HomeMy WebLinkAbout48450-Z o'�S11�F8t�coG � Town of Southold 2/14/2023
o� y� P.O.Box 1179
53095 Main Rd
�
01yjj�1 Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 43851 Date: 2/14/2023
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 100 Macdonalds Crossing,Laurel
SCTM#: 473889 Sec/Block/Lot: 145.4-15
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
8/9/2022 pursuant to which Building Permit No. 48450 dated 11/2/2022
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
roof-mounted solar panels to existing single-family dwelling as applied for..
The certificate is issued to Hasday 2020 Family Trt
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 48450 1/11/2023
PLUMBERS CERTIFICATION DATED
0 A rize gnature
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
C3 TOWN CLERK'S OFFICE
C4
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 48450 Date: 111212022
Permission is hereby granted to:
Hasday 2020 Family Trt
200 E 61st St Apt I I FG
New York, NY 10065
To: install roof-mounted solar panels to existing single-family dwelling as applied for with
flood permit.
At premises located at:
100 Macdonalds Crossing, Laurel
SCTM #473889
Sec/Block/Lot# 145.4-15
Pursuant to application dated 8/9/2022 and approved by the Building Inspector.
To expire on 513/2024.
Fees:
SOLAR PANELS $50.00
ELECTRIC $100.00
CO-ALTERATION TO DWELLING $50.00
Flood Permit $100.00
Total: $300.00
Building Inspector
pf SO�j�Ql
0
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 �Q sean.devlina-town.southold.ny.us
Southold,NY 11971-0959
Q�yCOUNTI,�c�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Hasday 2020 Family Trt
Address: 100 Macdonalds Crossing city:Laurel st: NY zip: 11948
Building Permit#: 48450 section: 145 Block: 4 Lot: 15
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: Electrician: Green Logic License No: 43858ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Solar X
Commerical Outdoor X 1st Floor Pool
New X Renovation 2nd Floor Hot Tub
Addition Survey X Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors
Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO
Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors
Disconnect Switches 4'LED Exit Fixtures Sump Pump
Other Equipment: 14.78kW Roof Mounted PV Solar Energy System w/ (18) SPR M415 BLK H AC
Modules, SunPower Monitor, AC Combiner, 80A Disconnect
Notes: Solar
Inspector Signature: !Lz Date: January 11, 2023
S.Devlin-Cert Electrical Compliance Form
OF SOGTyolo � V '✓ �/I G
f # TOWN OF SOUTHOLD BUILDING DE
631-765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION [/_] PRE C/O [ ] RENTAL
REMARKS: �o I a/
DATE INSPECTOR
rsF SOUTyOIo --
# TOWN OF SOUTHOLD BUILDING DEPT.
courm 631-765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] ULATION/CAULKING
[ ] FRAMING /STRAPPING [ FINAL C,�
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS:
ws
u 4/
DATE << �! INSPECTO
J A M E S J. S TOUT A R C H I T E C T & Assoc .
2 GREG LANE E AST NORTHPORT N. Y. 631 - 8 58 9388
Post Installation Letter
December 8, 2022
RE: Hasday Residence
100 Macdonalds Crossing
Laurel, NY 11948
To whom it may concern:
This letter is to confirm that as of this date December 8, 2022, I, James J Stout, NYS
license 021633 have inspected the placement and installation of the roof top solar
panels at the above-mentioned address. The solar panels have been installed as per
manufacturer's guidelines and specifications. The racking system design and
installation complies with the 2020 NYSRC and provisions of ASCE 7-16. The
installation was done as per plan.
Thank you for your cooperation in this matter.
James J. Stout
Architect
ARE° c
0NC3 S �.
021 33
® � � 1UI
JAN 1-- 2023
BUILDING DEPT
�rnniwnc eM mini n
FIELD INSPECTION REPORT DATE COMMENTS
b
FOUNDATION (IST)
C
------------------------------------
FOUNDATION (2ND) t�
z
O
Co
H
ROUGH FRAMING&
PLUMBING
r
t�
INSULATION PER N.Y.
STATE ENERGY CODE S
r
i 7.3 t C
FINAL -
ADDITIONAL COMMENTS
7TD4 AIXU 11 Lfl 12,2—
V66
io
O rn
G
r
b
(v o
z
x
�sx
d
b
H
o�g�fFO t TOWN OF SOUTHOLD–BUILDING DEPARTMENT
y Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959
Telephone 631 765-1802 Fax 631 765-9502 h s//www.southoldtownn ov
y T
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use only
,U
PERMIT NO. Building Inspector: G
Applications and.fornms must be filled out in their entirety.Incomplete Tam's
"pp
a lications vvill;not, ..._.h._
- be._accep-- - -ted. Were.the Applicant;is not:.the owner,an,
Owner's Authorization form'(Page 2)shall be compieied.
Date: g It Zz
OWNERS)OF PROPERTY:.,.
Name: scrM#1000-145-4-15
Project Address:l�Macdonal_ds_Crossing,_Laurel,_NY-1 1948
Phone#: g/7- 7�— �-)g --- -- Email. ( oa/ici-,,ovn/7@J-z4mw/, corms
Mailing Address:
CONTACT,PERSON
Name:Barbara-:GreenLogic LLC
Mailing Address:97 North Sea Road,_Southampton,_NY 11968
Phone#9631--771-5152 x117 _ _ _ Email:BarbaraC)Greenlogic.com
DESIGN PROFESSIONAL INFORMATION:.
Name:
-��-_-=-�av,rit.s .J�S-�-o�,t,._—�c�n�a -�__�� � .so -- _.��e-s---�--- - _----T�_------r-- --
Mailing Addressz_ ✓C _ ___.�.� 0 z �N l 3 �_� r�_�_. --- - Y - ----
I I
Phone#: LP 3 - S2'J 5--0j 3-g-9- - - - Email: (.1J�-0 a-- - -= t.�T�►'c�.._.�-D�►�I
- -
:CONTRACTOR INFORMATION-
Name:GreenLooic
NFORMATION:Name:GreenLogic LLC___
Mailing Address:97 North Sea_Road,.Southampton, NY _11968
Phone#:631-7771_5152 _.. Email:AM@Greenlogic.com
DESCRIPTION OF 011606SEU CONSTRUCTION
❑New Structure ❑Addition DAlteration ❑Repair El Demolition Estimated Cost of Project:
D Other Solar Panels 510 $ 3Z,0�0
Will the lot be re-graded? ❑Yes Fm]No Will excess fill be removed from premises? ❑Yes ONo
1
PROPERTY INFORMATION
Existing use of property• .� Intended use of property:
=c�wr l-1 I - -
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R this property? ❑Yes Bo IF YES, PROVIDE A COPY.
