Loading...
HomeMy WebLinkAbout48242-Z o, g�FFDL� 2k- % Town of Southold 3/25/2023 yP.O.Box 1179 r co Q, 53095 Main Rd co Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 48242 Date: 3/25/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 55 Eastward Ct.,Mattituck SCTM#: 473889 Sec/Block/Lot: 115.-7-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/20/2022 pursuant to which Building Permit No. 48242 dated 9/1/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwellingas applied for. The certificate is issued to Arklan,Turkan&Erkan of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48242 2/14/2023 PLUMBERS CERTIFICATION DATED t or' e Signature ��svFFoc,� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE y SOUTHOLD, NY h BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48242 Date: 9/1/2022 Permission is hereby granted to: Arklan, Aksu 55 Eastward Ct Mattituck, NY 11952 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 55 Eastward Ct., Mattituck SCTM # 473889 Sec/Block/Lot# 115.4-11 Pursuant to application dated 7/20/2022 and approved by the Building Inspector. To expire on 3/2/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING ' $50.00 Total: $200.00 Buil i nspector pF SO!/r�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(a-town.southold.ny.us Southold,NY 11971-0959 Q�yCOUNT`I,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Turkan Arklan Address: 55 Eastward Ct city:Mattituck st: NY zip: 11952 Building Permit* 48242 Section: 115 Block: 7 Lot: 11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: SunRun Installations License No: 33878ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency StrobeHeat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 19.125kW Roof Mounted PV Solar Energy System w/ (51) LR4 60HP 375W Modules 80A Fused Disconnect, Combiner Panel Notes: Solar Inspector Signature: G ate: February 14, 2023 S. Devlin-Cert Electrical Compliance Form oF souryo�o y ez yE s s a c # # TOWN OF SOUTHOLD BUILD NG DEPT. coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) I"-A ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C//O [ ] RENTAL REMARKS: Gk DATE INSPECTOR �� SOGIyOlo TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAAULKING [ ] FRAMING /STRAPPING [ FINAL 56 Ikke"" [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REM. KS: � 1/1 Ok - Nl�/ SL"--mA �-f 6 - 1 DATE INSPECTOR APR LA January 30,2023 Structural ENGINE TJ3 Subject: Post Installation Approval Letter INSTALL DATE 10-27-22 Job Number: ; Rev: B1 PERMIT#48242 Client: Erkan Arklan Address: 55 Eastward Ct, Mattituck, NY, 11952 Attn:To Whom It May Concern The purpose of the review was to verify the installation is in conformance with the permitted plan set and that any potential modifications from those plans meet the intent of the permitted plan set. The PV racking system's attachments have been observed to be installed in conformance with the permitted plan set.The installation complies with the code provisions listed below. •2020 NEW YORK STATE RESIDENTIAL CODE WITH 2018 IRC/IBC/IEBC,ASCE 7-16, NDS 2018 •Basic Wind Speed V= 128 mph, Exposure: B •Ground Snow Load=25 psf OF NEIN K'zq ctiF0 i C� Paul Zacher,P.E. �,o P�91nb- Professional Engineer ROFESSIONP� T:916.961.3960 x101 email: paul@pzse.com 03/24/2023 FIELD INSPECTION REPORT-F DATE COMMENTS O'4 � N � FOUNDATION(IST) ,t y N � ------------------------------------- FOUNDATION (2ND) vl m ROUGH FRAMING& PLUMBING 4 y /T V l I 1 INSULATION PER N.Y. STATE ENERGY CODE 9 —a FINAL ADDITIONAL COMMENTS *:::T -7 1 22 - a'd X 200 rq--e-G l 016 4 f A rn C GJ t� � ro N � o z x d b TOWN OF SOUTHOLD-BUILDING DEPARTMENT xy _: Town Hall Annex 54375 Main Road P. O. Box 1179 Southold;NY 11971-0959 04 • a� Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only C PERMIT NO. Building Inspector: JUL 2 0 2022 Applications and form's must,be filled out-in their..entirety. Incomplete, BUILDING DEPT. lications will not be,acce ted. Where the A licant is not the,6wner'an� TOWN OF SOUTHvLD a Pp. P Pp ,.. .. .. Owner's Authorization,form(Page 2)shall:be completed.' Date: C OWNERS) F'PROPERTY: Name: � //� ��/ SCTM#1000- 000 Project Address: Lasll ( ck Phone#: b5 _5o( _ 33 Email: avl6l n h Cul ' CC Mailing Address: 5's FCO(,t a CONTACT PERSON: Name: ,U r - Mailing Address: (V Q Ck-PC/, &/JLl ( p J )! 5-(—) . Phone#: ��Z ` Email: (,j DESIGN PROFESSIONAL INFORMATION: l ,,, ,/ Name: P2sr— ���/ r✓I�P�e1� - aUl 2ne-hI � Mailing Address: Phone#:v!1(0, q01. 12)q too Email: 601 CONTRACTOR INFORMATION: Yyn Name: rt/n ��rlSk tict',jam 1 1 M 2ilVI U S Mailing Address: 0-7 ct Dc/c 1 0 sl) Phone#: ��, (� /y. 7�1 r Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: POther e,f S 1 $ Will the lot be re-graded? ❑Yes No Will excess fill be removed from premises? ❑Yes ® fO-" 1 PROPERTY INFORMATION _ Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®118' IF YES, PROVIDE A COPY. ❑ Check Box After'Reading:":Th"e'owner/confracto?/design professional is responsible for all drainage and storm water issues as provided by ?, Chapter 236.6f the Town'Code:APPLICATION is HEREBY MADE to the Building Department for the issuance.of a'Building Permit pursuant to the Building Zone ordinance of the Town'of Southold,Suffolk,County,New York and other applicable 6w's,'Ordinances or Regulations,for the construction of buildings; additions,alterations or for removal or demolition as herein described.The applicant,agrees to comply with all applicable laws,ordinances,building code; housing code and regulations and to admit authorized inspectors on premises and In", for necessary inspections.False statements made herein are . punishable as a Class A misdemeanor pursuant to Section 210.4s of the New,York State Penal Law: Application Submied By(print name): uthorized Agent El Owner Signature of Applican . Date: � ' 012,2_ STATE OF NEW YORK) CONTY OF I / ) Y "f being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)heisthe "Aq T b0aQ L&- Je_ voci2f (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ) day of") 20_�� Not u c NICOLE GIORGET 1 Notary Public-State of New York NO.01G16292933 ROPERTY OWNER AUTHORIZATION Qualified in suffoik Co,nty My Commission Expires No, ;2. 2025 (Where the applicant is not the owner) I, � residing at do hereby authorize S� °� � to apply on my behalf to the Town of Southold Building Department for approval as descri ed herein}. Owner's Signature Date / NICGLE .ORGETT: FMyNotary P-blic-State of New York Print Owner's Name NO.OiG16292933 Qualified in Suffolk Courtyomm:ss'o,Expi,es Nov '2. 2025 2 6 ) S ' 1 I `KL- �uEl'Oe� BUILDING DEPARTMENT-Electrical Inspect®r _ TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 ®Ap�� Telephone (631) 765-1802 - FAX (631) 765-9502 rogen-Asoutholdtownny gov -- seanditsouthbldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INORMATION (Ail Information Required) Date: Company Name. Cyr Electrician's Name: License No.: Elec. email: L/ Elec. Phone No: . 7 ❑I request an 6mail copy of Certificate of Compliance Elec. Address.: l LZ d JOB SITE INFORMATION (All Information Required) Address: 57 f JJu1akrl 0A �- Cross Street: Phone No.: Bldg.Permit#: S Z L4 2 . email: Tax Map District: 1000 Section: 11L Block: Lot: / BRIEF DESCRIPTION OF WORK, INCLUDESQUARE FOOTAGE (Please Print Cle, rly): 6�� 074 C5-� Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES NO ®Rough In ❑ Final Do you need a Temp Certificate?: F—] YES �O Issued On Temp Information: (All information required) Service Size❑1 PhF-�3 Ph Size: A # Meters Old Meter# New Service®Fire Reconnect[]Flood Reconnect[]Service Reconnect Underground Overhead #Underground Laterals 1 2 D H Frame Pole Work done on Service? Y N Additional information: PAYMENT DUE WITH APPLICATION S � vacant I MAIN z,: ROAD MKS Rte'25) \� I e1 =27A I S.87",39 20'£ In elApg.o 205.82' O � Aouse V _s,.� W 110-�LIEIL,12 'ilhin/p0� — ---- �� 2 6 �.-10 �. \ \ M NO\\.... O ■=MONUyf£NT .. .. ..:: SUBO/V/SlON MAP FILED!/Y TN£OFf/C£O,F THE CLERK OF SUFFOLK COUNTY ON JUN£ Fie -mr36os - ._.; A/Rll- NEAREST-WATER MAIN 4MILES f \ WA7ER SUPPLY PR/VA7E WELLS � N.87`3920'H! �,�6• "ice -a THE LOCAT N OF N /9697' OBSERVATIONS ANDD/OS FROM DATA OBTAINED FROM OTHERS. FIELDDREVISIONS YOUNG & YOUNG THE WATER SUPPLY AND SEWAGE DISPOSAL SYSTEMS FOR THIS RESIDENCE WILL JULY „ /977 400 OSTRANDER AVENUE, RIVERHEAD, NEW YORK CONFORM TO THE STANDARDS OF THE SUFFOLK COUNTY DEPARTMENT OF HEALTH LOt 2 SERVICES ALDEN W.YOUNG HOWARD W.YOUNG AFFUCANT ---- - --- --------._. .. ..............