Loading...
HomeMy WebLinkAbout27016-z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-27853 Date: 08/03/01 THIS CERTIFIES that the building ADDITION Location of Property: 2940 PINE TREE RD CUTCHOGUE (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 104 Block 2 Lot 18 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated OCTOBER 4, 2000 pursuant to which Building Permit No. 27016-Z dated JANUARY 17, 2001 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITION TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to ROBIN SWEENY (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. N 564520 07/18/01 PLUMBERS CERTIFICATION DATED N/A tho ized Signature Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 27016 Z Date JANUARY 17, 2001 Permission is hereby granted to: ROBIN SWEENY 1895 STERLING RD CUTCHOGUE,NY 11935 for ADDITION TO EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. at premises located at 2940 PINE TREE RD CUTCHOGUE County Tax Map No. 473889 Section 104 Block 0002 Lot No. 018 pursuant to application dated OCTOBER 4, 2000 and approved by the Building Inspector. Fee $ 75 . 00 Authorized Signature ORIGINAL Rev. 2/19/98 f Form No. 6 ~ TOWN OF SOUTHOLDG`V1 BUILDING DEPARTMENT L __ TOWN HALL 765-1.802 APPLICATION FOR.CERTIFICATE OF OCCUPANCY A. This. application must be filled in by typewriter OR ink and submitted 'to the building inspector with- the following: for new building or new. use: 1. Final survey of ..property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2.. Final Approval from Health Dept. of water supply, and sewerage-disposal(S-9' form) . 3. Approval of electrical installation from Board of Fire Underwriters. . 4. Sworn statement from plumber certifying that the solder used in system contains less- than 2/10 ,of 1% lead. 5. Commercial building, industrial building, multiple. residences and similar buildin; and -installations, a certificate of Code Comp.lianoe from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9; 1957) non-conforming uses, or buildings -an( "pre-existing" land uses: I. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a.consent to inspect signed by the applicant. If a Certificate of- Occgpancy is denied, .the Building Inspector.shall state the reasons therefor in writiug'to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.003 Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.90. Businesses $50.00. - . . 2. Certificate of Occupancy on Pre-•existing Buildine - $100.00 3. Copy of Certificate of Occupancy - .25ip 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date ... .. . . . ... .... . . .. . ... . . . .... . Few Construction. . ..... . ' . Old Or Pre-existin Bu ding. . .. .✓. . . . . ... . s .. . l .. Location of Property../. . . .. .. .. .. . . �.�Y.... . . . . .. . .. House No. Zet Hamlet Onwer or. Owners of Property.. . .. . .t'. !' ..:'�.w..'. y. .. 4. . . . . . . . . . . . . .. . . . . .. . . . . . . . . . County Tax Map No 1000, Section. AfW. . . . . .Biock� . . . . . . . . . . . .Lot. . . 4W . .4 . . . . . . . .. . Subdivision. . . ./. . . .. . . . . . .. .Filed Map. . . . . . . . . . . .Lot. . . . . . . . . .. . . . . . . . . . Permit NO. . .. .. . . .. . . . . . . .Date Of Permit. . . .�:�. R!.. .Applicant. .4:�a,r..!i!.�"'�. . .�.�u Health Dept. Approval. .. . . . . ... . . . . . .. . . . . . .. . .Underwriters Approval. . . . . . . . . . ,. . . . . . .. ... . . Planning Board Approval. .*. . . .. Request for: Temporary Certificate. .. . . . . . . . . Final Certicate. . .-s!. . . . . iee Submited: $... . 5-6-D. . .. . . . .. .. . . . . . /1 ,3 THE NEW YORK BOARD OF FIRE UNDERWRITERS PAGE 1 1000121 BUREAU OF ELECTRICITY 4OF,ULTON STREET, NEW YORK, NY-10038 Application No. on file �'' �'F /-:� N 564520 THIS CERTIFIES THAT only the electrical equipment as described below and introduced by the applicant named on the above application number is in the premises of ROBIN SWEENY, PINE TREE ROAD, CUTCHOGUE, NY in the following location; ❑ Basement ® 1st Fl. ❑ 2nd FL OUT Section Block Lot was examined on JULY 05,2001 and found to be in compliance with the National Electrical Code., FIXTURE RECEPTACLES SWITCHES FIXTURES RANGES COOKING DECKS OVENS DISH WASHERS EXHAUST FANS OUTLETS INCANDESCENJ FLUORESCENT OTHER AMT. K.W. AMT. K.W. AMT. K.W. AMT. K.W. AMT. H.P. 4 7 3 4 DRYERS FURNACE MOTORS FUTURE APPLIANCE FEEDERS SPECIAL REC'PT. TIME CLOCKS BELL UNIT HEATERS MULTI-OUTLET DIMMERS AMT. K.W. OIL H.P. GAS N.P. AMT. NO. A.W.G. AMT. AMP. AMT. AMPS. TRANS. AMT. N.P. SYSTEMS AMT. WATTS NO.OF FEET SERVICE DISCONNECT _ NO.OF S E R V I C . E METER NO.Of CC GOND. A.W.G. A.W.G. A.1, G. AMT. AMP. TYPE EGTUIP. 