Loading...
HomeMy WebLinkAbout45961-Z rasr �o�pS�FF�t CGr Town of Southold 4/4/2023 a P.O.Box 1179 W 53095 Main Rd oy o� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43981 Date: 4/4/2023 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 1075 Clipper Dr, Southold SCTM#: 473889 Sec/Block/Lot: 79.4-17.5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/3/2021 pursuant to which Building Permit No. 45961 dated 3/19/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: additions and alterations, including"as built"finished basement,to existing single family dwelling as applied for. The certificate is issued to Kelleher,Terence&Margaret of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R-21-2396 5/4/2022 ELECTRICAL CERTIFICATE NO. 45961 10/14/2021 PLUMBERS CERTIFICATION DATED A or 'gnature o�SUFFnt,��o TOWN OF SOUTHOLD �� ay BUILDING DEPARTMENT ce 0 TOWN CLERK'S OFFICE_ oy • �g SOUTHOLD, NY 0 - BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45961 Date: 3/19/2021 Permission is hereby granted to: Kelleher, Terence 1075 Clipper Dr Southold, NY 11971 To: legalize "as built" finished basement as applied for. Additional certification will be required. At premises located at: 1075 Clipper Dr, Southold SCTM #473889 Sec/Block/Lot# 79.-4-17.5 Pursuant to application dated 3/3/2021 and approved by the Building Inspector. To expire on 9/18/2022. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $1,240.80 CO-ALTERATION TO DWELLING $50.00 Total: $1,290.80 A - Bui g Inspector pF SO!/r�,ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 aQ sean.deviin@town.southold.ny.us Southold,NY 11971-0959 �yCow T`1,�1c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Terence Kelleher Address: 1075 Clipper Dr city:Southold st: NY zip: 11971 Building Permit#: 45961 section: 79 Block: 4 Lot: 17.5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Generation Green Electric Inc License No: 4483ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor Pool New Renovation X 2nd Floor Hot Tub Addition X Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 27 Ceiling Fixtures 11 Bath Exhaust Fan 1 Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures 1 Smoke Detectors 3 Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures 26 CO Detectors 1 Sub Panel A/C Blower 2 Range Recpt Ceiling Fan 2 Combo Smoke/CO 3 Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 1 g 4'LED Exit Fixtures Pump Other Equipment: Minisplit AC Notes: AS BUILT NO VISUAL DEFECTS " Finished Basement, 2 Bedrooms & Bathroom Inspector Signature: ate: October 14, 2021 S.Devlin-Cert Electrical Compliance Form o�aq SObTyOr # # TOWN OF SOUTHOLD BUILDING DEPT." ca765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ INSULATION/CAULKING L [ ] FRAMING /STRAPPING [ ] FINALE"j'sw K'b 4 v� [ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY-INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: 111f4l IDA �� mwIV DATE 6 o� INSPECTOR 1�kl ho,\\OFSOUlyo6 S� W79 * * TOWN F SOUTHOLD BUILDING 'DEPT. 765-1802 -INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE-SAFETY INSPECTION- FIRE NSPECTIONFIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] :ELECTRICAL (ROUGH) KA ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: 1-� � DATE 2 INSPECTOR i tv SOblyo6 # # TOWN OF SOUTHOLD BUILDING DEPT. �y�ourm '' 765-1802 : INSPECTION [ ]' FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND . [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: 4�0 DATE �� INSPECTOR Yom` ty souTyo� ySRb.� 075 C W Pom -PK # # TOWN OF SOUTHOLD BUILDING DEPT. coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: r o QTS ,4N swl9jQ DATE INSPECTOR v IF SOUIyo� q s;cj # # TOWN OF-SOUTHOLD BUILDING DEPTL caorm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 4M PL 0 r . 1.01 a 5�041 6! 09 Cz ,(4 alvi JASVg�,-_� 011 DATE �'J INSPECTOR pF SOUIY 107--s- 1 G/ / # # TOWN OF LUTHOLD BUILDING f(,� JL/_PT. G Q � - `ycnuMr��'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. ( ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: Ans rtil�� A'tl��-1 On 7; agnz 'N1.f DATE INSPECTOR Robert I. Brown Architect, P.C. 205 Bay Avenue,Greenport,NY 11944 info@ribrownarchitect.com 631-477-9752 it fJ LTJ 22 December, 2021 Mr. Michael Verity, Chief Building Inspector G DEC g 7n71 h i! Town of Southold Building Department DU:L DEPT Southold,NY 11971 Towe'.C=SQU10LD Re: Kelleher Residence 1075 Clipper Drive Southold,NY Building Permit No. #45961 Dear Mr. Verity, This letter is to confirm that based on the site inspection conducted on Tuesday December 21St, 2021 of this project by my staff under my supervision, and to the best of my knowledge, belief and professional judgement,the concrete footing and foundation wall as installed complies with the plans and applicable building codes. If you have any questions, or require additional information, please feel free to contact me. Thank you for your attention to this matter ED AF? 0 Sincerely,__�� _ Robert Brown, A.I.A. sX 1634A FOF NE`N Robert I. Brown Architect, P.C. 205 Bay Avenue,Greenport,NY 11944 � (,-7,) info@ribrownarchitect.com I DY 631-477-9752 JAN 2 2022 _ 20 January, 2022 BUILU�ivt''a�: TOWN OF SOM'HOLO Mr. Michael Verity, Chief Building Inspector Town of Southold Building Department Southold,NY 11971 Re: Kelleher Residence 1075 Clipper Drive Southold, NY 11971 Building Permit No. 445961 Dear Mr. Verity, This letter is to confirm that based on the site inspection conducted on Friday January 14th, 2022 of this project by my staff under my supervision, and to the best of my knowledge, belief and professional judgement, the structural framing and strapping as installed complies with the plans and applicable building codes. If you have any questions, or require additional information, please feel free to contact me. Thank you for your attention to this matter D A�C'�i pT 1.eq T6` Sincerely, U!4 Robert Brown, A.I.A. s '� Robert I. Brown Architect, P.C. 205 Bay Avenue,Greenport, NY 11944 info@ribrownarchitect.com 631-477-9752 06 April, 2022 Mr. Michael Verity, Chief Building Inspector APR Town of Southold Building Department 7 2022 Southold,NY 11971 BUILDING DEPT. TOWN OFSOUTHOLD Re: Kelleher Residence 1075 Clipper Drive Southold,NY 11971 Building Permit No. 45961 Dear Mr. Verity, This letter is to confirm that based on the site inspection conducted on Tuesday April 5`n, 2022 of this project by my staff under my supervision, and to the best of my knowledge, belief and professional judgement, the insulation in the walls and ceiling as installed complies with the plans and applicable building codes. The results of the inspection are as follows. The insulation installed in the ceiling was closed cell spray-in foam insulation. The insulation installed in the first and second floor exterior walls was 2.5" closed cell spray-in foam insulation(R-16) and R-13 batt insulation. R-21 batt insulation was installed in the existing walls where the new addition touches the existing structure. And R-22 batt insulation was installed in the floor joists If you have any questions, or require additional information, please feel free to contact me. Thank you for your attention to this matter o � SOF t Sincerely, Robert Brown, A.I.A. ���1 -•. �� i Y h f Y{ :t. f .`.sem.. +.e. .. 'i r Y. r �� ., � i �r� ' r;,. '� � � = �� - �� ��� � � . � � � , . :� :� . �� �, � � ut rw w E:ax k r r R �Ior 7. FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) y ------------------------------------ 'FOUNDATION (2ND) y H z cn 1� d ROUGH FRAMING& PLUMBING ` •�`3 1 INSULATION PER N.Y: STATE ENERGY CODE VIA. G • oh -PW 13pthn � J � FINAL ADDITIONAL COMMENTS 1-cl -a 1 IDA co+Rp 9 34504 l IN ia- all e .ob "'.' tcc--=i'Fl 000 eco - ►- nk c 1 s .;9,05,00 "IT1 t ic. �m 12 a2- --S 4k adds a ,to Z Z u c�� 2cG 6 K aIRAAe-� Z 1301- � z e 4 �gUff�t��o =o �� TOWN OF SOUTHOLD—BUILDING DEPARTMENT N x{ Town Hall Annex 54375 Main Road P. Q.Box 1179 Southold,NY 11971-0959 oy�0 0� Telephone(631)765-1802 Fax(631)765-9502 htti)s://www.southoldtownny.gov 1 3 Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only _. :✓ `'; '4 PERMIT NO. Building Inspector: MAR - 3 2021 Applications and forms must lie.filled out in their entirety:Incomplete. applications will-not be accepted.. Where the Applicantls not the owner,ar O.wner's Authorization form,.(Page,Z):shall:be completed:'. Date: 03/02/2021 OWNER(S)OF PROPERTY: Name Terence and Margaret Kelleher ScrM#1000-79.-4-17.5 Project Address:' 1075'Clipper Drive, Southold, NY- 11971 Phone#:646-808-4601 Email: tkelleheresq@gM?iil..com Address: 1075 Clipper Drive, Southold,,NY 11971 CONTACT PERSON: _ Name:Karen Szczotka, Agent _. Mailing Address:205 Bay Ave., Greenport, NY 11944 Phone#:631-477-9752 Email: karen ribrownarchitect.com DESIGN PROFESSIONAL INFORMATION Name: Robert I. Brown AIA Mailing Address: 205 Bay Ave., Greenport, NY,,1,1944 Phone#: 631-477-9752 Email: rob@ribrownarchite.ct.com , CONTRACTOR INFORMATION: Name: Quarty Construction LLC Mailing Address: p0 Box 1949, Southold,, NY 11971 Phone#: 516-381-3137 (cell) Email: quartystruction@g 1pil.com con DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair El Demolition Estimated Cost of Project: ROther As-Built Basement $ Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes BNo 1 PROPERTY INFORMATION Existing use of property:S � ,fin n ,,, Intended use of property: 5 _ Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Ely es ❑No IF YES, PROVIDE A COPY. Check Box After_Reading: The owner/contractor/design professional is responsible for all drainage and'storm water issues as provided by 'Chapter 236 of the Town"Code. APPLICATION IS HEREBY MADE to.the Building Department for the.issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described:The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name OAuthorizedAgent ❑Owner Signature of Applica Date: STATE OF NEW YORK) CONNIE D.BUNCH SS: Notary Public,State of New York No.01BU6185050 COUNTY OFc.