�. .. .._ ENGINEER-ANO . - -LAND•eURVCYOR'_ _ .. .. .- ._...... _.�.. ... ....PROFESSIONAL ._. .. ADDRESS—————--—— ——— — ———--- LAND SURVEYOR.N.Y.S.LIG NO.12848 N.Y.B.LIC.NO.48009 -------- ------ SURVEY FOR: �PZE OF A,Fw UNAUTHORIZED ALTERATION OR ADDITION TO P. p &. LA THIS SURVEY IS A VIOLATION OF SECTION CAROL M M/ESNER ?O�P�D LY lO�4� TEOS OF THE NEW YORK STATE EDUCATION "W LOT NO./ EASTWARD MANOR; , ' $e h y COPES OF THIS SURVEY NAF HOT L RING She sewage disposal a-rid Tatar supplyv LA THE LAND SEAL SNA!J INKED SEAL OR facilities for t`tfa loc2l.icII 11EVa been EOBossEO SEAL 9NALL NOT BE CONSIDERED h OIIt and f0U718 /}A * TO BE A VALID TRUE GOPK AT GUARANTEED TO: Anapected by this d �� •_ MATT/TUCK to be satisfactory. /J�Mj��j/+��, w GUARANTEES INDICATED HEREON SHALL RUN e '/ •I W :D THE PARED,FOR WNHI THE TOWN OF f1��MOL. e� QFj$93- TOTH T PREPARED,AND ON HIS BEHALF .SW TIZOL� Chief of General SII$1neE/21 TO THE TITLE COMPANNDINQ Y,DOYERNNELIST �EC L1AID 511R1I c��6 AGENCY-AND ER N AANDITo'THE ASSIONCESNOF THE SUFFOLK-CO., N.Y. ED Services LENDING INSTITUTION.GUARANTEES ARE NOY'TRANSFERA R.R TO ADDITIONAL SCALE; DATE: NO. INSTITUTIONS OR SUBSEQUENT OWNERS. /"=40' NOY.3,/976 764958 ..S ti92q 2 sunrun DEU 0T '' 177 Cantiague Rock Road LD Westbury NY 11590 LiPermitsCabsunrun.com 12/2/2022 RE:As Built plans Permit DASH 55 Eastward Ct., Mattituck, NY 11952 The following revisions have been made to the plans: Switching to (51) Longi 375. Thank you, Michele Cardon Sunrun permit coordinator voeK Workers' CERTIFICATE OF INSURANCE COVERAGE STATE_ Compensation - Board=------ -DISABILITYAND-PAID-FAMILY-LEAVE-BEN EFITS-LAW-- - — ---- -- -- - PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier la.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Sunrun Installation Services Inc. ($45) 268-2595 595 Market Street 29th Floor , San Francisco,CA 94105 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to certain or Social Security Number locations in New York State,i.e.,Wrap-Up Policy) 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) The Prudential Insurance Company of America Town of Southold 3b.Policy Number of Entity Listed in Box"l a" 54375 Route 75 CG-52830-NY P.O. Box 1179 Southold, NY 11971 3c.Policy effective period 01/01/2022 to 12/31/2022 4. Policy provides the following benefits: ❑X A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policycovers: ❑X A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date signed January 19, 2022 By signature of iii u&aricecarrier's a`ut6rized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number (215)784-2883 Name and Title Vice President,Contracts IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 413,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit, PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 111111IP1°°°1°°°°1°°1°°°°1°°°°°�IIIIIII 5 YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE ------------- ---- -Boar --- -------- -----—--- - ------ -- - - - 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. (415)946-7500 225 Bush Street,Suite 1400 1 c.NYS Unemployment Insurance Employer Registration Number of San Francisco,CA 94104 Insured 50-864264 Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) AMERICAN ZURICH INSURANCE COMPANY Town of Southold 3b.Policy Number of Entity Listed in Box"la" Town Hall Annex Building 54375 Route 25 WC 6142876-00 P O Box 1179 Southold,NY 11971 3c.Policy effective period 10/01/2021 to 10/01/2022 3d.The Proprietor,Partners or Executive Officers are 0 included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"la"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Samantha Furlan (Print name of authorized representative or licensed agent of insurance carrier) Approved by: I an� 1P;:_a416UL 0?-2_2_-2_02-1 (Signature) (Date) Title:Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier: (415)538-7125 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov r ' SUNRINC-02 TWANG CERTIFICATE OF LIABILITY INSURANCE DATE A E(MMI DN ) _THIS CERTIFICATEJS_ISS_UED_AS__A_MATTER_OF_INF.ORMATION_ONLY_AND.CONFERS_NO RIGHT_S_UP_ON_THE.CERTIFICATE.HOLDER.THIS__ CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER cANONT MEACT Walter Tanner . Alliant Insurance Services,Inc. PHONE FAX 575 Market St Ste 3600 A/c,No,Ext): A/c,No): San Francisco,CA 94105 EA -MIL ,Walter.Tanner@alliant.com INSURERS AFFORDING COVERAGE NAIC# INSURERA:Navigators Specialty Insurance Company 36056 INSURED INSURER 13:Zurich American Insurance Company 16535 Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURER D: San Luis Obispo,CA 93401 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP R TYPE OF INSURANCE D POLICY NUMBER D DD LIMITS A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2'000'000 CLAIMS-MADE FX OCCUR LA21CGL2303211C 10/1/2021 10/1/2022 DAMAGE TO RENTED 1,000,000 MED EXP(Any oneperson) $ 5'000 PERSONAL&ADV INJURY $ 2'000'000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE 2'000'000 X POLICY�X JECT F-1 LOC PRODUCTS-COMP/OP AGG 2,000,000 X OTHER:Retention:$100,000 Per Project Agg $ 10,000,000 MBINED SINGLE LIMIT $ 2,000,000 B AUTOMOBILE LIABILITY CO X ANY AUTO BAP614287700 10/1/2021 10/1/2022 BODILY INJURY Perperson) $ OWNED SCHEDULED AIURTEOpS ONLY AUTNOSSWNEp BODILY INJURY Per accident $ AUTOS ONLY AUTOS ONLY Perr acEciRdent AMAGE X F950Ded.: Ix Coll.:Not Covered Liability Ded.: $ 250,000 UMBRELLA LtAB HOCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE DED I I RETENTION$ $ C WORKERS COMPENSATION X PER OTH- ER AND EMPLOYERS'LIABILITY C614287600 10/1/2021 10/1/2022 ER 1,000,000 ANY PROPER/M IMO�EXCLUE[E ECUTIVE Y� NIA E.L.EACHACCIDENT 1 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ '000'000 If yes,desoibe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Workers'Compensation Policy WC614287600 Deductible:$1,000,000. Evidence of Insurance CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Townof Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Route h ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE . k ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD 3. S', -01 g 4 T ­1�0# i:;,7 _J_ < M A ir.......... .. g Suffolk County Department of Labor, Licensin & 5 - 21fir; Consumer Affairs M, Nt VETERANS'MEMORIAL,MGHWAY HAUPPAUGE,NEW YORK 11788 I DATE ISSUED: 10/1/2003 NO. 33878�-ME M Z_ SUFFOLK COUNTY Master Electrician License M r. rj 11 1 fN This is to certify that SAMY A MOUNAS: A A, doing business as 112520;R �i INSTALLATION SERVICES INC ,,it; having given satisfactory evidence of competency,ishereby licensed as MASTER ELECTRICIAN in accordance with and"subject to the provisions of applicable laws,rules and regulations of the Cnty of Suffolk, . State of New York. ou1".. 01"i'l Additional Businesses NOT VALIOD WITHOUT DEPARTMENTAL SEAL 4 I'N S IN ANDA CURRENT jlil CONSUMER AFFAIRS a ID`CARD -42005N ok., w Acting Commissioner n. NI's i F, ........... -I5. f; 7, i 0 VAC SINGLE SINGLE PHASE SOLAREDGE TECHNOLOGIES: SERVICE SE380OH-USMN WITH METER#: REVENUE GRADE METERING M PSEGLI 98302662 3800 WATT INVERTER JUNCTION BOX PV MODULES ACCOUNT#: 2a OR EQUIVALENT 1a LONGI GREEN ENERGY TECHNOLOGY UTILITY NOTE:TOTAL PV BACKFEED=73A GRID 9621053200 USED FOR INTERCONNECTION qLOADRATED �� + // CO LTD:LR4-60HPH-375M SUPPLY SIDE TAP CALCULATIONS OPTIMIDULES OPTIMIZERS WIRED IN: (N)100A PV LOAD (1)SERIES OF(11)OPTIMIZERS CENTER C DISCONNECT PID SHUTDOWN SOLAREDGE POWER OPTIMIZERS P401 (N)LOCKABLE 3a 1 SOLAREDGE TECHNOLOGIES:EXISTING 200A BLADE TYPE MAIN BREAKER FUSED AC (N)LOCKABLE SEt0000H-USSN WITH 1 DISCONNECT BLADE TYPE v REVENUE GRADE METERING AC DISCONNECT 10000 WATT INVERTER JUNCTION BOX PV MODULES EXISTING 4 4 3b 2b OR EQUIVALENT 1b LONGI GREEN ENERGY TECHNOLOGY 225A MAIN CO LTD:LR4.60HPH-375M (40)MODULES PANEL — OPTIMIZERS WIRED IN: FACILITY 80A FUSES (1)SERIES OF(14)OPTIMIZERS LOADS r 0 1 SERIES OF 13 OPTIMIZERS SQUARED SQUARED 20A BREAKER(A) LOAD RATED DC DISCONNECT () ( ) D223NRB DU323RB 60A BREAKER(B) WITH AFCI,RAPID SHUTDOWN (1)SERIES OF(13)OPTIMIZERS 3R,100A 3R,100A,2P COMPLIANT SOLAREDGE POW OPTIMIZERS 120/240VAC 1201240VAC P401 CONDUIT SCHEDULE 1 # CONDUIT CONDUCTOR NEUTRAL GROUND 1 a NONE (2)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER s u n r u n 1b NONE (6)10 AWG PV WIRE NONE'' (1)6 AWG BARE COPPER 2a 1"PVC OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 2b 1"PVC OR EQUIV. (6)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 00825-ME 3a 1"PVC OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 15O TfEAYE.Hl-NY11- PHONEBBS.BW.