HomeMy WebLinkAbout47854-Z �o�OS�FFQ Gy Town of Southold 3/4/2023 a P.O.Box 1179 y 53095 Main Rd ��� o� Southold,New York 11971 y OlU�y CERTIFICATE OF OCCUPANCY No: 43 891 Date: 3/4/2023 THIS CERTIFIES that the building EXHAUST HOOD AND/OR FIRE SUPRESSION SYSTEM Location of Property: 5025 Route 25, Greenport SCTM#: 473889 Sec/Block/Lot: 35.-2-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/25/2022 pursuant to which Building Permit No. 47854 dated 5/25/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations to existing kitchen fire suppression system as applied for. (Islands End Golf Course) The certificate is issued to King,William of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED ' LX1 `Authorized Signature FocK TOWN OF SOUTHOLD BUILDING DEPARTMENT H TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47854 Date: 5/25/2022 Permission is hereby granted to: King, William 33 First St Webster, MA 01570 To: KITCHEN FIRE SUPPRESSION SYSTEM ALTERATION At premises located at: 5025 Route 25 SCTM # 473889 Sec/Block/Lot# 35.-2-11 Pursuant to application dated 5/25/2022 and approved by the Building Inspector. To expire on 11/24/2023. Fees: FIRE SUPPRESSION SYSTEM $300.00 Total: $300.00 B ding Inspector TOWN OF SOUTHOLD- FIRE INSPECTORS OFFICE - TOWN HALL—MAIN ROAD-PO BOX 1179-SOUTHOLD,NEW YORK 11971 631-765-1802 ext. 5028 C ry ANNUAL CERTIFICATION OF INSPECTION AND TESTING Nov FIRE ALARM SYSTEM CAUTION: NOTIFY ALL OCCUPANTS AND ANY AGENCIES WHO MIGHT RESPOND BEFORE TESTING SYSTEM. FAILURE TO DO SO MAY RESULT IN LEGAL ACTION AGAINST THE INSPECTOR. PLEASE PRINT ALL INFORMATION NAME OF PREMISES: Island's End Golf Course ADDRESS OF PREMISES: Route 25 Greenport, NY 11944 62S_ �S FIRE DISTRICT: Greenport NAME OF OWNER OR AGENT PRESENT: Gene TYPE OF SYSTEM Automatic DOES SYSTEM REPORT TO CENTRAL STATION? Yes (MANUAL,AUTOMATIC,VOICE EVACUATION,ETC.) LIST ALL DEFICIENCIES NOTED: None WERE ALL DEFICIENCIES NOTED ABOVE CORRECTED? Yes IF NOT,WHY: NAME OF INSPECTING FIRM: LIGHTHOUSE SECURITY INC. ADDRESS OF INSPECTING FIRM: 1149 OLD COUNTRY RD STE D-5 RIVERHEAD NY 11901 NYS ALARM LICENSE NUMBER: 12000022174 EXPIRATION DATE: 11-23-24 PHONE NUMBER OF INSPECTING FIRM: 631-727-2728 DATE OF INSPECTION: 11/10/22 Certification: I, an employee of the Inspecting Firm listed above, do hereby certify that the Alarm System described above was Inspected in accordance with the applicable portions of NFPA 72 (1999 version), particularly Chapter 7 as well as Table 10.4.3&Section 10.6.2 of NFPA 72. This certification does not imply that items requiring daily, weekly, monthly, or quarterly inspection or testing were performed at the specified intervals, but does imply all such items were inspected or tested and appear to function as noted in this certification at the time of inspection. I certify that this inspection has been properly conducted and all of the above statements are true and correct to the best of my knowledge. QM-1 Sa-41LC- - 1 l0 2 0z AME OF INSPECTOR SI NATURE OF INSPECTOR DATE File form with original signature to the Fire Inspectors Office at the above address. Do not FAX. ANY FALSE STATEMENT MADE HEREIN IS PUNISHABLE AS A MISDEMEANOR Office Use Only: Date Received 1-7 ------ Irtsf s 0 5 b A reew�iad c� TOWN OF SOUTHOLD,BUILDING DEPT. C IOU ou 631-765-1802 INSPECTION FOUNDATION 1ST ROUGH PL13G. FOUNDATION 2ND I SULATIOW'CA KING FRAMING /STRAPPING INAL q�oy' FIREPLACE & CHIMNEY