Loading...
HomeMy WebLinkAbout29343-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-29776 Date: 10/20/03 THIS CERTIFIES that the building ADDITIONS/ALTERATIONS Location of Property: 450 BAYVIEW AVE GREENPORT (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 52 Block 5 Lot 39.1 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MARCH 25, 2003 pursuant to which Building Permit No. 29343-Z dated APRIL 29, 2003 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ALTERATIONS, DECK ADDITION AND COVERED PORCH ADDITION TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to LILIANA NEALON (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO_ 1148727 09/04/03 PLUMBERS CERTIFICATION DATED 10/16/03 DINIZIO PLUMBING & HEAT Authorized S' nature Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29343 Z Date APRIL 29, 2003 Permission is hereby granted to : LILIANA NEALON 53 WEST 94TH STREET NEW YORK,NY 10025 for INTERIOR ALTERATION AND DECK ADDITIONS TO AN EXISTING SINGLE FAMILY DWELLING WITH FLOOD PERMIT AS APPLIED FOR at premises located at 450 BAYVIEW AVE GREENPORT County Tax Map No. 473889 Section 052 Block 0005 Lot No. 039 . 001 pursuant to application dated MARCH 25, 2003 and approved by the Building Inspector to expire on OCTOBER 2 , 2004 . Fee $ 250 . 00 Author ' z Signa t'�'� COPY Rev. 5/8/02 Form No.6 - TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN IIALL Z ( 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with Co A. For new building or new use: L Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commcrciat building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Plarming Board Approval of completed site plan requirements. 13. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing'l land uses: 1. Accurate survey of property showing alI property lines, streets, building and anusual natural or topographic features. 2, A properly crnnplctcd application and cousenl to inspccl signed by the applicant. If a Ccrtificafe of Occupancy is denied, the Building ht.apeclor shall state the reasons therefor in writing to the applicant. C. Fees L Certificate of Occupanc% - Neer dhr clling 9,25.00, Additions to dry clling$25.00, Alterations to dwelling $25.00, Swimming pool 9+25.00, Accc,,son-building$25.00. Additions to accessory building$21,00, Businesses $50.00. 2. Certificate OfOccupaneyonPre-cxistinglitulding- $100.00 3- Copy of Cerlificafc of Occupancy - $.25 4. Updated Ccrtilicafc of Occupancy - $5O.00 5. TcmpoaalyCultihicItcofOecupenct - Resider(iulSli00, (bmntercial $15.00 Datc_ I 0 3 Nese Constntction: Old or pre-existing Building: (check one) _ _ Location of Property: _q5o__ blouse No. / Street Hamlet Owner or Owncrs ofProperty: L I u. IA 0a Suffolk County Tax Map No 1000, Section _Block_ S Lot 3 9 T / Subdivision Filed Map. rr Lot Permit No. _Bj y L l u l A .J A L� 3 3 — Z Date of Permit. Applicant: _ cAL-.ar.J Health Dept, Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate _ Final Certificate: L/ (check one) Fee Submitted:,$ ��_ _?_ aC, U C 6 qQ/ pplicant Signature O�gUFfO(,�co ti x Town Hall,53095 Main Road p Fax(631)765-9502 P.O. Box 1179 A Telephone (631) 765-1802 Southold, New York 11971-0959 ��! * BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: /0—k—o 3 Building Pennit No. Owner: L4 e j,,,, Nej al (Please print) Plumber: 0,N0 j Z1,6 1 (Please p ' it) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. I ( lm ers Signature) Sworn to before me this day of cb6 e�, 20_ Notary Public, JI� �cCounty Ilet�NpPi6N�.ObYq � No.01006095 , Tim Elryilp��.l� D rJ'rJrJ'c,nrJ�rJ'�n�nrJ��nrJ��nrJ�r�rJ�rJ�rrrJ�rJ'�rJ'rS�nrJ'rJ'rJ�rJ'rJ'rJ'rJ'cnr�r�r�rJ'r�cnrJ'rJ'cnr�rJ@nr�rJ'cnrJ'�nrJ'rJ�cnrJ�rrrJ'rJ'rJ'r.ncnrJ'rJ�rJ�rJ'rJ'� o 5 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 SBUREAU OF ELECTRICITY e5 55 40 FULTON STREET — NEW YORK, NY 10038 5 5 CERTIFIES THAT 5 Upon the application of upon premises owned by 5 5 5 5 JAMES SHAW LILIANA NEALON 5 1000 9TH STREET-#74 450 BAYVIEW AVENUE c�C�C�CS GREENPORT, NY 11944 SOUTHOLD, NY 11971 5 Located at 450 BAYVIEW AVENUE SOUTHOLD, NY 11971 5 Application Number: 1148727 Certificate Number: 1148727 5 5 5 Section: Block: Lot: Building Permit: BDC: NS11 55 Described as a Residential occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, described below, located in/on the premises at: First Floor,Outside, 5 5 5 5 5 was inspected in accordance with the National Electrical Code and the detail of the installation, as set forth below,was 5 5 found to be in compliance therewith on the 4th Day of September, 2003. 