- FMW2682M 3b 1"PVC OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 CUSTOMER RESIDENCE: ERKAN ARKLAN 4 1"PVC OR EQUIV. (2)4 AWG THHN/THWN-2 (1)8 AWG THHNrrHWN-2 (1)8 AWG THHN/THWN-2 55 EASTWARD CT,MATTITUCK, NY,11952 =�LR4-60HPH-375M: 375 ARA TERISTI S P370 OPTIMIZER CHARACTERISTICS: TEL.(631)506-9933 EN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:1000.115-00.07-00-011-000 GY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: 375M: 375 W MAXINPUT ISC: 11ADC 216R-055ARKL UIT VOLTAGE: 41.1 V MAX OUTPUT CURRENT: 15ADC VOLTAGE: 34.6 VUIT CURRENT: 11.6 A DESIGNER: (415)580 6s20 ex3 1 SYSTEM CHARACTERISTICS-INVERTER 2 SOHAN SINGH SYSTEM SIZE: 4125 W SYSTEM SIZE: 15000 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 11 V SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:B1 10/28/2022 SYSTEM OPERATING CURRENT: 10.86 A SYSTEM OPERATING CURRENT: 37.5 A SYSTEM SHORT CIRCUIT CURRENT: 15A SYSTEM SHORT CIRCUIT CURRENT: 45A PAGE PV-4.0 Astra v.1.741 November 8,2022 RE CAT 4 structural Subject:Structural Certification for Proposed Residential Solar Installation. ENGINEERS Job Number:216R-055ARKL;Rev B1 Client:Erkan Arklan Address:55 Eastward Ct,Mattituck,NY,11952 Attn:To Whom It May Concern A field observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun.Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: •2020 NEW YORK STATE RESIDENTIAL CODE WITH 2018 IRC/IBC/IEBC,7-16 ASCE$2018 NDS •Basic Wind Speed V=128 mph,Exposure B •Ground Snow Load=25 psf Based on this evaluation,I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally,I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summa Hardware Check Includes Uplift Check on Attachments/Fastener,Structure Check Considers Main Structure Orientation Attachment Spacing/Cantilever Configuration Max DCR Result Landscape 72/28 Staggered 57% j Pass AR-01 Portrait 48/22 Staggered 70% I Pass Roofing Material Pitch Structure Check Comp Shingle 19• t Pass Orientation Attachment Spacing/Cantilever Configuration Max DCR Result Landscape 72/28 Staggered 57% Pass AR-02 Portrait 48/22 Staggered 70% Pass Roofing Material Pitch Structure Check Comp Shingle 19• Pass a OF NEL7,Y K. Zq O CO :u 195:.W xP�13652 AR�FESSIONP� Paul Zacher,P.E. 1478 Stone Point Dr.Suite 190,Roseville,CA,95661 P (916)961-3960 Professional Engineer T:916.961.3960 x101 E-mail:paul@pzse.com SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE N DESCRIPTION •SYSTEM SIZE:19125W DC,13800W AC •ALL WORK SHALL COMPLY WITH 2020 NEW YORK STATE RESIDENTIAL CODE SOLAR MODULES MODULES:(51)LONGI GREEN ENERGY TECHNOLOGY CO WITH 2018 IRC/IBC/IEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS SE SERVICE ENTRANCE PV-1.0 COVER SHEET LTD:LR4-60HPH-375M AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN INVERTERS:(1)SOLAREDGE TECHNOLOGIES: PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. SE3800H-USMN,(1)SOLAREDGE TECHNOLOGIES: MP MAIN PANEL PV-3,0 LAYOUT SE10000H-USSN ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV 4.0 ELECTRICAL RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEALSNR MOUNT TRACK ON COMP,SEE DETAIL SNR-DC-00436 •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. Q ATTIC VENT OF NEt1. •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT K.ZA 0,p MODULES,ARE CLASS A FIRE RATED. 0 PVC PIPE VENT y Fp •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) 0 METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T-VENT CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AO AC DISCONNECT(S) �1365- P� Q SATELLITE DISH OfESSION ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC ® For Structural Only O DC DISCONNECT(S) FIRE SETBACKS •11.6 AMPS MODULE SHORT CIRCUIT CURRENT. •18.12 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB 10 COMBINER BOX CEJ HARDSCAPE F_7 INTERIOR EQUIPMENT —PL— PROPERTY LINE L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION 00825-ME Integrity nl aDC DIRECT CURRENT E EXISTING SC MO EAVE,MI XSV LLE NY 11101 Machine Works ESS ENERGY STORAGE SYSTEM , MC EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC ERKAN ARKLAN Shamrock Christmas MSP MAIN SERVICE PANEL 55 EASTWARD CT,MATTITUCK, Tree Farm (N) NEW NY,11952 NTS NOT TO SCALE _ OC ON CENTER TEL.(631)506-9933 55 Eastward Ct, Mat PREFAB POUNDS PPRE-FABRIER SQUARE FOOT CATED APN:1000-115-00-07-00-011-000 PV PHOTOVOLTAIC PROJECT NUMBER: L25 - Mattituck, NY 11952... RSD RAPID SHUTDOWN DEVICE 216R-055ARKL TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL V VOLTS SOHAN SINGH W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:Bi 10/28/2022 PAGE PV-1.0 3rrE PLAN-SCALE-31W.1I•-0" SrrE PLAN DETAIL-SCALE=1/64"=V-0" ARRAY TRUE MAG PV AREA PITCH AZIM AZIM (SOFT) ® AR-01 1 19° 1 262° 274° 490.2 AR-02 1 19° 1 82° 94° 509.8 (E)FENCE s>L GROUND FIRE SETBACKS ACCESS POINT (18•TYP) (E)RESIDENCE A ROOF PATHWAYS (3,TYP) w�y sez ' � ) (E)GATE PL - d (N)ARRAY AR-02 (N)ARRAY AR-01 sunrun 00825-ME 15 CI OM AVE.NIC1f8VILLE NY 11.1 PMOIE 000.610.6M) FA%l06.1YJOT! ROOF PATHWAYS CUSTOMER RESIDENCE: (3-TYP) ERKAN ARKLAN 55 EASTWARD CT,MATTITUCK, NY,11952 NTN LC�C� L �O�J TEL.(631)506-9933 APN:1000.11500-07-00-011-000 OF NE/y y PROJECT NUMBER: SMP GROUND Y.ZACy 0 216R-055ARKL ACCESS POINT Cli F,p AC DESIGNER: (415)580-6920 ex3 SOHAN SINGH P�13652 SHEET sswNP� SITE PLAN For Structural Only REV:B1 10/26/2022 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X4 CARPENTER TRUSSES T-6- 24" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 4'.0- 1'-10" STAGGERED 128 MPH 3-SEC GUST. S.S.LAG SCREWS: RL UNIVERSAL,SPEEDSEAL TRACK ON5/16":2.5"MIN EMBEDMENT AR-02 COMP SHINGLE-RLU 2-Story 2X4 CARPENTER TRUSSES T-6' 24" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 4'.0- 1'-10" STAGGERED STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY DI-AR-01-SCALE:1/8"=Vo.. ENGINEER OF ANY POTENTIAL AZIM:262' STRUCTURAL ISSUES PITCH:19• OBSERVED PRIOR TO 40'-8' —5'-21 PROCEEDING W/ INSTALLATION. 1,-6' • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), 6'-10" THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG 6'TYP— REDUCED WITHIN THE 12" 13'-10" BOUNDARY REGION ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT 7-8" SPACING INDICATED ON PLANS TO BE REDUCED BY 50% 9' i ••ALLOWABLE OVERHANG }-3'- 29' 16'-9" { INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:1/8"=V-0" AZIM.82° s u n r u n PITCH:19° 00825-ME 15 CXAILLOTTE AVE.NICx9NLLE HY ttpl �+orE amsw.wr 1 ty: EAx w.aae.mn CUSTOMER RESIDENCE: ERKAN ARKLAN 55 EASTWARD CT,MATTITUCK, 3•-6" NY,11952 13'-10' I 6'TYP— TEL.(631)506-9933 APN:1000-115-00-07-00-011-000 OF NEIyY PROJECT NUMBER: o �K ZA ..0p 216R-055ARKL 6" 1 * DESIGNER: (415)580-6920 ex3 -}3'-3' 23'-3" 11'-7" -4'-10"-{ W SOHAN SINGH 40'-8' Pop SHEET LAYOUT SsloeP` REV:B1 10/28/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 1201240 VAC SINGLE PHASE SOLAREDGE TECHNOLOGIES: SERVICE SE380OH-USMN WITH REVENUE GRADE METERING METER#: 3800 WATT INVERTER JUNCTION BOX PV MODULES M PSEGLI 98302662 OR EQUIVALENT e 1a LONGI GREEN ENERGY TECHNOLOGY NT ACCOU #: UTILITY NOTE:TOTAL PV BACKFEED=73A / CO LTD:LR4-60HPH-375M GRID 9621053200 USED FOR INTERCONNECTION FLOAD / (11)MODULES SUPPLY SIDE TAP CALCULATIONS --- OPTIMIZERS WIRED IN: (1)SERIES OF(11)OPTIMIZERS (N)100A PV LOAD RATED DC DISCONNECTCENTER AFC"RAPID SHUTDOWNSOLAREDGE POWER OPTIMIZERS LIANT 1401 (N)LOCKABLE 3 SOLAREDGE TECHNOLOGIES: 1 EXISTING 200A BLADE TYPE MAIN BREAKER FUSED AC ( )N LOCKABLE SE10000H-USSN WITH DISCONNECT BLADE TYPE v REVENUE GRADE METERING J AC DISCONNECT 10000 WATT INVERTER JUNCTION BOX PV MODULES 4 3b 2b OR EQUNALENT 1b LONGI GREEN ENERGY TECHNOLOGY EXISTING / CO LTD:LR4-60HPH-375M /\ 225A MAIN — �� `r �/. +hi// (40)MODULES PANEL " — �/ OPTIMIZERS WIRED IN: FACILITY 80A FUSES (1)SERIES OF(14)OPTIMIZERS LOADS o SQUARED SQUARED 20A BREAKER(A) LOAD RATED DC DISCONNECT (1)SERIES OF(13)OPTIMIZERS D223NRB DU323RB 60A BREAKER(B) WITH AFCI,RAPID SHUTDOWN (1)SERIES OF�13)OPTIMIZERS 3R,100A 3R,100A,2P COMPLIANT SOLAREDGE POW R OPTIMIZERS 1401 120/240VAC 120/240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1a NONE (2)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER s u n r u n 1b NONE (6)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 2a 1"PVC OR EQU IV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 2b 1"PVC OR EQU IV. (6)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 00825-ME 3a 1"PVC OR EQU IV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)B AWG THHN/THWN-2 o MICKeNLLE NY tIIOt cox e.s.xe.ma 3b 1"PVC OR EQU IV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHNrrHWN-2 CUSTOMER RESIDENCE: ERKAN ARKLAN 4 1"PVC OR EQU IV. (2)4 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 55 EASTWARD CT,MATTITUCK, NY,11952 MO ULE C ARA TERISTI S p370 OPTIMIZER CHARACTERISTICS: TEL.