FF11RE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL) CODE VIOLATION PRE C/O RENTAL MARKS: 7L C" DATE - INSPECTOR V155-K� SOF SOUIH ��O �� I C/ �✓� - ��en ��-- - - _ # } TOWN OF SOUTHOLD BUILD G DEPT. o • `ycourrn, 631-765-1802 1/ INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ .] INSULATION/CAULKING [ ] FRAMING/STRAPPING 'FINAL �f [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR '=o�S�fFotK�oGy< TOWN OF SOUTHOLD—FIRE MARSHAL Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o ao� Telephone (631) 765-1802 Fax(631)765-9502 https://www.southoldtowmy_gov FIRE PROTECTION SYSTEM PERMIT Date Received APPLICATION For Office Use Only C �J'�1 n E PERMIT NO. YAF5V_Building Inspector: Applications and forms must be,filled out in'their entirety.Incomplete. RMAM 5 202 2, JD applications:will not be accepted.WORK IS NOT TO BY STARTED prior., BUILDING DEPT. to the approval of,plans.and issuance of-a permit:` TOWN OF SOUTHOLD Hasa building permit been obtained for this project? ❑Yes ❑No If yes,building permit# Date: —��.2�2 PROJECT INORMATION: Project Address: SCTM# 1000- ,35�- -- r_ o_�t.. a. - - ------ .. - - - City: Zip: cam- ► '._. _...__.z- _ ___- _ 11 R. .'CONTACT.PERSON`INFORMATION: " Name: Mailing Address: ... /17W, Phone#: ` Email: Preferred contact method(select one): ❑Phone ❑Email CONTRACTOR Name: LCSQUARED Contractor License#: Mailing Address: 335 HIGH STREET - - -.. - . - -..-. - _. _._.__..._._. ...... - Phone#: mail: X031- _ E_-..,.._ . ca�_Iwu-1��e (Q .AA - . SCOPE OF WORK: :. , Occupancy Description: ❑Assembly usiness ❑Education ❑Factory/Industrial ❑Institutional ❑Mercantile ❑Residential ❑Storage Description of Work: A .e ❑ New System xisting Sy tem Nfodification Sprinkler/Sthndpipe'/Water Supply Fire Alarm/:CO Detection.Systems. Other Fire Protection Systems. (Check all'that apply) "(Check all that apply)" (Check all that apply) , ❑NFPA 13,13D or 13R System ❑Manual ❑Automatic ❑_, Smoke Control ❑Standpipe ❑Fire Pump ❑ VProtected Premises(local) et or Dry Chemical/Clean ❑Supervising station Agent Number of sprinkler heads: ❑Central Station ❑Kitchen hood/exhaust ❑ Other Floor Area(sq.ft.): _.-.._...... .................... . ..... 1 ❑ Check Box After Reading: I,the undersigned,;understand that the issuance of a permit for the type which is herein applied for is based on the agreement to conform to'all regulations and requirements.I further understand that non-compliance of said requirements,by myself or any officer or employee of.the firm-or individual listed as.the applicant on this form,shall because for revocation of said permit.,Upon revocation of said permit the applicant or.any.employee of the applicant shall be prohibited to conduct such work for which this permit was issued.The reissuance of a permit shall be. based upon review of the circumstances leading to the revocation.Any false statement(s)made herein are punishable as a,Class A misdemeanor pursuant to Section 210.45 of the Penal Law Application Submitted By(print name): C 1reirl ❑Authorized Agent e Company(if applicable): Applicant Signature: Date: - - .. -1 _ z.... FIRE PROTECTION SYSTEM PERMIT APPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). • FIRE ALARM/CARBON MONOXIDE DETECTION SYSTEM SUBMITTAL GUIDELINES • FIRE SPRINKLER SYSTEM SUBMITTAL GUIDELINES • FIXED FIRE SUPPRESSION,HOOD&EXHAUST SYSTEMS SUBMITTAL GUIDELINES FEES A$250 permit fee is required for a non-residential permit.A$50 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testing/inspection shall be made by contacting the Town of Southold Building Department(631)765-1802. FOR OFFICE USE ONLY Amount Paid:_.