h�9R� SYSTEM DETAILS a MOUNTING SYSTEM DATASHEET utchogue,NY 11435 0- Q MOUNTING SYSTEM ENGINEERING LETTER NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM C, DESCRIPTION : S`�dtngRd WITH NO BATTERY in 01 STORAGE PROJECT DETAILS ANNUAL PRODUCTION 6,581 KWHZ'' L D Z 0a ZONING RESIDENTIAL DC RATING OF SYSTEM 8,400 W AL J o 0 AC RATING OF SYSTEM 7,329 W > USE AND OCCUPANCY SINGLE FAMILY SPWR-A4(IQ 7AS)INTEGRATED IN } CLASSIFICATION DWELLING S`e�`�9 INVERTER(S) MODULE G' o Peconic x INVERTER TYPE MICRO INVERTER > o PERMITTING AUTHORITY New Yak `' > UTILITY COMPANY PSE&G MODULE } 41.017337,•72.45&409 (21) SUNPOWER-A-400-BLK-G-AC ° r z METER SERIAL NUMBER Map da:a.^s2c22 ° a3= � N NEC VERSION 2017 NEC (NFPA 70) z m x ZM= INTERCONNECTION DETAILS FIRE CODE 2020 NYS RESIDENTIAL CODE, IBC 2015. LOAD SIDE AC O J POINT OF CONNECTION CONNECTION PER NECW M ARTICLE 705.12(D) Q rn 1 PLOT UTILITY SERVICE 120/240 V W Wry CONTRACTOR INFORMATION p I— v 0) >- PV-1 SCALE: NTS MAIN SERVICE PANEL LL W Z LLJ COMPANY NY STATE SOLAR ELECTRICAL PANEL W/TOP-FED 200 A Z 0 4 BUSBAR, 200 A MAIN c/) C/) LICENCE NUMBER BREAKER WZ W Lo � NASSAU COUNTY O UJ co 0 385 W JOHN ST UNIT 100 1— 100, HICKSVILLE, NYU)SITE DETAILS Q U 11801 C� ADDRESS SUFFOLK COUNTY ASHRAE EXTREME LOW 6.80° F U 3125 VETERANS THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF Aa DRWN A.TANTAKARN MEMORIAL HWY, G, PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE ASHRAE 2/o HIGH 86.00° F E.IPA RONKONKOMA, NY 11779 DATE os;zvzozz WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A CLIMATE DATA SOURCE TMY3 SCALE. PHONE NUMBER 516-418-2131 SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL WIND SPEED 136 MPH NTS INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS AND NOTHING IN THIS CONTACT EMAIL info@nystatesolar.com DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS WIND EXPOSURE TITLE. ADDRESS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS CATEGORY B PROJECT SUMMARY CONTRACTOR DOCUMENT. SIGNATURE GROUND SNOW LOAD 30 PSF Pv_ � ROOF 2 GENERAL NOTES (16)PV ARRAY MICRO INVERTERS EQUIPMENT LIKELY TO BE WORKED UPON UNDER MODULES WHILE ENERGIZED SHALL BE INSTALLED IN 1 LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26 �1�� C`�ts c �aiy'1�` CONTRACTOR SHALL USE ONLY COMPONENTS 2 LISTED BY A NATIONALLY RECOGNIZED 1v TESTING LABORATORY FOR THE INTENDED USE ROOF 1 (5)PV ARRAY CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL RELATED EQUIPMENT, %` ` • VENTILATION-18" U