Check Box Affer Reading 71ieownec/contractor/design professional is res a -„
ponsible for all'drainage and storm water Issues as provided by ;
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinanceof the TowwofSouthold,Suffolk;County,New Yorkand other applicable Laws,Ordinances or Regulations,for the construction of buildings, -.—r
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws;ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section'210AS Of the New York State Penal Law.
Application Submitted By(print name):GreenLogic LLC MAuthorized Agent ❑Owner
Signature of Applicant: J A Date
STATE OF NEW YORK)
SS:
COUNTY OF Suffolk )
Nesim Albukrek being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the Contractor
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this `
day of YI JUIN ,20 ?� n
o P is
CASSANDRA L COVELLO
Notary Public State of New York
NO.OIC06399661
PROPERTY OWNER AUTHORIZATION Qualified in Suffolk County
My Commission Expires Oct 28,2023
(Where the applicant is not the owner)
Po 66y ( 63
I, Ly i01L-u reslding-at L_C
do hereby authorize GreenLogic LLC to apply on
my behalf o the Town o South Id Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
�g�}ffCdtk1, BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
- Town Hall Annex- 54375 Main Road - PO Box 1179
Southold, New York 11971-0959
, ,� ,�•� Telephone (631) 765-1802 - FAX (631) 765-9502
' roaerr southoldtownn .gov -- seand6a�southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 8/4/2022
Company Name: GreenLogic LLC
Name: Robert Skypala
License No.: 43858-ME email: Barbara@Greenlogic.com
Phone No: 631-771-5152 ®krequest an email copy of Certificate of Compliance
Address.: 97 North Sea Road Southampton, NY 11968
JOB SITE INFORMATION (All Information Required)
Name: Hasday 2020 Family Trust
Address: 100 Macdonalds Crossing, Laurel, NY 11948
Cross Street:
Phone No.: 917-572-5318
Bldg.Permit#: M30: email: goaliemom17@hotmail.com
Tax Map District: 1000 Section: 145 Block: 4 Lot: 15
BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system
(18) SunPower SPR-M415-BLK-H-AC panels Et (18) Enphase IQ7HS
(1) SunPower PVS6 monitor System Size: 14.780kW
Check All That Apply:
Is job ready for inspection?: DYES ❑✓ NO ❑Rough In ❑✓ Final
Do you need a Temp Certificate?: DYES [—]NO Issued On
Temp Information: (All information required)
Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter#
❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead
# Underground Laterals ❑1 ❑2 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N
Additional Information:
PAYMENT DUE WITH APPLICATION
Electrical Inspection Form 2020.xlsx
BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
Town Hall Annex - 54375 Main Road - PO Box 1179
` Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
rogerr(aDsoutholdtownny gov - seand(aDsoutholdtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 8/4/2022
Company Name: GreenLogic LLC
Name: Robert Skypala
License No.: 43858-ME email: Barbara@Greenlogic.com
Phone No: 631-771-5152 ®krequest an email copy of Certificate of Compliance
Address.: . 97.North Sea Road Southampton, NY 11968
JOB SITE INFORMATION (All Information Required)
Name: Hasday 2020 Family Trust
Address: 100 Macdonalds Crossing, Laurel, NY 11948
Cross Street:
Phone No.: 917-572-5318
Bldg.Permit#: 0 email: goaliemom17@hotmail.com
Tax Map District: 1000 Section: 145 Block: 4 Lot: 15
BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system
(18) SunPower SPR-M415-BLK-H-AC panels Et (18) Enphase IQ7HS
(1) SunPower PVS6 monitor System Size: 14.780kW
Check All That Apply:
Is job ready for inspection?: ❑YES ✓❑NO ❑Rough In ❑✓ Final
Do you need a Temp Fertificate?: DYES ONO Issued On
Temp Information: (All information required)
Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter#
❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead
# Underground Laterals ❑1 02 ❑H Frame[-]Pole Work done on Service? ❑Y ❑N
Additional Information: 1
PAYMENT DUE WITH APPLICATION
Electrical Inspection Form 2020.xlsx I
1
iSUFR
TOWN OF SOUTIIOLD—BUILDING DEPARTMENT
o Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone (631) 765-1802 https•//NNrww.soLitlioldtownnv.gov
Floodplain Development Permit Application
PROPERTY.iN.F061VIAT10NyA Flood Zone: FIRM Panel: SCTM#1000-145-4.-15
Address: 100 Macdonalds Crossing
City:Laurel Zip: 11948
CONTACT PERso'rv : `<<-s Name:GreenLogic LLC - Barbara Casciotta Phone#:631-771-5152 X117
Mailing Address:97 North Sea Road, Southampton, NY 11968
'P�Ro�ECT.oEscRiPTio : Roof mounted solar electric system 14.780kW
ECTION:A.STRUCTURAIDEVELOPMENT.(CHECKACLTHAT:APPLY)
S,
T: �e-ofStiuctuia%'Activit}%;'
-. :•. - e. f:Structure.
T.. . o
Yp,
*Residential (1 to 4 families) ❑New structure
❑ Residential (more than 4 families) ❑ Demolition of existing structure j
❑ Combined use ❑ Replacement of existing structure
❑Non-residential ❑ Relocation of existing structure
❑ Elevated ❑ Addition to existing structure
❑ Flood proofed(attach certification) ❑Alteration to existing structure
❑ Manufactured Home ® Other: Solar Panels
❑ Located on individual lot
❑ Located in manufactured home park
: . : PPLY`:
ELOPMENT. CHECK ALL THAT A
B..OTHER DEV T .....,.)'` '
:SECTION {
❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging
❑ Connection to public utilities or services ❑ Paving ❑ Placement of fill material
❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction
❑ Fence or wall construction ❑ Watercourse alteration (attach description)
❑ Excavation (not related to a structured development) ❑ Other development not listed (specify):
•_..:r. .. '. :...:: - z; • to t{ie)Zest ofm' knowled'e-fh*e information'c'onfa ned ...
Bysigning,below.l 64-terms-an d conditions,of.this,permit and certify. y . g..
in'this application is true and accurate.:.I iiriderstand,that n6 Work may start until a`permit,is"issued:The permif may be'revoked if any
false statements are'made hei ein:If revoked,all,work must;cease:until permifiis'reris'sued.Development shah-not be used or`occupied
ermit will ex'pi no work is;commen'ced`rivthin;oiie year•,of,is"suanc ,Qtti'er pe�ri�itsmay'be:;:.
until.a:Cert:of"Compliance`;is;issued.Thep„ p .,
re"wired to:.fuiflll:re""u'lato" :;re"uirenients'.App}icant gives consent to local autfioi ity or rep"resentative to makereasonable inspectiofis;.