= - Check No.: FM: Permit>Nti.: Date: Exp:Date::. 2 6e17%wte of 6offlpkidli This is to certify that g►lenn calder an employee of ALL OUT FIRE EQUIPMENT CO { an Authorized Kidde Fire Systems Distributor has successfully completed a certification training session covering design, installation, operation and maintenance and has demonstrated a practical knowledge of the following product: WHDRTM Wet Chemical Systems jO Kidde Issue Date: 12/2/2020 Fire Systems Expiration Date: 12/2/2023 Michael Kraus Training Manager This certificate is not transferrable.Certificate is only valid as long as the above named company employs the training participant.Acceptance of this certificate implies that the parties agree to abide by the terms of the distributor agreement or absent an agreement Kidde Fire Systems Terms and Conditions of Sale.Any violation or alteration of this certificate will result in the immediate voiding of this certificate and possible revocation of access to the Kidde Fire Systems product line pertaining to this certificate. Portable High Dry/Wet Clean Agent Reg Expiration Fire .Pressure Chem Extinguishing # Date Applicant Facility Address Telephone# Extinguisher Hydrostatic Extinguishing Systems 175- 11/30/2021 J.Fire Protection Inc.dba Star Fire Protection Co. 224-50 Braddock Ave ❑ ❑ ❑ ❑ expired 1-718-217-1900 Star Fire Protection Co. Queens Village,NY 11428 126. 9/30/2022 Johnson Controls Fire Protection LP, 35 Arkay Drive ❑ ❑ 0 631-404-1000 Hauppauge,NY 11788 108 1/31/2023 Ken-Mar Fire Extinguisher Co.,Inc. 168 Larkfield Road ❑ ❑� ❑ El631-261-3506 East Northport,NY 11731 124 8/31/2023 LC Squared dba All-out Fire Equipment 385 High Street ❑� ❑ ❑� 631-580-0303 All Out Fire Equipment Holbrook,NY 11741 151 11/30/2022 Long Island Fire Prevention,Inc. 1465 S.Strongs Avenue ❑� ❑ ❑� ❑ 631-225-7700 Copiague,NY 11726 109 3/31/2023 Lund Fire Products Co.,Inc. 40-3321 Sth Place ❑� 718-423-1900 Bayside,NY 11631 133 1/31/2023 M&M Fire Extinguishers,Inc,dba Professional Fire 151-21 W.Industry Ct ❑ ❑ ❑ Service,Inc. 631-243-6304 dba Professional Fire Service,Inc. Deer Park,NY 11729 176- 9/30/2022 M&M Fire Extinguishers Sales&Service,Inc. 151-21 West Industry Court : ❑ ❑ 631-464-5609 Deer Park,NY 11729 - 161 12/31/2022 Miron Group,Inc.dba Pinnacle Hood&Fire Protection 42B Kean Street ❑� ❑ ❑� ❑ Systems 631-991-8080 dba Pinnacle Hood&Fire Protection Systems West Babylon,NY 11704 144 8/31/2022 National Fire&Safety Solutions,Inc. 211 Knickerbocker Avenue ❑ ❑ 0 631-234-5656 Bohemia,NY 11716- 177 8/31/2022 New Generation Fire Corp.DBA All Island Fire Protection 100A Knickerbocker Ave ❑ ❑ 631-286-4000 All Island Fire Protection Bohemia,NY 11716 145 1/31/2023 North Shore Fire Equipment 12 Bay Avenue ❑ ❑ ❑ 516-922-1156 Oyster Bay,NY 11771 181 1/31/2023 Peconic Fire Equipment,Inc. 1109 Noyac Road 0 ❑ ❑ ❑ 631-283-3767 Peconic Fire Equipment Distributers Southampton,NY 11968 Friday,March 18,2022 Page 3 of 4 Component Description A _ = B TOP OF CENTER OF CYLINDER VALVE DISCHARGE PORT NOMINAL CYLINDER DIAMETER Figure 2-1. Dimensions of Cylinder and Valve Assembly, PJM 87-12XXXX-001 Refer to Figure-5-26 for Cylinder Valve details. Table 2.1. Cylinder and Valve Assembly Specifications Cylinder and Valve Maximum Dimensions Assembly Number Model Flow Number A 8 C 87-120001-001 