Loading...
HomeMy WebLinkAbout48450-Z o'�S11�F8t�coG � Town of Southold 2/14/2023 o� y� P.O.Box 1179 53095 Main Rd � 01yjj�1 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43851 Date: 2/14/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 100 Macdonalds Crossing,Laurel SCTM#: 473889 Sec/Block/Lot: 145.4-15 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/9/2022 pursuant to which Building Permit No. 48450 dated 11/2/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for.. The certificate is issued to Hasday 2020 Family Trt of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48450 1/11/2023 PLUMBERS CERTIFICATION DATED 0 A rize gnature TOWN OF SOUTHOLD BUILDING DEPARTMENT C3 TOWN CLERK'S OFFICE C4 SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48450 Date: 111212022 Permission is hereby granted to: Hasday 2020 Family Trt 200 E 61st St Apt I I FG New York, NY 10065 To: install roof-mounted solar panels to existing single-family dwelling as applied for with flood permit. At premises located at: 100 Macdonalds Crossing, Laurel SCTM #473889 Sec/Block/Lot# 145.4-15 Pursuant to application dated 8/9/2022 and approved by the Building Inspector. To expire on 513/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Flood Permit $100.00 Total: $300.00 Building Inspector pf SO�j�Ql 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlina-town.southold.ny.us Southold,NY 11971-0959 Q�yCOUNTI,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Hasday 2020 Family Trt Address: 100 Macdonalds Crossing city:Laurel st: NY zip: 11948 Building Permit#: 48450 section: 145 Block: 4 Lot: 15 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Green Logic License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 14.78kW Roof Mounted PV Solar Energy System w/ (18) SPR M415 BLK H AC Modules, SunPower Monitor, AC Combiner, 80A Disconnect Notes: Solar Inspector Signature: !Lz Date: January 11, 2023 S.Devlin-Cert Electrical Compliance Form OF SOGTyolo � V '✓ �/I G f # TOWN OF SOUTHOLD BUILDING DE 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [/_] PRE C/O [ ] RENTAL REMARKS: �o I a/ DATE INSPECTOR rsF SOUTyOIo -- # TOWN OF SOUTHOLD BUILDING DEPT. courm 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL C,� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ws u 4/ DATE << �! INSPECTO J A M E S J. S TOUT A R C H I T E C T & Assoc . 2 GREG LANE E AST NORTHPORT N. Y. 631 - 8 58 9388 Post Installation Letter December 8, 2022 RE: Hasday Residence 100 Macdonalds Crossing Laurel, NY 11948 To whom it may concern: This letter is to confirm that as of this date December 8, 2022, I, James J Stout, NYS license 021633 have inspected the placement and installation of the roof top solar panels at the above-mentioned address. The solar panels have been installed as per manufacturer's guidelines and specifications. The racking system design and installation complies with the 2020 NYSRC and provisions of ASCE 7-16. The installation was done as per plan. Thank you for your cooperation in this matter. James J. Stout Architect ARE° c 0NC3 S �. 021 33 ® � � 1UI JAN 1-- 2023 BUILDING DEPT �rnniwnc eM mini n FIELD INSPECTION REPORT DATE COMMENTS b FOUNDATION (IST) C ------------------------------------ FOUNDATION (2ND) t� z O Co H ROUGH FRAMING& PLUMBING r t� INSULATION PER N.Y. STATE ENERGY CODE S r i 7.3 t C FINAL - ADDITIONAL COMMENTS 7TD4 AIXU 11 Lfl 12,2— V66 io O rn G r b (v o z x �sx d b H o�g�fFO t TOWN OF SOUTHOLD–BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone 631 765-1802 Fax 631 765-9502 h s//www.southoldtownn ov y T Date Received APPLICATION FOR BUILDING PERMIT For Office Use only ,U PERMIT NO. Building Inspector: G Applications and.fornms must be filled out in their entirety.Incomplete Tam's "pp a lications vvill;not, ..._.h._ - be._accep-- - -ted. Were.the Applicant;is not:.the owner,an, Owner's Authorization form'(Page 2)shall be compieied. Date: g It Zz OWNERS)OF PROPERTY:.,. Name: scrM#1000-145-4-15 Project Address:l�Macdonal_ds_Crossing,_Laurel,_NY-1 1948 Phone#: g/7- 7�— �-)g --- -- Email. ( oa/ici-,,ovn/7@J-z4mw/, corms Mailing Address: CONTACT,PERSON Name:Barbara-:GreenLogic LLC Mailing Address:97 North Sea Road,_Southampton,_NY 11968 Phone#9631--771-5152 x117 _ _ _ Email:BarbaraC)Greenlogic.com DESIGN PROFESSIONAL INFORMATION:. Name: -��-_-=-�av,rit.s .J�S-�-o�,t,._—�c�n�a -�__�� � .so -- _.��e-s---�--- - _----T�_------r-- -- Mailing Addressz_ ✓C _ ___.�.� 0 z �N l 3 �_� r�_�_. --- - Y - ---- I I Phone#: LP 3 - S2'J 5--0j 3-g-9- - - - Email: (.1J�-0 a-- - -= t.