5 55' Name 4TY Rate Ratin Circuit Tyne 5 Alarm and Emergency Equipment 5 5 Sensor 1 0 Smoke �5 5 Wiring and Devices 5 5 Receptacle 11 0 General Purpose 5 5 Switch 11 0 General Purpose 5 Fixture 4 0 Incandescent 5 Paddle Fan 2 0 5 5 Receptacle 1 0 30 amp Dryer 5 5 Receptacle 3 0 GFCI 5 5 Service 5 5 rj 1 Phase 3W Service Rating 200 Amperes 5 Service Disconnect: 1 200 eb 5 5 Meters: I 5 5 5 5 Sea, 5 5 5 I of I 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 D rJ�rJ�rJ�rJ�rJ�rJ�r�rJ�rJ�rJ�cP�.P rJ�rJ�cPrJ�rJ��PrP rJ�rJ�rJ'cP[PcJ�rJ�cPrJ'rJ�rJ�r�rJ'or.Pr1'r�[Pr�r.Pr�rJ�rJ�cPcPrJ�c1'cPrJ�rJ�r.PrJ�r�rJ�rJ�rJ�rJ'� �PrJ�rJ� o -p'A\q� APR 29W ' Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code RES checkSoftware Version 3.5 Release lc Data filename: Untitled.rck TITLE: Nealon Residence, Interior Renovation&Porch COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric DATE: 04/25/03 DATE OF PLANS: April 17, 2003 kl �1 PROJECT INFORMATION: �61� Nealon Residence 450 Bayview Avenuerc , `°' Southold,NY 11795 1cs Q Tax Lots: 1000-52-05: Lots 38 and 39 � �� `vo, pg2� y® COMPANY INFORMATION: OF t4 Susan H. Frooks, R.A. 21 Central Drive Plandome, NY 11030 COMPLIANCE: Passes Maximum UA= 83 Your Home UA=56 32.5%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 320 0.0 38.0 8 Wall 1: Wood Frame, 24" o .c. 432 18.0 0.0 25 Window 1: Vinyl Frame:Double Pane 5 0.500 3 Window 2: Vinyl Frame:Double Pane 4 0.500 2 Door 1: Glass 4 0.500 2 Door 2. Glass 4 0.500 2 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 320 21.0 0.0 14 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York Stats Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, then are attesting that to the best of his/her knowledge,belief, and professional judgment, such plans or specifications are in compliance with this Code. TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET tq VILLAGE DISTRICT SUB. LOT •?L r, n L i 4 a vtA ca-Lo—Y PO - RMER OWN,�RN E ACREAGE �1L S W TYPE OF BUILDING 7 RES. '.�/b SEAS. VL. FARM COMM IND. CB. MISC. LAND IMP. TOTAL DATE REMARKS 66 — ' L r1 oa -Lnizt�7�fzy- uY Fsi— fr, Akel > , t7 OD-b i( co � 9aO � 3 �� 3 a - � � t O �� (� OYv(�✓l�L-P Z BCI��S �S�L-3�� ��1 --- 1 C) 0 AGE BUILDING CONDITION NEW NORMAL BELOW ABOVE Farm Acre Value Per Acre Value -41 — — — -- — - Tillable 1 -- Tillable 2 ----- — Tillable 3 - i Swampland Brushland House Plot Total ' jvM i'H T. TERRY T...•.. H:dl. S 3Dut I.1J111 It OJ l ' TOWN CLERKo '• r.o. n<I. 117a L� '�uududd. Nc..- Durk 111171 REGISFRAR OF VITA,STAT151CS .✓� lL� Fax 0 1(I, 765. t R'T MARRIAGE OFFICI'R �j y�� Tcicphaac ISI(., )(IC IHDI RECORDF S MANAGEMENT OFICER FREEDOM OF INFORMAT)ON OFFICER I OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION WAS ADOPTED BY THE SOUTHOLD TOWN BOARD AT A REGULAR MEETING HELD ON AUGUST 24, 19'93 : RESOLVED that the Town Board of the Town of Southold hereby adopts two (2) new forms to be used under the Flood Damage Prevent regulations of the Code of the Town of Southold : "Floodplain Development Permit Application" (FDP(93) ] , and "Certificate of Compliance for Development in Special Flood Hazard Area (C/C(93) ] . TOWN OF SOinl IOLD Southold Town Clerk August 25 , 1993 ` APPLICATION s PAGE I of a TOWN OF SOUTHOLD FLOODPLAIN DEVELOPMENT PERMIT APPLICATION This form is to be filled out in duplicate. SECTION 1: GENERAL PROVISIONS (APPLICANT to read and sien): I. No work may start until a permit is issued. 2- The permit may be revoked if any false statements are made herein. 3. If revoked, all work must cease until permit is re-issued. 4. Development shall not be used or occupied until a Certificate of Compliance is issued. 5. The permit will expire if no work is commenced within six months of issuance. 6. Applicant is hereby informed that other permits may be required to fulfill local, state and federal regulatory requirements. 7. Applicant hereby gives consent to the Local Administrator or his/her representative to make reasonable inspections required to verify compliance. 8. 1,THE APPLICANT,CERTIFY THAT ALL S ATE NTS HEREIN AXD IN ATTACHMENTS TO THIS APPLICATION ARE TO THE BEST E 1 O�VLEDG ,TRUE AND ACLCU TE. (APPLICANTS SIGNATURE) DATE SECTION 2: PROP ED DEVELOPMENT o c c m Ietcd by APPLiCAM1 NAME y /�� ADDRESSfl/ n TELEPHONE APPLICANT `y� JAfvN 4(V O � V��1,✓ A ` V QUTtI.� BUILDER ENGINEER PROJECT LOCATION: To avoid delay in processing the application, please provide enough information to easily identify the..project location. Provide the street address, lot number or legal description (attach) and, outside urban areas, the distance to the nearest intersecting road or well-known landmark. A sketch attached to this application showing the project location would be helpful q* 137 VI;t 15(/ FDP(93) APPLICATION _ PAGE 2 OF 4 DESCRIPTION OF WORK (Check all applicable boxes) A. STRUCTURAL DEVELOPMENT ACTIVITY STRUCTURE TYPE ❑ New Structure ❑ Residential (14 Family) ❑ Addition ❑ Residential (More than 4 Family) ❑ Alteration ❑ No❑-residenual (FloodprooCmg? ❑ Yes) ❑ Relocation O Combined Use (Residenual & Commercial) ❑ Dcmotitioo - R ❑ Manufactured (Mobile) Home (In Manu- 0 Replacement factured Home Park? ❑ Yes) ESTIMATED