(631)506-9933 LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:1000-115-00-07-00-011-000 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC LR4-60HPH-375M: 375 W PROJECT NUMBER: OPEN CIRCUIT VOLTAGE: 41.1 V AX INPUT ISC: 11 ADC 216R-055ARKL MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE: 34.6 V DESIGNER: (415)580-6920 ex3 SHORT CIRCUIT CURRENT: 11.6 A 1 SYSTEM CHARACTERISTICS-INVERTER 2 SOHAN SINGH SYSTEM SIZE: 4125 W SYSTEM SIZE: 15000 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 11 V SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:B1 10/28/2022 SYSTEM OPERATING CURRENT: 10.86 A SYSTEM OPERATING CURRENT: 37.5 A SYSTEM SHORT CIRCUIT CURRENT: 15 A SYSTEM SHORT CIRCUIT CURRENT: 45 A PAGE PV-4.0 INVERTER 1 NOTES AND SPECIFICATIONS: &WARNING --EWARN I •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE PHOTOVOLTAIC • 1 • 110.21(6),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM IF REQUESTED BY THE LOCAL AHJ. COMBINER PANEL MAXIMUM SYSTEM VOLTAGE: 480VDC SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD DO NOT ADD LOADS 15 ADC •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED INMAX RATED F THE CHARGE METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION LABEL LOCATION: OUTPUT • I LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PHOTOVOLTAIC AC COMBINER(IF CONTROLLER•_DC-TO-DC C• INSTALLED15 ADC, INVOLVED. APPLICABLE). L SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY LABEL LOCATION: PER CODE(S):NEC 2017:705.12(B)(2)(3)(c) SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),AC/DC DISCONNECT(S), LABEL LOCATION: .DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). PER CODE(S):NEC 2017:690.13(8) PER CODE(S):CEC 2019:690.53,NEC 2017:690.53 Q! WARNING INVERTER2 DUAL POWER SUPPLY PHOTOVOLTAIC DC DISCONNECT POWER SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID • a80 1 DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC 45 •/ OVERCURRENT DEVICE SYSTEM RATEDMAX OUTPUT CURRENT OF THE CHARGE LABEL LOCATION: LABEL LOCATION: CONTROLLER••DC-TO-DC C• 1 IS •• ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. LABEL LOCATION: PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:705.12(BH3) INVERTER(S),DC DISCONNECT(S). 7D5.12(BX2)(3)(b) PER CODE(S):NEC 2017:690.53,CEC 2019:690.53 NOTICE •� • �• PV SYSTEM COMBINER FOR SOLAR PV SYSTEM DO NOT ADD LOADS TO THIS PANEL LABEL LOCATION: INSTALLED WITHIN T OF RAPID SHUT DOWN SWITCH PER CODE(S):NEC 2017:690.56(C)(3),IFC BUILDING SUPPLIED BY UTILITY sunrun 2012:605.11.1,IFC 2018:1204.5.3 GRID AND PHOTOVOLTAIC 4., _ SYSTEM SOLAR PV SYSTEM EQUIPPED 00825-ME 15 CH-.HII-UE NY 1ILYTI- 1901 PHON M.M.- ' 014Lem • • • WITH RAPID SHUTDOWN FA%BM.Z•930Q •• • • • CUSTOMER RESIDENCE: LABEL LOCATION: ERKAN ARKLAN INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, 55 EASTWARD CT,MATTITUCK, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, NY,11952 ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. 3• TURN RAPID SHUTDOWN PER 0112: S):NEC 2017:690.31(G)(3),890.31(G)(4), SWITCH TO THE"OFF' ( ) IFC 2012:805.11.1.4HFd TEL. 831 506-9933 POSITION TO SHUT DOWN APN:1000-115-00-07-00.011-000 PV SYSTEM AND REDUCE PROJECT NUMBER: SHOCK HAZARD IN THE PV SYSTEM 216R-055ARKL PHOTOVOLTAIC AC DISCONNECTARRAY. DISCONNECT •• 1 . DESIGNER: (415)580-6920•x3 NOMINALOPERATING AC • 1 SOHAN SINGH LIBEL LOCATION: LABEL LOCATION: POINT OF INTERCONNECTION SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF LABEL LOCATION: (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) SIGNAGE INTERCONNECTION. ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2017:690.54 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:B7 10/28/2022 PER CODE(S):NEC 2017:690.56(CXIX•) PAGE PV-5.0 LR4-60HPH 350~380M NEWHigh Efficiency Low LID Mono PERC with Half-cut Technology 12-year Warranty for Materials ����■ and Processing; 25-year Warranty for Extra Linear Power Output 100% -0.55% 1 ' 25 year Power Additional yalUe from Warranty Annual LOAIr,,i Sol Power Attenuation 91.2% S� ar s Linear Warranh 0.55% 87.7% ndard M°duce linear power Warran 84.5% ty 80.7% 1 5 10 15 20 25 Complete System and Product Certifications Positive power tolerance(0 +SW)guaranteed IEC 61215,IEC 61730,UL 61730 ISO 9001:2008:ISO Quality Management System High module conversion efficiency(up to 20.9%) ISO 14001:2004:ISO Environment Management System Slower power degradation enabled by Low LID Mono PERC technology:first year<2%, TS62941:Guideline for module design qualification and type approval 0.55%year 2-25 OHSAS 18001:2007 Occupational Health and Safety Solid PID resistance ensured by solar cell process optimization and careful module BOM �L. selection c"us Reduced resistive loss with lower operating current * Specifications subject to technical changes and tests. Higher energy yield with lower operating temperature LONGI Solar reserves the right of interpretation. Reduced hot spot risk with optimized electrical design and lower operating current ■ NG' Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Pudong Shanghai,200120,China Tel:+86-21-80162606 E-mail:module@longi-silicon.com Facebook:www.facebook.com/LONGi Solar Note:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONGi have the sole right to make such modification at anytime without further notice;Demanding party shall request for the latest datasheet for such as contract need,and make it a consisting and binding part of lawful documentation duly signed by both parties. 2020041OV11 for US-D LR4-60HPH 350~380M OperatingDesign(mm) Mechanical Parameters 35 1038 _,..� T..r.:.. Cell Orientation:120(6x20) Operational Temperature:-40'C-+85 C -� luncton8coc:IP68,threediodes Power OutputTokranoe:0-+5W 9 ------ v Output Cable:4mm',1200mminlength Vocand lscTolerance:±3% 4.5 Glass:Single glass Maximum System Voltage:DC1500V(IEC/UL) 3.2mm coated tempered glass Maximum Series Fuse Rating:20A ^gP s 30 Frame:Anodized aluminum alley frame Nominal Operating Cell Temperature:45±2 C --- -- --... _. n n Weight:ght kg Safely Class:Class 11 ---_- -. - unlet m OrKlp Dimension:1755x1038x3Smm Fire Rating:ULtype 1 or 2 -- _ -_ Tol4.apQ: -- I 997 L aTh+2mm Packaging:30pcsper pallet 180pcsper 20'GP -- ---- Pitch rpx.«lmm ' - 780prsper40'HC Electrical Characteristics Test uncertainty for Pmax:13% Model Number LR4-60HPH-350M LR4-60HPH-355M LR4-60HPH-360M LR4-60HPH-365M LR4-60HPH-370M LR4-60HPH-375M LR4-60HPH-380M Testing Condition STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power(Pmax/W) 350 261.4 355 265.1 360 268.8 365 272.6 370 276.3 375 280.0 380 283.8 Open Circuit Voltage(Voc/V) 40.1 37.6 40.3 37.8 40.5 38.0 40.7 38.2 40.9 38.3 41.1 38.5 41.3 38.7 Short Circuit Current(Isc/A) 11.15 9.02 11.25 9.10 11.35 9.17 11.43 9.25 11.52 9.32 11.60 9.38 11.69 9.45 Voltage at Maximum Power(Vmp/V) 33.6 31.3 33.8 31.5 34.0 31.7 34.2 31.8 34.4 32.0 34.6 32.2 34.8 32.4 Current at Maximum Power(Imp/A) 10.42 8.35 10.51 8.43 10.59 8.49 10.68 8.56 10.76 8.63 10.84 8.69 10.92 8.76 Module Efficiency(%) 19.2 19.5 19.8 20.0 20.3 20.6 20.9 STC(Standard Testing Conditions):Irradiance 10OOW/m2,Cell Temperature 251C,Spectra at AM1.5 NOCT(Nominal Operating Cell Temperature):Irradiance 800W/m',Ambient Temperature 20 C,Spectra at AM1.5,Wind at 1m/S Temperature Ratings(STC) Mechanical Loading Temperature Coefficient of Isc +0.048%/C Front Side Maximum Static Loading 5400Pa Temperature Coefficient of Voc -0.270%/C Rear Side Maximum Static Loading 2400Pa Temperature Coefficient of Pmax -0.350%/C Hailstone Test 25mm Hailstone at the speed of 23m/s Current-Voltage Curve(LR4-60HPH-365M) Power-Voltage Curve(LR4-60HPH-365M) Current-Voltage Curve(1.114-6OHPH-365M) 12 400 Ce-p=25r 12 Cell Temp=25r 30 350 -100ow/m' 10 1000w/m' ncidentlmd=1000W/1' 300 Wow/t^' 600w/m' 90ow/m' Q 6 -Cell Temp=25C ; 250 400w/m' Q 9 -Cell Temp=35r . _ -200w/m' 600w/m' c 6 -Cell Temp=451C ; 200 6 -Cell Temp=55C V 4 -Cell Temp•65C 150 u 4 400w/m' -Cell Temp=75C 100 250 ,-= 2 201w/m' 0 0 r 0 0 10 20 30 40 50 0 10 20 30 40 50 0 10 20 30 40 50 Voltage(v) Voltage(v) Voltage(v) NGI Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Pudong Shanghai,200120,China Tel:+86-21-80162606 E-mail:module@longi-silicon.com Facebook:www.facebook.com/LONGi Solar Note:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONGi have the sole right to make such modification at anytime without further notice;Demanding party shall request for the latest datasheet for such as contract need,and make it a consisting and binding part of lawful documentation duly signed by both parties. 