Loading...
HomeMy WebLinkAbout26831-z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-27560 Date: 02/16/01 THIS CERTIFIES that the building ADDITION Location of Property: 1420 LAURELWOOD DR LAUREL (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 127 Block 5 Lot 6 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated OCTOBER 6, 2000 pursuant to which Building Permit No. 26831-Z dated OCTOBER 6, 2000 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITION & INSTALLATION OF WOOD STOVE IN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to ROBERT A & BARBARA LOCKMAN (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. N-411237 02/14/97 PLUMBERS CERTIFICATION DATED N/A ch, /" Authorized Sig ture Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 26831 Z Date OCTOBER 6, 2000 Permission is hereby granted to: ROBERT A & WF LOCKMAN PO BOX 2 LAUREL,NY 11948 for CONSTRUCTION OF AN ADDITION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR k C r1C(Nj oq :��10�� at premises located at 1420 LAURELWOOD DR LAUREL County Tax Map No. 473889 Section 127 Block 0005 Lot No. 006 pursuant to application dated OCTOBER 6, 2000 and approved by the Building Inspector. Fee $ 75 . 00 Authorized Sign ure ORIGINAL Rev. 2/19/98 Form No. 6 �+ IL 4.t..d TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR.CERTIFICATE OF OCCUPANCY A. This application must be filled in by typewriter OR ink and submitted to the building inspector with the following: for new building or new use: 1. Final survey of .property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form) . 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and 11pre-existing" land uses: 1 . 4Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building ,$25.00. Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - .25'up 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residentialp$15.0/0.j, Commercial $15.00 � � Date . . J.`:�c . � . L.�. �Q.�. . . . . . . . . . . . . . . . . . . New Construction. . .!. . . . . . . Old Or Pre-existing Building. . . . Location of Property. . . �Lfo�E?. . . . .Lat_ r;ek W Cp©d. . . .��;l Ne, . . . . .LCL Vl!te� . . . . . . . . . . . . House No. _ Street • •� Hamlet Onwer or Owners of Property. ©!�? ; ,�rba rza ,n , , , , , , , , , , , , , , , , , , , , , , 14. County Tax Map No 1000, Section. a. 7. . . . . . . .Block. . . . . . . . . . . . . . . .Lot. . . . . . . . . . . . . . . . . . . . Lau.r-e.twood r3s`�u " Subdivision. . , . . . . . .Filed Map. . . . . . . . . . . .Lot. . . . . . . . . . . . . . . . . . . . . Permit No. . .2-(. . . . .S3 1:.Z?.Date Of Permit. . . . . . . . . . . . . . . .Applicant*!: .e . . ; Health Dept. Approval. . . . . . . . . . . . . . . . . . . . . . . . . .Underwriters Approval. . . . . . . . . . . . . . . . . . . . . . . . . Planning Board Approval. . . . . . . . . . . . . . . . . . . . . . . . Request for: Temporary Certificate. . . . . . . . . . . Final Certicate. . . .�. . OS Fee Submitted: $. . �. ��, , , , , , , , , , , , , , , . . . . . . . . . . . . . . . . . .'. . . . . . . . . C �410 CO ?5 G 6 APPLICANT fFOJq-c0 o� Town Hall,53095 Main Road ti Z Fax(631)765-1823 P.O.Box 1179 O .F Telephone(631)765-1802 Southold,New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD FEB. 12 , 2001 MR. ROBERT A. LOCKMAN P.O. BOX 2 LAUREL, N.Y. 11948 To Whom This May Concern: We are unable to complete your Certificate of Occupancy because of the following reasons : XX An application for Certificate of Occupancy is not on file . (Enclosed) r No Underwriters Certificate on file . XX The check is (not on file . ) $25 . 