�T�►'c�.._.�-D�►�I - - :CONTRACTOR INFORMATION- Name:GreenLooic NFORMATION:Name:GreenLogic LLC___ Mailing Address:97 North Sea_Road,.Southampton, NY _11968 Phone#:631-7771_5152 _.. Email:AM@Greenlogic.com DESCRIPTION OF 011606SEU CONSTRUCTION ❑New Structure ❑Addition DAlteration ❑Repair El Demolition Estimated Cost of Project: D Other Solar Panels 510 $ 3Z,0�0 Will the lot be re-graded? ❑Yes Fm]No Will excess fill be removed from premises? ❑Yes ONo 1 PROPERTY INFORMATION Existing use of property• .� Intended use of property: =c�wr l-1 I - - Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R this property? ❑Yes Bo IF YES, PROVIDE A COPY. Check Box Affer Reading 71ieownec/contractor/design professional is res a -„ ponsible for all'drainage and storm water Issues as provided by ; Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinanceof the TowwofSouthold,Suffolk;County,New Yorkand other applicable Laws,Ordinances or Regulations,for the construction of buildings, -.—r additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws;ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section'210AS Of the New York State Penal Law. Application Submitted By(print name):GreenLogic LLC MAuthorized Agent ❑Owner Signature of Applicant: J A Date STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ` day of YI JUIN ,20 ?� n o P is CASSANDRA L COVELLO Notary Public State of New York NO.OIC06399661 PROPERTY OWNER AUTHORIZATION Qualified in Suffolk County My Commission Expires Oct 28,2023 (Where the applicant is not the owner) Po 66y ( 63 I, Ly i01L-u reslding-at L_C do hereby authorize GreenLogic LLC to apply on my behalf o the Town o South Id Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 �g�}ffCdtk1, BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD - Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 , ,� ,�•� Telephone (631) 765-1802 - FAX (631) 765-9502 ' roaerr southoldtownn .gov -- seand6a�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8/4/2022 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Phone No: 631-771-5152 ®krequest an email copy of Certificate of Compliance Address.: 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Hasday 2020 Family Trust Address: 100 Macdonalds Crossing, Laurel, NY 11948 Cross Street: Phone No.: 917-572-5318 Bldg.Permit#: M30: email: goaliemom17@hotmail.com Tax Map District: 1000 Section: 145 Block: 4 Lot: 15 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (18) SunPower SPR-M415-BLK-H-AC panels Et (18) Enphase IQ7HS (1) SunPower PVS6 monitor System Size: 14.780kW Check All That Apply: Is job ready for inspection?: DYES ❑✓ NO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: DYES [—]NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 ` Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(aDsoutholdtownny gov - seand(aDsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8/4/2022 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Phone No: 631-771-5152 ®krequest an email copy of Certificate of Compliance Address.: . 97.North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Hasday 2020 Family Trust Address: 100 Macdonalds Crossing, Laurel, NY 11948 Cross Street: Phone No.: 917-572-5318 Bldg.Permit#: 0 email: goaliemom17@hotmail.com Tax Map District: 1000 Section: 145 Block: 4 Lot: 15 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (18) SunPower SPR-M415-BLK-H-AC panels Et (18) Enphase IQ7HS (1) SunPower PVS6 monitor System Size: 14.780kW Check All That Apply: Is job ready for inspection?: ❑YES ✓❑NO ❑Rough In ❑✓ Final Do you need a Temp Fertificate?: DYES ONO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 02 ❑H Frame[-]Pole Work done on Service? ❑Y ❑N Additional Information: 1 PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx I 1 iSUFR TOWN OF SOUTIIOLD—BUILDING DEPARTMENT o Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 https•//NNrww.soLitlioldtownnv.gov Floodplain Development Permit Application PROPERTY.iN.F061VIAT10NyA Flood Zone: FIRM Panel: SCTM#1000-145-4.-15 Address: 100 Macdonalds Crossing City:Laurel Zip: 11948 CONTACT PERso'rv : `<<-s Name:GreenLogic LLC - Barbara Casciotta Phone#:631-771-5152 X117 Mailing Address:97 North Sea Road, Southampton, NY 11968 'P�Ro�ECT.oEscRiPTio : Roof mounted solar electric system 14.780kW ECTION:A.STRUCTURAIDEVELOPMENT.