G g ry 9,
to verify complian'ce:; 't
s..
Application Submitted By (print name):GreenLoglc LLC
Signature of Applicant: Date: 11/7/2022
GREENLOGICO
ENERGY
August 4, 2022
Town of Southold
Building Department
Town Hall
53095 Route 25
Southold, NY 11971
Project Info:
Hasday 2020 Family Trust
100 Macdonalds Crossing
Laurel, NY
1000-145-4-15
Dear Building Inspector:
Please find attached a building permit application to install a roof mounted solar photovoltaic(PV)
electric system for the above referenced property.
In connection with this application, please find attached:
• Building Permit application with owner authorization
• Application for Electrical Inspection
• 2 Surveys of the Premises
• 4 Engineer's Reports
• 2 Three Line Electrical Drawings
• 2 Spec. sheets of the solar panels
• 2 Spec. sheets for Racking System
• 2 Spec. sheets for Monitoring System
• GreenLogic Suffolk County Home Improvement License
• GreenLogic Certificate of Liability Insurance
• GreenLogic Certificate of Worker's Compensation Insurance Coverage
• Installation Manager's Master Electrician's License
• Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection)
Please let us know if you need anything else in connection with this application.
Yours truly,
`J3avc,=ac ew cw&
Barbara Casciotta
Account Manager
Barbara@Greenlogic.com
GREENL 6005 v.rrfejl jic.com Tel: 631.771.5152 Fax: 631.771.5156
SOUTHAMPTON ROSLYN HEIGHTS
97 North Sea Rd.,Suite 3 200 S. Service Rd., #106
Southampton, NY 11968 Rosyln Heights, NY 11577
GREENLOGIC° ® M
ENERGY
JAN . .0 2023 ED
BUILDING DEPT.
70 nF cnr QLD
January 6, 2023
The Town of Southold
Building Department
54375 Route 25
P.O. Box 1179
Southold, NY 11971
Project Info:
Building Permit No. 48450
Craig Hasday
100 Macdonalds Crossing
Laurel, NY
To the Building Inspector:
Enclosed please find the Engineer's Certification Letter for the above referenced
address. Can you please close the building permit and send the Certificate of Occupancy
after inspection? Please let me know if you have any questions about the installation.
Sincerely,
53x1 bauac&-m ao tac
Barbara Casciotta
Account Manager
Barbara@Greenlogic.com
631-771-5152 Ext. 117
GREENLOGIC LLC •www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156
SOUTHAMPTON ROSLYN HEIGHTS
97 North Sea Rd., Suite 3 200 S. Service Rd.,#106
Southampton, NY 11968 Rosyln Heights, NY 11577
SURVEY OF
P/0 LOT 12 & LOTS 13 & 14MAP
EDGEMEREFPARK
FILE No. 742 FILED JULY 2. 1931
SITUATE Q
LAUREL
TOWN OF SOUTHOLD
SUFFOLK COUNTY, NEW YORK
S.C. TAX No. 1000-145-04-15
SCALE 1"=20'
JANUARY 10, 2008
di` o o
AREA= 27.196 eq. ft. ^•�j 91x _ oo p ��
(Ta suLKHrAD) 0.624 ac.
lb
sn lb1p
�a
5" '.(�� d"' \.\•'•. '•AD
y. i..�;�, o•Rf
ago m .,
Qk
c
xm
I. 1�1 \xa7
G
�1 xm \ \'qt•
o. \
N !/ ,N `
u
r•lpzo O xm b0.
19.
•ate- :�4� 5 by ^//�� m
REP.WCO N KiMGV[E WRM 11E IaaAY C
mwarac rOR 1111E Sumas A5 601Hf9® Y
m nE Lws Ara N•RRam Na ADOPIEQ 14, —
ral ea use er Txc xDr laac mac uNa FTb
TOTE ASSOONtlN
NOTES.
u 1. ELEVATIONS ARE REFERENCED TO N.G.V.D. 1929 DATUM
EXISTING ELEVATIONS ARE SHOWN THUS:m. P'
• EXISTING CONTOUR LINES ARE SHOWN THUS:————s———N
.� rn - EEa7 naDR
N.Y.S.Ela No.50167 nN. CARA¢FIDOR S
rs - 1aP a eaarAD
m - 9onaW or 9uuOEAn
WWIIO®ALTFWATOM 011 AOOROI BR - BOf1011 Q WNL (]
Nathan Taft Cor +f & -
Lan d Surveyor —",IRan N�Ma1— "
TIE L1xD$UmE1OR9 DA®Sm a9 r
�SVL SXNL MOT BE a0115Da✓ID
ro a A vuD nEE wPr.
fAATG11Ob IA]M'ATro MFIOLH SHNL RUM
arar ro TIE PaEal ROR WIEN TME sumo' -
TNAa SleTge-962tliona-Site PimW- Can0latlan lOAolrt PxrP,M®.Ala ax hs sawF ro 1xc �
mlE mcAMr,mwmanca Amlcr Nm 3
PHONE(671)727-2090 Fax(831)727-1727 m ME
Turox mmutl9ra AIE MOt T0.46'faUaE
OFFrES LOWED AT AWEDIO ADDRESS Q
322 ROANOKE AVENUE INE
c aflmRECORD•
:N E O RIpE13 a WAY
RNMEAD,Neal Yak 11901 RNnheeOg
.ftvB OR&g01-0965 ANO/oR OF If
ANY.NOT 6NOWN ARE NOT GOARIM®. w
EXISTING SERVICE EMERGENCY AC
120/240, 1PIH, 'W" S!'ANIDBY GENERA:,OR
....................................................
KWH ) r
PV SA 1
107
AC--COMBiNER a. L..
I
INV-1
......._......_I........._....
....................I...........
A AC-CMB-1
(PV LOADS ONLY) 200A MAIC
......................
1 OOA 71
L---
INTEGRAL DC/AC
DISCONNECT SWITCH, TYP. 1 iGRb-TIE
INTEGRAL 4-STRING A 8 LINE TAP
DC CIRCUIT COMBINER, TYP. 3KR--1
PV-SA 2 A,
INV-2 .',J
,R-14
I
KR--2 AC DISCONNECT I
f I AC- 1S;-1
"It __F
1 OOA
FTT W.
BKR
L--- �1;: - i i -c/T
NEW EQUIPMENT BKR-4
PV-SA-3 Pm-1
❑ MAIN
EJ ES
.................