1 O 2W 1 SW 3•SW 3 0 4W PER 0 Of CC.COND. NO.OF HI-LEG OF HI-LEG NO.OF NEUTRALS OF NEUTRAL OTHER APPARATUS: G.F.C.Ir-2 PAUL R. BURNS LTC.#3$97-1 cwt PO BOX 1061 SOUTHOLD, NY, 11971-0932 GENERAL MANAGER 11 -- Per — This certificate must not be altered in any manner;return to the office of the Board If incorrect.Inspectors may be Identified by their credentials. COPY FOR BUILDING DEPARTMENT. THIS COPY OF CERTIFICATE MUST NOT BE ALTERED IN ANY MANNER. O��gUf FO(,�c O c� Gyp C* Town Hall,53095 Main Road Fax(631)765-1823 P.O.Box 1179 ifi O�� Telephone(631)765-1802 Southold,New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD July 24, 2001 Dan West 665 Goose Creek Lane Southold, NY 11971 RE: Sweeny, 2940 Pine Tree Rd (aka 1895 Sterling Rd), Cutchogue TO WHOM THIS MAY CONCERN: We are unable to complete your Certificate of Occupancy because of the following reasons: xx An application for Certificate of Occupancy is not on file. (Enclosed) No Underwriters Certificate on file. xx The check is (not in file)$25.00 No Health Department Approval on file. No final inspection has been made. No Plumber Solder Certificate on file. (All permits involving plumbing being issued after April 1, 1984) • BUILDING PERMIT # 27016 -Z Please contact our office on this matter. Thank you for cooperation. SOUTHOLD TOWN BUILDING DEPT. M-1802 BUILDING DEPT. INSPECTION [ j FOUNDATION IST [ ] ROUGH PLBG. [ j FOUNDATION 2ND [ ] INSULATION [✓]FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY i REMARKS: ,DATE �1-1-3101INSPECTOR BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLB6. [ ] FOUNDATION 2ND [ ] INS ON [ ] FRAMING [ FINAL [ ] FIREPLACE & CHIMNEY REMARKS: �Q DATE INSPECTOR a- 7oi M-1802 BUILDING DE". INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN CATION [ ] FRAMING [ FINAL [ ] FIREPLACE & CHIMNEY REMARKS:((Drr ___�✓�_ ol K DATE 7� INSPECTOR X)o BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND ( ] 1 CATION 1 FRAMING [ FINAL [ ] FIREPLACE & CHIMNEY REMARKS: ,DATE INSPECTOR ��L suiLuiNa DE". iNSPECTION ZFOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ J FIREPLACE & CHIMNEY REMARKS: ILL 4 )i ,DATE 10-7 INSPECTOR . M-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] RO H PLBG. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPL E & CHIMNEY REMARKS .� ,DATE INSPECT FIELD INSPECTION REPORT D_A E __====_ COrIl�iENTS = FOUNDATION ( 1ST) n H __ II I_ FOUNDATION (2ND) n � ------------------------- --- ---------------- ------------ ------------ -------------- -------- ' f t II II -_- ROUGH FRAME & n- JI PLUMBING �� I INSULATION PER N. Y. n �i STATE ENERGY CODE i ii II I� IIf FINAL 000 aaas=aa=xsa=xxxxx=xxxxxx=_ ��xx _ _ - xaaaa�rC��-_e�ssa= 0 ADDITIONAL COMMENTS: axaaxxccea=xxaxaa===xx=x=====x=x==x�==xx=xax�xxxxxxx—_---x _ tvy H O x � r r-1 ro H a � BOARD OF HEALTH . . . . . .. . . . . . . . . FORM NO. I 3 SETS OF PLANS . . . . . .. . . . . . . . . TOWN OF SOUTHOLD SURVEY BUILDING DEPARTMENT CHECK . . . . . . . .. . . . . . . . . . . . . . . . . ?G:iTHC3LD N TOWN HALL SEPTIC FORM . . . . . . . . . ... . . . . . . . SOUTHOLD, N.Y. 11971 DEC . . . ...... .. ....... ... . S TEL: 765-1802 TRUSTEE . . . ........ ....... . . . . NOTIFY.\ CALL .G,cat7.�c%ff Examined......0. �..�.., 20 1. MAIL TO: . 5.9.E/j%. . . . . . . . Approved...... .!�?:..,2C?Q 1. Permit No. ..:....!t .. .......... ........... Disapproved a/c .................................. ............................... ...................................................... .. .... ............. (Building Inspector) APPLICATION FOR BUILDING PERMIT Date. . . . . . . . ., 2G INSTRUCTIONS a. This application must be completely filled in by typewriter or in ink and submitted to the Building Inspector wi 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this application. c. The work covered by this application may not be cammenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such permit shall be kept on the premises available for inspection throughout the work. 4. No building shall be occupied or used in whole or in part for any purpose whatever until a Certificate of Occupancy shall have been granted by the Building Inspector. APPLICATION IS HEREBY MATE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. .... ��*W (Signature of applicant, or name, if a corporation) (Mailing address of applicant) 9 7/ State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder ............... .c :............... .................................................................. Name of owner of premises ......�:ala i!.'...!.:':iJ ..