(CHECKACLTHAT:APPLY) S, T: �e-ofStiuctuia%'Activit}%;' -. :•. - e. f:Structure. T.. . o Yp, *Residential (1 to 4 families) ❑New structure ❑ Residential (more than 4 families) ❑ Demolition of existing structure j ❑ Combined use ❑ Replacement of existing structure ❑Non-residential ❑ Relocation of existing structure ❑ Elevated ❑ Addition to existing structure ❑ Flood proofed(attach certification) ❑Alteration to existing structure ❑ Manufactured Home ® Other: Solar Panels ❑ Located on individual lot ❑ Located in manufactured home park : . : PPLY`: ELOPMENT. CHECK ALL THAT A B..OTHER DEV T .....,.)'` ' :SECTION { ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging ❑ Connection to public utilities or services ❑ Paving ❑ Placement of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑ Watercourse alteration (attach description) ❑ Excavation (not related to a structured development) ❑ Other development not listed (specify): •_..:r. .. '. :...:: - z; • to t{ie)Zest ofm' knowled'e-fh*e information'c'onfa ned ... Bysigning,below.l 64-terms-an d conditions,of.this,permit and certify. y . g.. in'this application is true and accurate.:.I iiriderstand,that n6 Work may start until a`permit,is"issued:The permif may be'revoked if any false statements are'made hei ein:If revoked,all,work must;cease:until permifiis'reris'sued.Development shah-not be used or`occupied ermit will ex'pi no work is;commen'ced`rivthin;oiie year•,of,is"suanc ,Qtti'er pe�ri�itsmay'be:;:. until.a:Cert:of"Compliance`;is;issued.Thep„ p ., re"wired to:.fuiflll:re""u'lato" :;re"uirenients'.App}icant gives consent to local autfioi ity or rep"resentative to makereasonable inspectiofis;. G g ry 9, to verify complian'ce:; 't s.. Application Submitted By (print name):GreenLoglc LLC Signature of Applicant: Date: 11/7/2022 GREENLOGICO ENERGY August 4, 2022 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Hasday 2020 Family Trust 100 Macdonalds Crossing Laurel, NY 1000-145-4-15 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, `J3avc,=ac ew cw& Barbara Casciotta Account Manager Barbara@Greenlogic.com GREENL 6005 v.rrfejl jic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S. Service Rd., #106 Southampton, NY 11968 Rosyln Heights, NY 11577 GREENLOGIC° ® M ENERGY JAN . .0 2023 ED BUILDING DEPT. 70 nF cnr QLD January 6, 2023 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Project Info: Building Permit No. 48450 Craig Hasday 100 Macdonalds Crossing Laurel, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy after inspection? Please let me know if you have any questions about the installation. Sincerely, 53x1 bauac&-m ao tac Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC •www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 SURVEY OF P/0 LOT 12 & LOTS 13 & 14MAP EDGEMEREFPARK FILE No. 742 FILED JULY 2. 1931 SITUATE Q LAUREL TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-145-04-15 SCALE 1"=20' JANUARY 10, 2008 di` o o AREA= 27.196 eq. ft. ^•�j 91x _ oo p �� (Ta suLKHrAD) 0.624 ac. lb sn lb1p �a 5" '.(�� d"' \.\•'•. '•AD y. i..�;�, o•Rf ago m ., Qk c xm I. 1�1 \xa7 G �1 xm \ \'qt• o. \ N !/ ,N ` u r•lpzo O xm b0. 19. •ate- :�4� 5 by ^//�� m REP.WCO N KiMGV[E WRM 11E IaaAY C mwarac rOR 1111E Sumas A5 601Hf9® Y m nE Lws Ara N•RRam Na ADOPIEQ 14, — ral ea use er Txc xDr laac mac uNa FTb TOTE ASSOONtlN NOTES. u 1. ELEVATIONS ARE REFERENCED TO N.G.V.D. 1929 DATUM EXISTING ELEVATIONS ARE SHOWN THUS:m. P' • EXISTING CONTOUR LINES ARE SHOWN THUS:————s———N .� rn - EEa7 naDR N.Y.S.Ela No.50167 nN. CARA¢FIDOR S rs - 1aP a eaarAD m - 9onaW or 9uuOEAn WWIIO®ALTFWATOM 011 AOOROI BR - BOf1011 Q WNL (] Nathan Taft Cor +f & - Lan d Surveyor —",IRan N�Ma1— " TIE L1xD$UmE1OR9 DA®Sm a9 r �SVL SXNL MOT BE a0115Da✓ID ro a A vuD nEE wPr. fAATG11Ob IA]M'ATro MFIOLH SHNL RUM arar ro TIE PaEal ROR WIEN TME sumo' - TNAa SleTge-962tliona-Site PimW- Can0latlan lOAolrt PxrP,M®.Ala ax hs sawF ro 1xc � mlE mcAMr,mwmanca Amlcr Nm 3 PHONE(671)727-2090 Fax(831)727-1727 m ME Turox mmutl9ra AIE MOt T0.46'faUaE OFFrES LOWED AT AWEDIO ADDRESS Q 322 ROANOKE AVENUE INE c aflmRECORD• :N E O RIpE13 a WAY RNMEAD,Neal Yak 11901 RNnheeOg .ftvB OR&g01-0965 ANO/oR OF If ANY.NOT 6NOWN ARE NOT GOARIM®. w EXISTING SERVICE EMERGENCY AC 120/240, 1PIH, 'W" S!'ANIDBY GENERA:,OR .................................................... KWH ) r PV SA 1 107 AC--COMBiNER a. L.. I INV-1 ......._......_I........._.... ....................I........... A AC-CMB-1 (PV LOADS ONLY) 200A MAIC ...................... 