III V
V_
SA 4 - L,
\ID E171
V I
N
2 1
13
EI E3
EGG TVP. PV ARRAY T
EXISTING AC PANEL I
; III I EXISTINGi JAN 0 5,202
I,
EGC #6 CU Erfl ED
L4,J L ---------
-
IRREVERSIBLE SPLICE, TYP. BUILDINGDE
TOWIOr-Q-nir"A
NLn
Hasday, Craig REVISIONS
100 MacDonald Crossing 04 GREENLOGIC®
Laurel, NY 11948 G� ENERGY
2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY
1.) INITIAL SUBMITTAL WITH APPLICATION
Page 1 of 3 Drawing No: HSDY-3LD2 Revision: 2 Revised: 12/16/2022
ELECTRICAL LOAD SUMMARY,AC CIRCUITS
STATUS TAG POWER, MAX VOLTAGE RANGE MAX.AC VOLTAGE, NOM.
CURRENT
EXISTING PV-SA-1 3,150 WATTS 211-264 VAC N/A N/A
EXISTING PV-SA-2 6,075 WATTS 211-264 VAC N/A N/A
EXISTING INV-1 3,000 WATTS 211-264 VAC 15 A AC 240 V,AC
EXISTING INV-2 6,000 WATTS 211-264 VAC 25 A AC 240 V,AC
NEW PV-SA-3 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC
NEW PV-SA-4 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC
CONDUCTOR SCHEDULE
TAG TYPE CONDUIT AWG. / EGC
A USE-2/PV/UF 3/4" PVC-40 10 / 6
B THWN-2 3/4" PVC-40 12 / 12
C THWN-2 3/4" PVC-40 10 / 10
D USE-2/PV/UF 3/4" PVC-40 12 / 12
E THWN-2 1-1/2" PVC-40 1 / 6
F THWN-2 1-1/2" PVC-40 1 / 6
G THWN-2 3/4" PVC-40 12 / 12
1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS.
2.) ELECTRICAL CONDUITTO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS.
3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS.
4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM
REVISIONSSo na
Hasday, Craig ,y 0S 3.Sr {,
100 MacDonald Crossing �h�� °� y E E L®G IC®
Laurel, NY 11948 �* ENERGY
' r
2.) AS-BUILT CONFIGURATION 'q °zr�s� a° ELIMINATING THE COST OF ENERGY
1.) INITIAL SUBMITTAL WITH APPLICATION
Pa e 3 of 3 Drawing No: HSDY-3LD2 Revision: 2 Revised: 12/16/2022
EXISTING PV EQUIPMENT& COMPONENT SCHEDULE
TAG DESCRIPTION SPECIFICATION
PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-225-BLK, 2-STRINGS OF 7-MODULES
PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-225-BLK, 3-STRINGS OF 9-MODULES
INV-1 DC/AC INVERTER SUNPOWER SPR-3000M-US
INV-2 DC/AC INVERTER SUNPOWER SPR-6000M-US
BKR-1 CIRCUIT BREAKER, PV-SA-1 (EXISTING) MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A
BKR-1 CIRCUIT BREAKER, PV-SA-1 (EXISTING) MATCH AC COMBINER PANEL BRAND, 2-POLE, 30A
AC-DSC-1 AC DISCONNECT BEAKER, LINE-TAP 250 100 2-POLE, NEMA-1
AC-CMB-1 AC COMBINER PANEL 250V, 100A, NEMA-1, 1-PH, 3-WIRE
NEW PV EQUIPMENT&COMPONENT SCHEDULE
TAG DESCRIPTION SPECIFICATION
PV-SA-3 PHOTOVOLTAIC SUB-ARRAY (NEW) SUNPOWER SPR-M415-BLK-AC, 1-CIRCUIT OF 9-MODULES
PV-SA-4 PHOTOVOLTAIC SUB-ARRAY (NEW) SUNPQWER SPR-M415-BLK-AC, 1-CIRCUIT OF 9-MODULES
BKR-3 CIRCUIT BREAKER, PV-SA-3 (NEW) MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A
BKR-4 CIRCUIT BREAKER, PV-SA-4 (NEW) MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A
PROPOSED EQUIPMENT SPECIFICATIONS
Hasday, Craig REVISIONS fl
100 MacDonald Crossing E E N LOGIC
Laurel, NY 11948 ®
` * ^ ` ENERGY
- - r
1.) NSITIALSUBMIITTALWITHAPPLICATION FIGURATIONORNENyO? ELIMINATING THE COST OF ENERGY
Page 2 of 3 Drawing No: HSDY-3LD2 Revision: 2 Revised: 12/16/2022
9 11 11! 111
J A M E S J. S TOUT .A R C H I T E C T & Assoc.
2 G REG L ANE E AST NORTHP0RTN. Y. 831 — 8 58 9388
�a
Letter of Certification
September 26, 2022 I
FLOOD ZONE
RE: Hasday Residence ;-OMPLY WITH CHAPTER 1146"
100 Macdonalds Crossing 7LOOD DAMAGE PREVENTION
Laurel, NY 11948 SOUTHOLD TOWN CODE.
To whom it may concern: j �ofYj
I4f,(Aj-�kad�'�y' a
I, James J. Stout, registered architect NYS license number 021633 would like to
submit the following. I have inspected and analyzed the roof structure at the above
listed address and have determined the structure and the attachment to be adequate
to support the new additional load imposed by the proposed solar system and
complies with the 140-mph wind design load as per 2020 Residential code of NYS
(RCNYS), 2020 Energy conservation construction code of NYS (ECCCNYS), and the
ASCE 7-16.
The 2"x 6"@ 16"o.c roof rafters will provide the required support. The existing roof
has 1 layer of shingles on 15#building paper on W" plywood sheathing.
APPP VED AS NOTED
James J.Stout DATE: 2 B.P.#
Architect FEE: LO BY:--JQIL—
,)CCUPANCY OR NOTIFY BUILDING DEPARTMENT AT
765-1802 8 Asti 1-1 0 4 PM FOR THE
IS c U, IL ,IAI E II FOLLOWING INSPECTIONS:
J `+ YY V l� 1. FOUNDATION - TWO REQUIRED
T ^ FOR POURED CONCRETE
NI
TOUT E,RPICAT;. C�N��E-� sTctiiT ROUGH - FRAMING & PLUMBING
IF CCU `NCY 'r � F' SULATION
4. NAL - CONSTF;UC-ION MUST
_ COMPLETE 0.