CABLES, ADDITIONAL CONDUITS. BOXES, ' ' 3 RACEWAYS. AND OTHER ACCESSORIESVEN NECESSARY FOR A COMPLETE AND 'r <° Z OPERATIONAL PV SYSTEM THE SYSTEM SHALL COMPLY WITH NEC �z� k ARTICLE 690, ALL MANUFACTURERS LISTING 4 AND INSTALLATION INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED BY THE `r = AUTHORITY HAVING JURISDICTION'S (AHJ) } APPLICABLE CODES t z 2 Z WHERE DC PV SOURCE OR DC PV OUTPUT o o CIRCUITS ARE RUN INSIDE THE BUILDING, THEY J 0 BOX W MONITORING N x PV AC COMBINER SHALL BE CONTAINED IN METAL RACEWAYS. < N 1. MAIN SERVICE PANEL TYPE MC METAL-CLAD CABLE.. OR METAL F- UTILITY METER 5 ENCLOSURES FROM THE POINT OF 0 PENETRATION INTO THE BUILDING TO THE a M FIRST READILY ACCESSIBLE DISCONNECTING G r s FRONT OF HOUSE MEANS, PER NEC 690.31(G) M } FACING STREET, DRIVEWAY "=Z mod 1 SITE PLAN z m PV-2 SCALE- NTS Z J O W R324.6 ROOF ACCESS AND PATHWAYS - ROOF ACCESS, PATHWAYS, AND SETBACK REQUIREMENTS SHALL BE PROVIDED iN ACCORDANCE WITH SECTIONS R324.6.1 THROUGH R.324.6.2.1. ACCESS AND MINIMUM Q rn SPACING SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, TO PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO w W W PROVIDE EMERGENCY EGRESS FROM THE ROOF. O I_- U 0) } LL WZ cZ EXCEPTIONS: Z W W 1. DETACHED, UNINHABITABLE STRUCTURES, INCLUDING BUT NOT LIMITED TO DETACHED GARAGES, PARKING SHADE STRUCTURES, CARPORTS. SOLAR TRELLISES AND SIMILAR STRUCTURES, SHALL NOT BE (z0 C/) REQUIRED TO PROVIDE ROOF ACCESS. W LLJ z O 2. ROOF ACCESS, PATHWAYS AND SETBACKS NEED NOT BE PROVIDED WHERE THE BUILDING OFFICIAL HAS DETERMINED THAT ROOFTOP OPERATIONS WILL NOT BE EMPLOYED. 3. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (17-PERCENT SLOPE) OR LESS, 0 W 2 (NY) R324.6.1 PATHWAYS - NOT FEWER THAN TWO PATHWAYS, ON SEPARATE ROOF PLANES FROM LOWEST ROOF EDGE TO RIDE AND NOT LESS THAN 36 INCHES (914MM) WIDE, SHALL BE PROVIDED ON ALL H U BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, A PATHWAY NOT LESS THAN 36 U U INCHES WIDE (914MM) SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF, PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS DRWN CHKD E.TANTAKARN E.IPA VENT PIPES. CONDUIT, OR MECHANICAL EQUIPMENT. PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE LOCATED ALONG THE SAME PLANE AS THE TRUSS, RAFTER, OR OTHER SUCH FRAMING SYSTEM THAT DATE 03;21/2022 SUPPORTS THE PATHWAY. SCALE. _ EXCEPTION. ACCESS PATHWAYS SHALL NOT BE REQUIRED ON ROOF SLOPES CONTAINING PHOTOVOLTAIC MODULES, PANELS, OR AN ARRAY WHERE THE OPPOSING OR ADJACENT ROOF SLOPE ]SAN ACCESS NTS ROOF. TITLE: (NY) R324.6.2 SETBACK AT RIDGE- PHOTOVOLTAIC ARRAYS SHALL NOT BE LOCATED LESS THAN 18 INCHES (457MM) FROM A HORIZONTAL RIDGE. SITE PLAN Pv-2 BUILDING REVIEW NOTE TOWN BUILDING PLANS EXAMINER HAS RECEIVED P F= ,� � THE ENCLOSED DOCUMENT FOR MINIMUM "fi .