00 No Health Department Approval on file . No final inspection has been made . No Plumber Solder Certificate on file . (All permits involving plumbing being issued after April 1, 1984) . BUILDING PERMIT # 26831-Z Please contact our office on this matter. Thank you for cooperation. SOUTHOLD TOWN BUILDING DEPT. THE NEW YORK BOARD Or FIRE UNDERWRITERS PAGE 1 10@1.105 BUREAU OF ELECTRICITY 85 JOHN STREET, NEW YORK, NY 10038 BRUARY 14,199`7 Application No.on file 13035996/96 N 411237 THIS CERTIFIES THAT only the electrical equipment as described below and introduced by the applicant named on the above application number in the premises of ROBERT LOCKMAN, 1420 LAUREL WOOD DRIVE, LAUREL, N.Y. in the following location; ❑ Basement ER I st Fl. ❑ 2nd Fl. OUT Section Block Lot was examined on FEBRUARY 10,1997 and found to be in compliance with the National Electrical Code. FIXTURE FIXTURES RANGES COOKING DECKS OVENS DISH WASHERS EXHAUST FANS OUTLETS RKWTACLES SWITCHES INCANDESCENT FLUORESCENT OTHER AMT. K.W. AMT. K.W. AMT. K.W. AMT. K.W. AMT. H.P. 7 8 4 7 DRYERS FURNACE MOTORS FUTURE APPLIANCE FEEDERS SPECIALRRC'1T TIME CLOCKS ULL UNIT HEATERS MULTI.OUTLET DIMMERS OIL M.P. GAS M.P. AMT. NO. A.W.G. AMT. AMP. AMT. AM►S. TRANS. AMT. H.P. SYSTEMS NO.OF FEET AMT. I WATTS 3 600 SERVICE DISCONNECT NO.OF S E R V I C E AMT. AMP. TYPE It l,e'4M/ 1/'TN 9/3W 7/IW NO.OF CC.COND. A.W.G. NO.OF HI•lFG A•W G• NO.OF NEUTRALS A,W G- AMT. OF CC.CON,. OF MI-LEG OF NEUTRAL 1 7- OTHER APPARATUS: ELEC. ROOM HEATERS:2-1.5 K.W. WILDWOOD ELECTRIC LIC.#1563 4th STREET P.O.BOX 808 GRIMM MANAGER WADING RIVER, NY, 11712 11 • per :-.L...� This certificafe must not be altered in any manner; return to the office of the Board if incorrect. Inspectors may be identified by their credentials. COPY FOR BUILDING DEPARTMENT. THIS COPY OF CERTIFICATE MUST NOT BE ALTERED IN ANY MANNER. T65-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSU f10N [ ] FRAMING [ FINAL [ ] FIREPLACE & CHIMNEY r REMARK . � c✓�� ry Y c�� KJ DATE `O / INSPECTOR BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ j ROUGH PLBG. [ ] FOUNDATION 2ND [ 7NAL TION FRAMING � [ [ ] FIREPLACE 8 CHIMN Y REMARKS: 7 ,DATE INSPECT P I I;I.0 I tl:il'Ia;l 1 UN IlKlIORT DATE. COMMIsNT� � _---�aeti --•- -- --- ---- F UUNUAT(QN (2rtU) I,I Ito lIGII DRANK 6 O G Ia1.urin r rlc � I' `� L7 11I!NI1.AT I ON Cr.t( ti. y . STATE. RNIIRCY a ... _--,,,--, .,.--aim—. ,---.—�_.. -�---�----- ,•,�—_� I I NAL y 8 �rZ QCO •-*'—�--*--a--'—``--*_>-*--�,�—a�ma�,aT-_ ..�/ �•�v�-'-T-.Ta�_ �nwz, �..}.��m�r..=r=�::., — ' / T AI)I)1.'t'I UrtA I. UNMI;N'i':; ...z-v---r.aim n.... a:�r_sar_ena a-a.s-ate-r„ t I - to6ero— . AZ-r. o)- BUILDING DEPT. � INSPECTION [ FOUNDATION 18T [ ] ROUGH PLBO. [ j FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL REMARKS: 7f aF c��- s a,,o%-_ry �2 DATE �� -INSPECTOR rJAIA BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I�TION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: DATE 71,f1f&q INSPECTOR_%�2� G� X65.1802 BUILDING DEPT. INSPECTION � [ ] FOUNDATION IST [ ] ROUGH PLBG. [ j FOUNDATION 2ND [ ] INS CATION [ ] FRAMING [ FINAL [ ] FIREPLACE & CFIIMNEY REMARKS: C DATE Z -S l�8 INSPECTOR_��� M-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] 1 SOLATION [ ] FRAMING [ FINAL [ ] FIREPLACE & CHIMNEY REMARKS: DATE 311,�' 97 INSPECTOR 2�� M-1802 ,-� BUILDING DEPT. INSPECTION � [ ] FOUNDATION iST [ ] GH PLBG. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: DATE INSPECTOR �"� M-1802 UILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [✓J FINAL [ ] FIREPLACE & CHIMNEY REMARKS• l l DATE 0 INSPECTOR 1sNLRGX CODE CALCULATIONS (par Nota-LlecLric heat) Desiytt Criteria 6 , 000 Degrce'.Days O.A. 101IF I.A. 700E FOR., f- O G W0 PER: Q ule It O 11l;):A _ � DESIGN '1'111�.RMCL REMARKS SUBSYSTEM i1R1s11 "U" RAT 1NG l:xLer.i.ot: Wails (Opaque) Glazing 11 $ J 1 3 L - /3 m►- c e-) Doors 7 44 `� -- —----------- Ceila.t►y/lZoof (Opaque) �z �j 0 (� Skylights - ' % Z , 3 S I Or a pu e kloor .� s OJ Foundation Walls Slab Insulation TOTAL Hot-es: 11ui1d1.ng Bnvelope Systems to meet requirements of: 7815 . 2 11VAC 13qulpement. to meet. requirements of 7015 . 11 11VAC Systems Lo meet requirements of 7015 . 12 Duct SysLems to meet- requirements of 70:1.5. 1.3 VentilaUons Systems Lo meet requirements of '1015 . 14 lnsuaaLion of p1pirny Systems to meet requil:emettts of 7U15 . 15 Ser:vice WaL-er lleatitty Systems & LquipmenL to meet requirements of '1015 . 21. Electrical & Lighting Systems & Equipment to meet requirements of 701.5 . 31 '1'o the best of my knowledge, �1 . belief, & professional judyemettt- , these plates are 1.tt Or ol coutpliance with the code. uj *rF o�ftFESS% NP i *' BOARD OF IIRAi.TII . . . . . . . . . . . . . . . FORM NO. 1 3 SETS OF PLANS . . . . . . . . . . . . . . . TOWN OF SO11TtiOLD SURVEY . . . . . . . . . . . . . . . . . . . . . . . . BUILDING DEPARTMENT CHECK . . . . . . . . . . . . . . . . . . . . . . . . . TOWN iiAIJ, SEWT1C FORM . . . . . . . . . . . . . . . . . . . SOUTHOLD, N.Y. 11971 TEi.: 765-1802 NOTIFY: —Y?Yq CALL 7 l:xtxn i Fret].. !... 19.�?` MAIL TO: . . .. . . . . . . . . n�,rYw(cl -F `./1 ...., I91/2 Permit No. .. .................................... Dis.-rpproved a/c .................................. .................................... ............................................ .. ...... blilding inspector) APPL.ICATiON FOR BUILDING PERMIT Date. .. . . . . . . . . , 19.9.( iNSTRUCTI.ONS a. 'ibis application must be c(mpletely filled in by typewriter or in ink arx] strbnitted to the iltrilding inspector with "Insets of plans, accurate plot plan to scale. Fee according to sche(hrle. I). Plot planlslxxwing location of lot arxl of Wil.dings on premises, relationship to :)(]joining premises or ixiblis si:reets or areas, am] giving a detailed description of layout of property rust be drarwn on the diagram which is part of this application. C. 