COST OF PROJECT S B. OTHER DEVELOPMENT ACI'IVITTES: • Fill ❑ Mining ❑ Drilling O Grading ❑ Excavation (Except for Structural Development Checked Above) ❑ Watercourse Alteration (Including Drudging and Channel Modifications) , ❑ Drainage Improvements (Including Culvert Work) ❑ Road, Street or Bridge Coustructiou O Subdivision (New or Expansion) O jndmdual Water or Sewer System _ E310(ber (Please Specify) lVwoVA ( 101`) After completing SECTION Z APPLICANT should submit form to Local Administrator for review. SECTION 3: FLOODPLAIN DETERMINATION (To be completed by LOCAL ADMINISTRATOR) The proposed development Ls located on FIRM Panel No. . Dated The Proposed Development: ❑ Is +fQJ located in a Special Flood Hazard Area (Notify the applicant that the application review is complete and NO FLOODPLAIN DEVELOPMENT PERMTT IS REQUIRED). located in a Special Flood HaW 4 Area. FIRM zone designation is /4 g 100-Year flood elevation al the site tr: Ft. NGVD (MSL) C Unavailable O The proposed development is located in a Goodway. FBFM Pancl No. Dated ❑ Scc Section 4 (or d 6 1 instructions. SIGNED '� DATE 309 3 f' r i APPLICATION PAGE 3 OF a .SECTION 4: ADDITIONAL INFORMATION REQUIRED (To be comnlctcd by LOCAL ADMINISTRATORI The appbcant must submit the documents checked below before the application can be processed: ❑ A site plan sbowmg the location of all costing structures, water bodies, adjacent roads, lot dimensions and proposed development. ❑ Development plans, drawn to scale, and specifications, including where applicable:details for anchoring structures, proposed elevation of lowest floor (including basement), types of water resistant materials used below the first floor, details of floodproofmg of utilities located below the first floor and details of eodosures below the fust floor. Also ❑ Subdivision or other development plans (If the subdivision or other development exceeds 50 lou or 5 acres,whichever is the lesser, the applicant tnust provide 100-year flood elevations if they are not otherwise available). IJ Plans showing the extent of watercourse relocation and/or landform alterations. ❑ Top of new Gll elevation Ft. NGVD (MSL). ❑ Floodproofmg protection level (non-residential only) FCNGVD (MSL). For floodproofed structures, applicant must attach certification from registered engineer or - architect. ❑ Certification from a registered engineer that the proposed activity in a regulatory floodway will not result in any increase in the height of the 100-year flood. A copy of all data and calculations supporting this finding must also be submitted. ❑ Other: SECTION 5: PERMIT DETERMINATION (To be completed by LOCAL ADMINISTRATOR) I have determined that the proposed activity. A. ❑ Is B. II Is not in Conformance with provisions of Local. Law rf19_. The permit is issued subject to the conditions attached to and made pan of this permit. . SIGNED , DATE If BOX A is checked, the Local Administrator may issue a Development Permit upon payment of dasignated fee. If BOX B is checked, the Local Administrator will provide a written summary of deficiencies. Applicant may revise and resubmit an application to the Local Administrator or may request a hearing from the Board of Appeals. APPLICATION s __ PAGE i OF a APPEALS: Appealed to Board of Appeals? O Ycs O No Hcarlmg data Appeals Board Decisioo --- Approved? ❑ Ycs ❑ No Conditions SECTION 6: AS-BUILT ELEVATIONS (To be submitted by APPLICANT before, Certificate of Compliance is issued) The following information must be provided for project structures. This section must be completed by a registered professional engineer or a Geeased land surveyor (or attach a certification to this application). Complete I or 2 below. I. Actual (As-Built) Elevation of the top of the lowest floor, including basement(in Coastal Hieh Hiszard Areas bottom of lowest structural member of the lowest floor, excluding piling and columns) is: FT. NGVD (MSL). 2 Actual (As-Built) Elevation of floodproof ng protection is FT. NGVD (MSL). NOTE: Amy work performed prior to submittal of the above information is at the risk of the Applicant. SECTION 7: COMPLIANCE ACTION (To be completed by LOCAL ADMINISTRATOR) The LOCAL ADMINISTRATOR will complete this section as applicable based on inspection of the project to ensure compliance with the community's local law for flood damage prevention. INSPECTIONS: DATE BY DEFICIENCIES? ❑ YES ❑ NO DATE BY DEFICIENCIES? ❑ YES ❑ NO DATE BY DEFICIENCIES? ❑ YES ❑ NO SECTION S• CERTIFICATE OF OMPLIAN E(To be completed by LOCAL ADMINISTRATOR) Certificate of Compliance issued: DATE: BY: Attachment B SAMPLE CERTIFICATE OF COMPLIANCE for Development in a Special Flood Hazard Area ,r I TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE FOR DEVELOPMENT IN A SPECIAL FLOOD HA7.ARD AREA (OWNER MUST RETAIN THIS CERTIFICATE) PREMISES LOCATED AT: PERMIT NO. PERMIT DATE OWNERS NAME AND ADDRESS: CHECK ONE: ❑ NEW BUILDING O EXISTING BUILDING ❑ VACANT LAND THE LOCAL ADMINISTRATOR IS TO COMPLETE A, OR B. BELOW: A. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19_ SIGNED: DATED: B. COMPLIANCE IS HEREBY CERTIFIED WITH 'PI IE REQUIREMENTS OF LOCAL LAW # I9_, AS MODIFIED BY VARIANCE # DATED SIGNED: DATED: C/C (93 ) BUILDING PERMIT EXAMINER CHECK LIST DATE REVIEWED: a6/03 APPLICANT: " " ^"4 / E A`° DATE SUBMITTED: ,�12 S/03 SCTM# F� DISTRICT: 1,000, SECTION: So? , BLOCK: S , LOT: 3$ 3 SUBDIVISION:Q. )yw ml.R 41 pue�J ADDRESS: 14441 '44VA 1,) CITY: j >oeTj ZONING DISTRICT: T_* CONFORMING? No BUILDING PERMITS OPEN/EXPIRED: BP -Z / C/0 Z- , INFO / /BP -Z/ C/0 Z- INFO BP -Z/ C/0 Z- , INFO ' /Y /BP -Z/ C/0 Z- , INFO PRE CO: Y OR N BP -Z/ C/o Z- , SINGLE & SEPARATE CERTIFICATION-REQUIRED IVO NOTES: LOTS 40,000SF-100-24.Lot recognition.(CREATED before June 30,1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger(A nonconforming at any time after 7/1/83) REQ. LOT SIZE: "/01600 ACT. LOT SIZE: )f,oco REQ. LOT COV. 202 ACT. LOT COV. ✓r REQ. FRONT 5 PROP. FRONT 3? REQ SIDE /o ?S ACT. SIDE REQ. REAR �*3 PROP. REAR REQ. EIGHT PROP. HEIGHT PROJECT DESCRIPTION: / )D``�t M TO 5 ,F. b. ESTIMATED PROJECT COST: CHIT /ENGINEER: 1Rcoe FAST TRACK 9,, WATER FRONT? NG DESCRIPTION: PANEL #: jfc�__FLOOD ZONE: AF COMPLIANCE: APPROVALS REQUIRED SUFFOLK COUNTY HEALTH DEPT: YES orED #): DTE: / / PERMIT #: TOWN SEPTIC RECEIPT: Y o� p'., NEW YORK STATE DEC: PRE-DEC 9/l/75 YES or SOUTHOLD TOWN TRUSTEES: YES oli TOWN ZONING BOARD APPROVAL: YES or TOWN PLAN. BOARD APPROVAL: YES o TOWN HISTORICAL PRE (SPLIA): Y o NEW YORK STATE CODE COMPLIANCE (S PAGE 2): YES or NO NOTES:, _-+> {o 6, xv np 'F�O,C� Z iA OA., FEE STRUCTURE: FOUNDATION: SF FIRST FLOOR: SF SECOND FLOOR: SF OTHER: SF INIT OTHER TOTAL TOTAL: _ 4 9 SF FEE FEE FEE 1. (_SF)- ( SF)= SF X $ _$ +$ +$ _$ ism 2. (_SF)- ( SF)= SFX 3. (_SF)- (_SF)= SFX FINAL TOTAL: $ so NEW YORK STATE CODE COMPLIANCE CHECKLIST e USE/OCCUPANCY CLASSIFICATION: � �`�°�. ' I k A i HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEE RESCRIPTIVEE 4N r -*A FULL FRAMING DESIGN ELEMENTS: HEADERS: YIN WALL STUDS: YIN ' GIRDERS: Y/N CEILING JOISTS: YIN FLOOR JOISTS: Y/N ROOF RAFTERS: Y/N LUMBER SPECIES AND GRADE: Y/N / DESIGN LOAD CALCULATION$ YyN SHOULD INCLUDE LIVE,DEAD,SNOW, SMIC AND WIND(INCLUDING UPLIFT AND EXPOSURE) WINDOW AND DOOR SCHEDULE: f MISSLE TEST REQUIREMENTS(S)N EGRESS 5.7 S.F.,DIGHT 8%, VENT 4%: YIN LOAD PATHS: Y/N ROOF TO FOUNDATION NAILING/CONSTRUCTION SCHEDU #N MEANS OF EGRESS: YIN .•+ PLUMBING RISER DIAGRAM: Y/N LOCATION OF FIRE PROTECTION EQUIPMENT,,�97N TRUSS DESIGN: YIN CERTIFICATION: YfN 1 ENERGY CALCS�IN I/ Q�f.P TOTAL COMPLIENCE? Y/N(RETURN TO PAGE ONE) 3 (13� 765-1802 BUILDING DEPT. /tNSPECTION [ ZL40/UNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: o , DATE 41c?-6 14:�,2 INSPECTO M-1802 BUILDING DEPT. NSPECTION [ /jOUNDATION IST [ J ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: DATE INSPE 765_1802 BUILDING DEPT. INSPECTIO [ ] FOUNDATION IST [ ROUGH PLBG. [ ] FO DATION 2ND [ ] INSULATION AM [ FRING [ ] FINAL [ ] FIREPLACE & CHIMNEYS / R ARKS: C DATE / o ;- INSPECTO Gi 3 L� M-1802 BUILDING DEPT. INSPECTIO [ ] FOUNDATION 1ST [ ] ROU LBG. [ ] FO DATION 2ND INSULATION [ FRAMING [ ] FINAL [ ] FIREPLAC A HIMNEY REMARKS: G DATE �- INSPECTO Y M-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUG PLBG. [ ] FOUNDATION 2ND [ ] IN CATION [ ] FRAMING [ FINAL [ ] FIREPLACE A CHIMNEY MARKS: � Ok/ �-Gen L�o`a DATE liw INSPECT M-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING 0 [ FINAL [ ] FIREPLAC HI NEY REMARKS: DATE9-INSPECT 2. State existing use andoccupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy F�Q-5D tj Ar_ (U—C> (o e ri cz b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition ✓ Alteration Repair Removal Demolition_ Other Work (Description)4. Estimated Cost �AZ Ot e r7 o Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars /11� >- 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front sem: Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front J Rear Depth 10. Date of Purchase !1 Y Name of Former Owner T4 V - 11. -11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO—Will excess fill be removed from premises? YES NO 4. Nunes of Own:x of pre,..ises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OFJ z_."I±? ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge a-id belief; and that the work will be performed in the manner set forth in the application filed therewith. Sw_ owi to before me this n day of_% r —a 2000 CTI Notary Public --QSignature of Appl ant ELIZABETH MALAVE Noiaty Public 5tn'e of New York Registrati; "053741 0ualified!, s county )oc1 My Commission Expires Jan. 16,2M N SURVEY OF PROPERTY `�• 1- AT ARSHAMOMA0VE 0 TOWN OF SOUTHOLD SUFFOLK COUNTY, N. Y. 1000-52-06-38 & 39 SCALE. 