� J f� ROOF AREA 1 r�l 111 164'TRUE,44'TILT: ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF C�j E,�,,° ,q 11.6/12 PITCH 2"x 12"RAFTER THE TOWN AS SPECIFIED IN THE BUILDING AND/OR 16' [372'1 O.C.SPACING RESIDENTIAL CODE OF THE STATE OF NEW YORK. 4' 1 (5)MODULES (18)ATTACHMENTS THIS REVIEW DOES NOT GUARANTEE COMPLIANCE ;I } TYPE.SNAPNRACK SPEEDSEAL WITH THAT CODE. THAT RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE r OF THE NEW YORK STATE LICENSED DESIGN 3 • i PROFESSIONAL OF RECORD.THAT SEAL AND , SIGNATURE HAS BEEN INTERPRETED AS AN FL �►v., °0 ATTESTATION THAT, TO THE BEST OF THE jRoomo r LICENSEES BELIEF AND INFORMATION THE WORK i m IN DOCUMENT I& `O u •ACCURATE •CONFORMS WITH GOVERNING CODES 5'-0" 6'-6" 6'-6" 7'-0' APPLICABLE AT THE TIME OF THE SUBMISSION [60"] [781 [781 [84'1� *CONFORMS WITH REASONABLE STANDARDS <: _ OF PRACTICE AND WITH VIEW TO THE ROOF AREA 2 �; ~ E 344'TRUE:19'TILT. SAFEGUARDING OF LIFE, HEALTH, PROPERTY Z'2 Y 4.1/12 PITCH AND PUBLIC WELFARE IS THE RESPONSIBILITY 1'` 0 .� 2"x O.C.RAFTER OF THE LICENSEE l:. Y a 16" . SPACING 0 ( > 35'-6" (47)ATTACHMENTS d ca <, o TYPE:SNAPNRACK SPEEDSEAL [426'7 �. w"tY NOTE ■ i I �i � l 5 ( ~Zm i !, ° ; •AN 18" WIDE CLEARING (FREE OF SOLAR o t� ■ /` EQUIPMENT) SHALL BE PROVIDED ALONG AT o y --i ■ ■ ■ LEAST ONE SIDE OF THE ROOF RIDGE ON THE N 3 ' SNAPNRACK SYSTEM '' ■ 1 �• ■ a m (TYPICAL RAIL ACROSS _ _ __ ___ ■ SAME SIDE AS THE SOLAR EQUIPMENT OR ON Z _ EACH ROW OF ARRAY) — -- — ANOTHER SIDE OF THE RIDGE THAT DOES NOT ONLY TWO SHOWN HAVE SOLAR EQUIPMENT ON IT. SUFFICIENT FOR CLARITY 59'-6" [714 ACCESS PATHWAYS; ROOF ACCESS POINTS, Z >_ AND GROUND ACCESS AREAS SHALL BE O J PROVIDED IN ACCORDANCE WITH THE 2020 W Ln NYS RESIDENTIAL CODE. Q M •ROOF SHALL HAVE NO MORE THAN A SINGLE 0 1/2"SPACING BETWEEN LAYER OF ROOF COVERING IN ADDITION TO W W ROWS AND COLUMNS O I— U 0) >_ THE SOLAR EQUIPMENT. H W z Z •INSTALLATION OF SOLAR EQUIPMENT SHALL BE Z 0- W L FLUSH-MOUNTED, PARALLEL TO AND NO MORE W 0 THAN 6-INCHES ABOVE THE SURFACE OF THE W Z W Lo O ROOF. (r M U • WEIGHT OF THE INSTALLED SYSTEM SHALL O W NOT EXCEED MORE THAN 5-PSF. � 7- U •ANY