20200410V11for US-D DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins REVISION: PART NUMBER(S): 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 94105 USA PHONE(415)580-6900•FAX(415)580-8902 242-02155 THE VJFORMATIONIN OSURAWINOS C EREOF 1SP OWPROPRIETARY.ANY REPRODUCTION,'rrTE CO OR USE SUNRE FS PRONISREO WIIHOUTTHE WROTEN CONSENT OF SUNRUN 90UTH LLQ 10 5 0 0 4 3 9 a-4 8 1 2 o 6 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK, RL UNIVERSAL, LEVELER, MILL 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL 4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK 5 1 SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 1 SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS 8 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X IIN, SS 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1 BOLT, FLANGE, SERRATED, 3/8IN-16 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 623 UP, 674 DOWN, 505 SIDE ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.73 DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins SnapNrack- REVISION: PART NUMBER(S): A 595 MARKET STREET,29TH FLOOR.SAN FRANCISCO,CA 94105 USA PHONE(415)58M900.FAX(415)SW-5902 242-02155 THEINFORN MON INTHISDRAWINGISCONFIDENTIALANOPRCPRIETARY ANY REPRCOUCOON,OISMOSURE,OR USE THEREOF IS PROHISREO WRHOUTTHE ,WMN CONSENT OF SUNRUN SOUTH LLC. 1.50 3.41 1.50 Fs� 2.35 —� 1.50 —1.55- .66 L2.00 1.00 1.24 SLOT Sy 2.63 ALL DIMENSIONS IN INCHES solar=@@ Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US/SE1140OH-US I 6 I _ _ 0 - X11 solar=a- Yi71r�WovC �) solar=11 Y;1^wave i rhe• 25 mac; w • ♦ m _m a oil, f Optimized installation with HD-Wave technology - Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation wave Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us so I a r " • e Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/ SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/ SE1000OH-US/SE1140OH-US SE3000H-US I SE380OH-US SE5000H-US I SE6000H-US SE760OH-US I SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA ,•„••,•„„ 3300,9208V„-,.,-,-,-„ 5000,�208V ............................................ . ....-.......... ................ .....-.......... ........... 3800 @ 240V Max.AC Power Output 3000 5000 6000 @ 240V 7600 10000 11400 VA 3300 208V 5000 208V AC Output Voltage Min.-N om:Max. ✓ - ✓ Vac X183„208„229)......................... .............. ................ ............... . ....... AC Output Voltage Min.-Nom.-Max. (211,=240„264)......................... ............... ................ ......�...... I............... ......01 ✓ ✓ Vac ........ ................ ................ . . AC Frequency(Nominal................. ............... ................ ............... 59 3.60-6051?1.............. ................ H?..... Maximum Continuous Output Current 16 24 - A 208V Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A °�240V................................... ......I........ ............................... ........ ............... ........-....... ................ ...-....... GFDI Threshold 1 A . .. .,..Islanding... .............Protection....,. *"*'*-.-...-.--............-..-........................Yes ...................................................... •Utility Monitoring.. .. .. Count Configurable Thresholds INPUT Maximum DC Power @240V 4650..... .... .5900 7750 9300 11800 15500 17650 W .......... .......... ........... .... . . Maximum DC Power @208V... ......... .......:....... .....5100.... . ......- ......- ...7750..... .... :.......�........:....... ........: Transformer-less:Ungrounded Yes ....................................... .-..................................................... ........... Maximum Input Volta0e 480 Vdc ................................................ .......................-..................-...... . .... Nominal DC Input Voltage 380 400 Vdc xim In urr nt 208V _...... 9..... 13.5.... _...... _...... I...... .......�....... ... .� ..- I . ..- ......�....... ........ .......-... Ma um put C e ............... ....-.............. ... . . ... . . . Maximum Input Current @240V 8.5 10:5 . •.•135 16:5 .- •20.. 27 N Adc Max In ut Short Circuit Current 45 Adc P.... ......... ......... ......... ................I.. ......... ......... ......... ................................. . Reverse Polarity Protection Yes Ground-Fault Isolation Detection 600kn Sensitivity ............................................ ............... . . . . ........... ..- ... ... . Maximum InverterEfficiency •99 ...• 99.2 -_,% .....................n. ...........- . . ................................. ............................................................. . CEC Weighted Efficiency99...•.• %...•. ................. ........................................... ..............................................-.. . Nighttime Power Consum tion <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces R.54Et Ethernet.Zi�Bee(optional),Cellular(optional) ........................ ........... Revenue Grade,DataRANSI C12 20,,,,,,, ,,, ,,,, ,,,, ,•,,, ,,-„ ,,-„-, ......... ......... ......... ....... . ...„ ,,,,-, 9pponall2) Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFC according to T.1. M-07 ....... ....................................I..................................................................................... .... .................... ........... Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI� . .......................................... . ...... ............. .. ......................................... ........... Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWGRan�e ••,...-•, 3/4".minimum/14.6AWG 3/4',minimum/144AWG . . . . ................ . ........... DC Input Conduit Size 7#of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3/4”minimum/1-3 strings/ AWG Ran&e............... ..........14.-6 AWG.... ............... ................................................................................. . ....... ........... Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 in/mm x 185 Weight with Safety Switch 22110 1 25.1/114 1 26.2%11.9 38:8/17:6 Ib/k� ....................................... ...............................<..2.5.................. <50 d BA ..Noise ............. ....................................... ......... ....... ..