� (_,� ) Qualified In Suffolk County Commission Expires April 14,2 OQ L' ya being duly sworn, deposes and says that(s)he is the applicant ((' am of individual signing contract)above named, (S)he is the (Contracto , gent, rporate Offic r,etc.) of said owner or owners,and is duly authorized to or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this �v v Ilay of �Cl/1 _ 20 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at /� do hereby authorize e')/4'�) l; t to apply on my behalf to the Town of Southold Building Department fpr a proval as describe herein�( ZZ -�-'.Ogwner, Signature Date Print Owner's Name 2 r ' S,4FF C E � U E UILDING DEPARTMENT-Electrical Inspector CO -b..CT 1 22021 Hall TOWN OF SOUTHOLD x Annex- 54375 Main Road - PO Box 1179 ip • .W N'OF SOULDING TTHOLD Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ro err southoldtownnv aov- seand(a southoldtownny aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (A�InfoationRequired) Date: Company Name: Uj �- * [ / 12(012- ofElectrician's Name: C ��oh n eLicense No.: �-{ Elec. email: E le Phone No: G�� _Zt4O-7 El I request an email copy of Certificate Elec. Address.: Qb 1�� �� 1 l�cz JOB SITE INFORMATION (All Information Required) Name. 2�C� Q, �0- Cross - E'_`*e�— Address: �l on PF � � �Street: Phone No.: 63 S BIdg.Permit#:� email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK INCLUDE SQUARE FOO AGE (Pease Print Clearl ): Circle All That A PPy:I Square Footage: Is job ready for inspection?: YES[]NO []Rough In F] Final Do you need a Temp Certificate?: YES[-\�KO Issued On ----------------- Temp Information: (All information required) Service SizeM1 Ph❑3 Ph Size: _A #Meters Old Meter# ❑New Serviceo Fire Reconnect[]Flood Reconnect Oservice Reconnect[]Underground[]Overhead # Underground Laterals 1 n2 H Frame n Pole Work done on Service? My F1N Additional Information: PAYMENT DUE WITH APPLICATION �" &C1 � �� Z' , g�FF C E P W E UILDING DEPARTMENT-Electrical Inspector TOWN OF 9OUTHOLD CR .CT. 1 22021 Hall Annex- 54375 Main Road - PQ Box x 1179 o ` UILDING DEPT... Southold, New York 11971-0959 .fi WN OF SOUTHOLD 44 Telephone (631) 765-1802 - FAX (631) 765-9502 roclerra-southoldtownny aov - seand(aisoutholdtownny. ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: / 1 2O Company Name: �� GrI0,0(\ �Q ,C Electrician's Name: Oln N License No.: {L [� Elec. email: Elec. Phone No: �� -Z'-lQ7 ISI request an ail copy of Certifica of Compliance Elec. Address.: �JY 11 102 ,JOB SITE INFORMATION (Ail Information Required) Name: CE'_--a 0Y Address: Cross Street: Phone No.: i Bldg.Permit#: email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK INC UDE SQUARE FOOAGE ease se Print Cleary .. � l.�s � ti: �O&S) � (, -box, Circle All That Apply: Square Footage: 6 Is job ready for inspection?: YES❑NO ❑Rough In Final Do you need a Temp Certificate?: YES O ❑ Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service0 Fire ReconnectE]Flood Reconnect[]Service Reconnect[]Underground[]Overhead #Underground Uaterais 1 F12 F1 H Frame Pole Work done on Service? nY nN Additional Information: PAYMENT DUE WITH APPLICATION 0 &U � �'� PERMIT# ` Address: Switches , 1 Outlets I �� G F I's Surface. Sconces HH s UC Lts FansFrid'.e...._....:...... .: ..,.,,- .:...:..:. ..:._ .. _, .-.. . Exhaust Oven W/p Smokes DW Mini. Carbon._:..:.,., _... ..r ...._.. ...._..._.. _......,..; ..;'M°ico....._._.. : ..._.... .... _.. ....Generator T. Coml?<o.,.�... 1._:,.. :.:._. Cooletop _. Transfer : AC . AH Hood Service , Ve •'Amps Ha -'Used Special;. .: _._..... ....::: .... :..._....... _ ...... Comments: F014, BUILDING DEPARTMENT- Electrical Inspector ��O Gym TOWN OF SOUTHOLD CZ z Town Hall Annex- 54375 Main Road - PO Box 1179 c • Southold, New York 11971-0959 y Off' Telephone (631) 765-1802 - FAX (631) 765-9502 �Ol rogerr(cbsoutholdtownny.aov — seand(a)-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: M a rcl -,�2l Company Name: au b A a lec - L Name: ,r- License No.: �-70 2- M E email: CJ 6 -�o�►Cr ne o n r Phone No: - q 7 S r I request an email copy of Certifica a of Compliance Address.: JOB SITE INFORMATION (All Information Required) Name: eren cC Lj e- el- Address:' / lAddress: Q'7,5'- C r i v'P- So,+Iiu,ld IVY Cross Street: lc� k L�n2 Phone No.: - FAo-S,),r Z 6 A& ?L0F �. BIdg.Permit#: L S J(. 1 email: -1-1<e 1 .e er-CS @ ,2` ,c04 Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) ,q (�� k;OVA `Red ew,tY6 Q_y►c2 l)us'eeren-7 as b,j+ A l so Check All That Apply: Is job ready for inspection?: DYES ❑NO ❑Rough In ❑Final Do you need a Temp Certificate?: ❑YES NNO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION J� A Electrical Inspection Form 2020.xlsx JV 16O l� h c c ®��f p } BUILDING DEPARTMENT- Electrical Inspector ® ', TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box,1179 cz %' �� Southold, New York 11971-0959 ®�� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a)southoldtownny.gov — seand(a)southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: rn c, Company Name: Name: �- License No.: LJ -70q-- ME email: LJ -Fv�►(.i nc�s h i Phone No: _ y79- 1 r I request an email copy of Certificate of Compliance Address.: JOB SITE INFORMATION (All Information Required) Name: ere,6 cf- L I e-fi e f- Address: 107S - C , er- n� So-+61d fd v Cross Street: A -r L L n 2 Phone No.: eAp- S.2S_ ` ?OF q Bldg.Permit#: L1 61( email: .fi j��j .e �l`�So Q' cup Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) CICS bLAil+ APB?) B?) Check All That Apply: Is job ready for inspection?: DYES ❑NO ❑Rough In ❑Final Do you need a Temp Certificate?: DYES NNO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground []Overhead # Underground Laterals ❑1 02 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION N � Electrical Inspection Form 2020.xlsx (�O �`"�/ N PERMIT # Address: Switches I Outlets f-u f \1 �GFI's Surface Sconces l� H H's JJ r 1 l UC Lts Fans VV(_ n / Fridge HW �bv Exhaust ( Oven WAD Smokes II DW Mini Carbon I Micro Generator Combo Cooktop Transfer ` A�` Hood Service X[A 1 Amps Have Used Special: Comments ROBERT I. BROWN, ARCHITECT P.C. 205 BAY AVENUE GREEN PORT, NY 11944 631-477-9752 FAX 631-477-0973 info oribrownarchitect.com Transmittal Date: March 2, 2021 To: Town of Southold Building Department Re: Kelleher Residence Application for As-Built Basement (CO) Enclosed please find application and contractor certificate of insurances for the above application of"As-Built" basement. Thank you, Karen Szczotka Agent for Robert I. Brown Architect, PC 1075 Clipper Drive Southold,New York 11971 631.876.5257- cell 646.808.4601 tkelleheresq@gmail.com L� l MAR 8 2�L J ROBERT I. BROWN, ARCHITECT P.C. 205 BAY AVENUE GREENPORT, NY 11944 631-477-9752 FAX 631-477-0973 info@ribrownarchitect.com Transmittal Date: 9/23/21 To: Town of Southold Building Dept Re: Kelleher Residence 1075 Clipper Drive Southold,NY BD Permit#: 45961 Enclosed please find modification to the above referenced permit. Thank you, Karen Szczotka Agent for Robert I. Brown Architect, PC karen@ribrownarchitect.com y 5 9(O I ROBERT I. BROWN, ARCHITECT P.C. 205 BAY AVENUE GREENPORTI NY 11944 631-477-9752 FAX 631-477-0973 info@ribrownarchitect.com Transmittal Date: 5/10/2022 To: Town of Southold Building Department Re: Kelleher Residence 1075 Clipper Drive SCDHS Final approval Enclosed please find an original copy of SCDHS final approval survey. Thank you, Karen Szczotka Agent for Robert I. Brown Architect, PC ROBERT I. BROWN, ARCHITECT P.C. 205 BAY AVENUE GREENPORT' NY 11944 631-477-9752 FAX 631-477-0973 infoo-ribrownarchitect.com Transmittal Date: 06 April, 2022 To: Southold Town Building Dept. APR 7 2022 sUiwiNG ntpT Re: Kelleher Residence T®WN OFSOUTH6LD 1075 Clipper Drive Southold,NY 11971 Building Permit No. 45961 Attached please find a letter of inspection for the insulation Thank you, Robert I. Brown Architect, PC AC0C>R1:> 02/25/22021021® CERTIFICATE OF LIABILITY INSURANCE DATE(MM/ ) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,.AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: MATTHEW DALEY Matthew Daley FHONNo.Ext: 631-744-3350 a No;631-744-3383 I C.Farm FamilyInsurance E-MAIL ADDRESS: may� y•tt.dale farm-famil com 85 Echo Avenue-Suite 2 INSURERS AFFORDING COVERAGE NAIC# Miller Place, NY 11764 INSURER A: Farm Family Casualty 13803 INSURED INSURER B: United Farm Family 22963 Quarty Construction LLC INSURERC: ShelterPoint Insurance P.O. Box 1949 INSURER D INSURER E: Southold NY 11971 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDLITYPE OF INSURANCE INSD SUER POLICY NUMBER MM EXP LTR IDDIYYYY MM/DD LICY EFF POLICY YYYY LIMITS A X COMMERCIAL GENERAL LIABILITY 3152X1261 11/08/20 11/08/21 