1 OOA 71 L--- INTEGRAL DC/AC DISCONNECT SWITCH, TYP. 1 iGRb-TIE INTEGRAL 4-STRING A 8 LINE TAP DC CIRCUIT COMBINER, TYP. 3KR--1 PV-SA 2 A, INV-2 .',J ,R-14 I KR--2 AC DISCONNECT I f I AC- 1S;-1 "It __F 1 OOA FTT W. BKR L--- �1;: - i i -c/T NEW EQUIPMENT BKR-4 PV-SA-3 Pm-1 ❑ MAIN EJ ES ................. III V V_ SA 4 - L, \ID E171 V I N 2 1 13 EI E3 EGG TVP. PV ARRAY T EXISTING AC PANEL I ; III I EXISTINGi JAN 0 5,202 I, EGC #6 CU Erfl ED L4,J L --------- - IRREVERSIBLE SPLICE, TYP. BUILDINGDE TOWIOr-Q-nir"A NLn Hasday, Craig REVISIONS 100 MacDonald Crossing 04 GREENLOGIC® Laurel, NY 11948 G� ENERGY 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: HSDY-3LD2 Revision: 2 Revised: 12/16/2022 ELECTRICAL LOAD SUMMARY,AC CIRCUITS STATUS TAG POWER, MAX VOLTAGE RANGE MAX.AC VOLTAGE, NOM. CURRENT EXISTING PV-SA-1 3,150 WATTS 211-264 VAC N/A N/A EXISTING PV-SA-2 6,075 WATTS 211-264 VAC N/A N/A EXISTING INV-1 3,000 WATTS 211-264 VAC 15 A AC 240 V,AC EXISTING INV-2 6,000 WATTS 211-264 VAC 25 A AC 240 V,AC NEW PV-SA-3 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC NEW PV-SA-4 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 10 / 6 B THWN-2 3/4" PVC-40 12 / 12 C THWN-2 3/4" PVC-40 10 / 10 D USE-2/PV/UF 3/4" PVC-40 12 / 12 E THWN-2 1-1/2" PVC-40 1 / 6 F THWN-2 1-1/2" PVC-40 1 / 6 G THWN-2 3/4" PVC-40 12 / 12 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM REVISIONSSo na Hasday, Craig ,y 0S 3.Sr {, 100 MacDonald Crossing �h�� °� y E E L®G IC® Laurel, NY 11948 �* ENERGY ' r 2.) AS-BUILT CONFIGURATION 'q °zr�s� a° ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Pa e 3 of 3 Drawing No: HSDY-3LD2 Revision: 2 Revised: 12/16/2022 EXISTING PV EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-225-BLK, 2-STRINGS OF 7-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-225-BLK, 3-STRINGS OF 9-MODULES INV-1 DC/AC INVERTER SUNPOWER SPR-3000M-US INV-2 DC/AC INVERTER SUNPOWER SPR-6000M-US BKR-1 CIRCUIT BREAKER, PV-SA-1 (EXISTING) MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-1 CIRCUIT BREAKER, PV-SA-1 (EXISTING) MATCH AC COMBINER PANEL BRAND, 2-POLE, 30A AC-DSC-1 AC DISCONNECT BEAKER, LINE-TAP 250 100 2-POLE, NEMA-1 AC-CMB-1 AC COMBINER PANEL 250V, 100A, NEMA-1, 1-PH, 3-WIRE NEW PV EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-3 PHOTOVOLTAIC SUB-ARRAY (NEW) SUNPOWER SPR-M415-BLK-AC, 1-CIRCUIT OF 9-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY (NEW) SUNPQWER SPR-M415-BLK-AC, 1-CIRCUIT OF 9-MODULES BKR-3 CIRCUIT BREAKER, PV-SA-3 (NEW) MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-4 CIRCUIT BREAKER, PV-SA-4 (NEW) MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A PROPOSED EQUIPMENT SPECIFICATIONS Hasday, Craig REVISIONS fl 100 MacDonald Crossing E E N LOGIC Laurel, NY 11948 ® ` * ^ ` ENERGY - - r 1.) NSITIALSUBMIITTALWITHAPPLICATION FIGURATIONORNENyO? ELIMINATING THE COST OF ENERGY Page 2 of 3 Drawing No: HSDY-3LD2 Revision: 2 Revised: 12/16/2022 9 11 11! 111 J A M E S J. S TOUT .A R C H I T E C T & Assoc. 2 G REG L ANE E AST NORTHP0RTN. Y. 831 — 8 58 9388 �a Letter of Certification September 26, 2022 I FLOOD ZONE RE: Hasday Residence ;-OMPLY WITH CHAPTER 1146" 100 Macdonalds Crossing 7LOOD DAMAGE PREVENTION Laurel, NY 11948 SOUTHOLD TOWN CODE. To whom it may concern: j �ofYj I4f,(Aj-�kad�'�y' a I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above listed address and have determined the structure and the attachment to be adequate to support the new additional load imposed by the proposed solar system and complies with the 140-mph wind design load as per 2020 Residential code of NYS (RCNYS), 2020 Energy conservation construction code of NYS (ECCCNYS), and the ASCE 7-16. The 2"x 6"@ 16"o.c roof rafters will provide the required support. The existing roof has 1 layer of shingles on 15#building paper on W" plywood sheathing. APPP VED AS NOTED James J.Stout DATE: 2 B.P.# Architect FEE: LO BY:--JQIL— ,)CCUPANCY OR NOTIFY BUILDING DEPARTMENT AT 765-1802 8 Asti 1-1 0 4 PM FOR THE IS c U, IL ,IAI E II FOLLOWING INSPECTIONS: J `+ YY V l� 1. FOUNDATION - TWO REQUIRED T ^ FOR POURED CONCRETE NI TOUT E,RPICAT;. C�N��E-� sTctiiT ROUGH - FRAMING & PLUMBING IF CCU `NCY 'r � F' SULATION 4. NAL - CONSTF;UC-ION MUST _ COMPLETE 0. C NSTRUCTIGN SMALL MEET THE COMPLY WITH ALL CODES O fi ,o R EMENTS OF THE CODES OF NEW NEW ORK TOTE & TOWN COD 0RK STATE. NOT RESPONSIBLE FOR AS E U1RE ND CONDITIONS *OF NE�� ESIGN OR CONSTRUCTION ERRORS. c j 6 I j- L,rI IAC BOARD _� TONJNTRUSTEES ELECTRICAL INSPECTION REQUIRED GREENL®GIC® ENERGY Greenlogic,LLC Approved Hasday,Craig 100 MacDonalds Crossing Laurel,NY 11948 Surface#A: Total System Size:7.470kW 1 circuit of 10 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:220° Pitch:20° Monitoring