C NSTRUCTIGN SMALL MEET THE
COMPLY WITH ALL CODES O
fi ,o R EMENTS OF THE CODES OF NEW
NEW ORK TOTE & TOWN COD 0RK STATE. NOT RESPONSIBLE FOR
AS E U1RE ND CONDITIONS *OF NE�� ESIGN OR CONSTRUCTION ERRORS.
c j
6 I j- L,rI IAC BOARD
_� TONJNTRUSTEES ELECTRICAL
INSPECTION REQUIRED
GREENL®GIC®
ENERGY
Greenlogic,LLC Approved
Hasday,Craig
100 MacDonalds Crossing
Laurel,NY 11948
Surface#A:
Total System Size:7.470kW
1 circuit of 10 on a 20A breaker
1 circuit of 8 on a 20A breaker
Azimuth:220°
Pitch:20°
Monitoring System:
❑ ❑ ❑ ❑ SunPower
Panel/Array Specifications:
Panel:SPR-M415-BLK-H-AC
Racking:SunPower Invisimount
Panel:73.7"X 40.6"
Array:30'11 1/2"X 13'8 5/8"
Surface:43'1"X 17'1"
Magic#:Invisimount
Legend:
® 18 Sun Power 415W Panels
® SunPower Invisimount Rail
• 52 Quick Mount E Lag
8 2x6"Douglas Fir Rafter 16"O.C.
Notes:
Number of Roof Layers:1
Height above Roof Surface:4"
Materials Used:Quick Mount,SunPower
Added Roof load of PV System:2.31 psf
Engineer/Architect Seal:
'` EDARC'�i
SESJ S To I
JLAUG Q - 2072LI
BUILDING DEP,'
Drawn By:D Drawing#1 of 5
TOWN OF SOUTH Date:07/07/2022 1 REV:A
Drawing Scale:3/16"=1.0'
GREENL®GIC®
ENERGY
Green Logic,LLC Approved
Hasday,Craig
100 MacDonalds Crossing
Laurel,NY 11948
Surface#A:
Total System Size:7.470kW
1 circuit of 10 on a 20A breaker
1 circuit of 8 on a 20A breaker
Azimuth:220"
Pitch:20"
Monitoring System:
SunPower
Panel/Array Specifications:
Panel:SPR-M415-BLK-H-AC
Racking:SunPower Invisimount
Panel:73.7"X 40.6"
---U6;� Ul Array:30'11 1/2"X 13'8 5/8"
Surface:43'1"X 17'1"
Magic#:Invisimount
Legend:
® 18 SunPower415W Panels
® SunPower Invisimount Rail
• 52 Quick Mount E Lag
24"Douglas Fir Rafter 16"G.C.
Notes:
Number of Roof Layers:1
Height above Roof Surface:4"
Materials Used:Quick Mount,SunPower
Added Roof load of PV System:2.31 psf
Engineer/Architect Seal:
,��RED A%
S S
. q!
pq i
r.FLL_ s.
�q 163
i0 N E�
Drawn By:DF -1115-a
cawing#2 of 5
Date:07/07/2022 REV:A
Drawing Scale:3/16"=1.0'
-&GREENLOGIC®
ENERGY
GreenLogic,LLC Approved
Hasday,Craig
100 MacDonalds Crossing
Laurel,NY 11948
Surface#A:
Total System Size:7.470kW
1 circuit of 10 on a 20A breaker
1 circuit of 8 on a 20A breaker
Azimuth:220°
Pitch:20"
Monitoring System:
❑ ❑ SunPower
Panel/Array Specifications:
Panel:SPR-M415-BLK-H-AC
Racking:SunPower Invisimount
1 Panel:73.7"X 40.6"
Array:30'11 1/2"X 13'8 5/8"
Surface:43'1"X 17'1"
Magic#:Invisimount
Legend:
1
® 18 SunPower 415W Panels
® SunPower Invisimount Rail
• 52 Quick Mount E Lag
2 8 2x6"Douglas Fir Rafter 16"O.C.
Notes:
Number of Roof Layers:1
2 Height above Roof Surface:4"
Materials Used:Quick Mount,SunPower
Added Roof load of PV System:2.31 psf
Engineer/Architect Seal:
.� GRED Apc
S j Sro y%
T 021
r N E�
Drawn By:DF Drawing#3 of 5
Date:07/07/2022 REV:A
Drawing Scale:3/16"=1.0'
�� q\
-��. 'L�
'�.-..•
z
_:,+o
No Vent Pipes Will Be Covered By The Solar ArrayG�GREENL®GIC°
ENERGY
Legend: GreenLogic,LLC Approved
Hasday,Craig
AR-Access Roof AP-Access pathway,36" minimum width SVO—Setback at ridge 100 MacDonalds Crossing
per R202 definitions per R324.6.1 as per R324.6.2.1 Laurel,NY 11948
Total System Size:7.470kW
1 circuit of 10 on a 20A breaker
1 circuit of 8 on a 20A breaker
I I
Azimuth:220°
Monitoring System:
SunPower
Panel/Array Specifications:
t Panel:SPR-M415-BLK-H-AC
t Racking:SunPower Invisimount
0 t Panel:73.7"X 40.6"
t Magic#.Invisimount
O -
_ Legend:
Meter _ I ; ® 18 Sun Power 415W Panels
SunPower Invisimount Rail
• 52 Quick Mount E Lag
"t " ,l B B 2x6"Douglas Fir Rafter 16"O.C.
Notes:
gyn
;_,i r. Number of Roof Layers:1
L.__ ��o Existing Array
[�— �-p ———-L} -� Height above Roof Surface:4"
Materials Used:Quick Mount,SunPower
Added Roof load of PV System:2.31 psf
= Engineer/Architect Seal:
J
18 SunPower 415W
Panels \ NE`N
Drawn By:DF '11Drawing#4 of 5
Date:07/07/2022 1REV:A
Drawing Scale:1/16"= 1.0'
-G�GREENL®GIC®
ENERGY
Green Logic,LLC Approved
Hasday,Craig
100 MacDonalds Crossing
Laurel,NY 11948
Total System Size:7.470kW
1 circuit of 10 on a 20A breaker
1 circuit of 8 on a 20A breaker
Azimuth:220°
10B MATERIAL LIST Monitoring System:
-- SunPower
Panel/Array Specifications:
Panel:SPR-M415-BLK-H-AC
Racking:SunPower Invisimount
Panel:73.7"X 40.6^
• Magic#:Invisimount
Material List tai. Rail Material List W.. Legend:
® 18 SunPower 415W Panels
® SunPower Invisimount Rail
Cast Aluminum Mounting Block w/Black Aluminum Flashing 52 • 52 Quids Mount ELag
5/16"x7/9'EPDMSeal ing Plug - 52 - - --- - Douglas Rafter 16"O.C.
2 6" Fir
5/16"65"Hex-Head Lag Screw 52 Notes:
- -- —
Number of Roof Layers.1
5/16„x1.25„FenderWasher 52 j Height above Roof surface:4”
Materials Used:Quids Mount,SunPower
e o 0 e
Added Roof ad o I f PV System:2.31 psf
Engineer/Architect Seal:
— -
_
TCG
�-
a�
1
92 633 �0�
F N ON
Drawn By:D _ Drawing#5 of 5
Date:07/07/2022 REV:A
Drawing Scale:1/16"=1.0'
SUNP WE R°
425-410 W Residential Black AC Module
SunPower"Maxeon"Technology
Built specifically for use with the SunPower EquinoxO' system,the only fully
integrated solution designed, engineered, and warranted by one company.