EACHOCCURRENCE $ 1,000,000 RENTED CLAIMS-MADE 7XI OCCUR PREM SESOE.occurrence) $ 100,000 MED EXP(Any one person) $' 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X JECT ❑ LOC PRODUCTS-COMP/OPAGG $ 2,000,000 POLICY❑ 0 PRO OTHER: $ A AUTOMOBILE LIABILITY 3152137187 07/26/20 07/26/21 COMBINED SINGLE LIMIT $ 1,000,000 Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ X AUTOS ONLY Ix AUTOS ONLY Per accident A X UMBRELLA LIAB X OCCUR 3101 E2230 03/17/20 03/17/21 EACH OCCURRENCE $ 5,000,000 EXCESS LIAB CLAIMS-MADE 03/17/21 03/17/22 AGGREGATE $ 5,000,000 DED I I RETENTION$ $ B WORKERS COMPENSATION 3101 W9112 08/24/20 08/24/21 STATUTE ER AND EMPLOYERS'LIABILITY ANYPROPRIETOR/PARTNER/EXECUTIVE YIN N/A E.L.EACH ACCIDENT $ 100,000 OFFICERIMEMBEREXCLUDED7 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 100,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 5()0,000 C NYSDBL DBL295444 08/23/20 Indefinite STAUTORY DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CONSTRUCTION CERTIFICATE HOLDER CANCELLATION Town of Southold 54375 Route 25 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE PO Box 1179 THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold, NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Generated by REScheck-Web Software Compliance Certificate Project Kelleher Addition Energy Code: 2018 IECC Location: Southold, New York Construction Type: Single-family Project Type: Addition Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 1075 Clipper Drive Terence and Margaret Kelleher Robert I Brown Architect P.C., Southold, NY 11971 205 Bay Avenue Greenport, NY 11944 631-477-9752 info@ribrownarchitect.com Compliance: 11.5%Better Than Code Maximum UA: 104 Your UA: 92 Maximum SHGC: 0.40 Your SHGC: 0.29 The%Better,or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. i Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Perimeter Ceiling: Flat Ceiling or Scissor Truss 260 49.0 0.0 0.026 0.026 7 7 Wall -Downstairs: Wood Frame, 16" o.c. 504 28.0 0.0 0.050 0.060 22 27 Door: Glass Door(over 50%glazing) 40 0.300 0.320 12 13 SHGC: 0.26 Window: Wood Frame 4 0.290 0.320 1 1 SHGC: 0.31 Window 2: Wood Frame 4 0.290 0.320 1 1 SHGC: 0.31 Window 3: Wood Frame 10 0.300 0.320 3 3 SHGC: 0.31 Wall-Upstairs: Wood Frame, 16" D.C. 504 28.0 0.0 0.050 0.060 23 28 Window 1: Wood Frame 4 0.290 0.320 1 1 SHGC: 0.31 Window 2: Wood Frame 4 0.290 0.320 1 1 SHGC: 0.31 Window 3: Wood Frame 15 0.300 0.320 5 5 SHGC: 0.31 Window 4: Wood Frame 15 0.300 0.320 5 5 SHGC: 0.31 Floor: All-Wood Joist/Truss 260 22.0 0.0 0.042 0.047 11 12 Project Title: Kelleher Addition Report date: 09/23/21 Data filename: Page 1 of 10 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the manda�ry requirements listed in the REScheck Inspection Checklist. i7 N me-Title Jut-e Date Project Title: Kelleher Addition Report date: 09/23/21 Data filename: Page 2 of 10 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 97.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section plans Verified. Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & 116q.ID 103.1, !Construction drawings and ❑Complies ;Requirement will be met. 103.2 !documentation demonstrate Does Not [PR1]1 !energy code compliance for the ;._. , U :building envelope.Thermal ❑Not Observable !envelope represented on ❑Not Applicable ;construction documents. 103.1, ;Construction drawings and ,•❑Complies Requirement will be met. 103.2, :documentation demonstrate .#❑Does Not 403.7 energy code compliance for [PR3)1 ;lighting and mechanical systems. } t 3❑Not Observable :Systems serving multiple )❑Not Applicable ;dwelling units must demonstrate j ;compliance with the IECC : Commercial Provisions. { i 302.1, Heating and cooling equipment is: Heating: Heating: ;❑Complies :Requirement will be met. 403.7 = sized per ACCA Manual S based Btu/hr Btu/hr ;❑Does Not [PR2]z. on loads calculated per ACCA Cooling: Cooling: ;❑Not Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. ;❑Not Applicable . I Additional Comments/Assumptions: 11 High Impact (Tier 1) 1.2 1 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3) Project Title: Kelleher Addition Report date: 09/23/21 Data filename: Page 3 of 10 SECtlon # Fouitdatian Inspectiori�-� 'Complies? Comments/As'sumptions" :& Req.ID. 303.2,7,• ;A protective covering is installed to ;❑Complies ;Exception: Requirement is not applicable. ['FO l7]2 "protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below ❑Not Observable grade. ❑Not Applicable 403;9: _•, 4Snow-and ice-melting system controls.❑Complies ;Exception: Requirement is not applicable. [FOA-2J2 iinstalled. :❑Does Not ;❑Not Observable i ;❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3" Low Impact(Tier 3) Project Title: Kelleher Addition Report date: 09/23/21 Data filename: Page 4 of 10 Section Plans{Verified' :.Field Verified Framing%`Rough-ln Inspection Complies? ; Comments/Assumptions &`Req D ` :. 402.1.1, 1 Glazing U-factor(area-weighted U- ; U- ;❑Complies ;See the Envelope Assemblies 402.3.1, .average). :[]Does Not table for values. 402.3.3, 402.5 ;❑Not Observable ; [FR2]1 ; 1 ;❑Not Applicable ; 303.1.3 :U-factors of fenestration products ` .j❑Complies :Requirement will be met. [FR4]1 are determined in accordance "*f-� j❑Does Not with the NFRC test procedure or j # U ;taken from the default table. S❑Not Observable ; } i❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ;. .a:.: .; ,°:',_ ,:;.�;,: <=tet ;,:::, ;>.;.,❑Complies ;Requirement will be met. [FR23]1 ;installed per manufacturer's Not instructions. v =s ❑Not Observable ❑Not Applicable 402.4.3 i Fenestration that is not site built "y" , ''' ;t ' ''s"" ;" r"' ''; 1]Complies !Requirement will be met. [FR20]1 :is listed and labeled as meeting : ,,,.a.`h`"-` _. " ❑Does Not AAMA/WDMA/CSA V 101/1.5.2/A440 ` '" F��❑Not Observable for has infiltration rates per NFRC �x -3❑Not Applicable 400 that do not exceed code `}i 'limits. 402:4:5' IC-rated recessed li htin fixtures :y h'S` „:_ 'r '' g g ;.,,_ ._ ,.,.. ,s;;�.. -..❑Complies ;Requirement will be met. [FR16 2sealed at housing/interior/interior finish ❑ l 9 Does Not 2.0 cfm land labeled to indicate ❑Not Observable leakage at 75 Pa. € i ❑Not Applicable 403.3.1 ;Supply and return ducts in attics , ' M,...n;awF)•.:,,: s`=. .`';,: `;_> ❑Complies ;Requirement will be met. [FR12]1 :insulated >= R-8 where duct is >': ❑Does Not U >= 3 inches in diameter and >= ❑Not Observable IR-6 where < 3 inches. Supply and ° 4 return ducts in other portions of i ;❑Not Applicable ;the building insulated >= R-6 for diameter>= 3 inches and R-4.2 'for< 3 inches in diameter. 403.3.2 ;Ducts, air handlers and filter ❑Complies ;Requirement will be met. [FR13]1 boxes are sealed with []Does Not ;;joints/seams compliant with .;❑ Not Observable International Mechanical Code or x "'" 4; i4' 't:... :?2., 4�.:• - ? :International Residential Code, as 's= ._° 3.:. ":" - - :ary ❑Not A licable s:_, : :kt. App ;applicable. f 403.3.5 ,Building cavities are not used as '9 *.,_•,,. ❑Complies ;Requirement will be met. [FR15]3 ducts or plenums. 'a:R', #❑Does Not l ;❑Not Observable �❑Not Applicable 403:4 iHVAC piping conveying fluids R- R- ;❑Complies ;Requirement will be met. [FR17_]2 above 105 °F or chilled fluids ;❑Does Not 1 below 55 °F are insulated to >R- 9j. �3 ;❑Not Observable ❑Not Applicable 403.4.1 ;Protection of insulation on HVAC : ❑Complies ;Requirement will be met. [FR24]1 .piping. 1❑Does Not U i ;❑Not Observable _ _S❑Not Applicable 403.5.3 J'Hot water pipes are insulated to ; R- ; R- ;❑Complies ;Requirement will be met. [FR18]2 !>_R 3. ;❑Does Not (9 ff1 j ;❑Not Observable ❑Not Applicable p ` ❑Complies ;Requirement will be met. 403.6 (Automatic or gravitydampers are A-: =;"�'� ° [FR19]2 installed on all outdoor air + ❑Does Not intakes and exhausts. :- ❑Not Observable ❑Not Applicable 1 lHigh Impact (Tier 1) 1.2.1 Medium Impact(Tier 2) 3 Low Impact (Tier 3) Project Title: Kelleher Addition Report date: 09/23/21 Data filename: Page 5,of10 Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Kelleher Addition Report date: 09/23/21 Data filename: Page 6 of10 Section " Plans.Verified:.- ;'Field.Ver'ified # Insulation lrispection'. Complies? Comments/Assumptions &,Req.ID Value Value 303.1 {All installed insulation is labeled ❑Complies :Requirement will be met. [IN13]2 or the installed R-values ❑Does Not ,I provided. I❑Not Observable ,11hot Applicable 402.1.1, (Floor insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.6 : ;❑ Wood ;❑ Wood :[-]Does Not ;table for-values. [IN1]1 ;❑ Steel ❑ Steel ;❑Not Observable v : ;❑Not Applicable I 303.2, ;Floor insulation installed per ❑Complies ;Requirement will be met. 402.2.8 !manufacturer's instructions and ']❑Does Not [IN2]1 !in substantial contact with the U ;underside of the subfloor, or floor ¢❑Not Observable ' t framing cavity insulation is in ❑Not I Applicable ;contact with the top side of ;sheathing,or continuous insulation is installed on the S underside of floor framing andI ; ;extends from the bottom to the stop of all perimeter floor framing members. ; 402.1.1, !Wall insulation R-value. If this is a; R- R- ;❑Complies ;See the Envelope Assemblies 402.2.5, !mass wall with at least 1A of the E] Wood ;❑ Wood ;❑Does Not ;table for values. 