^�c.!'e r C1.7.............................................. (as on the tax roll or latest deed) �.J If applicant a corporation, signature of duly authorized officer. ..... t ............................. (Nene and title ofZr� te officer) Builders License No. r?,�.7.,Ze.: .... Plumbers License No. ......................... Electricians License No. ..................... Other Trade's License No. .................... 1. Location of land on which proposed work will be done.............................................................. i� e House Number Stree County TaX Map No. 1000 Section .... ,1...... Block ..... .......... Lot ... ......... Subdivision ...................................... Filed Map No. ............... Lot ............... (Name) 2. State existing use and occupancy of premises and int use and occupancy of proposed construction: a. Existing use and occupancy .......4vw. n a... ... / :.................................... b. Intended use and occupancy ...................:........... ...... .................. ,:� ri, t 3. Nature of work (check which applicable): New Building .......... Addition ... ✓ .. Alteration Repair ............ Removal ............ Demolition ............ Other Work ................................. (Description) 4. Estimated Cost ... ��s.�.'�......... fee (to be paid on filing this application)••••• 5. If dwelling, number of dwelling habits ............ Number of dwelling units on each floor ................ Ifgarage, number of cars ...................................... 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use...................... 7. Dimensions of existing structures, if any: Front.... ��.'P ......- hear •-,-yr � ,,, Depth --Z-........ .� TZ� fc�2ve�) .... Height .....lir................. Number of Stories ...�.L•.-,•,,,,,�� . �.. d Dimensions of same structure with alterations or additions: Front ........1 :e Rear —f Depth ...:�'........... Height .... 'e::.:....... Number of Stories ... 11 r i 8. Dimensions of entire new construction: Front .../!�.......... Rear .....Z....... Depth .�L Height ......lY..............: Number of Stories ..... .............. 9. Size of lot: Front ....Se n...:s v,Lar .................... Depth .................... 10. Date of Purchase ..................... Name of Former Owner ........................................ If. Zone or use district in which premises are situated .............................................................. 12. Does proposed construction violate any zoning law, ordinance or regulation: ........................ 13. Will lot be regraded ... �� ......... Will excess fill be removed from premises: AYES 14. Names of Owner of premises 70 !:r. wee ... Address !!'3l:� Phone No. Name of Architect ..4:5, ..=�:: •.e •f- -• ....... Address ..:�/.�. 1 .... Phone No. ............. Name of Contractor ....G��'�=` •-• �. Address�.� .-. .o-v,::e•C •..Phone No.71v '�!� 15. Is this property within 300 feet of a tidal wetland? * YES ..........�,,,,,,,, *IF YES, SUEM11D TOWN IMMMS PEFWT MAY BE RE VMM. t PLOT DIAGRAM Locate clearly and distinctly all buildings, whether existing or proposed, and indicate all set-back dinensioris from property lines. Give street and block number or description according to deed, and show street names and indicate whether interior or corner lot. �'nc S F SU IT Or NU YORK, C SS OOUNIT OF •ctF's4. ......... le j - . ........................being duly sworn, deposes and says that Fie is the applicant Ole victual signing contract) a1 .........L_.®`?t.................................... . (Contractor, agent, corporate officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief.; and that the work will be perfo tlhe manner set forth in the application filed therewith. Sworn to before me this ..... ^.........day of 6 �oo .. Notary Public .... ....... .. ... ... ....���'C�i�!-........ ROBERT I.SCOTT, (Signature of Applicant) Notary Public,State b ew York Qualified in Su County No.01$C4 Term Expires May 31, BUILDING PERMIT REVIEW CHECK LIST DATE REVIEWED: APPLICANT NAME: DATE SUBMITTED: /O/ �/Od SCTM# --- DISTRICT: 1,000 SECTION: /Of BLOCK: Z LOT:—/,;- PROJECT OT: /,;-PROJECT LOCATION STREET: ?fi 90 -� �o a� CITY: �47�I�oSUBDIV. NAME: ARCHITECT/ENGINEER: FAST TRACK: YES OR NO SINGLE & SEPARATE CERTIFICATION-REQUIRED: YES OR(NONOTES: ZONING: PERMIT?409IR80. ATE AMOUNT:_$ �4— .00 ZONING DISTRICT: AC CONFORMING: YESI CNO>EQUIRED LOT SIZE: ?o K_SOFT. WHERE ACTUAL LOT SIZE FROM TAX CARD 1 3 9¢ ACTUAL LOT SIZE: /7IQ- SQFT. REQUIREDREQUIRED 2-0 QUIRED hF FRONT 'PROPOSED:_ ' SIDE YD: /O '/ _' PROPOSED: '/Y' REAR: �'PPROPOSED:16' LOT COVERAGE: ALLOWED: EXISTING: /-eCO sf�% NEW: 6Ge sf, % TOTAL:/-Z sf�% CORNER? YES R NO WAT ER FRONT? YES o N DESCRIPTION: 1 11 LOTS 40,000SF --100-24. Lot