WHDR-125 4 15-1/4 in. 13-3/4 in. 8 in. (387 mm) (349 inm) (203 mm) 87-120002-001 WHDR-260 8 21 in. 19-5/8 in. 9 in. (534 mm) (498 mm) (230 mm) 8,7-120003-001 WHDR-400S 12 19 in. 17-1/2 in. 12-1/4 in. (483 mm) (444 mm) (311 mm) 87-120006-001 WHDR-400M 12 24-3/8 in. 23 in. 10 in. (619 mm) (584 mm) (254 mm) 87-120005-001 WHDR-600 18 35-1/8 in. 33-3/4 in. 10 in. (892 mm) (857 mm) (254 mm) 87-125001-001 WHDR-5EU4 15-114 in, 13-7/8 in. 8 in. (381 mm) (352 mm) (203 mm) 87-125002-001 WHDR-IDEU 8 21 in. 19-5/8 in. 9 in. (533 mm) (498 mm) (229 mm) 87-125003-001 WHDR-SI5EU 12 18-7/8 in. 17-1/2 in. 12 in. (479 mm) (445 mm) (305 mm) 87=125006-001 WHDR-M15EU 12 24-3/8 in. 23 in. 10 in. (519 mm) (584 mm) (254 mm) 87-125005-001 WHDR 23EU 18 35 in. 33-1/2 in. 10 in. (889 mm) (851 mm) (Z54 mm) P/N 87-122000-001 2-3 April 2009 Component Description 2-1.1.1 CYLINDER BRACKETS CYLINDER STRAP CYLINDERSTRAP C FRONT VIEW SIDE VIEW Figure 2-2. Mounting Brackets Table 2-2. Mounting Bracket Dimensions Dimensions Part No. Model A B C 60-9197430-000 WHDR-125 3 in. 9-3/8 in. 1-3/8 in. WHDR-5EU (16 mm) (238 mm) (35 mm) 60-9197263-060 WHDR-260 4-1/2 In. 12 in: 2-1/2 in. WHDR-10EU (114 mm) (305 mm) (64 mm) 60-9197414-000 WHDR-400M 4-1/2 In. 20-1/2 in. 2-1/2 in. WHIJR-M15EU (114 mm) (621 rom) (64 mm) 60-9197415-0.00 WH.D.R-400S 4-112 in. 11-112 in. 2 in. WHDR-515EU (114 mm) (290 mm) (51 mrin April 2009 2-4 P/N 87-122000-001 Component Description CYLINDER STRAP C A Figure 2-3. Shelf Bracket, P/N 87-100013-001 Table 2-3. Mounting Bracket Dimensions Dimensions Part No. Model A i3 C 7 87-100013-001 WHDR-600, WHDR-400M, 11 in. 10-1/8 in. 21-1/8 In. WHDR-M15EU, WHDR-23EU (279 mm) (258 mm) (537 mm) I 2-1.1.1.1 Floor Mount Bracket Kit, P/N 87-100010-001 A.Floor Mount Bracket Kit is used for mounting the WHDR-6001WHDR-400M/ WH,DR-M15EU/WHDR-23EU cylinder to the floor. The Floor Mount Bracket Kit requires Wall Mounting Bracket P/N 87-100013-001, 116 in'DIAMETER BOLTSTOATTACH TOWALLMOUNTING 3M In.DIAMETER BRACKET BOLTS TO ATTACH TO WALL MOUNTING BRACKET 1-4A Figure 2-4. Floor Mount Bracket Kit, P/N 87-100010-001 Table 2-4. Floor Mounting Kit Specifications Dimension A Dimension 0 Dimension C 3 in. (76 mm) 9-5/8 in. (245 mm) 6-9/16 in. (168 mm) P/N 87-122000-001 2-5 April 2009 Component Description 2-1.1.2 DISCHARGE ADAPTER KIT, P/N 83-844908-000 The Discharge Adapter provides a means to connect agent distribution pipe to all Kidde Wet Chemical Cylinder and Valve Assemblies. The Discharge Adapter Kit consists of a 3/4-inch NPT external thread and 1/2-inch NPT internal thread adapter and a steel flange plate (Figure 2-5j, Note: The nuts and bolts-used to secure the Anti-Recoil Plate to the discharge valve should be retained and used for mounting the Discharge Adapter to the valve outlet. The Discharge.Adapter can also be used as a recharge adapter to pressurize the cylinder with nitrogen after filling with wet chemical. Note: This part must be ordered separately. It is not included with the Cylinder and Valve Assembly. FLANGE PLATE V2 in.NPT (INTERIOR) ADAPTER 314 in.NPT ' (EXTERIOR) =` ;? O-RING Figure 275. Discharge Adapter Kit, P/N 83-844908-000 April 2009 2-6 P/N 87-122000-001 Component Description 2-1.1.3 DISCHARGE NOZZLES There are essentially seven types of nozzles in the Kidde wet chemical system. They are: • ADP F • DM • R. • GRW • LPF • LPR Each nozzle has: • Stainless steel internal strainer and nickel-chrome plated brass body • Special