'lire work covere(1 Iry this application Fury not ire crnmenced before isst;ance of Building Permit. cl_ Ulxm approval. of this application, the D.ri.lding inspector will issue a llcrilding Permit to the applicant. S(rClr hermit shall be kept on the premises available for inspection thr(- rghout the work. P. No Wilding §ball be orcrrpied or (►.sect in wdxrle or in part for any ixrrpose whatever rmtil a Certificate of OCCI) Incy shall. have been granted iry Ow Building Inspector. Am.i(:i1f1.17N IS llE12TIIY MADE to the Wilding Department for the issuance of a 1krilding Permit prrsrrant to the iluilding 7cnre Ordinance of the Town of Sartlx)ld, Suffolk County, New York, aril other applicable Laws, Ordinances or Relrrlatiors, for the conslrtretion of 1xri1dirrj;s, ackliLions or alterations, or for removal or detmlition, as herein (described. T]re applicant agrees to comply with all applicable Laws, ordinances, brilding code, borrsing code, aril relnilaticxrs, arx] to admit atrLbori7ecl inspectors on premises atxl in lxr'l.dirrl; for cess i tions. . .. .. (SipiaLt re of. nppl.'.ant, or rtame, if a corporat ivo) � n Wal RIvfl, f UY1)7q t ./ (Mailing, -Kklress of appl.ican........ Stat whet applicant is owner, Lessee, agent, architect, engineer, general contracLor, electrician, plrrrirer. or Imilder. V�. � .......... .. ........ ........................................................................ R--litre of owwr of premises ."� Y ... OC� ................................................................ (as on the tax roll or latest deed) If applicant is a corporation, signahrre of ch,rly :nrttxrrize I off icer. ......................................................... Kilir aril title of corporate officer) lkrilders License No. !."'.�v './.�...... .... Pludrers license No. N1E'Y....!.LU�4jlV�.. Electricians License No. J g(9 3 -C-- ............... OUrer 'Trsxle's License Nc). .................... . 1. Location of Jarxl on wlridr prtirlxrr,ecd .work will Ire ckxre..i.!.`..0...... .... `!".':`."'�..b��v� La��� . 1I Xa Luve1wo�. �:hve La �. ..........................................................v! �....................._... Ilouse NFA er Stre//et ��]] 1 inlet +- Qxroty Tax PL, No. ()<)n Section !.-7 ...... mock .... .....•.. T.rrt ... ... SulAivision Q17 ..... ............... Filed Map No. ............... Lnt ._�.!.......... (t ur) 2_. State existing use arxJ occrrp.-nx-y of pr' ses aril inteolecl use aril oc:cupar •y of proposed ccrostnrcticm: a. Existing rise arxl occulvincY ..• 1.�.. �, ............................... V�C4 `j 1'QYhi h. lnletxkd tire aril crcc7rlrarrcy ................. ?. ........... ............................... ,r.. V 1. Nrlure of tn,tk (che(:k wluclr a1,l,licaIIle): tJcij Ikrilding ........ .. Acklilicxt .......... AlCe►aCion . . . ..... . . It pair ........ Itnrroval .......... ... I)O'KA ition ............ Other 4k,rk .................... .... .......... (Iksc:rlpCicx,) 4. 1?:il illiated (:os .............. . fee .............................. ... ............. (to Ix: laid cxr 1`i l iol; this appl icat ioo) 5. It: thoel 1 inl1, rar,be:r of ckael l inl; units ........�..._ tknber of ck0el I iog Ili,(cs cx, each floor .. �........... .. if garage, ranker of cars ............... ...... .............. .. . li. IF Ixrsirresa, canurercial or urixed occ-opara:y, specify oal.ure aril extent of each type of. use.......... .. .. . .. ... .. 1. I)ivansicxr:; of a/xiQs ng stnx_Urres, if any: Frool,.......... ....._ Itear .y.. .. ...... I)eptlr . .ell ...... .. ..... IkiglIL .......1.!............... Maher of Stories 01 .. .............. "Z -I �(fi I)ineosioos of s;rre stt►►cR,re uith alterlicxts or txklitions: Front ltear ........... . Iky,tlr ................. Ikliglrl .. ... ... Mn(,er of Slorie:; (1. Moitens►cxts of: eoL i ve rxla coosLr►x_l:ioo; Ficin ...ado..... .... Itear .._ .0........ I)epl l► . . ...... Ileit;Jrl: ..--t.................... Nnber of Storiet;�i..�...... ......... .. ��O vQ 9. size of lotl: Flora ✓LL�!!........ ...... Itear ^ I)eplh -.............. .... . E W 10. ILrte of llrrcha:ct! ..1.!.�.1.............. tJarrr! of Former (k4oer �...... . ........ ..................... 2 I I. Zooe or use district in mlricl► preruises are sit fated 12. Ikx!a prolx):;LA corrslrrxaioo violate any airing law, ordioaoce or regulation: . .!!.©................. , 11. Will lot he regraded ....'!'.'". '.....Q.. ... Will„excess fill be raiiovetl/,frctn pralils�es: YKS JD Irl. l4rrr s of t)urx r of I E. sea— '"??".!)dU LOC. /4klress (1P0'"'4V1�'C�jpc�1L/►r,� �.(�(,lio� ?-?�-�3 83 11 rcx,e [Ju. a � .�.�... .... l.a'S��� �ya ( i-ec�n off' �f77 f6-S Z N;nr! of Arcl,itecC Ackh as I'Irooe Nu. M ria of l cxrtractor r� ..;`u!�Q�`��.................. /4klress .1.!".... �l�v.k f!kk! t,S !l1,orx lk).`7 �`['�� �. f T h Is this prxtllerty within :1(X) feet of a tidal wetlarxl? * YI�1i .......... NO .L�... *II? v-s' S(XII1111) 'IfAM 112t1S111iS 17:1411'1. MAY ISI: Itl(�lllltl l). I'L0'1' MAGIIAH l.x:ate clearly and distinctly till Ixtildiogs, adtell►er existing or proposed, aril indicate all seL-IMWI( dimensions lieu prol,erty lilies. Give street aril block n►uber or descripticxi according to cleed,,arxl slrcaa street nines aril irxlicale %Aietlier interior or corner lot. l3 n+e'W1 t71rl�.;t;(,rn �qo� F. q �'``--,-� 41 �c LAOK�wood bh-ive :;rangy. tlr t+:w Yt>ttic, o4 n ss (111NIY (X - r 4/.4........ ........... .. ... . .. . ...... ... ..Ix:ing duty I'MAII, dcaxses aril says lhaL he is IIIc! applicant (lane of iodivichal signing cooll-act) ;rlx,ve runrecl, Ilk! i:; 111e .......... ................... ....... .......... .... (Cc)I,t.ractor, agent, corlx,rate officer, etc.) of: :;aid owrxlr or cmiers, arxl is duty auUrorizecl to lx!rfonn or have perFonrrld lire said work arxl to iiralee aril file Illk .rpl,licaLiou; l iaL all stat.erxoLs contairxld in this application are tioe to the Ixat of his krx,uledge teal aril that. the murk will he per-fortrrad in the uktnrrer set forth in the application filed ll►erewiUr. tk,orli to befoole lir! this . . .....a4-. r..d;t of: ..0e-7Z:Z.CO/9 ... /Appli .. ..... ........ LORETTA J. ERHARD (S igoa1 are l.) NOTARY PUBLIC,State of New York No.4795299 Qualified in Suffolk County Commission Expires A4are"O, 19 to = Ot IS 290 p0 COUiv^.'X : `r, A oT� . ,TIENT 1974- D. nDF, So f � n _. ?r �U y O_ ` ' ' S r fit been 3 l .•tmerlt and found GsssP .c t.� bo :at I �� t _ • II "i ^1 ssP�w L- ft. 3 �_ G�re�"' Y `Er 50� E , ,•^ OZOSQ Services rl',o pre° c UNAUTHORIZED ALTERATION OR ADDITION / t THE LOCATION OF WELLS AND CESSPOOLS ,lei( / S I TO TMSSURVCY 15 A VIOLATION OF N HEREIN ARE FROM FIELD / / V, SECnO 71Cs OF THE NEW YORK STATE ANDWOR FROM DATA OBTA NED FROM OTHERS S O i C FI'S CIFTI S MAP NOT BEARING E NK�D SEAL OR c ��A ! O AfO IC,..R.D ' \\ Z 0.0 O ET s 4 .Si�(610�V�PFLED/N THE OFR/CE �- 4$ of i CUA:A A .qf =.