recognition. (CREATED before June 30, 1983), UNDERSIZED LOTS FROM JAN.1997 100-25. Merger. (A nonconforming at any time after July 1, 1983.) PROJECT DESCRIPTION:6 D:j )ALT,ACC OR N/D: AGENCY PERMITS REQUIRED FOR REVIEW DED TOWN SPETIC PERMIT: ES r NO Z-n 4SR SUFFOLK COUNTY HEALTH DEPT: YES or NO, (BED #): DTE: / / PERMIT#:R10- NEW YORK STATE DEC: PRE-DEC 9/1/75 YES o SOUTHOLD TOWN TRUSTEES: YES or TOWN ZONING BOARD APPROVAL: YES or TOWN PLAN. BOARD APPROVAL: YES or O FLOOD COMPLIANCE ZONE: PRE-FIRM 3/18/80 P L #:_ FLOOD ZONE: ( - ec, $ NYS ENERGY: ES R NO K — EGRESS: VENT: LIGHT: NOTES: dog FEE STRUCTURE: FOUNDATION: SF FIRST FLOOR 366 SF SECOND FLR SF INIT OTHER TOTAL TOTAL: 366 -SF FEE FEE FEE TOT( 304 SF)- ( SF)= SF X $ _$ +$_,76 ---+$ _$ ,N►wvClcu rvn.- /� O e-;%m-/ �C/.UiCy� _Juic c 1r �r / / r n LOCATED AT GcircS/ofyc�er, Tow1/ GK' tS�Tyo� �, S[J�f=G�l Co•,�C/� �� � F\• �� . ' `''• LOT 4 MAP OF �L7S5Ac/ F4,t2M.5 �" /GED. /�Ar2Cy 06. /' 306 i/79 SCALE 1 ¢p' / C� O; 4.;.,: �r O S ° LAND X 20 ,loo u W 6✓oclp X/2 2 0 =i56 p 4 r trr�s Fv• ` \� ° �� 37. 6, X?6 Z 1-�' �� 29 G O le v% VIS Gee•. 2 43 (V 4.J Q 2 / t; v=sr . / x l s ✓ v f 9 T /S.Z 9 Alb �•O6t.0• 1 N.7 3�r CI w i Qa s��w _ 9 ..�. Tp G _ SaU Tti F L y ` UNAUTHORIZED AL TION OR AOOITI OI 10 un5 aJR.,! it VIOIATICN OF SECTION 7209 OF IH N'W YUlcd STATE .(Un lW.S` TF RL /tib co,1-,i OF IVIS S,iit. Y ;,i:.T 1101 DFARI G TN_ ... a aUa. • :. EMYRU354-0 SUA -I..-.LL hOf Bc CONSIU TO OL w WALIO Ii:U. GDpY. .D CU"JL N1ELS 1:(Ul ..i-G hcli Ci! Sil;ll 7 Y S' ONLY W II:E r-hoU,. TUR .r,U1cU, :.JW Utl i,;.; ,U Ib / 0190 — ���- 1 COMPA0. CU_':J.••.icfiTh. LENUIIa I..,' •w_it;y D TO THc ksSiOa.�i UI II-f LE. _.:.0 iilSTl TUTION. (;u WlNiL.S ..I(_ 6U. E TO��.'4r1fYti/r�Lc(� TU OWhL11111(INAL IIWIIIUUJaS SURVEYED 4c.1G d, 1901 f BY WILLIAM R. SIMMONS III 70 WEST MAIN STREET EAST ISLIP. L.I., N.Y. FILE NO. /9230 PAGE GRID 1M7a -rsrs:�Te.. mr^'�^s syn M G 1 ,, x 1 ------------- BUILDING CONSTRUCTION NOTES: NEW AIDMINt RMUMM BUNR00M •�Ym W :iM _ ®�� � L M°mMLrliawdRiYlamf04dommy'wM ErNwY°hBYr>ldWIq OOYmlhQobdwNYMngdL�rbY d*emrb,rwAodwogd nmrbdnboditb'Nd li ;,^ e_.t DaIpCtMrelm fMBDrOmrDgh x. AA.S Av°lAb°d��mEbEr�r�°e+ma+°• eE rdrlwdawdrELa.ba.y.E�wworwme.yrEeb O.A.It DWW FWWN* M LA.76D.Owl r..Mlt mmolmt d"-tephd y dr BhbYHrB Depmlmml IL IeE°IW AdEobdPgiLl{rn9oibbY°°dx . JII C. AO wbbwe,doamft apenirp,elm iBMam6ddwremretdppeA 3. Ihormeor uhob dmrmmmabSoa,6abNrBbrwtLml ?toWembdmbMebAMpbB mma All ' mto SUB15yumd AREA DROM "U" MCKMMAL RA7'INIi R®dARBB b°dlbalywh°dadmeMmbdymRdtrhome. : damdWorbrtr 4, BmSimmorismrerpohribtrteryotvhlydorEl lbrom Amom momarmrhMryAdFIL ... .,..:. ..:.: _ ......�.._ _ . `.` I oc Mdomh. Inotwrknot s®b trr7ob+LrwW°mw+YEmVd rp?�A Bldrla WaBr 272 .067 t27 R-I5 IHeuaT dN . . , - , •;., OLdhB•Door 40 .Sf. -6 ANDERSEN MP OR EQUAL Widows 123 .32 -22 ARDERMN HP OR EQUAL 6. Theeaplaer drSbe 00 btrtroomrlddrw dmnbg a*. Rhdrgumbe MN I kr _ ham� w m.Mbiladwodmmml4a �a� 1®mhkClx ci � ?IBho?.ViE0KYa4A`liraCaeA� fardwiledps liamL�yre4°ergMatyeemoe0 V I _ ... cefta I a - ... amatmlba Ntr1ad 111whbC°dA 7. Blmhir bbamh®btr Now Yodc No Cook ll.B'A Cellfos(CaIMAwu 346 .OSS +S RdO INSULATION z b ?bmbieBbbamm®bmeCamrydLAmmRm86 Depmmmlmghhemm,dNYB Oodw SkylWo - - I 9. AOhP°d°d°Lr9ob�h86.bdW1°m°mlboe whhNYB OodedmOcwrr 9rd6mdooR O O rt A Flow 304 .053 -2 R-19 INSULATIONI— .I 10. AN dockl m dmwbmbW egmPmtIs lobeelnmedroFHMAdNW Oodem Mmdmim WaW V 1 u. 1idW0nd?mlakoelLbbBhy Q li I Slab lhoukdon By moopft eoaamotbow om Ona /bmmt now o rmSo *aHLbftotbml Had DmmesdDriw.d LiJ dwkI Ierdabm4Wn,mbdena.r3 dad Me wd yprb HddkofBat BdDMlgt Dmip,d Q z 7MALo +2 bmedm/hmriAhotm°wdaaWYtrwrvlsEadmdvadrpEaJmt I .. ._ . . 12. ABdarfsoapbrmddwrbrm pm*oiedmdy rbdKdoopyd*bw. N°ploamberepmAa adnmhrhroW _ .. I wmbetwdhmp O01Miu. C) . — — — — — I N07TML W ... Ra1WoBBdvelape SymlmabemmtEmphamam478132 13. Ownre/Ornheobr®rtwdlymydoe gwcdc hremt bramaamhhabmMAN floodimmmerepiI ShL � (n HVAC Bghipm HVAC SymtmmD bamatgmhgdtemme d7815.12 14 Aampbseddrm dmwlrp darMurAabtrdwbbAdwdhrmte eetodmtlmdbW pwmbpepmbr,mob O I Dmt Symemrtrmeet mgmtamrob 47815.13 O VemOmim Sym mlommttagmtammb 47815.14 O STIRLINGROAD / SOUTH ELEVATION NORTH ELEVATION 1wb"o(PpbSSym =oommmgWmmmof7B13.15 �ff��'lll Sarah Wow HedhB Slant t Bghlpmrntm and regmtmenbL 4781521 �Tl U BleabirmRlJwih89ymemramemnaphammb4781s31 1.7b dob LMtBugdt®mb: BrbW6lerp°eaa4trhW6LheiAhmmtd tl�t grlaBfcdEoarmea w I— 2. VarOdmRspimm me4: bdKmdmylmd dp A Bob&"yme rooptHbhmr dbrlbocmr dmHhmeummd wmbYtlrgWID 4%dBamrms,a IWm0O mdl l mdrobm.emWimpo.IdeBnm(x)ek°Wm/rOrhar- ' 10 Plant a10MCO°vam00 B. ibohrrabow,a 150 Wlfinedrelo.lwmhrkm. Tdlh do code. n p C- Brfromr r atom Or 25 CPU mrohmloel"mdWm ap.. Q/yen'u+:ooA=- D. Agb dM ask &me*bamda. .