foil seal over the discharge orifice to prevent grease from depositing In the orifice and plugging the nozzle o Grooved rings on the body define the nozzle type (Refer to Table 2-5) • Body is.stamped with nozzle type and Kidde/RG as shown in Figure 2-6. Figure 2-6. Example of Nozzle Stamped with Nozzle Type and Kidde/RG Note: Older nozzles are stamped "Kidde". Newer nozzles are stamped 'Kidde/RG". It Is permissible to use old and/or new nozzles included in this manual in a Kidde system. PIN 87-122000-001 2-7 April 2009 Component Description Table 2-5. WHDR Nozzles Nozzle Type Part Number' Flow Number Grooves ADP Nozzle 87-120011-001 1 1 - _ r F Nozzle 87-120012-001 2 2 PT- GRW Nozzle 87-120013-001 1 3 r ` R.Nozzle 87-120014-001 1 4 = DM Nozzle 87-120015-001 3 0 <_ LPF Nozzle 87-120022-001 2 1 &4 �r LPR Nozzle 87-120024-001 1 Disc&Core April 2009 2-8 P/N 87-122000-001 Component Description 2-1.1.3..1 ADP Nozzle, P/N 87-120011-001 ADP nozzles are used for the following hazards: • Ducts • Plenums • Flat cooking surfaces (griddle) • Split Vat Deep Fat Fryers (low proximity) • Upright Broilers (Salamander) • Closed-top Chain Broilers + Open-top Chain Broilers • Natural/Mesquite Charcoal Charbroiler • Krispy Kreme Model 270 d/h Donut Fryer INTERNAL THREAD 3/8 In.NPT 13/16 in,(21 mm) - 1 GROOVE 9/16 in. 14 mm Figure 2-7. ADP Nozzle, P/N 87-120011-001 2-1.1,3.2 F Nozzle, P/N 87-120012-001 F nozzles are used for the following hazards: • Fryers • Tilt Skillets/Braising Pans • Purnice Rock (Lava, Ceramic) • Charbroilers INTERNAL THREAD / 318 in.NPT (48 �J 13/16 in,(21 mm) - 2 GROOVES 9116 in.(14 mm) Figure 2-8. F Nozzle, P/N 87-120012-001 P/N 87-122000-001 2-9 April 2009 Component Description 2-1.1.3.7 . LPR Nozzle, P/N 87-120024-001 LPR nozzles are used for the following hazard: • Ranges INTERNAL THREAD 318 in.NPT 13116 in.(21 mm r:•=_f NO GROOVES 13116 in.(21 mm) Figure 2-13, LPR Nozzle, P/N 87-120024-001 2-1.1.3.8 Swivel Adapter, P/N 87-120021-001 The swivel adapter may be used conjunction with any nozzle. (sZ mm) 3/8 in.(10 mm)NPT 318 in.(10 mm)NPT (INTERNAL THREAD) 1 in. 25 mm HEX. ( ) � 718 in.(22 mm)HEX Figure 2-14, Swivel Adapter, P/N 87-120021-001 April 2009 2-12 P/N 87-122000-001 Component Description 2-2 CONTROLS 2-2.1 XV"" Control System, P/N 87-120099-001 The XV Control System,P/N 87-120099-001,is used for actuating the Kidde Cylinder and Valve Assembly. The." Control System can be attached to the System Valve Actuator, P/N 87- 120042-001 for direct cylinder mounting, or to a wall for remote mounting, knockouts are provided to accommodate either type of mounting. The controller can be operated with: • Automatic mechanical detection (fusible-links and thermo-bulb links), • Automatic electrical operation, and • Remote and local manual operation, � - - - t-- . g.; - ;t -= t` 9-7/16 in. (240 mm) 3-3/4 in. 8-3/16 in. (95 MM) (208 mm) Figure 2-15. XV Control System, P/N.87-120099-001 P/N 87-122000-001 2-13 April 2009 Component Description 2-2.1.3 SYSTEM VALVE ACTUATOR (SVA), PIN 87-120042-001 A System Valve Actuator(SVA)is mounted to every wet chemical cylinder valve assembly(see Figure 2-18). The SVA has ports for low profile tubing runs, and Is also equipped with a spring loaded plunger that locks the piston in the discharged position, ensuring complete discharge of the cylinder(s) contents. SM-18 UNC THROUGH HOLE(TYP). (NOT SHOWN) NPT PORT 118 in.NPT PLUG (IF APPLICABLE) SVA PISTON IN SPRING LOADED