HomeMy WebLinkAbout49210-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE 14 '� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49210 Date: 5/4/2023 Permission is hereby granted to: HSA Holdings LLC C/O Sean H. Peters 108 Remington Rd Manhasset, NY 11030 To: install generator as applied for. Maintain a minimum of 15' from side lot lines. At premises located at: 2000 Park Ave, Mattituck SCTM # 473889 Sec/Block/Lot# 123.-8-7 Pursuant to application dated 4/4/2023 and approved by the Building Inspector. To expire on 11/2/2024. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $235.00 Building Inspector i= TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.soutlioldtownny.gov wo, Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only 4 PERMIT NO, Building Ins9e on is h � Q C k j Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is riot the owner,an Owner's Authorization form(Page 2)shall be completed. Date: Z OWNER(S)OF PROPERTY: Name: �� ,t� v�N6s GL C. ECTM # 1000-/2- Project Address: POO �.��t��✓G Phone#: � �(Co Email: Mailing Address: 2 11 qwA— III-e—AWA ji%T�C.t. ^/e CONTACT PERSON: Name: Mailing Address: G1� Phone#: Email: r � ^ {ti� LA-16— DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address:. Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Will the lot be re-graded? ❑Yes ErNo Will excess fill be removed from premises? ❑Yes f o PROPERTY INFORMATION Existing use of property: �eIntended use of property: �� Zone or use district in which premises is situated: Are there any covenants and r strictions with respect to no this property? ❑Yes o IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other,applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as hereindescribed.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 220AS of the New York State Penal Law. Application Submitted By(print name),. �uthotiizeid Agent ❑Owner Signature of Applicant: CONN Date:BNCFi Notary Public,State of New York STATE OF NEW YORK) No. 01BU6185050Qualified in Suffolk County SS: Commission Expires April 14, 2 Q l� COUNTY OF ) / being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the A6—e,-,j 7— (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this dayof,4:11P fy 20a,:�) iso Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) residing at eve do hereby authorize " � to apply on mybehalf to th own uthold Building Department for approval as described herein. r 2 , Z -;� -" , - wher s Signature Date Print Owner's Name 2 BUILDING DEPARTMENT Ele ici ns ) I2q ' TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - POAIR -. ,5J, v Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 N ro err southoldtownn y.golv — seand southoldtownn . ov da""eCd, APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 03/30/2023 Company Name: Modern Electric East, Inc. Electrician's Name: T. Rutkowski License No.: ME-4253-E Elec. email:trut299@aol.com Elec. Phone No: 516-903-7151 E I request an email copy of Certificate of Compliance Elec. Address.: PO Box 321, Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: Sean Peters Address: 2000 Park Avenue, Mattituck, NY 11952 Cross Street: Bungalow Lane Phone No.: 631-445-4348 Bldg.Permit#: qq alo email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Wiring of Standby Generator Square Footage: Circle All That Apply: Is job ready for inspection?: R/ YES NO Rough In El Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service SizeF-11Ph E]3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame 0 Pole Work done on Service? Y nN Additional Information: PAYMENT DUE WITH APPLICATION alA ss-�oars GENERACX/22/K kW ° GUARDIAN° SERIES _ Residential Standby Generators Air-Cooled Gas Engine Standby Power Rating r , INCLUDES: G007038-1.G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-2D kW 60 Hz • True Power'"Electrical Technology G007042-2;G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz G007209-0,G007210-1 (Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution"controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available C� • Electronic governor I b Q • Standard Wi-Fi°connectivity • System status&maintenance interval LED indicators 11 • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation GENERAC I • 5 Year limited warranty ' • Listed and labeled for installation as close as 18 in(457 mm)to a structure.` "Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. cONor CLEDUS QV In tX O Note:CER or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN &RIGOROUS TESTING are at the heart of Gen- "O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK°CONNECTIVITY:FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. GENERAC @(&F PROMISEti GENERACO VMS kW Specifications Generator Model G007038-1 G007042-2 G007038-3 G007042-3 G00720M G007039-1 G007043-2 G007039-3 G007043-3 G007210-1 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Rated maximum continuous power capacity(LP) 20.000 Watts' 22,000 Watts' 20,000 Watts' 22,000 Wafts' 24,000 Watts' Rated maximum continuous power capacity(NG) 18,000 Watts' 19,500 Watts` 18,000 Watts' 19,500 Watts' 21,000 Watts' Rated voltage 240 Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 Total Harmonic Distortion Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Phase 1 Number of rotor poles 2 1 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(lb/kg) 448/203 466/211 436/198 445/202 455/206 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load" 67 67 67 67 67 Sound output in dB(A)at 23 ft(7 m)with generator in Quiet-Test'"low-speed exercise mode" 55 57 55 57 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx.l.9 qt/1.8 L Operating rpm 3,600 Fuel consumption Natural gas tt3/h2 Loa) 1 204(5.78) 228(6.46) 164(4.64) 203(5.75) Ful Load 301(8.52) 327(9.26) 287(8.13) 306(8.66) Liquid propane ft3/hr(gal/hr)[Mrl 87(2.37)[8.99] 92(2.53)[9.57) 86(2.36)[8.95] 92(2.53)[9.571 1/2 Load Full Load 130(3.56)[13.481 142(3.90)[14.77] 136(3.74)[14.151 142(3.90)[14.771 Note:Fuel pipe must he sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,1 D-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Retum to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Faull/Missing AC waming Standard Low Baftery/Baltery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Faultpncorrect Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard —Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).'Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level;and also will decrease approximately 1%for each 10"F(6°C)above 60'F(16°C). GENERAC® 10/22/2 kW Switch Options Service Rated Automatic Transfer Switch Features 6007039-1,G007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. Model 9007043-2,G007043-3(22 kW) _ 6007210-1(24 kW) • Up to eight additional large(240 VAC)loads can be managed when used in conjunction No.of poles 2 with Smart Management Modules(SMMs). Current rating(amps) 200 • Electrically operated,mechanically-held contacts for fast,clean connections. Voltage rating(VAC) 120/240,10 • Main breakers are rated for 80%continuous load. Utility voltage monitor(fixed)- -Pick-op 80% r • 2-pole,250 VAC contactors. -Dropout 65% • Service equipment rated,dual coil design. Retum to utility* Approx.13 sec EfL or UL listed Standard • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. 'W9 range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly W, 200 Amps 120/240,1a Open Transition Service Rated Height Width Depth H1 H2 W1 W2 inE67.95 30.1 10.5 13.5 6.9 cm 76.43 26.67 34.18 17.5 "' Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MGM-#6 350 MGM-#6 210-#14 0 , O GENERAC® [22/94 W Available Accessories _ Model# Product Description GO07101-0 Battery Pad Wanner Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF(-18°C).(Not nec- essary for use with AGM-style batteries). , G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0 IF(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. .GO05621-0 ,Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured (Standard on 22/24 kW) 'appearance as well as offering protection from rodents and insects by covering the lifting hales located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. 13006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-F enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0-413 LTE Mobile LinkO Cellular The Mobile Linkfamily of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-Ft/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs Model UPC 37.6 1.1 �,�o,�, G007038-1 696471074185 r25.1 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727.2—lt G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 o at o 0 G007209-0 696471071511 G007210-1 696471084801 668 mm 1232 mm t35.51nj L48.51.1 LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G E N E RACO Generac Power Systems,Inc. •S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2021 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Pan No.A00DO937814 Rev.D 04/14/2021