PLUMBING VENTS ARE NOT TO BE CUT OR D Q COVERED FOR SOLAR EQUIPMENT U U INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A DRWN A.TANTAKARN PLUMBING PERMIT AND INSPECTION. DATE E 03/2112022 DATE THIS PV SYSTEM HAS BEEN DESIGNED TO MEET _.. SCALE: THE MINIMUM DESIGN STANDARDS FOR BUILDING _ NTS 1 ATTACHMENT PLAN AND OTHER STRUCTURES OF THE ASCE 7-10, 2020 rin_E — NYS RESIDENTIAL CODE. ��-3SCALE: 3/32" = V-0" ATTACHMENT PLAN Pv___3 �SNAPNRACK,ADJUSTABLE END CLAMP. SELECT TO MATCH MODULE HEIGHT 1/2" MODULE SPACING ROOF STRUCTURE SNAPNRACK,MID CLAMP. nn SELECT TO MATCH @ MODULE HEIGHT PV MODULE,TYP. R1: 2" X 12" 16" O.C. RAFTER/SPACING: R2: 2" x 8" @ 16" O.C. -� t L � ✓' �f C ; SNAPNRACK,ULTRA RAILPV MODULE FRAME,TYP. PV MODULE,TYP. a :. k SNAPNRACK,UNIVERSAL END CLAMP. R1: 10'-0" f I- ? � MODULE HEIGHT AGNOSTIC AND ACTUAL SPAN: R2: 12'-3" 11 C" .5 e SNAPNRACK, ULTRA RAIL HIDDEN BENEATH MODULES ® DETAIL A: DETAIL B: DETAIL C: SNAPNRACK,ULTRA RAIL SHEATHING: PLYWOOD SNAPNRACK, ADJUSTABLE END CLAMP SNAPNRACK, MID CLAMP SNAPNRACK, UNIVERSAL END CLAMP PV MODULE,TYP. COLLAR TIES: N/A �1LBN Q _ TYPE/LAYERS: ARCH ! 1-LAYER SNAPNRACK,ULTRA RAIL - -- - "RAIL END OVERHANG" —. � RAIL SPAN"DISTANCE BETWEEN ---- J, DISTANCE FROM RAIL END CENTERS OF TWO ROOF ATTACHMENTS SNAPNRACK ROOF ATTACHMENT, TO OUTER ROOF ATTACHMENT CENTER. VARIES WITH ROOF TYPE Q = NOT TO EXCEED 34%OF ALLOWABLE SPANJ T STRUCTURAL MEMBER O Y `o_ rE z � > � z O 6 E SNAPNRACK,ADJUSTABLE SNAPNRACK, MID CLAMP. 41 W o c END CLAMP.SELECT TO SELECT TO MATCH MODULE HEIGHT LL c x "MODULE OVERHANG" c. MATCH MODULE HEIGHT SNAPNRACK,ULTRA RAIL, DISTANCE FROM RAIL SIDE TO MODULE EDGE, F PV MODULE,TYP. NOT TO EXCEED 25%OF MODULE LENGTH OR G o MODULE MANUFACTURER RECOMMENDATIONS 0 0 __-- Z m O } j Z -- --_ SNAPNRACK,ULTRA RAIL END CAP,OPTIONAL Z O W L0 ROOFING MATERIAL, Q n COMP SHINGLE SHOWN,TYP. 70 ROOF SHEATHING AND L W W UNDERLAYMENT MATERIAL,TYP. O I­_ U } STRUCTURAL MEMBER, SNAPNRACK ROOF ATTACHMENT,VAIRES WITH LL � W @ Z WOODEN RAFTER SHOWN,TYP. ROOF TYPE. REFER TO SPECIFIC"ATTACHMENT DETAIL" Z FOR ATTACHMENT&WATERPROOFING DETAILS 06 � C- � W Z w L0 O r- = O co w i- MID CLAMP ASSEMBLY ~ _ / 6-12 AWG BARE 5/16"-18 SS BOLT U / COPPER WIRE SS SPLIT LOCK WASHER Q 1 - (TORQUE TO 16 FT-LBS) (� C� / / NOTE: \� 1.ALL HARDWARE IS INCLUDED FROM MANUFACTURER SNAPNRACK DRWN A.TANTAKARN GROUND LUG 2.A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CHKD E.IM CONTINUOUS ROW OF MODULES SS BONDING PIN ; ' /,- \ DATE 03/21/2022 3.GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL 4.GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR SCALE- _ �--- MODULE / I CHANNEL NUT PERPENDICULAR TO RAIL / FRAME 5.ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE NTS ( ' RAIL \\ /————— \ TITLE. SS BONDING RAIL ATTACHMENT DETAILS PINS CHANNEL NUT PV-4-1 p+V ROOF ov 1 METER NUMBER:98593646 I � SUNPOWER J PV SUPERVISOR 6 f 1 2 10 11 SUNPONIER ..')\ -41 tel. I _ ___ _ SOIARDECK - --____- STRING OF I i T>,JTIL1T', i1ti SUNPOWER A400 -G-ACy�!' 400VV AC MODULES I PV SYSTEM I 6 WITH SPWR-A4(10 7AS) I I EXTERIOR'WALL LOAD PANEL I INTEGRATED MICRO INVERTER —— IN PARALLEL I 3 G N L,L, I I I lol I UTILITI'METER • ' EGC.ATTACHED \\�/// TO RAIL ROOF I I "* 11 MODUIESISTRING.1.45 PlMOOULE=15.95 AMP LOAD/STP.IVJI I 15 95 AMP x 1.25 CONT DUTY=19 94 AMP 1 WIRE AMPACIT i MIN i I IGA12P I C7 2 I 20A2P I I I I C'7NSUAiPTIOM CTs �i = L -------- ----� 9 NOTE (� O 1 2 9 20A/2p I MSP I THIS MAIN DISTRIUTION Z E; . . . . . . . SUNPnWER 1 I PANEL HAS A 2008 AMP U Z SOLARDECK _____________ -----_--_---- 1 1 MAIN RATED BUS•WITH 2OU 4MF O 1 i MAIN MAIN BREAKER U A E STRING OF I I LOADS Y>s (10)9UNPOWER A400-BLK-G-AC I 1 200 A BUS a 120°0=240 A 0 d c I I 240A-200A MAIN=40A LL N x _ c TH S AC MODULES J 1 THE MAAIMUM BACK FEED V) N'ITH SPWR-A411D 7AS)) I 40Al2P INTEGRATED I I CIRCUIT BREAKER SIZE IS F MICRO INVERTER I 40 AMP PER NEC 207 IN PARALLEL _ _ I SECTION 705.t2IDN2N 3Nb1 �' p EGC ATTACHED L_______ ________ _--_-__-__ Uy_- O I N L L. CONNECTION WITH TO RAIL I - LO AD SIDE PER NEC 2017 �_ 00 10 MO DULESISTRING x 1.45 AJMODULF=14.50 AMP LOAD/STRING EGClGEC SECTION 230_a'151 14.5'AMP x 1 25 CONT DUTY=15.13 AMP OWIRE AMPACITY MINI - G Z c m I Z� GROUND ROD =)y 5 - °LZ mod NDN m u Z Z m 2 SYSTEM DETAILS NEW GRID-INTERACTIVE CONDUIT AND CONDUCTOR SCHEDULE Z F_ PHOTOVOLTAIC SYSTEM J DESCRIPTION I— LU M WITH NO BATTERY CONDUCTOR NUMBER OF CONDUIT RUN Q STORAGE TAG CONDUCTOR TYPE CONDUIT TYPE GAUGE CONDUCTORS SIZE LENGTH Or_ W W DC RATING OF SYSTEM 8,400 WoENPHASE O-CABLE 12 2 N/A NIA 80'-0" 1.— U >_ LL Lu - Z AC RATING OF SYSTEM 7,329 W1 Z a_ LL1 L BARE COPPER GND IN FREE AIR 6 1 N/A N/A 25'-0" — INVERTER(S) SPWR-A4(10 7AS)INTEGRATED IN c/) C/) :3 MODULEENPHASE O-CABLE 12 2 N/A N/A 80'-0" LU z W 0 INVERTER TYPE MICRO INVERTER 2 2i EE c� M BARE COPPER GND IN FREE AIR 6 1 N/A N/A 25'-0" O w } r � MODULE THWN-2 12 4 PVC SCH40 1" 30'-0" U) � SU . NPOWER-A-400-BLK-G-AC U 3 GENERAL NOTES EGC 12 2 PVC SCH. 40 1" 30'-0" v 1. ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION THWN-2 12 3 PVC SCH. 40 1" 10'-0" DRWN A.TANTAKARN INSTRUCTIONS 4 CHKD E.IM 2. ALL PV EQUIPMENT SHALL LISTED BY RECOGNIZED TESTING LAB EGC 12 1 PVC SCH. 40 1" 10'-01, 1 DATE 03/21/2022 3. WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ LINE AND LOAD THWN-2 6 3 PVC SCH. 40 1" 20'-0" SCALE. 4. WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION, THE BREAKER SHALL BE INSTALLED AT THE 5 NTS OPPOSITE END OF THE BASS BAR OF THE MAIN BREAKER GEC 6 1 N/A N/A 20'-0" tl 5. WORK CLEARANCE AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1). 110.26(A)(2), TITLE 110.269(A)(3) 6CLASS 1-16 AWG TWISTED PAIR a 6. ALL EXTERIOR CONDUITS. FITTINGS AND BOXES SHALL BE RAIN TIGH AND BE MIN. NEMA 3R RATED INSTRUMENT CABLE 16 2 PVC SCH. 40 1" 20'-0" 3-LINE DIAGRAM 7. AC AND DC GROUNDING CONDUCTORS PER NEX ARTICLE 690.43(A)THRU(F)CONNECTED AS PER 690.45(A).690.46 AND -- SIZED PER 250.112PP V 5 8. PROVIDE EXPANSION JOINTS AND ANCHORING OF ALL CONDUIT RUNS AS PER NEC REQUIREMENTS V ` 9 PROVIDE LABEL. PLACARD AT EXISTING UTILITY CONNECTION WITH"WARNING-CUSTOMER OWNED ELECTRICAL _ GENERATION EQUIPMENT CONNECTED"WITH APPROPRIATE HAZARD AND OUTPUT RAITING OF PV SYSTEM DC RACEWAYS .�, Q,WARNING _..� PHOTOVOLTAICLABELING NOTES PHOTOVOLTAIC POWER SOURCE DISCONNECT O ALL PLAQUES AND SIGNAGE REQUIRED BY P'• , 1 SEE NOTE NO. 6 NEC ARTICLE AC SOLAR DISCONNECT, NEC 2017 NEC WILL BE INSTALLED AS REQUIRED , g4� O 690.31(13)(3) © ARTICLE 690.14(C)(2) ! Co ��„ 1 �,j�,, LABELS. WARNING(S)AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES f' , TRANSITION BOX �� THAT DANGER, WARNING, AND CAUTION ,&WARNING SIGNS USED THE STANDARD HEADER :;fr ELECTRIC SHOCK HAZARD 2 COLORS, HEADER TEXT, AND SAFETY ALERT O2 SYMBOL ON EACH LABEL. THE ANSI F? �� 1 •� ��?h1 O DO NOT TOUCH TERMINALS EQUIPPED TERMINALS ON BOTH THE LINE AND STANDARD REQUIRES A HEADING THAT IS AT v�� LOAD SIDES MAY BE ENERGIZED RAPID SHUTDOWN LEAST 50% TALLER THAN THE BODY TEXT, IN ' ��- INTHEOPENPOSITION L ACCORDANCE WITH NEC ARTICLE 110.21(B) i AT THE EACH DISCONNECTING SEE NOTE NO. 7 NEC ARTICLE A PERMANENT PLAQUE OR DIRECTORY SHALL INVERTER O MEANS FOR PHOTOVOLTAIC O 690.56(C) BE INSTALLED PROVIDING THE LOCATION OF EQUIPMENT. NEC ARTICLE THE SERVICE DISCONNECTING MEANS AND O O ® 690.17(4) 3 THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME Q = LOCATION IN COMPLIANCE WITH NEC -� 