402.2.6 ;wall insulation on the wall ❑ Mass ❑ Mass UNot Observable ' [IN311 lexterior, the exterior insulation ; v l requirement applies (FR10). ;❑ Steel ❑ Steel ;❑Not Applicable i I I i I I i 303.2 ;Wall insulation is installed per "' '';❑Complies ;Requirement will be met. [IN4]1 :manufacturer's instructions. ❑Does Not _ #❑Not Observable 1 I ` ;❑Not Applicable j Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Kelleher Addition Report date: 09/23/21 Data filename; Page 7 of10 Section Plans-Verified_ Field""Verif!ed # Final Inspection Provisions Complies?. Comments/Assumptions & Req.ID Value Value: 402.1.1, (Ceiling insulation R-value. R- ; R- ;❑Complies ;See the Envelope Assemblies 402.2.1, ❑ Wood ;❑ Wood ;❑Does Not table for values. 402.2.2, ; ;❑ Steel ;❑ Steel ;❑Not Observable 402.2.6 [FI1]1 ;❑Not Applicable i ; 303.1.1.1, Ceiling insulation installed per �:;'.- j❑Complies ;Requirement will be met. 303.2 manufacturer's instructions. .` ❑Does Not (F12]1 !Blown insulation marked every 300 ft2. . ,.. ;. ❑Not Observable J❑Not Applicable 402.2.3 " . ;Vented attics with air permeable .;❑Complies ;Exception: Requirement is [F122]2. f insulation include baffle adjacent ❑Does Not !not applicable. !to soffit and eave vents that �. ]extends over insulation. } .• i❑Not Observable I•. ❑Not Applicable 402.2.4 ;Attic access hatch and door ; R- R- ;❑Complies ;Requirement will be met. [FI3]1 insulation >R-value of the ;❑Does Not ;adjacent assembly. ❑Not Observable .:[]Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ;❑Complies :Requirement will be met. [FI17]1 !ach in Climate Zones 1-2, and ;❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable j❑Not Applicable 403.3.3 ;Ducts are pressure tested to cfm/100 cfm/100 ;❑Complies ;Requirement will be met. [FI27]1 determine air leakage with ft2 ft2 ;❑Does Not ;either: Rough-in test:Total ;❑Not Observable ; ,leakage measured with a pressure differential of 0.1 inch ; :❑Not Applicable ;w.g. across the system including ;the manufacturer's air handler ; enclosure if installed at time of ;test. Postconstruction test:Total ;leakage measured with a pressure differential of 0.1 inch w.g. across the entire system ;including the manufacturer's air handler enclosure. 403.3.4 :Duct tightness test result of<=4 cfm/100 cfm/100 ;❑Complies ;Requirement will be met. [F]4]1 :cfm/100 ft2 across the system or ft2 ft2 :❑Does Not F<=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ; i❑Not Observable tests, verification may need to ;❑Not Applicable ;occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated �❑Complies :Requirement will be met. [FI24]1 !by manufacturer at <=2% of }❑Does Not ;design air flow. , ❑Not Observable I❑Not Applicable 403.1.1, Programmable thermostats ;❑Complies :Requirement will be met. [F1912 installed for control of primary >,- ,';,:Y ,❑Does Not heating and cooling systems and initially set by manufacturer to ',y".;".'.' ,'_.;�:,;...;;•• .� y❑Not Observable code specifications. ,_',v:{; `., J❑Not Applicable 1 403.1.2 -,.),Heat pump thermostat installed -'`` ' k" " `? j❑Complies ;Requirement will be met. [FI10]2 Ion heat pumps. E❑Does Not ❑Not Observable i I❑Not Applicable 403•.5.1 (Circulating service hot water }❑Complies ;Requirement will be met. [FI11]2 . (systems have automatic or ❑Does Not iVM accessible manual controls. I Not Observable ❑Not Applicable 11 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Kelleher Addition Report date: 09/23/21 Data filename: Page 8 of 10 Section Plans Verified .','." Fietd'Ve'rifiieil.;.' # Final1nspection Provisions Complies?. Comments/Assumptions & Req:ID Value:,; Value.. 40.6J_:'_ All mechanical ventilations stem : .' "''^ b' `' ❑Complies ;Requirement will be met. ; 4` £ 3 [FI25]?:, ° fans not part of tested and listed �.w; -_� ,���: ,:a� �' ; ❑Does Not HVAC equipment meet efficacy d and air flow limits per Table ' :_ a._: ❑Not Observable❑ �Y.. <4 ` Not Applicable '111403.6.1. 403:2 Hot water boilers supplying heat rni , :J': y ` ❑Com lies :Requirement will be met. n k:° P two i e [FI26j' throw9 -P P 9 h one-or heatin u` ::, :,. n;` :y `, p":<'j' ,f-F ❑Does Not systems have outdoor setback lY`._` ❑Not Observable..0 -.. ;control to lower boiler water <. .,-;q itemperature based on outdoor v ' ''° ❑Not Applicable k . temperature. i 403.5:1.1 ,Heated water circulation systems e.,' :::' `,-'_:.; : rr '• ❑Complies ;Requirement will be met. [FI28]2 ' :. have a circulation pump.The ❑Does Not jsystem return pipe is a dedicated ret urn pipe or a cold water supply; ,r;.;' j❑Not Observable }pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for ,6 icirculating hot water system um s start the um with signal 'f s. ` for hot water demand within thef, - occupancy. Controls ` automatically turn off the pump ? ; :_ ' •' I #when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403;5,.1.2,'. Electric heat trace systems ...... '; ❑Complies ;Requirement will be met. [FI29]? ;comply with IEEE 515.1 or UL f> e ,`"' �" :` fi: �= :.�s......",'��' �` ``�+-� .". ❑Does Not 515. Controls automatically $"'` ❑Not Observable , ]- adjust the energy input to the 3,;.:_:, •:=�` ,:•.=:,-�� �`�' . -�;• •: heat tracing to maintain the `' _;',`: ❑Not Applicable desired water temperature in the I: ;piping T 403:5.2 ,.tDemand recirculation water p ❑Complies ;Requirement will be met. [FI30]z 4systems have controls that p:: = ',>r *`. ❑Does Not manage operation of the pump Wand limit the temperature of the b'` ' ;";'a j•`'::,hurt ON ot Observable water entering the cold water a, "_ = ("'.: ❑Not Applicable ,piping to <= 1044F. 403.5.4 �1 Drain water heat recovery units ,;,; ❑Complies ;Requirement will be met. [FI3l]? itested in accordance with CSA , r4_ Kms° i n m ' ❑Does Not j 1355.1. Potable water-side I pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one •' or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for lindividual units connected to jthree or more showers. ;, 404.1 ;90%or more of permanent ❑Complies ;Requirement will be met. [F16]1 ;fixtures have high efficacy lamps. A.. Z c. ...... `,; ❑Does Not 4 •.,, _ `:. s,. .,:'u5t :. :, ❑Not Observable ❑Not Applicable 404.1.1 Fuel gas lighting systems have m., 9'= ''`' `` " ❑Com lies :Exception: Requirement is F12313ino continuous pilot light. ' ` p p q -]Does Not not applicable. JONot Observable i ap.•a, ❑Not Applicable 4013Compliance certificate posted. f ;;,- `3Y'i ❑Complies z.' [FI7l J' : ...,}i.... ,;°`'.`; '`. ❑Does Not ❑ V. Not Observable { d++�.. -•tr RFs. i ;r•fi :j=. ❑Not Applicable 1 High Impact(Tier 1) 2- Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Kelleher Addition Report date: 09/23/21 Data filename: Page 9 of 10 Section plans,Verified ' . .Field Verified " Final:lnspection Provisions" Complies? Comments/Assumptions & Req.Bp Value " .Value" 303.3 ;Manufacturer manuals for �OComplies 'Requirement will be met. [FI18.P !mechanical and water heating ❑Does Not isystems have been provided. (.s ,., „';:-:.=;:' : '' . '_ r,IE]Not Observable I ' " ❑Not ( t;. 3 Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2 . Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Kelleher Addition Report date: 09/23/21 Data filename: Page 10 of10 i 2018 iEC Energy Efficiency Certificate Above-Grade Wall 28.00 Below-Grade Wall 0.00 Floor 22.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): . . . ing Window 0.30 0.31 Door 0.30 0.26 . . Heating System: Cooling System: Water Heater: Name: Date: Comments LEGEND SUFFOLK COU4TY DEPARTrVIENT O.H ALTM SERVICES CURB APPROVAL Of,CONSTRUCTED WORKS FOR A SINGLE F�!!t 1Y RESIDENCE DROP CURB Date�1 AY fl fl ZM hf.S.Ref.No.-A -a WALL The sewage diapost and water Stl EDGE OF PA VEMEN T Irtsq�ec�d and/or caerli�� �'ft'es at tt11s lorxston have been G`L�ppER DRIVE In � byftOspartmentor �,S� � FENCE OTHER FOR A MAXi�o+J : r00!ISS. + 25 5 o z5.3t HEDGE + �Pz. 0. + 24.92 24.98 + r -. MASONRY r a6 i.. �I r ,... GUIDE RAIL TC 25.60 BC 25.62 25. ..; uf I'�,I'1!'.;rJOc"r ?r-- hl�l e1 TC 25.46 BC 25.20 p 25.22 Fin.-r ("''' 1ifR'(',C: kt„ �+�F.. p 24.62 BC 25.06 ;'1r I�/�;'11"ly. i`ar,'+•-y-tr�i:i TC 25.40 ' BC 25.00 TC 25.02 � Tc 24.59 BG 24.62 + /� '1 EDGE OF WOODS BC 24.09.59 TC 25.39 TC 25'.26 T---_--- 25.8 rC 25' BCBC -- T=T--- ----jam r BC 25.43 26.16 � Bc z5.z4E ELECTRIC LINE TC 24.33 E1 .. 145.07 ___ N �_ ec 23.83 I 21 30' E �...- ��a4".5 „T_ rc T TELEPHONE LINE N • 0 �.�' o o v N + 4 O E r��_ SC 25.87 24.3 �„�•�•�-�-- NN 0 NN 25'5 '02•,2, r� OO STRUCTURE - SANITARY TC 24.12 C U U + _ BC 23.62 UU N r-(D t-m + L P• / \ 25.9 __ 25 9 C TRANSFORMER ° CLEAN OUT 26.0 ' >- 3 25.9 0.3'E O TELEPHONE CONTROL BOX OF SLOPE �� 3 L.P. ON ' Tp/i 27.7 w \ / F.F. EL. FINISHED FLOOR ELEVATION to 902.00' NN /8.5 v RIM 1 \ MONUMENT OUND W G.F. EL. GARAGE FLOOR ELEVATION ti m j 1 25S.41 ` / �F, 26.0 F0.4 S 27.3 O S.T. O Z TC 55.00/ + 23.9 h / BC 54.50 TOP/BOTTOM OF CURB 23.3 `°� to �� 2502 /� I +55.43 SPOT ELEVATION NN) 25.23 O , ' I ELECTRIC CONTROL BOX LU- U U g 23.4 ' ~� TC 24.55 TC 24.77 O LIGHT POLE (n � f r0E OF / �7 BC 24.35 BC 24.57 + 25.3c - W ' 25.8 SLOPe 24 s zs.4 E CABLE TV CONTROL BOX (t1 22.8 �l TC 24.55 24.9 25.0 A BC 24.25 TC 24.86 _ 24.7 (15 25.2 trin BC 24.66 c° 16.3' ELECTRIC ' NN 13 38.1' ^'i F.F. EL M METER 23.0 Q U U 26.76 in �Lj 'D W- 20.1' ' + 00 R� N 01 Q L0 25.7 In NOTES' ' 24.21 24 86 2 U O RIDGE EL 49.27 n A 0 1. THIS SURVEY WAS PREPARED FOR A SPECIFIC PURPOSE, AND IS NOT ' U 2 STORY INTENDED TO BE USED FOR A TRANSFER OF TITLE OR ANY FINANCIAL TC 23.95 to DWELLING 177 PURPOSE. O BC 23.70 TC 24.75 NO. 1075 49.3' BC 24.50 23'1 2. THIS SURVEY WAS PREPARED WITHOUT BENEFIT OF A TITLE REPORT AND J + 25.06 RIDGE EL 56.43 + THEREFORE, THE EXISTENCE OF ANY COVENANTS, RESTRICTIONS, 24.8 24.1 W + H A/C I EASEMENTS AND/OR RIGHTS OF WAY OF RECORD, IF ANY, ARE NOT + 23.6 TC 24.75 n UNIT SHOWN OR ADDRESSED. 