-. Coolin Natural Convection Natural convection Operating Temperature Range -13•to+140/-25 to+601'1(:40%Foption)1^I %F/°C Protection Rating NEMA 3R(Inverter with Safety Swltchl Irl For other regional settings please contact SolarEdge support Irl Revenue grade inverter P/N:SE�H-USOOONNC2 (3)For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-tempemture-derating-note-na.pdf (4)-40version P/N:SEm H-USOOONNU4 rom ROHS o OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks•f So • s • System designed with All parts fit in a box for easy ` maximum versatility for any logistics arrays including staggered Drop-in features make the install process intuitive and fast _---_—_ Simple design allows system to be installed by single installer Listed to UL Standard 2703 for on the roof Grounding/Bonding and Fire Classification SnapNrack RL Universal highestis designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and the • of Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of ,-J North-South adjustability for all Mounts -- -- -- --- - - -- - - Mounts • Single mount used at all locations on array ~. • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation • Features a rock-in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments �� -` Links 1 • Simple design provides mounting platform between two to four modules _ • Clamps onto top of modules securing them in place while providing row-to-row bonding • Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules 1i • Skirt length is compatible with both portrait and landscape module orientations Guality. Innovative , Superior, SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve • installation quality and safety. . • O2019 • .. Solar . . Solutions.All • -. dad APnn OVED AS NOTED DATE: B.P. " � yc�q-2 FEE: BY: NOTIFY BUILDING: 0E PARTMENT AT 765-1602- B AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH -, FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTR!JCTION MUST BE COMPLETE F..'R C.O. ELECTRICAL ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW INSPECTION REQUIRED YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES �I (S Cor) r) �U AS REQUIRED AND CONDITIONS OF L JJ SO!ITHD D TOWN ZBA 6v- I Q C&W _ fiO► TDWNI�MING BOARD / 4,60- re HOLD T VN TRUSTEES l �'�-� r r .Y.S.DEO OLIcce n'I'b12. OCCUPANCY OR USE IS UNLAWFUL VVI H6UT CERTIFICA?' OF OCCUPANCY t • 4 - - — - — -— - -- - --- Astra v.1.696 June 15,2022 CAT COA structural Subject:Structural Certification for Proposed Residential Solar Installation. ENGINEERS Job Number:216R-055ARKL;Rev A Client:Erkan Arklan II If Address:55 Eastward Ct,Mattituck,NY,11952 L JUL 2 Attn:To Whom It May Concern BUILDING DEPT TOWM OF SOUTHOLD Afield observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun.Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: •2020 NEW YORK STATE RESIDENTIAL CODE WITH 2018 IRC/IBC/IEBC,7-16 ASCE&2018 NDS •Basic Wind Speed V=128 mph,Exposure B •Ground Snow Load=25 psf Based on this evaluation,I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally,I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summa Hardware Check Includes Uplift Check on Attachments/Fastener,Structure Check Considers Main Structure Orientation Attachment Spacing/Cantilever Configuration Max DCR Result Landscape 72/28 Staggered 56% Pass AR-01 Portrait 48/24 Staggered 72% Pass Roofing Material Pitch Structure Check Comp Shingle 19° Pass Orientation Attachment Spacing/Canti[ever Configuration Max OCR Result Landscape 72/28 Staggered 56% Pass AR-02 Portrait 48/24 Staggered 72% Pass Roofing Material Pitch Structure Check Comp Shingle 19° Pass OF NEIN K. Z,q C y0 GO lui C9 XP091365 A�OFESSIONP Paul Zacher,P.E. 1478 Stone Point Dr.Suite 190,Roseville,CA,95661 P (916)961-3960 Professional Engineer T: 916.961.3960 x101 E-mail:paul@pzse.com SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:1904OW DC,1380OW AC •ALL WORK SHALL COMPLY WITH 2020 NEW YORK STATE RESIDENTIAL CODE SOLAR MODULES •MODULES:(56)JA SOLAR:JAM60S10-340/MR WITH 2018 IRCABC/IEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS,LISTINGS SE SERVICE ENTRANCE PV-1.0 COVER SHEET •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN SE3800H-USMN,(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. SE1000OH-USSNMP MAIN PANEL PV-3.0 LAYOUT •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-0.0 ELECTRICAL TRACK ON COMP,SEE DETAIL SNR-DC-00436 SNR MOUNT •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER (([[ (� RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. Q ATTIC VENT D Ire II FLUSH ATTIC VENT OF NE !!!J 11``�� !!!! � E ^ •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER � CO �K.Zq� p�� nn MODULES,ARE CLASS A FIRE RATED. 0 PVC PIPE VENT JULO 211/ RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) 0 METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) p o 91365 BUILDING DEPT SATELLITE DISH QOFESSIONP TOWN OF SOUTH.:LD ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC For Structural Only (EE DC DISCONNECT(S) FIRE SETBACKS •10.46 AMPS MODULE SHORT CIRCUIT CURRENT. •16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX � HARDSCAPE INTERIOR EQUIPMENT —PL— PROPERTY LINE L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n ru n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER IAZIMUTH VICINITY MAP COMP COMPOSITION n egrl y nl a DC DIRECT CURRENT 00825-ME d� E EXISTING nE�vE.Nrxsv.ie ry+,eo, Machine Works ESS ENERGY STORAGE SYSTEM gP MC EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC ERKAN ARKLAN Shamrock Christmas MSP MAIN SERVICE PANEL 55 EASTWARD CT,MATTITUCK, (N) NEW NY,11952 Tree Farm NTS NOT TO SCALE OC ON CENTER TEL.(631)506.9933 PRE-FAB PRE-FABRICATED APN:1000-115-00-07-00-011-000 55.Eastward-Ci, PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: Mattituck, NY 11952... PHOTOVOLTAIC L2� RSD RAPID SHUTDOWN DEVICE 216R-055ARKL TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL V VOLTS SOHAN SINGH W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:A 6/15/2022 PAGE PV-1.0 SITE PLAN-SCALE-3132"-V-V SITE PLAN DETAIL-SCALE-1/64".1'-0" ARRAY TRUE MAG PV AREA PITCH AZIM AZIM (SOFT) ® AR-01 19- 262° 274- 488.9 AR-02 1 19° 1 82° 94° 525.1 (E)FENCE FL F GROUND FIRE SETBACKS g ACCESS POINT (18"TYP) (E)RESIDENCE o I ROOF PATHWAYS (3'TYP) (E)GATE 'l- ------------- (N)ARRAY AR-02 (N)ARRAY AR-01 sunrun 00825-ME 1S CHVtIOTTE�VE.MIGtBJIIE XY Itpt %�'111E Sfb S1051S1 FAC MSI!!.1@l ROOF PATHWAYS CUSTOMER RESIDENCE: (3'TYP) ERKAN ARKLAN 55 EASTWARD CT,MATTITUCK, NY,11952 f iNTN �TAC� T L �C J TEL.(631)5069933 APN:1000-115-00-07-00-011-000 0FNE{y� PROJECT NUMBER: (-MP GROUND K Z'40 0 216R-055ARKL ACCESS POINT F,p SE 0 DESIGNER: (415)5806920 ex3 w SOHAN SINGH v�386 �� SHEET 1 °ROF365' P� SITE PLAN For Structural Only REV:A 6/15/2022 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X4 CARPENTER TRUSSES 12'-9" 24" COMP,SEE DETAIL SNR L TRACK 0" 2'-4" 4'-0" 2'-0" STAGGERED 128 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 2-Story 2X4 CARPENTER TRUSSES 12'-9" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON6'-0" 2'-4" 4'-0" 2'-0" STAGGERED 5/16":2.5"MIN EMBEDMENT COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:1/8"=1'-0" ENGINEER OF ANY POTENTIAL ALM:262° STRUCTURAL ISSUES PITCH:19' OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. }_3'_ 44.9' - IF ARRAY(EXCLUDING SKIRT) _, IS WITHIN 12"BOUNDARY 1--0„ REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), —6'TYP— THEN ATTACHMENTS NEED TO BE ADDED AND OVERHAN REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS 13'-3" a FOLLOWS: .•ALLOWABLE ATTACHMENT SPACING INDICATED ON 8' PLANS TO BE REDUCED BY 50% ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 2T-11" 11'2 1/5TH OF ALLOWABLE ATTACHMENT SPACING 1T-10" INDICATED ON PLANS D2-AR-02-SCALE:1/8" ALM. s u n ru n PITCH::1 19° 9 00825-ME 'asHor�emsa s,m 1'1" r,x eu xeexm }-3'- 44'-9" - CUSTOMER RESIDENCE: ERKAN ARKLAN 55 EASTWARD CT,MATTITUCK, NY,11952 TEL.(631)5069933 APN:1000-115-00-07-00-011-000 6'-9 13 8 ❑ OF NE{,yY PROJECT NUMBER: —6'TYP K.ZAC,y 0 216R-055ARKL Fp DESIGNER: (415)560-6920 ex3 ❑ lu SOHAN SINGH 1,4„ xPO91 ib, Q�� SHEET 27'-11" QROFEss , LAYOUT REV:A 6/15/1022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120240 VAC SINGLE PHASE SOLAREDGE TECHNOLOGIES: SERVICE SE380OH-USMN WITH METER#: REVENUE GRADE METERING M3800 WATT INVERTER JUNCTION BOX PV MODULES PSEGLI 98302662 OR EQUIVALENT ACCOUNT#: 2a 1a JA SOLAR:JAM60S10-340/MR UTILITY NOTE:TOTAL PV BACKFEED=73A ! (16)MODULES GRID 9621053200 USED FOR INTERCONNECTIONs _ ✓. *�lj!/ OPTIMIZERS WIRED IN: SUPPLY SIDE TAP CALCULATIONS `t' (1)SERIES OF(16)OPTIMIZERS (N)1100A PV LOAD LOAD RATED DC DISCONNECT 4 CENTER WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS COMPLIANT P370 (N)LOCKABLE 3a SOLAREDGE TECHNOLOGIES: \1 EXISTING 200A BLADE TYPE MAIN BREAKER FUSED AC (N)LOCKABLE SE1000OH-USSN WITH DISCONNECT BLADE TYPE REVENUE GRADE METERING 1 AC DISCONNECT 10000 WATT INVERTER JUNCTION BOX PV MODULES 3b 2b OREQUIVALENT 1b JA SOLAR:JAM60S10-340/MR EXISTING _ (40)MODULES 225A MAIN -- OPT MIIERS WIRED IN: PANEL v (1)SERIES OF(14)OPTIMIZERSFACILITY '' 80A FUSES (1)SERIES OF(14)OPTIMIZERS LOADS PA011„o SQUARE D SQUARE D 20A BREAKER(A) LOAD RATED DC DISCONNECT (1)SERIES OF(12)OPTIMIZERS D223NRB DU323RB 60A BREAKER(B) WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,100A 3R,100A,2P COMPLIANT P370 120240VAC 120240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1a NONE (2)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 1b NONE (6)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER s u n r u n 2a 1”PVC OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 2b 1"PVC OR EQUIV. (6)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 00825-ME 3a 1"PVC OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHNITHWN-2 P oen°;oa ei" "E""'�' fNt&5.368 3033 3b 1"PVC OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHWTHWN-2 (1)8 AWG THHN/THWN-2 CUSTOMER RESIDENCE: ERKAN ARKLAN 4 1"PVC OR EQUIV. (2)4 AWG THHN/THWN-2 (1)8 AWG THHWTHWN-2 (1)8 AWG THHWTHWN-2 55 EASTWARD CT,MATTITUCK, NY,11952 MODULE CHARACTERISTICS TEL.