1'= ZW 10 /z 5� . y� JAN. 21, 2003 GAO COLA Vol J U. / O c�, 1 � vol � e 0 s / v,0 c 5 tE Of NE{y /moo a g`p�N t.AteTr�`QQf N0. 49618 NI Y P.C. ANY AtTERAnQV OR ADDInON m TN1S suRWr is A NOLA7IQV 5542. (631) 765-1797 LOT NUMBERS REFER TO "MAP OF SUMMER OF SECr4V 72ODI,Ir TME NEW YORK STATE EDUCA"M UM HA IGEN" FILED IN THE SUFFOLK COUNTY DAMPT AS MR SEC7?aV 7200-AMPWXLW 2 AU !7MWICAMNS CLERK'S OFFICE ON JULY 5, 1933 AS FELE N0. 1133. hVWM SA QOM CC04ES`UR MS" nW SOWM SEAAV CaRfSu 7WMWOr WSu WYM 1230 STREET WI0.9E STwATf/RE APPEARS WERE°"_ SOUTHOLD, N. Y. 11971 Oej-107 d FFr� COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES APPR VEDASNIM AS REQUIRED AND CONDITIONS OF �L DA E 3 B.P.F U SWMD7 MZBA DI 25Do0 BY: `� ^' SourNDIUmAMPIANNNGBOND �,�� g� NOTIFY BUILDING DEPARUNIINP AT N fl- 7*140 NAM TO 4PMFUAT a ' WLLOWNIG INSPECme.. - PIA N.YS.DEC d 1. FOUNDATKNI - W NE�UIIItiD FOR POU D CONCRETE Q' ' ' ,' I 2. F & PlUMWA3 IN F1 00n 7nNv t1? `� T . 4. FINAL - UCTk011 YLMiT a ) L E COMPLY WITH CHAPTER"46" „ ALL CONSTRUCTION 9NIW. MST FLOOD DAMAGE PREVENTION FNBOUIREMENTS OFTHECODOOF SOUTHOLD TOWN CODE. Y SULROUT _ _ - --"- - YORK STATE. NOT RESPONSMLE o E -- _ - - — DESIGN OR CONSTRUCTION ER CERTIFICATION OF NAILING & CONNECTIO lL REQUIRED. LU CCUPANCY R � •�;� � . '� USE I UNLA FUL N C` D LO Nom , �_ _' , - ' -4 - \ IFICATE w Q . WITH UTC LU w, OF0 CUPA CY 41 aI m — - – PLU 81NQ N a W EO "' ALL PLUME I G WASTE LO &WATER LI ES NEED ED N T ST 5, , . „ : 1N BEFO E COVERING � , 0 � NfrW —_ •14�y.1 ylr� ., In_,1 �)LS�' ,J �Lr���+;i'IIJI -I SrtJ Uri � AiK It ALL CONSTRUCTION SHALL PLUMBER CERTIFICATION MEET THE REOUIREMENTSOF THE E LEAD CONTENT BEFORE U,I'yf/i CERTIFICATE OF OCCUPANCY UNC€AWAI�4SCEATIFICAT���NEW'YORKSTATE. AECUTAED SOLDER USED IN WATER 11 / e SUPPLY SYSTEM CANNOT �i r1C p EXISTrr Bnc'rk `� �ni ,f G-1 KC '>> , , � XCEED 2/10 OF 1%LEAD, n- c/ C Wo�K -- I '• fpr,. � � ��'�/� NE' nils — — Ik.f I f, ) � _ _ � - .i -. � l,. JIB' ,ZII.0 , _ 1 L IroJ GV - ✓. Wy f:n c" 7 , �tevzbsFO —amu 1 { IT ED S, ) a nl 1 - - -- - - rJR — 7 - - /,+I h r j K 6r, go'.1 �J�IhruJlu.f• PNI �Y�ltl Kf R..[',f ' ___ - --_ -- (ND u1a;tK - ' _ I ilk I � '•-1 - - - -- - - - I ,1Ful 'Jn 'f°%V - p S x _ — G '� fry --I`-- � i•�'I �� - �I � — to"', - ---- -- 5' R-AII� ' _ •" — J}'i^I Ib AI - � � { '4Y 1. lfl'< OIJ -r�� � /-7 I ':4 IJ yy J p 9(i '' U F•K H 5 (y ra ,< 13 Z: 1 Ih!'iEkIUR RF.�1?✓,5,1=' 1 6XKI' IJr"U) _ I b � A r � I � �Q-a i� T- ✓`� q�' NG-«' InJ I N81d, I . . I - e i�,'�'p I I u.d w - —#— -_- . PLU NIE5IN RISEK �IAGf`'AM I z or I•IOT TO �.�A[�C � YIE ZONING CALCULATIONS a - W / _ - --- Existing Lot Size' (10b ft. X 150 ft.) = 15,000 sf , � u• - j i �" : I �� �', '� 1 ` Exist loor sod Po Fust Floora House: 893 sf ,N use Porch/Deck: 1 300sff l �K F j PN I�k15C At�Fi4 � j -- _ -- -- -- -,------�— �. Garage: 3455f 1,538 sf �_ i (� 0 ¢ _ ' c E _ _— --.. -_.-...,_I__�... _ 1,238 sf - . �• Z I �� I M ' _' �- - ',��I! 15,000 sf-1,238= 13,7 2 sf 15,000 sf- 1,53 8 sf =13,46Z sf Maximum Lot Coverage = 20% pursuant to Sec. 100.244 Nonconforming,lots Q _ 128 P1S7' Z - FA. _ Lotama= 150005f - - Proposed Building Area= 1,538 sf. Building Area/Lot Area= Maximum Lot Coverage N 3* 30' oOW,_ _ _ _ �RgoE ".I a J:: - I„ _ I - - - ii 1 Proposed Lot Co) < 0 1,538 sf/1 allowed) .10 - � � � NG'? Q• 5t)RUE`/ YVQE1W _. - , , _ f� AVENUE I EX1�P�G� cq Rfzy{;E-To EE_AL ` N.vu1 `�'-V�P 13% (Proposetl) < 120% (Maximum allowed) INFORMATION FROM lI ` -- _ - - L` ;i.: I x I- Yards - pursuant to:$el- 100.244 Nonconforming lots. 65 P Nfe' 6 RV WYO1 K,C, SF�IOI`(O � lCaC7U'S� 0538 � � -1 1 I' I I SQL , �, y r +. t— I L. we Propos LOr 40�, FROM "MAP OP — ---- ---- .— ---I---- -----I- -- — —. T _ _+. SOMMER NAUErJ" 7/533 Front: 35' 1 39.5'at new construction - I '" NFfi1 1"bvt I C�,y �i'"}J Ui"fJ + 31.1' (at existing structure) FK,E xt I133 B WAU._Z�I'�l. J__t'� �Wi I ,.JL i 10' 1 41.0' -J1•.L?--- =-� -- - ---------_--.. _. 'uJtiF..{�6- GI/*Pvk1''- PO�4'i Kr�•b1�t:iJ Both Side: 25' _49.3' Q F I N Z LL CONSTRUCTION LEGF.Nn Anchor is pie AnchorWalll Stud ewe I=ee a.z.v1 - - - - - Partitions or item to be removed washers as whet Batt"Plate eottam Plate 3be1 scop Existing item to`rernam E*7 (see 3Steel, - + 10, Concrete Masonry Unit, Fully Mortared Wood Stud Exterior Partition 2" X 6" @ 16" o.c. with II I I Ipl Plywood sheathing, air infiltration barrier, I' N „ s"1 Siding to match existing , Batt insulation between studs, Q ' -wall Stud nl'.f.i-1�(y' '/i•gypsum board on interior Lam' G Anchor Bolt lam,3.21.7&3¢.2.31 �IVII r✓t'.` �^��� ] '✓ r.L.i 1 .. 