22.7 W + BC 24.55 N a.s' 9 3. PROPERTY CORNER MONUMENTS WERE NOT PLACED AS PART OF THIS O �' 24.1 --------------- Te.� IA/C SURVEY. Ix a F.F. EL 4. SUBSURFACE AND ENVIRONMENTAL CONDITIONS WERE NOT EXAMINED OR O z TC 24.65 1 STORY 26730 24'5 CONSIDERED AS PART OF THIS SURVEY. SC 24.35 15.1' d DECK ~ � 24.1 \ O 5. THE OFFSETS OR DIMENSIONS SHOWN FROM THE STRUCTURES TO THE PROPERTY LINES ARE FOR A SPECIFIC PURPOSE AND USE AND 2 21.4 " 15.3' THEREFORE ARE NOT INTENDED TO GUIDE IN THE ERECTION OF FENCES, 24.4 ' RETAINING WALLS, POOLS, PATIOS, PLANTING AREAS, ADDITIONS TO 0 23 5 23.4 24.6 23 O ' BUILDINGS OR ANY OTHER CONSTRUCTION. Q + 23.7 6. THE LOCATIONS OF UNDERGROUND UTILITIES SHOWN ARE BASED ON J Of-,- GA TE 22.4 VISIBLE ABOVE GROUND STRUCTURES AND MARKOUT BY OTHERS. 10.3's ' p 0- 0� + LOCATIONS OF UNDERGROUND UTILITIES/STRUCTURES MAY VARY FROM O O 22.6 -+- JZ LOCATIONS SHOWN HEREON. ADDITIONAL BURIED UTILITIES AND O �_' ---__ GAT 23.98 22.9 tJ STRUCTURES MAY BE ENCOUNTERED. _ 0 OE 0 7. LOCATIONS OF WELL, WATER LINE, SANITARY STRUCTURES, AND I a 2 5 M SANITARY LINE ARE PROVIDED BY OTHERS. 27'24 11) o + 0 8. THE PROPERTY APPEARS AS LOT 81 ON THE MAP OF HARBOR LIGHTS M 21.3002126 ' to 9. SECTION FOUR, FILED MARCH 1, 1984 - MAP No. 7703. 21.5 I M 27 32 I O 0 9. LOT AREA = 42,082 SQUARE FEET. 21.29^ I V/ ' s' 10.ELEVATIONS SHOWN HEREON REFER TO N.A.V.D. 1988. to 2 = N O 6.2' O I I INGROUND POOL 21.2 + 21.5 + 21.0 21.2.9 21.1 1119.7 4 O O I I ' 3731 + 21, 3/20/22 A.V.R. FINAL SURVEY 30 20.7 Date By Revision ' 0 O Surveyed by: C.S. Drafted by: A.V.R. Checked by: C.W. FE p X112 CONC 20.2 EXWELILG MONUMENT 11.E 21.0 0.6'N 5.0'E 1.2'E 19.0 O N ----__O-�-O--�_0----- - -- - MAP LINE - -- !- -- -- - - Barrett. S 26024'00" W POOL Q 248.87 Bonaccl & LINE O per- EQUIPMENT O O�--O� 2�52FE 19.3 O-- O-- -_O9.9•E 18.7 _ + 20 D Van Weele, PC 19.1+ 9.8'E '9.8 + Engineers Surveyors Planners LAND NOW OR FORMERLY OF F. & H. REESE 19.3 175A Commerce Drive Hauppauge,NY 11788 T 631.435.1111 F 631.435.1022 18.4 www.bbvpc.com 18.5 19.' 18.7 Tax Map: DISTRICT 1000 SECTION 79 BLOCK 4 LOT 17.5 Ce'Ucalions indicated hereon signify Ihat'ha p!at of the property depicted hereon was made PROPERTY n accooance with the ex sing Code of Pract- for Land Surveyors adopted by the New York SITUATE Stcte Assoactioi of P,ofessional Land Surveyors This cerrdreanan is only for the lands depicted SANITARY LOCATION TIES here and is not cof title,zanmg or SOUTHOLD Leadcm of encumbbranranceses Said certifications shall run on'y to tlia persons and/or entities SANITARY listed hereon and are not transferable to add TOWN OF SOUTHOLD SUFFOLK COUNTY,N.Y. STRUCTURE BUILDING CORNER anal persons,entuesorsubsequentown rs 1 S.T. 2' 8' Una�nharrzed alteration or adduian to s r BOUNDARY & Satvey r Educationci of section 7209 of .k TOPOGRAPHIC SURVEY 2 L.P. 42' 58 State Education Law 3 L.P. 31' 62 Copies of this survey map not bearing the land survayor's embossed seal and signatxe shall not be considered to be a I ue ano valid copy © 2021 BBV PC LM: TOPO Date Scale Project No. Sheet No. O� VIEW: TOPO MAY 15,2021 1"= 20' A210324A TE5T HOLE MCDONALD GE05CIENCE zies b r n DATED: 04 MAY. 2021 X 6\/F- 2aee X L,P P�R K { k OCT 0 1 2021 �L. 25.3 IJARK BROWN LOAM UL to-re j 24 6e 24.62 BROWN 51LTY 5AND SM R z j- - _ - N 3734'So.r E BUILDING DEPT. 3.0' "r in 10Z 72' TOWN OF SOUTHOLO 45.07,il (2i LaCr!:NG PO L --- BROWN FINE TO MEDIUM 5AND 5P - � ® N 21•3p'00" E. 2;4LP E DIA.,d-ao P k _�-� r �-\ _ 286 7.0' 24,3 _��-' _x k ,EX f _ LP PALE.BROWN FINE 5AND 5P j( _I 20.0 } 28.0 JNUMENT ' 1 500 GA,LOI IT .`OUND x > 5EPT,C rANC n-r•.) q m 5EP71C TAN< ST Ai D a5 At, r LEACOING POO_TO BE 1� I ( k'i� � Ffl ED y�ABaNDO1+ED rS7''S 2�1J * 27J ;EST no E F \�m � azs I LOT 80 BROWN FINE TO COAR5E 5AND 5W 24- Locar;oN o L J 1 n X I i U ( - 3a 214 I 9 '_0"'MPR'JVED 23's I CLEA OUT TO 5E LOCATED ( EL. 4-8.3 17.0' n APPRO% 1'-O'PRo-"A 24,7 w .•ISTING STRU(TJL. 2 2SU N 120.7 n 23.4 24.6 0 18.J' ?.KOPijiEr`�-->,;OE OF 5LOPe �r " / Q o�",�:i NO WATER ENCOUNTERED DRAINAGE CALCU TIONS: Y _- - ZONE 1: 259 51' 0.17 = 44.1 CF 2Ze 2118 GARAGE F F.EL �` G` ft 2G 76 PROM DE(1)G'DIA x 3'-G'O DRYWELL(78.2 CF) " t(0 1 k 2531 � 1 24.21 24X.°8 U _ 'xs O G RIDGE SI• 24,0 2C7 O Dv.LL•vG EL 1 'Z 1 NO 30.5 SG.43 t7 w c_n�ry�to et 1500 GALLON !2)LEACHING POOL `s' < W U I 2&06d re,t+Ex51•NG i-C z 8'�1A.x 8-0'DF PSEPTI_-TANK(TYP.)Al _ K ? 1 QI O -,4L;�TpRt � 337.d CE :.AG, C UNIT p I X aO 575.6 CE ICTAL X e e to 7 '.-8 1/2" I MINIMUM 220'DIAME ue TER 24.8 G 5 4 24.1 3 -1 1 GRADE EL:+24.9• COVERED OPENING GRADE EL.+25.3' 5 22.7 d r-SrORr b E%15TING I co b a•DtAMEiE2 APPROVED I O w I t51 f DECt I 10 5C ,PIPING(YP.) 4'DTAM TER APPROVED 1 Z a 24, N 14J• % D 1 W PIPE I.E. SEWER PIPING(NP) n 1 k k < 4,4 24.8 23.0 73.7PIPE I E. `•E LE PIPE:°: Y ,r \` 5LOPE.I.1 T•MIN. �'� 1 1 21.5 21,0' 23.4 X 5LOPE:%J 1'M.N. k F\ '�6 5LOPE: I G'164' OUTLET TO BE G' 2t.4 I % I LOWER THAN INLET k 1 SLOPE: :'1 6 1 23.8 X X \ EFFECTIVE UOUID CR0550VER lip,9 y'.4 u-° J ti Q1v DEPTtt 5..0. . 2MW 5" 1 �G\ •) _�O 4'MIN' POUR50 CONCRETE 50:13 EFrEC7:VE �; • DEP"1 7-0' ri'- baeilVt M -.0.5.E1.Ev. 1 21X.8 k 21'24 21.28 `\t ` 04 501-TOM OPEN TO 5AND M I ER UN; 21-32 "' LOT 81 �� �ra 1 SEPTIC CKO55-SECTION GOM3'-J'A50VE 1 2126 ` ROUND:".'At n M 21.0 1\ I NOT TO5CALE ___________ _ tq I e k 21.0 5 BEDROOM T1OJ5E:MINIMJM 1 500 GALLON 5EPTIC TANY. 21.2 I TES',MOLE tNDTCATES EU +5.31 EXISTING NO GROUNDWATER ENCOUNTE-RfD INGROUNp POOL 2116 MONU"nENT 1 AT EL: +(i.3' 21.8 'OUND (17.0'BELOW C-RAOE) 1 1 " EX15TING ul 0 6:N LOC41:014 23. I 2117 _ 21.12 KELLEHER r G0%C _ --- 248.87' ,e.7 21.0 _j1- NAP LINE _-_-------- s 26-24'00" wE��°OE' pO 52 .O SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TERRENCE AND MARGARET 19A ,k ,k PERMIT FOR APPROVAL OF CONSTRUCTION FORA I075 CLIPPER DRIVE SOUTHOLD, NY 11971l6. LANE)NOwOROVACAL�OFF : „ REESE SINGLE FAMILY RESIDENCE Of�LY 12 AUGUST LoT,VACANT , aoai REVISED 10.7 SCALE:1" =30'-0" ,e me DATE 9/16/2021S. REF. RIO. R-21-2326 Robert I. Brown BASED ON SURVEY BY: Architect, P.C. SITE PLAN APPROVED ��'-��`��- BARRETT, BONACCI, � VAN WEELE P.C. s z05 Ball Ave. Greenport NY SCALE: 1 " = 30'-0" DATED: 15 MAY 2021 FOR MAXIMUM F 5 BEDROOMS info@rlbrownarchitect.co) � f, AP;L-"� EXISTING EXCEPT AS NOTEDELEVATIONS SHOWN HEREON REFER TO NAVE) 1988 EXPIRES THREE YEARS FROM DATE OF APPROVAL �3i-477-975 =0ITINA �` I R ol�fn ?, HARBOR LIGHTS HOMEOWNERS ASSOCIAI ION UNLSSACTIN ItNDER euwroRANYrrA�` UN l.1'sti ncnr.r,UNDER TI le mnrcnuN ur n-\ LICENSED ARCI IrI'E(T.TO ALITR ANY rFEM ON ' `J '¢(' SCTIVI: 1000 79-4- 17.5 Abandonment of the existing sanitary system must be in TI ITS DRAWING IN ANY WAY.ANYALrutom EU 1` ;•j' DBCRAT10NMUSTRFMUTED,Sri I TI 1•nAD 1 UGSCRIIIL'U IN ACCORDANCE t5'TI'I I TI IE IAN'. ZONED: AC conformance with the Department's requirements. AREA: 42,082 SF (0.94 AC) Submit completed form WWM-080 as proof APPROVED AS NOTED DATE: 3 B.P.# FEE: av COMPLY WITH ALL CODES OF NOTIFY BUILDING- � :RTMENT AT . NEW YORK STATE &TOWN CODES 765-1802 8 A TO PM �R THE NEW 54" BILCO 5TAKWEL AS REQUIRED AND CONDITIONS OF . FOLLOWING INSPECTIONS: EGRESS WINDOW WELL 1 1. FOUNDATION - TWO REQUIRED 4.6 NEW BASEMENT EGRESS WINDOW D FOR POURED CONCRETE ANDERSEN 400 SERIES CXW 145 L.T 2. ROUGH - FRAMING & PLUMBING �3 0# CASEMENT WINDOW STEES 3. INSULATION (2) 2x 10 HEADER 4. FINAL - CONST°1JCTION MUST EQ E I ` E — GRADE SLOPED AWAY BE COMPLETE C.O. WINDOW SILL ALL CONSTRUCTION SHALL MEET TA HEIGHT TO BE REQUIREMENTS OF THE CODES OF N LESS THAN 44 ABOVE FLOOR NEW BASEMENT EGRESS WINDOW YORK STATE. NOT RESPONSIBLE F _ -_�_ _ ANDERSEN 400 SERIES CXW 145 NEW 54" BILCO STAKWEL EGRESS DESIGN OR CONSTRUCTION ERROf IS - CASEMENT WINDOW N WINDOW WELL 12'-1 1" WINDOW SILL HEIGHT TO BE LESS THAN 44" - - - ABOVE FLOOR L N 2 23 Q o EX15TING STORAGE EXISTING 181 SF D MECHANICAL 87 5F SECTION DETAIL SCALE: 1/4" = I'-0" EXISTING EXCEPT AS NOTED EXISTING FINISHED BASEMENT Ln 542 SF 29 112° OCCUPANCY OR Blower door - e - - e USE IS UNLAWFUL and ductwork EXISTING GARAGE SLAB WITHOUT CERTIFICATE testing required. N OF OCCUPANCY - KELLEHER GUP Ic A E ELECTRICAL. TERRENCE AND MARGARET INSPECTION REQUIRED 1075 CLIPPER DRIVE SOUTHOLD, NY n971 UP 13. 17 FEBRUARY, 2021 SCALE:1/8"=i'-o" Robert I. Brown Architect, P.C. EO U N D AT I O N P LA N - E I N 1 S H E D D AS E M E N T Additional 205 Bay Ave. Greenport NY Certification into@ribrownarchitect.com ,p ED APO, SCALE: 1/4" = 1'-0" 631-477-9752 �`' R�1.BR��� May Be Required. �2 EXISTING EXCEPT AS NOTED IT IS A VIOLATION OFTHE LAW FOR ANY PERSON, UNLESS ACING UNDER THE DIRECTION OFA .