SET POSITION PISTON IN ACTUATED PLUNGER POSITION(TOWARDS CYLINDER VALVE) Figure 2-18. System Valve Actuator(SVA), PIN 87-120.042-001 P/N 87-122000-001 2-15 April 2009 Component Description 2-2.1.6 MICROSWITCH KIT, P/Ns 87-120039-001, 87-120039-501 (FOR XV) The Microswitch Kit is a single pole, double-throw switch (see Figure 2-21 and Table 2-7). Included in the kit is the:microswitch, pigtail assembly and four mounting screws (two short and two long). Note: Microswitch Kit P/N 87-12003.9-501 includes a pigtail assembly with white stripes. The wire leads are 24-inches(610 mm) in length. Four Microswitch Kits can be mounted in the XV Control System. There are two mounting locations to accommodate the four Microswitch kits (two stacked at each mounting location), with EMT ports for each mounting location. This allows.for the use of two electrical junction boxes for separation of signal lines and AC lines. These are used when it is necessary to open or close electrical circuits. The following are examples, but not limited to: • Electric'appilance shutdown • Make up air shutdown • Electric gas valve shutdown • Shuntbreaker/relay Note: Not for alarm initiation. Electrical appliances usually have a higher amp rating than the switches. In this case, such appliances shall not be wired directly to the microswitch. A magnetic contactor or relay must be used. For wiring the microswitch for XV, refer to Figure 4-30. ~- -_ /rELECTRICAL CONNECTOR Xz MICROSWITCH Figure 2-21. Microswitch Kit, P/Ns 87-120039-001, 87-120039-501 Table 2-7. Microswitch Electrical Ratings 125/250 Vac 20.5 Amps 250 Vac 1-1/2 HP 125 Vac 1/2 HP April 2009 2-18 P/N 87-122000-001 Component Description 2-2.3.2 UNIVERSAL-LINK HOUSING KIT, P/N 87-120064-001 The Universal-Link Housing Kit, shown in Figure 2-29, consists of the following: Table 2-12. Universal Link Housing Kit, P/N 87-120064-001 Item Quantity 11-1/2 in. (292 mm) Detector Housing 1 Crimp Sleeves 2 "S"Hooks 2 The items above are used to attach the Fusible-Link or Thermo-Bulb Links to the 1/16-inch cable leading to the XV Control System or KRS-50 Control Box.The Universal-Link Housing can be configured as an Ertd-of-Line or In-Line bracket. Ill in.CABLE TO CONTROL SYSTEM (NOT SUPPLIED) "S"HOOKS CRIMP SLEEVE f THERMO-BULB LINK +��1Ai2�n t LOCKNUT OR FUSIBLE-LINK (NOT SUPPLIED) (NOT SUPPLIED) 1 THERMO-BULB LINK OR FUSIBLE-LINK CRIMP (NOT SUPPLIED) �HEMT EXAMPLE OF IN-LINE EXAMPLE OF H �' .�Sn CONNECTOR UNIVERSAL HOUSING KIT UNIVERSAL HOUSING KIT IT HOOK SLEEVE 1112 In. (NOT SUPPLIED) Figure 2-29. Example of End-of-tine and In-line Universal Link Housing Kit, P/N 87-120064-001 PIN 87-1-22000-001 2-25 April 2009 Component Description 2-2.3.4 FUSIBLE-LINKS(MODEL KML), P/NS WK-282661-000, WK-282662-000;WK-282664-000 AND WK-282666-000 Fusible-Links are available in various temperature ratings with a minimum/maximum load rating of 10 lb./40 Ib. (5 kg/18 kg) (see Table 2-14). _ o Figure 2-31. Fusible-Link, P/N 28266X Table 2-14. Fusible-Link Temperature Ratings Fusible-Link Rating Maximum Exposure Color Part Number Temperature (Old Part Number) 165°F(74°C) 100°F(38°C) Yellow WK-282661-000 (282661) 212°F (1000C) 150°F (65°C) White WK-282662-000 (282662) 360°F(182°C) 300°F(149°C) Unpainted WK-282664-000 (282664) 500°F(260°C) 440°F (226°C) TOrange WK-282666-000 (282666) The rating temperature, which is stamped on the Fusible-Link, is the temperature at which the link will separate when