�"',I. 3. Bemelq BmblWim°are) bdlM/eWm°MtmlahmwYhambim®dlmekndl8"demrl®rmYriYt DabLl_ �,fJ 3 'novo dor abnr A*dW Am. A SbYwWb doR IDA 3P wMmWmom,24P der. GENERAL NOTES: " bhmib dohbbloirade ApmtldmweWeahm odmrwMuobd APP)RU,VED AS NOTED Prerldrgpb.l rugyammr+bmrtr/pmtYieeA t, DATE: / as _B.PN azo/6- .Rr Phrpboe-pormeroopattrbmtmrepW. FEE: /7 . gy. P _ BDplmmsbb YsPhabd40yerCCA w16 E01 mrM. FEE:NOTBUILDING DEPART bharlde m0amM-bbN mr I dodd f WeW mebM9'•1•llr b4 scrod FOLLOWING INSPECTIONS: ° n . Yo:4"•1PaWdrweDL 765-1802 9 AM TO 4 PM FOR THE Fi ra4- Iroc' ' eW•mbmmmd otmwbr. 1- FOUNDATION - TWO REQUIRED 1y AO wA madr nbbe02arbahrpoadiarHc FOR POURED CONCRETE L ` Modmrlkmde{mmdle embbd2abmMDawrlBraotrowbmud 2. ROUGH - FRAMING & PLUMBING S. INSULATION Pow"Jobatoodilgi Ill bm - pobb- haNemmmadmLtl ooarmmrraaoYedtrAmrh mmluel bedloparEybhadYmr. 4• FINAL - CONSTRUCTION MUST I Olelopb bm M2a 10 hmdn•mmmoMrbreobd BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MELT hw�Wibalk�Wotrdddigm AwmY mmgOYed THE REQUIREMENTS OF THE NY. +DAC STATE CONSTRUCTION & ENERGY DESIGN OR CONSTRUCTION ERRORS I- F CODES. NOT RESPONSIBLE FOR CONC7dTB. /1 R Iit, F.i - . BYmp6-3A00?81m7AMA81MCA1wedym aataem. n ANp,tomdLhoa,e10.DAA Iett mmtdlmelbed edl I ... '. . .. Foodapdollb@34ribdowfliddodoxede OCCUPANCY OR M he&^dmrWmrrhBbelamed ((?? �� pp}�,�GG @ g ry I� VJe. �J 4�Y9��a SF��ILN�_ Dtmpl a -p uddopbeft—tv. �`,1p �9�R� I I Fe&�� 0 1 NOTE: al fl , g VERIFY ALL DIMENSIONS AND PCONDITIONS .. Lwp' 5"midammtdom CopdbabmyhapWry. _ ..._._ BbbbaomehmlbabbarfambdrNehmd IDeomoOode,NwYadLBhbBmmbpCab,d L4A . _- _ - ?mridamr rm6dWotraraohilomboYdudbmmomL h vlbawbdmmge leddmm*seLer. ABdLaalommebbedhoo*whodbee .. .. a iemlbdrplrmoftwbbM PROJECT NO: 738-2000 DO NOT PROCEED WITH w: FRAMING UNTIL SURVEY AWN C M A I lbmo6laBYbamh®b6�eb baso had&ay.I.mdmg hmm.b dNLwratweCada OF FOUNDATION LOCATION CHEGKEe Sf : l�'„H Br°ar.Aw.B.emem.Omorrnrdb.» d�yam.weebd.mowmw. HAS BEEN APPROVED. DATE: 09-27-00 11 I v4' r-o• PINE TREE ROAD / EAST ELEVATION = SHED TIRE: i ��� �,-SOA-Tm�J �wuey.in�6 S.TTs.1tKs .va elu/ Q PROVIDE SMOKE-DETECTING PROVIDE ANTI-SCALD AND/OR > ELEVATIONS ALARM DEVICES THERMAL SHOCK PREVENTING uta O 00 � AS TO PART. 721.1 OI SKLU PART. V m V � Q NOTES N-YS BUILDING CODE- N1 BUILDING CODE PROVIDE ALL PLUMBING WASTE C W OLL. Q Lull EMERGENCY EESINGS CAPEFOR E &WAAS R LINES NEED TESTING 8H-PORE COVERING o W j > o Ne REQUIRED BY PART. 714 OF '� Q ¢ > N N.Y. STATE BUILDING CODE. w � �` w {� If copper tubingis used —I J ~ I-�' .r OF PROFFS$IONAI.LIAFHL1 � � CO)y X 1 of 2 eYAc A',rl ISE CFTHESEPL NS THE OWNEAICOx Crow UNDERWRITERS CERTIFICATE for Water distributing O U y Lu AG ESTOIIMRTHELNRIIITYCPWARRFNA.LALaACHER, syStem; i Cnu HNG ANd1NWAma6EMFLQY DRTUNHAEC.ACTa REQUIRED P Ping shall be ,L, "•, ' OF ERROR SUCHTKATl1ETOTAL AGOREQAtEWm OFa ffl f Ot eS f_ �I A'sAMancxdncarubonwrmwntrmwamrRu Yp IC or L only p Nm CMD IOBLmpmo ObM AVI 'rAo .r �_ UNDERWRITERS CERTIFICATE } SII REQUIRED ADDITID •yam ' I �dY iA 'F EXISTING C14-5 WINDOWS (RELOCATED) _ . TOP PLATE / WALL HEIGHT SPLIT EXISTING C-14 WINDOWS .B AND ADD 1-1/2- SUPPORT MULLIONS TOP PULE / WALL HEIGHT (D'-9 ]/4' +/-) BETWEEN EACH UNIT (e'-R ]p^ +/-) (1) 2x4 PLAN OVER 4x4 HEADER _ e'-0 ]/a' WINDDW RDUG11 OPENING HEIGHT I}I� PROVIDE BEAD BOARD I EXISTING WINDOW 'WAwSCOTDNG` TO b' i$ TO BE REuQwD HIGH ON WALLS, I�TOBEEXISTING WINDOW F PROVIDE NEW CASED PROVIDE CHAIR RAIL AND TO I REMOVED DOW OPENING. BASE TRIM. �.: DOOR DOPENINO k' w WEAVE-IN At MATCH E%ISRNG WOOD FL00111NG 1a r% MASONRY FIREPLACE M W N" X zO VERIFY HEARTH SIZE f NEW I "�� I W MADEMICH USE O '� AND HEIGHT WITH OWNER � m vu5� p ON MNNO ROOK I F CONFORM i0 NIS CODE� 1 SUNROOM aH n 1 w ^ SIDE CO' nREPLACE NEW U STORNDEDE FIREPLACE. (vERPY WITH OWNER) I I PROVIDE STONE FACING VERIMY ALL DIMENSIONS i II I A ITL N 1 ON NEN '$UNROOIA SIDE _ AND CLEARADIM AS PER ^ ( 3 _ OF FIREPLACE (y NYS CODE. _ (VERffY Y1111H OWNER) +Z PROVIDE OUTSIDE AR - I Wp I'I" VERBY HEARTH SIZE � €i AS PER NYS CODE _ 0 Q o- - AND HEIGHT WITH OWNER, KJ'' IARCNII NRI1 c:MDPT N w CONFORM TO NYS, CODE MADE I) J-1/2' x 11-T/4 ANTHONY POWER REAM'Pry j PROVIDE CAS LOG INSERT ,^,� O 2 :D VLRIFY ALL DIMEN5gN9 _ _ _ _ _ _ _ ~�b (ASWPERDE POYMERS BPECIFICATIONS)ATIO A STEPS TO WADEIH ACCORDANCE wrtN Nr5 - RIDGE BEAM Ip NEW PATIPROO I Of W CODE AND MANUFACTURERS W N '-+- AND CLEARANCE AS PER, —_ —_ — — — A SPECIFICATxwS = _ _ _ _ _ — — — T a a •a (VERIFY w/ OWNER) NYS CODE — \ NOS. 3\ c.l Z5 [.