-..I LICENSED ARCHITECT,TO ALTER ANY ITEM ON - THIS DRAWING IN ANY WAY.ANY AUTHORIZED ALTERATION MUST BE NOTED,SEALED,AND DESCRIBED IN ACCORDANCE WITH THE LAW. : , ,5icy- sA 163. ' 1 l v - 12068 OEXI5TING DINING ROOM O tD v 19G 5F EX15TING 5UNROOM 147 5F O 1 - 14'-8" 2868 12068 1 " 4'-0' m 2668 2468 fX15TiNG N LAUNDRY EXISTING EXIS N FIREPLACE AND o BATH O CHIMNEY EX15TING LIVING ROOM 2868 N - 340 5F I EXISTING rJTCHEN 340 5F m m DOWN TO BA5EMENT 4 I I ----------- N EX15TING GARAGE N DOWN 525 5F TO BA5EMENTN N N EX15TING STUDY - 160 5F a EX15TING FOYER o 135 5F 13'-2' 21'-6 1/2' i LIP KELLEHER TERRENCE AND MARGARET 1075 CLIPPER DRIVE SOUTHOLD, NY ug7i 2'-1 1 1 G'-1 3/4" 9 7'-1 O 1/4' 5G'-I 1' 17 FEBRUARY, 2021 SCALE:1/8"=i'-o" Robert I. Brown f I RST f LOOK PLAN Architect, P.C. SCALE: 1/4" = 1'-0" 20 Bax Ave. Greenport NY EXISTING EXCEPT A5 NOTED into@rlbrownarchitect.com �RG�A y�T 631-477-9752 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A . LICENSED ARCHITECT,TO ALTER ANY ITEM ON .` I THIS DRAWING IN ANY WAY.ANY AUTHORIZED } 4t' ALTERATION MUST BE NOTED,SEALED,AND }=q . DESCRIBED IN ACCORDANCE WITH THE LAW. \ 17-10" / 12'-0 1/2• 16'-3° \ / EX15TING BEDROOM — \ / \ J 185 SF m EX15TING MASTER BEDROOM EX15TING \\J/ - 258 5F FIREPLACE AND - /\ CHIMNEY JOPEN TO BELO�\ 868 / \ 2668 a / \ ISTING MA57E BATH / \ EXISTING GLOSET cn /• \\ �'� EXISTING CLOSET oD 2668 DOWN 2668 u 0 // w EX15TING BEDROOM "cv OPE�;1-�O BELOW EX15TING BATHROOM J \ \ '\\j , o KELLEHER TERRENCE AND MARGARET 2'-1 1• 16'-1 3/4• 37'-10• 1075 CLIPPER DRIVE SOUTHOLD, NY n97i 5G'-l 1° 17 FEBRUARY, 2021 SCALE:1/8"=i'-d' S ECO N D FLOOK PLAN Robert I. Brown Architect, P.C. SCALE: 114" = 1'-0" 2o5 Bay Ave. Greenport NY EXISTING EXCEPT AS NOTED in?o@ribrownarchitect.com DAR 3 477-975 R p IT IS A VIOLATION OF THE LAW FOR ANY PE i{ UNLESS ACTING UNDER THE DIRECTION OFA - LICENSED ARCHITECT,TO ALTER ANY ITEM ON THIS DRAWING IN ANY WAY.ANY AUTHORIZED ALTERATION MUST BE NOTED,SEALED,AND - DESCRIBED IN ACCORDANCE WITH THE IAW. t 634 FO s ISSUES/REVISIONS RESIDENTIAL GENERAL NOTES FROM TABLE N 1 102. 1 .2 (R402. 1 .2) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT MISC. GENERAL NOTES CLIMATIC AND GEOGRAPHIC CRITERIA 1.THIS PROJECT 15 THE CONSTRUCTION OF A TWO STORY ADDITION TO AN EXISTING TWO STORY GROUND SNOW LOAD 20 P5F (PER FIG. 1608.2 BCNY5 2020 SINGLE FAMILY RESIDENCE,ZONED AS AC. WIND 5PEED(ULTIMATE DESIGN) 130 MPH (PER FIG. 1609.3(1)13CNY5 2020 2.THE EXISTING HEIGHT OF THE STRUCTURE AS DEFINED BY THE BUILDING CODE of NEW YORK STATE SEISMIC DESIGN CATAGORY B (PER SECT. 1613 BCNY5 2020 2020 I5 30'-3".THE PROPOSED WORK WILL NOT EXCEED THE EXISTING HEIGHT. WINTER DESIGN TEMP I I°F (PER TABLE N 1 101.2) CLIMATE FENESTRATION SKYLIGHT GLAZED CEILING WOOD FRAME MASS WALL FLOOR BASEMENT SLAB CRAWL 3.THE TYPE OF CONSTRUCTION 15 TYPE V(B). FLOOD ZONE N/A (PER FEMA MAP) ZONE LI-FACTOR, 5 U-FACTOR FENWALL R-VALUE SPACE WALL HGC IN R-VALUE WALL R-VALUE R-VALULU E R-VAE 4.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2020 BUILDING CODE of NEW YORK FR05T LINE DEPTH 3 R-VALUE DEPTH R-VALUE 6" HGC �.! 17CTRICAL WEATHERING PROBABILITY SEVERE (PER 13CNY5 2020 STATE,2020 EXISTING BUILDING CODE of NEW YORK STATE,AND THE AF t PA WOOD FRAME DESIGN LOAD CALCULATIONS (UNIFORM LIVE LOADS) 4 0.32 0.55" 1 0.40 1 49 20 OR 13+5 8/ 13 19 10/ 13 10, 2FT 10/ 13 I = 110N REQUIRED CONSTRUCTION MANUAL 2015 HIGH WIND EDITION. 5.DE51GN LOAD CALCULATION ARE BASED ON: PER TABLE 1607.1 BCNY5 2020 LIVE LOAD:AS PER TABLE 8301.4,BUILDING CODE of NEW YORK STATE 2020. ROOMS OTHER THAN SLEEPING 40 P51 DEAD LOAD:CALCULATED AS PER R301.3 AS PER 13CNY5 2020. SLEEPING ROOMS 30 P51 0 P51 SNOW LOAD:20 P51 GROUND SNOW LOAD(AS PER FIG.8301.2(5)B1 CNYS 2020. ATTICS WITH LIMITED STORAGE WIND EXPOSURE CATEGORY"C',FOR 130 MPH 3 SECOND GUST. ATTICS WITHOUT STORAGE I O P51 STAIRS 40 P51 LOCATION LIVE DEAD DELECT LIMIT 15T.FL. 40 L.B. 12 U360 2ND.FL.(SLEEP AREA) 30 LB. 12 U360 NAILING SCHEDULE ATTIC(NON STORAGE) 20 LB. 10 U360 (PER AF*PA AMERICAN WOOD COUNCIL WFCM FOR Blower door ROOF 20 LB. 15 L/3GO ONE AND TWO FAMILY DWELLINGS 2015 513C HIGH WIND EDITION) JOINT DESCRIPTION NUMBER OF COMMON NAILS NAIL SPACING and ductwork 6.THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE CONSTRUCTION M`AN5,METHODS, TECHNIQUES,SEQUENCES,OR PROCEDURES,OR FOR SAFETY PRECAUTION5AND PROGRAMS IN ROOF FRAMING CONNECTION WITH THE WORK. RAFTER TO TOP PLATE(TOE-NAILED) 3 PER RAFTER �'stin required. THERE APE NO WARRANTIES,NOR ANY MERCHANTIBILITY OF FITNESS FOR A SPECIFIC USE EXPRESSED CEILING J015T TO TOP PLATE(TOE-NAILED) 3 PER J015T OR IMPLIED IN THE USE OF THESE PLANS. CEILING JOIST TO PARALLEL RAFTER(FACE-NAILED) 3 EACH LAP 7.CONTRACTOR TO VERIFY ALL DIMEN51ON5 BEFORE STARTING CONSTRUCTION.DO NOT SCALE CEILING JOIST LAPS OVER PARTITION((FACE-NAILED) 3 EACH LAP RIDGE STRAP(EACH END) 2 PER TIE DRAWINGS.FOLLOW DIMENSIONS ONLY. 8.CONTRACTOR(5)SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT SHOWN,LISTED,OR BLOCKING TO RAFTER (END NAILS 2-8d EACH END DESCRIBED ON THESE DRAWINGS SUBJECT TO QUALIFICATIONS,CONDITIONS,OR EXCEPTIONS AS RIM BOARD TO RAFTER(END-NAILED) 2-16d EACH END WALL FRAMING Must Provide Manuals NOTED.CONTRACTOR SHALL FURNISH ALL LABOR,SCAFFOLDING,AND TOOTS NECE55ARYTO COMPLETE THE WORK, TOP PLATE TO TOP PLATE(FACE-NAILED) 2-16d PER FOOT 9.ALL MATERIAL SHALL BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURES REQUIREMENTS TOP PLATES INTERSECTIONS(FACE-NAILED) 4-16d JOIST EA.SIDE D STUD TO STUDD(FACE-NAILED) 2-I 6d 24"O.C. � J and S as per AND SPECIFICATIONS. HEADER TO HEADER(FACE-NAILED) I Gd I G'O.C.ALONG EDGES NYS Energy Code 10.CONTRACTOR SHALL OBTAIN ALL REQUIRED INSPECTIONS,APPROVALS AND CERTIFICATE OF TOP OR BOTTOM PLATE TO STUD(END-NAILED) 2-1 Gd,3-I Gd,4-1 Gd PER 2x4,2xG,2x8 RESPECTIVELY OCCUPANCY. BOTTOM PLATE TO FLOOR JOIST,BAND JOIST, DEMOLITION END J015T OR BLOCKING(FACE-NAILED) 2-I Gd PER FOOT 1.CONTRACTOR SHALL DEMOLISH WAILS,FLOOR, AND EXISTING ROOF AS INDICATED ON DRAWINGS AND FLOOR FRAMING AS NECESSARY,AND REMOVE DEBRIS. J015T TO SILL,TOP PLATE TO GIRDER(TOE-NAILED) 4-8d PER JOIST 2.CONTRACTOR SHALL DO ALL PATCHING REQUIRED DUE TO REMOVAL OF EXISTING WORK AND OR BRIDGING TO J015T(TOE-NAILED) 2$d EACH END INSTALLATION OF NEW WORK. BLOCKING TO J015T(TOE-NAILED) 2-8d EACH END 3.ALL NEW WORK SHALL MATCH AND MEET FLUSH TO EXISTING WORK AS CLOSELY AS POSSIBLE UNLESS BLOCKING TO SILL OR TOP PLATE(FACE-NAILED) 3-I Gd EACH BLOCK J OTHERWISE NOTED. LEDGE STRIP TO BEAM(FACE-NAILED) 3-I Gd EACH JOIST X y 4. EX15TING STRUCTURE AND INTERIORS TO REMAIN SHALLBE PROTECTED AS NECESSARY DURING JOIST ON LEDGE TO BEAM(TOE-NAILED)D) 3 Sd PER JOIST 25 65 p DEMOLITION AND CONSTRUCTION. BAND J015T TO JOIST(END-NAILED) 3-I Gd PER J015T S OHO k 5. CONTRACTOR SHALL PROTECT EXISTING SERVICES TO REMAIN AND SHALL NOTIFY ALL UTIUTIE5 AND BAND J015T TO SILL OR TOP PLATE(TOE-NAILED) 2-16d PER FOOT TELEPHONE SERVICES AND MAKE ARRANGEMENTS FOR HOOK-UP,REMOVAL,OR CAPPING OF EQUIPMENT ROOF SHEATHING 23.86 AS NECESSARY. STRUCURAL PANEIJ5 8d (TABLE 3.8) 25 31 D R I v z + DIAGONAL BOARD SHEATHING k CUP P E R \ 26.16 FOUNDATIONS I NG"OK Px8" 2-8d PEP 5UPPOKT 2498 C 1.ASSUMED 501L BEARING CAPACITY, 1,500 IW 5,I.Ft. I"x 10"OR WIDER 3-8d PER SUPPORT 24.92 2.CONCRETE TO BE PLAIN,REINFORCED,3,000 psi.-28 DAY TEST. 3.ALL NEW FOOTINGS TO REST ON UNDISTURBED SOIL. CEILING SHEATHING k N 37,34'50" E- GYPSUM WALLBOARD 5d coolers 7"EDGE/10"FIELD 24.62 GENERAL CONSTRUCTION WALL SHEATHING __ 1.PROVIDE ALL LABOR,MATERIALS,TRANSPORTATION,EQUIPMENT AND 5ERVICE5 NECE55ARYTO STIR PANEL 8d (TABLE 3.9) _ 1_ _ 102.721 COMPLETE ALL WOOD AND PLASTIC WORK REQUIRED BY THE DRAWINGS AS SPECIFIED HEREIN,OR FIBERBOARD PANELS 145•�� REASONABLY IMPLIED AS NECESSARY TO COMPLETE THE WORK. �-' (2)LEACHING PO L 2.FASCIAS,SOFFITS AND EXTERIOR TRIM SHALL MATCH EXISTING. 7/1 6' 8d 3-EDGE/6'FIELD 1,00" E -�� 25/32" 8d 3'EDGE/G'FIELD 2�'-3 -��- Id 25.4 LP 8'DIA.x 8'-O DE P 3.INTERIOR TRIM SHALL MATCH EXISTING. N _ 4.FRAMING ELEMENTS: GYPSUM WALLBOARD Sd coolers 7-EDGE/1 O'FIELD � .�""' N �\ � 25.9 A.ALL FRAMING LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR-LARCH STRUCTURAL GRADE NO.2 HARDBOARD 8d (TABU 3.9) r�- ' X OR BETTER. PAPTICALBOAPD PANELS 8d (TABLE 3.9) 24.3 _ I-/� LP B.ALL ENGINEERED LUMBER SHALL BE AS INDICATED ON DRAWINGS,AND SHALL BE INSTALLED,CUT DIAGONAL BOARD SHEATHING I 26.0 >_ \ \ - 26 ;.0 ONUMENT AND DRILLED IN ACCORDANCE WITH MANUFACTURERS REQUIREMENTS AND SPECIFICATIONS. I kG"OR 1"x8" 2-8d PER SUPPORT I !_ w 1500 GALLO ° FOUND C.ALL SHEATHING TO BE APA RATED,EXPOSURE 1,THICKNESS AS INDICATED. I'x 10"OR WIDER 3-8d PER SUPPORT SEPTIC TANK M(F.) ST m D.ALL SUB FLOORING TO BE APA RATED 5TURD-I-FLOOR,EXP05UPE I,3/4"MIN.THICKNE5. I 1 ��,7 7 EX TING SEPTIC TANK NF/ L 0.4'S E.ALL HEADERS G'-0"AND OVER SHALL BE SUPPORTED WITH DOUBLE UPRIGHTS,9'-0"AND OVER FLOOR SHEATHING A LEACHING POOL TO BE Ghgo WITH TRIPLE UPRIGHTS.ALL HEADERS SHALL BE A MIN.OF(2)2"x8"OR AS SHOWN ON DRAWING. 5TRUCURAL PANELS I I 'k i j FI ED jNQABANDONED X/�!ZS F.SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS AND FLOOR BEAMS AS PER BCNYS 2020 I.OR LE55 8d 6"EDGE/ 12'FIELD I CZE OR AS NOTED @ 8'-0'O.C.MIN..PROVIDE 2"SPACE FOR AIR CIRCULATION IN ROOF. GREATER THAN P I Od G-EDGE/6'FIELD I I / i 28 5 O G.PROVIDE DOUBLE FRAMING AROUND ALL OPENINGS(STAIRS,ETC.)OR AS NOTED ON DRAWINGS. DIAGONAL BOARD SHEATHING ` 5.23 TEST HOLE 5.02 H.PROVIDE DOUBTS UP FRAMING UNDER ALL POSTS AND PARALLEL PARTITIONS ORAS NOTED ON 1'x6"OR 1'x8" 2-8d PER SUPPORT 27.3 � L_.I DRAWING. I'x 101 OR WIDER 3-8d PER SUPPORT 24.9 LOCATION LOT 80 i � I.ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED WITH RATED GALVANIZED METAL CONNECTORS BY"51MP5ON'OR APPROVED EQUAL. 23 3 I I Z I _ 5.39 k i LOT IMPROVEDJ.NAILING SCHEDULE SHALL BE A5 PER BUILDING CODE of NEW YORK STATE 2020 AS A MINIMUM. IICLEA OUT TO BE LOCATED 1 25.4 pp 28 MAY,2021 ALL 2'x6'STUDS SHALL RECEIVE(5) 1 Od NAIL5 AT SILL AND PLATE,ALL EXTERIOR NAILS SHALL BE APPROX. I'-0"FROM - GALVANIZED. SEE ATTACHED NAILING SCHEDULE. I „k X 2 ,g N I X e- 11 FEBUARY,2021 AS BUILT K.PLYWOOD SHEATHING TO 8E NAILED 8d NAILS @ 4'O.C.EXTERIOR EDGES AND 6d NAILS @ 12' w ISTING STRUCTURE 2 i- „ 25.7 O.C.INTERMEDIATE. SEE ATTACHED NAILING SCHEDULE. W 23 '' 24 7 24.9 n 16'3 25 O 2 O PROPOSE L.ALL INTERIOR AND EXTERIOR FINISHES TO BE SELECTED BY OWNER. W TOE OF SLOPE 381• �/ _� DRYWELL DRAINAGE CALCI TIONS: M.ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE AND STUD WITH GALVANIZED HURRICANE W I 25.8 TYPE CONNECTORS BY'51MP50N"OR APPROVED EQUAL.FOR TIMBER PILE FOUNDATIONS,PROVIDE I� 5� - ZONE 1 : 259 5F 0. 17 = 44. 1 CF HURRICANE CUPS AT ALL PERIMETER JOISTS TO GIRDER CONNECTIONS. 22 8 [} 25.2 Vj GARAGE F.F. EL / ti = I �, 1501TI / 5.ALL NEW WINDOWS TO BE THERMAL INSULATED LOW-E GLASS,WITH ARGON GAS,IMPACT RESISTANT AS G.F. EL 26,71, THESE PLANS ARE AN INSTRUMENT OF SERVICE �+ � 1 X � � PROV DE (I) 6 DIA x 3-6 D DRYWELL (780 .2 GF) REQUIRED. X 25.3 I AND ARE THE PROPERTY OF THE ARCHITECT. ( . G.LOAD PATHS APE INDICATED BY SECTION DRAWINGS. IL �- I 24.2+ 24.66 z EXISTING 3.r 24.5 INFRINGEMENTS WILL BE PROSECUTED �' O b, RIDGE 24.7 7.CONNECTIONS SHALL BE BUILT IN ACCORDANCE WITH ANSI/AF/t PA WCFM-1995.(SEE NAILING 1,-� �� � LL V N 2-STORY SCHEDULE) O "' DWELLING EL I 2021 ALL RIGHTS RESERVED 8.FLASHING AT ALL WINDOW AND DOOR OPENINGS SHALL BE EPDM OR APPROVED RUBBERIZED L 56.43 MEMBRANE. J z NO. 1075 I LLI 9.FLASHING AT ROOF CONNECTIONS,VALLEYS,CHIMNEYS AND CRICKETS SHALL BE ALUMINUM. W U I 25.06 N 10.STEP FLASHING SHALL BE USED AT ALL INTERSECTIONS OF SLOPED AND VERTICAL SURFACES,EXCEPT STEP FLASHING AND COUNTER-AND CAP-FLASHING SHALL BE USED AT INTERSECTION OF ROOF AND I ,, ,y Al I CHIMNEY,AND ROOF AND WALLS. ~ I u 1 1.INSULATION SHALL BE BATT INSULATION OF THICKNE55 INDICATED ON THE DRAWINGS AND SHALL BE CORNER � N 8.6 ,8.7 ' O k X UNIT � � 24.8 X1 � 65'-8 I/2" � 2-1/2 Ib. DENSITY FIBER-GLA55 BATT5 CONFORMING TO THE SPECIfiCATION5 FOR PRE-FORMED FIBROUS 23.6 GLA55 INSULATION.NAAMM STANDARD 51, 1 b-70. CLOSED-CELL SPRAY-IN FOAM INSULATION(R-G.5 PER Q X I 5 INCH)BY ICYNENE OR APPROVED EQUAL SHALL BE PROVIDED AS INDICATED ON DRAWINGS. H OLDDOWN ` I Robert 1. Brown 22.7 o I-STORY o EXISTING � � I 00 12.NEW INTERIOR DOORS SHALL MATCH EXISTING. 3 13. NEW HARDWARE SHALL MATCH EXISTING. W 15,1• DECK ZI ' 14.GYPSUM BOARD SHALL BE EASED EDGE TYPE,CONFORMING TO A5TM C3G,AND SHALL B24. E z 15.3• '? Architect, P.C. Q J 1 � k k '5HEETROCK SW` Y U.S.GYPSUM CO.OR APPROVED EQUAL. GYPSUM WALLBOARDrj THICKNESS SHALL BE I 15 tl4 4 24.6 23.0 23 ALL NEW AND REPAIRED GYP.BOARD SHALL BE TAPED AND 5PACKLED THREE(3)COATS.ALL EXTERIOR 7 CORNERS SHALL HAVE METAL CORNER BEADS. aos Bax Ave. Greenport NY 1 23.4 \ 122.9 in o@ribrownarchitect.com FINISHES 1. NEW WOOD FLOORS TO BE SELECTED BY OWNER,SANDED AND POLYURETHANE, / "� J 21.4 I X 3COAT5. / I 4 631-477-9752 23.5 k 2. EXISTING WOOD FLOORS SHALL BE SANDED AND REFINISHED. �- 22 22.6 3. CERAMIC TILE FLOOR SHALL BE SELECTED BY OWNER AND INSTALLED WITH THIN SET 9J I 'tVC ADHESIVE. 23.98 <S 4.EXTERIOR PAINT SHALL BE LATEX ACRYLIC BY BENJAMIN MOORE OR APPROVED ' O EQUAL,APPLIED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS. COLOR To BE SELECTED. \�o IT IS A VIOLATION OF THE LAW FOR ANY PERSON, 5.EXISTING INTERIOR WALLS AND CEILINGS IN ROOMS AFFECTED BX 21.24 Y THE WORK SHALL " " \ X BE CLEANED AND REPAINTED. NEW WALLS AND CEILINGS SHALL BE SEALED AND I I UNLESS ACTING UNDER THE DIRECTION OF A PAINTED.PAINTING SHALL D TWO W COATS BENJAMIN MOORS AQUA PEARL LATEX RIDGE CROSS SECTION END VIEW 21.5 X 21.28 \ O2� LICENSED ARCHITECT,TO ALTER ANY ITEM ON O PAINTED,COLOR TO BE SELECTED. 21.3 ¢� I THIS DRAWING IN ANYWAY. ANY AUTHORIZED Z` G. INTERIOR TRIM SHALL BE SANDED SMOOTH,PRIMED,AND FINISHED WITH TWO(2) 21.32 LOT 81 1 ALTERATION MUST BE NOTED,SEALED,AND COATS BENJAMIN MOORE LATEX ACRYLIC SEMI-GLOSS PAINT. P7 I 21.29 ? DESCRIBED IN ACCORDANCE WITH THE LAW. HVAC ►� I 21.5 19.7 1.PROVIDE ALL LABOR,MATERIALS,TRANSPORTATION,EQUIPMENT AND SERVICES 8' X 21. 1 NECESSARY TO PROVIDE A HVAC SYSTEM TO HEAT AND COOL THE LIVING SPACES tr) 1 Q X 21.0 err . AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND THE 2020 MECHANICAL W it 21'2 t.{t At ' CODE of NEW YORK STATE,OR REASONABLY IMPLIED AS NECESSARY TO COMPLETE I Z EXISTING 2 EXITO SRK.TING BOILER TO REMAIN. ° 215 INGROUND POOL k FOUND %\<y ' z N °. 21.29 MONUMENT 3.EXISTING AIR HANDLERS AND CONDITIONERS TO REMAIN. u , u EXISTING WELL O.G'N -2 37-2 _ 4.PROVIDE AIR-HANDLERS,DUCTWORK,AND CONTROLS AS NECE55APYT0 I t LOCATION COMPLETE THE WORK FOR AIR CONDITIONING IN ALL ZONES. 5.PROVIDE HOT WATER RADIANT HEAT TUBING AS NECE55APY FOR HEATING IN ALL 1 21.30 ZONES. k - PLUMBING I 207 coNc _ - - - 248.87 117 21-12 20.2 _ , 1.PROVIDE ALL LABOR,MATERIALS,TRANSPORTATION, EQUIPMENT,AND SERVICES MAP LINE _ - NECESSARY TO COMPLETE ALL NEW PLUMBING WORK REQUIRED BY THE DRAWINGS 21.0 - .-r O'E r N G' AND SPECIFICATIONS AND THE 2020 PLUMBING CODE of NEW YORK STATE,OR - 'Q Q�� W POOL REASONABLY IMPLIED AS NECESSARY TO COMPLETE THE WORK. - - S 26'24 EQUIPMENT 20.52 \ 2.CONFORM TO THE NEW YORK STATE ENVIRONMENTAL CONSERVATION LAW WITH 19.0 REGARDS TO WATER SAVING AND CONSERVATION. ALL FIXTURES SHALL BE ON THE 3 20.0 19 3 APPROVED'UST OF CERTIFIED WATER SAVING PLUMBING FIXTURED'A5 PUBLISHED BY THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION. 19.3 CLIENT/OWNER 3. ALLWORK ON THE PLUMBING SYSTEM SHALLBE PERFORMED BY OR UNDER THE " X 19'8 SUPERVISION LL A PROPERLY LICENSED MASTER PLUMBER. UPON COMPLETION,THE X KELLEHER PLUMBER SHALL PROVIDE A SOLDER CERTIFICATE AS REQUIRED BY THE TOWN OF 19.1k LAND NOW OR FORMERLY OF F. � H. REESE SOUTHOLD. 4.THE CONTRACTOR SHALL OBTAIN,SUBMIT,AND PAY FOR ALL PERMITS, LOT VACANT CERTIFICATIONS,LICENSES AND INSPECTIONS A55 REQUIRED BY LOCAL,STATE,AND TERRENCE AND MARGARET FEDERAL AUTHORITIES,AND ANY OTHER APPLICABLE JURISDICTION. 19.1 18 7 ELECTRICAL FLOOR 1e 4 ,8.5 1075 CLIPPER DRIVE 1.FURNISH ALL LABOR,MATERIALS,EQUIPMENT,PLANT,TOOLS,AND SERVICES JOIST NECESSARY AND REQUIRED FOR PROPER AND COMPLETE INSTALLATION OF ALL NEW SOUTHOLD, NEW YORK LL971 ELECTRICAL 5Y5TEM5 AND RELATED WORK INCLUDING,BUT NOT LIMITED TO: - CONNECTIONS TO PREVIOUSLY INSTALLED ELECTRICAL SYSTEMS,WIRING,LIGHTING, / ' SERVICES,FEEDERS,DISTRIBUTION AND PROTECTION EQUIPMENT,CONNECTIONS TO SITE F'LA N BASED ON 5 U RV EY BY: APPLIANCES, GROUNDING,AND ALL INCLUDING ALL CONNECTIONS AND DEVICES WITHIN THE SCOPE OF THE WORK AS SHOWN ON THE APPLICABLE DRAWINGS AND AND 5PCIFICATION5 AND AS NORMALLY SPECIFIED IN THI5 TYPE OF PROJECT AND BARRETT, BON ACC I, * VAN WEE LE P.C. PROJECT TITLE INCLUDING CONNECTIONS TO PREVIOUSLY INSTALLED TRANSFORMERS AND ELECTRICAL D15TRI13UTIONSYSTEMS. SCALE: 1 " = 20'-0" DATED: 15 MAY 2021 ADDITION 2.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2020 BUILDING CODE 3 of NEW YORK STATE,THE NATIONAL ELECTRICAL CODE,NFPA NO,70-2017(NEC), EXISTING EXCEPT A5 NOTED ELEVATIONS 5HOWN HEREON REFER TO NAVD 1988 LOCAL UTILITY STANDARDS,OCCUPATIONAL SAFETY AND HEALTH CAT(OSHA),THE NATIONAL ELECTRICAL MANUFACTURERS'ASSOCIATION(NEMA)AND ANY OTHER APPLICABLE CODES. IN THE EVENT OF CONFLICT,THE MORE STRINGENT REQUIREMENTS WILL APPLY. ALL PRODUCTS USED FOR ELECTRICAL WORK SHALL BEAR THE UNDERWRITERS LABORATORIES,INC. ABEL AND BE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY FLOOR H! RR O R L I V HT5 H O V EOVN E R5 1550C I 1TIO N WILL BE INSTALLED. JOIST = 4.ALL WORK ON THE ELECTRICAL SYSTEM SHALL BE PERFORMED BY OR UNDER THE 5 CTM: 1000-79-4- 17.5 D WING TITLE SUPERVISION OF A PROPERLY LICENSED MASTER ELECTRICIAN. 5.THE CONTRACTOR SHALL OBTAIN,SUBMIT,AND PAY FOR ALL PERMITS,LICENSES ZONED: AC AND INSPECTIONS AS REQUIRED BY THE LOCAL,STATE,AND FEDERAL AUTHORITIES, SITE PLAN AND ANY OTHER APPLICABLE JURISDICTION. 6.CARBON MONOXIDE DETECTORS IN CONFORMANCE WITH APPLICABLE CODES AREA: 42,082 5F (0.94 AC) SHALL BE CONNECTED TO THE LIGHTING CIRCUITS WITH NO INTERVENING WALL GENERAL NOTES SWITCH. 'LINE CORD-CONNECTED,DIRECT PLUG-IN,AND BATTERY POWERED ALARMS ARE NOT ACCEPTABLE. ALARMS SHALL BE INSTALLED ON EACH LEVEL ON WHICH SLEEPING QUARTERS ARE LOCATED. 7.SMOKE DETECTORS IN CONFORMANCE WITH THE 2020 BUILDING CODE of NEW YORK STATE,THE NFPA NATIONAL FIRE ALARM CODE NO.72-1993 SHALL BE UPLIFT CONNECTIONS 23 SEPTEMBER,2021 PROVIDED OUTSIDE EACH SEPARATE SLEEPING AREA,IN EACH 5PLEEPING AREA,AND SCALE 'r 11 i'=20 ON EACH FLOOR LEVEL. '-0 CONTRACTOR SHALL COORDINATE WITH OWNER'S ALARM COMPANY FOR SMOKE AND CO N N ECTIO N 5 D ETAI L D L I2021IN21 DRAWING NO. BURGLAR ALARMS AS NECESSARY. 