Highest Power Density Available
The patented, solid-copper foundation Maxeon Gen 6 cell is over
5% larger than prior generations, delivering the highest-efficiency
all-black AC solar module available?
Part of the SunPower. I °
Equinox' Solar System ..
E _
Seamless aesthetics
large
®Compatible with mySunPower
monitoring.
f_ .
} F
U
jHighest Lifetime Energy and Savings
. kirjF_;�.tDesigned to deliver 60% more energy over 25 years in
" real-world conditions like partial shade and high temperatures.2
, _
=es ... .... .... .... _.. ..... ._. .... _ ...
Factory-integrated,"
IDL
Upto
Microinverter /�^
V J''.
iv1b.,
r
A Highest-power integrated
AC module in solar
•Engineered and calibrated.
by SunPower for SunPower
% Years of C;perntion
AC modules
Best Reliability,Best Warranty
With more than 42.6 million and 15 GW of modules deployed
around the world, SunPower technology is proven to last.That's
why we stand behind our module and microinverter with the
industry's best 25-year Combined Power and Product Warranty,
including the highest Power Warranty in solar.
s.
M425-BLK M415-BLK ( M410-BLK SunPower Residential Black AC Module
Inverter Model:Type H(Enphase IQ7HS) @240 VAC @208 VAC
Max.Continuous Output Power(VA) 384 369
_.-.._.._................................._.._........._ -........_....................._.----
Nom.(L-L)Voltage/Range'(,)
240/211 '7.64 208,1183-229
Max.Continuous Output Current(A) 1.60 1.77
Max.Units per 20 A(L-L)Branch Circuit'! 10 9
CEC Weighted Efficency 97.096 J 96.5%
Nom.Frequency 60 Hz 60 Hz
Extended Frequel Range 47-68 Hz 47-68 Hz
AC Short Circuit Fault Current Over 3 Cycles 4.82 A 4.82 A
- ... .._...-........ ......_..._.._............- -- --
Overvoltage Class AC Port III III
AC Port Backfeed Current 18 mA 18 mA
Power Factor Setting 1.0 1.0
Power Factor(adjustable) 0.85(inductive)/0.85(capacitive) 0 85(inductive)/0.85(capacitive)
•s 0. ® e o
SPR-M425-BLK-H-AC SPR-M415-BLK-H-AC SPR-M410-BLK-H-AC ••25-year limited power Warranb,<
Warran:l
Nom.Power(Pnom)W'•! 425 415 410 es 25-year limited product 1,varranty
-
Power Tolerance +5/-01/0 +5/-0% +5/-0% UL'174'I/IEEE-1547
UL 1741 AC Module
Module Efficiency 22.090 21.S% 21.2% UL 61730(Type 2 fire rated)
Temp.Coef.(Power) -0.29%,'°C -0.2995/°C -0.29%/°C UL 62109-1/IEC 62109-2
-- - FCC Part 15 Class B
Shade Tolerance Integrated module-level max.power point tracking ICES-0003 Class B
CAN/CSA-C22.2 NO.107.1-01
CA Rule 21(UI.1741 SA)s
Certfications (includes Vol(Nar and Reactive Power Priority) I
UL Listed PV Rapid Shutdown Equip
Operating Temp.
and ment'
--- ---- I Compliar:ce Enables installation in accordance with
Max.Ambient Temp. 122°F(50°C) NEC 690.6(AC module)
Max.Test Load' Wind:12.5 psf,6000 Pa,611 kg/rn2 back NEC 690.12 Rapid Shutdown(ins:de and outside the
Snow:187 psf,9000 Pa,917 kg/m2 front array)
Wind 75 psf,3600 Pa,367 kg/m2 bath NEC 690.15 AC Connectors,690.3YA)-(E)(i)
Max.Design Load Snow:125 psf,5400 Pa,550 kg/m2 front
When used with AC module Q Cables and accessories:
Impact Resistance I inch(25 mm)diameter hail at 52 mph(2.3 m/s) (UL 6703 and UL 2238),
Rated for load break disconnect
®. PID Test 1000 V:IEC 62804
Solar Cells 66 Maxeon Gen 6
Front:Glass I sigh-transmission tempered glass with anti-reflective coating
Environmental Ratin- Outdoor rated j Modules per pallet 25
i ....-------............................_........ --._..._.._.
Frame Class 1 back anodized(highest A\F 1A rating) i Packaging box dimensions 75.4 x 42 2 x 48 0 in.(19!5 x 1072 x 1220 mm)
Weight 48 lbs(21.8 kg) Pallet gross weight 1300 Ib(590 kg)
Recommended Max. Pallets per container 32
Module Soacing 1.3:n.(33 chin) Net weight per container 18,880 kg
73.7 in
t Based on datasheet review of'websites of top 20 manufacturers per INS,as of July 2021. + (18,2 ril- FRAME PROFILE
2 Maxeon 435 W,22 545 efficient,compared to a Conventional Panel on same-saed arrays(300W i 945 efficient,
approx.1.6 m2),7.9%more energy per watt(based on PVSys[pan hies for avg.US climate).0 Silt/yr slower
degradation rate(Jordan,et.al."Robust PV Degradation Methodology and Apo icadon"PVSC 2018). Groundin les
3 Based on search of datasheet values from n:ebsites of top 10 manufactures per IHS,as efjune 2021.
4 Limits may vary.Refer to local require!nents to define the rUrnber of m croinverters per branch in your area.
.. Y ».......A.
5 Factoryset to!EEE 1547@-20'4 default settings.CA Rule 2.1 default settings prof le set during commissioning. ,o N
6 Standard*1 est Conditions(1000 W/m=irradiance,AM 1.5,25'C).NI DC•;oltage s fully contained within the module. ' ma ""
7 UL listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12.and C22.i-20!5 Rule 64-218 Racid (Aj Long Side:1.3 in(32 rpm)
Shutdown of PV Systems,for AC and DC conductors,vvhen installeo acco,ding to manufacturer's instructions. 51-ort Side:0.9 in(24mm)
E Please read the safer,,and installation instructions for more information:regarding load ratings and
mounting configurations. t I
See v✓masunpowermmicompany for more reference information. Please read the safety and installation instructors for deta:is
For more details,see extended datasheet'vaaw.sunpewer.rpm/solar-resources.