�N O'171£CLERKoFsto7�mKCOM"OV C��l'i T� 1 'Or.S 4F Sti;tVEY \� MAY 171971 AS f/LENO.5595. � � IS F6E:A LL KD HI c: �� i:: TNc � / IiT,C C Ati', 0\ i M EN At AGENCY AND • �/ / \p , Li P!G!I:G L.S :'i U':';N aST'C it..REON, AND ,V TO 1H` ASS'i•,L;.S �:F 1... c;NPING tNSTI- \ TUL'J> 'P F,4!: LEJ AnL N01 TLANSFEFABLE \ REVISIONS YOUNG & YOUNG APR. 15,1974 400 OSTRANDER AVENUE, RIVERHEAD, NEW YORK 20 SEPT.12,1974 '�J ALDEN W. YOUNG HOWARD W.YOUNG O Q— 05©IOIr• Lot PROFESSIONAL ENGINEER AND LAND SURVEYOR LAND SURVEYOR, N.Y.S. LIC. NO, 12545 N.Y.S. LIC. NO.45099 0 5.66 SURVEY FOR: ptc of k C ROBERT A.LOCKMAN 81 B N LOT NO.19, LAURELWO A to � lV E l KD < N p A AT KE TO LAUREL TY UARANTY 00. St $U31. S BAF ( TOWN OF F �T SOUTHOLD R=69.64;� �E Af SUFFOLK co., N.Y. err, oe , L=58 24 SCALE: 11 1 DATE: NO. I = 40 MAY 4,19 72 7:f-322 4IETZ"14 05 11646 - ovepip e Installation Items HomeSaver Stovepipe Shield The use of this handy Home- Saver Stovepipe Shield allows you to reduce required single- wall stovepipe clearances from 18"to 6". The Stovepipe Shield attach- r es to the pipe with the spacers _�� W and screws provided. This often eliminates the A. j need to attach a cumbersome HomeSaver Mantel St. shield directly to combustible surfaces nearby. This 24-ga.,black HomeSaver The 24-ga.black Stovepipe Mantel Shield attaches to Shield is half-round in shape, the mantel and allows a 35"long,and comes with clearance reduction from 18" mounting hardware. to 9"for stovepipe and from 36" j 10" One size fits all pipe diame- to 18"from the top of an ters from 5"—8".(55) unlisted stove. (For listed wic stoves, consult stove manual or con manufacturer.) mo Our Mantel Shield is 47" spa 16::. 4� wide,has a depth or"face"of tion It UL Listed Heat-Fab® Insulated HomeSaver® Heat Saf-T ThimbleT" Shield Spacers [ i With Screws And B The UL Listed Saf-T Thimble solid-pack in that tele- fl, 'i allows single-wall stovepipe to scopes inward toward the wall, Anchors a' pass through a combustible allowing for easy adjustment for 7 i wall. It attaches to the chimney wall thicknesses of 4"—81/2". These useful ceramic Spacers b therefore avoiding a dangerous Choose from 6"or 8" models. are 1" long and 9/16" in diame- ` Both need a 16"wide by 17" s breach should the chimney ter. a ( settle and start to pull away high opening for installation. They are sold in packs of 30 from the house. Instructions are included.(55) spacers and include 30,21/2" t The Saf-T Thimble features a long No. 10 screws,as well as i 30 plastic anchors. r Cast-Iron Stove- They come in a nice display t package that is sturdy enough pipe Damper to bang around in your truck, yet nice enough to be shown off '•` Even on today's airtight stoves in a retail setting. {; many people desire the"old- Use these Spacers when fashioned" Cast-Iron Stovepipe mounting Heat Shields.(57) i Damper which is located in the flue pipe.These Dampers come in 5"—8" diameters and have one-piece spring handles for convenient adjusting. (55) oc Price List 1 µ •- CLEARANCE TO COMBUSTIBLES CHART REAR OUTLET Sidewall, Backwall I 36" I r—f--- -------------I i I I I I 17" I I I I I ' I I s I I I I I I I I r I I - I I I I I I I I f I I I I I I I i I I ! I I � I 18„ 8" I I I f I L— ----------------� CLEARANCE TO COMBUSTIBLE SURFACES AND HEARTH EXTENSION FLOOR MAT Corner 36" i i i 36" i i v ,! !i NON ASBESTOS—FIRE RATED CLASS "A" 0614O11-110M HOMEX° 300 N .C.F. H.° HOMASOTE BuyLine0878 Expansion Joint Filler as Carpet Underlayment/UL Rated Wall Shield ;.