System: ❑ ❑ ❑ ❑ SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:30'11 1/2"X 13'8 5/8" Surface:43'1"X 17'1" Magic#:Invisimount Legend: ® 18 Sun Power 415W Panels ® SunPower Invisimount Rail • 52 Quick Mount E Lag 8 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: '` EDARC'�i SESJ S To I JLAUG Q - 2072LI BUILDING DEP,' Drawn By:D Drawing#1 of 5 TOWN OF SOUTH Date:07/07/2022 1 REV:A Drawing Scale:3/16"=1.0' GREENL®GIC® ENERGY Green Logic,LLC Approved Hasday,Craig 100 MacDonalds Crossing Laurel,NY 11948 Surface#A: Total System Size:7.470kW 1 circuit of 10 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:220" Pitch:20" Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" ---U6;� Ul Array:30'11 1/2"X 13'8 5/8" Surface:43'1"X 17'1" Magic#:Invisimount Legend: ® 18 SunPower415W Panels ® SunPower Invisimount Rail • 52 Quick Mount E Lag 24"Douglas Fir Rafter 16"G.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ,��RED A% S S . q! pq i r.FLL_ s. �q 163 i0 N E� Drawn By:DF -1115-a cawing#2 of 5 Date:07/07/2022 REV:A Drawing Scale:3/16"=1.0' -&GREENLOGIC® ENERGY GreenLogic,LLC Approved Hasday,Craig 100 MacDonalds Crossing Laurel,NY 11948 Surface#A: Total System Size:7.470kW 1 circuit of 10 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:220° Pitch:20" Monitoring System: ❑ ❑ SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount 1 Panel:73.7"X 40.6" Array:30'11 1/2"X 13'8 5/8" Surface:43'1"X 17'1" Magic#:Invisimount Legend: 1 ® 18 SunPower 415W Panels ® SunPower Invisimount Rail • 52 Quick Mount E Lag 2 8 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 2 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: .� GRED Apc S j Sro y% T 021 r N E� Drawn By:DF Drawing#3 of 5 Date:07/07/2022 REV:A Drawing Scale:3/16"=1.0' �� q\ -��. 'L� '�.-..• z _:,+o No Vent Pipes Will Be Covered By The Solar ArrayG�GREENL®GIC° ENERGY Legend: GreenLogic,LLC Approved Hasday,Craig AR-Access Roof AP-Access pathway,36" minimum width SVO—Setback at ridge 100 MacDonalds Crossing per R202 definitions per R324.6.1 as per R324.6.2.1 Laurel,NY 11948 Total System Size:7.470kW 1 circuit of 10 on a 20A breaker 1 circuit of 8 on a 20A breaker I I Azimuth:220° Monitoring System: SunPower Panel/Array Specifications: t Panel:SPR-M415-BLK-H-AC t Racking:SunPower Invisimount 0 t Panel:73.7"X 40.6" t Magic#.Invisimount O - _ Legend: Meter _ I ; ® 18 Sun Power 415W Panels SunPower Invisimount Rail • 52 Quick Mount E Lag "t " ,l B B 2x6"Douglas Fir Rafter 16"O.C. Notes: gyn ;_,i r. Number of Roof Layers:1 L.__ ��o Existing Array [�— �-p ———-L} -� Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.31 psf = Engineer/Architect Seal: J 18 SunPower 415W Panels \ NE`N Drawn By:DF '11Drawing#4 of 5 Date:07/07/2022 1REV:A Drawing Scale:1/16"= 1.0' -G�GREENL®GIC® ENERGY Green Logic,LLC Approved Hasday,Craig 100 MacDonalds Crossing Laurel,NY 11948 Total System Size:7.470kW 1 circuit of 10 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:220° 10B MATERIAL LIST Monitoring System: -- SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6^ • Magic#:Invisimount Material List tai. Rail Material List W.. Legend: ® 18 SunPower 415W Panels ® SunPower Invisimount Rail Cast Aluminum Mounting Block w/Black Aluminum Flashing 52 • 52 Quids Mount ELag 5/16"x7/9'EPDMSeal ing Plug - 52 - - --- - Douglas Rafter 16"O.C. 2 6" Fir 5/16"65"Hex-Head Lag Screw 52 Notes: - -- — Number of Roof Layers.1 5/16„x1.25„FenderWasher 52 j Height above Roof surface:4” Materials Used:Quids Mount,SunPower e o 0 e Added Roof ad o I f PV System:2.31 psf Engineer/Architect Seal: — - _ TCG �- a� 1 92 633 �0� F N ON Drawn By:D _ Drawing#5 of 5 Date:07/07/2022 REV:A Drawing Scale:1/16"=1.0' SUNP WE R° 425-410 W Residential Black AC Module SunPower"Maxeon"Technology Built specifically for use with the SunPower EquinoxO' system,the only fully integrated solution designed, engineered, and warranted by one company. Highest Power Density Available The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest-efficiency all-black AC solar module available? Part of the SunPower. I ° Equinox' Solar System .. E _ Seamless aesthetics large ®Compatible with mySunPower monitoring. f_ . } F U jHighest Lifetime Energy and Savings . kirjF_;�.tDesigned to deliver 60% more energy over 25 years in " real-world conditions like partial shade and high temperatures.2 , _ =es ... .... .... .... _.. ..... ._. .... _ ... Factory-integrated," IDL Upto Microinverter /�^ V J''. iv1b., r A Highest-power integrated AC module in solar •Engineered and calibrated. by SunPower for SunPower % Years of C;perntion AC modules Best Reliability,Best Warranty With more than 42.6 million and 15 GW of modules deployed around the world, SunPower technology is proven to last.That's why we stand behind our module and microinverter with the industry's best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar. s. M425-BLK M415-BLK ( M410-BLK SunPower Residential Black AC Module Inverter Model:Type H(Enphase IQ7HS) @240 VAC @208 VAC Max.Continuous Output Power(VA) 384 369 _.