1-'. f Stetomel Plate Z Steel BbaP lappet molar Baltom I �l Y ` 7 h (ZI X l p Plate Isee 3.2.23) w t i 1-(I i) I � I-t Wood Stud Exterior Partition at Garage 2„ X 4„ @ 16"o c with Z :. Plywood sheathing„air infiltration barrier, I � E Siding to match existing n ' IC-11-W Existing Exterior Partition KI - 2" X4" @16" oc , Batt insulation between studs, �' - ' Full height, ah"foil backed rigid insulation g Bottom Plate Anchors to Slab-on-Grade gypsum board on interior a-- - — U) _ i IItI �I New 777= One Interior Partition, 2 X 4:@ 16" oc with 6F• rw Wafts 1 I _I" {R, - One layer 5/8"Firecode m l.�ilUlAKf Board on each side witha _ �p U�""j1 1 - Insulation between studs, " _ - I NArti,twr I ��—_-- -"U( I HR. LIU. �1 `} -- ' fi.tJ.(;height �. � p - +.1r3:',oa& I V ^ sone lave .... Gypsum on 2 X 4 @ 16" oc with Board on eacli side with Batt a+'N Insulation between studs, full height `� � Inur'-cif-r � to 1 f--� �I, . _� C> v d' -ro v' � �� — E ECTRICAL LEGEND �' to, 0 Smoke detector, hard wired Switch 1I xI <k3 3-way Swit,Ch � �� I�i' I afritry �"Y(r r x o . ;D Dimmer Switch k4 New Duplex Receptacle 'I s 111 T l I A i l ft i c� +h New GFI Receptacle JAI , •� Telephone Jack I Cable TV Outlet k 4 1 fl' �}' 1 � '"I'a; "1 � 1 We" ria• , �amtomnvmla New Ceiling,Fixture - yy^ yL�fi; T WMhm.olta and Sill Plate WanM1en as •wlrm 51" aneher blit rAneaor Balt( ' ls.a 32v77) / lace 321T&331.31 Fl 10 Ut Flo Iola[ Ts F0017 l4 y3__ _ M150-:Tf - -- /�-T /�` I PL-AH r / r 5111 Plate FOUNLit11S. N . + � -I�IV � Sill � Steel Shop1lapped unmt D- (`! � „ a Sill Plate Anchorage to Masonry Foundation Wall Hu-rlrt r_ . I_ ' 5/e el r ' 'j" NYS Ener Code �� - J 'iu1(� UJhL/-� u17.f/U BA>6 J /tel A. All new work shown on these drawings shall conform to the New York State Energy Conservation • KK// �I +� j 1�2°(7`/1•', �D ._ _- _ Code, Simplified Prescriptive Building Envelope Thermal Component Criteria, non-electric comfort heating (6,000 heating degree days). - Exterior Walls: R-18 Roof/ceilings: R-38` n i Floors. R-21 Crawl Space Walls: R-20 Slab edges: R-9 to 4' below grade W ft9-7" FIµF6, >' ) Glazing: U-0.35 t Wi No7E: ;xisr� � � c g V ' S111 1° - `�„ l{ ` Ike II�p - ,1, 'Sec. 602.1.2 "Where the construction technique allows the required R-value of ceiling insulation to be -A0 FIN; �� 9 r 7u UN�Iri p'6ATE obtained over the exterior wall top plate, R-30 shall be permitted to be used where R-38 is required." W ,Z LI _ Concrete Work Q �( 1 Concrete construction, placement and methods shall conform to The American Concrete Institute , � --1.= �'�` ���* standards and specifications. . —•__ -10_ +hu 1 2 Concrete shall have a minimum 28-da field cured compressive strep of 3 a y p strength ,000 psi. maximumI r. P i aggregate size /t . ++,,I 3. Admixtures containing chloride alts shall not be used. NEtJ C.MU'S llroR9"lIAtM%(J - ,� :, � 9 s 4 Concrete shall be "Ready Mixed Concrete" and shall,conform to ASTM C94. At time of placement, ` I ,I G concrete shall have a slump of 4" maximum (per ASTM C143). Materials used to produce concrete and �J� � �. fFy_ -G +v'1� f Y-> ft a:• -. i%\�,/ L -- - testing thereof shall comply with the applicable standards,listed in ACI 318. Portland Cement-ASTM C atter All - � 150; Aggregates ASTMC 33; Water, potable, clean,free of oils, acids alkali, ana�organic m concrete shall be thoroughly consolidated during placement using a mechaniedvlbrator rOu�D�'r0N 5 Concrete when placed shall have a temperature between 50 degrees and 70 Degrees F.Temperature ofj - t /SLE -C,7" concrete during mixing or transport shall never be lower than 40 degrees nor higher than 9i1 Degrees F. During cold weather maintain concrete at a minimum temperature of 50 Degrees F for 3 days and above 32 Degrees F for 14 days. During hot weather (ambient temp above 80 Degrees F) Contractor shall " " ' ( r • - take proper precautions as required to minimize temperature and shrinkage racking of concrete. 6 Design,fabrication, installation,and removal of concrete formwork are responsibility of Contractor. ' • - 7. Anchor bolts cast in concrete shall conform to ASTM A307 and be placed at 6 feet o.c. and located A with B. Reinforcement shall not be displaced or cut to,provide clearance for penetrations or embedment. - /1 FOT �y 0�> GENERAL REQUIREMENTS e , o LU i ) 1.1 All work, includingmaterials, assemblies,equipment,forms, methods of construction, etc. shall be ZO�it&.J 7,7- 5 1 I[ -• in accordance with all applicable New York State and local codes and zoning ordinances. �f 4� t"fz7/i/!DL f+i IIJ 100 5(OX 1J]"�u; -- 1.2 The contractor shall obi'n all building permits;file all required insurances; and pay all related ken .; $ 5 2�1Y' Y'✓'lIr7JKJ✓ '.�-k1VJ2- hj ,iN �'J] YjD GOhI NI"� ) t' 10._I I�,!.. ilJtl . .. 9P N WiWtiO4� OEf OOd IJ( 1=1�i U.F.lj I-10�I=.,l. /}i/J OG i 11411 KG�E(✓ mth the municipality having jurisdiction. Al F -t ,''j/-tr PAI f 6 - N/}I;i� 1.3 All work is to be performed by those licensed by the Town of Southold and in accordance with all m _ i applicable codes, rules and regulations. CJ r� f4 rf�l•z- i•^ _� "'' — _= NGvJ 2 � .