� Al/Assembly, Installation GENERAL APPLICATION DATA Preparation for Use—Precondition panels by separating and allowing them to stand exposed to r ' normal environmental humidity for 24 hours before application. Panels larger than 4'x 8' w lit t should be lightly sprinkled with water and stacked ` u overnight,wet side up.Separate and allow them V- w to dry completely before installation. s � N.C.F R.' Homasote.as any quality wood budding material,will expand and contract with changes in 3 temperature and humidity.Gap butt joints and trim joints 3,6' as instructed in application instructions P�8-222 2. \��\ MF/Materials, Finishes Fire rated N.C.F.R.® Homasote is relatively light- weight,easy to work and handle.It can be cut, °n shaped and made to follow moderate bends without cracking or splintering.it can be attached PP/Product Presentation PP/Product Presentation to conventional framing with nails or by glue- Homex® 300 is a pre-molded treated wood fiber N.C.F.R.® Homasote is a Class"A"fire rated, nailing.The larger size panels will reduce strip for use in concrete and masonry joints to insulating,structural panel that meets the Fire application time and costs.N.C.F.R.® Homasote compensate for contraction and expansion caused Hazard Classification of the Underwriters is available with a fire retardant,authentic, by temperature change.Because of its resilient Laboratories, Inc.N.C.F.R.® Homasote is made decorative,tight-weave Burlap fabric surface and composition,Hci is installed neatly and with 100% recycled,all wood fiber material maintains its Class A Rating.It is also available easily,without danger of misalignment or completely impregnated with fire retardant prime coated on one side with white acrylic latex breakage. It will not extrude in hot weather nor chemical ingredients,treated for protection paint,with Class A rating. crack in cold weather.The natural gray color against termites, rot,fungi,and moisture blends with concrete to further enhance the absorption,and compressed into high density TSITechnicai Support appearance of the finished Ijob. structural weather resistant insulation board. UL LABEL UA/Uses,Applications UAIUses,Applications UNDERWRITERS' LABORATORIES, INC. Homex® 300 Expansion Joint Filler has been used Used as a Class A Fire Rated component in floor CLASSIFIER successfully in various installations ranging from and wall systems,as carpet underlayment and/or MINERAL AND FIBER BOARDS those measured in feet to those measured in as sound control material.Especially formulated Contents not over 500bd.ft. Forme Issue No.AV 649 miles. Homex® may be used in any building to conform to UL Standards for wall shields used FIRE HAZARD CLASSIFICATION construction where masonry or concrete walls behind listed and rated wood stoves,as covered Based on 100 for Untreated Red Oak meet outside aprons,walks,patios or steps. It by UL listing 91G7.It is weather resistant and NATURAL PRIMED also is ideal for swimming pool aprons,outdoor ideal for interior or exterior application where fire- FLAME SPREAD.......... 25 20 terraces,driveways and retaining walls.In general resistant materials are required.It is a tackable SMOKE DEVELOPED...... 