(631)506-9933 P3OPTIMIZER CHARACTERISTICS: JA SOLAR:JAM60S70-340/MR: 340 W MINN INPUT VOLTAGE: 8 VDC APN:1000-115-00A7-00-011-000 OPEN CIRCUIT VOLTAGE: 41.55 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX POWER VOLTAGE: 34.73 V MAX INPUT ISC: 11 ADC 216R-055ARKL SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)50D-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM CHARACTERISTICS-INVERTER 2 SOHAN SINOH SYSTEM SIZE: 5440 W SYSTEM SIZE: 13600 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 16V SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 6/15/2022 SYSTEM OPERATING CURRENT: 14.32 A SYSTEM OPERATING CURRENT: 34 A SYSTEM SHORT CIRCUIT CURRENT: 15A SYSTEM SHORT CIRCUIT CURRENT: 45A PAGE PV-4.0 INVERTER 7 NOTES AND SPECIFICATIONS: ARN I N G I WARNING •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE PHOTOVOLTAIC • 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM IF REQUESTED BY THE LOCAL AHJ. COMBINER PANEL • 480 • •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD DO NOT ADD LOADS 15 '• •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAYBE ENERGIZED IN RATEDMAX • • METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION LABEL LOCATION: •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PHOTOVOLTAIC AC COMBINER(IF • '• ••DC-TO-OC • t IS •• INVOLVED. APPLICABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY LABEL LOCATION: PER CODE(S):NEC 2017:705.12(B)(2x3xc) SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),ACIDC DISCONNECT(S), LABEL LOCATION: •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). PER CODE(S):NEC 2017:690.13(B) PER CODE(S):CEC 2019:690.53,NEC 2017:690.53 INVERTER RN IIyG DUArUTIUTY PHOTOVOLTAIC DC DISCONNECT POWHt SOURCE OUTPUT CONNECTION SOU • a6o •DO NOT RELOCATE THIS AND as • OVERCURRENT DEVICE MAX D OUTPUT CURRENT OF LABEL LOCATION: LABEL LOCATION: CONTROLLER••DC-TO-DC C• • 15 •• ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. LABEL LOCATION: PER CODE($):NEC 2017: PER CODE(S):NEC 2017:705.12(BX3) INVERTER(S),DC DISCONNECT(S). 705.12(B)(2)(3)(b) PER CODE(S):NEC 2017:690.53,CEC 2019:690.53 - NOTICE- COMBINERPV SYSTEM DO NOT ADD LOADS TO THIS PANEL FOR SOLAR PV SYSTEM LABEL LOCATION: INSTALLED WITHIN 3.OF RAPID SHUT DOWN 2SWIT6HH PER 1CODE(S)6NEC 2013:690.56(C)(3),IFC BUILDING SUPPLIED BY UTILITY GRID AND PHOTOVOLTAIC s u n ru n 4. _ t SYSTEM SOLAR PV SYSTEM EQUIPPED 00925-ME - - • • • 15 GVRLOiTE AVE.NI[,1f3/LlE NY 11•l1 -� - WITH RAPID SHUTDOWN CUSTOMER RESIDENCE: LABEL LOCATION: ERKAN ARKLAN INTERIOR AND EXTERIOR DC CONDUIT EVERY IF' 55 EASTWARD CT,MATTITUCK, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, NY,11952 ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. 3" TURN RAPID SHUTDOWN PER CODE(S):NEC 2017:690.31(G)(3),690.31(G)(4), IFC 2012:605.11.1.4 SWITCH TO THE"OFF' , ,..,Cs•'CLL'� TEL.(631)5069933 POSITION TO SHUT DOWN APN:1000-115-00-07-00-011-000 PV SYSTEM AND REDUCE PROJECT NUMBER: SHOCK HAZARD IN THE rlSTEM 216R-055ARKL PHOTOVOLTAIC • • ARRAY. DISCONNECT •• -• - DESIGNER: (4 15)560-6920 ex3 NOMINALOPERATING • •• SOHAN SINGH LABEL LOCATION'. LABEL LOCATION: LAPOINT OF INTERCONNECTION SHEET LABEL LOCATION: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF EL O MORE THAT 1 M(3 FT)FROM THE SERVICE (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) SIGNAGE IRTERCONNECTION. ON OR PER CODE(S):NEC 2017:690.54 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 6/15/2022 PER CODE(S):NEC 2017:690.56(C)(1 xe) PAGE PV-5.0 Harvest the Sunshine milli hai now � �:.�� '' ►� 340VV MBB Half-Cell Module JAM60S 10 320-340/M R Mono (intr Series . • Assembled with multimbusbar PERC cells,the half-cell configuration of the modules offers the advantages of • power output, loading.shading effect on the energy generation,lower risk of hot spot,as well as enhanced tolerance for mechanical Higher output power Lower LCOE (A Less shading and lower resistive loss Better mechanical loading tolerance Superior Warranty) Comprehensive Certificates • 12-year product warranty IEC 61215,IEC 61730, UL 61215,UL 61730 • 25-year linear power output warranty ISO 9001:2015 Quality management systems 100% ISO 14001:2015 Environmental management systems • OHSAS 18001:2007 Occupational health and safety manage- ment systems • IEC TS 62941:2016 Terrestrial photovoltaic(PV)modules— bit Guidelines for increased confidence in PV module design ■ JA Linear Power Warranty ■ Industry Wananty JASOLAR -. JA Solar reserves the right of final - a JASOLAR JAM60S10 320-340/MRS --_--_-_--_-MECHANICAL DIAGRAMS._ ._.--.-------_--___--T-------T___-___._-___.-SP-ECIFICATIONS___�----__T--,----_.-_-• sssu 35:1 Cell Mono I Weight 18.7kgt3% 11111111111111 Hill Dimensions 1689t2mmx996t2mmx35d:1mm Enlarge view of mounting hole(0:1) Cable Cross Section Size 4mm' (12AWG), Grounding holes 10 places No.of cells 120(6x20) iiiiiiiiiiiiiiiiiiiiiipillillillI HE 1111111111 O O O - un., Junction Box IP68,3 diodes Nbunlirg lwlea a.n Connector QC4.10 (1000V) 8placea QC 4.10-35 (1500V) Label Cable Length Portrait:300mm(+)/400mm(-); Draining roles (Including Connector) Landscape:1 000mm(+)/l 000mm(-): 8 places Packaging Configuration 30 Per Pallet Remark-customized frame color and cable length available upon request ELECTRICAL PARAMETERS AT STC -- -- - ---- -- - -- - - ---- - - - -- _ --- - - - - __ _- - -- -------- JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 TYPE -320/MR -325/MR -330/MR -335/MR -340/MR Rated Maximum Power(Pmax)[W] 320 325 330 335 340 Open Circuit Voltage(Voc)[V] 40.60 40.87 41.08 41.32 41.55 Maximum Power VoRage(Vmp)[V] 33.73 33.97 . 34.24 34.48 34.73 Short Circuit Current Isc A 10.16 10.23 10.30 10.38 10.46 Maximum Power Current(Imp)[A] 9.49 9.57 9.64 9.72 9.79 Module Efficiency[%] 19.0 19.3 19.6 19.9 20.2 Power Tolerance 0-+5W Temperature Coefficient of Isc(a_Isc) +0.044%/°C Temperature Coefficient of Voc([i_Voc) - -0.272%/*C Temperature Coefficient of Pmax(y_Pmp) -0.350%/°C STC Irradiance 1000W/m, cell temperature 25°C,AM1.5G Remark:Electrical data in this catalog do not refer to a single module and they are not part of the offerThey only serve for comparison among different module types. ELECTRICAL PARAMETERS AT NOCT OPERATING CONDITIONS TYPE JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 Maximum System Voltage 1000W1500V DC(UL) .320/MR -3251MR _ -330/MR 335/MR -340/MR . Rated Max Power(Pmax)[W] 241 245 249 253 257 Operating Temperature -40°C-+85 C Open Circuit Voltage(Voc)]V] 38.05 38.26 38.46 38.68 38.90 Maximum Series Fuse 20A Max Power Voltage(Vmp)[V] 31.58 31.80 32.02 32.21 32.40 Maximum Static Load,Front 5400Pa(112 Ib/ft') Short Circuit Current(Isc)[A] 8.07 8.14 8.21 8.28 8.35 Maximum Static L_oad,Back 2400Pa(50 Ib/ft') Max Powe_rCurrent(Imp)[A] 7.63 7.70 7.78 7.85 7.93 NOCT 45±2°C ; NOCT Irradiance 800W/m',ambient temperature 20°C Fire Performance Type 1 wind speed 1m/s,AM1.5G CHARACTERISTICS Current-Vo@age Curve JAM60S10-335/MR Power-Voltage Curve JAM60S10-335/MR Current-Voltage Curve JAM60S10-335/MR 350 10 -1000W/m' -1000W/m' 10 10°�-- 300 -800yV1m' -251c_ - -600w/m' 8 -auv;/mom _-- 250 -- -- 8 --40'C _-___N\\ _ -�OOW/m? - _ - 200 - C -- 6 -70°C- 6 -b-OOW/m, 30 150 U 4 -400W/m' -- - - 0_ U 4 100 - - --- -- - -- - 2 - 50 - - --- - 2 --- - - 0 0 10 20 30 40 00 10 20 30 40 0 0 10 21 30 40 VoltageM Voltage(V) Voltage(V) ModulesPremium Cells, Premium 0' so -ar = • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE10000H-US/SE1140OH-US - -- - -- _ solar,[' �.rHllworel. A solar=.. F(�lDT� .,, < - rash -I, •r . - 1..,.—__1- --•.+.-.-.-..-._....._,,,.,,,,ems` f� __'-'.—.