^I O O EXISTING WALL ail ; TO BE WALL \ X q O PROVIDE WS CO AM TO BE REMOVED a . • ' A AS PER NYS, CODE � TO BE REuOVED V� In II'• PROVIDE CAS LOO INSERT WET BAR M) IN ACCORDANCE WITH HTS CABINET v J CODE AND MANUFACTURERS i SPECIFIGlIDNS crv'I N PROVIDE PATIO R STEPS TO GRADE W 4�i "I a (AS PER OWNERS SPECIFICATIONS) W Q ,1'I it P e, x VI r XISTIN XISTIN S 0 6' w LIVING ROOM SUNROOM ID 8 m P ylE lW^ W O('Y (I) 2.4 PLATE OVER 4x4 HEADER LL O 6-4 3/4' WINDOW ROUGH OPENING HEIGHT O EXISTING C14-5 WINDOWS F-T U SPLIT EXISTING C-14 WINDOWS R� 0— "' AND ADD 1-1/2" SUPPORT MULLIONS BETWEEN EACH UNIT ,F a5. 5X /Z 3C6sr II ;' A FLOOR PLAN 1'-]l EXISTIN A FLOOR PLAN - STRUCTURAL P ADDITID ° NEW STONE CHIMNEY 12 � � �? '� ..° �6 1/2" +/- ROOF PITCH lyt, I I� 11.' (1) 2x4 PLATE OVER 4x4 HEADER 1 - 6'-4 3/4" WINDOW ROUGH I I I 25 YR. ARCHITECTURAL GRADE ROOF SHINGLE NEW 2xON °c I _ OPENING HEIGHT ON I Qj 15# FELT I xO 2 2x6 CCA SILL PLAT 5 I 3-,1/2" x 11-'7/8" ANTHONY POUTER BEAM f I I 6 MIL POLY VAPOR BARRIER (4CH1I 0WIRAL GRADE) 4' (R-30) HOMASOTE ROOF INSULATION / DECKING xON RIQ�"jE, QEAM u I NEW 4" CONCRETE SLAB I I 8' PC. FOUNDATION ON o j 2x6 T&G SPRUCE ROOF DECKING w/ 6x6 WWIA I 16" A 8" CONIC FOOTING F- ' ' vEAA 4x8-32" oC RAFTERS (SELECT DOUG FIR) :u : -D l I Iplo I' MIN. 3'-0" BELOW FINAL c 1 MIN. 1.5 MODULARS Of ELASTICITY x ¢ NEW CHIMNEY FOOTING k PIER l I GRADE ¢ NOTE: a l 4 ¢ J 3'-GONG 8'-0" xG12 I I iu a \a I I VERIFY ALL m mo MIN 3'-0" BELOW FINAL GRADE I �pj TOP OF NEW CONCRETE DIMENSIONS AND NEW FIREPLACE h L WWEY LL a, DWTACKEDTLE STONE . _ ?' VERIFY EXACT LOCATION AND SIZE I I SO :I SLAB TO BE 3" BELOW CONDITIONS �I A VERIFY ALL SPECS, w/ OWNER 2x SOLID NAILER a �o I Y qp TOP OF EXISTING SLAB NI I Z, MASONRY FIREPLACE I" A Vhf 1" x 4" FASCIA 3 VERIFY HEARTH SIZE N hI I I MATCH EXISTING FIRST S N800� AND IYENGNO WOH OWNER SUN800 CONFORM To Im Com I �^ I FLOOR FINISHED FLOOR I� 6" VENTED SOFFIT I I HEIGHT. :D PIMA r 40: f 2x4 PLATE ON 4 x 4 HEADER VERIFY ALL DOME SIGNS tl'-3 738-2000 5/8-CDX SUB FLOOR Y MATCH EXISTING SIDING HITS CODE CODFAMNCE A$ PER I — — 2 -A 91 P TEs I' MATCH EXISTING LI U I C M A I ( ) w/ 6" EXPOSURE. DaAWH IW PROVIDE OUTSIDE AIR MATCH EXISTING R-15 NSULATI N 151# FELT As PER N.s. coDE N 1/2" OSB SHEATHING PROJIDE GAS LOG INSERT CHECKED RY WOOD FLOORS 2 x 4 - 16' oc STUDS Lw' ACCORDANCE IITHH ERRS 2 x 4 SHOE I 09-27-00 CODEI AND MANUFACTURERS I Are: 2 x 6 CCA SILL PLATE - TERMITE SHIELD k SILL SEAL ? SCALE 174• = II-0• ANCHOR BOLTS (8'-0" OC MAXIMUM)' 1411 AMP PROOFING I Fx cnN. CONCRETE T o R-19 INSULATION R-19 INSULATION 8" PC FOUNDATION I SET ON EXISTING CLANCRETE SLAB w EXISTING 2x6-16" oc NEW 2z6-18" oc 4' PC SLAB w/ 6x6 WWM I I � 2 x 4 KEY WAY I m _ 7(2) 2x8 CCA SILL PLATES 16" x 8" CONCRETE FOOTING I PLANS w �4 ILJt�r[ '% 6 MIL POLY ON MINIMUM BARRIER MINIMUM OF 38" BELOW I FLOOR PLANS FINAL GRADE. (TYPICAL) {� INSURE SOIL BEARING CAPACITY — — — — — — — — J CRQ $ SECTION A - INTERIOR ELEVATION WALL HEIGHT & HEADER DETAIL - - - - - - - - - - - sEcnoNs III . t STUCCO ENTIRE EXTERIOR OF SUNROOM FOUNDATION 1— ;)•_l1�' gpDIT10 SHEET a11I (OLO, k NEW SECTIONS) _ TUN MATCH ON G HEIGHT OF NEW SIDE 3" SID LOWER,if I" /� O� ^ ' (J� L RU MATCH $O NG HEIGHT U NEW SSIDE 3" SIDE. o r, ' '(DW T0, 3" LOWER FOUNDATION HEIGHT) FOUNDATION PLAN - STRUCTURAL I�il nr , I X� Ilk k u. it .,I BUILDING CONSTRUCTION NOTES: NEW ADDITION h EXISTING SUNROOM ylf cm11E¢AL: �„ nl d ENERGY CODE CALCULATIONS (pa.ydpo-gaydc ) 1. AlomWwdmwasteland comply wiltslattern,York Smi BWWingC4mk"mCoddadwiththemgwkemmmdoayVessel dtpmb en*as wall as do rdq,themdde of m>ma8isknitjmi,dbdm. _ DadEO Crbwb: 6000 Diagram Syr 2. Allwe&di am*with the New Yoh SrroBm{y code. "1r1 O.A.10 Depwa Fahmwbmk A B"betheomhwW myowgblltybm6mbdwsickdmiry,m6lyp Mmeohw"gMamawhiohwiUbemeaio L4-70 DegraalyahrmoheB samobnt deal a acquired by do t< BudI Deprasul B. Immhlew8doobmdpkf n-oquit byml i , C. Al wiodmm,doarelb,opmbp,ab.drl beeand and wentha shipped. SUBSYSTEM AREA DESIGN 'U" THERMAL RATING REMAEIfB 3. Provide as make htmtor m aahloan boludh�bmummL AovWaowohedvwkcsinzBdrepingm . ABdewmwrmob bodko*wiWw*eekobWrf rmofbebrme. .. - Hxterior Walla 272 .067 +27 R-IS INSULATION 4. Engineer a mal depend fa the supeevaonMounarmtiaw Osurd Cumnssor mMvadfy dld®mfaas and oowdh•oos bdhm ' oowdhoWa a 6heiadfm Eosbwr it at rapoadbie he dry obOWS Is thout wdwa prkrmpryord. Gbziwg Does 40 .34 -6 ANR)ERSEN HP oR EQUAL 5. Dom -.. . _ . . .. .. .. . . . . . Wbdovva 123 .32 -22 ANDERSEN HP OR EQUAL 6 1b, gi doll be Timpani �coomtlrrctiaa moreempsnly. HOSW M&ao�leiblo alolaRml*IN amelbodr .. .