new. However, continual exposure to cycling ambient temperatures may cause a degradation of the link over time. P/N 87-122000-001 2-27 April 2009 3/411 PIPE F- - - - - - - - -, r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - XV OSEPH ' CONTROL ' GADRIEL AIA HEAD 14" x 14" DUCT ' 12" x 12" DJCT ` : ARCHITECTS,PC ONWALL - - IN THE BACK I 6450 Vale ro ns Memor of Hwy. 5,11, ".00 E. Holorool hV IN THE BACK OF THE OF THE HOOD I ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE THE HOOD I ORIGINAL AND UNPU_JSHED WORK OF THE ARCH AND THE SAME MAY NOT BE DUPLICATED, USED, OR DISCLOSED WIiHdUT THE WRITTEN I CONSENT OF THE IACFir ECT. ' APPROVALS _ _ _ _ _ _ _ _ DP -D��- - - - - - - � -�- - P - LI 91-011 EXISTING HOOD I I 3'-9" EXL�TLN� HOOD WHDR- WHDP- 1 �� ' 125 400 I I , ADP ADP GRW F 0 0 0 SPLATTER SHIELD WALL' LPIli R LP I 112" 000@ 000 0 0 ASCO GAS �� VALVE I N CEILING FLOW POINTS: ALL OUT EIRE 12/ 12 FLOW POINTS: 2/4 385 HIGH STREET, H01-BROOK, NY, 1 1 741 PULL STATION 3G" 3G_'I 2411 I G" �I G 11 (G3 1 ) 580-0303 G BURNER RANGE FLAT GAS RADIANT FRYER FRYER W/ SALAMANDER GRIDDLE GRILL 5Y5lEM DIAGRAM SCALE: 1/2"= 1 '-0" SYSTEM DIAGRAM 15LAND5 END GOLF 502.5 ROL ITE 25 PIPING D15CHARGF LINE VOLUME5: APPLIANCE LINE 1 I GREEN PORT, NY, 1 1 944 PIPING DISCHARGE LINE VOLUMES: - — I - III _ 2.29 IN3 PER LINEARFOOT;y 2.29 IN3 X 9LFT= 20.6 I IN3 FRYERS TO HAVE I1iGH LIMIT CONTROL TO SHUT OF FUEL AT 425°. /4 – 1 .25 IN3 PER LINEAR FOOT DETECTOK S SHALL. BE LOCATED OVER eveRY PIECE of EQUIPMENT. %" = 2,29 IN3 PER LINEAR FOOT /211 = 3.65 1N3 PER LINEAR FOOT- 3.65 EN3 X 28LFT = I 0?_.21N3 - TI IE SYSTEM IN5TALLED AS PFR MANUFACTURERS SPECS AND THE AriJ. _ %2' = 3.65 IN3 PER LINEAR FOOT TI1E SYSTEM HA5 BEEN INSTALLED AS PER uLsoo. TOTAL FIFE VOLUME: f 22.8 I IN3 – THE FOLLOWING OPTIONS TO OPERATE UPON SY5TENA D15CHARGE: i 3/_�" = G.40 IN3 PER LINEAR FOOT TOTAL ALLOWABLE PIPE VOLUME: 400 IN3 • SUPPLY AIR DAMPER CLOSES 1 " = 1 0.3 7 IN3 PEP, LINEAR 1`001- • EXHAUST FAN REMAINS ON • ALL SYSTEMS TO ACTIVATE SIMULTANEOUSLY IN SAME PIPING DISCHARGE I_-INE VOLUMES: DUCT LINE t1AZARD AREA. • FiRE ALARM 5HALL ACTIVATE. I TOTAL ALLOWABLE PIPE VOLUMES • GA5 FUEL SHUTS OFF IN KITCHEN. 3/8" = 2.29 IN3 PER LINEAR FOOT—> 2.29 IN3 X 17LFT= 38.93 IN3 • ELECTRIC FUEL_SHUT OFF UNDEK HOOD. �NI-iDR 12.5 = 72 IN %2" — 3.65 IN3 PER LINEAR FOOT--->3.G5 IN3 X I GIFT = 58.41N3 MANUAL PULL IS LOCATED 10-?_Of'T FP,CM HOOD AND 41'T FROM WHDR 260 = 139 IN3 FLooK. 3 TOTAL PIPE VOLUME: 97.33 IN3 - ALL FUEL_SOURCES ARE GAS UNLESS oTHeRwISE NOTED. WHDR 400 = 400 IN WHDR GOO = 400 IN3 TOTAL ALLOWABLE PIPE VOLUME: 400 IN3 JDJ liL j'- it flu - I'Ay 25 2022 LD , BUILDING DEPT. TOWN OF SOUTHOL D NOZZLE SURFACE NOZZLES EQUIPMENT QTY AREA PART# HEIGHTS LOCATIONS 155ue Description Date DUCT 1 12" X 12" ADP 10011 CENTERLINE SEAL 51GN,ATUKE DUCT 2 14" X 141' ADP 100" CENTERLINE -� SYSTEM: NEWS EX15 ING �� s KI DDE GAS VALVE: NEW_X_.-- EXISTING PLENUM 2 4X 12 ADP 120" CENTERLINE ?�.���Gu ��``° � II X I .25 G 2l,G G 4G S X 4G M _—GG G 3LJ!�,NSC R RANGE 1 3G X 24II LPR 16II-20II CENTERLINE PIPING MATERIAL: BLACK SCh 40 SALAMANDER I 3G" X 28" ADP ABOVE FRONT GRATE AIMED AT OPPOSITE BACK CORNER SUPPLY PIPE SIZE: %" BRANCH PIPE SIZE : 3/b" 2 (2)FRYER I EACH I G" X 18" F 27"-45" CENTERLINE GAS VALVE TYPE MECH SIZE: 112 " BRAND: ASCO GAS RADIANT GRILL 1 24" X 24" GRW 13"-4811 CENTERLINE DATE: 05-04-22 DETECTOR TEMPERATURE RATING= 3GOD FLAT GRIDDLE I 3G" X 24" ADP 13"-48 PERIMETEP� JOB No: AIMED AT CENTER DRAWING BY: TP HOOD SIZE : 9'--0" � 3'-9" DUCT SIZE :12" X 12" CHK BY: JG 14" X 14" DWG No: I OF I 3/4" PIPE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I XV JOSEPH ' CONTROL yLL 14" x 14" DUCT GABRIEL,AIA HEAD 1 2" x 1 2" DUCT ARCHITECTS,PC ON WALL - - –I IN THE BACK I 4250 Velzrens Meme Hwy. Suite. 