-.._.._................................._.._........._ -........_....................._.---- Nom.(L-L)Voltage/Range'(,) 240/211 '7.64 208,1183-229 Max.Continuous Output Current(A) 1.60 1.77 Max.Units per 20 A(L-L)Branch Circuit'! 10 9 CEC Weighted Efficency 97.096 J 96.5% Nom.Frequency 60 Hz 60 Hz Extended Frequel Range 47-68 Hz 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A 4.82 A - ... .._...-........ ......_..._.._............- -- -- Overvoltage Class AC Port III III AC Port Backfeed Current 18 mA 18 mA Power Factor Setting 1.0 1.0 Power Factor(adjustable) 0.85(inductive)/0.85(capacitive) 0 85(inductive)/0.85(capacitive) •s 0. ® e o SPR-M425-BLK-H-AC SPR-M415-BLK-H-AC SPR-M410-BLK-H-AC ••25-year limited power Warranb,< Warran:l Nom.Power(Pnom)W'•! 425 415 410 es 25-year limited product 1,varranty - Power Tolerance +5/-01/0 +5/-0% +5/-0% UL'174'I/IEEE-1547 UL 1741 AC Module Module Efficiency 22.090 21.S% 21.2% UL 61730(Type 2 fire rated) Temp.Coef.(Power) -0.29%,'°C -0.2995/°C -0.29%/°C UL 62109-1/IEC 62109-2 -- - FCC Part 15 Class B Shade Tolerance Integrated module-level max.power point tracking ICES-0003 Class B CAN/CSA-C22.2 NO.107.1-01 CA Rule 21(UI.1741 SA)s Certfications (includes Vol(Nar and Reactive Power Priority) I UL Listed PV Rapid Shutdown Equip Operating Temp. and ment' --- ---- I Compliar:ce Enables installation in accordance with Max.Ambient Temp. 122°F(50°C) NEC 690.6(AC module) Max.Test Load' Wind:12.5 psf,6000 Pa,611 kg/rn2 back NEC 690.12 Rapid Shutdown(ins:de and outside the Snow:187 psf,9000 Pa,917 kg/m2 front array) Wind 75 psf,3600 Pa,367 kg/m2 bath NEC 690.15 AC Connectors,690.3YA)-(E)(i) Max.Design Load Snow:125 psf,5400 Pa,550 kg/m2 front When used with AC module Q Cables and accessories: Impact Resistance I inch(25 mm)diameter hail at 52 mph(2.3 m/s) (UL 6703 and UL 2238), Rated for load break disconnect ®. PID Test 1000 V:IEC 62804 Solar Cells 66 Maxeon Gen 6 Front:Glass I sigh-transmission tempered glass with anti-reflective coating Environmental Ratin- Outdoor rated j Modules per pallet 25 i ....-------............................_........ --._..._.._. Frame Class 1 back anodized(highest A\F 1A rating) i Packaging box dimensions 75.4 x 42 2 x 48 0 in.(19!5 x 1072 x 1220 mm) Weight 48 lbs(21.8 kg) Pallet gross weight 1300 Ib(590 kg) Recommended Max. Pallets per container 32 Module Soacing 1.3:n.(33 chin) Net weight per container 18,880 kg 73.7 in t Based on datasheet review of'websites of top 20 manufacturers per INS,as of July 2021. + (18,2 ril- FRAME PROFILE 2 Maxeon 435 W,22 545 efficient,compared to a Conventional Panel on same-saed arrays(300W i 945 efficient, approx.1.6 m2),7.9%more energy per watt(based on PVSys[pan hies for avg.US climate).0 Silt/yr slower degradation rate(Jordan,et.al."Robust PV Degradation Methodology and Apo icadon"PVSC 2018). Groundin les 3 Based on search of datasheet values from n:ebsites of top 10 manufactures per IHS,as efjune 2021. 4 Limits may vary.Refer to local require!nents to define the rUrnber of m croinverters per branch in your area. .. Y ».......A. 5 Factoryset to!EEE 1547@-20'4 default settings.CA Rule 2.1 default settings prof le set during commissioning. ,o N 6 Standard*1 est Conditions(1000 W/m=irradiance,AM 1.5,25'C).NI DC•;oltage s fully contained within the module. ' ma "" 7 UL listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12.and C22.i-20!5 Rule 64-218 Racid (Aj Long Side:1.3 in(32 rpm) Shutdown of PV Systems,for AC and DC conductors,vvhen installeo acco,ding to manufacturer's instructions. 51-ort Side:0.9 in(24mm) E Please read the safer,,and installation instructions for more information:regarding load ratings and mounting configurations. t I See v✓masunpowermmicompany for more reference information. Please read the safety and installation instructors for deta:is For more details,see extended datasheet'vaaw.sunpewer.rpm/solar-resources. Specifications included in this datasheet are subject to change without notice. coeeue vrxi°:ury 02022 SunPower Corporation.A.I rights reserved.SUNPOWER,the SUNPOWER bgo and EQUINOX are 544400 RevA registered trademarks of SunPower Corporation in the U.S.MAXEON is a registered trzdemark of Maxeon Solar LISTED ea�euo Technologies,Ltd.For more information visit wana•.rnaxeon.o?rnAegal. M.