-T-__—_- _- i 7-__ t � - I 1� O Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12. UL1741 SA certified,for CPUC Rule 21 grid compliance 1 Extremely small � II High reliability without any electrolytic capacitors I - Built-in module-level monitoring 11111 '�D Outdoor and indoor installation wave - Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) a I I L �- - -— --------- - -—--- -- -- --- - - - --- ------- - -� www.solaredge.us =@@ single Phase Inverterso-I a r --� with HD=Wave-Te-chn�ologyfor-North--America -- - -- --�- ---- - SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE10000H-US/SE1140OH-US SE3000H-US SE380OH-US SE5000H-US SE6000H US SE7600H US SE10000H US SE31400H US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 00 7600 10000 11400 VA .............................................. ................ 3300,E 208V. 50 .a-208V, Max.AC Power Output 3000 3800 @ 240V 50006000 @ 240V 7600 10000 11400 VA .............................................. ................ 3300,E 208V. 5.000.p.2q8y. ................ ................. ................. ........... AC Output Voltage Min.-Nom.-Max. Vac (183,:208 229)........................... . ............... ................ ................ ................. ................ ................. ................. ........... AC Output Voltage Min.-Nom.-Max. J / Vac (211,-240_-264)........................... ................ ................ ................ ................. ................ ................. ................. ........... AC Frequency(Nominal) 59.3-60-60.501 Hz Maximum Continuous0utputCurrent 208V 16 24 A ......:...........:........................... ................ ................ ................ ................. ................ ................. ................. ........... Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A ..@ 240V.................................... ................ ................ ................ ................. ................ ................. ................. ........... GFDI Threshold1 A ..................................... ........................................................... .......................................................... Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4.650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 7750 .............................................. ................ ................ ................ .......... ................ ................. ................. ........... Transformer-less,Ungrounded............ ..........................................................Yes........................................................... ........... ................ Maximum In ut Volta a 480 Vdc P... .................... ........................... .................................................... . Nominal DC Input Voltage 380 400 Vdc ............ ... ................ ... .......... . ................. ................ ................. ................. ........... Maximum Input Current 208V............ . ..............I...... g:......1.......:........1......13:5......I...... ..........I........ ........I...... ..:........ Maximum Input Current @240V 8.5 10.5 13:5 16.5 20 27 30S Adc .. .......T.. . ... . ....... Max..In...put..Short. .Circuit. ....Current.... .......... 45 Adc . .. ... . . . ... ......................................................................................................................... ........... Reverse:Polarity Protection ..........................................................Yes Ground-Fault Isolation Detection 600ksSensitivity .............................................. ................ . . . . ..................... ........... Maximum Invert.....er Efficiency 99 99.2 ...................... ...... ........................................................................................................ ........... CEC Weighted Efficiency.................. ................. ...............99 �. .. Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) .......................... .. ............................... ........... Revenue Grade Data,,AN51 C12,20..... .. pt, ...............Ooval!.......................................... Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 .....E5*4".................................... Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4':minimum/14:6 AWG 3/4"minimum/14-4 AWG DC Input Conduit Size/#of Strings/ ........ . . . .i nimnn.um� 3/4"minimum/1-2 strings/14-6 AWG 3/4"mium/1-3 strings/ AWG Range,,,,,,,,,,,,, 14-6 AWG ................... ..................................................................................... ............. ..................... ........... Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 in/mm .............................................. ................................. ................ .................................. ..............x 185............... ........... Weight with Safety Switch 22/1 0 1 25:1/,11:4..1.. .......26.2/11:9 38.8/17.6 17:6............ .Ib/.kg... Noise <25 <50 dBA . ..... . ...... ................................... Cooling Natural Convection Naturalconvection Operatin�TemperatureRanpe ............ ..............I.....................13 to+140/-25 to+60131(:40'F/:40Coption)1"1 'F /°C . Protection ... NEMA 311(Inverter with Safety Switch) pl For other regional settings please contact SolarEdge support 121 Revenuegrade inverter P/N:SE3 H-USOOONNC2 131 For power de-rating information refer to:https.//www.solamdge.mm/sites/default/files/se-temperature-derating-note-na.pdf 141 40version P/N:SEI H-USOOONNU4 r Off RoHS 0 OPTIMIZED BY SOLAREDGE • r Aft System designed with � � All parts fit in a box for easy ` maximum versatility for any logistics arrays including staggered Drop-in features make the install process intuitive and fast Simple design allows system to be installed by single installer Listed to UL Standard 2703 for on the roof Grounding/Bonding and Fire Classification SnapNrack RL Universal highestis designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and the • . of Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of <� North-South adjustability for all Mounts Mounts j • Single mount used at all locations on array ,'- • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation • Features a rock-in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments W2 Links • Simple design provides mounting platform between two to four modules • Clamps onto top of modules securing them in place while providing 1411, row-to-row bonding �, • Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules it 4 • Skirt length is compatible with both portrait and landscape �`' module orientations Quality. Innovative , Superior. SnapNrack Solar Mounting . and improve . quality and safety. . • www.snapnrack.com . . 2019 by SnapNrack Solar Mounting Solutions.All rights reserved DESCRIPTION: , DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins -- ------------------ -- - --- - - - -- --- -- -- � - - --REVISION:-`- --- PART NUMBER(S): 595 MARKET STREET,291H ROOR•SAN FRANCISCO,CA 94105 USA PHONE(415)560-6900•FAX(415)580-6902 242-02155 THE INFORMATION IN THIS DRAWINGCONFIDENTW-AND PROPNIETARY.ANY REPRODUCTION,DISCLOSURE,OR USETHEPEOF IS PROM&TED WITHOUTTHE WRITTEN CONS@!T OF SUNRUN SOUTH LLC. 10 5 0 4 3 7 8 1 2 o 6 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK, RL UNIVERSAL, LEVELER, MILL 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL 4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK 5 1 SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 1 SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS 8 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1IN, SS 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1 BOLT, FLANGE, SERRATED, 3/8IN-16 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 623 UP, 674 DOWN, 505 SIDE ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.73 DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins REVISION:" PART NUMBER(S): 595 MARKET STREET,29TH FLOOR SAN FRANCISCO,CA 94105 USA PHONE(415)580-6900•FAX(415)580-6902 242-02155 THE INFORMATIONINTHISDRAWINGS TO REONTLILMIDPROPRIETARY.ANY REPRODUCTION,MIS ESUREORUSETHEREOFIS PROHI&TED WITHOUTTHE WRITTEN CONSENT OF SUNRUN SOUTH LLG —1.50 T7 3.41 I F 1.50 s; 2.35-� 1.50 1.55 .66 �2.00 1.24 1.00 SLOT sy 2.63 1.50--- ALL DIMENSIONS IN INCHES