280F, H,Ib,o°t NY IN THE BACK OF THE OF THE HOOD ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHRECT AND THE SAME I HOOD I MC Y NOONSENT TBE UUPTNE CH�. USED, OR DISCLOSED WRHdUT THE WRrfTEN I APPROVALS D7 3'-9" EXLSTLN� HOOD 9'-0" EXISTING HOOD I I L---J rVVHDP- WHDR- / ' 125 400 I i I i I ADP ADP GRW F 0 0 0 SPLATTER 5NELD WALL LPR LPR 1 1 112" I _ 0 0 0@ 0 0 0 0 ® ASCO GAS VALVE IN CEILING DD � I FLOW POINTS_ : 12/ 12_ ALL OUT FIRE 385 HIGH STREET, FLOW POINTS: 2/4 HOLBROOK, NY, 1 1 741 LL' PULL STATION 3G" 3G° 24" 16" 16" � � � � � (b-31 ) 580-0303 G BURNER RANGE FLAT GAS RADIANT FRYER FRYER W/ SALAMANDER GRIDDLE GRILL SYSTEM DIAGRAM SCALE: 1i2"= 11-0" SYSTEM DIAGRAM ISIAND5 END GOLF 5025 ROUTE 25 PIPING DISCHARGE LINE VOLUMIC': PIPING DISCHARGE_ LINE VOLUMES: APPLIANCE LINE GREEN PORT, NY, I 1944 NO TLS: — FRYtRs To HAVE HIGH !_!MIT CONTROL TO Shur of FUEL AT 425°. X4" = 1 .25 IN3 PER LINEAR FOOT 2.29 IN3 PER LINEAR FOG��� 2.29 IN3 X 9LFT= 20.6 I IN3 — DETECTORS SHALL BE LOCATED OVER EVERY PIECE OF EQUIPMENT. X8" = 2.29 IN3 PER LINEAR FOOT /2° = 3.65 IN3 PER LINEAR FOOT- 3.65 IN3 X 28LFT = 102.21^J3 — THE SYSTEM INSTALI_LD AS FFK MAN;UFACTUR.ERS SPECS AND THE AHJ. X2" = 3 E5 IN3 PER LINEAR FOOT — THE SYSTEM HAS SEEN INSTALLED As PELF,UL300. TOTAL PIPE VOLUME: 122.81 IN3 - THE FOLLOWING OPTIONS TO OPERATE UPON SYSTEM DISCHARGE: 1 3/4" = 6.40 IN3 PER LINEAR FOOT TOTAL ALLOWABLE PIPE VOLUME: 400 IN3 • 5UPPLY AR DAMPER CLOSES 1 " = 10.37 IN3 PER LINEAR FOOT • EXHAUST FAN KFMAINS ON • ALL 5Y5TEM5 TO ACTIVATE 5IMULTANFOUS'Y IN SAME PIPING DISCHARGE LINE VOLUMES: DUCT LINE HAZARD AEA. • FIRE ALAI;M SHALL ACTIVATE. TOTAL ALLOWABLE PIPE VOLUME5 • GAS FUEL 5111 ITS OFF IN KITCHEN. -- 3/g" = 2.29 IN3 PER LINEAR FOOTS 2.29 IN3 X 17LFT= 38.93 IN3 • ELECTRIC FUEL SHUT OFF UNDER HOOD. WNDR 125 = 72 IN3 X211 = 3.65 IN3 PER LINEAR FOOT— 3.65 IN3 X 161_FT = 58.41N3 MANUAL PULL 15 LOCATED 10-20FT FROM HOOD AND 4r"T FROM FLOOR. WHDR 260 – 135 IN3 WHDK 400 = 400 IN3 TOTAL PIPE VOLUME: 97.33 IN3 — ALL FUEL SOURCES ARE GAS uNLess oTHEKwISE NOTED. U✓HDR 600 = 400 IN3 'TOTAL ALLOWABLE PIPE VOLUME: 400 IN3 2r- e. a /fl SUH_DINIG DEPT. TOlydP!Or SOUTHO'-D NOZZLE. SURFAC= NOZZLES EQUIPMENT CITY AREA PART# HEIGHTS LOCATIONS Issue Description Date DUCT 1 12" X 12" ADP 1001, CENTERLINE SEAL 51GNATUPE SYSTEM: NEW—? EXISTING DUCT 2 1 4" X 1411 ADP 100" CENTERLINE KIDDE �, ,a�.�,J, GAS VALVE: NEWS EXISTING PLENUM 2 4X 12 ADP 120" CENT[KLINE X I .25 G 2.6 G 4G S X 4G M GG 6 BUR\NER RANGE I 3G" X 24" LPR 16"-2011 CENTERLINE ABOVE FRONT GRATE AIMED AT ! – PIPING MATERIAL: BL ACK SCH 40 SALAMANDER I 3G" X 28" ADP � . OPPOSITE BACK CORNER BRANCH PIPE SIZE :X211 3/(5" II II 11 i J1 113 SUPPLY PIPE SIZE: (2)FRYER 1 EACH 1 6 X 1 8 F 27 45 CENTERLINE � ` `"""�r�" GAS VALVE TYPE MECH SIZE: I X2 " BRAND: ASCO GAS RADIANT GRILL 1 24" X. 24" GRW 1311-4811 CENTERLINE DATE: 05-04-22 DETECTOR TEMPERATURE RATING= 360° FLAT GRIDDLE I 3611 X 24" ADP 1311-4811 PERIMETER JOD No: AIMED AT CENTER DRAWING BY: TP HOOD SIZE : 9'-0" * 3'-911 DUCT SIZE :1 2" X 12' CHK BY: JG 14" X 14" DWG No: 1 0F I