-. _,. . .,. ...... .. V Dome • ..... _. _. . ... .. . ._ mttaas and agmrpmmDElectrical,Hmhiog EWioP,Ventilation,An Candldcohy,aay othm rysom mot specifically .:.. . . combed to dime dram. .. .:: . .. . . .... . .. .. .: . .. Ceiling(FIm) r l; 7. Bomb conducted Is to WnhAm to dw)hdmd Moulde Code.New Yak Bae Cods,and LDA J ..., . ., Cmlbg(Cstheded) 346 .033 +5 R-30 INSULATION I r a 8. Plandift is b nonfarm btW Comely and Load HUM Department mpdeemmb,sell Code. O O ' Skyli�ila - 9. All hal proltaft equipment AWB be installed in wmdmm will,NYS Code mdmm Wkftm dpKftMom. i'., Floor 304 ,053 -2 R-19 INSULATION lid - 10. Al eWoulod and mechanical aq:dpmem b b be elevatedb FEMA aguiormem and NYS Codo w re"Ired, — , .� Foundation Walla -- _-- O ll. LWlatfon MPmhediowd Labllity Li ELISlab Insuda w By acceptance and osu ofbmpiece tiea omaa/bo0dm/asset mean So lead the obllty of Bed End Deg land Deal and 1�'1 Q w leak drdlmm due b mqlad,ab Mare,Ash amt the bbl WaWm WMlity MEW End Drmlms R Deal ad TOTAL: +2 Ihm thNmen hell sal aaeed site toad he for Amviom rodded mside project. - 12. AS Mac hmrpkm mdrbvadmm m protected omit bddd oopyrisbaw. Nophn may be mpsudoud ereomuacard wall wddm parmbdm W W � - - - - - - - - - - - - - Building Envelope Systeme to meet requirmwme M 7815.2 13. Owner/CansuloruM rally mydue spnal reschedules brdue owdmodm sora a flood omerpotremW6 nG co D . _ HVAC Hgaipmmr to meet mqw mmmla of 7815.11 y HVAC Systema to meet mphe mm of7815.12 14. Aocepaoco Mtlaedawap daaWsatharve the rykbbWld wllhcat the amthodatko ofioalsmvmiag dlemeid.ask 1r1w�1 O O Duct Systems to amtmquhemmnb of7815.13 Town Building DepmdmeW,DBC,o1c. CL Q 41 1t STIRLING ROAD / SOUTH ELEVATION NORTH ELEVATION Vcndamoo Systems;to mastroounce mb of pkmm of Insuhtim of Piping Systems m mewl tequhvmma meet 7815.15 14 O 'J Smice wear Resting synems&BgnipmmEtm meet tegairmma M781521 0010114301,1111111 BleoBial d IJghtlrrg Systems to mel roqultemewts M 7815.31 W 1. Light Reg®coma: FLhNWa Apmco wtcapt re ldbhvwd hal lave Wed lists egad b6%ofloa ma �- 2. ventilation Rpahmma Toto bed of my knnaljud , A Hmbmble spmen Mobkbmr and brboom;hell hive named ventilation equal a area,Ill ofloa,a U belief,and professional ja ®went, mmWpkd vmmMim pmidag two(2)=oholmpm6om. Ste ppm in compli� ' B. Eik6as as above,a 150 CEM mathabd vwulls" with to code. C. Sahmcros as above,r25 CFM mmhmimi ventilation. SiWbdV" cdGl@wl ' � D. Al has deal nhaedimdy to wnarinr. V/ 3. Semodry Bda(Wbdoa) doll be 4 pads,fad mbiam with miolamdhosudm Mlradmmodmmddlbd& Dried //l�1Lu✓ S 2�1 M42"obnn/mshedlar, 4. &Wwdb Ahd1 be 36"wlh medical 8l•elm. i � GENERAL NOTES; I *.i li Eli '' CARPENTRY: Provide doublejaha now RU plus tWmwam roam andwidewated peal""away Cam+Joel pMida : $I Fheplece-Poll support bur hath as rapdred, Sill places me so be 2•x 6"bend 40 year CCA with eN oda. Provide dU under-bely rtamite Kidd WmOs mlobe ff-l-ll8•tri a m noted. - 2"x 4"-l6•w oxalo wda o 2"x9•-16"co babe 2a be ft emend Fit. . All wdlAbdsmbop2abmm Douglas Fra. All all hrahp mambmm to be d2 our better Douglas Fkaod wrbemad i. Qp Provlde olddmg F bsumth all bas acquired Provide oonN mel command,nregdnd 6m all laAhmmnvd bsNos mryilg conditions. Opmlopbhave(2)2x 10 bemdm-mina athdwlle wood. a r Lag bolls All gad plpe.. PmHde fee blod ft on all walls as required. 9hmMM-3,MPSI d 28dty ASTM C•94 nedy mh omaeb. Al fadhp,fomhdone6 els"asst mmdYmbed earl. so FootLW doll be 36•briar 6nhWd Weft-maims. r Mmoly"Passed ftmwm wish 9lgedfoodng. All 'x r wfoamatlo ter an o forced. Pmvldeaahmbgbulurs'mwdwellov Wdog2'-0"bdbwlWWore. (r-0"x 8'wills 3.#5rebar m 16•x 8•coworeee foabg) NOTE: Imppraofiog-pmvidepaMk ovassr. VERIFY ALL. DIMENSIONS AND ELE=CAL: CONDITIONS � a Resp boxy 5"ma®d km edge ofbox to rough opeal Moobk oonsh"m b toodrAlm btheNmdmd Electric Co4kNew Yat Sae BWWW Code,ad LDA - PmrldemeawbdMMmmmhloor,bctuftbnmsuL PtwAft olmdMabnadldmpb/rem. AldMmbmm iDWdkedlywWdbtim PAWECT No: deamlalsystem Mdid boom. 788-2001; onawN m: C h1, A PLUMIll '- v 'v CHECKED eP ^ ' Supply pips bwmW(fwwm)d 3"6amplywood - - - _ - - PlmMnga b cake b he costly ad lead MhhddpwMW requirement ndNm Yak Sea Code. RelooMe dl w.0 add henna mMMrma[hoan,swd sprryb sunk moeshbye ala. DATE; 09-27'-00 scull: 1/4' PINE TREE ROAD / EAST ELEVATION SHEET irteE: � ELEVA'TIONS. ,^ s _ NOTES SFIECr ND: _"� 1 0f hI : I ;j, 1 'Ile , T 1- ,N 1'-I1 ADDITIO ;i EXISTING C14-5 WINDOWS (RELOCATED) /LOP (6PLATE / WALL HEIGHT SPLIT EXISTING C-14 WINDOWS TOP PLATE / WALL HEIGHr ; '-9 3/4' +/-) AND ADD 1-1/2" SUPPORT MULLIONS BETWEEN EACH UNIT (s'-9 a/.' (I) 2n4 PLATE OVER 4.4 HEADER 1".tl 6'-4 3/4' WINDOW ROUGH ffV+V ' OPENING HEIGHT - W II PROVIDE BEAD BOARD-� I?I AA �.EXISTING VnHDOW 'WAINSCOTTING' TO 46' IIS U • 8 TO BE REMOVED