Specifications included in this datasheet are subject to change without notice. coeeue
vrxi°:ury
02022 SunPower Corporation.A.I rights reserved.SUNPOWER,the SUNPOWER bgo and EQUINOX are 544400 RevA
registered trademarks of SunPower Corporation in the U.S.MAXEON is a registered trzdemark of Maxeon Solar LISTED ea�euo
Technologies,Ltd.For more information visit wana•.rnaxeon.o?rnAegal. M.&Ii e,�r°,r°, -Type 2 January 2022
i'�s
13
CCMM p;g ,fin ,e:�� "f•�
�w
Simple and Fast lnstallatio _.....
lrteg-O
'ied module-To-rail ground ng
Pre-„ssQ:ml�lerl mid arir..end c'arnras
Lev!ating rnld camp,for eases)placernent
? i 03 :O! 5"�:,aW^'�+.'l�,.s,::....r-xte.. e»�`ka'...•"'',N
`
Mid:-1a?'" ii• I'JG';.l �r"1;"IIIi.r,IF.S i,:�n,iil .lt,el, .l �w:x"="��=^-^ �`•'� ,�.,_ •,�
Simple,p,e-('rill,.,d ail s,-lkx,
21 o.'Listed:ni.eg ralod gr(x.rn,r4
FIeXIbI(-_y Design
Addresses -
Addresses netarly all slope res:clerciai roofs
t<.
g«.
• Design it landscape and porl.,ai
F:o!i5 t'?ct:le es31)i 0;:)Stacl(2 nianagerren. a.R
Customer..T referred Aesthetics
. module and t-" mounting aesthetics
E�est it class system aesthetics Elegant Sime-)licity
Premium ovv-profile design
SunPoweOl InvisillountT”. is a SunPower-designed
ned
Rack anodized components g
Hidden and clamps and end camps rail-based mot.anting sysr.en The InvisiMOt.ant system
and capped,flush rails
add7"P..S ses 'eSIdP..ntla' sloped roori5 c'a^d COmi;inPS 'c35te
Part of Superior System , ., -'
Instaliatc_in tin�acl, desa: ra flexibility, grad st.aperior aesthetics.
B�?ilt ror use with Sunr)o'o er 17C and AC modules
(I"7 E' Ir1VISIMt1t.Jnt: produci:was specifically envisioned Land
fest-in-class s ,�ysrerelianility and ap sthenic
.'Omoine w:t l`unPotler modules,and engineered to pair-with SunPower C-f1ocl les. The resulting
monitorirg app. systern-level approach will arnplify the aesthetic and
installation benefits for beth homeowners and installers.
Ufa. .. �....£..
;.� sunpower.com
NADH 90S60S#]ua ujmoQ ai:Ju:imp: z)3, cigrs as rausE»vp s!qi ui p,pnjlul suoi;ekuc+ac,s
UJp:".l&',•>.(;ilii!i; '1 Wo:dO�A;Jdd>aa alatjk Iq n„,..�iW!J v_p ai:?S,{JO�ilai)L'a»ac)�ko iN 't[.iyBailLJJ.,:J JE„ne<j:;n;;j0 skaJ'w:njir!k
t)miJ'Sii?JJ io Sk;BW��✓YJt d.2.1(�.;it)�i51ARiµae a3o1 t1�:r:�.J_hl€S- •?'._,.t,;c�i'Jtls 'Pv<�.�_sa�sluai;;ilt�! 'urikeaod€u;;aornouu:�s<:;u .�
'�;jjjge;odo.,o;m<,;;;y;,,Atj J':;<.o gnk.=a. kunoj jfs!.+.ui
............................................--'-....._................_.._.............._.................._....................................................................._....._..._.............._...._............_................ ,......._..............................._.._.._..........._......_......__.._....... _........................
.bre uauJ.^:,c; s•Jl.i'i'7f_inuPUJ ^rhn;>Je Juaulll7 iJ£'joo;CJ.f. b;i lFfnl.af.74.-tri co f at,E{_i;JO,c)eJA@j:.q les:an;:u[1
1i.IdU.IU)[J7G/!')Q:_J 01: ]F>,_puP 17<3).Adl }
:,oz;• yr, tt, :ePa^; l;Onc.ill:iCl\f
'''..v s pas».dj4 w• t9 m:� t"li�t3 w :::3:•' '_' iU,3u fl.)L'7JN`�',:i�l',;)n:J r)n�,'sln1 i:UC
��:.:. :�s.a;�`,t:t�.,...�,.k: l^•k $...Car, i4”^�§�triQ'xu�url:•.aef`g: ,:.,.^„
au.
=iJJ :elN Jc a gU:U:GGI' llCi�'
--......._.......-...................._..........__........._................................. ..
! �...... ...H:k.Em..::e;' m:,. ,��yq�€�wlt•)�', °a s'.°5�;�'e?�sffi,r��;I�.�Ay., ..._ ._,,,.�.
a_
c'ic b SSE';' ...e...,+^'.:,�aa•:.:...., <: j�•,ssy;.e�,��t;�iw'w•..., tq�x�y
.pry) � °da,"��'A,,"�'t�,���. .l:d•�r.��` d� ^.:::...•^ A� ", K«�� .. w>h��w��.:�.`��,.?a'=
............................ ....... .................. ..._.......................
,
(�` r_'U.`•t U I .auafpJdoo iU•1Od)Ici,) -wlsl dc*.)pua
.......................-_ . ..................- ._........._..._.._ .._.._
:lJUF.0 e;•:\';x;11) ".r .._f,'i)�v.s•) 1!%i's j`)0 {
aea
....c_... ..... ..
Fsn :hJ�.o,a Je'd-'_q.:I I i}�-CN) 410€.k:ass',
x
Jenn'i npr;a;i 1n ;<SZ (aJ, o C;).,(;;'0>:' S! SCC9;n;If,eunup.0€qti+ a.-colas Ilei
. w, {I )!)l9 IIF'
�,
....................__...._..... ,
JLI c'LcCGS,x611P uu;uju:r?Ie l(,r,:;.>
........................-...._. _...........__.................................
.........
...................
.................................:.-— — ---
...-........... ......... ... _.
nb 'r"�z`a 1,0 l`;I�y-:,sar STOW!S a;;!�o r:;E>,3... auJ;l_)..PIIrV
a_ac.J!rr,olJ e,. ()r)r)r' ,` -.-................'.".....................................:......
lJidr:E,; UJB 1,P -; - ---- --
...............
_...._-....__ .. nl a;;a• IPua'Jei^•! tuauocl:u0,)
J: cl e)7: G'1>-) OEi o; .!it o nJP..ol.ua.1.