20 0 construction, Homex® has been used success- interior paneling and is available prime coated on See U.L.Classtlled Building Materials Index luliv in airport runways,aprons and hangars;also one side without changing its Fire Hazard Classifi• in concrete floors and walls,bridges,tunnels. cation. it is perfect as a tackable substrate for CC/Codes,Certification viaducts.abutments, ramps, retaining walls, other fire-rated wall coverings such as vinyl or gutters,curbs and pavements. burlap. BSA Approval,New York City, Calendar No.540.72 SM OPlOverall Product in Place OP/Overall Product In Place BOCA Research Report#73-87 Sizes(nominal) Sizes(Nominal) UL Report No.R•5268 The basic material in Homex® 300 Expansion Federal Spec.SS-S-1 18A:Class"25" p Thick- Weight ICBG#1016 Joint Filler is all-wood fibers(with weather and neat sizes lb./sq.ft. Finish UL Canada—File#CR909 termite resisting additives)homogeneously formed into easilycut and shaped convenient) handled 4'x 4' P Y N.C.F.R.—used as a wall shield for reduced panels.Homex® is available in four preformed 4'x 8' natural or thicknesses,lengths to 10',and widths from 3"to '/x" 4'x 10' 1.5 primed white clearance behind heaters and stoves. g U L Listed 91 G7. 48'.Flatsheet Homex® is available in 4'width 4'x 12' and 10'length for fabrication to specified curb8'x 12' natural only Refer to Homasote Bulletin N-8.232.1 R for and gutter configurations—and for non-standard further details. sizes of expansion joint strips. Thicknesses Available and Joint Spacings In order to evaluate fire safety of a structure, building authorities Expansion upto 30' 50' 75' consider many factors including flame spread ratings. The best Joint Spacing 30' to5o' to75' to100' known flame spread test is the tunnel test, ASTM E-84. The follow- Recommended Y. Homex® Thick. %" �" �;• 1• ing table shows the flame spread index for each of the flame spread CC/Codes,Certification classifications: Homex® 300 conforms to performance require- ments of ASTM D-1751,U.S. FED.SPEC. TABLE 1: FLAME SPREAD RATINGS HH-F•341a Type I,and AASHTO Designation M-213.65.Homex® 300('/4'thick)meets ASTM D•2828-71 for non-bituminous contraction joint Flame Spread Flame Spread inserts. Classification Index j BOCA Research Report#84.65 Class I (or A) 0 to 25 �✓ SBCC Report#8653 See current Homasote Bulletin HX-8-211-1. Class I I(Or B) 26 to 75 Class I I I(or C) 76 to 200 7 LT Ill Girder pocket in II foundation wall O I I to accept 3) — 2 x 8 (t y p. � - 8'' thick poured concrete EXISTING STRUCTURE u! foundation, height to match ill existing foundation wall �os� _ f N Sk3y,ltAes�above EXISTING STRUCTURE Girder support pierlll q3q 0m L gaIt `r Ground poured f otings24'I below grade ! l 17\1 N to be at least 10'' wide ---------------- and 36 '' below grade l n AM�V✓" ! ---------------- N" G o 'I;; Install foundation vents as required yNpEItW�TEEQUA�iIFICATE III C •„' III 3046 3046 IIS I/ -;.T Pl EXISTING NEW EXISTING NEW / - V 9;OkS RUW-el h SHALL AAEI R' FLO0R PLAN ACDF THE N.Y. FOUNDATION P EAN CONSTRUCTION ` ENERGY ;,,nEs. NOT REs�onlslRLE ori IDEf;lGP➢OR CONSTRUCTION ERRORS Continuous ridge vent h� �'%d lr' Ridge beam (2) �7`P'=-stcet-fIE c plate, er, \Continuous soffit vent 2 x 8 roof rafters 16" on center double ® skylites 2 x 6 studs with (2) 2 x 8 window header R19 insulation 2 x 8 floor joists 16" on center Siding and cornice (z) z x s ccn to match existing mud sill S,// -5e,A Front Elevation ,etas W o Framing details 6 0 G W Q 4