&Ii e,�r°,r°, -Type 2 January 2022 i'�s 13 CCMM p;g ,fin ,e:�� "f•� �w Simple and Fast lnstallatio _..... lrteg-O 'ied module-To-rail ground ng Pre-„ssQ:ml�lerl mid arir..end c'arnras Lev!ating rnld camp,for eases)placernent ? i 03 :O! 5"�:,aW^'�+.'l�,.s,::....r-xte.. e»�`ka'...•"'',N ` Mid:-1a?'" ii• I'JG';.l �r"1;"IIIi.r,IF.S i,:�n,iil .lt,el, .l �w:x"="��=^-^ �`•'� ,�.,_ •,� Simple,p,e-('rill,.,d ail s,-lkx, 21 o.'Listed:ni.eg ralod gr(x.rn,r4 FIeXIbI(-_y Design Addresses - Addresses netarly all slope res:clerciai roofs t<. g«. • Design it landscape and porl.,ai F:o!i5 t'?ct:le es31)i 0;:)Stacl(2 nianagerren. a.R Customer..T referred Aesthetics . module and t-" mounting aesthetics E�est it class system aesthetics Elegant Sime-)licity Premium ovv-profile design SunPoweOl InvisillountT”. is a SunPower-designed ned Rack anodized components g Hidden and clamps and end camps rail-based mot.anting sysr.en The InvisiMOt.ant system and capped,flush rails add7"P..S ses 'eSIdP..ntla' sloped roori5 c'a^d COmi;inPS 'c35te Part of Superior System , ., -' Instaliatc_in tin�acl, desa: ra flexibility, grad st.aperior aesthetics. B�?ilt ror use with Sunr)o'o er 17C and AC modules (I"7 E' Ir1VISIMt1t.Jnt: produci:was specifically envisioned Land fest-in-class s ,�ysrerelianility and ap sthenic .'Omoine w:t l`unPotler modules,and engineered to pair-with SunPower C-f1ocl les. The resulting monitorirg app. systern-level approach will arnplify the aesthetic and installation benefits for beth homeowners and installers. Ufa. .. �....£.. ;.� sunpower.com NADH 90S60S#]ua ujmoQ ai:Ju:imp: z)3, cigrs as rausE»vp s!qi ui p,pnjlul suoi;ekuc+ac,s UJp:".l&',•>.(;ilii!i; '1 Wo:dO�A;Jdd>aa alatjk Iq n„,..�iW!J v_p ai:?S,{JO�ilai)L'a»ac)�ko iN 't[.iyBailLJJ.,:J JE„ne<j:;n;;j0 skaJ'w:njir!k t)miJ'Sii?JJ io Sk;BW��✓YJt d.2.1(�.;it)�i51ARiµae a3o1 t1�:r:�.J_hl€S- •?'._,.t,;c�i'Jtls 'Pv<�.�_sa�sluai;;ilt�! 'urikeaod€u;;aornouu:�s<:;u .� '�;jjjge;odo.,o;m<,;;;y;,,Atj J':;<.o gnk.=a. kunoj jfs!.+.ui ............................................--'-....._................_.._.............._.................._....................................................................._....._..._.............._...._............_................ ,......._..............................._.._.._..........._......_......__.._....... _........................ .bre uauJ.^:,c; s•Jl.i'i'7f_inuPUJ ^rhn;>Je Juaulll7 iJ£'joo;CJ.f. b;i lFfnl.af.74.-tri co f at,E{_i;JO,c)eJA@j:.q les:an;:u[1 1i.IdU.IU)[J7G/!')Q:_J 01: ]F>,_puP 17<3).Adl } :,oz;• yr, tt, :ePa^; l;Onc.ill:iCl\f '''..v s pas».dj4 w• t9 m:� t"li�t3 w :::3:•' '_' iU,3u fl.)L'7JN`�',:i�l',;)n:J r)n�,'sln1 i:UC ��:.:. :�s.a;�`,t:t�.,...�,.k: l^•k $...Car, i4”^�§�triQ'xu�url:•.aef`g: ,:.,.^„ au. =iJJ :elN Jc a gU:U:GGI' llCi�' --......._.......-...................._..........__........._................................. .. ! �...... ...H:k.Em..::e;' m:,. ,��yq�€�wlt•)�', °a s'.°5�;�'e?�sffi,r��;I�.�Ay., ..._ ._,,,.�. a_ c'ic b SSE';' ...e...,+^'.:,�aa•:.:...., <: j�•,ssy;.e�,��t;�iw'w•..., tq�x�y .pry) � °da,"��'A,,"�'t�,���. .l:d•�r.��` d� ^.:::...•^ A� ", K«�� .. w>h��w��.:�.`��,.?a'= ............................ ....... .................. ..._....................... , (�` r_'U.`•t U I .auafpJdoo iU•1Od)Ici,) -wlsl dc*.)pua .......................-_ . ..................- ._........._..._.._ .._.._ :lJUF.0 e;•:\';x;11) ".r .._f,'i)�v.s•) 1!%i's j`)0 { aea ....c_... ..... .. Fsn :hJ�.o,a Je'd-'_q.:I I i}�-CN) 410€.k:ass', x Jenn'i npr;a;i 1n ;<SZ (aJ, o C;).,(;;'0>:' S! SCC9;n;If,eunup.0€qti+ a.-colas Ilei . w, {I )!)l9 IIF' �, ....................__...._..... , JLI c'LcCGS,x611P uu;uju:r?Ie l(,r,:;.> ........................-...._. _...........__................................. ......... ................... .................................:.-— — --- ...-........... ......... ... _. nb 'r"�z`a 1,0 l`;I�y-:,sar STOW!S a;;!�o r:;E>,3... auJ;l_)..PIIrV a_ac.J!rr,olJ e,. ()r)r)r' ,` -.-................'.".....................................:...... lJidr:E,; UJB 1,P -; - ---- -- ............... _...._-....__ .. nl a;;a• IPua'Jei^•! tuauocl:u0,) J: cl e)7: G'1>-) OEi o; .!it o nJP..ol.ua.1. :>1.:�> ..N•�� ira r:• :�A:. ..:z: �'i ga,. .:::?•.: .ecce.:. � "•.ui'Ncc^s.