✓ .k« " '': _ G PrhIJ:.. � F�"'�. pP ry '' ' �V • r '� II f�I'°" ��•='L 0'7 G' _ _ 1.4 The contractor is to arrange for all required inspections and obtain approval for each phase before e- I� ( �iRl1f'l�L1T' ':/1 ' - proceeding to the next phase of work PP 9 P ;e'� �Xla .���.�'=. io C'T,� c, P�Niti � g I TABLE R301-212 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE �i 1.5 The contractor is to guarantee all materials, appliances, equipment, installations, workmanship, etc. III �� -_ FOR WOOD STRUCTURAL PANELS°•a•c•d for a period of one year from date of the now Certificate of Occupancy. All manuals, operating Y' Z { FASTENER SPACING r -.. - instructions, manufacturers' warranties, etc. are to be given to the owner. All products and N V Mi 'il'/ 5r 1' liQfJIJE5(; (0i'J P E 4 M m I I III I I I)e 4 toot a toot equipment to be installed in accordance with manufacturer's instructions and rccommendafions. 0 ! q FASTENER Panel span < panel span < panel span �• I d , '- p 'r - - �' �(JNEG i(DIPJ 1.6 The followingpublications shall establish reference standards for quality: Residential Code of New LL U `O rypE 5 4 toot s fi loot s B toot '�''4 I �- P O __ _ 1 'o -27/2' _ Yodl State American Forest and Paper Association Dori Frame Constmdion Manual for One and L - 4�__ L I - '- — c — ' c • d e a-R N' I � s t � L -�/�� !-• lir` - �-. _.__ I. _...- r ._ A� Jul "A",I I c > — �, )ori-, au<' � 5 W04 'S'. LWi 4 -- - 9 C UWIr4K '09 ',,�?rI I�GV-I I.1l�l`AiN ryc%�-� • J� 'AL.JGi� N'�.�7x.1 i7•�;• , ,y , , — — 77 — if Y� b 7*kK � ; - '� c� 'b 41 _ ��• Y I 1C1�9t' LIVIII.: RW1 _ t3i«Ih1'✓s1✓,ITUtF � - \tyo, w( tI� z' Yf• � ' _ l ���F-3��t�'�t, �dk9NI. rti_kl J NP�i sar' ` m r p,l i;.." xGMI TrJhel . 600T3"� i�/�'i A I01i 4 a 'lP19 I� 'IM'�,+'I _ _ - -- -- MAJl1 A N C".K+. A�YIX', V` k 5L6" r- -r — GR /T'_ � j li pp INiECIE7CL.ZJ�JitFla 1 EYK( h1G) r �y • �.lt}� - _. «.`._ _ Il�za � � � '� I A ' I 01 ,r t �, t � - I , IflCr„��; �j -'-- How t n_ -. - �' 1 •lP4 -- NEG:) {��/Ru•F A .._..�... 0.d UA: PLUMBING RISEK D�/ G�Af�i I 14 4 --- � , ZONINGCACULAT,IONS - k,t a �i K NR kjjl LS 1 - - - -- Exrs g tSa t It 150 0 sf Floor Atea !a 1S Pmpose _ --' --- - ' First Floor HouHouse: 1238 sf _ House: ORK +� ' 893 sf ,New Pomh/geck 3004 ' Garage: - 3343sf- 1,538 sf �¢ . sf- 1,53$if =13,967r sf sf 15,Noncoof iil/Ytots . .t1 -- ' . _ . _ . • ' � ` � �LL�� � m�� -I �, - � ' . � �r� La-M Lot area - 1so :. y ��7 ,,1,1 ._'QJ.S Ct�. a°S-13Q _ • , - '� Attu _ -� or ^r yam" Lot wea Building Afea pursuant o Sea. 1 0.244 qL,m Q Propose ____ Proposed-Lot LWamge:' 1�938.St115,,0oolsh .10 N .: 13,• : ,`� - - ., I,- 1,� Building Area/I:at A1ea a awin Lot Covera I y, u1. !t iJk' ("iw+Rmm allowed} O ' XfSP.0 _ RR? u_TO'BE.AL ( P 3 R ,. iN xiLTDhf FROM % sed �,yt�,,,�`'_ ;,. ,' '.,, 7.�3:�IJRQEM ', . ' . .�• 'A , � ., .. , ,,�, .� , _ R� t"�' � 13 _ I Yards'-or�uant tb5dc.+100:2 4 yohconforma r rllots. t, ', ' , ' , . , •; r•t T-y � � � L tAJ ,N F ' yfi' C7f= �' ti• _ _ . .- .r I - � ., �I Stn'ewanscon Front MM�M' H4 31 (atekiapng sWa4ure) Side: 90 , 410' „ : N I �„ ,_ �- : '� �.:_..,..�.,.:,_....,_.�«_—..._ , . ,,,._ . . ., � ; - - ,., 4Jd . . •-:'� ' 6�SG.i' ' Sidai r�� ZS'' , !19.3 - - � . .?',, 77"i" • ♦ i a TIT 1! _ Wall aNtl - - —— • partition r ' e �� - --- ------- -------- Msmw to antl - - 4 be reodpyle o ltbitt�t d L. WMa4ro a3 trod Bottom plat(eM 3217) r' R3gSC i" om plate gattmm Plate (oo,3221Plate 33) '- 7717-7, 1 Co creteilVl�esomy UI1If, FUllylt'IIltrared - F *r ` I Wood Scud Exterior Partiti 4"'1 -"i r fl Plywood sheathing air�tsqtionbnnier Siding to match ewsppg t y Cly c Bad h1p111a6on.bG(W studs, -wan stop 4}�rm_* - �"gypsum board'on**ior *1 1 anchor exit lase3217a3$2.31 ' l ;,,,."� ��y� .Baum Plate �N�/Irll��(p'rJa+ll /J 4 1 steal strap lappaa umer aottom I, ,, ' r - -Wood Stud Exterior Partition at Garage Matolax3.2 1 WYf1flN o GA t 2" X o 161> •with Itrationbarrier;' '� plywood sties ear inp - { - - Siding to thatch existing _ 1: -W Existing Exterior Partition W-k i Iy ? \ rsDGN - IJI I; ` �,. 2" X4"@16" r - •�' 1, � � I N �j I � •� _ ,.._,_, ,.. .-_ ; 'y '. i � Batt insulaWonbetween studs , 1 Bottom Plate Anoh'ora o•to S sb-on-Grade Full height,l/a" foil blocked rigid insulation r gypsum'boprdon`lnterioe 0t� t 009 VIA- our:Wags g One H �� --. _ - _ mrm NewMzah Interior partition, X @ 16 oc ♦`'*., -- �\ One layer 5/8" Firecode Cry `k -` Si' \ c61�IpVq . �� \ � `� � "Board on each side with Ba ,y It uup;01'1 ( � J�., 1 Insulation,betweenst ds 4 rhoight - - I' � � Q { I N� u9S4 - _ New IntenoAParkipoq 2 X 4 @ 18 t y� One layert/2,,,..Gypsum t - - 11..JJ �• - 2X8 �X'°s - BoarSoneecfisi¢e Batt ' At x' 24'Ic. I -�.. Insulation batween stall>full"height . e,w v L'Y',cr. �s•, 'EC C L GEND f' . hard wiled Smoke detector, Switch, '3=way 5witohNN Y XD Dimmer . x +F'' Switch _ t, d - 'x ( '`•. ^/ New Duplex Receptacle >," a �• a • - a .Ji 1 (el t. I'�-- - - -• _-1 . __ _ v riFl New GFf Reeeptacte .. i �1 ,, � �• � � D Telephone Lack �{ d it Cable TV Outlet I 4S I_�u ♦ - Mau awn wan stub O New Ceiling Fixture 'I MI eons antl - ' pettgin Plata i pabor plate Waeham aq Imtl ., � I .9II1 a Archm bolt nchgr pgn;.r 9.21.7) (a F1321:]a 32241 - -nE�O111 K lei t rl at �f � sill plot. Y - SSiteat aatrap .steel Step lapped pntle FOUN'Y7f1TI0N .11N El.EGTKIG�L 1�/�Iy .. . i' lase 3223) f3 (pee 3.2231 7 r 4 oil N sill Plate Anchora$a to.Masonry Foundation Walla �} r 1:� � "� - — — — Vii " ��'t.1��1. ',l�tUa�� 1 � •. ,. �' � I y - . s` 1 i • I II(../M.