HIGH ON WALLS TO BE REMOVED LO ¢ - n) D PROVIDE NEW CASED PROVIDE CHAIR RAIL AND ¢i PROVIDE NEW CASEp C C w M) Y DOOR OPENING BASE TRIM ry'H ' W( DOfiR OPENING �y S' v WEAVE-IN A, MATCH �C-''J,4 �U' �' Q ' EXISTING WOOD FLOORING y k MASONRY FIREPLACE t 'V W p H- K w VERIFY HEARTH SIZE -- NEW '0 PROVIDE USED '~�'-+ BRICK FACING .Q 4 AND HEIGHT WITH OWNER IO V1F p L_ ON LIVING ROOM 1 / -1 cor4Foau To Nrs CODE ) / SUNRO M < Zn tt wY SIpE OF FIREPLACE NEW z- SIDED FIREPLACE C4 - j4 (VERIFY WITH OWNER) PROVIDE 570NE FACING VERIFY ALL DIMENSIONS A NITON g ` ON FIRE LACE. SIDE AND CLEARANCE AS PER OF FIREPLACE. J ' NTS CODE (VERIFY WOTH OWNER) 0�Z IY Z NASONPY FIREPLACE In d PROVIDE OUTSIDE AIR ,f w0 VERII HEARTH SIZE ¢ F AS PER NTS .DOC Q Q r AHD HEIGHT WITH OWNER nl J w I 3-112" v 11-7/8' ANTHONY POWER YEAH iv J w CONFORM GD Nf5 CODE j b O S 3 PROVIDE WS LOG INSERT r ) O CD I O �p ,�C,A' (p -O (ARCHIROGE RAL GRAOEI �D O PROVIDE PATIO h STEPS C IONS) IN E AND MANUFACTURERS WITH NYS - NEW PATIO .'I!- IO RIDGC BEAM 3 ti VERIFY ALL pIMENSIDNS _ L+ p: � � � (AS PER OWNERS SPECIFICATIONS) CODE AND �MNUFACTURERS m 4 � ro jp AND CLEARANCE As PER — _ _ a a ' o - sPEancnnous = — — _ _ _ ± a a :o (VERIFY w/ OWNER) ¢ h NYs CODE — — - - - - - Nm - - - . "ICO `EXISTING WALL `ExsnNc WALL F' "T `rr/ PROVIDE OUTSIDE AIR TO BE REMOVED R 0 70 BE REMOVED - � MI� � l�7 � 1>— AS PER NK CODE _ PROVIDE CAS LOO INSERT `WET BAR p IN ACCORDANCE WITH WS CABINET 111 V CODE AND MANUFACTURERS h IA to \N 7 \� PROVIDE PATIO k STEPS TO GRAPE 1 SPECIFICATIONS Ip c tt g O UI Q G� lA5 PER OWNERS SPECIFICATIONS) .< J LL � ' r� QUO n0 Z ' 1 a,GO CCOw TO w 1 o'c� - EXISTING EXISTING ��5 �a�, w , 'T _ LIVING ROOM SUIVROOM nWo N �� [I ,]' ".'d s II) 2z4 PLATE GIVER 4,4 UGH ��w+�J. 6'-4 3/4' WINDOW ROUGH '^ 11 OPENING; HEIGHT ^' �-O�yy � W EXISTING C1.4-5 WINDOWS (� � SPLIT EXISTING; C-14 WINDOWS AND ADD 1-1/2" SUPPORT MULLIONS .J BEIWEEN EACH UNIT (,) �J . A.i A s �� S._II3• � 5'-I1�' d k PLAN FLOOR —It'-II�• E%I CT IIJC�-- ] -j FLOOR PLAN - STRUCTURAL -11�- AUDI IIu 9 Y,,, � NEW STONE CHIMNEY �� 12 1 �6 1/2" +/- ROOF PITCH12) 14 C9A_2ki,_PIATES ri LL 11) h4 PLATE OVER 4>4 HEADER I.I 6'-4 3/4" WINDOW ROUGH NEW '2+6-iG" g 25 YR. ARCHITECTURAL GRADE ROOF SHINGLE OPENING HEIGHT ON 15b FELT N (2) 2x6 CCA SILL PLATES A (1) 3-1/2" x 11-7/8" ANTHONY POWER BEAM F 1 �, 6 MIL DOLT VAPOR BARRIER + S: (ARCHITECTURAL GRADE) NNSIULAT�l " HOMASOTE ROOF INSULATION / DECKING i ON )j RIDGE BEAM = NEW 4" CONCRETE SLAB �. MONOLYTHIC POUR R . PRUCE ROOF DECKING W/ 6x6 WWM ��1ELATION MIN. 3'-0" .OW FINAL GRADE Qo x `T � w +� NEW CHIMNEY FOOTING & PIER NOTE: DPWY c RAFTERS (SELECT DOUG FiR.) + i '-D S ISI ,° a f" D� ODULARS OF ELASTICITY rv, `'�,t J 3 0" + 8 -0 x 1T AI 'S' TO �A CyrG v¢ �a '.;UNC PlO11NG 5 yapjr '' y�� ���y�;, W*f'Lf' NEW FIREPLACE k CHIMNEY F\q 2 p 1T a V: P OF NEW CONCRETE Ma MIN 3 0" BELOW FINAL GRADE ��.i ��j C' �(MENS(WE�a➢ '1 DRY' MANE STONE \ v3 1- VERIFY EXACT LOCATION AND SIZEWOOD pA$I AB TO BE 3" BELOW C (T'( � VERIFY ALL SPECS w/ OWNER ` 2. SOLID NAILER MASONRY FWEPNCE , '� P OF EXISTING SLAB. 3 AND HEIGHT WITH OWNER Y �I F,+.1 (, ' 1" K 4" FASCIA j ¢ -� ITCH EXISTING FIRST AMR EIGHT WITH SIZE I SUNIF CONFORM TO NYS CODE G POR �p PRQJEC ND:. B" VENTED SOFFIT OR FINISHED FLOOR VERIFY ALL DIMENSIONS --]D -II •_ 1 !�t0 26gR -2x4 PLATE ON 4 x 4 HEADER AND CLEARANCE AS PER _ — - v-. JVV V 5/8-CDX SUB FLOOR L� MATCH EXISTING SIDING NYS CODE a z.a rcA SILL PLAT s (MATCH EXISTING) LI w/ 6" EXPOSURE PROVIDE OUTSIDE AIR - AWN m C A MATCH EXIST15N FELT AS PER NYS CODEWOOD FLOORS t 2" 058 SHEATHING/ PFOVIOE GAS LOG INSEFT CHECKEp BY; '7 2 x 4 - 16" OC STUDS IN ACCORDANCE WITH MYS 2 T 4 SHOE CODE AND MANUFACTURERS SPECIFICATIONS - DATE, M xf7 fAVA }/7 L 00 2 x 6 CCA SILL PLATE - TERMITE SHIELD do SILL. SEAL z { ' - - — - - - - - i/Z" x 12" ANCHOR BOLTS (8`-0" OC MAXIMUM) xl`;TINc 6-16" �1 SCALE �� R-19 INSULATION / R-19 INSULATION / -AMP PROOFING SET ON EXISTING CONCRETE SLAB x � 12" PC FOUNDATION - MONOLYTHIC POUR w SHEET COLE:' I ,1 EXISTING 2x6-16 oc —'NEW 2x6-16" PCI. 4" PC SLAB w/ 6.6 WWM yI 1 (2) 2.6 CCA ON ILL PLATES 12" WIDE CONCRETE FOOTING /'� pp` ��{{���;;����{{11 A 6 MIL POLY VAPOR BARRIER MINIMUM OF 36" BELOW FLOOR 1-LR'll1'Y{f,71 { FINAL GRADE. (TYPICAL) INSURE SOIL BEARING CAPACITY CROSS SECTION A - INTERIOR ELEVATION WALL HEIGHT & HEADER DETAIL - - - - - - - - - - - SECTIONS NOTE STUCCO ENTIRE EXTERIOR OF SUNROOM FOUNDATION A swEEF raD: (OLD & NEW SECTIONS) u5 11' ' ADD1T]❑ fIY I TN OMATCHGON SIDINGXISTING HEIGHT SOF NEW SUILOWER, NROOM DE AI + S (DUE TO 3" LOWER FOUNDATION HEIGHT) hl FOUNDATION PLAN - STRUTURAL I , ITT