• .,g z�'i�r` :y'r•1��:^a^fes _� � __s••�...�,.�„ �';z �.�.��? �._.^_;tj_•?:,,.�".�17i�"��€,�;I�t '�?'�s';�t„ =.?r.it:= :. ii�"?�<.,., 's �a �.,€�r� �'i.:(>_ ;"y,y,�;,.:G"��.r;,i . t•tn . ..<c a '•.. •.<g<..:...... .. . .�....:.x..n.:a.a a••t�•.� tr a:: .,�.,_a... C12)Pu'_J Algw,asssy-arl p:;nbr; a:qJ5 i'211:11�;le;. UJJcI 1 UU"i Gale'.P! J o ,.,.......<o......____,__ ......_.._._.- ...._... .. ........._.(�a^.,.•,.•,.i �i'9 U;1W ^.Bf�tiuoN!��}�€111';N nii r , I e c . 4, L.:.: _ I:^21 Pu : II�p(3 i x.c ln,, j qlP::e dtuel.]P4N?ftil-11001,14 WOWC M, No , AMR e � � r�?,. •�t� wr;t',:., yiryi•'k'r.°l•'<K'.'r,.::...•. ;A. :•tea 5:•3...,, .. •m3e .< ...:mow.,,,,,,a....... .......h,,..,,.....,.,,.....,<...aCe�sY.......,we ,,..-.x....,..; A,.,.....�.,.......... .....Y,...w....k.m��,....,,»�..�......iXd:,Y,..a:..wrxdm,.Ma. ....,< e .. L , -4r•. 'tea°:w- Y "^ ... <.:•x_=e:�`YLa zz ""�;.<;: sT--�„.a. w�.•,, sd � 9,'✓' ... .. s. p.RRt nrc+h` '. •e -". �� � if, e Improve Support, Reduce Maintenance Costs SunPo?wer Energyl-ink—Plug-and-Play Installation An int,uitve monitoringvtebsilLe enaglcs you to: This COr7?pl-te SOIIai70n for re5usentiai and conTrneraal mon:'-orr'g and See it visual rnaip Of CL:sc.or'mer slteb control incU.de,. 'te uF'cv,, r":ti 'v S;..11:t-rysor-6(PbS{.'))which improves �ernctel'v rna age hunch eds o}sK'es L'ie installadon process,Overall system reliability,and CUStornC"1' iE C,lve elecdve System reports E'XpE'r'i-r'IC( L.oCiitE Sys tT1(S5 10' ct"d reryiol-ely(lad;r':Usk Cornpac-t 0otprint for improved aesLheLics Diagnose issues or`.ine Robust.Cloud CE nnecti icy and cort'prehensive laical tonne;rlvirV Drill dovvni for the status(:)` nd viduai device; Flexible configuration of devices during Installation „.#r ,•. ,Ay, consumption metering M_ R-venE.i--graoe produc?:Ion!net:-ring(pending) Web-based commissioning Remote diagnostics of FVS6 an,,]inverters Durable UL Type^R Enclosure reduces maintenance dosis e r "f Easy Integration with SunPower eBOS Add Value for Customers Robust Cloud Connectivity With the SunPci',.•ver M niton ing System customers can: h:'iE.;lt.iple options to rnaintain optirnal See what their solar s'ystern produces each connectivity: day,month,or year Hardwires Ethernet Or�urnize,heir solar nvestryierill and save or? Wi-Fi energy expenses ` i) Cellular backup See their ene- use and estimated bill savings See their solar EvsterT's peforrnance using the Sunf,o-wer rnonitoring v.rebsite or mobile app ij ; ;y 141 LL aq. &„R L- kt eq ny :• x I 7 •� i 5 SunPower Monitoring Websites PVSri SunPower AC Modules .'IIH 1111 t1 A� 0�lI1 W� �I " i � ]� •I gyp[ �.... •>•. w° Multiple communication options include Ethernet,Wi-Fi,and cellular. .. - t?M xr •'' � ' � to � '�,. �i �€> �=,zm:.. ?',�:'_ _ �,sy.. �$ 4�.a a�::T7;::.y�.,�;a G�`/7. Number of SunPower AC rnodules 85 Temperature -221T to {1»G°F{-30°C[o+-60°C supported per Fi'Sfi F'lumrdrty(maximum) 95%,nor-conbensin; Intr:.rret access High-speed internet accessva accessible router or switch • 100-240 VAC:.(i..-N),50 or 60 F3z • _08 JAS(L-L I.t 33-phase,,. 60 ht •,,. .,,; �,.�,� r; RS-/-5 inverters and meters . One channel of revenue-grade production rnetering v:.v.' _ ,..3..f.:f::a.ax.•..,�e'.'�,;....., #+„��-:.", s„��=� :5:' �..�:. la,R;,Afi�r.:�.-.��:,�'„r` to. o- � integrated v • E`sRochanr�isOfCOnS!rtinnTet?Yins Weight g V theniet LAN,or opt!onal`IVAN)port Dimensions .1.8 x 8,0 x 4.2 in.(30.5 x 2.0.5 x 10.8 crn) PLC PLC for SunPower AC rnoduies Enclosure rating UL50E Type 3P, VJi-Fi 802,11 big/n 2.4 GHz and 5 GHz _...._.._........................-....._.................._.............................................,::_..._............................. .----...__. Cellular LTF..Ca,..^v 1/:3(:,t!M IS Data. rata Storage oL'days Customer site rrtr rito_.us si�rr��n r�arn _.........--'--'--........._...----..._......................_...._.._.._....--.................... _..__.....__.........................---- - c -- ;lpgrade;; A;�orr1atic tirrnvrare ur)gra;e�; Partner site Pj"Smgrntus sunoow.er.com 3ro:rsers Firefox,Safari,and Chrome Mr,obile devices iPhone'-,iPad1%,and Ai idroio'”, Customer app :o ' (,, '.,..m:P' M 1.Create accoun r::ine at:monitor s.sunTr r.e corn. (" . :.w 2X ,'e 0111 n it `as 2.On a moble clevice,:iownload ri re:SunPower Monitor' ? `vJarranty V a 10 year Limited Warranty app from Apple App Stores"or Google Playlstore. 3.Sign in usir:g account email and password. Certifications UL,WL,CE,UL 61010-1 and-2.FCC Fart 1 i{Class i3) C u` us LMTM FCC ID:YAW529027 E503346 p� e