� U�/'Ll/ 'U.1/7�'i V.nFSG ' :+vim -.� ,,. �`f' 'te •+ry ,I HFhffla=r NYS Energy Code A. All new work shown on these drawings shall conform to the New York State Energy Conservation lite - I Code, Simplified Prescriptive Building Envelope Thermal Component Criteria, non-eledric comfort heating 11 (6,000 heating degree days). FI'wc]srd C'..♦.CrV � 1 — -' FI2r*��7i.ii><.:.i�: - Exterior- nor Walls: . R i8 I 1 � } r (} I l C�-1S INSr➢!-J_tTlfJ �__.__ ,� ' ' - al(`' aY4<I - �'j ` r y , Roof/ceilings. �'R-38* d I , F ' � � ♦.;ht=i_'_ _(�/IA.t7llU-HF�171t1d�; I 2 ul ,lor$(' looms: R-21 , It ..�,, r .'�. p -- —'ZxlO LE3' Crawl Space Walls:. R.20 _ ' I --- ' ----� U/o',MANv.I"i INJD -SILL - � Slab edges: R-9 to 4' below grade `y.>v,' iA Glazing U-0.35 1 � - E�. ti ..NI(Ul:+i *Sec. 602.1.2 'Where the construction technique allows the required R-value of ceili Ei,9•�° Fiume, NSE,• G1G51 �T .' --- 7 } gl_ /u 7=NSU-LAf' _ 19 reg - rl9 insulation to be y' ° r�,��r *�\ • uNr "FY ,FLA-ras - - obtained over the e>ctexor wall top plate,R-30 shall 4e permitted to be used whsre R-384s required." ij x r _ V'�� f' L�iM1 uJS� rtt�tu 0' ' \ti _ Concrete Work ©I ��++ 1 Concrete construction, placement and methods shall conform to The American Concrete Institute +� -1 \ '. standards and specifications.. ♦ . ' 2. Concrete shall have aminimum 28-"day field cured compressive strength of�3,000 psi, maximum 11� . - aggregate size a K". �1,t, 1 „� �J XFjT rvl P� 1 h�d,'S 3, Admixtures containing chloride Salts shall not be used. _ o a! „ - --fj�QE �1S.MQ'4_ /YMRtd4?fatf✓ - 4 yn {. rya Lys,{lT,yl.;;� 4. Concrete shall be "Ready'Mixed Concrete" and shall,conformto ASTM C94, Attimeofplacement, .:114 �RAUEtr l'/y+'MIil�7 concrete shall have a slump of 4" maximum aper ASTM C143}..MateriatsM1Used to produce concrete and 150n thereof shASTMC 33; Water,e otab a elle free of oils 'IIS Lis1y'� rrl.�`_r<113 >iY +`- .. t �., •' testing P�' pPPll danlshsfi: . , ;,, ASTM4 , - itiTJ 1 rr - .' . _ , .^ ^' r \ i_ t iadds, pchananffor Cement- Yrlf4 f y,- lace en lied in ACI -r 1 ! oncrete shall placed cads ll consolidated tune .p r aF. matter. All alkali, anf[,o , - � - - thoroughly 9 manl'us g rotr' . 9 9 P 4 than. 9 g Degrees g. i ,', "I I 5 Concrete when placed shall have a temperature between tees and•Jtl p es F Teltipuafyre of u/ I concrete during mixing or transport shall never b lower '40 de rees'nor higher than 90 pe rids F I-n`-_ ( r r r, + During cold weather mountain concrete at minimum temperatanoof 50 Oagye:as F for 3,days'and above 32 Degrees F for 14 loyal During hot weather-(ambient tmpabave SQ Degrees F) Contiadr shallI ' fakeproper precautions,as required t minimize temperotura:and shrinitage ranking of conerettj. , 6 Design,fabrication; instagation, and removal of txihcrote fomworkero responsibility of Cpaitaslor ti castinconcreteshall " 7. Anchor bd conform to ASTM A307 andbe plated at'6 feet,ox:and,located , '8. within Re nforcomegfshall not be displaced or cut to pievide•dearance.tt penehatibn5 or ehlbedment.' ' c R Z 9 2 Permit Number J REScheck Compliat a Certificate Checked By/Date New York State Energy Conservation Construction Code RES checkSoftware Version 3.5 Release lc Data filename: C:\Program Files\Check\REScheck\Paul Nealon.rck TITLE: Nealon Residence, Interior Renovation&Porch COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric DATE: 04/28/03 DATE OF PLANS: April 17, 2003 PROJECT INFORMATION: D ARS Nealon Residence 450 Bayview Avenue ��5 �OENSTIpF� Southold,NY 11795 Tax Lots: 1000-52-05: Lots 38 and 39 COMPANY INFORMATION: Nq 1'0. 02�1'i® Q� Susan H. Frooks, R.A. 21 Central Drive O'c N Plandome,NY 11030 COMPLIANCE:Passes Maximum UA= 83 Your Home UA=56 32.5%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 320 0.0 38.0 8 Wall 1: Wood Frame, 24"o.c. 432 18.0 0.0 25 Window 1: Vinyl Frame:Double Pane 5 0.500 3 Window 2: Vinyl Frame:Double Pane 4 0.500 2 Door 1: Glass 4 0.500 2 Door 2: Glass 4 0.500 2 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 320 21.0 0.0 14 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief, and professional judgment, such plans or specifications are in compliance with this Code. §uil AI/DelsgnJ Q&c \? . � } ± � � � . �2 �\ =: �. : �< =� . � 4 �. . �\ l\ �\ �\ . �\ �\ �\ � =/ �. �\ �\ .