:>1.:�> ..N•�� ira r:• :�A:. ..:z: �'i ga,. .:::?•.: .ecce.:. � "•.ui'Ncc^s.• .,g z�'i�r` :y'r•1��:^a^fes _� � __s••�...�,.�„
�';z �.�.��? �._.^_;tj_•?:,,.�".�17i�"��€,�;I�t '�?'�s';�t„ =.?r.it:= :. ii�"?�<.,., 's �a �.,€�r� �'i.:(>_ ;"y,y,�;,.:G"��.r;,i
. t•tn
. ..<c a '•.. •.<g<..:...... .. . .�....:.x..n.:a.a a••t�•.� tr a:: .,�.,_a...
C12)Pu'_J Algw,asssy-arl p:;nbr; a:qJ5 i'211:11�;le;. UJJcI 1 UU"i Gale'.P! J
o ,.,.......<o......____,__ ......_.._._.- ...._... .. ........._.(�a^.,.•,.•,.i �i'9 U;1W ^.Bf�tiuoN!��}�€111';N nii r ,
I e
c .
4,
L.:.: _
I:^21 Pu : II�p(3 i x.c ln,, j qlP::e dtuel.]P4N?ftil-11001,14
WOWC M,
No
,
AMR
e �
� r�?,. •�t� wr;t',:., yiryi•'k'r.°l•'<K'.'r,.::...•. ;A. :•tea 5:•3...,, .. •m3e
.< ...:mow.,,,,,,a....... .......h,,..,,.....,.,,.....,<...aCe�sY.......,we ,,..-.x....,..; A,.,.....�.,.......... .....Y,...w....k.m��,....,,»�..�......iXd:,Y,..a:..wrxdm,.Ma. ....,<
e ..
L ,
-4r•.
'tea°:w- Y "^ ... <.:•x_=e:�`YLa
zz
""�;.<;:
sT--�„.a. w�.•,, sd � 9,'✓' ... .. s. p.RRt nrc+h` '. •e -". �� �
if, e
Improve Support,
Reduce Maintenance Costs SunPo?wer Energyl-ink—Plug-and-Play Installation
An int,uitve monitoringvtebsilLe enaglcs you to:
This COr7?pl-te SOIIai70n for re5usentiai and conTrneraal mon:'-orr'g and
See it visual rnaip Of CL:sc.or'mer slteb control incU.de,. 'te uF'cv,, r":ti 'v S;..11:t-rysor-6(PbS{.'))which improves
�ernctel'v rna age hunch eds o}sK'es L'ie installadon process,Overall system reliability,and CUStornC"1'
iE C,lve elecdve System reports
E'XpE'r'i-r'IC(
L.oCiitE Sys tT1(S5 10' ct"d reryiol-ely(lad;r':Usk Cornpac-t 0otprint for improved aesLheLics
Diagnose issues or`.ine Robust.Cloud CE nnecti icy and cort'prehensive laical tonne;rlvirV
Drill dovvni for the status(:)` nd viduai device; Flexible configuration of devices during Installation
„.#r ,•. ,Ay, consumption metering
M_
R-venE.i--graoe produc?:Ion!net:-ring(pending)
Web-based commissioning
Remote diagnostics of FVS6 an,,]inverters
Durable UL Type^R Enclosure reduces maintenance dosis
e r
"f
Easy Integration with SunPower eBOS
Add Value for Customers
Robust Cloud Connectivity
With the SunPci',.•ver M niton ing System
customers can: h:'iE.;lt.iple options to rnaintain optirnal
See what their solar s'ystern produces each connectivity:
day,month,or year Hardwires Ethernet
Or�urnize,heir solar nvestryierill and save or? Wi-Fi
energy expenses
` i) Cellular backup
See their ene- use and estimated bill savings
See their solar EvsterT's peforrnance using the
Sunf,o-wer rnonitoring v.rebsite or mobile app ij
;
;y
141
LL
aq.
&„R
L-
kt eq
ny
:• x
I 7 •�
i 5
SunPower Monitoring Websites PVSri SunPower AC Modules
.'IIH 1111 t1 A� 0�lI1 W� �I " i � ]� •I
gyp[ �.... •>•.
w° Multiple communication options include
Ethernet,Wi-Fi,and cellular.
.. - t?M xr •'' � ' � to � '�,. �i �€> �=,zm:.. ?',�:'_ _ �,sy.. �$ 4�.a a�::T7;::.y�.,�;a G�`/7.
Number of SunPower AC rnodules 85 Temperature -221T to {1»G°F{-30°C[o+-60°C
supported per Fi'Sfi F'lumrdrty(maximum) 95%,nor-conbensin;
Intr:.rret access High-speed internet accessva accessible
router or switch
• 100-240 VAC:.(i..-N),50 or 60 F3z
• _08 JAS(L-L I.t 33-phase,,. 60 ht •,,. .,,; �,.�,�
r;
RS-/-5 inverters and meters
. One channel of revenue-grade production rnetering
v:.v.' _ ,..3..f.:f::a.ax.•..,�e'.'�,;....., #+„��-:.", s„��=� :5:' �..�:. la,R;,Afi�r.:�.-.��:,�'„r` to. o-
�
integrated v • E`sRochanr�isOfCOnS!rtinnTet?Yins
Weight g V theniet LAN,or opt!onal`IVAN)port
Dimensions .1.8 x 8,0 x 4.2 in.(30.5 x 2.0.5 x 10.8 crn) PLC PLC for SunPower AC rnoduies
Enclosure rating UL50E Type 3P,
VJi-Fi 802,11 big/n 2.4 GHz and 5 GHz
_...._.._........................-....._.................._.............................................,::_..._............................. .----...__.
Cellular LTF..Ca,..^v 1/:3(:,t!M IS
Data.
rata Storage oL'days
Customer site rrtr rito_.us si�rr��n r�arn _.........--'--'--........._...----..._......................_...._.._.._....--.................... _..__.....__.........................----
- c --
;lpgrade;; A;�orr1atic tirrnvrare ur)gra;e�;
Partner site Pj"Smgrntus sunoow.er.com
3ro:rsers Firefox,Safari,and Chrome
Mr,obile devices iPhone'-,iPad1%,and Ai idroio'”,
Customer app :o ' (,, '.,..m:P' M
1.Create accoun r::ine at:monitor s.sunTr r.e corn. (" . :.w 2X ,'e
0111
n it `as
2.On a moble clevice,:iownload ri re:SunPower Monitor' ? `vJarranty V a 10 year Limited Warranty
app from Apple App Stores"or Google Playlstore.
3.Sign in usir:g account email and password. Certifications UL,WL,CE,UL 61010-1 and-2.FCC Fart 1 i{Class i3)
C u` us
LMTM
FCC ID:YAW529027 E503346
p� e