0 Bl,U1L 4NG DEPT TOWN 0F SOUTHOLD ISSUES/REVISIONS ---e— — — ---e— — — cfl o EXISTING STORAGE 20 AUGUST,2021 942 5F 28 MAY,2021 EXISTING MECHANICAL 30MARCI I,2021 PRELIMINARY 87 SF C9 0 m THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED — —e— - 2021 ALL RIGHTS RESERVED 8" POURED CONCRETE FOUNDATION WALL REINFORCED w/#5 REBAR IN EACH DIRECTION 10"dia. 50NOTU13E MINIMUM 3'-0" BELOW GRADE ON 8"x I G"CONTINUOUS POURED UNDISTURBED SOIL Robert I• Brown CONCRETE FOOTING 8'-O" EXISTING FINISHED BASEMENT REINFORCED w/#5 REBAR IN 942 SF Architect, P.C. EACH DIRECTION, BURIED MINIMUM 3" IN CONCRETE. MINIMUM 3'-0" BELOW GRADEv 3x8 P.T. LEDGER BOARD RB2o5@ribrownarchitect.com Bax Ave. Greenport NY ON UNDISTURBED 501L m N ANCHORED TO STRUCTURE O. (2) — — — 6inro@ribrownarchitect.com — — — ANCHOR BOLTS EVERY 24"O.C. } s e - - - e — e-- — — — — — 1 VENT w EXISTING GARAGE SLAB .: 12 #5 REBAR ANCHOR BOLT Z SECURED IN EXISTING n- wIT IS A VIOLATION OF THE LAW FOR ANY PERSON, FOUNDATION WALL w/EPDXY U Q cq UNLESS ACTING UNDER THE DIRECTION OF A v @ 12'O.C. VERTICALLY E2(n 10 I LICENSED ARCHITECT,TO ALTER ANY ITEM ON O w�– N THIS DRAWING IN ANY WAY. ANY AUTHORIZED W z NOTED,ALTERATION MUST BE DESCRIBED I ACCORDANC WISEALED,TE LAW. In I N PROPOSED CRAWLSPACE ") I 00 2" POURED CONCRETE RAT SLAB p 12'#5 REBAR ANCHOR BOLT UP TO xC\jSECURED IN EXISTING GARAGE " FOUNDATION WALL w/EPDXY V @ 12'O.C. VERTICALLY i "f L - - - - - - - - VENT UP co co in a in CLIENT/OWNER 20'-0" c KELLEHER FOUNDATION WALL REINFORCED TERRENCE AND MARGARET W/#5 REBAR IN EACH DIRECTION 1075 CLIPPER DRIVE 8'x I G"CONTINUOUS POURED CONCRETE FOOTING UTHOLD, NEW YORK u971 REINFORCED w/#5 REBAR IN FOUNDATION PLAN- EACH DIRECTION, BURIED MINIMUM 3" IN CONCRETE. PROJECT TITLE MINIMUM 3'-0" BELOW GRADE ON UNDISTURBED SOIL SCALE: 1/4' = P-0" EXISTING-A!5 BUILT ADDITION DRAWING TITLE FOUNDATION PLAN SCALE 23 SEPTEMBER,2021 1/4" DRAWING NO. r ISSUES/REVISIONS 12068 EXISTING DINING ROOM 19G SP EXISTING SUNROOM 147 SF 12068 2868 EXISTING LAUNDRY zo AUGUST,2021 EXISTING B THROOM/ 28 MAY,2021 "(:j oO 30 MARCH,2021 PRELIMINARY /� EXISTING LIVING ROOM 340 SP THESE PLANS ARE AN INSTRUMENT OF SERVICE -r-�lr AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED lo 9'-0' 8'-!' i EXISTING KITCHEN zozl ALL RIGHTS RESERVED I 340 SP 3G" HANDRAIL � DOWN TO TO CODE (TW.) BASEMENT Robert I Brown Q 3'-O" DING L--- I Architect, P.C. tj ----------- EXISTING GARAGE Zo5 Bay Ave. Greenport NY NEW ANDERS N 400 SERIES 525 SF inro@rlbrownarchitect.com NEW 2xG EXTERIOR CONSTRUCTION / PWG GOG8 _ cQ 112" CD-X RATED PLYWOOD SHEATHING EO (2) 2x 10 HEADER kD EQ N Z DOWN TO 631-477-9752 VAPOR BARRIOR N BASEMENT 51DING TO MATCH EXISTING Cl w ——————————— °} PROPOSED BEDROOM / G 210 5F IT IS A VIOLATION OF THE LAW FOR ANY PERSON, N w N UNLESS ACTING UNDER THE DIRECTION OF A NEW(2)ANDERSEN 400 SERIES p = LICENSED ARCHITECT,TO ALTER ANY ITEM ON TW 243 10 DOUBLE o w - EXISTING STUDY TI IIS DRAWING IN ANY WAY. ANY AUTHORIZED WHITE/WHITE m ca = co I GO SF ALTERATDESCRIBEID N ACCORDAON MUST BE NCTED,SEALED,AND E WITH THE LAW. x N C9 EXISTING FOYER w135 SF uEFl1 z j (2) ;2x8 HEADER ) (2) ix8 HEADER(TYP.) UP (' -- NEW ANDEP,5E N 400 5ERIE5 NEW ANDERS N 400 5ERIE5 A 21 AWNING WINDOW A 21 AWNING WINDOW WH ITENH ITE WH ITEIWH ITE c� c� v G'-0" 8'-O" G'-0" CLIENT/OWNER 20'-0" KELLEHER TERRENCE AND MARGARET 1075 CLIPPER DRIVE F I f�ST F LO O f� PLAN SOUTHOLD, NEW YORK ng71 SCALE: 1/4" = I'-O' EXISTING-A5 BUILT PROJECT TITLE ADDITION DRAWING TITLE FIRST FLOOR PLAN SCALE 23 SEPTEMBER,2021 1/4"=i-o" DRAWING NO. ISSUES/REVISIONS 20 AUGUST,2021 \ / 28 MAY,2021 \ / EXISTING BEDROOM 30 MARCH,2021 PRELIMINARY \ / 185 SF \ / EXISTING MASTER BEDROOM \ / 258 SF /\ THESE PLANS ARE AN INSTRUMENT OF SERVICE / \ AND ARE THE PROPERTY OF THE ARCHITECT. / \ INFRINGEMENTS WILL BE PROSECUTED / 2021 ALL RIGHTS RESERVED / OPEN TO BELOW \ / \ EXISTING MASTER BATH 91-ON Robert I. Brown NEW(2)ANDS EN 400 SERIES Architect P.C. TW 21041 O DOUBLE HUNG // \\ O(� EGRESS WIND W / \ U WHITE/WHITE Zo5 Bay Ave. Greenport NY -21 / \ f in o@ribrownarchitect.com (2) 2x 10 HEADER 631-477-9752 NEW 2xG EXTERIOR CONSTRUCTION ; 1/2" CD-X RATED PLYWOOD SHEATHING ; VAPOR BARRIOR ; z a SIDING TO MATCH EXISTING ; DOWN PROPOSED BEDROOM IT IS A UNLESS VIOLATION NG OFTDER E LAW FOR ANY CTION OF A PERSON, 221 SF / LICENSED ARCHITECT,TO ALTER ANY ITEM ON CU NEW F OR TO BE LEVEL WITH EXISTING / THIS DRAWING IN ANY WAY. ANY AUTHORIZED 3/4" PLYWOOD SUBFLOOR \ / EXISTING BEDROOM ALTERATION MUST BE NOTED,SEALED,AND O i Q''ff^NNEW W OD FLOORING TO BE SELECTED BY OWNER \ / I GG SF DESCRIBED IN ACCORDANCE WITH THE LAW. m 2'-G 112' / NEWy'SH PAEETROCK ON WALLS AND CEILING TAPE, CKLE, AND PAINT 3 COATSo N OP�KI\ / �J cQ TO BELOW EXISTING BATHROOM w (2) 2x8 HEADER(TYP.) (2) 2x8 HEADER(fYP.) 2'-2' NEW ANDEP,5E N 400 SERIES NEW ANDEP51 N 400 SERIES A 21 AWNING WINDOW A 21 AWNING WINDOW WHITE/WHITE WHITEAMIITE / \ CLIENT/OWNER G'-0" 0_0' 20'-0' KELLEHER TERRENCE AND MARGARET 1 SECOND F LO O 075 CLIPPER DRIVE PLAN SOUTHOLD, NEW YORK u97i SCALE: 114' = I'-0" EXISTING-AS BUILT PROJECT TITLE ADDITION DRAWING TITLE SECOND FLOOR PLAN SCALE 23 SEPTEMBER,2021 1/ i-0" 4��_ DRAWING NO. ISSUES/REVISIONS EX15TING ROOFING TO REMAIN NEW ROOFING TO MATCH EXISTING [11 El \ \ WINDOW SHUTTERS AND TRIM EXISTING ROOFING TO REMAIN TO MATCH EXISTING UL]u ILJILJ L I I—Lil --1 N m NEW 51DING TO MATCH EXISTING N EXISTING SIDING TO REMAIN WINDOW SHUTTERS AND TRIM TO MATCH EXISTING Li 01 EXISTING SIDING TO REMAIN 1L- F- 20'-0" ol NEW CONSTRUCTION zo AUGUST,2021 30 MARCH,2021 NORTH ELEVATION (f[NDU/-'\NT)- SCALE: 114" = I'-O" THESE PLANS ARE AN INSTRUMENT OF SERVICE EXISTING-AS BUILT AND ARF,THE PROPERTY OF THE ARCI IITECT. INFRINGEMENTS WILL BE PROSECUTED 2021 ALL RIGHTS RESERVED Robert I. Brown Architect, P.C. 2o5 Bay Ave. Greenport NY info@ribrownarchitect.com 631-477-9752 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, x RIDGE BEAM NEW 2x8 ROOF RAFTERS UNLESS ACTING UNDER THE DIRECTION OF A REPAIR AND PATCH EXISTING REPAIR AND PATCH EXISTING \� 3/4'CD-X RATED PLYWOOD S EATHING LICENSED ARCHITECT,TO ALTER ANY ITEM ON ROOFING AS NECESSARY VAPOR BARRIOR THIS DRAWING IN ANY WAY. ANY AUTHORIZED ROOFING AS NECESSARY ALTERATION MUST BE NOTED,SEALED,AND NEW ROOF CRICKET 7.5"CLOSED CELL SPRAY-IN FOAM INSULATION (R-50) V.I.F. NEW ROOF PITCH NEW ROOF CRICKET : ROOFING TO MATCH EXISTING DESCRIBED IN ACCORDANCE WITH THE LAW. MINIMUM SLOPE 1/2" Q TO MATCH EXISTING MINIMUM SLOPE 1/2" PER FOOT PER FOOT '-`' $ V.I.F. NEW ROOF hTCH TO MATCH EXISTING ` 2xG CEILING JOISTS SOFFIT AND PJM TO MdNG MATCH NG n J (2) 2x 10 HEADER (2) 2x8 FADER(FYP.) ! Fill`• � o iq c0 �p j CLIENT/OWNER\ NEW SIDING TO MATCH EXISTING , APROPOSED BEDROOM KELLEHER 2x 10 FLOOR JOISTS @ I G"O.C. TERRENCE AND MARGARET (2) 2x 10 HEADER (2) 2x8 t EADER(TYP.) 1075 CLIPPER DRIVE -- SOUTHOLD, NEW YORK 11971 NEW 2xG EXTERIOR CONSTRUCTION Q 1/2"CD-� RATED PLYWOOD SHEATHING PROJECT TITLE A LL=1 �o 0 VAPOR WARRIOR ADDITION - �___.....-_.m__.-_ � �n 2"CLOS�D CELL SPRAY-IN FOAM INSULATION (R-13) R-15 DAFT INSULATION WINDOW SHUTTERS AND TRIM 3'-O" LANDING SIDING TO MATCH EXISTING TO MATCH EXISTING 2x8 P.T. FLOOR PROPOSED BEDROOM JOISTS @ I G"O.C. cD TYMMM 2x 10 FLOOR JOISTS @ I G"O.C. Tmm DRAWING TITLE REAR IL R-22 BATT INSULATION FRONT NEW CRAWL SPACE SECTIONS AND o I O"dia. SONOTUBE MINIMUM 0 8" POURED CONCRETE 3'-0" BELOW GRADE ON FOUNDATION WALL REINFORCED ELEVATIONS 13'-0 1/2" UNDISTURBED SOIL W/#5 U13AR IN EACH DIRECTION NEW CONSTRUCTION 2" RAT SLAB 8"x I G' CONTINUOUS POURED SCALE EAST ELEVATION (51DE) CONCRETE FOOTING 23 SEPTEMBER,2021 1/4"=1'-0" RE BAR EAST ELEVATION (51DE) REACH EINFORCED W/#5 BURIED DRAWING NO. IN SCALE: 1/4" = 1'-0" MINIMUM 3" IO CONCRETE. EXISTING-AS BUILTSCALE: 1/4' = P-0" ON UNDISTURBMINIMUM 3'-0"ED OIL ELOW RADE EXISTING-AS BUILT ISSUES/REVISIONS \ / \ / LEGEND \ / $ LIGHT SWITCH \ / 3 = THREE WAY D = DIMMER \ / ® JAM SWITCH \ / � OUTLET \ / GFI= GROUND FAULT INTEKUPT \ / 220 = 220 VOLT \/ 4 = QUAD OUTLET FIXTURE /\ S= SURFACE MOUNT PROVIDED BY OWNER / \ R= RECESSED PROVIDED BY CONTRACTOR / \ F0 WALL SCONCE 20 AUGUST,2021 OPEN TO BELOW\\ PHONE 30 MARCH,2021 O- CABLE / \ 5E NETWORK CABLE EMERGENCY / \ Q SPEAKERS LIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE / AND ARE THE PROPERTY OF THE ARCHITECT.\ ALARM KEYPAD INFRINGEMENTS WILL BE PROSECUTED _i T 2021 ALL RIGHTS RESERVED/ \ THERMOSTAT o GFI / / \ \ // \ ® VENT 4 Q �I�–� ––––––––––– SD SMOKE DETECTOR n SPOTLIGHT s s CO SD SD z EPH ELEC. PANEL NEATER Robert I Brown • � SD EXISTING ELECTRICAL TO REMAIN � � PHONE/COMM. � I Architect, P.C. $ DOWN ––––––––– / i — �� — — LIGHT TRACK w 20 Bax Ave. Greenport NY PC PULL CHAIN o into@ri<brownarchitect.com PL PORTRAIT LIGHT 5'G'TO CLOCK OUTLET 631-477-9752 \ / Z DIRECT LIGHTING I \ / IT IS A VIOLATION OF TI IE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A ,\ N/TO BELOW CO CARBON MONOXIDE DETECTOR LICENSED ARCHITECT,TO ALTER ANY ITEM ON 1 OPE // \ THIS DRAWING IN ANYWAY. ANY AUTHORIZED / \ O FIRE ALARM ALTERATION MUST BE NOTED,SEALED,AND / \ STROBE DESCRIBED IN ACCORDANCE WITH THE LA / \ L31 B13 SECOND f'LOOR ELECTRICAL PLAN CLIENT,OWNER FI I ST FLOOD ELECTRI CAL PLAN SCALE: 1/4' = 1'-0' SCALE: 1/4" = 1'-0" EXISTING-AS BUILT KELLEHER EXISTING-AS BUILT I TERRENCE AND MARGARET 1075 CLIPPER DRIVE SOUTHOLD, NEW YORK 11971 PROJECT TITLE ADDITION DRAWING TITLE ELECTRICAL PLAN SCALE 23 SEPTEMBER 2o21 1/4"=i-o" DRAWING NO. r