0`r INVERTER OUTPUT CONNECTION 690.56(8) O ? E Z AWARNING DO NOT RELOCATE THIS 1 O OVERCURRENTDEVICE WHERE THE INVERTERS ARE REMOTELY Y o DISCONNECT SWITCH ELECTRIC SHOCK HAZARD �- -- LOCATED FROM EACH OTHER, A DIRECTORY o>x THE DC CONDUCTORS OF IN SHALL BE INSTALLED AT EACH DC Q D THIS PHOTOVOLTAIC SYSTEM Q SOLAR BREAKER (MSP) NEC PHOTOVOLTAIC SYSTEM DISCONNECTING I- O © ARE UNGROUNDED AND v ARTICLE 705.12(D)(2)(3)(B) MEANS, AT EACH AC IS CONNECTING MEANS. N o MAY BE ENERGIZED 4 AND AT THE MAIN SERVICE DISCONNECTING 0 MEANS SHOWING THE LOCATION OF ALL AC G O3 AT EACH DEVICE WHERE GQWARNING AND DC PHOTOVOLTAIC SYSTEM ENERGIZED, UNGROUNDED DISCONNECTING MEANS IN THE BUILDING, IN _ o Z MAIN SERVICE PANEL CIRCUITS MAY BE EXPOSED DUAL POWER SUPPLY ACCORDANCE WITH NEC 690.4(H) DURING SERVICE. NEC ARTICLE f SOURCES:UTILITY@RID AND (n 690.35(F) PV SOLAR ELECTRIC SYSTEM ' THE MATERIALS USED FOR MARKING MUST Z O © O ® O BE WEATHER RESISTANT, IN COMPLIANCE POWER O ANY AC ELECTRICAL PANEL 5 WITH CBC 511.3.1. IT IS RECOMMENDED THAT • PHOTOVOLTAIC SOURCE THAT IS FEED BY BOTH THE UL 969 BE USED AS STANDARD TO 1 RATEDO •• • • UTILITY AND THE DETERMINE WEATHER RATING ZO MAX SYSTEM VOLTAGE t 507 VDC _j PHOTOVOLTAIC SYSTEM (MSP) LABEL(S) WITH MARKING"WARNING: F: Lu RATED MPP CURRENT=72 AMPS NEC ARTICLE 705.12 D)(4) : � SHORT 68 , ( PHOTOVOLTAIC POWER SOURCE" SHALL BE Q � • LOCATED EVERY 10 FEET OF EACH DC � W W DC DISCONNECT, NEC ARTICLE RACEWAY AND WITHIN ONE FOOT OF EVERY O 1.- U 0) >_ ® 690.53 (FOR REFERENCE ONLY) CAUTION . 6 TURN OR BEND AND WITHIN ONE FOOT LL W L z ABOVE AND BELOW ALL PENETRATIONS OF Z POVVER TO THIS • • • ROOF/CEILING ASSEMBLIES.. WALLS AND w °LJ U) (/ SUPPLIED •• • • • BARRIERS. THE LABEL SHALL HAVE 3/8"TALL W Z W 0 o • • • VVITH DISCONNECTS • •AS SHOVVN: LETTERS AND BE REFLECTIVE WITH WHITE 2i IY r- = TEXT ON A RED BACKGROUND 0 SERMCE••METERING LABEL(S) WITH MARKING "PHOTOVOLTAIC WUTILM F- U • •• SYSTEM EQUIPPED WITH RAPID SHUTDOWN." Q • I i � ALTERNATIVE PO'.&R SHALL BE LOCATEDSOURCE AC OISCONNECT U U ••.•� 7 POINT-OF-INTERCONNECTION OR AT MAIN DRWN A.TANTAKARN AC DISCONNECT, NEC ARTICLE IIWERTERWI 1> i L SERVICE DISCONNECT. THE LABEL SHALL CHKD E.1M �':'• HAVE 3/8''TALL LETTERS AND BE REFLECTIVE DATE 03/21/2022 5 690.54 (FOR REFERENCE ONLY) '�••�•�� - O WITH WHITE TEXT ON A RED BACKGROUND scALe. NTS POINT OF INTERCONNECTION OR AT MAIN 1 O TITLE. SERVICE DISCONNECT(MSP), NEC ARTICLE SAFETY LABELS 690.54 (FOR REFERENCE ONLY) Pv_c